WorldWideScience

Sample records for ct-guided percutaneous drainage

  1. CT-guided percutaneous aspiration and drainage of postoperative abdominal fluid collections

    International Nuclear Information System (INIS)

    Marano, I.; Mainenti, P.P.; Selva, G.; Cannavale, M.; Sodano, A.

    1999-01-01

    The authors report the personal techniques and the results of CT-guided percutaneous drainage of postoperative abdominal fluid collections. CT-guided percutaneous drainage offers many advantages over surgery: it is less invasive, can be repeated and requires no anesthesia, there are not surgery-related risks and lower morbidity and mortality rates. Moreover, subsequent hospitalization is shorter and costs are consequently reduced. The authors conclude that CT-guided percutaneous drainage is the method of choice in the treatment of postoperative abdominal fluid collections [it

  2. Therapeutic impact of CT-guided percutaneous catheter drainage in treatment of deep tissue abscesses

    International Nuclear Information System (INIS)

    Asai, Nobuhiro; Ohkuni, Yoshihiro; Kaneko, Norihiro; Aoshima, Masahiro; Yamazaki, Ikuo; Kawamura, Yasutaka

    2013-01-01

    Combination therapy of CT-guided percutaneous drainage and antibiotics is the first-line treatment for abscesses. Its effectiveness has been demonstrated. However, the therapeutic impact of this procedure for infection treatment has never been reported. We retrospectively analyzed all 47 patients who received CT-guided percutaneous drainage for infection treatment. Patients' characteristics, pathogens isolated, antibiotics administered, technical and clinical outcomes, complications related to this procedure and therapeutic impacts were investigated. Patients were 26 males and 21 females. The mean age was 63.5 years (±18.7). The diseases targeted were 19 retroperitoneal abscesses, 18 intraabdominal abscesses, three pelvic abscesses, and seven others. As for technical outcomes, all of the 54 procedures (100%) were successful. As for clinical outcomes, 44 (93.6%) were cured and three patients (6.4%) died. No complications related to this procedure were found in this study. A total of 42 patients (88%) had a change in the management of their infection as a result of CT-guided percutaneous drainage, such as selection and discontinuation of antibiotics. In conclusion, CT-guided percutaneous drainage is a safe and favorable procedure in the treatment of deep tissue abscesses. Therapeutic impact of these procedures helped physicians make a rational decision for antibiotics selection. (author)

  3. Therapeutic impact of CT-guided percutaneous catheter drainage in treatment of deep tissue abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Asai, Nobuhiro; Ohkuni, Yoshihiro; Kaneko, Norihiro; Aoshima, Masahiro; Yamazaki, Ikuo; Kawamura, Yasutaka, E-mail: nobuhiro0204@hotmail.com [Kameda Medical Center, Chiba (Japan)

    2013-03-15

    Combination therapy of CT-guided percutaneous drainage and antibiotics is the first-line treatment for abscesses. Its effectiveness has been demonstrated. However, the therapeutic impact of this procedure for infection treatment has never been reported. We retrospectively analyzed all 47 patients who received CT-guided percutaneous drainage for infection treatment. Patients' characteristics, pathogens isolated, antibiotics administered, technical and clinical outcomes, complications related to this procedure and therapeutic impacts were investigated. Patients were 26 males and 21 females. The mean age was 63.5 years ({+-}18.7). The diseases targeted were 19 retroperitoneal abscesses, 18 intraabdominal abscesses, three pelvic abscesses, and seven others. As for technical outcomes, all of the 54 procedures (100%) were successful. As for clinical outcomes, 44 (93.6%) were cured and three patients (6.4%) died. No complications related to this procedure were found in this study. A total of 42 patients (88%) had a change in the management of their infection as a result of CT-guided percutaneous drainage, such as selection and discontinuation of antibiotics. In conclusion, CT-guided percutaneous drainage is a safe and favorable procedure in the treatment of deep tissue abscesses. Therapeutic impact of these procedures helped physicians make a rational decision for antibiotics selection. (author)

  4. CT-guided percutaneous treatment of solitary pyogenic splenic abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Pombo, F. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Suarez, I. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Marini, M. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Arrojo, L. [Dept. of Radiology, Hospital Juan Canalejo, La Coruna (Spain); Echaniz, A. [Dept. of Internal Medicine, Hospital Juan Canalejo, La Coruna (Spain)

    1991-08-01

    Six patients with solitary pyogenic splenic abscesses treated by CT-guided percutaneous drainage (by catheter or needle), are presented. There were 3 unilocular, purely intrasplenic abscesses and 3 complex lesions with loculations and perisplenic involvement. Percutaneous drainage and intravenous antibiotics were curative in 4 patients. In the other 2, who had multiloculated abscesses, despite initially successful drainage, splenectomy was performed because of intractable left upper quadrant pain in one case and persistent fever and drainage of pus after 30 days in the other. These patients also developed large, sterile left pleural effusions. Solitary pyogenic splenic abscesses - particularly if uniloculated - can be effectively treated by CT-guided percutaneous drainage. (orig.)

  5. The role of CT-guided percutaneous drainage of loculated air collections: an institutional experience.

    Science.gov (United States)

    Patel, Bhavik N; Morgan, Madeline; Tyler, Douglas; Paulson, Erik; Jaffe, Tracy A

    2015-10-01

    The purpose of this study is to describe our experience with the role of CT-guided percutaneous drainage of loculated intra-abdominal collections consisting entirely of gas. An IRB-approved retrospective study analyzing patients with air-only intra-abdominal collections over an 8-year period was undertaken. Seven patients referred for percutaneous drainage were included. Size of collections, subsequent development of fluid, and microbiological yield were determined. Clinical outcome was also analyzed. Out of 2835 patients referred for percutaneous drainage between 2004 and 2012, seven patients (5M, 2F; average age 63, range 54-85) met criteria for inclusion with CT showing air-only collections. Percutaneous drain placement (five 8 Fr, one 10 Fr, and one 12 Fr) using Seldinger technique was performed. Four patients (57%) had recently undergone surgery (2 Whipple, 1 colectomy, 1 hepatic resection) while two (29%) had a remote surgery (1 abdominoperineal resection, 1 sigmoidectomy). Despite the lack of detectable fluid on the original CT, 6 patients (86%) had air and fluid aspirated at drainage, 5 (83%) of the aspirates developed positive microbacterial cultures. Four patients (57%) presented with fever at the time of the initial scan, all of whom had positive cultures from aspirated fluid. Four patients (57%) had leukocytosis, all of whom had positive cultures from aspirated fluid. Although relatively rare in occurrence, patients with air-only intra-abdominal collections with signs of infection should be considered for percutaneous management similar to that of conventional infected fluid collections. Although fluid is not visible on CT, these collections can produce fluid that contains organisms.

  6. CT guided transthoracic catheter drainage of intrapulmonary abscess.

    Science.gov (United States)

    Yunus, Mahira

    2009-10-01

    To determine the efficacy of CT- guided transthoracic catheter drainage of intrapulmonary abscess considering success rate versus complications. This prospective study was carried out at radiology department of Al-Noor Specialist Hospital, Makkah, Saudi Arabia, from 1.1.2003 to 31.12.2005. Nineteen patients were selected for CT guided percutaneous drainage. Under CT guidance catheter placement was carried out using Seldinger technique. Nineteen patients with lung abscess were selected for the percutaneous CT guided drainage. Eight (42.105%) patients encountered no complications and lung abscess completely resolved with no residual cavity. Five (26.31%) patients developed pneumothorax, which was the most common complication of this study. These patients were kept under observation and followed-up by chest X-rays. Three (15.78%) had mild pneumothorax, which resolved and needed no further management, while two (10.52%) patients developed moderate pneumothorax and chest tube was inserted. Two (10.52%) patients developed mild haemoptysis which resolved within two hours, hence, no further management was required. Two (10.52%) patients had residual cavity and surgery was performed. Congenital cystic adenomatoid malformation (CCAM) was found in both cases. Two patients out of nineteen patients (10.52%) developed bronchopleural fistula and were operated. No mortality occurred during or after the procedure. CT allows optimal placement of catheter and hence enables safe and effective percutaneous evacuation of lung abscess. The morbidity and mortality of patients with percutaneous catheter drainage is lower than with surgical resection. Hence, CT guided drainage should be considered the first therapeutic choice in most patients of lung abscess who do not respond to medical therapy.

  7. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique

    OpenAIRE

    Bharat R Dave; Ranganatha Babu Kurupati; Dipak Shah; Devanand Degulamadi; Nitu Borgohain; Ajay Krishnan

    2014-01-01

    Background: Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems...

  8. CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

    International Nuclear Information System (INIS)

    Kelogrigoris, M.; Sotiropoulou, E.; Stathopoulos, K.; Georgiadou, V.; Philippousis, P.; Thanos, L.

    2011-01-01

    This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26–52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

  9. Percutaneous catheter drainage of pancreatic pseudocysts

    International Nuclear Information System (INIS)

    Karnel, F.; Gebauer, A.; Jantsch, H.; Prayer, L.; Schurawitzki, H.; Feil, W.

    1991-01-01

    The results of CT/US-guided percutaneous drainage in 35 patients with pancreatic pseudocysts are reported. 27 patients recovered without surgery and no further treatment was required. 8 patients required a subsequent surgery due to recurrence. The role of CT/US-guided percutaneous drainage in pancreatic pseudocysts as well as an analysis of the technical aspects associated with a successful procedure are discussed. Although US may be used, we believe CT is safer and allows more precise localisation and guidance in the treatment of pseudocysts. (orig.) [de

  10. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique.

    Science.gov (United States)

    Dave, Bharat R; Kurupati, Ranganatha Babu; Shah, Dipak; Degulamadi, Devanand; Borgohain, Nitu; Krishnan, Ajay

    2014-01-01

    Percutaneous aspiration of abscesses under ultrasonography (USG) and computer tomography (CT) scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD) has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was drainage and ODI (Oswestry Disability Index) score at 2 years. PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts (n = 2), persistent discharge (n = 1) for 2 weeks, blocked catheter (n = 2) and catheter pull out (n = 1) occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  11. Outcome of percutaneous continuous drainage of psoas abscess: A clinically guided technique

    Directory of Open Access Journals (Sweden)

    Bharat R Dave

    2014-01-01

    Full Text Available Background: Percutaneous aspiration of abscesses under ultrasonography (USG and computer tomography (CT scan has been well described. With recurrence rate reported as high as 66%. The open drainage and percutaneous continuous drainage (PCD has reduced the recurrence rate. The disadvantage of PCD under CT is radiation hazard and problems of asepsis. Hence a technique of clinically guided percutaneous continuous drainage of the psoas abscess without real-time imaging overcomes these problems. We describe clinically guided PCD of psoas abscess and its outcome. Materials and Methods: Twenty-nine patients with dorsolumbar spondylodiscitis without gross neural deficit with psoas abscess of size >5 cm were selected for PCD. It was done as a day care procedure under local anesthesia. Sequentially, aspiration followed by guide pin-guided trocar and catheter insertion was done without image guidance. Culture sensitivity was done and chemotherapy initiated and catheter kept till the drainage was <10 ml for 48 hours. Outcome assessment was done with relief of pain, successful abscess drainage and ODI (Oswestry Disability Index score at 2 years. Results: PCD was successful in all cases. Back and radicular pain improved in all cases. Average procedure time was 24.30 minutes, drain output was 234.40 ml, and the drainage duration was 7.90 days. One patient required surgical stabilisation due to progression of the spondylodiscitis resulting in instability inspite of successful drainage of abscess. Problems with the procedure were noticed in six patients. Multiple attempts ( n = 2, persistent discharge ( n = 1 for 2 weeks, blocked catheter ( n = 2 and catheter pull out ( n = 1 occurred with no effect on the outcome. The average ODI score improved from 62.47 to 5.51 at 2 years. Conclusions: Clinically guided PCD is an efficient, safe and easy procedure in drainage of psoas abscess.

  12. Percutaneous CT-guided interventional procedures in musculoskeletal system (our experience)

    Energy Technology Data Exchange (ETDEWEB)

    Thanos, Loukas E-mail: loutharad@yahoo.com; Mylona, Sophia; Kalioras, Vasilios; Pomoni, Maria; Batakis, Nikolaos

    2004-06-01

    Percutaneous interventional procedures include a broad spectrum of minimal invasive techniques, which are a useful diagnostic and therapeutic tool. In this study we present our experience in CT-guided percutaneous musculoskeletal biopsies, drainages of musculoskeletal abscesses, facet and sacroiliac joint injection and radiofrequency thermal ablation of painful metastases or osteoid osteomas.

  13. Percutaneous catheter drainage of pancreatic pseudocysts. Perkutane Katheterdrainage von Pankreaspseudozysten

    Energy Technology Data Exchange (ETDEWEB)

    Karnel, F.; Gebauer, A.; Jantsch, H.; Prayer, L.; Schurawitzki, H. (Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria) Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Feil, W. (1. Chirurgische Universitaetsklinik, Vienna (Austria))

    1991-09-01

    The results of CT/US-guided percutaneous drainage in 35 patients with pancreatic pseudocysts are reported. 27 patients recovered without surgery and no further treatment was required. 8 patients required a subsequent surgery due to recurrence. The role of CT/US-guided percutaneous drainage in pancreatic pseudocysts as well as an analysis of the technical aspects associated with a successful procedure are discussed. Although US may be used, we believe CT is safer and allows more precise localisation and guidance in the treatment of pseudocysts. (orig.).

  14. Ultrasound-guided percutaneous transhepatic biliary drainage: Experiences in 146 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jai Keun [Sohwa Children' s Hospital, Seoul(Korea, Republic of); Yu, Jeong Sik; Kim, Ki Whang; Chung, Soo Yoon; Jeong, Mi Gyoung [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Deuk Lin; Kwon, Gui Hyang; Lee, Hae Kyung [Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    1999-03-15

    Percutaneous biliary drainage is an important technique for palliative therapy of obstructive biliary disease and diagnostic information. The purpose of this study is to review and evaluate the experiences of ultrasound-guided percutaneous transhepatic biliary drainage. Ultrasound-guided percutaneous transhepatic biliary drainage was performed on 146 occasions in 134 patients. The causes of biliary obstruction were: benign diseases (19 cases, 14.2%) such as bile duct stones or stricture, cholangiocarcinoma (37 cases, 27.6%), pancreatic carcinoma (35 cases, 26.1%), metastasis (22 cases, 16.5%), gall bladder cancer (14 cases, 10.4%), ampulla of Vater cancer (4 cases, 3.0%), hepatocellular carcinoma (3 cases, 2.2%). Retrospectively reviewing medical records, we found out frequency of external or external/internal biliary drainages, puncture of left or right hepatic duct, and presence of bileinfection. Ultrasound-guided percutaneous transhepatic biliary drainage was compared with conventional biliary drainage of previous reports on the basis of frequency of complications. External (124 procedures, 84.9%) and external/internal biliary drainage (22 procedures, 15.1%) were carried out by puncture of dilated right (59.6%) or left (40.4%) intrahepatic duct. Sixty-nine complications occurred in 47 patients. Catheter related complications (33/69, 47.8%) were most common: catheter dislodgement (17/69, 24.6%), malfunction (9/69, 13.1%), leakage (7/69, 10.1%). Other minor complications such as simple fever (16/69, 23.2%), cholangitis (7/69, 10.1%), hemobilia (4/69, 5.8%), biloma (2/69, 2.9%) and wound infection (1/69, 1.5%) occurred. Major complications including sepsis (4/69, 5.8%) and bile peritonitis (2/69, 2.9%) were also noted. Puncture-related complications such as hemobilia, biloma and bile peritonitis occurred in 8 cases (5.5%). Comparing with conventional X-ray guided drainage, ultrasound-guided percutaneous transhepatic biliary drainage is a safe procedure for

  15. Clinical Feasibility and Usefulness of CT Fluoroscopy-Guided Percutaneous Transhepatic Biliary Drainage in Emergency Patients with Acute Obstructive Cholangitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyung [Sam Anyang Hospital, Anyang (Korea, Republic of)

    2009-04-15

    To evaluate the feasibility of CT fluoroscopy (CTF)-guided percutaneous transhepatic biliary drainage (PTBD) in emergency patients with acute obstructive cholangitis. The study included 28 patients admitted to the emergency center due to obstructive jaundice and found to require urgent biliary drainage, as well as judged to have a suitable peripheral bile duct for a CTF-guided puncture (at least 4 mm in width). Prior to the CTF-guided puncture, a CT scan was performed to evaluate bile duct dilatation and the underlying causes of biliary obstruction. If the patient was judged to be a suitable candidate, a CTF-guided PTBD was performed in the same CT unit without additional fluoroscopic guidance. Technical feasibility of the procedure was investigated with the evaluation of overall success rate and causes of failure. A hepatic puncture was attempted at the left lobe in 23 patients and right lobe in five patients. The procedure was successful in 24 of 28 patients (86%) Successful biliary puncture was achieved on the first attempt in 16 patients, the second attempt in five patients, and the third attempt in three patients. The causes of failure included guide wire twisting in one patient, biliary puncture failure in two patients, and poor visualization of the guide wire in one patient. There were no significant procedure-related complication. The CTF-guided PTBD is technically feasible and highly successful in patients judged to have a suitable indication. Moreover, although the procedure is unfamiliar and inconvenient to interventionalists, it has economical advantages in that it saves time and manpower. We believe this method can be used in the emergency patients requiring urgent biliary drainage as an alternative for the fluoroscopy-guided PTBD.

  16. A New CT-Guided Modified Trocar Technique for Drainage of Difficult Locations Abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang J., E-mail: chiangjengtyng@gmail.com; Amoedo, Maurício K.; Bohrer, Yves; Bitencourt, Almir G. V.; Barbosa, Paula N. V.; Almeida, Maria Fernanda A.; Zurstrassen, Charles E. [AC Camargo Cancer Center, Department of Imaging (Brazil); Coimbra, Felipe J. F.; Costa, Wilson L. da [AC Camargo Cancer Center, Department of Abdominal Surgery (Brazil); Chojniak, Rubens [AC Camargo Cancer Center, Department of Imaging (Brazil)

    2017-05-15

    PurposeComputed tomography (CT) is commonly used to guide drainage of deep-seated abdominal fluid collections. However, in some cases, these collections seem to be inaccessible due to surrounding organs or their being in difficult locations. The aim of this study is to describe a modified Trocar technique to drain collections in difficult locations, especially those in the subphrenic space, without passing through intervening organs.Materials and MethodsThis retrospective case series study describes seven inpatients who underwent CT-guided drainage using a modified Trocar technique for abscesses that are difficult to access percutaneously. All patients provided written informed consent prior to the procedure. After placement of a 12–14F catheter inside the peritoneum, the Trocar stylet was removed so that the tip of the catheter became blunt and flexible to avoid injury to organs and structures in the catheter route, and the catheter was slowly advanced towards the collection using CT guidance and tactile sensation. After reaching the target, the stylet was reintroduced to enter the abscess wall.ResultsAll procedures were performed using an anterior abdominal wall access with adequate catheter positioning and resulted in clinical status improvement in the days after the drainage. No complications related to the procedure were identified in any of the patients.ConclusionsThe modified Trocar technique for percutaneous CT-guided drainage of abdominal abscesses may be feasible for lesions that are difficult to access with conventional methods.

  17. Efficacy of percutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts under CT guidance

    International Nuclear Information System (INIS)

    Huang Xiaoming; Huang Yongbin; Geng Lei; Zhang Haitao

    2008-01-01

    Objective: To evaluate the safety and efficacy of percutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts under CT guidance. Methods: Seventeen cases of giant hepatic and renal cyst were percutaneously implanted with 7 F pig tail drainage tube under CT guidance, together with daily injection of dehydrated ethanol or acetic acid. The drainage tube should be clamped after injection of sclerosing agent for cystic fluid 500 ml, immediate reopening of the drainage tube should be taken sright after the sclerotherapy. The withdrawal of drainage tube should be taken after resclerotherapy for all patients with < 10 ml of 24 h. drainage volume, including average of 40 d for hepatic cyst and 10 d for renal cyst. Results: 6 months after scletotherapy, all patients showed under US examination and 'healed' for all 17 cases, with successful rate up to 100%. No complication of bleeding, infection and cardioencephalovascular events occurred. Conclusion: CT guided pereutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts is simple, safe and satisfactory efficacy. (authors)

  18. Percutaneous Catheter Drainage of Periappendiceal abscess due to Appendicolith : A case report

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Heung Chueol; Han, Tae Kyun; Hur, Hun; Yum, Kung Tae; Namkung, Sook; Park, Man Soo; Hwang, Woo Chueol

    1996-01-01

    Percutaneous catheter drainage of periappendiceal abscess is an effective and safe method of treatment. It is known that CT guided approach is the first choice of method. We experienced a successful percutaneous catheter drainage under ultrasound guidance for periappendiceal abscess with appendicolith

  19. Diagnostic CT and percutaneous procedures after pancreatic transplantation

    International Nuclear Information System (INIS)

    Letourneau, J.G.; Hunter, D.W.; Thompson, W.M.; Sutherland, D.E.R.

    1987-01-01

    CT evaluation of the abdomen and pelvis is of great value after pancreatic transplantation. The expected CT appearance after pancreas transportation with both enteric and bladder drainage of exocrine function are presented, as is the appearance of infected and ischemic grafts. The CT detection and CT- and US-guided percutaneous aspiration and drainage of abdominal fluid collections are described. At the authors' institution, such aspiration and drainage procedures have obviated transplant pancreatectomy or surgical abscess drainage in 29% of patients

  20. Percutaneous transgluteal drainage of pelvic abscesses in interventional radiology: A safe alternative to surgery.

    Science.gov (United States)

    Robert, B; Chivot, C; Rebibo, L; Sabbagh, C; Regimbeau, J-M; Yzet, T

    2016-02-01

    Interventional radiology plays an important role in the management of deep pelvic abscesses. Percutaneous drainage is currently considered as the first-line alternative to surgery. A transgluteal computed tomography (CT)-guided approach allows to access to deep infected collections avoiding many anatomical obstacles (vessels, nerves, bowel, bladder). The objective of this study was to assess the safety and efficacy of a transgluteal approach by reviewing our clinical experience. We reviewed medical records of patients having undergone percutaneous CT-guided transgluteal drainage for deep pelvic abscesses. We focused on the duration of catheter drainage, the complications related to the procedures and the rate of complete resolution. Between 2005 and 2013, 39patients (27women and 12men; mean age: 52.5) underwent transgluteal approach CT-guided percutaneous drainage of pelvis abscesses in our department. The origins of abscesses were postoperative complications in 34patients (87.2%) and infectious intra-abdominal disease in 5patients (12.8%). The mean duration of drainage was 8.3days (range: 3-33). Laboratory cultures were positive in 35patients (89.7%) and Escherichia coli was present in 71.4% of the positive samples. No major complication was observed. Drainage was successful in 38patients (97.4%). A transpiriformis approach was more significantly associated with intra-procedural pain (P=0.003). Percutaneous CT-guided drainage with a transgluteal approach is a safe, well-tolerated and effective alternative to surgery for deep pelvic abscesses. This approach should be considered as the first-line intention for the treatment of deep pelvic abscesses. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. CT-guided biopsies and drainage

    International Nuclear Information System (INIS)

    Scheppers, I.; Wollschlaeger, D.

    2011-01-01

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [de

  2. Ultrasound-Guided Percutaneous Drainage of Neonatal Pyometrocolpos Under Local Anesthesia

    International Nuclear Information System (INIS)

    Algin, Oktay; Erdogan, Cuneyt; Kilic, Nizamettin

    2011-01-01

    Hydrometrocolpos is an uncommon congenital disorder with cystic dilatation of the vagina and uterus that occurs as a result of accumulated secretions from the reproductive tract due to distal genital tract obstruction. Secondary infection may also occur, resulting in pyometrocolpos, a potentially lethal disease. Immediate drainage of the cystic mass in patients determined to have pyometrocolpos is required to prevent or treat uropathy and septicemia until definitive corrective surgery can be performed. We report an unusual cause of obstructive uropathy in three infants: pyometrocolpos due to lower genital tract atresia. Ultrasound-guided percutaneous drainage of the pyometrocolpos resulted in dramatically improved clinical and laboratory findings in these patients. Ultrasound-guided percutaneous drainage under local anesthesia is a simple, minimally invasive, safe, and effective procedure that facilitates later successful corrective surgery and avoids the need for more complex drainage procedures.

  3. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  4. Computed tomography-guided percutaneous catheter drainage of primary and secondary iliopsoas abscesses

    International Nuclear Information System (INIS)

    Cantasdemir, M.; Kara, B.; Cebi, D.; Selcuk, N.D.; Numan, F.

    2003-01-01

    AIM: To report our experience with computed tomography (CT)-guided percutaneous catheter drainage (PCD) of iliopsoas abscesses. MATERIALS AND METHODS: Twenty-two iliopsoas abscesses in 21 patients (11 women, 10 men) aged between 18 and 66 years (mean 36 years) were treated with PCD. Abdominal CT demonstrated the iliopsoas abscesses, which were definitively determined by Gram staining and aspirate cultures. Twenty of the 22 iliopsoas abscesses were primary and two were secondary. All PCD procedures were performed under local anaesthesia using a single-step trocar technique (n=19) or Seldinger technique (n=3). RESULTS: PCD was an effective treatment in 21 out of the 22 iliopsoas abscesses. Recurrence was seen in three abscesses as minimal residual collections. Two of them resolved spontaneously with anti-tuberculous regimen. One required percutaneous needle aspiration. The procedure failed in a diabetic patient with a secondary abscess, who died due to sepsis. The length of time that catheters remained in place ranged from 21 to 75 days (mean 59.7 days). Complications included catheter dislocation in four abscesses, which required removal of dislocated catheters and indwelling new ones. CONCLUSION: CT-guided PCD is a safe and effective front-line treatment of iliopsoas abscesses. Surgery should be reserved for failure of PCD and presence of contraindications to PCD

  5. CT guided percutaneous needle biopsy of the chest: initial experience

    African Journals Online (AJOL)

    The objective of this article is to report our first experience of CT guided percutaneous thoracic biopsy and to demonstrate the accuracy and safety of this procedure. This was a retrospective study of 28 CT-Guided Percutaneous Needle Biopsies of the Chest performed on 24 patients between November 2014 and April 2015.

  6. Image guided percutaneous splenic interventions

    International Nuclear Information System (INIS)

    Kang, Mandeep; Kalra, Naveen; Gulati, Madhu; Lal, Anupam; Kochhar, Rohit; Rajwanshi, Arvind

    2007-01-01

    Aim: The objective of this study is to evaluate the efficacy and safety of image-guided percutaneous splenic interventions as diagnostic or therapeutic procedures. Materials and methods: We performed a retrospective review of our interventional records from July 2001 to June 2006. Ninety-five image-guided percutaneous splenic interventions were performed after informed consent in 89 patients: 64 men and 25 women who ranged in age from 5 months to 71 years (mean, 38.4 years) under ultrasound (n = 93) or CT (n = 2) guidance. The procedures performed were fine needle aspiration biopsy of focal splenic lesions (n = 78) and aspiration (n = 10) or percutaneous catheter drainage of a splenic abscess (n = 7). Results: Splenic fine needle aspiration biopsy was successful in 62 (83.78%) of 74 patients with benign lesions diagnosed in 43 (58.1%) and malignancy in 19 (25.67%) patients. The most common pathologies included tuberculosis (26 patients, 35.13%) and lymphoma (14 patients, 18.91%). Therapeutic aspiration or pigtail catheter drainage was successful in all (100%) patients. There were no major complications. Conclusions: Image-guided splenic fine needle aspiration biopsy is a safe and accurate technique that can provide a definitive diagnosis in most patients with focal lesions in the spleen. This study also suggests that image-guided percutaneous aspiration or catheter drainage of splenic abscesses is a safe and effective alternative to surgery

  7. Percutaneous catheter drainage of tuberculous psoas abscesses

    International Nuclear Information System (INIS)

    Pombo, F.; Martin-Egana, R.; Cela, A.; Diaz, J.L.; Linares-Mondejar, P.; Freire, M.

    1993-01-01

    Six patients with 7 tuberculous psoas or ilio-psoas abscesses were treated by CT-guided catheter drainage and chemotherapy. The abscesses (5 unilateral and 1 bilateral) were completely drained using a posterior or lateral approach. The abscess volume was 70 to 700 ml (mean 300 ml) and the duration of drainage 5 to 11 days (mean 7 days). Immediate local symptomatic improvement was achieved in all patients, and there were no procedural complications. CT follow-up at 3 to 9 months showed normalization in 5 patients, 2 of whom are still in medical therapy. One patient, who did not take the medication regularly, had a recurrent abscess requiring new catheter drainage after which the fluid collection disappeared. Percutaneous drainage represents an efficient and attractive alternative to surgical drainage as a supplement to medical therapy in the management of patients with large tuberculous psoas abscesses. (orig.)

  8. Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions

    International Nuclear Information System (INIS)

    Hryhorczuk, Anastasia L.; Strouse, Peter J.; Biermann, J.S.

    2011-01-01

    CT-guided percutaneous core needle biopsy has been shown in adults to be an effective diagnostic tool for a large number of musculoskeletal malignancies. To characterize our experience with CT-guided percutaneous core needle biopsy of pediatric bone lesions and determine its utility in diagnosing pediatric osseous lesions, in a population where such lesions are commonly benign. From 2000 to 2009, 61 children underwent 63 CT-guided percutaneous biopsies. Radiological, pathological and clinical records were reviewed. Fourteen biopsies (22%) were performed on malignant lesions, while 49 biopsies (78%) were performed on benign lesions. Forty-nine of the 63 biopsies (78%) were adequate; these children underwent no further tissue sampling. Fourteen of the 63 biopsies (22%) were inadequate or non-conclusive. Of these patients, 12 underwent open biopsy. Retrospective analysis of percutaneous biopsies in these patients demonstrates that 9/12 provided clinically relevant information, and 4/12 patients received final diagnoses that confirmed initial core biopsy findings. No malignancies were diagnosed as benign on percutaneous biopsy. Overall, percutaneous core needle biopsy provided accurate diagnostic information in 84% (53/63) of biopsies. Our results demonstrate that CT-guided percutaneous biopsy is safe and beneficial in children. This study supports the use of CT-guided percutaneous core needle biopsy for primary diagnosis of pediatric bone lesions. (orig.)

  9. CT guided percutaneous renal cysts puncture with ethanol therapy

    International Nuclear Information System (INIS)

    Zhang Xuezhe; Lu Yan; Wang Wu; Huang Zhengguo; Ren An

    2002-01-01

    Objective: To analyse our clinical experience with CT guided percutaneous renal cysts puncture and ethanol therapy. Methods: Five hundred and ten renal cysts in 445 patients were undergone CT guided percutaneous renal cysts puncture and ethanol therapy. Among the 445 cases, 385 cases had solitary renal cyst, 53 multiple renal cysts, and 7 polycystic kidneys. The renal cysts varied in size from 1.9 to 13.5 cm in diameter. The amount of aspirated fluid varied from 3 to 780 ml. A 18-21 gauge aspiration needles were used for all patients. A 25.0% cyst volume replacement with 99.7% ethanol was approved to be appropriate. Results: 427 renal cysts in 396 patients were followed up by computed tomographic (CT) or ultrasound for less than 3 months to more than one year duration. The curative effective rate and disappearance rate of the renal cystic cavity in solitary renal cysts were 97% and 82%, respectively. In multiple renal cysts, the corresponding values were 95% and 79%. In polycystic kidneys, the curative rate was 67%. The complications such as local abdominal pain (28 cases) and hematuria (four cases) were observed in this series. There were no fatal complications. Conclusions: CT guided percutaneous renal cyst puncture and ethanol therapy is an useful procedure for the treatment of solitary renal cysts and multiple renal cysts

  10. CT-guided percutaneous conformal cryoablation for lung carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yueyong, Xiao; Bin, Wu; Xiao, Zhang; Hongjun, Li; Da, Yu; Jie, Li; Jun, Li [Department of Radiology, PLA General Hospital, Beijing (China)

    2010-02-15

    month follow-up. Seven patients were followed up 2 years later, 5 of them have no recurrence or metastasis, one had mediastinal lymphopathy and one had bone metastasis 1 year later. For the 22 cases with maximum diameters between 3.0 CM and 5.0 cm, CT scan during procedure showed the frozen areas covered the lesions, lobulation and spiculation disappeared and the tumor size slightly enlarged. The lesions volume reduced during 1 st and 3 rd month follow-up. Nine cases were followed up for 2 years, 4 had no recurrence, 3 were stable and 2 had remote metastasis. For 26 cases with the maximum diameters larger than 5.0 cm, CT scan during the procedure showed the frozen areas covered 70%-90% of the tumor, there was no frozen damage to the surrounding lung tissue. Twenty-six patients had postoperative radiotherapy and chemotherapy. Follow-up in the 6 th month showed that 9 lesions decreased, 11 were stable and 6 progressed with remote metastasis. Complications included hemoptysis (3), bloody sputum (26), pneumothorax (19). Five pneumothorax were treated by close drainage and recovered 5 days. Conclusion: CT-guided percutaneous conformal cryoablation is an effective and minimal invasive procedure for the lung carcinoma treatment. (authors)

  11. CT-guided percutaneous conformal cryoablation for lung carcinoma

    International Nuclear Information System (INIS)

    Xiao Yueyong; Wu Bin; Zhang Xiao; Li Hongjun; Yu Da; Li Jie; Li Jun

    2010-01-01

    month follow-up. Seven patients were followed up 2 years later, 5 of them have no recurrence or metastasis, one had mediastinal lymphopathy and one had bone metastasis 1 year later. For the 22 cases with maximum diameters between 3.0 CM and 5.0 cm, CT scan during procedure showed the frozen areas covered the lesions, lobulation and spiculation disappeared and the tumor size slightly enlarged. The lesions volume reduced during 1 st and 3 rd month follow-up. Nine cases were followed up for 2 years, 4 had no recurrence, 3 were stable and 2 had remote metastasis. For 26 cases with the maximum diameters larger than 5.0 cm, CT scan during the procedure showed the frozen areas covered 70%-90% of the tumor, there was no frozen damage to the surrounding lung tissue. Twenty-six patients had postoperative radiotherapy and chemotherapy. Follow-up in the 6 th month showed that 9 lesions decreased, 11 were stable and 6 progressed with remote metastasis. Complications included hemoptysis (3), bloody sputum (26), pneumothorax (19). Five pneumothorax were treated by close drainage and recovered 5 days. Conclusion: CT-guided percutaneous conformal cryoablation is an effective and minimal invasive procedure for the lung carcinoma treatment. (authors)

  12. CT Fluoroscopy-Guided Transsacral Intervertebral Drainage for Pyogenic Spondylodiscitis at the Lumbosacral Junction

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Tomohiro, E-mail: t-matsu@tokai-u.jp; Mine, Takahiko, E-mail: mine@tsc.u-tokai.ac.jp; Hayashi, Toshihiko, E-mail: t.hayashi@tokai.ac.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan); Kamono, Masahiro, E-mail: kamono@tsc.u-tokai.ac.jp; Taoda, Akiko, E-mail: acco@is.icc.u-tokai.ac.jp; Higaki, Megumu, E-mail: higaki@hachioji-hosp.tokai.ac.jp [Tokai University School of Medicine, Department of General Internal Medicine, Tokai University Hachioji Hospital (Japan); Hasebe, Terumitsu, E-mail: hasebe@tokai-u.jp [Tokai University School of Medicine, Department of Radiology, Tokai University Hachioji Hospital (Japan)

    2017-01-15

    PurposeTo retrospectively describe the feasibility and efficacy of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction with a combination of two interventional radiological techniques—CT-guided bone biopsy and abscess drainage.Materials and methodsThree patients with pyogenic spondylodiscitis at the lumbosacral junction were enrolled in this study between July 2013 and December 2015. The procedure of CT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction was as follows: the sacrum at S1 pedicle was penetrated with an 11-gauge (G) bone biopsy needle to create a path for an 8-French (F) pigtail drainage catheter. The bone biopsy needle was withdrawn, and an 18-G needle was inserted into the intervertebral space of the lumbosacral junction. Then, a 0.038-inch guidewire was inserted into the intervertebral space. Finally, the 8-F pigtail drainage catheter was inserted over the guidewire until its tip reached the intervertebral space. All patients received six-week antibiotics treatment.ResultsSuccessful placement of the drainage catheter was achieved for each patient without procedural complications. The duration of drainage was 17–33 days. For two patients, specific organisms were isolated; thus, definitive medical therapy was possible. All patients responded well to the treatment.ConclusionsCT fluoroscopy-guided transsacral intervertebral drainage for pyogenic spondylodiscitis at the lumbosacral junction is feasible and can be effective with a combination of two interventional techniques—CT fluoroscopy-guided bone biopsy and abscess drainage.

  13. The prevention and treatment of biliary complications occurred after CT-guided percutaneous radiofrequency ablation for hepatic neoplasms

    International Nuclear Information System (INIS)

    Li Jianjun; Zheng Jiasheng; Cui Xiongwei; Cui Shichang; Sun Bin

    2011-01-01

    Objective: To discuss the prevention and treatment of biliary complications occurred after CT-guided percutaneous radiofrequency ablation (RFA) for hepatic neoplasms. Methods: A total of 1136 patients, including 920 males and 216 females, with hepatic neoplasms were enrolled in this study. The hepatic tumors consisted of primary hepatocellular carcinoma (n=1037), hepatic metastasis (n=83) and hepatic cavernous hemangioma (n=16). The diameters of the tumors ranged from 0.5 to 16 cm. A total of 1944 RFA procedures were carried out in all patients. Results: Thirty-five patients developed biliary complication (35/1944, 1.80%). Twelve patients developed asymptomatic bile duct dilatation and no special treatment was given. Obstructive jaundice occurred in two patients and percutaneous transhepatic cholangiocholecystic drainage (PTCD) together with subsequent inner stent implantation had to be carried out. Eighteen patients developed biloma, and liver abscess formation secondary to biloma infection occurred in seven of them. Percutaneous transhepatic biloma drainage (PTBD) was adopted in all these patients. One patient suffered from obstructive jaundice complicated by biloma, and both PTCD and PTBD combined with inner stent implantation were simultaneously performed. One patient had the biloma secondary to obstructive jaundice, and PTCD followed by PTBD was conducted in turn. One patient developed obstructive jaundice secondary to biloma, and PTBD followed by PTCD was employed in turn. Conclusion: Obstructive jaundice and biloma are severe biliary complications occurred after CT-guided percutaneous radiofrequency ablation for hepatic tumors, and PTCD and/or PTBD should be carried out without delay to treat these complications. The clinical symptoms can be relieved, or even completely disappear, after treatment. (authors)

  14. Endoscopic ultrasound-guided transmural drainage of postoperative pancreatic collections.

    Science.gov (United States)

    Tilara, Amy; Gerdes, Hans; Allen, Peter; Jarnagin, William; Kingham, Peter; Fong, Yuman; DeMatteo, Ronald; D'Angelica, Michael; Schattner, Mark

    2014-01-01

    Pancreatic leak is a major cause of morbidity after pancreatectomy. Traditionally, peripancreatic fluid collections have been managed by percutaneous or operative drainage. Data for endoscopic ultrasound (EUS)-guided drainage of postoperative fluid collections are limited. Here we report on the safety, efficacy, and timing of EUS-guided drainage of postoperative peripancreatic collections. This is a retrospective review of 31 patients who underwent EUS-guided drainage of fluid collections after pancreatic resection. Technical success was defined as successful transgastric deployment of at least one double pigtail plastic stent. Clinical success was defined as resolution of the fluid collection on follow-up CT scan and resolution of symptoms. Early drainage was defined as initial transmural stent placement within 30 days after surgery. Endoscopic ultrasound-guided drainage was performed effectively with a technical success rate of 100%. Clinical success was achieved in 29 of 31 patients (93%). Nineteen of the 29 patients (65%) had complete resolution of their symptoms and collection with the first endoscopic procedure. Repeat drainage procedures, including some with necrosectomy, were required in the remaining 10 patients, with eventual resolution of collection and symptoms. Two patients who did not achieve durable clinical success required percutaneous drainage by interventional radiology. Seventeen (55%) of 31 patients had successful early drainage completed within 30 days of their operation. Endoscopic ultrasound-guided drainage of fluid collections after pancreatic resection is safe and effective. Early drainage (collections was not associated with increased complications in this series. Copyright © 2014 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Study of CT-guided percutaneous biopsy for the spine lesions

    International Nuclear Information System (INIS)

    Zhang Ji; Wu Chungen; Cheng Yongde; Zhu Xuee; Gu Yifeng; Zhang Huijian

    2008-01-01

    Objective: To determine the successful rate, diagnostic accuracy and clinical usefulness of CT-guided percutaneous biopsy for the spine lesions. Methods: Eight-five patients (61 outpatients, 24 ward patients)underwent CT-guided percutaneous biopsy for the spine lesion. The imaging appearance of spinal lesions were lytic in 57 cases, osteosclerotic in 19 cases, and mixed in 9 cases. Biopsy specimens were sent for cytologic and histologic analysis in order to correct diagnosis. Bacterial studies were performed when ever infection was suspected. Results: The localization of puncture biopsy needle inside the spinal lesions, was conformed by computed tomography including 3 cervical, 26 thoracic, 37 lumbar, and 19 sacral lesions. Biopsy specimens included bone (29 cases), soft tissue (5 cases), mixed tissue (47 cases )and no specimen be obtained(4 cases). An adequate specimen for pathologic examination was obtained in 81 biopsies (95%). The pathologic examinations revealed 44 metastases, 17 primary bone neoplasms, 18 infections (included tuberculosis)and 2 normal tissues of vertebral body. The diagnostic accuracy reached 97.5% (79 of 81 patients). Conclusions: CT-guided percutaneous biopsy is an important tool in the evaluation of spinal lesions, providing accurate localization, less trauma and reliable pathologic diagnosis and worthwhile to be the routine before vertebroplasy. (authors)

  16. Analysis of diagnositc accuracy with CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Haiyan; Zhuang Yiping; Zhang Jin; Feng Yong; Zhang Xiao; Xu Lin

    2007-01-01

    Objective: To evaluate the factors which may affect the diagnostic accmracy of CT-guided percutaneous transthoracic lung biopsy for pulmonary lesions. Methods: CT-guided percutaneous transthoracic lung biopsy was performed in 264 patients, all of which were proved by surgical pathology or clinical follow-up. A logistic regression analysis was used to investigate the relationship between the location and the size of the lesions and insertion depth of biopsy needles and the diagnostic accuracy of CT-guided percutaneous transthomcic lung biopsy. The complication rate including pneumatothorax and bleeding rate were record. Results: The diagnostic accuracy was 87.5%. Both the pneumothorax and the bleeding of lesion were 1.9%. The size of lesion was suggested by Logistic regression analysis had a significant influence on the diagnostic accuracy (Wald=12.891, P=0.00034, OR=0.96). Conclusion: CT-guided pereumneous transthoracic lung biopsy has a high diagnostic accuracy for pulmonary lesions. The size of the lesions had significant effect on the diagnostic accuracy. (authors)

  17. Radiologically-guided catheter drainage of intrathoracic abscesses and empyemas

    International Nuclear Information System (INIS)

    Berger, H.; Steiner, W.; Bergman, C.; Anthuber, M.; Dienemann, H.

    1993-01-01

    Radiologically guided percutaneous catheter drainage was used in 38 patients to treat pleural empyemas (35 patients) and pulmonary abscesses (3 patients). Drainage was successful in 85.7% of empyemas including 11 cases with fistulous communications. Three percutaneously drained pulmonary abscesses required subsequent lobectomy. One patient died during the drainage procedure due to sepsis. No major complications related to the drainage procedure were observed. Guided percutaneous drainage proved to be a safe and successful alternative to closed drainage of pleural fluid collections. (orig.)

  18. Percutaneous CT-guided cryoablation for the treatment of refractory pudendal neuralgia

    Energy Technology Data Exchange (ETDEWEB)

    Prologo, J.D.; Williams, Roger [Emory University Hospital, Department of Radiology and Imaging Sciences Division of Interventional Radiology and Image-Guided Medicine, Atlanta, GA (United States); Lin, Roger C. [University Hospitals Case Medical Center, Department of Radiology, Cleveland, OH (United States); Corn, David [Case Western Reserve University, Department of Biomedical Engineering, Cleveland, OH (United States)

    2015-05-01

    To evaluate the safety and efficacy of percutaneous CT-guided cryoablation of the pudendal nerve for the treatment of refractory pudendal neuralgia. Eleven patients were selected to undergo percutaneous CT-guided cryoablation of the pudendal nerve based on established diagnostic criteria. Brief Pain Inventory questionnaires were administered prior to the procedure, during the immediate 24 h post procedure, and 45 days and 6 months following the procedure. Prior to treatment, the average level of pain on a scale from 0 (no pain) to 10 (worst pain imaginable) was 7.6, with pain described as ''burning'' (80%), ''pulling'' (37.5%), ''crushing'' (50%), ''pressure'' (84.5%), ''throbbing'' (50%), ''knife-life'' (52%), and ''other'' (60%). At 24 h, 45 days, and 6 months post-treatment, pain intensity dropped to 2.6, 3.5, and 3.1, respectively (p < 0.005). There were no procedure-related complications. CT-guided percutaneous cryoablation may represent a safe and efficacious option for selected patients with refractory pudendal neuralgia. (orig.)

  19. Bilateral CT-guided percutaneous cordotomy for cancer pain relief

    Energy Technology Data Exchange (ETDEWEB)

    Yegul, I. E-mail: iyegul@med.ege.edu.tr; Erhan, E. E-mail: elvanerhan@yahoo.com

    2003-11-01

    AIM: CT-guided percutaneous cordotomy is a useful procedure for treating unilateral cancer pain, however, bilateral cordotomy can be required on some occasions. We evaluated the effectiveness and complications of bilateral cordotomy. MATERIALS AND METHODS: Two hundred and thirty-four patients who suffered from unilateral cancer pain underwent CT-guided percutaneous cordotomy. The procedure was repeated in 22 patients, and nine patients had bilateral cordotomy. Effectiveness and complications were recorded after each procedure. RESULTS: Of nine patents (three women and six men) having bilateral percutaneous cordotomy in our study, four patients had mirror pain after the first procedure. In the remaining five patients the contralateral pain was due to new pain sites. The pain scores before and after the first procedure were 9.3 (range 7-10) and 1.2 (range 0-3), respectively. After the first procedure complete or satisfactory pain relief was achieved in all patients. The duration between the two procedures ranged from 7-243 days (mean 59.8 days). The pain scores before and after the second procedure were 8.4 (range 5-10) and 1.6 (range 0-4), respectively. After the second procedure complete or satisfactory pain relief was reported in all patients. There were no complications in four patients. One patient developed transient motor deficit after the first procedure. Other complications (nausea/vomiting, headache, ipsilateral neck pain, postcordotomy dysesthesia) were mild and transient. CONCLUSION: CT-guided percutaneous cordotomy is a useful procedure for the treatment of severe unilateral cancer pain syndromes. The procedure can be repeated on the other side at least 1 week later. These results show that the success on the second side appears to be similar to the first side with low complication rate for both procedures.

  20. Bilateral CT-guided percutaneous cordotomy for cancer pain relief

    International Nuclear Information System (INIS)

    Yegul, I.; Erhan, E.

    2003-01-01

    AIM: CT-guided percutaneous cordotomy is a useful procedure for treating unilateral cancer pain, however, bilateral cordotomy can be required on some occasions. We evaluated the effectiveness and complications of bilateral cordotomy. MATERIALS AND METHODS: Two hundred and thirty-four patients who suffered from unilateral cancer pain underwent CT-guided percutaneous cordotomy. The procedure was repeated in 22 patients, and nine patients had bilateral cordotomy. Effectiveness and complications were recorded after each procedure. RESULTS: Of nine patents (three women and six men) having bilateral percutaneous cordotomy in our study, four patients had mirror pain after the first procedure. In the remaining five patients the contralateral pain was due to new pain sites. The pain scores before and after the first procedure were 9.3 (range 7-10) and 1.2 (range 0-3), respectively. After the first procedure complete or satisfactory pain relief was achieved in all patients. The duration between the two procedures ranged from 7-243 days (mean 59.8 days). The pain scores before and after the second procedure were 8.4 (range 5-10) and 1.6 (range 0-4), respectively. After the second procedure complete or satisfactory pain relief was reported in all patients. There were no complications in four patients. One patient developed transient motor deficit after the first procedure. Other complications (nausea/vomiting, headache, ipsilateral neck pain, postcordotomy dysesthesia) were mild and transient. CONCLUSION: CT-guided percutaneous cordotomy is a useful procedure for the treatment of severe unilateral cancer pain syndromes. The procedure can be repeated on the other side at least 1 week later. These results show that the success on the second side appears to be similar to the first side with low complication rate for both procedures

  1. CT-guided percutaneous gastrostomy: success rate, early and late complications; CT-gesteuerte perkutane Gastrostomie: Technischer Erfolg, Frueh- und Spaetkomplikationen

    Energy Technology Data Exchange (ETDEWEB)

    Gottschalk, A.; Voelk, M. [Radiologie, Bundeswehrkrankenhaus Ulm (Germany); Strotzer, M. [Radiologie, Klinikum Hohe Warte (Germany); Feuerbach, S.; Rogler, G. [Radiologie, Klinikum der Universitaet Regensburg (Germany); Seitz, J. [Radiologie, MVZ Dr. Neumaier und Kollegen (Germany)

    2007-04-15

    Purpose: Percutaneous endoscopic gastrostomy (PEG) and percutaneous radiologic gastrostomy (PRG) are the standard methods of ensuring long-term enteral food intake in patients with dysphagia caused by neoplasia or neurological disorders. High-grade obstructions of the upper digestive tract or inadequate transillumination can prevent PEG. CT-guided percutaneous gastrostomy (PG) represents a special technique for enabling gastrostomy in patients for whom the endoscopic method is impossible. The aim of this study was to evaluate the results and complications of CT-guided percutaneous gastrostomy. Materials and Methods: CT-guided PG was performed in 83 patients, mostly with malignancy of the upper respiratory or digestive tract. Medical records for these patients were reviewed, and the results and complications of the CT-guided PG were analyzed retrospectively. Complications were grouped into four categories: Major and minor complications as well as early and late complications. Results: In 95.2 % of all cases (79/83), CT-guided PG was successful in the first attempt. Within the first 3 days, 5 major complications including 4 tube dislocations and one case of peritonitis were found in 4/79 patients (5.1 %). One of these patients experienced two early major complications. Early minor complications, mainly local skin irritations and temporary stomachache, were observed in 31 patients (39.2 %). Three days after CT-guided PG, 4 cases of major complications were documented, yielding a total rate of major complications was 8.7 % (7/79). Hemorrhage requiring blood transfusion or perforation after gastrostomy was not observed. 29.1 % of the patients (23/79) experienced late minor complications. (orig.)

  2. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    Energy Technology Data Exchange (ETDEWEB)

    Gevargez, A.; Schirp, S.; Braun, M. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); Groenemeyer, D. [Department of Radiology and Microtherapy, University of Witten/Herdecke, Bochum (Germany); EFMT Development and Research Center for Microtherapy, Bochum (Germany)

    2002-06-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  3. CT-guided percutaneous radiofrequency denervation of the sacroiliac joint

    International Nuclear Information System (INIS)

    Gevargez, A.; Schirp, S.; Braun, M.; Groenemeyer, D.

    2002-01-01

    Defining the origin of low back pain is a challenging task. Among a variety of factors the sacroiliac joint (SIJ) is a possible pain generator, although precise diagnosis is difficult. Joint blocks may reduce pain, but are, in cases, of only temporary effect. This study was conducted to evaluate CT-guided percutaneous radiofrequency denervation of the sacroiliac joint in patients with low back pain. The procedure was performed on 38 patients who only temporarily responded to CT-guided SIJ blocks. The denervation was carried out in the posterior interosseous sacroiliac ligaments and on the dorsal rami of the fifth spinal nerve. All interventions were carried out under CT guidance as out-patient therapies. Three months after the therapy, 13 patients (34.2%) were completely free of pain. Twelve patients (31.6%) reported on a substantial pain reduction, 7 patients (18.4%) had obtained a slight and 3 patients (7.9%) no pain reduction. The data of 3 patients (7.9%) was missing. There were no intra- or postoperative complications. Computed tomography-guided percutaneous radiofrequency denervation of the sacroiliac joint appears safe and effective. The procedure may be a useful therapeutic modality, especially in patients with chronic low back pain, who only temporarily respond to therapeutic blocks. (orig.)

  4. Percutaneous drainage of diverticular abscess: Adjunct to resection

    International Nuclear Information System (INIS)

    Mueller, P.R.; Saini, S.; Butch, R.J.; Simeone, J.F.; Rodkey, G.V.; Bousquet, J.C.; Ottinger, L.W.; Wittenberg, J.; Ferrucci, J.T. Jr.

    1986-01-01

    Traditional surgical management of acute diverticulitis with abscess may require a one-, two-, or three-stage procedure. Because of recent interest in CT diagnosis of diverticulitis, and novel access routes for interventional drainage of deep pelvic abscesses, the authors investigated the potential for converting complex two- and three-stage surgical procedures to simpler, safer one-stage colon resections by percutaneous drainage of the associated abscess. Of 23 patients with acute perforated diverticulitis who were referred for catheter drainage under radiologic guidance, successful catheter drainage and subsequent single-stage colon resection were carried out in 15. In three patients catheter drainage was unsuccessful and a multistage procedure was required. In three patients only percutaneous drainage was performed and operative intervention was omitted entirely

  5. CT-guided biopsies and drainage; CT-gesteuerte Punktionen und Drainagen

    Energy Technology Data Exchange (ETDEWEB)

    Scheppers, I.; Wollschlaeger, D. [Staedtisches Klinikum Karlsruhe gGmbH, Zentralinstitut fuer Bildgebende Diagnostik, Karlsruhe (Germany)

    2011-11-15

    Following the implementation of computed tomography (CT) or ultrasound-guided biopsy of solid tumors and the puncture and drainage of liquid processes, the number of surgical open biopsies and curative operations for abscess drainage has declined. Such CT-guided interventions are performed in nearly every organ. Instead of aspiration biopsies, more and more core biopsies are being performed to allow histopathological evaluation and thus allowing targeted therapy. This article is intended to give a general overview of techniques, materials, indications and contraindications. Ultrasound-guided biopsies as well as large bore vacuum biopsies of the breast are not included in this review. (orig.) [German] Infolge der Durchfuehrung von bildgesteuerten Biopsien solider Raumforderungen und Punktionen mit Drainageeinlage bei liquiden Prozessen ist die Zahl chirurgischer Exzisionsbiopsien und Abszesssanierungen zurueckgegangen. Diese Eingriffe werden in nahezu allen Organgebieten durchgefuehrt. Neben den Aspirationsbiopsien werden haeufig Schneid- oder Stanzbiopsien durchgefuehrt. Nach histologischer und immunhistologischer Untersuchung der hierbei gewonnenen Proben in der Pathologie kann fruehzeitig die nachfolgende Therapie geplant werden. Der vorliegende Beitrag soll einen allgemeinen Ueberblick ueber Methoden, Materialien, Indikationen und Kontraindikationen geben. Die ultraschallgesteuerten Biopsien sowie die Vakuumsaugbiopsien im Rahmen des Mammographiescreenings werden bewusst nicht besprochen. (orig.)

  6. Ultrasound-guided percutaneous drainage of meniscal cysts: preliminary clinical experience

    International Nuclear Information System (INIS)

    MacMahon, P.J.; Brennan, D.D.; Duke, D.; Forde, S.; Eustace, S.J.

    2007-01-01

    Aim: To evaluate the efficacy of ultrasound-guided percutaneous drainage of symptomatic meniscal cysts. Materials and methods: Patients with lateral knee joint tenderness and swelling and confirmed meniscal cyst on magnetic resonance imaging (MRI) were consecutively enrolled for ultrasound-guided percutaneous cyst aspiration. Cysts were injected with local anaesthetic and steroid before completion of procedure. All 18 patients (all male, average age 33 years) were subsequently followed up (average time 10 months) and meniscal cyst symptoms assessed by questionnaire. Fischer's exact test used to analyse the data. Results: In every case the procedure was well tolerated, and each patient indicated that they would be willing to have a repeat procedure in the future. Ten patients reported complete resolution of symptoms secondary to therapeutic cyst aspiration and had resumed participation in high-performance sport. Two patients reported a satisfactory sustained response, reporting only occasional 'twinges of pain'. In the remaining six patients, symptoms returned after an initial pain-free period. The pain-free period ranged from 1-8 weeks. In this study, patient outcome did not significantly correlate with any meniscal cyst characteristic. Conclusion: Ultrasound-guided percutaneous aspiration of meniscal cysts is a well-tolerated, simple, and safe procedure. In this small patient series, it was associated with positive early results with favourable outcomes in the mid to long-term. It should be considered in patients unsuitable for surgical debridement or as an interim therapy if surgery is delayed or postponed

  7. Percutaneous drainage of 100 subphrenic abscesses

    International Nuclear Information System (INIS)

    Casola, G.; Sonnenberg, E. van; D'Agostino, H.; Kothari, R.; May, S.; Taggart, S.

    1990-01-01

    PURPOSE: Percutaneous drainage of subphrenic abscesses is technically more difficult because lung and pleura may be transgressed during catheter insertion. The purpose of this paper is to determine the incidence of thoracic complications secondary to subphrenic abscess drainage and to determine factors that may alter this. The authors' series consists of 100 subphrenic abscesses that were drained percutaneously. Patients range in age from 14 to 75 years. Abscesses were secondary to surgery (splenectomy, pancreatectomy, partial hepatectomy, gastrectomy), pancreatitis, and trauma. Catheters ranged in size from 8 to 14 F and were inserted via trocar or Seldinger technique. Thoracic complications of pneumothorax or empyema were determined from follow-up chest radiographs or CT scans

  8. Percutaneous Transhepatic Drainage of Inaccessible Abdominal Abscesses Following Abdominal Surgery Under Real-Time CT-Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Nakatsuka, Atsuhiro; Kashima, Masataka; Uraki, Junji; Yamanaka, Takashi; Takeda, Kan

    2010-01-01

    This study evaluated the safety, feasibility, and clinical utility of transhepatic drainage of inaccessible abdominal abscesses retrospectively under real-time computed tomographic (CT) guidance. For abdominal abscesses, 12 consecutive patients received percutaneous transhepatic drainage. Abscesses were considered inaccessible using the usual access route because they were surrounded by the liver and other organs. The maximum diameters of abscesses were 4.6-9.5 cm (mean, 6.7 ± 1.4 cm). An 8-Fr catheter was advanced into the abscess cavity through the liver parenchyma using real-time CT fluoroscopic guidance. Safety, feasibility, procedure time, and clinical utility were evaluated. Drainage catheters were placed with no complications in abscess cavities through the liver parenchyma in all patients. The mean procedure time was 18.8 ± 9.2 min (range, 12-41 min). All abscesses were drained. They shrank immediately after catheter placement. In conclusions, this transhepatic approach under real-time CT fluoroscopic guidance is a safe, feasible, and useful technique for use of drainage of inaccessible abdominal abscesses.

  9. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Akio, E-mail: a.akahane@gmail.com; Kato, Kenichi, E-mail: kkato@iwate-med.ac.jp; Suzuki, Michiko, E-mail: mamimichiko@me.com [Iwate Medical University School of Medicine, Department of Radiology (Japan); Sone, Miyuki, E-mail: msone@me.com [National Cancer Center Hospital, Department of Diagnostic Radiology (Japan); Tanaka, Ryoichi, E-mail: rtanaka@iwate-med.ac.jp; Nakasato, Tatsuhiko, E-mail: nakasato@iwate-med.ac.jp; Ehara, Shigeru, E-mail: ehara@iwate-med.ac.jp [Iwate Medical University School of Medicine, Department of Radiology (Japan)

    2016-02-15

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC.

  10. CT-Guided Percutaneous Radiologic Gastrostomy for Patients with Head and Neck Cancer: A Retrospective Evaluation in 177 Patients

    International Nuclear Information System (INIS)

    Tamura, Akio; Kato, Kenichi; Suzuki, Michiko; Sone, Miyuki; Tanaka, Ryoichi; Nakasato, Tatsuhiko; Ehara, Shigeru

    2016-01-01

    PurposeThe purpose of this study was to assess the technical success rate and adverse events (AEs) associated with computed tomography (CT)-guided percutaneous gastrostomy for patients with head and neck cancer (HNC).Materials and MethodsThis retrospective study included patients with HNC who had undergone CT-guided percutaneous gastrostomy between February 2007 and December 2013. Information regarding the patients’ backgrounds, CT-guided percutaneous gastrostomy techniques, technical success rate, and AEs were obtained from the medical records. In all patients, the stomach was punctured under CT fluoroscopy with a Funada gastropexy device.ResultsDuring the study period, 177 patients underwent CT-guided percutaneous gastrostomy. The most common tumor location was the oral cavity, followed by the pharynx and maxilla. The indication for CT-guided percutaneous gastrostomy were tumor obstruction in 78 patients, postoperative dysphagia in 55 patients, radiation edema in 43 patients, and cerebral infarction in 1 patient. The technical success rate was 97.7 %. The overall mean procedure time was 25.3 min. Major AEs occurred in seven patients (4.0 %), including bleeding (n = 4), colonic injury (n = 1), gastric tear (n = 1), and aspiration pneumonia (n = 1). Minor AEs occurred in 15 patients (8.5 %), which included peristomal leakage (n = 6), irritation (n = 4), inadvertent removal (n = 2), peristomal hemorrhage (n = 1), peristomal infection (n = 1), and wound granulation (n = 1). The mean follow-up period was 111 days (range 1–1106 days).ConclusionOur study suggests that CT-guided gastrostomy may be suitable in patients with HNC

  11. The comparative study of CT guided and ultrasound guided percutaneous ethanol injection in the treatment of intra-abdominal cyst

    International Nuclear Information System (INIS)

    Li Heping; Yang Jianyong; Chen Wei; Zhuang Wenquan; Huang Yulian; Chen Jianye

    2005-01-01

    Objective: An comparative study of the interventional approach of CT guided and ultiasound guided percutaneous ethanol injection(PEI) in the treatment of intra-abdominal cyst. Methods: CT guided PEI was performed in the treatment of intra-abdominal cyst in 38 patients while ultrasound guided PEI was performed in 45 cases. Results: The puncture procedure of CT guided PEI was totally performed 83 times in treating 56 intra-abdominal cysts in 38 patients and CT guided PEI was unsuccessful in 6 patients. The puncture procedure of ultrasound guided PEI were performed 87 times in treating 71 intra-abdominal cysts in 55 patients and ultrasound guided PEI only failed only in 1 patient. Conclusion: Ultrasound guided PEI is superior to CT guided PEI in the treatment of intra-abdominal cyst. (authors)

  12. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  13. Factors influencing diagnostic yield of CT-guided percutaneous core needle biopsy for bone lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2014-01-01

    Aim: To evaluate the factors influencing diagnostic yield of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for bone lesions. Materials and methods: Between September 2005 and July 2011, 162 consecutive CT-guided CNB procedures were performed in 155 patients. The variables analysed were age, sex, lesion location, lesion type, lesion size, specimen size, biopsy needle gauge, and individual radiologist. The factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were determined by multivariate analysis of variables. Results: The diagnostic yield was 81.5%. Diagnostic yield was 89.9% for lytic bone lesions and 48.5% for sclerotic bone lesions (p < 0.001), and 89.2% for lesions ≥3 cm and 73.4% for lesions <3 cm (p = 0.010). The significant factors influencing diagnostic yield of CT-guided percutaneous CNB for bone lesions were lesion type [p < 0.001; odds ratio (OR) for a lytic lesion was approximately 12 times higher than that for a sclerotic lesion; 95% confidence interval (CI): 4.22–34.01], and lesion size (p = 0.012; OR for a lesion size ≥3 cm was about five-times higher than that for a lesion size <3 cm; 95% CI: 1.42–16.71). Conclusion: Lesion type and lesion size are determining factors in diagnostic yield. The higher diagnostic yield is correlated with lytic lesion and lesion size ≥3 cm

  14. Usefulness of CT fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy

    International Nuclear Information System (INIS)

    O, Dong Hyun; Cho, Young Jun; Park, Yong Sung; Hwang, Cheol Mok; Kim, Keum Won; Kim, Ji Hyung

    2006-01-01

    When pneumothorax occurs during a percutaneous needle biopsy, the radiologist usually stops the biopsy. We evaluated the usefulness of computed tomographic (CT) fluoroscopy-guided percutaneous needle biopsy in the presence of pneumothorax during biopsy. We performed 288 CT fluoroscopy guided percutaneous needle biopsies to diagnose the pulmonary nodules. Twenty two of these patients had pneumothorax that occurred during the biopsy without obtaining an adequate specimen. After pneumothorax occurred, we performed immediate CT fluoroscopy guided percutaneous needle biopsies using an 18-gauge cutting needle. We evaluated the success rate of the biopsies and also whether or not the pneumothorax progressed. We classified these patients into two groups according to whether the pneumothorax progressed (Group 2) or not (Group 1) by measuring the longest distance between the parietal pleura and the visceral pleura both in the early and late pneumothorax. Additionally, we analyzed the relationship between the progression of pneumothorax after biopsy and 1) the depth of the pulmonary nodule; 2) the number of biopsies; 3) the presence or absence of emphysema at the biopsy site; and 4) the size of the pulmonary nodule. Biopsy was successful in 19 of 22 nodules (86.3%). Of the 19 nodules, 12 (63.2%) were malignant and 7 (36.8%) were benign. Twelve patients (54.5%) were classified as group 1 and 10 patients (45.4%) as group 2. The distance between the lung lesion and pleura showed a statistically significant difference between these two groups: ≤ 1 cm in distance for group 1 (81.8%) and group 2 (18.2%), and > 1 cm in distance for group 1 (30%) and group 2 (70%), ρ 0.05). When early pneumothorax occurs during a biopsy, CT fluoroscopy guided percutaneous needle biopsy is an effective and safe procedure. Aggravation of pneumothorax after biopsy is affected by the depth of the pulmonary nodule

  15. Nonsurgical drainage of splenic abscess

    International Nuclear Information System (INIS)

    Berkman, W.A.; Harris, S.A. Jr.; Bernardino, M.E.

    1983-01-01

    The mortality associated with intraabdominal abscess remains high despite modern surgical methods and antibiotics. Draingae of abscesses of the abdomen, retroperitoneum, pelvis, pancreatic pseudocyst, mediastinum, and lung may be treated effectively by percutaneous catheter placement. In several reports of percutaneous abdominal abscess drainage, only three cases of splenic abscess drainage have been reported. The authors have recently drained two splenic abscesses with the aid of computed tomography (CT) and emphasize several advantages of the percutaneous guided approach

  16. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  17. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  18. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  19. Percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Park, Jae Hyung; Hong, Seong Mo; Han, Man Chung

    1982-01-01

    Percutaneous transhepatic biliary drainage was successfully made 20 times on 17 patients of obstructive jaundice for recent 1 year since June 1981 at Department of Radiology in Seoul National University Hospital. The causes of obstructive jaundice was CBD Ca in 13 cases, metastasis in 2 cases, pancreatic cancer in 1 case and CBD stone in 1 case. Percutaneous transhepatic biliary drainage is a relatively ease, safe and effective method which can be done after PTC by radiologist. It is expected that percutaneous transhepatic biliary drainage should be done as an essential procedure for transient permanent palliation of obstructive jaundice

  20. Diagnostic Yield of CT-Guided Percutaneous Transthoracic Needle Biopsy for Diagnosis of Anterior Mediastinal Masses.

    Science.gov (United States)

    Petranovic, Milena; Gilman, Matthew D; Muniappan, Ashok; Hasserjian, Robert P; Digumarthy, Subba R; Muse, Victorine V; Sharma, Amita; Shepard, Jo-Anne O; Wu, Carol C

    2015-10-01

    The purpose of this study was to evaluate the diagnostic yield and accuracy of CT-guided percutaneous biopsy of anterior mediastinal masses and assess prebiopsy characteristics that may help to select patients with the highest diagnostic yield. Retrospective review of all CT-guided percutaneous biopsies of the anterior mediastinum conducted at our institution from January 2003 through December 2012 was performed to collect data regarding patient demographics, imaging characteristics of biopsied masses, presence of complications, and subsequent surgical intervention or medical treatment (or both). Cytology, core biopsy pathology, and surgical pathology results were recorded. A per-patient analysis was performed using two-tailed t test, Fisher's exact test, and Pearson chi-square test. The study cohort included 52 patients (32 men, 20 women; mean age, 49 years) with mean diameter of mediastinal mass of 6.9 cm. Diagnostic yield of CT-guided percutaneous biopsy was 77% (40/52), highest for thymic neoplasms (100% [11/11]). Non-diagnostic results were seen in 12 of 52 patients (23%), primarily in patients with lymphoma (75% [9/12]). Fine-needle aspiration yielded the correct diagnosis in 31 of 52 patients (60%), and core biopsy had a diagnostic rate of 77% (36/47). None of the core biopsies were discordant with surgical pathology. There was no statistically significant difference between the diagnostic and the nondiagnostic groups in patient age, lesion size, and presence of necrosis. The complication rate was 3.8% (2/52), all small self-resolving pneumothoraces. CT-guided percutaneous biopsy is a safe diagnostic procedure with high diagnostic yield (77%) for anterior mediastinal lesions, highest for thymic neoplasms (100%), and can potentially obviate more invasive procedures.

  1. Clinical application of CT-guided percutaneous puncturing biopsy of subcarinal lymph node

    International Nuclear Information System (INIS)

    Yuan Xiaodong; Wang Jianhua; Zuo Changjing; Tian Jianming

    2011-01-01

    Objective: To discuss the safety and clinical significance of CT-guided percutaneous puncturing biopsy of subcarinal lymph node. Methods: During the period of July 2006-July 2010, CT-guided percutaneous puncturing biopsy of subcarinal lymph node was carried out in 17 patients (11 males and 6 females, with an average age of 54 years) with enlarged subcarinal lymph nodes. The clinical data were retrospectively analyzed. Immediately after the puncturing procedure was completed, CT scanning was performed to observe if there any complications and to evaluate the safety of puncturing biopsy. Biopsy specimens were sent for pathological examination to assess the puncturing accuracy and to make the pathologic diagnosis. The clinical usefulness of this technique was evaluated. Results: Of the total 17 cases, successful puncturing into the enlarged subcarinal lymph nodes with single procedure was achieved in 14 and sufficient tissue sample was obtained. The biopsy failed in three cases at initial puncturing procedure as the needle could not be placed into the enlarged subcarinal lymph nodes, the puncturing biopsy had to given up in two patients because of hemoptysis and in another patient the second puncturing biopsy performed one week later was successful. The total technical successful rate was 88.2% (15/17). Of the fifteen cases with successful puncturing, definitive pathological diagnosis was obtained in 13 and the diagnosis was uncertain in the remaining two, with a diagnosis positive rate of 86.7% (13/15). Pathologically, the diagnoses included metastatic lymphadenopathy from lung cancer (n=10), proliferative inflammatory lymphadenopathy (n=2) and tuberculous enlargement of lymph nodes (n=1). Complications occurred in 4 patients (23.5%, 4/17), which mainly were pneumothorax and pulmonary hemorrhage. Conclusion: With high successful rate and diagnostic accuracy, CT-guided percutaneous puncturing biopsy of subcarinal lymph node is a safe and effective technique if the

  2. Effectiveness of Fluoroscopic and US - Guided Percutaneous Catheter Drainage for Iliopsoas Abscess through the Anterolateral Transabdominal Approach

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Cheol; Shin, Tae Beom; Park, Mee Jung; Kim, Ji Eun; Choi, Hye Young; Bae, Kyung Soo; Choi, Dae Seob; Na, Jae Boem; Jeong, Seong Hoon [Gyeongsang National University Hospital, College of Medicine, Jinju (Korea, Republic of)

    2011-02-15

    We evaluated the effectiveness of performing fluoroscopic and ultrasonography guided percutaneous catheter drainage (PCD) through the anterolateral transabdominal approach for treating iliopsoas abscess. From January 2008 to December 2009, fluoroscopic and US-guided PCD through the anterolateral transabdominal approach was performed on sixteen iliopsoas abscesses of fourteen patients (7 males and 7 females; mean age: 63 years; age range: 30-87 years). Six abscesses were on the right side and ten abscesses were on the left side. The location of the abscesses were the psoas muscle (n=7), the iliacus muscle (n=7) and the iliopsoas muscle (n=2). All the procedures were performed under fluoroscopy and US guidance in the angiography room. The clinical findings before and after the procedure, the duration of catheter insertion and the procedure-related complications were evaluated. 15 out of the 16 iliopsoas abscesses were effectively treated. The duration of catheter insertion was 5- 27 days (mean: 14.6) days. No patient had significant complications during or after drainage. One patient died of uncontrolled diabetes complications and shock on the 9th day after percutaneous catheter drainage. One recurrence was noted 5 months after removal of the catheter. This patient underwent aspiration and antibiotic treatment for this lesion and the patient improved. Fluoroscopic and US-guided PCD for iliopsoas abscess through the anterolateral transabdominal approach is an effective and safe procedure

  3. [Percutaneous ultrasound-guided drainage in the surgical treatment of acute severe pancreatitis].

    Science.gov (United States)

    Delattre, J-F; Levy Chazal, N; Lubrano, D; Flament, J-B

    2004-11-01

    To report results of percutaneous ultrasound-guided drainage, performed by a surgeon, in the treatment of complications of acute pancreatitis (AP), and to determine the role of this technique in the therapeutic armamentarium of severe AP. From 1986 to 2001, 59 patients were included in this retrospective study. All patients initially had severe necrotizing AP (mean Ranson score = 4.1 ; range : 2-7). Anatomical lesions included pancreatic abscess in 6 patients and necrosis in 53 (17 stage D and 36 stage E according to Balthazar's classification). Necrosis was infected in 42 and sterile in 11 respectively. Drainage was performed under ultrasound guidance and local anaesthesia using small-diameter drains (7-14 French). Drainage was performed on average 23 days after onset of AP. Infection was proven by fine-needle aspiration in 47 (80 %) patients (41 infected necrosis and 6 localized abscess). In one patient, culture of aspirated fluid was negative but necrosis was infected (one false negative). Culture of aspirated fluid was negative and necrosis was sterile in 11 patients. Nineteen (32%) patients healed without subsequent surgery: 7 (16%) in the infected necrosis group, 6(55%) in the sterile necrosis group, and 6 (100%) in the abscess group. Forty (68%) patients had subsequent necrosectomy including 8 (14%) who died. Twenty (34 %) digestive fistulas healed spontaneously, except one treated by diversion stomia. Of the 16 (27 %) pancreatic fistulas, 6 needed subsequent interventional treatment. In selected patients, percutaneous drainage can represent an alternative to surgery with a 14% mortality rate. The high rate of subsequent necrosectomy suggests that drains with larger diameter, possibly associated with continuous irrigation, should be used.

  4. CT-guided percutaneous radiofrequency ablation of hepatic malignancies located in unusual regions under general anesthesia

    International Nuclear Information System (INIS)

    Pan Jie; Chen Shaohui; Lu Xin; Mao Yilei; Sang Xinting; Chen Fang; Li Yumei; Huang Yuguang; Jin Zhengyu

    2010-01-01

    Objective: To discuss the feasibility of CT-guided percutaneous radiofrequency ablation (RFA) of liver malignancies located in unusual regions under general anesthesia, and to assess its clinical value. Methods: Eighteen patients with a total of 26 malignant hepatic lesions were enrolled in this study. The lesions were located at diaphragmatic surface, hepatic hilum, hepatic subcapsular site,side of inferior vena cava, side of gallbladder or near by colon. Transcatheter arterial chemoembolization was performed in all patients, which was followed by CT-guided percutaneous RFA under general anesthesia. The time used for puncturing and the time used for putting the needles to the scheduled sites were recorded. A follow-up for 115 months was conducted. The complications and the therapeutic results were observed. Results: For all patients,the procedure of puncture and needle placement was completed in 1-3 minutes. A total of 35 RFA procedures were conducted for 26 lesions. No severe complications occurred. Complete necrosis was observed in 20 tumors and partial necrosis in 6 tumors. Conclusion: The result of this study indicates that CT-guided percutaneous RFA under general anesthesia is a feasible technique for the treatment of liver malignancies located at unusual regions. This technique is very helpful for reducing the manipulating difficulty and lowing the complication risk of RFA procedures. (authors)

  5. CT-guided percutaneous treatment of osteoid osteoma

    International Nuclear Information System (INIS)

    Mazoyer, J.F.; Kohler, R.; Bossard, D.

    1990-01-01

    The authors of this paper report seven cases of percutaneous destruction of osteoid osteoma. All patients complained of typical pain lasting for several months. In each case, finding of plain radiography, bone scintigraphy, and CT were strongly suggestive of an osteoid osteoma. All the lesions were located on the lower limb (five femoral and two tibial). Under general anesthesia, the nidus was drilled through a trocar inserted percutaneously with CT guidance. Patients were discharged 1-3 days after the procedure with no residual pain, and they are still asymptomatic 18-33 months later, with normal scintigraphic and CT studies. Histologic confirmation was allowed by technical improvement of the method in the last four cases

  6. Automatic path proposal computation for CT-guided percutaneous liver biopsy.

    Science.gov (United States)

    Helck, A; Schumann, C; Aumann, J; Thierfelder, K; Strobl, F F; Braunagel, M; Niethammer, M; Clevert, D A; Hoffmann, R T; Reiser, M; Sandner, T; Trumm, C

    2016-12-01

    To evaluate feasibility of automatic software-based path proposals for CT-guided percutaneous biopsies. Thirty-three patients (60 [Formula: see text] 12 years) referred for CT-guided biopsy of focal liver lesions were consecutively included. Pre-interventional CT and dedicated software (FraunhoferMeVis Pathfinder) were used for (semi)automatic segmentation of relevant structures. The software subsequently generated three path proposals in downward quality for CT-guided biopsy. Proposed needle paths were compared with consensus proposal of two experts (comparable, less suitable, not feasible). In case of comparable results, equivalent approach to software-based path proposal was used. Quality of segmentation process was evaluated (Likert scale, 1 [Formula: see text] best, 6 [Formula: see text] worst), and time for processing was registered. All biopsies were performed successfully without complications. In 91 % one of the three automatic path proposals was rated comparable to experts' proposal. None of the first proposals was rated not feasible, and 76 % were rated comparable to the experts' proposal. 7 % automatic path proposals were rated not feasible, all being second choice ([Formula: see text]) or third choice ([Formula: see text]). In 79 %, segmentation at least was good. Average total time for establishing automatic path proposal was 42 [Formula: see text] 9 s. Automatic software-based path proposal for CT-guided liver biopsies in the majority provides path proposals that are easy to establish and comparable to experts' insertion trajectories.

  7. Electromagnetic Navigational Bronchoscopy versus CT-guided Percutaneous Sampling of Peripheral Indeterminate Pulmonary Nodules: A Cohort Study.

    Science.gov (United States)

    Bhatt, Kavita M; Tandon, Yasmeen K; Graham, Ruffin; Lau, Charles T; Lempel, Jason K; Azok, Joseph T; Mazzone, Peter J; Schneider, Erika; Obuchowski, Nancy A; Bolen, Michael A

    2018-03-01

    Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P guided sampling (P guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.

  8. The diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Wang Hui; Zhang Fuchen; Ji Hongjian; Chen Liping

    2009-01-01

    Objective: To evaluate the diagnostic significance of CT-guided percutaneous transthoracic cutting needle biopsy for pulmonary lesions. Methods: The clinical data of CT-guided transthoracic cutting needle biopsy in 436 patients performed in past 10 years were retrospectively analyzed. Of 436 cases with pulmonary lesions, primary lung cancer was confirmed in 341, pulmonary metastasis in 62, non-malignant lesions in 33. The diagnostic accuracy and sensitivity were statistically analyzed. The occurrence of complications was discussed. Results: The diagnostic accuracy rate and sensitivity rate in primary lung cancer group were 94.7% and 94.1% respectively, in pulmonary metastasis group were 58.2% and 51.6% respectively and in non-malignant lesions group were 57.6% and 57.6% respectively. The successful rate of biopsy was 97.9%. The occurrence of complications was 15.6%. Conclusion: CT-guided percutaneous transthoracic cutting needle biopsy is a safe and valuable diagnostic technique with high diagnostic accuracy and less complications. It is very helpful in confirming the diagnosis in the patients with suspected primary pulmonary cancer, although the technical procedures need to be further improved for metastatic and non-malignant lung lesions. (authors)

  9. Clinical application of multi-detector CT-guided percutaneous coaxial biopsy for pulmonary lesions

    International Nuclear Information System (INIS)

    Jia Ningyang; Liu Shiyuan; Zhang Dianbo; Xiao Xiangsheng; Li Wentao; Li Chenzhou

    2008-01-01

    Objective: To evaluate the clinical application of multi-slice CT-guided percutaneous transthoracic lung coaxial-biopsy for pulmonary lesions. Methods: 152 times of 143 patients were performed with percutaneous transthoracic coaxial biopsy under multiple-slice CT-guidance. Analysis was carried out to investigate the diagnostic accuracy and the relationship between the size of the lesions for coaxial biopsy, together with the complications. Results: The diagnostic accuracy was 94.9% with specificity of 100%, including malignant tumors 116 cases (squamous cell cancer 48 cases, adenocarcinoma 34, small cell undifferentiated carcinoma 6, large cell carcinoma 4, bronchial alveolar carcinoma 8, metastatic carcinoma 16) and 19 cases of benign ones(TB 7 cases, inflammatory pseudotumor 9, hematoma 1, lung abscess 1). The size of lesion had a significant influence on the diagnostic accuracy. Conclusions: Percutaneous transthoracic coaxial lung biopsy is a safety method, possessing a high diagnostic accuracy. (authors)

  10. Percutaneous catheter drainage of intrapulmonary fluid collection

    International Nuclear Information System (INIS)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H.

    1994-01-01

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment

  11. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  12. CT-guided percutaneous cryoablation of osteoid osteoma in children: an initial study

    International Nuclear Information System (INIS)

    Wu, Bin; Xiao, Yue-Yong; Zhang, Xiao; Zhao, Lei; Carrino, John A.

    2011-01-01

    The purpose of this study was to evaluate the safety and efficacy of CT-guided percutaneous cryoablation for osteoid osteoma in children. This study was approved by the institutional ethics committee. From January 2007 to July 2008, six children (four boys, two girls, mean age 12.6 years old) with osteoid osteoma were treated with CT-guided percutaneous cryoablation. The procedures were carried out under conscious sedation and local anesthesia. CT guidance was used for procedural planning, instrument guidance, and monitoring. An argon-based cryoablation system was used. Each cryoablation included two freezing-thawing cycles. Follow-up was performed to assess technical and clinical outcome for a minimum of 12 months. A visual analog scale (VAS) was used to assess severity of pain pre- and post-procedure, and mean VAS for the group was compared pre- and post-procedure with a t-test. The mean clinical follow-up period was 28.7 months (ranging from 18 to 36 months). Cryoablation was technically and clinically successful for all patients. No major immediate or delayed complications were observed. Significant pain relief (P <0.05) was observed in all patients after operation. Mean VAS were 6.57 ± 0.55 pre-procedure and 0.57 ± 0.10 1 month post-procedure. Patients were allowed to fully bear their weight and function without limitation within 3 days after the procedure. Pain recurrence was not observed in any patient. Percutaneous cryoablation is safe and effective for the treatment of osteoid osteomas in children. Notably, this procedure can be accomplished without general anesthesia. (orig.)

  13. PERCUTANEOUS DRAINAGE : AN EFFECTIVE AND LESS AGRESSIVE APPROACH FOR COMPLICATED DIVERTICULAR ABSCESS

    Directory of Open Access Journals (Sweden)

    MOHAMADOU LAMINE GUEYE

    2017-10-01

    Full Text Available Retroperitoneal abscess is a serious complication of diverticular disease. Its management involves several options, ranging from conservative management to surgery. Elective colectomy is most often thought to be mandatory after a percutaneous drainage given the high rate of recidive. However, in patients with high risk for surgery, percutaneous drainage is often the main therapeutic alternative. We report a case of a 80-year-old woman, who was diagnosed to have a retroperitoneal abscess complicating a sigmoid diverticulitis. Ultrasound-guided percutaneous drainage allowed to drain 1500cc of pus and gas. The cytobacteriological examination was positive for: Streptococcus spp and Alkalescens dispar. The therapeutic outcomes were uneventful and despite we did not realize a colectomy because the patient was at high risk for surgery, there was no recidive after a 2-year-follow-up period. Percutaneous drainage can be a therapeutic alternative in patients with high risk for surgery in diverticular abscess of big size.

  14. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    Energy Technology Data Exchange (ETDEWEB)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A. [Heidelberg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology; Akbar, M. [Heidelberg Univ. (Germany). Dept. of Orthopaedic Surgery and Rehabilitation Medicine

    2016-12-15

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  15. CT-guided percutaneous spine biopsy in suspected infection or malignancy. A study of 214 patients

    International Nuclear Information System (INIS)

    Rehm, J.; Veith, S.; Kauczor, H.U.; Weber, M.A.; Akbar, M.

    2016-01-01

    To retrospectively determine the effectiveness and accuracy of CT-guided percutaneous biopsy of malignant and inflammatory bone lesions of the spine and to assess the reliability of pre-biopsy CT and MRI. 214 patients with lesions of the spine, which were suspicious either for being malignant or inflammatory, underwent CT-guided biopsy for pathological and/or microbiological detection. Biopsy samples were sent for histological examination in 128/214 patients, for microbiological analysis in 17/214 patients and for both analyses in 69/214 patients. Retrospectively, the diagnostic accuracy and sensitivity/specificity of the pre-interventional imaging (CT and MRI) were determined. In addition, the influence of the biopsy on subsequent patient management was assessed. The accuracy was 94.4% for histopathological analysis and 97.7% for microbiological analysis. In 25% of cases the microbiological analysis revealed an underlying pathogen that was not significantly affected by pre-biopsy antibiotic therapy. The sensitivity/specificity of the pre-biopsy cross-sectional imaging concerning suspected malignancy was 69%/78%. For suspected infection, the sensitivity/specificity of pre-biopsy imaging was 81%/44%. In 52% of all cases, the biopsy result changed subsequent patient management. Percutaneous CT-guided spine biopsy is a useful and reliable diagnostic procedure to establish a definitive diagnosis but with a relatively low yield of microorganisms in the case of infection.

  16. Percutaneous drainage of abdominal fluid collections that require laparotomy or relaparotomy with ultrasound guidance

    International Nuclear Information System (INIS)

    Miletic, D.; Topljak-Polic, D.; Uravic, M.; Fuckar, Z.; Glavas, R.

    2001-01-01

    Background. The aim of the study was to determine efficacy and reliability of percutaneous abdominal drainage in surgical patients and to evaluate intercostal approach to drain subphrenic collections. Material and methods. Eighty-seven patients aged from 29 to 84 years (mean, 55.5 years) were percutaneously drained under the sonographic guidance due to the postoperative or nonoperated abdominal collection that would otherwise require laparotomy. Intercostal, subcostal, lateral and anterior approach with eight to 14 French catheters were used to evacuate abdominal collection. Results. The intercostal approach was used to drain 31 (60.8%) of 51 subphrenic collections. The mean duration of drainage was independent of the intercostal or subcostal drainage route, but was significantly prolonged (p<0.05, Mann-Whitney U test) for purulent collections (median, 18 days; range 7-73 days) in comparison to hematomas, bilomas and other nonpurulent collections (median, 11 and 6 days, respectively). Sonographically guided percutaneous drainage was a definitive method in 92% patients, with 9.2% minor complications. Successful rate for subphrenic collections was even greater (96%). Conclusions. Sonographically guided percutaneous drainage is the method of choice in the treatment of abdominal collections that require laparotomy. If the puncture site is at least two intercostal spaces lower than the dome of diaphragm and catheter is not introduced through the pleural effusion, intercostal drainage is equally efficient and not less secure than subcostal approach. (author)

  17. Pleural space infections after image-guided percutaneous drainage of infected intraabdominal fluid collections: a retrospective single institution analysis.

    Science.gov (United States)

    Avella, Diego M; Toth, Jennifer W; Reed, Michael F; Gusani, Niraj J; Kimchi, Eric T; Mahraj, Rickeshvar P; Staveley-O'Carroll, Kevin F; Kaifi, Jussuf T

    2015-04-11

    Percutaneous drainage of infected intraabdominal fluid collections is preferred over surgical drainage due to lower morbidity and costs. However, it can be a challenging procedure and catheter insertion carries the potential to contaminate the pleural space from the abdomen. This retrospective analysis demonstrates the clinical and radiographic correlation between percutaneous drainage of infected intraabdominal collections and the development of iatrogenic pleural space infections. A retrospective single institution analysis of 550 consecutive percutaneous drainage procedures for intraabdominal fluid collections was performed over 24 months. Patient charts and imaging were reviewed with regard to pleural space infections that were attributed to percutaneous drain placements. Institutional review board approval was obtained for conduct of the study. 6/550 (1.1%) patients developed iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections. All 6 patients presented with respiratory symptoms and required pleural space drainage (either by needle aspiration or chest tube placement), 2 received intrapleural fibrinolytic therapy and 1 patient had to undergo surgical drainage. Pleural effusion cultures revealed same bacteria in both intraabdominal and pleural fluid in 3 (50%) cases. A video with a dynamic radiographic sequence demonstrating the contamination of the pleural space from percutaneous drainage of an infected intraabdominal collection is included. Iatrogenic pleural space infections after percutaneous drainage of intraabdominal fluid collections occur at a low incidence, but the pleural empyema can be progressive requiring prompt chest tube drainage, intrapleural fibrinolytic therapy or even surgery. Expertise in intraabdominal drain placements, awareness and early recognition of this complication is critical to minimize incidence, morbidity and mortality in these patients.

  18. CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.

    2013-01-01

    Aim: To assess the accuracy and risk factors for complications of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤20 mm) pulmonary lesions. Materials and methods: A retrospective study was undertaken comprising 169 patients who underwent CT-guided CNB for small (≤20 mm) pulmonary lesions. To assess the accuracy of the procedure, the diagnosis at biopsy was compared with the diagnosis after definitive surgery or clinical follow-up. The risk factors for pneumothorax and bleeding were determined by multivariate analysis of variables. Results: The overall diagnostic accuracy was 93.5%. The sensitivity for malignancy and specificity for benign lesions were 90.4% and 100%, respectively. Positive and negative predictive values were 100% and 83.3%, respectively. Twenty-five patients (14.8%) had pneumothorax after CT percutaneous CNB of the lung. The significant risk factors affecting the incidence of pneumothorax were lesion–pleural distance (p = 0.008) and needle–pleural angle (p = 0.012). The highest rate of pneumothorax correlated with a lesion–pleural distance ≥21 mm (OR = 18.46; 95%CI: 2.27–149.95) and a needle–pleural angle ≥51° (OR = 8.22; 95%CI: 2.14–31.49). Bleeding occurred in 30 patients (17.8%). The only significant risk factor affecting the incidence of bleeding was lesion–pleural distance (p = 0.011). The highest bleeding rate correlated with a lesion–pleural distance ≥21 mm (OR = 7.93; 95%CI: 1.73–36.43). Conclusion: CT-guided percutaneous CNB of small (≤20 mm) pulmonary lesions provides high diagnostic accuracy with acceptable complications. A lesion–pleural distance of ≥21 mm and needle–pleural angle of ≥51° are identified as the risk factors for highest pneumothorax rate. In addition, the needle–pleural angle is a novel predictor of pneumothorax. A lesion–pleural distance of ≥21 mm is also identified as a risk factor for the highest bleeding rate.

  19. Early mediastinal seroma secondary to modified Blalock-Taussig shunts - successful management by percutaneous drainage

    International Nuclear Information System (INIS)

    Connolly, Bairbre L.; Temple, Michael J.; Chait, Peter G.; Restrepo, Ricardo; Adatia, Ian

    2003-01-01

    Large symptomatic mediastinal seroma following modified-BT shunts, traditionally required revisional thoracotomy. We describe percutaneous image-guided pigtail catheter drainage in the successful treatment of early mediastinal seroma secondary to PTFE Blalock-Taussig shunt, avoiding thoracotomy. A retrospective review of all relevant clinical and imaging records in five patients was performed. All five presented with intermittent stridor, respiratory distress and/or episodic desaturation within 6 weeks of their surgery. In four of five infants, percutaneous drainage was effective and reoperation was avoided. In one of five, rather than urgent surgical evacuation and BT shunt revision, we were able to perform an elective stage-II bidirectional Glenn SVC-RA anastamosis in a stable infant. There were no complications. Percutaneous image-guided drainage of mediastinal seroma secondary to PTFE-BT shunt is a safe, minimally invasive, and effective treatment. This may avoid BT shunt revision. (orig.)

  20. Percutaneous catheter drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub [Catholic University Medical college, Seoul (Korea, Republic of)

    1993-09-15

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess.

  1. Percutaneous catheter drainage of lung abscess

    International Nuclear Information System (INIS)

    Kim, Young Shin; Chun, Kyung Ah; Choi, Hyo Sun; Ha, Hyun Kown; Shinn, Kyung Sub

    1993-01-01

    From March 1987 to July 1989, six patients (five adults and one child) with lung abscess (size, 5-13 cm in diameter) were treated with percutaneous aspiration and drainage. In each case, the puncture was made where the wall of the abscess was in contact with the pleural surface. An 8 to 10 Fr cartheter was inserted for drainage. Five of 6 had a dynamatic clinical response within 24 hours of the drainage. Percutaneous drainage was successful with complete abscess resolution in four and partial resolution in one patient. No response was seen in the rest one. The duration of drainage ranged from 7 to 18 days(average, 15.5 days) in successful cases. One case of the failure in drainage was due tio persistent aspiration of the neurologically impaired patient. In one patient, the abscess resolved after drainage but recurred after inadvertent removal of the catheter 7 days after insertion. In two patients, concurrent pleural empyema was resolved completely by the drainage. Computed tomography provide anatomic details necessary for choosing the puncture site and avoiding a puncture of the lung parenchyma. Percutaneous catheter drainage is safe and effective method for treating patient with lung abscess

  2. CT-guided percutaneous transthoracic aspiration biopsy of lung lesions: factors influencing the diagnostic accuracy

    International Nuclear Information System (INIS)

    Huang Zhenguo; Zhang Xuezhe; Wang Wu

    2006-01-01

    Objective: To investigate the factors influencing the diagnostic accuracy in CT-guided percutaneous transthoracic aspiration biopsy of lung lesions. Methods: CT-guided percutaneous transthoracic biopsy was performed in 435 patients with surgical pathologic confirmation or clinical follow-up. Univariant statistical analysis and multivariant stepwise Logistic regression analysis were used to study the influence of lesion-related factors (benignancy or malignancy, size, location, depth, presence of cavity), procedure factors (laser-guidance, position of patient) and patient-related factors (sex, age, presence of emphysema); with the accuracy of the diagnosis. Results: 1)289 lesions were diagnosed as malignant ones and 146 as benign ones. The accuracy of CT-guided biopsy was 83.4%(363/435). Univariant analysis showed that the diagnostic accuracies for malignant and benign lesions were 88.9%(257/289) and 72.6%(106/146), respectively (χ 2 =18.71, P=0.00002). Laser-group was superior to non-laser group (88.4% versus 80.9%, respectively, χ 2 =4.00, P=0.0456). Mean diameters of lesions in correct diagnostic group and non-correct diagnostic group were 3.78±1.64 cm and 3.02±1.26 cm, respectively (F=13.79, P=0.0002). 2)Multivariant stepwise Logistic regression analysis showed that among the various factors influencing the final benign or malignant diagnoses (Wald χ 2 =14.01, P=0.0002) and using laser-guidance(Wald χ 2 =3.92, P=0.0477) were significantly associated with the diagnostic accuracy. Conclusions: Final correct diagnoses (benign, malignant) are closely related to the application of laser-guidance for determining the diagnostic accuracy in CT-guided transcutaneous thoracic needle aspiration biopsy. (authors)

  3. Simple localization of peripheral pulmonary nodules - CT-guided percutaneous hook-wire localization

    International Nuclear Information System (INIS)

    Poretti, F.P.; Vorwerk, D.; Brunner, E.

    2002-01-01

    Background: Video-assisted thoracoscopic surgery (VATS) is an alternative approach to small intrapulmonary nodules, if transbronchial or percutaneous biopsy have failed. We investigated the feasibility and effectiveness of the percutaneous CT-guided placement of hook-wires to localize such nodules before video-assisted thoracoscopy. Subjects and Methods: 19 patients with new by diagnosed intrapulmonary nodules underwent CT-guided hook-wire localization by application of a X-Reidy-Set (Cook, Inc., Bjaeverskov, Denmark). The average age of the patient was 63 years (range: 19-80 years), the mean distance between the nodule and the pleura visceral was 7.58 mm (range: 0-25 mm) and the mean diameter was 11.58 mm (range: 5-25 mm). After localization, the patients underwent a VATS resection of the lesion within a mean time of 30 min (range 10-48 min). Results: In all cases, resection of the nodules was successful. In 4 older patients the marking was complicated by poor cooperability. At the end of manipulation the end of the hook was distanced from the nodule. But also in these cases, resection was successfully performed. 8 patients developed an asymptomatic pneumothorax: 5 of them in a minor (max. 1.5 cm rim), three of them in a moderate (max. 3 cm rim) dimension. In 4 patients, in whom the tumor was hit directly by the needle, local bleeding occurred. In one case, haemoptoe was present. In no patient did a dislocation of the hookwire-system occur. Conclusion: CT-guided placement of a hook-wire system is a simple and reasonable procedure which facilitates safe VATS resection of small pulmonary nodules. (orig.) [de

  4. Percutaneous drainage of chest abscesses in children

    International Nuclear Information System (INIS)

    Ball, W.S. Jr.; Towbin, R.B.; Bisset, G.S. III.

    1987-01-01

    Similar techniques for draining abdominal abscesses are now being applied to abscesses within the chest. This report describes the authors' experience in percutaneous drainage of seven chest abscesses in six children aged 3-13 years (mean, 7.3 years). Four pleural/extrapleural loculations were drained in three patients. Abscess location included right apex (one), right minor fissure (one), and left supradiaphragmatic (two). Collections resulted from esophageal perforation (two) or esophageal anastomotic leak (two). Three lung abscesses were drained in three patients. Abscess location included right lower, left lower, and right middle lobes. All lay adjacent to a pleural surface and were localized by CT or US before drainage. There were no complications. Complete resolution occurred in all six patients without the need for surgical intervention

  5. Ultrasound Guided Percutaneous Nephrostomy: Experience at ...

    African Journals Online (AJOL)

    Background: Obstructive uropathy is a common problem in urologic practice; temporary relief of obstruction in the upper tract poses a significant challenge. Ultrasound‑guided percutaneous nephrostomy (PCN) is an option for upper tract drainage; compared to fluoroscopic guidance, it is readily available, affordable, and not ...

  6. CT-guided percutaneous vertebroplasty for the treatment of metastases in the cervical spine

    International Nuclear Information System (INIS)

    Wang Jianhua; Wang Zhentang; Zuo Changjing; Shao Chenwei; Chen Wei; Lv Taozhen; Dong Aisheng

    2009-01-01

    Objective: To assess the clinical efficacy and complications of CT-guided percutaneous vertebroplasty in the treatment of metastases of the cervical spine, and to discuss the proper needle path for different cervical vertebra. Methods: CT-guided percutaneous vertebroplasty was performed in 17 patients with cervical vertebral metastatic neoplasm, and the results of the treatment were retrospectively analyzed. Close observation was carded out after the procedure and a follow-up of 3-17 months was conducted. A comparison of the visual analogue pain scale (VAS) and Frankel's classification between pre-and post- operation was made. The occurrence of complications was recorded. The optimal needle path was summarized. Results: (1) The successful puncture was achieved in all 17 cases. The needle pathway included: the front of carotid sheath (n=4), between carotid sheath and vertebral artery (n=11) and behind the vertebral artery and carotid sheath (n=2). (2) Before the procedure the VAS was 7.24 ± 1.01, and at the time of one hour, one week and three months after the procedure it was decreased to 3.24 ± 1.09, 2.40 ± 0.80 and 1.82 ± 0.53 respectively. Wilcoxon signed-rank test showed that the difference in VAS between pre-and post- operation was statistically significant (T=76.5, P 2 =4.52, P=0.033 and P<0.05 when Kruskal-Wallis test was adopted. (3) CT scanning immediately after the procedure showed that slight leakage of cement to the adjacent disc, epidural fat, parosteal tissue or to the needle path occurred in 35.3% with no serious complications. In a follow-up period of 3-17 months, the metastatic lesions remained stable in 14 cases (82.4%). Conclusion: (1) The optimal needle path for upper cervical vertebrae is posterolateral transpedicular approach while for the lower cervical vertebrae it is more reasonable to puncture via the front carotid sheath or between carotid sheath and vertebral artery. Nevertheless, the puncture pathway should be devised individually

  7. Percutaneous drainage of lung abscess

    Energy Technology Data Exchange (ETDEWEB)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik [Kyung-Pook National University Hospital, Daegu (Korea, Republic of)

    1992-05-15

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure.

  8. Percutaneous drainage of lung abscess

    International Nuclear Information System (INIS)

    Ri, Jong Min; Kim, Yong Joo; Kang, Duk Sik

    1992-01-01

    Medical treatment using antibiotics and postural drainage has been widely adopted as a treatment method of pulmonary abscess, accompanied by surgical methods in cases intractable to drug therapy. However long-term therapy may be required, and the tolerance of organisms to antibiotics or other complications are apt to be encountered, during medical treatment. To shorten the convalescent period or to decrease the risk of invasive procedures, rather simple and relatively easy interventional techniques such as transbronchial or percutaneous catheter drainage have been successfully tried. We have performed 12 cases of percutaneous drainages of lung abscesses under fluoroscope guidance. This report is on the results of this procedure

  9. CT-guided percutaneous ethanol injection in the treatment of thyroid adenoma

    International Nuclear Information System (INIS)

    Zheng Jiasheng; Zhao Xia; Cui Xiongwei; Li Hua

    2001-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous ethanol injection (CT-PEI) in the treatment of thyroid adenoma. Methods: Fifty-four patients with 73 nodules were included in the study. Thyroid adenoma was confirmed by pathology. The serum level T3, T4 and TSH were normal in all cases. CT-PEI (0.3-2.5 ml ethanol/cm 3 nodular tissue) was given for 115 times (mean 1.58 +- 0.78 times/nodule). Results: Complete cure was observed in 37 nodules (50.7%). In 28 nodules (38.3%) volume reduction was greater than 80%. A significant nodule reduction (50%-80%) was observed in 7 nodules. Only 1 (1.4%) nodule volume reduction was 28.9%. Apart from 1 case of transient dysphonia and 2 cases of mild pain and burning sensation, no side effect was observed. Conclusion: CT-PEI is a safe and effective therapeutic procedure with few side effects for thyroid adenoma

  10. Postoperative intraabdominal fluid collections : a modified percutaneous drainage method using a surgical drain track

    International Nuclear Information System (INIS)

    Lee, Deok Hee; Kim, Gab Choul; Hwang, Jae Cheol; Yoon, Hyun Ki; Song, Ho Young; Sung, Kyu Bo

    2000-01-01

    In the management of postoperative fluid collection, the conventional percutaneous drainage method can be employed. Because of abdominal incisions and various types of surgical drains and/or T-tubes, the application of this method is not always easy, however. We inserted a drainage catheter through a pre-existing percutaneous track formed by a surgical drain located adjacent to the site of abnormal fluid collection. There was no need to remove the drain nor make an additional puncture in the abdominal wall. A dilator was inserted along the drain, and a guide wire was used to negotiate its intraperitoneal track and reach the accumulated fluid. The procedure was simple and safe. We briefly describe our experience of this modified percutaneous drainage technique, as used in three cases involving postoperative fluid collection. (author)

  11. Percutaneous drainage treatment of primary liver abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.

    1989-02-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess.

  12. CT-guided percutaneous injection of the fibrin glue by 'double needle' technique for the treatment of sacral cysts

    International Nuclear Information System (INIS)

    Wang Ganggang; Chen Long; Yang Chao; Ni Caifang

    2013-01-01

    Objective: To analyze the efficacy and safety of CT-guided percutaneous injection of the fibrin glue by 'double needle' technique to treat sacral cyst. Methods: Clinical data of 20 cases with 'double-needle' injection of fibrin glue technology to treat sacral cyst were retrospectively analyzed. All patients had varying degrees of sacral nerve root compression symptoms. The treatment for sacral cyst was carried out after clear diagnosis was made. On the basis of CT-guided percutaneous injection of fibrin glue, the improved CT-guided percutaneous injection of fibrin glue by 'double-needle' technique was used to treat these patients. The average dose of fibrin glue was (5.9 ± 2.4) ml. The clinical results of improvement as to pain and neurological function were evaluated after follow-up of an average of 17 months. The assessment criteria were as follows: excellent, complete resolution of signs and symptoms, with the patient returning to his or her regular employment and no recurrence of cysts during 1 year of follow-up, good, symptoms and signs in the legs and perineal region resolved but with persistent pain in the lumbosacral region, which did not interfere with the patient's regular work (the cysts did not recur for 6 months during follow-up), fair, no improvement in clinical symptoms, but a decrease in cyst size on the imaging study, poor, no improvement in clinical symptoms and no observed changes in cyst size in imaging studies or recurrence. Results: Most patients experienced some degree of pain relief and functional improvement after fibrin glue therapy, with most experiencing complete or marked resolution of clinical symptoms. Nine patients reported excellent recovery, 8 reported good recovery, 2 reported fair recovery, and 1 reported poor recovery. The overall percentage of positive outcomes (excellent and good recovery) was 85%. No serious postoperative complications were discovered. Conclusions: CT guided percutaneous injection of the fibrin glue by

  13. Clinical application of percutaneous needling lung abscess drairnage under CT guidance

    International Nuclear Information System (INIS)

    Hu Xiaokun; Wang Mingyou; Li Chenjun; Lv Dongfang; Li Xiaodong; Yu Zhaocun

    2004-01-01

    Objective: To discuss the clinical application of drainage for lung abscess by needle puncture under CT guidance. Methods: 18 cases of lung abscess were drainaged by needle puncture under CT guidance, including direct aspiration by puncture needle 1-3 times (n=8) and retaining drainage tube continuously (n=10). Results: 17 cases with this procedure were succeeded possessing success rate of 94.7%(17/18). The patients were followed up for 11-35 days with symptom relieving better obviously and the focus shrinkage or disappeared (n=16), the curative rate reached 88.9%(16/18). The main complication was pneumothorax with capacities of 30%(n=1). Conclusions: The curative course of lung abscess can be shortened greatly by percutaneous needling drainage under CT guidance with mild trauma. The procedure is simple with high successful rate and less complication. (authors)

  14. Percutaneous drainage treatment of primary liver abscesses

    International Nuclear Information System (INIS)

    Berger, H.; Pratschke, E.; Berr, F.; Fink, U.; Klinikum Grosshadern, Muenchen; Klinikum Grosshadern, Muenchen

    1989-01-01

    28 primary liver abscesses, including 9 amoebic abscesses, in 24 patients were drained percutaneously. Indication for drainage in amoebic abscesses was imminent rupture and clinical symptoms as pleural effusion, lung atelectasis and pain. 95% of the primary abscesses were cured by percutaneous drainage and systemic antibiotic treatment. There was one recurrence of abscess, which was managed surgically. Reasons for drainage failure were: tumour necrosis and tumour perforation with secondary liver abscess. (orig.) [de

  15. Percutaneous drainage of abscesses associated with biliary fistulae

    International Nuclear Information System (INIS)

    Berger, H.; Winter, T.; Pratschke, E.; Sauerbruch, T.; Klinikum Grosshadern, Muenchen; Klinikum Grosshadern, Muenchen

    1989-01-01

    33 abdominal abscesses associated with fistulae in 31 patients were treated by percutaneous drainage. 19 of these patients had had surgery immediately preceding the drainage. In 64% the percutaneous drainage led to a diagnosis of an internal fistula. Additional therapeutic measures, because of the fistula, were necessary in 45% (operation, biliary drainage, repositioning of catheter). The average duration of drainage was 29 days. 77% of those abscesses which could be drained were treated successfully. Mortality in the entire series was 19%. (orig.) [de

  16. Percutaneous biliary drainage and stenting

    International Nuclear Information System (INIS)

    Totev, M.

    2012-01-01

    Full text: Percutaneous transhepatic cholangiography (PTC) is an X-ray or US guided procedure that involves the injection of a contrast material directly into the bile ducts inside the liver to produce pictures of them. If a blockage or narrowing is found, additional procedures may be performed: 1. insertion of a catheter to drain excess bile out of the body or both - internal and external; 2. plastic endoprothesis placement; 3. self-expandable metal stents placement to help open bile ducts or to bypass an obstruction and allow fluids to drain. Current percutaneous biliary interventions include percutaneous transhepatic cholangiography (PTC) and biliary drainage to manage benign and malignant obstructions. Internal biliary stents are either plastic or metallic, and various types of each kind are available. Internal biliary stents have several advantages. An external tube can be uncomfortable and have a psychological disadvantage. An internal stent prevents the problems related to external catheters, for example, pericatheter leakage of bile and the need for daily flushing. The disadvantages include having to perform endoscopic retrograde cholangiopancreatography (ERCP) or new PTC procedures to obtain access in case of stent obstruction. Better patency rates are reported with metallic than with plastic stents in cases of malignant obstruction, though no effect on survival is noted. Plastic internal stents are the cheapest but reportedly prone to migration. Metallic stents are generally not used in the treatment of benign disease because studies have shown poor long-term patency rates. Limited applications may include the treatment of patients who are poor surgical candidates or of those in whom surgical treatment fails. Most postoperative strictures are treated surgically, though endoscopic and (less commonly) percutaneous placement of nonmetallic stents has increasingly been used in the past few years. Now there are some reports about use of biodegradable biliary

  17. Performance of a New Blunt-Tip Coaxial Needle for Percutaneous Biopsy and Drainage of "Hard-To-Reach" Targets.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Caudrelier, Jean; Bauones, Salem; Tsoumakidou, Georgia; Koch, Guillaume; Gangi, Afshin

    2017-09-01

    To present a new blunt-tip coaxial needle (SoftGuard) applied to access "hard-to-reach" targets undergoing percutaneous image-guided biopsy or drainage. All consecutive patients presenting between August and December 2016 with "hard-to-reach" (blunt-tip needle is a safe and effective tool when applied as a coaxial working cannula for percutaneous biopsy or drainage of "hard-to-reach" targets.

  18. Application of CT-guided percutaneous thyroid biopsy in basic study of interventional therapy for Graves disease

    International Nuclear Information System (INIS)

    Yi Genfa; Zhao Wei; Hu Jihong; Jin Cangzheng; Yang Huiying

    2007-01-01

    Objective: To evaluate the value of application of CT-guided percutaneous thyroid biopsy in basic study of interventional treatment for Graves disease. Methods: Fifteen patients of hyperthyroidism caused by Graves' disease had been undertaken transcathter arterial embolizsation with PVA micropheres including 52 core needle biopsy(CNB)of pre-or post-interventional procedure. All procedures were divided into 2 groups according to the size of the thyroid enlargement: (1) II degree enlargement (n=19)under palpation puncture. (2) No enlargement or under II degree enlargement (n=33)with palpation and CT-guided puncture. Results: In group (1), 17 of the 19 procedures with palpation puncture were succeeded, reaching a successful rate of 89.5%. For group (2), the successful rate of CT-guided puncture was 91.7%. The difference between the successful rate of two groups showed statistical significance (P<0.05). No complication occurred during procedures in all cases. Conclusions: CT-guided thyroid core needle biopsy is an accurate, safe and high successful procedure providing the basic study for post-interventional treatment of Graves disease. (authors)

  19. CT-guided percutaneous acetic acid injection therapy for liver metastasis

    International Nuclear Information System (INIS)

    Yu Tongfu; Wang Dehang; Zhuang Zhenwu; Li Linxun; Shi Haibin

    2002-01-01

    Objective: To evaluate the efficacy of CT-guided percutaneous acetic acid injection (PAI) for liver metastasis. Methods: Thirty-five cases (40 lesions) with liver metastasis were treated with PAI. 4-10 ml of 30% acetic acid with 1 ml contrast media was injected into every lesion. PAI was performed twice a week, and repeated for 2 to 3 weeks. Results: The tumors shrunk in 23 lesions, and remained unchanged in 12 lesions. The efficiency was 87.5%. All cases were followed up for 3 months to 3 years. One year survival rates was 62.9% (22 cases), 2 years 40.0% (14 cases), and 3 years 22.9% (8 cases). Conclusion: PAI was an effective therapy for liver metastasis

  20. CT-Guided Drainage of Pericardial Effusion after Open Cardiac Surgery.

    Science.gov (United States)

    Nour-Eldin, Nour-Eldin Abdelrehim; Alsubhi, Mohammed; Gruber-Rouh, Tatjana; Vogl, Thomas J; Kaltenbach, Benjamin; Soliman, Hazem Hamed; Hassan, Wael Eman; Abolyazid, Sherif Maher; Naguib, Nagy N

    2017-08-01

    This study was designed to evaluate the safety and efficacy of CT-guided drainage of the pericardial effusion in patients after cardiac surgery. The study included 128 consecutive patients (82 males, 46 females; mean age 66.6 years, SD: 4.2) complicated by pericardial effusion or hemopericardium after cardiac surgeries between June 2008 and June 2016. The medical indication for therapeutic pericardiocentesis in all patients was hemodynamic instability caused by pericardial effusion. The treatment criteria for intervention were evidence of pericardial tamponade with ejection fraction (EF) effusion was 260 ml (range 80-900 ml; standard deviation [SD]: ±70). Directly after pericardiocentesis, there was a significant improvement of the ejection fraction to 40-55% (mean: 45%; SD: ±5; p effusion drainage was 10%. The drainage was applied anteriorly (preventricular) in 39 of 128 (30.5%), retroventricularly in 33 of 128 (25.8%), and infracardiac in 56 of 128 (43.8%). Recurrence rate of pericardial effusion after removal of drains was 4.7% (67/128). Complete drainage was achieved in retroventricular and infracardiac positioning of the catheter (p effusion is a minimally invasive technique for the release of the tamponade effect of the effusion and improvement of cardiac output.

  1. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-11-15

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  2. CT-Guided Percutaneous Transthoracic Localization of Pulmonary Nodules Prior to Video-Assisted Thoracoscopic Surgery Using Barium Suspension

    International Nuclear Information System (INIS)

    Lee, Nyoung Keun; Park, Chang Min; Kang, Chang Hyun; Jeon, Yoon Kyung; Choo, Ji Yung; Lee, Hyun Ju; Goo, Jin Mo

    2012-01-01

    To describe our initial experience with CT-guided percutaneous barium marking for the localization of small pulmonary nodules prior to video-assisted thoracoscopic surgery (VATS). From October 2010 to April 2011, 10 consecutive patients (4 men and 6 women; mean age, 60 years) underwent CT-guided percutaneous barium marking for the localization of 10 small pulmonary nodules (mean size, 7.6 mm; range, 3-14 mm): 6 pure ground-glass nodules, 3 part-solid nodules, and 1 solid nodule. A 140% barium sulfate suspension (mean amount, 0.2 mL; range, 0.15-0.25 mL) was injected around the nodules with a 21-gauge needle. The technical details, surgical findings and pathologic features associated with barium localizations were evaluated. All nodules were marked within 3 mm (mean distance, 1.1 mm; range, 0-3 mm) from the barium ball (mean diameter, 9.6 mm; range, 8-16 mm) formed by the injected barium suspension. Pneumothorax occurred in two cases, for which one needed aspiration. However, there were no other complications. All barium balls were palpable during VATS and visible on intraoperative fluoroscopy, and were completely resected. Both the whitish barium balls and target nodules were identifiable in the frozen specimens. Pathology revealed one invasive adenocarcinoma, five adenocarcinoma-in-situ, two atypical adenomatous hyperplasias, and two benign lesions. In all cases, there were acute inflammations around the barium balls which did not hamper the histological diagnosis of the nodules. CT-guided percutaneous barium marking can be an effective, convenient and safe pre-operative localization procedure prior to VATS, enabling accurate resection and diagnosis of small or faint pulmonary nodules.

  3. Transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma located in the subphrenic region of liver

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    2000-01-01

    The purpose of this study is to evaluate the feasibility of transpulmonary CT-guided percutaneous ethanol injection therapy (CT-PEIT) for hepatocellular carcinoma (HCC, 15 lesions) located in the subphrenic region and untreatable by ultrasonography-guided PEIT. The HCC was localized on Lipiodol CT image with a graduated grid system. We advanced a PEIT needle in a stepwise fashion, perpendicularly to the major axis of body through the lung with intermittent localization scans to position the tip of the needle in the lesion. Ethanol was injected with monitoring scans obtained after incremental volumes of injection, until perfusion was judged to be complete. A total of 20 CT-PEIT sessions were performed. The average number of needles passed from skin to liver in each CT-PEIT session was 2.7, the average volume of ethanol injected was 11.7 ml, and the average time required was 53.6 minutes. Complete perfusion of the lesion by ethanol was achieved in all lesions with only a single or double CT-PEIT procedure without severe complications. Local recurrence was detected in 3 to 15 followed up lesions for 14 months on average. In conclusion, transpulmonary CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC located in the subphrenic region. (author)

  4. Percutaneous drainage in conservative therapy for perforated gastroduodenal ulcers.

    Science.gov (United States)

    Oida, Takatsugu; Kano, Hisao; Mimatsu, Kenji; Kawasaki, Atsushi; Kuboi, Youichi; Fukino, Nobutada; Kida, Kazutoshi; Amano, Sadao

    2012-01-01

    The management of peptic ulcers has dramatically changed and the incidence of elective surgery for gastroduodenal peptic ulcers has markedly decreased; hence, the incidence of emergency surgery for perforated peptic ulcers has slightly increased. In select cases, conservative therapy can be used as an alternative for treating perforated gastroduodenal ulcers. In this study, we evaluated the efficacy of percutaneous abdominal drainage for the conservative treatment of perforated gastroduodenal ulcers. We retrospectively studied 51 patients who had undergone conservative therapy for perforated gastroduodenal ulcers. These patients were divided into 2 groups on the basis of the initial treatment with conservative therapy with or without percutaneous drainage: group PD included patients who had undergone percutaneous drainage and group NPD, patients who had undergone non-percutaneous drainage. In the PD group, 14.3% (n=3) of the patients did not respond to conservative therapy, while this value was 43.3% (n=13) in the NPD group. The 2 groups differed significantly with respect to conversion from conservative therapy to surgery (pperforated gastroduodenal ulcers should be performed only in the case of patients meeting the required criteria; its combination with percutaneous intraperitoneal drainage is effective as initial conservative therapy.

  5. Posterior pelvic ring fractures: Closed reduction and percutaneous CT-guided sacroiliac screw fixation

    International Nuclear Information System (INIS)

    Jacob, Augustinus Ludwig; Messmer, Peter; Stock, Klaus-Wilhelm; Suhm, Norbert; Baumann, Bernard; Regazzoni, Pietro; Steinbrich, Wolfgang

    1997-01-01

    Purpose. To assess the midterm results of closed reduction and percutaneous fixation (CRPF) with computed tomography (CT)-guided sacroiliac screw fixation in longitudinal posterior pelvic ring fractures. Methods. Thirteen patients with 15 fractures were treated. Eleven patients received a unilateral, two a bilateral, screw fixation. Twenty-seven screws were implanted. Continuous on-table traction was used in six cases. Mean radiological follow-up was 13 months. Results. Twenty-five (93%) screws were placed correctly. There was no impingement of screws on neurovascular structures. Union occurred in 12 (80%), delayed union in 2 (13%), and nonunion in 1 of 15 (7%) fractures. There was one screw breakage and two axial dislocations. Conclusion. Sacroiliac CRPF of longitudinal fractures of the posterior pelvic ring is technically simple, minimally invasive, well localized, and stable. It should be done by an interventional/surgical team. CT is an excellent guiding modality. Closed reduction may be a problem and succeeds best when performed as early as possible

  6. [Clinical value of CT-guided high frequency-induced thermotherapy as a treatment for intrahepatic cholangiocarcinoma].

    Science.gov (United States)

    Fan, Wei-Jun; Zhang, Liang; Gu, Yang-Kui; Wang, Li-Gang; Ouyang, Yu-Shu

    2008-07-01

    To evaluate the therapeutic effect of CT-guided high frequency-induced thermotherapy (HiTT) for intrahepatic cholangiocarcinoma. Seventeen patients of intrahepatic cholangiocarcinoma with 21 lesions underwent comprehensive treatment with HiTT as the principle approach. As to the patients with obstructive jaundice, percutaneous trans-hepatic cholangial drainage (PTCD) or bile duct endoprosthesis placement was performed first to improve the liver function, then HiTT was performed; and patients without obstructive jaundice underwent CT-guided HiTT directly, 1-2 weeks later, chemotherapy was given for 4 - 6 courses. CT scan 1 week after HiTT showed a short-term achievement rate of 100% (17/17), and the single puncture in situ ablation rate was 76.1% (16/21). The average life span in the near future was 13.5 months. The adverse effects included topo-bleeding, pain after procedure, liver function damage, defervescence, etc. All the patients recovered after symptomatic treatment. The clinical value of CT-guided HiTT for intrahepatic cholangiocarcinoma is obvious.

  7. Percutaneous drainage of fluid collection in the pleural and pericardial spaces. Perkutan pleura- og perikarddrenasje

    Energy Technology Data Exchange (ETDEWEB)

    Drolsum, A.; Skjennald, A. (Ullevaal sykehus, Oslo (Norway))

    1994-11-01

    Both MRI, CT and sonography will give a good presentation of fluid collection in pleura and pericardium. Sonography is the ideal imaging method for monitoring interventional procedures. Its ability to visualize superficial fluid collection and its real-time capability allows precise control of needle and catheter insertions. If the abnormality is poorly seen with ultrasound, often because of air in the collection, CT can be used as a guidance system. Diagnostic thoracocentesis and pericardiocentesis are performed mainly to exclude malignancy and infections, and the punctions are made with small needles. Therapeutic thoracocentesis is usually performed to relieve dyspnoe and small catheters are used. Drainage of empyema is performed with larger catheters because of the high viscosity of the infected fluid. Patients with threatening cardiac tamponade will often respond immediately to drainage of the pericardial space by catheter. These procedures can be done with local anesthesia only. If complications occur, it is mainly the pneumothorax that has to be treated. This can be managed directly under the procedure as the drainage catheter is attached to continuous pleural suction, or a catheter can be inserted in the pleural space after diagnostic punction. Patients with coagulation abnormalities must be evaluated especially before any intervention, otherwise there are no contraindications for these image-guided percutaneous procedures. 14 refs., 6 figs.

  8. Percutaneous CT-guided biopsy of the musculoskeletal system: Results of 2027 cases

    International Nuclear Information System (INIS)

    Rimondi, Eugenio; Rossi, Giuseppe; Bartalena, Tommaso; Ciminari, Rosanna; Alberghini, Marco; Ruggieri, Pietro; Errani, Costantino; Angelini, Andrea; Calabro, Teresa; Abati, Caterina Novella; Balladelli, Alba; Tranfaglia, Cristina; Mavrogenis, Andreas F.; Vanel, Daniel; Mercuri, Mario

    2011-01-01

    Introduction: Biopsy of the musculoskeletal system is useful in the management of bone lesions particularly in oncology but they are often challenging procedures with a significant risk of complications. Computed tomography (CT)-guided needle biopsies may decrease these risks but doubts still exist about their diagnostic accuracy. This retrospective analysis of the experience of a single institution with percutaneous CT-guided biopsy of musculoskeletal lesions evaluates the results of these biopsies for bone lesions either in the appendicular skeleton or in the spine, and defines indications. Materials and methods: We reviewed the results of 2027 core needle biopsies performed over the past 18 years at the authors' institution. The results obtained are subject of this paper. Results: In 1567 cases the correct diagnosis was made with the first CT-guided needle biopsy (77.3% accuracy rate), in 408 cases the sample was not diagnostic and in 52 inadequate. Within 30 days these 408 patients underwent another biopsy, which was diagnostic in 340 cases with a final diagnostic accuracy of 94%. Highest accuracy rates were obtained in primary and secondary malignant lesions. Most false negative results were found in cervical lesions and in benign, pseudotumoral, flogistic, and systemic pathologies. There were 22 complications (18 transient paresis, 3 haematomas, 1 retroperitoneal haematoma) which had no influence on the treatment strategy, nor on patient outcome. Conclusion: This technique is reliable and safe and should be considered nowadays the gold standard for biopsies of the musculoskeletal system.

  9. Treatment of aneurysmal bone cysts by percutaneous CT-guided injection of calcitonin and steroid

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Kattapuram, Susan V.; Huang, Ambrose J.; Simeone, F.J.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital, Department of Radiology Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States)

    2017-01-15

    To determine the efficacy and safety of percutaneous calcitonin and steroid injection in the treatment of aneurysmal bone cysts (ABCs). Our study was IRB-approved and HIPAA-compliant. We reviewed pre- and post-procedural imaging studies and medical records of all CT-guided percutaneous injections of ABCs with calcitonin and steroid performed at our institution between 2003 and 2015. Treatment success based on imaging was categorized as substantial (51-100 %), partial (1-50 %), or none (0 %) by comparing radiographs of the lesion before and after treatment. Our study group comprised 9 patients (7 female, 2 male; mean age 19 ± 5 (range 12-25) years). ABCs were located in the pubis (n = 3), femur (n = 2), and humerus/scapula/ilium/sacrum (n = 1 for each). One patient did not have any clinical or imaging follow-up. For the other 8 patients, clinical and imaging follow-up ranged from 1 to 93 months (mean 16 ± 29 months). One patient had two injections, and 1 patient had three injections. Six out of eight patients (75 %) had complete symptomatic relief and 2 patients (25 %) had partial symptomatic relief after initial injection. Imaging follow-up revealed substantial imaging response in 4 out of 8 patients (50 %). There was a partial imaging response in 2 patients (25 %) and no imaging response in 2 out of 8 patients (25 %), and all 4 of these patients had local recurrence. There were no complications. Percutaneous CT-guided injection of ABCs with calcitonin and steroid is a safe and effective treatment. Lack of imaging response may necessitate more aggressive treatment to minimize local recurrence. (orig.)

  10. Percutaneous targeted argon-helium cryoablation for renal carcinoma under CT guidance

    International Nuclear Information System (INIS)

    Xu Jian; Cao Jianmin; Lu Guangming; Shi Donghong; Kong Weidong; Gao Dazhi

    2008-01-01

    Objective: To establish initially the technique and evaluate the principle, safety and short term efficacy of argon-helium superconductor operation system (or Ar-He knife) targeted cryotherapy for renal carcinoma. Methods: Seven patients with renal carcinoma were treated with CT-guided percutaneous Ar-He knife targeted cryotherapy. Results: After cryotherapy, no serious complications, such as bleeding, skin cold injury, infection, implantation metastasis inside the puncture path occurred, and one month later, CT scans showed low-density local necrosis in all tumors of the 7 cases, but the tumor reduction in size was found only in 2 cases. Conclusion: CT guiding percutaneous Ar-He knife targeted cryoablation for renal carcinoma is a safe, effective and minimally invasive therapeutic method, particularly for inoperable cases. (authors)

  11. Percutaneous drainage of lung abscesses

    International Nuclear Information System (INIS)

    van Sonnenberg, E.; D'Agostino, H.; Casola, G.; Vatney, R.R.; Wittich, G.R.; Harker, C.

    1989-01-01

    The authors performed percutaneous drainage of lung abscesses in 12 patients. Indications for drainage were septicemia and persistence or worsening of radiographic findings. These lung abscesses were refractory to intravenous antibiotics and to bronchial toilet. Etiology of the abscesses included pneumonia (most frequently), trauma, postoperative development, infected necrotic neoplasm, and infected sequestration. Guidelines for drainage included passage of the catheter through contiguously abnormal lung and pleura, inability of the patient to cough, and/or bronchial obstruction precluding bronchial drainage. Cure was achieved in 11 of 12 patients. Catheters were removed on an average of 16 days after insertion. Antibiotics were administered an average of 18 days before drainage. No major complications occurred

  12. Percutaneous CT-guided biopsy for lung lesions 1 cm or smaller: the technique, results and complication

    International Nuclear Information System (INIS)

    Song, Chi Sung

    2006-01-01

    The author wanted to assess the diagnostic accuracy and safety of percutaneous biopsy for lung lesions 1 cm or smaller; the biopsies were performed on the basis of the modified coaxial technique under CT guidance. Thirty-five patients (22 men and 13 women) 23-76 years old (average age: 56.8 years) with lung lesions 1 cm or smaller underwent CT-guided percutaneous biopsy. Fifteen patients had underlying primary malignancies. After an 18 G guiding cannula was introduced to the border of the small lung lesion via the modified coaxial technique, fine-needle aspiration biopsy with 21 G needle and core tissue biopsies with 19.5 G or 20 G biopsy guns were performed through the lumen of the guiding cannula. The core tissue biopsies were finished after 6 macroscopic core tissue specimens were obtained. When the needle hit the eccentric portion of the small lung lesion, a 'fanning-out' technique with using the guiding cannula was applied to get multiple core tissue specimens from the small lung lesion. The diagnostic accuracy of this method was evaluated and the complications were reviewed. Both the cytopathologic and histopathologic specimens were obtained in all 35 cases. The fanning-out technique was necessary in 15 cases (43%) for obtaining six core tissue specimens from small lesions. The final diagnoses were 17 malignant lesions and 18 benign lesions. Sixteen lesions were true-positive, eighteen were true-negative, none was false-positive and one was false-negative. The overall diagnostic accuracy was 97%. The sensitivity for detecting malignancy and the specificity for benign lesion were 94% and 100%, respectively. The positive and negative predictive values were 100% and 95%, respectively. The diagnostic ability to characterize the specific cell type of the malignant lesion was 94% (16 of 17), that for the benign lesions was 83% (15 of 18), and overall diagnostic ability was 89% (31 of 35). Five patients (14%) developed a pneumopthorax, and one of them (3%) received

  13. Percutaneous drainage with ultrasound guidance in the intensive care unit

    International Nuclear Information System (INIS)

    Kang, Doo Kyung; Won, Je Hwan; Kim, Jai Keun; Lee, Kwang Hun; Kim, Ji Hyung

    2004-01-01

    To determine the efficacy and safety of bedside percutaneous drainage procedures with ultrasound guidance in critically ill patients in the intensive care unit (ICU). Sixty five percutaneous drainage procedures performed at the bedside, in 39 ICU patients, were evaluated. All of the procedures were performed with ultrasound guidance alone. The procedures consisted of percutaneous drainage of abdominal (n=35) and pleural (n=27) fluids, percutaneous cholecystostomy (n=2) and percutaneous nephrostomy (n=1). The clinical responses were classified as 'complete response', 'partial response', 'failure' or 'undetermined'. The medical records were reviewed retrospectively to evaluate the clinical response. Technical success was achieved in 64 of the 65 procedures (98.5%). The complication rate was 13.8% (9 cases). There was no immediate procedure-related death or worsening of the clinical condition of the patients. The clinical responses after drainage were 'complete response' in 39 cases (60.9%). 'partial response' in 14 (21.9%), 'failure' in 3 (4.7%), and 'undetermined' in 8 (12.5%). Bedside drainage procedures with ultrasound guidance are effective and safe to perform when patients are too critically ill to be moved from the ICU to the angiography room

  14. CT fluoroscopy-guided percutaneous gastrostomy with loop gastropexy and peel-away sheath trocar technique in 31 amyotrophic lateral sclerosis patients

    Energy Technology Data Exchange (ETDEWEB)

    De Bucourt, Maximilian; Collettini, Federico; Althoff, Christian; Streitparth, Florian; Greupner, Johannes; Hamm, Bernd (Dept. of Radiology, Charite - Univ. Medicine, Berlin (Germany)), Email: mdb@charite.de; Teichgraeber, U.K. (Dept. of Radiology, Jena Univ. (Germany))

    2012-04-15

    Background: In amyotrophic lateral sclerosis (ALS) patients with respiratory impairment and/or advanced disease, performing even mild sedation - as is usually necessary for percutaneous endoscopic gastrostomy (PEG) placements - is fraught with risk. These patients are often referred to Interventional Radiology for alternative percutaneous gastrostomy tube placement options. Purpose: To report our experience with CT fluoroscopy-guided percutaneous gastrostomy with a novel loop gastropexy and peel-away sheath trocar technique in ALS patients as an alternative to endoscopic techniques. Material and Methods: A consecutive series of 31 amyotrophic lateral sclerosis patients in whom endoscopic gastrostomy was considered too dangerous or impossible to perform underwent CT-guided percutaneous gastropexy and gastrostomy and prospective follow-up. All procedures were performed with a 15 FR Freka Pexact gastrostomy kit, a 16-row CT scanner (Aquilion 16) and single shot CT fluoroscopy mode. Results: The procedure was performed successfully in 30 of 31 patients (20 men, 11 women; median age 60 years, range 38-80 years). In the remaining case the stomach was punctured under CT fluoroscopy and CO2 insufflation was initiated thereafter, leading to successful gastrostomy without prior gastropexy and without further adverse events during follow-up. Two patients reported unproblematic exchange of a balloon tube due to skin irritations with no further adverse events. One patient reported accidental displacement of an exchanged new balloon tube in domestic environment due to balloon leakage: A new balloon tube was easily re-inserted in a hospital the same day. No serious adverse events such as peritonitis, persistent local bleeding, systemic blood loss, or any local infection requiring surgical intervention were observed. Until August 11, 2011 follow-up resulted in 7473 cumulative gastrostomy-days from the date of first placement. Conclusion: Initial results suggest that the described

  15. CT fluoroscopy-guided percutaneous gastrostomy with loop gastropexy and peel-away sheath trocar technique in 31 amyotrophic lateral sclerosis patients

    International Nuclear Information System (INIS)

    De Bucourt, Maximilian; Collettini, Federico; Althoff, Christian; Streitparth, Florian; Greupner, Johannes; Hamm, Bernd; Teichgraeber, U.K.

    2012-01-01

    Background: In amyotrophic lateral sclerosis (ALS) patients with respiratory impairment and/or advanced disease, performing even mild sedation - as is usually necessary for percutaneous endoscopic gastrostomy (PEG) placements - is fraught with risk. These patients are often referred to Interventional Radiology for alternative percutaneous gastrostomy tube placement options. Purpose: To report our experience with CT fluoroscopy-guided percutaneous gastrostomy with a novel loop gastropexy and peel-away sheath trocar technique in ALS patients as an alternative to endoscopic techniques. Material and Methods: A consecutive series of 31 amyotrophic lateral sclerosis patients in whom endoscopic gastrostomy was considered too dangerous or impossible to perform underwent CT-guided percutaneous gastropexy and gastrostomy and prospective follow-up. All procedures were performed with a 15 FR Freka Pexact gastrostomy kit, a 16-row CT scanner (Aquilion 16) and single shot CT fluoroscopy mode. Results: The procedure was performed successfully in 30 of 31 patients (20 men, 11 women; median age 60 years, range 38-80 years). In the remaining case the stomach was punctured under CT fluoroscopy and CO2 insufflation was initiated thereafter, leading to successful gastrostomy without prior gastropexy and without further adverse events during follow-up. Two patients reported unproblematic exchange of a balloon tube due to skin irritations with no further adverse events. One patient reported accidental displacement of an exchanged new balloon tube in domestic environment due to balloon leakage: A new balloon tube was easily re-inserted in a hospital the same day. No serious adverse events such as peritonitis, persistent local bleeding, systemic blood loss, or any local infection requiring surgical intervention were observed. Until August 11, 2011 follow-up resulted in 7473 cumulative gastrostomy-days from the date of first placement. Conclusion: Initial results suggest that the described

  16. Application of C-arm CT-guided targeted puncturing technique in performing non-vascular interventional biopsy or interventional therapy

    International Nuclear Information System (INIS)

    Li Zhen; Han Xinwei; Jiao Dechao; Ren Jianzhuang; Su Yu; Ye Hui

    2011-01-01

    Objective: to investigate the clinical value of C-arm CT-guided targeted puncturing technique in performing non, vascular interventional biopsy or interventional therapy. Methods: Thirty, one patients, who were encountered in authors' hospital during the period from July 2010 to September 2010, were involved in this study. C-arm CT-guided percutaneous targeted puncturing biopsy or interventional therapy was performed in all 31 patients. All patients had complete clinical data. The complications and positive rate of biopsy were recorded and analyzed. Results: Under C-arm CT-guidance, percutaneous interventional therapy was carried out in 13 patients. The interventional procedures included radiofrequency ablation therapy for hepatic cellular carcinoma (n=2), pelvic abscess draining (n=1), hepatic abscess draining (n=1), ethanol injection for liver cancer (n=4), sclerotic therapy with ethanol injection for renal cyst (n=2), sclerotic therapy with ethanol injection for liver cyst (n=2) and catheter-indwelling drainage for pancreatic pseudocyst (n=1). percutaneous interventional biopsy was performed in the remaining 18 cases, including liver (n=4), lung (n=7), mediastinum (n=2), bone and soft tissue (n=4) and neck mass (n=1). All the procedures were successfully accomplished, no technique, related complications occurred during the operation. For biopsy examination in 18 cases, the positive rate was 94.4% (17/18) and false, negative results was seen in one case with lung lesion. Conclusion: The percutaneous targeted puncturing technique with C, arm CT-guidance combines the advantages of both CT scanning and fluoroscopy. The use of real, time road, mapping function can effectively guide the puncturing and therapeutic management, which can not only optimize the workflow, save the operation time, but also improve the success rate and technical safety. Therefore, it is of great value to popularize this targeted puncturing technique. (authors)

  17. PET/CT-guided percutaneous liver mass biopsies and ablations: Targeting accuracy of a single 20 s breath-hold PET acquisition

    International Nuclear Information System (INIS)

    Shyn, P.B.; Tatli, S.; Sahni, V.A.; Sadow, C.A.; Forgione, K.; Mauri, G.; Morrison, P.R.; Catalano, P.J.; Silverman, S.G.

    2014-01-01

    Aim: To determine whether a single 20 s breath-hold positron-emission tomography (PET) acquisition obtained during combined PET/computed tomography (CT)-guided percutaneous liver biopsy or ablation procedures has the potential to target 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG)-avid liver masses as accurately as up to 180 s breath-hold PET acquisitions. Materials and methods: This retrospective study included 10 adult patients with 13 liver masses who underwent FDG PET/CT-guided percutaneous biopsies (n = 5) or ablations (n = 5). PET was acquired as nine sequential 20 s, monitored, same-level breath-hold frames and CT was acquired in one monitored breath-hold. Twenty, 40, 60, and 180 s PET datasets were reconstructed. Two blinded readers marked tumour centres on randomized PET and CT datasets. Three-dimensional spatial localization differences between PET datasets and either 180 s PET or CT were analysed using multiple regression analyses. Statistical tests were two-sided and p < 0.05 was considered significant. Results: Targeting differences between 20 s PET and 180 s PET ranged from 0.7–20.3 mm (mean 5.3 ± 4.4 mm; median 4.3) and were not statistically different from 40 or 60 s PET (p = 0.74 and 0.91, respectively). Targeting differences between 20 s PET and CT ranged from 1.4–36 mm (mean 9.6 ± 7.1 mm; median 8.2 mm) and were not statistically different from 40, 60, or 180 s PET (p = 0.84, 0.77, and 0.35, respectively). Conclusion: Single 20 s breath-hold PET acquisitions from PET/CT-guided percutaneous liver procedures have the potential to target FDG-avid liver masses with equivalent accuracy to 180 s summed, breath-hold PET acquisitions and may facilitate strategies that improve image registration and shorten procedure times

  18. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com [University Hospital of Strasbourg, Department of Interventional Radiology (France); Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier, Jean, E-mail: caudjean@yahoo.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France); Rao, Pramod, E-mail: pramodrao@me.com [University of Strasbourg, ICube (France); Tsoumakidou, Georgia, E-mail: Georgia.tsoumakidou@chru-strasbourg.fr; Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Gangi, Afshin, E-mail: Afshin.gangi@chru-strasbourg.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France)

    2016-09-15

    ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  19. Percutaneous CT and Fluoroscopy-Guided Screw Fixation of Pathological Fractures in the Shoulder Girdle: Technical Report of 3 Cases

    International Nuclear Information System (INIS)

    Garnon, Julien; Koch, Guillaume; Ramamurthy, Nitin; Caudrelier, Jean; Rao, Pramod; Tsoumakidou, Georgia; Cazzato, Roberto Luigi; Gangi, Afshin

    2016-01-01

    ObjectiveTo review our initial experience with percutaneous CT and fluoroscopy-guided screw fixation of pathological shoulder-girdle fractures.Materials and MethodsBetween May 2014 and June 2015, three consecutive oncologic patients (mean age 65 years; range 57–75 years) with symptomatic pathological shoulder-girdle fractures unsuitable for surgery and radiotherapy underwent percutaneous image-guided screw fixation. Fractures occurred through metastases (n = 2) or a post-ablation cavity (n = 1). Mechanical properties of osteosynthesis were adjudged superior to stand-alone cementoplasty in each case. Cannulated screws were placed under combined CT and fluoroscopic guidance with complementary radiofrequency ablation or cementoplasty to optimise local palliation and secure screw fixation, respectively, in two cases. Follow-up was undertaken every few weeks until mortality or most recent appointment.ResultsFour pathological fractures were treated in three patients (2 acromion, 1 clavicular, 1 coracoid). Mean size of associated lesion was 2.6 cm (range 1–4.5 cm). Technical success was achieved in all cases (100 %), without complications. Good palliation and restoration of mobility were observed in two cases at 2–3 months; one case could not be followed due to early post-procedural oncologic mortality.ConclusionPercutaneous image-guided shoulder-girdle osteosynthesis appears technically feasible with good short-term efficacy in this complex patient subset. Further studies are warranted to confirm these promising initial results.

  20. Successful treatment of tumor-induced osteomalacia with CT-guided percutaneous ethanol and cryoablation.

    Science.gov (United States)

    Tutton, Sean; Olson, Erik; King, David; Shaker, Joseph L

    2012-10-01

    Tumor-induced osteomalacia is a rare condition usually caused by benign mesenchymal tumors. When the tumor can be found, patients are usually managed by wide excision of the tumor. We report a 51-yr-old male with clinical and biochemical evidence of tumor-induced osteomalacia caused by a mesenchymal tumor in the right iliac bone. He declined surgery and appears to have been successfully managed by computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. Our patient appears to have had an excellent clinical and biochemical response to computed tomography-guided percutaneous ethanol ablation and percutaneous cryoablation. We found one prior case of image-guided ablation using radiofrequency ablation for tumor-induced osteomalacia. Although the standard treatment for tumor-induced osteomalacia is wide excision of the tumor, image-guided ablation may be an option in patients who cannot have appropriate surgery or who decline surgery.

  1. CT-guided core-needle biopsy in omental pathology

    International Nuclear Information System (INIS)

    Pombo, F.; Rodriguez, E.; Martin, R.; Lago, M.

    1997-01-01

    Purpose: To assess the accuracy and clinical usefulness of CT-guided core-needle biopsy in the diagnosis of omental pathology. Material and Methods: We retrospectively reviewed the results of CT-guided percutaneous core biopsies in 25 patients with focal (n=2) or diffuse (n=23) omental pathology. These results were compared to the final diagnoses as determined by laparotomy (n=15), laparoscopic biopsy (n=3), endoscopic biopsy (n=1), or by the results of percutaneous biopsy and clinical-radiological and bacteriological modalities (n=6). The final diagnoses showed 4 patients with isolated omental pathology and 21 with widespread peritoneal involvement. The CT-guided biopsies were performed with 1.0=1.8-mm Surecut core-needles. Results: In 16 patients, the final diagnosis was metastatic adenocarcinoma - with the primary tumor sites in the ovary (n=3), stomach (n=1), appendix (n=2), and unknown (n=10). In the remaining 9 patients, the final diagnosis was hepatocellular carcinoma, lymphoma, and mesothelioma in 1 patient each; tuberculosis in 5; and actinomycosis in 1. Sufficient histological (n=16) or cytological (n=8) material was obtained by CT biopsy in 24/25 (96%) cases; the specimen was insufficient for diagnosis in 1 case. In differentiating benign from malignant disease, CT-guided biopsy showed a sensitivity, specificity and accuracy of respectively 89.5%, 100% and 92%. It gave a specific diagnosis in 78.9% (15/19) of patients with malignant conditions and in 50% (3/6) of patients with benign disorders. There were no biopsy-related complications. Conclusion: CT-guided percutaneous core-needle biopsy of the omentum is a safe, useful and highly accurate procedure for diagnosing malignant omental pathology. (orig.)

  2. Percutaneous catheter drainage of empyema and loculated pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Im, Jung Gi; Park, Kyung Joo; Park, Jae Hyung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1988-08-15

    Closed thoracotomy by using a chest tube in cases of thoracic empyema is known to be an effective and popular way of treatment. However, it happens commonly that chest tube drainage is not appropriate because of either malpositioning of the tube or undesirable patient's general condition such as bleeding tendency or debilitation. We performed fluoroscopy-guided percutaneous catheter drainage (PCD) in 14 cases of empyema and loculated pleural effusion and in 2 cases of lung abscess. In most of the patients, PCDs were performed because chest tube drainage was considered to be inappropriate or after failed chest tube drainage. In all patients, catheters were successfully placed into the fluid collections, which were drained effectively. Ten of the 11 febrile patient showed improvement of feverishness within 24 hours after PCD. 10 patients were cured without further treatment. Complications were few and minimal. We believe that the safety, effectiveness and good patients tolerance of PCD makes it an excellent alternative method of treatment in cases of empyema and loculated pleural effusion.

  3. Laparoscopy‑guided Liver Abscess Drainage: An Additional Use of ...

    African Journals Online (AJOL)

    treatment of liver abscess in Nigeria, to the best of our knowledge. CASE REpORT. A 34-year-old male commercial driver presented at the general surgery outpatient clinic of the Federal Medical. Centre Owerri with a 3-week history of abdominal swelling. AbSTrACT. Percutaneous image-guided drainage is the standard of.

  4. CT-guided percutaneous laser disk decompression for cervical and lumbar disk hernia

    International Nuclear Information System (INIS)

    Shimizu, Kanichiro; Koyama, Tutomu; Harada, Junta; Abe, Toshiaki

    2008-01-01

    Percutaneous laser disk decompression under X-ray fluoroscopy was first reported in 1987 for minimally invasive therapy of lumbar disk hernia. In patients with disk hernia, laser vaporizes a small portion of the intervertebral disk thereby reducing the volume and pressure of the affected disk. We present the efficacy and safety of this procedure, and analysis of fair or poor response cases. In our study, 226 cases of lumbar disk hernia and 7 cases of cervical disk hernia were treated under CT guided PLDD. Japan Orthopedic Association (JOA) score and Mac-Nab criteria were investigated to evaluate the response to treatment. Improvement ratio based on the JOA score was calculated as follows. Overall success rate was 91.6% in cases lumber disk hernia, and 100% in cases of cervical disk hernia. We experienced two cases with two cases with postoperative complication. Both cases were treated conservatively. The majority of acute cases and post operative cases were reported to be 'good' on Mac-Nab criteria. Cases of fair or poor response on Mac-Nab criteria were lateral type, foraminal stenosis or large disk hernia. CT-guided PLDD is a safe and accurate procedure. The overall success rate can be increased by carefully selecting patients. (author)

  5. Treatment of osteoid osteoma using CT-guided radiofrequency ablation versus MR-guided laser ablation: A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Gebauer, B.; Wieners, G.; De Bucourt, M.; Renz, D.M.; Hamm, B.; Streitparth, F.

    2012-01-01

    Objective: To compare the costs of CT-guided radiofrequency ablation (RFA) and MR-guided laser ablation (LA) for minimally invasive percutaneous treatment of osteoid osteoma. Materials and methods: Between November 2005 and October 2011, 20 patients (14 males, 6 females, mean age 20.3 ± 9.1 years) underwent CT-guided RFA and 24 patients (18 males, 6 females; mean age, 23.8 ± 13.8 years) MR-guided LA (open 1.0 Tesla, Panorama HFO, Philips, Best, Netherlands) for osteoid osteoma diagnosed on the basis of clinical presentation and imaging findings. Prorated costs of equipment use (purchase, depreciation, and maintenance), staff costs, and expenditure for disposables were identified for CT-guided RFA and MR-guided LA procedures. Results: The average total costs per patient were EUR 1762 for CT-guided RFA and EUR 1417 for MR-guided LA. These were (RFA/LA) EUR 92/260 for equipment use, EUR 149/208 for staff, and EUR 870/300 for disposables. Conclusion: MR-guided LA is less expensive than CT-guided RFA for minimally invasive percutaneous ablation of osteoid osteoma. The higher costs of RFA are primarily due to the higher price of the disposable RFA probes.

  6. Outcome of ultrasound-guided small-bore catheter drainage in exudative pleural effusions.

    Science.gov (United States)

    Kiranantawat, Nantaka; Sungsiri, Jitpreedee; Geater, Sarayut L

    2014-05-01

    To evaluate the outcome and safety of ultrasound-guided percutaneous catheter drainage of exudative pleural effusion. The present study was a retrospective analysis of 412 pleural effusions from 373 patients that underwent ultrasound-guided small-bore catheter drainage in exudative pleural effusions between 2004 and 2009. The two most common causes for drainage were parapneumonic effusion or empyema (52.2%) and malignant effusion (30.3%), while the remains were trauma, iatrogenic, and others. Overall clinical success rate was 76.5%. The success rate was lower among malignant pleural effusion (p = 0.003). Causes of effusion were the only independent predictors related to success. Only five (1.2%) patients developed complication during the procedure. Seventy-five of 412 effusions (15.8%) developed complication during the period of drainage; the majority were drain blockage (9%) and accidental dislodgment (4.1%). Ultrasound-guided small-bore catheter drainage was a safe and efficient procedure for exudative pleural effusions.

  7. Percutaneous transcatheter drainage of intrathoracic air and fluid collections

    International Nuclear Information System (INIS)

    Klein, J.S.; Salmon, C.J.

    1991-01-01

    In this paper, the authors review their experience with radiologically guided percutaneous, small-bore catheter drainage of 89 intrathoraic air or fluid collections in 81 patients to determine the effect of various clinical and radiographic features and fluid characteristics on successful treatment of the collections. The majority of patients underwent drainage for malignant pleural effusion. Patients with pneumothorax, complicated parapneumonic effusion or empyema, hemothorax, chylothorax, and lung abscess were included. Each patient's diagnosis and symptoms; the size, position, and characteristics of the fluid collection; catheter type and size, and use of urokinase were recorded; their effect on clinical and radiographic resolution was determined with logistic regression analysis. The vast majority of malignant effusions were successfully drained and sclerosed with small bore (8-F) pigtail catheters. In patients with pneumothorax, those from Pneumocystis carinii pneumonia required prolonged suction and pleurodesis

  8. Treatment of lung abscess: effectiveness of percutaneous catheter drainage in 14 patients

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Su Hyun; Han, Young Min; Kim, Chong Soo; Chung, Gyung Ho; Ryu, Chun Su; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University Medical School, Cheonju (Korea, Republic of)

    1995-01-15

    To evaluate the effectiveness of percutaneous catheter drainage in treatment of the lung abscess. We treated the lung abscesses in 14 patients (12 mean, 2 women), who did not respond to medical therapy, by percutaneous catheter drainage under fluoroscopic or ultrasound guidance. One abscess due to infacted bulla was managed by combination treatment with alcohol sclerosing therapy. Patients were followed by serial chest radiographs every three days and the amount of drained or aspirated pus evaluated. The treatment effect and recurrence were followed by chest PA and lateral chest at one week after removal of drainage catheter. Thirteen patients (93%) recovered clinically and radiologically within 3 days. In 10 patients, drainage catheter could be removed within 2 weeks, and three patients, the catheter was kept longer. Most complications were mild; vague to moderate chest pain (n = 14), mild hemoptysis (n = 2), and pneumothorax (n = 1). One man who suffered from far advanced pulmonary tuberculosis died of asphyxia caused by massive hemoptysis 16 days after percutaneous drainage. Percutaneous catheter drainage is a safe and effective method for treating lung abscess.

  9. Percutaneous biliary drainage in acute suppurative cholangitis with biliary sepsis

    International Nuclear Information System (INIS)

    Kim, Hyung Lyul; Cho, June Sik; Kwon, Soon Tae; Lee, Sang Jin; Rhee, Byung Chull

    1993-01-01

    Acute suppurative cholangitis is a severe inflammatory process of the bile duct occurred as result of partial or complete obstruction of the bile duct, and may manifest clinically severe form of disease, rapidly deteriorating to life-threatening condition. We analyzed emergency percutaneous transhepatic biliary drainage in 20 patients of acute suppurative cholangitis with biliary sepsis to evaluate the therapeutic effect and complication of the procedure. The underlying cause were 12 benign disease(stones) and eight malignant tumors and among eight malignant tumors, bile duct stones(n=4) and clonorchiasis(n=1) were combined. Percutaneous transhepatic biliary drainage was performed successfully in 17 of 20 patients resulting in improvement of general condition and failed in three patients. The procedure were preterminated due to the patient's condition in two and biliary-proto fistula was developed in one. After biliary decompression by percutaneous transhepatic biliary drainage, effective and successful elective surgery was performed in nine cases, which were seven biliary stones and two biliary cancer with stones. Our experience suggest that emergency percutaneous transhepatic biliary drainage is an initial and effective treatment of choice for acute suppurative cholangitis with sepsis and a safe alternative for nonsurgical treatment

  10. Percutaneous necrosectomy in patients with acute, necrotizing pancreatitis

    Energy Technology Data Exchange (ETDEWEB)

    Bruennler, T.; Langgartner, J.; Lang, S.; Salzberger, B.; Schoelmerich, J. [University Hospital of Regensburg, Department of Internal Medicine 1, Regensburg (Germany); Zorger, N.; Herold, T.; Feuerbach, S.; Hamer, O.W. [University Hospital of Regensburg, Department of Radiology, Regensburg (Germany)

    2008-08-15

    The objective of this retrospective study was to evaluate the outcome of patients with acute necrotizing pancreatitis treated by active percutaneous necrosectomy. By searching the radiological, surgical and internal medicine databases, all patients with acute necrotizing pancreatitis treated by active percutaneous necrosectomy between 1992 and 2004 were identified. Demographic, laboratory, and clinical data, and details about invasive procedures were collected by reviewing patient charts, radiological and surgical reports. The computed tomography severity index (CTSI) scores were determined by reviewing CT images. Eighteen patients were identified. Median Ranson score on admission was 2. The Acute Physiology and Chronic Health Evaluation (APACHE) II score was median 22. Median CTSI score was 7. Initially all patients were treated with CT-guided drainage placement. Because passive drainage proved not to be effective, subsequent minimally invasive, percutaneous necrosectomy was performed. Eight out of 18 patients recovered fully without the need for surgery. Ten of 18 patients required additional surgical necrosectomy. For one of ten patients, percutaneous necrosectomy allowed postponing surgery by 39 days. Four of ten surgically treated patients died: three from septic multiorgan failure, one from pulmonary embolism. Percutaneous minimally invasive necrosectomy can be regarded as a safe and effective complementary treatment modality in patients with necrotizing pancreatitis. It is suitable for a subset of patients to avoid or delay surgery. (orig.)

  11. Percutaneous necrosectomy in patients with acute, necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Bruennler, T.; Langgartner, J.; Lang, S.; Salzberger, B.; Schoelmerich, J.; Zorger, N.; Herold, T.; Feuerbach, S.; Hamer, O.W.

    2008-01-01

    The objective of this retrospective study was to evaluate the outcome of patients with acute necrotizing pancreatitis treated by active percutaneous necrosectomy. By searching the radiological, surgical and internal medicine databases, all patients with acute necrotizing pancreatitis treated by active percutaneous necrosectomy between 1992 and 2004 were identified. Demographic, laboratory, and clinical data, and details about invasive procedures were collected by reviewing patient charts, radiological and surgical reports. The computed tomography severity index (CTSI) scores were determined by reviewing CT images. Eighteen patients were identified. Median Ranson score on admission was 2. The Acute Physiology and Chronic Health Evaluation (APACHE) II score was median 22. Median CTSI score was 7. Initially all patients were treated with CT-guided drainage placement. Because passive drainage proved not to be effective, subsequent minimally invasive, percutaneous necrosectomy was performed. Eight out of 18 patients recovered fully without the need for surgery. Ten of 18 patients required additional surgical necrosectomy. For one of ten patients, percutaneous necrosectomy allowed postponing surgery by 39 days. Four of ten surgically treated patients died: three from septic multiorgan failure, one from pulmonary embolism. Percutaneous minimally invasive necrosectomy can be regarded as a safe and effective complementary treatment modality in patients with necrotizing pancreatitis. It is suitable for a subset of patients to avoid or delay surgery. (orig.)

  12. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  13. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Cha, Soon Joo

    2002-01-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 ±3.8 min. in the right approach and 9.6 ±3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9±2.4 min. in the right approach and 3.8±2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD

  14. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Cha, Soon Joo [College of Medicine, Inje Univ., Kimhae (Korea, Republic of)

    2002-02-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 {+-}3.8 min. in the right approach and 9.6 {+-}3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9{+-}2.4 min. in the right approach and 3.8{+-}2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD.

  15. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor.

    Science.gov (United States)

    Panizza, Pedro Sergio Brito; de Albuquerque Cavalcanti, Conrado Furtado; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; de Menezes, Marcos Roberto

    2016-02-01

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  16. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    International Nuclear Information System (INIS)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; Menezes, Marcos Roberto de

    2016-01-01

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones

  17. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil); Yamaguchi, Nise Hitomi [Instituto Avanços em Medicina (Brazil); Leite, Claudia Costa; Cerri, Giovanni Guido; Menezes, Marcos Roberto de, E-mail: marcos.menezes@hc.fm.usp.br [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil)

    2016-02-15

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  18. Clinical application of percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation under CT guidance

    International Nuclear Information System (INIS)

    Wang Linyou; Li Yuan; Shao Yangtong

    2004-01-01

    Objective: To evaluate the effect of the percutaneous lumbar puncture to treat sciatica caused by lumbar disc herniation. Methods: 75 cases of lumbar disc herniation with significant clinical signs were confirmed by CT scan. The technique of the percutaneous lumbar puncture led the needle to approach nerve root and injected medicine diffusing into extraduramater, and then relieved the symptom of sciatica. Results: The rate of success of percutaneous lumbar puncture guided by CT reached to 100%. After two weeks of follow-up, the symptom of pain was obviously improved and disappeared in 63.3% cases. There were 23.0% cases needed a second procedure, and no change was obsesved in 9.3% cases. Conclusions: The percutaneous lumbar puncture guided by CT to treat sciatica resulted from lumbar disc herniation is one of the safe, reliable, effective new methods with no complication. The long term effectiveness is still in need of investigation. (authors)

  19. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    International Nuclear Information System (INIS)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens

    2014-01-01

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  20. Computed tomography-guided percutaneous biopsy of bone lesions: rate of diagnostic success and complications

    Energy Technology Data Exchange (ETDEWEB)

    Maciel, Macello Jose Sampaio; Tyng, Chiang Jeng; Barbosa, Paula Nicole Vieira Pinto; Bitencourt, Almir Galvao Vieira; Matushita Junior, Joao Paulo Kawaoka; Zurstrassen, Charles Edouard; Chung, Wu Tu; Chojniak, Rubens, E-mail: macellomaciel@me.com [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-09-15

    Objective: To determine the rates of diagnostic success and complications of computed tomography (CT)-guided percutaneous biopsy of bone lesions suspected for malignancy. Materials and Methods: Retrospective study including 186 cases of CT-guided percutaneous biopsies of bone lesions in the period from January, 2010 to December, 2012. All the specimens were obtained with 8-10 gauge needles. The following data were collected: demographics, previous history of malignancy, data related to the lesion, to the procedure, and to histological results. Results: Most patients were women (57%), and the mean age was 53.0 ± 16.4 years. In 139 cases (74.6%), there was diagnostic suspicion of metastasis and the most common primary tumors were breast (32.1%) and prostate (11.8%). The bones most commonly involved were spine (36.0%), hip (32.8%) and long bones (18.3%). Complications occurred in only three cases (1.6%) including bone fracture, paraesthesia with functional impairment, and needle breakage requiring surgical removal. The specimens collected from 183 lesions (98.4%) were considered appropriate for diagnosis. Malignant results were more frequently found in patients who had a suspected secondary lesion and history of known malignancy (p < 0.001), and in patients who underwent PET/CT-guided procedures (p = 0.011). Conclusion: CT-guided percutaneous biopsy is a safe and effective procedure for the diagnosis of suspicious bone lesions. (author)

  1. Treatment of infected bulla with alcohol sclerosis combined with percutaneous catheter drainage: a preliminary report

    International Nuclear Information System (INIS)

    Han, Young Min; Lee, Jeong Min; Kim, Chong Soo; Chung, Gyung Ho; Rhee, Yang Keen; Lee, Yong Chul; Sohn, Myung Hee; Choi, Ki Chul

    1995-01-01

    To evaluate effectiveness of alcohol sclerosis combined with percutaneous catheter drainage (PCD) for treatment of infected bulla. Infected bulla in four consecutive patients were treated. In all patients, percutaneous catheter drainage of the bulla was performed. Instillation of sterile alcohol (99% ethanol) was carried out into the cavity of the bulla. Alcohol was left in the cavity for approximately 30 minutes in each session. Alcohol instillation was repeated according to the size of bulla. Patients were subsequently followed up with serial chest radiographs and CT scans. All patients showed significant improvement both clinically and radiologically. Disappearance of the bulla and reexpansion of surrounding lung parenchyma was observed in two patients and partial resolution (80% reduction in size) was seen in another two patients. Complications included mild chest pain during instillation of alcohol in all patients and delayed radiating shoulder pain in one patient. We provisionally conclude that intracavitary alcohol instillation combined with PCD is effective in the treatment of the infected bulla

  2. Percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis

    International Nuclear Information System (INIS)

    Jung, Jin Yong; Jeong, Yong Yeon; Kim, Jae Kyu; Park, Seung Jei; Park, Jin Gyoon; Kang, Heoung Keun; Roh, Byung Suk

    1997-01-01

    To assess the usefulness of percutaneous drainage of abscess in the treatment of emphysematous pyelonephritis. Ten cases of nine patients with emphysematous pyelonephritis were percutaneously drained. All were suffering from diabetes mellitus. The procedure was performed under fluoroscopic guidance in nine cases and US guidance in one case in which bilateral multiloculated abscesses were present in the perirenal space. The results were classified as cure, partial success, recurrence, or failure. The mean drainage period and complication were analyzed. Eight cases were cured, and there was one case success. In one case, who had diffuse renal parenchymal destruction without perirenal fluid collection, the treatment failed. The longest drainage period was 45 days, in a case of re-insertion due to incidental catheter removal; the mean was 23 days. Bacteremia in one case was cured with antibiotic therapy which lasted two days. In diabetic patients, percutaneous drainage of obscess is thought to be a safe and effective method for the treatment of emphysematous pyelonephritis, and is one that does not involve diffuse destruction of renal parenchyma

  3. Infectious peritonitis after endoscopic ultrasound-guided biliary drainage in a patient with ascites

    Directory of Open Access Journals (Sweden)

    Nozomi Okuno

    2018-04-01

    Full Text Available Summary of Event: Bacterial, mycotic peritonitis and Candida fungemia developed in a patient with moderate ascites who had undergone endoscopic ultrasound-guided biliary drainage (EUS-BD. Antibiotics and antifungal agent were administered and ascites drainage was performed. Although the infection improved, the patient’s general condition gradually deteriorated due to aggravation of the primary cancer and he died.Teaching Point: This is the first report to describe infectious peritonitis after EUS-BD. Ascites carries the potential risk of severe complications. As such, in patients with ascites, endoscopic retrograde cholangiopancreatography (ERCP is typically preferred over EUS-BD or percutaneous drainage to prevent bile leakage. However, ERCP may not be possible in some patients with tumor invasion of the duodenum or with surgically altered anatomy. Thus, in patients with ascites who require EUS-BD, we recommend inserting the drainage tube percutaneously and draining the ascites before and after the intervention in order to prevent severe infection.

  4. Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

    International Nuclear Information System (INIS)

    Sarma, Asha; Shyn, Paul B.; Vivian, Mark A.; Ng, Ju-Mei; Tuncali, Kemal; Lorch, Jorchen H.; Zaheer, Sarah N.; Gordon, Michael S.; Silverman, Stuart G.

    2015-01-01

    Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements

  5. Single-Session CT-Guided Percutaneous Microwave Ablation of Bilateral Adrenal Gland Hyperplasia Due to Ectopic ACTH Syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Sarma, Asha, E-mail: ashasarma@gmail.com; Shyn, Paul B., E-mail: pshyn@partners.org [Brigham and Women’s Hospital, Department of Radiology (United States); Vivian, Mark A. [University of Manitoba, Department of Radiology (Canada); Ng, Ju-Mei [Brigham and Women’s Hospital, Department of Anesthesiology (United States); Tuncali, Kemal [Brigham and Women’s Hospital, Department of Radiology (United States); Lorch, Jorchen H. [Dana Farber Cancer Institute, Department of Medicine (United States); Zaheer, Sarah N.; Gordon, Michael S. [Brigham and Women’s Hospital, Department of Endocrinology (United States); Silverman, Stuart G. [Brigham and Women’s Hospital, Department of Radiology (United States)

    2015-10-15

    Bilateral adrenalectomy is currently the only available treatment for adrenocorticotropic hormone (ACTH)-dependent Cushing’s syndrome (ectopic ACTH syndrome) that is refractory to pharmacologic therapy. We describe two patients with refractory ectopic ACTH syndrome who were treated with CT-guided percutaneous microwave ablation of both hyperplastic adrenal glands in a single session: One was not a surgical candidate, and the other had undergone unsuccessful surgery. Following the procedure, both patients achieved substantial decreases in serum cortisol, symptomatic improvement, and decreased anti-hypertensive medication requirements.

  6. Preoperative endoscopic versus percutaneous transhepatic biliary drainage in potentially resectable perihilar cholangiocarcinoma (DRAINAGE trial): design and rationale of a randomized controlled trial.

    Science.gov (United States)

    Wiggers, Jimme K; Coelen, Robert J S; Rauws, Erik A J; van Delden, Otto M; van Eijck, Casper H J; de Jonge, Jeroen; Porte, Robert J; Buis, Carlijn I; Dejong, Cornelis H C; Molenaar, I Quintus; Besselink, Marc G H; Busch, Olivier R C; Dijkgraaf, Marcel G W; van Gulik, Thomas M

    2015-02-14

    Liver surgery in perihilar cholangiocarcinoma (PHC) is associated with high postoperative morbidity because the tumor typically causes biliary obstruction. Preoperative biliary drainage is used to create a safer environment prior to liver surgery, but biliary drainage may be harmful when severe drainage-related complications deteriorate the patients' condition or increase the risk of postoperative morbidity. Biliary drainage can cause cholangitis/cholecystitis, pancreatitis, hemorrhage, portal vein thrombosis, bowel wall perforation, or dehydration. Two methods of preoperative biliary drainage are mostly applied: endoscopic biliary drainage, which is currently used in most regional centers before referring patients for surgical treatment, and percutaneous transhepatic biliary drainage. Both methods are associated with severe drainage-related complications, but two small retrospective series found a lower incidence in the number of preoperative complications after percutaneous drainage compared to endoscopic drainage (18-25% versus 38-60%, respectively). The present study randomizes patients with potentially resectable PHC and biliary obstruction between preoperative endoscopic or percutaneous transhepatic biliary drainage. The study is a multi-center trial with an "all-comers" design, randomizing patients between endoscopic or percutaneous transhepatic biliary drainage. All patients selected to potentially undergo a major liver resection for presumed PHC are eligible for inclusion in the study provided that the biliary system in the future liver remnant is obstructed (even if they underwent previous inadequate endoscopic drainage). Primary outcome measure is the total number of severe preoperative complications between randomization and exploratory laparotomy. The study is designed to detect superiority of percutaneous drainage: a provisional sample size of 106 patients is required to detect a relative decrease of 50% in the number of severe preoperative

  7. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  8. The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Shirono, Ryozo; Takechi, Katsuya [Tokushima Red Cross Hospital, Department of Radiology (Japan); Yonekura, Hironobu [Tokushima Red Cross Hospital, Department of Radiological Technology (Japan); Iwamoto, Seiji [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan); Shinya, Takayoshi [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Takao, Shoichiro [Tokushima University Graduate School of Health Science, Department of Diagnostic Radiology (Japan); Harada, Masafumi [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan)

    2017-06-15

    Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

  9. Percutaneous CT-guided cryoablation of the dorsal penile nerve for treatment of symptomatic premature ejaculation.

    Science.gov (United States)

    David Prologo, J; Snyder, Laura L; Cherullo, Edward; Passalacqua, Matthew; Pirasteh, Ali; Corn, David

    2013-02-01

    To evaluate expansion of image-guided interventional cryoablation techniques usually employed for pain management to address the feasibility, safety, and efficacy of treatment for a urologic condition with otherwise limited treatment options, premature ejaculation (PE). Prospective institutional review board approval was obtained, and 24 subjects with PE were enrolled. All patients underwent unilateral percutaneous computed tomography-guided cryoablation of the dorsal penile nerve (DPN). Postprocedural intravaginal ejaculatory latency times (IELTs) and PE Profile (PEP) results served as outcome variables. In addition, subjects were asked whether they would have the procedure done again based on their experience at the 180- and 360-day marks. The technical success rate was 100%. Baseline average IELT was 54.7 seconds ± 7.8 (n = 24), which increased to a maximum of 256 seconds ± 104 (n = 11; P = .241) by day 7 and decreased to 182.5 seconds ± 87.8 (n = 6; P = .0342) by day 90. The mean IELT remained at 182.5 seconds ± 27.6 at day 180 (n = 23; PIELTs significantly improved at 180 and 360 days, and 83% of subjects reported that they would undergo the procedure again if given the same opportunity. There were no procedure-related complications. CT-guided percutaneous unilateral cryoablation of the DPN is a feasible, safe, single-day outpatient procedure for the treatment of symptomatic PE. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  10. CT-Guided Percutaneous Step-by-Step Radiofrequency Ablation for the Treatment of Carcinoma in the Caudate Lobe

    Science.gov (United States)

    Dong, Jun; Li, Wang; Zeng, Qi; Li, Sheng; Gong, Xiao; Shen, Lujun; Mao, Siyue; Dong, Annan; Wu, Peihong

    2015-01-01

    Abstract The location of the caudate lobe and its complex anatomy make caudate lobectomy and radiofrequency ablation (RFA) under ultrasound guidance technically challenging. The objective of the exploratory study was to introduce a novel modality of treatment of lesions in caudate lobe and discuss all details with our experiences to make this novel treatment modality repeatable and educational. The study enrolled 39 patients with liver caudate lobe tumor first diagnosed by computerized tomography (CT) or magnetic resonance imaging (MRI). After consultation of multi-disciplinary team, 7 patients with hepatic caudate lobe lesions were enrolled and accepted CT-guided percutaneous step-by-step RFA treatment. A total of 8 caudate lobe lesions of the 7 patients were treated by RFA in 6 cases and RFA combined with percutaneous ethanol injection (PEI) in 1 case. Median tumor diameter was 29 mm (range, 18–69 mm). A right approach was selected for 6 patients and a dorsal approach for 1 patient. Median operative time was 64 min (range, 59–102 min). Median blood loss was 10 mL (range, 8-16 mL) and mainly due to puncture injury. Median hospitalization time was 4 days (range, 2–5 days). All lesions were completely ablated (8/8; 100%) and no recurrence at the site of previous RFA was observed during median 8 months follow-up (range 3–11 months). No major or life-threatening complications or deaths occurred. In conclusion, percutaneous step-by-step RFA under CT guidance is a novel and effective minimally invasive therapy for hepatic caudate lobe lesions with well repeatability. PMID:26426638

  11. CT-guided percutaneous neurolysis methods. State of the art and first results

    International Nuclear Information System (INIS)

    Schneider, B.; Richter, G.M.; Roeren, T.; Kauffmann, G.W.

    1996-01-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [de

  12. Percutaneous drainage of a postoperative intraspinal hematoma using a Tuohy needle

    Energy Technology Data Exchange (ETDEWEB)

    Teo, Harvey E.L. [Department of Diagnostic Radiology, KK Women' s and Children' s Hospital (Singapore); Peh, Wilfred C.G. [Department of Diagnostic Radiology, KK Women' s and Children' s Hospital (Singapore); Programme Office, Singapore Health Services, 7 Hospital Drive 02-09, 169611 (Singapore); Tan, Seang Beng [Department of Orthopaedic Surgery, Singapore General Hospital (Singapore)

    2003-10-01

    A 78-year-old man developed a large subdural hematoma extending from T12 to L3 levels following L3 laminectomy and L3-5 posterior spinal fusion. He had associated neurological signs and symptoms. MR imaging showed typical signal characteristics of a subacute intraspinal subdural hematoma. Percutaneous drainage was successfully performed under CT guidance by inserting a Tuohy needle through the L3 laminectomy defect. The catheter packaged with the Tuohy needle was inserted cranially into the hematoma and 30 ml of blood was aspirated. Follow-up MR imaging confirmed resolution of the hematoma and the patient made a rapid recovery. (orig.)

  13. CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes for the treatment of intractable carcinomatous abdominal pain

    International Nuclear Information System (INIS)

    Xi Qian; Wang Peijun; Shang Mingyi; Ma Jun; Lu Ying; Huang Zongliang; Tang Junjun; Gao Xiaolong

    2010-01-01

    Objective: To evaluate CT-guided percutaneous ethanol nerve block therapy of celiac plexus embedded in metastatic lymph nodes in treating intractable carcinomatous abdominal pain. Methods: A total of 104 patients with late stage cancers were enrolled in this study. All patients suffered from serious carcinomatous pain at upper abdomen and their retroperitoneal lymph nodes were extensively enlarged and fused, together with the involved celiac plexus, into a hard crumb. As the patients failed to respond to narcotic analgesics CT-guided ethanol nerve block therapy of celiac plexus was carried out by pushing the puncture needle through the fused lymphatic mass to celiac plexus site. The analgesic effects and complications were observed and the therapeutic results were evaluated. Results: The analgesic effective rate of ethanol nerve block therapy immediately after the procedure was 100%, and at 2 weeks, 1, 2, 3 and 4 months after the treatment it was 100%, 100%, 98.0%, 96.9% and 92.6%, respectively. No serious complications occurred during perioperative period. The living quality was markedly improved in all patients. Conclusion: For the treatment of intractable carcinomatous abdominal pain in patients with their celiac plexus being embedded in mass-like metastatic retroperitoneal lymph nodes CT-guided percutaneous ethanol nerve block therapy by pushing the puncture needle through the fused lymphatic mass to celiac plexus site is of great clinical value in relieving carcinomatous abdominal pain. (authors)

  14. Peritoneal seeding of cholangiocarcinoma in patients with percutaneous biliary drainage

    International Nuclear Information System (INIS)

    Miller, G.A. Jr.; Heaston, D.K.; Moore, A.V. Jr.; Mills, S.R.; Dunnick, N.R.

    1983-01-01

    Percutaneous transhepatic catheter decompression is performed increasingly as an adjunct or alternative to surgery in patients with benign or malignant biliary obstruction. The authors recently saw three patients with cholangiocarcinoma in whom metastatic seeding of the peritoneal serosa was identified some months after initial percutaneous transhepatic biliary drainage. Although no tumor was found along the hepatic tract of the biliary drainage catheters to implicate the drainage tubes as the direct source of peritoneal spread, the occurrence of this rare type of metastasis of cholangiocarcinoma in patients with potential access of tumor cells to the peritoneal cavity via the catheter tracts does suggest such a relation. The clinical history of one patient is presented

  15. Lung abscess; Percutaneous catheter therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ha, H.K. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Kang, M.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Park, J.M. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Yang, W.J. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Shinn, K.S. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of)); Bahk, Y.W. (Depts. of Radiology and Internal Medicine, Catholic Univ. Medical Coll., Seoul (Korea, Republic of))

    1993-07-01

    Lung abscess was successfully treated with percutaneous drainage in 5 of 6 patients. Complete abscess resolution occurred in 4 patients, partial resolution in one, and no response in one. The duration of drainage ranged from 7 to 18 days (mean 15.5 days) in successful cases. The failure of drainage in one neurologicall impaired patient was attributed to persistent aspiration. In 2 patients, concurrent pleural empyema was also cured. CT provided the anatomic details necessary for choosing the puncture site and avoiding puncture of the lung parenchyma. Percutaneous catheter drainage is a safe and effective method for treating lung abscess. (orig.).

  16. Role of percutaneous abscess drainage in the management of young patients with Crohn disease

    Energy Technology Data Exchange (ETDEWEB)

    Pugmire, Brian S. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Gee, Michael S. [Massachusetts General Hospital for Children, Department of Radiology, Boston, MA (United States); Massachusetts General Hospital, Division of Abdominal Imaging, Boston, MA (United States); Kaplan, Jess L.; Winter, Harland S. [Massachusetts General Hospital for Children, Department of Pediatrics, Boston, MA (United States); Hahn, Peter F.; Gervais, Debra A. [Massachusetts General Hospital, Division of Abdominal Imaging, Boston, MA (United States); Doody, Daniel P. [Massachusetts General Hospital for Children, Department of Surgery, Boston, MA (United States)

    2016-05-15

    Intra-abdominal abscess is a common complication of Crohn disease in children. Prior studies, primarily in adults, have shown that percutaneous abscess drainage is a safe and effective treatment for this condition; however, the data regarding this procedure and indications in pediatric patients is limited. Our aim was to determine the success rate of percutaneous abscess drainage for abscesses related to Crohn disease in pediatric patients with a focus on treatment endpoints that are relevant in the era of biological medical therapy. We retrospectively reviewed 25 cases of patients ages ≤20 years with Crohn disease who underwent percutaneous abscess drainage. Technical success was defined as catheter placement within the abscess with reduction in abscess size on post-treatment imaging. Clinical success was defined as (1) no surgery within 1 year of drainage or (2) surgical resection following drainage with no residual abscess at surgery or on preoperative imaging. Multiple clinical parameters were analyzed for association with treatment success or failure. All cases were classified as technical successes. Nineteen cases were classified as clinical successes (76%), including 7 patients (28%) who required no surgery within 1 year of percutaneous drainage and 12 patients (48%) who had elective bowel resection within 1 year. There was a statistically significant association between resumption of immunosuppressive therapy within 8 weeks of drainage and both clinical success (P < 0.01) and avoidance of surgery after 1 year (P < 0.01). Percutaneous abscess drainage is an effective treatment for Crohn disease-related abscesses in pediatric patients. Early resumption of immunosuppressive therapy is statistically associated with both clinical success and avoidance of bowel resection, suggesting a role for percutaneous drainage in facilitating prompt initiation of medical therapy and preventing surgical bowel resection. (orig.)

  17. Cholescintigraphy in patients with acute cholecystitis before and after percutaneous gallbladder drainage

    DEFF Research Database (Denmark)

    Borly, L; Stage, J G; Grønvall, S

    1995-01-01

    gallbladder drainage. During the post-drainage cholescintigraphies, a cholecystokinin stimulation was performed to investigate gallbladder emptying in 12 selected patients. Gallbladder pressure and volume were measured before drainage in another group of 12 patients with acute cholecystitis. RESULTS......OBJECTIVE: To investigate gallbladder function by use of cholescintigraphy in patients with acute cholecystitis before and after percutaneous gallbladder drainage. DESIGN: A cholescintigraphy was performed in 40 patients with acute cholecystitis before and after the performance of percutaneous......: As expected, no gallbladder activity was observed in the cholescintigraphies before drainage, except in a patient with an occluding stone in the common bile duct. Cystic duct patency and gallbladder activity were seen in 80% of patients in cholescintigraphies performed after drainage but before any other...

  18. Osteoid osteoma: percutaneous treatment with CT guidance

    International Nuclear Information System (INIS)

    Velan, Osvaldo; Ayzaguer, Alejandro H.; Endara Bustos, Olinda; Lambertini, Roberto G.

    2004-01-01

    Purpose: The osteoid osteoma (OO) is a benign bone tumor characterized by causing severe and constant pain at night, and for that reason it requires a surgical excision. Although for years the treatment of choice has been surgery, the development of CT-guided percutaneous procedures, such as percutaneous resection with trephine (PR), and more recently the radiofrequency ablation (RF), it is possible to remove the core of the lesion and therefore relieve the symptoms in a considerably less invasive way. Material and methods: Between January 1990 and February 2004, 65 lesions in 60 patients with a presumptive diagnosis of osteoid osteoma were treated. 49 PRs and 16 RFs were performed. Of the 49 PRs, 5 required curettage and one required an ethanol injection. The procedures were guided by CT imaging under general or spinal anesthesia with 24 hr hospitalization. Tumor samples were taken for anatomical pathology analysis (AP). The absence of symptoms and late complications was verified 30 days after the procedure. Results: All lesions were accessed successfully. In 5 of them it was necessary to broaden the resection due to a possible insufficient margin. In 38 of the 65 lesions (58,5%) AP confirmed the OO diagnosis; in 6/65 (9.2%) of them AP found other specific lesions, such as enostoma (n=2), bone cyst (n=1), inclusion cyst (n=1), chondroma (n=1), and chronic osteitis (n=1), and in the rest of the cases the findings were unspecified. All patients (60/60) showed no pain within 24-48 hours of the procedure, and 5/60 (8,3%) received further treatment due to recurring symptoms. Conclusion: The percutaneous procedure has shown to be an effective technique for the treatment of OO. Compared to surgical excision, the percutaneous technique is less invasive, it requires less anesthesia and hospitalization time, and it allows an earlier return to active life. The PR is less expensive than the RF, but it requires a wider bone incision. However, both techniques are equally

  19. CT-guided conformal cryoablation for peripheral NSCLC: Initial experience

    International Nuclear Information System (INIS)

    Zhang, Xiao; Tian, Jinlin; Zhao, Lei; Wu, Bin; Kacher, Daniel S.; Ma, Xuyang; Liu, Shurong; Ren, Chao; Xiao, Yue-Yong

    2012-01-01

    Purpose: To study the feasibility of CT-guided and monitored percutaneous conformal cryoablation of Non-Small Cell Lung Cancer for patients who are not suitable for surgical resection. Materials and method: CT-guided percutaneous conformal cryoablation was performed on 46 patients with peripheral Non-Small Cell Lung Cancer. Patients with tumor sizes less than 3 cm in diameter were treated with double-needle clamping cryoablation, while the patients with 3–5 cm tumor sizes were treated with multiple-needle conformal cryoablation. CT was used to monitor the extent of cryoablation during the procedures. At month 1, 3, 6, 12, and 24 post-procedure, enhanced CT scans and/or PET-CT scans were performed to evaluate the impact of the therapy. Results: The average tumor CT values were 32 ± 10 HU and −21 ± 8 HU before and after cryoablation, respectively. The largest diameters of the lesions at month 1, 3, 6, 12, and 24 post-procedure were 2.63 ± 0.56 cm, 1.93 ± 0.51 cm, 1.55 ± 0.39 cm, 1.43 ± 0.40 cm, and 1.38 ± 0.38 cm, respectively, in patients with tumor diameter less than 3 cm, and 3.63 ± 0.39 cm, 2.98 ± 0.31 cm, 2.62 ± 0.32 cm, 2.54 ± 0.34 cm, and 2.56 ± 0.37 cm respectively in patients with the tumor diameters between 3 and 5 cm. At the 24th month, there were 36 cases of complete response (83.7%), 7 cases of partial response (16.3%), and no cases of stable disease or progressive disease. 3 patients died due to multiple metastases. Conclusion: CT-guided percutaneous conformal cryoablation is a safe, effective, and minimally invasive therapeutic method for peripheral lung cancer.

  20. CT-guided injection of botulinic toxin for percutaneous therapy of piriformis muscle syndrome with preliminary MRI results about denervative process

    Energy Technology Data Exchange (ETDEWEB)

    Fanucci, E.; Masala, S.; Sodani, G.; Varrucciu, V.; Romagnoli, A.; Squillaci, E.; Simonetti, G. [Dept. of Radiology, Univ. of Rome (Italy)

    2001-12-01

    Piriformis muscle syndrome (PMS) is a cause of sciatica, leg or buttock pain and disability. The pain is usually increased by muscular contraction, palpation or prolonged sitting. The aim of our paper was to evaluate the feasibility of CT-guided percutaneous botulinic toxin (BTX) injection for the purpose of PMS treatment. Thirty patients suffering from PMS, suspected with clinical and electrophysiological criteria, after imaging examinations excluding other causes of sciatic pain, resulted positive at the lidocaine test and were treated by intramuscular injection of BTX type A under CT guidance. The follow-up (12 months) was performed with clinical examination in all cases and with MR 3 months after the procedure in 9 patients to evaluate the denervative process entity of the treated muscle. In 26 cases relief of symptoms was obtained after 5-7 days. In 4 patients an insufficient relief of pain justified a second percutaneous treatment which was clinically successful. No complications or side effects were recorded after BTX injection. The MR examination showed a signal intensity change of the treated muscle in 7 patients due to the denervative process of PM, whereas in the remaining 2 cases only an atrophy of the treated muscle was detected. Larger series are necessary to confirm these MRI preliminary results. The CT-guided BTX injection in the PMS is an emergent and feasible technique that obtains an excellent local therapeutic effect without risk of imprecise inoculation. (orig.)

  1. Use of cone-beam CT and live 3-D needle guidance to facilitate percutaneous nephrostomy and nephrolithotripsy access in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C.M. [Emory University School of Medicine, Department of Radiology and Imaging Sciences, Atlanta, GA (United States); Kukreja, Kamlesh [Texas Children' s Hospital, Department of Radiology, Houston, TX (United States); Singewald, Timothy; Johnson, Neil D.; Racadio, John M. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Minevich, Eugene; Reddy, Pramod [Cincinnati Children' s Hospital Medical Center, Department of Urology, Cincinnati, OH (United States)

    2016-04-15

    Gaining access into non-dilated renal collecting systems for percutaneous nephrolithotripsy, particularly in patients with prohibitive body habitus and/or scoliosis, is often challenging using conventional techniques. To evaluate the feasibility of cone-beam CT for percutaneous nephrostomy placement for subsequent percutaneous nephrolithotripsy in children and adolescents. A retrospective review of percutaneous nephrostomy revealed use of cone-beam CT and 3-D guidance in 12 percutaneous nephrostomy procedures for 9 patients between 2006 and 2015. All cone-beam CT-guided percutaneous nephrostomies were for pre-lithotripsy access and all 12 were placed in non-dilated collecting systems. Technical success was 100%. There were no complications. Cone-beam CT with 3-D guidance is a technically feasible technique for percutaneous nephrostomy in children and adolescents, specifically for nephrolithotripsy access in non-dilated collecting systems. (orig.)

  2. CT guided puncture aspiration and sclerosing treatment of ovary cyst

    International Nuclear Information System (INIS)

    Peng Yongjun; Du Xiumei; Yuan Jinrong; Chen Chanqing

    2007-01-01

    Objective: To analyze the method and the curative effect with CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst. Method: 22 ovary cysts in 22 patients were treated with percutaneous puncture aspiration and underwent repeated sclerotherapy with 99.7% ethanol injection. Among the 22 patients, 18 patients had solitary ovary cyst and was aspirated with an 18-22G gauge aspiration needle. The amount of aspirated fluid varied from 30ml-500ml and 25%-30% cyst volume was replaced by appropriate ethanol Post treatment follow-up were achieved every 3 months. Results All the Punctures were successfully completed. During the 3 months to one year follow-up, 16 ovary cyst disappeared, 6 cysts were small over 50%, without main complication. Conclusion CT guided percutaneous puncture aspiration and sclerosing treatment of ovary cyst is a treatment of choice because of its safety, low complication, and high curative effect. (authors)

  3. CT- and MR-guided interventions in radiology. 2. ed.

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Wilhelm, Kai E.; Ricke, Jens

    2013-01-01

    Revised and extended second edition that covers a broad range of non-vascular interventions guided by CT or MR imaging. Discusses in detail indications, materials, techniques, and results. Includes a comprehensive section on interventional oncology. Richly illustrated source of information and guidance for all radiologists who deal with non-vascular procedures. Interventional radiology is an indispensable and still expanding area of modern medicine that encompasses numerous diagnostic and therapeutic procedures. Cross-sectional imaging modalities such as computed tomography (CT) and magnetic resonance (MR) have emerged as important techniques for non-vascular interventions, including percutaneous biopsy, drainage, ablation, and neurolysis. Various organs, diseases, and lesions can be approached in this way, permitting the treatment and management of tumors, fluid collections, and pain, the embolization of endoleaks, the provision of access to hollow organs, etc. Accordingly, interventional radiology is now an integral component of the interdisciplinary management of numerous disorders. The revised and significantly extended second edition of this volume covers a broad range of non-vascular interventions guided by CT or MR imaging. Indications, materials, techniques, and results are all carefully discussed. A particularly comprehensive section is devoted to interventional oncology as the most rapidly growing branch of interventional radiology. In addition, detailed information is provided that will assist in establishing and developing an interventional service. This richly illustrated book will be a most valuable source of information and guidance for all radiologists who deal with non-vascular procedures.

  4. Results and complications of CT-guided transthoracic fine-needle aspiration biopsy of pulmonary lesions

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Cristiano Dias de; Nunes, Rodolfo Acatauassu; Saito, Eduardo Haruo; Higa, Claudio; Cardona, Zanier Jose Fernando; Santos, Denise Barbosa dos, E-mail: cristianodiaslima@gmail.co [Hospital Universitario Pedro Ernesto (HUPE/UERJ), Rio de Janeiro, RJ (Brazil). Dept. Cirurgia Toracica

    2011-03-15

    Objective: to analyze the cytological findings of CT-guided percutaneous fine-needle aspiration biopsies of the lung, to demonstrate the diagnostic feasibility of the method in the investigation of pulmonary lesions, and to determine the complications of the procedure, evaluating its safety. Methods: a retrospective analysis of 89 patients with various types of pulmonary lesions who underwent 97 procedures over a period of five years. The patients were divided into groups regarding the indication for the procedure: suspicion of primary lung cancer (stages IIIB or IV); suspicion of lung cancer (stages I, II, or IIIA) and clinical contraindications for surgery; suspicion of pulmonary metastasis from other organs; and pulmonary lesions with benign radiological aspect. All of the procedures were performed with 25-gauge needles and were guided by spiral CT. The final diagnosis was confirmed by surgical biopsy and clinical/oncological follow-up. For the analysis of complications, the total number of procedures was considered. Results: the main indication for the procedure was suspicion of advanced stage primary lung cancer. The accuracy of the method for malignant lesions was 91.5%. The lesion was confirmed as cancer in 73% of the patients. The major complication was pneumothorax (27.8%), which required chest tube drainage in 12.4% of the procedures. Conclusions: the principal indication for CT-guided fine-needle biopsy was suspicion of primary lung cancer in patients who were not surgical candidates. The procedure has high diagnostic feasibility for malignant pulmonary diseases. The most prevalent complication was pneumothorax. However, in most cases, chest tube drainage was unnecessary. No deaths were related to the procedure. (author)

  5. Percutaneous transhepatic biliary drainage for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Qian Xiaojun; Jin Wenhui; Dai Dingke; Yu Ping; Gao Kun; Zhai Renyou

    2007-01-01

    Objective: To evaluate the effect of PTBD in treating malignant biliary obstruction caused by hilar cholangiocarcinoma. Methods: We retrospectively analyzed the data of 103 patients(M:62,F:41)with malignant obstructive jaundice caused by hilar cholangiocarcinoma. After taking percutaneous transhepatic cholangiography, metallic stent or plastic external catheter or external-internal catheter for drainage was deployed and then followed up was undertaken with clinical and radiographic evaluation and laboratory. examination. Results: All patients went though PTBD successfully (100%). According to Bismuth classification, all 103 cases consisted of I type(N=30), II type (N=30), III type (N=26) and IV type (N=17). Thirty-nine cases were placed with 47 stents and 64 eases with drainage tubes. 4 cases installed two stems for bilateral drainage, 2 cases installed two stents because of long segmental strictures with stent in stent, 1 case was placed with three stents, and 3 cases installed stent and plastic catheter together. Sixty-four cases received plastic catheters in this series, 35 cases installed two or more catheters for bilateral drainage, 28 cases installed external and internal drainage catheters, 12 eases installed external drainage catheters, and 24 eases installed both of them. There were 17 patients involving incorporative infection before procedure, 13 cases cured after procedure, and 15 new patients got inflammation after procedure. 13 cases showed increase of amylase (from May, 2004), 8 eases had bloody bile drainage and 1 case with pyloric obstruction. Total serum bilirubin reduced from (386 ± 162) μmol/L to (161 ± 117) μmol/L, (P<0.01) short term curative effect was related with the type of hilar cholangiocarcinoma. The survival time was 186 days(median), and 1, 3, 6, 12 month survival rate were 89.9%, 75.3%, 59.6%, 16.9%, respectively. Conclusion: Percutaneous transhepatic bile drainage is a safe and effective palliative therapy of malignant

  6. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  7. Value of CT-guided biopsy in malignant lymphoma; Wertigkeit der CT-gesteuerten Biopsie maligner Lymphome

    Energy Technology Data Exchange (ETDEWEB)

    Libicher, M.; Noeldge, G.; Radeleff, B.; Gholipur, F.; Richter, G.M. [Abteilung Radiodiagnostik, Universitaetsklinikum Heidelberg (Germany)

    2002-12-01

    Management of diagnosing malignant lymphomas has changed with development of CT-guided techniques and reliable biopsy tools.Pathologists can use representative tissue samples for sub classification in more than 90%.Evaluation of residual lymphoma or relapse can be nearly as effective. Therefore percutaneous biopsy can be considered as primary diagnostic tool in the absence of peripheral lymphadenopathy. CT-guided biopsies can be performed on an outpatient basis under conscious sedation considering contraindications as well as regional complications. Acceptance of percutaneous biopsy by the pathologist and oncologist is based on diagnostic effectiveness that is significantly improved if more than 3{dagger}solid tissue samples are taken. This article reviews the value of CT-guided biopsy in comparison to surgical procedures in patients with malignant lymphoma. Essential aspects that lead to a diagnostic percutaneous biopsy are discussed on grounds of the current literature. (orig.) [German] Mit der Entwicklung CT-gesteuerter Biopsieverfahren sowie zuverlaessiger Biopsiesysteme hat sich die Vorgehensweise bei der Diagnostik maligner Lymphome geaendert. Repraesentative Stanzzylinder mit hoher Praeparatequalitaet ermoeglichen dem Pathologen eine Subklassifikation der Lymphome in ueber 90%. Eine aehnlich hohe Treffsicherheit ist auch bei der Rezidivdiagnostik moeglich. Deshalb sind perkutane Biopsien bei fehlender peripherer Lymphadenopathie als primaere diagnostische Methode geeignet. Unter Beachtung der Kontraindikationen sowie der regional unterschiedlichen Komplikationsmoeglichkeiten koennen die meisten CT-gesteuerten Biopsien ambulant unter Analgosedierung durchgefuehrt werden. Die Akzeptanz perkutaner Biopsien durch Pathologen und Onkologen ist an die diagnostische Genauigkeit gekoppelt. Diese wird durch Gewinnung von mindestens 3 repraesentativen Biopsiezylindern aus den soliden Anteilen eines Lymphoms signifikant erhoeht. Die vorliegende Uebersichtsarbeit

  8. Percutaneous drainage of colonic diverticular abscess: is colon resection necessary?

    Science.gov (United States)

    Gaertner, Wolfgang B; Willis, David J; Madoff, Robert D; Rothenberger, David A; Kwaan, Mary R; Belzer, George E; Melton, Genevieve B

    2013-05-01

    Recurrent diverticulitis has been reported in up to 30% to 40% of patients who recover from an episode of colonic diverticular abscess, so elective interval resection is traditionally recommended. The aim of this study was to review the outcomes of patients who underwent percutaneous drainage of colonic diverticular abscess without subsequent operative intervention. This was an observational study. This investigation was conducted at a tertiary care academic medical center and a single-hospital health system. Patients treated for symptomatic colonic diverticular abscess from 2002 through 2007 were included. The primary outcomes measured were complications, recurrence, and colectomy-free survival. Two hundred eighteen patients underwent percutaneous drainage of colonic diverticular abscesses. Thirty-two patients (15%) did not undergo subsequent colonic resection. Abscess location was pelvic (n = 9) and paracolic (n = 23), the mean abscess size was 4.2 cm, and the median duration of percutaneous drainage was 20 days. The comorbidities of this group of patients included severe cardiac disease (n = 16), immunodeficiency (n = 7), and severe pulmonary disease (n = 6). Freedom from recurrence at 7.4 years was 0.58 (95% CI 0.42-0.73). All recurrences were managed nonoperatively. Recurrence was significantly associated with an abscess size larger than 5 cm. Colectomy-free survival at 7.4 years was 0.17 (95% CI 0.13-0.21). This study was limited by its retrospective, nonexperimental design and short follow-up. In selected patients, observation after percutaneous drainage of colonic diverticular abscess appears to be a safe and low-risk management option.

  9. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Min, Lingfeng; Xu, Xingxiang [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Song, Yong [Jinling Hospital, Nanjing University School of Medical, Nanjing 210002, Jiangsu (China); Issahar, Ben-Dov [Pulmonary Institute, Sheba Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv (Israel); Wu, Jingtao; Zhang, Le; Huang, Qian [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China); Chen, Mingxiang, E-mail: chenmx1129@126.com [Subei People' s Hospital of Jiangsu Province, Clinical Medical School of Yangzhou University, Yangzhou 225001, Jiangsu (China)

    2013-01-15

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study.

  10. Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy

    International Nuclear Information System (INIS)

    Min, Lingfeng; Xu, Xingxiang; Song, Yong; Issahar, Ben-Dov; Wu, Jingtao; Zhang, Le; Huang, Qian; Chen, Mingxiang

    2013-01-01

    Purpose: To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. Materials and methods: Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two hundred and twenty-one biopsies were performed without (control group) and two hundred and nineteen biopsies were performed with (study group) the study maneuver – a breath-hold after forced expiratory approach. Multivariate analysis was performed between groups for risk factors for pneumothorax, including patient demographics, lesion characteristics, and biopsy technique. Results: A reduced number of pneumothoraces (18 [8.2%] vs 35 [15.8%]; P = 0.014) but no significant difference in rate of drainage catheter insertions (2 [0.9%] vs (4 [1.8%]; P = 0.418) were noted in the study group as compared with the control group. By logistic regression analysis, three factors significantly and independently affected the risk for pneumothorax including lesion size (transverse and longitudinal diameter), distance from pleura and utilizing or avoiding the breath-hold after deep expiration maneuver. Conclusion: Breath-holding after forced expiration before removal of the biopsy needle during the percutaneous CT-guided transthoracic lung biopsy almost halved the rate of overall pneumothorax. Small lesion size (longitudinal diameter) and the distance from pleura were also predictors of pneumothorax in our study

  11. MR imaging-guided percutaneous cryotherapy for lung tumors: initial experience.

    Science.gov (United States)

    Liu, Shangang; Ren, Ruimei; Liu, Ming; Lv, Yubo; Li, Bin; Li, Chengli

    2014-09-01

    To evaluate prospectively the initial clinical experience of magnetic resonance (MR) imaging-guided percutaneous cryotherapy of lung tumors. MR imaging-guided percutaneous cryotherapy was performed in 21 patients with biopsy-proven lung tumors (12 men, 9 women; age range, 39-79 y). Follow-up consisted of contrast-enhanced chest computed tomography (CT) scan performed at 3-month intervals to assess tumor control; CT scanning was carried out for 12 months or until death. Cryotherapy procedures were successfully completed in all 21 patients. Pneumothorax occurred in 7 (33.3%) of 21 patients. Chest tube placement was required in one (4.8%) case. Hemoptysis was exhibited by 11 (52.4%) patients, and pleural effusion occurred in 6 (28.6%) patients. Other complications were observed in 14 (66.7%) patients. The mean follow-up period was 10.5 months (range, 9-12 mo) in patients who died. At month 12 of follow-up, 7 (33.3%) patients had a complete response to therapy, and 10 (47.6%) patients showed a partial response. In addition, two patients had stable disease, and two patients developed progressive disease; one patient developed a tumor in the liver, and the other developed a tumor in the brain. The 1-year local control rate was 81%, and 1-year survival rate was 90.5%. MR imaging-guided percutaneous cryotherapy appears feasible, effective, and minimally invasive for lung tumors. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  12. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent

    2012-01-01

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t’am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  13. Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

    Science.gov (United States)

    Tokuda, Junichi; Plishker, William; Torabi, Meysam; Olubiyi, Olutayo I; Zaki, George; Tatli, Servet; Silverman, Stuart G; Shekher, Raj; Hata, Nobuhiko

    2015-06-01

    Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registration process substantially. To achieve accurate and fast registration without the use of an ROI, we combined a nonrigid registration technique on the basis of volume subdivision with hardware acceleration using a graphics processing unit (GPU). We compared the registration accuracy and processing time of GPU-accelerated volume subdivision-based nonrigid registration technique to the conventional nonrigid B-spline registration technique. Fourteen image data sets of preprocedural MR and intraprocedural CT images for percutaneous CT-guided liver tumor ablations were obtained. Each set of images was registered using the GPU-accelerated volume subdivision technique and the B-spline technique. Manual contouring of ROI was used only for the B-spline technique. Registration accuracies (Dice similarity coefficient [DSC] and 95% Hausdorff distance [HD]) and total processing time including contouring of ROIs and computation were compared using a paired Student t test. Accuracies of the GPU-accelerated registrations and B-spline registrations, respectively, were 88.3 ± 3.7% versus 89.3 ± 4.9% (P = .41) for DSC and 13.1 ± 5.2 versus 11.4 ± 6.3 mm (P = .15) for HD. Total processing time of the GPU-accelerated registration and B-spline registration techniques was 88 ± 14 versus 557 ± 116 seconds (P processing time. The GPU-accelerated volume subdivision technique may enable the implementation of nonrigid registration into routine clinical practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  14. Comparison of infection between internal-external and external percutaneous transhepatic biliary drainage in treating patients with malignant obstructive jaundice.

    Science.gov (United States)

    Xu, Chuan; Huang, Xin-En; Wang, Shu-Xiang; Lv, Peng-Hua; Sun, Ling; Wang, Fu-An

    2015-01-01

    Percutaneous transhepatic biliary drainage (PTBD) is a form of palliative care for patients with malignant obstructive jaundice. We here compared the infection incidence between internal-external and external drainage for patients with malignant obstructive jaundice. Patients with malignant obstructive jaundice without infection before surgery receiving internal-external or external drainage from January 2008 to July 2014 were recruited. According to percutaneous transhepatic cholangiography (PTC), if the guide wire could pass through the occlusion and enter the duodenum, we recommended internal-external drainage, and external drainage biliary drainage was set up if the occlusion was not crossed. All patients with infection after procedure received a cultivation of blood and a bile bacteriological test. Among 110 patients with malignant obstructive jaundice, 22 (52.4%) were diagnosed with infection after the procedure in the internal-external drainage group, whereas 19 (27.9%) patients were so affected in the external drainage group, the difference being significant (pinternal-external group infection was controlled, as compared to 12 (63.1%) in the external group (pinternal-external group in one month was 42.8%, while this rate in external group was 28.6% (pExternal drainage is a good choice, which could significantly reduce the chance of biliary infection caused by bacteria, and decrease the mortality rate at one month and improve the long-term prognosis.

  15. Ultrasound guided transrectal catheter drainage of pelvic collections.

    Science.gov (United States)

    Thakral, Anuj; Sundareyan, Ramaniwas; Kumar, Sheo; Arora, Divya

    2015-01-01

    The transrectal approach to draining deep-seated pelvic collections may be used to drain The transrectal approach to draining deep-seated pelvic collections may be used to drain intra-abdominal collections not reached by the transabdominal approach. We discuss 6 patients with such pelvic collections treated with transrectal drainage using catheter placement via Seldinger technique. Transrectal drainage helped achieve clinical and radiological resolution of pelvic collections in 6 and 5 of 6 cases, respectively. It simultaneously helped avoid injury to intervening bowel loops and neurovascular structures using real-time visualization of armamentarium used for drainage. Radiation exposure from fluoroscopic/CT guidance was avoided. Morbidity and costs incurred in surgical exploration were reduced using this much less invasive ultrasound guided transrectal catheter drainage of deep-seated pelvic collections.

  16. Fatal paradoxical pulmonary air embolism complicating percutaneous computed tomography-guided needle biopsy of the lung

    International Nuclear Information System (INIS)

    Chakravarti, Rajesh; Singh, Virendra; Isaac, Rethish; John, Joseph

    2004-01-01

    A 63-year-old man with left upper zone haziness on chest X-ray and an infiltrative lesion with a pleural mass in the left upper lobe on CT scan was scheduled for CT-guided percutaneous trans-thoracic needle biopsy. During the procedure, the patient had massive haemoptysis and cardiorespiratory arrest and could not be revived. Post-mortem CT showed air in the right atrium, right ventricle, pulmonary artery and also in the left atrium and aorta. A discussion on paradoxical air embolism following percutaneous trans-thoracic needle biopsy is presented Copyright (2004) Blackwell Publishing Asia Pty Ltd

  17. Successful percutaneous transperineal drainage of a large prostatic abscess.

    Science.gov (United States)

    Mason, Barry M; Hakimi, A Ari; Clerkin, Kevin J; Silva, Jose V

    2010-12-01

    We present a case of an 83-year-old man with septic shock secondary to an extremely large prostatic abscess. Antibiotics and transperineal percutaneous drainage with a suprapubic-type Malecot catheter successfully treated the abscess. Follow-up images reveal resolution of the abscess. Broad-spectrum antibiotics and drainage permitted a full recovery. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. A self-retaining looped catheder for percutaneous biliary drainage

    International Nuclear Information System (INIS)

    Guenther, R.; Klose, K.; Daehnert, W.

    1983-01-01

    A percutaneous catheter which can be looped by means of a nylon thread was used in 32 patients for percutaneous biliary drainage. The catheter can be fixed in this way and is thereby prevented from migrating from the biliary system. The catheter is not suitable for proximal obstructions. Problems may arise during the removal of the nylon thread and loss of looping of the point of catheter. (orig.) [de

  19. Resolution of Postural Orthostatic Tachycardia Syndrome After CT-Guided, Percutaneous T2 Ethanol Ablation for Hyperhidrosis

    Energy Technology Data Exchange (ETDEWEB)

    Brock, Malcolm, E-mail: mabrock@jhmni.edu [Johns Hopkins University, Department of Thoracic Surgery, Center for Sweat Disorders (United States); Chung, Tae Hwan, E-mail: Tchang7@jhmi.edu [Johns Hopkins University, Physical Medicine and Rehabilitation (United States); Gaddam, Sathvika Reddy, E-mail: drsathvikareddy@yahoo.com; Kathait, Anjaneya Singh, E-mail: askathait@gmail.com [Johns Hopkins University, Vascular & Interventional Radiology (United States); Ober, Cecily, E-mail: ceober21@gmail.com [Johns Hopkins University, Department of Thoracic Surgery (United States); Georgiades, Christos, E-mail: cgeorgi@jhmi.edu [Johns Hopkins University, Vascular & Interventional Radiology (United States)

    2016-12-15

    Postural orthostatic tachycardia syndrome is characterized by orthostatic intolerance. Orthostasis (or other mild physical stress) triggers a cascade of inappropriate tachycardia, lightheadedness, palpitations, and often fainting. The underlying defect is sympathetic dysregulation of the heart, which receives its sympathetic tone from the cervical and upper thoracic sympathetic ganglia. Primary hyperhidrosis is also thought to be the result of sympathetic dysregulation. We present the case of a patient treated with CT-guided, percutaneous T2 EtOH sympatholysis for craniofacial hyperhidrosis. The patient also suffered from postural orthostatic tachycardia syndrome for many years and was unresponsive to treatment. Immediately after sympatholysis, the patient experienced resolution of both craniofacial hyperhidrosis and postural orthostatic tachycardia syndrome.

  20. Sclerosing encapsulating peritonitis in chronic ambulatory peritoneal dialysis;preoperative catheter drainage : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon [Dankook Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    Sclerosing encapsulating peritonitis is a well recognized, but uncommon, complication of chronic ambulatory peritoneal dialysis. I report a case of sclerosing encapsulating peritonitis in which percutaneous catheter drainage was performed preoperatively. Ultrasonography(US) and computed tomography(CT) showed a large multi-septated cystic mass which occupied nearly all the peritoneal cavity. Percutaneous drainage with two 8.5 French catheters was preoperatively performed under fluoroscopy and about 2100 ml of bloody fluid was drained for 20 days. On follow-up CT, the size of the cyst had significantly decreased and anoperation was performed. It is considered that percutaneous catheter drainage is useful in the preoperative decompression of sclerosing encapsulating peritonitis.

  1. Sclerosing encapsulating peritonitis in chronic ambulatory peritoneal dialysis;preoperative catheter drainage : a case report

    International Nuclear Information System (INIS)

    Kim, Tae Hoon

    1996-01-01

    Sclerosing encapsulating peritonitis is a well recognized, but uncommon, complication of chronic ambulatory peritoneal dialysis. I report a case of sclerosing encapsulating peritonitis in which percutaneous catheter drainage was performed preoperatively. Ultrasonography(US) and computed tomography(CT) showed a large multi-septated cystic mass which occupied nearly all the peritoneal cavity. Percutaneous drainage with two 8.5 French catheters was preoperatively performed under fluoroscopy and about 2100 ml of bloody fluid was drained for 20 days. On follow-up CT, the size of the cyst had significantly decreased and anoperation was performed. It is considered that percutaneous catheter drainage is useful in the preoperative decompression of sclerosing encapsulating peritonitis

  2. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  3. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  4. PET/CT-guided percutaneous biopsy of FDG-avid metastatic bone lesions in patients with advanced lung cancer: a safe and effective technique

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Wei; Hao, Bing; Chen, Hao-jun; Zhao, Long; Luo, Zuo-ming; Wu, Hua; Sun, Long [The First Affiliated Hospital of Xiamen University, Department of Nuclear Medicine and Minnan PET Center, Xiamen Cancer Hospital, Xiamen (China)

    2017-01-15

    {sup 18}F-FDG PET/CT should be performed before a diagnostic biopsy site is chosen in patients with a high clinical suspicion of aggressive, advanced tumour. The aim of this study was to evaluate the safety and efficacy of {sup 18}F-FDG PET/CT in guiding biopsy of bone metastases in patients with advanced lung cancer. PET/CT-guided percutaneous core biopsies were performed in 51 consecutive patients with suspected lung cancer and {sup 18}F-FDG-avid bone lesions after whole-body {sup 18}F-FDG PET/CT scans. Generally, one tissue sample was obtained from each patient. The final diagnoses were established on the basis of the histology results. The histopathological and molecular testing results were systematically evaluated. A total of 53 samples were obtained for histological examination or molecular testing as a second biopsy was required in two patients in whom the pathological diagnosis was unclear following the first biopsy. The pathological diagnosis and lung cancer classification were confirmed in 48 patients. The epidermal growth factor receptor mutation status was determined in 23 biopsies, and the mutation rate was 30.4 % (7/23). The anaplastic lymphoma kinase mutation status was determined in 19 biopsies, and the mutation rate was 31.6 % (6/19). Two of the 51 biopsies were positive for non-Hodgkin's lymphoma and one was positive for metastatic renal cell carcinoma. The first-time diagnostic success rate of biopsy was 96.1 % (49/51) and the overall diagnostic success rate and sensitivity were 100 %. All 51 patients were eventually confirmed as having stage IV disease. No serious complications were encountered and the average biopsy time was 30 min. PET/CT-guided percutaneous biopsy of {sup 18}F-FDG-avid bone metastases is an effective and safe method that yields a high diagnostic success rate in the evaluation of hypermetabolic bone lesions in patients with suspected advanced lung cancer. (orig.)

  5. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P. (Dept. of Spinal Surgery, Xian Red Cross Hospital, Xian Shaanxi (China)), email: zqpddn1@gmail.com; Sun, H.H. (Dept. of Orthopaedic, Tangdu Hospital, Fourth Military Medical Univ., Xian Shaanxi (China)); Jiang, Y.H. (Dept. of Radiology, Xian Red Cross Hospital, Xian Shaanxi (China))

    2011-11-15

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  6. Accuracy of CT-guided biopsies in 158 patients with thoracic spinal lesions

    International Nuclear Information System (INIS)

    Hao, D.J.; He, B.R.; Liu, T.J.; Zhao, Q.P.; Sun, H.H.; Jiang, Y.H.

    2011-01-01

    Background. Inconsistent accuracies of CT-guided thoracic spinal biopsies have been reported in previous studies. Purpose. To determine the accuracy of CT-guided thoracic spinal biopsy, to compare the results with those previously reported, and to determine if there are any factors that influence the accuracy of CT-guided thoracic spinal biopsy. Material and Methods. In total, 158 consecutive CT-guided percutaneous thoracic spine procedures (performed at the Dept. of Spinal Surgery, Xian Red Cross Hospital between April 2000 and July 2010) were reviewed. The 158 lesions were categorized by location and radiographic features. Pathological and clinical follow-up were used to determine accuracy. Results. The diagnostic accuracy of CT-guided thoracic spinal biopsy was 90.5% overall. Biopsy of metastatic bone disease (98.2%) was significantly more accurate than biopsies of primary tumors (80.9%) and of hematological malignancies (47.0%) (P < 0.05 and P < 0.005, respectively). The diagnostic accuracy of CT-guided thoracic spinal biopsy was significantly higher for the lower thoracic spine (97.6%) than for the middle (90.0%) or upper thoracic spine (80.4%) (P < 0.05 and P < 0.025, respectively). The diagnostic accuracy was significantly higher for lytic lesions (96.4%) than for sclerotic lesions (81.3%) (P < 0.010). The accuracy of biopsies performed using the transpedicular approach (91.0%) was not significantly different from that of biopsies performed using posterolateral approaches (91.5%) (0.25 < P < 0.5). Conclusion. Percutaneous CT-guided thoracic spinal biopsy is a viable alternative to open surgical biopsy. The diagnostic accuracy was not affected by any of the variables except for lesion level, histology, and radiographic features

  7. Clinical analysis and management of infections relative to percutaneous biliary drainage or stenting dilation

    International Nuclear Information System (INIS)

    Yu Ping; Dai Dingke; Qian Xiaojun; Zhai Renyou

    2007-01-01

    Objective: To analyze the occurrence of infectious relative to percutaneous biliary drainage (PTBD)or stenting for malignant obstructive jaundice and explore the therapy and prevention. Methods: 181 patients (130 male and 51 female; median age 64.5 years old) with malignant biliary obstructive jaundice were investigated including 81 hepatobiliary cancers, 42 pancreatico-ampullae tumors, 58 gestro-intestinal portal lymphatic metastasis. All cases accepted PTBD or placement of metallic stents and the perioperative complications were recorded and analysed including the occurance and treatment. Results: All cases accepted PTBD or stenting successfully. The perioperative biliary infection was the major complication including 50 out of 62 preoperative infected cases (34.25%). 18 cases (15.13%)suffered from biliary infection after operation with 13 under control, 5 without control, 4 complicated with pulmonary infection and 17 (9.39%)died of serious biliary infections. Gram-negative bacilli and endotoxin were the main cause of the severe biliary infection. Postoperative mild pancreatitis occurred in 65 cases (35.91%)without severe necrotic changes and were cured alter anti-inflammatory treatment. Hepatic abscess due to biliary leak occurred in 1 case (0.55%), and was cured by CT-guided drainage. Conclusion: Biliary infection is the most common complication after interventional therapy and should be promptly under control for preventing mortality and prolonging survival. Simultaneously, acute pancreatitis should also be on alert but good prognosis would be obtained with apt therapy. (authors)

  8. Study of percutaneous 125I seeds implantation guided by CT in elderly patients of stage I peripheral non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ke Mingyao; Yong Yazhi; Luo Bingqing; Wu Xuemei; Chen Lingling; Xie Hongqi

    2011-01-01

    Objective: To evaluate the efficacy, feasibility and safety of CT guided percutaneous 125 I seeds implantation in elderly patients of stage I peripheral non-small cell lung cancer (NSCLC). Methods: Clinical data of 16 elderly peripheral stage I NSCLC patients (10 squamous carcinoma and 6 adenocarcinoma; 13 stage I A and 3 stage I B ) who received radioactive 125 I seeds implantation because of refusal or being unsuited to operation or external radiotherapy were retrospectively analyzed. Prescribed dose was 140 - 160 Gy. Under CT guidance, 125 I seeds were implanted percutaneously into tumors for interstitial radiotherapy according to treatment plan system. Results: Mean number of 125 I seeds each patient received was 21.1. 12 complete response (CR) and 4 partial response (PR) were achieved. Total response rate (CR + PR) was 100%. 100% patients completed 10 to 56 months of follow-up, 15, 13, 8 and 6 patients completed 1-, 2-, 3-and 4-years' follow-up, respectively. The median local progression free time was 14 months. The 1-, 2-, 3-and 4-year overall survival rate were 60%, 54%, 50% and 33%, respectively (median : 14 months). 7 cases died of non-tumor disease and 5 died of metastasis. No severe complications were observed. Conclusions: CT guided 125 I seeds implantation is a safe, reliable and effective radical treatment method for elderly stage I peripheral NSCLC patients, who refuse to or are unsuitable to operation or external radiotherapy. (authors)

  9. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  10. Percutaneous balloon dilatation and long-term drainage as treatment of anastomotic and nonanastomotic benign biliary strictures

    NARCIS (Netherlands)

    Janssen, Jan Jaap; van Delden, Otto M.; van Lienden, Krijn P.; Rauws, Erik A. J.; Busch, Olivier R. C.; van Gulik, Thomas M.; Gouma, Dirk J.; Laméris, Johan S.

    2014-01-01

    This study was designed to determine the effectiveness of percutaneous balloon dilation and long-term drainage of postoperative benign biliary strictures. Medical records of patients with postoperative benign biliary strictures, in whom percutaneous transhepatic biliary drainage (PTBD) and balloon

  11. Computed tomography-guided percutaneous core needle biopsy of deep seated bone lesions in two dogs

    International Nuclear Information System (INIS)

    Mori, T.; Sakaida, M.; Yamada, M.; Akiyama, H.; Takai, Y.; Sakai, H.; Maruo, K.

    2006-01-01

    Computed Tomography (CT)-guided percutaneous core needle biopsies were undertaken for the diagnosis of osteosarcoma in the pelvis (case 1) and myeloma (case 2) in the seventh lumber vertebra which were difficult to targeted by palpation, ultrasound or fluoroscopy. In both cases, enough tissue for pathological diagnosis were obtained without any complication. CT-guided biopsy was thought to be a safe, easy and effective technique for the evaluation of the deep seated bone lesion

  12. Percutaneous transgastric irrigation drainage in combination with endoscopic necrosectomy in necrotizing pancreatitis (with videos).

    Science.gov (United States)

    Raczynski, Susanne; Teich, Niels; Borte, Gudrun; Wittenburg, Henning; Mössner, Joachim; Caca, Karel

    2006-09-01

    Endoscopic drainage of pancreatic acute and chronic pseudocysts and pancreatic necrosectomy have been shown to be beneficial for critically ill patients, with complete endoscopic resolution rates of around 80%. Our purpose was to describe an improved endoscopic technique used to treat pancreatic necrosis. Case report. University hospital. Two patients with large retroperitoneal necroses were treated with percutaneous transgastric retroperitoneal flushing tubes and a percutaneous transgastric jejunal feeding tube by standard percutaneous endoscopic gastrostomy access in addition to endoscopic necrosectomy. Intensive percutaneous transgastric flushing in combination with percutaneous normocaloric enteral nutrition and repeated endoscopic necrosectomy led to excellent outcomes in both patients. Small number of patients. The "double percutaneous endoscopic gastrostomy" approach for simultaneous transgastric drainage and normocaloric enteral nutrition in severe cases of pancreatic necroses is safe and effective. It could be a promising improvement to endoscopic transgastric treatment options in necrotizing pancreatitis.

  13. A percutaneous drainage protocol for severe and moderately severe acute pancreatitis.

    Science.gov (United States)

    Sugimoto, Motokazu; Sonntag, David P; Flint, Greggory S; Boyce, Cody J; Kirkham, John C; Harris, Tyler J; Carr, Sean M; Nelson, Brent D; Barton, Joshua G; Traverso, L William

    2015-11-01

    According to the revised Atlanta classification, severe and moderately severe acute pancreatitis (AP) includes patients with pancreatic and peripancreatic collections with or without organ failure. These collections suggest the presence of pancreatic juice leakage. The aim of this study was to evaluate the efficacy of a percutaneous catheter drainage (PCD) protocol designed to control leakage and decrease disease severity. Among 663 patients with clinical AP, 122 were classified as moderately severe or severe AP (all had collections). The computed tomography severity index (CTSI) score was calculated. The indication for PCD was based on progressive clinical signs and symptoms. Drain patency, position, and need for additional drainage sites were assessed using CT scans and drain studies initially every 3 days using a proactive protocol. Drain fluid was examined for amylase concentration and microbiological culture. Clinicopathological variables for patients with and without PCD were compared. Since there was no mortality, we used prolonged drainage time to measure the success of PCD. Within the group treated with PCD, variables that resulted in prolonged drainage time were analyzed. PCD was used in 47/122 (39 %) patients of which 33/47 (70 %) had necrosis. PCD cases had a median CTSI of 8 and were classified as moderately severe AP (57 %) and severe AP (43 %). Inhospital mortality was zero. Surgical necrosectomy was not required for patients with necrosis. Independent risk factors for prolonged drainage time were persistent organ failure >48 h (P = 0.001), CTSI 8-10 (P = 0.038), prolonged duration of amylase-rich fluid in drains (P drainage fluid resulting in a mortality rate of zero.

  14. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  15. Neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia.

    Science.gov (United States)

    Zhang, W C; Zhong, W X; Li, S T; Zheng, X S; Yang, M; Shi, J

    2012-03-01

    Although radiofrequency thermocoagulation is considered as a primary treatment for most patients with trigeminal neuralgia, neuronavigator-guided percutaneous radiofrequency thermocoagulation has been rarely reported. The object of this study was to assess the clinical value of neuronavigator-guided percutaneous radiofrequency thermocoagulation in the treatment of trigeminal neuralgia. The radiofrequency thermocoagulation was performed in 100 cases of trigeminal neuralgia. The patients were positioned supine or sitting, under Hartel's technique (reported by Sweet and Wepsic J Neurosurg 40:143-156, 1974), by anterior lateral facial approaches. The Gasserian ganglions were acupunctured, assisted by intraoperative CT scanning (3-digital reconstruction) and electrophysiology in order to accurately locate target. The needles located in oval foramen at the first puncture, the direction and position could be defined according to the electrophysiology examination. The pain alleviated immediately after operation. There occurred no serious complication and other nerve injury in all patients despite face numbness only. 3D-CT and electrophysiology Gasser's ganglion locations can raise the success rate of puncture, enhance the safety and reduce the incidence of complication, showing high academic value and its promising future.

  16. Interactive navigation-guided ophthalmic plastic surgery: the utility of 3D CT-DCG-guided dacryolocalization in secondary acquired lacrimal duct obstructions

    Directory of Open Access Journals (Sweden)

    Ali MJ

    2016-12-01

    Full Text Available Mohammad Javed Ali,1 Swati Singh,1 Milind N Naik,1 Swathi Kaliki,2 Tarjani Vivek Dave1 1Govindram Seksaria Institute of Dacryology, 2The Operation Eyesight Universal Institute for Eye Cancer, L V Prasad Eye Institute, Hyderabad, Telangana, India Aim: The aim of this study was to report the preliminary experience with the techniques and utility of navigation-guided, 3D, computed tomography–dacryocystography (CT-DCG in the management of secondary acquired lacrimal drainage obstructions.Methods: Stereotactic surgeries using CT-DCG as the intraoperative image-guiding tool were performed in 3 patients. One patient had nasolacrimal duct obstruction (NLDO following a complete maxillectomy for a sinus malignancy, and the other 2 had NLDO following extensive maxillofacial trauma. All patients underwent a 3D CT-DCG. Image-guided dacryolocalization (IGDL was performed using the intraoperative image-guided StealthStation™ system in the electromagnetic mode. All patients underwent navigation-guided powered endoscopic dacryocystorhinostomy (DCR. The utility of intraoperative dacryocystographic guidance and the ability to localize the lacrimal drainage system in the altered endoscopic anatomical milieu were noted.Results: Intraoperative geometric localization of the lacrimal sac and the nasolacrimal duct could be easily achieved. Constant orientation of the lacrimal drainage system was possible while navigating in the vicinity of altered endoscopic perilacrimal anatomy. Useful clues with regard to modifications while performing a powered endoscopic DCR could be obtained. Surgeries could be performed with utmost safety and precision, thereby avoiding complications. Detailed preoperative 3D CT-DCG reconstructions with constant intraoperative dacryolocalization were found to be essential for successful outcomes.Conclusion: The 3D CT-DCG-guided navigation procedure is very useful while performing endoscopic DCRs in cases of secondary acquired and complex

  17. Image-Guided Transvesicular Drainage of Pelvic Fluid Collections: A Safe and Effective Alternative Approach.

    Science.gov (United States)

    Ayyagari, Raj R; Yeh, Cliff; Arici, Melih; Mojibian, Hamid; Reiner, Eric; Pollak, Jeffrey S

    2016-05-01

    To evaluate the safety and efficacy of percutaneous transvesicular drainage of pathologic pelvic fluid collections, a series of 15 patients who underwent 16 transvesicular drainage catheter placements was retrospectively reviewed. All patients had collections suspicious for infection that were posterior to the bladder or superior to the bladder behind loops of bowel, and were otherwise inaccessible. All 15 collections were percutaneously accessed via the bladder with standard drainage catheters. All collections resolved completely with no complications. Percutaneous transvesicular drainage was a safe and effective technique in this series, and can be considered when no direct percutaneous access routes are available. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  18. Percutaneous treatment in patients presenting with malignant cardiac tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Marcy, P.Y. [Antoine Lacassagne Center, Interventional Radiology Department, Nice (France); Bondiau, P.Y. [Antoine Lacassagne Center, Radiation Therapy Department, Nice (France); Brunner, P. [Centre Hospitalier Princesse, Grace (Monaco). Interventional Radiology Department

    2005-09-01

    The percutaneous treatment of pericardial effusion resulting in cardiac tamponade has undergone an evolution in recent years with the use of less invasive drainage techniques in selected cases. To determine optimal therapy modalities for oncology patients with malignant pericardial tamponade (MPT), the authors review their institutional experience with percutaneous needle puncture routes, means of imaging-guided drainage and percutaneous management of the pericardial fluid effusion (pericardial sclerosis and balloon pericardiotomy). Advantages and limits of the percutaneous techniques will be compared to the surgical treatment. (orig.)

  19. Ultrasound guided percutaneous fine needle aspiration biopsy ...

    African Journals Online (AJOL)

    )-guided percutaneous fine needle aspiration biopsy (PFNAB)/US-guided percutaneous needle core biopsy (PNCB) of abdominal lesions is efficacious in diagnosis, is helpful in treatment choice, to evaluate whether various other investigations ...

  20. Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint

    International Nuclear Information System (INIS)

    Becce, Fabio; Mouhsine, Elyazid; Mosimann, Pascal John; Anaye, Anass; Letovanec, Igor; Theumann, Nicolas

    2012-01-01

    Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography—guided retrograde drilling and debridement.

  1. Percutaneous CT-Guided Treatment of Osteochondritis Dissecans of the Sacroiliac Joint

    Energy Technology Data Exchange (ETDEWEB)

    Becce, Fabio, E-mail: fabio.becce@chuv.ch [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland); Mouhsine, Elyazid [Clinique Hirslanden Bois-Cerf, Department of Orthopaedic Surgery (Switzerland); Mosimann, Pascal John; Anaye, Anass [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland); Letovanec, Igor [University Institute of Pathology, Centre Hospitalier Universitaire Vaudois (Switzerland); Theumann, Nicolas [University of Lausanne, Department of Diagnostic and Interventional Radiology, Centre Hospitalier Universitaire Vaudois (Switzerland)

    2012-08-15

    Osteochondritis dissecans (OCD) is a joint disorder that affects the articular cartilage and subchondral bone, most commonly at the knee. OCD of the sacroiliac joint is extremely rare. Management of OCD remains controversial, and surgery is often needed, especially when conservative treatment fails. We present a rare case of OCD involving the left sacroiliac joint successfully treated by percutaneous computed tomography-guided retrograde drilling and debridement.

  2. Major complications of high-energy microwave ablation for percutaneous CT-guided treatment of lung malignancies: single-centre experience after 4 years

    International Nuclear Information System (INIS)

    Splatt, Alexander M.; Steinke, Karin

    2015-01-01

    To evaluate the rate of major complications related to percutaneous computed tomography (CT)-guided microwave ablation (MWA) of primary and secondary lung malignancies performed at our institution over a 4-year period. From May 2010 to September 2014, 70 MWAs were performed on 51 patients. All major intra- and post-procedural complications (as defined by the classification proposed by the Society of Interventional Radiology) were retrospectively analysed. The results were correlated with a systematic review of the available literature on MWA in the lung. Major complications were encountered in 14 out of 70 ablations (20%). Twenty-one separate major complications were encountered (some ablations lead to more than one major complication). One death occurred within 30 days of ablation, though the relationship to the procedure remains uncertain. Other major complications included: nine pneumothoraces requiring drain insertion (12.9%), four cases of large effusion requiring drainage (5.7%), two cases of significant pulmonary haemorrhage altering clinical management (2.9%), two infections (2.9%), one case of mechanical failure (1.4%), one chest wall burn (1.4%) and one case of pleural seeding (1.4%). Major complications were much more likely to occur if the nodule was located within 7 mm from the pleura. MWA of pulmonary tumours carries moderate risk; nevertheless, the usually manageable complications should not deter from undertaking a potentially curative therapy for poor surgical candidates.

  3. Emergent radiologically guided drainage of large pericardial effusions

    International Nuclear Information System (INIS)

    Hartz, W.H.; Gatenby, R.A.; Kessler, H.B.

    1987-01-01

    The authors drained eight pericardial effusions on an emergency basis because of profound symptoms of pericardial tamponade. The etiology of the pericardial was metastatic disease in all eight cases. US of the subxyphoid region allowed definition of an optimal percutaneous approach. The pericardium was initially punctured with a 22-gauge needle, followed by tract dilation over a wire, which allowed ultimate placement of either an 8.4-F or 10-F nephrostomy catheter. Some 500 - 1,500 ml of bloody fluid drained from the pericardial space within minutes, and a total of 2 - 4 L over the next 4 days. No significant arrhythmias or immediate hypotensive episodes were observed. Six of the patients were successfully treated with sclerosis of the pericardium by injection of tetracyline into the pericardial catheter before it was removed. No recurrent effusions have been observed in any of these patients. Two patients died, one of unsuspected cerebral edema and uncal herniation and one of intractable congestive heart failure. At autopsy, the pericardial catheter was properly positioned with no significant remaining fluid. Echocardiograms were falsely normal in two patients, but CT findings were uniformly diagnostic. Radiologically guided drainage of large pericardial effusions appears to be a safe and effective technique for the treatment of pericardial tamponade from metastatic effusions. This technique is an alternative to the usual surgical intervention and does not require general anesthesia

  4. Percutaneous Management of Abscess and Fistula Following Pancreaticoduodenectomy

    International Nuclear Information System (INIS)

    AAssar, O. Sami; LaBerge, Jeanne M.; Gordon, Roy L.; Wilson, Mark W.; Mulvihill, Sean J.; Way, Lawrence W.; Kerlan, Robert K.

    1999-01-01

    Purpose: To evaluate the efficacy of percutaneous drainage of fluid collections following pancreaticoduodenectomy (Whipple's procedure). Methods: We performed a retrospective review of 19 patients referred to our service with fluid collections following pancreaticoduodenectomy. The presence of associated enteric or biliary fistulas, the route(s) of access for image-guided drainage, the incidence of positive bacterial cultures, and the duration and success of percutaneous management were recorded. Results: Fistulous communication to the jejunum in the region of the pancreatico-jejunal anastomosis was demonstrable in all 19 patients by gentle contrast injection into drainage tubes. Three patients had concurrent biliary fistulas. In 18 of 19 patients, fluid samples yielded positive bacterial cultures. Successful percutaneous evacuation of fluid was achieved in 17 of 19 patients (89%). The mean duration of drainage was 31 days. Conclusion: Percutaneous drainage of abscess following pancreaticoduodenectomy is effective in virtually all patients despite the coexistence of enteric and biliary fistulas

  5. PET/CT-guided interventions: Indications, advantages, disadvantages and the state of the art.

    Science.gov (United States)

    Cazzato, Roberto Luigi; Garnon, Julien; Shaygi, Behnam; Koch, Guillaume; Tsoumakidou, Georgia; Caudrelier, Jean; Addeo, Pietro; Bachellier, Philippe; Namer, Izzie Jacques; Gangi, Afshin

    2018-02-01

    Positron emission tomography/computed tomography (PET/CT) represents an emerging imaging guidance modality that has been applied to successfully guide percutaneous procedures such as biopsies and tumour ablations. The aim of the present narrative review is to report the indications, advantages and disadvantages of PET/CT-guided procedures in the field of interventional oncology and to briefly describe the experience gained with this new emerging technique while performing biopsies and tumor ablations.

  6. Arterial Complications of Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    L'Hermine, Claude; Ernst, Olivier; Delemazure, Olivier; Sergent, Geraldine

    1996-01-01

    Purpose: To report on the frequency and treatment of arterial complications due to percutaneous transhepatic biliary drainage (PTBD).Materials: Lesions of the intrahepatic artery were encountered in 10 of 525 patients treated by PTBD (2%). Hemobilia followed in 9 patients and subcapsular hematoma in 1. Seven patients had a benign biliary stenosis and 3 had a malignant stenosis.Results: The bleeding resolved spontaneously in 3 patients. In 7 it required arterial embolization, which was successfully achieved either through the percutaneous catheter (n= 3) or by arteriography (n= 4).Conclusion: Arterial bleeding is a relatively rare complication of PTBD that can easily be treated by selective arterial embolization when it does not resolve spontaneously. In this series its frequency was much higher (16%) when the stenosis was benign than when it was malignant (0.6%)

  7. Percutaneous drainage without sclerotherapy for benign ovarian cysts.

    Science.gov (United States)

    Zerem, Enver; Imamović, Goran; Omerović, Safet

    2009-07-01

    To evaluate percutaneous short-term catheter drainage in the management of benign ovarian cysts in patients at increased surgical risk. Thirty-eight patients with simple ovarian cysts were treated with drainage of fluid content by catheters until output stopped. All patients were poor candidates for surgery. All procedures were performed under ultrasonographic (US) control and local anesthesia. Cytologic examination was performed in all cases. The patients were followed up monthly with color Doppler US for 12 months. Outcome measure was the recurrence of a cyst. During the 12-month follow-up period, 10 of 38 cysts recurred. Seven of the 10 cysts required further intervention, and three were followed up without intervention. Four of the seven patients who required further intervention underwent repeat transabdominal aspiration and three declined repeat aspiration and subsequently underwent surgery. After repeated aspirations, two of four cysts disappeared, one necessitated follow-up only, and one necessitated surgical intervention. Cyst volume (P = .009) and diameter (P = .001) were significantly larger in the cysts that recurred. No evidence of malignancy was reported in the cytologic examination in any patient. No patients developed malignancy during follow-up. No major complications were observed. The hospital stay was 1 day for all patients. The median duration of drainage in the groups with resolved and recurrent cysts was 1 day (interquartile range, 1-1) and 2 days (interquartile range, 1-3), respectively (P = .04). In patients considered poor candidates for open surgery or laparoscopy, percutaneous treatment of ovarian cysts with short-term catheter drainage without sclerotherapy appears to be a safe and effective alternative, with low recurrence rates.

  8. Computed tomography-guided percutaneous trephine removal of the nidus in osteoid osteoma patients: experience of a single center in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Petrilli, Marcelo; Senerchia, Andreza Almeida; Petrilli, Antonio Sergio; Lederman, Henrique Manoel; Garcia Filho, Reynaldo Jesus, E-mail: andrezasenerchia@hotmail.com [Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil). Instituto de Oncologia Pediatrica

    2015-07-15

    Objective: to report the results of computed tomography (CT)-guided percutaneous resection of the nidus in 18 cases of osteoid osteoma. Materials and methods: the medical records of 18 cases of osteoid osteoma in children, adolescents and young adults, who underwent CT-guided removal of the nidus between November, 2004 and March, 2009 were reviewed retrospectively for demographic data, lesion site, clinical outcome and complications after procedure. Results: clinical follow-up was available for all cases at a median of 29 months (range 6-60 months). No persistence of pre-procedural pain was noted on 17 patients. Only one patient experienced recurrence of symptoms 12 months after percutaneous resection, and was successfully retreated by the same technique, resulting in a secondary success rate of 18/18 (100%). Conclusion: CT-guided removal or destruction of the nidus is a safe and effective alternative to surgical resection of the osteoid osteoma nidus. (author)

  9. Initial Results of Image-Guided Percutaneous Ablation as Second-Line Treatment for Symptomatic Vascular Anomalies

    International Nuclear Information System (INIS)

    Thompson, Scott M.; Callstrom, Matthew R.; McKusick, Michael A.; Woodrum, David A.

    2015-01-01

    PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5) for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA

  10. Initial Results of Image-Guided Percutaneous Ablation as Second-Line Treatment for Symptomatic Vascular Anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Scott M., E-mail: Thompson.scott@mayo.edu [Mayo Clinic, Mayo Graduate School, Mayo Medical School and the Mayo Clinic Medical Scientist Training Program, College of Medicine (United States); Callstrom, Matthew R., E-mail: callstrom.matthew@mayo.edu; McKusick, Michael A., E-mail: mckusick.michael@mayo.edu; Woodrum, David A., E-mail: woodrum.david@mayo.edu [Mayo Clinic, Department of Radiology, College of Medicine (United States)

    2015-10-15

    PurposeThe purpose of this study was to determine the feasibility, safety, and early effectiveness of percutaneous image-guided ablation as second-line treatment for symptomatic soft-tissue vascular anomalies (VA).Materials and MethodsAn IRB-approved retrospective review was undertaken of all patients who underwent percutaneous image-guided ablation as second-line therapy for treatment of symptomatic soft-tissue VA during the period from 1/1/2008 to 5/20/2014. US/CT- or MRI-guided and monitored cryoablation or MRI-guided and monitored laser ablation was performed. Clinical follow-up began at one-month post-ablation.ResultsEight patients with nine torso or lower extremity VA were treated with US/CT (N = 4) or MRI-guided (N = 2) cryoablation or MRI-guided laser ablation (N = 5) for moderate to severe pain (N = 7) or diffuse bleeding secondary to hemangioma–thrombocytopenia syndrome (N = 1). The median maximal diameter was 9.0 cm (6.5–11.1 cm) and 2.5 cm (2.3–5.3 cm) for VA undergoing cryoablation and laser ablation, respectively. Seven VA were ablated in one session, one VA initially treated with MRI-guided cryoablation for severe pain was re-treated with MRI-guided laser ablation due to persistent moderate pain, and one VA was treated in a planned two-stage session due to large VA size. At an average follow-up of 19.8 months (range 2–62 months), 7 of 7 patients with painful VA reported symptomatic pain relief. There was no recurrence of bleeding at five-year post-ablation in the patient with hemangioma–thrombocytopenia syndrome. There were two minor complications and no major complications.ConclusionImage-guided percutaneous ablation is a feasible, safe, and effective second-line treatment option for symptomatic VA.

  11. Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Im [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Kyung Hee University Hospital at Gangdong, Kyung Hee University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of)

    2015-07-15

    To investigate the effect of rapid needle-out patient-rollover approach on the incidence of pneumothorax and drainage catheter placement due to pneumothorax in C-arm Cone-beam CT (CBCT)-guided percutaneous transthoracic needle biopsy (PTNB) of lung lesions. From May 2011 to December 2012, 1227 PTNBs were performed in 1191 patients with a 17-gauge coaxial needle. 617 biopsies were performed without (conventional-group) and 610 with rapid-rollover approach (rapid-rollover-group). Overall pneumothorax rates and incidences of pneumothorax requiring drainage catheter placement were compared between two groups. There were no significant differences in overall pneumothorax rates between conventional and rapid-rollover groups (19.8 % vs. 23.1 %, p = 0.164). However, pneumothorax rate requiring drainage catheter placement was significantly lower in rapid-rollover-group (1.6 %) than conventional-group (4.2 %) (p = 0.010). Multivariate analysis revealed male, age > 60, bulla crossed, fissure crossed, pleura to target distance > 1.3 cm, emphysema along needle tract, and pleural punctures ≥ 2 were significant risk factors of pneumothorax (p < 0.05). Regarding pneumothorax requiring drainage catheter placement, fissure crossed, bulla crossed, and emphysema along needle tract were significant risk factors (p < 0.05), whereas rapid-rollover approach was an independent protective factor (p = 0.002). The rapid needle-out patient-rollover approach significantly reduced the rate of pneumothorax requiring drainage catheter placement after CBCT-guided PTNB. (orig.)

  12. CT guided interventional therapy for hypertensive cerebral hemorrhage

    International Nuclear Information System (INIS)

    Lin Bo; Duan Bing

    2009-01-01

    Objective: To discuss the curative effect of CT-guided puncture and drainage in treating hypertensive cerebral hemorrhage. Methods: Adjusting the suitable point and direction of puncture according to the form and size of the haematoma and patient's status, the haematoma was eliminated by minimally invasive puncture and drainage guided under CT layer image in 40 cases of hypertensive cerebral hemorrhage. Results: Modality rate of treatment group was 12.5% (5/40), and is much lower than control group, which was 45% (13/30) (P<0.01). When asscess the Activities of Daily Living (ADL) after 6 months follow-up, the ADL1-ADL3 scale in treatment group was 27 cases (70%), and was much higher than that in control group, which was 29.4% (5/17), (P < 0.05). Conclusion: Minimal invasive therapy of cerebral hemorrhage has great superiority in elimination most part of the hematoma such as simple, accurate location, low cost, safe and effective, and is worthy of recommendation clinically. (authors)

  13. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik [College of Medicine, Kyungpook National Univ., Daegu (Korea, Republic of)

    1990-10-15

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient.

  14. Percutaneous transhepatic biliary drainage: analysis of 175 cases

    International Nuclear Information System (INIS)

    Suh, Kyung Jin; Lee, Sang Kwon; Kim, Tae Hun; Kim, Yong Joo; Kang, Duk Sik

    1990-01-01

    Percutaneous transhepatic biliary drainage is a safe, effective and palliative means of treatment in biliary obstruction, especially in cases with malignant obstruction which are inoperable. 175 cases of transhepatic biliary drainage were performed on 119 patients with biliary obstruction from January 1985 to June 1989 at Kyung-pook National University Hospital. The causes of obstructive jaundice were 110 malignant diseases and 9 benign diseases. The most common indication for drainage was palliative intervention of obstruction secondary to malignant tumor in 89 cases. 86 cases of external drainage were performed including 3 cases of left duct approach, 29 cases of external-internal drainage and 60 cases of endoprosthesis. In external and external-internal drainages, immediate major complications (11.9%) occurred, including not restricted to, but sepsis, bile peritonitis and hemobilia. Delayed major complications (42.9%) were mainly catheter related. The delayed major complication of endoprosthesis resulted from obstruction of the internal stent. The mean time period to reobstruction of the internal stent was about 12 weeks. To improve management status, regular follow-up is required, as is education of both patients and their families as to when immediate clinical attention is mandated. Close communication amongst the varying medical specialities involved will be necessary to provide optional treatment for each patient

  15. Interventional therapy of hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage

    International Nuclear Information System (INIS)

    Liang Songnian; Feng Bo; Su Hongying; Xu Ke

    2011-01-01

    Objective: To analyze the causes and clinical manifestations of hepatic arterial hemorrhage which occurred after percutaneous transhepatic biliary drainage and to summarize the practical experience in its diagnosis and treatment in order to decrease its incidence and mortality. Methods: During the period from June 2007 to June 2010, percutaneous transhepatic biliary drainage was carried out in 622 cases, of which DSA-proved postoperative hepatic arterial hemorrhage occurred in 11, including bile duct hemorrhage (n=6), abdominal cavity bleeding (n=3) and combination of bile duct and abdominal cavity (n=2). Interventional embolization of the bleeding branches of hepatic artery with Gelfoam and coils was carried out in all 11 patients. The clinical data such as clinical manifestations and therapeutic results were retrospectively analyzed. Results: After interventional embolization therapy for postoperative hepatic arterial hemorrhage the bleeding stopped in ten patients, who were discharged from hospital when the clinical conditions were alleviated. The remaining one patient died of sustained deterioration in hepatic and renal functions although the bleeding was ceased. Conclusion: Though hepatic arterial hemorrhage occurred after percutaneous transhepatic biliary drainage is a rare complication, it is dangerous and fatal. Hepatic arterial angiography together with interventional embolization is a sate and effective therapy for hepatic arterial hemorrhage. (authors)

  16. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    International Nuclear Information System (INIS)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R.

    2006-01-01

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features

  17. Diagnosing pancreatic cancer: the role of percutaneous biopsy and CT

    Energy Technology Data Exchange (ETDEWEB)

    Amin, Z.; Theis, B.; Russell, R.C.G.; House, C.; Novelli, M.; Lees, W.R

    2006-12-15

    Aims: To determine the sensitivity and complications of percutaneous biopsy of pancreatic masses, and whether typical computed tomography (CT) features of adenocarcinoma can reliably predict this diagnosis. Materials and methods: A 5 year retrospective analysis of percutaneous core biopsies of pancreatic masses and their CT features was undertaken. Data were retrieved from surgical/pathology databases; medical records and CT reports and images. Results: Three hundred and three patients underwent 372 biopsies; 56 of 87 patients had repeat biopsies. Malignancy was diagnosed in 276 patients, with ductal adenocarcinoma in 259 (85%). Final sensitivity of percutaneous biopsy for diagnosing pancreatic neoplasms was 90%; for repeat biopsy it was 87%. Complications occurred in 17 (4.6%) patients, in three of whom the complications were major (1%): one abscess, one duodenal perforation, one large retroperitoneal bleed. CT features typical of ductal adenocarcinoma were: hypovascular pancreatic mass with bile and/or pancreatic duct dilatation. Atypical CT features were: isodense or hypervascular mass, calcification, non-dilated ducts, cystic change, and extensive lymphadenopathy. Defining typical CT features of adenocarcinoma as true-positives, CT had a sensitivity of 68%, specificity of 95%, positive predictive value (PPV) of 98%, and negative predictive value of 41% for diagnosing pancreatic adenocarcinoma. Conclusion: Final sensitivity of percutaneous biopsy for establishing the diagnosis was 90%. CT features typical of pancreatic adenocarcinoma had high specificity and PPV. On some occasions, especially in frail patients with co-morbidity, it might be reasonable to assume a diagnosis of pancreatic cancer if CT features are typical, and biopsy only if CT shows atypical features.

  18. Percutaneous CT-guided lung biopsy: sequential versus spiral scanning. A randomized prospective study

    International Nuclear Information System (INIS)

    Ghaye, B.; Dondelinger, R.F.; Dewe, W.

    1999-01-01

    The aim of this study was to evaluate in a prospective and randomized study spiral versus sequential scanning in the guidance of percutaneous lung biopsy. Fifty thoracic lesions occurring in 48 patients were biopsied by a senior and a junior operator. Six different time segments of the procedure were measured. Scanning mode versus length of procedure, pathological results, irradiation and complications were evaluated. Total duration of the procedure and of the first sampling was significantly longer with spiral CT for the senior operator (p < 0.004). No significant time difference was observed for the junior operator. Diameter of the lesion, depth of location, position of the patient and needle entry site did not influence the results. The sensitivity was 90.9, specificity 100, positive predictive value 100 and negative predictive value 60 % for spiral CT, and 94.7, 100, 100 and 85.7 % for sequential CT, respectively. Eleven pneumothoraces and ten perinodular hemorrhages were seen with spiral CT and six and ten, respectively, with sequential CT. The mean dose of irradiation was 4027 mAs for spiral CT and 2358 mAs for conventional CT. Spiral CT does neither reduce procedure time nor the rate of complications. Pathological results do not differ compared with sequential CT, and total dose of irradiation is higher with spiral scanning. (orig.)

  19. Systemic Air Embolism After CT-guided Lung Biopsy

    Science.gov (United States)

    2017-11-27

    Patients Who Underwent Percutaneous Lung Biopsy Under CT Guidance; Patients Who Presented Systemic Air Embolism After Percutaneous Lung Biopsy Under CT Guidance Depicted at the Time of the Procedure on a Whole Thoracic CT

  20. Understanding the Lung Abscess Microbiome: Outcomes of Percutaneous Lung Parenchymal Abscess Drainage with Microbiologic Correlation.

    Science.gov (United States)

    Duncan, Christopher; Nadolski, Gregory J; Gade, Terence; Hunt, Stephen

    2017-06-01

    Lung parenchymal abscesses represent an uncommon pathology with high mortality if untreated. Although most respond well to antibiotics, the optimal therapy for persistent abscesses is unknown. The purpose of this study was to review the outcomes of percutaneous lung parenchymal abscess catheter drainage after broad-spectrum antibiotic therapy failure and correlate with patient microbiologic samples. Retrospective review of patients who underwent percutaneous lung abscess drainage at a tertiary hospital system from 2005 to 2015 was performed. In total, 19 procedures were identified on 16 different patients; six females and ten males. Mean patient age was 55 years (range 22-81). Median follow-up time was 7 months (range abscess cavity in 58% (11/19) or with non-draining abscess cavities in 21% (4/19) for a clinical success rate of 79%. Blood cultures demonstrated no growth in all cases, while 21% (4/19) of sputum or bronchoscopic cultures demonstrated growth. In comparison, the specimens from initial catheter placement isolated a causative organism in 95% (18/19) of case (p lung abscess after broad-spectrum antibiotics, percutaneous abscess drainage is highly sensitive for microbiologic sampling compared to sputum/bronchoscopic or blood cultures. Additionally, percutaneous drainage of lung parenchymal abscess cavities may promote resolution of the abscess with high rates of therapeutic success and low complications.

  1. A comparison between endoscopic ultrasound-guided rendezvous and percutaneous biliary drainage after failed ERCP for malignant distal biliary obstruction.

    Science.gov (United States)

    Bill, Jason G; Darcy, Michael; Fujii-Lau, Larissa L; Mullady, Daniel K; Gaddam, Srinivas; Murad, Faris M; Early, Dayna S; Edmundowicz, Steven A; Kushnir, Vladimir M

    2016-09-01

    Selective biliary cannulation is unsuccessful in 5 % to 10 % of patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) for malignant distal biliary obstruction (MDBO). Percutaneous biliary drainage (PBD) has been the gold standard, but endoscopic ultrasound guided rendezvous (EUSr) have been increasingly used for biliary decompression in this patient population. Our aim was to compare the initial success rate, long-term efficacy, and safety of PBD and EUSr in relieving MDBO after failed ERC Patients and methods: A retrospective study involving 50 consecutive patients who had an initial failed ERCP for MDBO. Twenty-five patients undergoing EUSr between 2008 - 2014 were compared to 25 patients who underwent PBD immediately prior to the introduction of EUSr at our center (2002 - 2008). Comparisons were made between the two groups with regard to technical success, duration of hospital stay and adverse event rates after biliary decompression. The mean age at presentation was 66.5 (± 12.6 years), 28 patients (54.9 %) were female. The etiology of MDBO was pancreaticobiliary malignancy in 44 (88 %) and metastatic disease in 6 (12 %) cases. Biliary drainage was technically successful by EUSr in 19 (76 %) cases and by PBD in 25 (100 %) (P = 0.002). Median length of hospital stay after initial drainage was 1 day in the EUSr group vs 5 days in PBD group (P = 0.02). Repeat biliary intervention was required for 4 patients in the EUSr group and 15 in the PBD group (P = 0.001). Initial technical success with EUSr was significantly lower than with PBD, however when EUSr was successful, patients had a significantly shorter post-procedure hospital stay and required fewer follow-up biliary interventions. Meeting presentations: Annual Digestive Diseases Week 2015.

  2. Endoscopic Ultrasound-Guided Biliary Drainage

    International Nuclear Information System (INIS)

    Artifon, Everson L.A.; Ferreira, Fla'vio C.; Sakai, Paulo

    2012-01-01

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  3. Endoscopic Ultrasound-Guided Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Artifon, Everson L.A.; Ferreira, Fla& #x27; vio C.; Sakai, Paulo [University of Saeo Paulo, Saeo Paulo (Brazil)

    2012-02-15

    To demonstrate a comprehensive review of published articles regarding endoscopic ultrasound (EUS)-guided biliary drainage. Review of studies regarding EUS-guided biliary drainage including case reports, case series and previous reviews. EUS-guided hepaticogastrostomy, coledochoduodenostomy and choledoantrostomy are advanced biliary and pancreatic endoscopy procedures, and together make up the echo-guided biliary drainage. Hepaticogastrostomy is indicated in cases of hilar obstruction, while the procedure of choice is the coledochoduodenostomy or choledochoantrostomy in distal lesions. Both procedures must be performed only after unsuccessful ERCPs. The indication of these procedures must be made under a multidisciplinary view while sharing information with the patient or legal guardian. Hepaticogastrostomy and coledochoduodenostomy or choledochoantrostomy are feasible when performed by endoscopists with expertise in biliopancreatic endoscopy. Advanced echo-endoscopy should currently be performed under a rigorous protocol in educational institutions.

  4. Transbronchial drainage using endobronchial ultrasonography with guide sheath for lung abscess

    Science.gov (United States)

    Yaguchi, Daizo; Ichikawa, Motoshi; Inoue, Noriko; Kobayashi, Daisuke; Shizu, Masato; Imai, Naoyuki

    2018-01-01

    Abstract Rationale: Lung abscess was previously treated surgically, but is now mainly treated with antibiotics and ideally with direct drainage, although postural drainage canalso be used. Patient concerns: A chest abnormal shadow was detected in an 82-year-old man and he was referred to our department in November 2017. On chest computed tomography (CT), a low-density mass shadow was present in the left S8 segment. Lung abscess and lung cancer were considered as differential diagnoses, and treatment with sulbactam sodium/ampicillin sodium (SBT/ABPC) was first initiated for lung abscess. The etiologic agent could not be identified by sputum examination, and the abscess shadow remained. Diagnoses: Lung abscess. Interventions: Endobronchial ultrasonography with a guide sheath (EBUS-GS)-guided bronchoscopy was performed on hospital day 21 to diagnose the lesion, identify the etiologic agent if the lesion was a lung abscess, and attempt drainage. Vacuum aspiration performed in the guide sheath after the probe was placed within the lesion produced 4-5 ml of gray turbid pus, and the abscess was judged to have been drained. Outcomes: A subsequent pathological examination did not detect malignant cells. Klebsiella pneumoniae, Prevotella spp. was identified as the etiologic agent in bacteriological tests. Antibiotics were changed based on sensitivity test results, and drainage was similarly performed on hospital day 28. The shadow gradually improved and disappeared. Therefore, this procedure and treatment led to identification of the etiologic agent and helped with cure of the disease. Lessons: Based on the basic principle of treatment for abscess using as much drainage as possible, EBUS-GS-guided transbronchial drainage may be considered to be a “new procedure” for lung abscess. PMID:29768382

  5. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  6. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  7. Prospective evaluation of the radiologist's hand dose in CT-guided interventions

    International Nuclear Information System (INIS)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J.; Kropf, S.; Nekolla, E.A.; Wieners, G.

    2013-01-01

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  8. Short-term outcomes and safety of computed tomography-guided percutaneous microwave ablation of solitary adrenal metastasis from lung cancer: A multi-center retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Men, Min; Ye, Xin; Yang, Xia; Zheng, Aimin; Huang, Guang Hui; Wei, Zhigang [Dept. of Oncology, Shandong Provincial Hospital Affiliated with Shandong University, Jinan (China); Fan, Wei Jun [Imaging and Interventional Center, Sun Yat-sen University Cancer Center, Guangzhou (China); Zhang, Kaixian [Dept. of Oncology, Teng Zhou Central People' s Hospital Affiliated with Jining Medical College, Tengzhou (China); Bi, Jing Wang [Dept. of Oncology, Jinan Military General Hospital of Chinese People' s Liberation Army, Jinan (China)

    2016-11-15

    To retrospectively evaluate the short-term outcomes and safety of computed tomography (CT)-guided percutaneous microwave ablation (MWA) of solitary adrenal metastasis from lung cancer. From May 2010 to April 2014, 31 patients with unilateral adrenal metastasis from lung cancer who were treated with CT-guided percutaneous MWA were enrolled. This study was conducted with approval from local Institutional Review Board. Clinical outcomes and complications of MWA were assessed. Their tumors ranged from 1.5 to 5.4 cm in diameter. After a median follow-up period of 11.1 months, primary efficacy rate was 90.3% (28/31). Local tumor progression was detected in 7 (22.6%) of 31 cases. Their median overall survival time was 12 months. The 1-year overall survival rate was 44.3%. Median local tumor progression-free survival time was 9 months. Local tumor progression-free survival rate was 77.4%. Of 36 MWA sessions, two (5.6%) had major complications (hypertensive crisis). CT-guided percutaneous MWA may be fairly safe and effective for treating solitary adrenal metastasis from lung cancer.

  9. Fluoroscopy-Guided Percutaneous Gallstone Removal Using a 12-Fr Sheath in High-Risk Surgical Patients with Acute Cholecystitis

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Kim, Yong Joo; Shin, Tae Beom

    2011-01-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic cholecystolithotomy under fluoroscopic guidance in high-risk surgical patients with acute cholecystitis. Sixty-three consecutive patients of high surgical risk with acute calculous cholecystitis underwent percutaneous transhepatic gallstone removal under conscious sedation. The stones were extracted through the 12-Fr sheath using a Wittich nitinol stone basket under fluoroscopic guidance on three days after performing a percutaneous cholecystostomy. Large or hard stones were fragmented using either the snare guide wire technique or the metallic cannula technique. Gallstones were successfully removed from 59 of the 63 patients (94%). Reasons for stone removal failure included the inability to grasp a large stone in two patients, and the loss of tract during the procedure in two patients with a contracted gallbladder. The mean hospitalization duration was 7.3 days for acute cholecystitis patients and 9.4 days for gallbladder empyema patients. Bile peritonitis requiring percutaneous drainage developed in two patients. No symptomatic recurrence occurred during follow-up (mean, 608.3 days). Fluoroscopy-guided percutaneous gallstone removal using a 12-Fr sheath is technically feasible and clinically effective in high-risk surgical patients with acute cholecystitis

  10. Fluoroscopy-Guided Percutaneous Gallstone Removal Using a 12-Fr Sheath in High-Risk Surgical Patients with Acute Cholecystitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan [Keimyung University, College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of); Shin, Tae Beom [Gyeonsang National University, College of Medicine, Jinju (Korea, Republic of)

    2011-04-15

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic cholecystolithotomy under fluoroscopic guidance in high-risk surgical patients with acute cholecystitis. Sixty-three consecutive patients of high surgical risk with acute calculous cholecystitis underwent percutaneous transhepatic gallstone removal under conscious sedation. The stones were extracted through the 12-Fr sheath using a Wittich nitinol stone basket under fluoroscopic guidance on three days after performing a percutaneous cholecystostomy. Large or hard stones were fragmented using either the snare guide wire technique or the metallic cannula technique. Gallstones were successfully removed from 59 of the 63 patients (94%). Reasons for stone removal failure included the inability to grasp a large stone in two patients, and the loss of tract during the procedure in two patients with a contracted gallbladder. The mean hospitalization duration was 7.3 days for acute cholecystitis patients and 9.4 days for gallbladder empyema patients. Bile peritonitis requiring percutaneous drainage developed in two patients. No symptomatic recurrence occurred during follow-up (mean, 608.3 days). Fluoroscopy-guided percutaneous gallstone removal using a 12-Fr sheath is technically feasible and clinically effective in high-risk surgical patients with acute cholecystitis

  11. Influence able and Avoidable Risk Factors for Systemic Air Embolism due to Percutaneous CT-Guided Lung Biopsy: Patient Positioning and Coaxial Biopsy Technique-Case Report, Systematic Literature Review, and a Technical Note

    International Nuclear Information System (INIS)

    Rott, G.; Boecker, F.

    2014-01-01

    Following the first case of a systemic air embolism due to percutaneous CT-guided lung biopsy in our clinic we analysed the literature regarding this matter in view of influence able or avoidable risk factors. A systematic review of literature reporting cases of systemic air embolism due to CT-guided lung biopsy was performed to find out whether prone positioning might be a risk factor regarding this issue. In addition, a technical note concerning coaxial biopsy practice is presented. Prone position seems to have relevance for the development and/or clinical manifestation of air embolism due to CT-guided lung biopsy and should be considered a risk factor, at least as far as lesions in the lower parts of the lung are concerned. Biopsies of small or cavitary lesions in coaxial technique should be performed using a hemo static valve.

  12. Computed tomography- and fluoroscopy-guided percutaneous screw fixation of low-grade isthmic spondylolisthesis in adults: a new technique

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Huwart, Laurent; Browaeys, Patrick; Nouri, Yasir; Ibba, Caroline; Hauger, Olivier; Marcy, Pierre-Yves; Boileau, Pascal

    2012-01-01

    To evaluate the feasibility of computed tomography (CT)- and fluoroscopy-guided percutaneous screw fixation for the treatment of low-grade isthmic spondylolisthesis in adults. Ten consecutive adult patients (four men and six women; mean age: 57.1 [range, 44-78 years]) were prospectively treated by percutaneous screw fixation for low-grade (six grade 1 and four grade 2) isthmic spondylolisthesis of L5. For each patient, two 4.0-mm Asnis III cannulated screws were placed to fix the pars interarticularis defects. All procedures were performed under local anaesthesia by using CT and fluoroscopy guidance. Post-operative outcome was assessed using the visual analogue scale and Oswestry Disability Index (ODI) scores. The procedure time ranged from 45 to 60 min. The mean screw length was 27 mm (range, 24-32 mm). The VAS and ODI measurements ± SD decreased from 7.8 ± 0.9 preoperatively to 1.5 ± 1.1 at the last 2-year follow-up, and from 62.3 ± 17.2 to 15.1 ± 6.0, respectively (P < 0.001 in both cases). Neither slip progression nor screw failure was noted. This feasibility study showed that CT- and fluoroscopy-guided percutaneous screw fixation could be a rapid, safe and effective method of treating low-grade isthmic spondylolisthesis. (orig.)

  13. Computed tomography- and fluoroscopy-guided percutaneous screw fixation of low-grade isthmic spondylolisthesis in adults: a new technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Huwart, Laurent; Browaeys, Patrick; Nouri, Yasir; Ibba, Caroline [Hopital Archet 2, Centre Hospitalo-Universitaire de Nice, Department of Radiology, Nice (France); Hauger, Olivier [Hopital Pellegrin, Centre Hospitalo-Universitaire de Bordeaux, Department of Radiology, Bordeaux (France); Marcy, Pierre-Yves [Antoine Lacassagne Cancer Research Institute, Department of Radiology, Nice (France); Boileau, Pascal [Hopital Archet 2, Centre Hospitalo-Universitaire de Nice, Department of Orthopedic Surgery, Nice (France)

    2012-12-15

    To evaluate the feasibility of computed tomography (CT)- and fluoroscopy-guided percutaneous screw fixation for the treatment of low-grade isthmic spondylolisthesis in adults. Ten consecutive adult patients (four men and six women; mean age: 57.1 [range, 44-78 years]) were prospectively treated by percutaneous screw fixation for low-grade (six grade 1 and four grade 2) isthmic spondylolisthesis of L5. For each patient, two 4.0-mm Asnis III cannulated screws were placed to fix the pars interarticularis defects. All procedures were performed under local anaesthesia by using CT and fluoroscopy guidance. Post-operative outcome was assessed using the visual analogue scale and Oswestry Disability Index (ODI) scores. The procedure time ranged from 45 to 60 min. The mean screw length was 27 mm (range, 24-32 mm). The VAS and ODI measurements {+-} SD decreased from 7.8 {+-} 0.9 preoperatively to 1.5 {+-} 1.1 at the last 2-year follow-up, and from 62.3 {+-} 17.2 to 15.1 {+-} 6.0, respectively (P < 0.001 in both cases). Neither slip progression nor screw failure was noted. This feasibility study showed that CT- and fluoroscopy-guided percutaneous screw fixation could be a rapid, safe and effective method of treating low-grade isthmic spondylolisthesis. (orig.)

  14. Imaging-Guided Percutaneous Radiofrequency Ablation of Adrenal Metastases: Preliminary Results at a Single Institution with a Single Device

    International Nuclear Information System (INIS)

    Carrafiello, G.; Lagana, D.; Recaldini, C.; Giorgianni, A.; Ianniello, A.; Lumia, D.; D'Ambrosio, A.; Petulla, M.; Dionigi, G.; Fugazzola, C.

    2008-01-01

    The aim of this study was to show the feasibility, safety, imaging appearance, and short-term efficacy of image-guided percutaneous radiofrequency ablation (RFA) of adrenal metastases (AM). Seven imaging-guided percutaneous RFA treatments were performed in six patients (two men and four women; mean age, 67.2 years; range, 55-74 years) with six AM who were referred to our institution from 2003 to 2006. One patient was treated twice for recurrence after first treatment. The average diameter of the treated AM was 29 mm (range, 15-40 mm). In all patients, the diagnosis was obtained with CT current protocols in use at our institution and confirmed by pathology with an image-guided biopsy. No major complications occurred. In one patient shortly after initiation of the procedure, severe hypertension was noted; another patient developed post-RFA syndrome. In five of six lesions, there was no residual enhancement of the treated tumor. In one patient CT examination showed areas of residual enhancement of the tumor after treatment. Our preliminary results suggest that imaging-guided percutaneous RFA is effective for local control of AM, without major complications and with a low morbidity rate related to the procedure. Long-term follow-up will need to be performed and appropriate patient selection criteria will need to be determined in future randomized trials.

  15. Pancreatic duct drainage using EUS-guided rendezvous technique for stenotic pancreaticojejunostomy.

    Science.gov (United States)

    Takikawa, Tetsuya; Kanno, Atsushi; Masamune, Atsushi; Hamada, Shin; Nakano, Eriko; Miura, Shin; Ariga, Hiroyuki; Unno, Jun; Kume, Kiyoshi; Kikuta, Kazuhiro; Hirota, Morihisa; Yoshida, Hiroshi; Katayose, Yu; Unno, Michiaki; Shimosegawa, Tooru

    2013-08-21

    The patient was a 30-year-old female who had undergone excision of the extrahepatic bile duct and Roux-en-Y hepaticojejunostomy for congenital biliary dilatation at the age of 7. Thereafter, she suffered from recurrent acute pancreatitis due to pancreaticobiliary maljunction and received subtotal stomach-preserving pancreaticoduodenectomy. She developed a pancreatic fistula and an intra-abdominal abscess after the operation. These complications were improved by percutaneous abscess drainage and antibiotic therapy. However, upper abdominal discomfort and the elevation of serum pancreatic enzymes persisted due to stenosis from the pancreaticojejunostomy. Because we could not accomplish dilation of the stenosis by endoscopic retrograde cholangiopancreatography, we tried an endoscopic ultrasonography (EUS) guided rendezvous technique for pancreatic duct drainage. After transgastric puncture of the pancreatic duct using an EUS-fine needle aspiration needle, the guidewire was inserted into the pancreatic duct and finally reached to the jejunum through the stenotic anastomosis. We changed the echoendoscope to an oblique-viewing endoscope, then grasped the guidewire and withdrew it through the scope. The stenosis of the pancreaticojejunostomy was dilated up to 4 mm, and a pancreatic stent was put in place. Though the pancreatic stent was removed after three months, the patient remained symptom-free. Pancreatic duct drainage using an EUS-guided rendezvous technique was useful for the treatment of a stenotic pancreaticojejunostomy after pancreaticoduodenectomy.

  16. Temperature Measurements of the Low-Attenuation Radiographic Ice Ball During CT-Guided Renal Cryoablation

    International Nuclear Information System (INIS)

    Permpongkosol, Sompol; Link, Richard E.; Kavoussi, Louis R.; Solomon, Stephen B.

    2008-01-01

    During renal cryoablation a low-attenuation area on CT develops around the cryoprobe. Knowledge of the temperature of the growing low-attenuation area can guide therapy and ensure lethal temperatures. Herein, we report thermocouple results and correlating CT images during the development of the low-attenuation 'radiographic ice ball.' Five patients who underwent percutaneous CT-guided renal cryoablation were identified who had thermocouples inserted and serial intraprocedural CT images that included images with thermocouple measurements of 0 o and sub-0 o C. Thermocouples had been percutaneously placed just beyond the edge of the tumors either to ensure adequate cooling or to ensure safety to adjacent critical structures. Renal cryotherapy under CT guidance produced a growing low-attenuation area corresponding to the radiographic ice ball. When the thermocouple measured 0 o C, CT images showed the thermocouple tip at the edge of the low-attenuation ice ball. At lower temperatures the tip was within the low-attenuation ice ball. We conclude that knowledge of the temperature at the ice ball edge during cryoablation can be used to predict the extent of tissue necrosis and thus provide an estimate of cryotherapy effectiveness during the procedure. Further work is necessary to establish a firm relationship between the thermal conditions and the zone of damage

  17. Endoscopic ultrasound-guided pancreatic fluid collections' transmural drainage outcomes in 100 consecutive cases of pseudocysts and walled off necrosis: a single-centre experience from the United Kingdom.

    Science.gov (United States)

    Shekhar, Chander; Maher, Ben; Forde, Colm; Mahon, Brinder Singh

    2017-11-09

    Endoscopic ultrasound-guided drainage is a minimally invasive first-line modality for the drainage of pancreatic fluid collection (PFC) resulting in a shorter hospital stay and less morbidity compared with surgical cystogastrostomy. Our aim is to evaluate potential differences in the outcomes of endoscopic ultrasound (EUS) guided transmural drainage (EUS-TD) drainage of pancreatic pseudocyst (PP) and walled-off necrosis (WON). We retrospectively reviewed 100 consecutive EUS-guided drainages of PFC utilising EUS reports; clinical notes and imaging with follow-up (FU) to 12 months. All procedures were undertaken under conscious sedation with EUS guidance alone (without fluoroscopy) and placement of plastic double pigtail stents. In these 100 sequential cases, there were 78 cases of PP and 22 cases of WON. All 22/22(100%) cases of WON had successful EUS-guided stent placement. In 2/22(9%), there was little or no clinical improvement. These two patients required further computed tomography (CT)-guided drainage and one of these patients (1/22) (4.5%) developed recurrence within 12 months FU after removal of stents. In case of PP, overall stent placement was successful in 76/78 (97%) patients, but 6/78(8%) required 2nd EUS procedure after failure to show clinical improvement; 3/78(2.5%) required further CT-guided drainage. The overall complication rate was 9%(9/100) with 4%(4/100) requiring endoscopic or CT-guided intervention with no overall 30-day mortality. This is the largest series from a single UK centre demonstrating that EUS-guided cystogastrostomy of PFC drainage using plastic double pigtail stents is sufficient in majority of cases with PFC including that of WON, with or without infection.

  18. Percutaneous Drainage of 300 Intraperitoneal Abscesses with Long-Term Follow-Up

    International Nuclear Information System (INIS)

    Akinci, Devrim; Akhan, Okan; Ozmen, Mustafa N.; Karabulut, Nevzat; Ozkan, Orhan; Cil, Barbaros E.; Karcaaltincaba, Musturay

    2005-01-01

    The purpose of the study was to evaluate the efficacy of percutaneous drainage of intraperitoneal abscesses with attention to recurrence and failure rates. A retrospective analysis of percutaneous treatment of 300 intraperitoneal abscesses in 255 patients (147 male, 108 female; average age: 38 years; range: 40 days to 90 years) for whom at least 1-year follow-up data were available was performed. Abscesses were drained with fluoroscopic, sonographic, or computed tomographic guidance. Nine abscesses were drained by simple aspiration; catheter drainage either by Seldinger or trocar technique was used in the remaining 291 abscesses with 6F to 14 F catheters. Initial cure and failure rates were 68% (203/300) and 12% (36/300), respectively. Sixty-one abscesses (20%) were either palliated or temporized. The recurrence rate was 4% (12/300) and nine of them were cured by recatheterization, whereas three of them were treated by medication or surgery. The overall success and failure rates were 91% (273/300) and 9% (27/300), respectively, with temporized, palliated, and recatheterized recurred abscesses. The 30-day mortality rate was 3.1% (8/255). The mean duration of catheterization was 13 days. Intraperitoneal abscesses with safe access routes should be drained percutaneously because of high success and low morbidity, mortality, and recurrence rates

  19. Percutaneous management of bile duct injury after laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Islim, F.; Ors, S.; Salik, A.; Guven, K.; Yanar, F.; Alis, H.

    2012-01-01

    Full text: Introduction: The risk of bile duct injury after laparoscopic cholecystectomy is higher than open cholecystectomy. Objective: To discuss the importance of minimally invasive treatment options in the management of bile duct injuries after laparoscopic cholecystectomy and to present our approach in the management. Materials and methods: Management of 25 patients with symptomatic bile duct injury after laparoscopic cholecystectomy was retrospectively evaluated. Percutaneous collection drainage, endoscopic retrograde cholangiopancreatography (ERCP), percutaneous transhepatic cholangiography (PTC) and percutaneous biliary drainage were performed for the management of the patients. Results: Mean age of the patients (15 women, 10 men) was 55. Either ultrasonography or computed tomography guided percutaneous drainage was performed in 13 patients. 9 of them completely recovered only with percutaneous drainage. In 4 of them ERCP was performed because of high drainage volume. In 9 of the patients with jaundice and high bilirubin levels ERCP was performed as the first option. And 3 patients were reoperated because of acute abdomen signs. ERCP, MRCP and PTC revealed type A in 7, type E2 in 3, type E3 in 3 and type E4 in 1 of the patients according to Strasberg classification. Conclusion: Presenting symptoms of the patients with symptomatic bile duct injury are useful in the determination of the treatment option.

  20. Presumed appendiceal abscess discovered to be ruptured Meckel diverticulum following percutaneous drainage

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jeannie C.; Ostlie, Daniel J. [Children' s Mercy Hospital, Department of Surgery, Kansas City, MO (United States); Rivard, Douglas C.; Morello, Frank P. [Children' s Mercy Hospital, Department of Radiology, Kansas City, MO (United States)

    2008-08-15

    A Meckel diverticulum is an embryonic remnant of the omphalomesenteric duct that occurs in approximately 2% of the population. Most are asymptomatic; however, they are vulnerable to inflammation with subsequent consequences including diverticulitis and perforation. We report an 11-year-old boy who underwent laparoscopic appendectomy for perforated appendicitis at an outside institution. During his convalescence he underwent percutaneous drainage of a presumed postoperative abscess. A follow-up drain study demonstrated an enteric fistula. The drain was slowly removed from the abdomen over a period of 1 week. Three weeks following drain removal the patient reported recurrent nausea and abdominal pain. A CT scan demonstrated a 3.7-cm rim-enhancing air-fluid level with dependent contrast consistent with persistent enteric fistula and abscess. Exploratory laparoscopy was performed, at which time a Meckel diverticulum was identified and resected. This case highlights the diagnostic challenge and limitations of conventional radiology in complicated Meckel diverticulum. (orig.)

  1. CT-guided interventions in children; Computertomografisch gesteuerte Interventionen bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2007-06-15

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  2. Retrospective analysis of technical success rate and procedure-related complications of 867 percutaneous CT-guided needle biopsies of lung lesions.

    Science.gov (United States)

    Mills, M; Choi, J; El-Haddad, G; Sweeney, J; Biebel, B; Robinson, L; Antonia, S; Kumar, A; Kis, B

    2017-12-01

    To investigate the technical success rate and procedure-related complications of computed tomography (CT)-guided needle biopsy of lung lesions and to identify the factors that are correlated with the occurrence of procedure-related complications. This was a single- institution retrospective study of 867 consecutive CT-guided needle biopsies of lung lesions performed on 772 patients in a tertiary cancer centre. The technical success rate and complications were correlated with patient, lung lesion, and procedure-related variables. The technical success rate was 87.2% and the mortality rate was 0.12%. Of the 867 total biopsies 25.7% were associated with pneumothorax, and 6.5% required chest tube drainage. The haemothorax rate was 1.8%. There was positive correlation between the development of pneumothorax and smaller lesion diameter (ptechnical success and a low rate of major complications. The present study has revealed several variables that can be used to identify high-risk procedures. A post-procedural chest X-ray within hours after the procedure is highly recommended to identify high-risk patients who require chest tube placement. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  3. CT-guided percutaneous laser disc decompression with Ceralas D, a diode laser with 980-nm wavelength and 200-μm fiber optics

    International Nuclear Information System (INIS)

    Gevargez, A.; Groenemeyer, D.W.H.; Czerwinski, F.

    2000-01-01

    The aim of this study was to evaluate the compact, portable Ceralas-D diode laser (CeramOptec; 980+30 nm wavelength, 200-μm optical fiber) concerning clinical usefulness, handling, and clinical results in the CT-guided treatment of herniated lumbar discs. The positioning of the canula in intradiscal space, the placement of the laser fiber into the disc through the lying canula, and the vaporization itself were carried out under CT-guidance. Due to the thin fiber optic, it was possible to use a thin 23-gauge canula. The laser procedure was performed in 0.1- to 1-s shots with 1-s pulse pause and 4-W power output. A total of 1650-2300 J was applied on each percutaneous laser disc decompression (PLDD). Results in 26 patients were established with a visual-analogue scale (VAS). On the follow-up examinations, 46% of the patients were absolutely pain free (>85% VAS) and fully active in everyday life after 4 postoperative weeks. Thirty-one percent of patients were relieved of the leg pain but had occasional back pain without sensorimotor impairment. Fifteen percent sensed a slight alleviation (>50% VAS) of the radiate pain. Eight percent did not experience radicular or pseudo-radicular pain alleviation (<25% VAS). Cerales-D proves to be an efficient tool for CT-guided PLDD on non-sequestered herniated lumbar discs. (orig.)

  4. Percutaneous transhepatic drainage of lung abscess through a diaphragmatic fistula caused by a penetrating liver abscess.

    Science.gov (United States)

    Taniguchi, Masako; Morita, Satoru; Ueno, Eiko; Hayashi, Mitsutoshi; Ishikawa, Motonao; Mae, Masahiro

    2011-11-01

    Liver abscesses occurring just below the diaphragm can penetrate or perforate the thoracic cavity, resulting in lung abscess or pyothorax. Although surgical or percutaneous transpleural drainage is often required in such cases, the latter approach has some risks, including hemothorax and bronchopleural fistula formation when the cavity is surrounded by normal lung parenchyma. The present report describes a treatment technique of percutaneous transhepatic drainage through the diaphragmatic fistula to avoid the risks of a transpulmonary approach in a case of lung abscess caused by a penetrating liver abscess.

  5. Fluoroscopy-Guided Percutaneous Lung Biopsy: A Valuable Alternative to Computed Tomography

    International Nuclear Information System (INIS)

    Kurban, L.A.; Gomersall, L.; Weir, J.; Wade, P.

    2008-01-01

    Background: Computed tomography (CT) fluoroscopy nowadays is the most preferred method of guidance to perform percutaneous lung biopsy of pulmonary masses. Conventional fluoroscopy is an increasingly forgotten technique that still can be used to perform lung biopsies, with many advantages. Purpose: To compare the accuracy, safety, and effective dose (ED) of conventional fluoroscopy-guided needle lung biopsy (FNLB) with CT-guided needle lung biopsy procedures (CTNLB) reported in the literature. Material and Methods: 100 consecutive patients who underwent FNLB were reviewed retrospectively. Using the final histological diagnoses and the clinical and radiological course of the disease as references, the accuracy and sensitivity of FNLB were calculated. The complication rates of FNLB were assessed. Using computer software (XDOSE), the ED was calculated. The accuracy, complication rates, and the ED of FNLB were compared with CTNLB reported in the literature. Results: The overall accuracy rate and sensitivity of FNLB were both 87%, which are comparable to the range of accuracies reported in the literature for CTNLB (74-97%). The complication rates of FNLB were also comparable to the complication rates reported for CTNLB. The commonest complication was pneumothorax, at a rate of 25%. The ED of FNLB was small, significantly lower than reported in the literature for CT-guided procedures. The mean ED of FNLB was 0.029 mSv, which is approximately equivalent to one chest X-ray. Conclusion: Conventional fluoroscopy is an accurate, safe, and low-dose alternative modality to CT to obtain an image-guided histological diagnosis of pulmonary lesions

  6. Multiple pyogenic liver abscesses formed after appendectomy: The role of percutaneous drainage in a critically ill patient

    Directory of Open Access Journals (Sweden)

    Enver Zerem

    2012-11-01

    Full Text Available Multiple pyogenic liver abscesses formed after appendectomy andtheir percutaneous treatment with multiple catheters have been rarelydescribed. We report a case of multiple pyogenic liver abscesses in acritically ill patient, formed after appendectomy and treated successfully by antibiotics and drainage with six catheters that were introduced simultaneously under ultrasound control. Even though this was a case of liver abscess secondary to appendicitis, today very rare in Western countries, but still a serious complication in developing countries, it was successfully resolved by percutaneous drainage, along with antibiotic therapy. Conclusion. We emphasize the advantages of percutaneous treatment compared with surgery regarding the avoidance of perioperative complications and the risks of general anesthesia.

  7. CT-guided thin needles percutaneous cryoablation (PCA) in patients with primary and secondary lung tumors: A preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio, E-mail: clapusceddu@gmail.com [Division of Interventional Radiology, Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncologic Diseases, Cagliari, Zip code 09100 (Italy); Sotgia, Barbara, E-mail: barbara.sotgia@gmail.com [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Fele, Rosa Maria, E-mail: rosellafele@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy); Melis, Luca, E-mail: doclucamelis@tiscali.it [Department of Oncological Radiology, Businco Hospital, Regional Referral Center for Oncological Diseases, Cagliari, Zip code 09100 (Italy)

    2013-05-15

    Purpose: To report the data of our initial experience with CT-guided thin cryoprobes for percutaneous cryoablation (PCA) in patients with primary and secondary pulmonary tumors. Material and methods: CT-guided thin needles PCA was performed on 34 lung masses (11 NSCLC = 32%; 23 secondary lung malignancies = 68%) in 32 consecutive patients (24 men and 8 women; mean age 67 ± 10 years) not suitable for surgical resection. Lung masses were treated using two types of cryoprobes: IceRod and IceSeed able to obtain different size of iceball. The number of probes used ranged from 1 to 5 depending on the size of the tumor. After insertion of the cryoprobes into the lesion, the PCA were performed with two 2 (91%) or 3 (9%) cycles each of 12 min of freezing followed by a 4 min active thawing phase and a 4 min passive thawing phase for each one for all treatments. Results: All cryoablation sessions were successfully completed. All primary and metastatic lung tumors were ablated. No procedure-related deaths occurred. Morbidity consisted of 21% (7 of 34) pneumothorax and 3% (1 of 34) cases asymptomatic small pulmonary hemorrhage, respectively, all of CTCAE grade 1 (Common Terminology Criteria for Adverse Events). Low density of entire lesion, central necrosis and solid mass appearance were identify in 21 (62%), 7 (21%) and 6 (17%) of cryoablated tumors, respectively. No lymphadenopathy developed in the region of treated lesions. Technical success (complete lack of enhancement) was achieved in 82%, 97% and 91% of treated lesions at 1-, 3- and 6-months CT follow-up scan, respectively (p < .000). Comparing the tumor longest diameter between the baseline and at 6 month CT images, technical success was revealed in 92% cases (p < .000). Conclusion: Our preliminary experience suggests that PCA is a feasible treatment option. Well-designed clinical trials with a larger patient population are necessary to further investigate the long-term results and prognostic factors.

  8. Contribution of computed tomography on chest drainage guidance

    International Nuclear Information System (INIS)

    Douvlou, E.; Tzortzis, D.; Vlachou, I.; Petrocheilou, G.; Safarika, V.; Fragopoulou, L.; Stathopoulou, S.; Kokkinis, C.

    2012-01-01

    Full text: Introduction: Thoracic collections (encysted pleural, endopulmonary, mediastinal) are common findings in major trauma hospitals mainly in need of further treatment as drainage. Objectives and tasks: To evaluate the CT-guidance, as a method of choice for thoracic drainages. Material and methods: 35 CT-guided chest drainages were performed for diagnostic and therapeutic purpose in 33 patients, with a mean age of 62 years. Of the 35 drainages, 31 were encysted at the pleura, 3 of them were endopulmonary and 1 was in the mediastinum. During the procedure we used needles of 15cm long and 18-22 G diameter for small collections while for 'large' collections drainage catheters of 10-16 F were placed. Results: All the CT-guided drainages of the chest were successful. Of them, 7 were pleural effusion collections while 24 were exudate collections (18 inflammatory and 6 neoplastic) and all were developed in the lungs or the mediastinum. In all the cases that a catheter was placed, full removal of the collections was achieved leading to a remarkable improvement of the patient's condition. Non-significant pneumothorax and tiny endopulmonary bleeding were the complications that occurred. Conclusion: CT-guided drainage of thoracic collections is an accurate and secure procedure and achieves high diagnostic and therapeutic results

  9. Understanding the Lung Abscess Microbiome: Outcomes of Percutaneous Lung Parenchymal Abscess Drainage with Microbiologic Correlation

    International Nuclear Information System (INIS)

    Duncan, Christopher; Nadolski, Gregory J.; Gade, Terence; Hunt, Stephen

    2017-01-01

    IntroductionLung parenchymal abscesses represent an uncommon pathology with high mortality if untreated. Although most respond well to antibiotics, the optimal therapy for persistent abscesses is unknown. The purpose of this study was to review the outcomes of percutaneous lung parenchymal abscess catheter drainage after broad-spectrum antibiotic therapy failure and correlate with patient microbiologic samples.Materials and MethodsRetrospective review of patients who underwent percutaneous lung abscess drainage at a tertiary hospital system from 2005 to 2015 was performed. In total, 19 procedures were identified on 16 different patients; six females and ten males. Mean patient age was 55 years (range 22–81). Median follow-up time was 7 months (range <1–78).ResultsTechnical success was 100%. There was one major complication, a pneumothorax. Follow-up was until tube removal or death in 100% of patients. Catheters were removed with resolution of the abscess cavity in 58% (11/19) or with non-draining abscess cavities in 21% (4/19) for a clinical success rate of 79%. Blood cultures demonstrated no growth in all cases, while 21% (4/19) of sputum or bronchoscopic cultures demonstrated growth. In comparison, the specimens from initial catheter placement isolated a causative organism in 95% (18/19) of case (p < 0.0001).ConclusionIn cases of persistent lung abscess after broad-spectrum antibiotics, percutaneous abscess drainage is highly sensitive for microbiologic sampling compared to sputum/bronchoscopic or blood cultures. Additionally, percutaneous drainage of lung parenchymal abscess cavities may promote resolution of the abscess with high rates of therapeutic success and low complications.

  10. Understanding the Lung Abscess Microbiome: Outcomes of Percutaneous Lung Parenchymal Abscess Drainage with Microbiologic Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, Christopher; Nadolski, Gregory J.; Gade, Terence; Hunt, Stephen, E-mail: Stephen.hunt@uphs.upenn.edu [Hospital of the University of Pennsylvania, Perelman School of Medicine, Division of Interventional Radiology, Department of Radiology (United States)

    2017-06-15

    IntroductionLung parenchymal abscesses represent an uncommon pathology with high mortality if untreated. Although most respond well to antibiotics, the optimal therapy for persistent abscesses is unknown. The purpose of this study was to review the outcomes of percutaneous lung parenchymal abscess catheter drainage after broad-spectrum antibiotic therapy failure and correlate with patient microbiologic samples.Materials and MethodsRetrospective review of patients who underwent percutaneous lung abscess drainage at a tertiary hospital system from 2005 to 2015 was performed. In total, 19 procedures were identified on 16 different patients; six females and ten males. Mean patient age was 55 years (range 22–81). Median follow-up time was 7 months (range <1–78).ResultsTechnical success was 100%. There was one major complication, a pneumothorax. Follow-up was until tube removal or death in 100% of patients. Catheters were removed with resolution of the abscess cavity in 58% (11/19) or with non-draining abscess cavities in 21% (4/19) for a clinical success rate of 79%. Blood cultures demonstrated no growth in all cases, while 21% (4/19) of sputum or bronchoscopic cultures demonstrated growth. In comparison, the specimens from initial catheter placement isolated a causative organism in 95% (18/19) of case (p < 0.0001).ConclusionIn cases of persistent lung abscess after broad-spectrum antibiotics, percutaneous abscess drainage is highly sensitive for microbiologic sampling compared to sputum/bronchoscopic or blood cultures. Additionally, percutaneous drainage of lung parenchymal abscess cavities may promote resolution of the abscess with high rates of therapeutic success and low complications.

  11. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    Science.gov (United States)

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  12. Percutaneous extraction of osteoid osteoma with CT guidance (20 cases)

    International Nuclear Information System (INIS)

    Joffre, P.; Poey, C.; Assoun, J.; Kohler, R.; Bonnevialle, P.; Giron, J.M.

    1991-01-01

    In this paper, the authors report 20 cases of percutaneous extraction of osteoid osteoma under CT guidance. Typical pain and findings of plain radiography, bone scintigraphy, and CT were suggestive of the lesion. They were located on the lower limb (n = 16), acetabulum (n = 3), and vertebra (n = 1). Percutaneous extraction is performed under general anesthesia in the CT room. The authors describe the procedure of nidus extraction. CT allowed total removal of the nidus. There are no residual paid 1-3 days after the procedure. findings of clinical and plain radiographic follow-up are satisfactory (3-18 months). Histologic confirmation was obtained in all cases. This new technique of osteoid osteoma extraction under CT guidance allows precise removal of the nidus with pathologic verification. The duration of hospitalization and the therapeutic cost are widely reduced

  13. Percutaneous transhepatic sclerotherapy with embolization of the drainage vein for a gastric varix

    OpenAIRE

    Yoshimatsu, Rika; Yamagami, Takuji; Miura, Hiroshi; Okuda, Kotaro

    2014-01-01

    We experienced a case with a gastric varix that did not have a catheterizable main drainage vein and had multiple afferent veins. For this case we successfully performed percutaneous transhepatic sclerotherapy using the following procedure. After the drainage vein was embolized by metallic coils and n-butyl cyanoacrylate from a microcatheter that was advanced through the gastric varix, 5% ethanolamine oleate-iopamidol was infused into the gastric varix from one main afferent vein under balloo...

  14. Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

    Energy Technology Data Exchange (ETDEWEB)

    Firouznia, Kavous, E-mail: k-firouznia@yahoo.com; Hosseininasab, Sayed jaber, E-mail: dr.hosseininasab@gmail.com [Tehran University of Medical Sciences (TMUS), Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Imam Khomeini Hospital Complex (Iran, Islamic Republic of); Amanpour, Saeid, E-mail: saeidamanpour@yahoo.com [Tehran University of Medical Science, Cancer Models Research Center, Cancer Institute of Iran (Iran, Islamic Republic of); Haj-Mirzaian, Arya, E-mail: arya.mirzaian@gmail.com [Tehran University of Medical Science, Department of Radiology and Imaging, MIC, Imam Khomeini Hospital (Iran, Islamic Republic of); Miri, Roza, E-mail: rosa.miri@yahoo.com [Tehran University of Medical Science, Department of Pathology, Imam Khomeini Hospital Complex (Iran, Islamic Republic of); Muhammadnejad, Ahad, E-mail: mohamadnejad@yahoo.com [Tehran University of Medical Science, Cancer Research Center, Cancer Institute of Iran (Iran, Islamic Republic of); Muhammadnejad, Samad, E-mail: s-muhammadnejad@sina.tums.ac.ir [Tehran University of Medical Sciences, Research Center for Molecular and Cellular Imaging (Iran, Islamic Republic of); Jalali, Amir H., E-mail: amirjalali51@yahoo.com [Tehran University of Medical Sciences (TMUS), Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Imam Khomeini Hospital Complex (Iran, Islamic Republic of); Ahmadi, Farrokhlagha, E-mail: ahmadi@tums.ac.ir [Tehran University of Medical Sciences, Nephrology Research Center, Imam Khomeini Hospital Complex (Iran, Islamic Republic of); Rokni-Yazdi, Hadi, E-mail: rokniyaz@tums.ac.ir [Tehran University of Medical Sciences (TMUS), Advanced Diagnostic and Interventional Radiology Research Center (ADIR), Imam Khomeini Hospital Complex (Iran, Islamic Republic of)

    2015-08-15

    BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MR imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension.

  15. Renal Sympathetic Denervation by CT-scan-Guided Periarterial Ethanol Injection in Sheep

    International Nuclear Information System (INIS)

    Firouznia, Kavous; Hosseininasab, Sayed jaber; Amanpour, Saeid; Haj-Mirzaian, Arya; Miri, Roza; Muhammadnejad, Ahad; Muhammadnejad, Samad; Jalali, Amir H.; Ahmadi, Farrokhlagha; Rokni-Yazdi, Hadi

    2015-01-01

    BackgroundRenal nerves are a recent target in the treatment of hypertension. Renal sympathetic denervation (RSD) is currently performed using catheter-based radiofrequency ablation (RFA) and because this method has limitations, percutaneous magnetic resonance (MR)-guided periarterial ethanol injection is a suggested alternative. However, few studies have been conducted on the effectiveness of percutaneous ethanol injection for RSD.AimTo evaluate the feasibility, efficacy, and complications of computed tomography (CT)-guided periarterial ethanol injection.MethodsEthanol (10 ml, 99.6 %) was injected around the right renal artery in six sheep under CT guidance with the left kidney serving as a control. Before and after the intervention, the sheep underwent MR imaging studies and the serum creatinine level was measured. One month after the intervention, the sheep were euthanized and norepinephrine (NE) concentration in the renal parenchyma was measured to evaluate the efficacy of the procedure. The treated tissues were also examined histopathologically to evaluate vascular, parenchymal, and neural injury.ResultsThe right kidney parenchymal NE concentration decreased significantly compared with the left kidney after intervention (average reduction: 40 %, P = 0.0016). Histologic examination revealed apparent denervation with no other vascular or parenchymal injuries observed in the histological and imaging studies.ConclusionEffective and feasible RSD was achieved using CT-guided periarterial ethanol injection. This technique may be a potential alternative to catheter-based RFA in the treatment of hypertension

  16. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Paek, Auh Whan [Dept. of Radiology, Virginia University Heath Center, Charlottesville (United States); Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of)

    2011-04-15

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  17. Usefulness of a Biliary Manipulation Catheter in Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Paek, Auh Whan; Won, Je Hwan; Lee, Jei Hee; Sun, Joo Sung; Kwak, Kyu Sung; Bae, Jae Ik

    2011-01-01

    To evaluate usefulness of a manipulation catheter in percutaneous transhepatic biliary drainage (PTBD). A biliary manipulation catheter was used for the aspiration of retained bile and lesion crossing during an initial PTBD in 91 consecutive patients over a 6 month period. This catheter allowed for a 0.035 inch guide wire made of 5F short steel braided polyurethane. The terminal 1 cm segment was tapered and 45 degree angulated. Two side holes were made in the terminal segment to facilitate the aspiration of bile. The safety of this procedure was evaluated based on whether the catheters caused complications during insertion and manipulation, and whether cholangitis was aggravated after the procedure. Effectiveness of the procedure was evaluated based on the ability to aspirate retained bile and to cross the lesion. Both the insertion of a 0.035 inch hydrophilic guide wire and aspiration of sufficient retained bile were successful with the catheter. Crossing the common bile duct (CBD) lesion had a 98.1% success rate during the initial PTBD. Crossing the hilar obstruction lesion was had a 94.7% success rate to the CBD and 92.1% to the contralateral lobe. Cholangitis improved in 97% of cases, and aggravated transiently in only 3% of cases after PTBD.

  18. Pancreatic cancer seeding of percutaneous needle tract

    Directory of Open Access Journals (Sweden)

    Qiao Zhou, MD

    2017-03-01

    Full Text Available A 65-year old African-American female presents with biliary ductal dilatation due to an obstructive pancreatic head mass. Percutaneous transhepatic cholangiogram performed and biliary drainage catheter placement for decompression of the biliary system. The patient had a Whipple procedure performed several months later. On follow up CT imaging, there was interval development and enlargement of a subcutaneous lesion by the right oblique muscles. Biopsy of this lesion revealed pancreatic adenocarcinoma from percutaneous seeding of the transhepatic needle tract.

  19. Preoperative Computed Tomography-Guided Percutaneous Hookwire Localization of Metallic Marker Clips in the Breast with a Radial Approach: Initial Experience

    Energy Technology Data Exchange (ETDEWEB)

    Uematsu, T.; Kasami, M.; Uchida, Y.; Sanuki, J.; Kimura, K.; Tanaka, K.; Takahashi, K. [Dept. of Diagnostic Radiology, Dept. of Pathology, and Dept. of Breast Surgery, Shizuoka Cancer Center Hospital, Naga-izumi, Shizuoka (Japan)

    2007-07-15

    Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  20. Preoperative computed tomography-guided percutaneous hookwire localization of metallic marker clips in the breast with a radial approach: initial experience.

    Science.gov (United States)

    Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K

    2007-06-01

    Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.

  1. Percutaneous drainage of Morel-Lavallée lesions when the diagnosis is delayed.

    Science.gov (United States)

    Zhong, Biao; Zhang, Chi; Luo, Cong-feng

    2014-10-01

    Morel-Lavallée lesions are a closed internal degloving, and open débridement can damage the only remaining blood supply to the skin. We performed percutaneous draining and débridement to treat 8 patients in whom the diagnosis of Morel-Lavallée lesions was delayed more than 1 week. Here we discuss our treatment procedures and the outcomes in these 8 patients. We consider percutaneous drainage to be an effective treatment for patients with delayed diagnosis of Morel-Lavallée lesions.

  2. Percutaneous biliary drainage in patients with cholangiocarcinoma

    International Nuclear Information System (INIS)

    Mehta, A.C.; Gobel, R.J.; Rose, S.C.; Hayes, J.K.; Miller, F.J.

    1990-01-01

    This paper determines whether radiation therapy (RT) is a risk factor for infectious complications (particularly hepatic abscess formation) related to percutaneous biliary drainage (PBD). The authors retrospectively reviewed the charts of 98 consecutive patients who had undergone PBD for obstruction. In 34 patients with benign obstruction, three infectious complications occurred, none of which were hepatic abscess or fatal sepsis. In 39 patients who had malignant obstruction but did not have cholangiocarcinoma, 13 infectious complications occurred, including two hepatic abscesses and three cases of fatal sepsis. Of the 25 patients with cholangiocarcinoma, 15 underwent RT; in these 15 patients, 14 infectious complications occurred, including six hepatic abscesses and two cases of fatal sepsis

  3. Transbronchial drainage using endobronchial ultrasonography with guide sheath for lung abscess: A case report.

    Science.gov (United States)

    Yaguchi, Daizo; Ichikawa, Motoshi; Inoue, Noriko; Kobayashi, Daisuke; Shizu, Masato; Imai, Naoyuki

    2018-05-01

    Lung abscess was previously treated surgically, but is now mainly treated with antibiotics and ideally with direct drainage, although postural drainage canalso be used. A chest abnormal shadow was detected in an 82-year-old man and he was referred to our department in November 2017. On chest computed tomography (CT), a low-density mass shadow was present in the left S8 segment. Lung abscess and lung cancer were considered as differential diagnoses, and treatment with sulbactam sodium/ampicillin sodium (SBT/ABPC) was first initiated for lung abscess. The etiologic agent could not be identified by sputum examination, and the abscess shadow remained. Lung abscess. Endobronchial ultrasonography with a guide sheath (EBUS-GS)-guided bronchoscopy was performed on hospital day 21 to diagnose the lesion, identify the etiologic agent if the lesion was a lung abscess, and attempt drainage. Vacuum aspiration performed in the guide sheath after the probe was placed within the lesion produced 4-5 ml of gray turbid pus, and the abscess was judged to have been drained. A subsequent pathological examination did not detect malignant cells. Klebsiella pneumoniae, Prevotella spp. was identified as the etiologic agent in bacteriological tests. Antibiotics were changed based on sensitivity test results, and drainage was similarly performed on hospital day 28. The shadow gradually improved and disappeared. Therefore, this procedure and treatment led to identification of the etiologic agent and helped with cure of the disease. Based on the basic principle of treatment for abscess using as much drainage as possible, EBUS-GS-guided transbronchial drainage may be considered to be a "new procedure" for lung abscess.

  4. Isolate pulmonary nodule. CT-guided biopsy

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Ettore, F.; Rogopoulos, A.; Geoffray, A.; Balu-Maestro, C.; Le Houcq, M.

    1989-01-01

    Transparietal CT-guided biopsy location can be successfully performed for isolate pulmonary nodules, defined as lesions with a maximal diameter of 3 cm, without any other parenchymal or mediastinal abnormality. A 21 G needle has been used according to an identical protocole in 64 cases (10 benign, 54 malignant). The biopsy was successful in 77.7% of the malignant cases. In relation to the diameter of the nodules, biopsy was successful in 66.7% of the nodules smaller than 2 cm and in 76% of the nodules ranging from 2 to 3 cm. The complications observed were rare (1 case of pneumothorax requiring drainage, 9 cases of pneumothorax without clinical signs and simply followed up, 4 cases of minor hemoptysis requiring no treatment and 5 cases of hematomas smaller than 5 cm on CT) [fr

  5. A new device of CT-targeted percutaneous punctures

    International Nuclear Information System (INIS)

    Ozdoba, C.

    1990-01-01

    This paper reports on a device for CT-targeted percutaneous punctures. After extensive phantom studies, punctures of vertebral disk space (diskography/nucleotomy) and orbit retrobulbar anesthesia/biopsy were performed in 15 patients. The new device is easy to mount on the CT scanner and does not require additional devices affixed to the patient. Its design and construction permit exact calculation of needle angle and depth, even when the gantry is tilted. Percutaneous biopsies can be performed in approximately 40 minutes. The device is accurate within ±0.5 mm, thereby allowing puncture of even small lesions deep in the orbital cone. Retrobulbar anesthesia can be performed safely in patients with a long myopic bulbus; in nucleotomy, instant control of the instrument's position within the disk space is possible

  6. Percutaneous intervention in obstructive

    International Nuclear Information System (INIS)

    Souftas, V.

    2012-01-01

    , performed by the urologist. Before performing a lithotripsy, percutaneous access of the renal collecting system is necessary. Percutaneous ureteral lithotripsy is indicated for management of large renal stones. The kidneys are accessed either using ultrasound, if there is a dilated collecting system, or fluoroscopy, if there is a radiopaque stone. The most ideal access is a calyx that bears the stone. Once access is obtained an angled glide wire is used to cross the obstructing stone and gain access to the ureter. Two wires can then be advanced to the bladder to provide a 'working wire' and a 'safety wire'. Success of lithotripsy is 98-99% for targeted renal stones and 88-89% for ureteral stones. If using only fluoroscopy, a sheathed needle may be used to access the bladder under fluoroscopy. Once urine is aspirated through the sheathed needle, a 3Jwire is inserted into the bladder under fluoroscopy. Using an angled guiding catheter, the 3J-wire is exchanged for an Amplatz and serial dilatation of the tract is performed over the Amplatz. Finally, an 8-F to 12-F suprapubic Foley catheter is inserted over the Amplatz wire into the bladder. Success rate for suprapubic tube insertion has been reported to approach 100% and is comparable to surgical insertion. Complications include bleeding, infection, and bladder or bowel perforation. Perinephric/retroperitoneal urinomas/abscesses drainages are usually due to ureteral obstruction/ trauma from calculi and rupture of the collecting system or to iatrogenic trauma. Most often they are performed under CT guidance, with success rates 100% and very low complication rates. Pigtail drainage catheters 8-F (up to 14-F for abscesses) are used. Sometimes these procedures have to be combined with percutaneous nephrostomy and percutaneous or antegrade ureteral stent placement.

  7. CT guided fine needle aspiration biopsy of biliopancreatic lesions

    International Nuclear Information System (INIS)

    Geng, Jia-Zheng; Qin, Pan-Rui; Hui, Liu-De; Po, Pei-Dong

    1987-01-01

    CT guided percutaneous fine needle aspiration biopsy was performed on 30 patients with pancreatic and periampullary neoplasms, in the Department of Surgery, China-Japan Friendship Hospital, between March 1985 and January 1986. We obtained positive cytodiagnosis from all cases of carcinoma of the pancreatic head (9 cases), body and tail (4 cases), and ampullary carcinomas (5 cases) (100 per cent). In 2 of 3 duodenal carcinomas (66.6 per cent), and 6 of 7 distal common duct carcinomas (86 per cent), a positive cytodiagnosis was also obtained. On the other hand, 2 cases of pancreatitis both gave a negative cytodiagnosis, i.e. no false positives were obtained. Out of the 30 cases who underwent CT guided biopsy, a correct diagnosis was obtained in 28, i.e. a diagnostic accuracy of 93.3 per cent. The cytodiagnosis of the other two cases was either suspicious or false negative. There have been no clinical complications noted. (author)

  8. CT findings complicating percutaneous nephrostomy, lithotomy and lithotripsy

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Susumu; Douke, Tetsuya; Araki, Toru; Takamoto, Hitoshi; Yoshida, Mitsuhiro; Hata, Kazuhiro (Center for Adult Diseases, Kurashiki, Okayama (Japan)); Yasui, Kotaro

    1990-09-01

    Reviews of the CT scans of percutaneous nephrostomy, lithotomy and lithotripsy disclosed 14 out of 78 cases (17.9%) with evidence of complications. Renal and perirenal hematomas were detected in five cases and the other five cases showed collections of contrast material in the retroperitoneum except for the anterior pararenal space. CT demonstrated clearly the anatomic distribution and extent of renal hemorrhage and extravasation of contrast material. Three cases of pleural effusion on CT were accompanied by blood or contrast material collections in the posterior pararenal space. No patients required immediate surgery and CT findings helped the choice of conservative therapies. (author).

  9. CT-guided percutaneous vertebroplasty combined with 125I-seed implantation for metastatic vertebral carcinoma involving the spinal canal: analysis of 23 cases

    International Nuclear Information System (INIS)

    Xie Xiaoxi; Lu Yinxiang; Ji Yong; Wang Xiaowei; Zhang Guodong

    2014-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous vertebroplasty (PVP) combined with 125 I-seed implantation for the treatment of metastatic vertebral carcinoma involving the spinal canal. Methods: A total of 28 involved vertebrae were detected in 23 patients with metastatic vertebral carcinoma. Each patient had 1-2 diseased vertebrae. The lesions included cervical vertebra (n=4), thoracic vertebra (n=13) and lumbar vertebra (n=11). Destroyed posterior vertebral wall was seen in all involved vertebrae. Thirteen vertebrae found in 12 patients showed involvement of the epidural space. According to treatment planning system (TPS) CT-guided implantation of 125 I seeds was carried out first for cervical lesions, which was followed by PVP. For the thoracic and lumbar lesions, unilateral or bilateral puncturing with several particle needles was employed to implant the 125 I seeds, then, PVP with bone cement injection was performed. The complications and the clinical efficacy were analyzed. Results: Successful operation was obtained in all patients. The number of implanted 125 I seeds ranged from 4 to 30 per vertebra, and the volume of injected bone cement was 1-6 ml per vertebra. After the operation the pain relief rate was 86.9% (n=20). The incidence of bone cement leakage was 17.8% (5/28). One patient had radicular pain caused by neuropore leakage, which was relieved after medication. No serious complications, such as spinal cord injury or radiation myelitis, occurred. Conclusion: CT-guided PVP combined with 125 I-seed implantation is effective and safe for the treatment of metastatic vertebral carcinoma involving the spinal canal. This therapy can effectively relieve the pain and control the deterioration of tumor, besides, the incidence of bone cement leakage is very low. (authors)

  10. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  11. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  12. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Halpern, Elkan F. [Massachusetts General Hospital, Institute for Technology Assessment, Department of Radiology, Boston, MA (United States); Springfield, Dempsey S. [Massachusetts General Hospital, Department of Orthopedics, Boston, MA (United States)

    2015-12-15

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ{sup 2} test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a

  13. Percutaneous CT-guided needle biopsies of musculoskeletal tumors: a 5-year analysis of non-diagnostic biopsies

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Torriani, Martin; Rosenthal, Daniel I.; Halpern, Elkan F.; Springfield, Dempsey S.

    2015-01-01

    To study non-diagnostic CT-guided musculoskeletal biopsies and take steps to minimize them. Specifically we asked: (1) What malignant diagnoses have a higher non-diagnostic rate? (2) What factors of a non-diagnostic biopsy may warrant more aggressive pursuit? (3) Do intra-procedural frozen pathology (FP) or point-of-care (POC) cytology reduce the non-diagnostic biopsy rate ?This study was IRB-approved and HIPAA-compliant. We retrospectively reviewed 963 consecutive CT-guided musculoskeletal biopsies. We categorized pathology results as malignant, benign, or non-diagnostic and recorded use of FP or POC cytology. Initial biopsy indication, final diagnosis, method of obtaining the final diagnosis of non-diagnostic biopsies, age of the patient, and years of biopsy attending experience were recorded. Groups were compared using Pearson's χ 2 test or Fisher's exact test. In all, 140 of 963 (15 %) biopsies were non-diagnostic. Lymphoma resulted in more non-diagnostic biopsies (P < 0.0001). While 67% of non-diagnostic biopsies yielded benign diagnoses, 33% yielded malignant diagnoses. Patients whose percutaneous biopsy was indicated due to the clinical context without malignancy history almost always generated benign results (96 %). Whereas 56% of biopsies whose indication was an imaging finding of a treatable lesion were malignant, 20% of biopsies whose indication was a history of malignancy were malignant. There was no statistically significant difference in the nondiagnostic biopsy rates of pediatric versus adult patients (P = 0.8) and of biopsy attendings with fewer versus more years of experience (P = 0.5). The non-diagnostic rates of biopsies with FP (8 %), POC cytology (25 %), or neither (24 %) were significantly different (P < 0.0001). Lymphoma is the malignant diagnosis most likely to result in a non-diagnostic biopsy. If the clinical and radiologic suspicion for malignancy is high, repeat biopsy is warranted. If the clinical context suggests a benign

  14. PET/CT-guided biopsies of metabolically active bone lesions: applications and clinical impact

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, Bernd; Wartenberg, Jan; Weitzel, Thilo; Krause, Thomas [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); Wiskirchen, Jakub [Bern University Hospital and University of Bern, Department of Nuclear Medicine, Inselspital, Bern (Switzerland); University Hospital Tuebingen, Department of Radiology, Neuroradiology, and Nuclear Medicine, Tuebingen (Germany); Schmid, Ralph A. [Bern University Hospital and University of Bern, Department of Thoracic Surgery, Inselspital, Bern (Switzerland); Mueller, Michel D. [Bern University Hospital and University of Bern, Department of Obstetrics and Gynaecology, Inselspital, Bern (Switzerland)

    2010-11-15

    In a minority of cases a definite diagnosis and stage grouping in cancer patients is not possible based on the imaging information of PET/CT. We report our experience with percutaneous PET/CT-guided bone biopsies to histologically verify the aetiology of hypermetabolic bone lesions. We retrospectively reviewed the data of 20 consecutive patients who underwent multimodal image-guided bone biopsies using a dedicated PET/CT system in a step-by-step technique. Technical and clinical success rates of PET/CT-guided biopsies were evaluated. Questionnaires were sent to the referring physicians to assess the impact of biopsies on patient management and to check the clinical need for PET/CT-guided biopsies. Clinical indications for biopsy were to histologically verify the aetiology of metabolically active bone lesions without a morphological correlate confirming the suspicion of metastases in 15 patients, to determine the origin of suspected metastases in 3 patients and to evaluate the appropriateness of targeted therapy options in 2 patients. Biopsies were technically successful in all patients. In 19 of 20 patients a definite histological diagnosis was possible. No complications or adverse effects occurred. The result of PET/CT-guided bone biopsies determined a change of the planned treatment in overall 56% of patients, with intramodality changes, e.g. chemotherapy with palliative instead of curative intent, and intermodality changes, e.g. systemic therapy instead of surgery, in 22 and 50%, respectively. PET/CT-guided bone biopsies are a promising alternative to conventional techniques to make metabolically active bone lesions - especially without a distinctive morphological correlate - accessible for histological verification. PET/CT-guided biopsies had a major clinical impact in patients who otherwise cannot be reliably stage grouped at the time of treatment decisions. (orig.)

  15. The expressions of P53 protein and proliferating cell nuclear antigen in specimens by CT-guidance percutaneous lung biopsy

    International Nuclear Information System (INIS)

    Zhuang Yiping; Shen Zongli; Zhang Jin; Kang Zheng; Zhu Yueqing; Feng Yong; Shen Wenrong; Wang Yaping

    2004-01-01

    Objective: To evaluate relations between lung cancer and the expressions of P53 protein together with proliferating cell nuclear antigen (PCNA) in specimens of lung lesions by needle biopsy. Methods: CT-guidance percutaneous biopsy of lung lesions were performed in 66 patients with the determination of expressions of p53 protein and PCNA by flow cytometer (FCM). Results: 1. The sensitivity of CT-guidance percutaneous biopsy was 94.3% in 53 cases of lung cancer with the diagnostic accuracy of 90.9% totally. The complication rate of pneumothorax was 4.6%. 2. The expression of P53 protein was (29.9 ± 2.7)% in lung cancer (53 cases), while (17.9 ± 2.8)% in benign lesions (13 cases) (t=2.0, P 2 =6.10, P 2 =9.71, P 0.05). Conclusions: FCM plays and valuable role in determining the expression of P53 protein and PCNA in the specimen of lung cancer by CT-guided percutaneous biopsy. The expression of p53 and PCNA may be useful in the diagnosis of lung cancer by providing the relation between imaging of lung cancer and the molecular mechanism, and furthermore revealing the characteristics of molecular biology of lung cancer at protein level. (authors)

  16. Paravertebral Block: An Improved Method of Pain Control in Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Culp, William C.; McCowan, Timothy C.; DeValdenebro, Miguel; Wright, Lonnie B.; Workman, James L.; Culp, William C.

    2006-01-01

    Background and Purpose. Percutaneous transhepatic biliary drainage remains a painful procedure in many cases despite the routine use of large amounts of intravenous sedation. We present a feasibility study of thoracic paravertebral blocks in an effort to reduce pain during and following the procedure and reduce requirements for intravenous sedation. Methods. Ten consecutive patients undergoing biliary drainage procedures received fluoroscopically guided paravertebral blocks and then had supplemental intravenous sedation as required to maintain patient comfort. Levels T8-T9 and T9-T10 on the right were targeted with 10-20 ml of 0.5% bupivacaine. Sedation requirements and pain levels were recorded. Results. Ten biliary drainage procedures in 8 patients were performed for malignancy in 8 cases and for stones in 2. The mean midazolam use was 1.13 mg IV, and the mean fentanyl requirement was 60.0 μg IV in the block patients. Two episodes of hypotension, which responded promptly to volume replacement, may have been related to the block. No serious complications were encountered. The mean pain score when traversing the chest wall, liver capsule, and upon entering the bile ducts was 0.1 on a scale of 0 to 10, with 1 patient reporting a pain level of 1 and 9 reporting 0. The mean peak pain score, encountered when manipulating at the common bile duct level or when addressing stones there, was 5.4 and ranged from 0 to 10. Conclusions. Thoracic paravertebral block with intravenous sedation supplementation appears to be a feasible method of pain control during biliary interventions

  17. Emergency percutaneous treatment in surgical bile duct injury.

    Science.gov (United States)

    Carrafiello, Gianpaolo; Laganà, Domenico; Dizonno, Massimiliano; Ianniello, Andrea; Cotta, Elisa; Dionigi, Gianlorenzo; Dionigi, Renzo; Fugazzola, Carlo

    2008-09-01

    The aim of this study is to evaluate the efficacy of emergency percutaneous treatment in patients with surgical bile duct injury (SBDI). From May 2004 to May 2007, 11 patients (five men, six women; age range 26-80 years; mean age 58 years) with a critical clinical picture (severe jaundice, bile peritonitis, septic state) due to SBDI secondary to surgical or laparoscopic procedures were treated by percutaneous procedures. We performed four ultrasound-guided percutaneous drainages, four external-internal biliary drainages, one bilioplasty, and two plastic biliary stenting after 2 weeks of external-internal biliary drainage placement. All procedures had 100% technical success with no complications. The clinical emergencies resolved in 3-4 days in 100% of cases. All patients had a benign clinical course, and reoperation was avoided in 100% of cases. Interventional radiological procedures are effective in the emergency management of SBDI since they are minimally invasive and have a high success rate and a low incidence of complications compared to the more complex and dangerous surgical or laparoscopic options.

  18. Long-term Results after CT-Guided Percutaneous Ethanol Ablation for the Treatment of Hyperfunctioning Adrenal Disorders

    Directory of Open Access Journals (Sweden)

    Nathan Elie Frenk

    Full Text Available OBJECTIVES: To evaluate the safety and long-term efficacy of computed tomography-guided percutaneous ethanol ablation for benign primary and secondary hyperfunctioning adrenal disorders. METHOD: We retrospectively evaluated the long-term results of nine patients treated with computed tomography-guided percutaneous ethanol ablation: eight subjects who presented with primary adrenal disorders, such as pheochromocytoma, primary macronodular adrenal hyperplasia and aldosterone-producing adenoma, and one subject with Cushing disease refractory to conventional treatment. Eleven sessions were performed for the nine patients. The patient data were reviewed for the clinical outcome and procedure-related complications over ten years. RESULTS: Patients with aldosterone-producing adenoma had clinical improvement: symptoms recurred in one case 96 months after ethanol ablation, and the other patient was still in remission 110 months later. All patients with pheochromocytoma had clinical improvement but were eventually submitted to surgery for complete remission. No significant clinical improvement was seen in patients with hypercortisolism due to primary macronodular adrenal hyperplasia or Cushing disease. Major complications were seen in five of the eleven procedures and included cardiovascular instability and myocardial infarction. Minor complications attributed to sedation were seen in two patients. CONCLUSION: Computed tomography-guided ethanol ablation does not appear to be suitable for the long-term treatment of hyperfunctioning adrenal disorders and is not without risks.

  19. A case of lung abscess successfully treated by transbronchial drainage using a guide sheath.

    Science.gov (United States)

    Izumi, Hiroki; Kodani, Masahiro; Matsumoto, Shingo; Kawasaki, Yuji; Igishi, Tadashi; Shimizu, Eiji

    2017-05-01

    A 51-year-old man was diagnosed with colon cancer in September 2011, and a solitary pulmonary nodule was detected by computed tomography (CT) scan. We performed a transbronchial biopsy with endobronchial ultrasonography using a guide sheath (GS) and diagnosed lung metastasis of colon cancer. The patient experienced remittent fever after the biopsy in spite of intravenous antibiotic therapies. Moreover, his CT scan showed a large lung abscess at the biopsy site. We performed transbronchial drainage using a GS as salvage therapy. The bloody pus was successfully aspirated, and chest X-ray following the procedure showed dramatic shrinkage of the abscess.

  20. A case of transitional cell carcinoma associated with pericalyceal diverticulum diagnosed by CT guided percutaneous cystgraphy

    International Nuclear Information System (INIS)

    Sasaki, Fumio; Koga, Sukehiko; Takeuchi, Akira; Anno, Hirofumi; Hujita, Tamio

    1983-01-01

    Computed tomography (CT) performed on a 42-year-old male patient with a chief complaint of hematuria revealed a renal cyst with a thickened and irregularly shaped wall. CT with contrast medium injected into the cyst by puncture under CT guide detected tumors on the cystic wall preoperatively. (Ueda, J.)

  1. Volume navigation with contrast enhanced ultrasound and image fusion for percutaneous interventions: first results.

    Directory of Open Access Journals (Sweden)

    Ernst Michael Jung

    Full Text Available OBJECTIVE: Assessing the feasibility and efficiency of interventions using ultrasound (US volume navigation (V Nav with real time needle tracking and image fusion with contrast enhanced (ce CT, MRI or US. METHODS: First an in vitro study on a liver phantom with CT data image fusion was performed, involving the puncture of a 10 mm lesion in a depth of 5 cm performed by 15 examiners with US guided freehand technique vs. V Nav for the purpose of time optimization. Then 23 patients underwent ultrasound-navigated biopsies or interventions using V Nav image fusion of live ultrasound with ceCT, ceMRI or CEUS, which were acquired before the intervention. A CEUS data set was acquired in all patients. Image fusion was established for CEUS and CT or CEUS and MRI using anatomical landmarks in the area of the targeted lesion. The definition of a virtual biopsy line with navigational axes targeting the lesion was achieved by the usage of sterile trocar with a magnetic sensor embedded in its distal tip employing a dedicated navigation software for real time needle tracking. RESULTS: The in vitro study showed significantly less time needed for the simulated interventions in all examiners when V Nav was used (p<0.05. In the study involving patients, in all 10 biopsies of suspect lesions of the liver a histological confirmation was achieved. We also used V Nav for a breast biopsy (intraductal carcinoma, for a biopsy of the abdominal wall (metastasis of ovarial carcinoma and for radiofrequency ablations (4 ablations. In 8 cases of inflammatory abdominal lesions 9 percutaneous drainages were successfully inserted. CONCLUSION: Percutaneous biopsies and drainages, even of small lesions involving complex access pathways, can be accomplished with a high success rate by using 3D real time image fusion together with real time needle tracking.

  2. Ultrasound-Guided Percutaneous Catheter Drainage of Large Breast Abscesses in Lactating Women: How to Preserve Breastfeeding Safely.

    Science.gov (United States)

    Falco, Giuseppe; Foroni, Monica; Castagnetti, Fabio; Marano, Luigi; Bordoni, Daniele; Rocco, Nicola; Marchesi, Vanessa; Iotti, Valentina; Vacondio, Rita; Ferrari, Guglielmo

    2016-12-01

    Management of breast abscess in lactating women remains controversial. During pregnancy, women may develop different kinds of benign breast lesions that could require a surgical incision performed under general anesthesia with consequent breastfeeding interruption. The purpose of this study was to prospectively evaluate the management of large breast abscesses with ultrasound-assisted drainage aiming at breastfeeding preservation. 34 lactating women with a diagnosis of unilateral breast abscess have been treated with an ultrasound (US)-assisted drainage of the abscess. A pigtail catheter was inserted into the fluid collection using the Seldinger technique under US guide and connected to a three stop way to allow drainage and irrigation of the cavity until its resolution. All procedures have been found safe and well tolerated. No recurrence was observed and breastfeeding was never interrupted. The described technique allows to avoid surgery and to preserve breastfeeding in well-selected patients with a safe, well-tolerated and cost-effective procedure.

  3. C.T. criteria of the differential diagnosis in primary retroperitoneal masses

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Procacci, C.; Caudana, R.; Bergamo Andreis, I.A.; Manera, V.; Recla, M.; Grasso, G.; Florio, C.

    1984-01-01

    This personal series of 44 primary retroperitoneal masses (P.R.P.M.) studied by C.T. is analyzed. The reliability of C.T. in the identification (44/44), characterization (43/44) and origin evaluation (41/44) of P.R.P.M. has been absolutely satisfactory. In particular, those criteria of C.T. diagnosis which may be utilized in the evaluation of the origin of upper abdominal masses are thoroughly described. The evaluation of the involvement (non invasive; invasive) of adjacent viscera has been achieved in 22/38 P.R.P.M. verified at operation. The evaluation of tumour resectability has been less reliable due to the high incidence of under-diagnosis (60% in our personal experience). C.T. may be used in addition as an aid to different diagnostic techniques (percutaneous guided needle biopsy) or to therapy (drainage of retroperitoneal abscesses). C.T. is absolutely necessary in the follow-up of P.R.P.M. after surgery, radiotherapy or chemotherapy. (orig.)

  4. CT-Guided Microwave Ablation of 45 Renal Tumors: Analysis of Procedure Complexity Utilizing a Percutaneous Renal Ablation Complexity Scoring System.

    Science.gov (United States)

    Mansilla, Alberto V; Bivins, Eugene E; Contreras, Francisco; Hernandez, Manuel A; Kohler, Nathan; Pepe, Julie W

    2017-02-01

    To develop a scoring system that stratifies complexity of percutaneous ablation of renal tumors. Analysis was performed of 36 consecutive patients (mean age, 64 y; range, 30-89 y) who underwent CT-guided microwave (MW) ablation of 45 renal tumors (mean tumor diameter, 2.4 cm; range, 1.2-4.0 cm). Technical success and effectiveness were determined based on intraprocedural and follow-up imaging studies. The RENAL score and the proposed percutaneous renal ablation complexity (P-RAC) score were calculated for each tumor. Technical success was 93.3% (n = 42). Biopsy of 38 of 45 renal tumors revealed 23 renal cell carcinomas. Median follow-up period was 9.7 months (range, 2.9-46.8 months). There were no tumor recurrences. One major complication, ureteropelvic junction stricture, occurred (2.6%). The P-RAC score was found to differ statistically from the RENAL score (t = 3.754, df = 44, P = .001). A positive correlation was found between the P-RAC score and number of antenna insertions (r = .378, n = 45, P = .011) and procedure duration (r = .328, n = 45, P = .028). No correlation was found between the RENAL score and number of MW antenna insertions (r = .110, n = 45, P = .472) or procedure duration (r = .263, n = 45, P = .081). Hydrodissection was significantly more common in the P-RAC high-complexity category than in low-complexity category (χ 2 = 12.073, df = 2, P = .002). The P-RAC score may be useful in stratifying percutaneous renal ablation complexity. Further studies with larger sample sizes are necessary to validate the P-RAC score and to determine if it can predict risk of complications. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  5. CT-guided percutaneous neurolysis methods. State of the art and first results; CT-gesteuerte Neurolysen. Stand der Technik und aktuelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, B. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Richter, G.M. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Roeren, T. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany); Kauffmann, G.W. [Abt. Radiodiagnostik, Radiologische Universitaetsklinik Heidelberg (Germany)

    1996-09-01

    We used 21G or 22G fine needles. All CT-guided percutaneous neurolysis methods require a proper blood coagulation. Most common CT scanners are suitable for neurolysis if there is enough room for maintaining sterile conditions. All neurolysis methods involve sterile puncture of the ganglia under local anesthesia, a test block with anesthetic and contrast agent to assess the clinical effect and the definitive block with a mixture of 96% ethanol and local anesthetic. This allows us to correct the position of the needle if we see improper distribution of the test block or unwanted side effects. Though inflammatory complications of the peritoneum due to puncture are rarely seen, we prefer the dorsal approach whenever possible. Results: Seven of 20 legs showed at least transient clinical improvement after CT-guided lumbar sympathectomies; 13 legs had to be amputated. Results of the methods in the literature differ. For lumbar sympathectomy, improved perfusion is reported in 39-89%, depending on the pre-selection of the patient group. Discussion: It was recently proved that sympathectomy not only improves perfusion of the skin but also of the muscle. The hypothesis of a steal effect after sympathectomy towards skin perfusion was disproved. Modern aggressive surgical and interventional treatment often leaves patients to sympathectomy whose reservers of collateralization are nearly exhausted. We presume this is the reason for the different results we found in our patient group. For thoracic sympathectomy the clinical treatment depends very much on the indications. Whereas palmar hyperhidrosis offers nearly 100% success, only 60-70% of patients with disturbance of perfusion have benefited. Results in celiac ganglia block also differ. Patients with carcinoma of the pancreas and other organs of the upper abdomen benefit in 80-100% of all cases, patients with chronic pancreatitis in 60-80%. (orig./VHE) [Deutsch] Thorakale und lumbale Sympathikolyse sowie die Zoeliakusblockade

  6. Safety and efficacy analysis of ultrasound-guided percutaneous transhepatic biliary drainage treatment of malignant obstructive jaundice

    Directory of Open Access Journals (Sweden)

    Ye Ben-Gong

    2016-08-01

    Full Text Available Objective: To study the clinical effect and prognosis of percutaneous transhepatic biliary drainage (PTBD treatment of patients with malignant obstructive jaundice. Methods: A total of 112 patients with malignant obstructive jaundice treated in our hospital from April 2009 to February 2014 were retrospectively analyzed. All patients were randomly divided into control group (42 cases and observation group (70 cases, control group received drainage of laparotomy and observation group received PTBD intervention. All patients were followed up for 3 to 23 months. Clinical effect, complication and length of stay were observed and counted after two groups received different treatment, and the results were compared and analyzed. Results: After two groups received different treatment, serum AIL, AST, TBIL and DBIL levels significantly decreased than before treatment, but serum AIL, AST, TBIL and DBIL levels of observation group were lower than those of control group. The levels of WBC and NE of both groups were lower than before treatment, but differences in WBC, NE and PT between the two groups were without statistical significance after treatment. Meanwhile, the incidence of adverse reaction and length of stay of observation group were lower than those of control group, and the differences were statistically significant. Conclusion: Interventional treatment of malignant obstructive jaundice can effectively improve the clinical symptoms, lower incidence of adverse reactions and shorten the length of stay, which is the preferred method for medically inoperable malignant obstructive jaundice and worth clinical popularization.

  7. Application of Real-Time 3D Navigation System in CT-Guided Percutaneous Interventional Procedures: A Feasibility Study

    Directory of Open Access Journals (Sweden)

    Priya Bhattacharji

    2017-01-01

    Full Text Available Introduction. To evaluate the accuracy of a quantitative 3D navigation system for CT-guided interventional procedures in a two-part study. Materials and Methods. Twenty-two procedures were performed in abdominal and thoracic phantoms. Accuracies of the 3D anatomy map registration and navigation were evaluated. Time used for the navigated procedures was recorded. In the IRB approved clinical evaluation, 21 patients scheduled for CT-guided thoracic and hepatic biopsy and ablations were recruited. CT-guided procedures were performed without following the 3D navigation display. Accuracy of navigation as well as workflow fitness of the system was evaluated. Results. In phantoms, the average 3D anatomy map registration error was 1.79 mm. The average navigated needle placement accuracy for one-pass and two-pass procedures, respectively, was 2.0±0.7 mm and 2.8±1.1 mm in the liver and 2.7±1.7 mm and 3.0±1.4 mm in the lung. The average accuracy of the 3D navigation system in human subjects was 4.6 mm ± 3.1 for all procedures. The system fits the existing workflow of CT-guided interventions with minimum impact. Conclusion. A 3D navigation system can be performed along the existing workflow and has the potential to navigate precision needle placement in CT-guided interventional procedures.

  8. Prospective evaluation of the radiologist's hand dose in CT-guided interventions; Prospektive Evaluation der Handdosis des Radiologen im Rahmen von CT-gestuetzten Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Kropf, S. [Magdeburg Univ. (Germany). Dept. of Biometry and Medical Informatics; Nekolla, E.A. [The Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Radiation Protection and Health; Wieners, G. [Charite CVC, Berlin (Germany). Dept. of Radiology

    2013-11-15

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  9. Ultrasound-guided percutaneous bone drilling for the treatment of lateral epicondylitis.

    Science.gov (United States)

    Yoo, Sang Ho; Cha, Jang Gyu; Lee, Bo Ra

    2018-01-01

    To determine the clinical efficacy of sonographically-guided percutaneous bone drilling of the lateral epicondyle (LE) for the treatment of patients with LE. We included 24 patients with LE who reported pain in this study. All patients underwent sonographically-guided percutaneous bone drilling of the lateral epicondyle. Follow-up sonography and physical examinations were performed 1, 3 and 6 months after the procedure. The outcome measures included sonographic findings, visual analogue scale (VAS) score, maximum voluntary grip strength (MVGS) and patient-related tennis elbow evaluation (PRTEE) score. None of the patients had immediate complications during the procedure. The area of the extensor carpi radialis brevis (ECRB) tears decreased significantly at 1 month and declined gradually over the remaining 5 months of the study (p LE that can be performed in an outpatient setting. • Percutaneous drilling of the lateral condyle is effective for the treatment of LE. • The area of ECRB tears can be measured by US-guided saline injection. • US-guided percutaneous drilling is a quick and safe treatment option for LE.

  10. Sacral-neuromodulation CT-guided

    International Nuclear Information System (INIS)

    Amoroso, Lamberto; Ricci, Stefano; Pelliccioni, Giuseppe; Scarpino, Osvaldo; Ghiselli, Roberto; Saba, Vittorio

    2005-01-01

    Purpose: Sacral neuromodulation is a new treatment for refractory voiding disorders such as urge incontinence, urinary retention, frequency-urgency syndromes and faecal incontinence. The current approach to sacral nerve stimulation consists of a two-stage procedure. The first is a PNE test (Percutaneous Nerve Evaluation) by a provisional electrically stimulated spinal needle, placed percutaneously in the S3 foramina for four of ten days. If successful, the second stage, permanent implantation, is carried out. The PNE test is performed under fluoroscopic control using the palpable bony sacral foramina as referral points. This technique can show some limitations, such as operator Rx exposure, poor visualization of sacral foramina because of bowel gas artefacts or sacral malformation. In order to reduce these inconveniences and to improve efficiency of the test we tried an alternative technique. The purpose of our study was to test the use of CT as an alternative technique in order to evaluate its advantages and possible routine use. Materials and methods: We tested 30 patients with the PNE test under CT guidance (16 males and 14 females) suffering from serious pelvic disorders and not responding to the normal therapeutic regime. Twenty-seven patient showed relative anatomical integrity of the pelvis and the sacrum, the remaining 3 patients presented morphological anormalities of the sacral foramina. With the patient in the prone position the sacral foramina were identified with CT volumetric scanning using a spiral CT scanner equipped with a second console for the three-dimensional reconstructions. Having identified the location of the S3 foramina, a sterile field was prepared and the spiral needle introduced checking correct positioning with a CT control scan. An electrode was inserted after having checked correct muscular contractile response and the precise position with a further CT scan. Results: Thirty patients were subjected to PNE under CT guidance for a

  11. CT findings in gastrocolic fistula following percutaneous endoscopic gastrostomy

    International Nuclear Information System (INIS)

    Brown, Suki; McHugh, Kieran; Ledermann, Sarah; Pierro, Agostino

    2007-01-01

    We describe the CT findings in an initially asymptomatic boy aged 2 years 9 months with a gastrocolic fistula following percutaneous endoscopic gastrostomy (PEG) placement. The findings consisted of an unusual configuration of the gastrostomy tubing on an abdominal radiograph and upper gastrointestinal study indicating the possibility of transcolic PEG placement, which was confirmed with limited section CT. This well-known and major complication following a common procedure may be recognized on plain abdominal radiography, but it has not to our knowledge been documented previously on CT in a child. (orig.)

  12. CT findings in gastrocolic fistula following percutaneous endoscopic gastrostomy

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Suki [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); St. George' s Hospital, Radiology Department, London (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom); Ledermann, Sarah [Great Ormond Street Hospital for Children, Department of Nephrology, London (United Kingdom); Pierro, Agostino [Great Ormond Street Hospital for Children, Department of Surgery, London (United Kingdom)

    2007-02-15

    We describe the CT findings in an initially asymptomatic boy aged 2 years 9 months with a gastrocolic fistula following percutaneous endoscopic gastrostomy (PEG) placement. The findings consisted of an unusual configuration of the gastrostomy tubing on an abdominal radiograph and upper gastrointestinal study indicating the possibility of transcolic PEG placement, which was confirmed with limited section CT. This well-known and major complication following a common procedure may be recognized on plain abdominal radiography, but it has not to our knowledge been documented previously on CT in a child. (orig.)

  13. Biloma: radiologic diagnosis and treatment

    International Nuclear Information System (INIS)

    Kim, Hong; Woo, Yung Hoon; Woo, Seong Ku

    1990-01-01

    The localized intraabdominal bile collection or biloma has recently been diagnosed in increased frequently due to the wide spread use of US, CT, DISIDA scintigram, and radiologically guided percutaneous needle aspiration with or without subsequent catheter drainage. The underlying cause of biloma is trauma or iatrogenic injury which includes abdominal surgery, percutaneous drainage or PTC. We experience 20 patients with 22 biloma diagnostically confirmed by DISIDA scan, image-guided needle aspiration, percutaneous catheter drainage and / or operation. Of the 22 biloma, 7 were intrahepatic and 15 were extrahepatic. Of the 15 extrahepatic biloma, 7 were in partially hepatectomized bed, 3 were subhepatic, 3 were right subphrenic and 1 was subcapsular. We were able to determine the infectivity in 16 biloma and of these 12 biloma were found to be infected. Percutaneous drainage was performed on 20 biloma in 18 patients : by a needle aspiration with irrigation on 2 patient and by percutaneous catheter drainage on 18 bilomas. Overall success rate of the drainage was 90%. Cause of the two failures were CHD stone with choledochoduodenal fistula and recurrent hemobilia with acute cholecystitis. We describe the processes in reaching the diagnosis of biloma, propensity of biloma to purulent intrahepatic or perihepatic abscess formation, and the necessity of percutaneous radiologic catheter drainage as an optional management

  14. Endoscopic Ultrasound-guided Drainage of Pancreatic Pseudocysts

    DEFF Research Database (Denmark)

    Ng, Pui Yung; Nytoft Rasmussen, Ditlev; Vilmann, Peter

    2013-01-01

    or by telephonic interview. RESULTS: A total of 61 procedures were performed. The symptoms that indicated drainage were abdominal pain (n = 43), vomiting (n = 7) and jaundice (n = 5). The procedure was technically successful in 57 of the 61 procedures (93%). The immediate complication rate was 5%. At a mean follow......-up of 45 weeks, the treatment success was 75%. The medium term complications appeared in 25% of cases, which included three cases each of stent clogging, stent migration, infection and six cases of recurrence. There was no mortality. CONCLUSION: EUS-guided drainage is an effective treatment for PPC...... with a successful outcome in most of patients. Most of the complications require minimal invasive surgical treatment or repeated EUS-guided drainage procedures....

  15. Complications of percutaneous transhepatic biliary drainage in patients with dilated and nondilated intrahepatic bile ducts

    International Nuclear Information System (INIS)

    Weber, Andreas; Gaa, Jochen; Rosca, Bogdan; Born, Peter; Neu, Bruno; Schmid, Roland M.; Prinz, Christian

    2009-01-01

    Percutaneous transhepatic biliary drainage (PTBD) have been described as an effective technique to obtain biliary access. Between January 1996 and December 2006, a total of 419 consecutive patients with endoscopically inaccessible bile ducts underwent PTBD. The current retrospective study evaluated success and complication rates of this invasive technique. PTBD was successful in 410/419 patients (97%). The success rate was equal in patients with dilated and nondilated bile ducts (p = 0.820). In 39/419 patients (9%) procedure related complications could be observed. Major complications occurred in 17/419 patients (4%). Patients with nondilated intrahepatic bile ducts had significantly higher complication rates compared to patients with dilated intrahepatic bile ducts (14.5% vs. 6.9%, respectively [p = 0.022]). Procedure related deaths were observed in 3 patients (0.7%). In conclusion, percutaneous transhepatic biliary drainage is an effective procedure in patients with dilated and nondilated intrahepatic bile ducts. However, patients with nondilated intrahepatic bile ducts showed a higher risk for procedure related complications.

  16. Long-term results after CT-guided percutaneous ethanol ablation for the treatment of hyper functioning adrenal disorders

    International Nuclear Information System (INIS)

    Frenk, Nathan Elie; Sebastianes, Fernando; Lerario, Antonio Marcondes; Fragoso, Maria Candida Barisson Villares; Mendonca, Berenice Bilharinho

    2016-01-01

    Objectives: To evaluate the safety and long-term efficacy of computed tomography-guided percutaneous ethanol ablation for benign primary and secondary hyper functioning adrenal disorders. Method: We retrospectively evaluated the long-term results of nine patients treated with computed tomography guided percutaneous ethanol ablation: eight subjects who presented with primary adrenal disorders, such as pheochromocytoma, primary macro nodular adrenal hyperplasia and aldosterone-producing adenoma, and one subject with Cushing disease refractory to conventional treatment. Eleven sessions were performed for the nine patients. The patient data were reviewed for the clinical outcome and procedure-related complications over ten years. Results: Patients with aldosterone-producing adenoma had clinical improvement: symptoms recurred in one case 96 months after ethanol ablation, and the other patient was still in remission 110 months later. All patients with pheochromocytoma had clinical improvement but were eventually submitted to surgery for complete remission. No significant clinical improvement was seen in patients with hypercortisolism due to primary macro nodular adrenal hyperplasia or Cushing disease. Major complications were seen in five of the eleven procedures and included cardiovascular instability and myocardial infarction. Minor complications attributed to sedation were seen in two patients. Conclusion: Computed tomography-guided ethanol ablation does not appear to be suitable for the long-term treatment of hyper functioning adrenal disorders and is not without risks. (author)

  17. Long-term results after CT-guided percutaneous ethanol ablation for the treatment of hyper functioning adrenal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Frenk, Nathan Elie; Sebastianes, Fernando; Lerario, Antonio Marcondes; Fragoso, Maria Candida Barisson Villares; Mendonca, Berenice Bilharinho [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina; Menezes, Marcos Roberto de, E-mail: menezesmr@gmail.com [Instituto do Cancer do Estado de Sao Paulo, SP (Brazil)

    2016-10-15

    Objectives: To evaluate the safety and long-term efficacy of computed tomography-guided percutaneous ethanol ablation for benign primary and secondary hyper functioning adrenal disorders. Method: We retrospectively evaluated the long-term results of nine patients treated with computed tomography guided percutaneous ethanol ablation: eight subjects who presented with primary adrenal disorders, such as pheochromocytoma, primary macro nodular adrenal hyperplasia and aldosterone-producing adenoma, and one subject with Cushing disease refractory to conventional treatment. Eleven sessions were performed for the nine patients. The patient data were reviewed for the clinical outcome and procedure-related complications over ten years. Results: Patients with aldosterone-producing adenoma had clinical improvement: symptoms recurred in one case 96 months after ethanol ablation, and the other patient was still in remission 110 months later. All patients with pheochromocytoma had clinical improvement but were eventually submitted to surgery for complete remission. No significant clinical improvement was seen in patients with hypercortisolism due to primary macro nodular adrenal hyperplasia or Cushing disease. Major complications were seen in five of the eleven procedures and included cardiovascular instability and myocardial infarction. Minor complications attributed to sedation were seen in two patients. Conclusion: Computed tomography-guided ethanol ablation does not appear to be suitable for the long-term treatment of hyper functioning adrenal disorders and is not without risks. (author)

  18. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method.

    Science.gov (United States)

    Kakizawa, Hideaki; Toyota, Naoyuki; Hieda, Masashi; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Oda, Miyo; Ito, Katsuhide

    2010-09-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: "none", "mild", "moderate" and "severe". The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p < 0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax.

  19. Risk factors for severity of pneumothorax after CT-guided percutaneous lung biopsy using the single-needle method

    International Nuclear Information System (INIS)

    Kakizawa, Hideaki; Hieda, Masashi; Oda, Miyo; Toyota, Naoyuki; Hirai, Nobuhiko; Tachikake, Toshihiro; Matsuura, Noriaki; Ito, Katsuhide

    2010-01-01

    The purpose of this study is to evaluate the risk factors for the severity of pneumothorax after computed tomography (CT)-guided percutaneous lung biopsy using the single-needle method. We reviewed 91 biopsy procedures for 90 intrapulmonary lesions in 89 patients. Patient factors were age, sex, history of ipsilateral lung surgery and grade of emphysema. Lesion factors were size, location and pleural contact. Procedure factors were position, needle type, needle size, number of pleural punctures, pleural angle, length of needle passes in the aerated lung and number of harvesting samples. The severity of pneumothorax after biopsy was classified into 4 groups: 'none', 'mild', 'moderate' and 'severe'. The risk factors for the severity of pneumothorax were determined by multivariate analyzing of the factors derived from univariate analysis. Pneumothorax occurred in 39 (43%) of the 91 procedures. Mild, moderate, and severe pneumothorax occurred in 24 (26%), 8 (9%) and 7 (8%) of all procedures, respectively. Multivariate analysis showed that location, pleural contact, number of pleural punctures and number of harvesting samples were significantly associated with the severity of pneumothorax (p<0.05). In conclusion, lower locations and non-pleural contact lesions, increased number of pleural punctures and increased number of harvesting samples presented a higher severity of pneumothorax. (author)

  20. Analysis of different ways of drainage for obstructive jaundice caused by hilar cholangiocarcinoma.

    Science.gov (United States)

    Xu, Chuan; Lv, Peng-Hua; Huang, Xin-En; Wang, Shu-Xiang; Sun, Ling; Wang, Fu-An

    2014-01-01

    To evaluate the prognosis of different ways of drainage for patients with obstructive jaundice caused by hilar cholangiocarcinoma. During the period of January 2006- March 2012, percutaneous transhepatic catheter drainage (PTCD)/ percutaneous transhepatic biliary stenting (PTBS) were performed for 89 patients. According to percutaneous transhepatic cholangiography (PTC), external drainage was selected if the region of obstruction could not be passed by guide wire or a metallic stent was inserted if it could. External drainage was the first choice if infection was diagnosed before the procedure, and a metallic stent was inserted in one week after the infection was under control. Selection by new infections, the degree of bilirubin decrease, the change of ALT, the time of recurrence of obstruction, and the survival time of patients as the parameters was conducted to evaluate the methods of different interventional treatments regarding prognosis of patients with hilar obstruction caused by hilar cholangiocarcinoma. PTCD was conducted in 6 patients and PTBS in 7 (pPTBS was 243 days (pPTBS was found to be better than PTCD for prolonging the patient survival.

  1. CT-guided core biopsy and percutaneous fiducial seed placement in the lung: Can these procedures be combined without an increase in complication rate or decrease in technical success?

    Energy Technology Data Exchange (ETDEWEB)

    Mendiratta-Lala, Mishal [Henry Ford Hospital, Department of Radiology, Abdominal Interventional Radiology, 2799 West Grand Blvd, Detroit, MI 48202 (United States); Sheiman, Robert, E-mail: rsheiman@bidmc.harvard.edu [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Brook, Olga R. [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States); Gourtsoyianni, Sofia [King' s College London, St Thomas’ Hospital, Lambeth Palace Road, SE1 7EH London (United Kingdom); Mahadevan, Anand [Beth Israel Deaconess Hospital, Radiation Oncology, One Deaconess Road, Boston, MA 02215 (United States); Siewert, Bettina [Beth Israel Deaconess Hospital, Department of Radiology, Abdominal Imaging, One Deaconess Road, Boston, MA 02215 (United States)

    2014-04-15

    Objective: To determine if concomitant CT-guided biopsy and percutaneous fiducial seed placement in the lung can be performed in a selective patient population without increased complication or decreased success rates compared to either procedure alone. Materials and methods: An IRB approved retrospective analysis of 285 consecutive patients that underwent CT-guided placement of fiducial seeds in the lung alone (N = 63), with concomitant core biopsy (N = 53) or only core biopsy (N = 169) was performed. Variables compared included: patient demographics, lesion size, depth from pleura, needle size, number of passes through pleura, number and size of core biopsies, number of seeds placed and technical success rates. Statistical analysis was performed using univariate and multivariate pair-wise comparisons. Results: A pathologic diagnosis of malignancy was confirmed in all cases undergoing seed placement alone and seed placement with concurrent biopsy, and in 144 of the biopsy alone lesions. On univariate analysis, major complication rates were similar for all three groups as were lesion size, depth, number of pleural passes, and technical success. Pair-wise comparisons of the remaining variables demonstrated a significant younger age and smaller needle size in the biopsy only group, and less minor complications in the fiducial only group. Overall there were 80/285 (28.1%) minor and 29/285 (10.2%) major complications. All major complications leading to admission consisted of either pneumothorax or hemothorax, while minor complications included asymptomatic stable or resolving pneumothoraces, transient hemoptysis or small hemothoraces. Conclusions: A combined procedure of percutaneous pulmonary core biopsy and stereotactic seed placement can be performed without additional risk of a major complication when compared to performing these separately.

  2. Endoscopic Ultrasonography-Guided Techniques for Accessing and Draining the Biliary System and the Pancreatic Duct.

    Science.gov (United States)

    Rimbaş, Mihai; Larghi, Alberto

    2017-10-01

    When endoscopic retrograde cholangiopancreatography (ERCP) fails to decompress the biliary system or the pancreatic duct, endoscopic ultrasonography (EUS)-guided biliary or pancreatic access and drainage can be used. Data show a high success rate and acceptable adverse event rate for EUS-guided biliary drainage. The outcomes of EUS-guided biliary drainage seem equivalent to percutaneous drainage and ERCP, whereas only retrospective studies are available for pancreatic duct drainage. In this article, revision of the technical and clinical status and the current evidence of interventional EUS-guided biliary and pancreatic duct access and drainage are presented. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Non-real-time computed tomography-guided percutaneous ethanol injection therapy for heapocellular carcinoma undetectable by ultrasonography

    International Nuclear Information System (INIS)

    Ueda, Kazushige; Ohkawara, Tohru; Minami, Masahito; Sawa, Yoshihiko; Morinaga, Osamu; Kohli, Yoshihiro; Ohkawara, Yasuo

    1998-01-01

    The purpose of this study was to evaluate the feasibility of non-real-time CT-guided percutaneous ethanol injection therapy (PEIT) for hepatocellular carcinoma (HCC, 37 lesions) untreatable by ultrasonography-guided (US)-PEIT. The HCC lesion was localized on the lipiodol CT image with a graduated grid system. We advanced a 21 G or 22 G needle in a stepwise fashion with intermittent localization scans using a tandem method to position the tip of the needle in the lesion. Ethanol containing contrast medium was injected with monitoring scans obtained after incremental volumes of injection, until perfusion of the lesion was judged to be complete. A total of 44 CT-PEIT procedures were performed. The average number of needle passes from the skin to the liver in each CT-PEIT procedure was 2.3, the average amount of ethanol injected was 14.4 ml, and the average time required was 49.3 minutes. Complete perfusion of the lesion by ethanol on monitoring CT images was achieved in all lesions with only a single or double CT-PEIT procedure without severe complication. Local recurrence was detected only in 5 lesions. At present, it is more time-consuming to perform CT-PEIT than US-PEIT because conventional CT guidance is not real-time imaging. However, it is expected that this limitation of CT-PEIT will be overcome in the near future with the introduction of CT fluoroscopy. In conclusion, CT-PEIT should prove to be a feasible, acceptable treatment for challenging cases of HCC undetectable by US. (author)

  4. C-arm cone-beam CT virtual navigation-guided percutaneous mediastinal mass biopsy: Diagnostic accuracy and complications

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungjin [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Aerospace Medical Group, Air Force Education and Training Command, Jinju (Korea, Republic of); Park, Chang Min; Goo, Jin Mo [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Lee, Sang Min [Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2015-12-15

    To assess the usefulness of C-arm cone-beam computed tomography (CBCT) virtual navigation-guided percutaneous mediastinal mass biopsy in terms of diagnostic accuracy and complication rates. Seventy-eight CBCT virtual navigation-guided percutaneous mediastinal mass biopsies were performed in 75 patients (M:F, 38:37; mean age, 48.55 ± 18.76 years). The procedural details, diagnostic sensitivity, specificity, accuracy and complication rate were investigated. Mean lesion size was 6.80 ± 3.08 cm, skin-to-target distance was 3.67 ± 1.80 cm, core needle biopsy rate was 96.2 % (75/78), needle indwelling time was 9.29 ± 4.34 min, total procedure time was 13.26 ± 5.29 min, number of biopsy specimens obtained was 3.13 ± 1.02, number of CBCTs performed was 3.03 ± 0.68, rate of lesion border discrimination from abutting mediastinal structures on CBCT was 26.9 % (21/78), technical success rate was 100 % (78/78), estimated effective dose was 5.33 ± 4.99 mSv, and the dose area product was 12,723.68 ± 10,665.74 mGy.cm{sup 2}. Among the 78 biopsies, 69 were malignant, 7 were benign and 2 were indeterminate. Diagnostic sensitivity, specificity and accuracy for the diagnosis of malignancies were 97.1 % (67/69), 100 % (7/7) and 97.4 % (74/76), respectively, with a complication rate of 3.85 % (3/78), all of which were small pneumothoraces. CBCT virtual navigation-guided biopsy is a highly accurate and safe procedure for the evaluation of mediastinal lesions. (orig.)

  5. Ultrasound-guided percutaneous biopsy of digestive tract lesions

    International Nuclear Information System (INIS)

    Gil, S.; Martin, I.; Ballesteros, J. M.; Gomez, C.; Marco, S. F.; Fernandez, P.

    1999-01-01

    To present our experience in ultrasound-guided percutaneous biopsy of lesions located in the digestive tract. We performed ultrasound-guided percutaneous biopsy in 14 patients (10 men and 4 women) ranging in age from 7 to 71 years (mean; 519 years). The lesions were located throughout the digestive tract, from the pyriform sinus to the sigmoid colon. The biopsy was carried out with a 5 MHz convex probe equipped with a device to direct the needle. An 18G automatic needle or a 20G Chiba needle was used to obtain specimens for histological study in every case, and additional samples were collected with a 22G needle for cytological examination in 13 of the patients. The ultrasound images corresponded to pseudokidney in 9 cases and extrinsic masses in 5. The diagnosis was obtained from the histological examination in every case (100%) and from cytology in 6 (44.4%), the latter results were less specific. The only complication corresponded to a case of bilioperitoneum. Ultrasound-guided percutaneous biopsy is a suitable technique for the histological diagnosis of those lesions of the digestive tract that are visible in ultrasound images, but that for some reason can not be examined by endoscopic biopsy. (Author) 20 refs

  6. Efficacy of incision and drainage versus percutaneous catheter drainage in treatment of severe acute pancreatitis complicated by pancreatic abscess

    Directory of Open Access Journals (Sweden)

    YANG Feng

    2016-03-01

    Full Text Available ObjectiveTo investigate the clinical features and treatment of severe acute pancreatitis (SAP complicated by pancreatic abscess (PA. MethodsThe clinical data of 17 SAP patients with PA who were admitted to Affiliated Hospital of Luzhou Medical College from January 1, 2005 to August 25, 2015 were analyzed retrospectively. The clinical manifestations, therapeutic methods, and outcome were summarized. ResultsOf all the 17 patients, 12 patients underwent surgical operation, among whom 9 were cured, 1 experienced postoperative intestinal fistula, and 2 experienced recurrence of abscess and underwent the surgery again (1 died of multiple organ failure, and the mean hospital stay was (108.29±52.37 d; 5 patients underwent percutaneous catheter drainage, among whom 4 were cured, and 1 underwent surgical treatment due to inadequate drainage, and the mean hospital stay was (53.03±6.71 d. ConclusionAdequate drainage should be performed once a confirmed diagnosis of PA is made, and appropriate drainage methods should be selected based on the patient′s actual condition. Minimally invasive treatment has a good effect, a short length of hospital stay, and few complications, and holds promise for clinical application.

  7. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    Science.gov (United States)

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  8. [Endoscopic ultrasound guided rendezvous for biliary drainage].

    Science.gov (United States)

    Knudsen, Marie Høxbro; Vilmann, Peter; Hassan, Hazem; Karstensen, John Gésdal

    2015-04-27

    Endoscopic retrograde cholangiography (ERCP) is currently standard treatment for biliary drainage. Endoscopic ultrasound guided rendezvous (EUS-RV) is a novel method to overcome an unsuccessful biliary drainage procedure. Under endoscopic ultrasound guidance a guidewire is passed via a needle from the stomach or duodenum to the common bile duct and from there on to the duodenum enabling ERCP. With a relatively high rate of success EUS-RV should be considered as an alternative to biliary drainage and surgical intervention.

  9. Usefulness of CT-guided automatic needle biopsy of solitary pulmonary nodule smaller than 15 mm

    International Nuclear Information System (INIS)

    Jin, Gong Yong; Lim, Yeong Su

    2004-01-01

    To evaluate the usefulness of the CT-guided percutaneous lung biopsy for the solitary pulmonary nodules smaller than 15 mm in diameter. Between April 2002 and May 2003, we evaluated twenty-five patients (11 men, 14 women, mean ages: 52.5 years) who had solitary pulmonary nodules, which we could not discriminate as being benign or malignant on the CT findings. All the subjects had CT-guided percutaenous cutting needle biopsy (PCNB) performed on them at our institution. A definitive diagnosis of benignity or malignancy was established to retrospectively analyze the patient's records. We evaluated the accuracy, sensitivity, specificity and complications of PCNB for the definitive diagnosis of benignity or malignancy. The sensitivity and specificity of PCNB were determined using the Chi-square test, and the correlations with pneumothorax and emphysema after biopsy were analyzed using Spearman's rank correlation coefficient. In two nodules of the twenty-five nodules, no definitive diagnosis could be established. Of the remaining twenty-three nodules, 7 (30.4%) were malignant and 16 (69.6%) were benign. Twenty (87%) of the twenty-three definitively diagnosed nodules were correctly diagnosed with PCNB. Of the twenty nodules, 6 (30%) were malignant and 14 (70%) were benign. The sensitivity and specificity of the malignant nodules were 85.7% (6/7) and 100% (16/16), respectively. The sensitivity and specificity of the benign nodules were 87.5% (14/16) and 85.7% (6/7), respectively. Post-biopsy complication occurred in nine patients (36%): Hemoptysis (n=4, 16%) and pneumothorax (n=5, 20%). However, there was not a statistical significance between pneumothorax and emphysema after biopsy (r=0.3, p=0.15). When CT-guided percutaneous lung biopsy of the solitary pulmonary nodules smaller than 15 mm in diameter was performed without an on-site cytopathologist, we know that PCNB can yield high diagnostic accuracy and very few complications

  10. Risk Factors for the Need of Surgical Necrosectomy After Percutaneous Catheter Drainage in the Management of Infection Secondary to Necrotizing Pancreatitis.

    Science.gov (United States)

    Ji, Liang; Wang, Gang; Li, Le; Li, Yi-Long; Hu, Ji-Sheng; Zhang, Guang-Quan; Chen, Hong-Ze; Chen, Hua; Kong, Rui; Bai, Xue-Wei; Sun, Bei

    2018-04-01

    This study aimed to assess the need of surgical necrosectomy after percutaneous catheter drainage (PCD) for infected necrotizing pancreatitis. The clinical data of documented/suspected patients who were treated with a step-up approach were extracted and analyzed. Of the 329 patients enrolled, the initial PCD was performed at 12 (interquartile range, 9-15) days since onset and 35.3% were cured by PCD alone. In the pre-PCD model, mean computed tomographic (CT) density of necrotic fluid collection (NFC; P the initial PCD were independent risk factors, and a combination of the previously mentioned 2 factors produced an area under the curve of 0.775. In the post-PCD model, mean CT density of NFC (P = 0.041), MOF (P = 0.002), and serum procalcitonin level (P = 0.035) 3 days after the initial PCD were independent risk factors, and a combination of these previously mentioned factors produced an area under the curve of 0.642. Both mean CT density of NFC and MOF are independent pre- and post-PCD risk factors for the need of necrosectomy after PCD. Post-PCD serum procalcitonin level might be a respondent factor that is correlated with the necessity of necrosectomy.

  11. Recovery from anterograde and retrograde amnesia after percutaneous drainage of a cystic craniopharyngioma.

    Science.gov (United States)

    Ignelzi, R J; Squire, L R

    1976-01-01

    A case is reported of a cystic craniopharyngioma involving the floor and walls of the third ventricle. Pronounced anterograde and retrograde amnesia were documented preoperatively by formal testing. Rapid improvement in both new learning capacity and remote memory occurred after percutaneous twist drill drainage of the cystic portion of the tumour. The relevance of these observations to the amnesic syndrome and its neuropathological basis is discussed. Images PMID:1011035

  12. Percutaneous CT-guided radiofrequency ablation of solitary small renal masses. A single center experience

    Energy Technology Data Exchange (ETDEWEB)

    Pieper, C.C.; Fischer, S.; Strunk, H.; Meyer, C.; Thomas, D.; Willinek, W.A.; Schild, H. [Univ. Bonn (Germany). Dept. of Radiology; Hauser, S. [Univ. Bonn (Germany). Dept. of Urology; Nadal, J. [Univ. Bonn (Germany). Inst. for Medical Biometry; Wilhelm, K. [Johanniter Hospital Bonn (Germany). Dept. of Radiology

    2015-07-15

    To analyze the outcome of patients undergoing percutaneous CT-guided radiofrequency ablation (RFA) of small renal masses (SRM) at a single center during a ten-year time period. Patient records of renal RFAs (07/2003 - 11/2013) were reviewed. Indications were SRM suspicious of malignancy on imaging and one of the following: severe comorbidity; old age; solitary kidney; impaired renal function; patient wish. Biopsy was performed at the time of RFA. Patients were excluded if no follow-up was available. Patient and procedural characteristics were recorded. Survival rates were calculated using the Kaplan-Meier's method and compared with log-rank or cox tests. 38 patients (16 females, mean age 70.0 years [range 52 - 87]) presenting with a solitary SRM were included in the study. Biopsy showed malignancy in 29 patients; 9 had benign tumors. 26 patients suffered from cardiovascular, respiratory or hepatic comorbidities. Technical success (complete ablation on first follow-up) was achieved in 95 % of cases. Two major complications (bowel perforation; hematothorax) occurred. The 3- and 7-year overall survival (OS) [any cause] rates were 73.4 ± 0.8 % and 50.3 ± 1.0 %, respectively (mean follow-up 54.6 months, range 1 - 127). 4 recurrences and 2 metastases were observed. The presence of comorbidities was the only independent predictor of OS. There was no difference in survival between patients with benign and malignant tumors. RFA of SRM is successful in a large percentage of cases with a low complication rate and durable local control. As RFA is typically performed in multimorbid patients, overall survival seems to depend primarily on comorbidities rather than cancer progression.

  13. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    International Nuclear Information System (INIS)

    Oh, Jung Suk; Lee, Hae Giu; Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-01-01

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6–20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6–38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5–14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10–58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites

  14. Pathologic fracture through a unicameral bone cyst of the pelvis: CT-guided percutaneous curettage, biopsy, and bone matrix injection.

    Science.gov (United States)

    Tynan, Jennifer R; Schachar, Norman S; Marshall, Geoffrey B; Gray, Robin R

    2005-02-01

    Unicameral bone cysts of the pelvis are extremely rare. A 19-year old man presented with a pathologic fracture through a pelvic unicameral bone cyst. He was treated with computed tomography-guided percutaneous curettage, biopsy, and demineralized bone matrix injection. Treatment has proven successful in short-term follow-up.

  15. Nursing care for patients receiving perccutaneous biopsy of the pancreas under CT-guidance

    International Nuclear Information System (INIS)

    Li Yongli; Wang Zhenfang

    2010-01-01

    Objective: To discuss the application of nursing care in CT-guided percutaneous biopsy of the pancreas. Methods: The perioperative nursing measures were carried out in 21 patients receiving percutaneous biopsy of the pancreas under CT-guidance. Active, effective and comprehensive nursing procedures were adopted to closely cooperate with the whole process of percutaneous biopsy as far as possible. Results: All the patients could actively cooperate with the physician during the whole process of percutaneous biopsy and the surgery was successfully completed in all patients. The technical success rate with only single puncture was 100%. No obvious complications occurred after the procedure. Conclusion: In order to ensure that the patient will be able to cooperate with the CT-guided percutaneous biopsy of the pancreas, that the operation time can be shortened and that the postoperative complications can be avoided, perioperative nursing care is indispensable. (authors)

  16. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  17. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  18. [Ultrasound guided percutaneous nephrolithotripsy].

    Science.gov (United States)

    Guliev, B G

    2014-01-01

    The study was aimed to the evaluation of the effectiveness and results of ultrasound guided percutaneous nephrolithotripsy (PNL) for the treatment of patients with large stones in renal pelvis. The results of PNL in 138 patients who underwent surgery for kidney stones from 2011 to 2013 were analyzed. Seventy patients (Group 1) underwent surgery with combined ultrasound and radiological guidance, and 68 patients (Group 2)--only with ultrasound guidance. The study included patients with large renal pelvic stones larger than 2.2 cm, requiring the formation of a single laparoscopic approach. Using the comparative analysis, the timing of surgery, the number of intra- and postoperative complications, blood loss and length of stay were evaluated. Percutaneous access was successfully performed in all patients. Postoperative complications (exacerbation of chronic pyelonephritis, gross hematuria) were observed in 14.3% of patients in Group 1 and in 14.7% of patients in Group 2. Bleeding requiring blood transfusion, and injuries of adjacent organs were not registered. Efficacy of PNL in the Group 1 was 95.7%; 3 (4.3%) patients required additional interventions. In Group 2, the effectiveness of PNL was 94.1%, 4 (5.9%) patients additionally underwent extracorporeal lithotripsy. There were no significant differences in the effectiveness of PNL, the volume of blood loss and duration of hospitalization. Ultrasound guided PNL can be performed in large pelvic stones and sufficient expansion of renal cavities, thus reducing radiation exposure of patients and medical staff.

  19. CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection

    International Nuclear Information System (INIS)

    Klass, Darren; Marshall, Tom; Toms, Andoni

    2009-01-01

    Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heated to 90 C for 2 min for two cycles by using a Cosman SMK TC-10 RF electrode. This was preceded by a bolus of room temperature sterile water (10 ml) injected through a 26G curved spinal needle into the exit foramen and adjacent epidural space for neuroprotection. The age of the patient, sex, lesion location, biopsy results and complications were recorded. All the biopsies (n = 7) demonstrated histological features of osteoid osteoma. All the procedures were technically successful. Clinical success was assessed up to 3 years post procedure. There was an 85% clinical success rate (6 of the 7 patients), with recurrence of a lesion at 6 months, necessitating a repeat procedure (successful). CT-guided percutaneous RF ablation of spinal osteoid osteoma preceded by bolus of sterile water, injected through a spinal needle into the exit foramen and adjacent epidural space for neuroprotection, is a safe and effective procedure. (orig.)

  20. Routine Urine Culture at the Time of Percutaneous Urinary Drainage: Does Every Patient Need One?

    International Nuclear Information System (INIS)

    Brody, L.A.; Brown, K.T.; Covey, A.M.; Brown, A.E.; Getrajdman, G.I.

    2006-01-01

    Purpose. To determine the clinical variables associated with bacteriuria in patients undergoing primary percutaneous antegrade urinary drainage procedures in order to predict the utility of routinely obtaining urine cultures at the time of the procedure. Methods. Between October 1995 and March 1998 urine cultures were prospectively obtained in all patients undergoing a primary percutaneous antegrade urinary drainage procedure. One hundred and eighty-seven patients underwent 264 procedures. Results were available in 252 cases. Culture results were correlated with clinical, laboratory, and demographic variables. Anaerobic cultures were not uniformly performed. Results. Urine cultures were positive in 24 of 252 (9.5%) cases. An indwelling or recently removed ipsilateral device (catheter or stent) and a history of previous cystectomy with urinary diversion were significant predictors of a positive culture. Patients without either of these predictors, and without clinical or laboratory evidence of infection, were rarely found to have positive cultures. Conclusion. The likelihood of a positive urine culture can be predicted on the basis of the aforementioned clinical variables. In the absence of these clinical indicators routine urine cultures are neither useful nor cost-effective

  1. Image-guided percutaneous disc sampling: impact of antecedent antibiotics on yield

    International Nuclear Information System (INIS)

    Agarwal, V.; Wo, S.; Lagemann, G.M.; Tsay, J.; Delfyett, W.T.

    2016-01-01

    Aim: To evaluate the effect of antecedent antimicrobial therapy on diagnostic yield from percutaneous image-guided disc-space sampling. Materials and methods: A retrospective review of the electronic health records of all patients who underwent image-guided percutaneous sampling procedures for suspected discitis/osteomyelitis over a 5-year period was performed. One hundred and twenty-four patients were identified. Demographics, medical history, and culture results were recorded as well as duration of presenting symptoms and whether antecedent antibiotic therapy had been administered. Results: Of the 124 patients identified who underwent image-guided percutaneous disc-space sampling, 73 had received antecedent antibiotic treatment compared with 51 who had not. The overall positive culture rate for the present study population was 24% (n=30). The positive culture rate from patients previously on antibiotics was 21% (n=15) compared with 29% (n=15) for patients who had not received prior antibiotic treatment, which is not statistically significant (p=0.26). Eighty-six percent (n=63) of patients who had antecedent antibiotics received treatment for 4 or more days prior to their procedure, whereas 14% (n=10) received treatment for 1–3 days prior to their procedure. The difference in culture positivity rate between these two groups was not statistically significant (p=0.43). Culture results necessitated a change in antibiotic therapy in a third of the patients who had received antecedent antibiotic therapy. Conclusion: Antecedent antibiotic therapy, regardless of duration, did not result in significantly diminished diagnostic yield from percutaneous sampling for suspected discitis/osteomyelitis. The present results suggest that percutaneous biopsy may nonetheless yield positive diagnostic information despite prior antimicrobial therapy. If the diagnostic information may impact choice of therapeutic regimen, percutaneous biopsy should still be considered in cases where

  2. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    Science.gov (United States)

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Percutaneous imaging-guided treatment of hydatid liver cysts: Do long-term results make it a first choice?

    International Nuclear Information System (INIS)

    Kabaalioglu, Adnan; Ceken, Kagan; Alimoglu, Emel; Apaydin, Ali

    2006-01-01

    Aim: To evaluate the long-term results of percutaneous imaging-guided treatment of hydatid liver cysts. Materials and methods: Sixty patients with 77 hydatid liver cysts underwent percutaneous treatment with ultrasonography (US) or computed tomography (CT) guidance. Absolute alcohol and hypertonic saline were used for sclerosing the cysts after aspiration. Prophylactic albendazole treatment was given before and after the procedures. Follow-up US and CT were obtained periodically, and changes in cyst morphology were recorded. Minimum follow-up period for the patients included in this study was 12 months. Serological correlation was also available for a group of patients. The outcome of the procedures were categorized into five groups based on morphological changes observed by imaging. Results: Procedures were regarded as successful in 80% and unsuccessful in 20% of patients. Failures most often occurred with type III cysts; less than half (39%) of the total type III cysts had a successful outcome. On the other hand, all type I cysts ended up with cure. Anaphylaxis, pneumotorax and severe pain interrupting the procedures were also among the reasons of failure. Conclusion: Percutaneous aspiration, injection and reaspiration (PAIR) of types I and II hydatid liver cysts is effective and safe in the long-term. Surgery should no longer be regarded as the first choice treatment in all hydatid liver cysts but should be reserved for type III and certain active type IV cysts

  4. Percutaneous imaging-guided treatment of hydatid liver cysts: Do long-term results make it a first choice?

    Energy Technology Data Exchange (ETDEWEB)

    Kabaalioglu, Adnan [Department of Radiology, Akdeniz University Hospital, Antalya (Turkey)]. E-mail: adnank@akdeniz.edu.tr; Ceken, Kagan [Department of Radiology, Akdeniz University Hospital, Antalya (Turkey); Alimoglu, Emel [Department of Radiology, Akdeniz University Hospital, Antalya (Turkey); Apaydin, Ali [Department of Radiology, Akdeniz University Hospital, Antalya (Turkey)

    2006-07-15

    Aim: To evaluate the long-term results of percutaneous imaging-guided treatment of hydatid liver cysts. Materials and methods: Sixty patients with 77 hydatid liver cysts underwent percutaneous treatment with ultrasonography (US) or computed tomography (CT) guidance. Absolute alcohol and hypertonic saline were used for sclerosing the cysts after aspiration. Prophylactic albendazole treatment was given before and after the procedures. Follow-up US and CT were obtained periodically, and changes in cyst morphology were recorded. Minimum follow-up period for the patients included in this study was 12 months. Serological correlation was also available for a group of patients. The outcome of the procedures were categorized into five groups based on morphological changes observed by imaging. Results: Procedures were regarded as successful in 80% and unsuccessful in 20% of patients. Failures most often occurred with type III cysts; less than half (39%) of the total type III cysts had a successful outcome. On the other hand, all type I cysts ended up with cure. Anaphylaxis, pneumotorax and severe pain interrupting the procedures were also among the reasons of failure. Conclusion: Percutaneous aspiration, injection and reaspiration (PAIR) of types I and II hydatid liver cysts is effective and safe in the long-term. Surgery should no longer be regarded as the first choice treatment in all hydatid liver cysts but should be reserved for type III and certain active type IV cysts.

  5. Endoscopic Ultrasound-Guided Perirectal Abscess Drainage without Drainage Catheter: A Case Series

    Directory of Open Access Journals (Sweden)

    Eun Kwang Choi

    2017-05-01

    Full Text Available A perirectal abscess is a relatively common disease entity that occurs as a postsurgical complication or as a result of various medical conditions. Endoscopic ultrasound (EUS-guided drainage was recently described as a promising alternative treatment. Previous reports have recommended placement of a drainage catheter through the anus for irrigation, which is inconvenient to the patient and carries a risk of accidental dislodgement. We report four cases of perirectal abscess that were successfully treated with only one or two 7 F double pigtail plastic stent placements and without a drainage catheter for irrigation.

  6. CT-guided percutaneous screw fixation plus cementoplasty in the treatment of painful bone metastases with fractures or a high risk of pathological fracture

    Energy Technology Data Exchange (ETDEWEB)

    Pusceddu, Claudio; Ballicu, Nicola; Fele, Rosa Maria; Sotgia, Barbara; Melis, Luca [Oncological Hospital ' ' A. Businco' ' , Regional Referral Center for Oncologic Diseases, Division of Interventional Radiology, Department of Oncological Radiology, Cagliari (Italy); Fancellu, Alessandro [University of Sassari, Department of Clinical and Experimental Medicine, Sassari (Italy)

    2017-04-15

    To evaluate the feasibility and effectiveness of computed tomography (CT)-guided percutaneous screw fixation plus cementoplasty (PSFPC), for either treatment of painful metastatic fractures or prevention of pathological fractures, in patients who are not candidates for surgical stabilization. Twenty-seven patients with 34 metastatic bone lesions underwent CT-guided PSFPC. Bone metastases were located in the vertebral column, femur, and pelvis. The primary end point was the evaluation of feasibility and complications of the procedure, in addition to the length of hospital stay. Pain severity was estimated before treatment and 1 and 6 months after the procedure using the visual analog scale (VAS). Functional outcome was assessed by improved patient walking ability. All sessions were completed and well tolerated. There were no complications related to either incorrect positioning of the screws during bone fixation or leakage of cement. All patients were able to walk within 6 h after the procedure and the average length of hospital stay was 2 days. The mean VAS score decreased from 7.1 (range, 4-9) before treatment to 1.6 (range, 0-6), 1 month after treatment, and to 1.4 (range 0-6) 6 months after treatment. Neither loosening of the screws nor additional bone fractures occurred during a median follow-up of 6 months. Our results suggest that PSFPC might be a safe and effective procedure that allows the stabilization of the fracture and the prevention of pathological fractures with significant pain relief and good recovery of walking ability, although further studies are required to confirm this preliminary experience. (orig.)

  7. Recurrence of primary aldosteronism after percutaneous ethanol injection

    Directory of Open Access Journals (Sweden)

    Fan-Chi Chang

    2012-03-01

    Full Text Available Adrenalectomy is the definite treatment for aldosterone-producing adenoma (APA. Percutaneous ethanol or acetic acid injection with computed tomography (CT guidance has been described as a safe, noninvasive, and effective alternative treatment modality in patients with high surgical risk. We report on a man who was 49 years of age and presented with treatment-resistant hypertension and was later diagnosed with APA. CT-guided percutaneous ethanol injection (PEI was performed for this high surgical risk patient. He had aldosteronism recurrence 4 years after the ethanol injection, so a second PEI was performed. The tumor size was reduced and his blood pressure was normalized. Therefore, we suggest that clinicians should closely check aldosterone to renin ration and potassium level if percutaneous chemical ablation is considered in functioning adrenal adenomas.

  8. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  9. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  10. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  11. Feasibility and effectiveness of image-guided percutaneous biopsy of the urinary bladder.

    Science.gov (United States)

    Butros, Selim Reha; McCarthy, Colin James; Karaosmanoğlu, Ali Devrim; Shenoy-Bhangle, Anuradha S; Arellano, Ronald S

    2015-08-01

    To evaluate the indications, technique, results, and complications of image-guided percutaneous biopsy of the urinary bladder. This retrospective study included 15 patients (10 male, 5 female) who underwent image-guided percutaneous biopsy of the urinary bladder between January 1999 and December 2013. The medical records, imaging studies, procedural details, and long-term follow-up of each patient were reviewed in detail to assess the feasibility of percutaneous bladder biopsy. Ten patients had focal bladder masses and 5 patients had asymmetric or diffuse bladder wall thickening. Eleven patients had either negative or unsatisfactory cystoscopies prior to the biopsy. Percutaneous biopsies were performed under computed tomography guidance in 12 patients and ultrasound in 3 patients. All procedures were technically successful and there were no procedural complications. Malignancy was confirmed in 8 patients, among whom 6 had transitional cell carcinoma, 1 cervical cancer, and 1 prostate cancer metastasis. Seven patients had a benign diagnosis, including 3 that were later confirmed by pathology following surgery and 2 patients with a false-negative result. The overall sensitivity was 80% and accuracy was 87%. Image-guided percutaneous biopsy of the urinary bladder is a safe and technically feasible procedure with a high sensitivity and accuracy rate. Although image-guided bladder biopsy is an uncommon procedure, it should be considered in selected cases when more traditional methods of tissue sampling are either not possible or fail to identify abnormalities detected by cross-sectional imaging.

  12. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D. [Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Born, Christopher T. [Temple University Hospital/Temple Children' s Hospital, Temple Sports Medicine, Marlton, NJ (United States); Grudziak, Jan S. [Children' s Hospital of Pittsburgh, Department of Orthopedic Surgery, Pittsburgh, PA (United States); Towbin, Richard B.

    2004-12-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  13. Closed reduction with CT-guided screw fixation for unstable sacroiliac joint fracture-dislocation

    International Nuclear Information System (INIS)

    Baskin, Kevin M.; Cahill, Ann Marie; Kaye, Robin D.; Born, Christopher T.; Grudziak, Jan S.; Towbin, Richard B.

    2004-01-01

    Unstable posterior pelvic ring fractures and dislocations are uncommon but potentially life-threatening injuries in children. Early definitive management reduces risk of immediate complications as well as chronic pain and gait dysfunction. Conventional operative therapy carries substantial risk of extensive blood loss and iatrogenic neurological and vascular injury. Minimally invasive image-guided intervention may further reduce immediate risk and improve long-term outcome. To describe CT-guided closed reduction and internal fixation (CRIF) and review outcomes of unstable fracture-dislocation of the sacroiliac (SI) joint in children. Between 2000 and 2003, three children (two girls, one boy) age 8-14 years were referred to interventional radiology for treatment of unstable SI joint fracture-dislocation not adequately treated with anterior external fixation alone. The three affected SI joints (two left, one right) were treated in a combined approach by pediatric interventional radiologists and orthopedic surgeons, using a percutaneous approach under CT guidance. Over a threaded guiding pin, 7.3 mm cannulated screws were used to achieve stable reduction of the affected SI joints. One screw was removed after slight (2 mm) migration. No neurovascular or other complications occurred. All patients had satisfactory healing with near-anatomic reduction, although recovery of the youngest was delayed by associated spinal injury. Compared to open surgical alternatives, CRIF under CT guidance reduces operating time, decreases blood loss, and allows early definitive fixation and immediate non-weight-bearing mobilization with a low rate of complication for unstable posterior pelvic ring fractures. In addition, CT-guided placement of the guide pin may allow safer screw positioning and may minimize the total number of screws needed to achieve pelvic stability. (orig.)

  14. Unresectable colorectal liver metastases. Percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT); Nicht resektable kolorektale Lebermetastasen. Perkutane Ablation mittels CT-gesteuerter Hochdosisbrachytherapie (CT-HDBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Lutter, A.; Schnapauff, D.; Denecke, T.; Gebauer, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Hildebrandt, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Oncology; Puhl, G. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of General, Visceral and Transplantation Surgery; Wust, P. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiation Oncology

    2014-06-15

    Purpose: To evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) of unresectable colorectal liver metastases (CRLMs). Materials and Methods: Retrospective analysis of all consecutive patients with unresectable CRLMs treated with CT-HDRBT between January 2008 and November 2012. Treatment was performed by CT-guided catheter placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed after 6 weeks and then every 3 months post-intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: 80 heavily pretreated patients with 179 metastases were available for MRI evaluation for a mean follow-up time of 16.9 months. The mean tumor diameter was 28.5 mm (range: 8 - 107 mm). No major complications were observed. A total of 23 (12.9%) local tumor progressions were observed. Lesions ≥ 4 cm in diameter showed significantly more local progression than smaller lesions (< 4 cm). 50 patients (62.5%) experienced systemic tumor progression. The median TTP was 6 months. 28 (43%) patients died during the follow-up period. The median OS after ablation was 18 months. Conclusion: CT-HDRBT is an effective technique for the treatment of unresectable CRLMs and warrants promising LTC rates compared to thermal ablative techniques. A combination with other local and systemic therapies should be evaluated in patients with lesions > 4 cm in diameter, in which higher progression rates are expected. (orig.)

  15. Acute renal failure and arterial hypertension due to sub capsular hematoma: is percutaneous drainage a feasible treatment?

    DEFF Research Database (Denmark)

    Kobel, Marie Cæcilie; Nielsen, Tommy Kjærgaard; Graumann, Ole

    Percutaneous drainage proved to be successful in managing a renal subcapsular haematoma that was causing acute renal failure and hypertension in a 74-year-old woman. The patient presented with oliguria, nausea and malaise 2 days after a ureteronephroscopic procedure with biopsies of a suspected u...

  16. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  17. Transrectal Drainage of Deep Pelvic Abscesses Using a Combined Transrectal Sonographic and Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Jeong, Kyung Soon; Lee, Eun Jung; Ko, Ji Ho; Joh, Young Duk; Jung, Gyoo Sik

    2005-01-01

    To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39 years) suffering from pelvic pain, fever and leukocytosis were enrolled in this retrospective study. Ultrasound (US) or computed tomography (CT), which was obtained prior to the procedure, showed pelvic fluid collections that were deemed unapproachable by the percutaneous trans abdominal routes. Transrectal drainage of the pelvic abscess was performed under combined transrectal sonographic and fluoroscopic guidance. The causes of the deep pelvic abscess were postoperative complications (n=7), complications associated with radiation (n=3) and chemotherapy (n=1) as well as unknown causes (n=6). A 7.5-MHz end-firing transrectal US probe with a needle biopsy guide attachment was advanced into the rectum. Once the abscess was identified, a needle was advanced via the biopsy guide and the abscess was punctured. Under US guidance, either a 0.018'or 0.035' guide wire was passed through the needle in the abscess. Under fluoroscopic guidance, the tract was dilated to the appropriate diameter with sequential fascial dilators, and a catheter was placed over the guide wire within the abscess. Clinical success of drainage was determined by a combination closure of the cavity on the follow up images and diminished leukocytosis. The technical and clinical success rate, complications, and patient's discomfort were analyzed. Drainage was technically successful in all patients and there were no serious complications. Surgery was eventually performed in two cases due to fistular formation with the rectum and leakage of the anastomosis site. The procedure was well tolerated in all but one patient who complained of discomfort while the catheter was inserted . The catheter did not interfere with defecation and there was no incidence of catheter

  18. The clinical application of percutaneous auto-biopsy of small lung nodular under CT-Guided

    International Nuclear Information System (INIS)

    Zhou Yuanmin; Ye Genxin; Zhang Chenghui; Wang Yu; Chen Wei

    2008-01-01

    Objective: To evaluated the clinical value of technology of petcutaneous auto-biopsy of small lung nodular under CT- Guide. Methods: 44 cases of small single lung nodular were underwent biopsy with 20G auto-biopsy needle under CT guidance. All cases underwent pathological diagnosis. Results: All 44 cases were punctured successfully. 41 cases were succeeded in first puncturation. The success ratio was 93.02%. Other 3 cases needed second puncturation. 39 of 44 cases pathological diagnosis were malignant. Only 1 case could not be diagnosed. 6 patients had lightly pneumatothorax after biopsy. 10 cases had mild pneumonorrhagia after biopsy. 2 of them had haemptysis. All cases had no complication such as infection, needle track implantation. Conclusion: The technology of CT Guidance auto-biopsy of small lung nodular is safe and effective; it has extreme diagnostic ratio and less complication. (authors)

  19. Value of ultrasound in the determination of drainage methods in patients with tuberculous pleural effusion

    International Nuclear Information System (INIS)

    Kang, Eun Young; Suh, Bo Kyoung; Shim, Jae Jeong

    1997-01-01

    To evaluate the utility of ultrasonography (US) as a guide in deciding drainage methods and as a prognostic factor in the prediction of pleural fibrosis, and to compare the effects of drainage methods in patients with tuberculous pleural effusions. In 51 patients with tuberculous pleural effusion, US patterns of pleural effusion were classified according to degree of septa into three groups, as follows : anechoic (n=5), linear septa (n=15), and honeycomb septa (n=31). US-guided drainage methods, including thoracentesis (n=17), percutaneous catheter insertion (n=12), catheter insertion with urokinase instillation (n=22) were employed. Therapeutic effects were evaluated with follow-up chest radiographs after 3 and 6 months. Three months after the procedure, 43 of 51 effusions had drained effectively. US guided drainage failed in eight patients including two of six with linear septated effusion treated with thoracentesis, four of seven with honeycomb septated effusion treated with thoracentesis, and two of six with honeycomb septated effusion treated with catheter drainage. There was no drainage failure in patients with anechoic effusions and in patients with urokinase instillation. Late effects were assessed in 39 patients after 6 months. Follow-up radiographs available in 39 patients demonstrated pleural fibrosis with intercostal space narrowing in 7 patients with honeycomb septated effusion, 3 patients with linear septated effusion, and none of the patients with anechoic effusions. The pattern of septa seen on US could be a useful factor for determining drainage methods and predicting late results in tuberculous pleural effusion. Percutaneous catheter drainage with urokinase instillation was a good drainage modality for patients with septated pleural effusions. Pleural fibrosis is more frequently induced by septated pleural effusion than by anechoic pleural effusion

  20. Value of ultrasound in the determination of drainage methods in patients with tuberculous pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Young; Suh, Bo Kyoung; Shim, Jae Jeong [Korea Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-01-01

    To evaluate the utility of ultrasonography (US) as a guide in deciding drainage methods and as a prognostic factor in the prediction of pleural fibrosis, and to compare the effects of drainage methods in patients with tuberculous pleural effusions. In 51 patients with tuberculous pleural effusion, US patterns of pleural effusion were classified according to degree of septa into three groups, as follows : anechoic (n=5), linear septa (n=15), and honeycomb septa (n=31). US-guided drainage methods, including thoracentesis (n=17), percutaneous catheter insertion (n=12), catheter insertion with urokinase instillation (n=22) were employed. Therapeutic effects were evaluated with follow-up chest radiographs after 3 and 6 months. Three months after the procedure, 43 of 51 effusions had drained effectively. US guided drainage failed in eight patients including two of six with linear septated effusion treated with thoracentesis, four of seven with honeycomb septated effusion treated with thoracentesis, and two of six with honeycomb septated effusion treated with catheter drainage. There was no drainage failure in patients with anechoic effusions and in patients with urokinase instillation. Late effects were assessed in 39 patients after 6 months. Follow-up radiographs available in 39 patients demonstrated pleural fibrosis with intercostal space narrowing in 7 patients with honeycomb septated effusion, 3 patients with linear septated effusion, and none of the patients with anechoic effusions. The pattern of septa seen on US could be a useful factor for determining drainage methods and predicting late results in tuberculous pleural effusion. Percutaneous catheter drainage with urokinase instillation was a good drainage modality for patients with septated pleural effusions. Pleural fibrosis is more frequently induced by septated pleural effusion than by anechoic pleural effusion.

  1. A survey of percutaneous chest drainage practice in French university surgical ICU's.

    Science.gov (United States)

    Remérand, F; Bazin, Y; Gage, J; Laffon, M; Fusciardi, J

    2014-04-01

    Percutaneous chest drainage guidelines were published in 2010 by the British Thoracic Society. On several points (insertion technique, drain size), they seem to differ from French practices. Our objectives were to evaluate practice of pleural drainage in French University surgical intensive care units (ICU's), and to compare it with the British guidelines. National phone survey. Physicians working in 58 ICU's were surveyed first in 2007, and subsequently in 2012. They were read a questionnaire to evaluate the demographic characteristics of their units, their indication for pleural drainage, how they quantified pleural effusion, and their technique for drain insertion. Data from the two surveys were compared to detect an evolution in practice following the publication of the British guidelines. Results are expressed as the mean response. In 2007, pleural drainage indications relied on various respiratory criteria in 91% of cases (versus 95% in 2012) and/or on pleural effusion volume in 71% of cases (versus 59% in 2012). Trocars (Monod or Joly) were used in 68% of the procedures in 2007. In the rest, either blunt dissection, a Pleurocath® or the Seldinger technique was utilized. From 2007 to 2012, the Seldinger technique increased in frequency (10% versus 22%, P=0.005) while Monod trocar usage decreased (41% vs 29%, P=0.012). Ultrasound before pleural effusion drainage became nearly systematic in 2012 (60% vs 86%, Pdrains) for pleural drainage in French ICU's differs significantly from the British guidelines. Copyright © 2014 Société française d’anesthésie et de réanimation (Sfar). Published by Elsevier SAS. All rights reserved.

  2. CT-guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver malignancies; CT-gesteuerte Brachytherapie. Eine neue perkutane Technik zur interstitiellen Ablation von Lebermetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Ricke, J.; Wust, P.; Stohlmann, A.; Beck, A.; Cho, C.H.; Pech, M.; Wieners, G.; Spors, B.; Werk, M.; Rosner, C.; Haenninen, E.L.; Felix, R. [Klinik fuer Strahlenheilkunde, Charite Virchow-Klinikum, Humboldt-Univ. zu Berlin (Germany)

    2004-05-01

    Purpose: to assess safety and efficacy of CT-guided brachytherapy of liver malignancies. Patients and methods: 21 patients with 21 liver malignancies (19 metastases, two primary liver tumors) were treated with interstitial CT-guided brachytherapy applying a {sup 192}Ir source. In all patients, the use of image-guided thermal tumor ablation such as by radiofrequency or laser-induced thermotherapy (LITT) was impeded either by tumor size {>=} 5 cm in seven, adjacent portal or hepatic vein in ten, or adjacent bile duct bifurcation in four patients. Dosimetry was performed using three-dimensional CT data sets acquired after CT-guided positioning of the brachytherapy catheters. Results: the mean tumor diameter was 4.6 cm (2.5-11 cm). The mean minimal tumor dose inside the tumor margin amounted to 17 Gy (12-20 Gy). The proportion of the liver parenchyma exposed to > 5 gy was 18% (5-39%) of total liver parenchyma minus tumor volume. Nausea and vomiting were observed in six patients after brachytherapy (28%). One patient demonstrated obstructive jaundice due to tumor edema after irradiation of a metastasis adjacent to the bile duct bifurcation. We commonly encountered asymptomatic increases of liver enzymes. Local control rates after 6 and 12 months were 87% and 70%, respectively. Conclusion: CT-guided brachytherapy is safe and effective. This technique displays broader indications compared to image-guided thermal ablation by radiofrequency or LITT with respect to tumor size or localization. (orig.) [German] Ziel: Analyse der Sicherheit und Effektivitaet CT-gesteuerter Brachytherapie zur Ablation von Lebermalignomen. Patienten und Methodik: 21 Patienten mit 21 Lebermalignomen (19 Metastasen, zwei primaere Lebermalignome) wurden mit perkutaner, CT-gesteuerter interstitieller Brachytherapie mit {sup 192}Ir behandelt. Alle Patienten wiesen Umstaende auf, die eine bildgefuehrte thermische Ablation mit Radiofrequenz oder laserinduzierter Thermotherapie (LITT) einschraenkten

  3. Ultrasound-guided drainage of subcutaneous abscesses on the trunk is feasible

    DEFF Research Database (Denmark)

    Kjær, Søren; Rud, Bo; Bay-Nielsen, Morten

    2013-01-01

    Subcutaneous trunk abscesses are frequent, and current treatment options generally involve incision. By contrast, the standard care for breast abcesses is ultrasound-guided drainage. The aim of this study was to evaluate the feasibility of ultrasound-guided drainage combined with antibiotics...... in the treatment of subcutaneous abscesses on the trunk....

  4. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    Directory of Open Access Journals (Sweden)

    Chiang Jeng Tyng

    2013-06-01

    Full Text Available Objective To describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and Methods In the period from June 2011 to May 2012, seven computed tomography-guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results In all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible.

  5. Computed tomography-guided percutaneous biopsy of pancreatic masses using pneumodissection

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Bitencourt, Almir Galvao Vieira; Almeida, Maria Fernanda Arruda; Barbosa, Paula Nicole Vieira; Martins, Eduardo Bruno Lobato; Junior, Joao Paulo Kawaoka Matushita; Chojniak, Rubens; Coimbra, Felipe Jose Fernandez

    2013-01-01

    Objective: to describe the technique of computed tomography-guided percutaneous biopsy of pancreatic tumors with pneumodissection. Materials and methods: in the period from June 2011 to May 2012, seven computed tomography guided percutaneous biopsies of pancreatic tumors utilizing pneumodissection were performed in the authors' institution. All the procedures were performed with an automatic biopsy gun and coaxial system with Tru-core needles. The biopsy specimens were histologically assessed. Results: in all the cases the pancreatic mass could not be directly approached by computed tomography without passing through major organs and structures. The injection of air allowed the displacement of adjacent structures and creation of a safe coaxial needle pathway toward the lesion. Biopsy was successfully performed in all the cases, yielding appropriate specimens for pathological analysis. Conclusion: Pneumodissection is a safe, inexpensive and technically easy approach to perform percutaneous biopsy in selected cases where direct access to the pancreatic tumor is not feasible. (author)

  6. Ultrasound-Guided Percutaneous Electrolysis and Eccentric Exercises for Subacromial Pain Syndrome: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    José L. Arias-Buría

    2015-01-01

    Full Text Available Objective. To compare effects of ultrasound- (US- guided percutaneous electrolysis combined with an eccentric exercise program of the rotator cuff muscles in subacromial pain syndrome. Methods. Thirty-six patients were randomized and assigned into US-guided percutaneous electrolysis (n=17 group or exercise (n=19 group. Patients were asked to perform an eccentric exercise program of the rotator cuff muscles twice every day for 4 weeks. Participants assigned to US-guided percutaneous electrolysis group also received the application of galvanic current through acupuncture needle on each session once a week (total 4 sessions. Shoulder pain (NPRS and disability (DASH were assessed at baseline, after 2 sessions, and 1 week after the last session. Results. The ANOVA revealed significant Group∗Time interactions for shoulder pain and disability (all, P<0.01: individuals receiving US-guided percutaneous electrolysis combined with the eccentric exercises experienced greater improvement than those receiving eccentric exercise alone. Conclusions. US-guided percutaneous electrolysis combined with eccentric exercises resulted in small better outcomes at short term compared to when only eccentric exercises were applied in subacromial pain syndrome. The effect was statistically and clinically significant for shoulder pain but below minimal clinical difference for function. Future studies should investigate the long-term effects and potential placebo effect of this intervention.

  7. Prostate biopsy after ano-rectal resection: value of CT-guided trans-gluteal biopsy

    International Nuclear Information System (INIS)

    Cantwell, Colin P.; Hahn, Peter F.; Gervais, Debra A.; Mueller, Peter R.

    2008-01-01

    We describe our single-institutional experience with computed tomography (CT)-guided percutaneous transgluteal biopsy of the prostate in patients in whom transrectal ultrasound-guided biopsy is precluded by prior ano-rectal resection. Between March 1995 and April 2007, 22 patients had 34 prostate biopsies (mean age 68; mean PSA 29 ng/ml; mean follow-up 6.1 years). The charts of patients who had transgluteal biopsy were reviewed for demographic, complications and pathology. Ninety-five percent (21/22) of primary biopsies were diagnostic. Of the 21 diagnostic biopsies, 11 were positive for prostate cancer and ten were definitive benign samples. Seventy-three percent (8/11) of the patients had progressive PSA elevation that mandated 11 further prostate biopsies. Six patients had a second biopsy, one patient had a third and one patient had a fourth biopsy. Among patients who had serial biopsies, 38% (3/8) had prostate cancer. No complications or death occurred. A malignant biopsy was not significantly associated with core number (P = 0.58) or a high PSA level (P 0.15). CT-guided transgluteal biopsy of the prostate is safe and effective. (orig.)

  8. Perlappendiceal inflammatory masses: CT-directed management and clinical outcome in 70 patients

    International Nuclear Information System (INIS)

    Jeffrey, R.B. Jr.; Tolentino, C.S.; Federle, M.P.

    1987-01-01

    The clinical outcome was reviewed in 70 patients with CT evidence of periappendiceal inflammatory masses. Thirty-two patients had either phlegmons or small abscesses (less than 3 cm). These patients were initially treated with antibiotic therapy alone, with resolution of the inflammatory process in 28 of the patients (88%). Twenty-eight patients underwent percutaneous abscess drainage of periappendiceal abscesses that was successful in 26 patients (93%). Although 13 patients (46%) had low-output fistulas communicating with the cecum, 12 of 13 closed with 2 weeks of drainage. Ten patients had early surgical drainage for extensive, poorly defined abscesses. Based on CT, a rational approach can be chosen to reduce morbidity and optimize clinical outcome

  9. The novel echo-guided ProGlide technique during percutaneous transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    Honda, Yohsuke; Araki, Motoharu; Yamawaki, Masahiro; Tokuda, Takahiro; Tsutumi, Masakazu; Mori, Shinsuke; Sakamoto, Yasunari; Kobayashi, Norihiro; Hirano, Keisuke; Ito, Yoshiaki

    2018-04-01

    The aim of this study was to assess clinical benefit of the Echo-guided ProGlide technique in patients undergoing percutaneous transfemoral transcatheter aortic valve implantation (TF-TAVI). The efficacy of the Echo-guided ProGlide technique during percutaneous TF-TAVI was not previously clarified. A total of 121 consecutive patients who underwent percutaneous TF-TAVI at our institution between February 2014 and July 2017 were enrolled in this study. According to the introduction of this novel technique in March 2016, patients were divided into two groups (echo-guided group who underwent TAVI from March 2016 to July 2017, n = 63; not echo-guided group who underwent TAVI from February 2014 to February 2016, n = 58). The incidence of major vascular complications, defined per the Valve Academic Research Consortium-2 criteria, and ProGlide complications including acute femoral artery stenosis or occlusion and bleeding requiring any intervention. The incidence of major vascular complication and ProGlide complication were significantly lower in the echo-guided group than in not echo-guided group (1.6% vs 17.2%, P guided ProGlide technique was independently associated with prevention of ProGlide complications (odds ratio, 0.11; 95% confidential interval, 0.01-0.76; P = 0.03). This novel Echo-guided ProGlide technique was associated with a lower rate of major vascular complications, particularly ProGlide complications during percutaneous TF-TAVI. © 2017, Wiley Periodicals, Inc.

  10. Percutaneous CT-guided sacroiliac joint sampling for infection: aspiration, biopsy, and technique.

    Science.gov (United States)

    Knipp, David; Simeone, F Joseph; Nelson, Sandra B; Huang, Ambrose J; Chang, Connie Y

    2018-04-01

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning.

  11. Percutaneous CT-guided sacroiliac joint sampling for infection. Aspiration, biopsy, and technique

    Energy Technology Data Exchange (ETDEWEB)

    Knipp, David; Simeone, F.J.; Huang, Ambrose J.; Chang, Connie Y. [Massachusetts General Hospital, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Nelson, Sandra B. [Massachusetts General Hospital, Infectious Disease Unit, Department of Medicine, Boston, MA (United States)

    2018-04-15

    To evaluate methods of CT-guided sacroiliac joint sampling in patients with suspected infection. All CT-guided sacroiliac joint sampling procedures for suspected infection were reviewed for sampling type (aspiration, lavage aspiration, biopsy), microbiology results, and clinical and imaging follow-up. The primary gold standard was anatomic pathology. If pathology was not available, then positive blood culture with the same organism as SIJ sampling, imaging and clinical follow-up, or clinical follow-up only were used. Anterior and posterior joint distention was evaluated by MRI within 7 days of the procedure. A total of 34 patients (age 39 ± 20 (range, 6-75) years; 21 F, 13 M) were included. Aspiration samples only were obtained in 13/34 (38%) cases, biopsy samples only in 9/34 (26%) cases, and both samples in 12/34 (35%) cases. There was an overall 54% sensitivity and 86% specificity. For the aspiration samples, sensitivity and specificity were 60 and 81%, respectively, compared to 45 and 90% for the biopsy samples. In cases with both samples, biopsy did not add additional microbial information. Seventeen (17/34, 50%) patients had an MRI. The anterior joint was more distended than the posterior joint in 15/17 (88%) of patients, and this difference was significant (P = 0.0003). All of these 17 patients had an attempted aspiration by a posterior approach; 6/17 (35%) resulted in a successful aspiration. Aspiration of the sacroiliac joint has a higher sensitivity than biopsy and should always be attempted first. MRI may be helpful for procedure planning. (orig.)

  12. Predictors of Percutaneous Catheter Drainage (PCD) after Abdominal Paracentesis Drainage (APD) in Patients with Moderately Severe or Severe Acute Pancreatitis along with Fluid Collections

    Science.gov (United States)

    Liu, Wei-hui; Wang, Tao; Yan, Hong-tao; Chen, Tao; Xu, Chuan; Ye, Ping; Zhang, Ning; Liu, Zheng-cai; Tang, Li-jun

    2015-01-01

    Aims Although we previously demonstrated abdominal paracentesis drainage (APD) preceding percutaneous catheter drainage (PCD) as the central step for treating patients with moderately severe (MSAP) or severe acute pancreatitis (SAP), the predictors leading to PCD after APD have not been studied. Methods Consecutive patients with MSAP or SAP were recruited between June 2011 and June 2013. As a step-up approach, all patients initially received medical management, later underwent ultrasound-guided APD before PCD, if necessary, followed by endoscopic necrosectomy through the path formed by PCD. APD primarily targeted fluid in the abdominal or pelvic cavities, whereas PCD aimed at (peri)pancreatic fluid. Results Of the 92 enrolled patients, 40 were managed with APD alone and 52 received PCD after APD (14 required necrosectomy after initial PCD). The overall mortality was 6.5%. Univariate analysis showed that among the 20 selected parameters, 13 factors significantly affected PCD intervention after APD. Multivariate analysis revealed that infected (peri)pancreatic collections (P = -0.001), maximum extent of necrosis of more than 30% of the pancreas (P = -0.024), size of the largest necrotic peri(pancreatic) collection (P = -0.007), and reduction of (peri)pancreatic fluid collections by collections, a largest necrotic peri(pancreatic) collection of more than 100 ml, and reduction of (peri)pancreatic fluid collections by <50% after APD could effectively predict the need for PCD in the early course of the disease. PMID:25659143

  13. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    International Nuclear Information System (INIS)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan

    1986-01-01

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  14. Persistent high serum bilirubin level after percutaneous transhepatic biliary drainage: analysis of 32 cases

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choi, Byung Ihn; Park, Jae Hyung; Han, Man Chung; Kim, Chu Wan [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1986-12-15

    The aim of percutaneous transhepatic biliary drainage (PTBD) is to decrease serum bilirubin level and promote liver function in patient with biliary tract disease, especially obstruction by malignant disease. But some patients showed persistent high serum bilirubin level or higher than pre-PTBD level. Percutaneous transhepatic biliary drainage was performed in 341 patients of obstructive jaundice for 5 years form July, 1981 to July, 1986 at department of radiology, Seoul National University Hospital. Follow up check of the serum bilirubin level was possible in 188 patients. Among them the authors analysed 32 patients who showed persistent high serum bilirubin level after PTBD. The results were as follows: 1. The male to female ratio was 3.4:1 and the age ranged from 33 to 75. 2. The causes of obstructive jaundice included 30 malignant diseases and 2 benign diseases. Malignant disease were 16 cases of bile duct carcinoma, 7 cases of pancreatic cancer and 7 cases of metastasis from stomach, colon and uterine cervix. Benign disease were 1 case of common hepatic duct stone and 1 case of intrahepatic duct stones. 3. The most common level of obstruction was trifurcation in 17 cases. 4. The most common indication of PTBD was palliative drainage of obstruction secondary to malignant tumor in 28 cases. 5. Change of serum bilirubin level ratio (post-PTBD level/pre-PTBD level) was 1.28, 1.22, 1.38, 1.51 in serial period of 1-3 days, 4-6 days, 1-2 week 2-3 week after PTBD. 6. Causes of persistent high serum bilirubin level after PTBD were 12 cases of partial drainage of intrahepatic bile, 13 cases of hepatic dysfunction including 9 cases of metastatic nodule, 2 cases of biliary cirrhosis, 2 cases of multiple liver abscess, and 7 cases of poor function of catheter including 4 cases of hemobilia, 1 case of multiple intrahepatic stones, pyobilia and intrahepatic Clonorchis sinensis.

  15. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    Energy Technology Data Exchange (ETDEWEB)

    Martel, Jose [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)], E-mail: jmartel@fhalcorcon.es; Bueno, Angel [Departamento de Diagnostico por Imagen, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain); Nieto-Morales, M Luisa [Servicio de Radiologia, Hospital Universitario de Tenerife (Spain); Ortiz, Eduardo J. [Departamento de Cirugia Ortopedica, Fundacion Hospital Alcorcon, Alcorcon, Madrid (Spain)

    2009-09-15

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  16. Osteoid osteoma of the spine: CT-guided monopolar radiofrequency ablation

    International Nuclear Information System (INIS)

    Martel, Jose; Bueno, Angel; Nieto-Morales, M Luisa; Ortiz, Eduardo J.

    2009-01-01

    CT-guided percutaneous radiofrequency ablation and laser photocoagulation have become the methods of choice for the treatment of all osteoid osteomas except those in contact with neural structures. We report 10 patients with spinal osteoid osteoma adjacent to the neural elements treated with 12 sessions of CT-guided monopolar radiofrequency ablation. The size range of the lesion was 3-14 mm (mean, 7.5 mm) and the distance between the nidus and the adjacent spinal cord or nerve root was 2-12 mm (mean, 5 mm). No intact cortex between the tumor and the spinal cord or nerve roots constituted an exclusion criterion because of a higher risk of undesirable neurotoxic effects. Patients were under general anesthesia. After location of the lesion, a 11G-bone biopsy was introduced into the nidus. The radiofrequency electrode was inserted through the biopsy needle and heated at 90 deg. C for 4 min. Primary success was obtained in eight patients. At follow-up (mean, 19.5 months; range, 6-24 months), pain persisted in two patients after 2 months. Both of them were re-treated. All patients are currently pain-free and complications were not detected. In our opinion, radiofrequency ablation can also be considered the treatment of choice for spinal osteoid osteoma.

  17. Clinical study of ultrasound-guided percutaneous radiofrequency ablation for primary hepatic carcinoma adjacent to the diaphragm

    Directory of Open Access Journals (Sweden)

    LI Meng

    2015-04-01

    Full Text Available ObjectiveTo investigate the safety and efficacy of ultrasound (US-guided percutaneous radiofrequency ablation (RFA for primary hepatic carcinoma adjacent to the diaphragm. MethodsThis study included 277 patients with 362 lesions of primary hepatic carcinoma managed with US-guided percutaneous RFA in 302 Hospital of PLA from January 2011 to October 2014. Sixty-six patients with 71 hepatocellular carcinomas (HCCs located less than 5 mm from the diaphragm were in study group, and 95 patients with 114 HCCs located more than 10 mm from the hepatic surface were in control group. The patients′ symptoms and complications were observed after the therapy. The complete ablation rate, local tumor progression rate, and complication rate were compared between the two groups. Comparison of continuous data between the two groups was made by independent-samples t test, while comparison of categorical data was made by chi-square test. ResultsAt one month after operation, 65 (91.5% of 71 tumors in the study group and 107 (93.9% of 114 tumors in the control group achieved complete ablation, according to contrast-enhanced CT and MRI, and there was no significant difference between the two groups (χ2=0.36, P=0.55. The postoperative follow-up showed that the local tumor progression rates in the study group and control group were 16.9% and 13.2%, respectively, without significant difference between the two groups (χ2=0.49, P=0.48. In the study group, 22 patients developed adverse reactions, versus 37 patients in the control group (χ2=2.60, P=0.11. ConclusionUS-guided percutaneous RFA is a safe and effective means for the treatment of primary hepatic carcinoma adjacent to the diaphragm.

  18. Comparative study of CT and MR guided cryoablation for hepatic tumors

    International Nuclear Information System (INIS)

    Wu Bin; Xiao Yueyong; Zhang Xiao; Li Hongjun; Li Jie; Yu Da

    2010-01-01

    Objective: To compare CT and MR imaging in guiding and monitor/ng cryoablation of hepatic tumors. Methods: A total of 131 lesions in 121 patients with malignant tumors of liver were treated with imaging-guided percutaneous cryotherapy. There were 73 males and 48 females, mean age 60 years. Of the 121 patients, 61 patients had cryoablation under CT guidance and 60 patients under the guidance of MRI. CT-guidance was performed with the Philips big-bore CT in spiral mode, with 5 mm slice thickness. The MR guidance was performed with GE 0.35 T scanner assisted with infrared navigator (Xinaomdt), and both fast gradient echo sequence and fast spin-echo sequence were used. The cryoablation system is a magnetic resonance compatible system (Galil, Israel), equipped with 17 G cryoprobes that are 1.47 mm in outside diameter. A combination of multiple cryo-probes and conformal cryoablation were adopted in accordance with the location, the shape and the adjacent structure of each lesion. Each cryoablation included two freezing-thawing cycles. Scanning was performed intermittently during the operation to monitor the degree of ablation. The mean scanning time, the lesion depiction and ablation process monitoring, the efficacies of lesion ablation, complications,and survival time were analyzed with χ 2 test. Results: The mean scanning time was (5.6±1.8) min for CT and (22.0±2.6) min for MR. CT provided a good depiction of the lesion and the ribs which were poorly displayed on MR images. The metal probe could create artifacts on the CT images and it was difficult for CT to show the formation of ice ball of the lesion formed after embolization with lipiodol. MR was superior to CT in displaying, guiding and monitoring of ablation of lesions near such special regions as the diaphragm dome, the hepatic hilum, and the gallbladder. MR was not affected by high-density embolization material and the metal probes, and thus was superior to CT in depicting the lesion, and monitoring the

  19. CT‑guided percutaneous transthoracic lung biopsy: First experience ...

    African Journals Online (AJOL)

    Percutaneous lung biopsy had been described in the nineteenth century by Leyden, but image- guided needle chest biopsy only gained widespread acceptance in the 1970s. Currently, tissue sampling of a thoracic lesion is indicated when the diagnosis cannot be obtained by the non-invasive techniques and cytological ...

  20. Lymphocele Mimicking a Pancreatic Pseudocyst: Imaging Characteristics and Percutaneous Management

    International Nuclear Information System (INIS)

    Chen, Y.-H.; Sonnenberg, Eric van; Urman, Richard; Silverman, Stuart G.

    2003-01-01

    Lymphocele can be a difficult diagnosis to establish and may be confused for other abdominal fluid collections.Conversely, pancreatic pseudocysts may occur inadvertently from upper abdominal surgery and must be included in the differential diagnosis of virtually all peripancreatic fluid collections. We report the unusual occurrence of an unsuspected postoperative peripancreatic lymphocelethat was thought to be a pancreatic pseudocyst. In retrospect, CT findings were evident and diagnostic. The lymphocele responded well to percutaneous drainage

  1. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  2. Percutaneous Cryoablation of Small Hepatocellular Carcinoma with US Guidance and CT Monitoring: Initial Experience

    International Nuclear Information System (INIS)

    Orlacchio, Antonio; Bazzocchi, Gabriele; Pastorelli, Daniela; Bolacchi, Francesca; Angelico, Mario; Almerighi, Cristiana; Masala, Salvatore; Simonetti, Giovanni

    2008-01-01

    The purpose of this study was to retrospectively determine the safety and effectiveness of percutaneous cryoablation, monitored with computed tomography (CT) and ultrasonographic (US) guidance, for the treatment of hepatocellular carcinoma (HCC). Four patients with small HCCs underwent one percutaneous cryoablation treatment session monitored with CT and US guidance. All patients underwent pretreatment blood chemistry testing and imaging evaluation. We treated lesions with simultaneous insertion of multiple 17-G cryoprobes (two or three) and defined technical success when the extension of a visible iceball was beyond 5 mm from the tumor margin. Intralesional enhancement or tumoral size increase was defined as local progression compared with that on images obtained immediately after ablation. We evaluated complications and follow-up (at 1, 3, and 6 months). All patients survived without short- or long-term complications. Cryoablation was technically successful in all patients at the end of the procedure. During follow-up two patients developed disease recurrence. One patient developed local tumor progression on the margin of the lesion; the other, a new HCC. In the case of local tumor progression a new elevation of α-fetoprotein (αFP) levels occurred at first follow-up control. In the other case levels of αFP remained stable during the first 3 months after the procedure, then demonstrated a progressive increase in αFP levels beginning at the fourth month, without tumor evidence during CT control at 3 months. We conclude that percutaneous cryotherapy with US guidance and CT monitoring is a feasible, safe, and effective for treatment of HCC. If local ablative procedures of hepatic lesions are to be performed, percutaneous cryoablation, not laparotomic, should be discussed as an alternative therapeutic measure. Longer follow-up should provide proof of the effectiveness of this technique

  3. Sono-Guided Percutaneous Automated Gun Biopsy in Pediatric Renal Disease

    International Nuclear Information System (INIS)

    Kim, Jong Chul

    1996-01-01

    To evaluate whether sono-guided percutaneous automated gun biopsy is also useful in pediatricpatients with renal diseases. In the prone position of twenty pediatric patients with renal parenchymal diseases, percutaneous biopsy was done through lateral aspect of the lower pole of left kidney with automated biopsy gun under the guidance of ultrasonography. The biopsy needle was either of 18 or 20 gauge. The obtained core of renal tissue was examined with light, immunofluorescent or electron microscope by the renal pathologist. In 18 among 20 patients, adequate renal tissue core sufficient to be pathologically diagnosed was obtained. The histologic findings were as follows : IG A nephropathy (n = 2), lupus nephritis (n =2), minimal change glomerulonephritis (n = 5), membranoproliferative glomerulonephritis (n = 3), mesangialproliferative glomeru-lonephritis (n = 1), diffuse proliferative glomerulonephritis (n = 3), focalglomerulo-sclerosis (n = 1), membranous glomerulopathy (n = 1). No significant complications occurred during or after the biopsy. Sono-guided percutaneous renal biopsy using automated biopsy gun is also useful todiagnose renal parenchymal diseases without significant complications in pediatric patients

  4. Percutaneous Transhepatic Catheterization of the Portal Vein: A Combined CT- and Fluoroscopy-Guided Technique

    International Nuclear Information System (INIS)

    Weimar, Bernd; Rauber, Klaus; Brendel, Mathias D.; Bretzel, Reinhard G.; Rau, Wigbert S.

    1999-01-01

    Combined CT- and fluoroscopy-guided transhepatic portal vein catheterization was performed in 44 patients selected for pancreatic islet cell transplantation. The method allowed catheterization with a single puncture attempt in 39 patients. In four patients two attempts and in one patient four attempts were necessary. One minor hematoma of the liver capsule occurred that required no further treatment. Compared with other methods the average number of puncture attempts was reduced

  5. Amoebic liver abscess: Drained by ultrasound guided percutaneous ...

    African Journals Online (AJOL)

    Summary: Amoebic Liver Abscess in a 20-month-old child: A case of amoebic liver abscess in a Nigerian child is presented. Management consisted of 10days course of Metronidazole and 5days course of Tinidazole without improvement. This was followed by four sessions of ultrasound guided percutaneous needle ...

  6. Sonography-guided percutaneous microwave ablation of intrahepatic primary cholangiocarcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yu Mingan [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Liang Ping, E-mail: Liangping301@hotmail.com [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China); Yu Xiaoling; Cheng Zhigang; Han Zhiyu; Liu Fangyi; Yu Jie [Department of Interventional Ultrasound, Chinese PLA General Hospital, 28 Fuxing Road, Beijing, 100853 (China)

    2011-11-15

    Objective: To evaluate the efficacy and safety of sonography-guided percutaneous microwave ablation of intrahepatic primary cholangiocarcinoma. Materials and methods: From May 2006 to March 2010, 15 patients (11 men, 4 women; mean age, 57.4 years) with 24 histologically proven intrahepatic primary cholangiocarcinoma lesions (mean tumor size, 3.2 {+-} 1.9 cm; range, 1.3-9.9 cm) were treated with microwave ablation. Results: Thirty-eight sessions were performed for 24 nodules in 15 patients. The follow-up period was 4-31 months (mean, 12.8 {+-} 8.0 months). The ablation success rate, the technique effectiveness rate, and the local tumor progression rate were 91.7% (22/24), 87.5% (21/24), and 25% (6/24) respectively according to the results of follow-up. The cumulative overall 6, 12, 24 month survival rates were 78.8%, 60.0%, and 60.0%, respectively. Major complication occurred including liver abscess in two patients (13.3%) and needle seeding in one patient (6.7%). Both complications were cured satisfied with antibiotic treatment combined to catheter drainage for abscess and resection for needle seeding. The minor complications and side effects were experienced by most patients which subsided with supportive treatment. Conclusion: Microwave ablation can be used as a safe and effective technique to treat intrahepatic primary cholangiocarcinoma.

  7. Percutaneous CT-guided high frequency induced thermotherapy as a treatment hepatocellular carcinoma and hepatic metastatic lesions

    International Nuclear Information System (INIS)

    Lu Ligong; Luo Pengfei; Chen Xiaoming

    2004-01-01

    Objective: To analyze the efficacy, side effects and complications of percutaneous high frequency induced thermotherapy (HiTT) performed under CT guidance involving 36 patients with hepatocellular carcinomas (HCC) and hepatic metastatic lesions. Methods: HiTT was performed in treatment of 36 patients (24 men and 12 women) with 42 hepatocellular carcinoma and hepatic metastatic carcinoma (six patient out of 36 had two nidi). The diameter of the tumors ranged from 1.6 to 7.8 cm (mean, 3.2 cm). The efficacy of HiTT was evaluated with triphasic spiral CT performed 1 month after the procedure. Results: The post-treatment CT scan showed complete necrosis in 33 nidi (78%) out of 42 nidi of hepatocellular carcinoma and hepatic metastatic carcinoma in 30 patients out of 36. Complete necrosis was obtained in 18 (95%) of 19 tumors no larger than 3 cm in diameter, 13 (72%) of 18 tumors between 3.0 and 5.0 cm in diameter. Eleven tumors showed incomplete necrosis. In our study, none of the patients experienced severe complications. All the patients are alive in the follow-up ranging from 2 to 12 months (mean, 7 months). Conclusion: Our research suggests that HiTT can be a safe and effective treatment of hepatocellular carcinomas and hepatic metastatic carcinoma when the lesion is no larger than 3 cm. The treatment is relatively effective for hepatocellular carcinoma between 3 and 5 cm in size. (authors)

  8. Percutaneous management of tumoral biliary obstruction in children

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan [Hacettepe School of Medicine, Department of Radiology, Sihhiye, Ankara (Turkey); Ekinci, Saniye [Hacettepe School of Medicine, Department of Paediatric Surgery, Sihhiye, Ankara (Turkey); Akcoren, Zuhal [Hacettepe School of Medicine, Department of Paediatric Pathology, Sihhiye, Ankara (Turkey); Kutluk, Tezer [Hacettepe School of Medicine, Department of Paediatric Oncology, Sihhiye, Ankara (Turkey)

    2007-10-15

    There is limited experience of percutaneous biliary interventions in children although they are safe and effective procedures. To evaluate the efficacy and safety of percutaneous management of tumoral biliary obstruction in children. Percutaneous biliary interventions were performed in eight children (six boys, two girls) with a mean age of 10.5 years (range 4-17 years). The interventions included percutaneous biliary drainage (five patients), percutaneous biliary drainage and placement of a self-expanding metallic stent (two patients), and percutaneous cholecystostomy (one patient). All patients had signs of obstructive jaundice and two had cholangitis. All procedures were successful. No procedure-related mortality was observed. Bilirubin levels returned to normal in four of the eight patients. Findings of cholangitis resolved in the two affected patients after the procedure and antibiotic treatment. Two patients underwent surgery after percutaneous biliary drainage procedures. A self-expanding metallic stent was placed in two patients with malignancy and the stents remained patent until death. Percutaneous biliary interventions can be performed safely for the management of tumoral biliary obstruction in children. (orig.)

  9. Percutaneous management of tumoral biliary obstruction in children

    International Nuclear Information System (INIS)

    Akinci, Devrim; Gumus, Burcak; Ozkan, Orhan S.; Ozmen, Mustafa N.; Akhan, Okan; Ekinci, Saniye; Akcoren, Zuhal; Kutluk, Tezer

    2007-01-01

    There is limited experience of percutaneous biliary interventions in children although they are safe and effective procedures. To evaluate the efficacy and safety of percutaneous management of tumoral biliary obstruction in children. Percutaneous biliary interventions were performed in eight children (six boys, two girls) with a mean age of 10.5 years (range 4-17 years). The interventions included percutaneous biliary drainage (five patients), percutaneous biliary drainage and placement of a self-expanding metallic stent (two patients), and percutaneous cholecystostomy (one patient). All patients had signs of obstructive jaundice and two had cholangitis. All procedures were successful. No procedure-related mortality was observed. Bilirubin levels returned to normal in four of the eight patients. Findings of cholangitis resolved in the two affected patients after the procedure and antibiotic treatment. Two patients underwent surgery after percutaneous biliary drainage procedures. A self-expanding metallic stent was placed in two patients with malignancy and the stents remained patent until death. Percutaneous biliary interventions can be performed safely for the management of tumoral biliary obstruction in children. (orig.)

  10. Percutaneous nephrolithotomy in ectopically located kidneys and in patients with musculoskeletal deformities.

    Science.gov (United States)

    Srivastava, A; Gupta, P; Chaturvedi, S; Singh, P; Kapoor, R; Dubey, D; Kumar, A

    2010-01-01

    To assess the feasibility, safety and results of percutaneous nephrolithotomy (PNL) in ectopically located kidneys and in patients with musculoskeletal deformities. Thirteen such patients underwent PNL between June 2005 and May 2008. Mean stone size was 27.4 mm (16-37 mm). Six patients had severe kyphoscoliosis, 2 patients each had achondroplasia, cross-fused ectopia and pelvic ectopic kidney, and 1 patient had thoracic kidney. All had a preoperative CT scan of the abdomen. Preoperative ultrasound- or CT-guided percutaneous nephrostomy (PCN) was done in 10 patients. Three patients underwent laparoscopic-assisted PNL. All underwent standard PNL. The stone-free rate, complication rate and need for secondary intervention were evaluated. PNL was successfully completed in all. A second ultrasound-guided intraoperative puncture was required in 2 patients. Re-look PNL was required in 1 patient and the same patient later required shock wave lithotripsy for complete stone clearance. The remaining 12 patients (92.3%) were rendered stone-free in a single sitting. PNL is a feasible and effective modality in anomalous kidneys. Preoperative planning with CT and image-guided PCN is helpful in these situations. Laparoscopic-assisted PNL can be safely performed in patients where access to a renal collecting system by fluoroscopy or image-guided assistance (ultrasound or CT scan) is not possible. Copyright (c) 2010 S. Karger AG, Basel.

  11. CT assessment of anastomotic bowel leak

    International Nuclear Information System (INIS)

    Power, N.; Atri, M.; Ryan, S.; Haddad, R.; Smith, A.

    2007-01-01

    Aim: To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Subjects and methods: Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10 ± 5.9 SD) for the anastomotic group and 3-40 days (mean 14 ± 11 SD) for the control group (p = 0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. Results: The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4 ± 6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only peri-anastomotic loculated fluid containing air was more frequently seen in the CIAL group as opposed to the no leak group (p = 0.04). There was no intestinal contrast leakage in this cohort. Free air was present up to 9 days and loculated air up to 26 days without CIAL. Conclusion: Most postoperative CT features overlap between patients with and without CIAL. The only feature seen statistically more frequently with CIAL is peri-anastomotic loculated fluid containing air

  12. CT assessment of anastomotic bowel leak

    Energy Technology Data Exchange (ETDEWEB)

    Power, N. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Atri, M. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)]. E-mail: mostafa.atri@sw.ca; Ryan, S. [Department of Radiology, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Haddad, R. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada); Smith, A. [Department of Surgery, Sunnybrook Hospital, Toronto, Ontario M4N 3M5 (Canada)

    2007-01-15

    Aim: To evaluate the predictors of clinically important gastrointestinal anastomotic leaks using multidetector computed tomography (CT). Subjects and methods: Ninety-nine patients, 73 with clinical suspicion of anastomotic bowel leak and 26 non-bowel surgery controls underwent CT to investigate postoperative sepsis. Fifty patients had undergone large bowel and 23 small bowel anastomoses. The time interval from surgery was 3-30 days (mean 10 {+-} 5.9 SD) for the anastomotic group and 3-40 days (mean 14 {+-} 11 SD) for the control group (p = 0.3). Two radiologists blinded to the final results reviewed the CT examinations in consensus and recorded the presence of peri-anastomotic air, fluid or combination of the two; distant loculated fluid or combination of fluid and air; free air or fluid; and intestinal contrast leak. Final diagnosis of clinically important anastomotic leak (CIAL) was confirmed at surgery or by chart review of predetermined clinical and laboratory criteria. Results: The prevalence of CIAL in the group undergoing CT was 31.5% (23/73). The CT examinations with documented leak were performed 5-28 (mean; 11.4 {+-} 6 SD) days after surgery. Nine patients required repeat operation, 10 percutaneous abscess drainage, two percutaneous drainage followed by surgery, and two prolonged antibiotic treatment and total parenteral nutrition (TPN). Of the CT features examined, only peri-anastomotic loculated fluid containing air was more frequently seen in the CIAL group as opposed to the no leak group (p = 0.04). There was no intestinal contrast leakage in this cohort. Free air was present up to 9 days and loculated air up to 26 days without CIAL. Conclusion: Most postoperative CT features overlap between patients with and without CIAL. The only feature seen statistically more frequently with CIAL is peri-anastomotic loculated fluid containing air.

  13. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  14. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  15. Percutaneous computed tomography-guided ethanol injection in aldosterone-producing adrenocortical adenoma

    International Nuclear Information System (INIS)

    Rossi, R.; Savastano, S.; Tommaselli, A.P.

    1995-01-01

    The feasibility, safety and effectiveness of percutaneous computed tomography-guided ethanol injection (PEI-CT) was investigated in a patient affected by aldosterone-producing adenoma (APA). A 42-year-old male patient with typical features of hyperaldosteronism presented a solitary left adrenal adenoma measuring 2 cm, with a normal contralateral gland, evidenced by both CT scan and adrenal [ 75 Se-19]-nor-cholesterol scintigraphy. After normalization of potassium plasma levels, 4 ml of sterile 95% ethanol with 0.5 ml of 80% iothalamate sodium was injected. The procedure was completed in about 30 min. No severe pain or local complication was noted. Five hour after PEI, a fourfold and a twofold increase in aldosterone and cortisol plasma levels were observed, respectively. After 11 days on a normal sodium and potassium diet, normal potassium plasma levels and reduced aldosterone plasma levels were present, with reappearance of an aldosterone postural response. Plasma renin activity and aldosterone plasma levels normalized 1 month later, with reappearance also of a plasma renin activity postural response and maintenance of normal potassium plasma levels on a high sodium and normal potassium diet. The patient has remained hypertensive, although lower antihypertensive drug dosages have been employed. After 17 months, normal biochemical, hormonal and morphological findings were present. The authors suggested PEI-CT as a further alternative approach to surgery in the management of carefully selected patients with APA. 15 refs., 2 figs., 1 tab

  16. Percutaneous Image-guided radiofrequency ablation of tumors in inoperable patients - immediate complications and overall safety

    Directory of Open Access Journals (Sweden)

    Anubha Sahay

    2016-01-01

    Conclusions: Percutaneous image-guided RFA is an option in patients where most other tumor management modalities have been exhausted or rejected. RFA may not be free from side effects such as postablation syndrome, pain, and there may be other serious complications such as bleeding, but based on our observations, percutaneous image-guided RFA of tumors is a safe palliative and therapeutic treatment option.

  17. Discussion of percutanous nephrostomy technique with prevention and treatment of complications

    International Nuclear Information System (INIS)

    Zhang Zefu; Liang Huiming; Zheng Chuansheng; Wu Hanpin; Zhou Guofeng

    2008-01-01

    Objective: To analyze the complications and treatment technique of percutaneous nephrostomy. Methods: 247 hydronephrosis eases treated with percutaneous nephrostomy guided by ultrosound and fluroseopy flora Januray 2007 to April 2008 were evaluated retrospectively and the causes of complications and suitable treatments were analyzed. Results: The successful rate of percutaneous nephrostomy in 247 hydronephrotic cases reached 100%. In all cases, 4 cases occurred with severe complications (1.6%) including 3 massive hemorrhage and 1 septic shock during the operation. The minor complications (25 cases, 10% ) were hematuria, urinary tract infection, local haematoma, perirenal haematoma, detachment of drainage tube with obstruction and exodus, internal double-J catheter displacement and obstruction, etc. Conclusion: The operative safety and treatment efficacy of percutaneous nephrostomy could be achieved through skillful management and comprehensive preoperative evaluation of the risk factors for the complications. (authors)

  18. Percutaneous biliary drainage effectively lowers serum bilirubin to permit chemotherapy treatment.

    Science.gov (United States)

    Levy, Jennifer L; Sudheendra, Deepak; Dagli, Mandeep; Mondschein, Jeffrey I; Stavropoulos, S William; Shlansky-Goldberg, Richard D; Trerotola, Scott O; Teitelbaum, Ursina; Mick, Rosemarie; Soulen, Michael C

    2016-02-01

    For digestive tract cancers, the bilirubin threshold for administration of systemic chemotherapy can be 5 or 2 mg/dL (85.5 or 34.2 μmol/L) depending upon the regimen. We examined the ability of percutaneous biliary drainage (PBD) in patients with malignant biliary obstruction to achieve these clinically relevant endpoints. 106 consecutive patients with malignant biliary obstruction and a baseline serum bilirubin >2 mg/dL underwent PBD. Time to achieve a bilirubin of 5 mg/dL (85.5 μmol/L), 2 mg/dL (34.2 μmol/L), and survival was estimated by Kaplan-Meier analysis. Potential technical and clinical prognostic factors were subjected to univariate and multivariate analysis. Categorical variables were analyzed by the log rank test. Hazard ratios were calculated for continuous variables. Median survival was 100 days (range 1-3771 days). Among 88 patients with a pre-drainage bilirubin >5 mg/dL, 62% achieved a serum bilirubin ≤5 mg/dL within 30 days and 84% within 60 days, median 21 days. Among 106 patients with a pre-drainage bilirubin >2 mg/dL, 37% achieved a serum bilirubin ≤2 mg/dL by 30 days and 70% within 60 days, median 43 days. None of the technical or clinical factors evaluated, including pre-drainage bilirubin, were significant predictors of time to achieve a bilirubin ≤2 mg/dL (p = 0.51). Size and type of biliary device were the only technical variables found to affect time to bilirubin of 5 mg/dL (p = 0.016). PBD of malignant obstruction achieves clinically relevant reduction in serum bilirubin in the majority of patients within 1-2 months, irrespective of the pre-drainage serum bilirubin, sufficient to allow administration of systemic chemotherapy. However, the decision to undergo this procedure for this indication alone must be considered in the context of patients' prognosis and treatment goals.

  19. Percutaneous drainage and stenting for palliation of malignant bile duct obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Delden, Otto M. van; Lameris, Johan S. [Academic Medical Center of the University of Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2008-03-15

    Percutaneous biliary drainage and stenting (PTBD) for palliation of malignant obstructive jaundice has evolved to a safe and effective technique. PTBD is equally effective for treatment of distal and proximal bile obstruction. Metal self-expandable stents have proved superior to plastic stents and should therefore be used. Technical success is >90% en clinical success is >75% in all major series. There are a considerable number of complications, but most can be treated conservatively and procedure-related mortality is <2% in most series. Thirty-day mortality after PTBD is >10% in many series, but this is largely due to the underlying disease. About 10-30% of patients will have recurrent jaundice at some point in their disease after PTBD and require re-intervention. (orig.)

  20. Diagnosis and treatment of arteriobiliary hemorrhage occurring after percutaneous biliary drainage

    International Nuclear Information System (INIS)

    Eversman, W.G.; Welch, T.J.; May, G.R.; Bender, C.E.; Williams, H.J. Jr.

    1986-01-01

    Hemorrhage due to arteriobiliary communication occurred in 15 of 500 patients after percutaneous biliary drainage (PBD). Hemorrhage produced a distinct clinical syndrome and occurred sooner after PBD in patients with benign disease (eight patients, mean of 1.5 weeks) than in patients with neoplastic obstruction (seven patients, mean of 11.5 weeks). In eight patients the author identified the bleeding vessel by contrast agent injection into the transhepatic tract, and in four we were able to embolize this vessel via the transhepatic tract. Eleven patients underwent hepatic arteriography, which identified contrast agent extravasation or arterial abnormality. Angiographic embolization was possible in eight of the 11. Embolization via the transhepatic tube tract should be attempted first, with angiographic embolization as a backup

  1. Unique usage of a partially covered metal stent for drainage of a pancreatic pseudocyst via endosonography-guided transcystgastrostomy.

    Science.gov (United States)

    Nici, Anthony J; Hussain, Syed A; Kim, Sang H; Mehta, Preeti

    2012-05-01

    Pancreatic pseudocysts are frequent complications of pancreatitis episodes. The current therapeutic modalities for drainage of pancreatic pseudocysts include surgical, percutaneous, and endoscopic drainage modalities. Endosonography-assisted endoscopic drainage of these pseudocysts with the placement of multiple plastic or fully covered self-expanding biliary metal stents is becoming more commonly carried out. The present case report discusses the unique and successful drainage of a pancreatic pseudocyst with the placement of a partially covered self-expanding metal stent. © 2012 The Authors. Digestive Endoscopy © 2012 Japan Gastroenterological Endoscopy Society.

  2. CT-guided {sup 125}I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei, E-mail: gaof@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Li, Chuanxing, E-mail: licx@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Gu, Yangkui, E-mail: guyk@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Huang, Jinhua, E-mail: huangjh@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Wu, Peihong, E-mail: vivian-link@163.com [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China)

    2013-02-15

    Objectives: To retrospectively evaluate effectiveness and safety of CT-guided {sup 125}I brachytherapy in 16 patients with mediastinal metastatic lymph nodes recurrence from esophageal carcinoma. Materials and methods: Sixteen metastatic lymph nodes in 16 patients were percutaneously treated in 19 {sup 125}I brachytherapy sessions. Each metastatic lymph node was treated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT or positron emission tomographic (PET) scans were reviewed and the treatment's effectiveness was evaluated. Results: Months are counted from the first time of {sup 125}I brachytherapy and the median duration of follow-up was 11 months (range, 5–16 months). The local control rates after 3, 6, 10 and 15 months were 75.0, 50.0, 42.9 and 33.3% respectively. At the time of writing, four patients are alive without evidence of recurrence at 16, 9, 16 and 9 months. The 4 patients presented good control of local tumor and no systemic recurrence, and survived throughout the follow-up period. The other 12 patients died of multiple hematogenous metastases 5–15 months after brachytherapy. A small amount of local hematoma occurred in 2 patients that involved applicator insertion through the lung. Two patients presented pneumothorax with pulmonary compression of 30 and 40% after the procedure and recovered after drainage. One patient had minor displacement of radioactive seeds. Severe complications such as massive bleeding and radiation pneumonitis did not occur. Conclusion: {sup 125}I radioactive seed implantation is effective and may be safely applied to mediastinal metastatic lymph nodes recurrence from esophageal carcinoma.

  3. CT evaluation of complications of cryoablation treatment in lung cancer

    International Nuclear Information System (INIS)

    Zhu Caiqiao; Chen Yao; Zhang Zhitian; Su Jinzhan; Huang Zhen; Bao Kaikai

    2011-01-01

    Objective: To assess the complications of percutaneous targeted Argon-Helium cryoablation treatment in patients with lung cancer on CT. Methods: Ten patients with unresectable lung cancer were treated by cryotherapy under CT guidance with Argon-Helium cryoablation system. Dynamic contrast-enhanced CT was performed to assess changes before and after treatment, complications and treatment response. Results: Ice ball coverage immediately after surgery was satisfactory in all patients. There were a few complications including worsening hoarseness (1), small pneumothorax (1), and small amount of bleeding at the site of probe puncture (1). Conclusion: Percutaneous targeted Argon-Helium cryoablation guided by CT is an effective treatment for lung cancer without severe complications. (authors)

  4. The percutaneous interventional therapy of lung abscess and pyothorax under the CT guidance

    International Nuclear Information System (INIS)

    Gao Xinghan; Zhu Zhenfang; Lv Fanzhen; Yan Dejun; Su Baomin

    2003-01-01

    Objective: To study the indication, the procedure, the necessity and feasibility of the percutaneous interventional therapy of lung abscess and pyothorax under the CT guidance. Methods: The group included 18 patients who received percutaneous interventional therapy of lung abscess and pyothorax. Results: 13 patients were cured by a single procedure, 3 patients received twice intervention. Triple therapies were done in 2 patients. 2 cases out of 18 were eventually diagnosed as peripheral lung cancer. The body temperature and the WBC count returned to normal range after the procedures. 16 patients completely recovered in 1-5 weeks after the therapies. Conclusion: The interventional therapy under CT guidance not only helps the diagnosis and differential diagnosis of chronic or acute lung abscess and pyothorax, but also shortens the course of treatment and avoids the open surgery. It is a safe, simple and convenient method

  5. An update on the drainage of pyogenic lung abscesses

    Directory of Open Access Journals (Sweden)

    Siraj O Wali

    2012-01-01

    Full Text Available Most lung abscesses (80-90% are now successfully treated with antibiotics; however, this conservative approach may occasionally fail. When medical treatment fails, pulmonary resection is usually advised. Alternatively, percutaneous transthoracic tube drainage or endoscopic drainage can be considered, though both remain controversial. In this communication, the medical literature focusing on percutaneous tube drainage efficacy, indications, techniques, complications, and mortality, as well as available data regarding endoscopic drainage are reviewed.

  6. Vertebral split fractures: Technical feasibility of percutaneous vertebroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Huwart, Laurent, E-mail: huwart.laurent@wanadoo.fr [Department of Radiology, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France); Foti, Pauline, E-mail: pfoti@hotmail.fr [Department of Biostatistics, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France); Andreani, Olivier, E-mail: andreani.olivier@gmail.com [Department of Radiology, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France); Hauger, Olivier, E-mail: olivier.hauger@chubordeaux.fr [Department of Radiology, Hôpital Pellegrin, Centre Hospitalo-Universitaire de Bordeaux, Bordeaux (France); Cervantes, Elodie, E-mail: elodie.cervantes@live.fr [Department of Radiology, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France); Brunner, Philippe, E-mail: pbrunner@chpg.mc [Department of Radiology, Hôpital Princesse Grasse de Monaco (Monaco); Boileau, Pascal, E-mail: boileau.p@chu-nice.fr [Department of Orthopedic Surgery, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France); Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr [Department of Radiology, Hôpital Archet 2, Centre Hospitalo-Universitaire de Nice, Nice (France)

    2014-01-15

    Objective: The treatment of vertebral split fractures remains controversial, consisting of either corset or internal fixation. The aim of this study was to evaluate the technical feasibility of CT- and fluoroscopy-guided percutaneous vertebroplasty in the treatment of vertebral split fractures. Materials and methods: Institutional review board approval and informed consent were obtained for this study. Sixty-two consecutive adult patients who had post-traumatic vertebral split fractures (A2 according to the AO classification) without neurological symptoms were prospectively treated by percutaneous vertebroplasty. All these procedures were performed by an interventional radiologist under computed tomography (CT) and fluoroscopy guidance by using only local anaesthesia. Postoperative outcome was assessed using the visual analogue scale (VAS) and Oswestry disability index (ODI) scores. Results: Vertebroplasty was performed on thoracic and lumbar vertebrae, creating a cement bridge between the displaced fragment and the rest of the vertebral body. Seven discal cement leakages (11%) were observed, without occurrence of adjacent vertebral compression fractures. The mean VAS measurements ± standard deviation (SD) significantly decreased from 7.9 ± 1.5 preoperatively to 3.3 ± 2.1 at 1 day, 2.2 ± 2.0 at 1 month, and 1.8 ± 1.4 at 6 months (P < 0.001). The mean ODI scores ± SD had also a significant improvement: 62.3 ± 17.2 preoperatively and 15.1 ± 6.0 at the 6-month follow-up (P < 0.001). Conclusion: This study suggests that type A2 vertebral fractures could be successfully treated by CT- and fluoroscopy-guided percutaneous vertebroplasty.

  7. Vertebral split fractures: Technical feasibility of percutaneous vertebroplasty

    International Nuclear Information System (INIS)

    Huwart, Laurent; Foti, Pauline; Andreani, Olivier; Hauger, Olivier; Cervantes, Elodie; Brunner, Philippe; Boileau, Pascal; Amoretti, Nicolas

    2014-01-01

    Objective: The treatment of vertebral split fractures remains controversial, consisting of either corset or internal fixation. The aim of this study was to evaluate the technical feasibility of CT- and fluoroscopy-guided percutaneous vertebroplasty in the treatment of vertebral split fractures. Materials and methods: Institutional review board approval and informed consent were obtained for this study. Sixty-two consecutive adult patients who had post-traumatic vertebral split fractures (A2 according to the AO classification) without neurological symptoms were prospectively treated by percutaneous vertebroplasty. All these procedures were performed by an interventional radiologist under computed tomography (CT) and fluoroscopy guidance by using only local anaesthesia. Postoperative outcome was assessed using the visual analogue scale (VAS) and Oswestry disability index (ODI) scores. Results: Vertebroplasty was performed on thoracic and lumbar vertebrae, creating a cement bridge between the displaced fragment and the rest of the vertebral body. Seven discal cement leakages (11%) were observed, without occurrence of adjacent vertebral compression fractures. The mean VAS measurements ± standard deviation (SD) significantly decreased from 7.9 ± 1.5 preoperatively to 3.3 ± 2.1 at 1 day, 2.2 ± 2.0 at 1 month, and 1.8 ± 1.4 at 6 months (P < 0.001). The mean ODI scores ± SD had also a significant improvement: 62.3 ± 17.2 preoperatively and 15.1 ± 6.0 at the 6-month follow-up (P < 0.001). Conclusion: This study suggests that type A2 vertebral fractures could be successfully treated by CT- and fluoroscopy-guided percutaneous vertebroplasty

  8. Usefulness of automated biopsy guns in image-guided biopsy

    International Nuclear Information System (INIS)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi

    1994-01-01

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis

  9. Usefulness of automated biopsy guns in image-guided biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Hyung; Rhee, Chang Soo; Lee, Sung Moon; Kim, Hong; Woo, Sung Ku; Suh, Soo Jhi [School of Medicine, Keimyung University, Daegu (Korea, Republic of)

    1994-12-15

    To evaluate the usefulness of automated biopsy guns in image-guided biopsy of lung, liver, pancreas and other organs. Using automated biopsy devices, 160 biopsies of variable anatomic sites were performed: Biopsies were performed under ultrasonographic(US) guidance in 95 and computed tomographic (CT) guidance in 65. We retrospectively analyzed histologic results and complications. Specimens were adequate for histopathologic diagnosis in 143 of the 160 patients(89.4%)-Diagnostic tissue was obtained in 130 (81.3%), suggestive tissue obtained in 13(8.1%), and non-diagnostic tissue was obtained in 14(8.7%). Inadequate tissue was obtained in only 3(1.9%). There was no statistically significant difference between US-guided and CT-guided percutaneous biopsy. There was no occurrence of significant complication. We have experienced mild complications in only 5 patients-2 hematuria and 2 hematochezia in transrectal prostatic biopsy, and 1 minimal pneumothorax in CT-guided percutaneous lung biopsy. All of them were resolved spontaneously. The image-guided biopsy using the automated biopsy gun was a simple, safe and accurate method of obtaining adequate specimen for the histopathologic diagnosis.

  10. Septic bursitis after ultrasound-guided percutaneous treatment of rotator cuff calcific tendinopathy.

    Science.gov (United States)

    Sconfienza, Luca Maria; Randelli, Filippo; Sdao, Silvana; Sardanelli, Francesco; Randelli, Pietro

    2014-08-01

    Calcific tendinopathy of the rotator cuff is a common condition. Ultrasound-guided percutaneous aspiration is one of several options to treat this condition. The main advantages of this procedure are short duration, good outcome, and low cost. Furthermore, only minor complications have been reported in the literature, namely, vagal reactions during the procedure and mild postprocedural pain. We report the first case of septic bursitis after ultrasound-guided percutaneous treatment of calcific tendinopathy. Although this is generally considered a very safe procedure, a risk of infection should be taken into account. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  12. Biopsy system for CT-guided biopsies

    International Nuclear Information System (INIS)

    Onik, G.; Cosman, E.; Wells, T.; Goldberg, H.I.; Moss, A.; Costello, P.; Kane, R.

    1987-01-01

    CT stereotaxic brain biopsies have made brain biopsies safe and minimally invasive. CT-guided biopsies of the body, however, have traditionally used a hand-guidance method. CT biopsy guidance systems for the body have recently become available that have similar capabilities as those of brain biopsy systems. To compare the clinical utility of stereotaxically guided biopsies with hand-guided biopsies, the authors prospectively compared 40 biopsies performed with each method. In the stereotaxic method, a localizor grid was placed on the patient to define a reference point, and a frame was used to guide the needle along the intended path. Computer software programs calculated complex paths from one scan plane to another. Although the results disclosed no significant differences in lesion size or path length between the two groups, the stereotaxically guided biopsies required 75% fewer needle manipulations to hit the intended target. Consequently, the stereotaxically guided biopsies required 40% less time and 80% fewer localization scans to find the biopsy needle than did the hand-guided biopsies

  13. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    International Nuclear Information System (INIS)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja; Im, Hyoung June

    2010-01-01

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  14. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and Nuclear Medicine; Hartwig, T.; Disch, A.C. [Charite University Medicine Berlin (Germany). Center for Musculoskeletal Surgery

    2014-06-15

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  15. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    International Nuclear Information System (INIS)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F.; Bretschneider, T.; Hartwig, T.; Disch, A.C.

    2014-01-01

    Purpose: To evaluate and compare the costs of MRI-guided and CT-guided cervical nerve root infiltration for the minimally invasive treatment of radicular neck pain. Materials and Methods: Between September 2009 and April 2012, 22 patients (9 men, 13 women; mean age: 48.2 years) underwent MRI-guided (1.0 Tesla, Panorama HFO, Philips) single-site periradicular cervical nerve root infiltration with 40 mg triamcinolone acetonide. A further 64 patients (34 men, 30 women; mean age: 50.3 years) were treated under CT fluoroscopic guidance (Somatom Definition 64, Siemens). The mean overall costs were calculated as the sum of the prorated costs of equipment use (purchase, depreciation, maintenance, and energy costs), personnel costs and expenditure for disposables that were identified for MRI- and CT-guided procedures. Additionally, the cost of ultrasound guidance was calculated. Results: The mean intervention time was 24.9 min. (range: 12-36 min.) for MRI-guided infiltration and 19.7 min. (range: 5-54 min.) for CT-guided infiltration. The average total costs per patient were EUR 240 for MRI-guided interventions and EUR 124 for CT-guided interventions. These were (MRI/CT guidance) EUR 150/60 for equipment use, EUR 46/40 for personnel, and EUR 44/25 for disposables. The mean overall cost of ultrasound guidance was EUR 76. Conclusion: Cervical nerve root infiltration using MRI guidance is still about twice as expensive as infiltration using CT guidance. However, since it does not involve radiation exposure for patients and personnel, MRI-guided nerve root infiltration may become a promising alternative to the CT-guided procedure, especially since a further price decrease is expected for MRI devices and MR-compatible disposables. In contrast, ultrasound remains the less expensive method for nerve root infiltration guidance. (orig.)

  16. MRI-Guided Percutaneous Biopsy of Mediastinal Masses Using a Large Bore Magnet: Technical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, J., E-mail: juliengarnon@gmail.com [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Ramamurthy, N., E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Caudrelier J, J., E-mail: caudjean@yahoo.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France); Erceg, G., E-mail: erceggorislav@yahoo.com; Breton, E., E-mail: ebreton@unistra.fr [ICube, University of Strasbourg, CNRS (France); Tsoumakidou, G., E-mail: gtsoumakidou@yahoo.com; Rao, P., E-mail: pramodrao@me.com; Gangi, A., E-mail: gangi@unistra.fr [Nouvel Hôpital Civil, Department of Interventional Radiology (France)

    2016-05-15

    ObjectiveTo evaluate the diagnostic accuracy and safety of magnetic resonance imaging (MRI)-guided percutaneous biopsy of mediastinal masses performed using a wide-bore high-field scanner.Materials and MethodsThis is a retrospective study of 16 consecutive patients (8 male, 8 female; mean age 74 years) who underwent MRI-guided core needle biopsy of a mediastinal mass between February 2010 and January 2014. Size and location of lesion, approach taken, time for needle placement, overall duration of procedure, and post-procedural complications were evaluated. Technical success rates and correlation with surgical pathology (where available) were assessed.ResultsTarget lesions were located in the anterior (n = 13), middle (n = 2), and posterior mediastinum (n = 1), respectively. Mean size was 7.2 cm (range 3.6–11 cm). Average time for needle placement was 9.4 min (range 3–18 min); average duration of entire procedure was 42 min (range 27–62 min). 2–5 core samples were obtained from each lesion (mean 2.6). Technical success rate was 100 %, with specimens successfully obtained in all 16 patients. There were no immediate complications. Histopathology revealed malignancy in 12 cases (4 of which were surgically confirmed), benign lesions in 3 cases (1 of which was false negative following surgical resection), and one inconclusive specimen (treated as inaccurate since repeat CT-guided biopsy demonstrated thymic hyperplasia). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in our study were 92.3, 100, 100, 66.7, and 87.5 %, respectively.ConclusionMRI-guided mediastinal biopsy is a safe procedure with high diagnostic accuracy, which may offer a non-ionizing alternative to CT guidance.

  17. Ultrasound-Guided Drainage of Supralevator Hematoma in a Hemodynamically Stable Patient.

    Science.gov (United States)

    Mukhopadhyay, Debjani; Jennings, Paul E; Banerjee, Mamta; Gada, Ruta

    2015-12-01

    Paravaginal hematomas can be life-threatening. In patients with intact vaginal walls and perineum, they may pose a diagnostic and therapeutic challenge. Supralevator hematomas are much less common than infralevator hematomas. We present a case of puerperal hemorrhagic shock after a normal vaginal delivery in a low-risk parous woman resulting from an occult supralevator hematoma. Because the woman was hemodynamically unstable initially, she underwent a vaginal surgical drainage. A week later, the supravaginal hematoma reformed. At this time the patient was hemodynamically stable, and ultrasound-guided drainage was performed, which resulted in complete resolution of the hematoma within 10 days. In a clinically stable puerperal patient, ultrasound-guided drainage of a supralevator hematoma resulted in rapid and complete resolution of symptoms.

  18. [A clinical observation of percutaneous balloon dilation and maintenance percutaneous transhepatic cholangial catheter drainage for treatment of 21 patients with benign biliary strictures and difficult endoscopy].

    Science.gov (United States)

    Pan, Jie; Shi, Hai-feng; Li, Xiao-guang; Zhang, Xiao-bo; Liu, Wei; Jin, Zheng-yu; Hong, Tao; Yang, Ai-ming; Yang, Ning

    2012-06-01

    To investigate the value of percutaneous balloon dilation and percutaneous transhepatic cholangial drainage (PTCD) catheter maintenance in the treatment of benign biliary strictures. The clinical data of 21 patients with benign biliary strictures at Peking Union Medical College Hospital from June 2005 to June 2011 were retrospectively studied, in which 12 patients in severe stricture (stenosis > 70%) were treated with percutaneous balloon dilation and PTCD catheter placed across the stricture, while another 9 patients in median stricture (stenosis stenosis was seen in 2 patients. A severe complication with biliary artery branch rupture and massive hemobilia was seen in 1 patient during balloon dilation. Of the 9 patients only treated with 1 - 12 months (median: 6 months) of PTCD catheter placement, 7 patients had the catheter successfully removed. In the follow-up of 5 - 18 months (median: 8 months), patency of bile duct was preserved in 5 of 7 patients, and recurrent stenosis was seen in 2 patients. No severe complication occurred. When endoscopy therapy is failed or the patient can't undergo endoscopy therapy, the percutaneous balloon dilation and PTCD catheter maintenance method is an effective alternative therapeutic approach in the treatment of benign biliary strictures. The moderate benign biliary stricture may be effectively treated only by the PTCD catheter maintenance method.

  19. Point-of-Care Ultrasound-Guided Percutaneous Cannulation of Extracorporeal Membrane Oxygenation: Make it Simple.

    Science.gov (United States)

    Ahn, Hong Joon; Lee, Jun Wan; Joo, Ki Hyuk; You, Yeon Ho; Ryu, Seung; Lee, Jin Woong; Kim, Seung Whan

    2017-12-30

    Cannulation of the great vessels is required for extracorporeal membrane oxygenation (ECMO). Currently, there is no guideline for optimal imaging modalities during percutaneous cannulation of ECMO. The purpose of this study was to describe percutaneous cannulation guided by point-of-care ultrasound (POCUS) for ECMO and compare it with fluoroscopy and landmark guidance. Three groups (POCUS-, fluoroscopy-, and landmark-guided) of percutaneous cannulation for ECMO were analyzed retrospectively in a tertiary academic hospital. In the POCUS-guided group, visual confirmation of guidewire and cannula by ultrasound in both the access and return cannula were essential for successful cannulation. Fluoroscopy- and landmark-guided groups were cannulated with the conventional technique. A total of 128 patients were treated by ECMO during the study period, of which 94 (73.4%) cases were venoarterial ECMO. This included 56 cases of extracorporeal cardiopulmonary resuscitation. Also, there were 30 (23.4%) cases of venovenous ECMO and 4 (3.1%) cases of venoarteriovenous ECMO. A total of 71 (55.5%) patients were cannulated under POCUS guidance, and 43 (33.6%) patients were cannulated under fluoroscopy guidance and 14 (10.9%) patients were cannulated by landmark guidance. No surgical cut downs were required. Misplacement of cannula occurred in 3 (2.3%) cases. All three occurred in the landmark-guided group. POCUS-guided cannulation is comparable to fluoroscopy-guided cannulation in terms of avoiding cannula misplacement. In our experience, POCUS-guided cannulation is a useful strategy over fluoroscopy- and landmark-guided cannulation during peripheral ECMO. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Radiologic drainage of infected and noninfected thoracic fluid collections

    International Nuclear Information System (INIS)

    Van Sonnenberg, E.; Casola, G.; Stavas, J.; Neff, C.C.; Varney, R.A.; Wittich, G.R.; Dillard, J.; Christensen, R.A.; Friedman, P.J.

    1987-01-01

    Radiologically guided drainage of 100 thoracic fluid collections is described in this paper. Collections that underwent drainage include empyemas, lung abscesses, bronchopleural fistulas (BPFs), mediastinal abscesses, paracardial collections, bronchogenic cysts, sequestrations, lymphoceles, lymphangiomas, malignant effusions, and necrotic tumors. Catheters were placed for sclerotherapy in nine patients. Guidance modalities (in descending order of frequency) were CT, US, fluoroscopy, and MR. Inadequate thoracostomy tube drainage occurred in a third of the patients prior to radiologic drainage. Drainages were effective in 85% of cases, sparing surgery or another thoracostomy tube. Complications occurred in 7% of patients, most being minor and none requiring operation. Criteria for drainage of lung abscess and BPF will be emphasized, as will techniques and methods of follow-up

  1. Realtime ultrasound guided percutaneous tracheostomy in emergency setting: the glass ceiling has been broken.

    Science.gov (United States)

    Ravi, Parli Raghavan; Vijai, M N; Shouche, Sachin

    2017-01-01

    In recent years ultrasound guided percutaneous tracheostomy (USPCT) has become a routine practice in critical care units. Its safety and superiority over conventional percutaneous tracheostomy and bronchoscopic guided PCT is proven to be non-inferior in elective cases. However its role in emergency percutaneous tracheostomy has never been studied, since percutaneous tracheostomy itself remains an enigma in accessing emergency airway. There is no report of use of ultrasound guided percutaneous tracheostomy in emergency setting so far in the literature. We report our early experience with USPCT in emergency setting. Sixteen adult patients who required access to an emergency surgical airway after failure to accomplish emergency oro-tracheal intubation were the study population. Their airway was accessed by USPCT. Recorded data included clinical and demographic data including time taken to perform the procedure and complications. Short term and long term follow ups for a period of 2 years were done for the survivors. Twelve male and four female patients underwent the procedure and the average time of the procedure was 3.6 min with no failures nor conversions to surgical tracheostomy and no complications. The average oxygen saturation was 86% and average Glasgow coma scale was 8.4. This time period included the oxygen insufflation time. 10 patients were decannulated while six patients died due to the pathology of the disease itself. There were no complications in either short term or long term follow up. USPCT has a definitive role in emergency both in trauma and non-trauma setting. It is safe, feasible and faster in experienced hands. Use of USPCT in emergency setting has further narrowed the list of contraindications of percutaneous tracheostomy.

  2. Percutaneous sclerotherapy of the internal spermatic vein for varicocele through an open ended guide wire

    Energy Technology Data Exchange (ETDEWEB)

    Wilms, G.; Oyen, R.; Casselman, J.; Baert, A.L.

    1987-08-01

    Percutaneous sclerotherapy of the internal spermatic vein through an open ended guide wire was performed in 50 patients with left sided variocele. The procedure was successful in 47 patients, without major complications. Percutaneous sclerotherapy through an open ended guide wire offers the advantage of very distal and superselective catheterization with complete embolization of the internal spermatic vein, its side branches and parallel collateral channels. Further follow-up hopefully will confirm the reduction of recurrence rate in our patients.

  3. Preoperative percutaneous transhepatic internal drainage in obstructive jaundice: a randomized, controlled trial examining renal function.

    Science.gov (United States)

    Smith, R C; Pooley, M; George, C R; Faithful, G R

    1985-06-01

    Thirty patients with obstructive jaundice with plasma bilirubin values greater than 200 mumol/L were randomized at the time of percutaneous transhepatic Cholangiography to undergo immediate or delayed surgery. The patients who had preoperative percutaneous transhepatic biliary drainage (PTBD) for 13.8 +/- 5.8 days had fewer surgical complications than did patients who underwent immediate surgery (p less than 0.02), although when the complications of PTBD were included this advantage was diminished. Immediate surgery caused greater deterioration of renal function as measured by plasma urea, plasma B 2-microglobulin, phosphate clearance, uric acid clearance, and maximal concentrating ability than occurred after PTBD or delayed surgery. The improvement in phosphate clearance that followed PTBD was sustained through delayed surgical treatment, indicating better tubular function in these patients. This article supports the concept that preoperative PTBD will reduce surgical morbidity and will result in less renal impairment than will immediate surgery. However, the morbidity rates of the PTBD procedure will preclude its wide use.

  4. Computed tomography-guided percutaneous ozone injection of the Gasserian ganglion for the treatment of trigeminal neuralgia

    Directory of Open Access Journals (Sweden)

    An JX

    2018-01-01

    Full Text Available Jian-Xiong An,1,2 Hui Liu,1 Ruo-Wen Chen,1,2 Yong Wang,1 Wen-Xing Zhao,1 Derek Eastwood,3 John P Williams4 1Department of Anesthesiology, Pain Medicine & Critical Care Medicine, Aviation General Hospital of China Medical University & Beijing Institute of Translational Medicine, Chinese Academy of Sciences, 2Department of Anesthesiology, Weifang Medical University, Beijing, People’s Republic of China; 3Department of Pain Services, Wirral University Teaching Hospital, Wirral, Merseyside, UK; 4Department of Anesthesiology, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA Objective: The aim of this study was to evaluate the therapeutic effect of computed tomography (CT-guided percutaneous ozone injection for refractory trigeminal neuralgia. Design: A retrospective evaluation was performed in the study. Setting: The study was conducted at a university hospital pain center. Patients and methods: A total of 29 patients with a clinical diagnosis of refractory trigeminal neuralgia were enrolled. All patients were treated with a percutaneous ozone injection and one patient was excluded. There were 21 patients with classical trigeminal neuralgia (group A and seven patients with painful trigeminal neuropathy caused by post-herpetic neuralgia (group B. The percutaneous injection was an oxygen–ozone mixture at an ozone concentration of 30 mg/­mL into the Gasserian ganglion performed under CT guidance. The number of ­procedures performed varied from one to as many as 16. Outcomes were evaluated using visual analog scale (VAS pain scores. Results: The combined VAS scores were 7.11 ± 1.23 pretreatment, 2.86 ± 1.69 posttreatment (P < 0.05 and 3.25 ± 2.01 after 6-month follow-up (P < 0.05. In group A, the VAS scores were 7.10 ± 1.04 pretreatment and 2.90 ± 1.84 posttreatment (P < 0.05. In group B, the VAS scores were 7.14 ± 1.77 pretreatment and 2.71 ± 1.25 posttreatment (P < 0.05. After 6-months follow-up, the VAS score was 3.38

  5. Percutaneous image-guided needle biopsy in children - summary of our experience with 57 children

    International Nuclear Information System (INIS)

    Sklair-Levy, M.; Lebensart, P.D.; Applbaum, Y.H.; Bar-Ziv, J.; Libson, E.; Ramu, N.; Freeman, A.; Gozal, D.; Gross, E.; Sherman, Y.

    2001-01-01

    Background: Percutaneous image-guided needle biopsy in children has been slower to gain acceptance than in adults where it is regarded as the standard clinical practice in screening suspicious masses. Objectives: To report our experience with percutaneous image-guided needle biopsy in the pediatric population and assess its clinical use, efficacy and limitations. Material and methods: Sixty-nine percutaneous image-guided needle biopsies were performed in 57 children. The age of the children ranged from 4 days to 14 years (mean 5.6 years). We used 16- to-20-gauge cutting-edge needles. Sixty-two biopsies were core-needle biopsies and 7 fine-needle aspiration biopsies. Results: There were 50 malignant lesions, 10 benign lesions and 2 infectious lesions. In 55 (88.7 %) lesions the needle biopsy was diagnostic. In 7 (11.3 %) the biopsy was non-diagnostic and the diagnosis was made by surgery. Core-needle biopsy was diagnostic in 47 of 50 (94 %) of the malignant solid tumors. In 3 out of 5 children with lymphoma, an accurate diagnosis was obtained with needle aspiration. Seven children underwent a repeated core-needle biopsy, (5 for Wilms' tumor and 2 for neuroblastoma) that was diagnostic in all cases. All the biopsies were performed without complications. Conclusion: Percutaneous image-guided needle biopsy is a simple, minimally invasive, safe and accurate method for the evaluation of children with suspicious masses. These data suggest that image-guided needle biopsy is an excellent tool for diagnosing solid tumors in the pediatric population. Negative studies should be considered nondiagnostic and followed by excisional surgical biopsies when clinical suspicion of malignancy is high. (orig.)

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... to: guide biopsies and other procedures such as abscess drainages and minimally invasive tumor treatments. plan for ... many types of tissue as well as the lungs, bones, and blood vessels. CT examinations are fast ...

  7. The use of computerised tomography guided percutaneous fine needle aspiration in the evaluation of solitary pulmonary nodules.

    LENUS (Irish Health Repository)

    Khan, K A

    2012-02-01

    The evaluation of a solitary pulmonary nodule (SPN) has changed over the years with increased access to percutaneous computerised tomography (CT) guided fine needle aspiration (FNA), where bronchoscopy is unhelpful. The aim of our study was to evaluate the sample adequacy, diagnostic and complication rate of CT-FNA of a SPN at our academic teaching hospital over an 18 month period. CT-FNA was performed by a radiologist, with a cytopathologist in attendance to confirm the adequacy of the sample obtained. The size of the nodule, sample material and adequacy, diagnosis and complications were recorded. A total of 101 patients were included, 54 male and the mean age was 68 +\\/- 11 years. The mean size of the SPN was 2.3 cm (range 1-11 cm). 56 (56%) patients had a right SPN, 45 (45%) had a left SPN. CT-FNA was diagnostic in 80 (80%) patients and non-diagnostic in 21 (20%) patients. The sample was insufficient for immunocytochemistry, although the morphological appearance was diagnostic in 20 (25%) of the 80 patients. Pneumothorax occurred in 26\\/101 (26%) patients post CT-FNA, of these 7 (27%) required chest drain insertion, while 19 (73%) were managed conservatively. CT FNA is a useful tool for the diagnosis of a SPN, with our diagnostic accuracy comparable to that reported in the literature. However, CT-FNA may not provide adequate sample volume to perform ancillary testing and has a moderate complication rate.

  8. Percutaneous discectomy on lumbar radiculopathy related to disk herniation: Why under CT guidance? An open study of 100 consecutive patients

    International Nuclear Information System (INIS)

    Amoretti, Nicolas; Hauger, Olivier; Marcy, Pierre-Yves; Amoretti, Marie-eve; Lesbats, Virginie; Yvonne, Maratos; Ianessi, Antoine; Boileau, Pascal

    2012-01-01

    The primary objective of this study conducted on 100 patients is to demonstrate that performing CT-guided percutaneous discectomy for herniated disks results in a significant improvement in pain symptoms at several times (D1, D2, D7, 1 month, 3 months, 6 months). This objective assesses the effectiveness and feasibility of this technique under CT guidance in patients presenting documented lower back pain related to disk herniation that has not improved with appropriate medical treatment. The impact of various factors on the effectiveness of discectomy will also be evaluated. At 1 week, we notes a decrease in average VAS respectively of 71% and 67% in patients treated for posterolateral and foraminal herniated disks; the result for posteromedian herniated disks is only 45% in average decrease. At 6 months post op, 79% of lateralized herniated disks have a satisfactory result (≥70% decrease in pain as compared to initial pain), whereas post median herniated disks had a satisfactory result in only 50% of cases. Percutaneous fine needle discectomy probe under combined CT and fluoroscopic guidance is a minimally invasive spine surgery which should be considered as an alternative to surgery. This technique presents several advantages: the small diameter of the probe used (maximum 16G or 1.5 mm) allows a cutaneous incision of only a few millimeters, and a trans-canal approach can be possible; it also decreases the risk of ligamentary lesion and does not cause an osseous lesion of the posterior arc or of the adjacent muscular structures.

  9. Time-dependent analysis of incidence, risk factors and clinical significance of pneumothorax after percutaneous lung biopsy.

    Science.gov (United States)

    Lim, Woo Hyeon; Park, Chang Min; Yoon, Soon Ho; Lim, Hyun-Ju; Hwang, Eui Jin; Lee, Jong Hyuk; Goo, Jin Mo

    2018-03-01

    To evaluate the time-dependent incidence, risk factors and clinical significance of percutaneous lung biopsy (PLB)-related pneumothorax. From January 2012-November 2015, 3,251 patients underwent 3,354 cone-beam CT-guided PLBs for lung lesions. Cox, logistic and linear regression analyses were performed to identify time-dependent risk factors of PLB-related pneumothorax, risk factors of drainage catheter insertion and those of prolonged catheter placement, respectively. Pneumothorax occurred in 915/3,354 PLBs (27.3 %), with 230/915 (25.1 %) occurring during follow-ups. Risk factors for earlier occurrence of PLB-related pneumothorax include emphysema (HR=1.624), smaller target (HR=0.922), deeper location (HR=1.175) and longer puncture time (HR=1.036), while haemoptysis (HR=0.503) showed a protective effect against earlier development of pneumothorax. Seventy-five cases (8.2 %) underwent chest catheter placement. Mean duration of catheter placement was 3.2±2.0 days. Emphysema (odds ratio [OR]=2.400) and longer puncture time (OR=1.053) were assessed as significant risk factors for catheter insertion, and older age (parameter estimate=1.014) was a predictive factor for prolonged catheter placement. PLB-related pneumothorax occurred in 27.3 %, of which 25.1 % developed during follow-ups. Smaller target size, emphysema, deeply-located lesions were significant risk factors of PLB-related pneumothorax. Emphysema and older age were related to drainage catheter insertion and prolonged catheter placement, respectively. • One-fourth of percutaneous lung biopsy (PLB)-related pneumothorax occurs during follow-up. • Smaller, deeply-located target and emphysema lead to early occurrence of pneumothorax. • Emphysema is related to drainage catheter insertion for PLB-related pneumothorax. • Older age may lead to prolonged catheter placement for PLB-related pneumothorax. • Tailored management can be possible with time-dependent information of PLB-related pneumothorax.

  10. US-guided percutaneous ethanol injection in Plummer's adenoma

    International Nuclear Information System (INIS)

    Lagalla, R.; Iovane, A.; Caruso, G.; Midiri, N.; Oliveri, D.; Brancato, G.; Cardinale, A.

    1991-01-01

    The authors report their experience in the study of 8 patients showing sympoms of thyroid hyperfunction (Plummer's adenoma) and treated with US-guided percutaneous ethanol injection. The treatment consisted in injecting sterile ethanol in varying amounts (2 to 5 ml) according to nodule size, using a fine needle under US guidance. The patients underwent 3 to 6 injections, according to biochemical (T3-T4-TSH) and scintigraphic findings. Follow-up ay 12 months showed regression of clinical symptoms, a trend of hormone levels toward normalization and recovery of previously suppressed parenchymal function. No significant complications were observed, except for a transient thyrotoxic crisis in the patient bearing the largest nodule. The treatment of Plummer's adenoma by means of percutaneous ethanol injection under us guidance appears to provide specific clinical and technical advantages over other conventional treatments

  11. CT diagnosis of subphrenic abscess after splenectomy for trauma; Ruolo della tomografia computerizzata nella valutazione degli ascessi subfrenici dopo splenectomia post-traumatica

    Energy Technology Data Exchange (ETDEWEB)

    Salzano, A. [Ospedale Loreto-Mare, Neaples (IT). Serv. di Radiologia] [and others

    1999-09-01

    The paper studies subphrenic inflammatory abscesses and splenic fluid collections after splenectomy for trauma. These complications may appear early or late postoperatively; they are easily demonstrated with computerized tomography, which permits accurate spatial assessment of the lesions and appropriate treatment with percutaneous drainage. It has been also investigates the diagnostic accuracy of the CT in subphrenic inflammatory conditions after emergency splenectomy for traumatic spleen rupture and found that CT is a precious tool for rapid and easy diagnosis and follow-up of subphrenic abscesses treated with percutaneous drainage. [Italian] Scopo del lavoro e' di valutare il ruolo della tomografia computerizzata nelle flogrosi subfreniche secondarie a splenectomia d'urgenza per rottura traumatica della milza, documentando come tale metodica risulti accurata nel diagnosticare e monitorare in modo semplice e rapido l'evoluzione e il controllo degli ascessi subfrenici trattati con drenaggio percutaneo.

  12. CT-guided percutaneous core needle biopsy in deep seated musculoskeletal lesions: a prospective study of 128 cases

    International Nuclear Information System (INIS)

    Puri, A.; Shingade, V.U.; Agarwal, M.G.; Anchan, C.; Juvekar, S.; Desai, S.; Jambhekar, N.A.

    2006-01-01

    Although large lesions of the limbs can easily be biopsied without image guidance, lesions in the spine, paraspinal area and pelvis are difficult to target, and benefit from CT guidance to improve the accuracy of targeting the lesion for biopsy purposes. A prospective study of CT-guided core needle biopsies for deep-seated musculoskeletal lesions was conducted at a referral cancer institute over a 4-year period with the aim of assessing the safety and efficacy of the procedure. From January 2000 to December 2003, 136 consecutive CT-guided biopsy sessions were undertaken for musculoskeletal lesions in 128 patients comprising 73 males and 55 females. The following data was recorded in all patients: demographic data, suspected clinicoradiological diagnosis, data related to core biopsy session (date, site, approach, total time required in minutes, number of cores, surgeon satisfaction with adequacy of cores), patient discomfort, complications, histopathology report and number of further sessions if material obtained during the first biopsy session was not confirmatory. The sample obtained during the biopsy session was considered inconclusive if, in the opinion of the pathologist, inadequate or non-representative tissue had been obtained. The diagnosis was considered inaccurate if the final histopathological diagnosis did not match with the biopsy diagnosis, or if subsequent clinicoradiological evaluation at follow up did not correlate with the biopsy diagnosis in those patients who were treated with modalities other than surgery. In 121 patients, a single session was sufficient to obtain representative material, whilst for six patients two sessions, and for one patient three sessions were necessary. The time taken for biopsy, including the pre-biopsy CT examination time, varied from 15 min to 60 min (median 30 min). For 110 bony lesions 116 sessions were required, and for 18 soft-tissue lesions 20 sessions were required. 108 biopsy sessions yielded a diagnosis, whilst

  13. Percutaneous Management of Accidentally Retained Foreign Bodies During Image-Guided Non-vascular Procedures: Novel Technique Using a Large-Bore Biopsy System

    Energy Technology Data Exchange (ETDEWEB)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France); Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Tsoumakidou, Georgia, E-mail: georgia.tsoumakidou@chru-strasbourg.fr; Caudrelier, Jean, E-mail: jean.caudrelier@chru-strasbourg.fr; Thénint, Marie-Aude, E-mail: marie-aude.thenint@chru-strasbourg.fr; Rao, Pramod, E-mail: pramodrao@me.com; Koch, Guillaume, E-mail: guillaume.koch@chru-strasbourg.fr; Gangi, Afshin, E-mail: gangi@unistra.fr [Hôpitaux Universitaires de Strasbourg, HUS, Department of Interventional Radiology, Nouvel Hôpital Civil (France)

    2016-07-15

    ObjectiveTo describe a novel percutaneous image-guided technique using a large-bore biopsy system to retrieve foreign bodies (FBs) accidentally retained during non-vascular interventional procedures.Materials and MethodsBetween May 2013 and October 2015, five patients underwent percutaneous retrieval of five iatrogenic FBs, including a biopsy needle tip in the femoral head following osteoblastoma biopsy and radiofrequency ablation (RFA); a co-axial needle shaft within a giant desmoid tumour following cryoablation; and three post-vertebroplasty cement tails within paraspinal muscles. All FBs were retrieved immediately following original procedures under local or general anaesthesia, using combined computed tomography (CT) and fluoroscopic guidance. The basic technique involved positioning a 6G trocar sleeve around the FB long axis and co-axially advancing an 8G biopsy needle to retrieve the FB within the biopsy core. Retrospective chart review facilitated analysis of procedures, FBs, technical success, and complications.ResultsMean FB size was 23 mm (range 8–74 mm). Four FBs were located within 10 mm of non-vascular significant anatomic structures. The basic technique was successful in 3 cases; 2 cases required technical modifications including using a stiff guide-wire to facilitate retrieval in the case of the post-cryoablation FB; and using the central mandrin of the 6G trocar to push a cement tract back into an augmented vertebra when initial retrieval failed. Overall technical success (FB retrieval or removal to non-hazardous location) was 100 %, with no complications.ConclusionPercutaneous image-guided retrieval of iatrogenic FBs using a large-bore biopsy system is a feasible, safe, effective, and versatile technique, with potential advantages over existing methods.

  14. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    International Nuclear Information System (INIS)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens; Universidade Federal do Espirito Santo

    2017-01-01

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  15. Computed tomography-guided percutaneous gastrostomy: initial experience at a cancer center

    Energy Technology Data Exchange (ETDEWEB)

    Tyng, Chiang Jeng; Santos, Erich Frank Vater; Guerra, Luiz Felipe Alves; Bitencourt, Almir Galvao Vieira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Universidade Federal do Espirito Santo (HUCAM/UFES), Vitoria, ES (Brazil). Hospital Universitario Cassiano Antonio de Morais. Radiologia e Diagnostico por Imagem

    2017-03-15

    Gastrostomy is indicated for patients with conditions that do not allow adequate oral nutrition. To reduce the morbidity and costs associated with the procedure, there is a trend toward the use of percutaneous gastrostomy, guided by endoscopy, fluoroscopy, or, most recently, computed tomography. The purpose of this paper was to review the computed tomography-guided gastrostomy procedure, as well as the indications for its use and the potential complications. (author)

  16. CT scan-guided percutaneous osteosynthesis of a complex, multifocal fracture of the pelvic girdle in a 14-year-old adolescent

    International Nuclear Information System (INIS)

    Gagne, Pierre-Thomas; Bertrand, Anne-Sophie; Caudal, Amandine; El Hayek, Tony; Amoretti, Nicolas

    2014-01-01

    We report on a 14-year-old girl with minimally displaced pelvic girdle and acetabular roof fracture following motor vehicle trauma, treated percutaneously under CT and C-arm fluoroscopic guidance by an interventional radiologist. After informed consent from the patient's parents, under surgical aseptic conditions and under general anesthesia, three screws were positioned adequately under dual guidance by a radiologist and without immediate or long-term complication. The patient was mobilized 48 h after the procedure and resumed normal activities after 1 month. Even though the technique has been described before on adults, to our knowledge this is the first time it has been described on a pediatric patient. (orig.)

  17. MR guided percutaneous laser lumbar disk hernia ablation

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko [Jikei Univ., Chiba (Japan). Kashiwa Hospital; Abe, Toshiaki

    1998-03-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  18. MR guided percutaneous laser lumbar disk hernia ablation

    International Nuclear Information System (INIS)

    Hashimoto, Takuo; Terao, Tohru; Ishibashi, Toshihiro; Yuhki, Ichiro; Harada, Junta; Tashima, Michiko; Abe, Toshiaki.

    1998-01-01

    An MRI unit for interventional procedure is very useful for minimally invasive surgery of the brain and spine. Percutaneous laser disc decompression (PLDD) utilizing X-ray fluoroscopy is a relatively new less invasive procedure for treatment of lumbar disc herniation. MR guided laser surgery is applied to patients with disc herniation at our department. Approaching the target of the disc protrusion was easily conducted and vaporizing the disc hernia directly using a laser was possible under MR fluoroscopy. The purpose of the present study is to evaluate the usefulness of MR guided percutaneous laser disc hernia ablation (MR-guided PLDHA). As subjects, 36 patients with lumbar disc herniation, including 23 cases with L4/5 involvement and 13 cases with L5/S1 involvement were studied. Among these, 26 were males and 10 were females, age ranging from 24 to 62. We used an open type MR system (Hitachi, Airis 0.3T), a permanent, open configuration MR system. A YAG laser (LaserScope, USA) was used for PLDHA. An MR compatible 18G titanium needle 15 cm in length was used to puncture the herniated discs. The MR compatible needle was clearly visualized, and used to safely and accurately puncture the target herniated disc in each case with multidimensional guidance. Application of the laser was performed with MR guidance. The energy dose from the laser ranged from 800 to 2100 joules. In most cases, signs and symptoms improved in the patients immediately after disc vaporization. The overall success rate was 88.9%. The complication rate was 2.8%, including one case of discitis after PLDHA. MR fluoroscopy sequence permits near real time imaging and provides an easy approach to the therapeutic target of disc herniation. MR guided PLDHA is a minimally invasive procedure and is very useful for the treatment of lumbar disc protrusion. (author)

  19. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong [Huazhong University of Science and Technology, Cancer Center, Union Hospital, Tongji Medical College, Wuhan (China)

    2017-08-15

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. (orig.)

  20. A first-in-man study of 68Ga-nanocolloid PET-CT sentinel lymph node imaging in prostate cancer demonstrates aberrant lymphatic drainage pathways.

    Science.gov (United States)

    Doughton, Jacki A; Hofman, Michael S; Eu, Peter; Hicks, Rodney J; Williams, Scott G

    2018-05-04

    Purpose: To assess feasibility, safety and utility of a novel 68 Ga-nanocolloid radio-tracer with PET-CT lymphoscintigraphy for identification of sentinel lymph nodes (SLN). Methods: Pilot study of patients from a tertiary cancer hospital who required insertion of gold fiducials for prostate cancer radiation therapy. Participation did not affect cancer management. Ultrasound-guided transperineal intra-prostatic injection of PET tracer (iron oxide nanocolloid labelled with gallium-68) after placement of fiducials. PET-CT lymphoscintigraphy imaging at approximately 45 and 100 minutes after in-jection of tracer. The study was monitored using Bayesian trial design with the as-sumption that at least one sentinel lymph node (SLN) could be identified in at least two-thirds of cases with >80% confidence. Results: SLN identification was successful in all 5 participants, allowing completion of the pilot study as per protocol. No adverse effects were observed. Unexpected po-tential pathways for transit of malignant cells as well as expected regional drainage pathways were discovered. Rapid tracer drainage to pelvic bone, perivesical, mesorec-tal, inguinal and Virchow's nodes was identified. Conclusion: SLN identification using 68 Ga-nanocolloid PET-CT can be successfully performed. Non-traditional pathways of disease spread were identified including drainage to pelvic bone as well as perivesical, mesorectal, inguinal and Virchow's nodes. Prevalence of both aberrant and non-lymphatic pathways of spread should be further investigated with this technique. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  1. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  2. Performance of intra-procedural 18-fluorodeoxyglucose PET/CT-guided biopsies for lesions suspected of malignancy but poorly visualized with other modalities

    International Nuclear Information System (INIS)

    Cornelis, F.; Silk, M.; Takaki, H.; Durack, J.C.; Erinjeri, J.P.; Sofocleous, C.T.; Siegelbaum, R.H.; Maybody, M.; Solomon, S.B.; Schoder, H.

    2014-01-01

    We sought to evaluate the safety and the diagnostic success rate of percutaneous biopsies performed under intra-procedural 18 F-deoxyglucose (FDG) positron-emission tomography/computed tomography (PET/CT) guidance for lesions difficult to see with conventional cross-sectional imaging. From 2011 to 2013, consecutive clinically indicated percutaneous PET/CT-guided biopsies of 106 masses (mean size, 3.3 cm; range, 0.7-15.9 cm; SD, 2.9 cm) in bones (n = 33), liver (n = 26), soft tissues (n = 18), lung (n = 15) and abdomen (n = 14) were reviewed. The biopsy procedures were performed following injection of a mean of 255 MBq (SD, 74) FDG. Mean maximal standardized uptake value (SUV) of lesions was 8.8 (SD, 6.3). A systematic review of the histopathological results and outcomes was performed. Biopsies were positive for malignancy in 76 cases (71.7 %, 76/106) and for benign tissue in 30 cases (28.3 %, 30/106). Immediate results were considered adequate for 100 PET/CT biopsies (94.3 %, 100/106) requiring no further exploration, and for the six others (5.7 %, 6/106) benign diagnoses were confirmed after surgery (n = 4) or follow-up (n = 2). The consequent overall sensitivity and the diagnostic success of biopsy were therefore 100 %. No significant differences in terms of detection of malignancy were observed between the different locations. Lesions > 2 cm or with SUV > 4 were not significantly more likely to be malignant. Complications occurred after four biopsies (3.7 %, 4/106). Intra-procedural PET/CT guidance appears as a safe and effective method and allows high diagnostic success of percutaneous biopsies for metabolically active lesions. (orig.)

  3. Percutaneous CT-Guided Biopsy of C3 Vertebral Body: Modified Approach for an Old Procedure

    International Nuclear Information System (INIS)

    Pua, Uei; Chan, Stephen Yung-Wei

    2013-01-01

    Percutaneous biopsy of upper cervical vertebrae is challenging due to the various critical structures in the location and often requires difficult trajectory such as transoral or paramaxillary approaches. The purpose of this manuscript is to illustrate the utility of head rotation in creating a potential space for direct percutaneous access to C3 vertebral body for safe biopsy.

  4. Percutaneous CT-Guided Biopsy of C3 Vertebral Body: Modified Approach for an Old Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei, E-mail: druei@yahoo.com [Tan Tock Seng Hospital, Department of Diagnostic Radiology (Singapore); Chan, Stephen Yung-Wei [Tan Tock Seng Hospital, Department of Anaesthesiology, Intensive Care and Pain Medicine (Singapore)

    2013-06-15

    Percutaneous biopsy of upper cervical vertebrae is challenging due to the various critical structures in the location and often requires difficult trajectory such as transoral or paramaxillary approaches. The purpose of this manuscript is to illustrate the utility of head rotation in creating a potential space for direct percutaneous access to C3 vertebral body for safe biopsy.

  5. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage.

    Science.gov (United States)

    Biron, Vincent L; Kurien, George; Dziegielewski, Peter; Barber, Brittany; Seikaly, Hadi

    2013-02-26

    Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. To compare I&D vs USD of well-defined DNAs, using a randomized controlled clinical trial design. The primary outcome measure was effectiveness (length of hospital stay (LOHS) and safety), and the secondary outcome measure was overall cost to the healthcare system. Patients presenting to the University of Alberta Emergency Department with a well-defined deep neck space abscess were recruited in the study. Patients were randomized to surgical or US-guided drainage, placed on intravenous antibiotics and admitted with airway precautions. Following drainage with either intervention, abscess collections were cultured and drains were left in place until discharge. Seventeen patients were recruited in the study. We found a significant difference in mean LOHS between patients who underwent USD (3.1 days) vs I&D (5.2 days). We identified significant cost savings associated with USD with a 41% cost reduction in comparison to I&D. USD drainage of deep neck space abscesses in a certain patient population is effective, safe, and results in a significant cost savings to the healthcare system.

  6. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  7. Malignant Tumours Mimicking Complicated Appendicitis and Discovered upon Follow-Up after Percutaneous Drainage: A Case of Two Patients

    Directory of Open Access Journals (Sweden)

    Sharandran Chandra Mohan

    2017-01-01

    Full Text Available The conservative management of periappendiceal abscesses is gaining favour due to decreased morbidity and improved clinical outcomes for patients. Occasionally however an abscess can mask underlying sinister pathology. In this article, we highlight two cases of appendiceal adenocarcinoma that were initially diagnosed as periappendiceal abscesses and managed conservatively with percutaneous drainage. We also discuss clinical and imaging features that may assist with identifying a hidden malignancy when presented in these situations.

  8. CT-guided core needle biopsy of mediastinal nodes through a transpulmonary approach: retrospective analysis of the procedures conducted over six years.

    Science.gov (United States)

    Yin, Zhongyuan; Liang, Zhiwen; Li, Pengcheng; Wang, Qiong

    2017-08-01

    To retrospectively evaluate the diagnostic performance and complications of a CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach. From January 2009 to December 2014, we used a coaxial positioning system and an 18G cutting-type biopsy device to perform CT-guided percutaneous transpulmonary needle biopsies of mediastinal nodes for 127 patients. The diagnostic performance, complication rate, influencing factors, distribution of mediastinal nodes and pathological diagnoses were investigated. Among 127 patients, pathologic analyses showed that all of the biopsies were technically successful. The sensitivity, specificity, positive predictive value, and negative predictive value were all 100%. As for complications, the ratios for pneumothorax and hemoptysis were 33.9% and 4.7%, respectively. Multivariate analyses revealed that the distance from the pleura to the target lesion (P = 0.008) and the numbers of visceral pleura injuries (P = 0.006) were the two most significant risk factors for pneumothorax, and that the distance from the pleura to the target lesion (P = 0.004) was the most significant risk factor for hemoptysis. CT-guided core needle cutting biopsy of mediastinal nodes through a transpulmonary approach is a safe and efficient diagnostic method. • CT-guided core needle biopsy is an accurate technique for diagnosing mediastinal nodes. • The rates of complications are similar to those for pulmonary lesion biopsy. • Pneumothorax risk factors include distance from pleura to target lesion and number of visceral pleura. • Distance from pleura to target lesion is the risk factor for hemoptysis. • CT-guided core needle biopsy is an important diagnostic method for mediastinal nodes.

  9. Percutaneous debridement of complex pyogenic liver abscesses: technique and results

    International Nuclear Information System (INIS)

    Morettin, L.B.

    1992-01-01

    The author's approach and technique in the treatment of complex liver abscesses that persisted or recurred following percutaneous drainage are described. Six patients were treated by percutaneous debridement utilizing an instrument specifically constructed for that purpose. Four patients were chronically ill but stable. Two patients were septic, hypotensive and considered life threatened. All patients had primary pyogenic abscesses. Four had demonstrated mixed bacterial flora consisting of E. coli, Klebsiella, Proteus and gram-positive cocci and two were caused by E. coli only. In all cases a contrast-enhanced CT of the abdomen revealed multiloculated or septated abscesses containing large central debris and peripheral shell or halo of compromised hepatic parenchyma. Debridement was successful in all cases resulting in complete healing in 4-12 days. Follow-up for periods of between 1 and 4.5 years revealed no recurrences. Three cases of infected tumors of the liver were referred for treatment. CT findings in these cases demonstrated a well-developed external capsule and internal septations and the absence of a surrounding halo of compromised parenchyma distinguishes them from primary abscesses. This preliminary experience allows the conclusion that percutaneous debridement of pyogenic liver abscesses can be safely performed, can be curative in selected patients with chronic abscesses and may be life-safing in critically ill and life-threatened patients. (orig.)

  10. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    Energy Technology Data Exchange (ETDEWEB)

    Tantawy, Wahid H., E-mail: tantawyw@yahoo.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); El-Gemeie, Emad H. [Pathology Department, National Cancer Institute, Fom El Khalige Faculty of Medicine, Cairo University (Egypt); Ibrahim, Ahmed S., E-mail: asibrahima@gmail.com [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt); Mohamed, Mona A. [Radiology Department, Faculty of Medicine, Ain Shams University, Egypt Abbassyia square, Cairo (Egypt)

    2012-10-15

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening.

  11. Extrapleural paravertebral CT guided fine needle biopsy of subcarinal lymph nodes

    International Nuclear Information System (INIS)

    Tantawy, Wahid H.; El-Gemeie, Emad H.; Ibrahim, Ahmed S.; Mohamed, Mona A.

    2012-01-01

    Purpose: To report our experience in CT guided extrapleural paravertebral subcarinal lymph biopsy using a thin 25 gauge (25 G) thin needle without the need of injection of saline to widen the mediastinum. Materials and methods: Biopsy was performed using a 25 G needle which was advanced lateral to the vertebral body between the endothoracic fascia and the parietal pleura to gain access to subcarinal lymph nodes. One hundred and forty one patients were included in the study (74 females, 57 males). No artificial widening of the mediastinum using saline injection was required. The study was performed in the presence of a cytopathologist; sensitivity and specificity rates were calculated. Complications were documented for each case especially for pneumothorax and haemorrhage. Results: Cytopathological diagnosis was reached in all cases. All re-aspirations were done in the same session to reach a primary diagnosis at the time of the biopsy. Imunophenotyping study was done in 94 cases to confirm the primary diagnosis and to classify the malignant lesions. No pneumothorax was encountered. Small haematomas were noted in 5 cases (3.5%). Cytopathology showed a sensitivity of 97.2% and specificity of 100%. By adding immunophenotyping a 100% sensitivity and specificity was achieved. Conclusion: Fine needle aspiration cytology (FNAC) using a 25 gauge needle for subcarinal lymph nodes via a percutaneous extrapleural paravertebral CT guided approach is a safe, minimally invasive, and tolerable procedure yielding a high sensitivity and specificity rates without the need of artificial widening

  12. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  13. High Retention and Safety of Percutaneously Implanted Endovascular Embolization Coils as Fiducial Markers for Image-Guided Stereotactic Ablative Radiotherapy of Pulmonary Tumors

    International Nuclear Information System (INIS)

    Hong, Julian C.; Yu Yao; Rao, Aarti K.; Dieterich, Sonja; Maxim, Peter G.; Le, Quynh-Thu; Diehn, Maximilian; Sze, Daniel Y.; Kothary, Nishita; Loo, Billy W.

    2011-01-01

    Purpose: To compare the retention rates of two types of implanted fiducial markers for stereotactic ablative radiotherapy (SABR) of pulmonary tumors, smooth cylindrical gold 'seed' markers ('seeds') and platinum endovascular embolization coils ('coils'), and to compare the complication rates associated with the respective implantation procedures. Methods and Materials: We retrospectively analyzed the retention of percutaneously implanted markers in 54 consecutive patients between January 2004 and June 2009. A total of 270 markers (129 seeds, 141 coils) were implanted in or around 60 pulmonary tumors over 59 procedures. Markers were implanted using a percutaneous approach under computed tomography (CT) guidance. Postimplantation and follow-up imaging studies were analyzed to score marker retention relative to the number of markers implanted. Markers remaining near the tumor were scored as retained. Markers in a distant location (e.g., pleural space) were scored as lost. CT imaging artifacts near markers were quantified on radiation therapy planning scans. Results: Immediately after implantation, 140 of 141 coils (99.3%) were retained, compared to 110 of 129 seeds (85.3%); the difference was highly significant (p < 0.0001). Of the total number of lost markers, 45% were reported lost during implantation, but 55% were lost immediately afterwards. No additional markers were lost on longer-term follow-up. Implanted lesions were peripherally located for both seeds (mean distance, 0.33 cm from pleural surface) and coils (0.34 cm) (p = 0.96). Incidences of all pneumothorax (including asymptomatic) and pneumothorax requiring chest tube placement were lower in implantation of coils (23% and 3%, respectively) vs. seeds (54% and 29%, respectively; p = 0.02 and 0.01). The degree of CT artifact was similar between marker types. Conclusions: Retention of CT-guided percutaneously implanted coils is significantly better than that of seed markers. Furthermore, implanting coils is at

  14. Risk Factors for Immediate and Delayed-Onset Fever After Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Lucatelli, Pierleone, E-mail: pierleone.lucatelli@gmail.com [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Corradini, Stefano Ginanni, E-mail: stefano.corradini@uniroma1.it [Sapienza University of Rome, Gastroenterology Division, Department of Clinical Medicine (Italy); Corona, Mario, E-mail: mario.corona@uniroma1.it; Corradini, Luca Ginanni, E-mail: lucagino@hotmail.it; Cirelli, Carlo, E-mail: dottcirelli@gmail.com [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Saba, Luca, E-mail: lucasabamd@gmail.com [Azienda Ospedaliero Universitaria (A.O.U.) of Cagliari-Polo di Monserrato, Department of Medical Imaging (Italy); Poli, Edoardo, E-mail: edoardo.poli88@gmail.com [Sapienza University of Rome, Gastroenterology Division, Department of Clinical Medicine (Italy); Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy); Wang, Haofan, E-mail: wanghaof@mail.sysu.edu.cn [Department of Vascular Interventional Radiology of the 3rd Affiliated Hospital of Sun Yat-sen University (China); Bezzi, Mario, E-mail: mario.bezzi@uniroma1.it; Catalano, Carlo, E-mail: carlo.catalano@uniroma1.it [Sapienza University of Rome, Vascular and Interventional Radiology Unit, Department of Radiological, Oncological and Anatomo-pathological Sciences (Italy)

    2016-05-15

    ObjectivesTo prospectively investigate the pre and intra-procedural risk factors for immediate (IF) and delayed-onset (DOF) fever development after percutaneous transhepatic biliary drainage (PTBD).MethodsInstitutional review board approval and informed patient consent were obtained. Between February 2013 and February 2014, 97 afebrile patients (77 at the Sapienza University of Rome, Italy and 20 at the Sun Yat-sen University of Guangzhou, China) with benign (n = 31) and malignant (n = 66) indications for a first PTBD were prospectively enrolled. Thirty pre- and intra-procedural clinical/radiological characteristics, including the amount of contrast media injected prior to PTBD placement, were collected in relation to the development of IF (within 24 h) or DOF (after 24 h). Fever was defined as ≥37.5 °C. Binary logistic regression analysis was used to assess independent associations with IF and DOF.ResultsFourteen (14.4 %) patients developed IF and 17 (17.5 %) developed DOF. At multivariable analysis, IF was associated with pre-procedural absence of intrahepatic bile duct dilatation (OR 63.359; 95 % CI 2.658–1510.055; P = 0.010) and low INR (OR 4.7 × 10{sup −4}; 95 % CI 0.000–0.376; P = 0.025), while DOF was associated with unsatisfactory biliary drainage at the end of PTBD (OR 4.571; 95 % CI 1.161–17.992; P = 0.030).ConclusionsThe amount of contrast injected is not associated with post-PTBD fever development. Unsatisfactory biliary drainage at the end of PTBD is associated with DOF, suggesting that complete biliary tree decompression should be pursued within the first PTBD. Patients with unsatisfactory drainage and those with the absence of pre-procedural intrahepatic bile duct dilatation, which is associated with IF, require tailored post-PTBD management.

  15. Risk Factors for Immediate and Delayed-Onset Fever After Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Lucatelli, Pierleone; Corradini, Stefano Ginanni; Corona, Mario; Corradini, Luca Ginanni; Cirelli, Carlo; Saba, Luca; Poli, Edoardo; Fanelli, Fabrizio; Wang, Haofan; Bezzi, Mario; Catalano, Carlo

    2016-01-01

    ObjectivesTo prospectively investigate the pre and intra-procedural risk factors for immediate (IF) and delayed-onset (DOF) fever development after percutaneous transhepatic biliary drainage (PTBD).MethodsInstitutional review board approval and informed patient consent were obtained. Between February 2013 and February 2014, 97 afebrile patients (77 at the Sapienza University of Rome, Italy and 20 at the Sun Yat-sen University of Guangzhou, China) with benign (n = 31) and malignant (n = 66) indications for a first PTBD were prospectively enrolled. Thirty pre- and intra-procedural clinical/radiological characteristics, including the amount of contrast media injected prior to PTBD placement, were collected in relation to the development of IF (within 24 h) or DOF (after 24 h). Fever was defined as ≥37.5 °C. Binary logistic regression analysis was used to assess independent associations with IF and DOF.ResultsFourteen (14.4 %) patients developed IF and 17 (17.5 %) developed DOF. At multivariable analysis, IF was associated with pre-procedural absence of intrahepatic bile duct dilatation (OR 63.359; 95 % CI 2.658–1510.055; P = 0.010) and low INR (OR 4.7 × 10"−"4; 95 % CI 0.000–0.376; P = 0.025), while DOF was associated with unsatisfactory biliary drainage at the end of PTBD (OR 4.571; 95 % CI 1.161–17.992; P = 0.030).ConclusionsThe amount of contrast injected is not associated with post-PTBD fever development. Unsatisfactory biliary drainage at the end of PTBD is associated with DOF, suggesting that complete biliary tree decompression should be pursued within the first PTBD. Patients with unsatisfactory drainage and those with the absence of pre-procedural intrahepatic bile duct dilatation, which is associated with IF, require tailored post-PTBD management.

  16. Pulmonary emphysema is a predictor of pneumothorax after CT-guided transthoracic pulmonary biopsies of pulmonary nodules.

    Science.gov (United States)

    Lendeckel, Derik; Kromrey, Marie-Luise; Ittermann, Till; Schäfer, Sophia; Mensel, Birger; Kühn, Jens-Peter

    2017-01-01

    Pneumothoraces are the most frequently occurring complications of CT-guided percutaneous transthoracic pulmonary biopsies (PTPB). The aim of this study was to evaluate the influence of pre-diagnostic lung emphysema on the incidence and extent of pneumothoraces and to establish a risk stratification for the evaluation of the pre-procedure complication probability. CT-guided PTPB of 100 pre-selected patients (mean age 67.1±12.8 years) were retrospectively enrolled from a single center database of 235 PTPB performed between 2012-2014. Patients were grouped according to pneumothorax appearance directly after PTPB (group I: without pneumothorax, n = 50; group II: with pneumothorax, n = 50). Group II was further divided according to post-interventional treatment (group IIa: chest tube placement, n = 24; group IIb: conservative therapy, n = 26). For each patient pre-diagnostic percentage of emphysema was quantified using CT density analysis. Emphysema stages were compared between groups using bivariate analyses and multinomial logistic regression analyses. Emphysema percentage was significantly associated with the occurrence of post-interventional pneumothorax (p = 0.006). Adjusted for potential confounders (age, gender, lesion size and length of interventional pathway) the study yielded an OR of 1.07 (p = 0.042). Absolute risk of pneumothorax increased from 43.4% at an emphysema rate of 5% to 73.8% at 25%. No differences could be seen in patients with pneumothorax between percentage of emphysema and mode of therapy (p = 0.721). The rate of lung emphysema is proportionally related to the incidence of pneumothorax after CT-guided PTPB and allows pre-interventional risk stratification. There is no association between stage of emphysema and post-interventional requirement of chest tube placement.

  17. Percutaneous Vertebroplasty for Compression Fracture: Analysis of Vertebral Body Volume by CT Volumetry

    International Nuclear Information System (INIS)

    Komemushi, A.; Tanigawa, N.; Kariya, S.; Kojima, H.; Shomura, Y.; Sawada, S.

    2005-01-01

    Purpose: To evaluate the relationships between volume of vertebral bodies with compression fracture (measured by CT volumetry) before percutaneous vertebroplasty, the amount of bone cement injected, and the effect of treatment. Material and Methods: We examined 49 consecutive patients, with 104 vertebral body compression fractures, who underwent percutaneous injection of bone cement. Vertebral body volume was measured by CT volumetry. The patient's pain level was assessed using a visual analog scale (VAS) before and after the procedure. Improvement in VAS was defined as the decrease in VAS after the procedure. Relationships between vertebral body volume, the amount of bone cement, and the effect of treatment were evaluated using Pearson's correlation coefficient test. Results: Average vertebral body volume was 26.3 ±8.1 cm 3 ; average amount of bone cement was 3.2 ±1.1 ml; and average improvement in VAS was 4.9 ±2.7. The vertebral body volume was greater if a larger amount of bone cement was injected. There was a significant positive correlation between vertebral body volume and amount of bone cement ( r ∼ 0.44; P <0.0001). However, there was no correlation between vertebral body volume and improvement in VAS, or between amount of bone cement and improvement in VAS. Conclusion: In percutaneous vertebroplasty for vertebral body compression fracture, there is a positive correlation between vertebral body volume and amount of bone cement, but improvement in VAS does not correlate with vertebral body volume or amount of bone cement

  18. CT-Guided Superior Vena Cava Puncture: A Solution to Re-Establishing Access in Haemodialysis-Related Central Venous Occlusion Refractory to Conventional Endovascular Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Khalifa, Mohamed, E-mail: mkhalifa@nhs.net; Patel, Neeral R., E-mail: neeral.patel06@gmail.com; Moser, Steven, E-mail: steven.moser@imperial.nhs.uk [Hammersmith Hospital, Department of Radiology, Imperial College Healthcare NHS Trust (United Kingdom)

    2016-04-15

    PurposeThe purpose of this technical note is to demonstrate the novel use of CT-guided superior vena cava (SVC) puncture and subsequent tunnelled haemodialysis (HD) line placement in end-stage renal failure (ESRF) patients with central venous obstruction refractory to conventional percutaneous venoplasty (PTV) and wire transgression, thereby allowing resumption of HD.MethodsThree successive ESRF patients underwent CT-guided SVC puncture with subsequent tract recanalisation. Ultrasound-guided puncture of the right internal jugular vein was performed, the needle advanced to the patent SVC under CT guidance, with subsequent insertion of a stabilisation guidewire. Following appropriate tract angioplasty, twin-tunnelled HD catheters were inserted and HD resumed.ResultsNo immediate complications were identified. There was resumption of HD in all three patients with a 100 % success rate. One patient’s HD catheter remained in use for 2 years post-procedure, and another remains functional 1 year to the present day. One patient died 2 weeks after the procedure due to pancreatitis-related abdominal sepsis unrelated to the Tesio lines.ConclusionCT-guided SVC puncture and tunnelled HD line insertion in HD-related central venous occlusion (CVO) refractory to conventional recanalisation options can be performed safely, requires no extra equipment and lies within the skill set and resources of most interventional radiology departments involved in the management of HD patients.

  19. CT scan-guided percutaneous osteosynthesis of a complex, multifocal fracture of the pelvic girdle in a 14-year-old adolescent

    Energy Technology Data Exchange (ETDEWEB)

    Gagne, Pierre-Thomas; Bertrand, Anne-Sophie; Caudal, Amandine; El Hayek, Tony; Amoretti, Nicolas [Centre Hospitalier Universitaire de Nice, Nice (France)

    2014-08-15

    We report on a 14-year-old girl with minimally displaced pelvic girdle and acetabular roof fracture following motor vehicle trauma, treated percutaneously under CT and C-arm fluoroscopic guidance by an interventional radiologist. After informed consent from the patient's parents, under surgical aseptic conditions and under general anesthesia, three screws were positioned adequately under dual guidance by a radiologist and without immediate or long-term complication. The patient was mobilized 48 h after the procedure and resumed normal activities after 1 month. Even though the technique has been described before on adults, to our knowledge this is the first time it has been described on a pediatric patient. (orig.)

  20. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  1. Intra-biliary contrast-enhanced ultrasound for evaluating biliary obstruction during percutaneous transhepatic biliary drainage: A preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Er-jiao [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Zheng, Rong-qin, E-mail: zhengrq@mail.sysu.edu.cn [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China); Su, Zhong-zhen; Li, Kai; Ren, Jie; Guo, Huan-yi [Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, No. 600 Tianhe Road, Guangzhou 510630 (China)

    2012-12-15

    Objectives: The aimed of this study was to investigate the value of intra-biliary contrast-enhanced ultrasound (IB-CEUS) for evaluating biliary obstruction during percutaneous transhepatic biliary drainage (PTBD). Materials and methods: 80 patients with obstructive jaundice who underwent IB-CEUS during PTBD were enrolled. The diluted ultrasound contrast agent was injected via the drainage catheter to perform IB-CEUS. Both conventional ultrasound and IB-CEUS were used to detect the tips of the drainage catheters and to compare the detection rates of the tips. The obstructive level and degree of biliary tract were evaluated by IB-CEUS. Fluoroscopic cholangiography (FC) and computer tomography cholangiography (CTC) were taken as standard reference for comparison. Results: Conventional ultrasound displayed only 43 tips (43/80, 53.8%) of the drainage catheters within the bile ducts while IB-CEUS identified all 80 tips (80/80, 100%) of the drainage catheters including 4 of them out of the bile duct (P < 0.001). IB-CEUS made correct diagnosis in 44 patients with intrahepatic and 36 patients with extrahepatic biliary obstructions. IB-CEUS accurately demonstrated complete obstruction in 56 patients and incomplete obstruction in 21 patients. There were 3 patients with incomplete obstruction misdiagnosed to be complete obstruction by IB-CEUS. The diagnostic accuracy of biliary obstruction degree was 96.3% (77/80). Conclusion: IB-CEUS could improve the visualization of the drainage catheters and evaluate the biliary obstructive level and degree during PTBD. IB-CEUS may be the potential substitute to FC in the PTBD procedure.

  2. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  3. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  4. Percutaneous Facet Screw Fixation in the Treatment of Symptomatic Recurrent Lumbar Facet Joint Cyst: A New Technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas, E-mail: amorettinicolas@yahoo.fr; Gallo, Giacomo, E-mail: giacomo.gallo83@gmail.com; Bertrand, Anne-Sophie, E-mail: asbertrand3@hotmail.com [Centre Hospitalier Universitaire de Nice (France); Bard, Robert L., E-mail: rbard@cancerscan.com [New York Medical College (United States); Kelekis, Alexis, E-mail: akelekis@med.uoa.gr [University General Hospital “ATTIKON” (Greece)

    2016-01-15

    We present a case of percutaneous treatment of symptomatic recurrent lumbar facet joint cyst resistant to all medical treatments including facet joint steroid injection. Percutaneous transfacet fixation was then performed at L4–L5 level with a cannulated screw using CT and fluoroscopy guidance. The procedure time was 30 min. Using the visual analog scale (VAS), pain decreased from 9.5, preoperatively, to 0 after the procedure. At 6-month follow-up, an asymptomatic cystic recurrence was observed, which further reduced at the 1-year follow-up. Pain remained stable (VAS at 0) during all follow-ups. CT- and fluoroscopy-guided percutaneous cyst rupture associated with facet screw fixation could be an alternative to surgery in patients suffering from a symptomatic recurrent lumbar facet joint cyst.

  5. Location of pulmonary modules prior to video thoracoscopic surgery by CT-guided hook wire placement: Preliminary study

    International Nuclear Information System (INIS)

    Ferreiras, J.; Salmeron, I.; Bustos Garcia de Castro, A.; Hernando, F.; Gomez, A.; Torres, A.

    1996-01-01

    Despite the efficacy of computerized tomography (CT) or radiologically-guided percutaneous biopsy and that offluoroscopically-guided trans bronchial biopsy in characterizing pulmonary nodules, it is not always possible to determine the etiology using these techniques, making it necessary to resort to thoracotomy. Recent developments in endoscopicsurgery equipment and the availability of advance video imaging technology have extended the indications for both diagnostic and therapeutic thoracoscopy. Thus, a number of procedures that previously could only be performed bymeans of thoracotomy, such as resection of peripheral pulmonary nodules, can nowbe carried out by means of video thoracoscopic (VT) surgery. Palpation orvisual location of pulmonary nodules by thoracoscopy is essential but is not always possible when the nodules measure less than 20 mm or when their location is not subpleural. In such cases, a procedure for their prior location is useful. In eight patients with pulmonary nodules who were to undergo subsequent VT surgery, the attempt was made to locate the nodules by CT-guided placementof a hook wire, similar to that employed in breast, and methylene blue injection. The hook wire was correctly introduced without significant complications in all eight cases. The eight nodules were successfully resected during the thoracoscopic procedure, in which the hook wire and methylene blue staining were of great assistance. In certain cases, the location of pulmonary nodules by means of CT-guidehook wire placement and methylene blue injection allows the video thoracoscopic resection of lesions of difficult access. (Author)

  6. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    International Nuclear Information System (INIS)

    Koethe, Yilun; Xu, Sheng; Velusamy, Gnanasekar; Wood, Bradford J.; Venkatesan, Aradhana M.

    2014-01-01

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  7. Accuracy and efficacy of percutaneous biopsy and ablation using robotic assistance under computed tomography guidance: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Koethe, Yilun [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Duke University School of Medicine, Durham, NC (United States); Xu, Sheng [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); Velusamy, Gnanasekar [Perfint Healthcare Pvt. Ltd., Chennai (India); Wood, Bradford J. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); Venkatesan, Aradhana M. [National Institutes of Health, Center for Interventional Oncology, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States); National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, NIH Clinical Center, Bethesda, MD (United States)

    2014-03-15

    To compare the accuracy of a robotic interventional radiologist (IR) assistance platform with a standard freehand technique for computed-tomography (CT)-guided biopsy and simulated radiofrequency ablation (RFA). The accuracy of freehand single-pass needle insertions into abdominal phantoms was compared with insertions facilitated with the use of a robotic assistance platform (n = 20 each). Post-procedural CTs were analysed for needle placement error. Percutaneous RFA was simulated by sequentially placing five 17-gauge needle introducers into 5-cm diameter masses (n = 5) embedded within an abdominal phantom. Simulated ablations were planned based on pre-procedural CT, before multi-probe placement was executed freehand. Multi-probe placement was then performed on the same 5-cm mass using the ablation planning software and robotic assistance. Post-procedural CTs were analysed to determine the percentage of untreated residual target. Mean needle tip-to-target errors were reduced with use of the IR assistance platform (both P < 0.0001). Reduced percentage residual tumour was observed with treatment planning (P = 0.02). Improved needle accuracy and optimised probe geometry are observed during simulated CT-guided biopsy and percutaneous ablation with use of a robotic IR assistance platform. This technology may be useful for clinical CT-guided biopsy and RFA, when accuracy may have an impact on outcome. (orig.)

  8. The study protocol for a non-randomized controlled clinical trial using a genotype-guided strategy in a dataset of patients who undergone percutaneous coronary intervention with stent

    Directory of Open Access Journals (Sweden)

    Cristina Lucía Dávila-Fajardo

    2017-02-01

    Full Text Available This article contains data related to the research article entitled “Results of genotype–guided antiplatelet therapy in patients undergone percutaneous coronary intervention with stent” (J. Sánchez-Ramos, C.L. Dávila-Fajardo, P. Toledo Frías, X. Díaz Villamarín, L.J. Martínez-González, S. Martínez Huertas, F. Burillo Gómez, J. Caballero Borrego, A. Bautista Pavés, M.C. Marín Guzmán, J.A. Ramirez Hernández, C. Correa Vilches, J. Cabeza Barrera, 2016 (1. This data article reports, for the first time, about the non-randomized clinical trial protocol that check if CYP2C19/ABCB1 genotype–guided strategy in which the choice of antiplatelet therapy is based on the genetic test, reduces the rates of cardiovascular events and bleeding compared to a non-tailored strategy in patients undergone percutaneous coronary intervention (PCI with stent. The data included in this article are: design and setting of the study, study population, inclusion and exclusion criteria, definition of the intervention, objectives, variables (baseline characteristics and during the follow-up, study procedures, collection and treatment of the biological sample, genotyping, withdrawal criteria, sample size, statistic analysis, ethical aspects, information sheet and consent form. The authors confirm that this study has been registered in Eudra CT (Eudra CT: 2016-001294-33.

  9. Percutaneous management of urolithiasis during pregnancy.

    Science.gov (United States)

    Kavoussi, L R; Albala, D M; Basler, J W; Apte, S; Clayman, R V

    1992-09-01

    A total of 6 pregnant women with obstructing urinary calculi was managed by percutaneous nephrostomy drainage placed under ultrasound guidance with the patient under local anesthesia. All patients initially had relief of acute obstruction. However, occlusion of the percutaneous nephrostomy tubes with debris necessitated tube changes in 5 of 6 patients. In 2 patients recurrent nephrostomy tube obstruction, fever and pain led to percutaneous stone removal during pregnancy. In the remaining 4 patients the nephrostomy tubes were left indwelling through delivery. During the postpartum period 3 patients successfully underwent ureteroscopic stone extraction and 1 passed the stone spontaneously. Bacteriuria developed in each patient despite the use of preventive antibiotics. All 6 women had uncomplicated vaginal deliveries of healthy newborns and are currently asymptomatic with no evidence of obstruction. Percutaneous drainage of an acutely obstructed kidney in a pregnant woman is an effective temporizing alternative to ureteral stent placement until definitive treatment can be performed.

  10. Efficacy of Ablation Therapy for Secondary Hyperparathyroidism by Ultrasound Guided Percutaneous Thermoablation.

    Science.gov (United States)

    Zhao, Junfeng; Qian, Linxue; Zu, Yuan; Wei, Ying; Hu, Xiangdong

    2016-05-01

    The objective of this study was to explore the value of ultrasound-guided percutaneous microwave thermoablation to treat secondary hyperparathyroidism (SHPT). One hundred and thirty-eight parathyroid glands from 56 patients with SHPT were ablated in this study. All the parathyroid glands were evaluated by real-time contrast-enhanced ultrasound before, during and after ablation. Changes in serum parathyroid hormone (sPTH) levels were measured before treatment and at 1 h, 1 wk, 1 mo and 6 mo after thermoablation treatment. All 56 cases had a 1-mo follow-up, and 34 cases had a 6-mo follow-up. The sPTH level of the 54 cases 1 mo after ablation was significantly lower than that before (p 0.05). Ultrasound-guided percutaneous microwave thermoablation is a feasible and effective non-surgical alternative treatment for SHPT patients. Copyright © 2016. Published by Elsevier Inc.

  11. Ultrasound guided percutaneous removal of wooden foreign bodies in the extremities with hydro-dissection technique

    Energy Technology Data Exchange (ETDEWEB)

    Park, HeeJin; Lee, So Yeon; Chung, Eun Chul; Rho, Myung Ho [Dept. of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Lee, Sung Moon; Son, Eun Seok [Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Sun Joo [Dept. of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan (Korea, Republic of)

    2015-12-15

    We described the technique of ultrasound (US)-guided percutaneous removal of the foreign bodies (FB) with hydro-dissection in the radiologic department and presented video files of several cases.Four patients referred to the radiology department for US evaluation and US-guided percutaneous removal of the FBs in the upper and lower extremities between November, 2006 and November, 2013 were included in this study. The procedures started with US evaluation for the exact location and shape of the FB. A 5 mm-sized skin incision was made at the site of the nearest point from the FB where no passing arteries or tendons were present. We adopted a hydro dissection technique to separate the FB from adjacent tissue using a 2% lidocaine solution. Injected anesthetics detached the FBs from surrounding tissue and thereby facilitated removal. After the tip of the mosquito forceps reached the FB, the wooden FBs were removed. The mean time required for the entire procedure was approximately 20 minutes. There were no significant complications during the US-guided removal or long-term complications after the procedure. All 4 FBs were successfully removed from the soft tissue under US guidance. Ultrasound-guided percutaneous removal of the FBs with hydro-dissection in the radiology department is a less invasive and safe method over surgical removal in the operating room. Additionally, the use of a guide wire and serial dilator may help minimize soft tissue injury and facilitate the introduction of forceps.

  12. Soft-Tissue-Anchored Transcutaneous Port for Long-Term Percutaneous Transhepatic Biliary Drainage

    International Nuclear Information System (INIS)

    Nyman, Rickard; Ekloef, Hampus; Eriksson, Lars-Gunnar; Karlsson, Britt-Marie; Rasmussen, Ib; Lundgren, Dan; Thomsen, Peter

    2005-01-01

    Purpose. A transcutaneous port (T-port) has been developed allowing easy exchange of a catheter, which was fixed inside the device, using the Seldinger technique. The objective of the study was to test the T-port in patients who had percutaneous transhepatic biliary drainage (PTBD). Methods. The T-port, made of titanium, was implanted using local anesthesia in 11 patients (mean age 65 years, range 52-85 years) with biliary duct obstruction (7 malignant and 4 benign strictures). The subcutaneous part of the T-port consisted of a flange with several perforations allowing ingrowth of connective tissue. The T-port allowed catheter sizes of 10 and 12 Fr. Results. All wounds healed uneventfully and were followed by a stable period without signs of pronounced inflammation or infection. It was easy to open the port and to exchange the drainage tube. The patient's quality of life was considerably improved even though several patients had problems with repeated bile leakage due to frequent recurrent obstructions of the tubes. The ports were implanted for a mean time of 9 months (range 2-21 months). Histologic examination in four cases showed that the port was well integrated into the soft tissue. Tilting of the T-port in two cases led to perforation of the skin by the subcutaneous part of the ports, which were removed after 7 and 8 months. Conclusion. The T-port served as an excellent external access to the biliary ducts. The drainage tubes were well fixed within the ports. The quality of life of the patients was considerably improved. Together with improved aesthetic appearance they found it easier to conduct normal daily activities and personal care. However, the problem of recurrent catheter obstruction remained unsolved

  13. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  14. Endovascular treatment of iliofemoral deep vein thrombosis in pregnancy using US-guided percutaneous aspiration thrombectomy.

    Science.gov (United States)

    Gedikoglu, Murat; Oguzkurt, Levent

    2017-01-01

    We aimed to describe ultrasonography (US)-guided percutaneous aspiration thrombectomy in pregnant women with iliofemoral deep vein thrombosis. This study included nine pregnant women with acute and subacute iliofemoral deep vein thrombosis, who were severe symptomatic cases with massive swelling and pain of the leg. Patients were excluded from the study if they had only femoropopliteal deep vein thrombosis or mild symptoms of deep vein thrombosis. US-guided percutaneous aspiration thrombectomy was applied to achieve thrombus removal and uninterrupted venous flow. The treatment was considered successful if there was adequate venous patency and symptomatic relief. Complete or significant thrombus removal and uninterrupted venous flow from the puncture site up to the iliac veins were achieved in all patients at first intervention. Complete relief of leg pain was achieved immediately in seven patients (77.8%). Two patients (22.2%) had a recurrence of thrombosis in the first week postintervention. One of them underwent a second intervention, where percutaneous aspiration thrombectomy was performed again with successful removal of thrombus and establishment of in line flow. Two patients were lost to follow-up after birth. None of the remaining seven patients had rethrombosis throughout the postpartum period. Symptomatic relief was detected clinically in these patients. Endovascular treatment with US-guided percutaneous aspiration thrombectomy can be considered as a safe and effective way to remove thrombus from the deep veins in pregnant women with acute and subacute iliofemoral deep vein thrombosis.

  15. Nonfluoroscopic endoscopic ultrasound-guided transmural drainage of pancreatic pseudocysts at atypical locations

    Directory of Open Access Journals (Sweden)

    Surinder Singh Rana

    2016-01-01

    Full Text Available Background: Pancreatic pseudocysts (PP at atypical locations are a therapeutic challenge and are usually managed surgically. Objective: We evaluated safety and efficacy of nonfluoroscopic endoscopic ultrasound (NF-EUS-guided transmural drainage in the management of PP at atypical locations. Patients and Methods: Retrospective analysis of 11 patients (all males; age range: 28-46 years with PP at atypical locations who were treated with NF-EUS-guided transmural drainage during the last 18 months was done. Results: Four patients had intra/peri-splenic, three patients had mediastinal, three patients had intrahepatic, and one patient had renal PP. Nine patients had chronic pancreatitis whereas two patients had acute pancreatitis. Alcohol was the etiology of pancreatitis in ten patients. The size of PP ranged from 4 to 10 cm. All patients had abdominal pain, and two patients had fever whereas one patient with mediastinal PP also had dysphagia. NF-EUS-guided transmural drainage could be done successfully in all patients. 7 Fr transmural stent (s was/were placed in six patients whereas single-time complete aspiration of PP was done in five patients. On endoscopic retrograde pancreatography, six patients had partial duct disruption whereas five patients had complete disruption. Bridging transpapillary stent (5 Fr was placed in all patients with partial disruption. All PP healed in 10/11 (91% patients within 2-4 weeks, and there has been no recurrence in 9 of these patients during a follow-up period of 4-18 months. One patient with splenic PP needed surgery for gastrointestinal bleed. Conclusion: PP at atypical locations can be effectively and safely treated with NF-EUS-guided transmural drainage.

  16. Lumbar sympathectomy under CT guidance: therapeutic option in critical limb ischaemia

    International Nuclear Information System (INIS)

    Pieri, Stefano; Agresti, Paolo; Di Cesare, Fabio; Ricci, Guiseppe

    2005-01-01

    Purpose: Lumbar sympathectomy is a complementary therapeutic option for patients with severe peripheral vascular occlusive disease presenting rest pain or gangrene and not eligible for surgical revascularisation. Traditional surgical sympathectomy was widely used in the past. However, due to its invasive character, it has increasingly been replaced by percutaneous techniques and, in some recent cases, by laparoscopic procedures. Percutaneous lumbar sympathectomy is a safe, cost-effective and widely available treatment option. We report our experience on 19 patients subjected to percutaneous sympathectomy under CT guidance. Materials and methods: Between 1998 and 2000, 19 patients underwent percutaneous sympathectomy under CT guidance. All patients had severe vascular disease of the lower extremities (Fontaine stage IV), with rest pain and gangrene. They were not eligible for surgical revascularization. Phenol was injected at the level of L2 and L4 using two 22 G needles (15 cm long). Signs of interrupted sympathetic activity usually occur 2'-15' after the procedure with warmth and flushing and dryness of the lower extremities. Results: Percutaneous sympathectomy under CT guidance is a simple, safe and well-tolerated procedure with a low rate of complications. Of the 19 patients, 9 (47.3%) showed clinical improvement, whereas 5 experienced a worsening of ischaemia in the month immediately following the procedure. Discussion: Results suggest that percutaneous lumbar sympathectomy causes a sympathetic blockade in patients with advanced vascular disease of the limb. CT guidance ensures a high level of precision in drug dosing, thus lowering the risk of complications. Although the results are demoralizing. the impossibility of achieving surgical revascularisation in advanced peripheral arteriosclerosis enhances the role of Ct-guided percutaneous sympathectomy in relieving rest pain and healing ulcers in order to postpone the amputation [it

  17. Outcome of CT-guided vertebroplasty in outpatients with severe vertebral compression fractures

    International Nuclear Information System (INIS)

    Braun, Markus; Gevargez, Athour; Lange, Silke; Leeuwen, Peter van; Groenemeyer, Dietrich H.W.

    2008-01-01

    To determine the safety and efficacy of computed tomography (CT)/fluoroscopy-guided percutaneous vertebroplasty (PVP) for the treatment of painful severe osteoporotic compression fractures. In 26 patients with osteoporotic severe and non-severe compression fractures experiencing pain, 55 PVP were performed. Pain relief and improvement of function were estimated using the Visual Analog Scale (VAS), Pain Disability Index (PDI) and Hannover functional ability questionnaire (FFbH) at follow-up examinations at a median of 3 (1-31) days and 6.5 (1-18) months after PVP. Pain relief (VAS and PDI) was significant at first and second follow-up. The improvement of function (FFbH) was statistically significant at the second follow-up. Severity of the compression fractures did not influence these results. There were no clinical complications and no patient required follow-up surgery. PVP is a safe and effective treatment of pain even in severe osteoporotic vertebral body compression fractures. The advantages of CT-guidance in combination with fluoroscopy technique are a minimally invasive precise procedure with high visualization and with low risk, performed cost effective on out patient basis in local anesthesia, leading to an early recovery of individual independence. (orig.)

  18. Endoscopic Ultrasound Guided Rendezvous Drainage of Biliary Obstruction Using a New Flexible 19-Gauge Fine Needle Aspiration Needle.

    Science.gov (United States)

    Tang, Zhouwen; Igbinomwanhia, Efehi; Elhanafi, Sherif; Othman, Mohamed O

    2016-01-01

    Background and Aim. A successful endoscopic ultrasound guided rendezvous (EUS-RV) biliary drainage is dependent on accurate puncture of the bile duct and precise guide wire manipulation across the ampulla of Vater. We aim to study the feasibility of using a flexible 19-gauge fine aspiration needle in the performance of EUS-RV biliary drainage. Method. This is a retrospective case series of EUS-RV biliary drainage procedures at a single center. Patients who failed ERCP during the same session for benign or malignant biliary obstruction underwent EUS-RV using a flexible, nitinol covered, 19-gauge needle for biliary access and guide wire manipulation. Result. 24 patients underwent EUS-RV biliary drainage via extrahepatic access while 1 attempt was via intrahepatic access. The technical success rate was 80%, including 83.3% of cases via extrahepatic access. There was no significant difference in success rate of inpatient and outpatient procedures, benign or malignant indications, or type of guide wire used. Adverse events included mild pancreatitis (3 patients) and cholangitis (1 patient). Conclusion. A flexible 19-gauge needle for biliary access can be safe and effective when used to perform EUS-RV biliary drainage. Direct comparison between the nitinol needle and conventional metal needles in the performance of EUS guided biliary drainage is needed.

  19. Pericardial Tamponade Following CT-Guided Lung Biopsy

    International Nuclear Information System (INIS)

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-01-01

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  20. Long-term outcomes of percutaneous lumbar facet synovial cyst rupture

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Bos, Stijn A.; Torriani, Martin; Simeone, F.J.; Chang, Connie Y.; Pomerantz, Stuart R.; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2017-01-15

    To evaluate the therapeutic value, safety, and long-term clinical outcomes of percutaneous lumbar facet synovial cyst (LFSC) rupture. Our study was institutional review board (IRB)-approved and Health Insurance Portability and Accountability Act (HIPAA)-compliant. The study group comprised 71 patients (44 women, mean age: 65 ± 17 years) who underwent CT- or fluoroscopy-guided percutaneous LFSC rupture. The technical success of LFSC rupture, the long-term clinical outcome, including repeat procedures or surgery, and imaging findings on MRI and CT were recorded. Seventy-nine LFSC ruptures were performed in 71 patients. CT guidance was used in 57 cases and fluoroscopy guidance in 22 cases. LFSC rupture was technically successful in 58 out of 79 cases (73 %). Mean injection volume for cyst rupture was 3.6 ± 2.2 mL and a combination of steroid and anesthetic was injected in all cases. Over a mean follow-up time of 44 months, 12 % of patients underwent repeat cyst rupture, and 46 % eventually underwent surgery, whereas the majority of patients (55 %) experienced symptomatic relief and did not undergo surgery. There was no significant association between a successful outcome and age, sex, level, or size of LFSC (p > 0.1). LFSCs with T2 hypointensity were more likely to require surgery (p = 0.02). There was one complication, a bacterial skin infection that completely resolved following antibiotic therapy. Percutaneous LFSC rupture is an effective and safe nonsurgical treatment option for LFSC. More than half of treated patients were able to avoid subsequent surgery. Therefore, percutaneous LFSC rupture should be considered before surgical intervention. (orig.)

  1. Application of a New Guiding System in Percutaneous Biopsies

    International Nuclear Information System (INIS)

    Petsas, Theodore; Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-01-01

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs

  2. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    Energy Technology Data Exchange (ETDEWEB)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua [University Hospital, University of Cologne, Department of Radiology, Cologne (Germany); Pfister, Roman [University Hospital, University of Cologne, Department of Internal Medicine III, Cologne (Germany); Deppe, Antje-Christin [University Hospital, University of Cologne, Department of Cardiothoracic Surgery, Cologne (Germany); Matoussevitch, Vladimir [University Hospital, University of Cologne, Department of Vascular Surgery, Cologne (Germany)

    2014-06-15

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  3. Thoracic type Ia endoleak: direct percutaneous coil embolization of the aortic arch at the blood entry site after TEVAR and double-chimney stent-grafts

    International Nuclear Information System (INIS)

    Bangard, Christopher; Franke, Mareike; Maintz, David; Chang, De-Hua; Pfister, Roman; Deppe, Antje-Christin; Matoussevitch, Vladimir

    2014-01-01

    To introduce a novel percutaneous technique to stop blood entry at the lesser aortic arch curvature by coil embolisation in type Ia endoleak after TEVAR. A 61-year-old Marfan patient presented with type Ia endoleak of the aortic arch and a growing aortic arch pseudoaneurysm after TEVAR. Multiple preceding operations and interventions made an endovascular approach unsuccessful. Direct percutaneous puncture of the aneurysmal sac would have cured the sign, but not the cause of blood entry at the lesser curvature of the aortic arch. Direct CT-guided percutaneous puncture of the blood entry site in the aortic arch with fluoroscopically guided coil embolisation using detachable extra-long coils was successfully performed. Three weeks after the intervention, the patient developed fever because of superinfection of the pseudoaneurysm. The blood cultures and CT-guided mediastinal aspirate were sterile. After intravenous administration of antibiotics, the fever disappeared and the patient recovered. Six-month follow-up showed permanent closure of the endoleak and a shrinking aneurysmal sac. Direct percutaneous puncture of the aortic arch at the blood entry site of a thoracic type Ia endoleak after TEVAR and double-chimney stent-grafts with coil embolisation of the wedge-shaped space between the lesser aortic curvature and the stent-graft is possible. (orig.)

  4. Image-guided drainage of multiple intraabdominal abscesses in children with perforated appendicitis: an alternative to laparotomy

    Energy Technology Data Exchange (ETDEWEB)

    McCann, Jeffrey W.; Krishnamurthy, Ganesh; Connolly, Bairbre L. [Hospital for Sick Children, Image Guided Therapy, Department of Diagnostic Imaging, Toronto, Ontario (Canada); Maroo, Sanjay; Amaral, Joao G.; Parra, Dimitri; Temple, Michael; John, Philip [Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Wales, Paul [Hospital for Sick Children, Department of Surgery, Toronto (Canada)

    2008-06-15

    Appendicitis is the most common cause of an acute abdomen in children. With perforation, multiple intraperitoneal collections can be seen at presentation. In this situation, surgical treatment alone is rarely effective. To determine the role of image-guided drainage in treating patients with acute appendicitis complicated by multiple intraabdominal collections. A retrospective review of patient charts and interventional radiology records was performed to identify all patients with acute complicated appendicitis treated by multiple image-guided drainage procedures. Data reviewed included the number of drainages and aspirations performed, drain dwell time, the clinical course and temperature profile, and the length of inpatient hospital stay and any complications experienced. The study population comprised 42 children with a mean age of 107.6 months. A total of 100 drainage catheters were inserted and 56 aspirations were performed. Of the 42 children, 24 were successfully treated at a single sitting, while 18 returned for further intervention. The mean drain dwell time was 8.18 days. The mean inpatient stay was 15.02 days. Treatment of the acute presentation with image-guided intervention was successful in 92.3% of children. Successful management of acute perforated appendicitis with multiple intraabdominal abscesses can be achieved with multiple minimally invasive image-guided drainage procedures. (orig.)

  5. Image-Guided percutaneous biopsies with a biopsy gun

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kyung Hwan; Lim, Hyo Keun; Kim, Eun Ah; Yun, Ku Sub; Bae, Sang Hoo; Shin, Hyung Sik [Hallym University College of Medicine, Seoul (Korea, Republic of)

    1994-07-15

    We report the results of image-guided percutaneous biopsies with a biopsy gun and evaluate the clinical usefulness. One hundred and five biopsies under ultrasonographic or fluoroscopic guidance were performed. Various anatomic sites were targeted(liver; 50, chest; 22, kidney; 12, pancreas; 8, intraperitoeum; 7, retroperitoneum; ). Obtained tissue was diagnostic in 98 of the 105 biopsies(93%). In each instance, representative core tissue specimens were obtained. Evaluation of the core tissue by pathologist revealed consistent, uniform specimens that contained significant crush artifact in no case. Five biopsies yielded inadequate tissue which were too small for histopathologic interpretation or were composed of necrotic debris. Two biopsies yielded adequate tissues, but tissues were not of the target. The diagnoses were malignancy in 77 biopsies and benign disease in 21 biopsies. No complications other than mild, localized discomfort were encountered except a transient hemoptysis and pneumothorax which was observed in two patients. Cutting biopsy with a biopsy gun provided sufficient amount of target tissue for an accurate diagnosis of malignant and benign disease. It was a safe and useful procedure for percutaneous biopsy.

  6. MDCT-Guided Transthoracic Needle Aspiration Biopsy of the Lung Using the Transscapular Approach

    International Nuclear Information System (INIS)

    Rossi, Umberto G.; Seitun, Sara; Ferro, Carlo

    2011-01-01

    The purpose of this study is to report our preliminary experience using MDCT-guided percutaneous transthoracic needle aspiration biopsy using the transscapular approach in the upper posterolateral lung nodules, an area that it is difficult or hazardous to reach with the conventional approach. Five patients underwent CT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach. A coaxial needle technique was used in all patients. Biopsy was successful in all patients. No major complications were encountered. One patient developed a minimal pneumothorax next to the lesion immediately after biopsy, which resolved spontaneously. MDCT-guided percutaneous transthoracic needle aspiration biopsy of the lung via the transscapular approach is an effective and safe procedure that reduces the risk of pneumothorax in selected patients.

  7. US-guided percutaneous biopsies with a biopsy gun

    International Nuclear Information System (INIS)

    Ahn, In Oak; Kim, Hyung Jin; Kim, Jae Hyung; Lee, Goo; Jung, Sung Hoon

    1993-01-01

    Core tissue for histologic study is believed by many pathologist to be more diagnostic than material from needle aspiration. Recently introduced automatched biopsy gun simplifies core biopsies with increased quantity and quality of samples. Authors performed 38 percutaneous biopsies from 38 patients with 18G automated biopsy guns under US guide. Diagnostic target tissues were obtained in 33 biopsies(87%), inadequate tissues in 4(11%), and adequate but not of target tissue in 1(3%). There was no major complication requiring treatment, but pain needing analgesics and pain with nausea/vomiting were experienced in 2 and 1 biopsies respectively. Average number of needle passes was 1.5. We concluded that US guided gun biopsy was a easy and safe way to obtain tissue samples of good quantity and quality, especially useful in hospitals without constant availability of specialist in cytopathology

  8. CT and fluoroscopy guided celiac ganglion block

    International Nuclear Information System (INIS)

    Lim, Sun Kyung; Kwon, Dae Ik; Ahn, Hyup; Kim, Jong Il; Kim, Byung Young; Lee, Jong Gil

    1994-01-01

    To evaluate the effects and usefulness of fluoroscopy guided celiac ganglion block after marking of needle path with CT scan. Celiac ganglion block with 100% ethyl alcohol was performed in 50 cancer patients who were inoperable and had intractable abdominal pain. Duration and degree of pain relief after the procedure and its complication were analyzed. Early pain relief was observed in 98% and long term relief in 68% without serious complication. Fluoroscopy guided celiac ganglion block after marking of needle path with CT scan was a safe and valuable procedure in relieving intractable pain in terminal cancer patients and reduced the time in the CT room

  9. A study on CT-guided stereotactic technique for functional neurosurgery

    International Nuclear Information System (INIS)

    Uetsuhara, Koichi; Asakura, Tetsuhiko; Hirahara, Kazuho; Gondo, Masazumi; Oda, Hiroshige

    1987-01-01

    Recently, CT-guided stereotactic surgery has become of major interest, and some authors have discussed its potential in functional neurosurgery. The following is a comparative study of the CT-guided stereotactic technique and the conventional roentogenographic stereotactic technique. The Brown-Roberts-Wells apparatus was used for both types of procedures. 37 stereotactic procedures were performed on 35 patients under local anesthesia; 16 for stereotactic biopsy and 21 for stereotactic functional neurosurgery. Target points for stereotactic biopsy were determined by the CT-guided technique and target points for functional neurosurgery were determined by the conventional roentogenographic technique. The correlation with the position of target point determined by both techniques was investigated in the 21 functional neurosurgical procedures. On these occasions the authors used the reformatted horizontal and sagittal CT through the anterior and posterior commissure to determine the position of target point by the CT-guided technique. Results: It was found that the AC-PC line crossed with Reid's base line at angle of 11 ± 1 deg, and therefore it is important to obtain a CT images including AC-PC line at this angle. When applying the CT guided stereotactic procedure for functional surgery, it should be known that there could be a discrepancy within 2 mm from the conventional target determination. (author)

  10. CT changes after lumbar percutaneous automated nucleotomy

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, R. (Depts. of Radiology, Section of Neuroradiology and Neurosurgery, Ullevaal Univ. Hospital, Oslo (Norway)); Amundsen, T. (Depts. of Radiology, Section of Neuroradiology and Neurosurgery, Ullevaal Univ. Hospital, Oslo (Norway)); Nakstad, P.H. (Depts. of Radiology, Section of Neuroradiology and Neurosurgery, Ullevaal Univ. Hospital, Oslo (Norway)); Magnaes, B. (Depts. of Radiology, Section of Neuroradiology and Neurosurgery, Ullevaal Univ. Hospital, Oslo (Norway))

    1994-09-01

    In order to assess changes occurring in disk hernias and disk spaces following percutaneous nucleotomy a follow-up CT was carried out an average of 6 months after treatment of 69 disks in 60 patients. Forty-three of the disks were also reexamined at an average of 11 months after the first follow-up. Twenty-seven percent of the hernias were reduced in size at the first follow-up. Fourteen percent were reduced and 7% had increased between the first and second follow-ups. The medium-sized and large hernias were more frequently reduced compared to the smaller ones. Reduction of the disk space was found in 29% of the cases at first follow-up. An additional 24% were reduced between the first and second follow-ups. No association was demonstrated between change in size of the herniation or disk space and clinical outcome or amount of nucleous material removed at nucleotomy. (orig.).

  11. Comparison of Dexmedetomidine and Midazolam in Sedation for Percutaneous Drainage of Hepatic Hydatid Cysts.

    Science.gov (United States)

    Bavullu, Emine Nilgün; Aksoy, Esra; Abdullayev, Ruslan; Göğüş, Nermin; Dede, Doğan

    2013-12-01

    Hydatid cyst still continues to be a public health problem. The basic treatment for the disease is surgery, but ultrasound-guided percutaneous drainage has become an important treatment alternative. Agents preferred for sedation during drainage performed under local anaesthesia must also preserve respiration and hemodynamic stability while providing adequate sedation. We compared the sedative properties of midazolam, which has a short duration of action, and a selective α2 adrenergic receptor agonist, dexmedetomidine, and the intraoperative complications. After approval by the clinical trials ethics committee, 40 patients with similar demographic data were randomized into two groups. All patients received 10 mg metoclopramide and 45.5 mg pheniramine before the procedure. Then, midazolam (0.07 mg kg(-1) IV bolus followed by 0.01 mg kg(-1) h(-1) infusion) was administered to Group 1, and dexmedetomidine (1 μg kg(-1) loading dose in 10 minutes, followed by 0.2 μg kg(-1) h(-1) continuous infusion) was administered to Group 2 for sedation. Just before the surgical procedure, all patients received IV propofol in a subhypnotic dose of 0.5 mg kg(-1); the dose was repeated if adequate sedation could not be achieved. Observer's assessment of alertness/sedation (OAA/S) scale and Bispectral index (BIS) were used to evaluate the sedation level during the procedure. Heart rate (HR), mean arterial pressure (MAP), respiratory rate (RR), peripheral oxygen saturation (SpO2) and end-tidal carbon dioxide pressure (ETCO2) were monitored before and after induction and every 5 minutes thereafter. Propofol requirement was noted for each group. Sedation in the dexmedetomidine group was as effective and adequate as that observed in the midazolam group. BIS values were significantly lower in the dexmedetomidine group, especially after 10 minutes and thereafter. RR, SpO2, and ETCO2 were similar in both groups, whereas clinically insignificant decreases in HR and MAP were observed in the

  12. Single-centre review of radiologically guided percutaneous nephrostomy using 'mixed' technique: Success and complication rates

    Energy Technology Data Exchange (ETDEWEB)

    Montvilas, Paulius, E-mail: paulmont@rm.dk [Department of Radiology, Aarhus University Hospital, Skejby, Brendstrupgardsvej 100, 8200 Aarhus N (Denmark); Solvig, Jan, E-mail: jansolvi@rm.dk [Department of Radiology, Aarhus University Hospital, Skejby, Brendstrupgardsvej 100, 8200 Aarhus N (Denmark); Bjerklund Johansen, Truls Erik, E-mail: tebj@skejby.rm.dk [Department of Urology, Aarhus University Hospital, Skejby, Brendstrupgardsvej 100, 8200 Aarhus N (Denmark)

    2011-11-15

    Aim: A review of complication and success rates of the 'mixed' technique in percutaneous nephrostomy using both the Seldinger and one-step techniques in dilated and non-dilated systems. Materials and methods: We retrospectively analysed 500 percutaneous nephrostomies in dilated an non-dilated systems in 353 patients from 2006 to 2007 (208 males (range 19-95 years), 127 females (range 27-91 years) and 21 children (range 3 months-16 years: 6 females, 15 males)). Percutaneous nephrostomy was considered successful if catheter was placed in renal pelvis and drained urine spontaneously. Successful percutaneous nephrostomies were classified as primary (renal system drained instantly) or postponed (drainage achieved within 24 h after initial failure). Number of complications was registered. Results: All of the 500 nephrostomies were successful within 24 h (96.2% primary; 3.8% postponed). The success rate of primary nephrostomy in dilated and non-dilated systems was 98.2% and 82%, respectively. Major complications occurred in 0.45% and minor complications in 14.2%. Conclusion: Percutaneous nephrostomy using the 'mixed' technique is very successful in dilated systems, is not superior to other PCN techniques in non-dilated systems and has a very low rate of major complications.

  13. Bowel lesions: percutaneous US-guided 18-gauge needle biopsy--preliminary experience.

    Science.gov (United States)

    Tudor, G R; Rodgers, P M; West, K P

    1999-08-01

    Ultrasonography-guided percutaneous biopsy was performed with local anesthesia and an 18-gauge needle in 10 patients with bowel-wall lesions. All patients underwent clinical review within 1 month. Biopsy was diagnostic in all patients. There were no complications, and all patients tolerated the procedure well. The technique appears to be safe and had an excellent diagnostic yield in our series.

  14. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children

    Energy Technology Data Exchange (ETDEWEB)

    Shellikeri, Sphoorti; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Zhu, Xiaowei; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Setser, Randolph M. [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States); Hwang, Tiffany J. [University of Southern California, Keck School of Medicine, Los Angeles, CA (United States); Girard, Erin [Siemens Medical Solutions USA, Inc., Princeton, NJ (United States)

    2017-07-15

    Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0

  15. Piezoelectrically Actuated Robotic System for MRI-Guided Prostate Percutaneous Therapy

    OpenAIRE

    Su, Hao; Shang, Weijian; Cole, Gregory; Li, Gang; Harrington, Kevin; Camilo, Alexander; Tokuda, Junichi; Tempany, Clare M.; Hata, Nobuhiko; Fischer, Gregory S.

    2014-01-01

    This paper presents a fully-actuated robotic system for percutaneous prostate therapy under continuously acquired live magnetic resonance imaging (MRI) guidance. The system is composed of modular hardware and software to support the surgical workflow of intra-operative MRI-guided surgical procedures. We present the development of a 6-degree-of-freedom (DOF) needle placement robot for transperineal prostate interventions. The robot consists of a 3-DOF needle driver module and a 3-DOF Cartesian...

  16. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  17. Mammary tuberculosis: percutaneous treatment of a mammary tuberculous abscess

    Energy Technology Data Exchange (ETDEWEB)

    Romero, C.; Carreira, C.; Cereceda, C.; Pinto, J. [Servicio de Radiologia, Hospital Virgen de la Salud, Toledo (Spain); Lopez, R.; Bolanos, F. [Servicio de Cirugia, Hospital Virgen de la Salud, Toledo (Spain)

    2000-03-01

    It is currently very rare to find mammary involvement in cases of tuberculosis, in either primary or secondary form. Diagnosis is classically clinical and microbiological, and the basic techniques used in imaging diagnosis are mammography and ultrasound. Computed tomography may define the involvement of the thoracic wall in those cases which present as mammary masses adhering to deep levels, and is also able to evaluate accompanying pulmonary disease, if it is present. Traditionally, treatment has consisted of quadrantectomy and specific antibiotic therapy. We present a case of tuberculous mammary abscess secondary to pulmonary disease, which was treated by percutaneous drainage controlled by CT and specific antibiotic therapy. We revise the diagnosis, differential diagnosis and treatment of mammary tuberculosis. (orig.)

  18. Mammary tuberculosis: percutaneous treatment of a mammary tuberculous abscess

    International Nuclear Information System (INIS)

    Romero, C.; Carreira, C.; Cereceda, C.; Pinto, J.; Lopez, R.; Bolanos, F.

    2000-01-01

    It is currently very rare to find mammary involvement in cases of tuberculosis, in either primary or secondary form. Diagnosis is classically clinical and microbiological, and the basic techniques used in imaging diagnosis are mammography and ultrasound. Computed tomography may define the involvement of the thoracic wall in those cases which present as mammary masses adhering to deep levels, and is also able to evaluate accompanying pulmonary disease, if it is present. Traditionally, treatment has consisted of quadrantectomy and specific antibiotic therapy. We present a case of tuberculous mammary abscess secondary to pulmonary disease, which was treated by percutaneous drainage controlled by CT and specific antibiotic therapy. We revise the diagnosis, differential diagnosis and treatment of mammary tuberculosis. (orig.)

  19. CT-guided percutaneous lung biopsy: Comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grand, David Justin, E-mail: dgrand@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Atalay, Michael A., E-mail: matalay@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Cronan, John J., E-mail: cronan@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Mayo-Smith, William W., E-mail: wmayo-smith@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States)

    2011-08-15

    Purpose: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm. Materials/methods: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below. Results: Average fluoroscopy time using CTF was 28.2 s compared to 35.0 s for EMN (p = 0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p = 0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p = 0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p = 0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p = 0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p = 0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p = 0.4). Conclusions: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.

  20. Impact of CT in patients with sepsis of unknown origin

    International Nuclear Information System (INIS)

    Barkhausen, J.; Stoeblen, F.; Mueller, R.D.

    1999-01-01

    Purpose: To evaluate the diagnostic relevance of CT in patients with sepsis of unknown origin. Material and Methods: Sixty-three consecutive intensive care patients with suspicion of an abscess and negative or inconclusive previous radiological examinations were included. CT was performed using the helical technique. A total of 45 abdominal and 38 chest examinations were evaluated. Results: 5/38 examinations of the chest revealed the source of sepsis (pleural empyema 2, lung abscess 1, mediastinitis 1, retrosternal abscess 1). 7/45 abdominal CT examinations showed the source of sepsis (intraabdominal abscess 2, hepatic abscess 3, intestinal perforation 1, gangrenous colitis 1). Conclusion: CT is useful for the evaluation of patients with fever or sepsis without a known source. Due to the detection of a spetic focus by CT, 19% of the patients in our study could be immediately referred to causal therapy as percutaneous drainage or surgery. (orig.)

  1. Impact of CT in patients with sepsis of unknown origin

    Energy Technology Data Exchange (ETDEWEB)

    Barkhausen, J.; Stoeblen, F.; Mueller, R.D. [University Hospital Essen (Germany). Dept. of Radiology; Dominguez-Fernandez, E. [University Hospital Essen (Germany). Dept. of General Surgery; Henseke, P. [Nycomed-Amersham Arzneimittel GmbH, Muenchen (Germany)

    1999-09-01

    Purpose: To evaluate the diagnostic relevance of CT in patients with sepsis of unknown origin. Material and Methods: Sixty-three consecutive intensive care patients with suspicion of an abscess and negative or inconclusive previous radiological examinations were included. CT was performed using the helical technique. A total of 45 abdominal and 38 chest examinations were evaluated. Results: 5/38 examinations of the chest revealed the source of sepsis (pleural empyema 2, lung abscess 1, mediastinitis 1, retrosternal abscess 1). 7/45 abdominal CT examinations showed the source of sepsis (intraabdominal abscess 2, hepatic abscess 3, intestinal perforation 1, gangrenous colitis 1). Conclusion: CT is useful for the evaluation of patients with fever or sepsis without a known source. Due to the detection of a spetic focus by CT, 19% of the patients in our study could be immediately referred to causal therapy as percutaneous drainage or surgery. (orig.)

  2. Percutaneous diagnosis and treatment in disease conditions of the bile ducts and the gallbladder

    International Nuclear Information System (INIS)

    Hauenstein, K.H.; Wimmer, B.; Salm, R.; Farthmann, E.H.

    1991-01-01

    Percutaneous transhepatic access to the bile duct has opened up new possibilities not only for diagnosis by means of cholangiography and cholangioscopy with endoscopically guided biopsy by small-bore equipment, but also for the treatment of benign and malignant obstructive jaundice. In malignant disease recanalization of the obstruction is possible by means of laser, intracavitary irritation, internal bile drainage in Klatskin tumors, large-diameter endoprostheses (e.g., a Y-shaped prosthesis) or metal stents. In benign disease, balloon dilatation of inflammatory stenoses, stone extractions from the bile duct or gallbladder by means of Dormia baskets, ultrasound or pezo electric shockwave-contact lithotripsy and chemical litholysis are possible very often percutaneous access is a real alternative to surgical intervention. (orig.) [de

  3. Ultrasound-guided thoracenthesis: the V-point as a site for optimal drainage positioning.

    Science.gov (United States)

    Zanforlin, A; Gavelli, G; Oboldi, D; Galletti, S

    2013-01-01

    In the latest years the use of lung ultrasound is increasing in the evaluation of pleural effusions, because it makes follow-up easier and drainage more efficient by providing guidance on the most appropriate sampling site. However, no standardized approach for ultrasound-guided thoracenthesis is actually available. To evaluate our usual ultrasonographic landmark as a possible standard site to perform thoracenthesis by assessing its value in terms of safety and efficiency (success at first attempt, drainage as complete as possible). Hospitalized patients with non organized pleural effusion underwent thoracenthesis after ultrasound evaluation. The point showing on ultrasound the maximum thickness of the effusion ("V-point") was chosen for drainage. 45 ultrasound guided thoracenthesis were performed in 12 months. In 22 cases there were no complications; 16 cases of cough, 2 cases of mild dyspnea without desaturation, 4 cases of mild pain; 2 cases of complications requiring medical intervention occurred. No case of pneumothorax related to the procedure was detected. In all cases drainage was successful on the first attempt. The collected values of maximum thickness at V-point (min 3.4 cm - max 15.3 cm) and drained fluid volume (min 70 ml - max 2000 ml) showed a significative correlation (p measure of the maximum thickness at V-point provides high efficiency to ultrasound guided thoracentesis and allows to estimate the amount of fluid in the pleural cavity. It is also an easy parameter that makes the proposed method quick to learn and apply.  

  4. Percutaneous liver biopsy. Overview of different techniques; Perkutane Leberbiopsie. Uebersicht ueber verschiedene Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Kettenbach, J.; Blum, M.; El-RaBadi, K.; Langenberger, H.; Happel, B.; Berger, J.; Ba-Ssalamah, A. [Universitaetsklinik fuer Radiodiagnostik, Medizinische Universitaet Wien (Austria)

    2005-01-01

    To classify a liver tumor, image-guided percutaneous biopsy of a liver lesion is indicated. Using ultrasound (US) to guide a biopsy needle into a liver lesion has been proven useful and safe. If a lesion cannot be seen on US or the access to a lesion has been complicated by its position, CT-guided biopsy can be performed. If a lesion cannot be delineated on US or CT, MR-guided biopsy is recommended. Using hepatospecific contrast agents, the time span to delineate tumor tissue can be prolonged. To differentiate diffuse liver disease, transvenous biopsy under fluoroscopic control can be performed if a percutaneous biopsy is contraindicated. In recent years fine-needle aspiration biopsy has been increasingly replaced by coaxial 14-20 G core biopsy, which is a safe and efficient technique to classify liver lesions and has a low complication rate. (orig.) [German] Zur definitiven Klaerung der Dignitaet und Tumorklasse einer Leberlaesion ist eine bildgesteuerte perkutane Biopsie indiziert. Unter Verwendung der Sonographie ist das Verfahren treffsicher und einfach. Die computertomographiegezielte Biopsie ist wegen der ueberlagerungsfreien, reproduzierbaren Darstellung von Leberherden und ihren Nachbarstrukturen in vielen Faellen besser geeignet. Fuer Laesionen, die sich weder mit Ultraschall noch mit CT biopsieren lassen, bietet sich die Magnetresonanztomographie an. Durch den Einsatz leberspezifischer Kontrastmittel kann das Zeitfenster zur Durchfuehrung einer Biopsie verlaengert werden. Zur Abklaerung diffuser Lebererkrankungen wird bei kontraindizierter perkutaner Biopsie eine transvenoese Leberbiopsie unter Durchleuchtung empfohlen. Die in den 1980er Jahren propagierte Feinnadelaspirationsbiopsie wurde zunehmend durch Stanzbiopsien (Durchmesser 14-20 gg) in koaxialer Technik ersetzt, da diese eine zuverlaessige artdiagnostische Klassifikation bei niedriger Komplikationsrate ermoeglichen. (orig.)

  5. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Si Yoon; Kwon, Jong Won [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-11-15

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect.

  6. Imaging-guided percutaneous needle biopsy for infectious spondylitis: Factors affecting culture positivity

    International Nuclear Information System (INIS)

    Sung, Si Yoon; Kwon, Jong Won

    2015-01-01

    To evaluate the variable factors affecting the results of percutaneous needle biopsies for infectious spondylitis. In all, 249 patients who underwent both MRI and percutaneous needle biopsies due to a suspicion of infectious spondylitis were evaluated with respect to the following factors: the usage of antibiotics before the procedure, the location of the biopsy, the guiding equipment used, the experience level of the operators, and the number of biopsies performed. The positivity of culture in cases of treated with antibiotics (16.3%) before the biopsy was lower than in the untreated cases (30.5%) (p = 0.004). Biopsies performed at the abscess (43.5%) and with fluoroscopic guidance (27.8%) showed higher culture positivity as well. The experience level of the operators and the number of biopsies had no effect on culture positivity. The usage of antibiotics before the biopsy, the biopsy's location, and the guiding equipment used affect the culture positivity, while the experience levels of the operators and the number of biopsies do not have an effect

  7. Early versus delayed laparoscopic cholecystectomy after percutaneous transhepatic gallbladder drainage.

    Science.gov (United States)

    Han, In Woong; Jang, Jin-Young; Kang, Mee Joo; Lee, Kyoung Bun; Lee, Seung Eun; Kim, Sun-Whe

    2012-03-01

    Percutaneous transhepatic gallbladder drainage (PTGBD) is a procedure to resolve acute cholecystitis (AC). It may decrease the technical difficulty of laparoscopic cholecystectomy (LC) and thus may facilitate successful surgery when a patients' condition improves. However, the timing of LC after PTGBD remains controversial. From 2004 to 2010, cholecystectomy after PTGBD was performed in 67 patients with AC. Group I members underwent LC within 72 h of PTGBD (n = 21), whereas group II members underwent LC at more than 72 h after PTGBD (n = 46). The open conversion rate was similar in the two groups. The perioperative complication rate was higher in group I than in group II, but with marginal significance (19.0 vs. 4.3%; p = 0.07). Mean operative time was longer in group I than in group II (79.3 ± 25.3 vs. 53.7 ± 45.3 min; p = 0.02). However, overall hospital stay was shorter in group I than in group II, but with marginal significance (10.8 ± 4.5 vs. 14.7 ± 9.3 days; p = 0.08). Pros and cons were well balanced between the two groups. Decisions on the timing of cholecystectomy after PTGBD should be made based on considerations of patient condition, hospital facilities, and surgical experience.

  8. T-tube drainage of the common bile duct choleperitoneum: etiology and management.

    Science.gov (United States)

    Daldoul, S; Moussi, A; Zaouche, A

    2012-06-01

    External drainage of the common bile duct by placement of a T-tube is a common practice after choledochotomy. This practice may result in the specific complication of bile peritonitis due to leakage after removal of the T-tube. This complication has multiple causes: some are patient-related (corticotherapy, chemotherapy, ascites), and others are due to technical factors (inappropriate suturing of the drain to the ductal wall, minimal inflammatory reaction related to some drain materials). The clinical presentation is quite variable depending on the amount and rapidity of intra-peritoneal spread of of bile leakage. Abdominal ultrasound (US), with US-guided needle aspiration and occasionally Technetium(99) scintigraphy are useful for diagnosis. Traditional therapy consists of surgical intervention including peritoneal lavage and re-intubation of the choledochal fistulous tract to allow for a further period of external drainage. When leakage is walled off and well-tolerated, a more nuanced and less invasive conservative therapy may combine percutaneous drainage with endoscopic placement of a trans-ampullary biliary drainage. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  9. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  10. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  11. Clinical application of percutaneous cholecystostomy in the treatment of high-risk patients with acute cholecystitis

    International Nuclear Information System (INIS)

    Qoap Delin; ZZhou Bing; Chen Shiwei; Dong Jiangnan; Hua Yingxue; Chen Bo

    2009-01-01

    Objective: To discuss the therapeutic strategy and the clinical efficacy of percutaneous cholecystostomy in treating high-risk patients with acute cholecystitis. Methods: During the period of Jan. 2006-June 2008, percutaneous cholecystostomy was performed in 27 high-risk patients with acute cholecystitis, consisting of lithic cholecystitis (n = 21) and non-lithic cholecystitis (n = 6). Of 27 patients, percutaneous cholecystostomy via transhepatic approach was performed in 22 and via transperitoneal approach in 5. The 7 F drainage catheter was used. Cholecystography was conducted before the drainage catheter was extracted. Results: Percutaneous cholecystostomy was successfully accomplished in all 27 cases, with a technical success rate of 100%. Postoperative patency of gallbladder drainage was obtained in 25 patients, with the relieving or subsiding of abdominal pain and the restoring of temperature and leukocyte account to normal range within 72 hours. In one patient, as the abdominal pain relief was not obvious 72 hours after the procedure, cholecystography was employed and it revealed the obstruction of the drainage catheter. After reopening of the drainage catheter, the abdominal pain was relieved. In another case, cholecystography was carried out because the abdominal pain became worse after the procedure, and minor bile leak was demonstrated. After powerful anti-infective and symptomatic medication, the abdominal pain was alleviated. The drainage catheter was extracted in 25 patients 6-7 weeks after the treatment. Of these 25 patients, 12 accepted selective cholecystectomy, 7 received percutaneous cholecystolithotomy and 6 with non-lithic cholecystitis did not get any additional surgery. The remaining two patients were living with long-term retention of the indwelling drainage-catheter. Conclusion: Percutaneous cholecystostomy is a simple, safe and effective treatment for acute cholecystitis in high-risk patients. This technique is of great value in clinical

  12. Fractional Flow Reserve-guided Percutaneous Coronary Intervention: Standing the Test of Time

    Directory of Open Access Journals (Sweden)

    Frederik M. Zimmermann, MD

    2016-05-01

    Full Text Available Percutaneous coronary intervention (PCI improves symptoms and prognosis in ischemia-inducing, functionally significant, coronary lesions. Use of fractional flow reserve allows physicians to investigate the ischemia-inducing potential of a specific lesion and can be used to guide coronary revascularization, especially in multivessel coronary artery disease. Fractional flow reserve-guided PCI has been extensively investigated. Results show that deferral of stenting in non-significant lesions is safe, whereas deferral of stenting in functionally significant lesions worsens outcome. FFR-guided PCI improves outcome in multivessel disease over angiography-guided PCI. Until recently, there was little known about the long-term outcome of FFR-guided revascularization and its validity in acute coronary syndromes. This review aims to address the new evidence regarding long-term appropriateness of FFR-guided PCI, the need for hyperemia to evaluate functional severity, and the use of FFR in acute coronary syndromes.

  13. Percutaneous tracheostomy with the guide wire dilating forceps technique : presentation of 171 consecutive patients

    NARCIS (Netherlands)

    Fikkers, Bernard G; van Heerbeek, Niels; Krabbe, Paul F M; Marres, Henri A M; van den Hoogen, Frank J A

    BACKGROUND: Evaluation of percutaneous tracheostomy (PT) with the guide wire dilating forceps (GWDF) technique. METHODS: Prospective study of perioperative complications, retrospective analysis of early and late complications in an ICU in a teaching university hospital. RESULTS: The success rate of

  14. Percutaneous tracheostomy with the guide wire dilating forceps technique: presentation of 171 consecutive patients.

    NARCIS (Netherlands)

    Fikkers, B.G.; Heerbeek, N. van; Krabbe, P.F.M.; Marres, H.A.M.; Hoogen, F.J.A. van den

    2002-01-01

    BACKGROUND: Evaluation of percutaneous tracheostomy (PT) with the guide wire dilating forceps (GWDF) technique. METHODS: Prospective study of perioperative complications, retrospective analysis of early and late complications in an ICU in a teaching university hospital. RESULTS: The success rate of

  15. A novel lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections

    DEFF Research Database (Denmark)

    Walter, Daisy; Will, Uwe; Sanchez-Yague, Andres

    2015-01-01

    BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate the effi......BACKGROUND AND STUDY AIMS: A novel large-diameter, lumen-apposing, self-expanding metal stent with bilateral flanges was recently developed for endoscopic ultrasound (EUS)-guided transmural drainage of symptomatic pancreatic fluid collections (PFCs). The aim of this study was to evaluate...

  16. Ultrasound guided percutaneous treatment and follow-up of Baker's cyst in knee osteoarthritis

    International Nuclear Information System (INIS)

    Köroğlu, Mert; Çallıoğlu, Mehmet; Eriş, Hüseyin Naim; Kayan, Mustafa; Çetin, Meltem; Yener, Mahmut; Gürses, Cemil; Erol, Bekir; Türkbey, Barış; Parlak, Ayşe Eda; Akhan, Okan

    2012-01-01

    Objective: Purpose of this study is to assess sonographic changes and clinical response in different subgroups of Baker's cyst patients with knee osteoarthritis after a single session of ultrasound-guided percutaneous aspiration and corticosteroid injection. Materials and methods: Thirty-two knee osteoarthritis patients (46–85 years, mean 58.97 ± 9.88) with symptomatic Baker's cyst diagnosed at ultrasonography were included in the study. To determine the grade of the symptoms, Visual Analogue Scale was applied. The patients were grouped in two, as simple (n = 24) and complex (n = 8) Baker's cyst. Thirty-two ultrasound-guided cyst aspirations concomitant 1 ml betamethasone injection (24 simple, 8 complex subgroups) were performed. Patients were followed clinically as well as via ultrasonography for 6 months after procedures. Results: A significant decrease in volume of the Baker's cysts after percutaneous treatment was accompanied by a significant clinical improvement. Moreover, the volume reduction of Baker's cyst after the treatment was significantly correlated with the clinical improvement (Pearson correlation coefficient = 0.542, p = 0.001). All 6 Baker's cysts relapsed at ultrasonography were complex type. Furthermore, a comparison of patients with simple Baker's cysts and those with complex Baker's cysts demonstrated no significant change in Visual Analogue Scale scores between two groups (p = 0.061, Mann–Whitney U). No complications (minor or major) occurred secondary to percutaneous treatment. Conclusion: Baker's cysts can be grouped as simple and complex groups via ultrasonography prior to the treatment. Cyst aspiration with ultrasound-guided corticosteroid injection yields clinical improvement and cyst volume reduction in all subgroups of patients with Baker's cyst secondary to knee osteoarthritis.

  17. Sonographically guided percutaneous muscle biopsy in diagnosis of neuromuscular disease: a useful alternative to open surgical biopsy.

    Science.gov (United States)

    O'Sullivan, Paul J; Gorman, Grainne M; Hardiman, Orla M; Farrell, Michael J; Logan, P Mark

    2006-01-01

    The purpose of this study was to evaluate the feasibility of sonographically guided percutaneous muscle biopsy in the investigation of neuromuscular disorders. Sonographically guided percutaneous needle biopsy of skeletal muscle was performed with a 14-gauge core biopsy system in 40 patients over a 24-month period. Patients were referred from the Department of Neurology under investigation for neuromuscular disorders. Sonography was used to find suitable tissue and to avoid major vascular structures. A local anesthetic was applied below skin only. A 3- to 4-mm incision was made. Three 14-gauge samples were obtained from each patient. All samples were placed on saline-dampened gauze and sent for neuropathologic analysis. As a control, we retrospectively assessed results of the 40 most recent muscle samples acquired via open surgical biopsy. With the use of sonography, 32 (80%) of 40 patients had a histologic diagnosis made via percutaneous needle biopsy. This included 26 (93%) of 28 patients with acute muscular disease and 6 (50%) of 12 patients with chronic disease. In the surgical group (all acute disease), 38 (95%) of 40 patients had diagnostic tissue attained. Sonographically guided percutaneous 14-gauge core skeletal muscle biopsy is a useful procedure, facilitating diagnosis in acute muscular disease. It provides results comparable with those of open surgical biopsy in acute muscular disease. It may also be used in chronic muscular disease but repeated or open biopsy may be needed.

  18. Real-time MRI-guided percutaneous sclerotherapy of low-flow head and neck lymphatic malformations in the pediatric population - a stepwise approach

    Energy Technology Data Exchange (ETDEWEB)

    Partovi, Sasan; Vidal, Lorenna; Lu, Ziang; Nakamoto, Dean A.; Buethe, Ji; Clampitt, Mark; Coffey, Michael; Patel, Indravadan J. [University Hospitals Cleveland Medical Center, Case Western Reserve University, Department of Radiology, Section of Vascular and Interventional Radiology, Cleveland, OH (United States)

    2017-05-15

    Real-time MRI-guided percutaneous sclerotherapy is a novel and evolving treatment for congenital lymphatic malformations in the head and neck. We elaborate on the specific steps necessary to perform an MRI-guided percutaneous sclerotherapy of lymphatic malformations including pre-procedure patient work-up and preparation, stepwise intraprocedural interventional techniques and post-procedure management. Based on our institutional experience, MRI-guided sclerotherapy with a doxycycline-gadolinium-based mixture as a sclerosant for lymphatic malformations of the head and neck region in children is well tolerated and effective. (orig.)

  19. Congenital Splenic Cyst Treated with Percutaneous Sclerosis Using Alcohol

    International Nuclear Information System (INIS)

    Anon, Ramon; Guijarro, Jorge; Amoros, Cirilo; Gil, Joaquin; Bosca, Marta M.; Palmero, Julio; Benages, Adolfo

    2006-01-01

    We report a case of successful percutaneous treatment of a congenital splenic cyst using alcohol as the sclerosing agent. A 14-year-old female adolescent presented with a nonsymptomatic cystic mass located in the spleen that was believed to be congenital. After ultrasonography, a drainage catheter was placed in the cavity. About 250 ml of serous liquid was extracted and sent for microbiologic and pathologic studies to rule out an infectious or malignant origin. Immediately afterwards, complete drainage and local sclerotherapy with alcohol was performed. This therapy was repeated 8 days later, after having observed 60 ml of fluid in the drainage bag. One year after treatment the cyst has practically disappeared. We believe that treatment of splenic cyst with percutaneous puncture, ethanolization, and drainage is a valid option and it does not rule out surgery if the conservative treatment fails

  20. Painful percutaneous transthoracic needle biopsy of Schwannoma: a case report

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chun, Kyung Ah; Kim, Young Joo; Park, Seog Hee; Shin, Kyung Sub; Lee, Eun Jung

    1995-01-01

    Percutaneous aspiration needle biopsy of the intrathoracic disease is a safe, easy, and accurate diagnostic method. It usually causes mild pain or discomfort during the procedure. We had a patient who complained of severe sharp pain, well localized at the biopsy site of the target mass during CT-guided transthoracic aspiration biopsy. It was pathologically confirmed as an intrathoracic schwannoma after special staining. To our knowledge, there has been no published report of such a painful percutaneous needle biopsy in a patient with schwannoma in Korea. Two cases were reported in other radiologic journals. The severe sharp pain developed during the transthoracic aspiration needle biopsy is a reliable sign of neurogenic tumor, therefore the participating radiologist should recommend specific immumochemical stain for neurogenic tumor to pathologist