WorldWideScience

Sample records for ct virtuelle otoskopie

  1. Virtuelle kroppe

    DEFF Research Database (Denmark)

    Buhl, Mie

    2009-01-01

      Abstract: ‘Hvordan bebor kroppen verden i en globaliseret virtuel realitet?    Denne artikel omhandler, hvordan virtuelle kroppe opstår i forskellige kontekster på tværs af kunst og medier på tværs af fysiske og virtuelle rum. Endvidere disktuterer jeg de metodologisk implikationer af at anvend...

  2. Skattemæssig behandling af virtuelle valutaer

    DEFF Research Database (Denmark)

    Kjærsgaard, Louise Fjord; Weber, Katja Dyppel

    2018-01-01

    Udbredelsen og anvendelsen af virtuelle valutaer er stigende, og der synes derfor behov for en analyse af den skattemæssige kvalifikation og behandling heraf. Skatterådet har ved to lejligheder haft mulighed for at foretage denne analyse; i henholdsvis SKM2014.226.SR om Bitcoins og SKM2017.520.SR...

  3. Kognitiv empowerment gennem virtuelle fællesskaber

    DEFF Research Database (Denmark)

    Schmidt, Dorte; Konnerup, Ulla

    2009-01-01

    samfundet. Med afsæt i den nyeste hjerneforskning diskuteres, hvordan kognitiv fitness i virtuelle fællesskaber kan føre til kognitiv empowerment, således at hjerneskadede mennesker fortsat kan fungere som selvstændige og myndige personer, der er i stand til selv at modvirke afmagt og afhængighed samt...

  4. Virtuelle Forschungsumgebungen in der Geschichtswissenschaft – Lösungsansätze und Perspektiven

    Directory of Open Access Journals (Sweden)

    Thomas Meyer

    2011-03-01

    Full Text Available Seit 2008 werden „Virtuelle Forschungsumgebungen“ durch die Deutsche Forschungsgemeinschaft (DFG in einem Programm im Bereich der Literatur-und Informationsversorgung gefördert, vorangegangen sind dem verschiedene Entwicklungen vor allem in Großbritannien, wo das Thema schon einige Jahre früher auf der Agenda stand. „Virtuelle Forschungsumgebungen“ werden unter anderem entwickelt für die Schulbuchforschung (edumeres.net , die Asienstudien (crossasia , für eine „Visuelle Ethnologie“ , im Bereich der Kunstgeschichte (Meta-Image oder die neutestamentliche Textforschung. Am Institut für Geschichtswissenschaften der Humboldt-Universität zu Berlin beschäftigen sich die dort angesiedelten Projekte H-Soz-u-Kult und dessen Trägerverein Clio-online - Historisches Fachinformationssystem e.V. seit Beginn 2009 mit dem Thema; nach einem positiven Bescheid der DFG über die finanzielle Förderung zur Überführung der im Rahmen von Clio-online, H-Soz-u-Kult und damit verbundenen Projekten entwickelten Fachinformations- und Kommunikationsdienste in eine „Virtuelle Forschungsumgebung“ steht seit Januar 2011 deren praktische Umsetzung auf der Agenda des auf zwei Jahre angelegten Infrastrukturprojekts.

  5. Virtuelle Okklusion – Kieferorthopädische und Biomechanische Anwendungen

    DEFF Research Database (Denmark)

    Dalstra, Michel

    Edward Angle lag richtig mit seiner Feststellung, dass die ersten Molaren als Schlüssel der Okklusion angesehen werden können. Die virtuelle Okklusion ist innerhalb der Kieferorthopädie und darüber hinaus ein vielseitiges Werkzeug, um die Okklusionskontakte zu quantifizieren und digital zu...

  6. Rum, rammer og biblioteker i den virtuelle verden

    DEFF Research Database (Denmark)

    Heilesen, Simon

    2009-01-01

    Med udgangspunkt i en kort introduktion til hvordan rum og rammer gestaltes i den virtuelle 3‐D verden Second Life, undersøger denne artikel, på hvilke måder rum og rammesætning anvendes og opleves i en faglig sammenhæng. Som eksempel anvendes det danske biblioteksprojekt i Second Life, Info Island...

  7. Virtuelle Auskunft mit Mehrwert : Chatbots in Bibliotheken

    OpenAIRE

    Christensen, Anne

    2008-01-01

    Die virtuelle Auskunft mit Hilfe elektronischer Informationsassistenten, auch Chatbots oder Chatterbots genannt, ist ein seit dem Jahr 2004 zu beobachtender Trend im deutschen Bibliothekswesen. Die Arbeit stellt die vier Chatbots ASKademicus, Stella, INA und das Sachsen-I vor. Am Beispiel von Stella aus der SUB Hamburg werden dann die Funktionsweise von Chatbots sowie die Anforderungen an die Konzeption dieser virtuellen Berater erläutert. Den Schwerpunkt der Arbeit bilden der Vergleich von C...

  8. Spontane strategier i innovationsnetværk: materialitetens betydning for stabiliseringen af virtuelle verdner som professionelt kommunikationsmedie [Spontaneous strategies in innovation networks: The importance of materiality in stabilising virtual worlds

    Directory of Open Access Journals (Sweden)

    Emil Husted

    2012-09-01

    Full Text Available Megen forskning har beskæftiget sig med, hvordan sociale og organisatoriske processer ændres, når de finder sted i virtuelle rum. Denne artikel tager udgangspunkt i innovationsprocesser, hvor aktører forsøger at etablere virtuelle verdner som platform for professionel kommunikation, men i stedet for at fokusere på kommunikationsprocesser internt i virtuelle verdner vil artiklen stille spørgsmålstegn ved dikotomien mellem den fysiske og den virtuelle verden og undersøge materialitetens betydning for organiseringen af det virtuelle. Ved at anlægge et perspektiv inspireret af Aktør Netværks Teori vil artiklen argumentere for, at fysiske steder og objekter ikke blot fungerer som kontekst for innovationsprocesser, men tværtimod inddrages som strategiske ressourcer, der aktivt medskaber de virtuelle verdner. Empirisk funderes analysen i fem danske virksomheder og viser, hvordan virksomhederne benytter sig af fysiske steder og objekter som strategisk ressource i innovationsprocessen. Hermed bidrager artiklen til litteraturen omkring innovation inden for nye medier såsom virtuelle verdner.

  9. Die Virtuelle Universität. Idee, Konzepte, Erfahrungen

    Directory of Open Access Journals (Sweden)

    Horst Dichanz

    2017-06-01

    Full Text Available Der Autor stellt in seinem Beitrag das Projekt der Virtuellen Universität (VU vor. Diese Virtuelle Universität zeichnet sich durch ein System aus, in dem alle Funktionen einer Universität vollständig virtuell integriert sind. Im Anschluss an Erfahrungen aus der Praxis der VU werden bildungspolitische Perspektiven der FernUniversität diskutiert. Auch neue Medien im erziehungswissenschaftlichen Studium an einer Präsenzuniversität sind noch nicht selbstverständlich. Dabei gibt es eine Reihe von Vorteilen und Möglichkeiten des Online-Lehrens und -Lernens. (DIPF/Orig..

  10. Genèse d’une communauté virtuelle d’apprenants dans le cadre d’une démarche d’apprentissage collaboratif à distance

    Directory of Open Access Journals (Sweden)

    Sylvie Grosjean

    2008-03-01

    Full Text Available L’objectif de cet article est de présenter une analyse du processus d’émergence d’une communauté virtuelle d’apprenants dans le cadre d’une démarche d’apprentissage collaboratif à distance. Par conséquent, nous proposons une analyse empirique de la phase initiale de développement d’une communauté virtuelle d’apprenants, que nous nommons la phase d’engagement, afin de mieux la décrire et la comprendre. Pour ce faire, nous procédons à une analyse des interactions communicatives entre étudiants en s'appuyant sur l’étude de formes langagières et instrumentées de communication s'accomplissant lors d’échanges asynchrones (via un forum de discussion. The aim of this article is to analyse the emergence of the learner’s virtual community by analysing the interactions between subjects communicating via a discussion forum. We propose an empirical analysis of the initial phase of development that we name the engagement phase in the collaborative online learning setting . We will present an empirical analysis of an interactive dynamic through the analysis of linguistic (electronic conversation and non linguistic (artefacts, intermediary objects forms of communication.

  11. Virtuelle Realität zur Bereitstellung integrierter Suchumgebungen

    Directory of Open Access Journals (Sweden)

    Thies Pfeiffer

    2017-12-01

    Full Text Available Das Exzellenzcluster Kognitive Interaktionstechnologie (CITEC an der Universität Bielefeld beschäftigt sich seit 2013 mit der virtuellen Realität (VR. Ausgehend von konkreten Projektkooperationen (Publikations- und Forschungsdatenmanagement mit der Universitätsbibliothek ist die Idee entstanden, mit der in 2016 neu angebotenen Konsumer-VR-Hardware die im Labor entwickelten Interaktionstechniken auf geeignete Szenarien im Bereich von bibliothekarischen Umgebungen anzuwenden. Als interessantes Anwendungsgebiet kristallisierte sich im gemeinsamen Diskurs die Literatursuche heraus: Als Suchsystem wurde die Bielefelder BASE-Datenbank (d.i. Bielefeld Academic Search Engine mit inzwischen mehr als 100 Mio. indexierten Dokumenten ausgewählt. Diese Auswahl erfolgte vor dem Hintergrund, dass sich die von zahlreichen externen Institutionen bereits genutzte API-Schnittstelle als universell und robust erwiesen hat und umfangreiche Funktionen bereitstellt. Auf der Grundlage der umfangreichen theoretischen und praktischen Erfahrungen des CITEC mit VRTechniken wurde der Prototyp für eine virtuelle Suchumgebung realisiert, der ein Retrieval in einem Suchraum von Online-Dokumenten erlaubt. Die Nutzerinnen und Nutzer können die Suchanfrage explorativ zusammenstellen und dabei die Ergebnisse intuitiv verwalten. Unterstützt werden sie dabei durch Ergebnisanzeige, Sortierung, Optimierung des Suchergebnisses mittels Suchverfeinerung (Drilldown-basiert oder Anfrageerweiterung und Wiederverwendung von abgelegten Ergebnissen. Gleichzeitig wird der Zugriff- und Lizenzstatus visualisiert und die Detailanzeige der Metadaten des Objektes integriert. CITEC (Cluster of Excellence Cognitive Interaction Technology at Bielefeld University has been engaged in virtual reality (VR since 2013. Based on concrete joint project activities (publication and research data management together with Bielefeld University Library the idea emerged to use consumer-VR hardware to transfer

  12. Restauration virtuelle de l’art pariétal paléolithique : le cas de la grotte de Marsoulas

    Directory of Open Access Journals (Sweden)

    Carole Fritz

    2012-04-01

    Full Text Available Les techniques de scanner 3D sont appliquées dans des grottes et abris préhistoriques ornés avec un succès croissant. L’imagerie 3D peut même aider à restaurer les fresques des cavernes endommagées par le temps et les hommes. Pour la première fois, la « restauration virtuelle » d’une galerie ornée a été réalisée dans la grotte de Marsoulas ; cette opération n’a pu être accomplie qu’en combinant la technologie 3D aux résultats de l’étude scientifique du site et du relevé des parois ornées.The techniques of 3D scanning are being applied in prehistoric caves and rock-shelters with increasing success. 3D imaging can even help restore the paintings of caves damaged by weathering or by human interventions (graffiti. For the first time, the ‘virtual restoration’ of a decorated gallery was undertaken in the cave of Marsoulas. This operation required the combination of 3D technology with the results of the scientific study of the site and the decorated walls.

  13. Virkeligheder i Second Life

    DEFF Research Database (Denmark)

    Jensen, Sisse Siggaard

    "Virkeligheder i Second Life" er en beretning, der bygger på tre case studier samt omfattende observationer i den virtuelle verden Second Life i perioden 2006 til 2008. Beretningen er den ene af to bøger der bygger på forskning i virtuelle verdener; de tre case studier er: Wonderful Denmark, en...... virtuel virksomhed, Literary, et virtuelt bibliotek, Times, en afdeling af en real life virksomhed. Den anden bog: "Oplevelser i en virtuel verden" omhandler den virtuelle verden EverQuest - et masserollespil....

  14. Rezension: Contact • Conflict • Combat: Zur Tradition des Konfliktes in digitalen Spielen von Rudolf Thomas Inderst und Peter Just (Hg.

    Directory of Open Access Journals (Sweden)

    Karl H. Stingeder

    2014-12-01

    Full Text Available Virtuelle Spielräume sind heterogene Zonen der Widersprüchlichkeit: Als solche bilden sie Schnittpunkte für virtuelle Kontakte, Konflikte und Kämpfe. Die Tradition des Konflikts in digitalen Spielen ergibt ein Spiegelbild der Kultur – mit der Beleuchtung von Konflikten wird die Entwicklung der Menschheit reflektiert.

  15. Virtuelle Patienten: Wie werden sie aus Sicht von Medizinstudierenden am besten eingesetzt? [Virtual patients: Which kind of teaching method is most attractive to medical students?

    Directory of Open Access Journals (Sweden)

    Riemer, Martin

    2013-11-01

    Full Text Available [english] “Virtual Patients” (VPs enable medical students to simulate a patient encounter before their first real patient contact. Later they can also be used to assess and train students’ abilities to recognize and treat selected diseases. This is especially valuable as medical schools are normally linked to maximum medical care hospitals with increasing difficulties to present patients with less serious medical conditions to their students . Five different approaches were taken to find out which is the best way to use VPs in medical education. From the student’s points of view best results can be achieved in the majority of cases when students worked in groups of two up to about ten. [german] „Virtuelle Patienten“ (VP ermöglichen es Medizinstudierenden eine Begegnung mit Patienten zu simulieren, bevor sie ihren ersten realen Patientenkontakt haben. Später im Studium können VP genutzt werden, um ausgewählte Krankheiten zu erkennen oder deren Behandlung zu üben. Dies ist besonders wichtig, weil in Ausbildungskrankenhäusern der Maximalversorgung immer weniger Patienten mit normalen Erkrankungen als Beispiel für die Studierenden zu finden sind . Fünf verschiedene Ansätze wurden genutzt um herauszufinden, auf welche Art man VP am besten in der medizinischen Ausbildung einsetzen kann. Aus der Sicht der Studierenden können in der Mehrzahl der Fälle die besten Ergebnisse erzielt werden, wenn Studierende in Gruppen von zwei bis zu ungefähr zehn Personen unterrichtet werden.

  16. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  17. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  18. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  19. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  20. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  1. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  2. Engagerende didaktiske design i blendede læringsrum

    DEFF Research Database (Denmark)

    Konnerup, Ulla; Dau, Susanne

    2017-01-01

    virtuelle og fysiske miljøer motiverer til forskellige aktiviteter. Forskningsspørgsmålet som stilles er: Hvilke didaktiske design i de blendede læringsmiljøer motiverer studerendes engagement, og hvad betyder fællesskabet i fysiske og virtuelle miljøer for dette engagement? De to cases afslører, hvorledes...... didaktisk design nødvendigvis må facilitere etableringen af forpligtende fællesskaber, gennem de studerendes engagement....

  3. Texturierung und Visualisierung virtueller 3D-Stadtmodelle

    OpenAIRE

    Lorenz, Haik

    2011-01-01

    Im Mittelpunkt dieser Arbeit stehen virtuelle 3D-Stadtmodelle, die Objekte, Phänomene und Prozesse in urbanen Räumen in digitaler Form repräsentieren. Sie haben sich zu einem Kernthema von Geoinformationssystemen entwickelt und bilden einen zentralen Bestandteil geovirtueller 3D-Welten. Virtuelle 3D-Stadtmodelle finden nicht nur Verwendung als Mittel für Experten in Bereichen wie Stadtplanung, Funknetzplanung, oder Lärmanalyse, sondern auch für allgemeine Nutzer, die realitätsnah dargestellte...

  4. Virtual neutron scattering experiments - Training and preparing students for large-scale facility experiments

    Directory of Open Access Journals (Sweden)

    Julie Hougaard Overgaard

    2016-11-01

    Full Text Available Dansk Vi beskriver, hvordan virtuelle eksperimenter kan udnyttes i et læringsdesign ved at forberede de studerende til hands-on-eksperimenter ved storskalafaciliteter. Vi illustrerer designet ved at vise, hvordan virtuelle eksperimenter bruges på Niels Bohr Institutets kandidatkursus om neutronspredning. I den sidste uge af kurset, rejser studerende til et storskala neutronspredningsfacilitet for at udføre neutronspredningseksperimenter. Vi bruger studerendes udsagn om deres oplevelser til at argumentere for, at arbejdet med virtuelle experimenter forbereder de studerende til at engagere sig mere frugtbart med eksperimenter ved at lade dem fokusere på fysikken og relevante data i stedet for instrumenternes funktion. Vi hævder, at det er, fordi de kan overføre deres erfaringer med virtuelle eksperimenter til rigtige eksperimenter. Vi finder dog, at læring stadig er situeret i den forstand, at kun kendskab til bestemte eksperimenter overføres. Vi afslutter med at diskutere de muligheder, som virtuelle eksperimenter giver. English We describe how virtual experiments can be utilized in a learning design that prepares students for hands-on experiments at large-scale facilities. We illustrate the design by showing how virtual experiments are used at the Niels Bohr Institute in a master level course on neutron scattering. In the last week of the course, students travel to a large-scale neutron scattering facility to perform real neutron scattering experiments. Through student interviews and survey answers, we argue, that the virtual training prepares the students to engage more fruitfully with experiments by letting them focus on physics and data rather than the overwhelming instrumentation. We argue that this is because they can transfer their virtual experimental experience to the real-life situation. However, we also find that learning is still situated in the sense that only knowledge of particular experiments is transferred. We proceed to

  5. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  6. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  7. Virtuelle sicherheiten

    CERN Multimedia

    Schmitz, Heinz

    2007-01-01

    In the past week, 11'000 computer specialists met at the "vmWorld" in San Francisco, in order to talk about virtualisation of computers. The main point was the changed requirements at computing centres and server landscapes. (1,5 page)

  8. Virtuelle ting

    DEFF Research Database (Denmark)

    Mathiasen, Peter Dueholm

    2014-01-01

    In the article it is discussed whether virtual items can be described as "rørlige ting” (movable objects) and therefore subject to protection against e.g. theft under the Danish Criminal Code. Norwegian, Swedish and Dutch criminal laws are included in the article.......In the article it is discussed whether virtual items can be described as "rørlige ting” (movable objects) and therefore subject to protection against e.g. theft under the Danish Criminal Code. Norwegian, Swedish and Dutch criminal laws are included in the article....

  9. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  10. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  11. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  12. Virtual power plants in energy industry law. Possible manifestations and from them resulting legal questions; Virtuelle Kraftwerke im Energiewirtschaftsrecht. Moegliche Erscheinungsformen und daraus resultierende Rechtsfragen

    Energy Technology Data Exchange (ETDEWEB)

    Kahlbrandt, Lea Katharina [Bucerius Law School, Hamburg (Germany)

    2017-08-15

    Although cogeneration plants are operated with fossil fuels are not quite as environmentally friendly as EEG systems they have a much more favorable effect due to their high efficiency climate as conventional power plants. In the future this could can even improve with the aid of fuel cell technology. Therefore, they play for the transition to a safe and secure more efficient power supply conditions for a merger of cogeneration plants overall favorable, in particular because that no influence on the or the emission trading obligation of the plant operators has. However, the complete elimination of avoided network charges could be counterproductive. Just virtual power plants of cogeneration plants have an effect on a feed-in that the grid not charged, so fees for a decentralized feed in these cases can be justified. Also the development of cogeneration development within the framework of the newly introduced calls will have a major impact on the development of virtual power stations. [German] Zwar sind KWK-Anlagen, die mit fossilen Brennstoffen betrieben werden, nicht ganz so umweltfreundlich wie EEG-Anlagen, doch haben sie aufgrund ihres hohen Wirkungsgrades eine viel guenstigere Klimabilanz als konventionelle Kraftwerke. In Zukunft koennte diese sich mithilfe der Brennstoffzellen-Technologie sogar noch verbessern. Daher spielen sie fuer den Uebergang zu einer sicheren und klimafreundlicheren Stromversorgung eine wichtige Rolle. Die Bedingungen fuer einen Zusammenschluss von KWK-Anlagen sind insgesamt guenstig, insbesondere weil jener keinen Einfluss auf die Foerdersaetze oder die Emissionshandelspflicht der Anlagenbetreiber hat. Allerdings koennte die vollstaendige Abschaffung vermiedener Netzentgelte kontraproduktiv sein. Gerade virtuelle Kraftwerke aus KWK-Anlagen wirken auf eine Einspeisung hin, die das Netz nicht ueberfordert, sodass Entgelte fuer eine dezentrale Einspeisung in diesen Faellen durchaus eine Rechtfertigung haben. Auch die Entwicklung des KWK

  13. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  14. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  15. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  16. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  17. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  18. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  19. Virtual Reality: State of Military Research and Applications in Member Countries (La realite virutelle: L’etat actuel des travaux de recherche et des applications militaires dans les pays membres de l’Alliance)

    Science.gov (United States)

    2003-02-01

    avec des réglages ergonomiques) avec un casque de Réalité Virtuelle (Kaiser Proview 60) en 1999. Cette équipe est également le chef de file du projet...7B.7.2 Activité Image - ENSAM L’activité Image propose un mastère spécialisé en simulation et Réalité Virtuelle. Le but est de former des chefs de...Large-Scale Virtual Worlds. Conference Companion ACM SIGCHI 󈨣, 45-46. Darken, R.P. (1994). Hands-Off Interaction With Menus in Virtual Spaces

  20. Nyt fokus på informationsbegrebet i virtuel problemorienteret projektpædagogik

    DEFF Research Database (Denmark)

    Riis, Marianne

    2007-01-01

    Artiklen beskriver Masteruddannelsen i Ikt og Læring (MIL)'s erfaringer med deltagelse i pilotprojektet "Den virtuelle Bibliotekar" i samarbejde med Aalborg Universitetsbibliotek (AUB) i perioden efteråret 2005 til og med foråret 2006. Begreberne information, informationskompetence og ikke mindst...... læring diskuteres retrospektivt, således som disse ved projektets start var indlejret i MIL organisationen og dermed uddannelsen. Rammerne for "Den Virtuelle Bibliotekar" skitseres og de konkrete erfaringer, der udsprang af projektet opsummeres. Samtidig advokerer artiklen for et nyt fokus på information...

  1. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  2. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  3. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  4. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  5. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  6. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  7. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  8. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  9. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  10. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  11. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  12. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  13. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  14. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  15. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  16. Det ligger i luften

    DEFF Research Database (Denmark)

    Klitmøller, Anders; Lauring, Jakob; Jonsen, Karsten

    2011-01-01

    Multikulturelle virtuelle teams er en udbredt samarbejdsform i større danske virksomheder, specielt til løsning af videns intensive og kreative opgaver. Som leder kan man umiddelbart opnå fleksibilitet og besparelser ved brug af virtuelle teams, men desværre bliver disse fordele ofte spoleret af ......’ medier, såsom telefon og videokonference, ikke altid er effektive til kreative opgaver, da sproglig og kulturel friktion kan forøges ved brug af disse. De forskningsmæssige implikationer af studiet diskuteres, og ledelsestiltag, som imødegår disse udefordringer udfordringer, belyses....

  17. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  18. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  19. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  20. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  1. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  2. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  4. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  5. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  7. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  9. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  10. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  11. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  12. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  13. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  14. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  15. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  16. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  17. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  18. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  19. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  20. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  1. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  4. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  5. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  6. Projet TECHNE : vers un apprentissage collaboratif dans une classe virtuelle bilingue TECHNE Project: Towards collaborative learning in bilingual virtual classrooms

    Directory of Open Access Journals (Sweden)

    Roisin Donohoe

    2000-06-01

    Full Text Available La Communication Médiatisée par Ordinateur (CMO permet l’élargissement des frontières temporelles et spatiales de la salle de classe. Son exploitation pédagogique a donné naissance à de nombreux projets d’apprentissage des langues étrangères dont les fondements théoriques trouvent leurs origines dans les théories socioculturelles de l’apprentissage. La théorie de l’activité (TA, issue des travaux inspirés par Vygotsky, nous permet quant à elle de mieux appréhender le rôle de médiation que les outils et artefacts jouent dans un apprentissage collaboratif tout en fournissant un cadre de référence facilitant la description des processus en jeu au cours d’un tel apprentissage. TECHNE, projet de recherche-action conçu pour promouvoir un apprentissage collaboratif au sein de classes virtuelles et bilingues, s’inscrit dans une telle perspective. Après une description du projet, nous nous attachons à examiner certains des processus de collaboration en ligne que nous avons pu observer. Les résultats préliminaires d’une analyse quantitative des échanges effectués en ligne précèdent une étude qualitative d’échanges étalés sur plusieurs jours ou plusieurs heures. Nous formulons alors des axes de recherche future visant à mieux intégrer apprentissage de la langue et développement de compétences interculturelles et transversales.Computer Mediated Communication (CMC opens up the frontiers of the classroom. The use of CMC as a pedagogical tool has led to the creation of a number of language learning projects which call on the socio-cultural theories of learning. Activity Theory, originating from Vygotsky’s work, can help us to understand the mediation role of tools and artefacts in a collaborative learning environment while, at the same time supplying a framework for the description of the factors which come into play within such an environment. TECHNE, which was designed to promote collaborative learning

  7. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  8. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  9. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  13. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  14. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  15. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  16. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  17. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  18. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  19. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  4. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  5. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  6. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  7. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  8. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  9. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  10. CT pelvimetry

    International Nuclear Information System (INIS)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J.

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique [fr

  11. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  13. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  14. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  15. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  16. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  17. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  18. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  19. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  5. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  6. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  7. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  8. CT arteriography of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, K; Matsuura, K; Baba, H; Numaguchi, Y; Komaki, S [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-04-01

    The technique of CT arteriography was introduced, and CT images of the upper abdomen were explained. Very clear enhancement of parenchyma and vessels (especially portal vein) of the object organs could be obtained by CT arteriography of the upper abdomen, anatomical structures of organs were identified more easily by CT arteriography than by conventional CT, and the amount of information obtained was increased by using CT arteriography. However, the indication of CT arteriography must be limited, because of its complexity that CT arteriography is performed after angiography and involves the invasion of patients' bodies. As described in many reports, CT arteriography is useful for malignant tumors of the liver, and it is worthwhile, especially when surgery for hepatocellular carcinoma is considered. CT arteriography for organs except the liver has not been discussed sufficiently. Therefore, an application of this method for other organs must be decided after consideration of the balance of the amount of information obtained by CT arteriography with invasion to patients.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  10. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM)

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M.; Kersting, S.; Putz, R.; Mueller-Gerbl, M.

    2003-01-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p [de

  11. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  12. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  13. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  14. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  17. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  18. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  19. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  20. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  1. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  2. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  3. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    Science.gov (United States)

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  4. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  5. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  6. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  7. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  8. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  9. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  10. CT of thymoma

    International Nuclear Information System (INIS)

    Sone, Shusuke; Higashihara, Tokuro; Morimoto, Shizuo; Ikezoe, Junpei; Arisawa, Jun

    1982-01-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cases with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contoures with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images. (author)

  11. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  12. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  13. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  14. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  15. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  16. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  17. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  19. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  20. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Gietema, Hester A.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands); Isgum, Ivana; Mol, Christian P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Zanen, Pieter [University Medical Center Utrecht, Pulmonology, Utrecht (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Centre, Radiology, Nijmegen (Netherlands); University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands)

    2012-12-15

    To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3 months. Inspiratory and expiratory low-dose CT was obtained using breath hold instructions. CT air trapping was defined as the percentage of voxels in expiratory CT with an attenuation below -856 HU (EXP{sub -856}) and the expiratory to inspiratory ratio of mean lung density (E/I-ratio{sub MLD}). Variation was determined using limits of agreement, defined as 1.96 times the standard deviation of the mean difference. The effect of both lung volume correction and breath hold reproducibility was determined. The limits of agreement for uncorrected CT air trapping measurements were -15.0 to 11.7 % (EXP{sub -856}) and -9.8 to 8.0 % (E/I-ratio{sub MLD}). Good breath hold reproducibility significantly narrowed the limits for EXP{sub -856} (-10.7 to 7.5 %, P = 0.002), but not for E/I-ratio{sub MLD} (-9.2 to 7.9 %, P = 0.75). Statistical lung volume correction did not improve the limits for EXP{sub -856} (-12.5 to 8.8 %, P = 0.12) and E/I-ratio{sub MLD} (-7.5 to 5.8 %, P = 0.17). Quantitative air trapping measures on low-dose CT of heavy smokers show considerable variation on repeat CT examinations, regardless of lung volume correction or reproducible breath holds. (orig.)

  1. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  2. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  3. CT findings at lupus mesenteric vasculitis

    International Nuclear Information System (INIS)

    Ko, S.F.; Lee, T.Y.; Cheng, T.T.; Ng, S.H.; Lai, H.M.; Cheng, Y.F.; Tsai, C.C.

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.)

  4. CT findings at lupus mesenteric vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, S.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lee, T.Y. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Cheng, T.T. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Ng, S.H. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lai, H.M. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Cheng, Y.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Tsai, C.C. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan)

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.).

  5. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  6. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  7. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  8. CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Sai, H; Kawamoto, S; Morimoto, K [Osaka Univ. (Japan). Faculty of Medicine

    1982-06-01

    CT was investigated in 125 cases of hepatocelluar carcinoma and 47 cases of metastatic hepatic neoplasm. The entire contour of each tumor was traced and the average CT value in the tumor was estimated. As a result, the CT value for hepatocellular carcinoma tended to be higher on plain CT and also after contrast enhancement. The CT findings seen frequently were as follows: capsule in 76 cases (60.8%) and septum in 67 cases (53.6%); tumor thrombus in portal vein in 39 cases (31.2%) and that in inferior vena cava in 3 cases (2.4%); localized enlargement of hepatic bile duct in 24 cases (19.2%). These findings were rarely seen in the cases of metastatic hepatic neoplasm. As a relatively outstanding feature of hepatic metastases, a double contour, like concentric circles or contour lines, with a relatively large inner circle or contour line, was found in 21 cases (44.7%). By paying attention to the change of CT value on contrast enhancement and the characteristic image of each case, hepatocellular carcinoma could be differentiated from metastatic hepatic neoplasm with high probability.

  9. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  10. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  11. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  12. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  13. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    Science.gov (United States)

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  14. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... or nurse at the time of the CT examination. If your child has a known contrast material ... be given to your child for the CT examination. top of page What does the CT equipment ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  17. CT diagnosis of acute spinal injury

    International Nuclear Information System (INIS)

    Ohhama, Mitsuru; Niimiya, Hikosuke; Kimura, Ko; Yamazaki, Gyoji; Nasu, Yoshiro; Shioya, Akihide

    1982-01-01

    CT pictures of 22 acute spinal injuries with damage of the spinal cord were evaluated. In the cases of spinal cord damage with bone injury, changes in the vertebral canal were fully observed by CT. In some of spinal cord damages without bone injury, narrowing of the vertebral canal was demonstrated by CT combined with CT myelography and reconstruction. Evaluation of CT number showed a high density area in damaged spinal cord in some cases. CT was thus considered to be useful as an adjunct diagnostic aid. (Ueda, J.)

  18. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  19. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  20. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  1. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  2. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  3. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  4. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  5. CT of laryngeal trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.

    1986-01-01

    Computed tomography has made a significant contribution to the radiologic assessment of the injured larynx. CT is an accurate, noninvasive modality that can rapidly diagnose both soft tissue and cartilaginous injuries. CT of the larynx involves a minimal degree of patient manipulation and discomfort and can be performed in conjunction with CT evaluation of intracranial or facial injuries. Conventional radiologic studies (anteroposterior and lateral soft tissue films of the neck, tomograms, or xerograms) are capable of demonstrating some cartilaginous fractures but are of limited value in defining the extent of soft tissue injury. In the acute trauma setting, laryngography is often technically difficult to perform because of patient discomfort and inability to cooperate. Although the overall experience is somewhat limited, CT appears to overcome many of the limitations of these conventional radiologic methods. The following is a discussion of the role of CT scanning in evaluating injuries to the larynx and cervical soft tissues

  6. Congenital bronchopulmonary malformation: CT histopathological correlation.

    Science.gov (United States)

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  7. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  8. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  9. CT diagnosis of hepatoma

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Yuji [Tokyo Univ. (Japan). Faculty of Medicine

    1982-04-01

    In hepatocellular carcinoma, present status of CT diagnosis was discussed. Hepatocellular carcinoma is sometimes imaged in same concentration as that of surrounding tissues, and the detection rate ranged from 79 to 94%. The rate of differential diagnosis between primary and metastatic carcinoma was only 83% (includes 22% of false diagnosis) using contrast enhancement. The rates of detection of hepatocellular carcinoma and metastatic one were also only 87% and 75%, respectively, even by the combined use of arterial infusion CT and dynamic CT. However, the CT images is reproducible, and is supplemented by the information of US. Thus, the combination of these methods is useful in diagnosing the presence, extension, and nature of liver carcinoma.

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What is Children's CT? What are some common uses of the procedure? How should we prepare for the CT scan? What does the CT equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  11. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  12. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  13. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  14. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  15. Acute pancreatitis: clinical vs. CT findings

    International Nuclear Information System (INIS)

    Hill, M.C.; Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-01-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months

  16. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  17. CT examination of the kidneys

    International Nuclear Information System (INIS)

    Handa, Youji; Ishida, Ken; Arita, Takeshi; Ishine, Kenji; Tezen, Takashi; Ohta, Nobuhiro

    1985-01-01

    Plain CT scanning of the kidney was performed in 16 patients with renal failure whose basic renal disorder had been not necessarily known beforehand. The findings of the CT examination were composed of renal atrophy of various degree (12 cases), cystic lesions (8 cases), polycystic renal disease (one case), nephrosclerosis (2 cases), hydronephrosis (2 cases), ureter and renal stones (one case), and normal CT profile (2 cases). Being based on these CT findings and other clinical informations, basic renal disorders could be either presumed or confirmed. It was concluded that plain CT scanning of the kidney was useful to decide a method of treatment and to estimate prognosis in patients with renal failure. (author)

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  19. Do SNOMED CT Relationships Qualify?

    NARCIS (Netherlands)

    Cornet, Ronald

    2008-01-01

    An important feature of SNOMED CT is post-coordination, which is enabled as SNOMED CT specifies refinability of target concepts of relationships. In this paper the use of refinable relationships in SNOMED CT is analysed, and the interplay between refinable and defining relationships. Refinability is

  20. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  1. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  2. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  3. Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

    Science.gov (United States)

    Potretzke, Theodora A; Brace, Christopher L; Lubner, Meghan G; Sampson, Lisa A; Willey, Bridgett J; Lee, Fred T

    2015-04-01

    To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images. © RSNA, 2014.

  4. Chest Computed Tomography (CT) Immediately after CT-Guided Transthoracic Needle Aspiration Biopsy as a Predictor of Overt Pneumothorax

    Science.gov (United States)

    Noh, Tae June; Lee, Chang Hoon; Kang, Young Ae; Kwon, Sung-Youn; Yoon, Ho-Il; Kim, Tae Jung; Lee, Kyung Won; Lee, Jae Ho

    2009-01-01

    Background/Aims This study examined the correlation between pneumothorax detected by immediate post-transthoracic needle aspiration-biopsy (TTNB) chest computed tomography (CT) and overt pneumothorax detected by chest PA, and investigated factors that might influence the correlation. Methods Adult patients who had undergone CT-guided TTNB for lung lesions from May 2003 to June 2007 at Seoul National University Bundang Hospital were included. Immediate post-TTNB CT and chest PA follow-up at 4 and 16 hours after CT-guided TTNB were performed in 934 patients. Results Pneumothorax detected by immediate chest CT (CT-pneumothorax) was found in 237 (25%) and overt pneumothorax was detected by chest PA follow-up in 92 (38.8%) of the 237 patients. However, overt pneumothorax was found in 18 (2.6%) of the 697 patients without CT-pneumothorax. The width and depth of CT-pneumothorax were predictive risk factors for overt pneumothorax. Conclusions CT-pneumothorax is very sensitive for predicting overt pneumothorax, and the width and depth on CT-pneumothorax are reliable risk factors for predicting overt pneumothorax. PMID:19949733

  5. Dynamic CT of the renal parenchyma

    International Nuclear Information System (INIS)

    Ohyama, Yukio; Imanishi, Yoshimasa; Ishikawa, Tohru; Fujii, Masamichi; Uji, Teruyuki

    1985-01-01

    Normal renal dynamic CT findings of 57 cases were analysed in termes of sequential change of renal parenchymal CT image. Cortex, outer medulla and inner medulla were delineated and their sequential CT image was well correlated with the anatomicophysiological character of the kidney. Dynamic CT of 32 abnormal cases showed abnormal sequential CT findings explaining the mechanism of the abnormalities. Especially, delayed enhancement of renal cortex was noted in 17 of 19 kidneys with arterial obstruction and delayed enhancement of renal medulla in 22 of 25 cases with renal dysfunction. Compaired with excretory urography in 11 cases with renal dysfunction, advantage of dynamic CT were noted. (author)

  6. Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

    Science.gov (United States)

    Yeh, Benjamin M; FitzGerald, Paul F; Edic, Peter M; Lambert, Jack W; Colborn, Robert E; Marino, Michael E; Evans, Paul M; Roberts, Jeannette C; Wang, Zhen J; Wong, Margaret J; Bonitatibus, Peter J

    2017-04-01

    The introduction of spectral CT imaging in the form of fast clinical dual-energy CT enabled contrast material to be differentiated from other radiodense materials, improved lesion detection in contrast-enhanced scans, and changed the way that existing iodine and barium contrast materials are used in clinical practice. More profoundly, spectral CT can differentiate between individual contrast materials that have different reporter elements such that high-resolution CT imaging of multiple contrast agents can be obtained in a single pass of the CT scanner. These spectral CT capabilities would be even more impactful with the development of contrast materials designed to complement the existing clinical iodine- and barium-based agents. New biocompatible high-atomic number contrast materials with different biodistribution and X-ray attenuation properties than existing agents will expand the diagnostic power of spectral CT imaging without penalties in radiation dose or scan time. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    International Nuclear Information System (INIS)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan

    2012-01-01

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED adj ). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED adj between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED adj that differed by up to 44% from effective dose estimates that were not

  8. CT diagnostic significance of tuboovarian abscess

    International Nuclear Information System (INIS)

    Du Tieqiao; Dong Jie; Xu Quanying; An Haiqin; Sang Chunyu

    2006-01-01

    Objective: To analyze computed tomographic (CT) imaging features of tuboovarian abscess as well as to discuss CT diagnostic significance. Methods: Ten patients with tuboovarian abscess were performed CT enhancing scans. Results: Ten patients manifested thick-walled, cystic-solid complex adnexal mass and indistinct margins on CT imaging. Internal thick septations and layered enhancement of the mass border on CT contrast images were common. Associated findings of CT included thickening of' the uterosacral ligaments in 9 of 10 patients, increased attenuation of the presacral and perirectal fat secondary to edema in 9 patients, serpiginous structure corresponding to a dilated, pus-filled fallopian tube in 6 patients and fluid-filled within uterine cavity in 4 patients. On CT scans, the inflammatory infiltration of adnexal abscesses involved pelvic structure included adhesion with borders of uterus in 9 patients, adhesion with rectal or sigmoid in 4 patients and pelvic wall or bowel loop in 3 patients. Two cases with peritoneal thicken showed ascites on CT images and right adnexal tuboovarian abscess in 2 patients were associated with appendicitis. Conclusion: CT can reveal pelvic adjacent organs involvement or adhesion and inflammatory infihration of pelvic floor soft-tissues or fascial planes except showing cystic solid complex mass of adnexal location so that indicating characteristics and the extent of the suspected pelvic inflammatory diseases. CT can be valuable in difficult cases of gynecologic infective diseases. (authors)

  9. Correlation of CT perfusion and CT volumetry in patients with Alzheimers disease

    International Nuclear Information System (INIS)

    Czarnecka, A.; Zimny, A.; Sasiadek, M.

    2010-01-01

    Background: Both brain atrophy and decrease of perfusion are observed in dementive diseases. The aim of the study was to correlate the results of brain perfusion CT (pCT) and CT volumetry in patients with Alzheimers disease (AD). Material/Methods: Forty-eight patients with AD (mean age of 71.3 years) underwent brain pCT and CT volumetry. The pCT was performed at the level of basal ganglia after the injection of contrast medium (50 ml, 4 ml/sec.) with serial scanning (delay 7 sec, 50 scans, 1 scan/sec). Volumetric measurements were carried out on the basis of source images, with the use of a dedicated CT software combined with manual outlining of the regions of interest in extracerebral and intraventricular CSF spaces. Perfusion parameters of the cerebral blood flow (CBF) and cerebral blood volume (CBV) from the grey matter of frontal and temporal as well as basal ganglia were compared statistically with the volumetric measurements of frontal and temporal cortical atrophy as well as subcortical atrophy. Results: A statistically significant positive correlation was found between the values of CBF and CBV in the basal ganglia and the volumes of the lateral and third ventricles. The comparison of CBF and CBV results with the volumetric measurements in the areas of the frontal and temporal lobes showed mostly negative correlations, but none of them was of statistical significance. Conclusions: In patients with AD, the degree of cortical atrophy is not correlated with the decrease of perfusion in the grey matter and subcortical atrophy is not correlated with the decrease of perfusion in the basal ganglia region. It suggests that functional and structural changes in AD are not related to each other. (authors)

  10. Brain tumor and CT, 1. Relationship between the consistency of a brain tumor and the CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, N.; Katada, K.; Shinomiya, Y.; Sano, H.; Kanno, T. (Fujita Gakuen Univ., School of Medicine, Toyoake, Aichi (Japan))

    1981-08-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively. Twenty-seven cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor.

  11. CT evaluation of acetabular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Piazza, P; Girelli, G; Coran, F; Lutman, M

    1986-01-01

    The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Stroke Brain Tumors Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Computed Tomography (CT) - ...

  13. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  14. Results and complications of CT-guided biopsy with CT fluoroscopy

    International Nuclear Information System (INIS)

    Saika, Yoshinori; Ogura, Yasuharu; Doi, Kenji; Misaki, Toshimasa; Shimizu, Masashi; Narabayashi, Isamu

    2002-01-01

    We studied the results and complications of CT-guided biopsy with CT fluoroscopy performed 66 lesions in 64 patients from March 1999 to February 2001. In addition to the conventional procedure of CT-guided biopsy, we use CT fluoroscopy for confirmation of the location of the tip of the biopsy needle and the accurate contact, in some cases, at the time of puncturing. Examination results showed malignancy in 36 lesions and benign findings in 30 lesions. The sensitivity was 85.7%, specificity was 100.0%, and accuracy was 90.9%. Pneumothorax occurred in 20 out of 64 patients (31.3%). In a study on 26 small lesions (≤2 cm) in 25 patients, the sensitivity was 81.8%, specificity was 100.0%, accuracy was 92.3%. Pneumothorax occurred in 12 out of 25 patients (48.0%), more frequently than in patients with large lesions. In a study on 6 false negative cases, they tended to be intrapulmonary on location, small in diameter, and far from the skin puncture point. Examination results were satisfactory, especially in terms of accuracy in small lesions (≤2 cm). However, when the lesions were small, pneumothorax occurred frequently (48.0%). (author)

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  16. CT diagnosis of cystic ovarian lesions

    International Nuclear Information System (INIS)

    Iio, Kazuto; Shinmura, Ryoji; Arima, Naomi; Yamada, Eiichiro; Ohkubo, Koichi; Nagata, Yukihiro

    1985-01-01

    CT was undertaken and CT numbers were measured in 47 patients with cystic ovarian lesions. CT features particularly for chocolate cyst revealed the uniform thickness of the whole cystic wall, findings suggesting adhesion to the surrounding organs, circular or oval shape, and higher CT numbers within the cyst than those in the other cystic ovarian lesions. However, because these features are not always observed in cases of chocolate cyst, one should not rely solely on CT findings in the diagnosis of chocolate cyst. (Namekawa, K.)

  17. Dynamic CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Nobuyuki; Shirato, Hiroki; Shinohara, Masahiro; Miyasaka, Kazuo; Morita, Yutaka; Irie, Goro

    1983-03-01

    We performed dynamic CT in 30 cases of hepatocellular carcinoma, and concluded as below. Detecting the stain in the early phase of the dynamic series, it is possible to make a diagnosis of hepatocellular carcinoma. The dynamic CT is effective in a case of small hepatocellular carcinoma in which it is difficult to gain an accurate diagnosis in the routine CT study. The dynamic CT is also effective in the differential diagnosis of hepatic lesions, as other hepatic lesions such as hemangioma and metastatic liver cancer show different patterns compared with hepatocellular carcinoma.

  18. (18)F-FDG PET-CT simulation for non-small-cell lung cancer: effect in patients already staged by PET-CT.

    Science.gov (United States)

    Hanna, Gerard G; McAleese, Jonathan; Carson, Kathryn J; Stewart, David P; Cosgrove, Vivian P; Eakin, Ruth L; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H; Young, V A Linda; O'Sullivan, Joe M; Hounsell, Alan R

    2010-05-01

    Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV(CT) to GTV(FUSED) was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  19. 18F-FDG PET-CT Simulation for Non-Small-Cell Lung Cancer: Effect in Patients Already Staged by PET-CT

    International Nuclear Information System (INIS)

    Hanna, Gerard G.; McAleese, Jonathan; Carson, Kathryn J.; Stewart, David P.; Cosgrove, Vivian P.; Eakin, Ruth L.; Zatari, Ashraf; Lynch, Tom; Jarritt, Peter H.; Young, V.A. Linda D.C.R.; O'Sullivan, Joe M.

    2010-01-01

    Purpose: Positron emission tomography (PET), in addition to computed tomography (CT), has an effect in target volume definition for radical radiotherapy (RT) for non-small-cell lung cancer (NSCLC). In previously PET-CT staged patients with NSCLC, we assessed the effect of using an additional planning PET-CT scan for gross tumor volume (GTV) definition. Methods and Materials: A total of 28 patients with Stage IA-IIIB NSCLC were enrolled. All patients had undergone staging PET-CT to ensure suitability for radical RT. Of the 28 patients, 14 received induction chemotherapy. In place of a RT planning CT scan, patients underwent scanning on a PET-CT scanner. In a virtual planning study, four oncologists independently delineated the GTV on the CT scan alone and then on the PET-CT scan. Intraobserver and interobserver variability were assessed using the concordance index (CI), and the results were compared using the Wilcoxon signed ranks test. Results: PET-CT improved the CI between observers when defining the GTV using the PET-CT images compared with using CT alone for matched cases (median CI, 0.57 for CT and 0.64 for PET-CT, p = .032). The median of the mean percentage of volume change from GTV CT to GTV FUSED was -5.21% for the induction chemotherapy group and 18.88% for the RT-alone group. Using the Mann-Whitney U test, this was significantly different (p = .001). Conclusion: PET-CT RT planning scan, in addition to a staging PET-CT scan, reduces interobserver variability in GTV definition for NSCLC. The GTV size with PET-CT compared with CT in the RT-alone group increased and was reduced in the induction chemotherapy group.

  20. Cardiac cone-beam CT

    International Nuclear Information System (INIS)

    Manzke, Robert

    2005-01-01

    This doctoral thesis addresses imaging of the heart with retrospectively gated helical cone-beam computed tomography (CT). A thorough review of the CT reconstruction literature is presented in combination with a historic overview of cardiac CT imaging and a brief introduction to other cardiac imaging modalities. The thesis includes a comprehensive chapter about the theory of CT reconstruction, familiarizing the reader with the problem of cone-beam reconstruction. The anatomic and dynamic properties of the heart are outlined and techniques to derive the gating information are reviewed. With the extended cardiac reconstruction (ECR) framework, a new approach is presented for the heart-rate-adaptive gated helical cardiac cone-beam CT reconstruction. Reconstruction assessment criteria such as the temporal resolution, the homogeneity in terms of the cardiac phase, and the smoothness at cycle-to-cycle transitions are developed. Several reconstruction optimization approaches are described: An approach for the heart-rate-adaptive optimization of the temporal resolution is presented. Streak artifacts at cycle-to-cycle transitions can be minimized by using an improved cardiac weighting scheme. The optimal quiescent cardiac phase for the reconstruction can be determined automatically with the motion map technique. Results for all optimization procedures applied to ECR are presented and discussed based on patient and phantom data. The ECR algorithm is analyzed for larger detector arrays of future cone-beam systems throughout an extensive simulation study based on a four-dimensional cardiac CT phantom. The results of the scientific work are summarized and an outlook proposing future directions is given. The presented thesis is available for public download at www.cardiac-ct.net

  1. How to choose PET-CT or CT in the diagnosis and staging of lung cancer. Practical experience in China

    International Nuclear Information System (INIS)

    Jiang, T.; Tao, X.; Liu, H.; Liu, S.; Zheng, X.

    2010-01-01

    How to use CT and PET-CT rationally to raise diagnosis, staging and prognostic assessment of lung cancer to a higher level at the best cost-effect ratio is a subject that Chinese clinicians and radiologists should face conscientiously. We review the rational application of CT and PET-CT in four aspects of lung cancer, including screening and detection, morphologic evaluation, haemodynamic or metabolic feature evaluation, and follow-up, staging and prognostic evaluation. As PET-CT is only available in class III-A hospitals today, CT is the most popular equipment in China. PET-CT is more valuable only in cases where CT presentation of lung cancer is atypical or difficult to determine, or in cases where the diagnosis of lung cancer has been initially confirmed, for which clinical staging and decision concerning on therapeutic regimens are needed. We also recommend the current strategies of CT and PET-CT managing of SPN in China. (orig.)

  2. CT number of the fatty liver

    International Nuclear Information System (INIS)

    Maeda, Hiroko; Kawai, Takeshi; Kanasaki, Yoshiki; Akagi, Hiroaki

    1981-01-01

    This report is studied on CT number and CT images of the eight cases with fatty liver. Five of these cases showed the reversal of densities of the liver and vessels. In these cases, the diagnoses of the fatty liver were easible. In other cases, the diagnoses were possible only by comparison of the CT number of the liver and spleen because the CT number of normal liver were higher than those of the spleen. In the results which we examined the correlation of the CT number and specific gravities of the blood, normal saline, distilled water, mayonnaise, eatable iol, ethyl alcohol and lard, we observed the linear relationship between CT number and specific gravities. And so, we think that the diagnosis of the fatty liver and the degree of fatty infiltration can be guessed by the CT number of the liver and spleen. (author)

  3. CT of Mirizzi syndrome

    International Nuclear Information System (INIS)

    Yamamoto, Shinichiro; Fukushima, Keisuke; Ishihara, Kenji; Hirano, Yutaka; Sano, Kaizo

    1983-01-01

    PTC or ERCP findings of four cases of Mirizzi syndrome were demonstrated. They consisted of a smooth stricture of the common hepatic duct, curved impressions of the duct and dilatation of proximal biliary radicles. CT could visualize the impacted stone in the neck of the gallbladder, dilatation of proximal common hepatic and intrahepatic duct. Absence of the dilatation of distal common bile duct could also be confirmed by CT, thus the diagnosis of Mirizzi syndrome might be possible by CT. (author)

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... multislice CT" or "multidetector CT," allow thinner slices to be obtained, resulting in more detail of the body, in a shorter period of time. Modern CT scanners are so fast that they can scan through large sections of the body in just a few seconds. Such speed is beneficial for ...

  5. Normal CT anatomy of the spine

    International Nuclear Information System (INIS)

    Quiroga, O.; Matozzi, F.; Beranger, M.; Nazarian, S.; Salamon, G.; Gambarelli, J.

    1982-01-01

    To analyse the anatomo-radiological correlation of the spine and spinal cord, 22 formalized, frozen anatomical specimens corresponding to different regions of the spinal column (8 cervical, 5 dorsal, and 9 lumbar) were studied by CT scans on axial, sagittal and coronal planes and by contact radiography after they were cut into anatomical slices in order to clarify the normal CT anatomy of the spinal column. The results obtained from CT patient scans, performed exclusively on the axial plane, were compared with those obtained from the anatomical specimens (both CT and contrast radiography). High resolution CT programs were used, enabling us to obtain better individualization of the normal structures contained in the spinal column. Direct sagittal and coronal sections were performed on the specimens in order to get further anatomo-radiological information. Enhanced CT studies of the specimens were also available because of the air already present in the subarachnoid spaces. Excellent visualization was obtained of bone structures, soft tissue and the spinal cord. High CT resolution of the spine appeares to be an excellent neuroradiological procedure to study the spine and spinal cord. A metrizamide CT scan is, however, necessary when a normal unenhanced CT scan is insufficient for diagnosis and when the spinal cord is not clearly visible, as often happens at the cervical level. Clinical findings are certainly very useful to ascertain the exact CT level and to limit the radiation exposure. (orig.)

  6. Diagnosis of gastric cancers by CT

    International Nuclear Information System (INIS)

    Zhu Jianbing; Gong Jianping; Huan Jian

    1999-01-01

    Forty two cases of gastric cancers were reviewed. The cancer had been examined by CT and was confirmed by operation and pathology. The diagnostic results of gastric cancers obtained by CT were compared with that from GI and fibro-gastroscopy examination. The results showed that the preparation of gastrointestinal tract before CT examination was important in the CT diagnosis of gastric cancer. CT in diagnosis of focus of gastric cancer and organ invasion is better than Gl and Fibro-gastroscopy and accuracy in diagnosis of gastric cancers is near to that of GI examination

  7. Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, Anne Grethe; Boecker Puhakka, Katriina [Department of Radiology R, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark); Hansen, Jolanta [Department of Medical Physics, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark)

    2002-11-01

    The aim of this study was to evaluate the radiation dose given by semicoronal CT of the sacroiliac joints (SIJs) in comparison with axial CT and conventional radiography. The total effective radiation doses given by serial contiguous semicoronal and axial CT, using 5-mm slices, 120 kV and 330 mAs, were determined by measurement of organ doses using an anthropomorphic Rando Alderson phantom paced with thermoluminescence dosimeters. The doses given by conventional antero-posterior (AP) and oblique projections of the SIJs were determined similarly. In a female the total effective dose by semicoronal CT was found to be more than six times lower than by axial CT and 2.5 times lower than the dose use to obtain a conventional AP radiograph, the values being 102, 678, and 255 {mu}Sv, respectively. The effective dose by semicoronal CT was only a little higher than the dose given to obtain two oblique radiographs. In a male with lead protection of the gonads the dose by semicoronal CT was four times lower than by axial CT, but higher than by conventional radiography. In conclusion, the effective dose by semicoronal CT of the SIJs is lower than by axial CT, and in females a semicoronal CT implies a lower effective radiation dose that used to obtain an AP radiograph. (orig.)

  8. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  9. CT in normal pressure hydrocephalus

    International Nuclear Information System (INIS)

    Fujita, Katsuzo; Nogaki, Hidekazu; Noda, Masaya; Kusunoki, Tadaki; Tamaki, Norihiko

    1981-01-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings. (author)

  10. CT manifestation of peritoneal metastasis

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Kang, Eun Young; Suh, Won Hyuck

    1989-01-01

    Peritoneal metastasis is frequent mode of dissemination of intraabdominal malignancies. Radiologic diagnosis of peritoneal metastasis has relied on indirect evidence on a barium UGI series and small bowel examination. With the advent of CT scanning, CT is capable of direct imaging of peritoneum. The sensitivity of CT in detecting peritoneal metastasis and CT manifestation of peritoneal metastatic lesions had reported occasionally, but rarely in Korea. So, authors illustrated the CT manifestation of peritoneal metastatic lesions in 32 cases of macroscopically proven cases in laparoscopy or laparotomy in Korea University Hae Wha Hospital during recent 4 years. The results are as follows. 1. Of total 32 cases, 18 cases were male and 14 cases were female. Age incidence was the most common in 6th decade. 2. The most common type of malignancy that cause peritoneal metastasis was the stomach cancer and next common type of malignancies were pancreas cancer in men and ovarian cancer in women. 3. Of total 32 cases of peritoneal metastasis which was confirmed by laparoscopy or laparotomy macroscopically, 23 cases (72%) were detected peritoneal thickening and/or omental pathology by CT, and the remaining 9 cases (28%) were not detected by CT. 4. Ascites was present in 19 cases (59%). 5. Parietal peritoneal thickening was present in 16 cases (50%) by CT and sheetlike pattern was the most common findings. The patterns of peritoneal thickening was relatively nonspecific and was not correlated with primary tumor type. 6. Tumor involvement of greater omentum by CT was present in 19 cases (59%). There were 7 cases of smudged appearance pattern, 6 cases of nodular pattern, 6 cases of omental cake pattern and no cystic mass pattern. The patterns of omental pathology was relatively nonspecific and was nor correlated with primary tumor type

  11. Helical CT defecography

    International Nuclear Information System (INIS)

    Ferrando, R.; Fiorini, G.; Beghello, A.; Cicio, G.R.; Derchi, L.E.; Consigliere, M.; Resasco, M.; Tornago, S.

    1999-01-01

    The purpose of this work is to investigate the possible role of Helical CT defecography in pelvic floor disorders by comparing the results of the investigations with those of conventional defecography. The series analyzed consisted of 90 patients, namely 62 women and 28 men, ranging in age 24-82 years. They were all submitted to conventional defecography, and 18 questionable cases were also studied with Helical CT defecography. The conventional examination was performed during the 4 standard phases of resting, squeezing, Valsalva and straining; it is used a remote-control unit. The parameters for Helical CT defecography were: 5 mm beam collimation, pitch 2, 120 KV, 250 m As and 18-20 degrees gantry inclination to acquire coronal images of the pelvic floor. The rectal ampulla was distended with a bolus of 300 mL nonionic iodinated contrast agent (dilution: 3g/cc). The patient wore a napkin and was seated on the table, except for those who could not hold the position and were thus examined supine. Twenty-second helical scans were performed at rest and during evacuation; multiplanar reconstructions were obtained especially on the sagittal plane for comparison with conventional defecographic images. Coronal Helical CT defecography images permitted to map the perineal floor muscles, while sagittal reconstructions provided information on the ampulla and the levator ani. To conclude, Helical CT defecography performed well in study of pelvic floor disorders and can follow conventional defecography especially in questionable cases [it

  12. Helical CT imaging of clinically suspected appendicitis: Correlation of CT and histological findings

    International Nuclear Information System (INIS)

    Wong, S.K.; Chan, L.P.; Yeo, A.

    2002-01-01

    PURPOSE: The diagnosis of appendicitis is traditionally made on the basis of clinical findings supported by laboratory results. The aim of our study was to determine the accuracy and feasibility of using a relatively new technique of computed tomography (CT) using only colonic contrast medium. MATERIALS AND METHODS: A total of 50 patients clinically diagnosed as having appendicitis were prospectively examined before surgery with thin-collimation helical CT from the L3 level to the acetabular roof with only rectally administered colon contrast medium. The hard copy CT images were reviewed jointly by two radiologists and a consensus was reached for each patient. The results were then compared with the surgical and histological findings at appendicectomy. RESULTS: There were 35 true-positives, one false-positive, 12 true-negatives and two false-negatives for CT. This yielded an accuracy of 94%, sensitivity of 95%, specificity of 92%, positive predictive value of 97% and negative predictive value of 86%. The appendix was identified in 45 patients (90%) and obscured by an inflammatory mass in the remaining five. An alternative diagnosis was found in 10 of 12 normal CT examinations (83%). CONCLUSION: Helical CT with rectal contrast medium is a quick, well tolerated and accurate test to diagnose appendicitis. It can offer alternative, possibly non-surgical diagnosis in patients who would otherwise have undergone laparotomy. Wong, S.K. et al. (2002)

  13. CT and MRT in mediastinal and hilar masses. CT und MRT bei mediastinalen und hilaeren Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Kramer, J.; Stiglbauer, R.; Wimberger, D.; Imhof, H. (Vienna Univ. (Austria). Klinik fuer Radiodiagnostik Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Metz, V. (Vienna Univ. (Austria). 2. Chirurgische Klinik)

    1990-11-01

    Thirty-eight patients with mediastinal and/or hilar masses were imaged by computed tomography (CT) and magnetic resonance imaging (MRI). Results were analyzed retrospectively regarding the ability to demonstrate the masses, their number, size, definition, location and tissue characteristics. CT and MRI showed equivalent results in 32 cases; additional information was obtained in two patients by CT, in four patients by MRI. In view of the specific advantages and limitations of both CT and MRI we believed that in patients with mediastinal and/or hilar masses, contrast enhanced CT remains the procedure of choice after performing plain chest radiographs; in certain cases MRI will prove useful for further evaluation. (orig.).

  14. CT diagnosis of rectal cancer

    International Nuclear Information System (INIS)

    Kanda, Hiroshi; Hachisuka, Kitao; Yamaguchi, Akihiro

    1986-01-01

    Preoperative diagnosis of the depth of invasion and lymph node metastasis of rectal cancer were studied using the findings of computed tomography (CT). Of one hundred and four cases operated on for rectal cancer over a period of 32 months, thirty five cases were examined by CT with the use of olive oil enema and contrast enhancement using a 60 % Conray drip infusion with reference to the histological findings. For direct invasion into the wall, the diagnoses by CT were coincident with microscopic findings in 75 % of cancers of the rectosigmoid, in 75 % of the upper rectum and in 84 % of the lower rectum. Of all cases, 28 (80 %) were diagnosed correctly. As to local lymph node metastasis, 74 % of all diagnoses by CT corresponded with the histological diagnosis. Moreover, seventeen cases were evaluated for lateral lymph node metastasis, and the diagnostic accuracy by CT was 88 %. In conclusion, preoperative CT evaluation of the extension into the rectal wall and lymph node metastasis in rectal cancer was considesed useful. (author)

  15. CT features of appendiceal mucocele

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Won Jong; Byun, Jae Young; Jung, Jung Im; Lee, Hae Gyu; Park, Young Ha; Shin, Kyung Sub [Catholic University Medical College, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the usefulness of CT features of appendiceal mucocele in the diagnosis and evaluation of complications. We retrospectively reviewed CT findings and compared with operative findings in 7 cases of pathologically proven appendiceal mucocele. CT findings such as location and extent of the lesion, tissue density, thickness or calcification of the wall, presence of adjacent inflammatory infiltration, and visualization of normal vermiform appendix were analyzed. Appendiceal mucocele was found as homogeneous low density cystic mass adjacent to the cecum, which has no surrounding inflammatory infiltration except in one case of perforation and one case of intussusception. Mean CT number measured in 4 cases was 21 Hounsfield unit. Thin curvilinear calcifications were noted along the cystic wall in 2 cases. Normal vermiform appendix couldn't be demonstrated in all cases. Appendiceal mucocele is characterized by homogeneously low density and thin walled cystic tumor adjacent to cecum without surrounding inflammatory infiltration, and absence of normal vermiform appendix on CT. Therefore, CT is valuable in preventing operative complications of appendiceal mucocele.

  16. PET/CT. Dose-escalated image fusion?

    International Nuclear Information System (INIS)

    Brix, G.; Beyer, T.

    2005-01-01

    Clinical studies demonstrate a gain in diagnostic accuracy by employing combined PET/CT instead of separate CT and PET imaging. However, whole-body PET/CT examinations result in a comparatively high radiation burden to patients and thus require a proper justification and optimization to avoid repeated exposure or over-exposure of patients. This review article summarizes relevant data concerning radiation exposure of patients resulting from the different components of a combined PET/CT examination and presents different imaging strategies that can help to balance the diagnostic needs and the radiation protection requirements. In addition various dose reduction measures are discussed, some of which can be adopted from CT practice, while others mandate modifications to the existing hard- and software of PET/CT systems. (orig.)

  17. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  18. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  19. Three-dimensional-CT imaging of colorectal disease with thin collimation helical CT scanning

    International Nuclear Information System (INIS)

    Ogura, Toshihiro; Koizumi, Koichi; Sakai, Tatsuya; Kai, Shunkichi; Takatsu, Kazuaki; Maruyama, Masakazu

    1998-01-01

    We have conducted research on three-dimensional (3D)-CT-colonoscopy with thin collimation helical CT scanning over the past three years. This has lately become a subject of special interest. 3D-CT-colonoscopy has three kinds of visualizing methods depending on the threshold setting of CT values. The first one is the virtual endoscopy method which is displayed in a similar fashion to colonoscopic images. The second one is the air image method using the air in the digestive tract as a contrast medium. The third one is the pseudo-tract method which has characteristics of both virtual endoscopy and the air image method and visualizes in a shape of the digestive tract. The image visualized by 3D-CT-colonoscopy is similar to that of conventional colonoscopy and barium enema study, which is obtained with minimal invasion to patients. Obvious advanced carcinomas were easily visualized, and even a small flat polyp measuring 5 mm in size, was able to be observed retrospectively. The characteristics of our method are that we can easily make an examination in a short time and with little dependence on expert technique. Also patients have little discomfort compared to that experienced during colonoscopy and barium enema study. Important features are as follows; long calculation time, insufficient air insufflation, fecal material in the patient''s bowel, whole abdominal scan, and spatial resolution. In the near future, a multislice CT scanner system will have ability to overcome these problems. Therefore, 3D-CT-colonoscopy might be applied in the future for first line examination as a mass screening for colorectal carcinoma. (author)

  20. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  1. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  2. Development of ''Eminence STARGATE'' PET/CT system

    International Nuclear Information System (INIS)

    Okazaki, Masato; Inoue, Yoshihiro; Amano, Masaharu

    2009-01-01

    A PET/CT system, the combination of a PET (Positron Emission Tomography) system with an X-ray CT system, has been widely used in recent years. Our newly developed ''Eminence STARGATE'' PET/CT system allows the PET gantry and the X-ray CT gantry to move independently. This advantage provides high flexibility for PET examination and X-ray CT examination and also eases a patient's psychological anxiety about closed spaces. The system has a 16-slice X-ray CT scanner. (author)

  3. CT findings in epileptic children

    International Nuclear Information System (INIS)

    Koide, Nobuo; Kimura, Shigeru; Watanabe, Jun; Haneda, Satoshi; Takebe, Yukinao

    1981-01-01

    CT findings in 43 children with generalized seizures (grand mal seizures) (GM group) and in 50 children with partial seizures (P group), classified according to clinical seizure type, were studied. 1) CT abnormalities were demonstrated in 19% (8/43) in GM group and in 40% (20/50) in P group, including localized CT abnormalities in 9.3% (4/43) and in 34% (17/50) respectively. CT abnormalities were found more frequently in cases with abnormal past histories and/or mental defects (MD) than in those without them. 2) In P group, localized CT abnormalities and generalized brain atrophy were observed in 13 and 7 cases respectively. In 40 cases with focal epileptic discharges (FED) in EEG, localized CT abnormalities were demonstrated in 23% (9/40). The sites of localized CT abnormalities corresponded in 73% (11/15) to the sites of focal suppression in EEG (i.e., slowing, low amplitude and lazy pattern) regardless of FED. 3) The bicaudate cerebro-ventricular index (B-CVI) in 19 cases in the normal control group over 2 years of age was 10.0 +- 1.2 (mean +- SD). Ventricular narrowing (VN), with B-CVI less than 8.2 (mean - 1.5 SD), was observed in 5, 17 and 27% in control, GM and P groups respectively, indicating more frequently in epileptic children than in normal controls. Seizures were well controlled in 85% (11/13) in VN group and in 70% (26/36) in normal ventricular group. Brain atrophy in CT findings to inspection was ascertained in all cases by measuring B-CVI. (author)

  4. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    International Nuclear Information System (INIS)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee

    2016-01-01

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone

  5. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  6. L’utilisation de quelques outils web 2.0 et la création de tâches actionnelles comme stratégie d’accompagnement dans le processus d’enseignement/ apprentissage de FLE

    Directory of Open Access Journals (Sweden)

    Fanny Janneth Baquero

    2015-09-01

    Full Text Available Cet article montre les résultats d’une étude de recherche sur l’utilisation de quelques outils web 2.0 sur une plateforme virtuelle comme stratégie d’accompagnement dans le processus d’enseignement/apprentissage du Français Langue Étrangère, désormais fle. Ce travail a pour objectif l’observation et l’analyse d’une plateforme virtuelle pour proposer des tâches actionnelles en nous servant des outils web 2.0, lesquels sont plus en accord avec un étudiant-acteur-social d’après la perspective actionnelle privilégiée par le Cadre Commun Européen de Référence pour l'Enseignement des Langues Étrangères.

  7. Die Digitalisierung der Energiewirtschaft: Potenziale und Herausforderungen der IKT-Branche für Utility 4.0

    Science.gov (United States)

    Aichele, Christian; Schönberger, Marius

    Energieunternehmen haben auf dem Weg zur digitalen Transformation noch viele Herausforderungen zu bewältigen. Ein besonderer Schwerpunkt liegt derzeit auf der Modernisierung der IT-Systeme. Ausgangspunkt hierzu ist, dass sich bei den Endkonsumenten Mobile Applikationen, Smartphones, Tablet-PCs oder Smart TVs einer immensen Beliebtheit erfreuen. Durch diese Technologien wird die physische und virtuelle Welt in immer weiter zunehmendem Maße miteinander verknüpft. Mobile Applikation können einen wahren Hype hervorrufen und Verhaltensweisen auch nachhaltig verändern (ein Beispiel hierfür ist Pokémon Go, eine App die ein virtuelles Spiel mit der realen Umgebung kombiniert und die erstmalig auch eingefleischte Zocker aus der Anonymität ihrer häuslichen Umgebung hervorlocken konnte und für analoge Bewegung im Freien sorgte).

  8. Automated size-specific CT dose monitoring program: Assessing variability in CT dose

    Energy Technology Data Exchange (ETDEWEB)

    Christianson, Olav; Li Xiang; Frush, Donald; Samei, Ehsan [Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States) and Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Clinical Imaging Physics Group, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Department of Physics, Duke University, Durham, North Carolina 27710 (United States); and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States)

    2012-11-15

    Purpose: The potential health risks associated with low levels of ionizing radiation have created a movement in the radiology community to optimize computed tomography (CT) imaging protocols to use the lowest radiation dose possible without compromising the diagnostic usefulness of the images. Despite efforts to use appropriate and consistent radiation doses, studies suggest that a great deal of variability in radiation dose exists both within and between institutions for CT imaging. In this context, the authors have developed an automated size-specific radiation dose monitoring program for CT and used this program to assess variability in size-adjusted effective dose from CT imaging. Methods: The authors radiation dose monitoring program operates on an independent health insurance portability and accountability act compliant dosimetry server. Digital imaging and communication in medicine routing software is used to isolate dose report screen captures and scout images for all incoming CT studies. Effective dose conversion factors (k-factors) are determined based on the protocol and optical character recognition is used to extract the CT dose index and dose-length product. The patient's thickness is obtained by applying an adaptive thresholding algorithm to the scout images and is used to calculate the size-adjusted effective dose (ED{sub adj}). The radiation dose monitoring program was used to collect data on 6351 CT studies from three scanner models (GE Lightspeed Pro 16, GE Lightspeed VCT, and GE Definition CT750 HD) and two institutions over a one-month period and to analyze the variability in ED{sub adj} between scanner models and across institutions. Results: No significant difference was found between computer measurements of patient thickness and observer measurements (p= 0.17), and the average difference between the two methods was less than 4%. Applying the size correction resulted in ED{sub adj} that differed by up to 44% from effective dose

  9. CT cystography

    International Nuclear Information System (INIS)

    Tsili, A.

    2012-01-01

    Full text: Cancer of the urinary bladder is one of the commonest urothelial neoplasms. Conventional cystoscopy remains the mainstay in the diagnosis of urinary bladder carcinomas. But it is an invasive and uncomfortable procedure, associated with complications. Computed tomographic (CT) virtual cystoscopy has been proposed as an alternative imaging modality with potential advantages in the detection of urinary bladder neoplasms and good patient acceptance. It is a minimally invasive technique, allowing imaging of the urinary bladder in multiple planes and a 360 0 view. CT cystoscopy provides information about the location, size and morphologic features of urinary bladder lesions, indicating appropriate areas for biopsy. It can be performed in cases in which conventional cystoscopy is not feasible, such as in the presence of urethral strictures, marked prostatic hypertrophy or active bleeding, and in cases in which cystoscopic findings are inconclusive. The technique can be used to evaluate areas of the urinary bladder difficult to evaluate with cystoscopy, such as the anterior bladder neck and narrowmouthed diverticula. Finally, virtual cystoscopy provides both intraluminal and extraluminal pathologic changes, so intravesical disease and exrtavesical extension can be evaluated in the same study. One of the limitations of this technique is the difficulty to demonstrate small-sized lesions. The introduction of multi-detector row CT (MDCT) scanners was a major technological advancement because among other things it substantially improves z-axis resolution by reducing section collimation and allowing the detection of very small lesions. The near isotropic or isotropic pixels achieved with a multidetector CT scanner, enable the creation of multiplanar reformatted images with a resolution very close to that of the axial images and three-dimensional (3D) renderings of outstanding quality. Transverse, multiplanar reformations and virtual endoscopic images are complementary

  10. FDG-PET/CT in oncology. German guideline

    International Nuclear Information System (INIS)

    Krause, B.J.; Beyer, T.; Bockisch, A.; Delbeke, D.; Kotzerke, J.; Minkov, V.; Reiser, M.; Willich, N.

    2007-01-01

    FDG-PET/CT examinations combine metabolic and morphologic imaging within an integrated procedure. Over the past decade PET/CT imaging has gained wide clinical acceptance in the field of oncology. This FDG-PET/CT guideline focuses on indications, data acquisition and processing as well as documentation of FDG-PET/CT examinations in oncologic patients within a clinical and social context specific to Germany. Background information and definitions are followed by examples of clinical and research applications of FDG-PET/CT. Furthermore, protocols for CT scanning (low dose and contrast-enhanced CT) and PET emission imaging are discussed. Documentation and reporting of examinations are specified. Image interpretation criteria and sources of errors are discussed. Quality control for FDG and PET/CT-systems, qualification requirements of personnel as well as legal aspects are presented. (orig.)

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... of CT Scanning of the Abdomen and Pelvis? What is CT Scanning of the Abdomen/Pelvis? Computed ... soft tissues and blood vessels. top of page What are some common uses of the procedure? This ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT of the Sinuses? CT is usually the first test ordered when a sinus tumor is suspected. ... Radiology (ACR) and the Radiological Society of North America (RSNA), comprising physicians with expertise in several radiologic ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  14. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the scanning. Any motion, whether breathing or body movements, can lead to artifacts on the images. This ... clinical problems. CT is less sensitive to patient movement than MRI. CT can be performed if you ...

  16. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner or may be over the weight limit—usually 450 pounds—for the moving table. CT ... type your comment or suggestion into the following text box: Comment: E-mail: Area code: Phone no: ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... CT scan, an experienced radiologist can diagnose many causes of abdominal pain or injury from trauma with ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  1. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector ... Safety page for more information about radiation dose. Women should always inform their physician and x-ray ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  8. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... benefits vs. risks? Benefits A CT scan is one of the safest means of studying the sinuses. ... CT scanning provides very detailed images of many types of tissue as well as the lungs, bones, ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. CT imaging ...

  11. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... can be performed if you have an implanted medical device of any kind, unlike MRI. CT imaging ...

  12. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of ...

  13. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... to a CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide ... clicking and whirring sounds as the CT scanner's internal parts, not usually visible to you, revolve around ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... Safety Images related to Computed Tomography (CT) - Head Videos related to Computed Tomography (CT) - Head Sponsored by ...

  15. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... When the image slices are reassembled by computer software, the result is a very detailed multidimensional view ... related to Computed Tomography (CT) - Abdomen and Pelvis Videos related to Computed Tomography (CT) - Abdomen and Pelvis ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... particularly the lungs, abdomen, pelvis and bones. A diagnosis determined by CT scanning may eliminate the need ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... medical device of any kind, unlike MRI. A diagnosis determined by CT scanning may eliminate the need ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging ...

  19. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT) of the abdomen and pelvis is a diagnostic imaging test used to help detect diseases of ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... actual CT scanning is performed. Depending on the type of CT scan, the machine may make several ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits A CT scan is one of the ... CT scans should have no immediate side effects. Risks There is always a slight chance of cancer ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... air-filled spaces within the bones of the face surrounding the nasal cavity. CT scanning is painless, ... and blood vessels. A CT scan of the face produces images that also show a patient's paranasal ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  9. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  10. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  11. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanner is typically a large, box-like machine with a hole, or short tunnel, in the ... Then, the table will move slowly through the machine as the actual CT scanning is performed. Depending ...

  14. Imaging of female pelvic malignancies regarding MRI, CT, and PET/CT. Pt. 2

    International Nuclear Information System (INIS)

    Alt, Celine D.; Kauczor, Hans-Ulrich; Hallscheidt, Peter; Brocker, Kerstin A.; Eichbaum, Michael; Sohn, Christof; Arnegger, Florian U.

    2011-01-01

    To compose diagnostic standard operating procedures for both clinical and imaging assessment for vulvar and vaginal cancer, for vaginal sarcoma, and for ovarian cancer. The literature was reviewed for diagnosing the above mentioned malignancies in the female pelvis. Special focus herein lies in tumor representation in MRI, followed by the evaluation of CT and PET/CT for this topic. MRI is a useful additional diagnostic complement but by no means replaces established methods of gynecologic diagnostics and ultrasound. In fact, MRI is only implemented in the guidelines for vulvar cancer. According to the current literature, CT is still the cross-sectional imaging modality of choice for evaluating ovarian cancer. PET/CT appears to have advantages for staging and follow-up in sarcomas and cancers of the ovaries. (orig.)

  15. FDG PET/CT Is Superior to Enhanced CT in Detecting Recurrent Subcentimeter Lesions in the Abdominopelvic Cavity in Colorectal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai Jeon; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Asan Medical Center, Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    This study aims to compare the performance of contrast enhanced computed tomography (CeCT) and 18 F fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in detecting small tumor implants and metastatic lymph nodes (LNs) in the abdominopelvic cavity in patients with colorectal cancer. We enrolled 16 patients who were clinically suspected of experiencing a recurrences (6 male, 10 female; mean age 61{+-}14 years). All subjects underwent CeCT and PET/CT, and the performance of these methods was compared with regard to detecting recurrences. The final diagnosis of a recurrence was made clinically. CeCT identified 38 lesions in 12 patients, all of which were detected by PET/CT. PET/CT found 27 additional lesions in 8 patients, comprising 9 seeding nodules (2 in the right upper quadrant of the abdomen and 7 in the pelvic cavity) and 18 LNs (2 celiac, 2 paraaortic, 2 hepatic hilar, 11 common iliac, 1 external iliac). Most additional lesions were located in the pelvic cavity (approximately 78% of seeding nodules that were detected solely by PET/CT was significantly higher compared with the CeCT and PET/CT confirmed nodules (5.5{+-}4.2 vs. 2.9{+-}2.5, p=0.03). The seeding nodules that were detected only by PET/CT were significantly smaller than the CeCT and PET/CT confirmed nodules (long axis:1.0{+-}0.3cm vs. 2.0{+-}1.1cm, p=0.001; short axis: 0.8{+-}0.3cm vs. 1.7{+-}0.9cm, p=0.001). Similarly, PET/CT only detected LNs were significantly smaller than CeCT and PET/CT identified LNs (0.7{+-}0.1cm vs. 2.3{+-}1.2cm, p<0.0001). PET/CT is superior to CeCT in detecting seeding nodules and metastatic LNs in patients with recurrent colorectal cancer. Specifically, PET/CT detects subcentimeter lesions in anatomically deformed pelvic cavities.

  16. Dynamic CT of hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Fujita, Nobuyuki; Shirato, Hiroki; Shinohara, Masahiro; Miyasaka, Kazuo; Morita, Yutaka; Irie, Goro

    1983-01-01

    We performed dynamic CT in 30 cases of hepatocellular carcinoma, and concluded as below. 1 Decting the stain in the early phase of the dynamic series, it is possible to make a diagnosis of hepatocellular carcinoma. 2 The dinamic CT is effective in a case of small hepatocellular carcinoma in which it is difficult to gain an accurate diagnosis in the routine CT study. 3 The dynamic CT is also effective in the differential diagnosis of hepatic lesions, as other hepatic lesions such as hemangioma and metastatic liver cancer show different patterns compared with hepatocellular carcinoma. (author)

  17. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  18. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  19. Skeletal scintigraphy and SPECT/CT in orthopedic imaging; Knochenszintigrafie und SPECT/CT bei orthopaedischen Fragestellungen

    Energy Technology Data Exchange (ETDEWEB)

    Klaeser, B.; Walter, M.; Krause, T. [Inselspital Bern (Switzerland). Universitaetsklinik fuer Nuklearmedizin

    2011-03-15

    Multi-modality imaging with SPECT-CT in orthopaedics combines the excellent sensitivity of scintigraphy with the morphological information of CT as a key for specific interpretation of findings in bone scans. The result is an imaging modality with the clear potential to prove of value even in a competitive setting dominated by MRI, and to significantly add to diagnostic imaging in orthopaedics. SPECT-CT is of great value in the diagnostic evaluation after fractures, and - in contrast to MRI - it is well suited for imaging in patients with osteosyntheses and metallic implants. In sports medicine, SPECT-CT allows for a sensitive and specific detection of osseous stress reactions before morphological changes become detectable by CT or MRI. In patients with osseous pain syndromes, actively evolving degenerative changes as a cause of pain can be identified and accurately localized. Further, particularly prospective diagnostic studies providing comparative data are needed to strengthen the position of nuclear imaging in orthopaedics and sports medicine and to help implementing SPECT/CT in diagnostic algorithms. (orig.)

  20. The stylohyoid chain: CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Uysal Ramadan, Selma, E-mail: uysalselma@yahoo.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Goekharman, Dilek, E-mail: gokharman@ttnet.net.t [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Pinar, E-mail: pkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kacar, Mahmut, E-mail: mkacar1961@gamil.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey); Kosar, Ugur, E-mail: ugurkosar@hotmail.co [Department of Radiology, Ankara Training and Research Hospital, Ankara 06590 (Turkey)

    2010-09-15

    We aimed in this report to discuss the embryology, anatomy, theories of ossification and symptoms, clinical presentation, and diagnosis of the stylohyoid chain (SHC) variations, together with the role of radiographs, computed tomography (CT) and three-dimensional (3D)-CT in showing these variations. Because CT/3D-CT additionally facilitates visualization of the entire SHC with different axes, it is the most valuable method for establishing the relationship between the SHC and the surrounding tissue. SHC variation can be discovered during CT performed for indications other than ossified SHC. It is important to diagnose whether or not the SHC is ossified, since one of the treatment procedures in ossified SHC is total excision. If the clinician and radiologist are aware of these variations observed in the SHC, patients with vague symptoms may be spared unnecessary investigations and may be properly diagnosed earlier.

  1. Choline-PET/CT for imaging prostate cancer; Cholin-PET/CT zur Bildgebung des Prostatakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Bernd Joachim [Klinik- und Poliklinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Treiber, U.; Schwarzenboeck, S.; Souvatzoglou, M. [Klinik fuer Urologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany)

    2010-09-15

    PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives are increasingly being used for imaging of prostate cancer. The value of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in biochemical recurrence of prostate cancer has been examined in many studies and demonstrates an increasing importance. Primary prostate cancer can be detected with moderate sensitivity using PET and PET/CT using [{sup 11}C]- and [{sup 18}F]-labelled choline derivatives - the differentiation between benign prostatic hyperplasia, prostatitis or high-grade intraepithelial neoplasia (HGPIN) is not always possible. At the present time [{sup 11}C]choline PET/CT is not recommended in the primary setting but may be utilized in clinically suspected prostate cancer with repeatedly negative prostate biopsies, in preparation of a focused re-biopsy. Promising results have been obtained for the use of PET and PET/CT with [{sup 11}C]- and [{sup 18}F]-labelled choline derivates in patients with biochemical recurrence. The detection rate of choline PET and PET/CT for local, regional, and distant recurrence in patients with a biochemical recurrence shows a linear correlation with PSA values at the time of imaging and reaches about 75% in patients with PSA > 3 ng/mL. At PSA values below 1 ng/mL, the recurrence can be diagnosed with choline PET/CT in approximately 1/3 of the patients. PET and PET/CT with [{sup 11}C]- and [{sup 18}F]choline derivates can be helpful for choosing a therapeutic strategy in the sense of an individualized treatment: since an early diagnosis of recurrence is crucial to the choice of optimal treatment. The localization of the site of recurrence - local recurrence, lymph node metastasis or systemic dissemination - has important influence on the therapy regimen. (orig.)

  2. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2010-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density is the most important physical property of voxel model. Traditionally, when creating the Monte Carlo input files, the average tissue parameters recommended in ICRP report were used to assign each voxel in the existing voxel models. However, as each tissue consists of many voxels in which voxels are different in their densities, the method of assigning average tissue parameters doesn't take account of the voxel's discrepancy, and can't represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the density of which was derived from CT number. In order to compare with the traditional method, we have constructed two models from a same cadaver specimen date set. A CT-based pelvic voxel model called Pelvis-CT model, was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model, was also constructed, the densities of which were taken from ICRP Publication. The CT images and color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometries. The results were compared with those of given in ICRP74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis-Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model were agreed well with that of ICRP74 data. (author)

  3. Construction of a voxel model from CT images with density derived from CT numbers

    International Nuclear Information System (INIS)

    Cheng Mengyun; Zeng Qin; Cao Ruifen; Li Gui; Zheng Huaqing; Huang Shanqing; Song Gang; Wu Yican

    2011-01-01

    The voxel models representing human anatomy have been developed to calculate dose distribution in human body, while the density and elemental composition are the most important physical properties of voxel model. Usually, when creating the Monte Carlo input files, the average tissue densities recommended in ICRP Publication were used to assign each voxel in the existing voxel models. As each tissue consists of many voxels with different densities, the conventional method of average tissue densities failed to take account of the voxel's discrepancy, and therefore could not represent human anatomy faithfully. To represent human anatomy more faithfully, a method was implemented to assign each voxel, the densities of which were derived from CT number. In order to compare with the traditional method, we constructed two models from the cadaver specimen dataset. A CT-based pelvic voxel model called Pelvis-CT model was constructed, the densities of which were derived from the CT numbers. A color photograph-based pelvic voxel model called Pelvis-Photo model was also constructed, the densities of which were taken from ICRP Publication. The CT images and the color photographs were obtained from the same female cadaver specimen. The Pelvis-CT and Pelvis-Photo models were both ported into Monte Carlo code MCNP to calculate the conversion coefficients from kerma free-in-air to absorbed dose for external monoenergetic photon beams with energies of 0.1, 1 and 10 MeV under anterior-posterior (AP) geometry. The results were compared with those of given in ICRP Publication 74. Differences of up to 50% were observed between conversion coefficients of Pelvis-CT and Pelvis- Photo models, moreover the discrepancies decreased for the photon beams with higher energies. The overall trend of conversion coefficients of the Pelvis-CT model agreed well with that of ICRP Publication 74 data. (author)

  4. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  5. CT appearance of splenosis

    Energy Technology Data Exchange (ETDEWEB)

    Mendelson, D.S.; Cohen, B.A.; Armas, R.R.

    1982-12-01

    Splenosis is an unusual complication of splenic trauma. The computed tomographic (CT) appearance of splenosis is described. One should consider this diagnosis when faced with a history of splenic trauma and multiple round or oval masses at CT.

  6. CT appearance of splenosis

    International Nuclear Information System (INIS)

    Mendelson, D.S.; Cohen, B.A.; Armas, R.R.

    1982-01-01

    Splenosis is an unusual complication of splenic trauma. The computed tomographic (CT) appearance of splenosis is described. One should consider this diagnosis when faced with a history of splenic trauma and multiple round or oval masses at CT

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... sinus cavities – hollow, air-filled spaces within the bones of the face surrounding the nasal cavity. CT ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ...

  8. CT images of gossypiboma

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee

    1994-01-01

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment

  9. CT images of gossypiboma

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Hae Jeong; Lim, Jong Nam; Choi, Young Chil; Park, Jeong Hee [College of Medicine, Kon-Kuk University, Seoul (Korea, Republic of)

    1994-04-15

    Surgical sponges retained after laparotomy can cause serious problem if they were not be identified in early state. In these circumstances abdominal CT yields the accurate diagnostic images. The purpose of this report is to present highly indicative findings permitting correct preoperative diagnosis of the gossypiboma. We experienced three cases in which CT showed the images sufficiently characteristic to suggest the correct preoperative diagnosis. We evaluated retrospectively the radiological images of gossypiboma confirmed by operation. Three patients were admitted due to palpable masses. Two female patients had medical histories of cesarean sections and a male patient had been operated due to malignant fibrous histiocytoma, previously. Abdominal CT scan of one case revealed huge ovoid hypodense mass with enhanced peripheral rim. Calcific spots and whirl-like stripes were noted within the lesion. Towel was found in pathologic specimen. CT images of two patients showed well-encapsulated, mixed fluid and soft tissue density mass with several gas bubbles. Surgical sponges were found within abscesses. The authors conclude that these characteristic CT findings and careful histories of surgery are very useful for correct pre-operative diagnosis and permit the guideline for the optimal plan of the surgical treatment.

  10. Perforated appendicitis: accuracy of CT diagnosis and correlation of CT findings with the length of hospital

    International Nuclear Information System (INIS)

    Siddiqui, H.A.; Afzal, S.

    2007-01-01

    To determine the sensitivity and specificity of CT findings in the differentiation of perforated from nonperforated appendicitis and correlate CT diagnosis with the length of hospital stay. The study included 70 patients who presented with right lower quadrant abdominal pain and underwent preoperative CT scan followed by appendectomy. Patients were divided into two groups of having perforated and nonperforated appendicitis on the basis of CT scan findings. The surgical and pathological reports combined were considered the reference standard for the diagnosis of perforated appendicitis. Various CT scan findings and average duration of hospital stay in days was compared by t-test. Twenty-six (37%) of 70 patients had perforated appendicitis. It was correctly identified on pre-operative CT scan in 18 patients. There were 18 true positive diagnoses, 43 true negative diagnoses, 1 false positive diagnosis and 8 false negative diagnoses which yielded a sensitivity of 69%, specificity of 97%, positive predictive value of 94% and negative predictive value of 84%. Mean length of hospital stay in perforated group was 6.3 days and 2.9 days in nonperforated group. Severe periappendiceal inflammation, periappendiceal and or abdominopelvic fluid and abscess were significantly associated with perforated appendicitis and with a significant longer hospital stay (p <.001). CT scan is 69% sensitive and 97% specific for the diagnosis of perforated appendicitis and constellation of CT findings can be used to select patients with perforated appendicitis for initial non-operative management. Presence of CT signs of significant appendiceal inflammation is independent predictor of longer hospital stay. (author)

  11. Unresectable colorectal liver metastases. Percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT); Nicht resektable kolorektale Lebermetastasen. Perkutane Ablation mittels CT-gesteuerter Hochdosisbrachytherapie (CT-HDBRT)

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Lutter, A.; Schnapauff, D.; Denecke, T.; Gebauer, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Hildebrandt, B. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Oncology; Puhl, G. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of General, Visceral and Transplantation Surgery; Wust, P. [Charite, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiation Oncology

    2014-06-15

    Purpose: To evaluate the clinical outcome of CT-guided high-dose-rate brachytherapy (CT-HDRBT) of unresectable colorectal liver metastases (CRLMs). Materials and Methods: Retrospective analysis of all consecutive patients with unresectable CRLMs treated with CT-HDRBT between January 2008 and November 2012. Treatment was performed by CT-guided catheter placement and high-dose-rate brachytherapy with an iridium-192 source. MRI follow-up was performed after 6 weeks and then every 3 months post-intervention. The primary endpoint was local tumor control (LTC); secondary endpoints included time to progression (TTP) and overall survival (OS). Results: 80 heavily pretreated patients with 179 metastases were available for MRI evaluation for a mean follow-up time of 16.9 months. The mean tumor diameter was 28.5 mm (range: 8 - 107 mm). No major complications were observed. A total of 23 (12.9%) local tumor progressions were observed. Lesions ≥ 4 cm in diameter showed significantly more local progression than smaller lesions (< 4 cm). 50 patients (62.5%) experienced systemic tumor progression. The median TTP was 6 months. 28 (43%) patients died during the follow-up period. The median OS after ablation was 18 months. Conclusion: CT-HDRBT is an effective technique for the treatment of unresectable CRLMs and warrants promising LTC rates compared to thermal ablative techniques. A combination with other local and systemic therapies should be evaluated in patients with lesions > 4 cm in diameter, in which higher progression rates are expected. (orig.)

  12. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  13. Monte Carlo dose calibration in CT scanner

    International Nuclear Information System (INIS)

    Yadav, Poonam; Ramasubramanian, V.; Subbaiah, K.V.; Thayalan, K.

    2008-01-01

    Computed Tomography (CT) scanner is a high radiation imaging modality compared to radiography. The dose from a CT examination can vary greatly depending on the particular CT scanner used, the area of the body examined, and the operating parameters of the scan. CT is a major contributor to collective effective dose in diagnostic radiology. Apart from the clinical benefits, the widespread use of multislice scanner is increasing radiation level to patient in comparison with conventional CT scanner. So, it becomes necessary to increase awareness about the CT scanner. (author)

  14. {sup 18}F-FDG PET/CT imaging versus dynamic contrast-enhanced CT for staging and prognosis of inflammatory breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Champion, Laurence; Edeline, Veronique; Giraudet, Anne-Laure; Wartski, Myriam [Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Service d' Oncologie Medicale, Saint-Cloud (France); Cherel, Pascal [Institut Curie, Hopital Rene Huguenin, Service de Radiologie, Saint-Cloud (France); Bellet, Dominique [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de medecine, Saint-Quentin-en-Yvelines (France)

    2013-08-15

    Inflammatory breast cancer (IBC) is the most aggressive type of breast cancer with a poor prognosis. Locoregional staging is based on dynamic contrast-enhanced (DCE) CT or MRI. The aim of this study was to compare the performances of FDG PET/CT and DCE CT in locoregional staging of IBC and to assess their respective prognostic values. The study group comprised 50 women (median age: 51 {+-} 11 years) followed in our institution for IBC who underwent FDG PET/CT and DCE CT scans (median interval 5 {+-} 9 days). CT enhancement parameters were net maximal enhancement, net early enhancement and perfusion. The PET/CT scans showed intense FDG uptake in all primary tumours. Concordance rate between PET/CT and DCE CT for breast tumour localization was 92 %. No significant correlation was found between SUVmax and CT enhancement parameters in primary tumours (p > 0.6). PET/CT and DCE CT results were poorly correlated for skin infiltration (kappa = 0.19). Ipsilateral foci of increased axillary FDG uptake were found in 47 patients (median SUV: 7.9 {+-} 5.4), whereas enlarged axillary lymph nodes were observed on DCE CT in 43 patients. Results for axillary node involvement were fairly well correlated (kappa = 0.55). Nineteen patients (38 %) were found to be metastatic on PET/CT scan with a significant shorter progression-free survival than patients without distant lesions (p = 0.01). In the primary tumour, no statistically significant difference was observed between high and moderate tumour FDG uptake on survival, using an SUVmax cut-off of 5 (p = 0.7 and 0.9), or between high and low tumour enhancement on DCE CT (p > 0.8). FDG PET/CT imaging provided additional information concerning locoregional involvement to that provided by DCE CT on and allowed detection of distant metastases in the same whole-body procedure. Tumour FDG uptake or CT enhancement parameters were not correlated and were not found to have any prognostic value. (orig.)

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. A ... bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams ...

  16. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits A CT scan is one of the safest ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  17. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... over time. top of page What are the benefits vs. risks? Benefits Viewing a CT scan, an experienced radiologist can ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional ... advantage of CT is its ability to image bone, soft tissue and blood vessels all at the same time. ...

  1. Interobserver Delineation variation using CT versus combined CT + MRI in intensity- modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Villeirs, G.M.; Verstraete, K.L.; Vaerenbergh, K. van; Vakaet, L.; Bral, S.; Claus, F.; Neve, W.J. de; Meerleer, G.O. de

    2005-01-01

    Purpose: to quantify interobserver variation of prostate and seminal vesicle delineations using CT only versus CT + MRI in consensus reading with a radiologist. Material and methods: the prostate and seminal vesicles of 13 patients treated with intensity-modulated radiotherapy for prostatic adenocarcinoma were retrospectively delineated by three radiation oncologists on CT only and on CT + MRI in consensus reading with a radiologist. The volumes and margin positions were calculated and intermodality and interobserver variations were assessed for the clinical target volume (CTV), seminal vesicles, prostate and three prostatic subdivisions (apical, middle and basal third). Results: using CT + MRI as compared to CT alone, the mean CTV, prostate and seminal vesicle volumes significantly decreased by 6.54%, 5.21% and 10.47%, respectively. More importantly, their standard deviations significantly decreased by 63.06%, 62.65% and 44.83%, respectively. The highest level of variation was found at the prostatic apex, followed by the prostatic base and seminal vesicles. Conclusion: addition of MRI to CT in consensus reading with a radiologist results in a moderate decrease of the CTV, but an important decrease of the interobserver delineation variation, especially at the prostatic apex. (orig.)

  2. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  3. CT scan findings of fungal pneumonia; Diagnose der Pilzpneumonie in der Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Heckmann, M.; Uder, M.; Bautz, W.; Heinrich, M. [Erlangen-Nuernberg Univ., Erlangen (Germany). Inst. fuer Diagnostische Radiologie

    2008-07-01

    The importance of fungal infection of the lung in immunocompromised patients has increased substantially during the last decades. Numerically the most patients are those with neutropenia, e.g. patients with malignancies or solid organ and stem cell transplantation, chemotherapy, corticosteroid use and HIV infection. Although fungal infections can occur in immunocompetent patients, their frequency in this population is rare. The clinical symptoms such as fever accompanied with non-productive cough are unspecific. In some patients progression to hypoxemia and dyspnea may occur rapidly. In spite of improved antifungal therapy morbidity and mortality of these infections are still high. Therefore an early and non-invasive diagnosis is very important. That is why CT and even better High-Resolution-CT (HR-CT) is a very important modality in examining immunocompromised patients with a probability of fungal infection. CT is everywhere available and, as a non-invasive method, able to give the relevant diagnose efficiently. This paper should give an overview about the radiologic findings and possible differential diagnosis of diverse pulmonary fungal infections in CT. Pneumonias caused by Aspergillus, Cryptococcus, Candida, Histoplasma, Mucor and Geotrichum capitatum are illustrated. (orig.)

  4. CT findings of the thymus

    International Nuclear Information System (INIS)

    Kang, Eun Young; Kim, Yun Hwan; Seol, Hae Young; Chung, Woun Kyun; Suh, Won Hyuck

    1987-01-01

    In 14 cases of normal and abnormal thymus proved surgically and histopathologically in korea University Hae Wha Hospital during recent 6 years, the clinical and CT findings were analyzed. 1. Of 14 cases, 2 cases were normal thymus, 5 cases were thymic hyperplasia, 4 cases were benign thymoma, 2 case were malignant thymoma and 1 case was thymic cyst. 2. Of 14 cases, 10 cases were associated with myasthenia gravis, and 7 of these 10 cases were 3rd to 5th decades females. Among 10 cases with myasthenia gravis. 5 cases were thymic hyperplasia, 1 case was benign thymoma, 2 cases were malignant thymoma, and 2 cases were normal thymus. 3. All 5 thymic hyperplasia were associated with myasthenia gravis. CT findings of thymic hyperplasia were normal in 4 cases and increased lobe thickness in 1 case. 4. Of 4 cases of benign thymoma, only 1 case was associated with myasthenia gravis, and all 4 cases were positive findings in CT scan. CT findings of benign thymoma were round or oval soft tissue mass in anterior mediastinum, and 1 case had punctuate calcifications. 5. Of 2 cases of malignant thymoma, all 2 cases were associated with myasthenia gravis and positive findings in CT scan. CT findings of malignant thymoma were anterior mediastinal soft tissue mass with obliteration of the normal fat planes surrounding great vessels. SVC compression, and pleural tumor implants. 6. CT yielded significant diagnostic information of differential diagnosis between thymoma and thymoma hyperplasia in myasthenia gravis patients. Also CT was highly sensitive test in detection of thymoma and determined the extent and invasiveness of thymoma.

  5. CT findings of the thymus

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Young; Kim, Yun Hwan; Seol, Hae Young; Chung, Woun Kyun; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1987-02-15

    In 14 cases of normal and abnormal thymus proved surgically and histopathologically in korea University Hae Wha Hospital during recent 6 years, the clinical and CT findings were analyzed. 1. Of 14 cases, 2 cases were normal thymus, 5 cases were thymic hyperplasia, 4 cases were benign thymoma, 2 case were malignant thymoma and 1 case was thymic cyst. 2. Of 14 cases, 10 cases were associated with myasthenia gravis, and 7 of these 10 cases were 3rd to 5th decades females. Among 10 cases with myasthenia gravis. 5 cases were thymic hyperplasia, 1 case was benign thymoma, 2 cases were malignant thymoma, and 2 cases were normal thymus. 3. All 5 thymic hyperplasia were associated with myasthenia gravis. CT findings of thymic hyperplasia were normal in 4 cases and increased lobe thickness in 1 case. 4. Of 4 cases of benign thymoma, only 1 case was associated with myasthenia gravis, and all 4 cases were positive findings in CT scan. CT findings of benign thymoma were round or oval soft tissue mass in anterior mediastinum, and 1 case had punctuate calcifications. 5. Of 2 cases of malignant thymoma, all 2 cases were associated with myasthenia gravis and positive findings in CT scan. CT findings of malignant thymoma were anterior mediastinal soft tissue mass with obliteration of the normal fat planes surrounding great vessels. SVC compression, and pleural tumor implants. 6. CT yielded significant diagnostic information of differential diagnosis between thymoma and thymoma hyperplasia in myasthenia gravis patients. Also CT was highly sensitive test in detection of thymoma and determined the extent and invasiveness of thymoma.

  6. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  7. 3D CT versus axial helical CT versus conventional tomography in the classification of acetabular fractures: A ROC analysis

    International Nuclear Information System (INIS)

    Kickuth, Ralph; Laufer, Ulf; Hartung, Guido; Gruening, Christian; Stueckle, Christoph; Kirchner, Johannes

    2002-01-01

    AIM: To assess the diagnostic power of three-dimensional computed tomography (3D CT), axial helical computed tomography (CT) and conventional tomography in the classification of acetabular fractures by interdisciplinary review. MATERIALS AND METHODS: Receiver operating characteristics (ROCs) were assessed for two radiologists and two surgeons blinded to the presence of acetabular fractures in an animal model (a total of 62 porcine hips, 40 of them with artificial acetabular fractures). Main target parameter was the diagnostic accuracy in the classification of the artificial fractures following Judet et al. RESULTS: ROC analysis for radiologists showed A z values of 0·83 for 3D CT, 0·81 for axial helical CT, and 0·78 for conventional tomography; differences between the three techniques were not significant (P = 0·46-0·73). A z values for the surgeons were 0·87 for 3D CT, 0·68 for axial helical CT, and 0·60 for conventional tomography; 3D CT was significantly better than axial helical CT (P = 0·01) and conventional tomography (P = 0·001). The differences between axial helical CT and conventional tomography were not significant (P = 0·37). CONCLUSION: Acetabular fractures are best classified by 3D CT, followed by axial helical CT and conventional tomography when assessed by surgeons. 3D CT did not provide any additional significant benefit in the classification performed by radiologists. Kickuth, R. et al. (2002)

  8. Cardiac pathologies incidentally detected with non-gated chest CT; Inzidentelle Pathologien des Herzens im Thorax-CT

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Axel; Kroepil, P.; Lanzman, R.S.; Moedder, U. [Inst. fuer Radiologie, Universitaetsklinikum Duesseldorf, Heinrich-Heine-Univ. (Germany); Choy, G.; Abbara, S. [Cardiovascular Imaging Section, Massachusetts General Hospital, Harvard Medical School (United States)

    2009-12-15

    Cardiac imaging using electrocardiogram-gated multi-detector computed tomography (MDCT) permits noninvasive diagnosis of congenital and acquired cardiac pathologies and has thus become increasingly important in the last years. Several studies investigated the incidence and relevance of incidental extracardiac structures within the lungs, mediastinum, chest wall, and abdomen with gated coronary CT. This resulted in the general acceptance of the review of extracardiac structures as a routine component of coronary CT interpretation. On the other hand radiologists tend to neglect pericardial and cardiac pathologies in non-gated chest CT, which is primarily performed for the evaluation of the respiratory system or for tumor staging. Since the introduction of multi-detector spiral CT technology, the incidental detection of cardiac and pericardial findings has become possible using non-gated chest CT. This article reviews the imaging appearances and differential diagnostic considerations of incidental cardiac entities that may be encountered in non-gated chest CT. (orig.)

  9. Multislice CT imaging of pulmonary embolism

    International Nuclear Information System (INIS)

    Schoepf, J.U.; Kessler, M.A.; Rieger, C.T.; Herzog, P.; Wiesgigl, S.; Becker, C.R.; Exarhos, D.N.; Reiser, M.F.

    2001-01-01

    In recent years CT has been established as the method of choice for the diagnosis of central pulmonary embolism (PE) to the level of the segmental arteries. The key advantage of CT over competing modalities is the reliable detection of relevant alternative or additional disease causing the patient's symptoms. Although the clinical relevance of isolated peripheral emboli remains unclear, the alleged poor sensitivity of CT for the detection of such small clots has to date prevented the acceptance of CT as the gold standard for diagnosing PE. With the advent of multislice CT we can now cover the entire chest of a patient with 1-mm slices within one breath-hold. In comparison with thicker sections, the detection rate of subsegmental emboli can be significantly increased with 1-mm slices. In addition, the interobserver correlation which can be achieved with 1-mm sections by far exceeds the reproducibility of competing modalities. Meanwhile use of multislice CT for a combined diagnosis of PE and deep venous thrombosis with the same modality appears to be clinically accepted. In the vast majority of patients who receive a combined thoracic and venous multislice CT examination the scan either confirms the suspected diagnosis or reveals relevant alternative or additional disease. The therapeutic regimen is usually chosen based on the functional effect of embolic vascular occlusion. With the advent of fast CT scanning techniques, also functional parameters of lung perfusion can be non-invasively assessed by CT imaging. These advantages let multislice CT appear as an attractive modality for a non-invasive, fast, accurate, and comprehensive diagnosis of PE, its causes, effects, and differential diagnoses. (orig.)

  10. PET/CT imaging in head and neck tumors

    International Nuclear Information System (INIS)

    Roedel, R.; Palmedo, H.; Reichmann, K.; Reinhardt, M.J.; Biersack, H.J.; Straehler-Pohl, H.J.; Jaeger, U.

    2004-01-01

    To evaluate the usefulness of combined PET/CT examinations for detection of malignant tumors and their metastases in head and neck oncology. 51 patients received whole body scans on a dual modality PET/CT system. CT was performed without i.v. contrast. The results were compared concerning the diagnostic impact of native CT scan on FDG-PET images and the additional value of fused imaging. From 153 lesions were 97 classified as malignant on CT and 136 on FDG/PET images, as suspicious for malignancy in 33 on CT and 7 on FDG-PET and as benign in 23 on CT and 10 on FDG-PET. With combined PET/CT all primary and recurrent tumors could be found, the detection rate in patients with unknown primary tumors was 45%. Compared to PET or CT alone the sensitivity, specifity and accuracy could be significantly improved by means of combined PET/CT. Fused PET/CT imaging with [F18]-FDG and native CT-scanning enables accurate diagnosis in 93% of lesions and 90% of patients with head and neck oncology. (orig.) [de

  11. CT findings in neonatal hypothermia

    International Nuclear Information System (INIS)

    Schulman, H.; Laufer, L.; Berginer, J.; Hertzanu, Y.; Hershkowitz, E.; Berenstein, T.; Sofer, S.; Maor, E.

    1998-01-01

    Background. Newborn infants are particularly prone to hypothermia, a condition with a high mortality. Objective. To study the CT brain patterns in infants with hypothermia and neurological symptoms. Materials and methods. We reviewed the brain CT of nine infants with neonatal hypothermia, multiple organ failure, seizures and coma. Results. Two infants had normal CT scans, acutely and at follow-up, and were clinically normal at follow-up. In seven infants, CT showed diffuse cerebral oedema, with reversal of the normal density relationship between grey and white matter and a relative increased density of the thalami, brainstem and cerebellum - the 'reversal sign'. In six surviving infants with severe developmental delay, follow-up CT revealed cerebral atrophy with multicystic encephalomalacia. Conclusions. The 'reversal sign' has been described in the abused child, birth asphyxia and anoxia due to drowning. Neonatal hypothermia is offered as a further cause. (orig.)

  12. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  13. CT findings in Reye syndrome

    International Nuclear Information System (INIS)

    Lee, Kil Woo; Lim, Hyo Keun; Choo, In Wook; Bae, Sang Hoon

    1990-01-01

    We present here the CT findings in 10 patients with Reye syndrome. Acute findings is diffuse cerebral swelling with or without parenchymal low density. The cerebral swelling gradually changed to atrophy. The parenchymal low density predisposes in Lt temporoparietal area. Contrast enhanced CT scan showed no additional finding, except 1 case. The hemorrhagic infarction which has not been reported previously was seen in 1 case and resulted in the most prominent sequela. The sequelae were developed in all atrophic cases. So, the brain CT may be useful in monitoring cerebral swelling, determining treatment plan in acute stage, and in presenting prognosis and sequelae on fellow up CT

  14. Virtuelle Fachbibliothek Sozialwissenschaften - Projektskizze

    OpenAIRE

    Kluck, Michael; Krause, Jürgen; Müller, Matthias N.O.; Schmiede, Rudi; Wenzel, H.; Winkler, Stefan; Meier, Wolfgang

    2000-01-01

    Das Projekt zielt auf die integrierte Bereitstellung sozialwissenschaftlicher Literaturinformationen aus verteilten und inhaltlich unterschiedlich erschlossenen Datenbeständen. In erster Linie sollen Probleme des inhaltlichen Zugriffs auf solch heterogene Dokumentenbestände gelöst werden.

  15. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... can help plan the safest and most effective surgery. CT of the sinuses is now widely available and is performed in a relatively short time, especially when compared to magnetic resonance imaging (MRI). CT scanning is painless, noninvasive and ...

  16. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  17. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    Science.gov (United States)

    Wu, T.-H.; Liang, C.-H.; Wu, J.-K.; Lien, C.-Y.; Yang, B.-H.; Huang, Y.-H.; Lee, J. J. S.

    2009-07-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18F-fluorodeoxyglucose (18F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  18. Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy

    International Nuclear Information System (INIS)

    Wu, T-H; Liang, C-H; Wu, J-K; Lien, C-Y; Yang, B-H; Lee, J J S; Huang, Y-H

    2009-01-01

    Hybrid positron emission tomography-computed tomography (PET-CT) system enhances better differentiation of tissue uptake of 18 F-fluorodeoxyglucose ( 18 F-FDG) and provides much more diagnostic value in the non-small-cell lung cancer and nasopharyngeal carcinoma (NPC). In PET-CT, high quality CT images not only offer diagnostic value on anatomic delineation of the tissues but also shorten the acquisition time for attenuation correction (AC) compared with PET-alone imaging. The linear accelerators equipped with the X-ray cone-beam computed tomography (CBCT) imaging system for image-guided radiotherapy (IGRT) provides excellent verification on position setup error. The purposes of our study were to optimize the CT acquisition protocols of PET-CT and to integrate the PET-CT and CBCT for IGRT. The CT imaging parameters were modified in PET-CT for increasing the image quality in order to enhance the diagnostic value on tumour delineation. Reproducibility and registration accuracy via bone co-registration algorithm between the PET-CT and CBCT were evaluated by using a head phantom to simulate a head and neck treatment condition. Dose measurement in computed tomography dose index (CTDI) was also estimated. Optimization of the CT acquisition protocols of PET-CT was feasible in this study. Co-registration accuracy between CBCT and PET-CT on axial and helical modes was in the range of 1.06 to 2.08 and 0.99 to 2.05 mm, respectively. In our result, it revealed that the accuracy of the co-registration with CBCT on helical mode was more accurate than that on axial mode. Radiation doses in CTDI were 4.76 to 18.5 mGy and 4.83 to 18.79 mGy on axial and helical modes, respectively. Registration between PET-CT and CBCT is a state-of-the-art registration technology which could provide much information on diagnosis and accurate tumour contouring on radiotherapy while implementing radiotherapy procedures. This novelty technology of PET-CT and cone-beam CT integration for IGRT may have a

  19. Percutaneous CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors in nonsurgical candidates; Perkutane CT-gesteuerte Hochdosis-Brachytherapie (CT-HDRBT) von primaeren und metastatischen Lungentumoren in nicht chirurgischen Kandidaten

    Energy Technology Data Exchange (ETDEWEB)

    Collettini, F.; Schnapauff, D.; Poellinger, A.; Denecke, T.; Banzer, J.; Golenia, M.J.; Gebauer, B. [Charite - Universitatesmedizin Berlin (Germany). Inst. fuer Radiologie; Wust, P. [Charite - Universitatesmedizin Berlin (Germany). Klinik fuer Strahlentherapie

    2012-04-15

    To evaluate the safety and efficacy of CT-guided high-dose brachytherapy (CT-HDRBT) ablation of primary and metastatic lung tumors. Between November 2007 and May 2010, all consecutive patients with primary or metastatic lung tumors, unsuitable for surgery, were treated with CT-HDRBT. Imaging follow-up after treatment was performed with contrast-enhanced CT at 6 weeks, 3 months and every 6 months after the procedure. The endpoints of the study were local tumor control and time to progression. The Kaplan-Meier method was used to estimate survival functions and local tumor progression rates. 34 procedures were carried out on 33 lesions in 22 patients. The mean diameter of the tumors was 33.3 mm (SD = 20.4). The first contrast-enhanced CT showed that complete ablation was achieved in all lesions. The mean minimal tumor enclosing dose was 18.9 Gy (SD = 2). Three patients developed a pneumothorax after the procedure. The mean follow-up time was 13.7 (3 - 29) months. 2 of 32 lesions (6.25 %) developed a local tumor progression. 8 patients (36.3 %) developed a distant tumor progression. After 17.7 months, 13 patients were alive and 9 patients had died. CT-HDRBT ablation is a safe and attractive treatment option for patients with lung malignancies and allows targeted destruction of tumor tissue with simultaneous preservation of important lung structures. Furthermore, CT-HDRBT is independent of the size of the lesion and its location within the lung parenchyma. (orig.)

  20. Serial CT Findings of Paragonimus Infested Dogs and the Micro-CT Findings of the Worm Cysts

    International Nuclear Information System (INIS)

    Lee, Chang Hyun; Im, Jung Gi; Goo, Jin Mo; Lee, Hyun Ju; Hong, Sung Tae; Shen, Cheng Hua; Chung, Doo Hyun; Son, Kyu Ri; Chang, Jung Min; Eo, Hong

    2007-01-01

    To investigate the serial CT findings of Paragonimus westermani infected dogs and the microscopic structures of the worm cysts using Micro-CT. This study was approved by the committee on animal research at our institution. Fifteen dogs infected with P. westermani underwent serial contrast-enhanced CT scans at pre-infection, after 10 days of infection, and monthly thereafter until six months for determining the radiologic-pathologic correlation. Three dogs (one dog each time) were sacrificed at 1, 3 and 6 months, respectively. After fixation of the lungs, both multi-detector CT and Micro-CT were performed for examining the worm cysts. The initial findings were pleural effusion and/or subpleural groundglass opacities or linear opacities at day 10. At day 30, subpleural and peribronchial nodules appeared with hydropneumothorax and abdominal or chest wall air bubbles. Cavitary change and bronchial dilatation began to be seen on CT scan at day 30 and this was mostly seen together with mediastinal lymphadenopathy at day 60. Thereafter, subpleural ground-glass opacities and nodules with or without cavitary changes were persistently observed until day 180. After cavitary change of the nodules, the migratory features of the subpleural or peribronchial nodules were seen on all the serial CT scans. Micro-CT showed that the cyst wall contained dilated interconnected tubular structures, which had communications with the cavity and the adjacent distal bronchus. The CT findings of paragonimiasis depend on the migratory stage of the worms. The worm cyst can have numerous interconnected tubular channels within its own wall and these channels have connections with the cavity and the adjacent distal bronchus

  1. Clinical application of CT and CT-guided percutaneous transthoracic needle biopsy in patients with indeterminate pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Luciana Vargas; Souza Júnior, Arthur Soares, E-mail: fabianonatividade@terra.com.br [Rio Preto-Ultra-X Radiological Diagnosis Institute, São José do Rio Preto, SP (Brazil)

    2014-07-15

    Objective: To investigate the clinical application of CT and CT-guided percutaneous transthoracic needle biopsy (CT-PTNB) in patients with indeterminate pulmonary nodules (IPNs). Methods: We retrospectively studied 113 patients with PNs undergoing CT and CT-PTNB. Variables such as gender, age at diagnosis, smoking status, CT findings, and CT-PTNB techniques were analyzed. Data analysis was performed with the Student's t-test for independent samples the chi-square test, and normal approximation test for comparison of two proportions. Results: Of the 113 patients studied, 68 (60.2%) were male and 78 (69%) were smokers. The diameter of malignant lesions ranged from 2.6 cm to 10.0 cm. Most of the IPNs (85%) were located in the peripheral region. The biopsied IPNs were found to be malignant in 88 patients (77.8%) and benign in 25 (22.2%). Adenocarcinoma was the most common malignant tumor, affecting older patients. The IPN diameter was significantly greater in patients with malignant PNs than in those with benign IPNs (p < 0.001). Having regular contour correlated significantly with an IPN being benign (p = 0.022), whereas spiculated IPNs and bosselated IPNs were more often malignant (in 50.7% and 28.7%, respectively). Homogeneous attenuation and necrosis were more common in patients with malignant lesions (51.9% and 26.9%, respectively). Conclusions: In our sample, CT and CT-PTNB were useful in distinguishing between malignant and benign IPNs. Advanced age and smoking were significantly associated with malignancy. Certain CT findings related to IPNs (larger diameter, spiculated borders, homogeneous attenuation, and necrosis) were associated with malignancy. (author)

  2. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT scan can be reformatted ... of data to create two-dimensional cross-sectional images of your body, which are then displayed on a monitor. CT ...

  6. CT urography and hematuria

    DEFF Research Database (Denmark)

    Bretlau, Thomas; Hansen, Rasmus H; Thomsen, Henrik S

    2015-01-01

    BACKGROUND: Computed tomography (CT) urography is now used in the work-up of patients with hematuria. The dose of contrast medium and radiation varies considerably between the different CT protocols. PURPOSE: To study the disease prevalence in a consecutive group of patients with hematuria...

  7. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... about tumors of the nasal cavity and sinuses. plan for surgery by defining anatomy. top of page How should ... for sinusitis. CT of the sinuses can help plan the safest and most effective surgery. CT of the sinuses is now widely available ...

  8. Dual energy cardiac CT.

    Science.gov (United States)

    Carrascosa, Patricia; Deviggiano, Alejandro; Rodriguez-Granillo, Gastón

    2017-06-01

    Conventional single energy CT suffers from technical limitations related to the polychromatic nature of X-rays. Dual energy cardiac CT (DECT) shows promise to attenuate and even overcome some of these limitations, and might broaden the scope of patients eligible for cardiac CT towards the inclusion of higher risk patients. This might be achieved as a result of both safety (contrast reduction) and physiopathological (myocardial perfusion and characterization) issues. In this article, we will review the main clinical cardiac applications of DECT, that can be summarized in two core aspects: coronary artery evaluation, and myocardial evaluation.

  9. CT diagnosis in diseases of the breast

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the CT signs of breast diseases, and discuss the value of CT in the diagnosis of breast cancer and the axillary lymph node (LN) metastases. Materials and methods: Fifty three cases were reported, including breast cancer 30 cases and benign diseases 23 cases. CT were performed in all patients, 44 also had mammography examination. Results: (1) The CT appearance of breast cancer: round or irregular mass, spiculate border, duct retraction, involved Cooper's ligament, deformed adipose space etc. Benign hyperplasia: Irregular mass and symmetrical thickening of breast glands. Cystic hyperplasia: typically multiple, round, liquid-density mass. (2) CT was comparable to mammography in terms of differential diagnosis, however with breast mass located near the axilla or for evaluation of the thoracic wall. CT was superior to mammography. CT was also helpful in detecting LN metastases. Conclusion: CT is valuable in detecting and differentiating breast diseases as well as in the diagnosis of LN metastases

  10. Oncologic PET/CT: current status and controversies

    International Nuclear Information System (INIS)

    Siegel, B.A.; Dehdashti, F.

    2005-01-01

    The introduction of integrated PET/CT has dramatically increased the worldwide rate of growth for PET, predominantly for oncologic imaging with the glucose analog 18 F-fluorodeoxyglucose (FDG). A rapidly expanding body of literature demonstrates that the use FDG-PET/CT and the resultant ability to interpret coregistered and fused PET and CT images lead to improved observer confidence and improved diagnostic performance by comparison with PET alone, CT alone, and visually correlated PET and CT. The value of PET/CT is likely to be even greater with new PET radiopharmaceuticals under development, many of which produce PET images with even fewer anatomical landmarks than FDG images. PET/CT is also likely to lead to the resurrection of 18 F-fluoride as a principal agent for radionuclide bone imaging. There are a number of controversies related to PET/CT, including minimum training and experience requirements for interpreting physicians and defining new models for technical and professional reimbursement. (orig.)

  11. The sensitivity of computed tomography (CT) scans in detecting trauma: are CT scans reliable enough for courtroom testimony?

    Science.gov (United States)

    Molina, D Kimberley; Nichols, Joanna J; Dimaio, Vincent J M

    2007-09-01

    Rapid and accurate recognition of traumatic injuries is extremely important in emergency room and surgical settings. Emergency departments depend on computed tomography (CT) scans to provide rapid, accurate injury assessment. We conducted an analysis of all traumatic deaths autopsied at the Bexar County Medical Examiner's Office in which perimortem medical imaging (CT scan) was performed to assess the reliability of the CT scan in detecting trauma with sufficient accuracy for courtroom testimony. Cases were included in the study if an autopsy was conducted, a CT scan was performed within 24 hours before death, and there was no surgical intervention. Analysis was performed to assess the correlation between the autopsy and CT scan results. Sensitivity, specificity, positive predictive value, and negative predictive value were defined for the CT scan based on the autopsy results. The sensitivity of the CT scan ranged from 0% for cerebral lacerations, cervical vertebral body fractures, cardiac injury, and hollow viscus injury to 75% for liver injury. This study reveals that CT scans are an inadequate detection tool for forensic pathologists, where a definitive diagnosis is required, because they have a low level of accuracy in detecting traumatic injuries. CT scans may be adequate for clinicians in the emergency room setting, but are inadequate for courtroom testimony. If the evidence of trauma is based solely on CT scan reports, there is a high possibility of erroneous accusations, indictments, and convictions.

  12. CT findings in neonatal hypothermia

    Energy Technology Data Exchange (ETDEWEB)

    Schulman, H.; Laufer, L.; Berginer, J.; Hertzanu, Y. [Department of Radiology, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, P. O. Box 151, Beer-Sheva 84101 (Israel); Hershkowitz, E.; Berenstein, T.; Sofer, S. [Pediatric Intensive Care Unit, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva (Israel); Maor, E. [Department of Pathology, Soroka Medical Center, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva (Israel)

    1998-06-01

    Background. Newborn infants are particularly prone to hypothermia, a condition with a high mortality. Objective. To study the CT brain patterns in infants with hypothermia and neurological symptoms. Materials and methods. We reviewed the brain CT of nine infants with neonatal hypothermia, multiple organ failure, seizures and coma. Results. Two infants had normal CT scans, acutely and at follow-up, and were clinically normal at follow-up. In seven infants, CT showed diffuse cerebral oedema, with reversal of the normal density relationship between grey and white matter and a relative increased density of the thalami, brainstem and cerebellum - the `reversal sign`. In six surviving infants with severe developmental delay, follow-up CT revealed cerebral atrophy with multicystic encephalomalacia. Conclusions. The `reversal sign` has been described in the abused child, birth asphyxia and anoxia due to drowning. Neonatal hypothermia is offered as a further cause. (orig.) With 6 figs., 1 tab., 13 refs.

  13. Anatomy and function: PET-CT.

    Science.gov (United States)

    Kajander, Sami; Saraste, Antti; Ukkonen, Heikki; Knuuti, Juhani

    2010-05-01

    CT coronary angiography and perfusion PET form an attractive combination to study coronary artery lesions and their consequences in patients with coronary artery disease. Whereas CT provides non-invasive assessment of coronary lumen and wall, PET perfusion is a reliable method for the evaluation of myocardial flow. CT, although very capable of ruling out significant coronary artery disease, is less than satisfactory in assessing the actual significance of the detected lesions. PET imaging, despite its excellent sensitivity, fails to describe the exact anatomy of the epicardial vessels. By fusing image data from these two modalities, lesions can be accurately correlated with their physiological or anatomical counterparts. Hybrid PET-CT devices, now in wide clinical use, allow such fusion in a one-stop-shop study. Although still seeking its place in clinical scenarios, growing evidence suggests that hybrid PET-CT imaging of coronary anatomy and myocardial perfusion can accurately - and non-invasively - assess the existence and degree of coronary artery disease.

  14. Complicated pleural tuberculosis in children: CT evaluation

    International Nuclear Information System (INIS)

    Moon, W.K.; Kim, W.S.; Kim, I.O.; Im, J.G.; Kim, J.H.; Yeon, K.M.; Han, M.C.

    1999-01-01

    Purpose. To describe the CT features of complicated pleural tuberculosis in children and to define the use of CT in children with pleural tuberculosis. Materials and methods. The CT findings in 11 children with complicated pleural tuberculosis were retrospectively analysed. CT was performed to evaluate persistent pleural thickening (n = 6) or a mass-like lesion (n = 5) detected on plain radiographs. Chest radiographs and medical records were reviewed to determine whether additional information provided by CT had altered clinical management. Results. On CT, more than one location was involved in five patients (45 %) and in two patients (18 %) the entire pleural spaces were involved. Pleural thickening was seen in all 11 patients and enhancement after administration of contrast medium occurred in ten patients (91 %). Low-density fluid collections were seen in nine patients (82 %) and in two, CT revealed fluid collections within calcified pleural lesions. In five patients with mass-like lesions on plain radiographs, CT showed a low-density pleural mass with peripheral enhancement in four and a calcified pleural mass with fluid collection in one. CT demonstrated parenchymal abnormalities on the same side as pleural lesions in all 11 patients and hilar or mediastinal adenopathy in four. Four patients (36 %) underwent surgery because of fluid within a calcified fibrothorax (n = 3) and chest wall tuberculosis (n = 1) that were seen only on CT. Conclusions. The CT features of complicated pleural tuberculosis in children were pleural thickening, enhancement and fluid collection with associated parenchymal abnormalities and lymphadenopathy. In the evaluation of children with pleural tuberculosis, CT can be useful for demonstrating fluid within a calcified fibrothorax or chest wall involvement, which usually requires surgical intervention. (orig.)

  15. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  16. CT diagnosis of retroperitoneal gigantic liposarcoma

    International Nuclear Information System (INIS)

    Fang Wei; Zheng Zhaohua; Liao Zuyuan; Hu Yinsong

    2009-01-01

    Objective: To analyze CT manifestation of retroperitoneal gigantic liposaxcoma and to improve the image understanding. Methods: Five cases of retroperitoneal gigantic liposarcoma confirmed by surgery and pathology in our hospital were collected. Plain and enhanced CT scan were performed. Results: Of five cases, one was substantive, two was pseudocyst and two was mixed tumor. Several patterns of enhancement such as strip, floccule, irregular patchy or nodular enhancement were revealed inside the lesions on enhanced CT scan. And strip-form of high density enhancement was a typical type. Conclusion: CT examination could determine the tumor's location, size and density, together with the relationship to adjacent organizations CT scan is an important method in diagnosing retroperitoneal gigantic liposarcoma. (authors)

  17. Trapping volumetric measurement by multidetector CT in chronic obstructive pulmonary disease: Effect of CT threshold

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiaohua; Yuan, Huishu [Department of Radiology, Peking University Third Hospital, Beijing 100191 (China); Duan, Jianghui [Medical School, Peking University, Beijing 100191 (China); Du, Yipeng; Shen, Ning; He, Bei [Department of Respiration Internal Medicine, Peking University Third Hospital, Beijing 100191 (China)

    2013-08-15

    Purpose: The purpose of this study was to evaluate the effect of various computed tomography (CT) thresholds on trapping volumetric measurements by multidetector CT in chronic obstructive pulmonary disease (COPD).Methods: Twenty-three COPD patients were scanned with a 64-slice CT scanner in both the inspiratory and expiratory phase. CT thresholds of −950 Hu in inspiration and −950 to −890 Hu in expiration were used, after which trapping volumetric measurements were made using computer software. Trapping volume percentage (Vtrap%) under the different CT thresholds in the expiratory phase and below −950 Hu in the inspiratory phase was compared and correlated with lung function.Results: Mean Vtrap% was similar under −930 Hu in the expiratory phase and below −950 Hu in the inspiratory phase, being 13.18 ± 9.66 and 13.95 ± 6.72 (both lungs), respectively; this difference was not significant (P= 0.240). Vtrap% under −950 Hu in the inspiratory phase and below the −950 to −890 Hu threshold in the expiratory phase was moderately negatively correlated with the ratio of forced expiratory volume in one second to forced vital capacity and the measured value of forced expiratory volume in one second as a percentage of the predicted value.Conclusions: Trapping volumetric measurement with multidetector CT is a promising method for the quantification of COPD. It is important to know the effect of various CT thresholds on trapping volumetric measurements.

  18. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  19. CT of pleural abnormalities

    International Nuclear Information System (INIS)

    Webb, W.R.

    1995-01-01

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.)

  20. CT of pleural abnormalities

    Energy Technology Data Exchange (ETDEWEB)

    Webb, W R [California Univ., San Francisco, CA (United States). Dept. of Radiology

    1996-12-31

    Briefly discussed were CT diagnosis of pleural thickening, CT technique for examining the pleura or pleuro-pulmonary disease, diagnosis of pleural collections, diagnosis of pleural fluid abnormalities in patients with pneumonia, pleural neoplasms, malignant (diffuse) mesothelioma, metastases, local fibrous tumor of the pleura (benign mesothelioma) (21 refs.).

  1. Multiplanar CT of the spine

    International Nuclear Information System (INIS)

    Rothman, S.L.G.; Glenn, W.V. Jr.

    1986-01-01

    This is an illustrated text on computed tomography (CT) of the lumbar spine with an emphasis on the role and value of multiplanar imaging for helping determine diagnoses. The book has adequate discussion of scanning techniques for the different regions, interpretations of various abnormalities, degenerative disk disease, and different diagnoses. There is a 50-page chapter on detailed sectional anatomy of the spine and useful chapters on the postoperative spine and the planning and performing of spinal surgery with CT multiplanar reconstruction. There are comprehensive chapters on spinal tumors and trauma. The final two chapters of the book are devoted to CT image processing using digital networks and CT applications of medical computer graphics

  2. Left-right subtraction of brain CT

    International Nuclear Information System (INIS)

    Ishiguchi, Tsuneo; Sakuma, Sadayuki

    1986-01-01

    A new image-processing method to obtain a left-right subtraction image of CT was designed for the automated detection of abnormalities in brain CT. An original CT image was divided in two by a centerline. Then the right half of the image was subtracted from the left half by calculating the absorption value of the pixels on the symmetrical positions against the centerline. The mean and the standard deviation of the absorption value of the pixels in the subtraction image were used as parameters for analysis, and the detectability of abnormal CT findings was evaluated in 100 cases - 50 cases each with normal and abnormal CT. The presence of abnormalities could be diagnosed with a sensitivity of 86 %, a specificity of 90 %, and an overall accuracy of 88 % when the borderline of these parameters between normal and abnormal CT was set at the mean + 2SD in the normal group. As a further analysis, the CT image was subdivided into several areas from a functional or anatomical viewpoint, such as cerebral vascular territories, and the left-right subtraction image of each area was obtained. The possibilities of diagnosing the location of an abnormality and of detecting smaller lesions with this method were shown. Left-right subtraction was considered to be a useful method for the detection of asymmetric abnormalities in the automated diagnosis of brain CT. (author)

  3. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won [Kyung Hee University Hospital at Gangdong, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of); Park, Seong Jin [Kyung Hee University Hospital, College of Medicine, Kyung Hee University, Department of Radiology, Seoul (Korea, Republic of)

    2012-06-15

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  4. Reassessment of CT images to improve diagnostic accuracy in patients with suspected acute appendicitis and an equivocal preoperative CT interpretation

    International Nuclear Information System (INIS)

    Kim, Hyun Cheol; Yang, Dal Mo; Kim, Sang Won; Park, Seong Jin

    2012-01-01

    To identify CT features that discriminate individuals with and without acute appendicitis in patients with equivocal CT findings, and to assess whether knowledge of these findings improves diagnostic accuracy. 53 patients that underwent appendectomy with an indeterminate preoperative CT interpretation were selected and allocated to an acute appendicitis group or a non-appendicitis group. The 53 CT examinations were reviewed by two radiologists in consensus to identify CT findings that could aid in the discrimination of those with and without appendicitis. In addition, two additional radiologists were then requested to evaluate independently the 53 CT examinations using a 4-point scale, both before and after being informed of the potentially discriminating criteria. CT findings found to be significantly different in the two groups were; the presence of appendiceal wall enhancement, intraluminal air in appendix, a coexistent inflammatory lesion, and appendiceal wall thickening (P < 0.05). Areas under the curves of reviewers 1 and 2 significantly increased from 0.516 and 0.706 to 0.677 and 0.841, respectively, when reviewers were told which CT variables were significant (P = 0.0193 and P = 0.0397, respectively). Knowledge of the identified CT findings was found to improve diagnostic accuracy for acute appendicitis in patients with equivocal CT findings. circle Numerous patients with clinically equivocal appendicitis do not have acute appendicitis circle Computed tomography (CT) helps to reduce the negative appendectomy rate circle CT is not always infallible and may also demonstrate indeterminate findings circle However knowledge of significant CT variables can further reduce negative appendectomy rate circle An equivocal CT interpretation of appendicitis should be reassessed with this knowledge. (orig.)

  5. Spect-CT and PET: CT in the management of differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Khan, Shoukat H.

    2007-01-01

    Full text: With the advancement and evolution in medical technology notably imaging there has been a sea change in the overall management strategy of most of the cancers of human body. The present day functional, imaging with PET and MRI enables us to pick up a tumour at its cellular stage. Molecular imaging and nanotechnology have further added to this expanding armamentarium of cancer imaging and treatment. Thyroid cancer is one such cancer where the cutting edge biotechnology has dramatically changed the management profile of a disease. Thyroid cancer can safely be classified as one of the cancers which if optimally managed is curable. Hybrid and fusion imaging like SPECT-CT and PET-CT with their superior sensitivity and specificity have greatly improved the accuracy of disease detection and reduced drastically the false positive disease sites. Disease not detected by conventional planar imaging can now be detected and also anatomically localized using hybrid imaging modalities of SPECT-CT and PET-CT. An accurate detection and precise localization improves image interpretation and a treatment optimization in the curable cancer of thyroid

  6. Comparison of CT and integrated PET-CT based radiation therapy planning in patients with malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Pehlivan, Berrin; Topkan, Erkan; Onal, Cem; Nursal, Gul Nihal; Yuksel, Oznur; Dolek, Yemliha; Yavuz, Melek Nur; Yavuz, Ali Aydin

    2009-01-01

    When combined with adequate tumoricidal doses, accurate target volume delineation remains to be the one of the most important predictive factors for radiotherapy (RT) success in locally advanced or medically inoperable malignant pleural mesothelioma (MPM) patients. Recently, 18-fluorodeoxyglucose positron emission tomography (PET) has demonstrated significant improvements in diagnosis and accurate staging of MPM. However, role of additional PET data has not been studied in RT planning (RTP) of patients with inoperable MPM or in those who refuse surgery. Therefore, we planned to compare CT with co-registered PET-CT as the basis for delineating target volumes in these patients group. Retrospectively, the CT and co-registered PET-CT data of 13 patients with histologically proven MPM were utilized to delineate target volumes separately. For each patient, target volumes (gross tumor volume [GTV], clinical target volume [CTV], and planning target volume [PTV]) were defined using the CT and PET-CT fusion data sets. The PTV was measured in two ways: PTV1 was CTV plus a 1-cm margin, and PTV2 was GTV plus a 1-cm margin. We analyzed differences in target volumes. In 12 of 13 patients, compared to CT-based delineation, PET-CT-based delineation resulted in a statistically significant decrease in the mean GTV, CTV, PTV1, and PTV2. In these 12 patients, mean GTV decreased by 47.1% ± 28.4%, mean CTV decreased by 38.7% ± 24.7%, mean PTV1 decreased by 31.1% ± 23.1%, and mean PTV2 decreased by 40.0% ± 24.0%. In 4 of 13 patients, hilar lymph nodes were identified by PET-CT that was not identified by CT alone, changing the nodal status of tumor staging in those patients. This study demonstrated the usefulness of PET-CT-based target volume delineation in patients with MPM. Co-registration of PET and CT information reduces the likelihood of geographic misses, and additionally, significant reductions observed in target volumes may potentially allow escalation of RT dose beyond

  7. CT Diagnosis of Appendicitis

    Directory of Open Access Journals (Sweden)

    Christopher Libby

    2017-01-01

    Full Text Available History of present illness: A 19-year-old male with no previous medical history presented with 7/10 non-radiating, constant, sharp, periumbilical pain associated with nausea, and four episodes of vomiting. He was seen at urgent care where his labs showed a WBC of 16,000/mcL. He was subsequently sent to the emergency department (ED for concern of appendicitis. Of note, his pain worsened with bumps during the drive to the ED. After arriving to the ED the pain migrated to the right lower quadrant. Computed tomography (CT revealed acute appendicitis and the patient was admitted to the surgery service and taken to the operating room (OR for an appendectomy. Significant findings: The CT abdomen/pelvis with IV contrast shows a dilated appendix (see red outline with thickened, hyperenhancing wall (see blue outline best visualized in the axial and coronal planes. Discussion: Appendicitis is a common diagnosis in the emergency department in patients presenting with abdominal pain, occurring most frequently in young adults with a peak incidence in those aged 10-19.1 Failure to quickly diagnose acute appendicitis can result in perforation rates as high as 80 percent.2 While the diagnosis of appendicitis can be made clinically, CT is a non-invasive modality that improves the detection of appendicitis with sensitivities of 88–100%, specificities of 91–99%, positive predictive values of 92–98%, negative predictive values of 95–100%, and accuracies of 94–98%.3-8 The major advantage of CT over both clinical exam and ultrasound is the ability of the radiologist to exclude acute appendicitis if the appendix appears normal. However, CT carries the risks associated with ionizing radiation. While previously there was some debate on the best choice for type of CT scan and use of IV and oral contrast, recent studies have shown that CT abdomen/pelvis with IV contrast alone is sufficient for diagnosis of appendicitis.9, 10

  8. CT examinations in older patients

    International Nuclear Information System (INIS)

    Sciuk, J.; Peters, P.E.

    1989-01-01

    A total of 2,878 unselected subsequent CT examinations carried out in 1984 were analyzed retrospectively. All studies were performed in a university hospital with a centralized department of diagnostic radiology. Most of the patients investigated were hospitalized; there were only 12% outpatients. Of the patients studied 12.6% were older than 65 years and 20.5% older than 60; 17.7% were emergency cases and patients between 16 and 25 years of age represented the largest fraction. In all other age groups the relative distribution between emergency cases and regular studies revealed no significant differences. There was no statistically significant difference between the older age group (patients older than 65 years) and the total population of this study in almost all items investigated, i.e., no differences in CT examination time and no differences in preparation time (time between two CT studies). The rate of abdominal CT examinations was 7% higher in the older age group, while the relative distribution of all other CT examinations was again comparable to the total population under study. Thus, the expected increase in patients in the older age group does not measurably prolong the CT examination time. This statement applies to a major referral center with a high percentage of inpatients. (orig.) [de

  9. Overview of CT technologies for children

    Energy Technology Data Exchange (ETDEWEB)

    Frush, Donald P. [Duke University Medical Center, Department of Radiology, Box 3808, Durham, NC (United States)

    2014-10-15

    Many technical advances in CT have reduced radiation exposure in children and adults. These advances in technology should be used in conjunction with CT techniques such as appropriate patient preparation and intravenous contrast media administration to maximize dose management and image quality. This article summarizes current dose reduction technologies for pediatric CT, noting ranges of dose reduction as well as potential limitations. Discussion includes some of the elusive aspects of assessing image quality and the need for developing personalized CT. (orig.)

  10. Overview of CT technologies for children

    International Nuclear Information System (INIS)

    Frush, Donald P.

    2014-01-01

    Many technical advances in CT have reduced radiation exposure in children and adults. These advances in technology should be used in conjunction with CT techniques such as appropriate patient preparation and intravenous contrast media administration to maximize dose management and image quality. This article summarizes current dose reduction technologies for pediatric CT, noting ranges of dose reduction as well as potential limitations. Discussion includes some of the elusive aspects of assessing image quality and the need for developing personalized CT. (orig.)

  11. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, R. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology; Johansen, J.G. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology

    1995-09-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG).

  12. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    International Nuclear Information System (INIS)

    Dullerud, R.; Johansen, J.G.

    1995-01-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG)

  13. PET/CT in malignant melanoma: contrast-enhanced CT versus plain low-dose CT

    International Nuclear Information System (INIS)

    Pfluger, Thomas; Schneider, Vera; Fougere, Christian la; Bartenstein, Peter; Weiss, Mayo; Melzer, Henriette Ingrid; Coppenrath, Eva; Berking, Carola

    2011-01-01

    The aim of this study was to evaluate the diagnostic value of contrast-enhanced CT (CECT) versus non-enhanced low-dose CT (NECT) in the staging of advanced malignant melanoma with 18 F-fluordeoxyglucose (FDG) positron emission tomography (PET)/CT. In total, 50 18 F-FDG PET/CT examinations were performed in 50 patients with metastasized melanoma. For attenuation correction, whole-body NECT was performed followed by diagnostic CECT with contrast agent. For the whole-body PET, 18 F-FDG was applied. Criteria for evaluation were signs of vital tumour tissue (extent of lesions, contrast enhancement, maximum standardized uptake value >2.5). Findings suspicious for melanoma were considered lesions. NECT, CECT and 18 F-FDG PET were evaluated separately, followed by combined analysis of PET/NECT and PET/CECT. Findings were verified histologically and/or by follow-up (>6 months). Overall, 232 lesions were analysed, and 151 proved to be metastases. The sensitivity of NECT, CECT, PET, PET/NECT and PET/CECT was 62, 85, 90, 97 and 100%, and specificity was 52, 63, 88, 93 and 93%, respectively. Compared to CECT, NECT obtained additional false-negative results: lymph node (n = 19) and liver/spleen metastases (n = 9). Misinterpreted physiological structures mainly caused additional false-positive findings (n = 17). In combined analysis of PET/NECT, six false-positive [other tumours (n = 2), inflammatory lymph nodes (n = 2), inflammatory lung lesion (n = 1), blood vessel (n = 1)] and five false-negative findings [liver (n = 3), spleen (n = 1), lymph node metastases (n = 1)] remained. On PET/CECT, six false-positive [inflammatory lymph nodes (n = 3), other tumours (n = 2), inflammatory lung lesion (n = 1)] and no false-negative findings occurred. However, additional false findings on PET/NECT (6 of 232) did not change staging compared to PET/CECT. Our results indicate that it is justified to perform PET/NECT instead of PET/CECT for melanoma staging. (orig.)

  14. Diagnostic performance of contrast enhanced CT and 18F-FDG PET/CT in suspicious recurrence of biliary tract cancer after curative resection

    International Nuclear Information System (INIS)

    Lee, Yun-Gyoo; Bang, Yung-Jue; Han, Sae-Won; Oh, Do-Youn; Chie, Eui Kyu; Jang, Jin-Young; Im, Seock-Ah; Kim, Tae-You; Kim, Sun-Whe; Ha, Sung Whan

    2011-01-01

    Because of the late clinical presentation of biliary tract cancer (BTC), only 10% of patients are eligible for curative surgery. Even among those patients who have undergone curative surgery, most patients develop recurrent cancer. This study is to determine the clinical role of 18 F-FDG PET/CT during post-operative surveillance of suspected recurrent BTC based on symptoms, laboratory findings and contrast-enhanced CT (ceCT) findings. We consecutively enrolled 50 patients with BTC who underwent curative surgery. An 18 F-FDG PET/CT was obtained for assessment of recurrence based on clinical suspicion during post-operative surveillance. The final confirmation of recurrence was determined pathologically or clinically. When a pathologic confirmation was impossible or inconclusive, a clinical confirmation was used by radiologic correlation with subsequent follow-up ceCT at a minimum of 3-month intervals. Diagnostic efficacy was evaluated by comparing the results of ceCT and 18 F-FDG PET/CT with the final diagnosis. Among the 50 patients, 34(68%) were confirmed to have a recurrence. PET/CT showed higher sensitivity (88% vs. 76%, p = 0.16) and accuracy (82% vs. 66%, p = 0.11) for recurrence compared to ceCT, even though the difference was not significant. The positive (86% vs. 74%, p = 0.72) and negative predictive values for recurrence (73% vs. 47%, p = 0.55) were not significantly different between PET/CT and ceCT. However, an additional PET/CT on ceCT significantly improved the sensitivity than did a ceCT alone (94% [32/34] for PET/CT on ceCT vs. 76% [26/34] for ceCT alone, p = 0.03) without increasing the specificity, positive predictive value, and negative predictive value. 18 F-FDG PET/CT alone is not more sensitive or specific than ceCT in the detection of recurrent BTC after curative surgery. These results do not reach statistical significance, probably due to the low number of patients. However, an additional 18 F-FDG PET/CT on ceCT significantly improves the

  15. Predicting tumor hypoxia in non-small cell lung cancer by combining CT, FDG PET and dynamic contrast-enhanced CT.

    Science.gov (United States)

    Even, Aniek J G; Reymen, Bart; La Fontaine, Matthew D; Das, Marco; Jochems, Arthur; Mottaghy, Felix M; Belderbos, José S A; De Ruysscher, Dirk; Lambin, Philippe; van Elmpt, Wouter

    2017-11-01

    Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUV mean ) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm 3 ) by the best performing model. We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The

  16. Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring

    OpenAIRE

    Song, Inyoung; Yi, Jeong Geun; Park, Jeong Hee; Kim, Sung Mok; Lee, Kyung Soo; Chung, Myung Jin

    2016-01-01

    Objective To evaluate the feasibility of coronary artery calcium scoring based on three virtual noncontrast-enhanced (VNC) images derived from single-source spectral dual-energy CT (DECT) as compared with true noncontrast-enhanced (TNC) images. Materials and Methods This prospective study was conducted with the approval of our Institutional Review Board. Ninety-seven patients underwent noncontrast CT followed by contrast-enhanced chest CT using single-source spectral DECT. Iodine eliminated V...

  17. CT applications of medical computer graphics

    International Nuclear Information System (INIS)

    Rhodes, M.L.

    1985-01-01

    Few applications of computer graphics show as much promise and early success as that for CT. Unlike electron microscopy, ultrasound, business, military, and animation applications, CT image data are inherently digital. CT pictures can be processed directly by programs well established in the fields of computer graphics and digital image processing. Methods for reformatting digital pictures, enhancing structure shape, reducing image noise, and rendering three-dimensional (3D) scenes of anatomic structures have all become routine at many CT centers. In this chapter, the authors provide a brief introduction to computer graphics terms and techniques commonly applied to CT pictures and, when appropriate, to those showing promise for magnetic resonance images. Topics discussed here are image-processing options that are applied to digital images already constructed. In the final portion of this chapter techniques for ''slicing'' CT image data are presented, and geometric principles that describe the specification of oblique and curved images are outlined. Clinical examples are included

  18. CT images of infantile viral encephalitis

    International Nuclear Information System (INIS)

    Sugimoto, Tateo; Okazaki, Hitoshi; Woo, Man

    1985-01-01

    Cranial CT scanning was undertaken in 40 patients with infantile viral encephalitis seen from 1977 to 1983. According to the pathogenic viruses, abnormal CT findings were detected most frequently in cases of herpes simplex encephalitis (HSE), followed by non-eruptive viral encephalitis, measles encephalitis, and rubella encephalitis in that order, which coincided well with neurological prognosis. Although CT findings lay within a normal range in cases of measles encephalitis, except a case in which cerebral ventricle was slightly dilated, the degree of consciousness disturbance was unfavorable and it persisted long. This revealed that there is no distinct correlation between the degree of consciousness disturbance and CT findings. Normal CT findings were detected in 13% of patients aged less than 5 years and 76.5% of patients aged 5 years or more. In many patients who had an attack of viral encephalitis at the age of 5 years or more, epileptic seizures occurred frequently, even though CT findings were normal. (Namekawa, K.)

  19. MR and CT for malignant hypernephromas

    International Nuclear Information System (INIS)

    Uhlenbrock, D.; Fischer, C.; Ruehl, G.; Beyer, H.K.; Hummelsheim, P.; Bochum Univ.; Marienhospital, Herne; Bochum Univ.

    1987-01-01

    Forty patients with histologically confirmed hypernephromas were examined by MR and CT. As regards T-staging, MR had an accuracy of 97 % and CT of 91%; for N-staging, MR had an accuracy of 85% and CT of 91% and, with regard to infiltration of the renal vein, MR was correct in 88% of cases and CT in 81%. MR was most accurate in the pre-operative assessment of tumour spread, demonstrating caval involvement in 100% and lymph node metastases in 97%. On the other hand, infiltration of the renal pelvis could be assessed in only 65% of cases; in 27% the assessment was not possible and in 8% one could not be certain. CT proved to be at its best for staging of lymph nodes, but in 15% it was not possible to identify infiltration of the renal vein. MR was not greatly superior to CT in the preoperative diagnosis and staging of hypernephromas. (orig.) [de

  20. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    International Nuclear Information System (INIS)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T.; O'Brien, Maureen M.

    2018-01-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  1. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); O' Brien, Maureen M. [Cincinnati Children' s Hospital Medical Center, Division of Oncology, Cancer and Blood Disease Institute, Cincinnati, OH (United States)

    2018-02-15

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  2. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  3. Panoramic three-dimensional CT imaging

    International Nuclear Information System (INIS)

    Kawamata, Akitoshi; Fujishita, Masami

    1998-01-01

    Panoramic radiography is a unique projection technique for producing a single image of both maxillary and mandibular arches and many other anatomical structures. To obtain a similar panoramic image without panoramic radiography system, a modified three-dimensional (3D) CT imaging technique was designed. A set of CT slice image data extending from the chin to the orbit was used for 3D reconstruction. The CT machine used in this study was the X-Vision (TOSHIBA, Japan). The helical scan technique was used. The slice thickness of reconstructed image was one or 1.5 mm. The occlusal plane or Frankfort horizontal (FH) plane was used as the reference line. The resultant slice image data was stored on a magnetic optical disk and then used to create panoramic 3D-CT images on a Macintosh computer systems (Power Macintosh 8600/250, Apple Computer Inc., USA). To create the panoramic 3D-CT image, the following procedure was designed: Design a curved panoramic 3D-CT imaging layer using the imaging layer and the movement of the x-ray beam in panoramic radiography system as a template; Cut this imaging layer from each slice image, then the trimmed image was transformed to a rectangular layer using the ''still image warping'' special effect in the Elastic Reality special effects system (Elastic Reality Inc., USA); Create panoramic 3D-CT image using the Voxel View (Vital Images Inc., USA) rendering system and volume rendering technique. Although the image quality was primitive, a panoramic view of maxillofacial region was obtained by this technique. (author)

  4. Use of the CT component of PET-CT to improve PET-MR registration: demonstration in soft-tissue sarcoma

    International Nuclear Information System (INIS)

    Somer, Edward J; Benatar, Nigel A; O'Doherty, Michael J; Smith, Mike A; Marsden, Paul K

    2007-01-01

    We have investigated improvements to PET-MR image registration offered by PET-CT scanning. Ten subjects with suspected soft-tissue sarcomas were scanned with an in-line PET-CT and a clinical MR scanner. PET to CT, CT to MR and PET to MR image registrations were performed using a rigid-body external marker technique and rigid and non-rigid voxel-similarity algorithms. PET-MR registration was also performed using transformations derived from the registration of CT to MR. The external marker technique gave fiducial registration errors of 2.1 mm, 5.1 mm and 5.3 mm for PET-CT, PET-MR and CT-MR registration. Target registration errors were 3.9 mm, 9.0 mm and 9.3 mm, respectively. Voxel-based algorithms were evaluated by measuring the distance between corresponding fiducials after registration. Registration errors of 6.4 mm, 14.5 mm and 9.5 mm, respectively, for PET-CT, PET-MR and CT-MR were observed for rigid-body registration while non-rigid registration gave errors of 6.8 mm, 16.3 mm and 7.6 mm for the same modality combinations. The application of rigid and non-rigid CT to MR transformations to accompanying PET data gives significantly reduced PET-MR errors of 10.0 mm and 8.5 mm, respectively. Visual comparison by two independent observers confirmed the improvement over direct PET-MR registration. We conclude that PET-MR registration can be more accurately and reliably achieved using the hybrid technique described than through direct rigid-body registration of PET to MR

  5. Chest CT in children: anesthesia and atelectasis

    Energy Technology Data Exchange (ETDEWEB)

    Newman, Beverley; Gawande, Rakhee [Lucile Packard Children' s Hospital, Department of Radiology, Stanford, CA (United States); Krane, Elliot J. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Anesthesiology, Perioperative and Pain Medicine, Stanford, CA (United States); Holmes, Tyson H. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Psychiatry and Behavioral Sciences, Stanford, CA (United States); Robinson, Terry E. [Stanford University School of Medicine, Lucile Packard Children' s Hospital, Department of Pulmonary Medicine and Cystic Fibrosis Center for Excellence in Pulmonary Biology, Stanford, CA (United States)

    2014-02-15

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  6. Chest CT in children: anesthesia and atelectasis

    International Nuclear Information System (INIS)

    Newman, Beverley; Gawande, Rakhee; Krane, Elliot J.; Holmes, Tyson H.; Robinson, Terry E.

    2014-01-01

    There has been an increasing tendency for anesthesiologists to be responsible for providing sedation or anesthesia during chest CT imaging in young children. Anesthesia-related atelectasis noted on chest CT imaging has proven to be a common and troublesome problem, affecting image quality and diagnostic sensitivity. To evaluate the safety and effectiveness of a standardized anesthesia, lung recruitment, controlled-ventilation technique developed at our institution to prevent atelectasis for chest CT imaging in young children. Fifty-six chest CT scans were obtained in 42 children using a research-based intubation, lung recruitment and controlled-ventilation CT scanning protocol. These studies were compared with 70 non-protocolized chest CT scans under anesthesia taken from 18 of the same children, who were tested at different times, without the specific lung recruitment and controlled-ventilation technique. Two radiology readers scored all inspiratory chest CT scans for overall CT quality and atelectasis. Detailed cardiorespiratory parameters were evaluated at baseline, and during recruitment and inspiratory imaging on 21 controlled-ventilation cases and 8 control cases. Significant differences were noted between groups for both quality and atelectasis scores with optimal scoring demonstrated in the controlled-ventilation cases where 70% were rated very good to excellent quality scans compared with only 24% of non-protocol cases. There was no or minimal atelectasis in 48% of the controlled ventilation cases compared to 51% of non-protocol cases with segmental, multisegmental or lobar atelectasis present. No significant difference in cardiorespiratory parameters was found between controlled ventilation and other chest CT cases and no procedure-related adverse events occurred. Controlled-ventilation infant CT scanning under general anesthesia, utilizing intubation and recruitment maneuvers followed by chest CT scans, appears to be a safe and effective method to obtain

  7. Sacral-neuromodulation CT-guided

    International Nuclear Information System (INIS)

    Amoroso, Lamberto; Ricci, Stefano; Pelliccioni, Giuseppe; Scarpino, Osvaldo; Ghiselli, Roberto; Saba, Vittorio

    2005-01-01

    Purpose: Sacral neuromodulation is a new treatment for refractory voiding disorders such as urge incontinence, urinary retention, frequency-urgency syndromes and faecal incontinence. The current approach to sacral nerve stimulation consists of a two-stage procedure. The first is a PNE test (Percutaneous Nerve Evaluation) by a provisional electrically stimulated spinal needle, placed percutaneously in the S3 foramina for four of ten days. If successful, the second stage, permanent implantation, is carried out. The PNE test is performed under fluoroscopic control using the palpable bony sacral foramina as referral points. This technique can show some limitations, such as operator Rx exposure, poor visualization of sacral foramina because of bowel gas artefacts or sacral malformation. In order to reduce these inconveniences and to improve efficiency of the test we tried an alternative technique. The purpose of our study was to test the use of CT as an alternative technique in order to evaluate its advantages and possible routine use. Materials and methods: We tested 30 patients with the PNE test under CT guidance (16 males and 14 females) suffering from serious pelvic disorders and not responding to the normal therapeutic regime. Twenty-seven patient showed relative anatomical integrity of the pelvis and the sacrum, the remaining 3 patients presented morphological anormalities of the sacral foramina. With the patient in the prone position the sacral foramina were identified with CT volumetric scanning using a spiral CT scanner equipped with a second console for the three-dimensional reconstructions. Having identified the location of the S3 foramina, a sterile field was prepared and the spiral needle introduced checking correct positioning with a CT control scan. An electrode was inserted after having checked correct muscular contractile response and the precise position with a further CT scan. Results: Thirty patients were subjected to PNE under CT guidance for a

  8. CT numbers of liver and spleen in normal children

    International Nuclear Information System (INIS)

    Kim, Young Kim

    2002-01-01

    To determine the mean liver CT numbers, and differences between liver and spleen, and liver and back muscle CT numbers in normal children, and to correlate the findings with sex and age. One hundred and five normal children aged 2-14 years underwent pre-contrast CT scanning. Mean CT numbers of the liver, spleen, and back muscles were calculated, as well as the differences in CT numbers between the liver and spleen (liver-spleen CT numbers), and between the liver-back muscle CT numbers were 70.22±6.51 HU, 53.28±3.57 HU, 17.13±6.57 HU, and 11.88±5.94 HU, respectively. Mean liver CT numbers and the difference between liver and back muscle CT numbers were not different by age. By sex, all the CT numbers did not vary according to age. The sex of a subject did not affect the CT number. The children's mean liver CT number was 70.22±6.51 HU and the difference between liver and spleen CT numbers was 17.13±6.57 HU. Younger children had higher liver CT and liver-spleen CT numbers than older children. No CT numbers varied according to sex

  9. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  10. Variation in the quality of CT images of the upper abdomen when CT automatic exposure control is employed

    International Nuclear Information System (INIS)

    Aizawa, Isao; Muramatsu, Yoshihisa; Nomura, Keiichi; Shimizu, Fuminori

    2010-01-01

    The aim of this study was to analyze the reason for variation of image quality in the upper abdomen CT with the use of CT-automatic exposure control (AEC). The CT investigated was 3D modulation in the 16 multi detector row CT (MDCT) and lung cancer screening CT (LSCT) phantom was used to simulate the patient. When there was a phase difference, an image noise increase of around 15% at the maximum was accepted. It is concluded that the major reason for variation in image quality is respiratory motion and the importance of respiration control must be recognized. (author)

  11. Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging

    International Nuclear Information System (INIS)

    Aschoff, Philip; Plathow, Christian; Lichy, Matthias P.; Claussen, Claus D.; Pfannenberg, Christina; Beyer, Thomas; Erb, Gunter; Oeksuez, Mehmet Oe.

    2012-01-01

    State-of-the-art positron emission tomography/computed tomography (PET/CT) systems incorporate multislice CT technology, thus facilitating the acquisition of multiphase, contrast-enhanced CT data as part of integrated PET/CT imaging protocols. We assess the influence of a highly concentrated iodinated contrast medium (CM) on quantification and image quality following CT-based attenuation correction (CT-AC) in PET/CT. Twenty-eight patients with suspected malignant liver lesions were enrolled prospectively. PET/CT was performed 60 min after injection of 400 MBq of 18 F-fluorodeoxyglucose (FDG) and following the biphasic administration of an intravenous CM (400 mg iodine/ml, Iomeron 400). PET images were reconstructed with CT-AC using any of four acquired CT image sets: non-enhanced, pre-contrast (n-PET), arterial phase (art-PET), portal venous phase (pv-PET) and late phase (late-PET). Normal tissue activity and liver lesions were assessed visually and quantitatively on each PET/CT image set. Visual assessment of PET following CT-AC revealed no noticeable difference in image appearance or quality when using any of the four CT data sets for CT-AC. A total of 44 PET-positive liver lesions was identified in 21 of 28 patients. There were no false-negative or false-positive lesions on PET. Mean standardized uptake values (SUV) in 36 evaluable lesions were: 5.5 (n-PET), 5.8 (art-PET), 5.8 (pv-PET) and 5.8 (late-PET), with the highest mean increase in mean SUV of 6%. Mean SUV changes in liver background increased by up to 10% from n-PET to pv-PET. Multiphase CT data acquired with the use of highly concentrated CM can be used for qualitative assessment of liver lesions in torso FDG PET/CT. The influence on quantification of FDG uptake is small and negligible for most clinical applications. (orig.)

  12. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT.

    Science.gov (United States)

    Chami, H A; Faraj, W; Yehia, Z A; Badour, S A; Sawan, P; Rebeiz, K; Safa, R; Saade, C; Ghandour, B; Shamseddine, A; Mukherji, D; Haydar, A A

    2015-12-01

    To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below -950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01-1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. CT of chest trauma

    International Nuclear Information System (INIS)

    Goodman, P.C.

    1986-01-01

    There appears to be a limited role for computed tomography in the evaluation of chest trauma. The literature contains few papers specifically addressing the use of CT in the setting of chest trauma. Another series of articles relates anecdotal experiences in this regard. This paucity of reports attests to the remarkable amount of information present on conventional chest radiographs as well as the lack of clear indications for CT in the setting of chest trauma. In this chapter traumatic lesions of various areas of the thorax are discussed. The conventional radiographic findings are briefly described and the potential or proven application of CT is addressed

  14. CT pelvimetry. La scanopelvimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J. (Hopital d' Instruction des Armees Begin, 94 - Saint-Mande (FR))

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique.

  15. PET/CT: underlying physics, instrumentation, and advances.

    Science.gov (United States)

    Torres Espallardo, I

    Since it was first introduced, the main goal of PET/CT has been to provide both PET and CT images with high clinical quality and to present them to radiologists and specialists in nuclear medicine as a fused, perfectly aligned image. The use of fused PET and CT images quickly became routine in clinical practice, showing the great potential of these hybrid scanners. Thanks to this success, manufacturers have gone beyond considering CT as a mere attenuation corrector for PET, concentrating instead on design high performance PET and CT scanners with more interesting features. Since the first commercial PET/CT scanner became available in 2001, both the PET component and the CT component have improved immensely. In the case of PET, faster scintillation crystals with high stopping power such as LYSO crystals have enabled more sensitive devices to be built, making it possible to reduce the number of undesired coincidence events and to use time of flight (TOF) techniques. All these advances have improved lesion detection, especially in situations with very noisy backgrounds. Iterative reconstruction methods, together with the corrections carried out during the reconstruction and the use of the point-spread function, have improved image quality. In parallel, CT instrumentation has also improved significantly, and 64- and 128-row detectors have been incorporated into the most modern PET/CT scanners. This makes it possible to obtain high quality diagnostic anatomic images in a few seconds that both enable the correction of PET attenuation and provide information for diagnosis. Furthermore, nowadays nearly all PET/CT scanners have a system that modulates the dose of radiation that the patient is exposed to in the CT study in function of the region scanned. This article reviews the underlying physics of PET and CT imaging separately, describes the changes in the instrumentation and standard protocols in a combined PET/CT system, and finally points out the most important

  16. Usefulness and limit of CT diagnosis on appendicitis

    International Nuclear Information System (INIS)

    Kuchiki, Megumi; Takanashi, Toshiyasu; Yamaguchi, Koichi.

    1997-01-01

    CT was performed in 104 patients with abdominal pain suspected appendicitis. CT showed positive finding (abnormal appendix, appendicolith, pericecal inflammatory change, fluid collection, LN swelling, abscess) and complication of appendicitis clearly. CT diagnosis showed high accuracy than clinical diagnosis. CT proved its usefulness especially only CT imaging showed the correct diagnosis. On the other hand, diverticulitis and terminal ileitis common diagnostic disease of appendicitis showed similar clinical appearance and CT image, caused to be difficult to diagnose correctly. In the cases showing similar image to appendicitis or atypical image, CT also proved its limit of the diagnosis on appendicitis. (author)

  17. Pediatric CT quality management and improvement program

    International Nuclear Information System (INIS)

    Larson, David B.; Chan, Frandics P.; Newman, Beverley; Fleischmann, Dominik; Molvin, Lior Z.; Wang, Jia

    2014-01-01

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve. (orig.)

  18. Pediatric CT quality management and improvement program

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B.; Chan, Frandics P.; Newman, Beverley; Fleischmann, Dominik [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States); Molvin, Lior Z. [Stanford Hospital and Clinics, Stanford, CA (United States); Wang, Jia [Stanford University, Environmental Health and Safety, Stanford, CA (United States)

    2014-10-15

    Modern CT is a powerful yet increasingly complex technology that continues to rapidly evolve; optimal clinical implementation as well as appropriate quality management and improvement in CT are challenging but attainable. This article outlines the organizational structure on which a CT quality management and improvement program can be built, followed by a discussion of common as well as pediatric-specific challenges. Organizational elements of a CT quality management and improvement program include the formulation of clear objectives; definition of the roles and responsibilities of key personnel; implementation of a technologist training, coaching and feedback program; and use of an efficient and accurate monitoring system. Key personnel and roles include a radiologist as the CT director, a qualified CT medical physicist, as well as technologists with specific responsibilities and adequate time dedicated to operation management, CT protocol management and CT technologist education. Common challenges in managing a clinical CT operation are related to the complexity of newly introduced technology, of training and communication and of performance monitoring. Challenges specific to pediatric patients include the importance of including patient size in protocol and dose considerations, a lower tolerance for error in these patients, and a smaller sample size from which to learn and improve. (orig.)

  19. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  20. Development of a guideline on reading CT images of malignant pleural mesothelioma and selection of the reference CT films

    International Nuclear Information System (INIS)

    Zhou, Huashi; Tamura, Taro; Kusaka, Yukinori; Suganuma, Narufumi; Subhannachart, Ponglada; Vijitsanguan, Chomphunut; Noisiri, Weeraya; Hering, Kurt G.; Akira, Masanori; Itoh, Harumi

    2012-01-01

    Purpose: International experts developed a guideline on reading CT images of malignant pleural mesothelioma for radiologists and physicians. It is intended that it act as a supplement to the current International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Methods: The research literatures on mesothelioma CT features were systematically reviewed. Ten mesothelioma CT features were adopted into the guideline prepared according to experts’ opinion. The terminology of mesothelioma CT features and mesothelioma probability were agreed by consensus of experts. The CT reference films for each mesothelioma feature were selected based on agreement by experts from 22 definite mesothelioma cases confirmed pathologically and immunohistochemically. To support the validity of the mesothelioma probability, 4 experts’ readings of CT films from 57 cases with or without mesothelioma were analyzed by kappa statistics between the experts; sensitivity and specificity for mesothelioma were also assessed. Results: The mesothelioma CT Guideline was developed, providing the terminology of CT features and the mesothelioma probability, the judgement of severity, the distribution of mesothelioma, and the revised CT reading sheet including mesothelioma items. The CT reference films with ten mesothelioma typical features were selected. The average linearly and quadratically weighted kappa of the agreement on the 4-point scale mesothelioma probability were 0.58 and 0.71, respectively. The average sensitivity and specificity for mesothelioma were 93.2% and 65.6%, respectively. Conclusion: The evidence-based mesothelioma CT Guideline developed may serve as a good educational tool to facilitate physicians in recognising mesothelioma and improve their proficiency in diagnosis of mesothelioma.

  1. Development of a guideline on reading CT images of malignant pleural mesothelioma and selection of the reference CT films

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Huashi, E-mail: zhouhua@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Tamura, Taro, E-mail: tarou@u-fukui.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Kusaka, Yukinori, E-mail: kusakayk@gmail.com [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Suganuma, Narufumi, E-mail: nsuganuma@kochi-u.ac.jp [Department of Environmental Medicine, Kochi University School of Medicine (Japan); Subhannachart, Ponglada, E-mail: pongladas@gmail.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Vijitsanguan, Chomphunut, E-mail: Chompoo_vj@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Noisiri, Weeraya, E-mail: weeraya_tat@yahoo.com [Central Chest Disease Institute of Thailand, 39 Moo 9, Tiwanon Road, Muang Nonthaburi 11000 (Thailand); Hering, Kurt G., E-mail: k.g.hering@t-online.de [Department of Diagnostic Radiology, Radiooncology and Nuclear Medicine, Radiological Clinic, Miner' s Hospital, Radiologische Klinik, Lansppaschaftskranhaus Dortmund, Wieckesweg 27 44309, Dortmund (Germany); Akira, Masanori, E-mail: akira@kch.hosp.go.jp [Department of Radiology, National Hospital Organization Kinki-Chuo Chest Medical Center, 1180 Nagasone-cho, Kita-ku, Sakai, Osaka 591-8555 (Japan); Itoh, Harumi, E-mail: hitoh@fmsrsa.fukui-med.ac.jp [Department of Environmental Health, School of Medicine, University of Fukui, 23-3 Shimoaitsuki, Matsuoka, Eihezi-cho, Fukui Prefecture 910-1193 (Japan); Department of Radiology, School of Medicine, University of Fukui, 23-3 Shimoaitsuki Matsuoka, Eiheizi-cho, Fukui Prefecture 910-1193 (Japan); and others

    2012-12-15

    Purpose: International experts developed a guideline on reading CT images of malignant pleural mesothelioma for radiologists and physicians. It is intended that it act as a supplement to the current International Classification of HRCT for Occupational and Environmental Respiratory Diseases. Methods: The research literatures on mesothelioma CT features were systematically reviewed. Ten mesothelioma CT features were adopted into the guideline prepared according to experts’ opinion. The terminology of mesothelioma CT features and mesothelioma probability were agreed by consensus of experts. The CT reference films for each mesothelioma feature were selected based on agreement by experts from 22 definite mesothelioma cases confirmed pathologically and immunohistochemically. To support the validity of the mesothelioma probability, 4 experts’ readings of CT films from 57 cases with or without mesothelioma were analyzed by kappa statistics between the experts; sensitivity and specificity for mesothelioma were also assessed. Results: The mesothelioma CT Guideline was developed, providing the terminology of CT features and the mesothelioma probability, the judgement of severity, the distribution of mesothelioma, and the revised CT reading sheet including mesothelioma items. The CT reference films with ten mesothelioma typical features were selected. The average linearly and quadratically weighted kappa of the agreement on the 4-point scale mesothelioma probability were 0.58 and 0.71, respectively. The average sensitivity and specificity for mesothelioma were 93.2% and 65.6%, respectively. Conclusion: The evidence-based mesothelioma CT Guideline developed may serve as a good educational tool to facilitate physicians in recognising mesothelioma and improve their proficiency in diagnosis of mesothelioma.

  2. CT of the neonatal head

    International Nuclear Information System (INIS)

    Mohan, S.; Rogan, E.A.; Batty, R.; Raghavan, A.; Whitby, E.H.; Hart, A.R.; Connolly, D.J.A.

    2013-01-01

    Computed tomography (CT) is used less often than other techniques on neonatal units. However, in the acute setting, CT can be invaluable in diagnosing or excluding potentially life-threatening conditions and guiding initial management in neonates. Common indications for scanning include trauma, suspected non-accidental injury, infection, or an acute hypoxic or metabolic event. The aim of this review is to provide an overview of the normal neonatal head at CT and compare this to the common pathological abnormalities. Several key features of each condition will be highlighted. It is important to note that some pathological conditions can have overlapping features at CT and, therefore, the clinical history and additional investigations are also of key importance in determining the diagnosis

  3. Helical CT of ureteral disease

    International Nuclear Information System (INIS)

    Cikman, Pablo; Bengio, Ruben; Bulacio, Javier; Zirulnik, Esteban; Garimaldi, Jorge

    2000-01-01

    Among the new applications of helical CT is the study of the ureteral pathology. The objective of this paper was to evaluate patients with suspected pathology of this organ and the repercussion in the therapeutic plans. We studied 23 patients with a helical CT protocol, without IV contrast injection and performed multiplanar reconstruction (MPR). We called this procedure Pielo CT. Thirteen ureteral stones were detected, 6 calculi, 2 urinary tract tumors, dilatation of the system in a patient with neo-bladder. In 2 patients, in whom ureteral pathology was ruled out, we found other alterations that explained the symptoms, (gallbladder stones, disk protrusion). The Pielo CT let decide a therapeutical approach in 20 or 21 patients with ureteral pathology. (author)

  4. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  5. Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tonkopi, E; Ross, AA [Department of Diagnostic Imaging, Queen Elizabeth II Health Sciences Centre, CDHA (Canada); Department of Radiology, Dalhousie University (Canada)

    2014-08-15

    Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

  6. CT finding of emphysematous gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Sang Won; Juhn, Jae Ryang; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan [Inje Medical College Paik HospitalYonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Emphysematous gastritis is a rare entity of infectious gastritis caused by gas-forming organisms and only 32 cases have been reported. CT is helpful in the diagnosis particularly in mild cases that there is only a small amount of gas. Typical CT findings of emphysematous gastritis are gas bubbles within the irregular thickened gastric wall and dilated stomach filled with secretions, debris and a large amount of gas. We report a case that was diagnosed by CT and operation.

  7. CT finding of emphysematous gastritis

    International Nuclear Information System (INIS)

    Ahn, Sang Won; Juhn, Jae Ryang; Cha, Seong Sook; Eun, Tchoong Kie; Chung, Duck Hwan

    1988-01-01

    Emphysematous gastritis is a rare entity of infectious gastritis caused by gas-forming organisms and only 32 cases have been reported. CT is helpful in the diagnosis particularly in mild cases that there is only a small amount of gas. Typical CT findings of emphysematous gastritis are gas bubbles within the irregular thickened gastric wall and dilated stomach filled with secretions, debris and a large amount of gas. We report a case that was diagnosed by CT and operation.

  8. Predictors of pneumothorax after CT-guided transthoracic needle lung biopsy: the role of quantitative CT

    International Nuclear Information System (INIS)

    Chami, H.A.; Faraj, W.; Yehia, Z.A.; Badour, S.A.; Sawan, P.; Rebeiz, K.; Safa, R.; Saade, C.; Ghandour, B.; Shamseddine, A.; Mukherji, D.; Haydar, A.A.

    2015-01-01

    Aim: To evaluate the association of quantitative computed tomography (CT) measures of emphysema with the occurrence of pneumothorax after CT-guided needle lung biopsy (NLB) accounting for other risk factors. Materials and methods: One hundred and sixty-three CT-guided NLBs performed between 2008 and 2013 with available complete chest CT within 30 days were reviewed for the occurrence of post-procedure pneumothorax. Percent emphysema was determined quantitatively as the percentage of lung voxels below −950 HU on chest CT images using automated software. Multivariable regression was used to assess the association of percent emphysema volume with the occurrence of post-procedure pneumothorax. The association of percent emphysema volume with the pneumothorax size and need for chest tube placement after NLB was also explored. Results: Percent emphysema was significantly associated with the incidence of post-NLB pneumothorax (OR=1.10 95% confidence interval: 1.01–1.15; p=0.03) adjusting for lower-lobe lesion location, needle path length, lesion size, number of passes, and pleural needle trajectory angle. Percent emphysema was not associated with the size of the pneumothorax, nor the need for chest tube placement after NLB. Conclusion: Percent emphysema determined quantitatively from chest CT is a significant predictor of post-NLB pneumothorax. - Highlights: • Examine the association between quantitative emphysema measures & post NLB pneumothorax. • The risk of post-NLB pneumothorax increases with every unit increase in percent emphysema. • Percent emphysema is a significant predictor of pneumothorax post transthoracic NLB. • Quantitative analysis of chest CT offers clinicians' objective measures to assess pneumothorax risk.

  9. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  10. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CTCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  11. Low-dose computed tomography scans with automatic exposure control for patients of different ages undergoing cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    Yang, Ching-Ching; Yang, Bang-Hung; Tu, Chun-Yuan; Wu, Tung-Hsin; Liu, Shu-Hsin

    2017-06-01

    This study aimed to evaluate the efficacy of automatic exposure control (AEC) in order to optimize low-dose computed tomography (CT) protocols for patients of different ages undergoing cardiac PET/CT and single-photon emission computed tomography/computed tomography (SPECT/CT). One PET/CT and one SPECT/CT were used to acquire CT images for four anthropomorphic phantoms representative of 1-year-old, 5-year-old and 10-year-old children and an adult. For the hybrid systems investigated in this study, the radiation dose and image quality of cardiac CT scans performed with AEC activated depend mainly on the selection of a predefined image quality index. Multiple linear regression methods were used to analyse image data from anthropomorphic phantom studies to investigate the effects of body size and predefined image quality index on CT radiation dose in cardiac PET/CT and SPECT/CT scans. The regression relationships have a coefficient of determination larger than 0.9, indicating a good fit to the data. According to the regression models, low-dose protocols using the AEC technique were optimized for patients of different ages. In comparison with the standard protocol with AEC activated for adult cardiac examinations used in our clinical routine practice, the optimized paediatric protocols in PET/CT allow 32.2, 63.7 and 79.2% CT dose reductions for anthropomorphic phantoms simulating 10-year-old, 5-year-old and 1-year-old children, respectively. The corresponding results for cardiac SPECT/CT are 8.4, 51.5 and 72.7%. AEC is a practical way to reduce CT radiation dose in cardiac PET/CT and SPECT/CT, but the AEC settings should be determined properly for optimal effect. Our results show that AEC does not eliminate the need for paediatric protocols and CT examinations using the AEC technique should be optimized for paediatric patients to reduce the radiation dose as low as reasonably achievable.

  12. Performance of integrated FDG-PET/contrast-enhanced CT in the staging and restaging of colorectal cancer: Comparison with PET and enhanced CT

    International Nuclear Information System (INIS)

    Dirisamer, Albert; Halpern, Benjamin S.; Floery, Daniel; Wolf, Florian; Beheshti, Mohsen; Mayerhoefer, Marius E.; Langsteger, Werner

    2010-01-01

    Objective: The purpose of this study was to assess the diagnostic value of PET/CT as a one step examination in patients with colorectal cancer. Therefore we proved whether diagnostic PET/CT adds information over PET or contrast-enhanced CT alone for staging or restaging of patients with colorectal cancer. Methods: Seventy-three patients (46 males and 27 females; age range: 50-81 years; mean age: 67 years) with known colorectal cancer underwent 18F-FDG-PET/CT for staging or restaging. Results: Of the 73 patients 26 patients underwent PET/CT for staging and 47 for restaging. 266 metastases could be detected in 60 patients. Contrast-enhanced PET/CT had a lesion-based sensitivity of 100%, contrast-enhanced CT of 91% and PET of 85%. PET/CT identified 2 lesions as false positive. PET/CT could also reach a patient-based sensitivity of 100%, which was superior to contrast-enhanced CT and PET. Conclusion: Our study clearly demonstrated the added value of contrast-enhanced PET/CT in staging and restaging patients with colorectal cancer over CT and PET alone.

  13. Value of PET/CT versus PET and CT performed as separate investigations in patients with Hodgkin's disease and non-Hodgkin's lymphoma

    International Nuclear Information System (INIS)

    Fougere, Christian la; Broeckel, Nicole; Pfluger, Thomas; Haug, Alexander; Scher, Bernhard; Hacker, Marcus; Hahn, Klaus; Tiling, Reinhold; Hundt, Walter; Reiser, Maximilan

    2006-01-01

    The aim of this study was to assess the clinical benefit of combined [ 18 F]FDG PET/CT in patients with malignant lymphoma as compared to separately performed PET and CT. Overall, 100 patients with Hodgkin's disease (HD) or non-Hodgkin's lymphoma (NHL) were included in this study. Co-registered PET/CT with [ 18 F]FDG and contrast medium was performed in 50 consecutive patients with NHL (n=38) or HD (n=12) for initial staging (IS) (n=12) or re-treatment staging (RS) (n=38). Another 50 patients with NHL (n=32) or HD (n=18) underwent separate PET and CT investigations within a time frame of 10 days for IS (n=22) or RS (n=28). Lymphoma involvement was separately evaluated for seven different regions in each patient. Each patient had clinical follow-up evaluation for >6 months. PET and CT data were analysed separately as well as side-by-side or in fused mode. In the PET/CT group, region-based evaluation for lymphoma involvement suggested a sensitivity/specificity of 85%/91% for CT, 98%/99% for PET and 98%/99% for PET/CT. In the PET and CT group, region-based evaluation showed a sensitivity/specificity of 87%/80% for CT, 98%/99% for PET and 98%/100% for PET and CT read side by side. PET was superior to CT alone and was improved further by side-by-side reading of both examinations. However, no significant difference was observed between PET/CT and separate PET and CT imaging in patients with lymphoma. (orig.)

  14. Radiation doses in head CT examinations in Serbia: comparison among different CT units

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Bozovic, P.; Stankovic, J.; Hadnadjev, D.; Stojanovic, S.

    2012-01-01

    A rapid increase in number of Computed Tomography (CT) examinations has been observed world wide. As haed CT is the most frequent CT examination, the purpose of this study was to collect and analyse patient doses in children and adults in different CT units for this procedure. The study included 8 CT units from three manufacturers (Siemens, Toshiba and General Electric). Data for adults and pediatric patients were collected in terms of CTDIvol and DLP values. The doses were estimated as a mean value of 10 patients on each CT unit. For pediatrics, doses were collected for four age groups (0-1year, >1-5years, >5-10years and >10-15years). Comparing different manufacturers and the same number of detector rows it was observed that, in case of 16 slices units, doses were very similar on Siemens and General Electric scanner. CTDIvol and DLP on Siemens scanner were 60 mGy and 1066 mGy·cm, respectively, while on General Electric those values were 66 mGy and 1050 mGy·cm. However, this trend was not observed in case of 64 slices units. CTDIvol and DLP values collected on Toshiba were much higher (177 mGy and 2109 mGy·cm) than in case of Siemens scanner (59 mGy and 1060 mGy·cm). Doses on 16 and 64 slices Siemens scanners were very similar, while on 4 slices were higher. Except in two units, doses were were in line with DRLs. In case of pediatrics, doses increase with patient age and again Siemens scanner showed the lowest values while the highest were observed on Toshiba. (authors)

  15. Cardiac Computed Tomography (Multidetector CT, or MDCT)

    Science.gov (United States)

    ... Disease Venous Thromboembolism Aortic Aneurysm More Cardiac Computed Tomography (Multidetector CT, or MDCT) Updated:Sep 19,2016 What is Computerized Tomography (CT)? CT is a noninvasive test that uses ...

  16. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  17. WE-G-209-02: CT

    International Nuclear Information System (INIS)

    Kofler, J.

    2016-01-01

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  18. WE-G-209-02: CT

    Energy Technology Data Exchange (ETDEWEB)

    Kofler, J. [Mayo Clinic (United States)

    2016-06-15

    Digital radiography, CT, PET, and MR are complicated imaging modalities which are composed of many hardware and software components. These components work together in a highly coordinated chain of events with the intent to produce high quality images. Acquisition, processing and reconstruction of data must occur in a precise way for optimum image quality to be achieved. Any error or unexpected event in the entire process can produce unwanted pixel intensities in the final images which may contribute to visible image artifacts. The diagnostic imaging physicist is uniquely qualified to investigate and contribute to resolution of image artifacts. This course will teach the participant to identify common artifacts found clinically in digital radiography, CT, PET, and MR, to determine the causes of artifacts, and to make recommendations for how to resolve artifacts. Learning Objectives: Identify common artifacts found clinically in digital radiography, CT, PET and MR. Determine causes of various clinical artifacts from digital radiography, CT, PET and MR. Describe how to resolve various clinical artifacts from digital radiography, CT, PET and MR.

  19. New horizons in cardiac CT

    International Nuclear Information System (INIS)

    Harder, A.M. den; Willemink, M.J.; Jong, P.A. de; Schilham, A.M.R.; Rajiah, P.; Takx, R.A.P.; Leiner, T.

    2016-01-01

    Until recently, cardiovascular computed tomography angiography (CCTA) was associated with considerable radiation doses. The introduction of tube current modulation and automatic tube potential selection as well as high-pitch prospective ECG-triggering and iterative reconstruction offer the ability to decrease dose with approximately one order of magnitude, often to sub-millisievert dose levels. In parallel, advancements in computational technology have enabled the measurement of fractional flow reserve (FFR) from CCTA data (FFR_C_T). This technique shows potential to replace invasively measured FFR to select patients in need of coronary intervention. Furthermore, developments in scanner hardware have led to the introduction of dual-energy and photon-counting CT, which offer the possibility of material decomposition imaging. Dual-energy CT reduces beam hardening, which enables CCTA in patients with a high calcium burden and more robust myocardial CT perfusion imaging. Future-generation CT systems will be capable of counting individual X-ray photons. Photon-counting CT is promising and may result in a substantial further radiation dose reduction, vastly increased spatial resolution, and the introduction of a whole new class of contrast agents.

  20. Design of respiration averaged CT for attenuation correction of the PET data from PET/CT

    International Nuclear Information System (INIS)

    Chi, Pai-Chun Melinda; Mawlawi, Osama; Nehmeh, Sadek A.; Erdi, Yusuf E.; Balter, Peter A.; Luo, Dershan; Mohan, Radhe; Pan Tinsu

    2007-01-01

    Our previous patient studies have shown that the use of respiration averaged computed tomography (ACT) for attenuation correction of the positron emission tomography (PET) data from PET/CT reduces the potential misalignment in the thorax region by matching the temporal resolution of the CT to that of the PET. In the present work, we investigated other approaches of acquiring ACT in order to reduce the CT dose and to improve the ease of clinical implementation. Four-dimensional CT (4DCT) data sets for ten patients (17 lung/esophageal tumors) were acquired in the thoracic region immediately after the routine PET/CT scan. For each patient, multiple sets of ACTs were generated based on both phase image averaging (phase approach) and fixed cine duration image averaging (cine approach). In the phase approach, the ACTs were calculated from CT images corresponding to the significant phases of the respiratory cycle: ACT 050phs from end-inspiration (0%) and end-expiration (50%), ACT 2070phs from mid-inspiration (20%) and mid-expiration (70%), ACT 4phs from 0%, 20%, 50% and 70%, and ACT 10phs from all ten phases, which was the original approach. In the cine approach, which does not require 4DCT, the ACTs were calculated based on the cine images from cine durations of 1 to 6 s at 1 s increments. PET emission data for each patient were attenuation corrected with each of the above mentioned ACTs and the tumor maximum standard uptake value (SUV max ), average SUV (SUV avg ), and tumor volume measurements were compared. Percent differences were calculated between PET data corrected with various ACTs and that corrected with ACT 10phs . In the phase approach, the ACT 10phs can be approximated by the ACT 4phs to within a mean percent difference of 2% in SUV and tumor volume measurements. In cine approach, ACT 10phs can be approximated to within a mean percent difference of 3% by ACTs computed from cine durations ≥3 s. Acquiring CT images only at the four significant phases for the

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT is well-suited for visualizing diseases or injury of important organs in the abdomen including the liver, kidney and spleen. CT is sometimes used to: diagnose appendicitis detect ...

  2. Advances in CT imaging for urolithiasis

    Directory of Open Access Journals (Sweden)

    Yasir Andrabi

    2015-01-01

    Full Text Available Urolithiasis is a common disease with increasing prevalence worldwide and a lifetime-estimated recurrence risk of over 50%. Imaging plays a critical role in the initial diagnosis, follow-up and urological management of urinary tract stone disease. Unenhanced helical computed tomography (CT is highly sensitive (>95% and specific (>96% in the diagnosis of urolithiasis and is the imaging investigation of choice for the initial assessment of patients with suspected urolithiasis. The emergence of multi-detector CT (MDCT and technological innovations in CT such as dual-energy CT (DECT has widened the scope of MDCT in the stone disease management from initial diagnosis to encompass treatment planning and monitoring of treatment success. DECT has been shown to enhance pre-treatment characterization of stone composition in comparison with conventional MDCT and is being increasingly used. Although CT-related radiation dose exposure remains a valid concern, the use of low-dose MDCT protocols and integration of newer iterative reconstruction algorithms into routine CT practice has resulted in a substantial decrease in ionizing radiation exposure. In this review article, our intent is to discuss the role of MDCT in the diagnosis and post-treatment evaluation of urolithiasis and review the impact of emerging CT technologies such as dual energy in clinical practice.

  3. Multimodality functional imaging of spontaneous canine tumors using 64CU-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT

    DEFF Research Database (Denmark)

    Hansen, Anders E; Kristensen, Annemarie T; Law, Ian

    2012-01-01

    To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated.......To compare the distribution and uptake of the hypoxia tracer (64)Cu-diacetyl-bis(N(4)-methylthiosemicarbazone) ((64)Cu-ATSM) PET/CT, FDG PET/CT and dynamic contrast enhanced perfusion CT (DCE-pCT) in spontaneous canine tumors. In addition (64)Cu-ATSM distribution over time was evaluated....

  4. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results

    International Nuclear Information System (INIS)

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful

  5. Comparison of Dynamic Contrast-Enhanced MRI and PET/CT in the Evaluation of Laryngeal Cancer After Inadequate CT Results.

    Science.gov (United States)

    Citil, Serdal; Dogan, Serap; Atilgan, Hasan Ikbal; Menzilcioglu, Mehmet Sait; Sahin, Tuna; Abdulrezzak, Ummuhan; Duymus, Mahmut; Ozturk, Mustafa

    2015-01-01

    To investigate the diagnostic value of dynamic magnetic resonance imaging (MRI) and positron emission tomography/computed tomography (PET/CT) for laryngeal cancers after inadequate CT results. The study comprised 45 patients investigated for primary laryngeal cancer or recurrence-residue in which CT was considered inadequate. A mass was found in 20 patients. Dynamic MRI and PET/CT were compared for diagnosis of mass, lymph node involvement, recurrence and residue. The dynamic curves formed in dynamic MRI were investigated for diagnostic contributions. The sensitivity and specificity of the dynamic MRI, for supraglottic, glottic and subglottic location, was 100%, 80%, and 92%; 100%, 85%, and 100%, respectively. In PET/CT the sensitivity and specificity were 100% for all of those localizations. For lymph node involvement, the sensitivity of dynamic MRI and PET/CT was 100%, the specificity was 100% and 93%, respectively. For recurrence-residue, the sensitivity and specificity of dynamic MRI were 86% and 67%, respectively, with 100% sensitivity and specificity in PET/CT. The sensitivity of type A curve for detection of malignancy was 40%, and specificity was 100%. When type A and B curves were included, the sensitivity was 100%. For patients investigated for laryngeal cancer in which CT is considered inadequate, dynamic MRI or PET/CT is useful.

  6. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  7. HERCA Position Paper. The process of CT dose optimisation through education and training and role of CT Manufacturers - October 2014. Addendum to HERCA CT Position paper: The process of CT dose optimisation through education and training and the role of the manufacturers - November 2015

    International Nuclear Information System (INIS)

    2014-10-01

    CT is the most important source of exposures to radiation in most developed countries today. For this reason CT dose optimisation is of great importance. In this position paper four main stakeholders who are involved in CT dose optimisation are identified. These are the CT manufacturers, the medical doctors, the CT technologists and the medical physicists. HERCA has been working together with the CT manufacturers and COCIR since 2010 following a self-commitment provided by COCIR in 2011. A number of dose optimisation and management tools have been developed by the CT manufacturers and are now available on modern CT scanners. These are presented in this paper. The process of CT dose optimisation can only be achieved if all the stakeholders involved work together as a team and are educated and trained in the use of CT dose optimisation and management tools. The CT manufacturers have an important role in this process. They need to ensure that their staff is properly trained, they need to provide proper education and training to the other three stakeholders involved and these three stakeholders need to find the time and be willing to be trained. This is clearly stated in this position paper with the aim of ensuring appropriate and effective use of CT imaging equipment. On 1 April 2015, HERCA organised a multi-stakeholder meeting kindly hosted by the French Nuclear Safety Authority (ASN) in its premises in Paris. The stakeholders included: - COCIR, supported by the main manufacturers of CT equipment (GE, Philips, Siemens and Toshiba), - The professional organisations: ESR, ESPR, EFRS, EANM, ESTRO and EFOMP, - The international organisations IAEA, EC, and the US FDA (present as observers). The objective of the meeting was to exchange views with a variety of key stakeholders on issues with regard to the optimised use of computed tomography (CT) scanners. The ultimate goal of this focus on dose optimisation is to ensure the best patient care by providing an optimised

  8. CT features of renal epithelioid angiomyolipomas

    International Nuclear Information System (INIS)

    Hu Xiaoyun; Fang Xiangming; Hu Chunhong; Chen Hongwei; Cui Lei; Bao Jian; Yao Xuanjun

    2010-01-01

    Objective: To explore the CT and pathological features of renal epithelioid angiomyolipoma (EAML). Methods: Clinical data and CT images from ten cases with EAML proved by surgery and pathology were retrospectively analyzed. All cases were performed with plain and contrast enhanced CT scans. Results: CT features: higher pre-contrasted density than kidney, bulging from kidney, absent of fat, markedly heterogeneous enhancement (quick wash-in and slow wash-out), big size without lobular sign, complete capsule with clear margin and mild necrostic area. Pathological features: diffuse sheets of epithelioid cells were found under microscopy with immunohistochemistrical findings including positivity for HMB-45 and negativity for EMA. Conclusion: Some specific CT features, which is correlated well with the pathological findings, provide helpful information in the primary diagnosis of EAML. (authors)

  9. CT and MR imaging of craniopharyngioma

    Energy Technology Data Exchange (ETDEWEB)

    Tsuda, M. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Takahashi, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Higano, S. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Kurihara, N. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology; Ikeda, H. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Neurosurgery; Sakamoto, K. [Tohoku Univ. School of Medicine, Sendai (Japan). Dept. of Radiology

    1997-05-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  10. CT and MR imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Tsuda, M.; Takahashi, S.; Higano, S.; Kurihara, N.; Ikeda, H.; Sakamoto, K.

    1997-01-01

    We reviewed imaging findings of CT and MR imaging in 20 cases of surgically confirmed craniopharyngioma in an attempt to determine their relation to patterns of tumor extent. The relationship between these patterns and the frequency of preoperative CT diagnosis and MR imaging diagnosis according to the surgical diagnosis were determined. The CT technique was superior to MR imaging in the detection of calcification. The MR imaging technique was superior to CT for determining tumor extent and provided valuable information about the relationships of the tumor to surrounding structures. Thus, CT and MR imaging have complementary roles in the diagnosis of craniopharyngiomas. In cases of possible craniopharyngioma, noncontrast sagittal T1-weighted images may enable the identification of the normal pituitary, possibly leading to the correct diagnosis. (orig.)

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... obtain CT images. It is known that high levels of radiation may cause cancer. However, CT scans result in a low-level exposure. Whether such levels cause cancer is debatable ...

  12. Fever of unknown origin: A value of 18F-FDG-PET/CT with integrated full diagnostic isotropic CT imaging

    International Nuclear Information System (INIS)

    Ferda, Jiri; Ferdova, Eva; Zahlava, Jan; Matejovic, Martin; Kreuzberg, Boris

    2010-01-01

    Aim: The aim of presented work is to evaluate the clinical value of 18 F-FDG-PET/CT in patients with fever of unknown origin (FUO) and to compare PET/CT finding with the results of the following investigation. Material and method: 48 patients (24 men, 24 women, mean age 57.6 years with range 15-89 years) underwent 18 F-FDG-PET/CT due to the fever of unknown origin. All examinations were performed using complex PET/CT protocol combined PET and whole diagnostic contrast enhanced CT with sub-millimeter spatial resolution (except patient with history of iodine hypersensitivity or sever renal impairment). CT data contained diagnostic images reconstructed with soft tissue and high-resolution algorithm. PET/CT finding were compared with results of biopsies, immunology, microbiology or autopsy. Results: The cause of FUO was explained according to the PET/CT findings and followed investigations in 44 of 48 cases-18 cases of microbial infections, nine cases of autoimmune inflammations, four cases of non-infectious granulomatous diseases, eight cases of malignancies and five cases of proved immunity disorders were found. In 46 cases, the PET/CT interpretation was correct. Only in one case, the cause was overlooked and the uptake in atherosclerotic changes of arteries was misinterpreted as vasculitis in the other. The reached sensitivity was 97% (43/44), and specificity 75% (3/4) respectively. Conclusion: In patients with fever of unknown origin, 18 F-FDG-PET/CT might enable the detection of its cause.

  13. Initial experience with AcQsim CT simulator

    International Nuclear Information System (INIS)

    Michalski, Jeff M.; Gerber, Russell; Bosch, Walter R.; Harms, William; Matthews, John W.; Purdy, James A.; Perez, Carlos A.

    1995-01-01

    Purpose: We recently replaced our university developed CT simulator prototype with a commercial grade spiral CT simulator (Picker AcQsim) that is networked with three independent virtual simulation workstations and our 3D radiation therapy planning (3D-RTP) system multiple workstations. This presentation will report our initial experience with this CT simulation device and define criteria for optimum clinical use as well as describe some potential drawbacks of the current system. Methods and Materials: Over a 10 month period, 210 patients underwent CT simulation using the AcQsim. An additional 127 patients had a volumetric CT scan done on the device with their CT data and target and normal tissue contours ultimately transferred to our 3D-RTP system. We currently perform the initial patient localization and immobilization in the CT simulation suite by using CT topograms and a fiducial laser marking system. Immobilization devices, required for all patients undergoing CT simulation, are constructed and registered to a device that defines the treatment table coordinates. Orthogonal anterior and lateral CT topograms document patient alignment and the position of a reference coordinate center. The volumetric CT scan with appropriate CT contrast materials administered is obtained while the patient is in the immobilization device. On average, more than 100 CT slices are obtained per study. Contours defining tumor, target, and normal tissues are drawn on a slice by slice basis. Isocenter definition can be automatically defined within the target volume and marked on the patient and immobilization device before leaving the initial CT simulation session. Virtual simulation is then performed on the patient data set with the assistance of predefined target volumes and normal tissue contours displayed on rapidly computed digital reconstructed radiographs (DRRs) in a manner similar to a conventional fluoroscopic radiotherapy simulator. Lastly, a verification simulation is

  14. Intraorbital wooden and bamboo foreign bodies: CT

    International Nuclear Information System (INIS)

    Uchino, A.; Kato, A.; Takase, Y.; Kudo, S.

    1997-01-01

    We describe the CT findings of intraorbital wooden and bamboo foreign bodies in the acute, subacute, and chronic stages. We examined four patients using CT a total of seven times. The CT findings were reviewed. There were three dry wooden foreign bodies. CT within a day of the accident demonstrated wooden foreign bodies as low density relative to surrounding orbital fat, while CT 8-29 days after the accident showed them as denser than the extraocular muscles. In the acute stage, dry wooden foreign bodies mimic air bubbles. Wooden foreign bodies in the subacute and chronic stages should be included in the differential diagnosis of intraorbital lesions of soft tissue density or above on CT of traumatised orbits. There was one dry bamboo foreign body. Within a day of the accident it was recognised as linear lesion isodense with fat. Therefore, such foreign bodies may be missed on CT when located in the orbital fat. (orig.)

  15. CT findings in patient with skull fractures

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Han Gi; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    CT scan has been inevitable method for patient with head trauma. CT scans of 94 cases, which were confirmed skull fracture by plain film, were reviewed for better and useful dealing of CT. The results were as follows: 1. Car accident was the most frequent cause of head injury. 2. No evidence of intracranial abnormality in CT scan of skull fractures on plane film was 45.7%, and alert mentality was 46.8% of skull fracture on skull fracture on simple film. 3. Detection rate on CT scan to skull fractures was 27.7%, but detection rate to depression fractures of skull fracture was 70.2%. 4. Mortality rate of patients with skull fracture was 10.6%. 5. Associated CT findings were pneumocephalus on CT scan 3.2%, contusion of edema 4.2%, epidural hematoma 16.0%, subdural hematoma 17.0%, subdural hygroma 2.1%, intracerebral hemorrhage 4.9%, and subarachnoid hemorrhage 2.0%.

  16. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  17. 3D-CT angiography with ultrafast CT in the diagnosis of pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Hamada, Seiki; Takamiya, Makoto; Imakita, Satoshi; Yamada, Naoaki; Takase, Kei; Iino, Misako; Nakanishi, Norifumi

    1995-01-01

    The usefulness of 3D-CT angiography (3D-CTA) with ultrafast CT (UFCT) in the diagnosis of pulmonary thromboembolism (PTE) was evaluated. UFCT was carried out in 10 patients with PTE (acute: 5 cases, chronic: 5 cases) and one case with pulmonary artery thrombosis secondary to pulmonary hypertension with atrial septal defect. CT scanning was performed with Imatron C-100XL and C-150L. For the imaging, single-slice step volume scan mode was used with scan time of 100 msec and slice thickness of 6 mm. Contiguous axial images were obtained after contrast enhancement with slice interval of 6 mm. 3D-CTA was reconstructed from 2D-CT images with workstation, and was compared with pulmonary angiograms (PAG) or operative findings. The images of 3D-CTA had good quality and they were more useful than 2D-CT images in better understanding of the configuration and the extent of the thrombi. In comparison with PAG, 3D-CTA gave equivalent information in terms of central pulmonary emboli. Moreover, 3D-CTA had advantages over PAG in demonstrating both the blood lumen and the thrombus on the same image with capability of multi-directional displays. 3D-CTA with UFCT is the useful non-invasive imaging modality in the diagnosis of PTE. (author)

  18. CT features of peritonitis carcinomatosa

    International Nuclear Information System (INIS)

    Ishii, Chikako; Kaneko, Kenji; Kato, Hitonari; Tada, Shinpei

    1988-01-01

    Fifty patients with peritonitis carcinomatosa were evaluated with computed tomography (CT). CT findings included evidence of mesenteric thickening (60 %), solid mass (20 %), loculated ascites (16 %), ascites (14 %), partly dilated intestine (10 %). Mesenteric thickening showed both intraperitoneal and subperitoneal metastasis. Arrested flow of ascitic fluid (loculated ascites) was one of the most predicting findings of peritonitis carcinomatosa. The seven false negative cases related to small metastatic foci, long distance between autopsy and the last CT examination, or paucity of intraabdominal fat. (author)

  19. Acute pancreatitis: staging with CT

    International Nuclear Information System (INIS)

    Gialeli, E.; Petrocheilou, G.; Georgaki, S.; Tzemailas, I.; Adraktas, A.; Charilas, G.; Patsiogiannis, V.

    2012-01-01

    Full text: Introduction: Computed Tomography (CT) is the imaging modality of choice for the diagnosis and staging of acute pancreatitis and its complications. Objectives and tasks: The purpose of this presentation is to demonstrate the findings in CT images which are useful for staging acute pancreatitis according to Balthazar, their significance and restrictions. Materials and methods: CT images from patients who were referred to our Department for an abdominal CT scan for the diagnosis or/and staging of acute pancreatitis were retrospectively studied. Results: In acute pancreatitis, CT helps to stage the severity of inflammatory process, to detect pancreatic necrosis and to depict local complications. CT severity index (CTSI), which was proposed by Balthazar et al, combines the grade of pancreatitis with the extent of pancreatic necrosis assigning points to the patients in order to find the severity index which scales from 0-10. More points are given for a higher grade of pancreatitis and for more extensive necrosis. Types of pancreatitis according to CTSI are: interstitial (Balthazar grade A-C), exudative (Balthazar grade D or E), necrotising (Balthazar grade E, CTSI:10) and central gland necrotising. Patients with pancreatitis but no collections or necrosis have an interstitial (mild) pancreatitis. In exudative pancreatitis there is normal enhancement of the entire pancreas associated with extensive peripancreatic collections. Necrotizing (severe) pancreatitis is characterized by protacted clinical course, high incidence of local complications and high mortality rate. Central gland necrosis is a subtype of necrotizing pancreatitis. Conclusions: The combination of CT imaging and clinical and laboratory evaluation allows the early diagnosis of acute pancreatitis. Acute pancreatitis may vary from a mild uneventful disease to a severe life-threatening illness with multisystemic organ failure. Thus, it is crucial to identify patients who are at high risk of severe

  20. Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

    International Nuclear Information System (INIS)

    Won Kim, Chang; Kim, Jong Hyo

    2014-01-01

    Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in

  1. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  2. CT analysis of missile head injury

    International Nuclear Information System (INIS)

    Besenski, N.; Jadro-Santel, D.; Jelavic-Koic, F.; Pavic, D.; Mikulic, D.; Glavina, K.; Maskovic, J.

    1995-01-01

    Between August 1991 and December 1992, CT was performed in 154 patients who had suffered missile head injury during the war in the Republic of Croatia. In 54% CT was performed 1-24 h after injury, and in 27% follow-up CT was also obtained. The wounds were penetrating, tangential or perforating (45%, 34% and 21%, respectively). Haemorrhage was the most frequent lesion in the brain (84%). Follow-up CT evolution of haemorrhage, oedema, cerebritis, abscess, secondary vascular lesions, necrosis, encephalomalacia and hydrocephalus. The most dynamic changes occurred 7-14 days after injury. In 14% of cases, deep cerebral lesions were found in the corpus callosum, septum pellucidum periventricular region and pons, although bone and shell fragments were in a different part of the brain parenchyma. Such lesions were found in penetrating injuries only. CT proved very useful for assessing the extent and type of lesions. Although different mechanisms of brain damage in missile head injury are known, here they are, to the best of our knowledge, shown for the first time by CT. (orig.)

  3. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    Science.gov (United States)

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  4. CT-guided puncture

    International Nuclear Information System (INIS)

    Noeldge, G.; Richter, G.M.; Grenacher, L.; Brado, M.; Kauffmann, G.W.

    1996-01-01

    Sonographic and CT-guided punctures allow the evaluation of suspected lesions in the head, thorax, abdomen, retroperitoneum and skeletal system. The size of the lesion to be evaluated determines the size and the diameter of the puncture needle. The quantity of the material obtained will be defined by the diameter of the needle, i.e. fine-needle biopsy is more adequate for cytological than for histological evaluation. Strict adherence to the indications and contraindications for puncture and painstaking performance of the procedure go a long why towards minimizing the complications. The advantage of CT-guided puncture, in contrast to an ultrasound-guided procedure, is visualization during the puncture procedure free from overshadowing. This permits punctures of lesions located deep in the thorax or the abdomen which are overshadowed by the lungs, by air in the small or large bowel or by bone structures. Moreover, this technique yields much more information about the tissues and organs surrounding the suspected lesion. This information is much more investigator-related with ultrasoundguided puncture. Therefore, the CT-guided puncture has become mandatory in the evaluation of suspected lesions. Moreover, using the same technique, percutaneous drainage of fluids in the interpleural space, abscesses in organs, hematomas, lymphoceles and urinomas; ablation of metastases; and sympathicolysis can be carried out. CT-guided puncture thus changes from a minimally invasive diagnostic procedure to a minimally invasive therapy. (orig./MG) [de

  5. CT evaluation of abdominal trauma

    International Nuclear Information System (INIS)

    Huang Ruiting

    2004-01-01

    Objective: An evaluation of CT diagnosis of abdominal trauma. Methods: CT appearance of abdominal trauma was analyzed retrospectively in 95 cases. thirty-three patients were cured by operation, and the other 59 patients received conservative treatment. Fifty-one patients out of 59 were seen healed or improved by a follow up CT scan after the conservative treatment. Results: The study included: 31 cases of splenic contusion, accompanying with hemoperitoneum in 25 cases; 3 cases of hepatic laceration; 33 cases of liver and spleen compound trauma accompanying with hemoperitoneum; 18 cases of renal contusion, with subcapsular hemorrhage in 12 cases; 4 cases of midriff colic; 3 cases of mesentery breach; 3 cases of digestive tract perforation. Conclusion: CT is sensitive and precise in evaluating abdominal trauma, providing important information for treatment. (author)

  6. CT of the pulmonary ligament

    International Nuclear Information System (INIS)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-01-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures

  7. CT of the pulmonary ligament

    Energy Technology Data Exchange (ETDEWEB)

    Godwin, J.D.; Vock, P.; Osborne, D.R.

    1983-08-01

    Most computed tomographic (CT) scans of the chest show the inferior pulmonary ligament and an associated septum in the lower lobe, although CT descriptions of these structures have not been reported. Conventional radiography of the ligament has relied on indirect signs: the position of the lower lobe in the presence of pneumothorax or pleural effusion, soft-tissue peaks along the upper surface of the diaphragm, and the rare traumatic paramediastinal pneumatocele (attributed to air in the ligament). CT clarifies the anatomic relations of the ligament and alterations caused by pleural effusion and pneumothorax. The ligament is probably responsible for some long linear shadows at the lung bases, and CT helps to distinguish these from scars, walls of bullae, and normal structures such as the phrenic nerve and the interlobar fissures.

  8. CT angiography and CT perfusion improve prediction of infarct volume in patients with anterior circulation stroke

    Energy Technology Data Exchange (ETDEWEB)

    Seeters, Tom van; Schaaf, Irene C. van der; Dankbaar, Jan Willem; Horsch, Alexander D.; Niesten, Joris M.; Luitse, Merel J.A.; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, Geert Jan; Kappelle, L.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Vos, Jan Albert [St. Antonius Hospital, Department of Radiology, Nieuwegein (Netherlands); Schonewille, Wouter J. [St. Antonius Hospital, Department of Neurology, Nieuwegein (Netherlands); Walderveen, Marianne A.A. van [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Wermer, Marieke J.H. [Leiden University Medical Center, Department of Neurology, Leiden (Netherlands); Duijm, Lucien E.M. [Catharina Hospital, Department of Radiology, Eindhoven (Netherlands); Keizer, Koos [Catharina Hospital, Department of Neurology, Eindhoven (Netherlands); Bot, Joseph C.J. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Visser, Marieke C. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Lugt, Aad van der [Erasmus MC University Medical Center, Department of Radiology, Rotterdam (Netherlands); Dippel, Diederik W.J. [Erasmus MC University Medical Center, Department of Neurology, Rotterdam (Netherlands); Kesselring, F.O.H.W. [Rijnstate Hospital, Department of Radiology, Arnhem (Netherlands); Hofmeijer, Jeannette [Rijnstate Hospital, Department of Neurology, Arnhem (Netherlands); Lycklama a Nijeholt, Geert J. [Medical Center Haaglanden, Department of Radiology, The Hague (Netherlands); Boiten, Jelis [Medical Center Haaglanden, Department of Neurology, The Hague (Netherlands); Rooij, Willem Jan van [St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Kort, Paul L.M. de [St. Elisabeth Hospital, Department of Neurology, Tilburg (Netherlands); Roos, Yvo B.W.E.M. [Academic Medical Center, Department of Neurology, Amsterdam (Netherlands); Meijer, Frederick J.A. [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Pleiter, C.C. [St. Franciscus Hospital, Department of Radiology, Rotterdam (Netherlands); Graaf, Yolanda van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Collaboration: Dutch acute stroke study (DUST) investigators

    2016-04-15

    We investigated whether baseline CT angiography (CTA) and CT perfusion (CTP) in acute ischemic stroke could improve prediction of infarct presence and infarct volume on follow-up imaging. We analyzed 906 patients with suspected anterior circulation stroke from the prospective multicenter Dutch acute stroke study (DUST). All patients underwent baseline non-contrast CT, CTA, and CTP and follow-up non-contrast CT/MRI after 3 days. Multivariable regression models were developed including patient characteristics and non-contrast CT, and subsequently, CTA and CTP measures were added. The increase in area under the curve (AUC) and R{sup 2} was assessed to determine the additional value of CTA and CTP. At follow-up, 612 patients (67.5 %) had a detectable infarct on CT/MRI; median infarct volume was 14.8 mL (interquartile range (IQR) 2.8-69.6). Regarding infarct presence, the AUC of 0.82 (95 % confidence interval (CI) 0.79-0.85) for patient characteristics and non-contrast CT was improved with addition of CTA measures (AUC 0.85 (95 % CI 0.82-0.87); p < 0.001) and was even higher after addition of CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001) and combined CTA/CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001). For infarct volume, adding combined CTA/CTP measures (R{sup 2} = 0.58) was superior to patient characteristics and non-contrast CT alone (R{sup 2} = 0.44) and to addition of CTA alone (R{sup 2} = 0.55) or CTP alone (R{sup 2} = 0.54; all p < 0.001). In the acute stage, CTA and CTP have additional value over patient characteristics and non-contrast CT for predicting infarct presence and infarct volume on follow-up imaging. These findings could be applied for patient selection in future trials on ischemic stroke treatment. (orig.)

  9. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging

    International Nuclear Information System (INIS)

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia; Halaweish, Ahmed

    2016-01-01

    Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE

  10. Technical Note: Improved CT number stability across patient size using dual-energy CT virtual monoenergetic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Michalak, Gregory; Grimes, Joshua; Fletcher, Joel; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Halaweish, Ahmed [Siemens Medical Solutions, Malvern, Pennsylvania 19355 (United States)

    2016-01-15

    Purpose: The purpose of this study was to evaluate, over a wide range of phantom sizes, CT number stability achieved using two techniques for generating dual-energy computed tomography (DECT) virtual monoenergetic images. Methods: Water phantoms ranging in lateral diameter from 15 to 50 cm and containing a CT number test object were scanned on a DSCT scanner using both single-energy (SE) and dual-energy (DE) techniques. The SE tube potentials were 70, 80, 90, 100, 110, 120, 130, 140, and 150 kV; the DE tube potential pairs were 80/140, 70/150Sn, 80/150Sn, 90/150Sn, and 100/150Sn kV (Sn denotes that the 150 kV beam was filtered with a 0.6 mm tin filter). Virtual monoenergetic images at energies ranging from 40 to 140 keV were produced from the DECT data using two algorithms, monoenergetic (mono) and monoenergetic plus (mono+). Particularly in large phantoms, water CT number errors and/or artifacts were observed; thus, datasets with water CT numbers outside ±10 HU or with noticeable artifacts were excluded from the study. CT numbers were measured to determine CT number stability across all phantom sizes. Results: Data exclusions were generally limited to cases when a SE or DE technique with a tube potential of less than 90 kV was used to scan a phantom larger than 30 cm. The 90/150Sn DE technique provided the most accurate water background over the large range of phantom sizes evaluated. Mono and mono+ provided equally improved CT number stability as a function of phantom size compared to SE; the average deviation in CT number was only 1.4% using 40 keV and 1.8% using 70 keV, while SE had an average deviation of 11.8%. Conclusions: The authors’ report demonstrates, across all phantom sizes, the improvement in CT number stability achieved with mono and mono+ relative to SE.

  11. CT in dental osseointegration

    International Nuclear Information System (INIS)

    Witte, D.

    1992-01-01

    Computerised tomography (CT) plays a key role in the pre-surgical evaluation of the alveolar process for titanium dental implants. The successful replacement of lost teeth by tissue integrated tooth root implants is a major advance in clinical dentistry. The paper will discuss briefly the history of osseointegration and how CT is now involved in helping the edentulous patient. CT is considered as a quick and convenient method of obtaining excellent anatomical information about the maxilla. Conventional tomography is difficult to obtain and does not provide valuable cross-sectional images. Exact height and width calculations can be made as well as screening out patients with advanced bone resorption. 3 refs. 6 figs

  12. CT in colon cancer

    International Nuclear Information System (INIS)

    Fujita, Nobuyuki; Hasegawa, Takashi; Kubo, Kozo; Ogawa, Hajime; Sato, Yukihiko; Tomita, Masayoshi; Hanawa, Makoto; Matsuzawa, Tohru; Nishioka, Ken

    1990-01-01

    CT pictures from 59 lesions of advanced colon cancer including rectal cancer were reviewed to evaluate a role of CT in preoperative staging diagnosis. CT findings were recorded following general rules for clinical and pathological studies on cancer of colon rectum and anus, proposed by Japanese society for cancer of colon and rectum. Tumors were detected in 90% of advanced colon cancers. Sensitivity in local extension (S factor) was 58.0%. Sensitivity in lymphonode involvement (N factor) was 50.0%. Sensitivity in final staging diagnosis, dividing colon cancer into two groups below st II and above st III, was 63.3%. Further study should be necessitated to provide useful information for preoperative staging diagnosis of colon cancer. (author)

  13. Attenuation correction of myocardial SPECT images with X-ray CT. Effects of registration errors between X-ray CT and SPECT

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Murase, Kenya; Mochizuki, Teruhito; Motomura, Nobutoku

    2002-01-01

    Attenuation correction with an X-ray CT image is a new method to correct attenuation on SPECT imaging, but the effect of the registration errors between CT and SPECT images is unclear. In this study, we investigated the effects of the registration errors on myocardial SPECT, analyzing data from a phantom and a human volunteer. Registerion (fusion) of the X-ray CT and SPECT images was done with standard packaged software in three dimensional fashion, by using linked transaxial, coronal and sagittal images. In the phantom study, and X-ray CT image was shifted 1 to 3 pixels on the x, y and z axes, and rotated 6 degrees clockwise. Attenuation correction maps generated from each misaligned X-ray CT image were used to reconstruct misaligned SPECT images of the phantom filled with 201 Tl. In a human volunteer, X-ray CT was acquired in different conditions (during inspiration vs. expiration). CT values were transferred to an attenuation constant by using straight lines; an attenuation constant of 0/cm in the air (CT value=-1,000 HU) and that of 0.150/cm in water (CT value=0 HU). For comparison, attenuation correction with transmission CT (TCT) data and an external γ-ray source ( 99m Tc) was also applied to reconstruct SPECT images. Simulated breast attenuation with a breast attachment, and inferior wall attenuation were properly corrected by means of the attenuation correction map generated from X-ray CT. As pixel shift increased, deviation of the SPECT images increased in misaligned images in the phantom study. In the human study, SPECT images were affected by the scan conditions of the X-ray CT. Attenuation correction of myocardial SPECT with an X-ray CT image is a simple and potentially beneficial method for clinical use, but accurate registration of the X-ray CT to SPECT image is essential for satisfactory attenuation correction. (author)

  14. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  15. National survey of CT colonography practice in Ireland

    LENUS (Irish Health Repository)

    Smyth, A.E.

    2016-06-01

    CT Colonography was first introduced to Ireland in 1999. Our aim of this study is to review current CT Colonography practices in the Republic of Ireland. A questionnaire on CT Colonography practice was sent to all non-maternity adult radiology departments in the Republic of Ireland with a CT scanner. The results are interpreted in the context of the recommendations on CT Colonography quality standards as published by the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) consensus statement in the journal of European Radiology in 2013. Thirty centres provide CT Colonography; 21 of which responded (70%). Each centre performs median 90 studies per year; the majority follow accepted patient preparation and image acquisition protocols. Seventy-six percent of the centres repsonded that the majority of patients imaged are symptomatic. Of the 51 consultant radiologists reading CT Colonography, 37 (73%) have attended a CT Colonography course. In 17 (81%) of the centres the studies are single read although 81% of the centres have access to a second radiologist’s opinion. Fourteen (67%) of the centres reported limited access to CT scanner time as the major limiting factor to expanding their service. CT Colonography is widely

  16. Additional value of integrated PET-CT in the detection and characterization of lung metastases: correlation with CT alone and PET alone

    International Nuclear Information System (INIS)

    Wever, W. de; Meylaerts, L.; Verschakelen, J.A.; Ceuninck, L. de; Stroobants, S.

    2007-01-01

    The purpose was evaluating retrospectively the additional value of integrated positron emission tomography (PET) and computed tomography (CT) in the detection of pulmonary metastases in comparison with CT and PET alone. Fifty-six lung nodules, divided into three groups according their size, detected in 24 consecutive patients with a known primary tumor were retrospectively evaluated with integrated PET-CT, CT and PET. The nature of these nodules was determined by either histopathology or a follow-up of at least 6 months. The CT and PET images of the integrated PET-CT were evaluated separately by a radiologist and a nuclear medicine physician, the integrated PET-CT images were evaluated by a chest radiologist and nuclear medicine physician in consensus. The investigators were asked to search lung nodules and to determine whether these nodules were metastases or not. Sensitivity and accuracy for CT, PET and integrated PET-CT for characterization of all pulmonary nodules were, respectively: 100%, 90%, 100% and 57%, 55%, 55%. There was no significant difference in the characterization of pulmonary nodules between integrated PET-CT and CT alone (P=1.000) and PET alone (P=0.1306). An accurate evaluation is only possible for lesions larger than 1 cm. (orig.)

  17. CT fogging effect with ischemic cerebral infarcts

    International Nuclear Information System (INIS)

    Becker, H.; Desch, H.; Hacker, H.; Pencz, A.; Frankfurt Univ.

    1979-01-01

    Systematic CT studies on ten patients with persistent ischemic cerebral infarct revealed a constant phenomenon, the fogging effect. The hypodense infarct at the beginning will be isodense, or close to isodense, on the plain CT during the second or third week and at a later stage will be hypodense again. The fogging infarcted area shows homogeneous intensive contrast enhancement. Knowledge of the fogging effect is important for correct interpretation of the CT image and the indication for contrast medium CT. CT without contrast medium may lead to misinterpretation during the second and third week after the onset of cerebral infarction. (orig.) [de

  18. Clinical PET/CT imaging. Promises and misconceptions

    International Nuclear Information System (INIS)

    Czernin, J.; Auerbach, M.A.

    2005-01-01

    PET/CT is now established as the most important imaging tool in oncology. PET/CT stages and restages cancer with a higher accuracy than PET or CT alone. The sometimes irrational approach to combine state of the art PET with the highest end CT devices should give way to a more reasonable equipment design tailored towards the specific clinical indications in well-defined patient populations. The continuing success of molecular PET/CT now depends more upon advances in molecular imaging with the introduction of targeted imaging probes for individualized therapy approaches in cancer patients and less upon technological advances of imaging equipment. (orig.)

  19. CT fogging effect with ischemic cerebral infarcts

    Energy Technology Data Exchange (ETDEWEB)

    Becker, H; Desch, H; Hacker, H; Pencz, A [Frankfurt Univ. (Germany, F.R.). Abt. fuer Neurologie; Frankfurt Univ. (Germany, F.R.). Abt. fuer Neuroradiologie)

    1979-01-01

    Systematic CT studies on ten patients with persistent ischemic cerebral infarct revealed a constant phenomenon, the fogging effect. The hypodense infarct at the beginning will be isodense, or close to isodense, on the plain CT during the second or third week and at a later stage will be hypodense again. The fogging infarcted area shows homogeneous intensive contrast enhancement. Knowledge of the fogging effect is important for correct interpretation of the CT image and the indication for contrast medium CT. CT without contrast medium may lead to misinterpretation during the second and third week after the onset of cerebral infarction.

  20. Tuberculous peritonitis: CT appearance

    International Nuclear Information System (INIS)

    Hanson, R.D.; Hunter, T.B.

    1985-01-01

    Rare, sporadic cases of tuberculous peritonitis do occur in the United States and other advanced countries. Because there are few descriptions of the CT appearance of the peritoneal forms of tuberculous (TB), this report illustrates a case of tuberculous peritonitis with prominent CT findings and discusses the differentiation of this entity from other, more common diseases

  1. Spinal CT scan, 1. Cervical and thoracic spines

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, Hiroshi (Aichi Medical Univ. (Japan))

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections.

  2. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    Science.gov (United States)

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  3. Empowering Teachers in Secondary School

    DEFF Research Database (Denmark)

    Christensen, Inger-Marie F.

    Konferencebidraget fortæller om overvejelserne ifm. design af et online kursus om undervisning i virtuelle verdner for folkeskolelærere. Overvejelserne drejer sig om indhold såvel som læringsteorier og undervisningsmetoder samt afviklingen af kurset online....

  4. Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

    International Nuclear Information System (INIS)

    Ravindran, V. R.; Sreelakshmi, C.; Vibin

    2008-01-01

    The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

  5. Iterative CT shading correction with no prior information

    Science.gov (United States)

    Wu, Pengwei; Sun, Xiaonan; Hu, Hongjie; Mao, Tingyu; Zhao, Wei; Sheng, Ke; Cheung, Alice A.; Niu, Tianye

    2015-11-01

    Shading artifacts in CT images are caused by scatter contamination, beam-hardening effect and other non-ideal imaging conditions. The purpose of this study is to propose a novel and general correction framework to eliminate low-frequency shading artifacts in CT images (e.g. cone-beam CT, low-kVp CT) without relying on prior information. The method is based on the general knowledge of the relatively uniform CT number distribution in one tissue component. The CT image is first segmented to construct a template image where each structure is filled with the same CT number of a specific tissue type. Then, by subtracting the ideal template from the CT image, the residual image from various error sources are generated. Since forward projection is an integration process, non-continuous shading artifacts in the image become continuous signals in a line integral. Thus, the residual image is forward projected and its line integral is low-pass filtered in order to estimate the error that causes shading artifacts. A compensation map is reconstructed from the filtered line integral error using a standard FDK algorithm and added back to the original image for shading correction. As the segmented image does not accurately depict a shaded CT image, the proposed scheme is iterated until the variation of the residual image is minimized. The proposed method is evaluated using cone-beam CT images of a Catphan©600 phantom and a pelvis patient, and low-kVp CT angiography images for carotid artery assessment. Compared with the CT image without correction, the proposed method reduces the overall CT number error from over 200 HU to be less than 30 HU and increases the spatial uniformity by a factor of 1.5. Low-contrast object is faithfully retained after the proposed correction. An effective iterative algorithm for shading correction in CT imaging is proposed that is only assisted by general anatomical information without relying on prior knowledge. The proposed method is thus practical

  6. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  7. Multidetector CT (MD-CT) in the diagnosis of uncertain open globe injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstetter, P.; Schreyer, A.G.; Jung, E.M.; Heiss, P.; Zorger, N. [Inst. fuer Roentgendiagnostik, Universitaetsklinikum Regensburg (Germany); Schreyer, C.I.; Framme, C. [Klink und Poliklinik fuer Augenheilkunde, Universitaetsklinikum Regensburg (Germany)

    2010-02-15

    Purpose: To evaluate the significance of multislice CT for the diagnosis of uncertain penetrating globe injuries. Materials and Methods: Based on a retrospective chart review between 2002 and 2007, we identified 59 patients presenting with severe ocular trauma with uncertain rupture of the globe due to massive subconjunctival and/or anterior chamber hemorrhage. The IOP (intraocular pressure) was within normal range in all patients. High resolution multidetector CT (MD-CT) scans (16 slice scans) with axial and coronar reconstructions were performed in all patients. The affected eye was examined for signs of penetrating injury such as abnormal eye shape, scleral irregularities, lens dislocation or intravitreal hemorrhages. Four experienced radiologists read the CT scans independently. Beside the diagnosis, the relevant morphological criteria and the optimal plane orientation (axial or coronar) were specified. The sensitivity, specificity, and negative and positive predictive value were calculated. Additionally the interobserver variability was determined by applying the Cohen's kappa test. Surgical sclera inspections were performed in all cases as a standard of reference. The evaluations of the CT examination were compared with the surgery reports. Results: 59 patients were evaluated (42 men, 17 women). The mean age was 29 years (range 7-91). In 17 patients a rupture of the globe was diagnosed during surgery. 12 of these 17 penetrating injuries (70.6%) were classified correctly by MDCT, 5 of the 17 (29.4%) were not detectable. 42 patients did not have an open globe injury. 41 of these patients were diagnosed correctly negative by MDCT, and one patient was classified false positive. This results in a sensitivity of 70% with a specificity of 98%. There was high inter-rater agreement with kappa values between 0.89-0.96. Most discrepancies were caused by wrong negative findings. The most frequent morphologic criteria for open globe injury were the deformation (n

  8. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    Energy Technology Data Exchange (ETDEWEB)

    Nattenmüller, Johanna, E-mail: johanna.nattenmueller@med.uni-heidelberg.de; Filsinger, Matthias, E-mail: Matthias_filsinger@web.de; Bryant, Mark, E-mail: mark.bryant@med.uni-heidelberg.de; Stiller, Wolfram, E-mail: Wolfram.Stiller@med.uni-heidelberg.de; Radeleff, Boris, E-mail: boris.radeleff@med.uni-heidelberg.de; Grenacher, Lars, E-mail: lars.grenacher@med.uni-heidelberg.de; Kauczor, Hans-Ullrich, E-mail: hu.kauczor@med.uni-heidelberg.de; Hosch, Waldemar, E-mail: waldemar.hosch@urz.uni-heidelberg.de [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology (Germany)

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  9. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    International Nuclear Information System (INIS)

    Nattenmüller, Johanna; Filsinger, Matthias; Bryant, Mark; Stiller, Wolfram; Radeleff, Boris; Grenacher, Lars; Kauczor, Hans-Ullrich; Hosch, Waldemar

    2014-01-01

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only

  10. Choroidal osteoma: US and CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Hun; Park, Sang Woo [Armed Forces Kwangju Hospital, Kwangju (Korea, Republic of); Kim, Jeong Hun [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2003-02-01

    The purpose of this study was to evaluate US and CT features of choroidal osteoma. US and CT scans of seven cases of choroidal osteoma occurring in six patients were retrospectively analyzed. We analysed US and CT findings with particular attention to the location, size, and shape of calcification associated with choroidal osteoma, and sought the possible cause of the tumor, if any. None of six patients had any possible cause related to choroidal osteoma. All of seven cases of choroidal osteoma were manifested as calcified mass which were located in the posterior wall of the eyeball near the juxtapapillary region. Calcification ranged in size from 1 to 2 cm and had curvilinear shape. Both US and CT were equally useful to evaluate choroidal osteoma. By depicting the characteristic calcification, US and CT are useful imaging modalities in evaluating choroidal osteoma.

  11. Ct enterography/ct abdomen and pelvis using neutral oral contrast. a new combination of natural products

    International Nuclear Information System (INIS)

    Aslam, M.O.

    2014-01-01

    Our purpose was to assess the performance of a new combination of neutral oral contrast for CT abdomen and CT Enterography in comparison with commercially available neutral oral contrast VoLumen. Seventy three consecutive patients were given sorbitol/CMC (Carboxy Methyl Cellulose) solution or VoLumen as oral contrast agent for abdominal computed tomography (CT) scan. 23 patients were male and 37 females. Age range was between 16 and 67 years. Since the use of CT scan for abdominal pathologies, there was need to separate bowel loops to localize the pathology. Three types of oral contrast can be used in CT-Scan abdomen; Positive, Neutral and negative. The above used contrasts are Neutral contrast these refers to agents that have an attenuation value similar to that of water (0-30 H).Our results show this new combination of Cc and Sorbitol to be equally good as VoLumen, for luminal distension and mural details, in duodenum and jejunum. While better than VoLumen for Ileal distension. (author)

  12. Examination of CT-AEC when the positioning changes after planning of CT scanning

    International Nuclear Information System (INIS)

    Esaki, Tooru; Yamazaki, Shoichi

    2009-01-01

    CT-automatic exposure control (AEC) controls tube current collecting information of the subject from positioning shooting. Because of this, we consider that CT-AEC does not get to operate properly if the body position of the test subject changes after the positioning shooting. However, we often experience in body positions of test subjects after the positioning shooting. In cases like this, we measured by using a phantom again to see how they affect the tube current value and standard deviation (SD) value comparing them to the normal scan where a body position does not change. As a result of the measurement, there was an impact on CT-AEC that optimization of tube current becomes insufficient if the body position of a test subject changes. As the image quality is deteriorated and radiation exposure increases because of this, taking positioning shooting again is required on the part of users and it's desirable on the part of manufacturers to develop CT-AEC that can be controlled with high accuracy. (author)

  13. Estimation of regional intrapulmonary moisture volumes by pulmonary CT numbers in CT views

    International Nuclear Information System (INIS)

    Nakamoto, Takaaki; Kato, Shiro; Yoshimura, Masaharu

    1987-01-01

    In order to study the regional intrapulmonary moisture volume in normal lungs, lungs with congestion, and lungs with increased blood flow, a series of 42 subjects underwent transverse computed tomography (CT) scanning performed at a total of 17 points corresponding to the upper (7), middle (3), and lower (7) lung fields. The subjects were divided into group I (n = 24, with left-sided heart failure), group II (n = 8, with left-to-right shunt heart disease), and group III (n = 10, normals). In group I, the pulmonary peripheral minus CT numbers were inversely correlated with the pulmonary wedge mean pressure and pulmonary arterial mean pressure; and were linearly correlated with pulmonary blood flow (PBF). In group II, they were inversely correlated with PBF and left-to-right shunt volume. The pulmonary pheripheral CT numbers were significantly higher in both groups I and II than group III. In group III, these CT numbers were higher in the posterior field than the anterior field in supine position. (Hou, H.L.)

  14. Algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images

    International Nuclear Information System (INIS)

    Ogino, Takashi; Egawa, Sunao

    1991-01-01

    New algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images were developed. One, designated plane weighting method, is to correct CT value in proportion to the position of the beam element passing through the voxel. The other, designated solid weighting method, is to correct CT value in proportion to the length of the beam element passing through the voxel and the volume of voxel. Phantom experiments showed fair spatial resolution in the transverse direction. In the longitudinal direction, however, spatial resolution of under slice thickness could not be obtained. Contrast resolution was equivalent for both methods. In patient studies, the reconstructed radiotherapy simulation image was almost similar in visual perception of the density resolution to a simulation film taken by X-ray simulator. (author)

  15. CT following US for possible appendicitis: anatomic coverage

    Energy Technology Data Exchange (ETDEWEB)

    O' Malley, Martin E. [University of Toronto, Princess Margaret Hospital, 3-920, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Alharbi, Fawaz [University of Toronto, Toronto General Hospital, NCSB 1C572, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Qassim University, Department of Medical Imaging, Buraydah, Qassim (Saudi Arabia); Chawla, Tanya P. [University of Toronto, Mount Sinai Hospital, Room 567, Joint Department of Medical Imaging, Toronto, Ontario (Canada); Moshonov, Hadas [University of Toronto, Joint Department of Medical Imaging, Toronto, Ontario (Canada)

    2016-02-15

    To determine superior-inferior anatomic borders for CT following inconclusive/nondiagnostic US for possible appendicitis. Ninety-nine patients with possible appendicitis and inconclusive/nondiagnostic US followed by CT were included in this retrospective study. Two radiologists reviewed CT images and determined superior-inferior anatomic borders required to diagnose or exclude appendicitis and diagnose alternative causes. This ''targeted'' coverage was used to estimate potential reduction in anatomic coverage compared to standard abdominal/pelvic CT. The study group included 83 women and 16 men; mean age 32 (median, 29; range 18-73) years. Final diagnoses were: nonspecific abdominal pain 50/99 (51 %), appendicitis 26/99 (26 %), gynaecological 12/99 (12 %), gastrointestinal 9/99 (10 %), and musculoskeletal 2/99 (2 %). Median dose-length product for standard CT was 890.0 (range, 306.3 - 2493.9) mGy.cm. To confidently diagnose/exclude appendicitis or identify alternative diagnoses, maximum superior-inferior anatomic CT coverage was the superior border of L2-superior border of pubic symphysis, for both reviewers. Targeted CT would reduce anatomic coverage by 30-55 % (mean 39 %, median 40 %) compared to standard CT. When CT is performed for appendicitis following inconclusive/nondiagnostic US, targeted CT from the superior border of L2-superior border of pubic symphysis can be used resulting in significant reduction in exposure to ionizing radiation compared to standard CT. (orig.)

  16. CT following US for possible appendicitis: anatomic coverage

    International Nuclear Information System (INIS)

    O'Malley, Martin E.; Alharbi, Fawaz; Chawla, Tanya P.; Moshonov, Hadas

    2016-01-01

    To determine superior-inferior anatomic borders for CT following inconclusive/nondiagnostic US for possible appendicitis. Ninety-nine patients with possible appendicitis and inconclusive/nondiagnostic US followed by CT were included in this retrospective study. Two radiologists reviewed CT images and determined superior-inferior anatomic borders required to diagnose or exclude appendicitis and diagnose alternative causes. This ''targeted'' coverage was used to estimate potential reduction in anatomic coverage compared to standard abdominal/pelvic CT. The study group included 83 women and 16 men; mean age 32 (median, 29; range 18-73) years. Final diagnoses were: nonspecific abdominal pain 50/99 (51 %), appendicitis 26/99 (26 %), gynaecological 12/99 (12 %), gastrointestinal 9/99 (10 %), and musculoskeletal 2/99 (2 %). Median dose-length product for standard CT was 890.0 (range, 306.3 - 2493.9) mGy.cm. To confidently diagnose/exclude appendicitis or identify alternative diagnoses, maximum superior-inferior anatomic CT coverage was the superior border of L2-superior border of pubic symphysis, for both reviewers. Targeted CT would reduce anatomic coverage by 30-55 % (mean 39 %, median 40 %) compared to standard CT. When CT is performed for appendicitis following inconclusive/nondiagnostic US, targeted CT from the superior border of L2-superior border of pubic symphysis can be used resulting in significant reduction in exposure to ionizing radiation compared to standard CT. (orig.)

  17. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  18. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria; Bastarrika, Gorka

    2012-01-01

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 ± 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 ± 58.3 mL) with respect to ECG-gated CT (142.7 ± 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 ± 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols

  19. Focal CT abnormality and epileptogenic focus

    International Nuclear Information System (INIS)

    Yagi, Kazuichi; Mihara, Tadahiro; Tottori, Takayasu; Matsuda, Kazumi; Watanabe, Yutaka; Seino, Masakazu

    1989-01-01

    In 31 patients with temporal lobe epilepsy, the precise site of epileptogenic focus was determined by means of a depth EEG recording as one of the presurgical evaluations. In 13 patients, a CT scan revealed focal lesions; 7 in the left temporal lobe and 6 in the right temporal lobe. In 5 of the 7 patients and in 5 of the 6 patients the epileptogenic foci were determined in the temporal lobe on the side of a CT lesion. However, in 2 of the patients with a CT lesion in the left temporal lobe, independent epileptogenic foci were found in both the temporal lobes, and in the other patient with a CT lesion in the right temporal lobe, they were found in the right frontal and left temporal lobes. Thus, the CT lesions agreed in lateralization and focality with the epileptogenic foci in 10 of the 13 patients (77%), but they disagreed in 3 (23%). A CT lesion disclosed in the temporal lobe does not necessarily indicate the side and/or site where the epileptogenic focus may be localized. Although exceptions may be made, spatial disagreement was exemplified between the CT lesion and epileptogenic focus. Therefore, extreme caution has to be taken on the side and/or site of the epileptogenic focus when functional surgical indication is to be made. (author)

  20. CT in three cases of syringomyelia

    International Nuclear Information System (INIS)

    Ugawa, Yoshikazu; Sakuta, Manabu; Yagishita, Akira; Inoue, Kiyoharu.

    1983-01-01

    We presented the results of our experience with metrizamide computed tomographic myelography (MCTM) and myelography in three cases of syringomyelia. In case 1, MCTM revealed Chiari malformation, even though this malformation was not clear in the myelography. In case 3, Chiari malformation was apparent in MCTM and in the myelography. In case 1, CT of the spinal cord without enhancement (plain CT) showed a syrinx in the cervical spinal cord, and MCTM made the syrinx clearer with enhancement. MCTM also demonstrated a cavity at the levels of Th 6 and L 1 of the vertebra. In case 2, a syrinx was disclosed in MCTM, in spite of normal myelography. In case 3, myelography demonstrated a spinal cord swelling. MCTM made a syrinx less clear than plain CT. Not only MCTM but also plain CT is an excellent method for the recognition of syringomyelia. The non-invasive plain CT is the first choice of the examinations in cases with syrinogomyelia, because MCTM may make a syrinx obscure. CT and MCTM have to be performed at many levels of the spinal cord in case with syringomyelia. CT or MCTM may demonstrate a syrinx or a cavity at the levels of the spinal cord, where no syrinx is suspected to exist by clinical features, as well as at the levels appearing normal in the myelography. (author)

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Using a multidetector CT unit to examine ... CT scans should have no immediate side effects. Risks The risk of serious allergic reaction to contrast ...

  2. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... vessels. CT scans may be performed on newborns, infants and older children. top of page What are ... heart and blood vessels in children, even newborn infants. Except for the chest x-ray, CT is ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... trauma to blood vessels or lung CT is well-suited for visualizing diseases or injury of important ... detailed images of many types of tissue as well as the lungs, bones, and blood vessels. CT ...

  4. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? In many ways, CT scanning is like other ... accurate. A major advantage of CT is its ability to image bone, soft tissue and blood vessels ...

  5. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... outside of the CT scanner itself is very low. If you suspect you may be pregnant, however, ... cause cancer. However, CT scans result in a low-level exposure. Whether such levels cause cancer is ...

  6. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... prescribed procedure with your doctor, the medical facility staff and/or your insurance provider to get a ...

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... images or pictures of the inside of the body. The cross-sectional images generated during a CT ... be performed to evaluate blood vessels throughout the body. With CT, it is possible to obtain very ...

  8. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... a very detailed multidimensional view of the body's interior. Refinements in detector technology allow new CT scanners ... to read. top of page What will my child experience during and after the procedure? CT exams ...

  9. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces ... of imaging in these procedures in children. A diagnosis determined by CT scanning may eliminate the need ...

  10. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... with the CT technologist or nurse at the time of the CT examination. If your child has ... detectors rotate around the patient. At the same time, the examination table is moving through the scanner, ...

  11. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... such as inflammation of the bronchi (breathing passages) birth defects trauma to blood vessels or lung CT ... used to: diagnose appendicitis detect abdominal tumors or birth defects In the pelvic region, CT scans can ...

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... medications and allergies. Inform your doctor and the technologist prior to the exam if your child has ... exam. This can be discussed with the CT technologist, the specialist who will be performing the CT ...

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... is Children's CT? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic ... is used to evaluate: complications from infections such as pneumonia a tumor that arises in the lung ...

  14. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... best for your child. top of page Additional Information and Resources The Alliance for Radiation Safety in ...

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... also be discussed with the CT technologist or nurse at the time of the CT examination. If ... difficulty breathing, you should notify the technologist or nurse, as it may indicate a more severe allergic ...

  16. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? In many ways, CT scanning is like other ... scanning is painless, noninvasive and accurate. A major advantage of CT is its ability to image bone, ...

  17. Side-by-side reading of PET and CT scans in oncology: Which patients might profit from integrated PET/CT?

    International Nuclear Information System (INIS)

    Reinartz, Patrick; Wieres, Franz-Josef; Schneider, Wolfram; Schur, Alexander; Buell, Ulrich

    2004-01-01

    Most early publications on integrated positron emission tomography/computed tomography (PET/CT) devices have reported the new scanner generation to be superior to conventional PET. However, few of these studies have analysed the situation where, in addition to PET, a current CT scan is available for side-by-side viewing. This fact is important, because combined PET/CT or a software-based fusion of the two modalities may improve diagnosis only in cases where side-by-side reading of PET and CT data does not lead to a definitive diagnosis. The aim of this study was to analyse which patients will profit from integrated PET/CT in terms of lesion characterization. A total of 328 consecutively admitted patients referred for PET in whom a current CT scan was available were included in the study. The localization of all pathological PET lesions, as well as possible infiltration of adjacent anatomical structures, was assessed. Of 467 pathological lesions, 94.0% were correctly assessed with respect to localization and infiltration by either conventional PET alone (51.6%) or combined reading of PET and the already existing CT scans (42.4%). Hence, in only 6.0% of all lesions, affecting 6.7% of all patients, could evaluation have profited from integrated PET/CT. We conclude that side-by-side viewing of PET and CT scans is essential, as in 42.4% of all cases, combined viewing was important for a correct diagnosis in our series. In up to 6.7% of patients, integrated PET/CT might have given additional information, so that in nearly 50% of patients some form of combined viewing of PET and CT data is needed for accurate lesion characterization. (orig.)

  18. CT findings of slilcosis

    International Nuclear Information System (INIS)

    Jung, Dong Hee; Kim, Kun Il; Son, Hyun Ju; Ro, Young Jin; Jung, Doo Young; Park, Jae Yeong; Lee, Jun Woo; Kim, Byung Soo

    1996-01-01

    To describe chest radiographic and CT findings of silicosis, and to compare their findings. Ten coal miners and six stonemasons were included in this study. All were male and their mean age was 53.1. The mean duration of dust exposure was 15.2 years(range, 5-30 years) in coal miners and 25.3 years(range, 15-35 years) in stonemasons. Chest radiographs(n=16), conventional CT scans(n=4), and high resolution CT(HRCT) scans(n=13) were evaluated. Parenchymal abnormalities were interpreted on the basis of ILO standard films(1980) in chest radiographs and on the basis of CAP(College of American Pathologists, 1979) in CT(HRCT) films. Chest radiographs revealed large opacities(n=8), small opacities(n=6), and normal findings(n=2). Type r(n=4) and category 1/1(n=2) were most common for small opacities, while for large opacities, category B(n=4) and category c(n=4) were most common. These small and large opacities were located predominantly in the area of the upper and middle lung. Associated findings were emphysema(n=7), eggshell nodal calcifications(n=3), pneumothorax(n=3), C-P angle blunting(n=4), and pleural thickening(n=1). CT scans revealed micronodules(n=16), nodules(n=3), and progressive massive fibrosis(PMF, n=8). All these lesions were located in the upper and middle lungs, especially in the central portion of the posterior lung. PMF showed diffuse and homogenous(n=3) and puntate(n=2) calcifications, cavitations(n=5), air bronchograms(n=3), and necrosis(n=1). Peripheral paracicatrical emphysema was associated with PMF(n=8). Other findings were pneumothorax(n=4), emphysema(n=10), hilar and mediastinal nodal enlargement(n=11) bronchial wall thick- enings(n=6), bronchiectasis(n=1), pleural thickening(n=7), parenchymal fibrosis(n=1), and pulmonary tuberculosis(n=2). Small and large opacities in chest radiographs and micronodules, nodules, and PMFs in CT (HRCT) films were located predominately in the upper and middle lungs, especially in the central portion of the

  19. CT-SPECT fusion to correlate radiolabeled monoclonal antibody uptake with abdominal CT findings

    International Nuclear Information System (INIS)

    Kramer, E.L.; Noz, M.E.; Sanger, J.J.; Megibow, A.J.; Maguire, G.Q.

    1989-01-01

    To enhance the information provided by computed tomography (CT) and single photon emission computed tomography (SPECT) performed with radiolabeled, anti-carcinoembryonic antigen monoclonal antibody (MoAb), the authors performed fusion of these types of images from eight subjects with suspected colorectal adenocarcinoma. Section thickness and pixel size of the two studies were matched, coordinates of corresponding points from each study were identified, and CT sections were translated, rotated, and reprojected to match the corresponding SPECT scans. The CT-SPECT fusion enabled identification of anatomic sites of tumor-specific MoAb accumulation in four cases, showed non-specific MoAb accumulation in two, and helped confirm information only suggested by the two studies separately in one

  20. Biplane CT in sellar and parasellar tumors, (2)

    International Nuclear Information System (INIS)

    Sadamoto, Kazuhiko; Sakaki, Saburo; Matsuoka, Kenzo; Goishi, Junji; Sokabe, Takashi.

    1980-01-01

    Biplane CT images of 30 cases of sellar and parasellar tumors were studied. All 3 cases of meningioma were discovered by biplane CT (the diagnostic rate, 100%). As biplane CT could exclude partial volume effects, biplane CT images could demonstrate a fine structure and the position of parasellar or skull-base meningioma. As features of craniopharyngioma visualized on biplane CT images were variable, 7 of 9 cases of craniopharyngioma were detected by biplane CT (the diagnostic rate, 80%). When contrast enhancement on biplane CT images was marked, sometimes differencial diagnosis of craniopharyngioma and other suprasellar tumors was difficult. In all 18 cases of chromophobe adenoma, biplane CT images successfully demonstrated the location and extension of the tumors including cystic tumor (the diagnostic rate, 100%). In addition, 2 cases of giant aneurysm were presented in this study as examples of the differential diagnosis of pituitary and supraseller tumors. Biplane CT images showed mainly the location and the size of aneurysm as a mass lesion: therefore, cerebral angiography including vertebral arteriography was necessary for making an exact diagnosis of aneurysm. (Tsunoda, M)