WorldWideScience

Sample records for ct temporal bone

  1. High resolution CT of temporal bone trauma

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Eun Kyung [Korea General Hospital, Seoul (Korea, Republic of)

    1986-10-15

    Radiographic studies of the temporal bone following head trauma are indicated when there is cerebrospinal fluid otorrhea or rhinorrhoea, hearing loss, or facial nerve paralysis. Plain radiography displays only 17-30% of temporal bone fractures and pluridirectional tomography is both difficult to perform, particularly in the acutely ill patient, and less satisfactory for the demonstration of fine fractures. Consequently, high resolution CT is the imaging method of choice for the investigation of suspected temporal bone trauma and allows special resolution of fine bony detail comparable to that attainable by conventional tomography. Eight cases of temporal bone trauma examined at Korea General Hospital April 1985 through May 1986. The results were as follows: Seven patients (87%) suffered longitudinal fractures. In 6 patients who had purely conductive hearing loss, CT revealed various ossicular chain abnormality. In one patient who had neuro sensory hearing loss, CT demonstrated intract ossicular with a fracture nearing lateral wall of the lateral semicircular canal. In one patient who had mixed hearing loss, CT showed complex fracture.

  2. CT of temporal bone - IV. inner ear

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Jae Yoon; Sung, Kyu Bo; Youn, Eun Kyoung; Park, Youn Kyeung; Lee, Young Uk [Koryo general Hospital, Seoul (Korea, Republic of)

    1990-07-15

    Temporal bone CT was done in 697 patients from April 1985 to October 1989. The abnormal findings were seen in 453 patients, which were chronic otitis media in 355 patients, fracture in 49 patients and congenital anomaly in 44 patients, etc. The abnormal findings of inner ear were observed on 46 patients. The results were summarized as follows : 1. The incidence of inner ear involvement by chronic otitis media was 7.3% (26/355 : labyrinthine fistula in 17 patients, labyrinthitis ossificans in 9 patients). Labyrinthine fistula was most commonly located on lateral semicircular canal (15/17, 88.2%). 2. Fusion of vestibule with lateral semicircular canal and formation of common cavity was demonstrated incidentally in 5 patients (0.7% of total number of temporal bone CT), and bilateral in 3 patients. 3. The incidence of inner ear anomaly in congenital ear anomaly was 11.4% (5/44). All cases were bilateral and three patients showed associated middle ear anomaly. 4. The incidence of involvement of bony labyrinth in temporal bone fracture was 10.2% (5/49). Labyrinthine fracture was seen all patients of transverse(3) and mixed fracture(1). In longitudinal fracture, labyrinthine fracture was seen in 2.2% (1/45). 5. Others were traumatic labyrinthitis ossificans(1), intracanalicular acoustic neuroma(3) and facial nerve neuroma(1)

  3. [CT findings of the temporal bones in Waardenburg's syndrome].

    Science.gov (United States)

    Irie, K; Ogata, H; Mitsudome, A

    1990-05-01

    We reported three cases of Waardenburg's syndrome and discussed CT findings of the temporal bones. Two cases of these patients were mother and daughter. Case 1, a two-year-old girl, had lateral displacement of the medial canthi, a broad nasal root, hetero-chromic iridis, left ptosis, albinotic fundus, and bilateral congenital deafness. CT findings of the temporal bones showed enlarged vestibules, short lateral semicircular canal, and absent right posterior semicircular canal. The mother had congenital deafness, heterochromia iridis, and a white forelock and showed similar abnormal CT findings of the temporal bones. Case 2, a one-year-old boy, had lateral displacement of the medial canthi, a broad nasal root, partial heterochromia iridis, albinotic fundus, and bilateral congenital deafness. CT findings of the temporal bones showed enlarged vestibules and absence of semicircular canals except the right lateral semicircular canal. These cases were diagnosed as Waardenburg's syndrome on the basis of the characteristic features.

  4. CT-scanning of ancient Greenlandic Inuit temporal bones

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Videbaek, H

    1992-01-01

    bones. The CT-scans showed sclerosing and obliteration of the air cells and even destruction of the cellular septae, and a high degree of irregularity of the cells. Sclerosing of the surrounding bone tissue was also found. The findings in one cranium were dubious and could both be regarded...... as a congenital malformation or an infection in infanthood. CT-scan confirms and even adds to the results of conventional X-ray of temporal bones making hypotheses of paleopathology more reliable. The findings also support the environmental theory of pneumatization of the air cell system in the temporal bones....

  5. Craniofacial and temporal bone CT findings in cleidocranial dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, Guido E. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Clinica Alemana de Santiago, Departamento de Imagenes, Santiago (Chile); Caruso, Paul A.; Curtin, Hugh D. [Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Radiology, Boston, MA (United States); Small, Juan E. [Massachusetts General Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Radiology, Boston, MA (United States); Jyung, Robert W. [Massachusetts Eye and Ear Infirmary and Harvard Medical School, Department of Otology, Boston, MA (United States); Troulis, Maria J. [Massachusetts General Hospital and Harvard Medical School, Department of Oral and Maxillofacial Surgery, Boston, MA (United States)

    2008-08-15

    Cleidocranial dysplasia (CCD) is a multistructural polyostotic genetic disorder that results from mutation of the CBFA1 gene. Hearing loss is a frequent finding in CCD. We describe the CT craniofacial findings in CCD and provide a comprehensive discussion of the CT temporal bone findings in these patients. (orig.)

  6. MR and CT findings of temporal bone langerhans cell histiocytosis

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Ig; Lee, Hee Jung; Kim, Heung Sik [Keimyung Univ. School of Medicine, Dongsan Medical Center, Taegu (Korea, Republic of)

    2001-11-01

    To describe the MRI and CT findings of temperal bone langerhans cell histiocytosis. The MRI (n=8) and CT (n=7) findings of nine lesions of temporal bone Langerhans cell histiocytosis in six children were retrospectively reviewed. Eight lesions were pathologically confirmed and one was clinically diagnosed. The findings were analyzed for bilaterality, location, lesion extent, signal intensity, the attenuation of soft tissue lesions seen at MRI or precontrast CT, enhancement pattern at MRI or CT, and the pattern of bony destruction at CT. Bilateral involvement was present in three of six patients (50%). Lesions were most frequently located in the mastoid (n=8, 89%), followed by the petrous ridge (n=6, 67%), and the squamous portion (n=3, 33%). Seven (78%) lesions extended to the ipsilateral cavernous sinus (n=3), sphenoid bone (n=3), orbit (n=2), or epidural space (n=2). The signals of the soft tissue lesions were isointense in five cases (63%) on T1-weighted images and hyperintense in six (75%) at MRI, and homogeneous in five (71%) at CT. All lesions demonstrated bony destruction without periosteal reaction and five (71%) showed ill-defined destruction, with crossing sutures. Familiarity with findings of predominant mastoid involvement, isointense or isodense soft tissue lesions seen on T1-weighted images or at precontrast CT, with relatively homogeneous enhancement at CT, and irregular bony destruction with crossing sutures may be helpful in narrowing the diagnosis of temporal bone langerhans cell histiocytosis.

  7. Chondromyxoid fibroma of the temporal bone: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Tarhan, N.C.; Yologlu, Z.; Tutar, N.U.; Coskun, M.; Agildere, A.M. [Baskent Univ. School of Medicine, Bahcelievler Ankara (Turkey). Dept. of Radiology; Arikan, U. [Baskent Univ. School of Medicine, Bahcelievler Ankara (Turkey). Dept. of Pathology

    2000-10-01

    We present the case of a 44-year-old woman with chondromyxoid fibroma of temporal bone origin. Since this is the least common bone tumor of cartilaginous origin, it is highly unusual to find this tumor in the skull. In fact, the literature describes 18 cases of this form of neoplasia arising in the skull, only 4 of these having originated in the temporal bone. To date, the radiological features of these tumors, and especially features detected using the latest imaging modalities, have not been described in detail. This report is unique in that it is the first to present a case of chondromyxoid fibroma of the temporal bone accompanied by detailed CT and MRI findings. (orig.)

  8. Anatomic and Quantitative Temporal Bone CT for Preoperative Assessment of Branchio-Oto-Renal Syndrome.

    Science.gov (United States)

    Ginat, D T; Ferro, L; Gluth, M B

    2016-12-01

    We describe the temporal bone computed tomography (CT) findings of an unusual case of branchio-oto-renal syndrome with ectopic ossicles that are partially located in the middle cranial fossa. We also describe quantitative temporal bone CT assessment pertaining to cochlear implantation in the setting of anomalous cochlear anatomy associated with this syndrome.

  9. Three-dimensional CT imaging with a helical scan on temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Honghan; Hiraishi, Kumiko; Uesugi, Yasuo; Sakakura, Atsushi; Yoshikawa, Shuji; Shimizu, Takaya; Sueyoshi, Kozo; Narabayashi, Isamu [Osaka Medical Coll., Takatsuki (Japan)

    1996-06-01

    To evaluate the usefulness of three-dimensional (3D) CT on the lesions of temporal bone, we studied 19 patients with disorders on the region of temporal bone by high speed helical CT. The results showed that 8 patients with congenital hearing disorder had deficiency of the auditory ossicles, 2 patients with chronic otitis media had deformity and shortness of the auditory ossicles, 4 patients with trauma had fracture of the temporal bone (1 patient was complicated by doubtful fracture of the incus), 5 patients (4 patients with acquired hearing disorder and 1 patient with otorrhea) had space-occupying lesions. 3-D helical CT could detect abnormal findings on all the patients and it was an important examination for the temporal bone. (author)

  10. CT-scanning of the temporal bone in an inner ear malformation

    Energy Technology Data Exchange (ETDEWEB)

    Murata, K.; Hosoi, H.; Isono, M.; Ohta, F. (Kinki Univ., Higashi-Osaka, Osaka (Japan))

    1982-05-01

    CT-scanning of the temporal bone revealed a fine contour of the inner ear anomaly in a 8-year-old boy with total deafness on the right. In the inner ear there was a globular mass with a small protrusion anteriorly and with a probably immature superior semi-circular canal. The globular mass was considered to be the utriculosaccular capsule, and the anterior protrusion to be an incipient cochlear duct. CT-scanning of the temporal bone may bring significant progress in diagnosis of inner ear anomalies. Detailed configuration of an inner ear may be shown before histological examination.

  11. Incidental internal carotid artery calcifications on temporal bone CT in children

    Energy Technology Data Exchange (ETDEWEB)

    Koch, Bernadette; Jones, Blaise [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); Blackham, Aaron [University of Cincinnati College of Medicine, Cincinnati, OH (United States)

    2007-02-15

    Incidental internal carotid artery (ICA) calcifications are occasionally noted on CT images of the brain and temporal bone. In adults, incidental calcifications have been correlated with increased incidence of hypercholesterolemia, cardiac disease, diabetes and carotid stenosis. To determine the incidence of incidental calcifications of the carotid siphon on temporal bone CT in children. We retrospectively reviewed 24 months of consecutive temporal bone CT examinations in children aged 18 years and younger. CT examinations on 663 patients were reviewed and the presence or absence of ICA calcifications was ranked as absent, questionable or definitive. In patients in whom definitive calcifications were identified, hospital charts were reviewed for evidence of diabetes mellitus, hypercholesterolemia, hypertriglyceridemia, hyperlipidemia and chronic renal disease as potential causes of early atherosclerosis. Of the 663 patients, 25% had definitive calcifications within the wall of the ICA: 6% of children younger than 2 years and 28% of children 12-19 years of age. Incidentally noted ICA calcifications are a common finding on temporal bone CT in children, most likely a physiologic response to turbulent flow at natural bends in the artery rather than secondary to underlying disease predisposing to early atherosclerotic calcification. (orig.)

  12. Three dimensional CT of stapes. Stapedial imagings in dry temporal bone and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Edamatsu, Hideo; Kubota, Osamu; Yamashita, Koichi [Kanazawa Medical Univ., Ishikawa (Japan)

    1995-03-01

    This study was performed to evaluate the usefulness and limitations of three dimensional (3-D) imagings of stapes in the middle ear by high speed helical CT. One dissected human temporal bone, ten normal and diseased ears were scanned with a slice of 1.0 mm and reconstructed in a thickness of 0.2-0.5 mm. Every specimen of 3-D can be observed in any plane and from any direction. Ossicular imagings of the temporal bone in 3-D were reconstructed as if the malleus, incus and stapes were observed under microscope. The whole structure of stapes was impossible to be represented by two dimensional CT heretofore in use, but 3-D in our study showed the head, crus and foot plate of the stapes in detail. Stapedial imagings of 3-D CT in normal ears showed the same findings as those recorded in temporal bone. Preoperative diagnostic findings of ossicles in the affected ears were very useful. Especially in ossicular anomalies, 3-D CT was positive in diagnosis and its accuracies were confirmed with operative observation. For the postoperative evaluation concerning the ossicular reconstruction, i.e. TORP and PORP, 3-D CT was also important method. It could present an anatomical relation between those prosthesis and the oval window. High speed helical CT can scan an object more quickly and clearly than formerly used CT, and its biological damage for human is less than that of the others. 3-D CT can be more clearly reconstructed with helical CT than former CT. (author).

  13. Multimodal imaging of the human temporal bone: A comparison of CT and optical scanning techniques

    Science.gov (United States)

    Voie, Arne H.; Whiting, Bruce; Skinner, Margaret; Neely, J. Gail; Lee, Kenneth; Holden, Tim; Brunsden, Barry

    2003-10-01

    A collaborative effort between Washington University in St. Louis and Spencer Technologies in Seattle, WA has been undertaken to create a multimodal 3D reconstruction of the human cochlea and vestibular system. The goal of this project is to improve the accuracy of in vivo CT reconstructions of implanted cochleae, and to expand the knowledge of high-resolution anatomical detail provided by orthogonal-plane optical sectioning (OPFOS). At WUSL, computed tomography (CT) images of the cochlea are used to determine the position of cochlear implant electrodes relative to target auditory neurons. The cochlear implant position is determined using pre- and post-operative CT scans. The CT volumes are cross-registered to align the semicircular canals and internal auditory canal, which have a unique configuration in 3-D space. The head of a human body donor was scanned with a clinical CT device, after which the temporal bones were removed, fixed in formalin and trimmed prior to scanning with a laboratory Micro CT scanner. Following CT, the temporal bones were sent to the OPFOS Imaging Lab at Spencer Technologies for a further analysis. 3-D reconstructions of CT and OPFOS imaging modalities were compared, and results are presented. [Work supported by NIDCD Grants R44-03623-5 and R01-00581-13.

  14. CT-MR image data fusion for computer assisted navigated neurosurgery of temporal bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Stefan Franz [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)]. E-mail: stefan.nemec@meduniwien.ac.at; Donat, Markus Alexander [Department of Neurosurgery, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Mehrain, Sheida [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Friedrich, Klaus [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Krestan, Christian [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Matula, Christian [Department of Neurosurgery, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Imhof, Herwig [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria); Czerny, Christian [Department of Radiology/Osteology, Medical University Vienna, Waehringerguertel 18-20, A-1090 Vienna (Austria)

    2007-05-15

    Purpose: To demonstrate the value of multi detector computed tomography (MDCT) and magnetic resonance imaging (MRI) in the preoperative work up of temporal bone tumors and to present, especially, CT and MR image fusion for surgical planning and performance in computer assisted navigated neurosurgery of temporal bone tumors. Materials and methods: Fifteen patients with temporal bone tumors underwent MDCT and MRI. MDCT was performed in high-resolution bone window level setting in axial plane. The reconstructed MDCT slice thickness was 0.8 mm. MRI was performed in axial and coronal plane with T2-weighted fast spin-echo (FSE) sequences, un-enhanced and contrast-enhanced T1-weighted spin-echo (SE) sequences, and coronal T1-weighted SE sequences with fat suppression and with 3D T1-weighted gradient-echo (GE) contrast-enhanced sequences in axial plane. The 3D T1-weighted GE sequence had a slice thickness of 1 mm. Image data sets of CT and 3D T1-weighted GE sequences were merged utilizing a workstation to create CT-MR fusion images. MDCT and MR images were separately used to depict and characterize lesions. The fusion images were utilized for interventional planning and intraoperative image guidance. The intraoperative accuracy of the navigation unit was measured, defined as the deviation between the same landmark in the navigation image and the patient. Results: Tumorous lesions of bone and soft tissue were well delineated and characterized by CT and MR images. The images played a crucial role in the differentiation of benign and malignant pathologies, which consisted of 13 benign and 2 malignant tumors. The CT-MR fusion images supported the surgeon in preoperative planning and improved surgical performance. The mean intraoperative accuracy of the navigation system was 1.25 mm. Conclusion: CT and MRI are essential in the preoperative work up of temporal bone tumors. CT-MR image data fusion presents an accurate tool for planning the correct surgical procedure and is a

  15. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of)

    1994-11-15

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings.

  16. Diagnosis of temporal bone diseases using three-dimensional images with multislice CT

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, Yoshihiro; Togami, Taro; Murota, Makiko; Fukunaga, Kotaro; Hino, Ichiro; Sato, Katashi; Ohkawa, Motoomi [Kagawa Medical Univ., Miki (Japan)

    2001-08-01

    We evaluated the usefulness of three-dimensional images with multislice CT in the temporal bone diseases. Fifty-nine cases (26 with medial otitis, 8 choresteatoma, 10 congenital malformation, 3 high jugular bulb, 2 otosclerosis, and 10 others) were included in this study. In the ossicular and inner ear lesions, oblique multiplanar images of the long axis of each ossicle was useful the detection of abnormality. Structural deformity of ossicles and bony labyrinth were clearly delineated by surface rendering images. (author)

  17. CT diagnosis and differential diagnosis of otodystrophic lesions of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    D' Archambeau, O.; Parizel, P.M.; Schepper, A.M. De (Antwerp University Hospital (Belgium). Department of Radiology); Koekelkoren, E.; Van De Heyning, P. (Antwerp University Hospital (Belgium). Department of E.N.T.)

    The purpose of this study was to assess the diagnostic and differential diagnostic value of high-resolution computed tomography in the evaluation of temporal-bone dystrophies. The study group included 55 patients with osseous abnormalities of the temporal bone in general, and the labyrinthine capsule in particular. In 27 patients the CT scan revealed evidence of otodystrophic lesions. The CT findings in patients with otosclerosis (21 patients), osteogenesis imperfecta (two patients), fibrous dysplasia (one patient). Paget's disease (one patient) and osteoporosis (two patients) are described. The CT scans of 17 patients revealed secondary osseous lesions due to metastasis (five patients), post-inflammatory changes (10 patients) or labyrinthitis ossificans (two patients). Normal variants and congenital mineralization defects were diagnosed in nine patients, Down's syndrome in two. Our results indicate the importance of high-resolution computed tomography as the primary imaging modality in evaluating osseous lesions of the temporal bone and labyrinth. (author). 14 refs.; 13 figs; 2 tabs.

  18. 3D-CT of the temporal bone area with high-speed processing

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Taku [Nagoya Univ. (Japan). Branch Hospital

    1994-12-01

    Three-dimentional (3D)-CT was introduced to represent abnormal findings in the temporal bone area utilizing a SOMATOM DRH CT scanner with accessory 3D reconstruction software and an exclusive high-speed 3D processing system, VOXEL FLINGER. In a patient with eosinophilic granuloma, a defect in the squamous part of the temporal bone was demonstrated suggesting exposure of the dura mater during surgery. In a patient with a normal ear, well-developed mastoid cavity, a part of the handle and the head of the malleus, the incudomalleal joint, the short limb, body and a part of the long limb of the incus and the round window niche were demonstrated. In a case of chronic otitis media, poorly developed mastoid cavity and a possible defect of the tip of the long limb of the incus were demonstrated, in contrast to the patient with the normal ear. 3D-CT yields objective and solid images which are useful for diagnosis, treatment planning and explanation of the pathology to patients and their family. To obtain convincing 3D images, physicians themselves have to choose exact rotation angles. It is not adequate to reconstruct original CT data using a CT computer with accessory 3D software whose processing capability is not good enough for this purpose. The conclusion is as follows: (1) it is necessary and effective to transfer original CT data into the memory of the exclusive high-speed 3D processing system and (2) process the data by the voxel memory method to establish a clinically valuable 3D-CT imaging system. (author).

  19. Vascular anomalies, sutures and small canals of the temporal bone on axial CT

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, Sabrina [Department of Diagnostic Radiology, University of Halle, E. Grube Str. 40, 06097 Halle (Germany)]. E-mail: sabrina.koesling@medizin.uni-halle.de; Kunkel, Petra [Department of Diagnostic Radiology, University of Leipzig (Germany); Schul, Thomas [Department of Diagnostic Radiology, University of Leipzig (Germany)

    2005-06-01

    Purpose: Subtle bony structures, small canals and fine sutures cause sometimes problems in the analysis of CTs of the temporal bone. The aim of this study was: to analyze the visibility of subtle structures and to estimate the incidence of vascular anomalies. Patients and method: We retrospectively analyzed axial scans of 223 high-resolution CTs of the temporal bone obtained as single slice or spiral CT with 1 mm slice thickness. All CTs had clinical indications. Two experienced radiologists studied CTs regarding the visibility of the fine sutures, fissures and small canals and the occurrence of vascular anomalies. Results: The following structures were seen commonly: sphenosquamosal suture (76%), arcuate artery canal (93%), vestibular aqueduct (89%), mastoid emissary vein (82%), singular canal (56%). Not so commonly were observed: tympanosquamosal suture (31%), mastoid canaliculus (28%), lateral sigmoid sinus (28%), petrotympanic fissure (24%), tympanomastoid suture (10%). Seldom we identified: the inferior tympanic canaliculus (6%), high jugular bulb (6%), anterior sigmoid sinus (5%), dehiscent internal carotid artery canal (2%), persistent petrosquamosal sinus (1%), dehiscent jugular bulb (1%). Persistent stapedial artery, aberrant internal carotid artery, dehiscent jugular bulb, high jugular bulb with diverticulum, anterior and dehiscent sigmoid sinus were detected in below 1% of the analyzed temporal bones. The frequency of asymmetry of the jugular foramen, which varied between 3% and 42%, depended on different criterions of size. Conclusion: A profound knowledge of normal anatomy and anomalies of the temporal bone avoids misinterpretation as pathological lesions and iatrogenic bleedings.

  20. Congenital external auditory canal atresia and stenosis: temporal bone CT findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hoon; Kim, Bum Soo; Jung, So Lyung; Kim, Young Joo; Chun, Ho Jong; Choi, Kyu Ho; Park, Shi Nae [College of Medicine, Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2002-04-01

    To determine the computed tomographic (CT) findings of atresia and stenosis of the external auditory canal (EAC), and to describe associated abnormalities in surrounding structures. We retrospectively reviewed the axial and coronal CT images of the temporal bone in 15 patients (M:F=8:7;mean age, 15.8 years) with 16 cases of EAC atresia (unilateral n=11, bilateral n=1) and EAC stenosis (unilateral n=3). Associated abnormalities of the EAC, tympanic cavity, ossicles, mastoid air cells, eustachian tube, facial nerve course, mandibular condyle and condylar fossa, sigmoid sinus and jugular bulb, and the base of the middle cranial fossa were evaluated. Thirteen cases of bony EAC atresia (one bilateral), with an atretic bony plate, were noted, and one case of unilateral membranous atresia, in which a soft tissue the EAC. A unilateral lesion occurred more frequently on the right temporal bone (n=8, 73%). Associated abnormalities included a small tympanic cavity (n=8, 62%), decreased mastoid pneumatization (n=8, 62%), displacement of the mandibular condyle and the posterior wall of the condylar fossa (n=7, 54%), dilatation of the Eustachian tube (n=7, 54%), and inferior displacement of the temporal fossa base (n=8, 62%). Abnormalities of ossicles were noted in the malleolus (n=12, 92%), incus (n=10, 77%) and stapes (n=6, 46%). The course of the facial nerve was abnormal in four cases, and abnormality of the auditory canal was noted in one. Among three cases of EAC stenosis, ossicular aplasia was observed in one, and in another the location of the mandibular condyle and condylar fossa was abnormal. In the remaining case there was no associated abnormality. Atresia of the EAC is frequently accompanied by abnormalities of the middle ear cavity, ossicles, and adjacent structures other than the inner ear. For patients with atresia and stenosis of this canal, CT of the temporal bone is essentially helpful in evaluating these associated abnormalities.

  1. CT findings of the temporal bone in CHARGE syndrome : aspects of importance in cochlear implant surgery

    NARCIS (Netherlands)

    Vesseur, A. C.; Verbist, B. M.; Westerlaan, H. E.; Kloostra, F. J. J.; Admiraal, R. J. C.; van Ravenswaaij-Arts, C. M. A.; Free, R. H.; Mylanus, E. A. M.

    2016-01-01

    To provide an overview of anomalies of the temporal bone in CHARGE syndrome relevant to cochlear implantation (CI), anatomical structures of the temporal bone and the respective genotypes were analysed. In this retrospective study, 42 CTs of the temporal bone of 42 patients with CHARGE syndrome were

  2. Semicircular canal dehiscence: Frequency and distribution on temporal bone CT and its relationship with the clinical outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Elmali, Muzaffer, E-mail: muzafel@yahoo.com.tr [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Polat, Ahmet Veysel, E-mail: veyselp@hotmail.com [Department of Radiology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Kucuk, Harun, E-mail: hardrmd@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Atmaca, Sinan, E-mail: sinanatmaca@yahoo.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey); Aksoy, Ahmet, E-mail: toxocara47@hotmail.com [Department of Otorhinolaryngology, Ondokuz Mayis University, Faculty of Medicine, Samsun (Turkey)

    2013-10-01

    Purpose: In this study, we aimed to investigate the frequency of SCD and its distribution and relationship with clinical outcomes on thin-section CT of the temporal bone. Materials and methods: Digital temporal bone CT images of 850 consecutive patients (1700 temporal bone CTs, 5100 SCs) who presented with a range of complaints such as vertigo, deafness, ear pain, fullness, and discharge between January 2008 and December 2011 were re-evaluated. Axial and oblique coronal reconstruction images of the temporal bone were made with a reconstruction thickness of 0.5 mm. Additionally, superior SC was evaluated in two perpendicular planes. Results: Out of 850 patients, 70 had completely normal temporal bone CT. Ninety-three patients had at least one SCD. In the temporal bone-based evaluation, 119 (26 bilateral, 67 unilateral) of 1700 temporal bones (7%) showed dehiscence. The SC-based evaluation revealed 125 SCD (2.5%) in 5100 SCs. The total number and rates of SCD were as follows: superior 103 (82.4%), posterior 13 (10.4%), and lateral nine (7.2%). Twenty of the 93 patients with SCD (21.5%) revealed no other findings on their temporal bone CTs. We determined a significant correlation between vestibular complaints, conductive hearing loss and SCD but there was no correlation between mixed, sensorineural hearing loss and SCD. Conclusion: We determined the frequency of SCD in 11% of patients and 7% of temporal bones. With regards to the distribution, the superior SC showed the highest dehiscence rate (82.4%). We found a significant correlation between vestibular symptoms, conductive hearing loss and SCD.

  3. Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases.

    Science.gov (United States)

    Toriihara, Akira; Tsunoda, Atsunobu; Takemoto, Akira; Kubota, Kazunori; Machida, Youichi; Tateishi, Ukihide

    2015-01-01

    Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT), magnetic resonance imaging (MRI), and dual-time-point (18)F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET)/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the tumor showed low signal intensity on T2-weighted MRI images and non-uniform enhancement on gadolinium contrast-enhanced T1-weighted images. No increase in signal intensity was noted in diffusion-weighted images. Dual-time-point PET/CT showed markedly elevated (18)F-FDG uptake, which increased from the early to delayed phase. Nevertheless, immunohistochemical analysis of the resected tumor tissue revealed weak expression of glucose transporter-1 and hexokinase II in both tumors. Temporal bone tumors, showing markedly elevated (18)F-FDG uptake, which increases from the early to delayed phase on PET/CT images, may be diagnosed as malignant bone tumors. Therefore, the differential diagnosis should include chondroblastoma in combination with its characteristic findings on CT and MRI.

  4. Dual-time-point FDG-PET/CT Imaging of Temporal Bone Chondroblastoma: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Akira Toriihara

    2015-07-01

    Full Text Available Temporal bone chondroblastoma is an extremely rare benign bone tumor. We encountered two cases showing similar imaging findings on computed tomography (CT, magnetic resonance imaging (MRI, and dual-time-point 18F-fluorodeoxyglucose (18F-FDG positron emission tomography (PET/CT. In both cases, CT images revealed temporal bone defects and sclerotic changes around the tumor. Most parts of the tumor showed low signal intensity on T2- weighted MRI images and non-uniform enhancement on gadolinium contrast-enhanced T1-weighted images. No increase in signal intensity was noted in diffusion-weighted images. Dual-time-point PET/CT showed markedly elevated 18F-FDG uptake, which increased from the early to delayed phase. Nevertheless, immunohistochemical analysis of the resected tumor tissue revealed weak expression of glucose transporter-1 and hexokinase II in both tumors. Temporal bone tumors, showing markedly elevated 18F-FDG uptake, which increases from the early to delayed phase on PET/CT images, may be diagnosed as malignant bone tumors. Therefore, the differential diagnosis should include chondroblastoma in combination with its characteristic findings on CT and MRI.

  5. Improving Depiction of Temporal Bone Anatomy With Low-Radiation Dose CT by an Integrated Circuit Detector in Pediatric Patients

    Science.gov (United States)

    He, Jingzhen; Zu, Yuliang; Wang, Qing; Ma, Xiangxing

    2014-01-01

    Abstract The purpose of this study was to determine the performance of low-dose computed tomography (CT) scanning with integrated circuit (IC) detector in defining fine structures of temporal bone in children by comparing with the conventional detector. The study was performed with the approval of our institutional review board and the patients’ anonymity was maintained. A total of 86 children  0.05). The low-dose CT images acquired with the IC detector provide better depiction of fine osseous structures of temporal bone than that with the conventional DC detector. PMID:25526489

  6. Chondroblastoma of temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Tanohta, K.; Noda, M.; Katoh, H.; Okazaki, A.; Sugiyama, S.; Maehara, T.; Onishi, S.; Tanida, T.

    1986-07-01

    The case of a 55-year-old female with chondroblastoma arising from the left temporal bone is presented. Although 10 cases of temporal chondroblastoma have been reported, this is the first in which plain radiography, pluridirectional tomography, computed tomography (CT) and angiography were performed. We discuss the clinical and radiological aspects of this rare tumor.

  7. Clinically relevant human temporal bone measurements using novel high-resolution cone-beam CT

    Directory of Open Access Journals (Sweden)

    Jing Zou

    2017-03-01

    Conclusion: This novel high-resolution CBCT system has potentially broad applications in the diagnosis of inner ear disease and in monitoring associated pathological changes, surgical planning, navigation for the ear surgery, and temporal bone training.

  8. A three-dimensional reconstruction of the temporal bone by the helical scanning CT and its clinical application

    Energy Technology Data Exchange (ETDEWEB)

    Yonekawa, Hiroyuki; Ohashi, Masami; Miyashita, Souji; Gotoh, Mizuho; Nemoto, Satohiko; Kikuchi, Hideki (Azabu Triology Hospital, Sapporo (Japan)); Sakai, Noboru; Inuyama, Yukio

    1993-09-01

    The current availability of 3 dimensional (3-D) imaging from Computed Tomography (CT) has yielded new anatomical information and pre- and postoperative evaluations. However, little discussion as to the 3-D structural image of the temporal bone has been reported because conventional CT does provide sufficient data to produce such images. The helical scanning CT gathers continuous and multiple slice image data since it consists of an X-ray tube that continuously rotates around the patient while the patient moves continuously into the CT scanner. Thus, application of the helical scanning CT has made it possible to reconstruct 3-D images of the minute and complicated structure of the temporal bone. We evaluated 3-D images from 9 typical cases, examined from February to October 1992. As a result, we found that the 3-D images reconstructed with this system are useful for evaluation of the postoperative state of tympanoplasty, the diagnosis of anomalies of the bony labyrinth, and examining the extent of bone destruction induced by trauma, cholesteatoma, etc. (author).

  9. Investigation of the vestibular aqueduct and the cochlear aqueduct by temporal bone CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Ryuichi; Kamei, Tamio; Ito, Fumihide (Gunma Univ., Maebashi (Japan). School of Medicine)

    1984-02-01

    The visualization of the vestibular aqueduct and the cochlear aqueduct was investigated by temporal bone CT scan. The vestibular aqueduct was visualized in horizontal CT sections of 70.0% of normal ears, 61.5% of ears with chronic otitis media, 58.3% of ears with combined hearing impairment, 66.7% of ears in cases of sudden deafness, 70.8% of ears of patients with sensorineural hearing impairment without sudden deafness, 71.4% of cases of vertigo without hearing impairment and 12.5% of both diseased and contralateral ears of patients with Meniere's disease. Only in Meniere's disease was the vestibular aqueduct less visible in the diseased than in the normal ear (P<0.01). The cochlear aqueduct was visible in coronal sections of 50.0% of normal ears, 76.9% of those with chronic otitis media, 58.3% of those with combined hearing impairment, 66.7% of those with sudden deafness 41.7% of those with sensorineural hearing impairment without sudden deafness, 50.0% of the diseased ears of patients with Meniere's disease, 37.5% of the contralateral ears of those with Meniere's disease and 64.3% of those with vertigo without hearing impairment. Although the cochlear aqueduct was thus highly demonstrable in patients with chronic otitis media or sudden deafness, the difference between the percentage of visualization in these diseased and in normal ears was not statistically significant.

  10. CT VIRTUAL ENDOSCOPY IN ASSESSING OSSICULAR CHAIN DISRUPTION CSUSED BY TEMPORAL BONE FRACTURE AND EAR TRAUMA

    Institute of Scientific and Technical Information of China (English)

    JIANG Lixin; XIAO Zhiwen

    2013-01-01

    Objective To explore the value of computed tomography virtual endoscopy (VE) in assessing ossicular chain disruption in temporal bone fracture and ear trauma with intact tympanum. Methods High resolution spiral computerized tomography (CT) was completed in 35 cases of temporal bone fracture and 5 cases of tympanum trauma, all with intact or healed tympanum. Three-dimensional reconstruction was completed us-ing a virtual endoscopy software. Audiological tests were conducted in all patients and evaluation of facial nerve injury in patients with facial paralysis. Patients with mild conductive deafness, ossicular chain sublux-ation on VE, and no facial paralysis were treated conservatively for 4-12 weeks with repeated hearing evalu-ation; those with facial paralysis underwent surgery if no recovery after 4-8 weeks of conservative treat-ment. Patients with moderate to severe conductive hearing loss or mixed hearing loss, incus long process fracture or dislocation on VE and facial paralysis, underwent ossicular chain reconstruction and facial nerve decompression after conservative treatment for 4-8 weeks, or exploratory tympanotomy only if no facial pa-ralysis. VE, audiological tests and facial nerve function tests were repeated in 3-6 months after surgery. Re-sults Of the 6 cases with mild conductive hearing loss, ossicular chain subluxation and no facial paralysis, 3 recovered to normal hearing spontaneously and 3 showed no significant improvement, after 4-12 weeks of conservative treatment. After conservative treatment for 4-8 weeks, 3 of the 12 cases with mild conductive deafness, ossicular chain dislocation on VE and facial paralysis recovered to normal hearing and House-Brackmann (HB) grade I facial function from HB grade II ,4 showed facial function recovery to HB grade I (n=2) or II (n=2) from HB grade III but no hearing recovery, and 5 gained no recovery and went on to receive exploratory tympanotomy and facial nerve decompression. The 11 cases with moderate to

  11. Differential diagnosis between chronic otitis media with and without cholesteatoma by temporal bone CT: focus on bone change and mass effect

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Cheol Kyu; Park, Dong Woo; Seong, Jin Yong; Lee, Kak Soo; Park Choong Ki; Lee, Seung Ro; Hahm, Chang Kok [College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    2000-01-01

    In order to determine specific differences, we compared the temporal bone CT findings of chronic otitis media (COM) with and without cholesteatoma, focusing on bone change. Between 1997 and 1998, 82 patients (84 cases) underwent temporal bone CT and were shown to have COM, with or without cholesteatoma after mastoidectomy and tympanoplasty. There were 36 cases of COM with cholesteatoma (26 patients, M:F =3D 11:15; age range, 16-61 (mean, 36,2) years), and 58 cases without chlesteatoma (56 patients, M:F =3D 25:31, age range, 15-61 (mean, 36.2) years). The findings of temporal bone CT were analysed at the point of bony changes including erosion and medial displacement of ossicles (malleus, incus, and stapes), erosion or destruction of the scutum, tegmen, facial canal, and lateral semicircular canal, and ballooning of the tympanic cavity and mastoid antrum. In addition, the soft tissue changes seen on temporal bone CT were analyzed at the site of lateral bulging of soft tissue in Prussak's space, perforation of the pars flaccida, tympanic membrane retraction, and tympanosclerosis. We retrospectively compared the findings of temporal bone CT with the surgical findings, and to assess statistical significance, the Chi-square test was used. Bone erosion or destruction was seen in 36.2% of COM cases without cholesteatoma, and in 96.2% of cases with cholesteatoma. Comparing COM with and without cholesteatoma, the erosion of ossicles including the malleus (81%, 24%), incus (88%, 14%), stapes (58%, 10%), scutum (88%, 10%), facial canal (8%, 0%), and lateral semicircular canal (8%, 0%), was more common in COM with cholesteatoma (p-value less than 0.05), with the exception of erosion of the tegmen (8%, 3%). Other bony changes including medial displacement of ossicles (27%, 3%), ballooning of tympanic cavity and mastoid antrum (96%, 16%), and the soft tissue changes including lateral bulging of soft tissue in Prussak's space (58%, 14%) and perforation of the pars

  12. Temporal bone CT findings of tuberculous otitis media : comparison with chronic otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Jeong A; Rho, Myung Ho; Kim, Young Min; Lee, Ho Seung; Choi, Pil Yeob; Seong, Young Soon; Kwon, Jae Soo; Lee, Sang Wook [Masan Samsung Hospital, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of); Jung, Keon Sik [Pohang Sunrin Hospital, Pohang (Korea, Republic of)

    1999-06-01

    To compare the differential findings of tuberculous otitis media(TOM) with those of chronic sup purative otitis media with or without cholesteatoma, as seen on high resolution temporal bone CT. We retrospectively reviewed 14 cases of TOM, 30 cases of chronic suppurative otitis media(CSOM), and 30 cases of chronic otitis media with cholesteatoma(Chole). All had been pathologically confirmed. We evaluated the preservation of mastoid cells without sclerotic change, the location and extension of soft tissue to the external auditary canal, and erosion of ossicles, the tegmen tympani, scutum, bony labyrinth, facial nerve canal and sigmoid sinus, and the presence of intracranial complications. Soft tissue in the mastoid antrum was seen in all cases of TOM(100%), 29 cases of CSOM(96.7%), and 26 cases of Chole(86.7%). In contrast, the soft tissue in the entire middle ear cavity was noted in 13 cases of TOM(92.8%), 7 cases of CSOM(23.3%), and 12 cases of Chole(40%). Soft tissue extended to the superior aspect of the external auditory canal in 4 cases of TOM (28.6%) and 5 cases of Chole (16.7%). Mastoid air cells were seen in 9 cases of TOM (64.3%), 4 cases of CSOM (13.3%), and 3 cases of Chole(10%). Ossicular erosion was noted in 6 cases of TOM (42.9%), 12 cases of CSOM (40%), and 26 cases of Chole(86.7%), while in one case of TOM (7.1%), 5 cases of CSOM (16.7%), and 15 cases of Chole(50%) there was erosion of the scutum. In one case of TOM, follow-up CT study after 9 months of antituberculous medication without surgery revealed complete clearing of previously noted soft tissue in the middle ear cavity. Specific CT findings of TOM were not seen, but if there were findings of soft tissue in the entire middle ear cavity, soft tissue extension to the external auditory canal, preservation of mastoid air cells without sclerotic change, and intact scutum, TOM may be differentiated from other chronic otitis media.

  13. Cholesterol granuloma of temporal bone: CT and MR findings. Granulomas colesterinicos del hueso temporal: hallazgos por TC y RM

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Jauriguizuria, J.C.; Ferrero Collado, A.; Ereo Ealo, M.J.; Grande Icaran, D.

    1994-01-01

    Three cases of cholesterol granuloma of the left temporal bone are presented, two located in the petrous apex and the other at the otomastoid level. One of the patients had a history of mastoid surgery and the other surgery of the bone ridge. The three cases were confirmed histologically following surgical resection. The etiopathogenesis of the lesion is discussed, as are the clinical, histological and radiological features, with a broad description of the computed tomography and magnetic resonance findings. The differential diagnosis is also dealt with. (Author)

  14. Nerve canals at the fundus of the internal auditory canal on high-resolution temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Yoon Ha; Youn, Eun Kyung; Kim, Seung Chul [Sungkyunkwan Univ., School of Medicine, Seoul (Korea, Republic of)

    2001-12-01

    To identify and evaluate the normal anatomy of nerve canals in the fundus of the internal auditory canal which can be visualized on high-resolution temporal bone CT. We retrospectively reviewed high-resolution (1 mm thickness and interval contiguous scan) temporal bone CT images of 253 ears in 150 patients who had not suffered trauma or undergone surgery. Those with a history of uncomplicated inflammatory disease were included, but those with symptoms of vertigo, sensorineural hearing loss, or facial nerve palsy were excluded. Three radiologists determined the detectability and location of canals for the labyrinthine segment of the facial, superior vestibular and cochlear nerve, and the saccular branch and posterior ampullary nerve of the inferior vestibular nerve. Five bony canals in the fundus of the internal auditory canal were identified as nerve canals. Four canals were identified on axial CT images in 100% of cases; the so-called singular canal was identified in only 68%. On coronal CT images, canals for the labyrinthine segment of the facial and superior vestibular nerve were seen in 100% of cases, but those for the cochlear nerve, the saccular branch of the inferior vestibular nerve, and the singular canal were seen in 90.1%, 87.4% and 78% of cases, respectiveIy. In all detectable cases, the canal for the labyrinthine segment of the facial nerve was revealed as one which traversed anterolateralIy, from the anterosuperior portion of the fundus of the internal auditory canal. The canal for the cochlear nerve was located just below that for the labyrinthine segment of the facial nerve, while that canal for the superior vestibular nerve was seen at the posterior aspect of these two canals. The canal for the saccular branch of the inferior vestibular nerve was located just below the canal for the superior vestibular nerve, and that for the posterior ampullary nerve, the so-called singular canal, ran laterally or posteolateralIy from the posteroinferior aspect of

  15. Improving depiction of temporal bone anatomy with low-radiation dose CT by an integrated circuit detector in pediatric patients: a preliminary study.

    Science.gov (United States)

    He, Jingzhen; Zu, Yuliang; Wang, Qing; Ma, Xiangxing

    2014-12-01

    The purpose of this study was to determine the performance of low-dose computed tomography (CT) scanning with integrated circuit (IC) detector in defining fine structures of temporal bone in children by comparing with the conventional detector. The study was performed with the approval of our institutional review board and the patients' anonymity was maintained. A total of 86 children0.05). The low-dose CT images acquired with the IC detector provide better depiction of fine osseous structures of temporal bone than that with the conventional DC detector.

  16. Significance of temporal bone CT scan for exposure of the facial canal and the lateral semicircular canal in cholesteatoma

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ki Joon; Kim, Dong Jin; Kim, Myung Soon; Kim, Young Ju; Kweon, Joon [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    1991-09-15

    By reviewing retrospectively the HRCT findings in 130 surgically proven cases of chronic otitis media with cholesteatoma, we estimated the sensitivity, specificity, and positive predictability of the HRCT compared to surgical findings. For exposure of the facial canal, the sensitivity, specificity, and positive predictability was 59.7%, 84.9%, and 85.2% respectively. For exposure of the lateral semicircular canal, the sensitivity was 80.6%, the specificity 99.0%, and the positive predictability 96.2%. Conclusively, the diagnostic accuracy of preoperative temporal bone CT regarding the state of the lateral semicircular canal seems to be highly reliable. Gross invasion of the facial canal can be usually detected. However, relatively low sensitivity suggests that evaluation of the ultra-thin structures of the tympanic segment is often problematic.

  17. A novel framework for the temporal analysis of bone mineral density in metastatic lesions using CT images of the femur

    Science.gov (United States)

    Knoop, Tom H.; Derikx, Loes C.; Verdonschot, Nico; Slump, Cornelis H.

    2015-03-01

    In the progressive stages of cancer, metastatic lesions in often develop in the femur. The accompanying pain and risk of fracture dramatically affect the quality of life of the patient. Radiotherapy is often administered as palliative treatment to relieve pain and restore the bone around the lesion. It is thought to affect the bone mineralization of the treated region, but the quantitative relation between radiation dose and femur remineralization remains unclear. A new framework for the longitudinal analysis of CT-scans of patients receiving radiotherapy is presented to investigate this relationship. The implemented framework is capable of automatic calibration of Hounsfield Units to calcium equivalent values and the estimation of a prediction interval per scan. Other features of the framework are temporal registration of femurs using elastix, transformation of arbitrary Regions Of Interests (ROI), and extraction of metrics for analysis. Build in Matlab, the modular approach aids easy adaptation to the pertinent questions in the explorative phase of the research. For validation purposes, an in-vitro model consisting of a human cadaver femur with a milled hole in the intertrochanteric region was used, representing a femur with a metastatic lesion. The hole was incrementally stacked with plates of PMMA bone cement with variable radiopaqueness. Using a Kolmogorov-Smirnov (KS) test, changes in density distribution due to an increase of the calcium concentration could be discriminated. In a 21 cm3 ROI, changes in 8% of the volume from 888 ± 57mg • ml-1 to 1000 ± 80mg • ml-1 could be statistically proven using the proposed framework. In conclusion, the newly developed framework proved to be a useful and flexible tool for the analysis of longitudinal CT data.

  18. Evaluation of temporal bone pneumatization on high resolution CT (HRCT) measurements of the temporal bone in normal and otitis media group and their correlation to measurements of internal auditory meatus, vestibular or cochlear aqueduct

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Miyako

    1988-07-01

    High resolution CT axial scans were made at the three levels of the temoral bone 91 cases. These cases consisted of 109 sides of normal pneumatization (NR group) and 73 of poor pneumatization resulted by chronic otitis (OM group). NR group included sensorineural hearing loss cases and/or sudden deafness on the side. Three levels of continuous slicing were chosen at the internal auditory meatus, the vestibular and the cochlear aqueduct, respectively. In each slice two sagittal and two horizontal measurements were done on the outer contour of the temporal bone. At the proper level, diameter as well as length of the internal acoustic meatus, the vestibular or the cochlear aqueduct were measured. Measurements of the temporal bone showed statistically significant difference between NR and OM groups. Correlation of both diameter and length of the internal auditory meatus to the temporal bone measurements were statistically significant. Neither of measurements on the vestibular or the cochlear aqueduct showed any significant correlation to that of the temporal bone.

  19. High-resolution CT of temporal bone trauma: review of 38 cases; L'apport du scanner dans les traumatismes du rocher: a propos de 38 cas

    Energy Technology Data Exchange (ETDEWEB)

    Hiroual, M.R.; Zougarhi, A.; Cherif Idrissi El Ganouni, N.; Essadki, O.; Ousehal, A. [CHU Mohamed 6, Service de Radiologie, Marrakech (Morocco); Tijani Adil, O.; Maliki, O.; Aderdour, L.; Raji, A. [CHU Mohamed 6, Service d' ORL, Marrakech (Morocco)

    2010-01-15

    Purpose Temporal bone trauma is frequent but difficult to assess due to the diversity of clinical presentations and complex anatomy. We have sought to assess the different types of fractures and complications on high-resolution CT. Materials and methods Descriptive retrospective study over a 24 month period performed in the ENT radiology section of the Mohammed 6 university medical center in Marrakech. A total of 38 cases of temporal bone trauma were reviewed. All patients underwent ENT evaluation and high-resolution CT of the temporal bone using 1 mm axial and coronal sections. Results Mean patient age was 33 years (range: 14-55 years) with male predominance (sex ratio: 36/2). Clinical symptoms were mainly otorrhagia and conductive hearing loss. Oblique extra-labyrinthine fractures were most frequent. Two cases of pneumo-labyrinth were noted. Management was conservative in most cases with deafness in 3 cases. Conclusion High-resolution CT of the temporal bone provides accurate depiction of lesions explaining the clinical symptoms and helps guide management. MRI is complimentary to further assess the labyrinth and VII-VIII nerve complex. (author)

  20. Visualization of subtle temporal bone structures. Comparison of cone beam CT and MDCT; Darstellung subtiler Schlaefenbeinstrukturen. In-vivo-Vergleich digitale Volumentomographie vs. Multidetektor-CT

    Energy Technology Data Exchange (ETDEWEB)

    Pein, M.K.; Plontke, S.K. [Universitaetsklinikum Halle (Saale), Universitaetsklinik und Poliklinik fuer HNO-Heilkunde, Kopf- und Halschirurgie, Halle (Saale) (Germany); Brandt, S.; Koesling, S. [Universitaetsklinikum Halle (Saale), Universitaetsklinik und Poliklinik fuer Diagnostische Radiologie, Halle (Saale) (Germany)

    2014-03-15

    The purpose of this study was to compare the visualization of subtle, non-pathological temporal bone structures on cone beam computed tomography (CBCT) and multi-detector computed tomography (MDCT) in vivo. Temporal bone studies of images from 38 patients archived in the picture archiving and communication system (PACS) were analyzed (slice thickness MDCT 0.6 mm and CBCT 0.125 mm) of which 23 were imaged by MDCT and 15 by CBCT using optimized standard protocols. Inclusion criteria were normal radiological findings, absence of previous surgery and anatomical variants. Images were evaluated blind by three trained observers. Using a five-point scale the visualization of ten subtle structures of the temporal bone was analyzed. Subtle middle ear structures showed a tendency to be more easily distinguishable by CBCT with significantly better visualization of the tendon of the stapedius muscle and the crura of the stapes on CBCT (p = 0.003 and p = 0.033, respectively). In contrast, inner ear components, such as the osseus spiral lamina and the modiolus tended to be better detectable on MDCT, showing significant differences for the osseous spiral lamina (p = 0.001). The interrater reliability was 0.73 (Cohen's kappa coefficient) and intraobserver reliability was 0.89. The use of CBCT and MDCT allows equivalent and excellent imaging results if optimized protocols are chosen. With both imaging techniques subtle temporal bone structures could be visualized with a similar degree of definition. In vivo differences do not seem to be as large as suggested in several previous studies. (orig.) [German] Vergleich der Identifizierbarkeit subtiler Schlaefenbeinstrukturen in der digitalen Volumentomographie (DVT) und Multidetektor-CT (MDCT) in vivo. Analysiert wurden 38 im PACS (Picture Archiving and Communication System) duennschichtig gespeicherte Schlaefenbeinuntersuchungen (23 MDCTs, Schichtdicke 0,6 mm sowie 15 DVTs, Schichtdicke 0,125 mm). Einschlusskriterium war eine

  1. 3D curved multiplanar cone beam CT reconstruction for intracochlear position assessment of straight electrodes array. A temporal bone and clinical study.

    Science.gov (United States)

    De Seta, D; Mancini, P; Russo, F Y; Torres, R; Mosnier, I; Bensimon, J L; De Seta, E; Heymann, D; Sterkers, O; Bernardeschi, D; Nguyen, Y

    2016-12-01

    A retrospective review of post-op cone beam CT (CBCT) of 8 adult patients and 14 fresh temporal bones that underwent cochlear implantation with straight flexible electrodes array was performed to determine if the position of a long and flexible electrodes array within the cochlear scalae could be reliably assessed with CBCT. An oto-radiologist and two otologists examined the images and assessed the electrodes position. The temporal bone specimens underwent histological analysis for confirm the exact position. The position of the electrodes was rated as scala tympani, scala vestibule, or intermediate position for the electrodes at 180°, 360° and for the apical electrode. In the patient group, for the electrodes at 180° all observers agreed for scala tympani position except for 1 evaluation, while a discrepancy in 3 patients both for the 360° and for the apical electrode assessment were found. In five temporal bones the evaluations were in discrepancy for the 180° electrode, while at 360° a disagreement between raters on the scalar positioning was seen in six temporal bones. A higher discrepancy between was found in assessment of the scalar position of the apical electrode (average pairwise agreement 45.4%, Fleiss k = 0.13). A good concordance was found between the histological results and the consensus between raters for the electrodes in the basal turn, while low agreement (Cohen's k 0.31, pairwise agreement 50%) was found in the identification of the apical electrode position confirming the difficulty to correct identify the electrode position in the second cochlear turn in temporal bones. In conclusion, CBCT is a reliable radiologic exam to correctly evaluate the position of a lateral wall flexible array in implanted patients using the proposed imaging reconstruction method, while some artefacts impede exact evaluation of the position of the apical electrode in temporal bone and other radiological techniques should be preferred in ex vivo studies.

  2. Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

    Science.gov (United States)

    Meyer, Mathias; Haubenreisser, Holger; Raupach, Rainer; Schmidt, Bernhard; Lietzmann, Florian; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Schad, Lothar R; Schoenberg, Stefan O; Henzler, Thomas

    2015-01-01

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm(2) removes the necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50% • A smaller focal spot of 0.2 mm (2) significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear.

  3. SHEEP TEMPORAL BONE

    Directory of Open Access Journals (Sweden)

    Kesavan

    2016-03-01

    Full Text Available INTRODUCTION Human temporal bones are difficult to procure now a days due to various ethical issues. Sheep temporal bone is a good alternative due to morphological similarities, easy to procure and less cost. Many middle ear exercises can be done easily and handling of instruments is done in the procedures like myringoplasty, tympanoplasty, stapedotomy, facial nerve dissection and some middle ear implants. This is useful for resident training programme.

  4. Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Mathias; Haubenreisser, Holger; Schoenberg, Stefan O.; Henzler, Thomas [Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany); Raupach, Rainer; Schmidt, Bernhard; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas [Siemens Healthcare, Imaging and Therapy Division, Forchheim (Germany); Lietzmann, Florian; Schad, Lothar R. [Heidelberg University, Computer Assisted Clinical Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Mannheim (Germany)

    2015-01-15

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm{sup 2} removesthe necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63 %/39 % lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. (orig.)

  5. Virtual Temporal Bone Anatomy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Background The Visible Human Project(VHP) initiated by the U.S. National Library of Medicine has drawn much attention and interests from around the world. The Visible Chinese Human (VCH) project has started in China. The current study aims at acquiring a feasible virtual methodology for reconstructing the temporal bone of the Chinese population, which may provide an accurate 3-D model of important temporal bone structures that can be used in teaching and patient care for medical scientists and clinicians. Methods A series of sectional images of the temporal bone were generated from section slices of a female cadaver head. On each sectional image, SOIs (structures of interest) were segmented by carefully defining their contours and filling their areas with certain gray scale values. The processed volume data were then inducted into the 3D Slicer software(developed by the Surgical Planning Lab at Brigham and Women's Hospital and the MIT AI Lab) for resegmentation and generation of a set of tagged images of the SOIs. 3D surface models of SOIs were then reconstructed from these images. Results The temporal bone and structures in the temporal bone, including the tympanic cavity, mastoid cells, sigmoid sinus and internal carotid artery, were successfully reconstructed. The orientation of and spatial relationship among these structures were easily visualized in the reconstructed surface models. Conclusion The 3D Slicer software can be used for 3-dimensional visualization of anatomic structures in the temporal bone, which will greatly facilitate the advance of knowledge and techniques critical for studying and treating disorders involving the temporal bone.

  6. Temporal bone imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lemmerling, Marc [Algemeen Ziekenhuis Sint-Lucas, Gent (Belgium). Dept. of Radiology; Foer, Bert de (ed.) [Sint-Augustinus Ziekenhuis, Wilrijk (Belgium). Dept. of Radiology

    2015-04-01

    Complete overview of imaging of normal and diseased temporal bone. Straightforward structure to facilitate learning. Detailed consideration of newer imaging techniques, including the hot topic of diffusion-weighted imaging. Includes a chapter on anatomy that will be of great help to the novice interpreter of imaging findings. Excellent illustrations throughout. This book provides a complete overview of imaging of normal and diseased temporal bone. After description of indications for imaging and the cross-sectional imaging anatomy of the area, subsequent chapters address the various diseases and conditions that affect the temporal bone and are likely to be encountered regularly in clinical practice. The classic imaging methods are described and discussed in detail, and individual chapters are included on newer techniques such as functional imaging and diffusion-weighted imaging. There is also a strong focus on postoperative imaging. Throughout, imaging findings are documented with the aid of numerous informative, high-quality illustrations. Temporal Bone Imaging, with its straightforward structure based essentially on topography, will prove of immense value in daily practice.

  7. Chondroblastoma of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yuko; Murakami, Ryusuke; Toba, Masahiro; Ichikawa, Taro [Dept. of Radiology, Nippon Medical School, Tokyo (Japan); Kanazawa, Ryuzaburo; Sanno, Naoko; Shimura, Toshiro [Dept. of Neurosurgery, Nippon Medical School, Tokyo (Japan); Sawada, Namie; Hosone, Masaru [Dept. of Pathology, Nippon Medical School, Tokyo (Japan); Kumazaki, Tatsuo [Dept. of Radiology, Nippon Medical School, Tokyo (Japan)

    2001-12-01

    A rare case of chondroblastoma arising from the temporal bone that occurred in a 60-year-old woman is reported. The tumor appeared well demarcated and osteolytic on the radiographs. CT scan clearly depicted marginal and central calcification in the tumor. MR imaging demonstrated two components in the tumor: a solid component with predominantly low signal intensities on both T1- and T2-weighted sequences, and a multilocular cystic component with T1- and T2-elongation and fluid-fluid levels on the T2-weighted images. Postcontrast MR imaging revealed marked enhancement in the solid component and the septa of the cystic component. (orig.)

  8. Temporal Bone Localized Chondroblastoma.

    Science.gov (United States)

    Demirhan, Hasan; Acioğlu, Engin; Durna, Yusuf Muhammed; Yiğit, Özgür; Bozkurt, Erol Rüştü; Karagöz, Yeşim

    2015-11-01

    Chondroblastoma is a highly destructive tumor originating from immature cartilage cells. Although chondroblastoma is defined as a benign tumor, it may exhibit malign tumor behaviors such as invasion or metastasis on neighboring structures. Magnetic resonance (MR) image is a solid mass lesion, which included heterogeneous hypointense in T2A and heterogeneous minimal hyperintense in T1A with destructive expansile characteristics and millimetric calcifications. Temporal bone chondroblastomas may complicate the diagnosis because of their different histologic characteristics. Microscopically, chondroblastic cell nests and calcification of locally "chicken wire" type around the cells are observed. These tumors secrete s-100 and vimentin and are used for differential diagnosis. In this study, a temporal bone localized chondroblastoma case is presented.

  9. Virtual temporal bone

    Institute of Scientific and Technical Information of China (English)

    QIU Ming-guo; ZHANG Shao-xiang; LIU Zheng-jin; TAN Li-wen; WANG Yu-su; DENG Jun-hui; TANG Ze-sheng

    2002-01-01

    Objective:To provide the virtual model of the temporal bone for improving 3-dimension (3D) visualization of the inner ear. Methods: Plastination technique was used to make equidistant serial thin sections 1.0 mm in thickness. On SGI workstation, a Contours+Marching Cubes algorithm was selected to reconstruct the temporal bone and intratemporal structures in 3D, then to view the middle ear, inner ear, and intratemporal structures which imitate the scenes observed by the traditional endoscopy. Results: The virtual model of the temporal bone was successfully constructed, with all reconstructed structures being represented individually or jointly and being rotated continuously in any plane. Virtual endoscopy improved 3D visualization of the middle ear, inner ear, and intratemporal structures. Conclusion: The reconstructed model can be used for the medical students to rehearse or review the surgeries on this part and for the surgeons to develop a new approach for operation. Virtual otoscopy stands as a promising new visualization technique for elucidating the structure and relation of the middle ear, inner ear, and intratemporal structures.

  10. Sensorineural hearing loss: there is no correlation with isolated dysplasia of the lateral semi-circular canal on temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Tuvshinjargal, Dashjamts; Kamano, Hironori; Honda, Hiroshi (Dept. of Clinical Radiology, Graduate School of Medical Sciences, Kyushu Univ. Fukuoka (Japan)), email: tyoshiu@radiol.med.kyushu-u.ac.jp; Inoguchi, Takashi (Dept. of Otolaryngology, Kitakyushu Municipal Medical Center, Kitakyushu (Japan))

    2011-02-15

    Background: Inner ear malformations may cause sensorineural hearing loss (SNHL). However, the correlation between the small lateral semi-circular canal (LSCC) and SNHL is controversial. Purpose: To determine whether there is a correlation between the two using CT-based measurement. Material and Methods: We retrospectively reviewed the high-resolution CT images of the temporal bone obtained from consecutive patients. A total 136 ears of 68 patients (25 men and 43 women; age range 20-85 years, mean 49.8 years) were included in this study. Patients who were clinically suspected to have otosclerosis were also excluded. Two radiologists independently measured the width and cross-sectional area of the bony island of LSCC. We evaluated the correlation between LSCC bone island width or cross-sectional area and hearing level in all cases using Pearson correlation co-efficients. In addition, we compared hearing levels among the patient group with normal-sized LSCC (>=mean-SD), small LSCC (0.05). No significant difference in hearing levels were found among groups of the normal-sized, small and very small LSCC (P>0.05). Conclusion: We conclude that there is no correlation between isolated small LSCC and SNHL

  11. Ivory Osteoma Of Temporal Bone

    Directory of Open Access Journals (Sweden)

    Ravi Meher

    2006-03-01

    Full Text Available Osteomas are slow growing bony tumors common in fronto-ethmoid regions and rare in temporal bone. These are usually asymptomatic and require treatment mainly for cosmetic reasons. We describe a case of temporal bone osteoma in a female.

  12. Imaging of inflammatory and infectious diseases in the temporal bone.

    NARCIS (Netherlands)

    Lemmerling, M.M.; Foer, B. De; Verbist, B.M.; Vyver, V. van de

    2009-01-01

    Inflammatory and infectious diseases of the temporal bone are a major indication to perform high-resolution CT and MR imaging studies. Such studies allow one to evaluate the extent of the disease in the soft tissues and in the bony structures of the temporal bone. On these same imaging studies the p

  13. Pediatric mast cell sarcoma of temporal bone with novel L799F (2395 C>T) KIT mutation, mimicking histiocytic neoplasm.

    Science.gov (United States)

    Kim, Young S; Wu, Huiqing; Pawlowska, Anna B; Bautista-Quach, Marnelli A; Huang, Qin; Gaal, Karl; Chang, Karen L

    2013-03-01

    Mast cell sarcoma (MCS) is an extremely rare neoplasm with a clinically aggressive course. Because of its rarity, its morphologic and molecular characteristics are still not well defined. We report a case of a 15-year-old girl with MCS of the temporal bone extending into the posterior fossa creating a mass effect. The lesion mimicked a histiocytic neoplasm morphologically, but showed a novel KIT missense mutation, L799F (2395 C>T). The KIT D816V mutation is frequently found in systemic mastocytosis, but it has not been documented in the few reported human MCS cases. However, 1 reported case of MCS has shown a different alteration in the KIT gene. Our case is the first MCS case with L799F mutation, located between the catalytic loop (790 to 797) and the activation loop (810 to 837) of the KIT gene, and only the second case of MCS with KIT mutation documented in the literature. Proximity of the L799F mutation to the enzymatic region of the KIT tyrosine kinase domain may induce resistance to tyrosine kinase inhibitors.

  14. [Modern imaging of the temporal bone].

    Science.gov (United States)

    Kösling, S

    2017-06-01

    This article describes the current significance of computed tomography (CT), magnetic resonance imaging (MRI), cone beam CT, digital subtraction angiography (DSA), and special X‑rays in the diagnostics of temporal bone diseases. The latter is obsolete for diagnostic intentions. Possibilities and limitations in terms of detection and/or depiction of the extent of inflammatory, traumatic, tumorous, and postoperative pathologies are discussed. A concrete question and conveyance of clinical findings influence the choice of the method to be applied in the individual case. Malformations of the middle ear can only be detected noninvasively by CT or cone beam CT. These are also the methods that may support the diagnosis of otosclerosis in clinically unclear cases. MRI is the method of choice for pathologies of the inner ear and internal auditory canal, including inner ear malformations. At present, only in few institutions is a successful visualization of endolymphatic hydrops in Menière's disease realized.

  15. Osteoradionecrosois of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Thornley, G.D.; Gullane, P.J.; Ruby, R.R.; Heeneman, H.

    1979-10-01

    Six cases of osteoradionecrosis of the temporal bone are described. Persistent symptoms of otitis externa refractory to local treatment measures should alert the physician to the possibility of underlying osteoradionecrosis. Treatment of superficial parotidectomy and partial temporal bone resection with preservation of the facial nerve is indicated if local aggressive conservative measures fail to control the disease. Benign mixed tumors of the parotid gland should be treated surgically with avoidance of radiotherapy.

  16. Diagnosis of ossicular deformities and inner ear anomalies by high resolution CT scanning of the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Isono, Michio

    1988-04-01

    A comparative study was undertaken to determine the optimum slice thickness and slice gaps that can define the fine contour and continuity of the ossicles and the inner ear. Horizontal tomography was proved to be contributory enough to obtain the whole ossicular chains and the whole labyrinthine capsule. Comparison of 1.5 mm slice thickness / 1.5 mm slice gaps, 1.0 mm slice thickness / 1.0 mm slice gaps and 1.5 mm slice thickness / 1.0 mm slice gaps revealed that the last condition was optimal for demonstrating the ossicular chains, the first for the inner ear. A significant relationship was found between CT findings and surgical findings of ossicular chains in chronic otitis media and cholesteatoma. Radiological classification of the inner ear malformation, which was obtained by this method, were agenesis of the whole labyrinthine capsule, agenesis of the cochlea, slight protrusion of the cochlear growth, poor cochlear turning, agenesis of all the semicircular canals, anterior semicircular canals (s.c.) without posterior and lateral s.c., anterior s.c. without hypoplasia of posterior s.c. and aplasia of lateral s.c., and smallness of the vestibule. (author) 59 refs.

  17. FDG PET/CT in bone sarcoidosis.

    Science.gov (United States)

    Grozdic Milojevic, Isidora; Sobic-Saranovic, Dragana; Videnovic-Ivanov, Jelica; Saranovic, Djordjije; Odalovic, Strahinja; Artiko, Vera

    2016-03-29

    Bone sarcoidosis is rare manifestation of disease usually accompanied with pulmonary involvement. Until today, exact prevalence of bone sarcoidosis is not known, since reported prevalence varies widely depending on the studied population and the used diagnostic techniques. To determine the prevalence of bone involvement and distribution pattern in active chronic sarcoidosis by using FDG PET/CT. Between January 2010 and December 2011, 98 patients with chronic sarcoidosis and presence of prolonged symptoms or other findings suggestive of active disease were referred to FDG PET/CT examination. Active disease was found in 82 patients, and they all were screened for presence of bone sarcoidosis on FDG PET/CT. All patients also underwent MDCT and assessment of serum ACE level. Bone sarcoidosis was present in 18/82 patients with active sarcoidosis. FDG uptake in bones was focal in 8 (44.4%), diffuse in 6 (33.3%) and both diffuse and focal in 4 (22.2%) patients. CT indicated bone abnormalities only in 5% patients. Osseous involvement was present in: pelvis (61.1%), vertebrae (44.4%), ribs (27.8%) and bone marrow (16.7%). Some patients had two or more locations of disease. Follow-up FDG PET/CT showed normal findings in two patients, same localization of active disease in four patients and progression of disease in one. In patients with active chronic sarcoidosis 22% of patients had osseous abnormalities on FDG PET/CT that mostly were not detected on CT.

  18. Temporal bone chondroblastoma totally invisible on MRI.

    Science.gov (United States)

    Hiraumi, Harukazu; Arakawa, Yoshiki; Yamamoto, Norio; Sakamoto, Tatsunori; Ito, Juichi

    2016-08-01

    We report a case of temporal bone chondroblastoma that was totally invisible on MRI. The patient was a 64-year-old man who presented with several months history of vertigo. The CT scan with bone window setting showed destruction of the temporomandibular joint, the floor of the middle cranial fossa, and the superior semicircular canal. Calcific foci were seen within the tumor. On MR imaging, the tumor, situating mainly medial to the temporomandibular joint, showed no signal on both T1- and T2-weighted images. The tumor was not enhanced with gadolinium. In summary, the tumor was totally signal negative or "invisible" on pre- and postcontrast T1- and T2-weighted images. The tumor was resected through transpetrosal - transzygomatic approach.

  19. Temporal bone squamous cell carcinoma - Penang experience.

    Science.gov (United States)

    Ng, S Y; Pua, K C; Zahirrudin, Z

    2015-12-01

    Temporal bone squamous cell carcinoma (TBSCC) is rare and poses difficulties in diagnosing, staging and management. We describe a case series with six patients who were diagnosed TBSCC, from January 2009 to June 2014, with median age of 62 years old. All patients presented with blood-stain discharge and external auditory canal mass, showing that these findings should highly alert the diagnosis of TBSCC. Three patients staged T3 and another three with T4 disease. High-resolution CT (HRCT) temporal findings were noted to be different from intraoperative findings and therefore we conclude that MRI should be done to look for middle ear involvement or other soft tissue invasion for more accurate staging. Lateral temporal bone resection (LTBR) and parotidectomy was done for four patients with or without neck dissection. Patients with positive margin, perineural invasion or parotid and glenoid involvement carry poorer prognosis and postoperative radiotherapy may improve the survival rate. One patient had successful tumor resection via piecemeal removal approach in contrast with the recommended en bloc resection shows that with negative margin achieved, piecemeal removal approach can be a good option for patients with T2-3 disease. In general, T4 tumor has dismal outcome regardless of surgery or radiotherapy given.

  20. A Novel Temporal Bone Simulation Model Using 3D Printing Techniques.

    Science.gov (United States)

    Mowry, Sarah E; Jammal, Hachem; Myer, Charles; Solares, Clementino Arturo; Weinberger, Paul

    2015-09-01

    An inexpensive temporal bone model for use in a temporal bone dissection laboratory setting can be made using a commercially available, consumer-grade 3D printer. Several models for a simulated temporal bone have been described but use commercial-grade printers and materials to produce these models. The goal of this project was to produce a plastic simulated temporal bone on an inexpensive 3D printer that recreates the visual and haptic experience associated with drilling a human temporal bone. Images from a high-resolution CT of a normal temporal bone were converted into stereolithography files via commercially available software, with image conversion and print settings adjusted to achieve optimal print quality. The temporal bone model was printed using acrylonitrile butadiene styrene (ABS) plastic filament on a MakerBot 2x 3D printer. Simulated temporal bones were drilled by seven expert temporal bone surgeons, assessing the fidelity of the model as compared with a human cadaveric temporal bone. Using a four-point scale, the simulated bones were assessed for haptic experience and recreation of the temporal bone anatomy. The created model was felt to be an accurate representation of a human temporal bone. All raters felt strongly this would be a good training model for junior residents or to simulate difficult surgical anatomy. Material cost for each model was $1.92. A realistic, inexpensive, and easily reproducible temporal bone model can be created on a consumer-grade desktop 3D printer.

  1. Classification of temporal bone pneumatization based on sigmoid sinus using computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Han, S.-J. [Department of Otorhinolaryngology, National Health Insurance Corporation Ilsan Hospital, Seoul (Korea, Republic of); Song, M.H. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Kim, J. [Department of Radiology, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, W.-S. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of); Lee, H.-K. [Department of Otorhinolaryngology, Yonsei University College of Medicine, Kang-nam Gu, Do-gok Dong, 146-92, Seoul, Republic of Korea 135-720 (Korea, Republic of)], E-mail: hoki@yuhs.ac

    2007-11-15

    Aim: To analyse several reference structures using axial computed tomography (CT) imaging of the temporal bone, which may reflect pneumatization of the entire temporal bone by statistical correlation to the actual volume of the temporal bone measured using three-dimensional reconstruction. Materials and methods: One hundred and sixteen temporal bones were studied, comprising 48 with normal findings and 68 sides showing chronic otitis media or temporal bone fracture. After measuring the volume of temporal bone air cells by the volume rendering technique using three-dimensional reconstruction images, classification of temporal bone pneumatization was performed using various reference structures on axial images to determine whether significant differences in the volume of temporal bone air cells could be found between the groups. Results: When the sigmoid sinus at the level of the malleoincudal complex was used in the classification, there were statistically significant differences between the groups that correlated with the entire volume of the temporal bone. Grouping based on the labyrinth and the ascending carotid artery showed insignificant differences in volume. Furthermore, there was no significant correlation between the cross-sectional area of the antrum and the entire volume of the temporal bone. Conclusion: The degree of pneumatization of temporal bone can be estimated easily by the evaluation of the air cells around the sigmoid sinus on axial CT images.

  2. Measuring temporal resolution of cardiac CT reconstructions

    Science.gov (United States)

    Matthews, David; Heuscher, Dominic

    2005-04-01

    Multi-slice CT today is capable of imaging the heart with excellent temporal resolution. Algorithms have been developed to perform reconstructions combining data from multiple cardiac cycles. This paper presents a simulation phantom that enables a direct measurement of the actual temporal resolution achieved by these algorithms. This is not only useful for assessing the temporal resolution but also for validating the algorithms themselves. A simulation phantom was developed that consists of a 20 cm. diameter water phantom containing an array of cylinders whose intensities are pulsed for various durations ranging from 10 msec. to 250 msec. The intensity varied between the background value of water (0 HU) and 800 HU. By measuring the nominal attenuation value at the center of each cylinder, a curve can be derived representing the response over the given temporal range. A temporal resolution representing the FWHM value is determined based on the half-max value of this curve. Reconstructions were performed using a multi-cycle cardiac algorithm described previously in the literature. The measured FWHM values agree quite well to the temporal resolution predicted by the cardiac algorithm itself. Even the variation along the longitudinal axis can be accounted for by the predicted values. A simulated phantom can be used to accurately assess the temporal resolution of cardiac reconstruction algorithms. Excellent agreement was achieved between the predicted and measured temporal resolution values for the multi-cycle algorithm used in this study.

  3. Schneiderian papilloma of the temporal bone

    NARCIS (Netherlands)

    van der Putten, L.; Bloemena, E.; Merkus, P.; Hensen, E.F.

    2013-01-01

    Temporal bone Schneiderian papilloma may present as a primary tumour originating from the middle ear and mastoid process, or an extension from sinonasal disease. Both forms are rare, this being only the 18th case of primary temporal bone Schneiderian papilloma described to date. Although the current

  4. Study of the feasible size of a bone conduction implant transducer in the temporal bone.

    Science.gov (United States)

    Reinfeldt, Sabine; Östli, Per; Håkansson, Bo; Taghavi, Hamidreza; Eeg-Olofsson, Måns; Stalfors, Joacim

    2015-04-01

    The aim was to assess the temporal bone volume to determine the suitable size and position of a bone conduction implant (BCI) transducer. A BCI transducer needs to be sufficiently small to fit in the mastoid portion of the temporal bone for a majority of patients. The anatomical geometry limits both the dimension of an implanted transducer and its positions in the temporal bone to provide a safe and simple surgery. Computed tomography (CT) scans of temporal bones from 22 subjects were virtually reconstructed. With an algorithm in MATLAB, the maximum transducer diameter as function of the maximum transducer depth in the temporal bone, and the most suitable position were calculated in all subjects. An implanted transducer diameter of 16 mm inserted at a depth of 4 mm statistically fitted 95% of the subjects. If changing the transducer diameter to 12 mm, a depth of 6 mm would fit in 95% of the subjects. The most suitable position was found to be around 20 mm behind the ear canal. The present BCI transducer casing, used in ongoing clinical trials, was designed from the results in this study, demonstrating that the present BCI transducer casing (largest diameter [diagonal]: 15.5 mm, height: 6.4 mm) will statistically fit more than 95% of the subjects. Hence, the present BCI transducer is concluded to be sufficiently small to fit most normal-sized temporal bones and should be placed approximately 20 mm behind the ear canal.

  5. Schneiderian papilloma of the temporal bone.

    Science.gov (United States)

    van der Putten, Lisa; Bloemena, Elisabeth; Merkus, Paul; Hensen, Erik F

    2013-12-05

    Temporal bone Schneiderian papilloma may present as a primary tumour originating from the middle ear and mastoid process, or an extension from sinonasal disease. Both forms are rare, this being only the 18th case of primary temporal bone Schneiderian papilloma described to date. Although the current patient has remained disease free after excision of the papilloma, the reported recurrence rate is high, comparable to sinonasal Schneiderian papilloma with extrasinus extension. Malignant progression of primary Schneiderian papillomas is significantly reduced as compared to Schneiderian papillomas that extend from the sinonasal tract into the temporal bone. A positive human papilloma virus status, as found in this case, is a common feature and prognostic factor of sinonasal Schneiderian papilloma but an infrequent finding in temporal bone disease. Owing to the high recurrence rate, the risk of malignant progression and the absence of reliable prognostic markers, stringent follow-up consisting of otoscopy, nasendoscopy and imaging is essential.

  6. Imaging innovations in temporal bone disorders.

    Science.gov (United States)

    Corrales, C Eduardo; Fischbein, Nancy; Jackler, Robert K

    2015-04-01

    The development of new imaging techniques coupled with new treatment algorithms has created new possibilities in treating temporal bone diseases. This article provides an overview of recent imaging innovations that can be applied to temporal bone diseases. Topics covered include the role of magnetic resonance (MR) diffusion-weighted imaging in cholesteatomas and skull base epidermoids, whole-body molecular imaging in paragangliomas of the jugular foramen, and MR arterial spin labeling perfusion for dural arteriovenous fistulas and arteriovenous malformations.

  7. Standardization of experimental animals temporal bone sections

    Institute of Scientific and Technical Information of China (English)

    Dalian Ding; Jintao Yu; Peng Li; Kelei Gao; Haiyan Jiang; Wenjuan Zhang; Hong Sun; Shankai Yin; Richard Salvi

    2015-01-01

    Preparation of the temporal bone for light microscopy is an important step in histological studies of the inner ear. Due to the complexity of structures of the inner ear, it is difficult to measure or compare structures of interest without a commonly accepted standardized measure of temporal bone sections. Therefore, standardization of temporal bone sections is very important for histological assessment of sensory hair cells and peripheral ganglion neurons in the cochlear and vestibular systems. The standardized temporal bone sectioning is oriented to a plane parallel to the outer and internal auditory canals. Sections are collected from the epitympanum to the hypotympanum to reveal layers in the order of the crista ampullaris of the superior and lateral semicircular canals, macula utriculi and macula sacculi, superior vestibular ganglion neurons, macula of saccule and inferior vestibular ganglion neurons, cochlear modiolus, endolymphatic duct and endolymphatic sac, and finally the crista ampullaris of the posterior semicircular canal. Moreover, technical details of preparing for temporal bone sectioning including fixation, decalcification, whole temporal bone staining, embedding penetration, and embedding orientation are also discussed.

  8. Temporal bone trauma and imaging; Schlaefenbeintrauma und Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Turetschek, K.; Czerny, C.; Wunderbaldinger, P. [Universitaetsklinik fuer Radiodiagnostik, AKH Wien (Austria); Steiner, E. [Inst. fuer Digitale Bilddiagnostik, St. Poelten (Austria)

    1997-12-01

    Fractures of the temporal bone result from direct trauma to the temporal bone or occur as one component of a severe craniocerebral injury. Complications of temporal trauma are hemotympanon, facial nerve paralysis, conductive or sensorineur hearing loss, and leakage of cerebrospinal fluid. Erly recognition and an appropiate therapy may improve or prevent permanent deficits related to such complications. Only 20-30% of temporal bone fractures can be visualized by plain films. CT has displaced plain radiography in the investigation of the otological trauma because subtle bony details are best evaluated by CT which even can be reformatted in multiple projections, regardless of the original plane of scanning. Associated epidural, subdural, and intracerebral hemorrhagic lesions are better defined by MRI. (orig.) [Deutsch] Frakturen des Schlaefenbeins koennen entweder isoliert oder im Rahmen eines schweren Schaedel-/Hirntraumas auftreten. Die haeufigsten Komplikationen dieser Traumen sind Haematotympanon, Fazialisparese, Hoerverlust und eine Liquorfistel. Die prompte und rasche Diagnose dieser Komplikationen sowie eine gezielte Therapie koennen Spaetfolgen (v.a. Hoer- und/oder Gleichgewichtsverlust) verhindern. Auf konventionellen Roentgenaufnahmen koennen nur 20-30% aller Schlaefenbeinfrakturen nachgewiesen werden. Somit ist die Computertomographie bei diesen Patienten heute die Methode der Wahl, da selbst subtile knoecherne Details noch in hervorragender Aufloesung dargestellt werden. Begleitende intrakranielle Komplikationen (epi-/subdurale oder auch intrazerebrale Loesionen) sind mittels Magnetresonanztomographie besser nachweisbar. (orig.)

  9. Giant osteoblastoma of temporal bone: case report

    Directory of Open Access Journals (Sweden)

    FIGUEIREDO EBERVAL GADELHA

    1998-01-01

    Full Text Available Benign osteoblastoma is an uncommon bone tumor accounting for approximately 1% of all bone tumors. There are only 35 cases of skull osteoblastoma reported in the literature. We describe the case of a 23 year old male with a giant osteoblastoma of temporal bone submitted to a total removal of the tumor after an effective embolization of all external carotid branches. The authors discuss diagnostic and management aspects of this uncommon skull tumor.

  10. Traumatic aneurysm of superficial temporal artery. CT demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, A.; Tyagi, G.; Sahai, A.; Baijal, S.S. (G.B. Pant Hospital and M.A. Medical Coll., New Delhi (India). Dept. of Neurosurgery G.B. Pant Hospital and M.A. Medical Coll., New Delhi (India). Dept. of Radiology)

    1991-12-01

    A case of traumatic pseudo-aneurysm of the superficial temporal artery documented on Computed tomography (CT) and angiography is described in a 55-year-old female, who was treated by surgical excision. Computed tomographic appearance of this lesion is illustrated. This represents, to our knowledge, the first CT demonstration of traumatic aneurysm of superficial temporal artery within a large subgaleal haematoma. (orig.).

  11. CT evaluation of primary epiphyseal bone abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Azouz, E.M. (Dept. of Radiology, McGill Univ., Montreal Children' s Hospital, PQ (Canada)); Greenspan, A. (Dept. of Radiology, California Univ., Davis School of Medicine, Sacramento, CA (United States)); Marton, D. (Dept. of Radiology, Montreal Univ., Hopital Ste Justine, PQ (Canada))

    1993-01-01

    We reviewed the clinical, radiographic, and computed tomographic (CT) findings in eight children with a histologically proven diagnosis of epiphyseal or apophyseal osteomyelitis. In all cases the femur was involved: in five the osteomyelitis was localized in the femoral condyle, in two it was in the greater trochanter, and in one it was in the femoral head epiphysis. In four of the six cases of epiphyseal involvement there was associated joint effusion or septic arthritis. CT examination may demonstrate a serpentine tract, a sequestrum, cortical destruction or adjacent soft tissue swelling and can differentiate osteomyelitis from other epiphyseal lucent lesions, particularly chondroblastoma and osteoid osteoma. Early diagnosis helps avoid delays in initiating antibiotic or surgical treatment caused by the unusual (epiphyseal or apophyseal) location of the bone abscess. (orig./GD)

  12. Stereo morphology of temporal bone and ear

    Institute of Scientific and Technical Information of China (English)

    戴朴; 刘阳; 姜泗长; 方耀云; 王今; 杨伟炎

    2004-01-01

    Background The temporal bone has the most complicated anatomic feature among the whole human body, which always challenges otolaryngologists. This study was to study three-dimensional (3D) morphology of the temporal bone and the ear by means of a computer image processing technique, for the purpose of providing a 3D image to help in pathological, diagnostic and surgical procedures. Methods Forty sets of temporal bone celloidin serial sections with reference points were prepared and the contours of selected structures and reference points were entered into a graphics programme. The technique of computer-aided 3D reconstruction was applied to obtain 3D images and parameters of the temporal bones and the ears. Stereo views of the ossicles (n=5), the facial nerves (n=11), the posterior tympanic sinuses (n=11), the posterior ampullary nerves (n=4), the endolymphatic ducts and sacs (n=5), and the bony and membranous labyrinth (n=1) were reconstructed. Results Three-dimensional images, including the cochlea, the ossicles, the nerves, the tendons and the endolymphatic fluid system in the temporal bone, were obtained. Stereo picture pairs and 3D parameters of spatial dimensions, angle and volume for these reconstructed structures were calculated. The arrangement of the ossicles, spatial relationship of the bony and membranous labyrinth, the whole course of the facial nerves, the endolymphatic sac and posterior tympanic cavity were clearly observable. Stereo picture pairs made the spatial relationships among the above-mentioned structures much clearer. The operation of the posterior ampullary nerve transection was designed and simulated on the graphic computer based on 3D anatomic investigations. Conclusion The technique of computer-aided 3D reconstruction provides a new tool to observe the morphology of the temporal bone and thus may allow design and study of new surgical approaches.

  13. Temporal bone fracture and its complications

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective: To explore the characteristics and treatment oftemporal bone fractures and injuries in the medial-inner ear.Methods: The clinical data of 48 cases of temporal bone fractures admitted to our hospital from January 1989 to November 1999 were retrospectively analyzed.Results: Forty-eight patients with temporal bone fractures accounted for 17.00% of the homochronous craniofacial fractures. Of the 48 cases, temporal bone fractures induced by traffic accidents accounted for 66.67%, capillary fractures for 93.75%, medial-inner ear injuries or craniocerebral injuries for 77.08% and hearing loss or tinnitus for 48.00%. The cerebrospinal fluid (CSF) otorrhea and facioplegia accounted for 36.70% and 3.00%, respectively, in the longitudinal fractures, while they were 25.00% and 37.50%, respectively, in the transversal fractures. Primary emergent operations were performed on 46 cases and neurosurgery accounted for 46.00%. Secondary procedures accounted for 16.70%. As a result, 43 cases survived (89.58%) and 5 died (10.41%).Conclusions: Traffic injury is the first high-dangerous factor for temporal bone fractures, which are often complicated with medial-inner ear or craniocerebral injury. The CSF otorrhea is common in the longitudinal fractures and facioplegia is common in the transversal fractures. The key step is to rescue the life, keep the airway unobstructed and maintain the circulation in the primary emergency treatment.

  14. Congenital malformations of the temporal bone.

    Science.gov (United States)

    Mukerji, Shraddha S; Parmar, Hemant A; Ibrahim, Mohannad; Mukherji, Suresh K

    2011-08-01

    Congenital ear or temporal bone malformations are a diagnostic challenge to radiologists and surgeons alike. Newer imaging techniques can detect subtle changes in middle ear and cochlear anatomy. This information is invaluable with increasing use of hearing restoration surgeries and/or cochlear implants in such patients. This article discusses the embryogenesis, classification system, and salient imaging findings of congenital outer, middle ear, and inner ear anomalies in children. Both high-resolution computerized tomography and magnetic resonance imaging scans of the temporal bones are described.

  15. Temporal bone dissection simulator for training pediatric otolaryngology surgeons

    Science.gov (United States)

    Tabrizi, Pooneh R.; Sang, Hongqiang; Talari, Hadi F.; Preciado, Diego; Monfaredi, Reza; Reilly, Brian; Arikatla, Sreekanth; Enquobahrie, Andinet; Cleary, Kevin

    2017-03-01

    Cochlear implantation is the standard of care for infants born with severe hearing loss. Current guidelines approve the surgical placement of implants as early as 12 months of age. Implantation at a younger age poses a greater surgical challenge since the underdeveloped mastoid tip, along with thin calvarial bone, creates less room for surgical navigation and can result in increased surgical risk. We have been developing a temporal bone dissection simulator based on actual clinical cases for training otolaryngology fellows in this delicate procedure. The simulator system is based on pre-procedure CT (Computed Tomography) images from pediatric infant cases (surgery environment, (2) a newly developed haptic interface for holding the surgical drill, (3) an Oculus Rift to provide a microscopic-like view of the temporal bone surgery, and (4) user interface to interact with the simulator through the Oculus Rift and the haptic device. To evaluate the system, we have collected 10 representative CT data sets and segmented the key structures: cochlea, round window, facial nerve, and ossicles. The simulator will present these key structures to the user and warn the user if needed by continuously calculating the distances between the tip of surgical drill and the key structures.

  16. Characteristic anatomical structures of rat temporal bone

    Institute of Scientific and Technical Information of China (English)

    Peng Li; Kelei Gao; Dalian Ding; Richard Salvi

    2015-01-01

    As most gene sequences and functional structures of internal organs in rats have been well studied, rat models are widely used in experi-mental medical studies. A large number of descriptions and atlas of the rat temporal bone have been published, but some detailed anatomy of its surface and inside structures remains to be studied. By focusing on some unique characteristics of the rat temporal bone, the current paper aims to provide more accurate and detailed information on rat temporal bone anatomy in an attempt to complete missing or unclear areas in the existed knowledge. We also hope this paper can lay a solid foundation for experimental rat temporal bone surgeries, and promote information exchange among colleagues, as well as providing useful guidance for novice researchers in the field of hearing research involving rats. Copyright © 2015 The Authors. Production & hosting by Elsevier (Singapore) Pte Ltd On behalf of PLA General Hospital Department of Otolaryngology Head and Neck Surgery. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

  17. Inflammatory diseases of the petrous portion of the temporal bone; Entzuendliche Erkrankungen des Felsenbeins

    Energy Technology Data Exchange (ETDEWEB)

    Koerner, H. [Universitaetsklinikum des Saarlandes, Klinik fuer Diagnostische und Interventionelle Neuroradiologie, Homburg/Saar (Germany)

    2014-04-15

    Inflammatory lesions of the petrous portion of the temporal bone are very common and can be followed by cerebral complications. Thin layer computed tomography (CT) is useful for detecting bony changes of the temporal bone and contrast-enhanced magnetic resonance imaging (CE MRI) is a sensitive method for detecting cerebral complications. (orig.) [German] Entzuendliche Erkrankungen des Felsenbeins sind sehr haeufig und koennen mit zerebralen Komplikationen einhergehen. Mit der Duennschicht-CT lassen sich sehr gut ossaere Veraenderungen im Felsenbein nachweisen. Die kontrastmittelgestuetzte MRT ist sensitiv fuer zerebrale Komplikationen. (orig.)

  18. CT pre-operative planning of a new semi-implantable bone conduction hearing device

    Energy Technology Data Exchange (ETDEWEB)

    Law, Eric K.C.; Bhatia, Kunwar S.S. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Hong Kong, SAR (China); Tsang, Willis S.S.; Tong, Michael C.F. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Otorhinolaryngology, Head and Neck Surgery, Hong Kong, SAR (China); Shi, Lin [The Chinese University of Hong Kong, Department of Medicine and Therapeutics, Hong Kong, SAR (China); The Chinese University of Hong Kong, Chow Yuk Ho Technology Center for Innovative Medicine, Hong Kong, SAR (China)

    2016-06-15

    Accommodating a novel semi-implantable bone conduction hearing device within the temporal bone presents challenges for surgical planning. This study describes the utility of CT in pre-operative assessment of such an implant. Retrospective review of pre-operative CT, clinical and surgical records of 16 adults considered for device implantation. Radiological suitability was assessed on CT using 3D simulation software. Antero-posterior (AP) dimensions of the mastoid bone and minimum skull thickness were measured. CT planning results were correlated with operative records. Eight and five candidates were suitable for device placement in the transmastoid and retrosigmoid positions, respectively, and three were radiologically unsuitable. The mean AP diameter of the mastoid cavity was 14.6 mm for the transmastoid group and 4.6 mm for the retrosigmoid group (p < 0.05). Contracted mastoid and/or prior surgery were predisposing factors for unsuitability. Four transmastoid and five retrosigmoid positions required sigmoid sinus/dural depression and/or use of lifts due to insufficient bone capacity. A high proportion of patients being considered have contracted or operated mastoids, which reduces the feasibility of the transmastoid approach. This finding combined with the complex temporal bone geometry illustrates the importance of careful CT evaluation using 3D software for precise device simulation. (orig.)

  19. Establishing a temporal bone laboratory: considerations for ENT specialist training.

    LENUS (Irish Health Repository)

    Fennessy, B G

    2012-02-01

    Cadaveric temporal bone dissection in a temporal bone laboratory is a vital component in training safe, competent otorhinolaryngologists. Recent controversies pertaining to organ retention have resulted in a more limited supply of temporal bones. Consequently, current trainees are dissecting far fewer bones than their consultants. We discuss the establishment of a temporal bone laboratory in the Department of Anatomy in the University College Cork, from the timely preparation and preservation of the tissue to its disposal. Comparisons are drawn between our experience and that of the United States training schemes. The temporal bone laboratory in Cork is the only one in existence in Ireland. The exposure and experience obtained by registrars rotating through Cork, has resulted in noticeable improvements in their operative abilities. The temporal bone laboratory remains a core component to training. It is hoped that this article may facilitate other units overcoming obstacles to establish a temporal bone laboratory.

  20. A case of mushroom shape temporal bone osteoma.

    Science.gov (United States)

    Akamatsu, Tadashi; Tanaka, Rica; Fukui, Tsuyoshi; Miyasaka, Muneo; Yamada, Shinya

    2009-09-20

    A cranial vault Osteoma is relatively common benign tumor. Mushroom shaped skull osteoma is, however, extremely rare. Twenty seven years old female developed slow growing hard mass posterior to the ear. CT scan revealed a mushroom shaped osseous mass approximately 2.5 cm in diameter protruding from the temporal bone at the site of asterion. And the tumor was located over the right sigmoid sinus. The sigmoid sinus engraved approximately 4mm to the tumor and had a branching to one emissaries' vein. Operation was performed under general anesthesia. The tumor was excised first by cutting the base of the tumor, and then residual tumor was grinded using a round head cutting bar. A chisel dissection was not recommended because of underlining sinus. Histological findings were consistent with a benign osteoma. The postoperative course was uneventful. CT examination immediately done after operation revealed no evidence of intracranial hemorrhage, or injury of vessels. Osetoma was excised, and the surface of cranial bone at the operation site was smooth and cosmetically acceptable. At 6-months follow up, patient remains asymptomatic and recurrence free. CT examination with Multi Planer Reconstruction imaging or 3D reconstruction is highly recommended for the operational planning of cranial osteoma.

  1. Primary Ameloblastoma of the Temporal Bone.

    Science.gov (United States)

    Košec, Andro; Ajduk, Jakov; Ries, Mihael; Trotić, Robert

    2017-06-01

    Ameloblastoma is a locally aggressive tumor derived from odontogenic epithelium. Although benign, its clinical behavior can often exhibit malignant characteristics. It is marked by slow and persistent growth with infiltration of adjacent tissues. Almost 70% occur in the mandible in patients older than 30 years. Recurrence of ameloblastoma from inadequate treatment is frequent. Because of its slow growth, recurrences can present decades after primary surgery. A primary ameloblastoma in an area outside the mandibular, maxillary, and infratemporal fossa regions has not been described in detail to date, with only 1 possible case mentioned in the literature. The authors present a case of primary temporal bone ameloblastoma in a 17-year-old boy. The tumor originated in the left mastoid, infiltrated the lateral semicircular canal, facial nerve, and cochlea, and adhered to the sigmoid sinus and posterior cranial fossa dura. Although invasion of multiple structures in the infratemporal fossa and temporal bone leads to variable disease presentation, this case is unique because the first symptom of disease was sudden and recurring unilateral sensorineural hearing loss. Surgery required transection of the facial nerve. Histopathology confirmed primary temporal bone ameloblastoma. The difficulties in achieving wide surgical margins, diagnostics, and further management are addressed. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Efficacy of DR, CT and MRI in bone tumors

    Institute of Scientific and Technical Information of China (English)

    Yanjiao Zhang; Xuefeng Cui; Changcheng Li; Shenjiang Li

    2014-01-01

    Objective:The aim of the study was to investigate the ef icacy of digital radiography (DR), computed tomography (CT) and magnetic resonance imaging (MRI) in bone tumors. Methods:Fifty-five patients with histological y confirmed bone tumors underwent imaging examinations. Fifty-five patients were performed DR, 21 CT and 20 MRI. Results:DR of 51 pa-tients clearly revealed bone changes. DR of 40 patients wel showed marginal. Twenty tumors appeared periosteal reaction on DR and 19 calcification on DR. CT scan of 21 patients clearly depicted bone changes, marginal and calcification and CT scan of 8 revealed periosteal reaction. MRI scan of 20 patients al showed marginal and soft-tissue mass and bone marrow edema was prominent in 8 patients. Conclusion:DR is the first imaging approach for born tumors. CT wel reveal the extent and minute structure of the bone tumors, the extent, soft-tissue mass and bone marrow edema are more dramatical y demon-strated on MRI imaging. DR integrates with CT and MRI, is helpful in diagnosis of bone tumors.

  3. [A case of chondroblastoma arising from the temporal bone].

    Science.gov (United States)

    Tsutsumi, Satoshi; Mishima, Yumiko; Nonaka, Yasuomi; Abe, Yusuke; Yasumoto, Yukimasa; Ito, Masanori

    2010-11-01

    A 33-year-old male sustained hearing disturbance in the left ear that exacerbated over a period of three years. The patient was referred to the department of otorhynolaryngology for severe stenosis of the left external auditory canal, where neuroimaging study revealed a huge tumor in the left temporal fossa. On first examination, he showed a significant facial nerve paresis and conductive hearing loss. CT scans identified a 4.5×4.5×4.5 cm mass with intralesional calcification and extensive bony destruction in the squamous and petrous parts of the temporal bone and middle cranial fossa floor. MR imaging demonstrated the tumor of heterogenous intensity on T1-and hypointensity on T2-weighted image. The patient underwent gross total resection of the lesion via frontotemporal craniotomy. The bony and ligamentous structures around the temporomandibular joint appeared mostly intact and did not need any reconstructive surgery after tumor resection. Postoperatively the patient's facial nerve paresis showed a transient exacerbation which resolved gradually, while hearing disturbance did not improve. Histological findings of the tumor were consistent with the qualities of chondroblastoma. We should assume chondroblastoma as differential diagnosis when we encounter a temporal bone tumor that is curable by surgical resection.

  4. CT assisted biomimetic artificial bone des

    Institute of Scientific and Technical Information of China (English)

    WANG Xian-gang; ZHANG Chao-zong; GUO Zhi-ping; TIAN Jie-mo

    2001-01-01

    @@ In the recent years, bioceramic materials have been widely used in the clinics. They are mainly fabricated as the substitution of human hard tissue, such as artificial bone and false tooth. As a medical implant, those that have similar structure to human bone have better biocompatibility and osteoinductional property. So it is necessary to design bone model close to human bone.

  5. Bilateral sudden sensorineural hearing loss following unilateral temporal bone fracture.

    Science.gov (United States)

    Hunchaisri, Niran

    2009-06-01

    Temporal bone fractures usually cause unilateral sensorineural hearing loss (SNHL) by fracture that violated otic capsule of that side. Bilateral SNHL from unilateral temporal bone fracture were rarely seen. Labyrinthine concussion was considered to be the pathogenesis in these cases. This article reports an additional case of bilateral SNHL from unilateral temporal bone fracture but in a different pattern of SNHL which may result from an occlusion of the internal auditory artery.

  6. Correlation among external auditory canal anomaly, temporal bone malformation, and hearing levels in patients with microtia.

    Science.gov (United States)

    Chen, Kun; Liu, Liu; Shi, Runjie; Wang, Peihua; Chen, Dong; Xiao, Hua

    2017-06-01

    We conducted a retrospective study to evaluate the relationship between external auditory canal (EAC) anomaly, temporal bone abnormality, and hearing levels using objective scoring systems in Chinese patients with microtia. The study population consisted of 106 ears of 94 Chinese patients (67 male and 27 female) aged 5 to 45 years (mean: 12.6) with microtia. The EAC abnormalities were classified into 4 types according to Schuknecht's criteria: type A, type B, type C, and type D. Developmental anomalies of the temporal bone were evaluated by Jahrsdoerfer computed tomography (CT) scoring system using high-resolution CT scans of the temporal bone. Temporal bone malformation parameters were divided into 4 subgroups: ossicular chain development, windows connected to the cochlea, aeration development of the middle ear, and facial nerve aberration. Hearing levels (air conduction and bone conduction) were examined. Outcomes parameters included correlation coefficients (r) and a number of other variables. The total points (10 points) and subtotal points related to ossicles (4 points), windows (2 points), aeration (2 points), and facial nerve (1 point) correlated inversely with the EAC abnormalities. The hearing levels (air conduction, r = 0.396, p serve as an indicator to determine whether a patient will be suitable for reconstructive surgery.

  7. Radiation injury to the temporal bone

    Energy Technology Data Exchange (ETDEWEB)

    Guida, R.A.; Finn, D.G.; Buchalter, I.H.; Brookler, K.H.; Kimmelman, C.P. (New York Eye and Ear Infirmary/New York Medical College (USA))

    1990-01-01

    Osteoradionecrosis of the temporal bone is an unusual sequela of radiation therapy to the head and neck. Symptoms occur many years after the radiation is administered, and progression of the disease is insidious. Hearing loss (sensorineural, conductive, or mixed), otalgia, otorrhea, and even gross tissue extrusion herald this condition. Later, intracranial complications such as meningitis, temporal lobe or cerebellar abscess, and cranial neuropathies may occur. Reported here are five cases of this rare malady representing varying degrees of the disease process. They include a case of radiation-induced necrosis of the tympanic ring with persistent squamous debris in the external auditory canal and middle ear. Another case demonstrates the progression of radiation otitis media to mastoiditis with bony sequestration. Further progression of the disease process is seen in a third case that evolved into multiple cranial neuropathies from skull base destruction. Treatment includes systemic antibiotics, local wound care, and debridement in cases of localized tissue involvement. More extensive debridement with removal of sequestrations, abscess drainage, reconstruction with vascularized tissue from regional flaps, and mastoid obliteration may be warranted for severe cases. Hyperbaric oxygen therapy has provided limited benefit.

  8. High-resolution computed tomography of the temporal bone. Part 2.: pathology; Kosc skroniowa w tomografii komputerowej wysokiej rozdzielczosci. Czesc 2.: patologia

    Energy Technology Data Exchange (ETDEWEB)

    Grzegorzewski, M.; Boron, Z.; Burzynska-Makuch, M. [Katedra i Zaklad Radiologii i Diagnostyki Narzadowej, Akademia Medyczna, Bydgoszcz (Poland)

    1995-12-31

    Selected cases of the temporal bone pathology on high resolution CT were demonstrated. Transverse and coronal sections of the cases were selected from 68 patients with various otological diseases. (author) 14 refs, 5 figs

  9. Bilateral Facial Paralysis Caused by Bilateral Temporal Bone Fracture: A Case Report and a Literature Review

    Directory of Open Access Journals (Sweden)

    Sultan Şevik Eliçora

    2015-01-01

    Full Text Available Bilateral facial paralysis caused by bilateral temporal bone fracture is a rare clinical entity, with seven cases reported in the literature to date. In this paper, we describe a 40-year-old male patient with bilateral facial paralysis and hearing loss that developed after an occupational accident. On physical examination, House-Brackmann (HB facial paralysis of grade 6 was observed on the right side and HB grade 5 paralysis on the left. Upon temporal bone computed tomography (CT examination, a fracture line exhibiting transverse progression was observed in both petrous temporal bones. Our patient underwent transmastoid facial decompression surgery of the right ear. The patient refused a left-side operation. Such patients require extensive monitoring in intensive care units because the presence of multiple injuries means that facial functions are often very difficult to evaluate. Therefore, delays may ensue in both diagnosis and treatment of bilateral facial paralysis.

  10. Temporal Bone Fracture Causing Superior Semicircular Canal Dehiscence

    Directory of Open Access Journals (Sweden)

    Kevin A. Peng

    2014-01-01

    Full Text Available Importance. Superior semicircular canal dehiscence (SCD is a third window lesion of the inner ear causing symptoms of vertigo, autophony, tinnitus, and hearing loss. A “two-hit” hypothesis has traditionally been proposed, whereby thinly developed bone overlying the superior canal is disrupted by a sudden change in intracranial pressure. Although the symptoms of SCD may be precipitated by head injury, no previous reports have described a temporal bone fracture directly causing SCD. Observations. Two patients sustained temporal bone fractures after closed head trauma, and developed unilateral otologic symptoms consistent with SCD. In each instance, computed tomography imaging revealed fractures extending through the bony roof of the superior semicircular canal. Conclusions and Relevance. Temporal bone fractures, which are largely treated nonoperatively, have not previously been reported to cause SCD. As it is a potentially treatable entity, SCD resulting from temporal bone fracture must be recognized as a possibility and diagnosed promptly if present.

  11. CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

    Energy Technology Data Exchange (ETDEWEB)

    Schnapauff, Dirk, E-mail: dirk.schnapauff@charite.de; Marnitz, Tim, E-mail: tim.marnitz@charite.de; Freyhardt, Patrick, E-mail: Patrick.freyhardt@charite.de; Collettini, Federico, E-mail: Federico.collettini@charite.de [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Department of Radiology (Germany); Hartwig, Kerstin, E-mail: kerstin.hartwig@charite.de [Charite Universitaetsmedizin Berlin, Campus Charite Mitte, Department of Haematology and Oncology (Germany); Joehrens, Korinna, E-mail: korinna.joehrens@charite.de [Charite Universitaetsmedizin Berlin, Campus Charite Mitte, Department of Pathology (Germany); Hamm, Bernd, E-mail: bernd.hamm@charite.de; Kroencke, Thomas, E-mail: thomas.kroencke@charite.de; Gebauer, Bernhard, E-mail: Bernhard.gebauer@charite.de [Charite Universitaetsmedizin Berlin, Campus Virchow-Klinikum, Department of Radiology (Germany)

    2013-10-15

    Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.

  12. Cadaveric Temporal Bone Dissection: Is It Obsolete Today?

    Directory of Open Access Journals (Sweden)

    Naik, Sulabha M.

    2014-01-01

    Full Text Available Introduction Traditionally, surgical training in otology, is imparted by dissecting harvested human cadaveric temporal bones. However, maintenance of a cadaveric temporal bone laboratory is expensive and carries risk of exposure to infection. In recent times, other modalities of training are gaining ground and are likely to eventually replace cadaveric temporal bone dissection altogether. Objectives Other alternative methods of training are emerging. New technology like simulation and virtual reality as high-fidelity, safer alternatives, are making rapid strides as teaching tools. Other options are the use of animal temporal bones as teaching tools. The advantages of these are compared. Data Synthesis None of these modalities can replicate the innumerable anatomical variations which are a characteristic feature of the human temporal bone. A novice surgeon not only needs exposure to surgical anatomy and it's variations but also needs to develop hand-eye coordination skills to gain expertise. Conclusion Deliberate practice on human cadaveric temporal bones only, will confer both mastery in anatomy and surgical technique. The human cadaveric temporal bone is ideal simulator for training in otology.

  13. Temporal bone dissection practice using a chicken egg.

    Science.gov (United States)

    Meléndez García, José Manuel; Araujo Da Costa, Ana Sofía; Rivera Schmitz, Teresa; Chiesa Estomba, Carlos Miguel; Hamdan Zavarce, Miriam Ileana

    2014-07-01

    Temporal bone drilling practice constitutes an essential stage in training for the surgical approach to this complex anatomic structure. To facilitate adaptation and surgical skills in otologic surgery, we recall the easy cost-effective practice of drilling a chicken egg. The resident in training must master the use of the surgical microscope, the burr, and fine drilling instruments used in dissection. Animal models, plastic temporal bones, prototyped temporal bones, and virtual reality temporal bones have all been used. This article describes a method of training residents' otologic skills by drilling a chicken egg. We used basic support materials found in a typical temporal bone dissection laboratory, with a surgical microscope, a desk, and a drilling system. Practice includes drilling and dissection of the eggshell, preserving the natural eggshell membrane. Learning temporal bone drilling on an egg, using basic materials, allows the surgeon to simulate surgery on a physical model using the same instrumentation that is used in surgery, obviating the need for laboratory conditions required for cadaveric dissection. Simulation is emerging as a mandatory component of surgical training. The egg is an excellent cost-effective model for drilling and dissection training and helps in improving surgical skills, enables learning of fine motor skills, and allows repeated practice. Although this method of training does help one control a drill and manual instrumentation, it does not help with temporal bone anatomy knowledge.

  14. A temporal interpolation approach for dynamic reconstruction in perfusion CT.

    Science.gov (United States)

    Montes, Pau; Lauritsch, Günter

    2007-07-01

    This article presents a dynamic CT reconstruction algorithm for objects with time dependent attenuation coefficient. Projection data acquired over several rotations are interpreted as samples of a continuous signal. Based on this idea, a temporal interpolation approach is proposed which provides the maximum temporal resolution for a given rotational speed of the CT scanner. Interpolation is performed using polynomial splines. The algorithm can be adapted to slow signals, reducing the amount of data acquired and the computational cost. A theoretical analysis of the approximations made by the algorithm is provided. In simulation studies, the temporal interpolation approach is compared with three other dynamic reconstruction algorithms based on linear regression, linear interpolation, and generalized Parker weighting. The presented algorithm exhibits the highest temporal resolution for a given sampling interval. Hence, our approach needs less input data to achieve a certain quality in the reconstruction than the other algorithms discussed or, equivalently, less x-ray exposure and computational complexity. The proposed algorithm additionally allows the possibility of using slow rotating scanners for perfusion imaging purposes.

  15. Temporal Bone Pneumatization and Pulsatile Tinnitus Caused by Sigmoid Sinus Diverticulum and/or Dehiscence

    Directory of Open Access Journals (Sweden)

    Liu Wenjuan

    2015-01-01

    Full Text Available Background. Although air cells within temporal bone may play an important role in the transmission of pulsatile tinnitus (PT noise, it has not been studied systematically. Purpose. To evaluate the difference in temporal bone pneumatization between PT patients with sigmoid sinus diverticulum and/or dehiscence (SSDD and healthy people. Material and Methods. A total of 199 unilateral persistent PT patients with SSDD and 302 control subjects underwent dual-phase contrast-enhanced CT (DP-CECT, to assess the grade of temporal bone pneumatization in each ear. Results. In the bilateral temporal bone of 302 controls, 16 ears were grade I, 53 were grade II, 141 were grade III, and 394 were grade IV. Among the affected ears of 199 PT cases, 1 ear was grade I, 18 were grade II, 53 were grade III, and 127 were grade IV. There was no significant difference in the pneumatization grade between the affected PT ear and either ear in the healthy subjects (p>0.05.  Conclusion. Although air cells within the temporal bone are an important factor in the occurrence of PT, its severity does not differ significantly from the pneumatization of healthy people.

  16. Surgical treatment and outcomes of temporal bone chondroblastoma.

    Science.gov (United States)

    Moon, In Seok; Kim, Jin; Lee, Ho-Ki; Lee, Won-Sang

    2008-12-01

    Chondroblastoma is an uncommon primary benign bone tumor that usually arises in the epiphyses of the long bones. Temporal bone chondroblastoma is a rare primary bone tumor that affects the floor of the middle cranial fossa and temporomandibular joint (TMJ). The biological nature of temporal bone chondroblastoma is occasionally aggressive because of local invasion and is known to have a high recurrence after curettage. Therefore, complete resection is recommended. However, the literature provides little information regarding long-term surgical outcomes and complications after surgical resection. The authors have retrospectively analyzed four cases of temporal bone chondroblastoma that had been completely excised by a single surgeon with an eventual long-term follow-up. A single surgeon operated on four patients, two males and two females, with a mean age of 34 years, at the Department of Otorhinolaryngology, Severance Hospital. In all cases, the tumor involved the middle cranial fossa dura and the mandibular fossa with variable degree of infiltration. All patients have had no tumor recurrence to date (mean follow-up period of 5 years). Complete surgical resection of the temporal bone chondroblastoma is the gold standard for treatment. Precise preoperative image evaluation of tumor extension and proper management of the dura mater and temporomandibular joint (TMJ) are the major important features in complete surgical removal that minimize complications in temporal bone chondroblastoma treatment.

  17. Aspects of temporal bone anatomy and pathology in conjunction with cochlear implant surgery

    Energy Technology Data Exchange (ETDEWEB)

    Stjernholm, Christina [Karolinska Inst., Stockholm (Sweden). Soedersjukhuset

    2003-07-01

    Cochlear implantation is a treatment for patients with severe sensorineural hearing loss/deafness, who get no help from ordinary hearing aids. The cochlear implant is surgically placed under the skin near the ear and a very thin electrode array is introduced into the cochlea of the inner ear, where it stimulates the remaining nerve fibers. The operation is complicated; it is performed with the aid of a microscope, and involves drilling very close to vital vessels and important nerves. High resolution computed tomography (CT) of the temporal bone is a part of the preoperative evaluation preceding cochlear implantation. It is a method for visualizing the bony structures of the middle and inner ear - to diagnose pathology and to describe the anatomy. The first work concerns CT of the temporal bone and cochlear implant surgery in children with CHARGE association. This is a rare condition with multiple congenital abnormalities, sometimes lethal. Children with CHARGE have different combinations of disabilities, of which impairments of vision and hearing, as well as balance problems and facial palsy can lead to developmental delay. There have been few reports of radiological temporal bone changes and none of cochlear implant surgery for this group. The work includes a report of the findings on preoperative CT and at surgery, as well as postimplant results in two children. A review of the latest diagnostic criteria of CHARGE and the temporal bone changes found in international literature is also included. The conclusion was that certain combinations of temporal bone changes in CHARGE are, if not specific, at least extremely rare in other materials. CT can visualize these changes and be used as a diagnostic tool. This is important, since some of the associated disabilities are not so obvious from the start. Early treatment is vital for the child's development. This work also shows that cochlear implantation may help some of these often very isolated children to

  18. [Computed tomography and magnetic resonance imaging of congenital abnormalities of the temporal bone].

    Science.gov (United States)

    Czerny, C; Gstöttner, W; Imhof, H

    2003-03-01

    Congenital abnormalities of the temporal bone are mostly accompanied by conductive or sensori-neural hearing loss. Before any therapeutic procedures are done high resolution CT (HRCT) and magnetic resonance imaging (MRI) should be performed to establish the correct diagnosis and to plan the potentially surgical intervention. HRCT best depicts osseous changes especially those of the external auditory canal and the middle ear containing the ossicles and the osseous structures of the temporal bone and the petrous bone containing the inner ear. MRI excellently shows soft tissue changes of the inner ear especially on the high resolution 3DT2-weighted sequences which give a superb contrast between the nerves and the cerebro-spinal fluid. Malformations of the external auditory canal consists of aplasia or hypoplasia and those of the middle ear range form extreme hypoplasia or aplasia to very mild deformations of the ossicles. Malformations of the inner ear also range form complete aplasia to very mild hypoplasia of the organs of the inner ear as well as malformations concerning the nerves in the internal auditory canal range from aplasia to hypoplasia. Malformations of the temporal bone can either occur isolated or in combination in which malformations of the external and middle ear may be accompanied by those of the inner ear. Furthermore, malformations of the temporal bone may also occur in otofacial, otocervical or otoskeletal syndromes. These syndromes may be accompanied by certain malformations of the temporal bone. HRCT and MRI are both excellent methods to depict congenital abnormalities of the temporal bone and of the inner ear and should be used as complementary methods because HRCT best depicts osseous changes and MRI superbly depicts soft tissue changes. Both methods are important to establish the correct diagnosis to plan the therapeutic procedures.

  19. Joint regularization for spectro-temporal CT reconstruction

    Science.gov (United States)

    Clark, D. P.; Badea, C. T.

    2016-03-01

    X-ray CT is widely used, both clinically and preclinically, for fast, high-resolution, anatomic imaging; however, compelling opportunities exist to expand its use in functional imaging applications. For instance, spectral information combined with nanoparticle contrast agents enables quantification of tissue perfusion levels, while temporal information details cardiac and respiratory dynamics. In previous work, we proposed and demonstrated a projection acquisition and reconstruction strategy for 5D CT (3D + dual-energy + time) which recovered spectral and temporal information without substantially increasing radiation dose or sampling time relative to anatomic imaging protocols. The approach relied on the approximate separability of the temporal and spectral reconstruction sub-problems, which enabled substantial projection undersampling and effective regularization. Here, we extend this previous work to more general, nonseparable 5D CT reconstruction cases (3D + muti-energy + time) with applicability to K-edge imaging of exogenous contrast agents. We apply the newly proposed algorithm in phantom simulations using a realistic system and noise model for a photon counting x-ray detector with six energy thresholds. The MOBY mouse phantom used contains realistic concentrations of iodine, gold, and calcium in water. Relative to weighted least-squares reconstruction, the proposed 5D reconstruction algorithm improved reconstruction and material decomposition accuracy by 3-18 times. Furthermore, by exploiting joint, low rank image structure between time points and energies, ~80 HU of contrast associated with the Kedge of gold and ~35 HU of contrast associated with the blood pool and myocardium were recovered from more than 400 HU of noise.

  20. Bone marrow metastases from alveolar rhabdomyosarcoma with impressive FDG PET/CT finding but less-revealing bone scintigraphy.

    Science.gov (United States)

    Yang, Jigang; Zhen, Lishi; Zhuang, Hongming

    2013-12-01

    An 18F-FDG PET/CT scan was performed in a 26-year-old man with a known alveolar rhabdomyosarcoma for staging. The PET/CT scan showed abnormally increased FDG activity involving almost all bones in the imaged regions. In contrast, 99mTc-MDP whole-body bone scan demonstrated only very limited bone metastases.

  1. Temporal subtraction contrast-enhanced dedicated breast CT

    Science.gov (United States)

    Gazi, Peymon M.; Aminololama-Shakeri, Shadi; Yang, Kai; Boone, John M.

    2016-09-01

    The development of a framework of deformable image registration and segmentation for the purpose of temporal subtraction contrast-enhanced breast CT is described. An iterative histogram-based two-means clustering method was used for the segmentation. Dedicated breast CT images were segmented into background (air), adipose, fibroglandular and skin components. Fibroglandular tissue was classified as either normal or contrast-enhanced then divided into tiers for the purpose of categorizing degrees of contrast enhancement. A variant of the Demons deformable registration algorithm, intensity difference adaptive Demons (IDAD), was developed to correct for the large deformation forces that stemmed from contrast enhancement. In this application, the accuracy of the proposed method was evaluated in both mathematically-simulated and physically-acquired phantom images. Clinical usage and accuracy of the temporal subtraction framework was demonstrated using contrast-enhanced breast CT datasets from five patients. Registration performance was quantified using normalized cross correlation (NCC), symmetric uncertainty coefficient, normalized mutual information (NMI), mean square error (MSE) and target registration error (TRE). The proposed method outperformed conventional affine and other Demons variations in contrast enhanced breast CT image registration. In simulation studies, IDAD exhibited improvement in MSE (0-16%), NCC (0-6%), NMI (0-13%) and TRE (0-34%) compared to the conventional Demons approaches, depending on the size and intensity of the enhancing lesion. As lesion size and contrast enhancement levels increased, so did the improvement. The drop in the correlation between the pre- and post-contrast images for the largest enhancement levels in phantom studies is less than 1.2% (150 Hounsfield units). Registration error, measured by TRE, shows only submillimeter mismatches between the concordant anatomical target points in all patient studies. The algorithm was

  2. The temporal response of bone to unloading

    Science.gov (United States)

    Globus, R. K.; Bikle, D. D.; Morey-Holton, E.

    1984-01-01

    Rats were suspended by their tails with the forelimbs bearing the weight load to simulate the weightlessness of space flight. Growth in bone mass ceased by 1 week in the hindlimbs and lumbar vertebrae in growing rats, while growth in the forelimbs and cervical vertebrae remained unaffected. The effects of selective skeletal unloading on bone formation during 2 weeks of suspension was investigated using radio iostope incorporation (with Ca-45 and H-3 proline) and histomorphometry (with tetracycline labeling). The results of these studies were confirmed by histomorphometric measurements of bone formation using triple tetracycline labeling. This model of simulated weightlessness results in an initial inhibition of bone formation in the unloaded bones. This temporary cessation of bone formation is followed in the accretion of bone mass, which then resumes at a normal rate by 14 days, despite continued skeletal unloading. This cycle of inhibition and resumption of bone formation has profound implication for understanding bone dynamics durng space flight, immobilization, or bed rest and offers an opportunity to study the hormonal and mechanical factors that regulate bone formation.

  3. Percutaneous CT guided bone biopsy in patients with suspected bone neoplasm

    Energy Technology Data Exchange (ETDEWEB)

    Yasui, Kotaro; Kanazawa, Susumu; Tanaka, Akio; Hiraki, Yoshio [Okayama Univ. (Japan). School of Medicine

    1996-03-01

    Bone biopsy is necessary for the diagnosis of ambiguous, skeletal lesions. Although several merits of computed tomography (CT)-guided percutaneous needle biopsy have been documented, few radiologists have performed this procedure in Japan. We performed this procedure with a newly introduced bone biopsy needle (OSTYCUT, angiomed, Karlsruhe, Germany) under CT guidance and evaluated the results. CT-guided bone biopsy (pelvic [n=11] vertebral [n=10], femoral [n=1], stemal [n=1]) was performed in 19 consecutive patients. Seventeen patients were suspected metastatic disease, and the others were suspected primary bone tumor. All biopsies but one were diagnostic. Malignancy was proved in 11 lesions. Three patients with prostatic carcinoma were proved to show no malignancy of bone lesions after a series of hormonal and chemotherapies. In one patient with both malignant mesothelioma and cervical carcinoma, the biopsy specimen from thoracic vertebra proved metastasis from mesothelioma. CT-guided bone biopsy is useful to evaluate the presence of malignancy and the effect of therapy for it, and to determine the primary site. (author).

  4. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Julka, Pramod Kumar [All India Institute of Medical Sciences, Department of Radiation Oncology, New Delhi (India); Thulkar, Sanjay [All India Institute of Medical Sciences, Department of Radiodiagnosis, New Delhi (India)

    2012-07-15

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 {+-} 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score {<=}2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images ({kappa} = 0.426), while almost perfect agreement was seen for CT ({kappa} = 0.834) and SPECT-CT ({kappa} = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  5. An autopsy case of otogenic intracranial abscess and meningitis with Bezold's abscess: evaluation of inflammatory bone destruction by postmortem cone-beam CT.

    Science.gov (United States)

    Kanawaku, Yoshimasa; Yanase, Takeshi; Hayashi, Kino; Harada, Kazuki; Kanetake, Jun; Fukunaga, Tatsushige

    2013-11-01

    The deceased was an unidentified young male found unconscious on a walkway. On autopsy, outer and inner fistulae of the left temporal bone, subcutaneous abscess in the left side of the neck and head, and an intracranial abscess were noted. A portion of the left temporal bone was removed and scanned by cone-beam computed tomography (CT) (normally used for dentistry applications) to evaluate the lesion. The cone-beam CT image revealed roughening of the bone wall and hypolucency of the mastoid air cells, consistent with an inflammatory bone lesion. According to autopsy and imaging findings, the cause of death was diagnosed as intracranial abscess with Bezold's abscess secondary to left mastoiditis as a complication of otitis media. Although determining the histopathology of bone specimens is time-consuming and costly work, we believe that use of cone-beam CT for hard tissue specimens can be useful in forensic practice.

  6. Myxoma of the temporal bone: A rare neoplasm

    Directory of Open Access Journals (Sweden)

    Kapil Sikka

    2011-01-01

    Full Text Available Myxomas of the temporal bone are rare mesenchymal tumors. We present a case of a 16-year-old girl who presented with complaint of mass lesion protruding from the right ear canal and from behind the ear for last 2 years. Biopsy of the mass was suggestive of benign mesenchymal lesion with prominent myxoid changes. Radiology of the temporal bone showed soft tissue density involving right side external auditory canal, middle ear, mastoid antrum and both lobes of the parotid gland. Tumour excision along with total parotidectomy was performed. Postoperative histopatholgy was consistent with myxoma. The patient is on regular follow-up for last 5months with no recurrence till date. Temporal bone myxomas are rare neoplasms which are surgically treatable but have a strong tendency to recur, necessiating long-term follow-up.

  7. Massive Cerebrospinal Fluid Leak of the Temporal Bone

    Directory of Open Access Journals (Sweden)

    Giannicola Iannella

    2016-01-01

    Full Text Available Cerebrospinal fluid (CSF leakage of the temporal bone region is defined as abnormal communications between the subarachnoidal space and the air-containing spaces of the temporal bone. CSF leak remains one of the most frequent complications after VS surgery. Radiotherapy is considered a predisposing factor for development of temporal bone CSF leak because it may impair dural repair mechanisms, thus causing inadequate dural sealing. The authors describe the case of a 47-year-old man with a massive effusion of CSF which extended from the posterior and lateral skull base to the first cervical vertebrae; this complication appeared after a partial enucleation of a vestibular schwannoma (VS with subsequent radiation treatment and second operation with total VS resection.

  8. Characteristics of osteoma of the temporal bone in young adolescents.

    Science.gov (United States)

    Viswanatha, Borlingegowda

    2011-02-01

    The author conducted a retrospective review of the clinical presentation, management, and complications of temporal bone osteoma in young adolescents. The study population was made up of 9 patients-5 girls and 4 boys, aged 12 to 15 years at presentation (mean: 13.7)-who had been seen for radiologically and histopathologically proven temporal bone osteoma at the author's institution over a 9-year period. Of this group, 5 patients had extracanalicular osteoma (3 in the mastoid portion of the temporal bone, 1 in the squamous portion, and 1 in the mastoid antrum) and 4 patients had osteoma of the external auditory canal. Six of the 9 patients underwent surgical treatment; of the remainder, 1 refused surgery and 2 were managed conservatively with ongoing observation. All patients were followed for a minimum of 1 year, and no recurrences and no complications were observed during that time.

  9. Variability of the temporal bone surface's topography: implications for otologic surgery

    Science.gov (United States)

    Lecoeur, Jérémy; Noble, Jack H.; Balachandran, Ramya; Labadie, Robert F.; Dawant, Benoit M.

    2012-02-01

    Otologic surgery is performed for a variety of reasons including treatment of recurrent ear infections, alleviation of dizziness, and restoration of hearing loss. A typical ear surgery consists of a tympanomastoidectomy in which both the middle ear is explored via a tympanic membrane flap and the bone behind the ear is removed via mastoidectomy to treat disease and/or provide additional access. The mastoid dissection is performed using a high-speed drill to excavate bone based on a pre-operative CT scan. Intraoperatively, the surface of the mastoid component of the temporal bone provides visual feedback allowing the surgeon to guide their dissection. Dissection begins in "safe areas" which, based on surface topography, are believed to be correlated with greatest distance from surface to vital anatomy thus decreasing the chance of injury to the brain, large blood vessels (e.g. the internal jugular vein and internal carotid artery), the inner ear, and the facial nerve. "Safe areas" have been identified based on surgical experience with no identifiable studies showing correlation of the surface with subsurface anatomy. The purpose of our study was to investigate whether such a correlation exists. Through a three-step registration process, we defined a correspondence between each of twenty five clinically-applicable temporal bone CT scans of patients and an atlas and explored displacement and angular differences of surface topography and depth of critical structures from the surface of the skull. The results of this study reflect current knowledge of osteogenesis and anatomy. Based on two features (distance and angular difference), two regions (suprahelical and posterior) of the temporal bone show the least variability between surface and subsurface anatomy.

  10. Usefulness of three-phase bone scintigraphy and SPECT/CT for the diagnosis of bone lesions of systemic sarcoidosis

    Directory of Open Access Journals (Sweden)

    Shigeaki Higashiyama

    2014-05-01

    The findings of the three-phase bone scintigraphy and SPECT/CT suggested the presence of systemic sarcoidosis; however, a subsequent 18Ffluorodeoxyglucose positron emission tomography/CT (FDG-PET/CT could not exclude the possibility of multiple metastases from testicular tumors. Therefore, testicular enucleation was performed, and the pathological examination confirmed the presence of sarcoidosis.

  11. Volumetric analysis of corticocancellous bones using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Linde, Astrid von; Rosenberger, Ralf; Blauth, Michael [Medical University Innsbruck, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria); Glodny, Bernhard; Niederwanger, Christian [Medical University Innsbruck, Department of Radiology I, Innsbruck (Austria)

    2012-05-15

    To present a method for an automated volumetric analysis of corticocancellous bones such as the superior pubic ramus using CT data and to assess the reliability of this method. Computed tomography scans of a consecutive series of 250 patients were analyzed. A Hounsfield unit (HU) thresholding-based reconstruction technique (''Vessel Tracking,'' GE Healthcare) was used. A contiguous space of cancellous bone with similar HU values between the starting and end points was automatically identified as the region of interest. The identification was based upon the density gradient to the adjacent cortical bone. The starting point was defined as the middle of the parasymphyseal corticocancellous transition zone on the axial slice showing the parasymphyseal superior pubic ramus in its maximum anteroposterior width. The end point was defined as the middle of the periarticular corticocancellous transition zone on the axial slice showing the quadrilateral plate as a thin cortical plate. The following parameters were automatically obtained on both sides: length of the center line, volume of the superior pubic ramus between the starting point and end point, minimum, maximum and mean diameter perpendicular to the center line, and mean cross-sectional area perpendicular to the center line. An automated analysis without manual adjustments was successful in 207 patients (82.8%). The center line showed a significantly greater length in female patients (67.6 mm vs 65.0 mm). The volume was greater in male patients (21.8 cm{sup 3} vs 19.4 cm{sup 3}). The intersite reliability was high with a mean difference between the left and right sides of between 0.1% (cross-sectional area) and 2.3% (volume). The method presented allows for an automated volumetric analysis of a corticocancellous bone using CT data. The method is intended to provide preoperative information for the use of intramedullary devices in fracture fixation and percutaneous cement augmentation techniques

  12. Comparison of FDG-PET/CT and bone scintigraphy for detection of bone metastases in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Steffen; Heusner, Till; Forsting, Michael; Antoch, Gerald (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)), email: steffen.hahn@uk-essen.de; Kuemmel, Sherko; Koeninger, Angelika (Dept. of Gynecology and Obstetrics, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)); Nagarajah, James; Mueller, Stefan; Boy, Christian; Bockisch, Andreas; Stahl, Alexander (Dept. of Nuclear Medicine, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany))

    2011-11-15

    Background Bone scintigraphy is the standard procedure for the detection of bone metastases in breast cancer patients. FDG-PET/CT has been reported to be a sensitive tool for tumor staging in different malignant diseases. However, its accuracy for the detection of bone metastases has not been compared to bone scintigraphy. Purpose To compare whole-body FDG-PET/CT and bone scintigraphy for the detection of bone metastases on a lesion basis in breast cancer patients. Material and Methods Twenty-nine consecutive women (mean age 58 years, range 35-78 years) with histologically proven breast cancer were assessed with bone scintigraphy and whole-body FDG-PET/CT. Twenty-one patients (72%) were suffering from primary breast cancer and eight patients (28%) were in aftercare with a history of advanced breast cancer. Both imaging procedures were assessed for bone metastases by a radiologist and a nuclear medicine physician. Concordant readings between bone scintigraphy and FDG-PET/CT were taken as true. Discordant readings were verified with additional MRI imaging in all patients and follow-up studies in most patients. Results A total of 132 lesions were detected on bone scintigraphy, FDG-PET/CT or both. According to the reference standard, 70/132 lesions (53%) were bone metastases, 59/132 lesions (45%) were benign, and three lesions (2%) remained unclear. The sensitivity of bone scintigraphy was 76% (53/70) compared to 96% (67/70) for FDG-PET/CT. The specificity of bone scintigraphy and FDG-PET/CT was 95% (56/59) and 92% (54/59), respectively. According to the reference standard bone metastases were present in eight out of the 29 patients (28%), whereas 20 patients (69%) were free of bone metastases. One (3%) patient had inconclusive readings on both modalities as well as on MRI and follow-up studies. Bone scintigraphy and FDG-PET/CT correctly identified seven out of eight patients with bone metastases and 20 out of 20 patients free of metastases. Conclusion On a lesion

  13. Good experiences with interactive temporal bone surgical simulator

    DEFF Research Database (Denmark)

    Andersen, Steven A W; Mikkelsen, Peter Trier; Noe, Karsten Ostergaard;

    2014-01-01

    The Visible Ear Simulator (VES) is a freeware temporal bone surgical simulator utilizing a high-fidelity haptic and graphical voxel model compiled from segmented digital images of fresh frozen sections. A haptic device provides the 3-dimensional handling and drilling with force-feedback in real...

  14. Temporal bone verrucous carcinoma: outcomes and treatment controversy

    Science.gov (United States)

    Martin, Neil; Juillard, Guy F.; Bhuta, Sunita; Ishiyama, Akira

    2010-01-01

    Verrucous carcinoma is a rare tumor that presents in the head and neck with the most common sites being the oral cavity and larynx. Fourteen cases of verrucous carcinoma of the temporal bone have been described in literature; this study aims to examine treatment outcomes and discuss the controversy surrounding postoperative radiation. The study design included a literature review along with individual case report in the setting of a tertiary care medical center. Outcome analysis of all cases of verrucous carcinoma of the temporal bone, which are documented in the English literature, and presentation of a single patient report including gross, histologic and radiologic analyses were performed. The longest recorded survival for verrucous carcinoma of the temporal bone occurs in patients treated with surgery alone. Poorer outcomes for patients treated with adjuvant (chemo)radiation may be due to more advanced stage of disease at the time of treatment. Early reports of radiation leading to tumor dedifferentiation or early recurrence are not supported by more recent studies. Whether adjuvant radiation therapy is indicated in verrucous carcinoma of the temporal bone remains controversial. PMID:20502907

  15. Langerhans cell histiocytosis of the temporal bone in a child

    Directory of Open Access Journals (Sweden)

    A Chakravarti

    2011-12-01

    Full Text Available Langerhans cell histiocytosis of temporal bone is a benign tumor like condition with variable clinical course. This rare clinical entity may mimic common ENT clinical condition like otitis media , mastoiditis and otitis externa . A high index of suspicion is required to reach to a diagnosis of langerhans cell histiocytosis to prevent delay in proper management of this disease.

  16. Infantile desmoid-type fibromatosis with involvement of temporal bone: case report

    Energy Technology Data Exchange (ETDEWEB)

    Hagen, T. [Dept. of Neuroradiology, Saarland Univ., Homburg (Germany); Feiden, W. [Dept. of Neuropathology, Saarland Univ., Homburg (Germany); Piepgras, U. [Dept. of Neuroradiology, Saarland Univ., Homburg (Germany)

    1995-12-31

    Infantile desmoid-type fibromatosis is a rare, benign, infiltratively growing tumor of the soft tissue. The histological classification is often confusing due to various patterns. Although surgical excision is the treatment of choice, local recurrence is high. Ultrasound, CT, and MRI cannot differentiate the different types of fibrous lesions, but are very essential, showing the localization and infiltrated tissues. We report an unusual case of desmoid-type fibromatosis destroying the temporal bone in a now-5-year-old boy. The literature contains only few reports of radiological findings in patients with infantile fibromatosis. (orig.)

  17. Bilateral Non-Hodgkin’s Lymphoma of the Temporal Bone: A Rare and Unusual Presentation

    Directory of Open Access Journals (Sweden)

    Sanjay Vaid

    2016-01-01

    Full Text Available Primary lymphoma of the temporal bone is an unusual finding in clinical practice and bilateral affection is even more rare. To the best of our knowledge, there are no reports of bilateral primary temporal bone lymphoma without middle ear involvement in the English medical literature so far. We report, for the first time, a case of primary lymphoma involving both temporal bones which presented with left-sided infranuclear facial palsy. A combination of contrast enhanced magnetic resonance imaging (MRI and high resolution computed tomography (HRCT was used to characterize and to map the extent of the lesion, as well as to identify the exact site of facial nerve affection. An excision biopsy and immunohistochemistry revealed diffuse large B-cell non-Hodgkin’s lymphoma (DLBCL. Whole body fluorodeoxyglucose (FDG positron emission tomography-computed tomography study (PET-CT was performed to stage the disease. The patient was treated with chemotherapy and radiation therapy and is now on regular follow-up. The patient is alive and asymptomatic without disease progression for the last twenty months after initial diagnosis.

  18. Osteoradionecrosis of the Temporal Bone Leading to Cerebellar Abscess.

    Science.gov (United States)

    Layton, Thomas B

    2017-01-01

    Squamous cell carcinoma of the temporal bone is a rare and destructive malignancy and represents both diagnostic and therapeutic challenge. The complex regional anatomy of the temporal bone requires equally intricate surgical techniques to adequately resect the tumour mass during surgical excision. Adjuvant radiotherapy is offered to patients with advanced disease and has been showed to confer a survival benefit in carefully selected patients. One feared complication of radiotherapy is osteoradionecrosis and is a major obstacle faced in the treatment of head and neck cancers. The case presented here is a rare example of a patient who was successfully treated for SCC of the temporal with both surgical resection and adjuvant radiotherapy who subsequently developed two major complications: first, osteoradionecrosis of the temporal bone that leads to penetrating osteomyelitis; second, the formation of a large cerebellar abscess that required surgical drainage. This case is a rare example of the complications that are possible following radiotherapy to the head and the close follow-up that is required in patients.

  19. The role of 18F–NaF PET/CT in metastatic bone disease

    Directory of Open Access Journals (Sweden)

    Mine Araz

    2015-09-01

    Conclusion: Although further prospective clinical studies in specific cancer populations are indicated to set the place of 18F–NaF PET/CT in diagnostic scheme, the results of this pilot study from our country support the superiority of 18F–NaF PET/CT in investigation of bone metastasis over 99mTc-MDP bone scan and 18F-FDG PET/CT in various malignancies. 18F–NaF PET/CT is coming forward as a single step bone seeking study, considering all the advantages, but especially potential of detecting occult metastases and reliably directing patient management.

  20. Enhanced temporal resolution at cardiac CT with a novel CT image reconstruction algorithm: Initial patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Apfaltrer, Paul, E-mail: paul.apfaltrer@medma.uni-heidelberg.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Institute of Clinical Radiology and Nuclear Medicine, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoendube, Harald, E-mail: harald.schoendube@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Allmendinger, Thomas, E-mail: thomas.allmendinger@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Tricarico, Francesco, E-mail: francescotricarico82@gmail.com [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Department of Bioimaging and Radiological Sciences, Catholic University of the Sacred Heart, “A. Gemelli” Hospital, Largo A. Gemelli 8, Rome (Italy); Schindler, Andreas, E-mail: andreas.schindler@campus.lmu.de [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, PO Box 250322, 169 Ashley Avenue, Charleston, SC 29425 (United States); Vogt, Sebastian, E-mail: sebastian.vogt@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); Sunnegårdh, Johan, E-mail: johan.sunnegardh@siemens.com [Siemens Healthcare, CT Division, Forchheim Siemens, Siemensstr. 1, 91301 Forchheim (Germany); and others

    2013-02-15

    Objective: To evaluate the effect of a temporal resolution improvement method (TRIM) for cardiac CT on diagnostic image quality for coronary artery assessment. Materials and methods: The TRIM-algorithm employs an iterative approach to reconstruct images from less than 180° of projections and uses a histogram constraint to prevent the occurrence of limited-angle artifacts. This algorithm was applied in 11 obese patients (7 men, 67.2 ± 9.8 years) who had undergone second generation dual-source cardiac CT with 120 kV, 175–426 mAs, and 500 ms gantry rotation. All data were reconstructed with a temporal resolution of 250 ms using traditional filtered-back projection (FBP) and of 200 ms using the TRIM-algorithm. Contrast attenuation and contrast-to-noise-ratio (CNR) were measured in the ascending aorta. The presence and severity of coronary motion artifacts was rated on a 4-point Likert scale. Results: All scans were considered of diagnostic quality. Mean BMI was 36 ± 3.6 kg/m{sup 2}. Average heart rate was 60 ± 9 bpm. Mean effective dose was 13.5 ± 4.6 mSv. When comparing FBP- and TRIM reconstructed series, the attenuation within the ascending aorta (392 ± 70.7 vs. 396.8 ± 70.1 HU, p > 0.05) and CNR (13.2 ± 3.2 vs. 11.7 ± 3.1, p > 0.05) were not significantly different. A total of 110 coronary segments were evaluated. All studies were deemed diagnostic; however, there was a significant (p < 0.05) difference in the severity score distribution of coronary motion artifacts between FBP (median = 2.5) and TRIM (median = 2.0) reconstructions. Conclusion: The algorithm evaluated here delivers diagnostic imaging quality of the coronary arteries despite 500 ms gantry rotation. Possible applications include improvement of cardiac imaging on slower gantry rotation systems or mitigation of the trade-off between temporal resolution and CNR in obese patients.

  1. MicroCT evaluation of bone mineral density loss in human bones

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Liebert P.; Braz, Delson; Lopes, Ricardo T. [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia (COPPE). Lab. de Instrumentacao Nuclear]. E-mails: lnogueira@con.ufrj.br; Barroso, Regina C.; Oliveira, Luis F. [Universidade do Estado do Rio de Janeiro (UERJ), Rio de Janeiro, RJ (Brazil). Inst. de Fisica]. E-mail: cely@uerj.br

    2007-07-01

    Bone is a connective tissue largely composed of an organic protein, collagen and the inorganic mineral hydroxyapatite [Ca{sub 10}(PO{sub 4}){sub 6}OH{sub 2}], which combine to provide a mechanical and supportive role in the body. Depending on the orientation of collagen fibers, two types of bone can be distinguished: trabecular and cortical bone. Degree of mineralization is considered an important feature of bone quality. Changes in the degree of mineralization is generally due to osteoporosis, but many recent studies have already shown that alterations in degree of mineralization can occur due to a large variety of factors. The transmission X-ray microtomography is one of the most popular methods, which provides the spatial distribution of the total absorption coefficient inside the sample. The aim of this study was to investigate the suitability of using microCT as a supplementary tool for the diagnosis of the health status of human bones. Eleven samples were constructed simulating the physiological range of bone mineral density (BMD) found in cortical human bone. The samples represent healthy mixtures of swine compact bone dried at room temperature, powdered and mixed with fat (0 - 100 % by mass). The samples were imaged by a microfocus tube (Fein-Focus) with focal size of about 60 {mu}m ({+-}5%), and a CCD camera (0.143 mm pixel size) coupled with an intensifier tube with fluoroscope screen at the Nuclear Instrumentation Laboratory (COPPE/UFRJ), Brazil. The images were reconstructed and treated with suitable software developed at the Nuclear Instrumentation Laboratory. The mineral content in cortical bone is defined by the volume of dry, fat-free bone per unit bulk volume of the bone. The volumes were calculated from the bone density using the relationship between volume and density. The densities of fat and bone were taken to be 0.95 g.cm{sup -3} and 1.92 g.cm{sup -3} respectively. The correlation of the measured absorption coefficient with the mineral content

  2. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Odontologia. Dept. de Radiologia], e-mail: mgpcaval@usp.br; Kuruoshi, Marcia Etsuko [Universidade de Sao Paulo (USP), SP (Brazil). Hospital Universitario. Dept. de Radiologia

    2009-07-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  3. SUBJECTIVE TINNITUS AS FIRST PRESENTATION IN A PATIENT WITH METASTATIC LUNG CANCER IN TEMPORAL BONE-A CASE REPORT

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jing; WANG Hongtian; JIA Jingjie; XIAO Yueyong; SHI Huaiyin; YANG Weiyan

    2013-01-01

    Metastasis of lung cancer to the temporal bone is a very rare disease and subjective tinnitus as the present-ing symptom in these patients is even rarer. Here we report a case in which a 42-year-old male presented with subjective tinnitus of three months, with no pulmonary disease symptoms. Pure tone audiometry indi-cated moderate conductive deafness in left ear with an air-bone gap of 21.3 dB. HRCT temporal bone scan-ning indicated high-density shadows in the left epitympanic cavity, sinus tympani and mastoid cavity. Chron-ic otitis media with cholesteatoma was suspected and surgical treatment recommended. However, preopera-tive chest x-ray revealed high-density millet lesions scattered widely in both lungs. HRCT lung scanning confirmed the lungs lesions and indicated lung cancer. In order to determine correlations between the tempo-ral bone and pulmonary lesions, a CT-guided trans-mastoid aspiration biopsy and immunohistochemical study were conducted, which confirmed that the temporal bone lesion was metastatic from the lungs. The pa-tient was given a series of chemotherapy immediately and his tinnitus significantly improved after three months of treatment, with full recovery of his hearing and complete resolution of shadows in the mastoid cavity. Unfortunately, he subsequently developed multiple bone metastases in the 9th month and cerebral metastasis in the 18th month. Multiple organ failure resulted in death in 2.5 years.

  4. Post-Traumatic Bilateral Facial Paralysis Associated with Temporal Bone Fracture.

    Science.gov (United States)

    Habib, Syed Shahid; Al Rouq, Fawzia; Meo, Imran

    2015-10-01

    Bilateral traumatic facial paralysis is a very rare clinical condition. Loss of taste sensation, associated with bilateral traumatic paralysis, is even rarer and has not been well described in the literature. In this report, a 23-year old male, who developed bilateral facial paralysis with loss of taste sensation and hearing impairment, following a motor vehicle accident, is presented. He had initially presented with unconsciousness for about 2 hours after he sustained closed head injury after a motor vehicle accident. Initial Computed Tomography (CT) scans revealed a small epidural hematoma, right temporal bone fracture and air densities around the basal cistern. On the 4th day after trauma, he was noted to have incomplete closure of both eyes and was feeling difficulty with chewing and drooling of saliva. Electrodiagnostic testing confirmed the diagnosis of bilateral facial paralysis-House-Brackmann (HB) grade V. Electroneuronography (ENoG) showed degeneration of 90% nerve fibres bilaterally. The high-resolution CT scans showed bilateral temporal bone fractures. At 3 months of follow-up, the patient had partial recovery of facial nerve function bilaterally and improvement in HB classification to grade III and ENoG of 60% was observed.

  5. Temporal bone trauma and complications: computed tomography findings

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Ana Maria Doffemond; Gaiotti, Juliana Oggioni; Couto, Caroline Laurita Batista; Gomes, Natalia Delage; Diniz, Renata Lopes Furletti Caldeira; Motta, Emilia Guerra Pinto Coelho, E-mail: anadoffemond@yahoo.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil). Unit of Radiology and Imaging Diagnosis

    2013-03-15

    Most temporal bone fractures result from high-energy blunt head trauma, and are frequently related to other skull fractures or to polytrauma. Fractures and displacements of ossicular chain in the middle ear represent some of the main complications of temporal bone injury, and hence they will be more deeply approached in the present article. Other types of injuries include labyrinthine fractures, dural fistula, facial nerve paralysis and extension into the carotid canal. Computed tomography plays a fundamental role in the initial evaluation of polytrauma patients, as it can help to identify important structural injuries that may lead to severe complications such as sensorineural hearing loss, conductive hearing loss, dizziness and balance dysfunction, perilymphatic fistulas, facial nerve paralysis, vascular injury and others. (author)

  6. Malignancy rate of biopsied suspicious bone lesions identified on FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A.; Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Klerk, John M.H. de [Meander Medical Center, Department of Nuclear Medicine, Amersfoort (Netherlands); Heggelman, Ben G.F. [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Dubois, Stefan V. [Meander Medical Center, Department of Pathology, Amersfoort (Netherlands)

    2016-07-15

    To determine the malignancy rate of bone lesions identified on FDG PET/CT in patients who have undergone CT-guided biopsy because of the suspicion of malignancy. This single-centre retrospective study spanned eight consecutive years and included all patients who underwent both FDG PET/CT and CT-guided bone biopsy because of the suspicion of malignancy. The positive predictive value (PPV) for malignancy was calculated, and different patient and imaging characteristics were compared between malignant and benign bone lesions. Of 102 included patients with bone lesions that all showed FDG uptake exceeding mediastinal uptake, bone biopsy showed a malignant lesion in 91 patients, yielding a PPV for malignancy of 89.2 % (95 % CI 81.7 - 93.9 %). In the 94 patients with bone lesions that showed FDG uptake exceeding liver uptake, bone biopsy showed a malignant lesion in 83 patients, yielding a PPV for malignancy of 88.3 % (95 % CI 80.1 - 93.5 %). Higher age, bone marrow replacement of the lesion seen on CT, expansion of the lesion seen on CT, and presence of multifocal lesions on FDG PET/CT were significantly more frequent in patients with malignant lesions than in those with benign bone lesions (P = 0.044, P = 0.009, P = 0.015, and P = 0.019, respectively). Furthermore, there was a trend towards a higher incidence of cortical destruction (P = 0.056) and surrounding soft tissue mass (P = 0.063) in patients with malignant bone lesions. The PPV for malignancy of suspicious bone lesions identified on FDG PET/CT is not sufficiently high to justify changes in patient management without histopathological confirmation. Nevertheless, ancillary patient and imaging characteristics may increase the likelihood of a malignant bone lesion. (orig.)

  7. Diagnosis of bone metastases: a meta-analysis comparing {sup 18}FDG PET, CT, MRI and bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hui-Lin; Liu, Tao [Hospital of Soochow University, Department of Orthopaedics, Suzhou (China); Wang, Xi-Ming [Hospital of Soochow University, Department of Radiology, Suzhou (China); Xu, Yong [Public Health School of Soochow University, Department of Epidemiology and Biostatistics, Suzhou (China); Deng, Sheng-Ming [Department of Nuclear Medicine, The first affiliated hospital of Soochow University, Suzhou (China)

    2011-12-15

    To perform a meta-analysis to compare {sup 18}FDG PET, CT, MRI and bone scintigraphy (BS) for the diagnosis of bone metastases. Databases including MEDLINE and EMBASE were searched for relevant original articles published from January 1995 to January 2010. Software was used to obtain pooled estimates of sensitivity, specificity and summary receiver operating characteristic curves (SROC). 67 articles consisting of 145 studies fulfilled all inclusion criteria. On per-patient basis, the pooled sensitivity estimates for PET, CT, MRI and BS were 89.7%, 72.9%, 90.6% and 86.0% respectively. PET=MRI>BS>CT. (''=''indicated no significant difference, P > 0.05; ''>'' indicated significantly higher, P < 0.05). The pooled specificity estimates for PET, CT, MRI and BS were 96.8%, 94.8%, 95.4% and 81.4% respectively. PET = CT = MRI>BS. On per-lesion basis, the pooled sensitivity estimates for PET, CT, MRI and BS were 86.9%, 77.1%, 90.4% and 75.1% respectively. PET = MRI>BS>CT. The pooled specificity estimates for PET, CT, MRI and BS were 97.0%, 83.2%, 96.0% and 93.6% respectively. PET>MRI>BS>CT. PET and MRI were found to be comparable and both significantly more accurate than CT and BS for the diagnosis of bone metastases. (orig.)

  8. A metastatic glomus jugulare tumor. A temporal bone report

    Energy Technology Data Exchange (ETDEWEB)

    El Fiky, F.M.; Paparella, M.M.

    1984-01-01

    The clinicopathologic findings in the temporal bone of a patient with a highly malignant metastasizing glomus jugulare tumor are reported. The patient exhibited all the symptoms of primary malignant tumors of the ear, including facial paralysis, otorrhea, pain, hearing loss, tinnitus, dizziness, and vertigo. He was treated with cobalt irradiation followed by radium implant in the ear canal for a residual tumor; then a left-sided radical mastoidectomy was performed.

  9. Discrepancy of bone metastases between F-18 FDG PET/CT and bone scan in a patient with prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Jin; Kim, Chul Soo; Byun, Sung Su; Hyun, In Young [Inha University College of Medicine, Incheon (Korea, Republic of)

    2006-10-15

    We report the case of a 73-year-old man who had prostate cancer with bone metastases. Tc-99m HDP Whole body bone scan revealed multiple areas of increased bony uptake consistent with widespread bone metastases. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) demonstrated mild F-18 FDG uptake in the lymph nodes of neck, abdomen, and pelvis. However, abnormal F-18 FDG uptake was not seen in the skeletal system. Biopsy and immunohistochemical stains of left supraclavicular mass showed metastatic prostate adenocarcinoma. Currently, there are a few reported cases of F-18 FDG PET/CT evaluation of bone metastases in prostate cancer. We discuss the discrepancy between F-18 FDG PET/CT and bone scan in the detection of osseous metastases of prostate cancer.

  10. Temporal bone chondroblastoma with secondary aneurysmal bone cyst presenting as an intracranial mass with clinical seizure activity.

    Science.gov (United States)

    Stapleton, Christopher J; Walcott, Brian P; Linskey, Katy R; Kahle, Kristopher T; Nahed, Brian V; Asaad, Wael F

    2011-06-01

    Chondroblastomas are rare tumors that characteristically arise from the epiphyseal cartilage of long bones of the immature skeleton. Intracranial involvement is uncommon, though the squamous portion of the temporal bone is preferentially affected due to its cartilaginous origin. Patients with temporal bone chondroblastomas classically present with otologic symptoms, while primary neurological complaints are rare. In this report, we describe a 33 year-old man with a chondroblastoma of the temporal bone and an associated aneurysmal bone cyst constituting a large intracranial mass lesion who presented with new-onset seizure activity. We review issues relevant to the pathology and treatment of these lesions.

  11. Clinical application of multislice spiral CT for temporal bone and multiple post-processing reconstruction techniques for infant cochlear implantation%颞骨MSCT及多种后处理技术在婴幼儿人工耳蜗植入术中的临床应用

    Institute of Scientific and Technical Information of China (English)

    陈彩龙; 林美福; 周硕; 王恩成; 陈国宝; 陈文新

    2015-01-01

    Objective To investigate the clinical application value of multislice spiral CT (MSCT) for temporal bone and multiple post-processing reconstruction techniques for infant cochlear implantation.Methods Fifty preoperative patients and two postoperative patients with severe sensorineural hearing loss (SNHL) underwent high-resolution temporal bone MSCT.Double-threshold reconstruction,transparent imaging and three-dimensional fusion,double-oblique diameter multiplanar reconstruction,and curved planar reconstruction were used to measure the distance between the vertical facial nerve and external acoustic canal and the round window breadth,as well as analyze the inner ear structure.Results ①Out of 50 preoperative patients,7 showed inner ear malformations,9 presented chronic tympanomastoiditis,and 34 exhibited normal ear structure.The probability of inner ear malformations was 14.0%.Before cochlear implantation,the inner ear structure and ossicular chain were clearly observed in all the patients enrolled in this study.The distance between the vertical facial nerve and external acoustic canal was (0.33±0.057) cm on the right side and (0.33±0.068) cm on the left side.The round window breadth was (0.14±0.027) cm on the right side and (0.14±0.025) cm on the left side.②The electrodes and postoperative changes were clearly detected in two patients with cochlear implants.Conclusions Inner ear malformations were clearly shown by high-resolution temporal bone scanning in a number of SNHL patients.Multiple post-processing techniques can significantly obtain precise information on the temporal anatomical structure before cochlear implantation and provide accurate assessment of the operation.%目的 探讨颞骨多层螺旋CT(MSCT)及多种后处理技术在婴幼儿人工耳蜗植入术中的临床应用价值.方法 对50例术前和2例术后重度感音神经性耳聋(SNHL)患者行颞骨高分辨率CT平扫,应用双斜径多平面重建、面神经曲面重建、双

  12. High-resolution computed tomography of the temporal bone. Part 1.: normal anatomy; Kosc skroniowa w tomografii komputerowej wysokiej rozdzielczosci. Czesc 1.: anatomia prawidlowa

    Energy Technology Data Exchange (ETDEWEB)

    Grzegorzewski, M.; Boron, Z.; Burzynska-Makuch, M. [Katedra i Zaklad Radiologii i Diagnostyki Narzadowej, Akademia Medyczna, Bydgoszcz (Poland)

    1995-12-31

    Normal anatomy of the temporal bone in transverse and coronal sections was presented. CT studies were performed using high-resolution program. The images of an asymptomatic ear of 2 patients were selected from 68 cases examined on account of various otological diseases. All the sections showed as many as 68 anatomic structures. (author) 5 refs, 2 figs

  13. Percutaneous Bone Biopsies: Comparison between Flat-Panel Cone-Beam CT and CT-Scan Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Tselikas, Lambros, E-mail: lambros.tselikas@gmail.com; Joskin, Julien, E-mail: j.joskin@gmail.com [Gustave Roussy, Interventional Radiology Department (France); Roquet, Florian, E-mail: florianroquet@hotmail.com [Gustave Roussy, Biostatistics Department (France); Farouil, Geoffroy, E-mail: g.farouil@gmail.com [Gustave Roussy, Interventional Radiology Department (France); Dreuil, Serge, E-mail: serge.dreuil@gustaveroussy.fr [Gustave Roussy, Medical Physics Department (France); Hakimé, Antoine, E-mail: thakime@yahoo.com; Teriitehau, Christophe, E-mail: cteriitehau@me.com [Gustave Roussy, Interventional Radiology Department (France); Auperin, Anne, E-mail: anne.auperin@gustaveroussy.fr [Gustave Roussy, Biostatistics Department (France); Baere, Thierry de, E-mail: thierry.debaere@gustaveroussy.fr; Deschamps, Frederic, E-mail: frederic.deschamps@gustaveroussy.fr [Gustave Roussy, Interventional Radiology Department (France)

    2015-02-15

    PurposeThis study was designed to compare the accuracy of targeting and the radiation dose of bone biopsies performed either under fluoroscopic guidance using a cone-beam CT with real-time 3D image fusion software (FP-CBCT-guidance) or under conventional computed tomography guidance (CT-guidance).MethodsSixty-eight consecutive patients with a bone lesion were prospectively included. The bone biopsies were scheduled under FP-CBCT-guidance or under CT-guidance according to operating room availability. Thirty-four patients underwent a bone biopsy under FP-CBCT and 34 under CT-guidance. We prospectively compared the two guidance modalities for their technical success, accuracy, puncture time, and pathological success rate. Patient and physician radiation doses also were compared.ResultsAll biopsies were technically successful, with both guidance modalities. Accuracy was significantly better using FP-CBCT-guidance (3 and 5 mm respectively: p = 0.003). There was no significant difference in puncture time (32 and 31 min respectively, p = 0.51) nor in pathological results (88 and 88 % of pathological success respectively, p = 1). Patient radiation doses were significantly lower with FP-CBCT (45 vs. 136 mSv, p < 0.0001). The percentage of operators who received a dose higher than 0.001 mSv (dosimeter detection dose threshold) was lower with FP-CBCT than CT-guidance (27 vs. 59 %, p = 0.01).ConclusionsFP-CBCT-guidance for bone biopsy is accurate and reduces patient and operator radiation doses compared with CT-guidance.

  14. Comparison of bone histomorphometry and μCT for evaluating bone quality in tail-suspended rats

    Science.gov (United States)

    Sun, Lian-Wen; Huang, Yun-Fei; Wang, Ying; Luan, Hui-Qin; Fan, Yu-Bo

    2014-10-01

    Astronauts often suffer from microgravity-induced osteoporosis due to their time in space. Bone histomorphometry, the 'gold standard' technique for detecting bone quality, is widely used in the evaluation of osteoporosis. This study investigates whether μCT has the same application value as histomorphometry in the evaluation of weightlessness-induced bone loss. A total of 24 SD rats were distributed into three groups (n = 8, each): tail-suspension (TS), TS plus active exercise (TSA), and control (CON). After 21 days, bone mineral density (BMD) was measured by dual energy X-ray absorptiometry (DXA) and μCT, and microstructure was measured by μCT and histomorphometry. BMD was found to have decreased significantly in TS and TSA compared with the CON group. The results of the μCT measurements showed that a change in BMD mainly occurred in the trabecular bone, and the trabecular BMD increased significantly in the TSA compared with the TS group. The comparison of μCT and histomorphometry showed that TS led to a significant decrease in bone volume (BV/TV), trabecular thickness (Tb.Th) and trabecular number (Tb.N), and it led to an increase in trabecular separation (Tb.Sp). However, active exercise can prevent these changes. Significant differences in most parameters between TSA and CON were found by μCT but not by histomorphometry. Additionally, the parameters of these two methods are highly correlated. Therefore, the application value of μCT is as good as histomorphometry and DXA in the diagnosis of weightlessness-induced osteoporosis and is even better in evaluating the efficacy of exercise.

  15. HT-BONE: a graphical user interface for the identification of bone profiles in CT images via extended Hough transform

    Science.gov (United States)

    Campi, Cristina; Perasso, Annalisa; Beltrametti, Mauro C.; Piana, Michele; Sambuceti, Gianmario; Massone, Anna Maria

    2016-03-01

    It has been recently proved that the computational analysis of X-ray Computed Tomography (CT) images allows clinicians to assess the alteration of compact bone asset due to hematological diseases. HT-BONE implements a new method, based on an extension of the Hough transform (HT) to a wide class of algebraic curves, for accurately measuring global and regional geometric properties of trabecular and compact bone districts. In the case of CT/PET analysis, the segmentation of the CT images provides masks for Positron Emission Tomography (PET) data, extracting the metabolic activity in the region surrounded by compact bone tissue. HT-BONE offers an intuitive, user-friendly, Matlab-based Graphical User Interface (GUI) for all input/output procedures and the automatic managing of the segmentation process also from non-expert users: the CT/PET data can be loaded and browsed easily and the only pre-preprocessing required from the user is the drawing of Regions Of Interest (ROIs) around the bone districts under consideration. For each bone district, specific families of curves, whose reliability has been already tested in previous works, is automatically selected for the recognition task via HT. As output, the software returns masks of the segmented compact bone regions, images of the Standard Uptake Values (SUV) in the masked regions of PET slices, and the values of the parameters in the curve equations utilized in the HT procedure. This information can be used for all pathologies and clinical conditions for which the alteration of the compact bone asset or bone marrow distribution plays a crucial role.

  16. PET/CT versus bone marrow biopsy in the initial evaluation of bone marrow infiltration in various pediatric malignancies.

    Science.gov (United States)

    Zapata, Claudia P; Cuglievan, Branko; Zapata, Catalina M; Olavarrieta, Raquel; Raskin, Scott; Desai, Kavita; De Angulo, Guillermo

    2017-09-13

    Accurate staging is essential in the prognosis and management of pediatric malignancies. Current protocols require screening for marrow infiltration with bone marrow biopsy (BMB) as the gold standard. Positron emission tomography-computed tomography (PET-CT) is commonly used to complete the staging process and can also be used to evaluate marrow infiltration. To compare PET-CT and BMB in the initial evaluation of bone marrow infiltration in pediatric cancers. We retrospectively reviewed new cases of EWS, rhabdomyosarcoma, neuroblastoma, and lymphoma diagnosed between January 2009 and October 2014. Each case had undergone both PET-CT and BMB within 4 weeks without treatment in the interval between screening modalities. We reviewed 69 cases. Bone marrow infiltration was demonstrated in 34 cases by PET-CT and in 18 cases by BMB. The sensitivity and negative predictive value of PET-CT were both 100%. Interestingly, the cases in which infiltration was not detected on BMB had an abnormal marrow signal on PET-CT focal or distant to iliac crest. PET-CT has a high sensitivity when assessing marrow infiltration in pediatric malignancies. Advances in radiologic modalities may obviate the use of invasive, painful, and costly procedures like BMB. Furthermore, biopsy results are limited by insufficient tissue or the degree of marrow infiltration (diffuse vs. focal disease). PET-CT can improve the precision of biopsy when used as a guiding tool. This study proposes the use of PET-CT as first-line screening for bone marrow infiltration to improve the accuracy of staging in new diagnoses. © 2017 Wiley Periodicals, Inc.

  17. X-ray CT high-density artefact suppression in the presence of bones

    Energy Technology Data Exchange (ETDEWEB)

    Wei Jikun [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Chen Laigao [BioImaging Center of Emphasis, Pfizer Global Research and Development, 2800 Plymouth RD, Ann Arbor, MI 48105 (United States); Sandison, George A [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Liang Yun [Department of Radiology, Indiana University Medical School, Indianapolis, IN 46202 (United States); Xu, Lisa X [School of Mechanical Engineering, 585 Purdue Mall, West Lafayette, IN 47907-2040 (United States)

    2004-12-21

    This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy)

  18. Comparative Study of Temporal Bone High-resolution CT and Intra-operative Findings in Patients with Traumatic Facial Nerve Paralysis%外伤性面瘫患者的颞骨高分辨率CT表现及其术中对照研究

    Institute of Scientific and Technical Information of China (English)

    袁辉; 金延方; 岳云龙; 李健东; 赵亮

    2013-01-01

    Purpose To investigate the value of the temporal bone high-resolution CT (HRCT) in traumatic facial paralysis. Materials and Methods HRCT with cross-sectional scanning and multi-planar reformation (MPR) was applied to 21 ears in patients with traumatic facial paralysis, and the imaging manifestations were retrospectively analyzed according to the surgical results. Results In the 21 ears, there were 15 ears with longitudinal fractures, 3 ears with transverse fractures, 3 ears with mixed type. 32 segments of facial nerve canal involvement were observed on HRCT, fracture involved in the facial nerve canal and the tympanic segment of the geniculate ganglion segment in 8 ears, only involved in the geniculate ganglion segment in 8 ears, involved in the labyrinthine segment and the geniculate ganglion segment in 2 ears, only involved in the tympanic segment in 1 ear, involved in the labyrinthine segment 1 ear, and the tympanic segment and after knee segment involvement 1 ear. 49 segments of facial nerve were involved in surgery. Compared with surgical results, HRCT had the full agreement with all segments involvement in 3 ears (3/21), 1 segment involvement in 10 ears (10/21), 2 segments involvement in 8 ears (8/21). Conclusion Temporal bone HRCT can underestimate the extent of damage, and provide important information for the clinical treatment of traumatic paralysis. However, HRCT will underestimate the damage extent of facial nerve canal compared with the surgical results, especially in post-knee segment and mastoid segment damage.%  目的探讨颞骨高分辨率CT(HRCT)在外伤性面瘫中的应用价值。资料与方法对外伤性面瘫患者的21侧耳行HRCT横断面扫描及多平面重组(MPR),对照其手术结果回顾性分析影像学表现。结果21耳中,纵行骨折15耳,横行骨折3耳,混合型3耳。HRCT共显示32段面神经管受累,其中,骨折同时累及面神经管膝状神经节段及鼓室段8耳,

  19. Temporal bone characterization and cochlear implant feasibility in the common marmoset (Callithrix jacchus).

    Science.gov (United States)

    Johnson, Luke A; Della Santina, Charles C; Wang, Xiaoqin

    2012-08-01

    The marmoset (Callithrix jacchus) is a valuable non-human primate model for studying behavioral and neural mechanisms related to vocal communication. It is also well suited for investigating neural mechanisms related to cochlear implants. The purpose of this study was to characterize marmoset temporal bone anatomy and investigate the feasibility of implanting a multi-channel intracochlear electrode into the marmoset scala tympani. Micro computed tomography (microCT) was used to create high-resolution images of marmoset temporal bones. Cochlear fluid spaces, middle ear ossicles, semicircular canals and the surrounding temporal bone were reconstructed in three-dimensional space. Our results show that the marmoset cochlea is ∼16.5 mm in length and has ∼2.8 turns. The cross-sectional area of the scala tympani is greatest (∼0.8 mm(2)) at ∼1.75 mm from the base of the scala, reduces to ∼0.4 mm(2) at 5 mm from the base, and decreases at a constant rate for the remaining length. Interestingly, this length-area profile, when scaled 2.5 times, is similar to the scala tympani of the human cochlea. Given these dimensions, a compatible multi-channel implant electrode was identified. In a cadaveric specimen, this electrode was inserted ¾ turn into the scala tympani through a cochleostomy at ∼1 mm apical to the round window. The depth of the most apical electrode band was ∼8 mm. Our study provides detailed structural anatomy data for the middle and inner ear of the marmoset, and suggests the potential of the marmoset as a new non-human primate model for cochlear implant research.

  20. Langerhans' Cell Histiocytosis (Histiocytosis X) of the Temporal Bone

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Objectives Langerhans' Cell histiocytosis (LCH) is a rare disease, which remains poorly understood and whose cellular origin remains unknown. To increase understanding of temporal bone LCH, it is necessary to study recent advances in the diagnosis and treatment of this disease. Methods The long term(5 to 30 years) results of 21 temporal bone LCH cases treated between 1973 and 2003 were reviewed. Surgery, radiotherapy,pharmacologic therapy or a combination of these treatments were employed in these cases. Results Eighteen patients were cured (18/21, 85%). Six patients developed residual diabetes insipidus (DI) and dwarfism (28%).Three patients died (14%). Conclusions The Alessi classification system for LCH based on the extent of disease accurately predicts prognosis and is a useful guide in selecting treatment methodologies. X-ray, computed tomography and magnetic resonance imaging have proved useful in defining the extent of osseous and soft tissue diseases. Diagnosis of LCH is based on clinical presentations, radiographic findings and histopathological results.Surgery and radiotherapy are the main treatment modalities. Pharmacologic therapy should be used in patients with aggressive, disseminate, and refractory lesions. LCH has a predilection for children and prognosis depends on age and extent of vital organ involvement.

  1. Diagnostic performance of [18F] FDG PET-CT compared to bone scintigraphy for the detection of bone metastases in lung cancer patients.

    Science.gov (United States)

    Rodrigues, Margarida; Stark, Hannes; Rendl, Gundula; Rettenbacher, Lukas; Datz, Lidwina; Studnicka, Michael; Pirich, Christian

    2016-03-01

    Accurate staging of lung cancer is essential for effective patient management and selection of appropriate therapeutic strategy. The aim of this paper was to compare the value of bone scintigraphy and FDG PET-CT for detecting bone metastases in lung cancer patients and the impact of these modalities in disease staging. One hundred sixty-four lung cancer patients who had undergone both FDG PET-CT and bone scintigraphy within 14 days were included into this study. The analysis of FDG PET-CT and bone scintigraphy was carried out patient- and lesion-based. One hundred twenty-one patients were negative and 43 patients positive for bone metastases. FDG PET-CT found bone metastases in 42/43 patients and bone scintigraphy in 38/43 patients. Sensitivity, specificity and accuracy of FDG PET-CT and bone scintigraphy for detecting bone metastases were 97.7%, 100% and 99.4%, and 87.8%, 97.5% and 94.2%, respectively. FDG PET-CT identified 430 bone metastases and bone scintigraphy 246 bone metastases. Skull was the only region where bone scintigraphy identified more lesions than FDG PET-CT. Based on both scintigraphic modalities disagreement concerning disease stage was found in 3 patients. FDG PET-CT yielded a higher sensitivity, specificity and accuracy than bone scintigraphy for identifying bone metastases in lung cancer patients. FDG PET-CT thus can be recommended for initial staging of lung cancer patients without applying bone scintigraphy for the detection of bone metastases.

  2. Accuracy of trabecular bone microstructural measurement at planned dental implant sites using cone-beam CT datasets

    NARCIS (Netherlands)

    Ibrahim, N.; Parsa, A.; Hassan, B.; van der Stelt, P.; Aartman, I.H.A.; Wismeijer, D.

    2014-01-01

    Objective Cone-beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the system's limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CTCT). Materials

  3. Osteoradionecrosis of the temporal bone with cancer of the middle ear. A case report

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Katsunori; Sakai, Makoto [Chigasaki Central Hospital, Kanagawa (Japan); Shinkawa, Atsushi

    1999-12-01

    Osteoradionecrosis of the temporal bone may occur as a result of radiation therapy for head and neck carcinomas or brain tumors. A 64-year-old female received radiation therapy for squamous cell carcinoma of the middle ear 20 years ago, and then she developed osteoradionecrosis of the temporal bone. The patient underwent extensive debridement with removal of sequestrations in the temporal bone and adjacent areas, and abscess drainage. Her postoperative course was satisfactory and there was no progression of the disease. (author)

  4. Primary aneurysmal bone cyst of the petrous temporal bone: A case report and review of literature

    Science.gov (United States)

    Sharma, Mayur; Velho, Vernon; Kharosekar, Hrushikesh

    2016-01-01

    Aneurysmal bone cyst (ABC) arising in the petrous portion of the temporal bone is a rare entity with only five such reported cases in the literature. We report the case of a 28-year-old man who presented with a tender swelling in the right preauricular region with right ear discharge and conductive hearing loss of 4 years' duration. Computed tomography and Magnetic Resonance imaging showed a destructive lesion in the right petrous bone with cavitation consistent with the diagnosis of ABC. Gross total resection of the lesion was achieved and diagnosis was confirmed histologically. The patient had no recurrence at 12 months of follow-up. This report presents the unusual location of an uncommon bony tumor with a review of its clinical, radiological, and histopathological features as well as the treatment modalities available.

  5. Collar Osteophytes Mimicking Osteonecrosis in Planar Bone Scintigraphy and Usefulness of SPECT/CT Images.

    Science.gov (United States)

    Juang, Jr-Jian; Chen, Yi-Hsing; Tsai, Shih-Chuan; Lin, Wan-Yu

    2017-03-01

    The use of prednisolone is one major risk factor for osteonecrosis in patients with systemic lupus erythematosus. Bone scintigraphy can be a diagnostic tool for early diagnosis. We present a case who had collar osteophytes at the bilateral femoral heads, which mimicked osteonecrosis in the planar bone scintigram. An SPECT/CT scan avoided this pitfall and increased the diagnostic accuracy for osteonecrosis.

  6. Value and limits of μ-CT for nondemineralized bone tissue processing.

    Science.gov (United States)

    Draenert, Miriam Esther; Draenert, Alice Irène; Forriol, Francisco; Cerler, Michael; Kunzelmann, Karl-Heinz; Hickel, Reinhard; Draenert, Klaus

    2012-04-01

    An experimental approach was performed on 20 giant rabbits to establish the possibilities and limitations of μ-CT for routine processing of nondemineralized bone tissue. Hydroxyapatite (HA) or β-tricalciumphosphate (β-TCP) bead implants or a melange of both, microchambered and solid, were implanted into a standardized and precise defect in the patellar groove. The bone-healing phase was chosen for the histology considering 1 or 2 days, and 2, 3, and 6 weeks. Normal X-ray and μ-CT were applied on all specimens; five specimens in the 6-week stage were additionally processed according to the full range of conventional nondemineralized bone processing methods. μ-CT increased the possibilities of nondemineralized histology with respect to bone morphometry and a complete sequence of sections, thus providing a complete analysis of the bone response. μ-CT was limited in differentiating bone quality, cell analyses, and mineralization stages. The investigation based on normal X-rays is limited to defining integration and excluding the fibrous and bony encapsulation of loose implants. μ-CT allows a 3D evaluation of newly formed bone which is clearly marked against the ceramic implant. It does not allow, however, for the differentiation between woven and lamellar bone, the presentation of the canalicular lacunar system, or on the cell level, revealing canaliculi or details of the mineralization process which can be documented by high-resolution microradiography. Titer dynamics of bone formation remains the domain of polychromatic sequential labeling. The complete sequence of μ-CT slices enhances the possibilities for routine histology, tremendously allowing to the focus on detail histology to topographically well-defined cuts, thus providing more precise conclusions which take into consideration the whole implant.

  7. Bone SPECT/CT detection of a sequestrum in chronic-infected nonunion of the tibia

    DEFF Research Database (Denmark)

    Madsen, Jan L

    2008-01-01

    Abstract: Sequestra are dead pieces of bone most often seen in long bones affected with prior or current infection. In addition to antibiotic therapy, chronic osteomyelitis with sequestration requires surgical debridement for cure. The author presents a case of tibial fracture associated with chr......Abstract: Sequestra are dead pieces of bone most often seen in long bones affected with prior or current infection. In addition to antibiotic therapy, chronic osteomyelitis with sequestration requires surgical debridement for cure. The author presents a case of tibial fracture associated...... with chronic osteomyelitis, nonunion, and the presence of a sequestrum that was detected by bone SPECT/CT.  ...

  8. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast....... The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p .... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro...

  9. System for the analysis of whole-bone strength from helical CT images

    Science.gov (United States)

    Camp, Jon J.; Karwoski, Ronald A.; Stacy, Mahlon C.; Atkinson, Elizabeth J.; Khosla, Sundeep; Melton, L. Joseph; Riggs, B. Lawrence; Robb, Richard A.

    2004-04-01

    Osteoporosis affects an estimated 44 million Americans. This condition results from bone loss, but the measured change in bone mass does not fully account for the marked decrease in whole-bone structural integrity seen in osteoporosis. In order to study structural changes in bone mineral distribution due to normal ageing and osteoporosis, we have developed a method for progressive analysis of whole-bone mechanical integrity from helical CT images. The system provides rapid semi-automated alignment of femur and vertebrae volume images into standard anatomic reference planes, and calculates bone mineral density in any selected 3D sections of bone. Mineral density measures are obtained using both full-width-half-max contours and threshold-derived masks, and are obtained for cortical bone and trabecular bone separately. Biomechanical properties of the bone cross-section are also assessed, including the 2-D bending moment of the cortical bone region and the integrated flexural rigidity of the cortical region or whole-bone region in arbitrary planes. This method facilitates progressive refinement of the analysis protocol by separating the labor-intensive alignment and landmark selection process from the analysis process. As the analysis protocol evolves to include new measures, previously analyzed images can be automatically reanalyzed, using the image regions originally specified. Initial results show inverse correlation of indices of biomechanical bone strength with age, greater loss of bone strength in the lumbar spine than in the femoral neck, and more trabecular than cortical bone loss at both sites.

  10. Diagnosis of pituitary adenomas by bone window CT. A comparative study with hypocycloidal tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, S.; Sato, O.; Tsuchita, H.; Nakagaki, Y.; Tsuruta, J. (Sapporo Medical Coll. (Japan))

    1981-02-01

    The CT scan is useful for the diagnosis of pituitary adenomas when they are well enhanced and show remarkable suprasellar extension. However, the deformity or the destruction of the sella turcica by pituitary adenomas is not well demonstrated by the conventional CT scan because of the artifacts or the partial volume effect elicited by the surrounding bony structures. To overcome these difficulties, the authors have developed the bone window CT scan, which demonstrates not only the soft tissue of the tumor, but also the bony changes of the sella turcica. The bone-window CT scan means a CT scan by the reverse-mode-display method, with a window width of 400 and a window level of 100. We analysed 36 cases of the sella turcica in pituitary adenomas by the bone-window CT scan in both axial and coronal sections and compared the results with those by hypocycloidal tomography. From the deformities of the sella turcica, we classified five types of sellar changes in pituitary adenomas. The bone window CT scan proved to be useful for the detection of not only the tumor mass but also the deformities of the sella. From the findings of the sellar deformities, the intrasellar location and the mode of extrasellar extension of the pituitary adenomas were defined. But the disadvantage of the bone window CT scan lies in the inaccurate delineation of the tumor extension into the sphenoid sinus or upward to suprasellar area and in the poor diagnostic value for pituitary microadenomas. These disadvantages will be supplemented by hypocycloidal tomography or conventional enhanced CT scan.

  11. Normal SUV values measured from NaF18- PET/CT bone scan studies.

    Directory of Open Access Journals (Sweden)

    Aung Zaw Win

    Full Text Available Cancer and metabolic bone diseases can alter the SUV. SUV values have never been measured from healthy skeletons in NaF18-PET/CT bone scans. The primary aim of this study was to measure the SUV values from normal skeletons in NaF18-PET/CT bone scans.A retrospective study was carried out involving NaF18- PET/CT bone scans that were done at our institution between January 2010 to May 2012. Our excluding criteria was patients with abnormal real function and patients with past history of cancer and metabolic bone diseases including but not limited to osteoporosis, osteopenia and Paget's disease. Eleven studies met all the criteria.The average normal SUVmax values from 11 patients were: cervical vertebrae 6.84 (range 4.38-8.64, thoracic vertebrae 7.36 (range 6.99-7.66, lumbar vertebrae 7.27 (range 7.04-7.72, femoral head 2.22 (range 1.1-4.3, humeral head 1.82 (range 1.2-2.9, mid sternum 5.51 (range 2.6-8.1, parietal bone 1.71 (range 1.3-2.4.According to our study, various skeletal sites have different normal SUV values. SUV values can be different between the normal bones and bones with tumor or metabolic bone disease. SUV can be used to quantify NaF-18 PET/CT studies. If the SUV values of the normal skeleton are known, they can be used in the characterization of bone lesions and in the assessment of treatment response to bone diseases.

  12. MRI and brain spect findings in patients with unilateral temporal lobe epilepsy and normal CT scan

    Directory of Open Access Journals (Sweden)

    P.G. Carrilho

    1994-06-01

    Full Text Available 26 patients with temporal lobe epilepsy clinically documented by several abnormal interictal surface EEGs with typical unitemporal epileptiform activity and a normal CT scan were studied. Interictal99mTC HMPAO brain SPECT and MRI were performed in all subjects. Abnormalities were shown in 61.5% of MRI (n=16 and 65.4% of SPECT (n=17. Hippocampal atrophy associated to a high signal on T2-weighted MRI slices suggesting mesial temporal sclerosis was the main finding (n=12; 75% of abnormal MRI. MRI correlated well to surface EEG in 50% (n=13. There was also a good correlation between MRI and SPECT in 30.7% (n=8. SPECT and EEG were in agreement in 57.7% (n=l5. MRI, SPECT and EEG were congruent in 26.9% (n=7. These results support the usefulness of interictal brain SPECT and MRI in detecting lateralized abnormalities in temporal lobe epilepsy. On the other hand, in two cases, interictal SPECT correlated poorly with surface EEG. This functional method should not be used isolately in the detection of temporal lobe foci. MRI is more useful than CT as a neuroimaging technique in temporal lobe epilepsy. It may detect small structural lesions and mesial temporal lobe sclerosis which are not easily seen with traditional CT scanning.

  13. Problems of laser vibrometry of temporal bone specimens

    Science.gov (United States)

    Zahnert, Thomas; Vogel, Uwe; Hofmann, Gert; Huettenbrink, Karl-Bernd

    1996-08-01

    Laser vibrometry became a well-established method for vibration detection of solids. By the means of laser Doppler interferometry it is possible to obtain information about displacement and velocity of the system under test. This approach allows the non-contact measurement of small vibrations, and is therefore capable of investigating vibration response of the middle ear ossicles or tympanic membrane due to sound simulation. There have been investigated 20 fresh human temporal bone specimens. Various components related to the sound transmission due to acoustic or mechanic stimulation have been measured by a commercial laser vibrometer (OFV3000 + OFV302/Polytec). Data acquisition, signal processing and test signal generation have been provided by a signal analyzer B&K3550/Bruel&Kjaer or integrated into a Notebook PC. The samples became prepared to allow laser beam access to the regions of interest. Generally our experiments show the capability of laser vibration measurements of the temporal bone specimen for middle ear sound transmission investigations. But the complexity is limiting that method unfortunately. 1D detection could represent insufficient information about the acoustic transmission characteristics only. The request of possibly 3D scanning is limited by anatomic conditions, e.g., according to the narrowness of the tympanic cavity. Nevertheless, for specific problems, e.g., investigation of spatially resolved tympanic membrane vibration characteristics, laser vibrometry performs a unique and high-sensitive approach. After removing the external ear canal different, well-defined points of the tympanic membrane surface have been manually scanned by the open laser beam. Particular care has been taken of the problem of perpendicular beam incidence, in order to detect identical vector components of the vibration amplitude. Laser vibrometry becomes suitable for functional investigation of the vibrating system `ear' influenced by boundary condition changes too

  14. Multimodal target correction by local bone registration: a PET/CT evaluation.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Weitzel, Thilo; Klaeser, Bernd; Krause, Thomas; Nolte, Lutz-Peter; Weber, Stefan; Reyes, Mauricio

    2010-01-01

    PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.

  15. Segmentation of multiple knee bones from CT for orthopedic knee surgery planning.

    Science.gov (United States)

    Wu, Dijia; Sofka, Michal; Birkbeck, Neil; Zhou, S Kevin

    2014-01-01

    Patient-specific orthopedic knee surgery planning requires precisely segmenting from 3D CT images multiple knee bones, namely femur, tibia, fibula, and patella, around the knee joint with severe pathologies. In this work, we propose a fully automated, highly precise, and computationally efficient segmentation approach for multiple bones. First, each bone is initially segmented using a model-based marginal space learning framework for pose estimation followed by non-rigid boundary deformation. To recover shape details, we then refine the bone segmentation using graph cut that incorporates the shape priors derived from the initial segmentation. Finally we remove overlap between neighboring bones using multi-layer graph partition. In experiments, we achieve simultaneous segmentation of femur, tibia, patella, and fibula with an overall accuracy of less than 1mm surface-to-surface error in less than 90s on hundreds of 3D CT scans with pathological knee joints.

  16. Processing of microCT implant-bone systems images using Fuzzy Mathematical Morphology

    Science.gov (United States)

    Bouchet, A.; Colabella, L.; Omar, S.; Ballarre, J.; Pastore, J.

    2016-04-01

    The relationship between a metallic implant and the existing bone in a surgical permanent prosthesis is of great importance since the fixation and osseointegration of the system leads to the failure or success of the surgery. Micro Computed Tomography is a technique that helps to visualize the structure of the bone. In this study, the microCT is used to analyze implant-bone systems images. However, one of the problems presented in the reconstruction of these images is the effect of the iron based implants, with a halo or fluorescence scattering distorting the micro CT image and leading to bad 3D reconstructions. In this work we introduce an automatic method for eliminate the effect of AISI 316L iron materials in the implant-bone system based on the application of Compensatory Fuzzy Mathematical Morphology for future investigate about the structural and mechanical properties of bone and cancellous materials.

  17. Micro-CT analyses of historical bone samples presenting with osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Lamm, C.; Pietschmann, P. [Medical University Vienna (MUV), Department of Pathophysiology and Allergy Research, Center for Pathophysiology, Infectiology and Immunology, Vienna (Austria); Dockner, M.; Weber, G.W. [University of Vienna, Department of Anthropology, Vienna (Austria); University of Vienna, Core Facility for Micro-Computed Tomography, Vienna (Austria); Pospischek, B.; Winter, E.; Patzak, B. [Museum of Natural History (NHM), Collection of Anatomical Pathology in the Madhouse Tower, Vienna (Austria); Pretterklieber, M. [Medical University of Vienna (MUV), Department of Applied Anatomy, Vienna (Austria)

    2015-10-15

    Osteomyelitis is an inflammation of the bone marrow mainly caused by bacteria such as Staphylococcus aureus. It typically affects long bones, e.g. femora, tibiae and humeri. Recently micro-computed tomography (μCT) techniques offer the opportunity to investigate bone micro-architecture in great detail. Since there is no information on long bone microstructure in osteomyelitis, we studied historic bone samples with osteomyelitis by μCT. We investigated 23 femora of 22 individuals suffering from osteomyelitis provided by the Collection of Anatomical Pathology, Museum of Natural History, Vienna (average age 44 ±19 years); 9 femora from body donors made available by the Department of Applied Anatomy, Medical University of Vienna (age range, 56-102 years) were studied as controls. Bone microstructure was assessed by μCT VISCOM X 8060 II with a minimal resolution of 18 μm. In the osteomyelitic femora, most prominent alterations were seen in the cortical compartment. In 71.4 % of the individuals with osteomyelitis, cortical porosity occurred. 57.1 % of the individuals showed cortical thinning. In 42.9 % trabecularisation of cortical bone was observed. Osteomyelitis is associated with severe alterations of cortical bone structure otherwise typically observed at old age such as cortical porosity and cortical thinning. (orig.)

  18. Bone marrow trephine biopsy in Hodgkin's lymphoma. Comparison with PET-CT scan in 65 patients.

    Science.gov (United States)

    Lakhwani, Sunil; Cabello-García, Dolores; Allende-Riera, Ana; Cárdenas-Negro, Carlos; Raya, José María; Hernández-Garcia, Miguel T

    2017-08-29

    To compare bone marrow biopsy (BMB) and PET/CT in detecting bone marrow involvement in Hodgkin's lymphoma MATERIAL AND METHODS: Retrospective analysis of 65 patients with both tests in the initial staging or in relapse with special attention to the PET/CT uptake pattern. In 3 patients (4.6%), the BMB showed bone marrow involvement with the PET/CT being positive in them all: 2 with diffuse+multifocal pattern and one diffuse only. In 11 additional patients (total 14/65, 21%), bone marrow involvement was diagnosed by PET/CT because bone marrow uptake was above hepatic one. The pattern was focal only in 2 cases, multifocal in 5, diffuse in 3 and diffuse+multifocal in one. In these last 4 cases the BMB showed an unspecific myelopathy. PET/CT detects all cases with BMB affected and many that escape to biopsy, however when the uptake pattern is diffuse it could be by involvement or reactive hyperplasia and in those cases the BMB should be done. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  19. CT of meningiomas on the posterior surface of the petrous bone

    Energy Technology Data Exchange (ETDEWEB)

    Valavanis, A.; Schubiger, O.; Hayek, J.; Pouliadis, G.

    1981-11-01

    A detailed analysis of the CT findings in 16 surgically verified cases of meningioma of the posterior surface of the petrous bone is presented. The results indicate that a correct preoperative diagnosis is possible in almost every case. Frequently occuring specific CT criteria for meningioma of the posterior surface of the petrous bone include: hyperdense, homogeneously enhancing, extra-axial, CPA mass; inverse relationship between precontrast attenuation value and degree of contrast enhancement of the tumor; oval shape; obtuse angle between lateral tumor border and posterior surface of petrous bone, and evidence of transcisternal supratentorial tumor extension. Infrequently occuring specific CT criteria include: tumor calcification; hyperostosis or exostosis of the posterior surface of the petrous bone; a comma-shaped tumor configuration in cases with transcisternal tumor extension and evidence of transtentorial tumor extension. Oxygen CT cisternography is the most sensitive and reliable technique for detecting small tumors. The CT differential diagnosis of meningioma of the posterior surface of the petrous bone is discussed.

  20. Synchrotron μCT Imaging of Bone, Titanium implants and Bone Substitutes -a Systematic Review of the Literature

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Pinholt, Else Marie

    2014-01-01

    examinations, SRμCT is considered as a gold standard to image trabecular bone microarchitecture since it is possible in a 3D manner to visualize fine structural elements within mineralized tissue such as osteon boundaries, rods and plates structures, cement lines, and differences in mineralization...

  1. Statistical model estimating the occurrence of otitis media from temporal bone pneumatization

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N; Rasmussen, N

    1994-01-01

    In order to investigate the relationship between the pneumatization of temporal bones and the occurrence of otitis media in Greenlandic Inuit, 36 Greenlandic Inuit were examined by radiography of the temporal bones. The pneumatized cell area was measured planimetrically. All subjects answered a q...

  2. Histology of sheep temporal bone A histologia do osso temporal do ovino

    Directory of Open Access Journals (Sweden)

    Hormy Biavatti Soares

    2011-06-01

    Full Text Available Previous studies suggest that there is an excellent correlation between the morphology and dimensions of ear structures in sheep and human beings. AIM: To analyze and describe the histology of structures inside the temporal bone in sheep. MATERIAL AND METHODS: A total of 307 slides obtained from vertical and horizontal sections of the temporal bone of eight sheep were analyzed. Structures were classified as similar or not similar to human structures, based on cellularity and histological architecture parameters. STUDY DESIGN: Experimental. RESULTS: The study revealed similarities between sheep and humans in terms of type of epithelium, bone component, spaces in the auditory meatus, in addition to a marked histological resemblance of cellularity and that of the structures surrounding the ear. The main differences observed were the presence of an anatomic bulla, the absence of aeration in the mastoid and the inferior opening of the hypotympanum into the bulla in sheep. CONCLUSION: Based on these observations, it is possible to conclude that sheep represent an adequate option for training and research in otologic surgery.Resultados prévios apontam para uma ótima correlação entre a morfologia e as dimensões das estruturas anatômicas de ovelhas e seres humanos. OBJETIVO: Analisar e descrever a histologia das estruturas que compõem o osso temporal do ovino. MATERIAL E MÉTODO: Um total de 307 lâminas obtidas a partir de secções verticais e horizontais do osso temporal de oito ovelhas foi analisado. As estruturas foram caracterizadas como semelhantes ou não semelhantes às do ser humano, com base na celularidade e na arquitetura histológica das estruturas. DESENHO CIENTÍFICO: Experimental. RESULTADOS: Constatou-se semelhança quanto ao tipo de epitélio, componente ósseo, espaços da fenda auditiva e arquitetura, além da semelhança, em nível histológico, tanto dos componentes celulares como das estruturas contíguas ao ouvido. As

  3. Osteodistrofias raras do osso temporal Rare osteodysplasia of the temporal bone

    Directory of Open Access Journals (Sweden)

    Marcos L. Antunes

    2005-04-01

    Full Text Available As osteodistrofias do osso temporal podem se manifestar de diversas maneiras, como envolvimento restrito ao osso temporal ou com envolvimento de outros ossos do crânio ou ainda fazerem parte de uma manifestação sistêmica. Consideramos, em nosso trabalho, duas entidades como osteodistofias raras, a osteopetrose e a doença de Camurati-Engelmann, esta última de incidência extremamente rara, com poucos relatos na literatura. Apresentamos dois casos de osteopetrose em sua forma benigna (doença de Albers-Schöenberg, um paciente de 11 anos e outro de 48 anos, ambos do sexo masculino, e um paciente de 28 anos do sexo feminino com a doença de Camurati-Engelmann (displasia diafisária hereditária progressiva, doenças hereditárias autossômicas que apresentam sintomas diversos. A paralisia facial periférica se manifestou em dois dos nossos pacientes. Discutimos alguns aspectos relacionados às manifestações clínicas destas doenças, achados radiológicos, assim como o diagnóstico diferencial e a conduta terapêutica diante de complicações das doenças.Temporal bone osteodysplasia can produce many different symptoms, such as involvement restricted to the temporal bone or impairment of other bones. We consider, in this study two entities that are rare osteodysplasia cases, which are osteopetrosis and Camurati-Engelmann disease, the latter being extremely rare. We present two cases of benign form of osteopetrosis (Albers-Schulenburg's disease, a patient of 11 years old and another one of 48 years old, both male, and a patient of 28 years old, female, with Camurati-Engelmann's disease. The facial palsy was a manifestation in two of the patients. We discuss some aspects about the clinical manifestations, radiological findings, as well as differential diagnostic and therapy in view of the complications of the diseases.

  4. Radiation dose optimization in pediatric temporal bone computed tomography: influence of tube tension on image contrast and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Nauer, Claude Bertrand [University Hospital Berne, Institute of Diagnostic and Interventional Neuroradiology, Berne (Switzerland); Zentrales Roentgeninstitut, Kantonsspital Graubuenden, Chur (Switzerland); Zubler, Christoph; Weisstanner, Christian [University Hospital Berne, Institute of Diagnostic and Interventional Neuroradiology, Berne (Switzerland); Stieger, Christof [University Berne, Group for Artificial Hearing Research, ARTORG Center, Berne (Switzerland); Senn, Pascal [University Hospital Berne, Department of ENT, Head and Neck Surgery, Berne (Switzerland); Arnold, Andreas [University Berne, Group for Artificial Hearing Research, ARTORG Center, Berne (Switzerland); University Hospital Berne, Department of ENT, Head and Neck Surgery, Berne (Switzerland)

    2012-03-15

    The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT). Seven lamb heads with infant-equivalent sizes were scanned repeatedly, using four tube tensions from 140 to 80 kV while the CT-Dose Index (CTDI) was held constant. Scanning was repeated with four CTDI values from 30 to 3 mGy. Image contrast was calculated for the middle ear as the Hounsfield unit (HU) difference between bone and air and for the inner ear as the HU difference between bone and fluid. The influence of tube tension on high-contrast detail delineation was evaluated using a phantom. The subjective image quality of eight middle and inner ear structures was assessed using a 4-point scale (scores 1-2 = insufficient; scores 3-4 = sufficient). Middle and inner ear contrast showed a near linear increase with tube tension reduction (r = -0.94/-0.88) and was highest at 80 kV. Tube tension had no influence on spatial resolution. Subjective image quality analysis showed significantly better scoring at lower tube tensions, with highest image quality at 80 kV. However, image quality improvement was most relevant for low-dose scans. Image contrast in the temporal bone is significantly higher at low tube tensions, leading to a better subjective image quality. Highest contrast and best quality were found at 80 kV. This image quality improvement might be utilized to further reduce the radiation dose in pediatric low-dose CT protocols. (orig.)

  5. The role of angiography in managing patients with temporal bone fractures: a retrospective study of 64 cases.

    Science.gov (United States)

    Ahmed, K Asif; Alison, David; Whatley, Wesley S; Chandra, Rakesh K

    2009-05-01

    We conducted a retrospective study of the utility of angiography in the evaluation of patients with temporal bone fractures. Our study population was made up of 64 patients-58 males and 6 females, aged 14 to 75 years (mean: 35.3)-with a temporal bone fracture who had presented to a level I trauma center over a 1-year period. Records were reviewed and data were obtained on the mechanism of injury; the type of fracture; associated injuries, particularly neurocranial injuries detected on computed tomography (CT) of the head; and any angiographic findings that might have been obtained. The primary outcomes measures were the type of treatment administered (conservative vs. surgical) and mortality. Patients were assigned to 1 of 4 groups according to CT results and angiographic findings, if any: normal CT and no angiogram (group 1; n = 12), abnormal CT and no angiogram (group 2; n = 28), abnormal CT and an abnormal angiogram (group 3; n = 9), and abnormal CT and a normal angiogram (group 4; n = 15). Conservative treatment was administered to all 12 patients in group 1 and to 9 patients (60%) in group 4; surgical treatment was provided to two-thirds of the patients in both group 2 and group 3. Mortality was low in group 1 (n = 0), group 3 (n = 1; 11%), and group 4 (n = 1; 7%), but high in group 2 (n = 10; 36%). In fact, the key finding of this study was that mortality in the group with an abnormal CT and no angiogram (group 2) was significantly higher than mortality in the group with an abnormal CT and an abnormal angiogram (group 3) (p = 0.02), even though the injuries in the 2 groups were similarly severe and their management was similarly aggressive. We conclude that current guidelines for angiography may need to be expanded to include all patients who have CT evidence of neurocranial injury in order to detect those vascular injuries that need aggressive management and thus lower overall mortality.

  6. The CT flare response of metastatic bone disease in prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, Christina; deSouza, Nandita M. (Cancer Research UK Clinical Magnetic Resonance Research Group, Inst. of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)), email: Christina.Messiou@icr.ac.uk; Cook, Gary (Dept. of Nuclear Medicine, Royal Marsden NHS Foundation Trust, Surrey (United Kingdom)); Reid, Alison H.M.; Attard, Gerhardt; Dearnaley, David; deBono, Johann S. (Inst. of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey (United Kingdom))

    2011-06-15

    Background New or worsening bone lesions in patients responding to treatment, known as the flare phenomenon is well described on 99mTc-MDP bone scintigraphy, but to our knowledge has not previously been described on CT. The appearance of new or worsening bone sclerosis on CT in patients with prostate cancer may therefore be erroneously classified as disease progression. Purpose To assess the incidence of osteoblastic healing flare response at 3-month CT assessment in patients with castrate-resistant prostate cancer and to identify associated features that enable differentiation from progressive metastatic bone disease at 3 months. Material and Methods CT scans of 67 patients with castrate-resistant prostate cancer undergoing treatment were reviewed by a radiologist blinded to clinical outcome. Changes in number, size, and density of metastatic bone lesions were documented and Response Evaluation Criteria in Solid Tumours (RECIST) in soft tissue lesions, alkaline phosphatase, prostate specific antigen, and 99mTc-MDP bone scans were used for correlation. Results Of the 39 patients who had 3- and 6-month follow-up, eight patients (21%) demonstrated an increase in number, size, or density of sclerotic lesions on the 3-month CT scan despite improvement in PSA and soft tissue lesions. Three out of eight patients (8%) maintained partial response/remained stable at follow-up and were defined as showing a flare response: in this group bone metastases evident on CT showed a qualitative and quantitative increase in density and no lesions faded at 3 months. In contrast, in all patients who progressed at 3 months by PSA/RECIST criteria (n = 8) bone lesions showed a mixed pattern with some lesions increasing and others decreasing in density. Conclusion The incidence of flare response of metastatic bone disease evident at 3-month post-treatment CT in patients with prostate cancer undergoing systemic treatment is 8%. In patients with falling PSA and stable/responding soft tissue

  7. Evaluation of bone substitute materials: comparison of flat-panel based volume CT to conventional multidetector CT.

    Science.gov (United States)

    Sauerbier, Sebastian; Duttenhoefer, Fabian; Sachlos, Elefterios; Haberstroh, Jörg; Scheifele, Christian; Wrbas, Karl-Thomas; Voss, Pit Jacob; Veigel, Egle; Smedek, Jörg; Ganter, Philip; Tuna, Taskin; Gutwald, Ralf; Palmowski, Moritz

    2013-10-01

    Over the last decade tissue engineering has emerged as a key factor in bone regeneration within the field of cranio-maxillofacial surgery. Despite this in vivo analysis of tissue-engineered-constructs to monitor bone rehabilitation are difficult to conduct. Novel high-resolving flat-panel based volume CTs (fp-VCT) are increasingly used for imaging bone structures. This study compares the potential value of novel fp-VCT with conventional multidetector CT (MDCT) based on a sheep sinus floor elevation model. Calcium-hydroxyapatite reinforced collagen scaffolds were populated with autologous osteoblasts and implanted into sheep maxillary sinus. After 8, 16 and 24 weeks MDCT and fp-VCT scans were performed to investigate the volume of the augmented area; densities of cancellous and compact bone were assessed as comparative values. fp-VCT imaging resulted in higher spatial resolution, which was advantageous when separating closely related anatomical structures (i.e. trabecular and compact bone, biomaterials). Fp-VCT facilitated imaging of alterations occurring in test specimens over time. fp-VCTs therefore displayed high volume coverage, dynamic imaging potential and superior performance when investigating superfine bone structures and bone remodelling of biomaterials. Thus, fp-VCTs may be a suitable instrument for intraoperative imaging and future in vivo tissue-engineering studies.

  8. Dynamic perfusion CT: Optimizing the temporal resolution for the calculation of perfusion CT parameters in stroke patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaemena, Andreas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)], E-mail: andreas.kaemena@charite.de; Streitparth, Florian; Grieser, Christian; Lehmkuhl, Lukas [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany); Jamil, Basil [Department of Radiotherapy, Charite-Medical University Berlin, Schumannstr. 20/21, D-10117 Berlin (Germany); Wojtal, Katarzyna; Ricke, Jens; Pech, Maciej [Department of Radiology, Charite-Medical University Berlin, Augustenburger Platz 1, D-13353 Berlin (Germany)

    2007-10-15

    Purpose: To assess the influence of different temporal sampling rates on the accuracy of the results from cerebral perfusion CTs in patients with an acute ischemic stroke. Material and methods: Thirty consecutive patients with acute stroke symptoms received a dynamic perfusion CT (LightSpeed 16, GE). Forty millilitres of iomeprol (Imeron 400) were administered at an injection rate of 4 ml/s. After a scan delay of 7 s, two adjacent 10 mm slices at 80 kV and 190 mA were acquired in a cine mode technique with a cine duration of 49 s. Parametric maps for the blood flow (BF), blood volume (BV) and mean transit time (MTT) were calculated for temporal sampling intervals of 0.5, 1, 2, 3 and 4 s using GE's Perfusion 3 software package. In addition to the quantitative ROI data analysis, a visual perfusion map analysis was performed. Results: The perfusion analysis proved to be technically feasible with all patients. The calculated perfusion values revealed significant differences with regard to the BF, BV and MTT, depending on the employed temporal resolution. The perfusion contrast between ischemic lesions and healthy brain tissue decreased continuously at the lower temporal resolutions. The visual analysis revealed that ischemic lesions were best depicted with sampling intervals of 0.5 and 1 s. Conclusion: We recommend a temporal scan resolution of two images per second for the best detection and depiction of ischemic areas.

  9. [A general review on the procedures in a human temporal bone laboratory].

    Science.gov (United States)

    Oktay, Mehmet Faruk; Cüreoğlu, Sebahattin; Schachern, Patricia A; Paparella, Micheal M

    2006-01-01

    Structures of the human ear are usually inaccessible during life for examination of pathologic changes of the underlying disease, which is only possible with postmortem studies of the human temporal bone. Human temporal bone laboratories serve as a unique source of material for research in this respect. They enable comparison between histologic findings of temporal bone sections and the ear pathologies documented prior to death, as well as comparison of diseased ears with any selected temporal bone specimens, both of which provide invaluable knowledge to be shared among researchers and other laboratories. This article aims to provide insight into the functions of temporal bone laboratories and to familiarize the reader with histopathologic studies conducted therein.

  10. Case of bilateral pneumolabyrinth presenting as sudden, bilateral deafness, without temporal bone fracture, after a fall.

    Science.gov (United States)

    Lee, E J; Yang, Y S; Yoon, Y J

    2012-07-01

    We report a case of bilateral pneumolabyrinth presenting as sudden, bilateral deafness, without temporal bone fracture, after a fall. A 49-year-old man presented with sudden, bilateral deafness and whirling vertigo, without any other neurological manifestations. Temporal bone computed tomography clearly demonstrated the presence of air in the vestibule and cochlea on both sides. However, there was no definite fracture line, ossicular chain anomaly or soft tissue density in the temporal bone or middle-ear cavity. The patient was treated conservatively. Unfortunately, there was no improvement in his hearing. Pneumolabyrinth is an uncommon condition in which air is present in the vestibule or cochlea. It is rarely found, even with fractures violating the otic capsule or with transverse fractures of the temporal bone. In addition, its bilateral occurrence is extremely rare. In this article, we describe a case of bilateral pneumolabyrinth presenting as sudden, bilateral deafness, without temporal bone fracture, an occurrence which has not previously been reported.

  11. An individual drug-therapy and genetic testing report of temporal bone verrucous carcinoma.

    Science.gov (United States)

    Tan, Haolei; Liu, Yong; Zhu, Gangcai; Pi, Leiming; Huang, Donghai; Zhang, Xin

    2014-01-01

    To investigate the pathology and pathogenesis of and treatment methods for temporal bone verrucous carcinoma. A single-patient report of verrucous carcinoma on the left external auditory canal is presented and analyzed along with all cases of temporal bone verrucous carcinoma that have been documented in the English literature. Most of the patients with verrucous carcinoma of the temporal bone have histories of surgery, trauma, or infection, and verrucous carcinomas are sensitive to antimicrotubule chemotherapeutic medicines. Adjuvant radiation therapy is not effective, but surgical treatment might be relatively more effective. Temporal bone verrucous carcinoma has a poor prognosis; therefore, the preferred treatment is surgical resection facilitated with antimicrotubule chemotherapeutic treatment. Adjuvant radiation therapy is not a preferred treatment for temporal bone verrucous carcinoma.

  12. Plain film and CT observations in prostaglandin-induced bone changes

    Energy Technology Data Exchange (ETDEWEB)

    Matzinger, M.A.; Briggs, V.A.; Dunlap, H.J.; Udjus, K.; Martin, D.J.; McDonald, P. (Children' s Hospital of Eastern Ontario, Ottawa, ON (Canada). Dept. of Radiology)

    1992-08-01

    Prostaglandin E[sub 1] intravenous infusion is used in infants with ductal-dependent cogenital heart disease to maintain ductal patency and prolong life until palliative or corrective surgery is feasible. Complications of prostaglandin administration include fever, diarrhoea, hypotension, apnoea, bradycardia, pseudowidening of the cranial sutures, underossification of the calvarial bones, periostitis, and skin edema. This paper presents dramatic plain radiographic features of prostaglandin-induced bone disease, inlcuding periosteal proliferation and the unusual bone-within-bone apperance, and provides the previously unpublished CT correlation. (orig.).

  13. Micro-CT characterization of human trabecular bone in osteogenesis imperfecta

    Science.gov (United States)

    Jameson, John; Albert, Carolyne; Smith, Peter; Molthen, Robert; Harris, Gerald

    2011-03-01

    Osteogenesis imperfecta (OI) is a genetic syndrome affecting collagen synthesis and assembly. Its symptoms vary widely but commonly include bone fragility, reduced stature, and bone deformity. Because of the small size and paucity of human specimens, there is a lack of biomechanical data for OI bone. Most literature has focused on histomorphometric analyses, which rely on assumptions to extrapolate 3-D properties. In this study, a micro-computed tomography (μCT) system was used to directly measure structural and mineral properties in pediatric OI bone collected during routine surgical procedures. Surface renderings suggested a poorly organized, plate-like orientation. Patients with a history of bone-augmenting drugs exhibited increased bone volume fraction (BV/TV), trabecular number (Tb.N), and connectivity density (Eu.Conn.D). The latter two parameters appeared to be related to OI severity. Structural results were consistently higher than those reported in a previous histomorphometric study, but these differences can be attributed to factors such as specimen collection site, drug therapy, and assumptions associated with histomorphometry. Mineral testing revealed strong correlations with several structural parameters, highlighting the importance of a dual approach in trabecular bone testing. This study reports some of the first quantitative μCT data of human OI bone, and it suggests compelling possibilities for the future of OI bone assessment.

  14. {sup 18}F-FDG PET/CT bone/bone marrow findings in Hodgkin's lymphoma may circumvent the use of bone marrow trephine biopsy at diagnosis staging

    Energy Technology Data Exchange (ETDEWEB)

    Moulin-Romsee, Gerard [Universite Paris 7, Service de Medicine Nucleaire, Hopital Saint-Louis, Assistance Publique-Hopitaux de Paris (France); Institut Curie, Nuclear Medicine, Paris (France); Hindie, Elif; Filmont, Jean-Emmanuel; Moretti, Jean-Luc [Universite Paris 7, Service de Medicine Nucleaire, Hopital Saint-Louis, Assistance Publique-Hopitaux de Paris (France); Cuenca, Xavier; Brice, Pauline; Sibon, David [Hopital Saint-Louis, Haemato-Oncology, Paris (France); Decaudin, Didier; Anitei, Marcela [Institut Curie, Haematology, Paris (France); Benamor, Myriam [Institut Curie, Nuclear Medicine, Paris (France); Briere, Josette [Hopital Saint-Louis, Pathology, Paris (France); Kerviler, Eric de [Hopital Saint-Louis, Radiology, Paris (France)

    2010-06-15

    Accurate staging of Hodgkin's lymphoma (HL) is necessary in selecting appropriate treatment. Bone marrow trephine biopsy (BMB) is the standard procedure for depicting bone marrow involvement. BMB is invasive and explores a limited part of the bone marrow. {sup 18}F-FDG PET/CT is now widely used for assessing response to therapy in HL and a baseline study is obtained to improve accuracy. The aim of this retrospective analysis was to assess whether routine BMB remains necessary with concomitant {sup 18}F-FDG PET/CT. Data from 83 patients (newly diagnosed HL) were reviewed. All patients had received contrast-enhanced CT, BMB and {sup 18}F-FDG PET/CT. Results of BMB were not available at the time of {sup 18}F-FDG PET/CT imaging. Seven patients had lymphomatous involvement on BMB. Four patients had bone involvement on conventional CT (two with negative BMB). All patients with bone marrow and/or bone lesions at conventional staging were also diagnosed on {sup 18}F-FDG PET/CT scan. PET/CT depicted FDG-avid bone/bone marrow foci in nine additional patients. Four of them had only one or two foci, while the other had multiple foci. However, the iliac crest, site of the BMB, was not involved on {sup 18}F-FDG PET/CT. Osteolytic/sclerotic lesions matching FDG-avid foci were visible on the CT part of PET/CT in three patients. MRI ordered in three other patients suggested bone marrow involvement. Interim and/or end-therapy {sup 18}F-FDG PET/CT documented response of FDG-avid bone/bone marrow foci to chemotherapy in every patient. {sup 18}F-FDG PET/CT highly improves sensitivity for diagnosis of bone/bone marrow lesions in HL compared to conventional staging. (orig.)

  15. CT appearances of unilateral cleft palate 20 years after bone graft surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kolbenstvedt, A.; Aaloekken, T.M. [Rikshospitalet, Oslo (Norway). Dept. of Radiology; Arctander, K. [Rikshospitalet, Oslo (Norway). Dept. of Plastic Surgery; Johannessen, S. [Inst. of Clinical Dentistry, Oslo (Norway)

    2002-11-01

    Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give satisfactory functional and cosmetic results, certain abnormalities persist. A knowledge of these is a prerequisite for a complete and final evaluation of the surgical and orthodontic regimen. Cleft palate nasal cavity abnormalities CT.

  16. Accuracy of cancellous bone volume fraction measured by micro-CT scanning

    DEFF Research Database (Denmark)

    Ding, Ming; Odgaard, A; Hvid, I

    1999-01-01

    Volume fraction, the single most important parameter in describing trabecular microstructure, can easily be calculated from three-dimensional reconstructions of micro-CT images. This study sought to quantify the accuracy of this measurement. One hundred and sixty human cancellous bone specimens...... which covered a large range of volume fraction (9.8-39.8%) were produced. The specimens were micro-CT scanned, and the volume fraction based on Archimedes' principle was determined as a reference. After scanning, all micro-CT data were segmented using individual thresholds determined by the scanner...

  17. SPECT/CT imaging in bone scintigraphy of a case of clavicular osteoma

    Directory of Open Access Journals (Sweden)

    Yuka Yamamoto

    2014-05-01

    diphosphonate (HMDP. Whole-body image showed a focus of intensely increased uptake in the clavicle. Single photon emission computed tomography/ computed tomography (SPECT/CT images were also acquired and clearly showed intense uptake at the tumor site. Integrated SPECT/CT imaging supplies both functional and anatomic information about bone: the SPECT imaging improves sensitivity compared with planar imaging, the CT imaging provides precise localization of the abnormal uptake, and information on the shape and structure of the abnormalities improves the specificity of the diagnosis.

  18. Amyloidoma of the skull: pain radiographs, CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Hidalgo, F. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Aguilera, C. [Inst. de Diagnostic per la Imatge (IDI), Centre Bellvitge, Hospital Duran i Reynals, Barcelona (Spain); Monford, J.L. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Rene, M. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Muntane, A. [Dept. of Neuroradiology, Ciutat Sanitaria i Univ. de Bellvitge, Barcelona (Spain); Pons, L.C. [Inst. de Diagnostic per la Imatge (IDI), Centre Bellvitge, Hospital Duran i Reynals, Barcelona (Spain)

    1996-01-01

    Amyloidomas involving bone are rare. The 67-year-old man reported here had a large amyloidoma of the left frontal, parietal, sphenoid (greater wing) and temporal bones causing neural compression. Plain radiographs CT and MRI are shown. (orig.)

  19. Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant Lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Sung Min; Nam, Hyun Yeol; Kim, In Ju; Kim, Yong Ki [Pusan National University Hospital, Pusan (Korea, Republic of); Kim, Ju Sung [College of Medical Life Science, Silla University, Pusan (Korea, Republic of)

    2008-06-15

    Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p<0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p=0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

  20. Template-based automatic extraction of the joint space of foot bones from CT scan

    Science.gov (United States)

    Park, Eunbi; Kim, Taeho; Park, Jinah

    2016-03-01

    Clean bone segmentation is critical in studying the joint anatomy for measuring the spacing between the bones. However, separation of the coupled bones in CT images is sometimes difficult due to ambiguous gray values coming from the noise and the heterogeneity of bone materials as well as narrowing of the joint space. For fine reconstruction of the individual local boundaries, manual operation is a common practice where the segmentation remains to be a bottleneck. In this paper, we present an automatic method for extracting the joint space by applying graph cut on Markov random field model to the region of interest (ROI) which is identified by a template of 3D bone structures. The template includes encoded articular surface which identifies the tight region of the high-intensity bone boundaries together with the fuzzy joint area of interest. The localized shape information from the template model within the ROI effectively separates the bones nearby. By narrowing the ROI down to the region including two types of tissue, the object extraction problem was reduced to binary segmentation and solved via graph cut. Based on the shape of a joint space marked by the template, the hard constraint was set by the initial seeds which were automatically generated from thresholding and morphological operations. The performance and the robustness of the proposed method are evaluated on 12 volumes of ankle CT data, where each volume includes a set of 4 tarsal bones (calcaneus, talus, navicular and cuboid).

  1. Histopathologic ear findings of syphilis: a temporal bone study.

    Science.gov (United States)

    Hızlı, Ömer; Hızlı, Pelin; Kaya, Serdar; Monsanto, Rafael da Costa; Paparella, Michael M; Cureoglu, Sebahattin

    2016-09-01

    To the best of our knowledge, histopathologic studies of syphilitic ears have generally focused on hydropic changes; so far, no such studies have investigated peripheral vestibular otopathology using differential interference contrast microscopy, in patients with syphilis. For this study, we examined 13 human temporal bone samples from 8 patients with a history of syphilis. Using conventional light microscopy, we performed qualitative histopathologic assessment. In addition, using differential interference contrast microscopy, we performed type I and type II vestibular hair cell counts on each vestibular sense organ with minimal autolysis; in which the neuroepithelium was oriented perpendicular to the plane of section. We then compared vestibular hair cell densities (cells per 0.01 mm² surface area) in the syphilis group vs. the control group. In the syphilis group, we observed precipitate in the endolymphatic or perilymphatic spaces in 1 (7.7 %) of the samples and endolymphatic hydrops in eight (61.5 %) of the samples. Hydrops involved the cochlea (four samples) and/or saccule (four samples). In addition, the syphilis group experienced a significant loss of type II vestibular hair cells in the maculae of the utricle and saccule, and in the cristae of the lateral and posterior semicircular canals, as compared with the control group (P < 0.05).

  2. Pneumatization of the zygomatic process of temporal bone on computed tomograms

    Directory of Open Access Journals (Sweden)

    Friedrich, Reinhard E.

    2016-06-01

    Full Text Available Purpose: Zygomatic air cells (ZAC are a variant of temporal bone pneumatization that needs no treatment. However, ZAC can have an impact on surgical procedures in the temporo-mandibular joint region. Recent reports suggest that computed tomography will disclose more ZAC than can be diagnosed on panoramic radiography. The aim of this study was to analyze ZAC prevalence on CT in a population that was not pre-selected by admission to a dental clinic. Furthermore, an extensive literature review was performed to assess the prevalence of ZAC and to address the impact of imaging technique on the definition of the item.Material and methods: Digitalized cranial CTs of 2007 patients were retrospectively analyzed. The Frankfort horizontal was used to define a ZAC on sagittal CTs. Results: In this study group, 806 were female (40.16% and 1,201 were male (59.84%. Mean age was 49.96 years in the whole group (female: 55.83 years, male: 46.01 years. A ZAC was diagnosed in 152 patients (female: 66, male: 86. Unilateral ZAC surpasses bilateral findings (115 vs. 37 patients. ZAC were diagnosed in children 5 years of age and older. Sectional imaging techniques show a better visualization of the region of interest. However, presently an increase of ZAC prevalence attributable to imaging technique cannot conclusively be derived from the current literature. The normal finding of a ZAC on radiograms is a sharply defined homogenous transparent lesion restricted to the zygomatic process of the temporal bone that has no volume effect on the shape of the process.Conclusion: ZAC is an anatomical variant of the temporal bone that has come into focus of maxillofacial radiology due to its noticeable aspect on panoramic radiograms. The harmless variant can be expected in about one in thirteen individuals undergoing facial radiology. Panoramic radiograms appear to be sufficient to present ZAC of relevant size. However, in preparation for surgical procedures affecting the

  3. HYPEROSTOSIS OF THE FRONTAL, TEMPORAL, AND SPHENOID BONES: CASE REPORT AND REVIEW OF LITERATURE

    Directory of Open Access Journals (Sweden)

    Austin Huy Nguyen

    2015-03-01

    Full Text Available Hyperostosis of the internal table of the frontal bone is not an uncommon phenomenon. However, such hyperostosis of the temporal and/or sphenoid bone is rarely discussed in the available literature, especially in the absence of meningioma. We report a case of hyperostosis of the frontal, temporal, and sphenoid bones found during routine cadaveric dissection of an 81 year-old female. Histology revealed thickening and increased density of the lamellar bone. The periosteum was unaffected. Possible etiology is discussed.

  4. Relationships between age and microarchitectural descriptors of iliac trabecular bone determined by microCT.

    Science.gov (United States)

    Deguette, C; Ramond-Roquin, A; Rougé-Maillart, C

    2017-06-01

    Estimation of age at death is a major issue in anthropology. The main anthropological histological methods propose studying the architecture of cortical bone. In bone histomorphometry, researches on metabolic bone diseases have provided normative tables for trabecular bone volume (BV/TV) according to age and gender of individuals on trans-iliac bone biopsies. We have used microCT, a non-destructive tool for measuring bone volume and trabecular descriptors to compare the French tables to a series of forensic anthropological population and if the two iliac bones could be used interchangeably. Coxal bone of a personal forensic collection whose age and gender were known (DNA identification) were used. Bone samples, centered on the same area than bone biopsy. MicroCT (pixel size: 36μm) was used to measure BV/TV and morphometric trabecular parameters of microarchitecture. An adjusted Z-score was calculated for BV/TV to compare with normative tables and a right/left comparison of trabecular parameters was provided. Twenty-seven iliac bones, which 20 forming 10 complete pelvises, aged between 24 and 73y.o. (average of 47.7 y.o.) were used. All adjusted Z-score were within normal values. There was a strong positive correlation between right and left sides for Tb.Th, Tb.N and Tb.Sp, but an insignificant correlation was obtained for BV/TV. Normative tables between age and BV/TV are valid and therefore usable in anthropology. They may represent an alternative to determine the age at death. Nevertheless, it requires a precise technique that could be a drawback in current practice. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  5. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.|info:eu-repo/dai/nl/111379628; Mohamed Hoesein, Firdaus A A|info:eu-repo/dai/nl/341235512; de Jong, Pim A.|info:eu-repo/dai/nl/287955672

    2015-01-01

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and 5

  6. Sacral pseudotumor complicating iliac bone harvest: radiographic, CT and MRI appearances

    Energy Technology Data Exchange (ETDEWEB)

    Kavanagh, E.; Roth, C.; O' Connell, M.; Eustace, S. [Dept. of Radiology, Mater Misericordiae Hospital, Dublin (Ireland)

    2003-12-01

    We present the imaging appearances of a lytic pseudotumor in the right sacral ala presenting with referred pain to the right thigh. Subsequent imaging revealed the presence of a cystic lesion arising at the site of previous bone graft harvest; CT-guided aspiration yielded synovial fluid presumed to arise from the contiguous sacroiliac joint. (orig.)

  7. Intravenous contrast injection significantly affects bone mineral density measured on CT

    NARCIS (Netherlands)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J. J.; Mohamed Hoesein, Firdaus A A; de Jong, Pim A.

    2015-01-01

    OBJECTIVE: The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. METHODS: One hundred and fifty-two patients (99 without and 5

  8. Rank-sparsity constrained, spectro-temporal reconstruction for retrospectively gated, dynamic CT

    Science.gov (United States)

    Clark, D. P.; Lee, C. L.; Kirsch, D. G.; Badea, C. T.

    2015-03-01

    Relative to prospective projection gating, retrospective projection gating for dynamic CT applications allows fast imaging times, minimizing the potential for physiological and anatomic variability. Preclinically, fast imaging is attractive due to the rapid clearance of low molecular weight contrast agents and the rapid heart rate of rodents. Clinically, retrospective gating is relevant for intraoperative C-arm CT. More generally, retrospective sampling provides an opportunity for significant reduction in x-ray dose within the framework of compressive sensing theory and sparsity-constrained iterative reconstruction. Even so, CT reconstruction from projections with random temporal sampling is a very poorly conditioned inverse problem, requiring high fidelity regularization to minimize variability in the reconstructed results. Here, we introduce a highly novel data acquisition and regularization strategy for spectro-temporal (5D) CT reconstruction from retrospectively gated projections. We show that by taking advantage of the rank-sparse structure and separability of the temporal and spectral reconstruction sub-problems, being able to solve each sub-problem independently effectively guarantees that we can solve both problems together. In this paper, we show 4D simulation results (2D + 2 energies + time) using the proposed technique and compare them with two competing techniques— spatio-temporal total variation minimization and prior image constrained compressed sensing. We also show in vivo, 5D (3D + 2 energies + time) myocardial injury data acquired in a mouse, reconstructing 20 data sets (10 phases, 2 energies) and performing material decomposition from data acquired over a single rotation (360°, dose: ~60 mGy).

  9. A Look from the Inside: MicroCT Analysis of Burned Bones

    Directory of Open Access Journals (Sweden)

    Francesco Boschin

    2015-12-01

    Full Text Available MicroCT imaging is increasingly used in paleoanthropological and zooarchaeological research to analyse the internal microstructure of bone, replacing comparatively invasive and destructive methods. Consequently the analytical potential of this relatively new 3D imaging technology can be enhanced by developing discipline specific protocols for archaeological analysis. Here we examine how the microstructure of mammal bone changes after burning and explore if X-ray computed microtomography (microCT can be used to obtain reliable information from burned specimens. We subjected domestic pig, roe deer, and red fox bones to burning at different temperatures and for different periods using an oven and an open fire. We observed significant changes in the three-dimensional microstructure of trabecular bone, suggesting that biomechanical studies or other analyses (for instance, determination of age-at-death can be compromised by burning. In addition, bone subjected to very high temperatures (600°C or more became cracked, posing challenges for quantifying characteristics of bone microstructure. Specimens burned at 600°C or greater temperatures, exhibit a characteristic criss-cross cracking pattern concentrated in the cortical region of the epiphyses. This feature, which can be readily observed on the surface of whole bone, could help the identification of heavily burned specimens that are small fragments, where color and surface texture are altered by diagenesis or weathering.

  10. Lacunarity analysis of spatial pattern in CT images of vertebral trabecular bone for assessing osteoporosis.

    Science.gov (United States)

    Dougherty, Geoffrey; Henebry, Geoffrey M

    2002-03-01

    The structural integrity of vertebral trabecular bone is determined by the continuity of its trabecular network and the size of the holes comprising its marrow space, both of which determine the apparent size of the marrow spaces in a transaxial CT image. A model-independent assessment of the trabeculation pattern was determined from the lacunarity of thresholded CT images. Using test images of lumbar vertebrae from human cadavers, acquired at different slice thicknesses, we determined that both median thresholding and local adaptive thresholding (using a 7 x 7 window) successfully segmented the grey-scale images. Lacunarity analysis indicated a multifractal nature to the images, and a range of marrow space sizes with significant structure around 14-18 mm(2). Preliminary studies of in vivo images from a clinical CT scanner indicate that lacunarity analysis can follow the pattern of bone loss in osteoporosis by monitoring the homogeneity of the marrow spaces, which is related to the connectivity of the trabecular bone network and the marrow space sizes. Although the patient sample was small, derived parameters such as the maximum deviation of the lacunarity from a neutral (fractal) model, and the maximum derivative of this deviation, seem to be sufficiently sensitive to distinguish a range of bone conditions. Our results suggest that these parameters, used with bone mineral density values, may have diagnostic value in characterizing osteoporosis and predicting fracture risk.

  11. Effects of CT image segmentation methods on the accuracy of long bone 3D reconstructions.

    Science.gov (United States)

    Rathnayaka, Kanchana; Sahama, Tony; Schuetz, Michael A; Schmutz, Beat

    2011-03-01

    An accurate and accessible image segmentation method is in high demand for generating 3D bone models from CT scan data, as such models are required in many areas of medical research. Even though numerous sophisticated segmentation methods have been published over the years, most of them are not readily available to the general research community. Therefore, this study aimed to quantify the accuracy of three popular image segmentation methods, two implementations of intensity thresholding and Canny edge detection, for generating 3D models of long bones. In order to reduce user dependent errors associated with visually selecting a threshold value, we present a new approach of selecting an appropriate threshold value based on the Canny filter. A mechanical contact scanner in conjunction with a microCT scanner was utilised to generate the reference models for validating the 3D bone models generated from CT data of five intact ovine hind limbs. When the overall accuracy of the bone model is considered, the three investigated segmentation methods generated comparable results with mean errors in the range of 0.18-0.24 mm. However, for the bone diaphysis, Canny edge detection and Canny filter based thresholding generated 3D models with a significantly higher accuracy compared to those generated through visually selected thresholds. This study demonstrates that 3D models with sub-voxel accuracy can be generated utilising relatively simple segmentation methods that are available to the general research community.

  12. SPECT/spiral-CT hybrid imaging in unclear foci of increased bone metabolism: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Roemer, W.; Kuwert, T. [Nuklearmedizinische Klinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Beckmann, M.W. [Frauenklinik, Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany); Forst, R. [Lehrstuhl fuer Orthopaedie mit Orthopaedischer Chirurgie, Friedrich-Alexander Univ. Erlangen/Nuernberg (Germany); Bautz, W. [Radiologisches Inst., Friedrich-Alexander-Univ. Erlangen/Nuernberg (Germany)

    2005-07-01

    In bone scintigraphy, the differentiation between degenerative processes and bone metastases is still difficult. Therefore, additional radiological studies are regularly needed after bone scintigraphy. The now introduced hybrid-cameras combining single-photon emission computed tomography (SPECT) and spiral-CT are unique in the sense that they offer the opportunity to correlate the functional information with morphology in one session. We herein present two patients in whom this technological setup allowed a definite diagnosis in scintigraphically unclear vertebral lesions. In a patient with breast cancer, hypermetabolic lesions were clearly correlated with osteolyses. In another patient with synovial carcinoma, spondylosis and spondylarthrosis caused focal tracer uptake in the lumbar spine. In addition to an improved diagnostic accuracy, SPECT/Spiral-CT will considerably abbreviate the diagnostic process. (orig.)

  13. Fibrous dysplasia mimicking bone metastasis on both bone scintigraphy and {sup 18}F FDG PET CT: Diagnostic dilemma in a patient with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    KC, Sud Hir Suman; Sharma, Punit; Singh, Har Man Deep; Bal, Chand Rasekhar; Kumar, Rake Sh [India Institute of Medical Sciences, New Delhi (India)

    2012-12-15

    Bone is the most common distant site to which breast cancer metastasizes. Commonly used imaging modalities for imaging bone metastasis are bone scintigraphy, plain radiography, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). Although bone scintigraphy gas high sensitivity for detecting bone metastasis, its specificity is low. This is because of the fact that bone scintigraphy images secondary changes in bone rather than just tumor cells {sup 18}F fluorodeoxyglucose ({sup 18}F FDG) PET CT, on the other hand, directly images the tumor cells' glucose metabolism. Unfortunately, similar to bone scintigraphy, benign bone conditions can also show increased {sup 18}F FDG uptake on PET CT, and PET positive asymptomatic fibrous dysplasia can be misinterpreted as a metastasis. Fibrous dysplasia of bone has wide skeletal distribution, with variability of {sup 18}F FDG uptake and CT appearance. It is therefore important to recognize the characteristics of this skeletal dysplasia, to allow differentiation from skeletal metastasis. Bone lesions with {sup 18}F FDG uptake need to be carefully interpreted when evaluating patients with known malignancy. In doubtful cases, fibrous dysplasia should be given as a differential diagnosis and histopathological diagnosis may be warranted, as highlighted in the present case.

  14. Technical note: early post-mortem changes of human bone in taphonomy with μCT.

    Science.gov (United States)

    Le Garff, Erwan; Mesli, Vadim; Delannoy, Yann; Colard, Thomas; Demondion, Xavier; Becart, Anne; Hedouin, Valéry

    2016-12-29

    Post-mortem interval (PMI) estimation is an important issue in forensic medicine, particularly for criminal purposes and legal limitation periods. The goal of the present study is to examine the evolution of the trabecular cranial vault bone after 4 weeks of conservation in a controlled environment with micro-tomography (μCT) analyses.Four bone samples were extracted from a fresh human cranial vault (a donation to science according to the French law) and conserved in an air-controlled environment. The samples were weighed and μCT scanned at a 10-μm resolution every week after death for a month. The μCT features were identical for every sample. Each set of data from the μCTs was reconstructed, registered, and analyzed in terms of the total volume, bone volume, bone surface, number of trabeculae, trabeculae thickness, and mean distance of the trabeculae. The samples were conserved in a glass box in 20 °C air with 60% humidity in a laboratory hood between each μCT acquisition. Descriptive statistics were determined. Each sample was observed and compared to itself over time.After 1 month of conservation, the mean bone volume (-1.9%), bone surface (-5.1%), and trabecular number (-12.35%) decreased, whereas the mean trabecular separation (+5.55%) and trabecular thickness (+12.7%) increased. Many variations (i.e., increases and decreases) were observed between the extraction of the sample and the end of the 4 weeks of conservation. The present observations may be explained by bone diagenesis. Previous observations have indicated that protein and lipid losses occur with bone weight and volume losses. These diagenesis effects may explain the trabecular modifications observed in the present work. We observed many bone variations with the μCT scans between the beginning and the end of the conservation that had no explanations. Additional studies, particularly studies involving statistics, need to be performed to confirm our observations and explain these results

  15. Pneumolabyrinth secondary to temporal bone fracture: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Bacciu A

    2014-09-01

    Full Text Available Andrea Bacciu,1 Vincenzo Vincenti,1 Sampath Chandra Prasad,1 Daniela Tonni,1 Elisa Ventura,2 Salvatore Bacciu,1 Enrico Pasanisi1 1Department of Clinical and Experimental Medicine, Unit of Audiology and Paediatric Otolaryngology, 2Department of Neuroradiology, University Hospital of Parma, Parma, Italy Abstract: Pneumolabyrinth following temporal bone fracture is an extremely rare condition. It results from air entering the inner ear when a communication between the air-filled middle ear spaces and inner ear is established. The imaging modality of choice for pneumolabyrinth is high-resolution computed tomography of the temporal bone. Treatment options include conservative management (bed rest, antibiotics, corticosteroids or surgery (exploratory tympanotomy. We present the case of a 31-year-old female who had pneumolabyrinth secondary to a temporal bone fracture. The patient was treated surgically and made a full clinical recovery. Keywords: pneumolabyrinth, temporal bone fractures, head trauma

  16. Osteoradionecrosis of sphenoid and temporal bones in a patient with maxillary sinus carcinoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Inokuchi, T.; Sano, K.; Kaminogo, M. (Nagasaki Univ. School of Dentistry (Japan))

    1990-09-01

    A case of radionecrosis of sphenoid and temporal bones is reported. The patient received a combination of surgery, radiotherapy, and chemotherapy for his left maxillary sinus carcinoma. After the combined therapy, necrosis accompanying inflammation developed in the maxillary and temporal regions. Excision of the necrotic tissues was done, and the left ascending ramus of the mandible was resected because of persistent tumor mass at the left infratemporal fossa. Although the excision wound of the maxilla healed by epithelialization, an area of nonvital bone remained exposed in the temporal region, where progressive osteonecrosis with infection led to breakdown of the skin. The necrotic bones of the zygomatic arch and the sphenotemporal sutural region became visible through the skin defect, and computerized tomography scan revealed bone necrosis involving the inferolateral area and the base of the skull. Excision of the necrotic bone and reconstruction with sternocleidomastoid myocutaneous flap were performed.

  17. Comparison of (18)F-FDG PET/CT and (99 m)Tc-MDP bone scintigraphy for detection of bone metastasis in osteosarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Byung Hyun; Lim, Ilhan; Kim, Byung Il; Choi, Chang Woon; Lim, Sang Moo [Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Department of Nuclear Medicine, Seoul (Korea, Republic of); Kong, Chang-Bae; Song, Won Seok; Cho, Wan Hyeong; Jeon, Dae-Geun; Lee, Soo-Yong [Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Department of Orthopedic Surgery, Seoul (Korea, Republic of); Koh, Jae-Soo [Korea Cancer Center Hospital, Korea Institute of Radiological and Medical Sciences (KIRAMS), Department of Pathology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2013-12-15

    We compared the diagnostic performance of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) and (99 m)Tc-methylene diphosphonate bone scintigraphy (BS) for the detection of bone metastasis in osteosarcoma. We retrospectively reviewed 206 patients with stage II-IV osteosarcoma treated with surgery and chemotherapy as well as at least one paired PET/CT and BS scan (defined as an examination). PET/CT and BS images were interpreted separately. When analyzing the diagnostic yield of a combination of PET/CT and BS (PET/CT+BS), an examination was considered positive if either PET/CT or BS scored positive. The final diagnosis was obtained from histological findings or clinical follow-up with imaging studies for at least 6 months. Diagnostic performances of PET/CT, BS, and their combinations were calculated. Out of 833 examinations in 206 patients, 55 with 101 lesions in 38 patients were confirmed as bone metastases. The sensitivity, specificity, and diagnostic accuracy were 95, 98, and 98 %, respectively, for PET/CT; 76, 97, and 96 %, respectively, for BS; and 100, 96, and 97 %, respectively, for PET/CT+BS in an examination-based analysis. Lesion-based analysis demonstrated that the sensitivity of PET/CT+BS (100 %) was significantly higher than that of PET/CT (92 %) or BS (74 %) alone. BS detected significantly less bone metastases in the growth plate region than outside the growth plate region (22 vs. 77 %). PET/CT is more sensitive and accurate than BS for diagnosing bone metastases in osteosarcoma. The combined use of PET/CT and BS improves sensitivity. (orig.)

  18. CT-based bone density assessment for iliosacral screw trajectories

    Directory of Open Access Journals (Sweden)

    Andreas Schicho

    2016-01-01

    Full Text Available Introduction: Sacroiliac screw placement is one standard treatment option for stabilization of posterior pelvic ring injuries encountering high intra- and inter-individual variations of bone stock quality as well as a vast variety and prevalence of sacral dysmorphism. An individual, easy-to-use preoperative bone stock quality estimation would be of high value for the surgeon. Materials and Methods: We analyzed 36 standard computed tomography datasets with the uninjured pelvic ring. Using a two-plane cross-referencing technique, we assessed the Hounsfield unit (HU mean values as well as standard deviation and minimum/maximum values within selected region of interests (ROIs at five key areas: os ilium left and right, massa lateralis of os sacrum left and right, and central vertebral body on levels S1 and S2. Results: Results showed no difference in mean HU at any ROI when comparing male and female data. For all ROIs set on S1 and S2, there was an age-related decline of HU with a calculated slope significantly different from zero. There was no statistical difference of slopes when comparing S1- and S2-level with respect to any distinct ROI. Comparison of levels S1 and S2 revealed differences at the vertebral body and at the right os ilium. The right and left massa lateralis of os sacrum had lower bone density than the center of the vertebral body, the right, or left os ilium on S1; right and left massa lateralis density did not differ significantly. On level S2, results were comparable with no difference of massa lateralis density. Conclusion: With our easy-to-use preoperative assessment of bone density of five key areas of sacroiliac screw anchoring we were able to find the lowest bone density in both the left and right massa lateralis on levels S1 and S2 with high inter- and intra-individual variations. Significantly lower bone density was found in the center of the vertebral bodies S2 in comparison to S1, which both are crucial for iliosacral

  19. Inflammatory Pseudotumor of the Temporal Bone: Three Cases and a Review of the Literature

    Directory of Open Access Journals (Sweden)

    Huiqin Tian

    2013-01-01

    Full Text Available Inflammatory pseudotumor (IP is a clinically aggressive but histologically benign condition of unknown cause. Its appearance in the temporal bone is uncommon. We present clinical, radiological, and histopathologic findings of three cases originating in the temporal bone. In the first case, a simultaneous IP of the temporal bone and parotid gland was found with histopathologic confirmation. In the second case, an enlarged cervical node, which was also believed to be related to IP, was observed accompanied with the temporal lesion. While the third case presented with chronic suppurative otitis media. Two of them were treated by surgery alone with complete resolve of the diseases. Another one underwent tympanomastoidectomy in combination with oral steroids, radiation, and chemotherapy, but the IP still recurred. A comprehensive review of the literature on clinical features of the temporal pseudotumor was conducted.

  20. Bone Micro-CT Assessments in an Orchidectomised Rat Model Supplemented with Eurycoma longifolia

    Directory of Open Access Journals (Sweden)

    Rosmaliza Ramli

    2012-01-01

    Full Text Available Recent studies suggested that Eurycoma longifolia, a herbal plant, may have the potential to treat osteoporosis in elderly male. This study aimed to determine the effects of Eurycoma longifolia supplementation on the trabecular bone microarchitecture of orchidectomised rats (androgen-deficient osteoporosis model. Forty-eight-aged (10–12 months old Sprague Dawley rats were divided into six groups of sham-operated (SHAM, orchidectomised control (ORX, orchidectomised + 7 mg/rat testosterone enanthate (TEN and orchidectomised + Eurycoma longifolia 30 mg/kg (EL30, orchidectomised + Eurycoma longifolia 60 mg/kg (EL60, orchidectomised + Eurycoma longifolia 90 mg/kg (EL90. Rats were euthanized following six weeks of treatment. The left femora were used to measure the trabecular bone microarchitecture using micro-CT. Orchidectomy significantly decreased connectivity density, trabecular bone volume, and trabecular number compared to the SHAM group. Testosterone replacement reversed all the orchidectomy-induced changes in the micro-CT parameters. EL at 30 and 60 mg/kg rat worsened the trabecular bone connectivity density and trabecular separation parameters of orchidectomised rats. EL at 90 mg/kg rat preserved the bone volume. High dose of EL (90 mg/kg may have potential in preserving the bone microarchitecture of orchidectomised rats, but lower doses may further worsen the osteoporotic changes.

  1. The diagnostic value of the sagittal multiplanar reconstruction CT images for nasal bone fractures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, B.H. [Department of Radiology, Korea University Ansan Hospital, 516 Gojan1-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-707 (Korea, Republic of); Seo, H.S., E-mail: seohs@korea.ac.k [Department of Radiology, Korea University Ansan Hospital, 516 Gojan1-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-707 (Korea, Republic of); Kim, A.-Y.; Lee, Y.S. [Department of Radiology, Dongguk University International Hospital, Gyunggi-do (Korea, Republic of); Lee, Y.H. [Department of Radiology, Korea University Ansan Hospital, 516 Gojan1-dong, Danwon-gu, Ansan-si, Gyunggi-do, 425-707 (Korea, Republic of); Suh, S.-I. [Department of Diagnostic Radiology, Korea University Guro Hospital, Seoul (Korea, Republic of); Lee, D.H. [Department of Radiology, Seoul Medical Center, Seoul (Korea, Republic of)

    2010-04-15

    Aim: To compare the diagnostic performance of sagittal multiplanar reconstruction (MPR) images and axial images for the detection of a nasal bone fracture. Materials and methods: This prospective study included 533 consecutive patients who underwent three-dimensional images with 64-section multidetector-row CT for the evaluation of a facial bone fracture between June 2007 and May 2008 (366 males; 167 females; mean age +- standard deviation 31.1 +- 21.2 years; age range 1-92 years). Two observers independently scored the possibility of a nasal bone fracture on axial and sagittal images. Receiver operating characteristic (ROC) curve analysis was performed. Results: The Az values of the sagittal images were higher than those of the axial images for both observers (p = 0.002 and 0.010, respectively) with higher accuracy (p < 0.001 and 0.016, respectively). The sensitivities of sagittal images were superior to those of axial images, especially for type 1 simple nasal bone fractures with no or minimal displacement (observer 1, 98.6 versus 72.8%; observer 2, 84.9 versus 71%). Conclusion: Sagittal MPR facial bone CT images provided superior diagnostic performance, and their addition to axial images is useful for the evaluation of nasal bone fractures.

  2. Evaluation of Response to Therapy in a Patient with Lung Cancer: Correlation of Sclerotic Bone Lesions with F 18 FDG PET/CT and Bone Scintigraphy

    Directory of Open Access Journals (Sweden)

    Filiz Özülker

    2011-04-01

    Full Text Available A 64-year-old male patient with small cell lung cancer underwent Fluorine-18 fluorodeoxyglucose (F 18 FDG positron emission tomography (PET/CT scan which revealed multiple F 18 FDG uptake in the spine, both humeri, ribs, pelvis and proximal long bones. There was no obvious lytic or sclerotic bone destruction accompanying these lesions on CT component of the study. After the patient received six courses of chemotherapy a repeat F 18 FDG-PET/CT was performed for evaluation of therapy response. The PET/CT showed the presence of multiple sclerotic lesions on CT without FDG uptake, corresponding to the bone lesions on the previous PET/CT scan. A concomitant Tc 99m Methylene diphosphonate (Tc 99m MDP bone scintigraphy (BS revealed no pathologically increased Tc 99m MDP uptake in the skeletal system. The FDG avid lesions in the skeletal system, which were not sclerotic initially, were transformed into FDG non-avid sclerotic lesions after chemotherapy. This was attributed to the direct effect of previous successful therapy for bone metastases, leading to the transformation of metabolically active disease, into blastic metabolically inactive metastases. In conclusion, a F 18 FDG negative bone lesion, which is sclerotic on CT, may represent post-treatment osteoblastic change rather than active tumor and BS might play a role in the discrimination of these two situations. (MIRT 2011; 20: 29-33

  3. 3D SPECT/CT fusion using image data projection of bone SPECT onto 3D volume-rendered CT images: feasibility and clinical impact in the diagnosis of bone metastasis.

    Science.gov (United States)

    Ogata, Yuji; Nakahara, Tadaki; Ode, Kenichi; Matsusaka, Yohji; Katagiri, Mari; Iwabuchi, Yu; Itoh, Kazunari; Ichimura, Akira; Jinzaki, Masahiro

    2017-05-01

    We developed a method of image data projection of bone SPECT into 3D volume-rendered CT images for 3D SPECT/CT fusion. The aims of our study were to evaluate its feasibility and clinical usefulness. Whole-body bone scintigraphy (WB) and SPECT/CT scans were performed in 318 cancer patients using a dedicated SPECT/CT systems. Volume data of bone SPECT and CT were fused to obtain 2D SPECT/CT images. To generate our 3D SPECT/CT images, colored voxel data of bone SPECT were projected onto the corresponding location of the volume-rendered CT data after a semi-automatic bone extraction. Then, the resultant 3D images were blended with conventional volume-rendered CT images, allowing to grasp the three-dimensional relationship between bone metabolism and anatomy. WB and SPECT (WB + SPECT), 2D SPECT/CT fusion, and 3D SPECT/CT fusion were evaluated by two independent reviewers in the diagnosis of bone metastasis. The inter-observer variability and diagnostic accuracy in these three image sets were investigated using a four-point diagnostic scale. Increased bone metabolism was found in 744 metastatic sites and 1002 benign changes. On a per-lesion basis, inter-observer agreements in the diagnosis of bone metastasis were 0.72 for WB + SPECT, 0.90 for 2D SPECT/CT, and 0.89 for 3D SPECT/CT. Receiver operating characteristic analyses for the diagnostic accuracy of bone metastasis showed that WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT had an area under the curve of 0.800, 0.983, and 0.983 for reader 1, 0.865, 0.992, and 0.993 for reader 2, respectively (WB + SPECT vs. 2D or 3D SPECT/CT, p < 0.001; 2D vs. 3D SPECT/CT, n.s.). The durations of interpretation of WB + SPECT, 2D SPECT/CT, and 3D SPECT/CT images were 241 ± 75, 225 ± 73, and 182 ± 71 s for reader 1 and 207 ± 72, 190 ± 73, and 179 ± 73 s for reader 2, respectively. As a result, it took shorter time to read 3D SPECT/CT images than 2D SPECT/CT (p < 0.0001) or WB

  4. {sup 68}Ga-DOTA-NOC PET/CT in comparison with CT for the detection of bone metastasis in patients with neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosini, Valentina; Nanni, Cristina; Castellucci, Paolo; Allegri, Vincenzo; Montini, Giancarlo; Franchi, Roberto [S. Orsola-Malpighi University Hospital, Department of Nuclear Medicine, Bologna (Italy); Zompatori, Maurizio [S. Orsola-Malpighi University Hospital, Department of Radiology, Bologna (Italy); Campana, Davide; Tomassetti, Paola [S. Orsola-Malpighi University Hospital, Department of Internal Medicine, Bologna (Italy); Rubello, Domenico [S. Maria della Misericordia Hospital, Department of Nuclear Medicine, Rovigo (Italy); Fanti, Stefano [S. Orsola-Malpighi University Hospital, Department of Nuclear Medicine, Bologna (Italy); Azienda Ospedaliero Universitaria di Bologna, Unita Operativa di Medicina Nucleare, Padiglione 30, Policlinico S.Orsola-Malpighi, Bologna (Italy)

    2010-04-15

    To retrospectively evaluate the sensitivity, specificity and accuracy of {sup 68}Ga-DOTA-NOC PET/CT and CT alone for the evaluation of bone metastasis in patients with neuroendocrine tumour (NET). From among patients with NET who underwent {sup 68}Ga-DOTA-NOC PET/CT between April 2006 and November 2008 in our centre, 223 were included in the study. Criteria for inclusion were pathological confirmation of NET and a follow-up period of at least 10 months. PET and CT images were retrospectively reviewed by two nuclear medicine specialists and two radiologists, respectively, without knowledge of the patient history or the findings of other imaging modalities. PET data were compared with the CT findings. Interobserver agreement was evaluated in terms of the kappa score. Clinical and imaging follow-up were used as the standard of reference to evaluate the PET findings. PET was performed for staging (49/223), unknown primary tumour detection (24/223), restaging (32/223), restaging before radioimmunotherapy (1/223), evaluation during therapy (12/223), equivocal findings on conventional imaging (4/223 at the bone level; 61/223 at sites other than bone), and follow-up (40/223). A very high interobserver agreement was observed. CT detected at least one bone lesion in only 35 of 44 patients with a positive PET scan. In particular, PET showed more lesions in 20/35 patients, a lower number of lesions in 8/35, and the same number in 7/35. The characteristics of the lesions (sclerotic, lytic, mixed) on the basis of the CT report did not influence PET reading. PET revealed the presence of at least one bone metastasis in nine patients with a negative CT scan. Considering patients with a negative PET scan (179), CT showed equivocal findings at the bone level in three (single small sclerotic abnormality in two at the spine level, and bilateral small sclerotic abnormalities in the humeri, femurs and scapula). Clinical follow-up confirmed the PET findings in all patients; thus there

  5. Three-minute SPECT/CT is sufficient for the assessment of bone metastasis as add-on to planar bone scintigraphy

    DEFF Research Database (Denmark)

    Zacho, Helle D; Manresa, José A Biurrun; Aleksyniene, Ramune

    2017-01-01

    BACKGROUND: The aim of this study is to assess whether ultra-fast acquisition SPECT/CT (UF-SPECT/CT) can replace standard SPECT/CT (std-SPECT/CT) as "add-on" to whole-body bone scintigraphy (WB-BS) for the investigation of bone metastases. Consecutive cancer patients referred for WB-BS who...... diagnosis was reached by two observers for each set of images (WB-BS + standard SPECT/CT or WB-BS + UF-SPECT/CT) using a three-category evaluation scale: M0: no bone metastases; M1: bone metastases; and Me: equivocal findings. RESULTS: Among the 104 included patients, most presented with prostate cancer (n...... in observer agreement between cancer types was detected. SPECT/CT provided a definitive classification in 90 of 104 cases in which WB-BS was not entirely diagnostic. CONCLUSIONS: To investigate potential bone metastases, UF-SPECT/CT can be conducted as add-on to WB-BS to notably reduce the SPECT acquisition...

  6. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Mats (Center for Medical Imaging and Physiology, Skaane University Hospital, Lund University, Lund (Sweden)), Email: mats@geijer.info; Dunker, Dennis; Collin, David; Goethlin, Jan H. (Department of Radiology, Sahlgrenska University Hospital, Moelndal (Sweden))

    2012-03-15

    Background. A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. Purpose. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. Material and Methods. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. Results. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Conclusion. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign

  7. Bone bruise, lipohemarthrosis, and joint effusion in CT of non-displaced hip fracture.

    Science.gov (United States)

    Geijer, Mats; Dunker, Dennis; Collin, David; Göthlin, Jan H

    2012-03-01

    A suspected occult hip fracture after normal radiography is not uncommon in an elderly person after a fall. Despite a lack of robust validation in the literature, computed tomography (CT) is often used as secondary imaging. To assess the frequency and clinical utility of non-cortical skeletal and soft tissue lesions as ancillary fracture signs in CT diagnosis of occult hip fractures. All fracture signs (cortical and trabecular fractures, bone bruise, joint effusion, and lipohemarthrosis) were recorded in 231 hip low-energy trauma cases with CT performed after normal or equivocal radiography in two trauma centers. There were no fracture signs in 110 patients. Twelve of these had a joint effusion. In 121 patients with 46 cervical hip fractures and 75 trochanteric fractures one or more fracture signs were present. Cortical fractures were found in 115 patients. Bone bruise was found in 119 patients, joint effusion in 35, and lipohemarthrosis in 20 patients. Ancillary signs such as bone bruise and lipohemarthrosis can strengthen and sometimes indicate the diagnosis in CT of occult hip fractures. Joint effusion is a non-specific sign.

  8. Assessment of Bone Metastases in Patients with Prostate Cancer—A Comparison between 99mTc-Bone-Scintigraphy and [68Ga]Ga-PSMA PET/CT

    Directory of Open Access Journals (Sweden)

    Lena Thomas

    2017-07-01

    Full Text Available Purpose: Bone scintigraphy is the standard of reference in bone metastases in prostate cancer patients. However, new radiotracers employed in prostate-specific membrane antigen (PSMA-ligands has led to the growing importance of PET/CT as diagnostic tool. The aim of our study was to investigate the difference between bone scan and PSMA-PET/CT for the detection of bone metastases in prostate cancer. Methods: Thirty patients with bone metastases originating from prostate cancer were examined by 99mTc-MDP bone scan and 68Ga-PSMA-PET/CT within an average of 21 days. Bone scans were analyzed visually according to the number of lesions and using the software package ExiniBONE by Exini Diagnostics. PET/CT data was analyzed visually. Numbers of detected lesions were compared for the different methods for the whole patient and for different regions. In addition, results were compared to serum prostate-specific antigen (PSA, alkaline phosphatase (ALP, bone alkaline phosphatase (bALP, pro gastrin releasing peptide (pGRP and eastern cooperative oncology group (ECOG performance status. Results: In the bone scans, visual and semiautomatic lesion detection showed similar results with an average of 19.4 and 17.8 detected bone lesion per patient. However, in PSMA-PET/CT, on average double the numbers of lesions (40.0 were detected. The largest differences were found in the thorax and pelvis, which can be explained by the advantages of tomographic imaging. Bland-Altman analysis showed greater differences in patients with large numbers of bone metastases. Conclusion: No significant difference was found when using semiautomatic analysis compared to visual reading for bone scans. Fewer bone metastases were detected in bone scans than in PSMA-PET/CT. However, in none of our patients would the difference have led to clinical consequences. Therefore, it seems that for patients undergoing PSMA-PET/CT, there is no need to perform additional bone scans if the appropriate

  9. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Plass, Andre [University Hospital Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Gaemperli, Oliver [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Center for Integrative Human Physiology, Zurich (Switzerland)

    2007-11-15

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  10. Effect of low-dose CT and iterative reconstruction on trabecular bone microstructure assessment

    Science.gov (United States)

    Kopp, Felix K.; Baum, Thomas; Nasirudin, Radin A.; Mei, Kai; Garcia, Eduardo G.; Burgkart, Rainer; Rummeny, Ernst J.; Bauer, Jan S.; Noël, Peter B.

    2016-03-01

    The trabecular bone microstructure is an important factor in the development of osteoporosis. It is well known that its deterioration is one effect when osteoporosis occurs. Previous research showed that the analysis of trabecular bone microstructure enables more precise diagnoses of osteoporosis compared to a sole measurement of the mineral density. Microstructure parameters are assessed on volumetric images of the bone acquired either with high-resolution magnetic resonance imaging, high-resolution peripheral quantitative computed tomography or high-resolution computed tomography (CT), with only CT being applicable to the spine, which is one of clinically most relevant fracture sites. However, due to the high radiation exposure for imaging the whole spine these measurements are not applicable in current clinical routine. In this work, twelve vertebrae from three different donors were scanned with standard and low radiation dose. Trabecular bone microstructure parameters were assessed for CT images reconstructed with statistical iterative reconstruction (SIR) and analytical filtered backprojection (FBP). The resulting structure parameters were correlated to the biomechanically determined fracture load of each vertebra. Microstructure parameters assessed for low-dose data reconstructed with SIR significantly correlated with fracture loads as well as parameters assessed for standard-dose data reconstructed with FBP. Ideal results were achieved with low to zero regularization strength yielding microstructure parameters not significantly different from those assessed for standard-dose FPB data. Moreover, in comparison to other approaches, superior noise-resolution trade-offs can be found with the proposed methods.

  11. Alternative oblique head CT scanning technique reduces bone artifact and improves interpretability of brainstem anatomy

    Directory of Open Access Journals (Sweden)

    Sam Douglas Kampondeni

    2010-06-01

    Full Text Available Brainstem pathology due to infections, infarcts and tumors are common in developing countries, but neuroimaging technology in these resource-poor settings is often limited to single slice, and occasionally spiral, CT. Unlike multislice CT and MRI, single slice and spiral CT are compromised by bone artifacts in the posterior fossa due to the dense petrous bones, often making imaging of the brainstem non-diagnostic. With appropriate head positioning, the petrous ridges can be avoided with 40˚ sagittal oblique scans parallel to either petrous ridge. We describe an alternative sagittal oblique scanning technique that significantly reduces brainstem CT artifacts thereby improving clarity of anatomy. With Inst­itutional Ethical approval, 13 adult patients were enrolled (5 males; 39%. All patients had routine axial brain CT and sagittal oblique scans with no lesions found. Images were read by 2 readers who gave a score for amount of artefact and clarity of structures in the posterior fossa. The mean artifact score was higher for routine axial images compared to sagittal oblique (2.92 vs. 1.23; P<0.0001. The mean anatomical certainty scores for the brainstem were significantly better in the sagittal oblique views compared to routine axial (1.23 vs. 2.77; P<0.0001. No difference was found between the two techniques with respect to the fourth ventricle or the cerebellum (axial vs. sag oblique: 1.15 vs. 1.27; P=0.37. When using single slice CT, the sagittal oblique scanning technique is valuable in improving clarity of anatomy in the brainstem if axial images are non-diagnostic due to bone artifacts.

  12. Comparison of calibrated and uncalibrated bone mineral density by CT to DEXA in menopausal women.

    Science.gov (United States)

    Miyabara, Y; Holmes, D; Camp, J; Miller, V M; Kearns, A E

    2012-08-01

    Coronary artery disease and osteoporosis increase in women after menopause. Computed tomography (CT) scans of the heart used to evaluate coronary arterial calcification include images of the thoracic vertebrae. The utility of using these images to assess bone health in women remains to be defined. Analyses of thoracic spine volumetric bone mineral density (vBMD) from CT scans of the heart were performed to determine how specific calibration affects the ability to assess vBMD in recently menopausal women and to evaluate how vBMD relates to areal bone mineral density (aBMD) using dual-energy X-ray absorptiometry (DEXA). Women (n = 111) enrolled in the Kronos Early Estrogen Prevention Study (KEEPS) at Mayo Clinic underwent a CT scan of the heart that included calibration phantoms and a DEXA of the lumbar spine. The Spine Cancer Assessment program was used to determine vBMD of thoracic vertebrae with and without the calibration correction. Trabecular bone vBMD at T8 averaged 163.57±28.58 and 157.94±27.55 mg/cc (mean±standard deviation, SD) for calibrated and uncalibrated values, respectively. The relationship between calibrated and uncalibrated measures approached unity (R = 0.98). Lumbar spine (L2-4) aBMD was 1.19±0.16 g/cm(2) (mean±SD). Both calibrated and uncalibrated thoracic vBMD correlated positively and significantly with lumbar aBMD, but the relationship was less than unity (R = 0.63). Uncalibrated measures of thoracic spine vBMD obtained from CT scans of the heart may provide clinically relevant information about bone health and osteoporosis/osteopenia risk in recently menopausal women.

  13. Anatomia do osso temporal de ovelhas sob aspectos didáticos Lambs' temporal bone anatomy under didactic aspects

    Directory of Open Access Journals (Sweden)

    André Gurr

    2011-02-01

    Full Text Available É difícil encontrar ossos temporais humanos para o ensino de cirurgia otológica. Ossos temporais de ovelhas podem representar uma possível alternativa. MATERIAIS E MÉTODOS: Os ossos temporais de ovelhas foram dissecados em um programa convencional de dissecação de osso temporal no laboratório. Incluímos mastoidectomia, abordagens endaurais, mas também analisamos a aparência externa, o meato acústico externo e o hipotímpano. Algumas etapas são diferentes das preparações de ossos humanos. Os resultados morfométricos foram comparados à anatomia conhecida de humanos para verificar se o osso temporal de ovelhas seria utilizável para o ensino de cirurgia otológica. RESULTADOS: O osso temporal de ovelhas parece menor do que o humano. Encontramos uma área bolhosa se estendendo ao hipotímpano abaixo do meato acústico externo. A membrana timpânica é muito semelhante à humana. O meato acústico externo é menor e mais curto. A cadeia ossicular exibe analogias para com a humana. DISCUSSÃO: Esse estudo mostra que especificamente o ouvido médio, a membrana timpânica e o conduto auditivo externo são morfologicamente semelhantes às suas contrapartidas encontradas nos ossos temporais humanos. A ovelha parece ser um modelo viável para o ensino da anatomia do ouvido. A menor escala de algumas estruturas, especialmente dos componentes externos do osso temporal representa uma desvantagem. CONCLUSÕES: A ovelha parece representar uma alternativa viável no ensino de cirurgia otológica.Human temporal bones in teaching ear surgery are rare. The lamb's temporal bone might be a possible alternative. MATERIAL AND METHODS: Temporal bones of the lamb were dissected with a typical temporal bone lab drilling program. We included a mastoidectomy, endaural approaches, but also analyzed the outer appearance, the external ear canal and the hypotympanon. Some steps differed from preparation done in humans. The morphometric results were compared to

  14. Dual-time FDG-PET/CT in patients with potential breast cancer recurrence: Head-to-head comparison with CT and bone scintigraphy

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; Gerke, Oke

    Dual-time FDG-PET/CT in patients with potential breast cancer recurrence: Head-to-head comparison with CT and bone scintigraphy  Kirsten Falch, Christina Baun, Oke Gerke, , Ziba A. Farahani, Poul F. Høilund-Carlsen, Lisbet B. Larsen*, Marianne Ewertz**, Katrine Søe*** and Malene G. Hildebrandt...... Departments of Nuclear Medicine, *Radiology, **Oncolocy, and ***Surgery, Odense University Hospital, Odense, Denmark Purpose: Breast cancer (BC) is the most common type of cancer among women in Denmark and about 1/3 of the affected women experience recurrence. The prognosis is good if loco regional recurrence...... FDG PET/CT, routine bone scintigraphy and CT of the chest and upper abdomen within 2 weeks. Patients with other malignancies, pregnant or lactating women, patients younger than 18 years and patients with confirmed metastatic disease were not eligible FDG PET/CT. All patients fasted for a minimum...

  15. Spinal uptake mimicking metastasis in SPECT/CT bone scan in a patient with superior vena cava obstruction.

    Science.gov (United States)

    Rager, Olivier; Nkoulou, René; Garibotto, Valentina; Boudabbous, Sana; Arditi, Daniel

    2013-11-01

    A 46-year-old female patient with a mediastinal neuroendocrine carcinoma complicated by superior vena cava syndrome was referred for a bone metastatic workup. Bone scan with SPECT/CT showed several vertebral fixations without alterations on the unenhanced CT, but a CT scan with injection of contrast media showed vertebral densities matched to the lesions described on the SPECT/CT. This pattern confirmed presence of collateral paths through vertebral veins due to superior vena cava syndrome. Lack of metastases was confirmed by MRI.

  16. Benign incidental findings of osteopoikilosis on Tc-99m MDP bone SPECT/CT: A case report and literature review.

    Science.gov (United States)

    Tsai, Szu-Ying; Wang, Shan-Ying; Shiau, Yu-Chien; Wu, Yen-Wen

    2016-06-01

    Osteopoikilosis is a benign but rare condition characterized by bone islands throughout the osseous tissue, which could be easily confused with bone metastasis. We present a case of a 37-year-old man presented to orthopedic outpatient clinic with right hip pain for 2 weeks. There were multiple, small punctate lesions scattered throughout the skeleton on radiograph. Subsequent Tc-99m methylene diphosphonate (MDP) bone scan with pelvic single-photon emission computed tomography (SPECT)/computed tomography (CT) showed multiple enostoses without abnormal focal MDP uptake. Therefore, clinical diagnosis was compatible with osteopoikilosis while bone metastasis was unlikely. The symptoms then improved by conservative treatments. Osteopoikilosis is usually an incidental finding on radiograph or CT, and a normal MDP confirmed the diagnosis by excluding bone metastasis. It is important for clinicians to recognize the specific image features to prevent further unnecessary interventions. In addition, bone SPECT/CT could also make the diagnosis in one step.

  17. Quantification of the accuracy of MRI generated 3D models of long bones compared to CT generated 3D models.

    Science.gov (United States)

    Rathnayaka, Kanchana; Momot, Konstantin I; Noser, Hansrudi; Volp, Andrew; Schuetz, Michael A; Sahama, Tony; Schmutz, Beat

    2012-04-01

    Orthopaedic fracture fixation implants are increasingly being designed using accurate 3D models of long bones based on computer tomography (CT). Unlike CT, magnetic resonance imaging (MRI) does not involve ionising radiation and is therefore a desirable alternative to CT. This study aims to quantify the accuracy of MRI-based 3D models compared to CT-based 3D models of long bones. The femora of five intact cadaver ovine limbs were scanned using a 1.5 T MRI and a CT scanner. Image segmentation of CT and MRI data was performed using a multi-threshold segmentation method. Reference models were generated by digitising the bone surfaces free of soft tissue with a mechanical contact scanner. The MRI- and CT-derived models were validated against the reference models. The results demonstrated that the CT-based models contained an average error of 0.15 mm while the MRI-based models contained an average error of 0.23 mm. Statistical validation shows that there are no significant differences between 3D models based on CT and MRI data. These results indicate that the geometric accuracy of MRI based 3D models was comparable to that of CT-based models and therefore MRI is a potential alternative to CT for generation of 3D models with high geometric accuracy.

  18. Aggressive osteoblastoma in mastoid process of temporal bone with facial palsy

    Directory of Open Access Journals (Sweden)

    Manoj Jain

    2013-01-01

    Full Text Available Osteoblastoma is an uncommon primary bone tumor with a predilection for posterior elements of spine. Its occurrence in temporal bone and middle ear is extremely rare. Clinical symptoms are non-specific and cranial nerve involvement is uncommon. The cytomorphological features of osteoblastoma are not very well defined and the experience is limited to only few reports. We report an interesting and rare case of aggressive osteoblastoma, with progressive hearing loss and facial palsy, involving the mastoid process of temporal bone and middle ear along with the description of cyto-morphological features.

  19. Giant cell tumor of the temporal bone – a case report

    Directory of Open Access Journals (Sweden)

    Rao Saraswathi G

    2005-09-01

    Full Text Available Abstract Background Giant cell tumor is a benign but locally aggressive bone neoplasm which uncommonly involves the skull. The petrous portion of the temporal bone forms a rare location for this tumor. Case presentation The authors report a case of a large giant cell tumor involving the petrous and squamous portions of the temporal bone in a 26 year old male patient. He presented with right side severe hearing loss and facial paresis. Radical excision of the tumor was achieved but facial palsy could not be avoided. Conclusion Radical excision of skull base giant cell tumor may be hazardous but if achieved is the optimal treatment and may be curative.

  20. The additional value of CT images interpretation in the differential diagnosis of benign vs. malignant primary bone lesions with 18F-FDG-PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, K.; Stumpe, K.D.M.; Hany, T.F.; Mende, K.; Veit-Haibach, P.; Schulthess, G.K. von [University Hospital Zurich, Division of Nuclear Medicine, Department of Medical Radiology, Zurich (Switzerland); Exner, U.E. [University Hospital Balgrist, Department of Orthopedic Surgery, Zurich (Switzerland); Bode, B. [University Hospital Zurich, Institute of Surgical Pathology, Zurich (Switzerland); Hodler, Juerg [University Hospital Balgrist, Department of Radiology, Zurich (Switzerland)

    2008-11-15

    To evaluate the value of a dedicated interpretation of the CT images in the differential diagnosis of benign vs. malignant primary bone lesions with 18fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT). In 50 consecutive patients (21 women, 29 men, mean age 36.9, age range 11-72) with suspected primary bone neoplasm conventional radiographs and 18F-FDG-PET/CT were performed. Differentiation of benign and malignant lesions was separately performed on conventional radiographs, PET alone (PET), and PET/CT with specific evaluation of the CT part. Histology served as the standard of reference in 46 cases, clinical, and imaging follow-up in four cases. According to the standard of reference, conventional 17 lesions were benign and 33 malignant. Sensitivity, specificity, and accuracy in assessment of malignancy was 85%, 65% and 78% for conventional radiographs, 85%, 35% and 68% for PET alone and 91%, 77% and 86% for combined PET/CT. Median SUV{sub max} was 3.5 for benign lesions (range 1.6-8.0) and 5.7 (range 0.8-41.7) for malignant lesions. In eight patients with bone lesions with high FDG-uptake (SUV{sub max} {>=} 2.5) dedicated CT interpretation led to the correct diagnosis of a benign lesion (three fibrous dysplasias, two osteomyelitis, one aneurysmatic bone cyst, one fibrous cortical defect, 1 phosphaturic mesenchymal tumor). In four patients with lesions with low FDG-uptake (SUV{sub max} < 2.5) dedicated CT interpretation led to the correct diagnosis of a malignant lesion (three chondrosarcomas and one leiomyosarcoma). Combined PET/CT was significantly more accurate in the differentiation of benign and malignant lesions than PET alone (p =.039). There was no significant difference between PET/CT and conventional radiographs (p =.625). Dedicated interpretation of the CT part significantly improved the performance of FDG-PET/CT in differentiation of benign and malignant primary bone lesions compared to PET alone. PET/CT more commonly

  1. {sup 18}F-Fluoride PET/CT is highly effective for excluding bone metastases even in patients with equivocal bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Bortot, Daniel C.; Amorim, Barbara J.; Oki, Glaucia C.; Santos, Allan O.; Lima, Mariana C.L.; Etchebehere, Elba C.S.C.; Ramos, Celso Dario [State University of Campinas (UNICAMP), Division of Nuclear Medicine, Department of Radiology, Avenue Zeferino Vaz, S/N., PO Box 6149, Campinas (Brazil); Gapski, Sergio B. [Medicina Nuclear Diagnostico e Terapia, Nuclear Medicine Clinic, Campinas (Brazil); Barboza, Marycel F.; Mengatti, Jair [Nuclear and Energy Research Institute (IPEN)-CNEN, Radiopharmacy Directory, Sao Paulo (Brazil)

    2012-11-15

    Bone scintigraphy (BS) has been used extensively for many years for the diagnosis of bone metastases despite its low specificity and significant rate of equivocal lesions. {sup 18}F-Fluoride PET/CT has been proven to have a high sensitivity and specificity in the detection of malignant bone lesions, but its effectiveness in patients with inconclusive lesions on BS is not well documented. This study evaluated the ability of {sup 18}F-fluoride PET/CT to exclude bone metastases in patients with various malignant primary tumours and nonspecific findings on BS. We prospectively studied 42 patients (34-88 years of age, 26 women) with different types of tumour. All patients had BS performed for staging or restaging purposes but with inconclusive findings. All patients underwent {sup 18}F-fluoride PET/CT. All abnormalities identified on BS images were visually compared with their appearance on the PET/CT images. All the 96 inconclusive lesions found on BS images of the 42 patients were identified on PET/CT images. {sup 18}F-Fluoride PET/CT correctly excluded bone metastases in 23 patients (68 lesions). Of 19 patients (28 lesions) classified by PET/CT as having metastases, 3 (5 lesions) were finally classified as free of bone metastases on follow-up. The sensitivity, specificity, and positive and negative predictive values of {sup 18}F-fluoride PET/CT were, respectively, 100 %, 88 %, 84 % and 100 % for the identification of patients with metastases (patient analysis) and 100 %, 82 % and 100 % for the identification of metastatic lesions (lesion analysis). The factors that make BS inconclusive do not affect {sup 18}F-fluoride PET/CT which shows a high sensitivity and negative predictive value for excluding bone metastases even in patients with inconclusive conventional BS. (orig.)

  2. Biomechanical Role of Bone Anisotropy Estimated on Clinical CT Scans by Image Registration.

    Science.gov (United States)

    Taghizadeh, Elham; Reyes, Mauricio; Zysset, Philippe; Latypova, Adeliya; Terrier, Alexandre; Büchler, Philippe

    2016-08-01

    Image-based modeling is a popular approach to perform patient-specific biomechanical simulations. Accurate modeling is critical for orthopedic application to evaluate implant design and surgical planning. It has been shown that bone strength can be estimated from the bone mineral density (BMD) and trabecular bone architecture. However, these findings cannot be directly and fully transferred to patient-specific modeling since only BMD can be derived from clinical CT. Therefore, the objective of this study was to propose a method to predict the trabecular bone structure using a µCT atlas and an image registration technique. The approach has been evaluated on femurs and patellae under physiological loading. The displacement and ultimate force for femurs loaded in stance position were predicted with an error of 2.5% and 3.7%, respectively, while predictions obtained with an isotropic material resulted in errors of 7.3% and 6.9%. Similar results were obtained for the patella, where the strain predicted using the registration approach resulted in an improved mean squared error compared to the isotropic model. We conclude that the registration of anisotropic information from of a single template bone enables more accurate patient-specific simulations from clinical image datasets than isotropic model.

  3. Quantitative assessment of bone defect healing by multidetector CT in a pig model

    Energy Technology Data Exchange (ETDEWEB)

    Riegger, Carolin; Kroepil, Patric; Lanzman, Rotem S.; Miese, Falk R.; Antoch, Gerald; Scherer, Axel [University Duesseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Duesseldorf (Germany); Jungbluth, Pascal; Hakimi, Mohssen; Wild, Michael [University Duesseldorf, Medical Faculty, Department of Traumatology and Hand Surgery, Duesseldorf (Germany); Hakimi, Ahmad R. [Universtity Duesseldorf, Medical Faculty, Department of Oral Surgery, Duesseldorf (Germany)

    2012-05-15

    To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 {+-} 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry. (orig.)

  4. From 3D to 4D: Integration of temporal information into CT angiography studies.

    Science.gov (United States)

    Haubenreisser, Holger; Bigdeli, Amir; Meyer, Mathias; Kremer, Thomas; Riester, Thomas; Kneser, Ulrich; Schoenberg, Stefan O; Henzler, Thomas

    2015-12-01

    CT angiography is the current clinical standard for the imaging many vascular illnesses. This is traditionally done with a single arterial contrast phase. However, advances in CT technology allow for a dynamic acquisition of the contrast bolus, thus adding temporal information to the examination. The aim of this article is to highlight the clinical possibilities of dynamic CTA using 2 examples. The accuracy of the detection and quantification of stenosis in patients with peripheral arterial occlusive disease, especially in stadium III and IV, is significantly improved when performing dynamic CTA examinations. The post-interventional follow-up of examinations of EVAR benefit from dynamic information, allowing for a higher sensitivity and specificity, as well as allowing more accurate classification of potential endoleaks. The described radiation dose for these dynamic examinations is low, but this can be further optimized by using lower tube voltages. There are a multitude of applications for dynamic CTA that need to be further explored in future studies.

  5. Usefulness of {sup 18}F fluoride PET/CT in breast cancer patients with osteosclerotic bone metastases

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seok Ho; Kim, Ku Sang; Kang, Seok Yun; Song, Hee Sung; Jo, Kyung Sook; Lee, Su Jin; Yoon, Joon Kee; An, Young Sil [Ajou Univ., Suwon (Korea, Republic of); Choi, Bong Hoi [Gyeongsang National Univ. Hospital, Jinju (Korea, Republic of)

    2012-03-15

    Bone metastasis is an important factor for the treatment and prognosis of breast cancer patients. Whole body bone scintigraphy (WBBS) can evaluate skeletal metastases, and {sup 18}F FDG PET/CT seems to exhibit high specificity and accuracy in detecting bone metastases. However, there is a limitation of {sup 18}F FDG PET in assessing sclerotic bone metastases because some lesions may be undetectable. Recent studies showed that {sup 18}F fluoride PET/CT is more sensitive than WBBS in detecting bone metastases. This study aims to evaluate the usefulness of {sup 18}F fluoride PET/CT by comparing it with WBBS and {sup 18}F FDG PET/CT in breast cancer patients with osteosclerotic skeletal metastases. Nine breast cancer patients with suspected bone metastases (9 females; mean age {+-} SD, 55.6{+-}10.0 years) underwent {sup 99m}Tc MDP WBBS, {sup 18}F FDG PET/CT and {sup 18}F fluoride PET/CT. Lesion based analysis of five regions of the skeletons(skull, vertebral column, thoracic cage, pelvic bones and long bones of extremities) and patient based analysis were performed. {sup 18}F fluoride PET/CT, {sup 18}F FDG PET/CT and WBBS detected 49, 20 and 25 true metastases, respectively. Sensitivity, specificity, positive predictive value and negative predictive value of {sup 18}F fluoride PET/CT were 94.2%, 46.3%, 57.7% and 91.2%, respectively. Most true metastatic lesions of {sup 18}F fluoride PET/CT had osteosclerotic change (45/49, 91.8%), and only four lesions showed osteolytic change. Most lesions on {sup 18}F FDG PET/CT also demonstrated osteosclerotic change (17/20, 85.0%) with three osteolytic lesions. All true metastatic lesions detected on WBBS and {sup 18}F FDG PET/CT were identified on {sup 18}F fluoride PET/CT. {sup 18}F FDG PET/CT in detecting osteosclerotic metastatic lesions. {sup 18}F fluoride PET/CT might be useful in evaluating osteosclerotic metastases in breast cancer patients.

  6. 3D-CT evaluation of secondary alveolar bone grafts in alveolar clefts

    Energy Technology Data Exchange (ETDEWEB)

    Naitoh, Hiroshi; Nishimura, Yoshihiko [Kyoto Univ. (Japan). Graduate School of Medicine; Yamawaki, Yoshiroh [Kyoto Katsura Hospital (Japan); Morimoto, Naoki [Kobe City General Hospital (Japan)

    2002-07-01

    From 1994 to 2000, we treated 116 patients with cleft alveolus by secondary alveolar bone grafts, and 48 of them were evaluated morphologically with 3D-CT. The frequency of successful bony bridging was significantly higher in the group whose grafts were completely enveloped (including the anterior alveolar ridge) with a mucoperiosteal flap. The frequency was also significantly higher in the group who underwent bone grafts at the age of 13 or less, and canine eruptions did not influence the ratio. Some cases showed such an improved growth pattern of grafted bone that the shape of the affected maxilla resembled that of the normal side, after long-term follow-up observations. The growth increment was remarkable in anterior maxillary height. Orthodontic management guides the canine or incisor into the reconstructed area of the previous cleft. We surmise that the new occlusal position puts pressure on the grafted bone and promotes further osteogenesis. These findings show that it is important to produce sufficient bony bridge to guide the canine or incisor, not the volume of grafted bone, in secondary alveolar bone grafts. Long-term follow-up observation, after more than 2-3 years, is also necessary to evaluate secondary alveolar bone grafts. (author)

  7. Characterizing bone marrow involvement in Hodgkin's lymphoma by FDG-PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Weiler-Sagie, Michal; Kagna, Olga [Rambam Health Care Campus, Nuclear Medicine Department, Haifa (Israel); Dann, Eldad J. [Rambam Health Care Campus and B. and R. Rappaport Faculty of Medicine, Technion, Hematology Department, Haifa (Israel); Ben-Barak, Ayelet [Rambam Health Care Campus and B. and R. Rappaport Faculty of Medicine, Technion, Pediatric Hemato-Oncology Department, Haifa (Israel); Israel, Ora [Rambam Health Care Campus and B. and R. Rappaport Faculty of Medicine, Technion, Nuclear Medicine Department, Haifa (Israel)

    2014-06-15

    Fluoro-deoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) is superior to iliac bone marrow biopsy (iBMB) for detection of bone marrow involvement (BMI) in staging of Hodgkin's lymphoma (HL). The present study aims to characterize the patterns and distribution of BMI in HL as determined by FDG-PET/CT. Reports of FDG-PET/CT studies performed for staging of HL were reviewed. BMI was defined as positive iBMB and/or foci of pathological FDG uptake in the skeleton that behaved in concordance with other sites of lymphoma in studies following chemotherapy. Number of FDG uptake foci, their specific location in the skeleton and the presence of corresponding lesions in the CT component of the study, and stage according to the Ann Arbor staging system, were recorded. The study included 473 patients. iBMB was performed in 336 patients. Nine patients had positive iBMB (9/336, 3 %). Seventy-three patients (73/473, 15 %) had FDG-PET/CT-defined BMI. The BM was the only extranodal site of HL in 52/473 patients (11 %). Forty-five patients had three or more foci of pathological skeletal FDG uptake (45/73, 62 %). Sixty-four patients (64/73, 88 %) had at least one uptake focus in the pelvis or vertebrae. In 60 patients (60/73, 82 %), the number of skeletal FDG uptake foci without corresponding CT lesions was equal to or higher than the number of foci with morphological abnormalities. FDG-PET/CT demonstrated BMI in 15 % of patients with newly diagnosed HL. Diagnosis of BMI in HL by FDG-PET/CT was more sensitive than iBMB with potential upstage in 11 % of patients. The most common pattern of FDG-PET/CT BMI was multifocal (at least three foci) skeletal FDG uptake, with at least one focus in the pelvis or vertebrae and no corresponding CT lesions. (orig.)

  8. TEMPORAL MODELING OF DNA DEGRADATION IN BONE REMAINS

    Directory of Open Access Journals (Sweden)

    Andrei Stefan

    2012-06-01

    Full Text Available The aim of this study is to follow the changes that occur, in time, at DNA level and to establish an efficient and reliable protocol for ancestral DNA extraction from bones found in archaeological sites. To test whether the protocol is efficient and capable of yielding good quality DNA, extraction was first performed on fresh bones. The material consists of fresh pig (Sus scrofa and cow (Bos taurus bones that were grounded by using a drill operating at low speed. The bone powder was then incubated in lysis buffer in the presence of proteinase K. DNA isolation and purification were done by using the phenol:chloroform protocol and DNA was precipitated with absolute ethanol stored at -20oC. The extractions were carried out once every month for a total of four extractions

  9. Squamous cell carcinoma of temporal bone: four case reports

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun Ha; Sung, Ki Joon; Sim, Young; Shim, Sue Yoen; Yoon, Byoung Moon [Wonju College of Medicine, Yonsei University, Wonju (Korea, Republic of)

    2000-04-01

    We report the CT findings of four cases of squamous cell carcinoma, paying special attention to the epicenter of the lesion and the pattern of bony destruction. All four patients had a past history of chronic otitis media. Squamous cell carcinoma affected mainly the hypotympanum and inferior wall of the external auditory canal. and in all cases revealed an irregular pattern of bony destruction. Irregular destruction of the tegmen tympani occurred in two cases. In cases of squamous cell carcinoma, CT findings suggesting involvement of the promontory are usually noted. (author)

  10. Detection of bone metastases in breast cancer patients in the PET/CT era: Do we still need the bone scan?

    Science.gov (United States)

    Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F

    2016-01-01

    To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  11. Quantification and visualization of alveolar bone resorption from 3D dental CT images

    Energy Technology Data Exchange (ETDEWEB)

    Nagao, Jiro; Mori, Kensaku; Kitasaka, Takayuki; Suenaga, Yasuhito [Nagoya University, Graduate School of Information Science, Nagoya (Japan); Yamada, Shohzoh; Naitoh, Munetaka [Aichi-Gakuin University, School of Dentistry, Nagoya (Japan)

    2007-06-15

    Purpose A computer aided diagnosis (CAD) system for quantifying and visualizing alveolar bone resorption caused by periodontitis was developed based on three-dimensional (3D) image processing of dental CT images. Methods The proposed system enables visualization and quantification of resorption of alveolar bone surrounding and between the roots of teeth. It has the following functions: (1) vertical measurement of the depth of resorption surrounding the tooth in 3D images, avoiding physical obstruction; (2) quantification of the amount of resorption in the furcation area; and (3) visualization of quantification results by pseudo-color maps, graphs, and motion pictures. The resorption measurement accuracy in the area surrounding teeth was evaluated by comparing with dentist's recognition on five real patient CT images, giving average absolute difference of 0.87 mm. An artificial image with mathematical truth was also used for measurement evaluation. Results The average absolute difference was 0.36 and 0.10 mm for surrounding and furcation areas, respectively. The system provides an intuitive presentation of the measurement results. Conclusion Computer aided diagnosis of 3D dental CT scans is feasible and the technique is a promising new tool for the quantitative evaluation of periodontal bone loss. (orig.)

  12. In vivo longitudinal micro-CT study of bent long limb bones in rat offspring.

    Science.gov (United States)

    De Schaepdrijver, Luc; Delille, Peter; Geys, Helena; Boehringer-Shahidi, Christian; Vanhove, Christian

    2014-07-01

    Micro-computed X-ray tomography (micro-CT) has been reported as a reliable method to assess ex vivo rat and rabbit fetal skeletons in embryo-fetal developmental toxicity studies. Since micro-CT is a non-invasive imaging modality it has the potential for longitudinal, in vivo investigation of postnatal skeletal development. This is the first paper using micro-CT to assess the reversibility of drug-induced bent long bones in a longitudinal study from birth to early adulthood in rat offspring. Analysis of the scans obtained on postnatal Day 0, 7, 21 and 80 showed complete recovery or repair of the bent long limb bones (including the scapula) within the first 3 weeks. When assessing risk the ability to demonstrate recovery is highly advantageous when interpreting such transient skeletal change. In summary, in vivo micro-CT of small laboratory animals can aid in non-clinical safety assessment, particularly for specific mechanistic purposes or to address a particular concern in developmental biology.

  13. Quantifying trabecular bone material anisotropy and orientation using low resolution clinical CT images: A feasibility study.

    Science.gov (United States)

    Nazemi, S Majid; Cooper, David M L; Johnston, James D

    2016-09-01

    Accounting for spatial variation of trabecular material anisotropy and orientation can improve the accuracy of quantitative computed tomography-based finite element (FE) modeling of bone. The objective of this study was to investigate the feasibility of quantifying trabecular material anisotropy and orientation using clinical computed tomography (CT). Forty four cubic volumes of interest were obtained from micro-CT images of the human radius. Micro-FE modeling was performed on the samples to obtain orthotropic stiffness entries as well as trabecular orientation. Simulated computed tomography images (0.32, 0.37, and 0.5mm isotropic voxel sizes) were created by resampling micro-CT images with added image noise. The gray-level structure tensor was used to derive fabric eigenvalues and eigenvectors in simulated CT images. For 'best case' comparison purposes, Mean Intercept Length was used to define fabric from micro-CT images. Regression was used in combination with eigenvalues, imaged density and FE to inversely derive the constants used in Cowin and Zysset-Curnier fabric-elasticity equations, and for comparing image derived fabric-elasticity stiffness entries to those obtained using micro-FE. Image derived eigenvectors (which indicated trabecular orientation) were then compared to orientation derived using micro-FE. When using clinically available voxel sizes, gray-level structure tensor derived fabric combined with Cowin's equations was able to explain 94-97% of the variance in orthotropic stiffness entries while Zysset-Curnier equations explained 82-88% of the variance in stiffness. Image derived orientation deviated by 4.4-10.8° from micro-FE derived orientation. Our results indicate potential to account for spatial variation of trabecular material anisotropy and orientation in subject-specific finite element modeling of bone using clinically available CT.

  14. Three-dimensional helical CT imaging of bone and joint diseases in the trunk and the hip joints. Pt. 1

    Energy Technology Data Exchange (ETDEWEB)

    Gong Hohghan [Jangxi Medical Coll. (China). First Affiliated Hospital; Hiraishi, Kumiko; Doi, Miwako; Matsui, Ritsuo; Simizu, Tadafumi; Sueyoshi, Kouzou; Narabayashi, Isamu

    1997-12-01

    To confirm the utility of CT scan images for orthopedic surgeons managing patients with complex disorders, we have produced and studied three-dimensional images from helical CT scans of 28 patients with various bone and joint disorders in the trunk and the hip joint. The CT scanner employed was a Toshiba X-force, and the 3D-CT images were constructed on an X-link50. The 3D images obtained could be observed from various projections. Congenital vertebral malformations, spondylosis, OPLL, osteonecrosis, fractures, and bone tumors were examined, and the 3D helical CT images brought useful information to bear on the spatial location and extent of the lesions. Therefore, 3D helical CT should become an indispensable tool for both preoperative examination and post-operative follow-up studies in orthopedic surgery. (author)

  15. Temporal Bone Osteomyelitis: The Relationship with Malignant Otitis Externa, the Diagnostic Dilemma, and Changing Trends

    Directory of Open Access Journals (Sweden)

    Jia-Cheng Chen

    2014-01-01

    Full Text Available Fifty-five patients hospitalized for osteomyelitis of the temporal bone between 1990 and 2011 were divided into two study groups: group 1 was patients collected from 1990 to 2001 and group 2 was composed of patients between 2002 and 2011. Clinical diagnostic criteria and epidemiologic data were analyzed to illustrate the altering features of osteomyelitis of the temporal bone. Group 1 patients were characterized by high prevalence of diabetes and more commonly suffered from otalgia, otitis externa and granulation tissue in the external auditory canal and higher positive culture for Pseudomonas aeruginosa. Noticeable changing trends were found between both groups, including declining prevalence of diabetes, fewer patients complaining of pain or presenting with otitis externa, and canal granulation, and increased variety of pathogens in group 2. We should highlight the index of clinical suspicion for osteomyelitis of the temporal bone, even in nondiabetic or immunocompetent patients. Painless otorrhea patients were also at risk of osteomyelitis of the temporal bone, especially patients with previous otologic operation. Increased multiplicity of pathogens amplified the difficulty of diagnosis for osteomyelitis of the temporal bone.

  16. Temporal bone osteomyelitis: the relationship with malignant otitis externa, the diagnostic dilemma, and changing trends.

    Science.gov (United States)

    Chen, Jia-Cheng; Yeh, Chien-Fu; Shiao, An-Suey; Tu, Tzong-Yang

    2014-01-01

    Fifty-five patients hospitalized for osteomyelitis of the temporal bone between 1990 and 2011 were divided into two study groups: group 1 was patients collected from 1990 to 2001 and group 2 was composed of patients between 2002 and 2011. Clinical diagnostic criteria and epidemiologic data were analyzed to illustrate the altering features of osteomyelitis of the temporal bone. Group 1 patients were characterized by high prevalence of diabetes and more commonly suffered from otalgia, otitis externa and granulation tissue in the external auditory canal and higher positive culture for Pseudomonas aeruginosa. Noticeable changing trends were found between both groups, including declining prevalence of diabetes, fewer patients complaining of pain or presenting with otitis externa, and canal granulation, and increased variety of pathogens in group 2. We should highlight the index of clinical suspicion for osteomyelitis of the temporal bone, even in nondiabetic or immunocompetent patients. Painless otorrhea patients were also at risk of osteomyelitis of the temporal bone, especially patients with previous otologic operation. Increased multiplicity of pathogens amplified the difficulty of diagnosis for osteomyelitis of the temporal bone.

  17. Evaluation of facial nerve and its landmarks in adult temporal bones

    Directory of Open Access Journals (Sweden)

    Saeid Soheilipour

    2010-06-01

    Full Text Available Introduction: The aim of this study was to identify variations of different segments of facial nerve in temporal bone. Materials and Methods: In this descriptive study that conducted on drilled bones in the temporal bone center of the Al-Zahra Hospital of Isfahan University of Medical Sciences, the landmarks of facial nerve in temporal bone were identified as separate variables and their distances from outer cortex of temporal bone and Henles spine and distances between different segments of nerve were recorded. Results: In the 50 temporal bones dissected, the distance between the tip of incus short process to the cortex was 14.2±1.96 mm, the distance between the facial recess from the facial nerve to the cortex was 14.5±2.58 mm, the distance between the stylomastoid foramen to the cortex was 20.6±2.49 mm, the distance between the lateral semicircular canal to the cortex was 15.9±2.31 mm and the distance between the sigmoid sinus dome to the cortex was 14.08±2.83 mm. The mean length of tympanic and mastoid segments (2nd and 3rd segments of facial nerve were 11.35±0.68 mm and 13.28±1.11mm, respectively. Conclusion: The mean lengths of segment of facial nerve and distant of landmarks from outer cortex of temporal bone are partially similar compared to those described in the western literature and text books, but different compared to eastern researches.

  18. Evaluation of bone changes in the temporomandibular joint using cone beam CT

    Science.gov (United States)

    dos Anjos Pontual, ML; Freire, JSL; Barbosa, JMN; Frazão, MAG; dos Anjos Pontual, A; Fonseca da Silveira, MM

    2012-01-01

    Objective The aim of this study was to assess bone changes and mobility in temporomandibular joints (TMJs) using cone beam CT (CBCT) in a population sample in Recife, PE, Brazil. Methods The TMJ images of patients treated by a radiologist at a private dental radiology service over a period of 1 year were retrieved from the computer database and assessed using a computer with a 21-inch monitor and the iCAT Cone Beam 3D Dental Imaging System Workstation program (Imaging Sciences International, Hatfield, PA). The Pearson χ2 test was used to analyse the differences in percentage of bone changes among the categories of mobility (p ≤ 0.05). The McNemar test was used to compare the presence of bone changes in TMJs on the right and left sides (p ≤ 0.05). Results An adjusted logistic regression model was used to assess the effect of age and gender on the occurrence of bone changes (p ≤ 0.05). Bone changes were present in 227 (71%) patients. Age group and gender showed a statistically significant association with presence of bone changes (p ≤ 0.05). There was no significant difference between the right and left sides (p = 0.556) and in condylar mobility (p = 0.925) with regard to the presence of degenerative bone changes. Conclusions There is a high prevalence of degenerative bone alteration in TMJs, which is more frequent in women and mostly located in the condyle. The prevalence of degenerative bone changes increases with age. There is no correlation between condylar mobility and the presence of degenerative bony changes in TMJs. PMID:22184625

  19. CT evaluation of local leakage of bone cement after percutaneous kyphoplasty and vertebroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lee, In Jae; Choi, A. Lam; Yie, Mi-Yeon; Yoon, Ji Young; Jeon, Eui Yong; Koh, Sung Hye; Yoon, Dae Young; Lim, Kyung Ja (Dept. of Radiology, Hallym Univ. Sacred Heart Hospital, Seoul (Korea)), e-mail: ijlee2003@medimail.co.kr; Im, Hyoung June (Dept. of Occupational Medicine, Hallym Univ. College of Medicine, Seoul (Korea))

    2010-07-15

    Background: Percutaneous injection of bone cement (acrylic cement) during percutaneous kyphoplasty and vertebroplasty can cause symptomatic or asymptomatic complications due to leakage, extravasation or vascular migration of cement. Purpose: To investigate and to compare the incidence and site of local leakage or complications of bone cement after percutaneous kyphoplasty and vertebroplasty using bone cement. Material and Methods: We retrospectively reviewed 473 cases of percutaneous kyphoplasty or vertebroplasty performed under fluoroscopic guidance. Of the 473 cases, follow-up CT scans that covered the treated bones were available for 83 cases (59 kyphoplasty and 24 vertebroplasty). Results: The rate of local leakage of bone cement was 87.5% (21/24) for percutaneous vertebroplasty and 49.2% (29/59) for kyphoplasty. The most common site of local leakage was perivertebral soft tissue (n=8, 38.1%) for vertebroplasty. The most common site of local leakage was a perivertebral vein (n=7, 24.1%) for kyphoplasty. Two cases of pulmonary cement embolism developed: one case after kyphoplasty and one case after vertebroplasty. Conclusion: Local leakage of bone cement was more common for percutaneous vertebroplasty compared with kyphoplasty (P<0.005). The most common sites of local leakage were perivertebral soft tissue and perivertebral vein.

  20. Osteoarthritic versus osteoporotic bone and intra‐skeletal variations in normal bone: Evaluation with µCT and bone histomorphometry

    National Research Council Canada - National Science Library

    Zupan, Janja; van't Hof, Rob J; Vindišar, Franci; Haring, Gregor; Trebše, Rihard; Komadina, Radko; Marc, Janja

    2013-01-01

    ...) and microcomputed tomography (µCT) as well as DXA in order to first, test the differences between OA and OP comparing both groups to healthy controls, second, to assess variations between three different skeletal sites in controls...

  1. Spine metastases in prostate cancer: comparison of technetium‐99m‐MDP whole‐body bone scintigraphy, [18F]choline positron emission tomography(PET)/computed tomography (CT) and [18F]NaF PET/CT

    National Research Council Canada - National Science Library

    Poulsen, Mads H; Petersen, Henrik; Høilund‐Carlsen, Poul F; Jakobsen, Jørn S; Gerke, Oke; Karstoft, Jens; Steffansen, Signe I; Walter, Steen

    2014-01-01

    ... (PET)/computed tomography (CT) and [(18) F]-fluoromethylcholine (FCH) PET/CT. The study entry criteria were biopsy-proven prostate cancer, a positive WBS consistent with bone metastases, and no history of androgen deprivation...

  2. Computed tomography of the pathological temporal bone. Malformations. Otospongiosis

    Energy Technology Data Exchange (ETDEWEB)

    Azais, O.; Drouineau, J.; Vandermarcq, P.; Barret, D.; Gasquet, C.

    1988-01-01

    The authors evaluate the value of computed tomography in the investigation of malformations and otospongiosis of the ear. Although the CT scan appears to be essential in the preoperative of malformations of the ear, especially as otological examination frequently contributes little to the evaluation of the middle ear, otospongiosis seems to be a less formal indication, except in the predominantly cochlear forms of the disease.

  3. Bilateral Facial Paralysis Caused by Temporal Bone Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Ghiasi

    2016-02-01

    Full Text Available Introduction Although bilateral facial nerve palsy is a rare condition, its etiology is more detectable than the unilateral type. A temporal bone fracture is one cause of bilateral facial nerve palsy, contributing in 3% of the cases. Case Presentation Here, we report the case of a 35-year-old man complaining of bilateral incomplete eye closure, two weeks after a closed head injury caused by a motor vehicle accident. Conclusions The high resolution computed tomography findings revealed a bilateral temporal bone fracture line, which extended to the fallopian canal. With regard to treatment, near complete recovery was obvious after two weeks of treatment with oral corticosteroids. Overall, bilateral facial palsy is hard to diagnose; therefore, clinical suspicion and the early detection of facial nerve injuries is necessary for good nerve recovery in temporal bone fractures.

  4. The application of micro-CT in monitoring bone alterations in tail-suspended rats in vivo

    Science.gov (United States)

    Luan, Hui-Qin; Sun, Lian-Wen; Huang, Yun-Fei; Wang, Ying; McClean, Colin J.; Fan, Yu-Bo

    2014-06-01

    Osteopenia is a pathological process that affects human skeletal health not only on earth but also in long-time spaceflight. Micro-computed tomography (micro-CT) is a nondestructive method for assessing both bone quantity and bone quality. To investigate the characteristics of micro-CT on evaluating the microgravity-induced osteopenia (e.g. early detection time and the sensitive parameters), the bone loss process of tail-suspended rats was monitored by micro-CT in this study. 8-Week-old female Sprague Dawley rats were divided into two groups: tail suspension (TS) and control (CON). Volumetric bone mineral density (vBMD) and microstructure of the femur and tibia were evaluated in vivo by micro-CT at 0, 7, 14, 22 days. Biomechanical properties of the femur and tibia were determined by three-point bending test. The ash weight of bone was also investigated. The results showed that (1) bone loss in the proximal tibia appeared earlier than in the distal femur. (2) On day 7, the percent bone volume (BV/TV) of the tibia 15.44% decreased significantly, and the trabecular separation (Tb.Sp) 30.29% increased significantly in TS group, both of which were detected earlier than other parameters. (3) Biomechanical properties (e.g. femur, -22.4% maximum load and -23.75% Young’s modulus vs. CON) and ash weight of the femur and tibia decreased significantly in the TS group in comparison to CON group. (4) vBMD of the femur and tibia were clearly related to bone ash and dry weight (r = 0.75-0.87, p bone loss induced by tail suspension, moreover, trabecular vBMD and other parameters might be used to evaluate bone strength. Therefore, micro-CT is a reliable and sensitive method for predicting unloading-induced bone loss in small animals.

  5. Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients

    Energy Technology Data Exchange (ETDEWEB)

    Morhard, Dominik; Fink, Christian; Becker, Christoph; Reiser, Maximilian F.; Nikolaou, Konstantin [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology, Munich (Germany)

    2008-05-15

    Non-contrast-enhanced cranial computed tomography (NECT) and CT angiography (CTA) are the most frequently used modalities in the triage of patients with acute ischemic and hemorrhagic stroke. CTA bone removal can improve the delineation of vasculature closely adjacent to bony structures, which is sometimes limited in standard CTA. The aim of this study was the evaluation of the clinical benefit of bone subtraction (BS) regarding delineation of cerebral vasculature, reading time and depiction of vascular pathologies compared to standard CTA without BS. A total of 100 patients who underwent NECT and supraaortic CTA on a 64-slice CT system were retrospectively included in the study. Bone removal was performed by subtraction of the NECT data from the CTA data using a dedicated workstation. Standard and BS CTA of each patient was reviewed for delineation of cerebral vasculature (grading scale from 1 = 'excellent delineation' to 10 = 'hardly any delineation'), reading time and depiction of vascular pathologies (standardized catalog) by two blinded readers. For BS data sets, the quality of BS was rated by a combination of the criteria complete bone removal, depiction of vascular structures and sufficient quality for diagnostic evaluation. The use of BS significantly reduced reading time from 4.60 min to 3.49 min (p < 0.001). Performing BS, the quality of vascular delineation of the cerebral arteries, cerebral veins and cavernous segment of the ICA increased significantly as compared to standard CTA (1.70 vs. 2.70; 2.60 vs. 4.12; 2.35 vs. 4.40, all p < 0.001). Consensus reading showed 41 pathologies in 35 patients. Diagnosis was missed or wrong overall in 15 cases, with 3 missed aneurysms (CTA: 2 vs. BS: 1), 8 wrong stenotic findings (CTA: 3 vs. BS: 5) and 4 missed partial thromboses (CTA: 2 vs. BS: 2). Performing BS in supraaortic CTA for the evaluation of cerebral vasculature reduces reading time and improves delineation of vessels. Diagnostic

  6. CT analysis of the upper end of the femur: the asterisk sign and ischaemic bone necrosis of the femoral head.

    Science.gov (United States)

    Dihlmann, W

    1982-01-01

    In computed tomography (CT) of the head of the femur, a star-shaped structure can be seen which we refer to as the asterisk or asterisk sign. The asterisk is formed by thickened weight-bearing bone trabeculae. It can be shown by CT that the asterisk exhibits a characteristic change in ischaemic bone necrosis of the femoral head, even when the disease is in an early stage. CT of the hip joint is therefore an important examination for early diagnosis of ischaemic disease of the femoral head.

  7. Accuracy of bone SPECT/CT for identifying hardware loosening in patients who underwent lumbar fusion with pedicle screws

    Energy Technology Data Exchange (ETDEWEB)

    Hudyana, Hendrah; Maes, Alex [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Hospital Leuven, Department of Morphology and Medical Imaging, Leuven (Belgium); Vandenberghe, Thierry; Fidlers, Luc [AZ Groeninge, Department of Neurosurgery, Kortrijk (Belgium); Sathekge, Mike [University of Pretoria, Department of Nuclear Medicine, Pretoria (South Africa); Nicolai, Daniel [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2016-02-15

    The aim of this retrospective study was to evaluate the accuracy of bone SPECT (single photon emission computed tomography)/CT (computed tomography) in diagnosing loosening of fixation material in patients with recurrent or persistent back pain that underwent lumbar arthrodesis with pedicle screws using surgery and clinical follow-up as gold standard A total of 48 patients (median age 49 years, range 21-81 years; 17 men) who had undergone lumbar spinal arthrodesis were included in this retrospective analysis. SPECT/CT results were compared to the gold standard of surgical evaluation or clinical follow-up. Positive SPECT/CT results were considered true positives if findings were confirmed by surgery or if clinical and other examinations were completely consistent with the positive SPECT/CT finding. They were considered false positives if surgical evaluation did not find any loose pedicle screws or if symptoms subsided with non-surgical therapy. Negative SPECT/CT scans were considered true negatives if symptoms either improved without surgical intervention or remained stable over a minimum follow-up period of 6 months. Negative SPECT/CT scans were determined to be false negatives if surgery was still required and loosening of material was found. The median length of time from primary surgery to bone SPECT/CT referral was 29.5 months (range 12-192 months). Median follow-up was 18 months (range 6-57) for subjects who did not undergo surgery. Thirteen of the 48 patients were found to be positive for loosening on bone SPECT/CT. Surgical evaluation (8 patients) and clinical follow-up (5 patients) showed that bone SPECT/CT correctly predicted loosening in 9 of 13 patients, while it falsely diagnosed loosening in 4 patients. Of 35 negative bone SPECT/CT scans, 12 were surgically confirmed. In 18 patients, bone SPECT/CT revealed lesions that could provide an alternative explanation for the symptoms of pain (active facet degeneration in 14 patients, and disc and sacroiliac

  8. Validation of Cross-calibration Schemes for Quantitative Bone SPECT/CT Using Different Sources under Various Geometric Conditions.

    Science.gov (United States)

    Miyaji, Noriaki; Miwa, Kenta; Motegi, Kazuki; Umeda, Takuro; Wagatsuma, Kei; Fukai, Shohei; Takiguchi, Tomohiro; Terauchi, Takashi; Koizumi, Mitsuru

    Several cross-calibration schemes have been proposed to produce quantitative values in bone SPECT imaging. Differences in the radionuclide sources and geometric conditions can decrease the accuracy of cross-calibration factor (CCF). The present study aimed to validate the effects of calibration schemes using different sources under various geometric conditions. Temporal variations as well as variations in acquisition counts and the shapes of (57)Co standard and (99m)Tc point sources and a (99m)Tc disk source were determined. The effects of the geometric conditions of the source-to-camera distance (SCD) and lateral distance on the CCF were investigated by moving the camera or source away from the origin. The system planar sensitivity of NEMA incorporated into a Symbia Intevo SPECT/CT device (Siemens®) was defined as reference values. The temporal variation in CCF using the (57)Co source was relatively stable within the range of 0.7% to 2.3%, whereas the (99m)Tc source ranged from 2.7% to 7.3%. In terms of source shape, the (57)Co standard point source was the most stable. Both SCD and lateral distance decreased as a function of distance from the origin. Errors in the geometric condition were higher for the (57)Co standard point source than the (99m)Tc disk source. Different calibration schemes influenced the reliability of quantitative values. The (57)Co standard point source was stable over a long period, and this helped to maintain the quality of quantitative SPECT/CT imaging data. The CCF accuracy of the (99m)Tc source decreased depending on the preparative method. The method of calibration for quantitative SPECT should be immediately standardized to eliminate uncertainty.

  9. Three-dimensional visualization and characterization of bone structure using reconstructed in-vitro μCT images: A pilot study for bone microarchitecture analysis

    Energy Technology Data Exchange (ETDEWEB)

    Latief, Fourier Dzar Eljabbar, E-mail: fourier@fi.itb.ac.id [Physics of Earth and Complex Systems, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia); Dewi, Dyah Ekashanti Octorina [2Biomedical Engineering Research Division, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Jl. Ganesha 10, Bandung 40132 (Indonesia); Shari, Mohd Aliff Bin Mohd [Faculty of Electrical Engineering, Universiti Teknologi MARA Malaysia, 40000 Shah Alam, Selangor (Malaysia)

    2014-03-24

    Micro Computed Tomography (μCT) has been largely used to perform micrometer scale imaging of specimens, bone biopsies and small animals for the study of porous or cavity-containing objects. One of its favored applications is for assessing structural properties of bone. In this research, we perform a pilot study to visualize and characterize bone structure of a chicken bone thigh, as well as to delineate its cortical and trabecular bone regions. We utilize an In-Vitro μCT scanner Skyscan 1173 to acquire a three dimensional image data of a chicken bone thigh. The thigh was scanned using X-ray voltage of 45 kV and current of 150 μA. The reconstructed images have spatial resolution of 142.50 μm/pixel. Using image processing and analysis e.i segmentation by thresholding the gray values (which represent the pseudo density) and binarizing the images, we were able to visualize each part of the bone, i.e., the cortical and trabecular regions. Total volume of the bone is 4663.63 mm{sup 3}, and the surface area of the bone is 7913.42 mm{sup 2}. The volume of the cortical is approximately 1988.62 mm{sup 3} which is nearly 42.64% of the total bone volume. This pilot study has confirmed that the μCT is capable of quantifying 3D bone structural properties and defining its regions separately. For further development, these results can be improved for understanding the pathophysiology of bone abnormality, testing the efficacy of pharmaceutical intervention, or estimating bone biomechanical properties.

  10. A CASE REPORT OF POST-TRAUMATIC CHOLESTEATOMA FOLLOWING TEMPORAL BONE FRACTURE

    Directory of Open Access Journals (Sweden)

    Vijay

    2016-05-01

    Full Text Available We report a case of chronic suppurative otitis media squamous disease following temporal bone fracture. Patient had road traffic accident and longitudinal fracture with facial palsy four years back with recent onset ear discharge. Upon further evaluation, patient was found to have attic cholesteatoma which was managed with canal wall down mastoidectomy and type IV tympanoplasty. We would like to recommend a longterm follow-up in all cases of temporal bone fracture even with a negative history of prior ear discharge or hard of hearing.

  11. [Comparison of quality on digital X-ray devices with 3D-capability for ENT-clinical objectives in imaging of temporal bone and paranasal sinuses].

    Science.gov (United States)

    Knörgen, M; Brandt, S; Kösling, S

    2012-12-01

    Comparison of dosage and spatial resolution of digital X-Ray devices with 3D-capability in head and neck imaging. Three on-site X-Ray devices, a general purpose multi-slice CT (CT), a dedicated cone-beam CT (CBCT) and the CT-mode of a device for digital angiography (DSA) of the same generation were compared using paranasal sinus (PNS) and temporal bone imaging protocols. The radiation exposure was measured with a puncture measuring chamber on a CTDI head phantom as well as with chip-strate-dosimeters on an Alderson head phantom in the regions of the eyes and thyroid gland. By using the Alderson head phantom, the specific dosage of the X-Ray device with regard to different protocols was read out. For the assessment of the high-contrast resolution of the devices, images of a self-made phantom were qualitatively analysed by six observers. The three devices showed marked variations in the dosage and spatial resolution depending on the protocol and/or modus. In both parameters, CBCT was superior to CT and DSA using standard protocols, with the difference being less obvious for the investigation with PNS. For high-contrast investigations CBCT CT is a remarkable option in head and neck radiology. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Differential diagnosis of osteoblastic metastases from bone islands in patients with lung cancer by single-source dual-energy CT: Advantages of spectral CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Yue, E-mail: dyy1026@sina.com [Department of Radiology, The First Affiliated Hospital of Dalian Medical University, LiaoNing 116011 (China); Zheng, Shaowei, E-mail: chouxiong@sohu.com [Department of Radiology, The First Affiliated Hospital of Dalian Medical University, LiaoNing 116011 (China); Machida, Haruhiko, E-mail: machira@dnh.twmu.ac.jp [Department of Radiology, Tokyo Women' s Medical University Medical Center East, Tokyo 116-8567 (Japan); Wang, Bing, E-mail: wangbing19831003@163.com [Department of Radiology, The First Affiliated Hospital of Dalian Medical University, LiaoNing 116011 (China); Liu, Ailian, E-mail: dmu_liuailian@126.com [Department of Radiology, The First Affiliated Hospital of Dalian Medical University, LiaoNing 116011 (China); Liu, Yijun, E-mail: yijunliu1965@126.com [Department of Radiology, The First Affiliated Hospital of Dalian Medical University, LiaoNing 116011 (China); Zhang, Xin, E-mail: zhhw2000@126.com [Department of Nuclear Medicine, The First Affiliated Hospital of Dalian Medical University, Liaoning 116011 (China)

    2015-05-15

    Highlights: • Spectral CT were useful for the follow-up of spinal lesions in patients with lung cancer. • Spectral CT were useful for more accurate differential diagnosis of OBMs and BIs. • 110 keV virtual monochromatic images were the optimal for providing this differentiation. - Abstract: Objectives: To evaluate the diagnostic efficacy of spectral CT for the differentiation of osteoblastic metastases (OBMs) from bone islands (BIs) in patients with lung cancer. Methods: In 94 patients with lung cancer who underwent spectral CT, focal hyperdense lesions in vertebral bodies were diagnosed as OBMs or BIs. Regions of interest were placed within each lesion to measure the mean CT value and its standard deviation (SD) on polychromatic single-energy CT (SECT) at 140 kVp and dual-energy virtual monochromatic spectral (VMS) images. The mean bone (D{sub bone(wa)}) and water densities (D{sub wa(bone)}) of each lesion were also measured. The slope (k) of the spectral curve was calculated. Independent-sample t-test was used to compare those values between OBMs and BIs. Receiver operator characteristic analysis was performed to compare the area under curve (AUC) for the differentiation of OBMs from BIs. Results: A total of 79 OBMs and 43 BIs were confirmed. The CT and SD values on SECT at 140 kVp and VMS images at 50–130 keV, k value, and D{sub bone(wa)} for OBMs were significantly lower than for BIs; D{sub wa(bone)} was significantly higher for OBMs than for BIs (p < 0.05 for all). The AUC for the SD value at 110 keV was the highest among those parameters. The optimal cut-off value for this differentiation was 68.6 HU for the SD value on VMS images at 110 keV with sensitivity of 93.0% and specificity of 93.3%. Conclusion: Spectral CT is helpful for the differentiation of OBMs from BIs in patients with lung cancer, particularly using SD of the CT value on high-energy VMS images.

  13. On estimating the directionality distribution in pedicle trabecular bone from micro-CT images.

    Science.gov (United States)

    Gdyczynski, Catherine M; Manbachi, Amir; Hashemi, SayedMasoud; Lashkari, Bahman; Cobbold, Richard S C

    2014-12-01

    Our interest in the trabecular alignment within bone stems from the need to better understand the manner in which it can affect ultrasound propagation, particularly in pedicles. Within long bones it is well established that trabecular structures are aligned in an organized manner associated with the direction of load distribution; however, for smaller bones there are limited alignment studies. To investigate the directionality distribution in a quantitative manner we used a micro-CT to obtain three-dimensional (3D) structural data and developed analytical methods based on the special properties of Gabor filters. Implementation of these techniques has been developed and tested on a variety of simulated images as well as on 3D structures whose geometry is well-defined. To test the use of this technique we compared the results obtained on vertebral body trabecular bone with visual directionality and previous measurements by others. The method has been applied to six human pedicle samples in two orthogonal planes with results that provide reasonable proof-of-principle evidence that the method is well suited for estimating the directionality distribution within pedicle bones.

  14. Methodologies for Development of Patient Specific Bone Models from Human Body CT Scans

    Science.gov (United States)

    Chougule, Vikas Narayan; Mulay, Arati Vinayak; Ahuja, Bharatkumar Bhagatraj

    2016-06-01

    This work deals with development of algorithm for physical replication of patient specific human bone and construction of corresponding implants/inserts RP models by using Reverse Engineering approach from non-invasive medical images for surgical purpose. In medical field, the volumetric data i.e. voxel and triangular facet based models are primarily used for bio-modelling and visualization, which requires huge memory space. On the other side, recent advances in Computer Aided Design (CAD) technology provides additional facilities/functions for design, prototyping and manufacturing of any object having freeform surfaces based on boundary representation techniques. This work presents a process to physical replication of 3D rapid prototyping (RP) physical models of human bone from various CAD modeling techniques developed by using 3D point cloud data which is obtained from non-invasive CT/MRI scans in DICOM 3.0 format. This point cloud data is used for construction of 3D CAD model by fitting B-spline curves through these points and then fitting surface between these curve networks by using swept blend techniques. This process also can be achieved by generating the triangular mesh directly from 3D point cloud data without developing any surface model using any commercial CAD software. The generated STL file from 3D point cloud data is used as a basic input for RP process. The Delaunay tetrahedralization approach is used to process the 3D point cloud data to obtain STL file. CT scan data of Metacarpus (human bone) is used as the case study for the generation of the 3D RP model. A 3D physical model of the human bone is generated on rapid prototyping machine and its virtual reality model is presented for visualization. The generated CAD model by different techniques is compared for the accuracy and reliability. The results of this research work are assessed for clinical reliability in replication of human bone in medical field.

  15. Diffuse Hypermetabolism at Bone Marrow in F-18 FDG PET/CT: Correlation with Bone Marrow Biopsy and Complete Blood Cell Counts

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Hee; Lim, Seok Tae; Jeong, Young Jin; Kim, Dong Wook; Jeong, Hwan Jeong; Sohn, Myung Hee [Chonbuk National University Medical School, Jeonju (Korea, Republic of)

    2009-02-15

    Increased FDG uptake in the bone marrow has been reported in patients taking erythropoietin or granulocyte-colony stimulating factor (G-CSF). The aim of this study is to investigate the correlation between F-18 FDG uptake in the bone marrow and bone marrow finding, hematological parameters. Twenty patients who had diffuse FDG uptake at the bone marrow and received hematological examinations, bone marrow biopsy within 10 days before or after PET/CT were enrolled in this study. Among them, 11 patients were excluded; 4 patients received G-CSF or erythropoietin before PET/CT. Seven patients showed definite pathology in a bone marrow biopsy. The parameters included the measurement of WBC, hemoglobin, platelet and cellularity of the bone marrow. Bone marrow FDG uptake was correlated with a low hemoglobin but not WBC, platelet. Histopathologic findings in marrow biopsies were various: normal finding (n=3), hyperplasia of granulocytic cells (n=2), eosinophilic hyperplasia (n=1), reactive lymphoid nodules (n=1), hypercelluar marrow (n=1), hypocelluar marrow (n=1). All patients except two, showed normal marrow celluarity. FDG uptake by bone marrow correlated with anemia but not WBC, platelet, bone marrow cellularity.

  16. Intravenous contrast injection significantly affects bone mineral density measured on CT

    Energy Technology Data Exchange (ETDEWEB)

    Pompe, Esther; Willemink, Martin J.; Dijkhuis, Gawein R.; Verhaar, Harald J.J.; Hoesein, Firdaus A.A.M.; Jong, Pim A. de [University Medical Center Utrecht, Department of Radiology and Internal Medicine-Geriatrics, Postbus 85500, Postbox: E.03.511, GA, Utrecht (Netherlands)

    2014-09-05

    The objective is to evaluate the effect of intravenous contrast media on bone mineral density (BMD) assessment by comparing unenhanced and contrast-enhanced computed tomography (CT) examinations performed for other indications. One hundred and fifty-two patients (99 without and 53 with malignant neoplasm) who underwent both unenhanced and two contrast-enhanced (arterial and portal venous phase) abdominal CT examinations in a single session between June 2011 and July 2013 were included. BMD was evaluated on the three examinations as CT-attenuation values in Hounsfield Units (HU) in the first lumbar vertebra (L1). CT-attenuation values were significantly higher in both contrast-enhanced phases, compared to the unenhanced phase (p < 0.01). In patients without malignancies, mean ± standard deviation (SD) HU-values increased from 128.8 ± 48.6 HU for the unenhanced phase to 142.3 ± 47.2 HU for the arterial phase and 147.0 ± 47.4 HU for the portal phase (p < 0.01). In patients with malignancies, HU-values increased from 112.1 ± 38.1 HU to 126.2 ± 38.4 HU and 130.1 ± 37.3 HU (p < 0.02), respectively. With different thresholds to define osteoporosis, measurements in the arterial and portal phase resulted in 7-25 % false negatives. Our study showed that intravenous contrast injection substantially affects BMD-assessment on CT and taking this into account may improve routine assessment of low BMD in nonquantitative CT. (orig.)

  17. Pulmonary infections following bone marrow transplantation: High-resolution CT findings in 35 paediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Davaus Gasparetto, Taisa [Department of Diagnostic Radiology of the Federal Universitie Fluminense, Niteroi (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)], E-mail: taisadavaus@gmail.com; Escuissato, Dante L. [Department of Diagnostic Radiology of the University of Parana, Curitiba (Brazil); Marchiori, Edson [Department of Diagnostic Radiology of the Federal Universitie Fluminense, Niteroi (Brazil); Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2008-04-15

    Purpose: The purpose of this study was to assess the high-resolution CT findings of paediatric patients who had pulmonary infections following bone marrow transplantation (BMT), and to evaluate the differential diagnosis through high-resolution CT of the various pathogens responsible for pulmonary infections after BMT. Patients and methods: The study included 35 consecutive patients who had documented pulmonary infection, high-resolution CT of the chest performed within 24 h of the beginning of symptoms, and proven diagnosis within 1 week of the onset of symptoms. The pulmonary infections were due to viruses (n = 16), bacteria (n = 9), fungi (n = 9), and protozoa (n = 1). Two radiologists analyzed the CT scans and reached final decisions regarding the findings by consensus. Results: Four patients with confirmed pneumonia had normal high-resolution CT scans. Regarding the viral infections, the most frequent features were areas of ground-glass attenuation (43.7%) and small centrilobular nodules (31.2%). Airspace consolidation (88.9%), small centrilobular nodules (22.2%) and ground-glass attenuation (22.2%) were the most frequent findings in patients with bacterial pneumonia following BMT. Large nodules were seen in 66.7% of the patients with fungal pneumonia, and in only one case of virus infection. The 'halo sign' (n = 5) was seen only in patients with fungal pneumonia. Conclusion: In conclusion, the main causes of pulmonary infection in paediatric patients following BMT share similar high-resolution CT findings. Large nodules and 'halo sign' are more common in patients with fungal infections.

  18. Displasia fibrosa do osso temporal: relato de dois casos Fibrous dysplasia of the temporal bone: report of two cases

    Directory of Open Access Journals (Sweden)

    Roberto Claudio B. Oliveira

    2004-10-01

    Full Text Available A displasia fibrosa do osso temporal é uma doença de etiologia ainda controversa, manifestando-se principalmente por estenose progressiva do conduto auditivo externo e pela perda condutiva da audição. Outras manifestações incluem abaulamento na região temporal ou retroauricular, otorréia, otalgia e disacusia sensório-neural. A incidência é maior no sexo masculino e acomete principalmente a raça branca. O exame radiológico característico demonstra um aspecto de "vidro-fosco" homogêneo envolvido por uma concha de tecido cortical denso, embora existam outros padrões radiológicos desta enfermidade. O exame microscópico demonstra um trabeculado ósseo semelhante aos caracteres chineses. Este estudo relata dois casos de displasia fibrosa do osso temporal que se destacam, pois ultrapassaram o osso temporal, acometendo a região zigomática, sendo que no segundo caso houve também comprometimento do osso esfenóide e o pterigóide. Os pacientes foram submetidos à mastoidectomia radical modificada e tiveram boa evolução.Fibrous dysplasia of the temporal bone (FDTB is a disorder which etiology is still controversial. Its main clinical feature is a progressive narrowing of the external auditory canal following by conductive hearing loss. Temporal or retroauricular enlargement, ear discharge, otalgia, and sensorineural hearing loss are additional findings. Women and Caucasians are more affected. The prominent finding is a homogeneous radiodense "grounded glass" like image shell surrounded by dense cortical tissue. However, other radiological patterns of this disease may be displayed. Microscopically, a trabecular of bone in "Chinese letter" configuration is found. The two cases of FDTB herein reported are particularly special for a far beyond temporal commitment reaching the zygomatic area in the first case and sphenoid and pterygoid bones in the second one. This infrequent clinical feature with unusual radiological findings made these

  19. Validation of exposure visualization and audible distance emission for navigated temporal bone drilling in phantoms.

    Directory of Open Access Journals (Sweden)

    Eduard H J Voormolen

    Full Text Available BACKGROUND: A neuronavigation interface with extended function as compared with current systems was developed to aid during temporal bone surgery. The interface, named EVADE, updates the prior anatomical image and visualizes the bone drilling process virtually in real-time without need for intra-operative imaging. Furthermore, EVADE continuously calculates the distance from the drill tip to segmented temporal bone critical structures (e.g. the sigmoid sinus and facial nerve and produces audiovisual warnings if the surgeon drills in too close vicinity. The aim of this study was to evaluate the accuracy and surgical utility of EVADE in physical phantoms. METHODOLOGY/PRINCIPAL FINDINGS: We performed 228 measurements assessing the position accuracy of tracking a navigated drill in the operating theatre. A mean target registration error of 1.33±0.61 mm with a maximum error of 3.04 mm was found. Five neurosurgeons each drilled two temporal bone phantoms, once using EVADE, and once using a standard neuronavigation interface. While using standard neuronavigation the surgeons damaged three modeled temporal bone critical structures. No structure was hit by surgeons utilizing EVADE. Surgeons felt better orientated and thought they had improved tumor exposure with EVADE. Furthermore, we compared the distances between surface meshes of the virtual drill cavities created by EVADE to actual drill cavities: average maximum errors of 2.54±0.49 mm and -2.70±0.48 mm were found. CONCLUSIONS/SIGNIFICANCE: These results demonstrate that EVADE gives accurate feedback which reduces risks of harming modeled critical structures compared to a standard neuronavigation interface during temporal bone phantom drilling.

  20. Assessment of bone marrow inflammation in patients with myelofibrosis: an {sup 18}F-fluorodeoxyglucose PET/CT study

    Energy Technology Data Exchange (ETDEWEB)

    Derlin, Thorsten [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Alchalby, Haefaa; Triviai, Ioanna; Kroeger, Nicolaus [University Medical Center Hamburg-Eppendorf, Clinic for Stem Cell Transplantation, Hamburg (Germany); Bannas, Peter [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Veldhoen, Simon [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Wuerzburg (Germany); Apostolova, Ivayla [Otto-von-Guericke University, Department of Radiology and Nuclear Medicine, Magdeburg (Germany); Bengel, Frank M. [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany)

    2015-04-01

    Myelofibrosis is a haematopoietic stem cell neoplasm characterized by bone marrow inflammation, reactive marrow fibrosis and extramedullary haematopoiesis. The aim of this study was to determine if {sup 18}F-FDG PET/CT can be used to noninvasively visualize and quantify the extent and activity of bone marrow involvement. In 30 patients, the biodistribution of {sup 18}F-FDG was analysed by measuring the standardized uptake value in the bone marrow compartment and spleen. Imaging findings were compared with laboratory, cytogenetic and histopathological data. Retention of {sup 18}F-FDG was observed in bone marrow and spleen. Bone marrow involvement varied, ranging from mildly increased uptake in the central skeleton to extensive uptake in most parts of the skeleton. The extent of bone marrow involvement decreased over time from initial diagnosis (r{sub s} = -0.43, p = 0.019). Metabolic activity of the bone marrow decreased as the histopathological grade of fibrosis increased (r{sub s} = -0.37, p = 0.04). There was a significant positive correlation between the metabolic activity of the bone marrow and that of the spleen (p = 0.04). {sup 18}F-FDG PET/CT is as a promising technique for the quantitation of bone marrow inflammation in myelofibrosis. Our data indicate that the intensity of bone marrow {sup 18}F-FDG uptake decreases as bone marrow fibrosis increases. Further evaluation in prospective studies is required to determine the potential clinical impact and prognostic significance of PET. (orig.)

  1. Classification of micro-CT images using 3D characterization of bone canal patterns in human osteogenesis imperfecta

    Science.gov (United States)

    Abidin, Anas Z.; Jameson, John; Molthen, Robert; Wismüller, Axel

    2017-03-01

    Few studies have analyzed the microstructural properties of bone in cases of Osteogenenis Imperfecta (OI), or `brittle bone disease'. Current approaches mainly focus on bone mineral density measurements as an indirect indicator of bone strength and quality. It has been shown that bone strength would depend not only on composition but also structural organization. This study aims to characterize 3D structure of the cortical bone in high-resolution micro CT images. A total of 40 bone fragments from 28 subjects (13 with OI and 15 healthy controls) were imaged using micro tomography using a synchrotron light source (SRµCT). Minkowski functionals - volume, surface, curvature, and Euler characteristics - describing the topological organization of the bone were computed from the images. The features were used in a machine learning task to classify between healthy and OI bone. The best classification performance (mean AUC - 0.96) was achieved with a combined 4-dimensional feature of all Minkowski functionals. Individually, the best feature performance was seen using curvature (mean AUC - 0.85), which characterizes the edges within a binary object. These results show that quantitative analysis of cortical bone microstructure, in a computer-aided diagnostics framework, can be used to distinguish between healthy and OI bone with high accuracy.

  2. Rheumatoid arthritis bone erosion volumes on CT and MRI: reliability and correlations with erosion scores on CT, MRI and radiography

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Ejbjerg, Bo J; Hasselquist, Maria;

    2007-01-01

    controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). RESULTS: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean...

  3. CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dong; Brace, Christopher L., E-mail: clbrace@wisc.edu [Departments of Radiology and Biomedical Engineering, University of Wisconsin, Madison, Wisconsin 53705 (United States)

    2014-11-01

    Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

  4. Computer tomography in children and adolescents with suspected malformation of the petrous portion of the temporal bone; Computertomographie bei Kindern und Jugendlichen mit Verdacht auf eine Felsenbeinmissbildung

    Energy Technology Data Exchange (ETDEWEB)

    Koesling, S.; Schneider-Moebius, C. [Klinik und Poliklinik fuer Diagnostische Radiologie, Univ. Leipzig (Germany); Koenig, E.; Meister, E.F. [Klinik und Poliklinik fuer Hals-Nasen-Ohrenkrankheiten, Univ. Leipzig (Germany)

    1997-12-01

    Purpose: To demonstrate HRCT findings and their therapeutic relevance in suspected congenital hearing disorders. Material and Methods: It was checked in 96 young patients if HRCT findings of the temporal bone could explain functional findings. Furthermore, the therapeutic consequences were noted. Results: Normal CT and normal functional findings were obtained in 49 temporal bones (TB). In conductive hearing loss (41 TB), dysplasias of the conducting apparatus (37 TB) and inflammatory changes (3 TB) were found. Combined hearing loss (18 TB) was clarified completely or partially in half the cases. There were 22 dysplasias of the inner ear, 3 dysplasias of the middle ear, 1 adandoned examination (2 TB), and 55 normal CT findings in senorineural hearing disorders (82 TB). 1 retardate had a malformation of the inner ear and, contralaterally, inflammatory middle ear. In cases of vestibular disorders (24 TB), 14 malformations of the inner ear were detected. (orig./AJ) [Deutsch] Ziel der Untersuchung war die Darstellung von HR-CT-Befunden und ihrer therapeutischen Relevanz bei Verdacht auf angeborene Hoerstoerungen. An 96 jungen Patienten wurde ueberprueft, inwieweit die Felsenbein-HRT-CT-Befunde mit Ergebnissen funktioneller Tests uebereinstimmten und welche therapeutischen Konsequenzen sich ergaben. Normale Funktions- und CT-Befunde zeigten 49 Felsenbeine (FB). Bei Schalleitungsschwerhoerigkeit (41 FB) wurden Missbildungen des Schalleitungsapparates (37 FB) bzw. entzuendliche Veraenderungen (3 FB) gefunden. Kombinierte Schwerhoerigkeiten (18 FB) konnten zur Haelfte teilweise oder vollstaendig abgeklaert werden. Bei sensorineuralen Hoerstoerungen (82 FB) fanden sich 22 Innenohrmissbildungen, 3 Mittelohrmissbildungen, 55 Normalbefunde, ein Untersuchungsabbruch (2 FB). 1 Debiler wies eine Innenohrmissbildung, kontralateral entzuendliche Mittelohrveraenderungen auf. (orig./AJ)

  5. Quantitative analysis of Neanderthal temporal bone morphology using three-dimensional geometric morphometrics.

    Science.gov (United States)

    Harvati, Katerina

    2003-04-01

    The temporal bone is the location of several traits thought to differentiate Neanderthals from modern humans, including some proposed Neanderthal-derived traits. Most of these, however, are difficult to measure and are usually described qualitatively. This study applied the techniques of geometric morphometrics to the complex morphology of the temporal bone, in order to quantify the differences observed between Neanderthal and modern human anatomy. Two hundred and seventy modern human crania were measured, representing 9 populations of 30 individuals each, and spanning the extremes of the modern human geographical range. Twelve Neanderthal specimens, as well as Reilingen, Kabwe, Skhul 5, Qafzeh 9, and 4 Late Paleolithic European specimens, were included in the fossil sample. The data were collected in the form of three-dimensional (3-D) landmark coordinates, and specimen configurations were superimposed using generalized Procrustes analysis. The fitted coordinates were then analyzed by an array of multivariate statistical methods, including principal components analysis, canonical variates analysis, and Mahalanobis D(2). The temporal bone landmark analysis was very successful in separating Neanderthals from modern humans. Neanderthals were separated from modern humans in both the principal components and canonical variates analyses. They were much further in Mahalanobis distances from all modern human populations than any two modern human groups were from each other. Most of the previously described temporal bone traits contributed to this separation. Copyright 2003 Wiley-Liss, Inc.

  6. Pneumatization of the Temporal Bones in a Greenlandic Inuit Anthropological Material

    DEFF Research Database (Denmark)

    Homøe, P; Lynnerup, N

    1991-01-01

    The degree of pneumatization of the temporal bones correlates with exposure during childhood and adolescence to infectious middle ear diseases (IMED), both acute and chronic. The pneumatized area as seen on cranial X-rays can be measured. This was applied to an anthropological material in order...

  7. Factors Associated with No or Insufficient Temporal Bone Window Using Transcranial Color-coded Sonography

    Directory of Open Access Journals (Sweden)

    Yi-Pin Lin

    2015-09-01

    Conclusion: The failure rate of temporal bone window was considered high as compared to Western countries but, not surprisingly, age and sex remained the significant factors. Introducing echo contrast agents during the TCCS examination might help to increase the success rate of TCCS examination and provide useful information to clinicians.

  8. Assessment of the increased calcification of the jaw bone with CT-Scan after dental implant placement

    Energy Technology Data Exchange (ETDEWEB)

    Yunus, Barunawaty [Faculty of Dentistry, Hasanuddin University, Makassar (Malaysia)

    2011-06-15

    This study was performed to evaluate the changes of jaw bone density around the dental implant after placement using computed tomography scan (CT-Scan). This retrospective study consisted of 30 patients who had lost 1 posterior tooth in maxilla or mandible and installed dental implant. The patients took CT-Scan before and after implant placement. Hounsfield Unit (HU) was measured around the implants and evaluated the difference of HU before and after implant installation. The mean HU of jaw bone was 542.436 HU and 764.9 HU before and after implant placement, respectively (p<0.05). The means HUs for male were 632.3 HU and 932.2 HU and those for female 478.2 HU and 645.5 HU before and after implant placement, respectively (p<0.05). Also, the jaw bone with lower density needed longer period for implant procedure and the increased change of HU of jaw bone was less in the cases which needed longer period for osseointegration. CT-Scan could be used to assess the change of bone density around dental implants. Bone density around dental implant was increased after placement. The increased rate of bone density could be determined by the quality of jaw bone before implant placement.

  9. Wavelet based characterization of ex vivo vertebral trabecular bone structure with 3T MRI compared to microCT

    Energy Technology Data Exchange (ETDEWEB)

    Krug, R; Carballido-Gamio, J; Burghardt, A; Haase, S; Sedat, J W; Moss, W C; Majumdar, S

    2005-04-11

    Trabecular bone structure and bone density contribute to the strength of bone and are important in the study of osteoporosis. Wavelets are a powerful tool to characterize and quantify texture in an image. In this study the thickness of trabecular bone was analyzed in 8 cylindrical cores of the vertebral spine. Images were obtained from 3 Tesla (T) magnetic resonance imaging (MRI) and micro-computed tomography ({micro}CT). Results from the wavelet based analysis of trabecular bone were compared with standard two-dimensional structural parameters (analogous to bone histomorphometry) obtained using mean intercept length (MR images) and direct 3D distance transformation methods ({micro}CT images). Additionally, the bone volume fraction was determined from MR images. We conclude that the wavelet based analyses delivers comparable results to the established MR histomorphometric measurements. The average deviation in trabecular thickness was less than one pixel size between the wavelet and the standard approach for both MR and {micro}CT analysis. Since the wavelet based method is less sensitive to image noise, we see an advantage of wavelet analysis of trabecular bone for MR imaging when going to higher resolution.

  10. 18F-FDG PET/CT for Early Postradiotherapy Assessment in Solitary Bone Plasmacytomas.

    Science.gov (United States)

    Alongi, Pierpaolo; Zanoni, Lucia; Incerti, Elena; Fallanca, Federico; Mapelli, Paola; Papathanasiou, Nikolaos; Gianolli, Luigi; Picchio, Maria; Bomanji, Jamshed

    2015-08-01

    The purpose of this study was to evaluate the performance and possible prognostic value of early (18)F-FDG PET/CT (FDG PET/CT) assessment after radiotherapy (RT) in patients with solitary bone plasmacytoma (SBP). Twenty-one patients affected by SBP who underwent FDG PET/CT scan for early restaging (≤6 months) postradiotherapy assessment were selected from the PET databases of University College London Hospital of London and San Raffaele Hospital of Milan. Patients with no abnormal uptake were classified as having no pathologic uptake (NPU). A SUV(max) cutoff value of 4 was chosen to discriminate minimal residual uptake (MRU; SUV(max) ≤ 4) from pathologic uptake (PU, SUV(max) >4). Progression-free survival (PFS) rate was estimated using Kaplan-Meier curves and Cox regression analysis. In 10 of 21 patients restaged by FDG PET/CT, further previous baseline scan was available also at staging, and results showed positive findings at the level of all biopsy-proven disease areas.Considering MRU as PU, FDG PET/CT showed a sensitivity and specificity of 86% and 29%, respectively. Using SUV(max) >4 as the cutoff, sensitivity and specificity were 86% and 93%, respectively. Kaplan-Meier curves revealed a significant difference in PFS probability between patients classified as positive on FDG PET/CT using a cutoff of SUV(max) >4 (PU) and those classified as negative (NPU + MRU) (log-rank, Mantel-Cox, P = 0.009; χ(2) = 6.85). Cox regression analysis of PFS using SUV(max) >4 as cutoff revealed an interesting relation in prediction of progression (HR, 9.458). (18)F-FDG PET/CT for early restaging after RT in patients with SBP should be considered carefully in view of the lack of specificity of a low SUV(max) value. The good correlation between a high SUV(max) value and follow-up suggests a possible prognostic role for FDG PET/CT in disease progression at early restaging after RT.

  11. Diagnostic performance of (11)C-choline PET/CT and bone scintigraphy in the detection of bone metastases in patients with prostate cancer.

    Science.gov (United States)

    Kitajima, Kazuhiro; Fukushima, Kazuhito; Yamamoto, Shingo; Kato, Takashi; Odawara, Soichi; Takaki, Haruyuki; Fujiwara, Masayuki; Yamakado, Koichiro; Nakanishi, Yukako; Kanematsu, Akihiro; Nojima, Michio; Hirota, Shozo

    2017-08-01

    The aim of this study was to compare 11C-choline PET/CT and bone scintigraphy (BS) for detection of bone metastases in patients with prostate cancer. Twenty-one patients with histologically proven prostate cancer underwent 11C-choline PET/CT and BS before (n = 4) or after (n = 17) treatment. Patient-, region-, and lesion-based diagnostic performances of bone metastasis of both 11C-choline PET/CT and BS were evaluated using a five-point scale by two experienced readers. Bone metastases were present in 11 (52.4%) of 21 patients and 48 (32.7%) of 147 regions; 111 lesions were found to have bone metastases. Region-based analysis showed that the sensitivity, specificity, accuracy, and area under the receiver-operating-characteristic curves (AUC) of 11C-choline PET/CT were 97.9%, 99.0%, 98.6%, and 0.9989, respectively; those of BS were 72.9%, 99.0%, 90.5%, and 0.8386, respectively. Sensitivity, accuracy, and AUC significantly differed between the two methods (McNemar test, p = 0.0015, p = 0.0015, and p PET/CT detected 110/111 metastatic lesions (99.1%); BS detected 85 (76.6%) (p PET/BS were 100%/90.3% for the blastic type, 91.7%/8.3% for the lytic type, 100%/100% for the mixed type, and 100%/53.3% for the invisible type, respectively. Significant differences in blastic, lytic, and invisible types were observed between the two methods (p = 0.013, p = 0.0044, and p = 0.023, respectively). In conclusion, 11C-choline PET/CT had greater sensitivity and accuracy than BS for detection of bone involvement in patients with prostate cancer.

  12. MicroCT Bone Densitometry: Context Sensitivity, Beam Hardening Correction and the Effect of Surrounding Media

    Directory of Open Access Journals (Sweden)

    Philip L. Salmon

    2014-12-01

    Full Text Available The context-sensitivity of microCT bone densitometry due to beam hardening artefacts was assessed. Bones and teeth are scanned with varying thickness of surrounding media (water, alcohol, biological tissue and it is important to understand how this affects reconstructed attenuation (“density” of the mineralized tissue. Aluminium tubes and rods with thickness 0.127mm–5mm were scanned both in air or surrounded by up to 2cm of water. Scans were performed with different energy filters and degrees of software beam hardening correction (BHC. Also tested were the effects of signal-to-noise ratio, magnification and truncation. The thickness of an aluminium tube significantly affected its mean reconstructed attenuation. This effect of thickness could be reduced substantially by BHC for scans in air, but not for scans in water. Varying thickness of surrounding water also changed the mean attenuation of an aluminium tube. This artefact could be almost eliminated by an optimal BHC value. The “cupping” artefact of heterogeneous attenuation (elevated at outer surfaces could be corrected if aluminium was scanned in air, but in water BHC was much less effective. Scan truncation, changes to magnification and signal-to-noise ratio also caused artificial changes to measured attenuation. Measurement of bone mineral density by microCT is highly context sensitive. A surrounding layer of liquid or biological tissue reduces the ability of software BHC to remove bone density artefacts. Sample thickness, truncation, magnification and signal to noise ratio also affect reconstructed attenuation. Thus it is important for densitometry that sample and calibration phantom dimensions and mounting materials are standardised.

  13. Technique for bone volume measurement from human femur head samples by classification of micro-CT image histograms

    Directory of Open Access Journals (Sweden)

    Franco Marinozzi

    2013-09-01

    Full Text Available INTRODUCTION: Micro-CT analysis is a powerful technique for a non-invasive evaluation of the morphometric parameters of trabecular bone samples. This elaboration requires a previous binarization of the images. A problem which arises from the binarization process is the partial volume artifact. Voxels at the external surface of the sample can contain both bone and air so thresholding operates an incorrect estimation of volume occupied by the two materials. AIM: The aim of this study is the extraction of bone volumetric information directly from the image histograms, by fitting them with a suitable set of functions. METHODS: Nineteen trabecular bone samples were extracted from femoral heads of eight patients subject to a hip arthroplasty surgery. Trabecular bone samples were acquired using micro-CT Scanner. Hystograms of the acquired images were computed and fitted by Gaussian-like functions accounting for: a gray levels produced by the bone x-ray absorption, b the portions of the image occupied by air and c voxels that contain a mixture of bone and air. This latter contribution can be considered such as an estimation of the partial volume effect. RESULTS: The comparison of the proposed technique to the bone volumes measured by a reference instrument such as by a helium pycnometer show the method as a good way for an accurate bone volume calculation of trabecular bone samples.

  14. {sup 18}F-FDG PET/CT compared to conventional imaging modalities in pediatric primary bone tumors

    Energy Technology Data Exchange (ETDEWEB)

    London, Kevin [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Paediatrics and Child Health, Sydney Medical School, Sydney, NSW (Australia); Stege, Claudia; Kaspers, Gertjan [VU Medical Centre, Divisions of Paediatric Oncology/Haematology, Amsterdam (Netherlands); Cross, Siobhan; Dalla-Pozza, Luciano [The Children' s Hospital at Westmead, Department of Oncology, Sydney (Australia); Onikul, Ella [The Children' s Hospital at Westmead, Department of Medical Imaging, Sydney (Australia); Graf, Nicole [The Children' s Hospital at Westmead, Department of Pathology, Sydney (Australia); Howman-Giles, Robert [The Children' s Hospital at Westmead, Department of Nuclear Medicine, Sydney, NSW (Australia); University of Sydney, Discipline of Imaging, Sydney Medical School, Sydney, NSW (Australia)

    2012-04-15

    F-Fluoro-2-deoxy-d-glucose (FDG) positron emission tomography (PET) is useful in adults with primary bone tumors. Limited published data exist in children. To compare hybrid FDG positron emission tomography/computed tomography (PET/CT) with conventional imaging (CI) modalities in detecting malignant lesions, predicting response to chemotherapy and diagnosing physeal involvement in pediatric primary bone tumors. Retrospective analysis of PET/CT and CI reports with histopathology or follow-up > 6 months as reference standard. Response parameters and physeal involvement at diagnosis were compared to histopathology. A total of 314 lesions were detected in 86 scans. Excluding lung lesions, PET/CT had higher sensitivity and specificity than CI (83%, 98% and 78%, 97%, respectively). In lung lesions, PET/CT had higher specificity than CI (96% compared to 87%) but lower sensitivity (80% compared to 93%). Higher initial SUV{sub max} and greater SUV{sub max} reduction on PET/CT after chemotherapy predicted a good response. Change in tumor size on MRI did not predict response. Both PET/CT and MRI were very sensitive but of low specificity in predicting physeal tumor involvement. PET/CT appears more accurate than CI in detecting malignant lesions in childhood primary bone tumors, excluding lung lesions. It seems better than MRI at predicting tumor response to chemotherapy. (orig.)

  15. Successful Function-Preserving Therapy for Chondroblastoma of the Temporal Bone Involving the Temporomandibular Joint

    Directory of Open Access Journals (Sweden)

    Junkichi Yokoyama

    2011-02-01

    Full Text Available We present a case involving a late diagnosis of chondroblastoma of the temporal skull base involving the temporomandibular joint (TMJ. Following an initial misdiagnosis and unsuccessful treatment over a period of 5 years, the patient was referred to our department for further evaluation and possible surgical intervention for occlusal abnormalities, trismus, clicking of the TMJ, and hearing impairment. Based on preoperative immunochemical studies showing positive reaction of multinucleated giant cells for S-100 protein, the final diagnosis was chondroblastoma. The surgical approach – postauricular incision and total parotidectomy, with complete removal of the temporal bone, including the TMJ via the extended middle fossa – was successful in preserving facial nerves and diminishing clinical manifestations. This study highlights a misdiagnosed case in an effort to underline the importance of medical examinations and accurate differential diagnosis in cases involving any tumor mass in the temporal bone.

  16. Successful function-preserving therapy for chondroblastoma of the temporal bone involving the temporomandibular joint.

    Science.gov (United States)

    Yokoyama, Junkichi; Yoshimoto, Hitoshi; Ito, Shin; Ohba, Shinichi; Fujimaki, Mitsuhisa; Ikeda, Katsuhisa; Yazawa, Masaki; Fujimiya, Nozomi; Hanaguri, Makoto

    2011-02-14

    We present a case involving a late diagnosis of chondroblastoma of the temporal skull base involving the temporomandibular joint (TMJ). Following an initial misdiagnosis and unsuccessful treatment over a period of 5 years, the patient was referred to our department for further evaluation and possible surgical intervention for occlusal abnormalities, trismus, clicking of the TMJ, and hearing impairment. Based on preoperative immunochemical studies showing positive reaction of multinucleated giant cells for S-100 protein, the final diagnosis was chondroblastoma. The surgical approach - postauricular incision and total parotidectomy, with complete removal of the temporal bone, including the TMJ via the extended middle fossa - was successful in preserving facial nerves and diminishing clinical manifestations. This study highlights a misdiagnosed case in an effort to underline the importance of medical examinations and accurate differential diagnosis in cases involving any tumor mass in the temporal bone.

  17. Unbiased Stereologic Estimation of the Spatial Distribution of Paget’s Disease in the Human Temporal Bone

    DEFF Research Database (Denmark)

    Bloch, Sune Land; Sørensen, Mads Sølvsten

    2014-01-01

    BACKGROUND: It has been suggested that Paget's disease of bone and otosclerosis may share a myxoviral etiology. However, the association between virus infection and pathologic bone remodeling is still controversial. The aim of this study was to estimate the spatial distribution of pagetic bone...... remodeling around the inner ear space and to compare it with that of otosclerosis in a contemporary context of temporal bone dynamics. MATERIALS AND METHODS: From the temporal bone collection of Massachusetts Eye and Ear Infirmary, 15 of 29 temporal bones with Paget's disease were selected to obtain...... is similar to the normal distribution of perilabyrinthine bone remodeling but entirely different from the spatial location of otosclerosis, which are focal and centripetally distributed around the inner ear space. CONCLUSION: In Paget's disease, the antiresorptive barrier around the inner ear space becomes...

  18. Scaling relations between bone volume and bone structure as found using 3D µCT images of the trabecular bone taken from different skeletal sites

    Science.gov (United States)

    Raeth, Christoph; Müller, Dirk; Sidorenko, Irina; Monetti, Roberto; Eckstein, Felix; Matsuura, Maiko; Lochmüller, Eva-Maria; Zysset, Philippe K.; Bauer, Jan

    2010-03-01

    According to Wolff's law bone remodels in response to the mechanical stresses it experiences so as to produce a minimal-weight structure that is adapted to its applied stresses. Here, we investigate the relations between bone volume and structure for the trabecular bone using 3D μCT images taken from different skeletal sites in vitro, namely from the distal radii (96 specimens), thoracic (73 specimens) and lumbar vertebrae (78 specimens). We determine the local structure of the trabecular network by calculating isotropic and anisotropic scaling indices (α, αz). These measures have been proven to be able to discriminate rod- from sheet-like structures and to quantify the alignment of structures with respect to a preferential direction as given by the direction of the external force. Comparing global structure measures derived from the scaling indices (mean, standard deviation) with the bone mass (BV/TV) we find that all correlations obey very accurately power laws with scaling exponents of 0.14, 0.12, 0.15 (~), -0.2, -017, -0.17 (σ(αz)), 0.09, 0.05, 0.07 (~) and -0.20, -0.11 ,-0.13 (σ(αz)) distal radius, thoracic vertebra and lumbar vertebra respectively. Thus, these relations turn out to be site-independent, albeit the mechanical stresses to which the bones of the forearm and the spine are exposed, are quite different. The similar alignment might not be in agreement with a universal validity of Wolff's law. On the other hand, such universal power law relations may allow to develop additional diagnostic means to better assess healthy and osteoporotic bone.

  19. Comparison of choline-PET/CT, MRI, SPECT, and bone scintigraphy in the diagnosis of bone metastases in patients with prostate cancer: a meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Guohua; Deng, Houfu; Hu, Shuang; Jia, Zhiyun [West China Hospital of Sichuan University, Department of Nuclear Medicine, Chengdu, Sichuan (China)

    2014-11-15

    Published data on the diagnosis of bone metastases of prostate cancer are conflicting and heterogeneous. We performed a comprehensive meta-analysis to compare the diagnostic performance of choline-PET/CT, MRI, bone SPECT, and bone scintigraphy (BS) in detecting bone metastases in parents with prostate cancer. Pooled sensitivity, specificity, and diagnostic odds ratios (DOR) were calculated both on a per-patient basis and on a per-lesion basis. Summary receiver operating characteristic (SROC) curves were also drawn to obtain the area under curve (AUC) and Q* value. Sixteen articles consisting of 27 studies were included in the analysis. On a per-patient basis, the pooled sensitivities by using choline PET/CT, MRI, and BS were 0.91 [95 % confidence interval (CI): 0.83-0.96], 0.97 (95 % CI: 0.91-0.99), 0.79 (95 % CI: 0.73-0.83), respectively. The pooled specificities for detection of bone metastases using choline PET/CT, MRI, and BS, were 0.99 (95 % CI: 0.93-1.00), 0.95 (95 % CI: 0.90-0.97), and 0.82 (95 % CI: 0.78-0.85), respectively. On a per-lesion basis, the pooled sensitivities of choline PET/CT, bone SPECT, and BS were 0.84 (95 % CI: 0.81-0.87), 0.90 (95 % CI: 0.86-0.93), 0.59 (95 % CI: 0.55-0.63), respectively. The pooled specificities were 0.93 (95 % CI: 0.89-0.96) for choline PET/CT, 0.85 (95 % CI: 0.80-0.90) for bone SPECT, and 0.75 (95 % CI: 0.71-0.79) for BS. This meta-analysis indicated that MRI was better than choline PET/CT and BS on a per-patient basis. On a per-lesion analysis, choline PET/CT with the highest DOR and Q* was better than bone SPECT and BS for detecting bone metastases from prostate cancer. (orig.)

  20. Coronary artery visibility in free-breathing young children on non-gated chest CT: impact of temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Bridoux, Alexandre; Hutt, Antoine; Faivre, Jean-Baptiste; Pagniez, Julien; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), 59037 Lille Cedex (France); Flohr, Thomas [Siemens Healthcare, Department of Research and Development in CT, Forchheim (Germany); Duhamel, Alain [Universite de Lille, Department of Biostatistics, Lille (France)

    2015-11-15

    Dual-source CT allows scanning of the chest with high pitch and high temporal resolution, which can improve the detection of proximal coronary arteries in infants and young children when scanned without general anesthesia, sedation or beta-blockade. To compare coronary artery visibility between higher and standard temporal resolution. We analyzed CT images in 93 children who underwent a standard chest CT angiographic examination with reconstruction of images with a temporal resolution of 75 ms (group 1) and 140 ms (group 2). The percentage of detected coronary segments was higher in group 1 than in group 2 when considering all segments (group 1: 27%; group 2: 24%; P = 0.0004) and proximal segments (group 1: 37%; group 2: 32%; P = 0.0006). In both groups, the highest rates of detection were observed for the left main coronary artery (S1) (group 1: 65%; group 2: 58%) and proximal left anterior descending coronary artery (S2) (group 1: 43%; group 2: 42%). Higher rates of detection were seen in group 1 for the left main coronary artery (P = 0.03), proximal right coronary artery (P = 0.01), proximal segments of the left coronary artery (P = 0.02) and proximal segments of the left and right coronary arteries (P = 0.0006). Higher temporal resolution improved the visibility of proximal coronary arteries in pediatric chest CT. (orig.)

  1. Repeatability of quantitative parameters of 18F-fluoride PET/CT and biochemical tumour and specific bone remodelling markers in prostate cancer bone metastases.

    Science.gov (United States)

    Wassberg, Cecilia; Lubberink, Mark; Sörensen, Jens; Johansson, Silvia

    2017-12-01

    18F-fluoride PET/CT exhibits high sensitivity to delineate and measure the extent of bone metastatic disease in patients with prostate cancer. 18F-fluoride PET/CT could potentially replace traditional bone scintigraphy in clinical routine and trials. However, more studies are needed to assess repeatability and biological uptake variation. The aim of this study was to perform test-retest analysis of quantitative PET-derived parameters and blood/serum bone turnover markers at the same time point. Ten patients with prostate cancer and verified bone metastases were prospectively included. All underwent two serial 18F-fluoride PET/CT at 1 h post-injection. Up to five dominant index lesions and whole-body 18F-fluoride skeletal tumour burden were recorded per patient. Lesion-based PET parameters were SUVmax, SUVmean and functional tumour volume applying a VOI with 50% threshold (FTV50%). The total skeletal tumour burden, total lesion 18F-fluoride (TLF), was calculated using a threshold of SUV of ≥15. Blood/serum biochemical bone turnover markers obtained at the time of each PET were PSA, ALP, S-osteocalcin, S-beta-CTx, 1CTP and BAP. A total of 47 index lesions and a range of 2-122 bone metastases per patient were evaluated. Median time between 18F-fluoride PET/CT was 7 days (range 6-8 days). Repeatability coefficients were for SUVmax 26%, SUVmean 24%, FTV50% for index lesions 23% and total skeletal tumour burden (TLF) 35%. Biochemical bone marker repeatability coefficients were for PSA 19%, ALP 23%, S-osteocalcin 18%, S-beta-CTx 22%, 1CTP 18% and BAP 23%. Quantitative 18F-fluoride uptake and simultaneous biochemical bone markers measurements are reproducible for prostate cancer metastases and show similar magnitude in test-retest variation.

  2. A new Level-set based Protocol for Accurate Bone Segmentation from CT Imaging

    CERN Document Server

    Pinheiro, Manuel

    2015-01-01

    In this work it is proposed a medical image segmentation pipeline for accurate bone segmentation from CT imaging. It is a two-step methodology, with a pre-segmentation step and a segmentation refinement step. First, the user performs a rough segmenting of the desired region of interest. Next, a fully automatic refinement step is applied to the pre-segmented data. The automatic segmentation refinement is composed by several sub-stpng, namely image deconvolution, image cropping and interpolation. The user-defined pre-segmentation is then refined over the deconvolved, cropped, and up-sampled version of the image. The algorithm is applied in the segmentation of CT images of a composite femur bone, reconstructed with different reconstruction protocols. Segmentation outcomes are validated against a gold standard model obtained with coordinate measuring machine Nikon Metris LK V20 with a digital line scanner LC60-D that guarantees an accuracy of 28 $\\mu m$. High sub-pixel accuracy models were obtained for all tested...

  3. Immediate periodontal bone plate changes induced by rapid maxillary expansion in the early mixed dentition: CT findings

    Directory of Open Access Journals (Sweden)

    Daniela Gamba Garib

    2014-06-01

    Full Text Available OBJECTIVE: This study aimed at evaluating buccal and lingual bone plate changes caused by rapid maxillary expansion (RME in the mixed dentition by means of computed tomography (CT. METHODS: The sample comprised spiral CT exams taken from 22 mixed dentition patients from 6 to 9 years of age (mean age of 8.1 years presenting constricted maxillary arch treated with Haas-type expanders. Patients were submitted to spiral CT scan before expansion and after the screw activation period with a 30-day interval between T1 and T2. Multiplanar reconstruction was used to measure buccal and lingual bone plate thickness and buccal bone crest level of maxillary posterior deciduous and permanent teeth. Changes induced by expansion were evaluated using paired t test (p < 0.05. RESULTS: Thickness of buccal and lingual bone plates of posterior teeth remained unchanged during the expansion period, except for deciduous second molars which showed a slight reduction in bone thickness at the distal region of its buccal aspect. Buccal bone dehiscences were not observed in the supporting teeth after expansion. CONCLUSION: RME performed in mixed dentition did not produce immediate undesirable effects on periodontal bone tissues.

  4. Use of CT densitometry to predict lung toxicity in bone marrow transplant patients

    Energy Technology Data Exchange (ETDEWEB)

    el-Khatib, E.E.; Freeman, C.R.; Rybka, W.B.; Lehnert, S.; Podgorsak, E.B.

    1989-01-01

    Total body irradiation (TBI) is considered an integral part of the preparation of patients with hematological malignancies for marrow transplantation. One of the major causes of death following bone marrow transplantation is interstitial pneumonia. Its pathogenesis is complex but radiation may play a major role in its development. Computed tomography (CT) has been used in animal and human studies as a sensitive non-invasive method for detecting changes in the lung following radiotherapy. In the present study CT scans are studied before and up to 1 year after TBI. Average lung densities measured before TBI showed large variations among the individual patients. On follow-up scans, lung density decreases were measured for patients who did not develop lung complications. Significant lung density increases were measured in patients who subsequently had lung complications. These lung density increases were observed prior to the onset of respiratory complications and could be correlated with the clinical course of the patients, suggesting the possibility for the usage of CT lung densitometry to predict lung complications before the onset of clinical symptoms.

  5. Large capillary hemangioma of the temporal bone with a dural tail sign: A case report

    KAUST Repository

    YANG, GUANG

    2014-05-13

    The present study reports a rare case of large capillary hemangioma of the temporal bone with a dural tail sign. A 57-year-old female presented with pulsatile tinnitus and episodic vertigo associated with a ten-year history of an intermittent faint headache. Magnetic resonance imaging revealed a mass in the right petrous bone, which was hypointense on T1-weighted images and heterogeneously hyperintense on T2-weighted images, and showed a dural tail sign following gadolinium administration. Pre-operatively, this tumor was believed to be a meningioma. During surgery, the vascular tumor was removed by a modified pterional approach. A histopathological examination indicated that the tumor was a capillary hemangioma. Although intraosseous capillary hemangiomas are rare, they most frequently affect the temporal bone. Hemangiomas of the temporal bone may mimic other more common basal tumors. The diagnosis is most often made during surgical resection. The dural tail sign is not specific for meningioma, as it also occurs in other intracranial or extracranial tumors. The treatment of intratemporal hemangiomas is complete surgical excision, with radiotherapy used for unresectable lesions. To the best of our knowledge, the present study is the fourth case of intraosseous intracranial capillary hemangioma, but the largest intratemporal hemangioma to be reported in the literature to date.

  6. Large capillary hemangioma of the temporal bone with a dural tail sign: A case report.

    Science.gov (United States)

    Yang, Guang; Li, Chenguang; Chen, Xin; Liu, Yaohua; Han, Dayong; Gao, Xin; Kawamoto, Keiji; Zhao, Shiguang

    2014-07-01

    The present study reports a rare case of large capillary hemangioma of the temporal bone with a dural tail sign. A 57-year-old female presented with pulsatile tinnitus and episodic vertigo associated with a ten-year history of an intermittent faint headache. Magnetic resonance imaging revealed a mass in the right petrous bone, which was hypointense on T1-weighted images and heterogeneously hyperintense on T2-weighted images, and showed a dural tail sign following gadolinium administration. Pre-operatively, this tumor was believed to be a meningioma. During surgery, the vascular tumor was removed by a modified pterional approach. A histopathological examination indicated that the tumor was a capillary hemangioma. Although intraosseous capillary hemangiomas are rare, they most frequently affect the temporal bone. Hemangiomas of the temporal bone may mimic other more common basal tumors. The diagnosis is most often made during surgical resection. The dural tail sign is not specific for meningioma, as it also occurs in other intracranial or extracranial tumors. The treatment of intratemporal hemangiomas is complete surgical excision, with radiotherapy used for unresectable lesions. To the best of our knowledge, the present study is the fourth case of intraosseous intracranial capillary hemangioma, but the largest intratemporal hemangioma to be reported in the literature to date.

  7. Gaucher's disease. Plain radiography, US, CT and MR diagnosis of lungs, bone and liver lesions

    Energy Technology Data Exchange (ETDEWEB)

    Hainaux, B.; Christophe, C.; Hanquinet, S.; Perlmutter, N. (Free Univ. of Brussels (Belgium). Dept. of Pediatric Radiology)

    1992-04-01

    We report our observations made by conventional radiography, ultrasound, computerized tomography (CT), and magnetic resonance imaging (MRI) on a 3 1/2-year-old girl with Gaucher's disease. The interest of the case consists in the exceptional lungs involvement, the demonstration by MRI of the bone marrow involvement and the necrosis and fibrosis of the liver, as shown by CT. This liver complication has been previously reported only once. (orig.).

  8. Independent measurement of femoral cortical thickness and cortical bone density using clinical CT.

    Science.gov (United States)

    Treece, G M; Gee, A H

    2015-02-01

    The local structure of the proximal femoral cortex is of interest since both fracture risk, and the effects of various interventions aimed at reducing that risk, are associated with cortical properties focused in particular regions rather than dispersed over the whole bone. Much of the femoral cortex is less than 3mm thick, appearing so blurred in clinical CT that its actual density is not apparent in the data, and neither thresholding nor full-width half-maximum techniques are capable of determining its width. Our previous work on cortical bone mapping showed how to produce more accurate estimates of cortical thickness by assuming a fixed value of the cortical density for each hip. However, although cortical density varies much less over the proximal femur than thickness, what little variation there is leads to errors in thickness measurement. In this paper, we develop the cortical bone mapping technique by exploiting local estimates of imaging blur to correct the global density estimate, thus providing a local density estimate as well as more accurate estimates of thickness. We also consider measurement of cortical mass surface density and the density of trabecular bone immediately adjacent to the cortex. Performance is assessed with ex vivo clinical QCT scans of proximal femurs, with true values derived from high resolution HRpQCT scans of the same bones. We demonstrate superior estimation of thickness than is possible with alternative techniques (accuracy 0.12 ± 0.39 mm for cortices in the range 1-3mm), and that local cortical density estimation is feasible for densities >800 mg/cm(3).

  9. Detection of rib metastases in patients with lung cancer: a comparative study of MRI, CT and bone scintigraphy.

    Science.gov (United States)

    Chen, Yan-Qing; Yang, Yang; Xing, Yan-Fen; Jiang, Sen; Sun, Xi-Wen

    2012-01-01

    We retrospectively investigated the imaging findings of bone scintigraphy, chest CT and chest MRI in 55 cases of lung cancer. The sensitivity, specificity and accuracy of the detection of rib metastases were compared between imaging modalities on both a per-lesion and a per-patient basis. On a per-lesion basis, MRI sensitivity and accuracy were significantly higher than that of bone scintigraphy and CT (Pscintigraphy did not differ on either a per-lesion or per-patient basis (P>0.05). MRI appears to be superior for the detection of ribs metastases in lung cancer.

  10. Detection of rib metastases in patients with lung cancer: a comparative study of MRI, CT and bone scintigraphy.

    Directory of Open Access Journals (Sweden)

    Yan-Qing Chen

    Full Text Available We retrospectively investigated the imaging findings of bone scintigraphy, chest CT and chest MRI in 55 cases of lung cancer. The sensitivity, specificity and accuracy of the detection of rib metastases were compared between imaging modalities on both a per-lesion and a per-patient basis. On a per-lesion basis, MRI sensitivity and accuracy were significantly higher than that of bone scintigraphy and CT (P0.05. MRI appears to be superior for the detection of ribs metastases in lung cancer.

  11. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C. [Department of Medical Physics, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 2 Department of Physics and Astronomy, University of Calgary, Calgary T2N 2N4 (Canada); Donnelly, B.J. [Department of Surgery, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 4 Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Saliken, J.C. [Department of Surgery, Tom Baker Cancer Center, Calgary T2N 4N2 (Canada); Department of Diagnostic Imaging, Foothills Hospital, Calgary T2N 2T7 (Canada); McKinnon, J.G. [Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Muldrew, K. [Department of Surgery, Faculty of Medicine, University of Calgary, Calgary T2N 2T7 (Canada)

    2000-05-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  12. Suppression of high-density artifacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Science.gov (United States)

    Baissalov, Roustem; Sandison, George A.; Donnelly, Bryan J.; Saliken, John C.; Muldrew, Ken; Rewcastle, John C.

    2000-06-01

    Image guidance of cryotherapy is usually performed using ultrasound or x-ray CT. Despite the ability of CT to display the full 3D structure of the iceball, including frozen and unfrozen regions, the quality of the images is compromised by the presence of high density streak artifacts. To suppress these artifacts we applied Temporal Digital Subtraction (TDS). This TDS method has the added advantage of improving the gray scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high density artifacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced content of the artifacts. This TDS can be used in x-ray CT assisted cryotherapy to significantly suppress or eliminate high density x-ray CT streak artifacts by digitally processing x-ray CT images. Applying TDS in cryotherapy will facilitate estimation of the amount and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent.

  13. Diagnostic role of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for early and atypical bone metastases.

    Science.gov (United States)

    Chen, Xiao-Liang; Li, Qian; Cao, Lin; Jiang, Shi-Xi

    2014-01-01

    The bone metastasis appeared early before the bone imaging for most of the above patients. (99)Tc(m)-MDP ((99)Tc(m) marked methylene diphosphonate) bone imaging could diagnosis the bone metastasis with highly sensitivity, but with lower specificity. The aim of this study is to explore the diagnostic value of (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging for the early period atypical bone metastases. 15 to 30 mCi (99)Tc(m)-MDP was intravenously injected to the 34 malignant patients diagnosed as doubtful early bone metastases. SPECT, CT and SPECT/CT images were captured and analyzed consequently. For the patients diagnosed as early period atypical bone metastases by SPECT/CT, combining the SPECT/CT and MRI together as the SPECT/MRI integrated image. The obtained SPECT/MRI image was analyzed and compared with the pathogenic results of patients. The results indicated that 34 early period doubtful metastatic focus, including 34 SPECT positive focus, 17 focus without special changes by using CT method, 11 bone metastases focus by using SPECT/CT method, 23 doubtful bone metastases focus, 8 doubtful bone metastases focus, 14 doubtful bone metastases focus and 2 focus without clear image. Totally, SPECT/CT combined with SPECT/MRI method diagnosed 30 bone metastatic focus and 4 doubtfully metastatic focus. In conclusion, (99)Tc(m)-MDP SPECT/CT combined SPECT/MRI Multi modality imaging shows a higher diagnostic value for the early period bone metastases, which also enhances the diagnostic accuracy rate.

  14. Impact of the Adaptive Statistical Iterative Reconstruction Technique on Radiation Dose and Image Quality in Bone SPECT/CT.

    Science.gov (United States)

    Sibille, Louis; Chambert, Benjamin; Alonso, Sandrine; Barrau, Corinne; D'Estanque, Emmanuel; Al Tabaa, Yassine; Collombier, Laurent; Demattei, Christophe; Kotzki, Pierre-Olivier; Boudousq, Vincent

    2016-07-01

    The purpose of this study was to compare a routine bone SPECT/CT protocol using CT reconstructed with filtered backprojection (FBP) with an optimized protocol using low-dose CT images reconstructed with adaptive statistical iterative reconstruction (ASiR). In this prospective study, enrolled patients underwent bone SPECT/CT, with 1 SPECT acquisition followed by 2 randomized CT acquisitions: FBP CT (FBP; noise index, 25) and ASiR CT (70% ASiR; noise index, 40). The image quality of both attenuation-corrected SPECT and CT images was visually (5-point Likert scale, 2 interpreters) and quantitatively (contrast ratio [CR] and signal-to-noise ratio [SNR]) estimated. The CT dose index volume, dose-length product, and effective dose were compared. Seventy-five patients were enrolled in the study. Quantitative attenuation-corrected SPECT evaluation showed no inferiority for contrast ratio and SNR issued from FBP CT or ASiR CT (respectively, 13.41 ± 7.83 vs. 13.45 ± 7.99 and 2.33 ± 0.83 vs. 2.32 ± 0.84). Qualitative image analysis showed no difference between attenuation-corrected SPECT images issued from FBP CT or ASiR CT for both interpreters (respectively, 3.5 ± 0.6 vs. 3.5 ± 0.6 and 3.6 ± 0.5 vs. 3.6 ± 0.5). Quantitative CT evaluation showed no inferiority for SNR between FBP and ASiR CT images (respectively, 0.93 ± 0.16 and 1.07 ± 0.17). Qualitative image analysis showed no quality difference between FBP and ASiR CT images for both interpreters (respectively, 3.8 ± 0.5 vs. 3.6 ± 0.5 and 4.0 ± 0.1 vs. 4.0 ± 0.2). Mean CT dose index volume, dose-length product, and effective dose for ASiR CT (3.0 ± 2.0 mGy, 148 ± 85 mGy⋅cm, and 2.2 ± 1.3 mSv) were significantly lower than for FBP CT (8.5 ± 3.7 mGy, 365 ± 160 mGy⋅cm, and 5.5 ± 2.4 mSv). The use of 70% ASiR blending in bone SPECT/CT can reduce the CT radiation dose by 60%, with no sacrifice in attenuation-corrected SPECT and CT image quality, compared with the conventional protocol using FBP CT

  15. Checking collagen preservation in archaeological bone by non-destructive studies (Micro-CT and IBA)

    Energy Technology Data Exchange (ETDEWEB)

    Beck, L., E-mail: lucile.beck@cea.fr [C2RMF - UMR171 CNRS, Centre de Recherche et de Restauration des Musees de France, Palais du Louvre, Porte des Lions, 14 quai Francois Mitterrand, 75001 Paris (France); CEA, DEN, Service de Recherches de Metallurgie Physique, Laboratoire JANNUS, 91191 Gif-sur-Yvette (France); Cuif, J.-P. [UMR IDES 8148, Universite Paris XI-Orsay, 91405 Orsay cedex (France); Pichon, L. [C2RMF - UMR171 CNRS, Centre de Recherche et de Restauration des Musees de France, Palais du Louvre, Porte des Lions, 14 quai Francois Mitterrand, 75001 Paris (France); Vaubaillon, S. [CEA, INSTN, Laboratoire JANNUS, 91191 Gif-sur-Yvette (France); Dambricourt Malasse, A. [Departement de Prehistoire, Museum national d' Histoire naturelle, UMR 7194 - CNRS, Institut de Paleontologie Humaine, 1, rue Rene Panhard, 75013 Paris (France); Abel, R.L. [The Natural History Museum, London (United Kingdom)

    2012-02-15

    The material to be studied is a piece of human skull discovered (1999) in Pleistocene sediments from the Orsang river (Gujarat state, India). From anatomical view point, this skull is highly composite: modern Homo sapiens characters are associated to undoubtedly more ancient features. Absolute dating by {sup 14}C is critical to understand this discovery. Prior to dating measurements, non-destructive studies have been carried out. Micro-CT reconstruction (X-ray microtomography) and Ion Beam Analysis (IBA) have been undertaken to check the structural preservation of the fossil and the collagen preservation. PIXE elemental map was used to select well-preserved bone area. RBS/EBS and NRA were used for light element quantification, in particular C, N and O contents. We also demonstrate that the PIXE-RBS/EBS combination is a effective tool for the whole characterization of archaeological and recent bones by analysing in one experiment both mineral and organic fractions. We have shown that the archaeological bone, a fragment of the potentially oldest modern Indian, is enough preserved for radiocarbon dating. We propose that Elastic Backscattering Spectrometry (EBS) using 3 MeV protons could be a good non destructive alternative to conventional CHN method using Carbon-Hydrogen-Nitrogen analyzer for measuring C and N before {sup 14}C dating.

  16. Giant Cell Tumor of the Temporal Bone with Direct Invasion into the Middle Ear and Skull Base: A Case Report

    Directory of Open Access Journals (Sweden)

    Takashi Iizuka

    2012-01-01

    Full Text Available Giant cell tumor (GCT is classified as a benign bone tumor, and it is frequently identified at the epiphysis of long bones and relatively rare in the temporal bone. For orthopedists expert at recognizing bone and soft tissue tumors, the diagnosis of GCT is relatively easy; however, since head and neck surgeons experience few cases of GCT, it may be difficult to diagnose when it occurs in the temporal bone. A 32-year-old man complained of left hearing loss, aural fullness, and tinnitus. Examination of the ear revealed a bulging tumor. Audiologic examination demonstrated conductive hearing loss of the left ear. Computer tomograph of the temporal bone showed a soft-tissue-density specification indicating bone destruction at the left temporal bone. The tumor invaded the skull base. Imaging examinations using magnetic resonance imaging revealed a nonhomogenous isosignal intensity area on T1 at the left temporal bone. After intravenous gadolinium, the mass showed unequal enhancement. This patient subsequently underwent surgery to remove the lesion using transmastoid and middle fossa approach. Pathological examinations from specimens of the tumor revealed characteristic of GCT. No clinical or radiological evidence of tumor recurrence was detected for 4 years.

  17. Micro-CT evaluation and histological analysis of screw-bone interface of expansive pedicle screw in osteoporotic sheep

    Institute of Scientific and Technical Information of China (English)

    WAN Shi-yong; LEI Wei; WU Zi-xiang; L(U) Rong; WANG Jun; FU Suo-chao; LI Bo; ZHAN Ce

    2008-01-01

    To investigate the properties of screwbone interface of expansive pedicle screw(EPS)in osteoporotic sheep by micro-CT and histological observation.Methods:Six female sheep with bilateral ovariectomyinduced osteoporosis were employed in this experiment.After EPS insertion in each femoral condvle, the sheep were randomly divided into two groups:3 sheep were bred for 3 months(Group A),while the other 3 were bred for 6 months(Group B). After the animals being killed,the femoral condyles with EPS were obtained,which were three-dimensionally-imaged and reconstructed by micro-CT. Histological evaluation was made thereafter.Results:The trabecular microstructure was denser at the screw-bone interface than in the distant parts in expansive section,especially within the spiral marking.In the nonexpansive section,however,there was no significant difference between the interface and the distant parts. The regions of interest(ROI)adjacent to EPS were reconstructed and analyzed by micro-CT with the same thresholds. The three-dimensional(3-D)parameters,including tissue mineral density(TMD),bone volume fraction(BVF,BV/TV),bone surface/bone volume(BS/BV) ratio, trabecular thickness(Tb. Th),and trabecular separation(Tb. Sp),were significantly better in expansive sections than non-expansive sections(P<0.05).Histologically,newly-formed bony trabeculae crawled along the expansive fissures and into the center of EPS. The newly-formed bones,as well as the bones at the bone-screw interface,closely contacted with the EPS and constructed four compartments.Conclusions:The findings of the current study,based on micro-CT and histological evaluation, suggest that EPS can significantly provide stabilization in osteoporotic cancellous bones.

  18. A quantitative CT system applied to the femoral shaft and lateral condyle for evaluating bone loss in patients with secondary hyperparathyroidism

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, Kiyoko [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Allied Health Sciences; Matsubayashi, Takashi; Tsukamoto, Yusuke

    1996-09-01

    An improved quantitative CT (QCT) system for evaluating bone loss was reported, which was based on the 3 parameters newly made obtainable on the CT scanner of BOCT (bone CT number, the mean CT number within bone region). PKCT (peak CT number, CT number at the peak of the frequency distribution of CT numbers in the histogram) and MXCT (maximum CT number within bone region). Subjects were 37 patients, who were treated with ordinary dose of 1,25(OH{sub 2})D{sub 3} or were of more progressed symptoms, and 87 normal healthy volunteers. A Quantex apparatus (YMS Co.) was used for CT scanning with the tube voltage of 120 kVp for the femoral shaft and 80 kVp for lateral condyle and vertebra and with slice thickness of 10 mm. A phantom consisting of an aluminum pipe inserted in an acrylic acid resin column was used to obtain the standard CT number, and the standard phantom of the BMD (bone mineral density) package (YMS Co.), in the QCT of the femoral lateral condyles. Results were analyzed by SAS statistical program. The 3 parameters together with BMD were found quite useful far evaluating bone loss in all patients. (K.H.)

  19. Impact of micronutrients supplementation on bone repair around implants: microCT and counter-torque analysis in rats

    Science.gov (United States)

    Pimentel, Suzana Peres; Casarin, Renato Correa; Ribeiro, Fernanda Vieira; Cirano, Fabiano Ribeiro; Rovaris, Karla; Haiter, Francisco; Casati, Marcio Zaffalon

    2016-01-01

    ABSTRACT The use of natural substances and micronutritional approaches has been suggested as a therapeutic alternative to benefit the bone healing associated with no side effects. Nevertheless, the influence of micronutritional interventions with therapeutic proprieties on the bone repair has yet to be intensely evaluated, and no evidence is available exploring the impact of micronutrient supplementation on the peri-implant bone healing. Objective This study investigated the effect of micronutrients supplementation on the bone repair around implants. Material and Methods One screw-shaped titanium implant was inserted in each tibia of each rat, which were assigned to: daily administration, for 30 d, of the placebo solution (Placebo group-n:18) or micronutrients supplementation (Micronutrients group-n:18), based on calcium, magnesium, zinc, and vitamin D3 intake. After, the animals were sacrificed. One of the implants was removed by applying a counter-torque force to evaluate the force to rupture the bone-implant interface. The other implant was evaluated by microcomputed tomography (CT) examination to determine the bone-to-implant contact (BIC) and the bone volume (BV/TV). Results No statistically significant differences were observed between the groups for both counter-torque values and microCT parameters (p>0.05). Conclusion Within the limits of this study, micronutrients supplementation did not provide additional benefits to the bone healing around dental implants. PMID:27008256

  20. Impact of micronutrients supplementation on bone repair around implants: microCT and counter-torque analysis in rats

    Directory of Open Access Journals (Sweden)

    Suzana Peres Pimentel

    2016-02-01

    Full Text Available ABSTRACT The use of natural substances and micronutritional approaches has been suggested as a therapeutic alternative to benefit the bone healing associated with no side effects. Nevertheless, the influence of micronutritional interventions with therapeutic proprieties on the bone repair has yet to be intensely evaluated, and no evidence is available exploring the impact of micronutrient supplementation on the peri-implant bone healing. Objective This study investigated the effect of micronutrients supplementation on the bone repair around implants. Material and Methods One screw-shaped titanium implant was inserted in each tibia of each rat, which were assigned to: daily administration, for 30 d, of the placebo solution (Placebo group-n:18 or micronutrients supplementation (Micronutrients group-n:18, based on calcium, magnesium, zinc, and vitamin D3 intake. After, the animals were sacrificed. One of the implants was removed by applying a counter-torque force to evaluate the force to rupture the bone-implant interface. The other implant was evaluated by microcomputed tomography (CT examination to determine the bone-to-implant contact (BIC and the bone volume (BV/TV. Results No statistically significant differences were observed between the groups for both counter-torque values and microCT parameters (p>0.05. Conclusion Within the limits of this study, micronutrients supplementation did not provide additional benefits to the bone healing around dental implants.

  1. Dental CT and orthodontic implants: imaging technique and assessment of available bone volume in the hard palate

    Energy Technology Data Exchange (ETDEWEB)

    Gahleitner, Andre E-mail: andre.gahleitner@univie.ac.at; Podesser, Birgit; Schick, Susanne; Watzek, Georg; Imhof, Herwig

    2004-09-01

    Purpose: Palatal implants (PI) have been introduced for orthodontic treatment of dental and skeletal dysgnathia. Due to the restricted amount of bone in this region, precise preoperative anatomic information is necessary. The aim of this study was to determine whether dental CT could serve as a tool to locate the optimal size and position for orthodontic implant placement. Materials and methods: In 32 patients, where palatal implant placement was planned, axial CT scans of the maxillary bone were acquired. Using a standard dental software package (Easy Vision dental software package 2.1, Philips; Best, The Netherlands), paracoronal views were reconstructed and measurements of palatal bone height in 3 mm increments, dorsally from the incisive canal, were performed in the median and both paramedian regions. Results: The overall mean bone height was 5.01 mm (S.D. 2.60), ranging from 0 to 16.9 mm. The maximum palatal bone height was 6.17 mm (S.D. 2.81) at 6 mm dorsally from the incisive canal. Due to the lack of adequate bone (less than 4 mm), implant placement was not performed in 3 cases (7%). In the remaining 39 cases (93.0%), primary implant stability was achieved and complications, such as perforation of the palate, could be avoided. Conclusion: The results demonstrate that dental CT promises to be a valuable tool in evaluating the potential and optimal size and site for orthodontic implant placement.

  2. Preoperative assessment of the cancellous bone mineral density of the proximal humerus using CT data

    Energy Technology Data Exchange (ETDEWEB)

    Krappinger, Dietmar; Roth, Tobias; Gschwentner, Martin; Suckert, Armin; Blauth, Michael; Hengg, Clemens; Kralinger, Franz [Innsbruck Medical University, Department of Trauma Surgery and Sports Medicine, Innsbruck (Austria)

    2012-03-15

    Osteoporotic fractures of the proximal humerus show an increasing incidence. Osteoporosis not only influences the fracture risk after low-energy trauma, but also affects the mechanical stability of internal fixation. Preoperative assessment of the local bone quality may be useful in the surgical treatment of patients sustaining these injuries. The aim of the present study was to present a method for the preoperative assessment of the local cancellous bone mineral density (BMD) of the proximal humerus using CT data. In the first part of the study, CT scans of 30 patients with unilateral fractures of the proximal humerus after low-energy trauma were used. The local BMD was assessed on the contralateral uninjured side. All 30 patients additionally underwent dual-emission X-ray absorptiometry (DXA) of the lumbar spine, proximal femur, and forearm of the side of the uninjured proximal humerus within 6 weeks after trauma. Three independent trauma surgeons performed measurements on the uninjured proximal humerus twice with a time interval of 4 weeks in order to assess the inter- and intraobserver reliability of the method. In the second part of the study, the local BMD of 507 patients with either proximal humerus fractures or chronic shoulder instability was assessed by a single trauma surgeon. In both parts, the average HU values in standardized ROIs of the humeral head were automatically calculated after correcting for HU values below the water equivalent. A linear calibration equation was computed for the calculation from HU to BMD using a calibration device (EFP). The intra- and interobserver reliability was high (ICC > 0.95). Correlation coefficients between the local BMD of the proximal humerus and other anatomical sites were between 0.35 (lumbar spine) and 0.64 (forearm). We found a high correlation between the local BMD and age. The BMD in the fracture group was significantly lower than in the instability group. These patients were significantly older and more

  3. SPECT/CT 骨显像对颞下颌关节紊乱综合征的临床研究%Clinical research of SPECT/CT bone imaging on temporo-mandibular joint dysfunction syndrome

    Institute of Scientific and Technical Information of China (English)

    史聪翀; 刘超

    2015-01-01

    目的:研究放射性核素骨显像对颞下颌关节紊乱综合征的诊断价值。方法对36例颞下颌关节综合征患者行 SPECT/ CT 骨显像,对颞下颌关节的髁状突、下颌升支、下颌角图像进行冠状面、矢状面、横断面采集重建,并计算放射性计数比值。结果骨显像患侧颞下颌关节髁状突、下颌升支、下颌角放射性计数比值分别为6.23±0.59,3.42±0.14,2.75±0.63,与健侧比较差异均有统计学意义(P <0.05)。结论放射性核素骨扫描对颞下颌关节紊乱病的早期器质性病变是很好的检测手段,可以早期发现骨质的细小破坏,从而为选择治疗方法提供参考。%Objective To study the diagnostic value of radionuclide bone imaging on temporo-mandibular joint dysfunction syndrome(TMJD). Methods Conducted SPECT/ CT bone imaging on 36 TMJD patients,gathered and rebuilt coronal plane, vertical plane and transaction of temporal-mandibular joint,mandibular ramus,angle of mandible images,and calculated the ra-dioactive count ratios. Results The radioactive count ratios of bone imaging affected side’s temporal-mandibular joint,mandibu-lar ramus,angle of mandible were 6. 23 ±0. 59,3. 42 ±0. 14 and 2. 75 ±0. 63 respectively,and they had significant difference than those of uninjured side(P <0. 05). Conclusion Radionuclide bone scanning is a good detection method for early temporomandib-ular disorders,so it can early detection of bone damage and provide reference evidence for the choice of treatment method.

  4. Temporal gene expression profiling during rat femoral marrow ablation-induced intramembranous bone regeneration.

    Directory of Open Access Journals (Sweden)

    Joel K Wise

    Full Text Available Enhanced understanding of differential gene expression and biological pathways associated with distinct phases of intramembranous bone regeneration following femoral marrow ablation surgery will improve future advancements regarding osseointegration of joint replacement implants, biomaterials design, and bone tissue engineering. A rat femoral marrow ablation model was performed and genome-wide microarray data were obtained from samples at 1, 3, 5, 7, 10, 14, 28, and 56 days post-ablation, with intact bones serving as controls at Day 0. Bayesian model-based clustering produced eight distinct groups amongst 9,062 significant gene probe sets based on similar temporal expression profiles, which were further categorized into three major temporal classes of increased, variable, and decreased expression. Osteoblastic- and osteoclastic-associated genes were found to be significantly expressed within the increased expression groups. Chondrogenesis was not detected histologically. Adipogenic marker genes were found within variable/decreased expression groups, emphasizing that adipogenesis was inhibited during osteogenesis. Differential biological processes and pathways associated with each major temporal group were identified, and significantly expressed genes involved were visually represented by heat maps. It was determined that the increased expression group exclusively contains genes involved in pathways for matrix metalloproteinases (MMPs, Wnt signaling, TGF-β signaling, and inflammatory pathways. Only the variable expression group contains genes associated with glycolysis and gluconeogenesis, the notch signaling pathway, natural killer cell mediated cytotoxicity, and the B cell receptor signaling pathway. The decreased group exclusively consists of genes involved in heme biosynthesis, the p53 signaling pathway, and the hematopoietic cell lineage. Significant biological pathways and transcription factors expressed at each time point post

  5. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using {sup 18F} FDG PET/CT and {sup 99mT}c HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent {sup 99mT}c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  6. Suture restriction of the temporal bone as a risk factor for acute otitis media in children: cohort study

    Directory of Open Access Journals (Sweden)

    Morin Chantal

    2012-11-01

    Full Text Available Abstract Background Eustachian tube (ET dysfunction plays an important role in the pathogenesis of acute otitis media (AOM. Unfortunately, there is a lack of knowledge about the exact role of the ET’s bony support, the temporal bone, on occurrence of AOM. This study investigates whether severe suture restriction of the temporal bone is a risk factor for development of AOM in young children. Methods Using a prospective cohort design, 64 children aged 6 to 18 months without prior history of AOM were followed during the cold season (September 2009 to April 2010. Temporal bone status (categorized as with or without severe suture restriction was evaluated using palpation and a cranial bone mobility test. Information about potential baseline confounders and risk factors for AOM (gender, age, birth weight, gestational age, use of pacifier, daycare attendance, presence of siblings, low socioeconomic status, breastfeeding ≥ 6 months, parental smoking and history of upper respiratory tract infection were also collected. Occurrence of AOM diagnosed by physicians blinded to temporal bone status was the main outcome. Data were analyzed using hierarchical linear and nonlinear (multilevel models. Results Severe suture restriction of the temporal bone was identified in 23 children (35.9%. At least one AOM episode was diagnosed in 14 (48.3% of the ears associated with temporal bones previously identified as having severe suture restriction and in 28 (28.3% of those without severe suture restriction. Higher risk for AOM was explained by severe suture restriction of the temporal bone (adjusted relative risk (RR, 2.26, 95% CI 1.43 to 2.91, p Conclusions The study results indicate that severe suture restriction of the temporal bone is a risk factor for AOM in young children. Subsequent intervention studies are needed to determine if this mechanical risk factor can be modified in young children.

  7. Temporal bone MRI with 3D-FIESTA in the evaluation of facial and audiovestibular dysfunction.

    Science.gov (United States)

    Cavusoglu, M; Cılız, D S; Duran, S; Ozsoy, A; Elverici, E; Karaoglanoglu, R; Sakman, B

    2016-09-01

    To evaluate the clinical usefulness of magnetic resonance imaging (MRI) of the temporal bone using three-dimensional fast imaging employing steady-state acquisition (3D-FIESTA) sequences in patients with facial and audiovestibular dysfunction. We retrospectively reviewed the MR images of 1263 patients who presented with hearing loss (n=429), peripheral facial palsy (n=96), tinnitus (n=341) or vertigo (n=397). There were 605 men and 658 women, with a mean age of 46.97±16.95 (SD) years (range: 2-83 years). Positive MRI findings that were responsible for clinical manifestations in individual patients were categorized according to the anatomic sites and etiologies of the lesions. Positive MRI findings possibly responsible for clinical manifestations were found in 232/1263 (18.37%) patients, including 86/429 (20.05%) patients with hearing loss, 21/96 (21.88%) patients with facial palsy, 62/341 (18.18%) patients with tinnitus, and 63/397 (15.87%) patients with vertigo. Although the use of MRI of the temporal bone using 3D-FIESTA shows positive findings in only 18.37% of patients, it provides important information in those with facial and audiovestibular dysfunction. However, for patients with normal MRI of the temporal bone, other etiological factors should be investigated in order to clarify or elucidate the cause of clinical manifestations. Copyright © 2015 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  8. Inflammation and tumors of the temporal bone; Entzuendungen und Tumoren des Schlaefenbeins

    Energy Technology Data Exchange (ETDEWEB)

    Burian, M. [Universitaetsklinik fuer Hals-, Nasen- und Ohrenkrankheiten, Allgemeines Krankenhaus, Wien (Austria)

    1997-12-01

    The term `inflammation of the middle ear` covers a couple of deseases which range from the acute otitis media to the middle ear cholesteatoma. However, a clear characterization of a certain pathology is essential for any further treatment. Therefore this article presents a short overview about the different types of infections and their clinical manifestation. The tumors of the temporal bone show a great variety in their incidence. Even if tumors like the acoustic neurinoma or the paraganglioma are compareable common, the chondroblastoma of the temporal bone is absolutely rare. In spite of these differences the individual temporal bone neoplasias are shortly mentioned herein. (orig.) [Deutsch] Der Begriff Mittelohrentzuendung umfasst ein weites Spektrum von Krankheiten welches von der akuten Mittelohrentzuendung bis hin zum Cholesteatom reicht. Es soll in diesem Artikel eine kurze Uebersicht ueber die verschiedenen Entzuendungen gegeben werden, wobei vor allem auf eine klare Begriffsdefinition der einzelnen Entzuendungsformen und deren klinisches Erscheinungsbild geachtet wurde. Bei den Tumoren des Schlaefenbeins ist ein grosser Unterschied in der Inzidenz der einzelnen Tumoren gegeben. Waehrend Neubildungen wie das Akustikusneurinom oder das Paragangliom vergleichsweise haeufig im klinischen Alltag zu sehen sind, stellen Veraenderungen wie das Chondroblastom eine Raritaet dar. Trotz dieses Unterschieds im Vorkommen der verschiedenen Tumoren, wurde versucht, einen kurzen Gesamtueberblick ueber die Tumore des Mittel- und Innenohres zu geben. (orig.)

  9. PET Index of Bone Glucose Metabolism (PIBGM) Classification of PET/CT Data for Fever of Unknown Origin Diagnosis.

    Science.gov (United States)

    Yang, Jian; Liu, Xinxin; Ai, Danni; Fan, Jingfan; Zheng, Youjing; Li, Fang; Huo, Li; Wang, Yongtian

    2015-01-01

    Fever of unknown origin (FUO) remains a challenge in clinical practice. Fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is helpful in diagnosing the etiology of FUO. This paper aims to develop a completely automatic classification method based on PET/CT data for the computer-assisted diagnosis of FUO. We retrospectively analyzed the FDG PET/CT scan of 175 FUO patients, 79 males and 96 females. The final diagnosis of all FUO patients was achieved through pathology or clinical evaluation, including 108 normal patients and 67 FUO patients. CT anatomic information was used to acquire bone functional information from PET images. The skeletal system of FUO patients was classified by analyzing the standardized uptake value (SUV) and the PET index of bone glucose metabolism (PIBGM). The SUV distributions in the bone marrow and the bone cortex were also studied in detail. The SUV and PIBGM of the bone marrow only slightly differed between the FUO patients and normal people, whereas the SUV of whole bone structures and the PIBGM of the bone cortex significantly differed between the normal people and FUO patients. The method detected 43 patients from 67 FUO patients, with sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 64.18%, 95%, 93.48%, 72.73%, and 83.33%, respectively. The experimental results demonstrate that the study can achieve automatic classification of FUO patients by the proposed novel biomarker of PIBGM, which has the potential to be utilized in clinical practice.

  10. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil); Yamaguchi, Nise Hitomi [Instituto Avanços em Medicina (Brazil); Leite, Claudia Costa; Cerri, Giovanni Guido; Menezes, Marcos Roberto de, E-mail: marcos.menezes@hc.fm.usp.br [Sírio Libânes Hospital, Radiology and Imaged Guided Intervention Service (Brazil)

    2016-02-15

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  11. Radiography, Bone Scan, and F-18 FDG PET/CT Imaging Findings in a Patient with Paget's Disease

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun Tae; Kim, Sung Eun [Korea University Guro Hospital, Seoul (Korea, Republic of)

    2010-04-15

    Background A 52-year-old female patient sought evaluation at our hospital for an incidental abnormal finding on an abdominal radiograph. The initial radiograph showed irregular sclerotic changes involving the right pelvic bone. At the same time, bone scintigraphy showed intense hot uptake in the right iliac and pubic bones. CT images showed characteristic thickening of the pelvic brim, suggesting the mixed phase of Paget's disease. The level of alkaline phosphatase (ALP) was 266 IU/I. {sup 18}F-FDG PET/CT images also showed diffusely increased {sup 18}F-FDG uptake in the right pelvic bone. However, the findings of {sup 18}F-FDG PET/CT were less notable than those of bone scintigraphy. We report the imaging findings of a patient with Paget's disease evaluated by radiography, bone scintigraphy, and {sup 18}F-FDG PET/CT.

  12. Spinal aneurysmal bone cyst causing acute cord compression without vertebral collapse: CT and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Monica S.M.; Wong, Yiu-Chung; Yuen, Ming-Keung [Department of Diagnostic Radiology, Tuen Mun Hospital, Hongkong (China); Lam, Dicky [Department of Orthopaedics and Traumatology, Hongkong (China)

    2002-08-01

    Aneurysmal bone cyst (ABC) of the spine can cause acute spinal cord compression in young patients. We report the CT and MRI findings in a histology-proven case of spinal ABC presenting with sudden paraplegia. Typical features of a spinal ABC at the thoracic level with considerable extension into the posterior epidural space and cord compression were demonstrated. Special note was made of the disproportionately large longitudinal extent of the epidural component of the lesion. Associated vertebral collapse was absent. A fracture of the overlying cortex had probably allowed the lesion to decompress and track along the epidural space without significantly jeopardizing integrity of the osseous structures. This case illustrates a less frequently recognised mechanism of acute spinal cord compression by ABC. (orig.)

  13. Morphometrical Study of the Temporal Bone and Auditory Ossicles in Guinea Pig

    Directory of Open Access Journals (Sweden)

    Ahmadali Mohammadpour

    2011-03-01

    Full Text Available In this research, anatomical descriptions of the structure of the temporal bone and auditory ossicles have been performed based on dissection of ten guinea pigs. The results showed that, in guinea pig temporal bone was similar to other animals and had three parts; squamous, tympanic and petrous .The tympanic part was much better developed and consisted of oval shaped tympanic bulla with many recesses in tympanic cavity. The auditory ossicles of guinea pig concluded of three small bones; malleus, incus and stapes but the head of the malleus and the body of incus were fused and forming a malleoincudal complex. The average of morphometric parameters showed that the malleus was 3.53 ± 0.22 mm in total length. In addition to head and handle, the malleus had two distinct process; lateral and muscular. The incus had a total length 1.23 ± 0.02mm. It had long and short crus although the long crus was developed better than short crus. The lenticular bone was a round bone that articulated with the long crus of incus. The stapes had a total length 1.38 ± 0.04mm. The anterior crus(0.86 ± 0.08mm was larger than posterior crus (0.76 ± 0.08mm. It is concluded that, in the guinea pig, the malleus and the incus are fused, forming a junction called incus-malleus, while in the other animals these are separate bones. The stapes is larger and has a triangular shape and the anterior and posterior crus are thicker than other rodents. Therefore, for otological studies, the guinea pig is a good lab animal.

  14. Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study

    NARCIS (Netherlands)

    Ibrahim, N.; Parsa, A.; Hassan, B.; van der Stelt, P.; Aartman, I.H.A.; Nambiar, P.

    2014-01-01

    The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre,

  15. Influence of object location in different FOVs on trabecular bone microstructure measurements of human mandible: a cone beam CT study

    NARCIS (Netherlands)

    Ibrahim, N.; Parsa, A.; Hassan, B.; van der Stelt, P.; Aartman, I.H.A.; Nambiar, P.

    2014-01-01

    The aim of this study was to assess the influence of different object locations in different fields of view (FOVs) of two cone beam CT (CBCT) systems on trabecular bone microstructure measurements of a human mandible. A block of dry human mandible was scanned at five different locations (centre, lef

  16. Healed or non-healed? computed tomography (CT) visualisation of morphology of bite trace ichnotaxa on a dinosaur bone

    DEFF Research Database (Denmark)

    Jacobsen, Aase Roland; Lauridsen, Henrik; Fiirgaard, Bente

    2015-01-01

    examined by correlating traditional naked-eye in spection with computed to mography (CT) imaging, used to visualise the internal morphology of the bite traces and in particular, to clarify the appearance of one possibly healed bite trace. A forensic pathologist visually examined the bone with the aid...

  17. CT scan evaluation of glenoid bone and pectoralis major tendon: interest in shoulder prosthesis

    Science.gov (United States)

    Obert, Laurent; Peyron, Christelle; Boyer, Etienne; Menu, Gauthier; Loisel, François; Aubry, Sébastien

    2016-01-01

    Introduction: The shoulder arthroplasty brings satisfaction to patients in terms of quality of life and indolence. However whether anatomic implant or reverse, it does not escape from the loosening of the glenoid component. Moreover, optimal implantation is required to ensure the functional outcome without shortening of the arm. The purpose of this study is obtain CT scan evaluation of the glenoid bone stock in order to optimize glenoid component implantation and obtain a reference to determine optimal humeral component placement in case of humeral proximal fracture. Materials and methods: Between 2010 and 2011 we have analyzed 200 intact shoulder’s CT. We measured maximal and minimal width in the transverse plane of the glenoid, the distance from the pectoralis major (PM) tendon to the humeral head, the greater tubercle, change of curvature and the anatomical neck. Results: Mean maximum width was 27.4 ± 3.4 mm and mean minimum width was 15.5 ± 2.8 mm. Distances between upper edge of PM tendon to: humeral head, greater tubercle, change of curvature and anatomical neck were respectively: 67.6 ± 9.98 mm, 57.8 ± 10.3 mm, 28.7 ± 9 mm, and 34.2 ± 9.7 mm. Conclusion: Our study has produced an assessment of glenoid bone stock for optimal positioning of the glenoid implant but also to obtain a reference to determine the ideal location of the humeral component in the case of proximal humerus fracture. PMID:27716461

  18. Micro-CT studies on 3-D bioactive glass-ceramic scaffolds for bone regeneration.

    Science.gov (United States)

    Renghini, Chiara; Komlev, Vladimir; Fiori, Fabrizio; Verné, Enrica; Baino, Francesco; Vitale-Brovarone, Chiara

    2009-05-01

    The aim of this study was the preparation and characterization of bioactive glass-ceramic scaffolds for bone tissue engineering. For this purpose, a glass belonging to the system SiO2-P2O5-CaO-MgO-Na2O-K2O (CEL2) was used. The sponge-replication method was adopted to prepare the scaffolds; specifically, a polymeric skeleton was impregnated with a slurry containing CEL2 powder, polyvinyl alcohol (PVA) as a binding agent and distilled water. The impregnated sponge was then thermally treated to remove the polymeric phase and to sinter the inorganic one. The obtained scaffolds possessed an open and interconnected porosity, analogous to cancellous bone texture, and with a mechanical strength above 2 MPa. Moreover, the scaffolds underwent partial bioresorption due to ion-leaching phenomena. This feature was investigated by X-ray computed microcomputed tomography (micro-CT). Micro-CT is a three-dimensional (3-D) radiographic imaging technique, able to achieve a spatial resolution close to 1 microm(3). The use of synchrotron radiation allows the selected photon energy to be tuned to optimize the contrast among the different phases in the investigated samples. The 3-D scaffolds were soaked in a simulated body fluid (SBF) to study the formation of hydroxyapatite microcrystals on the scaffold struts and on the internal pore walls. The 3-D scaffolds were also soaked in a buffer solution (Tris-HCl) for different times to assess the scaffold bioresorption according to the ISO standard. A gradual resorption of the pores walls was observed during the soakings both in SBF and in Tris-HCl.

  19. A prospective study comparing (99m)Tc-HDP planar bone scintigraphy and whole-body SPECT/CT with (18)F-fluoride PET/CT and (18)F-fluoride PET/MRI for diagnosing bone metastases.

    Science.gov (United States)

    Löfgren, Johan; Mortensen, Jann; Rasmussen, Sine Hvid; Madsen, Claus; Loft, Annika; Hansen, Adam Espe; Oturai, Peter; Jensen, Karl Erik; Mørk, Mette Louise; Reichkendler, Michala; Højgaard, Liselotte; Fischer, Barbara M

    2017-08-10

    We prospectively evaluate and compare the diagnostic performance of (99m)Tc-HDP planar bone scintigraphy (pBS), (99m)Tc-HDP SPECT/CT, (18)F-NaF PET/CT and (18)F-NaF PET/MRI for the detection of bone metastases. Methods: 117 patients with histologically proven malignancy referred for clinical pBS were prospectively enrolled. pBS and whole-body SPECT/CT were performed followed by (18)F-NaF PET/CT within 9 days. (18)F-NaF PET/MRI was also performed in 46 patients. A "truth panel" including clinical follow-up served as standard of reference. Results: Bone metastases were confirmed in 16 patients and excluded in 101. When equivocal readings were excluded no statistically significant difference in sensitivity, specificity, PPV, NPV or overall accuracy were found when comparing the different imaging techniques. With a pessimistic analysis, interpreting equivocal scans as positive, (18)F-NaF-PET showed a significant higher specificity and accuracy than pBS (93.1% vs 81.2%, P = 0.012 and 91.5% vs. 79.5%, P = 0.011). With an optimistic analysis, interpreting equivocal scans as negative, (18)F-NaF-PET showed significant higher accuracy than SPECT/CT (94.9% vs. 88.0%, P = 0.039) but not compared to pBS. The number of equivocal scans were significantly higher for pBS than for SPECT/CT and PET/CT (18 vs 5 and 6 respectively, P = 0.004 resp. P = 0.01). Conclusion:(18)F-NaF PET/CT and whole body SPECT/CT resulted in a significant reduction of equivocal readings compared to pBS which implies an improved diagnostic confidence. However, this large prospective study could not verify prior published results on (18)F-NaF-PET/CT superior overall accuracy compared to neither pBS nor whole-body SPECT/CT. The subgroup analysis of 46 patients with (18)F-NaF-PET/MRI failed to demonstrate significantly improved overall diagnostic accuracy. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  20. Temporal evolution of multidetector CT findings after endoscopic submucosal dissection in patients with early gastric cancer: Correlation with endoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, Dong Myung, E-mail: duehdaud@gmail.com [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Chung, Dong Jin, E-mail: bookdoo7@catholic.ac.kr [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Cheung, Dae Young, E-mail: adagio@catholic.ac.kr [Department of Internal Medicine, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Lee, Jae Mun, E-mail: jaemun@catholic.ac.kr [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of)

    2014-06-15

    Objective: To assess changes over time in imaging findings retrospectively by multidetector CT (MDCT) with two-dimensional (2D) multiplanar reconstruction and three-dimensional (3D) CT gastrography (CTG), after endoscopic submucosal dissection (ESD) in patients with early gastric cancer (EGC), and to correlate 3D CT images with endoscopic appearance. Materials and methods: In this retrospective study, a total of 84 patients underwent ESD and were followed up with MDCT. Fifteen patients underwent CT twice, and 3 patients underwent CT 3 times. A total of 105 CTs were included in this study and 43 CTs contained 3D CTGs. Two radiologists in consensus interpreted CT images for lesion detectability, presence and characteristics of ulcer, focal wall thickening, perigastric fat infiltration, and overlying enhancing layer in 2D images. The presence of ulcer or subtle mucosal nodularity, ulcer mound, and fold convergence were analysed in 3D CT images. We also assessed the time interval between ESD and CT and analysed the temporal evolution of CT findings. The sensitivity, specificity, and overall accuracy of 3D CTG were assessed regarding endoscopic features as the gold standard. Results: The mean interval between ESD and follow up CT was 76.9 days (median, 62; range, 2–223). No tumour recurrence in any lesion was found on follow-up endoscopic biopsy and also lymph node or distant metastasis was not observed on CT exams in the follow-up period. The lesion detectability in a total of 105 post-ESD 2D CT images was 42.0% (44/105), and 93.2% (41/44) of the detected lesions were visualizable 2 months after ESD. Focal wall thickening was observed during the entire follow-up period in all patients. Perigastric fat infiltration was observed in 4 lesions within 1 week of ESD. Overlying enhancing layer appeared in 27 lesions without temporal evolution. On a total of 43 post-ESD 3D CTG, lesion detectability was 76.7% (33/43), and lesions could be visualized for a longer period than

  1. Clinical Application of Solid Model Based on Trabecular Tibia Bone CT Images Created by 3D Printer.

    Science.gov (United States)

    Cho, Jaemo; Park, Chan-Soo; Kim, Yeoun-Jae; Kim, Kwang Gi

    2015-07-01

    The aim of this work is to use a 3D solid model to predict the mechanical loads of human bone fracture risk associated with bone disease conditions according to biomechanical engineering parameters. We used special image processing tools for image segmentation and three-dimensional (3D) reconstruction to generate meshes, which are necessary for the production of a solid model with a 3D printer from computed tomography (CT) images of the human tibia's trabecular and cortical bones. We examined the defects of the mechanism for the tibia's trabecular bones. Image processing tools and segmentation techniques were used to analyze bone structures and produce a solid model with a 3D printer. These days, bio-imaging (CT and magnetic resonance imaging) devices are able to display and reconstruct 3D anatomical details, and diagnostics are becoming increasingly vital to the quality of patient treatment planning and clinical treatment. Furthermore, radiographic images are being used to study biomechanical systems with several aims, namely, to describe and simulate the mechanical behavior of certain anatomical systems, to analyze pathological bone conditions, to study tissues structure and properties, and to create a solid model using a 3D printer to support surgical planning and reduce experimental costs. These days, research using image processing tools and segmentation techniques to analyze bone structures to produce a solid model with a 3D printer is rapidly becoming very important.

  2. Bone metastases from breast cancer: associations between morphologic CT patterns and glycolytic activity on PET and bone scintigraphy as well as explorative search for influential factors.

    Science.gov (United States)

    Sugihara, Tsutomu; Koizumi, Mitsuru; Koyama, Masamichi; Terauchi, Takashi; Gomi, Naoya; Ito, Yoshinori; Hatake, Kiyohiko; Sata, Naohiro

    2017-09-01

    This study aimed to compare the detection of bone metastases from breast cancer on F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and bone scintigraphy (BS). An explorative search for factors influencing the sensitivity or uptake of BS and FDG-PET was also performed. Eighty-eight patients with bone metastases from breast cancer were eligible for this study. Histological confirmation of bone metastases was obtained in 31 patients. The bone metastases were visually classified into four types based on their computed tomography (CT) appearance: osteoblastic, osteolytic, mixed, and negative. The sensitivity of BS and FDG-PET were obtained regarding CT type, adjuvant therapy, and the primary tumor characteristics. The FDG maximum standardized uptake value (SUVmax) was analyzed. The sensitivities of the three modalities (CT, BS, and FDG-PET) were 77, 89, and 94%, respectively. The sensitivity of FDG-PET for the osteoblastic type (69%) was significantly lower than that for the other types (P < 0.001), and the sensitivity of BS for the negative type (70%) was significantly lower than that for the others. Regarding tumor characteristics, the sensitivity of FDG-PET significantly differed between nuclear grade (NG)1 and NG2-3 (P = 0.032). The SUVmax of the osteoblastic type was significantly lower than that of the other types (P = 0.009). The SUVmax of NG1 was also significantly lower than that of NG2-3 (P = 0.011). No significant difference in FDG uptake (SUVmax) was detected between different histological types. Although FDG-PET is superior to BS for the detection of bone metastases from breast cancer, this technique has limitations in depicting osteoblastic bone metastases and NG1.

  3. Improved accuracy of quantitative parameter estimates in dynamic contrast-enhanced CT study with low temporal resolution

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Mo, E-mail: Sunmo.Kim@rmp.uhn.on.ca [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Haider, Masoom A. [Department of Medical Imaging, Sunnybrook Health Sciences Centre, Toronto, Ontario M4N 3M5, Canada and Department of Medical Imaging, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Jaffray, David A. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada); Yeung, Ivan W. T. [Radiation Medicine Program, Princess Margaret Hospital/University Health Network, Toronto, Ontario M5G 2M9 (Canada); Department of Medical Physics, Stronach Regional Cancer Centre, Southlake Regional Health Centre, Newmarket, Ontario L3Y 2P9 (Canada); Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5G 2M9 (Canada)

    2016-01-15

    Purpose: A previously proposed method to reduce radiation dose to patient in dynamic contrast-enhanced (DCE) CT is enhanced by principal component analysis (PCA) filtering which improves the signal-to-noise ratio (SNR) of time-concentration curves in the DCE-CT study. The efficacy of the combined method to maintain the accuracy of kinetic parameter estimates at low temporal resolution is investigated with pixel-by-pixel kinetic analysis of DCE-CT data. Methods: The method is based on DCE-CT scanning performed with low temporal resolution to reduce the radiation dose to the patient. The arterial input function (AIF) with high temporal resolution can be generated with a coarsely sampled AIF through a previously published method of AIF estimation. To increase the SNR of time-concentration curves (tissue curves), first, a region-of-interest is segmented into squares composed of 3 × 3 pixels in size. Subsequently, the PCA filtering combined with a fraction of residual information criterion is applied to all the segmented squares for further improvement of their SNRs. The proposed method was applied to each DCE-CT data set of a cohort of 14 patients at varying levels of down-sampling. The kinetic analyses using the modified Tofts’ model and singular value decomposition method, then, were carried out for each of the down-sampling schemes between the intervals from 2 to 15 s. The results were compared with analyses done with the measured data in high temporal resolution (i.e., original scanning frequency) as the reference. Results: The patients’ AIFs were estimated to high accuracy based on the 11 orthonormal bases of arterial impulse responses established in the previous paper. In addition, noise in the images was effectively reduced by using five principal components of the tissue curves for filtering. Kinetic analyses using the proposed method showed superior results compared to those with down-sampling alone; they were able to maintain the accuracy in the

  4. Analysis of metastatic involvement in bone using anatomical and functional information from 18F-FDG PET/CT.

    Science.gov (United States)

    Demirkaya, Omer; AlQahtani, Mohammed; Alsugair, Abdulaziz; Aras, Omer; Abouzied, Mohei-Eldin

    2017-09-01

    Although the overall incidence of bone metastasis is not known, over one-half of the people who die of cancer in the USA every year are thought to have bone involvement. In this study we have developed a method to quantify the metabolic and anatomic changes induced by different types of bone metastases in cancer patients using PET/CT images. Seventy-three cancer patients with no previous history of chemotherapy or radiotherapy who had definite bone metastases documented by PET/CT and other conventional modalities were selected for this study. PET and computed tomography (CT) images were resampled to the same pixel size. Thereafter, the bone structure was segmented using thresholding. The 50% of the maximum standardized uptake value within the bone mask was used to identify bone lesions in each slice. Using the final regions of interest defined at 70% of the maximum, the lesion characteristics including the mean Hounsfield Units were computed from the PET/CT images. The lesions were subjected to visual confirmation by an experienced physician who also categorized them on the basis of the appearances in CT as lytic, sclerotic, mixed, or no-change type. The lesion characteristics were compared using statistical methods. In all, 340 bony lesions in 73 patients with different cancer types were analyzed. The lesions were further categorized into four groups on the basis of their anatomical location. The spine hosts the largest number of lesions. The lumbar bones are the most preferential sites within the spine. Statistical comparison of CT values indicated that the difference between no-change and lytic types was significant. Uptake period did not seem to have a significant impact on no-change and sclerotic types. Quantitatively, maximum standardized uptake value for lytic, no change, mixed, and sclerotic lesions were 7.4, 6.1, 8.2, and 7.2, respectively. A quantitative method provides a convenient way that may serve as a useful tool in monitoring and assessing the

  5. Multifoci Bone Tuberculosis and Lymphadenitis in Mediastinum Mimics Malignancy on FDG-PET/CT: A Case Report

    Directory of Open Access Journals (Sweden)

    Nalan Alan Selçuk

    2014-02-01

    Full Text Available Positron Emission Tomography with 2-deoxy-[F-18]-fluoro-D-glucose (FDG-PET has become a reliable diagnostic tool in clinical practice similar to Magnetic Resonance (MR imaging and Computed Tomography (CT. FDG-PET has especially been used to differentiate malignant from benign lesions, and for staging and follow- up malignant tumors. However, FDG-PET has some pitfalls in cancer screening and FDG tracer accumulates at sites of infection and inflammation. Bone tuberculosis may be confused with malignant tumors of bone and its metastases, and can accumulate focally increased FDG in active period. We present a 60-year-old woman with lytic bone lesions and mediastinal hypermetabolic foci, initially suspected to be malignant by means of FDG-PET and the other imaging modalities; however, bone biopsy confirmed the diagnosis of bone tuberculosis

  6. CT-guided bone biopsy: Initial experience with a commercially available hand held Black and Decker{sup TM} drill

    Energy Technology Data Exchange (ETDEWEB)

    Buckley, O. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Benfayed, W. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Geoghegan, T. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland); Al-Ismail, K. [Department of Radiology, King Faisal Hospital (Saudi Arabia); Munk, P.L. [Department of Radiology, Musculo-Skeletal division, Vancouver General Hospital, 899 W. 12th Ave., Vancouver, BC V5Z 1M9 (Canada); Torreggiani, William C. [Department of Radiology, Adelaide and Meath, Hospital, Tallaght, Dublin 24 (Ireland)]. E-mail: william.torreggiani@amnch.ie

    2007-01-15

    Purpose: To describe the use of a simple commercially available Black and Decker{sup TM} hand based drill in performing CT-guided bone biopsies. Materials and methods: Three international institutions were enrolled in the study. In each centre, a fellowship trained musculoskeletal radiologist directed the assessment of a hand based commercial drill for performing CT-guided bone biopsies. A specially designed component was engineered which allowed the connection of a standard bone biopsy set to a commercial drill. The component was distributed to the three centres involved. Over a 3-year period, data from all three institutions was collected. Information regarding technical success, diagnostic data and complication rates were all collated to assess the technical feasibility of this technique. Results: In total 68 patients underwent bone biopsy using a hand held commercial drill. Technical success was achieved in 65 patients. Diagnostic material was obtained in 53 patients. Non-diagnostic material was obtained in 12 patients. Five out of the 12 patients with non-diagnostic material had repeat biopsies with diagnostic material obtained in 2 of these. No major complications occurred in any patient. Conclusion: CT-guided bone biopsy using a hand held commercial drill has a technically high success rate with minimal complications.

  7. From histology to micro-CT: Measuring and modeling resorption cavities and their relation to bone competence.

    Science.gov (United States)

    Vanderoost, Jef; van Lenthe, G Harry

    2014-09-28

    The process of bone remodelling plays an essential role in the emergence and maintenance of bone geometry and its internal structure. Osteoclasts are one of the three main bone cell types that play a crucial role in the bone remodelling cycle. At the microstructural level, osteoclasts create bone deficits by eroding resorption cavities. Understanding how these cavities impair the mechanical quality of the bone is not only relevant in quantifying the impact of resorption cavities in healthy bone and normal aging, but maybe even more so in quantifying their role in metabolic bone diseases. Metabolic bone diseases and their treatment are both known to affect the bone remodelling cycle; hence, the bone mechanical competence can and will be affected. However, the current knowledge of the precise dimensions of these cavities and their effect on bone competence is rather limited. This is not surprising considering the difficulties in deriving three-dimensional (3D) properties from two-dimensional (2D) histological sections. The measurement difficulties are reflected in the evaluation of how resorption cavities affect bone competence. Although detailed 3D models are generally being used to quantify the mechanical impact of the cavities, the representation of the cavities themselves has basically been limited to simplified shapes and averaged cavity properties. Qualitatively, these models indicate that cavity size and location are important, and that the effect of cavities is larger than can be expected from simple bone loss. In summary, the dimensions of osteoclast resorption cavities were until recently estimated from 2D measures; hence, a careful interpretation of resorption cavity dimensions is necessary. More effort needs to go into correctly quantifying resorption cavities using modern 3D imaging techniques like micro-computed tomography (micro-CT) and synchrotron radiation CT. Osteoclast resorption cavities affect bone competence. The structure-function relationships

  8. Additional Detection of Multiple Osteomas in a Patient with Gardner's Syndrome by Bone SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Woo Hyoung; Kim, Daeweung; Kim, Chang Guhn; Kim, Myoung Hyoun [Wonkwang Univ. School of Medicine, Iksan (Korea, Republic of)

    2013-12-15

    Familial adenomatous polyposis (FAP) is an autosomal dominant disorder which generally develops numerous polyps in the colon and rectum during the second decade of life. Gardner's syndrome is a variant of FAP which has multiple osteomas, dental abnormalities, and fibromas, with incidence ranging between 1 in 4,000 and 1 in 40,000, depending on the region. We present the case of a 35-year-old man referred to our department for bone scintigraphy who was shown to have multiple colon polyps and nuchal type fibroma. In this patient, planar image showed intensely increased uptakes of bone agent in the maxilla and mandible, which are typical findings of Gardner's syndrome. Single photon emission computed tomography/computed tomography (SPECT/CT) was acquired to accurately identify and locate abnormal uptakes detected on planar images. SPECT/CT showed numerous osteomas in the maxilla and mandible where intense uptakes of bone agent were seen. Mildly asymmetrical, focally increased uptake in the superomedial aspect of the left orbit on anterior planar image was shown to be a fontal sinus osteoma on SPECT/CT. Enhanced sensitivity of detecting lesions of SPECT/CT superior to planar scintigraphy has been reported in previous studies. In this report, additional osteomas of sphenoidal and ethmoidal sinuses, which were not seen on planar scintigraphy, were detected by SPECT/CT. This case emphasizes that nuclear physicians should be aware of the typical findings of bone scintigraphy for Gardner's syndrome and also that SPECT/CT could be helpful to diagnose additional lesions not seen on planar images.

  9. Two and three-dimensional morphometric analysis of trabecular bone using X-ray microtomography (μCT)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Alessandro Marcio Hakme da; Silva, Orivaldo Lopes da; Silva Junior, Nelson Ferreira da, E-mail: alhakme@sc.usp.br [Universidade de Sao Paulo (EESC/FMRP/IQSC/USP), Sao Carlos, SP (Brazil); Alves, Jose Marcos [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Escola de Engenharia. Departamento de Engenharia Eletrica e Computacao

    2014-07-01

    Introduction: trabecular bones have a porous microstructure and can be modeled as linear elastic solids, heterogeneous and anisotropic. In the literature, few investigations have compared the two- dimensional (2D) and three-dimensional (3D) morphometric analyses of cancellous bone. Methods: In this investigation eighteen cylindrical samples of cancellous bone (10 mm of diameter and 20 mm of height) were obtained from six bovine head femurs, with similar values for the weight and age, of the same race and gender. The samples were harvested and freeze at - 20 °C before carrying out the micro CT analysis. The CT-Analyzer software was used to measure in three directions (superior-inferior, lateral-medial and anterior-posterior) parameters such as trabecular thickness, trabecular separation, trabecular number and the eigenvalues of the fabric tensor (M). Results: the Comparison of 2D and 3D analyses for the parameters: 2D (plate model) trabecular thickness, trabecular separation and trabecular number were statistically different (p = 0) showing that measurements are not similar to the 3D ones. However, 2D (rod model) trabecular thickness and 3D trabecular thickness measurements presented no significant difference (p = 0.26). The eigenvalues show that the bovine trabecular microstructure has a tendency to transversally isotropic symmetry. Discussion: The method proved to be quite interesting for the characterization of the bone structure through 3D measurements of trabecular bone morphometric parameters in the three possible directions of loading. The results show that x-ray microtomography (μCT) is a technique of great potential for characterization and generating bone quality parameters for the diagnosis of bone metabolism diseases. (author)

  10. Contralateral Cochlear Labyrinthine Concussion without Temporal Bone Fracture: Unusual Posttraumatic Consequence

    Science.gov (United States)

    Méndez, D.; Silva, J. M. Duque; del Álamo, P. Ortega

    2016-01-01

    Introduction. Labyrinthine concussion is a term used to describe a rare cause of sensorineural hearing loss with or without vestibular symptoms occurring after head trauma. Isolated damage to the inner ear without involving the vestibular organ would be designated as a cochlear labyrinthine concussion. Hearing loss is not a rare finding in head trauma that involves petrous bone fractures. Nevertheless it generally occurs ipsilateral to the side of the head injury and extraordinarily in the contralateral side and moreover without the presence of a fracture. Case Report. The present case describes a 37-year-old patient with sensorineural hearing loss and tinnitus in his right ear after a blunt head trauma of the left-sided temporal bone (contralateral). Otoscopy and radiological images showed no fractures or any abnormalities. A severe sensorineural hearing loss was found in his right ear with a normal hearing of the left side. Conclusion. The temporal bone trauma requires a complete diagnostic battery which includes a neurotologic examination and a high resolution computed tomography scan in the first place. Hearing loss after a head injury extraordinarily occurs in the contralateral side of the trauma as what happened in our case. In addition, the absence of fractures makes this phenomenon even more unusual.

  11. From histology to micro-CT:Measuring and modeling resorption cavities and their relation to bone competence

    Institute of Scientific and Technical Information of China (English)

    Jef; Vanderoost; G; Harry; van; Lenthe

    2014-01-01

    The process of bone remodelling plays an essential role in the emergence and maintenance of bone geometry and its internal structure.Osteoclasts are one of the three main bone cell types that play a crucial role in the bone remodelling cycle.At the microstructural level,osteoclasts create bone deficits by eroding resorption cavities.Understanding how these cavities impair the mechanical quality of the bone is not only relevant in quantifying the impact of resorption cavities in healthy bone and normal aging,but maybe even more so in quantifying their role in metabolic bone diseases.Meta-bolic bone diseases and their treatment are both known to affect the bone remodelling cycle;hence,the bone mechanical competence can and will be affected.How-ever,the current knowledge of the precise dimensions of these cavities and their effect on bone competence is rather limited.This is not surprising considering the difficulties in deriving three-dimensional(3D)properties from two-dimensional(2D)histological sections.The measurement difficulties are reflected in the evalua-tion of how resorption cavities affect bone competence.Although detailed 3D models are generally being used to quantify the mechanical impact of the cavities,the representation of the cavities themselves has basicallybeen limited to simplified shapes and averaged cavityproperties.Qualitatively,these models indicate that cav-ity size and location are important,and that the effectof cavities is larger than can be expected from simplebone loss.In summary,the dimensions of osteoclastresorption cavities were until recently estimated from2D measures;hence,a careful interpretation of resorp-tion cavity dimensions is necessary.More effort needsto go into correctly quantifying resorption cavities usingmodern 3D imaging techniques like micro-computedtomography(micro-CT)and synchrotron radiation CT.Osteoclast resorption cavities affect bone competence.The structure-function relationships have been ana-lysed using

  12. Allogeneic cell transplant expands bone marrow distribution by colonizing previously abandoned areas: an FDG PET/CT analysis.

    Science.gov (United States)

    Fiz, Francesco; Marini, Cecilia; Campi, Cristina; Massone, Anna Maria; Podestà, Marina; Bottoni, Gianluca; Piva, Roberta; Bongioanni, Francesca; Bacigalupo, Andrea; Piana, Michele; Sambuceti, Gianmario; Frassoni, Francesco

    2015-06-25

    Mechanisms of hematopoietic reconstitution after bone marrow (BM) transplantation remain largely unknown. We applied a computational quantification software application to hybrid 18F-fluorodeoxyglucose positron emission tomography (PET)/computed tomography (CT) images to assess activity and distribution of the hematopoietic system throughout the whole skeleton of recently transplanted patients. Thirty-four patients underwent PET/CT 30 days after either adult stem cell transplantation (allogeneic cell transplantation [ACT]; n = 18) or cord blood transplantation (CBT; n = 16). Our software automatically recognized compact bone volume and trabecular bone volume (IBV) in CT slices. Within IBV, coregistered PET data were extracted to identify the active BM (ABM) from the inactive tissue. Patients were compared with 34 matched controls chosen among a published normalcy database. Whole body ABM increased in ACT and CBT when compared with controls (12.4 ± 3 and 12.8 ± 6.8 vs 8.1 ± 2.6 mL/kg of ideal body weight [IBW], P bones, ABM increased three- and sixfold in CBT and ACT, respectively, compared with controls (0.9 ± 0.9 and 1.7 ± 2.5 vs 0.3 ± 0.3 mL/kg IBW, P transplanted BM into previously abandoned BM sites.

  13. [{sup 11}C]Choline PET/CT detection of bone metastases in patients with PSA progression after primary treatment for prostate cancer: comparison with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Picchio, Maria [San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); National Research Council (IBFM-CNR), Institute for Bioimaging and Molecular Physiology, Milan (Italy); Spinapolice, Elena Giulia; Crivellaro, Cinzia [University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); Fallanca, Federico; Gianolli, Luigi [San Raffaele Scientific Institute, Nuclear Medicine Department, Milan (Italy); Giovacchini, Giampiero [University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); University Hospital Basel, Institute of Nuclear Medicine, Basel (Switzerland); Messa, Cristina [National Research Council (IBFM-CNR), Institute for Bioimaging and Molecular Physiology, Milan (Italy); University of Milano-Bicocca, Center for Molecular Bioimaging, Milan (Italy); San Gerardo Hospital, Department of Nuclear Medicine, Monza (Italy)

    2012-01-15

    The aim of this study was to evaluate the clinical usefulness of [{sup 11}C]choline positron emission tomography (PET)/CT in comparison with bone scintigraphy (BS) in detecting bone metastases (BM) of patients with biochemical progression after radical treatment for prostate cancer (PCa). Seventy-eight consecutive patients with biochemical progression of PCa (mean prostate-specific antigen 21.1 ng/ml, range 0.2-500.0 ng/ml) referred for both [{sup 11}C]choline PET/CT and BS for restaging purposes were retrospectively analysed. The diagnostic accuracy of [{sup 11}C]choline PET/CT and BS was assessed by using morphological imaging and/or follow-up as standards of reference. As equivocal findings were found, the accuracy analysis was performed twice, once including them as positive and once as negative. A separate analysis was also performed in hormone-resistant patients and data compared with those of patients who did not receive anti-androgenic treatment. Equivocal findings occurred in 1 of 78 (1%) cases in [{sup 11}C]choline PET/CT and in 21 of 78 (27%) cases in BS. Depending on their attribution as either positive or negative, the ranges of sensitivity, specificity, positive predictive value, negative predictive value and accuracy for [{sup 11}C]choline PET/CT were 89-89%, 98-100%, 96-100%, 94-96% and 95-96%, respectively. For BS they were 100-70%, 75-100%, 68-100%, 100-86% and 83-90%, respectively. Concordant findings between [{sup 11}C]choline PET/CT and BS occurred in 55 of 78 (71%) cases. The accuracy of [{sup 11}C]choline PET/CT did not significantly (p = 0.30) differ between hormone-resistant patients (97%) and those who did not receive anti-androgenic treatment (95%). In clinical practice, [{sup 11}C]choline PET/CT may not replace BS because of its lower sensitivity. However, for its high specificity, [{sup 11}C]choline PET/CT positive findings may accurately predict the presence of BM. Equivocal findings are more frequent in BS than [{sup 11}C]choline PET/CT

  14. Distributional variations in trabecular architecture of the mandibular bone: an in vivo micro-CT analysis in rats.

    Directory of Open Access Journals (Sweden)

    Zhongshuang Liu

    Full Text Available To evaluate the effect of trabecular thickness and trabecular separation on modulating the trabecular architecture of the mandibular bone in ovariectomized rats.Fourteen 12-week-old adult female Wistar rats were divided into an ovariectomy group (OVX and a sham-ovariectomy group (sham. Five months after the surgery, the mandibles from 14 rats (seven OVX and seven sham were analyzed by micro-CT. Images of inter-radicular alveolar bone of the mandibular first molars underwent three-dimensional reconstruction and were analyzed.Compared to the sham group, trabecular thickness in OVX alveolar bone decreased by 27% (P = 0.012, but trabecular separation in OVX alveolar bone increased by 59% (P = 0.005. A thickness and separation map showed that trabeculae of less than 100 μm increased by 46%, whereas trabeculae of more than 200 μm decreased by more than 40% in the OVX group compared to those in the sham group. Furthermore, the OVX separation of those trabecular of more than 200 μm was 65% higher compared to the sham group. Bone mineral density (P = 0.028 and bone volume fraction (p = 0.001 were also significantly decreased in the OVX group compared to the sham group.Ovariectomy-induced bone loss in mandibular bone may be related to the distributional variations in trabecular thickness and separation which profoundly impact the modulation of the trabecular architecture.

  15. The effect of L-PRF membranes on bone healing in rabbit tibiae bone defects: micro-CT and biomarker results.

    Science.gov (United States)

    Faot, Fernanda; Deprez, Sanne; Vandamme, Katleen; Camargos, Germana V; Pinto, Nelson; Wouters, Jasper; van den Oord, Joost; Quirynen, Marc; Duyck, Joke

    2017-04-12

    More insight into the biological fundamentals of leukocyte platelet-rich fibrin (L-PRF) guided healing is necessary to recommend its application, in particular in deficient bone sites that need to support implants. This study investigated the short-term bone healing effect of L-PRF treatment in cylindrical non-critical sized bone defects with 3 mm diameter and 6 mm depth in tibiae of 18 adult male New Zealand White rabbits. After a randomization process, 96 bone defects were prepared and half of them were filled with a L-PRF membrane, while untreated defects in the opposite tibia served as control group. The rabbits were euthanized after 7, 14 or 28 days of healing. The bone healing of the cortical and medullary areas was investigated by micro-CT, while the expression of molecular markers (RUNX2, VEGFA, COL1A2 and BMP2) was assessed by qRT-PCR. Treatment with L-PRF did not affect the micro-structural bone characteristics of the repaired bone tissue, except for a decrease in the trabecular connectivity at the cortical level after 14 days of healing. At this time, RUNX2 and VEGFA mRNA levels were significantly lower in the treated defects. L-PRF membranes thus had a temporary negative influence on the bone microarchitecture (Tb.Pf) and on the RUNX2 and VEGFA expression during early bone healing. Overall, L-PRF treatment did not enhance bone regeneration in these non-critical size defects after 28 days.

  16. C-arm cone beam CT perfusion imaging using the SMART-RECON algorithm to improve temporal sampling density and temporal resolution

    Science.gov (United States)

    Li, Yinsheng; Niu, Kai; Li, Ke; Schafer, Sebastian; Royalty, Kevin; Strother, Charles; Chen, Guang-Hong

    2016-03-01

    In this work, a newly developed reconstruction algorithm, Synchronized MultiArtifact Reduction with Tomographic RECONstruction (SMART-RECON), was applied to C-arm cone beam CT perfusion (CBCTP) imaging. This algorithm contains a special rank regularizer, designed to reduce limited-view artifacts associated with super- short scan reconstructions. As a result, high temporal sampling and temporal resolution image reconstructions were achieved using an interventional C-arm x-ray system. The algorithm was evaluated in terms of the fidelity of the dynamic contrast update curves and the accuracy of perfusion parameters through numerical simulation studies. Results shows that, not only were the dynamic curves accurately recovered (relative root mean square error ∈ [3%, 5%] compared with [13%, 22%] for FBP), but also the noise in the final perfusion maps was dramatically reduced. Compared with filtered backprojection, SMART-RECON generated CBCTP maps with much improved capability in differentiating lesions with perfusion deficits from the surrounding healthy brain tissues.

  17. The role of bone SPECT/CT in the evaluation of lumbar spinal fusion with metallic fixation devices

    DEFF Research Database (Denmark)

    Damgaard, Morten; Nimb, Lars; Madsen, Jan L

    2010-01-01

    PURPOSE: It is difficult to evaluate the stability of the lumbar spondylodesis with metallic fixation devices by conventional imaging methods such as radiography or magnetic resonance imaging. It is unknown whether single photon emission computed tomography/computed tomography (SPECT/CT) may...... be useful to detect a lack of fixation of the pedicle screws and hence to predict instability of the fused vertebral segments. MATERIALS AND METHODS: A retrospective analysis of 9 patients who were referred to bone scintigraphy, including combined SPECT/CT, due to persistent pain or discomfort after...

  18. Optimized Temporal Window for Detection and Characterization of Renal Cell Carcinomas with Dynamic CT Scanning

    Institute of Scientific and Technical Information of China (English)

    Jinhong Wang; Peijun Wang; Xiaohu Zhao; Xinqin Mao; Xiaolong Gao; Jun Liu

    2005-01-01

    OBJECTIVE To investigate the optimized time period for detection and characterization of renal cell carcinomas (RCC) when the specific CT features appear during spiral dynamic CT scanning, and to optimize an effective scanning protocol of spiral CT for evaluating RCC.METHODS Twenty-four patients with RCC verified by pathology had undergone a dynamic CT (D-CT) scan. A plain scan was employed to select the target slice. Single-level dynamic scanning started at 14-17 s after the intravenous contrast media had been administered, with a scan interval of 4.9 s acquiring a total number of 17~24 frames. A regular CT scan of the whole kidney followed by a delayed single slice acquisition through the target slice in the excretory phase was performed. Images were assessed in two ways: (1) A group of experienced radiologists reviewed the CT images to find when the specific signs appeared and when the CT features of RCC were optimally displayed; (2) Data measurement of the time-density curves (T-DC) of RCC. The exact time was obtained when the densities of the tumor, renal parenchyma, medulla and aorta reached their peak enhancement, thus also the time when the density difference between tumor and parenchyma was at maximum (Max T-M). Based on the slope of the contrast media uptake curve, T-DC types were ranked from the smallest to the biggest of slope as type A, B and C.RESULTS 1. The review of the CT images by the radiologists showed that the CT features of RCC were optimally demonstrated at 70.2 s. The earliest time at which RCC CT features were examined was at 23.9 s. 2. Image data analysis: the time that the density (or CT value) of the tumor mass reached peak enhancement was at 54 s and peak value was at 80.4 Hu for RCC. The time of the maximal difference of densities between tumor and renal parenchyma was at 102 s.CONCLUSION The following proposal is the scanning protocol for detecting RCC recommended by our research: After a plain scan to determine the target level, a

  19. The temporal bones from Sima de los Huesos Middle Pleistocene site (Sierra de Atapuerca, Spain). A phylogenetic approach.

    Science.gov (United States)

    Martínez, I; Arsuaga, J L

    1997-01-01

    Three well-preserved crania and 22 temporal bones were recovered from the Sima de los Huesos Middle Pleistocene site up to and including the 1994 field season. This is the largest sample of hominid temporal bones known from a single Middle Pleistocene site and it offers the chance to characterize the temporal bone morphology of an European Middle Pleistocene population and to study the phylogenetic relationships of the SH sample with other Upper and Middle Pleistocene hominids. We have carried out a cladistic analysis based on nine traits commonly used in phylogenetic analysis of Middle and Late Pleistocene hominids: shape of the temporal squama superior border, articular eminence morphology, contribution of the sphenoid bone to the median glenoid wall, postglenoid process projection, tympanic plate orientation, presence of the styloid process, mastoid process projection, digastric groove morphology and anterior mastoid tubercle. We have found two autapomorphies on the Home erectus temporal bone: strong reduction of the postglenoid process and absence of the styloid process. Modern humans, Neandertals and the Middle Pleistocene fossils from Europe and Africa constitute a clade characterized by a convex superior border of the temporal squama. The European Middle Pleistocene fossils from Sima de los Huesos, Petralona, Steinheim, Bilzingsleben and Castel di Guido share a Neandertal apomorphy: a relatively flat articular eminence. The fossils from Ehringsdorf, La Chaise Suardi and Biache-Saint-Vaast also display another Neandertal derived trait: an anteriorly obliterated digastric groove. Modern humans and the African Middle Pleistocene fossils share a synapomorphy: a sagittally orientated tympanic plate.

  20. Evaluation of haptic interfaces for simulation of drill vibration in virtual temporal bone surgery.

    Science.gov (United States)

    Ghasemloonia, Ahmad; Baxandall, Shalese; Zareinia, Kourosh; Lui, Justin T; Dort, Joseph C; Sutherland, Garnette R; Chan, Sonny

    2016-11-01

    Surgical training is evolving from an observership model towards a new paradigm that includes virtual-reality (VR) simulation. In otolaryngology, temporal bone dissection has become intimately linked with VR simulation as the complexity of anatomy demands a high level of surgeon aptitude and confidence. While an adequate 3D visualization of the surgical site is available in current simulators, the force feedback rendered during haptic interaction does not convey vibrations. This lack of vibration rendering limits the simulation fidelity of a surgical drill such as that used in temporal bone dissection. In order to develop an immersive simulation platform capable of haptic force and vibration feedback, the efficacy of hand controllers for rendering vibration in different drilling circumstances needs to be investigated. In this study, the vibration rendering ability of four different haptic hand controllers were analyzed and compared to find the best commercial haptic hand controller. A test-rig was developed to record vibrations encountered during temporal bone dissection and a software was written to render the recorded signals without adding hardware to the system. An accelerometer mounted on the end-effector of each device recorded the rendered vibration signals. The newly recorded vibration signal was compared with the input signal in both time and frequency domains by coherence and cross correlation analyses to quantitatively measure the fidelity of these devices in terms of rendering vibrotactile drilling feedback in different drilling conditions. This method can be used to assess the vibration rendering ability in VR simulation systems and selection of ideal haptic devices.

  1. Vestibular system changes in sudden deafness with and without vertigo: a human temporal bone study.

    Science.gov (United States)

    Inagaki, Taro; Cureoglu, Sebahattin; Morita, Norimasa; Terao, Kyoichi; Sato, Teruyuki; Suzuki, Mamoru; Paparella, Michael M

    2012-09-01

    To investigate the vestibular system changes in sudden deafness with vertigo (SDwV) and sudden deafness without vertigo (SDwoV) and the cause of persistent canal paresis (CP) in SDwV patients. Retrospective study. Four temporal bones from the affected ear in 4 patients with unilateral sudden deafness (SD), 2 SDwV and 2 SDwoV, were selected. Four contralateral temporal bones with normal-hearing ears were defined as the control. Morphologic findings of the labyrinth, the number of Scarpa's ganglion cells, and the density of vestibular hair cells were investigated in all temporal bones. Clinical data and the results of vestibular tests of 11 patients with unilateral SD, as a separate group, also were investigated. Atrophic change of the organ of Corti, tectorial membrane, and stria vascularis in cochlea, and deposits and atrophic otoconial membrane in vestibular sense organs were seen on affected ears more than control ears. The density of Type I hair cells seemed to decrease on the saccular macula and the posterior semicircular canal crista on affected ears, and there was no remarkable difference between SDwV and SDwoV. In 1 patient with SDwoV who died 10 months after the onset of SD, there were large amount of deposits on the cupula, the atrophied otoconial membrane was peeling off from the saccular macula, and the saccular membrane collapsed to the saccular macula in the affected ear. In the clinical data, all SDwV who were examined within 2 years from the onset had CP, and all SDwV had profound hearing loss. There is no remarkable difference between SDwV and SDwoV in the number of Scarpa's ganglion cells and the density of vestibular hair cells. The damage of the extracellular superstructure is seen in SD with or without vertigo. The damage of extracellular superstructure is potentially one of the causes of persistent CP in patients with SD.

  2. PET/CT Scanner and Bone Marrow Biopsy in Detection of Bone Marrow Involvement in Diffuse Large B-Cell Lymphoma

    Science.gov (United States)

    El Karak, Fadi; Bou-Orm, Ibrahim R.; Ghosn, Marwan; Kattan, Joseph; Farhat, Fadi; Ibrahim, Toni; Jreige, Mario; El Cheikh, Jean

    2017-01-01

    Evaluation of bone marrow involvement (BMI) is paramount in diffuse large B-cell lymphoma (DLBCL) for prognostic and therapeutic reasons. PET/CT scanner (PET) is now a routine examination for the staging of DLBCL with prognostic and therapeutic implications. This study evaluates the role of PET for detecting marrow involvement compared to bone marrow biopsy (BMB). This monocentric study included 54 patients diagnosed with DLBCL between 2009 and 2013 and who had FDG PET/CT in a pre-treatment setting. A correlation analysis of the detection of BMI by PET and BMB was performed. A prognostic evaluation of BMI by BMB and/or PET/CT and correlation with an overall 2-year survival were analyzed. PET was more sensitive for the detection of BMI than BMB (92.3% vs. 38.5%). It can be considered a discriminatory Pre-BMB test with a negative predictive value of 97.6%. In addition, BMI by PET had a prognostic value with strong correlation with progression-free survival (PFS) (HR = 3.81; p = 0.013) and overall survival (OS) (HR = 4.12; p = 0.03) while the BMB had not. PET shows superior performance to the BMB for the detection of marrow involvement in DLBCL. It may be considered as the first line examination of bone marrow instead of the biopsy. PMID:28099514

  3. Treatment of aneurysmal bone cysts by percutaneous CT-guided injection of calcitonin and steroid

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Kattapuram, Susan V.; Huang, Ambrose J.; Simeone, F.J.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital, Department of Radiology Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States)

    2017-01-15

    To determine the efficacy and safety of percutaneous calcitonin and steroid injection in the treatment of aneurysmal bone cysts (ABCs). Our study was IRB-approved and HIPAA-compliant. We reviewed pre- and post-procedural imaging studies and medical records of all CT-guided percutaneous injections of ABCs with calcitonin and steroid performed at our institution between 2003 and 2015. Treatment success based on imaging was categorized as substantial (51-100 %), partial (1-50 %), or none (0 %) by comparing radiographs of the lesion before and after treatment. Our study group comprised 9 patients (7 female, 2 male; mean age 19 ± 5 (range 12-25) years). ABCs were located in the pubis (n = 3), femur (n = 2), and humerus/scapula/ilium/sacrum (n = 1 for each). One patient did not have any clinical or imaging follow-up. For the other 8 patients, clinical and imaging follow-up ranged from 1 to 93 months (mean 16 ± 29 months). One patient had two injections, and 1 patient had three injections. Six out of eight patients (75 %) had complete symptomatic relief and 2 patients (25 %) had partial symptomatic relief after initial injection. Imaging follow-up revealed substantial imaging response in 4 out of 8 patients (50 %). There was a partial imaging response in 2 patients (25 %) and no imaging response in 2 out of 8 patients (25 %), and all 4 of these patients had local recurrence. There were no complications. Percutaneous CT-guided injection of ABCs with calcitonin and steroid is a safe and effective treatment. Lack of imaging response may necessitate more aggressive treatment to minimize local recurrence. (orig.)

  4. Temporal bone histopathology in trisomy 18 syndrome: a report of two cases.

    Directory of Open Access Journals (Sweden)

    Saito,Ryusuke

    1987-06-01

    Full Text Available Temporal bone histopathological findings of two patients with trisomy 18 syndrome are described. Many of the abnormalities previously described were seen in the present cases; namely, atresia of the external auditory canal, aberrant course of the tensor tympani muscle, malformed stapes, aberrant course of the facial nerve with an obtuse angulation at the first genu and displacement of geniculate ganglion cells into the internal auditory canal, shortened cochlea with decreased spiral ganglion cell population, and vestibular anomalies, such as bony and membranous blockage of the superior semicircular canal. Moreover, an extremely underdeveloped malleus and incus continuous with a persistent Meckel's cartilage were observed.

  5. [Glomus tumors of the temporal bone: a report of 6 cases].

    Science.gov (United States)

    Arruda, W O; Teive, H A; Torres, L F; Ramina, R; Parolim, M K; Maniglia, J J; Barrionuevo, C E

    1989-03-01

    The authors review the clinical, radiological and pathological features of 6 cases of glomus tumors of the temporal bone. Out of the 6 patients, 5 were female; age was distributed between 22 and 76 years (mean 48 years). The main clinical features were hypoacusia, tinnitus and otoscopic findings suggestive of the diagnosis. In one case was noted the concomitant presence of a neurinoma of the VIII cranial nerve with a ipsilateral glomus tumor, and in another case there was a concomitancy of carotid body tumor with temporal glomus jugularis tumor. Metastases were not observed in any case. Tumoral lesions were successfully ressected employing microsurgical techniques and a multidisciplinary staff involving neurosurgeons, head and neck surgeons and otolaryngologists. Radioteraphy was not employed, neither pre-operative embolization. Some aspects related to the nosology, embriology, pathophysiology, diagnosis and treatment of this interesting type of neoplasms are discussed.

  6. SPECT/CT in the Diagnosis of Skull Base Osteomyelitis

    Energy Technology Data Exchange (ETDEWEB)

    Damle, Nishikant Avinash; Kumar, Rakesh; Kumar, Praveen; Jaganthan, Sriram; Patnecha, Manish; Bal, Chandrasekhar; Bandopadhyaya, Gurupad; Malhotra, Arun [All India Institute of Medical Sciences, New Delhi (India)

    2011-09-15

    Skull base osteomyelitis is a potentially fatal disease. We demonstrate here the utility of SPECT/CT in diagnosing this entity, which was not obvious on a planar bone scan. A {sup 99mT}c MDP bone scan with SPECT/CT was carried out on a patient with clinically suspected skull base osteomyelitis. Findings were correlated with contrast enhanced CT (CECT) and MRI. Planar images were equivocal, but SPECT/CT showed intense uptake in the body of sphenoid and petrous temporal bone as well as the atlas corresponding to irregular bone destruction on CT and MRI. These findings indicate that SPECT/CT may have an additional role beyond planar imaging in the detection of skull base osteomyelitis.

  7. Direct visualization of regions with lowered bone mineral density in dual-energy CT images of vertebrae

    Science.gov (United States)

    Wesarg, Stefan; Erdt, Marius; Kafchitsas, Konstantinos; Khan, M. Fawad

    2011-03-01

    Dual-energy CT allows for a better material differentiation than conventional CT. For the purpose of osteoporosis diagnosis, a detection of regions with lowered bone mineral density (BMD) is of high clinical interest. Based on an existing biophysical model of the trabecular bone in vertebrae a new method for directly highlighting those low density regions in the image data has been developed. For this, we combine image data acquired at 80 kV and 140 kV with information about the BMD range in different vertebrae and derive a method for computing a color enhanced image which clearly indicates low density regions. An evaluation of our method which compares it with a quantitative method for BMD assessment shows a very good correspondence between both methods. The strength of our method lies in its simplicity and speed.

  8. ''Black Bone'' MRI: a potential alternative to CT with three-dimensional reconstruction of the craniofacial skeleton in the diagnosis of craniosynostosis

    Energy Technology Data Exchange (ETDEWEB)

    Eley, Karen A. [University of Oxford, John Radcliffe Hospital, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); University of Cambridge, Addenbrookes Hospital, Department of Radiology, Cambridge (United Kingdom); Watt-Smith, Stephen R. [University of Oxford, John Radcliffe Hospital, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); University College London, Eastman Dental Institute, London (United Kingdom); Sheerin, Fintan [University of Oxford, John Radcliffe Hospital, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Oxford University Hospitals NHS Trust, Oxford (United Kingdom); Golding, Stephen J. [University of Oxford, John Radcliffe Hospital, Nuffield Department of Surgical Sciences, Oxford (United Kingdom)

    2014-10-15

    To determine the potential of novel gradient echo parameters, ''Black Bone'' MRI as an alternative to CT in the identification of normal and prematurely fused cranial sutures both in 2D and 3D imaging. Thirteen children with a clinical diagnosis of craniosynostosis underwent ''Black Bone'' MRI in addition to routine cranial CT. ''Black Bone'' datasets were compared to CT and clinical findings. ''Black Bone'' imaging was subsequently used to develop 3D reformats of the craniofacial skeleton to enhance further visualisation of the cranial sutures. Patent cranial sutures were consistently identified on ''Black Bone'' MRI as areas of increased signal intensity. In children with craniosynostosis the affected suture was absent, whilst the remaining patent sutures could be visualised, consistent with CT and clinical findings. Segmentation of the ''Black Bone'' MRI datasets was successful with both threshold and volume rendering techniques. The cranial sutures, where patent, could be visualised throughout their path. Patent cranial sutures appear as areas of increased signal intensity on ''Black Bone'' MRI distinct from the cranial bone, demonstrating considerable clinical potential as a non-ionising alternative to CT in the diagnosis of craniosynostosis. (orig.)

  9. Micro-CT examination of human bone: from biopsies towards the entire organ

    Directory of Open Access Journals (Sweden)

    Egon Perilli

    2012-01-01

    Full Text Available Micro-CT systems are available that facilitate ex vivo examinations of human specimens as big as entire vertebrae, with spatial resolutions in the 10-micrometer range. This opens a new way for looking at entire bones in 3D. Accurate description of the internal microarchitecture of the entire organ can be obtained, at spatial resolutions previously achievable only on excised biopsies. These high resolution scans produce large datasets and come with costs and benefits, which have to be considered in the successful planning of an experiment. The aim of this paper is to present examples of human vertebrae scanned at high resolution (17 μm/pixel, allowing the visualization and quantification of the microarchitecture, and to discuss some aspects of using high resolution scans of such large specimens. The datasets were down-sampled to 34 μm and 68 μm pixel size, and their morphometric parameters compared to those obtained at 17 μm pixel size, in relation to data size and calculation time.

  10. Subject-specific bone attenuation correction for brain PET/MR: can ZTE-MRI substitute CT scan accurately?

    Science.gov (United States)

    Khalifé, Maya; Fernandez, Brice; Jaubert, Olivier; Soussan, Michael; Brulon, Vincent; Buvat, Irène; Comtat, Claude

    2017-10-01

    In brain PET/MR applications, accurate attenuation maps are required for accurate PET image quantification. An implemented attenuation correction (AC) method for brain imaging is the single-atlas approach that estimates an AC map from an averaged CT template. As an alternative, we propose to use a zero echo time (ZTE) pulse sequence to segment bone, air and soft tissue. A linear relationship between histogram normalized ZTE intensity and measured CT density in Hounsfield units (HU ) in bone has been established thanks to a CT-MR database of 16 patients. Continuous AC maps were computed based on the segmented ZTE by setting a fixed linear attenuation coefficient (LAC) to air and soft tissue and by using the linear relationship to generate continuous μ values for the bone. Additionally, for the purpose of comparison, four other AC maps were generated: a ZTE derived AC map with a fixed LAC for the bone, an AC map based on the single-atlas approach as provided by the PET/MR manufacturer, a soft-tissue only AC map and, finally, the CT derived attenuation map used as the gold standard (CTAC). All these AC maps were used with different levels of smoothing for PET image reconstruction with and without time-of-flight (TOF). The subject-specific AC map generated by combining ZTE-based segmentation and linear scaling of the normalized ZTE signal into HU was found to be a good substitute for the measured CTAC map in brain PET/MR when used with a Gaussian smoothing kernel of 4~mm corresponding to the PET scanner intrinsic resolution. As expected TOF reduces AC error regardless of the AC method. The continuous ZTE-AC performed better than the other alternative MR derived AC methods, reducing the quantification error between the MRAC corrected PET image and the reference CTAC corrected PET image.

  11. Visual and quantitative approach to bone marrow foci of increased glucose uptake on PET/CT in a case of aplastic anaemia

    Energy Technology Data Exchange (ETDEWEB)

    Cicone, F. [Sant' Andrea Hospital, Univ. La Sapienza, Rome (Italy). Nuclear Medicine Dept.; Centre Hospitalier Univ. Vaudois (Switzerland). Nuclear Medicine; Lausanne Univ. (Switzerland); Stalder, M. [Institut Central des Hopitaux Valaisans, Sion (Switzerland). Service of Hematology; Cairoli, A. [Centre Hospitalier Univ. Vaudois (Switzerland). Service of Hematology; Lausanne Univ. (Switzerland); Bischof Delaloye, A.; Prior, J.O. [Centre Hospitalier Univ. Vaudois (Switzerland). Nuclear Medicine; Lausanne Univ. (Switzerland); Geiger, D.

    2010-07-01

    This case report shows the clinical impact of a FDG-PET/CT in the assessment of bone marrow (BM) of a patient with aplastic anemia. The feasibility of a quantitative approach to BM intensities on FDG-PET is also discussed. In the authors' opinion, a deeper understanding of the factors that might independently affect FDG uptake and the definition of normal ranges of BM SUV (standardized uptake value) might help to interpret PET/CT images. Further research is needed to understand the physio-pathological basis of FDG uptake in BM and the potential value of its quantification. The analysis of the bone marrow on PET/CT is an interesting field of research. A PET/CT scan contributed to differential diagnosis in a patient with suspected bone marrow aplasia for guiding bone marrow biopsies.

  12. Histomorphometric analysis of the temporal bone after change of direction of force vector of mandible: an experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Edela Puricelli

    2012-10-01

    Full Text Available OBJECTIVES: The present study aimed at performing a histological evaluation of the response of temporal bone tissue to a change of direction of the force vector of the mandible in relation to the base of the skull. MATERIAL AND METHODS: Adult rabbits were assigned into four groups with two control and four experimental animals in each group. experimental animals underwent surgery, which resulted in a change of direction of the force vector on the right temporomandibular joint. Samples were collected after 15, 30, 60 and 90 days for histological analysis. RESULTS: In the two-way analysis of variance, the effect of group and time was statistically significant (p<0.001. Additionally, a statistically significant interaction between group and time was observed (p<0.001. Control animals showed normal growth and development of the temporal region. In the experimental group, the change in direction of the force vector of the mandible induced significant changes in the temporal bone, with a bone modeling process, which suggests growth of this cranial structure. CONCLUSIONS: The methodology used in this experiment allows us to conclude that the change in direction of the force vector of the mandible in relation to the skull base induces remodeling and modeling processes in the temporal bone. The resumption of normal oral functions after bone healing of the mandibular fracture appears to increase cell activation in the remodeling and modeling of the temporal bone structure. The observation of areas of temporal bone modeling shows the relevance of further investigation on the correlation between the joint structures and craniofacial growth and development.

  13. Familial dysautonomia (Riley-Day syndrome). Temporal bone findings and otolaryngological manifestations.

    Science.gov (United States)

    Tokita, N; Sekhar, H K; Sachs, M; Daly, J F

    1978-01-01

    Familial dysautonomia, or Riley-Day syndrome, is inherited in an autosomal recessive fashion and occurs almost exclusively in Jewish families. This disorder is characterized by a smooth tongue devoid of fungiform papillae and of taste buds, and is clinically associated with poor taste discrimination. An unsteady gait and dizziness on change in position are also common presenting symptoms. This study reports the histopathological findings of eight temporal bones from four patients with documented familial dysautonomia. For the control series, 13 normal temporal bones were also studied. The most striking finding in the dysautonomic patients was an extreme paucity of geniculate ganglion cells (P less than 0.001). A statistically significant reduction in the number of neurons was also found both in the superior and in the inferior divisions of the vestibular nerve (P less than 0.001). The paucity of the geniculate ganglion cells correlates well with the impairment of the taste in dysautonomic individuals, since the afferent fibers leaving taste buds of the anterior two-thirds of the tongue run via the chorda tympani and have their cell bodies in the geniculate ganglion. Furthermore, the reduction in the number of Scarpa's ganglion cells observed in the dysautonomic patients studied here could account for a poor response to caloric test, positional vertigo and an unsteady gait in this condition.

  14. Extraction of 3D Femur Neck Trabecular Bone Architecture from Clinical CT Images in Osteoporotic Evaluation: a Novel Framework.

    Science.gov (United States)

    Sapthagirivasan, V; Anburajan, M; Janarthanam, S

    2015-08-01

    The early detection of osteoporosis risk enhances the lifespan and quality of life of an individual. A reasonable in-vivo assessment of trabecular bone strength at the proximal femur helps to evaluate the fracture risk and henceforth, to understand the associated structural dynamics on occurrence of osteoporosis. The main aim of our study was to develop a framework to automatically determine the trabecular bone strength from clinical femur CT images and thereby to estimate its correlation with BMD. All the 50 studied south Indian female subjects aged 30 to 80 years underwent CT and DXA measurements at right femur region. Initially, the original CT slices were intensified and active contour model was utilised for the extraction of the neck region. After processing through a novel process called trabecular enrichment approach (TEA), the three dimensional (3D) trabecular features were extracted. The extracted 3D trabecular features, such as volume fraction (VF), solidity of delta points (SDP) and boundness, demonstrated a significant correlation with femoral neck bone mineral density (r = 0.551, r = 0.432, r = 0.552 respectively) at p TEA method would be useful for spotting women vulnerable to osteoporotic risk.

  15. The quantification of glenoid bone loss in anterior shoulder instability; MR-arthro compared to 3D-CT

    Energy Technology Data Exchange (ETDEWEB)

    Markenstein, Jeroen E. [Onze Lieve Vrouwe Gasthuis, Department of Orthopedic Surgery, Postbox 95500, Amsterdam (Netherlands); Jaspars, Kjell C.C.J. [Van Weel-Bethesda Ziekenhuis, Department of Orthopedic Surgery, Dirksland (Netherlands); Hulst, Victor P.M. van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Postbox 95500, Amsterdam (Netherlands); Willems, W.J. [Delairesse Kliniek, Department of Orthopedic Surgery, Amsterdam (Netherlands)

    2014-04-15

    The purpose of this study is to investigate if magnetic resonance imaging with intra-articular contrast (MR-arthro) is as reliable as three-dimensionally reconstructed computed tomography imaging (3D-CT) in quantifying the glenoid bone loss in patients with anterior shoulder instability. Thirty-five patients were included. Sagittal MR-arthro and 3D-CT images of the glenoid surface were obtained pre-operatively. Two observers measured these images twice with OsiriX software in a randomized and blinded way. The intraclass correlations (ICC) of the intra- and inter-observer reliability within one method and an additional Bland-Altman plot for calculating agreement between the two methods were obtained. The joint estimates of the intra-observer reliability, taking into account the data from both observer A and B, for 3D-CT and MR-arthro were good to excellent. The intra-observer reliability was 0.938 (95 % CI: 0.879, 0.968) for 3D-CT and 0.799 (95 % CI: 0.639, 0.837) for MR-arthro. The inter-observer reliability between the two observers within one method (3D-CT or MR-arthro) was moderate to good. 3D-CT: 0.724 (95 % CI: 0.236, 0.886) and MR-arthro: 0.534 (95 % CI: 0.128, 0.762). Comparing both the 3D-CT and MR-arthro method, a Bland-Altman plot showed satisfying differences with the majority of outcomes (89 %) within 1 SD. Good to excellent intra- and moderate to good inter-observer correlations and a satisfying Bland-Altman plot when compared to 3D-CT show tendencies that MR-arthro is reliable and valid for measuring bony defects of the glenoid. (orig.)

  16. Dual energy CT of peripheral arteries: Effect of automatic bone and plaque removal on image quality and grading of stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, B.C. [Charite - University Hospital, Campus Benjamin Franklin, Department of Radiology and Nuclear Medicine, Hindenburgdamm 30, 12200 Berlin (Germany)], E-mail: Bernhard.Meyer@charite.de; Werncke, T. [Charite - University Hospital, Campus Benjamin Franklin, Department of Radiology and Nuclear Medicine, Hindenburgdamm 30, 12200 Berlin (Germany); Hopfenmueller, W. [Charite - University Hospital, Campus Benjamin Franklin, Department of Biometry and Clinical Epidemiology, Hindenburgdamm 30, 12200 Berlin (Germany); Raatschen, H.J.; Wolf, K.-J.; Albrecht, T. [Charite - University Hospital, Campus Benjamin Franklin, Department of Radiology and Nuclear Medicine, Hindenburgdamm 30, 12200 Berlin (Germany)

    2008-12-15

    Purpose: To evaluate the effect of automatic bone and plaque removal on image quality and grading of steno-occlusive lesions in patients undergoing dual energy CT angiography (CTA) of lower extremity. Materials and methods: Dual energy (DE) runoff CTA was performed in 50 patients using the following parameters: collimation 2 x 32 x 0.6; tube potentials, 80 kV and 140 kV; reconstructed slice thickness 1 mm. 100 mL iomeprol 400 and 50 mL saline were injected at 4 mL/s. Separate datasets were calculated for each of the two tubes and used to generate automatically bone-subtracted images (ABS) as well as bone and plaque subtracted images (ABPS). Residual bone in the ABS dataset was removed manually (=ABS-B dataset). In addition, a weighted average dataset from both dual energy acquisitions resembling a routine 120 kV CT acquisition was used for standard manual bone subtraction (MBS). Operator time for bone removal was measured. Effectiveness of bone subtraction and presence of vessel erosions was assessed by two readers in consensus. Stenosis grading in plaque subtracted and unsubtracted images was assessed and correlated. Results: Residual bone fragments (ribs: 46%, patella: 25%, spine: 4%, pelvis: 2%, tibia 2% of patients) were only observed with ABS. The time needed to manually remove these residual bones was 2.1 {+-} 1.1 min and was significantly lower than the duration of manual bone removal (6.8 {+-} 2.0 min, p < 0.0001, paired t-test). A total of 1159 arteries were analyzed. Compromising vessel erosions were observed less frequently in the ABS-B dataset (10.6%) than in the MBS dataset (15.2%, p < 0.001, wilcoxon's signed rank test). A total of 817 steno-occlusive lesions were assessed. While the agreement of grading of steno-occlusive lesions was good at the levels of the aorta and the pelvic arteries ({kappa} = 0.70 in both, Cohen's kappa statistics), it was moderate at the level of the thigh arteries ({kappa} = 0.57) and poor at the level of the calf

  17. Assessment of image quality in soft tissue and bone visualization tasks for a dedicated extremity cone-beam CT system

    Energy Technology Data Exchange (ETDEWEB)

    Demehri, S. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Johns Hopkins Outpatient Center, JHOC 5168, Musculoskeletal Radiology, Baltimore, MD (United States); Muhit, A.; Zbijewski, W.; Stayman, J.W. [Johns Hopkins University, Department of Biomedical Engineering, Baltimore, MD (United States); Yorkston, J.; Packard, N.; Senn, R.; Yang, D.; Foos, D. [Carestream Health, Rochester, NY (United States); Thawait, G.K.; Fayad, L.M.; Chhabra, A.; Carrino, J.A. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Siewerdsen, J.H. [Johns Hopkins University, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States); Johns Hopkins University, Department of Biomedical Engineering, Baltimore, MD (United States)

    2015-06-01

    To assess visualization tasks using cone-beam CT (CBCT) compared to multi-detector CT (MDCT) for musculoskeletal extremity imaging. Ten cadaveric hands and ten knees were examined using a dedicated CBCT prototype and a clinical multi-detector CT using nominal protocols (80kVp-108mAs for CBCT; 120kVp- 300mAs for MDCT). Soft tissue and bone visualization tasks were assessed by four radiologists using five-point satisfaction (for CBCT and MDCT individually) and five-point preference (side-by-side CBCT versus MDCT image quality comparison) rating tests. Ratings were analyzed using Kruskal-Wallis and Wilcoxon signed-rank tests, and observer agreement was assessed using the Kappa-statistic. Knee CBCT images were rated ''excellent'' or ''good'' (median scores 5 and 4) for ''bone'' and ''soft tissue'' visualization tasks. Hand CBCT images were rated ''excellent'' or ''adequate'' (median scores 5 and 3) for ''bone'' and ''soft tissue'' visualization tasks. Preference tests rated CBCT equivalent or superior to MDCT for bone visualization and favoured the MDCT for soft tissue visualization tasks. Intraobserver agreement for CBCT satisfaction tests was fair to almost perfect (κ ∝ 0.26-0.92), and interobserver agreement was fair to moderate (κ ∝ 0.27-0.54). CBCT provided excellent image quality for bone visualization and adequate image quality for soft tissue visualization tasks. (orig.)

  18. Displasia fibrosa do osso temporal: relato de caso e revisão da literatura Fibrous dysplasia of the temporal bone: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Vanier S. Júnior

    2004-12-01

    Full Text Available Displasia fibrosa é uma doença caracterizada por progressiva substituição dos elementos normais do osso por tecido fibroso. É uma patologia benigna incomum de etiologia desconhecida. Existem duas categorias primárias da doença: displasia fibrosa monostótica que envolve somente um osso e displasia fibrosa poliostótica acometendo múltiplos ossos. Embora o esqueleto crânio-facial seja sede freqüente da doença, o osso temporal raramente está envolvido. O envolvimento do osso temporal tem como sintoma mais comum a surdez. O diagnóstico é baseado em imagens radiológicas. Quando a displasia fibrosa é acompanhada por sintomas clínicos significantes, o tratamento cirúrgico é recomendado. O acompanhamento clínico do paciente é fundamental para o diagnóstico precoce de recidivas. Neste artigo relatamos um caso de displasia fibrosa do osso temporal e revisão da patologia na literatura.Fibrous dysplasia is a disease characterized by progressive replacement of normal bone elements by fibrous tissue. It is an uncommon benign disorder of unknown etiology. There are two primary categories of the disease: monostotic fibrous dysplasia that involves a single bone and polyostotic fibrous dysplasia that involves multiple bones. Although the craniofacial skeleton is a common site of the disease, the temporal bone rarely becomes involved. The most common presenting symptom is deafness and diagnosis is based on radiological images. When fibrous dysplasia is accompanied by significant clinical symptoms, surgery is recommended. The follow up of these patients is very important to make early diagnosis of recurrences. In this article we report a case of fibrous dysplasia of the temporal bone and review the literature.

  19. Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshiyuki [National Cardiovascular Center, Department of Radiology, Osaka (Japan); St. Luke' s International Hospital, Department of Radiology, Tokyo (Japan); Uotani, Kensuke; Nakazawa, Tetsuro; Higashi, Masahiro; Yamada, Naoaki; Hori, Yoshiro; Kanzaki, Suzu; Fukuda, Tetsuya; Naito, Hiroaki [National Cardiovascular Center, Department of Radiology, Osaka (Japan); Itoh, Toshihide [Siemens Asahi Medical Technologies, Tokyo (Japan)

    2009-04-15

    Dual-energy CT can be applied for bone elimination in cerebral CT angiography (CTA). The aim of this study was to compare the results of dual-energy direct bone removal CTA (DE-BR-CTA) with those of digital subtraction angiography (DSA). Twelve patients with intracranial aneurysms and/or ICA stenosis underwent a dual-source CT in dual-energy mode. Post-processing software selectively removed bone structures using the two energy data sets. Three-dimensional images with and without bone removal were reviewed and compared to DSA. Dual-energy bone removal was successful in all patients. For 10 patients, bone removal was good and CTA maximum-intensity projection (MIP) images could be used for vessel evaluation. For two patients, bone removal was moderate with some bone remnants, but this did not inhibit the three-dimensional visualization. Three aneurysms adjacent to the skull base were only partially visible in conventional CTA but were fully visible in DE-BR-CTA. In five patients with ICA stenosis, DE-BR-CTA revealed the stenotic lesions on the MIP images. The correlation between DSA and DE-BR-CTA was good (R {sup 2}=0.822), but DE-BR-CTA led to an overestimation of stenosis. DE-BR-CTA was able to eliminate bone structure using only a single CT data acquisition and is useful to evaluate intracranial aneurysms and stenosis. (orig.)

  20. Evaluation study of the sinus lift technique in combination with autologous bone augmentation in dogs' frontal sinus. Limited cone beam CT image and histopathological analyses

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Tatsuo [Tokyo Women' s Medical Coll. (Japan). School of Medicine

    2002-08-01

    The posterior area of the maxilla has often been considered inadequate for the insertion of dental implants due to insufficient height of the alveolar bone by atrophic reduction and the maxillary sinus expansion. This anatomic problem may be resolved with augmentation of the floor of the maxillary sinus. The purpose of this study is to evaluate the effectiveness of sinus lift and grafting with the iliac crest bone performed in the dog frontal sinus as a model of the human maxillary sinus. Time course evaluations of bone volume after insertion of implants were performed by the limited cone beam CT (Ortho-CT), histopathological study and NIH-image digital analysis. New bone formation was identified as early as 2 weeks after the implant insertion. The bone volume was increased continuously until 13th week. High-density bone was found in the cervix of the implant after 26 weeks. However, the bone was lost at apex area of the implant and air cavity of the frontal sinus expanded. Ortho-CT findings showed good correlation with histopathological course of the lesion and bone volume identified by the NIH image analysis. The results revealed first time whole course of the bone remodeling after implant insertion into the frontal sinus of a dog. The data also provide an appropriate timing of the implant prosthesis and promise usefulness of the Ortho-CT in planning efficient implant treatment. (author)

  1. Exploring bone dynamics using in-vivo micro-CT imaging

    NARCIS (Netherlands)

    J.H. Waarsing (Jan)

    2006-01-01

    textabstractBone is an active organ that adapts its shape to the (mechanical) environment. The general mechanisms behind bone adaptation remain largely unknown. In this thesis a new imaging modality for bone research is introduced and used to investigate various aspects of bone adaptation. The

  2. Exploring bone dynamics using in-vivo micro-CT imaging

    NARCIS (Netherlands)

    J.H. Waarsing (Jan)

    2006-01-01

    textabstractBone is an active organ that adapts its shape to the (mechanical) environment. The general mechanisms behind bone adaptation remain largely unknown. In this thesis a new imaging modality for bone research is introduced and used to investigate various aspects of bone adaptation. The topic

  3. Detection of Bone Marrow Edema in Nondisplaced Hip Fractures: Utility of a Virtual Noncalcium Dual-Energy CT Application.

    Science.gov (United States)

    Kellock, Trenton T; Nicolaou, Savvas; Kim, Sandra S Y; Al-Busaidi, Sultan; Louis, Luck J; O'Connell, Tim W; Ouellette, Hugue A; McLaughlin, Patrick D

    2017-09-01

    Purpose To quantify the sensitivity and specificity of dual-energy computed tomographic (CT) virtual noncalcium images in the detection of nondisplaced hip fractures and to assess whether obtaining these images as a complement to bone reconstructions alters sensitivity, specificity, or diagnostic confidence. Materials and Methods The clinical research ethics board approved chart review, and the requirement to obtain informed consent was waived. The authors retrospectively identified 118 patients who presented to a level 1 trauma center emergency department and who underwent dual-energy CT for suspicion of a nondisplaced traumatic hip fracture. Clinical follow-up was the standard of reference. Three radiologists interpreted virtual noncalcium images for traumatic bone marrow edema. Bone reconstructions for the same cases were interpreted alone and then with virtual noncalcium images. Diagnostic confidence was rated on a scale of 1 to 10. McNemar, Fleiss κ, and Wilcoxon signed-rank tests were used for statistical analysis. Results Twenty-two patients had nondisplaced hip fractures and 96 did not have hip fractures. Sensitivity with virtual noncalcium images was 77% and 91% (17 and 20 of 22 patients), and specificity was 92%-99% (89-95 of 96 patients). Sensitivity increased by 4%-5% over that with bone reconstruction images alone for two of the three readers when both bone reconstruction and virtual noncalcium images were used. Specificity remained unchanged (99% and 100%). Diagnostic confidence in the exclusion of fracture was improved with combined bone reconstruction and virtual noncalcium images (median score: 10, 9, and 10 for readers 1, 2, and 3, respectively) compared with bone reconstruction images alone (median score: 9, 8, and 9). Conclusion When used as a supplement to standard bone reconstructions, dual-energy CT virtual noncalcium images increased sensitivity for the detection of nondisplaced traumatic hip fractures and improved diagnostic confidence in

  4. Estimating the whole bone-marrow asset in humans by a computational approach to integrated PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sambuceti, Gianmario [University of Genoa, Nuclear Medicine, Department of Internal Medicine, Genova (Italy); CNR Institute of Bioimages and Molecular Physiology, Genova (Italy); Advanced Biotechnology Center, Genova (Italy); Brignone, Massimo [University of Genoa, Nuclear Medicine, Department of Internal Medicine, Genova (Italy); University of Genoa, Department of Mathematics, Genoa (Italy); Marini, Cecilia [CNR Institute of Bioimages and Molecular Physiology, Genova (Italy); Massollo, Michela; Fiz, Francesco; Morbelli, Silvia; Buschiazzo, Ambra; Piva, Roberta [University of Genoa, Nuclear Medicine, Department of Internal Medicine, Genova (Italy); Campi, Cristina [University of Helsinki, Department of Computer Science, Helsinki (Finland); Massone, Anna Maria [CNR-SPIN, Genova (Italy); Piana, Michele [University of Genoa, Department of Mathematics, Genoa (Italy); CNR-SPIN, Genova (Italy); Frassoni, Francesco [Istituto Giannina Gaslini, Genoa (Italy); Advanced Biotechnology Center, Genova (Italy)

    2012-08-15

    Despite their relevance in clinical medicine, the extension and activity of the bone marrow (BM) cannot be directly evaluated in vivo. We propose a new method to estimate these variables by combining structural and functional maps provided by CT and PET. BM extension and glucose uptake were estimated in 102 patients undergoing whole-body PET/CT because of a history of nonmetastatic melanoma. Image analysis assumed that the BM is surrounded by compact bone. An iterative optimization scheme was applied to each CT slice to identify the external border of the bone. To identify compact bone, the algorithm measured the average Hounsfield coefficient within a two-pixel ring located just inside the bone contour. All intraosseous pixels with an attenuation coefficient lower than this cut-off were flagged as 1, while the remaining pixels were set at 0. Binary masks created from all CT slices were thus applied to the PET data to determine the metabolic activity of the intraosseous volume (IBV). Estimated whole-body IBV was 1,632 {+-} 587 cm{sup 3} and was higher in men than in women (2,004 {+-} 498 cm{sup 3} vs. 1,203 {+-} 354 cm{sup 3}, P < 0.001). Overall, it was strictly correlated with ideal body weight (r = 0.81, P = 0.001) but only loosely with measured body weight (r = 0.43, P = 0.01). The average FDG standardized uptake value (SUV) in the thoracic and lumbar vertebrae was 2.01 {+-} 0.36, Accordingly, intraosseous voxels with SUV {>=}1.11 (mean spine SUV - 2.5 x SD) were considered as active ''red'' BM and those with SUV <1.11 as ''yellow'' BM. Estimated red BM volume was 541 {+-} 195 ml, with a higher prevalence in the axial than in the appendicular skeleton (87 {+-} 8 % vs. 10 {+-} 8 %, P < 0.001). Again, red BM volume was higher in men than in women (7.8 {+-} 2.2 vs. 6.7 {+-} 2.1 ml/kg body weight, P < 0.05), but in women it occupied a greater fraction of the IBV (32 {+-} 7 % vs. 36 {+-} 10 %, P < 0.05). Patient age modestly

  5. Assessment of lumbar trabecular bone density by means of single energy quantitative CT in hospital control children and bone metabolic disorders, 1

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Kazutoshi; Miyamoto, Akie; Imai, Kaoru; Mochizuki, Yumiko; Hayashi, Kitami; Mitsuishi, Yoichi; Fukuyama, Yukio; Kohno, Atsushi; Shigeta, Teiko (Tokyo Women' s Medical Coll. (Japan))

    1990-03-01

    We studied the 3rd lumbar vertebral trabecular bone mineral density in 59 cross-sectional pictures of quantitative computed tomography (QCT) with CaCO{sub 3} phantom for 28 hospital control children and 30 cases of suspected bone metabolic disorders. The QCT value of bone mineral density of control children showed neither age dependency nor sexual difference before puberty: for males was 221.8{plus minus}30.2 mg CaCO{sub 3}/cm{sup 3} (Mean{plus minus}SD) under 4 years, 218.1{plus minus}39.7 at 5{approx}9 years and 217.2{plus minus}30.9 at 10{approx}15 years; and for females 220.9{plus minus}18.3 under 4 years and 240.0{plus minus}29.4 at 5{approx}9 years. The QCT values of bone mineral density in bed-ridden patients, children receiving glucocorticoids, and children receiving anticonvulsants were significantly lower than that in control children (p<0.005). The QCT value of bone mineral density of bed-ridden patients was significantly lower than that of children receiving glucocorticoids and of children receiving anticonvulsants (p<0.05, p<0.005 respectively). Our study confirmed that single energy quantitative CT was very useful in pediatric clinical application. (author).

  6. Three-dimensional characterization of the vascular bed in bone metastasis of the rat by microcomputed tomography (MicroCT.

    Directory of Open Access Journals (Sweden)

    Hervé Nyangoga

    Full Text Available BACKGROUND: Angiogenesis contributes to proliferation and metastatic dissemination of cancer cells. Anatomy of blood vessels in tumors has been characterized with 2D techniques (histology or angiography. They are not fully representative of the trajectories of vessels throughout the tissues and are not adapted to analyze changes occurring inside the bone marrow cavities. METHODOLOGY/PRINCIPAL FINDINGS: We have characterized the vasculature of bone metastases in 3D at different times of evolution of the disease. Metastases were induced in the femur of Wistar rats by a local injection of Walker 256/B cells. Microfil®, (a silicone-based polymer was injected at euthanasia in the aorta 12, 19 and 26 days after injection of tumor cells. Undecalcified bones (containing the radio opaque vascular casts were analyzed by microCT, and a first 3D model was reconstructed. Bones were then decalcified and reanalyzed by microCT; a second model (comprising only the vessels was obtained and overimposed on the former, thus providing a clear visualization of vessel trajectories in the invaded metaphysic allowing quantitative evaluation of the vascular volume and vessel diameter. Histological analysis of the marrow was possible on the decalcified specimens. Walker 256/B cells induced a marked osteolysis with cortical perforations. The metaphysis of invaded bones became progressively hypervascular. New vessels replaced the major central medullar artery coming from the diaphyseal shaft. They sprouted from the periosteum and extended into the metastatic area. The newly formed vessels were irregular in diameter, tortuous with a disorganized architecture. A quantitative analysis of vascular volume indicated that neoangiogenesis increased with the development of the tumor with the appearance of vessels with a larger diameter. CONCLUSION: This new method evidenced the tumor angiogenesis in 3D at different development times of the metastasis growth. Bone and the vascular

  7. 3-D颞骨模型的制作与应用%Manufacture and Application of Three-dimensional Prototyped Model of Temporal Bone

    Institute of Scientific and Technical Information of China (English)

    杨静雅; 田广永; 黄文华; 许靖; 吴章林; 张芳

    2015-01-01

    目的:探讨利用粉末堆积打印技术制作的高仿真3-D颞骨模型在解剖技能训练及模拟手术中的应用。方法利用高分辨率CT获取活体颞骨断层图像(正常人2例,慢性中耳炎患者2例),数据导入Mimics软件行图像分割及颞骨三维重建,以石膏粉末为原料,利用粉末堆积快速成型技术打印出颞骨模型,重要解剖结构与组织(听骨链、面神经、位听器、炎性渗出及胆脂瘤等)以不同颜色打印,并在显微镜下进行手术演练。结果颞骨模型的硬度与人骨相近,模型表面及内部骨性标志明显,解剖精确度高,钻磨触感接近真实,满足颞骨解剖技能训练及模拟手术的要求。结论利用粉末堆积打印技术能制作出仿真度更高、更接近实际人体解剖结构的颞骨模型,帮助临床医生在术前全面了解患者的颞骨及周围组织解剖结构与病变情况,制定和优化手术方案,减少并发症。%Objective The aim of this study was to investigate the temporal bone model of high precision for anatomi⁃cal skill chaining and surgery simulation by using 3-D printing technology. Methods A high-resolution computed tomogra⁃phy (CT) images were obtained from 2 normal human and 2 chronic tympanitis temporal bone . The Mimics was use for image segmentation and three-dimensional reconstruction. The temporal bone model was duplicated with Powder packing rapid pro⁃totyping technology with the material of plaster powder. The printer applied colors to the important components (like ossicular chain, facial nerve and vestibulocochlear organ ). Operational practice was performed under a microscope. Results The mate⁃rial properties were as hard as real bone. Anatomic details of the temporal bone model were dimensionally accurate and gener⁃ally comparable to the human temporal bone. Conclusion The anatomic and haptic fidelity of the temporal bone model could be manufactured by the

  8. Computed tomography and magnetic resonance imaging of congenital abnormalities of the temporal bone; Computertomographie und Magnetresonanztomographie kongenitaler Veraenderungen des aeusseren Ohrs, Mittel- und Innenohrs sowie des inneren Gehoergangs

    Energy Technology Data Exchange (ETDEWEB)

    Czerny, C.; Imhof, H. [Abteilung fuer Osteologie, Univ.-Klinik fuer Radiodiagnostik, Wien (Austria); Gstoettner, W. [Univ.-Klinik fuer Hals-Nasen-Ohren-Heilkunde, Frankfurt/Main (Germany)

    2003-03-01

    Congenital abnormalities of the temporal bone are mostly accompanied by conductive or sensori-neural hearing loss. Before any therapeutic procedures are done high resolution CT (HRCT) and magnetic resonance imaging (MRI) should be performed to establish the correct diagnosis and to plan the potentially surgical intervention. HRCT best depicts osseous changes especially those of the external auditory canal and the middle ear containing the ossicles and the osseous structures of the temporal bone and the petrous bone containing the inner ear. MRI excellently shows soft tissue changes of the inner ear especially on the high resolution 3DT2-weighted sequences which give a superb contrast between the nerves and the cerebro-spinal fluid. Malformations of the external auditory canal consists of aplasia or hypoplasia and those of the middle ear range form extreme hypoplasia or aplasia to very mild deformations of the ossicles. Malformations of the inner ear also range form complete aplasia to very mild hypoplasia of the organs of the inner ear as well as malformations concerning the nerves in the internal auditory canal range from aplasia to hypoplasia. Malformations of the temporal bone can either occur isolated or in combination in which malformations of the external and middle ear may be accompanied by those of the inner ear. Furthermore, malformations of the temporal bone may also occur in otofacial, otocervical or otoskeletal syndromes. These syndromes may be accompanied by certain malformations of the temporal bone. HRCT and MRI are both excellent methods to depict congenital abnormalities of the temporal bone and of the inner ear and should be used as complementary methods because HRCT best depicts osseous changes and MRI superbly depicts soft tissue changes. Both methods are important to establish the correct diagnosis to plan the therapeutic procedures. (orig.) [German] Angeborene Missbildungen des Schlaefenbeins sind oft mit Schwerhoerigkeit bis Taubheit

  9. SU-E-J-250: A Methodology for Active Bone Marrow Protection for Cervical Cancer Intensity-Modulated Radiotherapy Using 18F-FLT PET/CT Image

    Energy Technology Data Exchange (ETDEWEB)

    Ma, C; Yin, Y [Shandong Cancer Hospital, Jinan, Shandong (China)

    2014-06-01

    Purpose: The purpose of this study was to compare a radiation therapy treatment planning that would spare active bone marrow and whole pelvic bone marrow using 18F FLT PET/CT image. Methods: We have developed an IMRT planning methodology to incorporate functional PET imaging using 18F FLT/CT scans. Plans were generated for two cervical cancer patients, where pelvicactive bone marrow region was incorporated as avoidance regions based on the range: SUV>2., another region was whole pelvic bone marrow. Dose objectives were set to reduce the volume of active bone marrow and whole bone marraw. The volumes of received 10 (V10) and 20 (V20) Gy for active bone marrow were evaluated. Results: Active bone marrow regions identified by 18F FLT with an SUV>2 represented an average of 48.0% of the total osseous pelvis for the two cases studied. Improved dose volume histograms for identified bone marrow SUV volumes and decreases in V10(average 18%), and V20(average 14%) were achieved without clinically significant changes to PTV or OAR doses. Conclusion: Incorporation of 18F FLT/CT PET in IMRT planning provides a methodology to reduce radiation dose to active bone marrow without compromising PTV or OAR dose objectives in cervical cancer.

  10. Analysis of Imaging Characteristics of 18F-FDG PET/CT in Misdiagnosed Bone Tuberculosis: A Report of 12 Cases

    Directory of Open Access Journals (Sweden)

    Qi-yong DING

    2015-12-01

    Full Text Available Abstract Objective: To analyze the imaging characteristics of 18F-fluorodeoxyglucose positron emission tomography/computer tomography (18F-FDG PET/CT in 12 cases of misdiagnosed bone tuberculosis so as to explore the differential diagnostic method with metastatic bone tumors. Methods: The images of 12 patients with bone tuberculosis diagnosed by 18F-FDG PET/CT were retrospectively analyzed. Distribution of lesion locations in the whole body and characteristics of glucose metabolism were analyzed by qualitative and semi-quantitative methods, especially for bone lesion location, number and range, glucose uptake form and CT imaging characteristics, and the maximum of standardized uptake value (SUVmax was measured and recorded. Results: Of 12 patients, 1 showed increased glucose uptake of diffuse bone marrow in the whole body, whereas the rest suffered from 19 bone lesions, in which each one had 1 bone lesion in 9 cases, accounting for 75.0%. The images of PET/CT in 12 patients primarily manifested annular or nonuniform increase of glucose uptake (63.2%, sequestrum within osteolytic lesions (31.6%, injured intervertebral disc caused by vertebral lesions (61.5% and cold abscess es around the lesions (68.4%. The glucose uptake rate of cold abscesses was higher than that of bone lesion locations. The tuberculosis complicated with other parts included lymphatic tuberculosis (100.0%, pulmonary tuberculosis (66.7%, pericardial or pleural tuberculosis (25.0% and hepatolienal tuberculosis (8.3%. Conclusion: The characteristics of bone tuberculosis lesions are prominent in 18F-FDG PET/CT imaging, which could contribute to diagnosis of whole body tuberculosis and has a greater value in the differentiation of bone tuberculosis and metastatic bone tumors.

  11. Analysis of Imaging Characteristics of18F-FDG PET/CT in Misdiagnosed Bone Tuberculosis:A Report of 12 Cases

    Institute of Scientific and Technical Information of China (English)

    DING Qi-yong; LI Tian-nyu; CHEN Jian-wei; LIU Lian-ke

    2015-01-01

    Objective: To analyze the imaging characteristics of18F-lfuorodeoxyglucose positron emission tomography/computer tomography (18F-FDG PET/CT) in 12 cases of misdiagnosed bone tuberculosis so as to explore the differential diagnostic method with metastatic bone tumors. Methods: The images of 12 patients with bone tuberculosis diagnosed by18F-FDG PET/CT were retrospectively analyzed. Distribution of lesion locations in the whole body and characteristics of glucose metabolism were analyzed by qualitative and semi-quantitative methods, especially for bone lesion location, number and range, glucose uptake form and CT imaging characteristics, and the maximum of standardized uptake value (SUVmax) was measured and recorded. Results: Of 12 patients, 1 showed increased glucose uptake of diffuse bone marrow in the whole body, whereas the rest suffered from 19 bone lesions, in which each one had 1 bone lesion in 9 cases, accounting for 75.0%. The images of PET/CT in 12 patients primarily manifested annular or nonuniform increase of glucose uptake (63.2%), sequestrum within osteolytic lesions (31.6%), injured intervertebral disc caused by vertebral lesions (61.5%) and cold abscesses around the lesions (68.4%). The glucose uptake rate of cold abscesses was higher than that of bone lesion locations. The tuberculosis complicated with other parts included lymphatic tuberculosis (100.0%), pulmonary tuberculosis (66.7%), pericardial or pleural tuberculosis (25.0%) and hepatolienal tuberculosis (8.3%). Conclusion: The characteristics of bone tuberculosis lesions are prominent in18F-FDG PET/CT imaging, which could contribute to diagnosis of whole body tuberculosis and has a greater value in the differentiation of bone tuberculosis and metastatic bone tumors.

  12. PET and PET/CT with {sup 18}F-fluoride in the diagnosis of bone metastases; PET und PET/CT mit {sup 18}F-Fluorid in der Diagnostik von Knochenmetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Schmiedel, B.; Palmedo, H. [Klinik und Poliklinik fuer Nuklearmedizin, Universitaetsklinikum Bonn (Germany)

    2006-12-15

    The exact tumor stage needs to be determined with the help of the TNM classification before the optimal therapeutic procedure for the patient is proposed. If M-staging is under question bone metastases must be excluded or be proven. Bone scintigraphy plays a major role for bone metastases screening of patients with lung cancer, prostate and breast cancer in whom osseous disease is often present. The result of bone scintigraphy has a significant impact on further therapy e.g. whether curative treatment is possible, whether operative resection or chemotherapy must be performed. PET and PET/CT with {sup 18}F sodium fluoride are new imaging modalities for the detection of bone metastases. PET with {sup 18}F fluoride allows for cross sectional imaging with high resolution in a way that is not achievable by conventional bone scintigraphy. Pharmacokinetic properties of {sup 18}F fluoride are advantageous and lead to high tracer uptake and quick renal clearance. This allows the acquisition of high quality images as early as one hour after the injection. Compared with planar whole body scintigraphy, {sup 18}F fluoride is able to detect significantly more bone metastases (especially in the vertebral column). In comparison to bone SPECT, less additional metastatic lesions are detected by bone PET. This could be demonstrated in detail for lung and prostate cancers. In a small group of patients, {sup 18}F fluoride will diagnose osseous metastatic disease in spite of a negative planar whole body scintigraphy and a negative bone SPECT. However, specificity of bone SPECT is not markedly improved by {sup 18}F fluoride PET. It seems that new camera systems like PET/CT and SPECT/CT can enhance specificity impressively by adding the CT component to exactly localize a tracer accumulation. (orig.)

  13. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans,

  14. Visualization of postoperative anterior cruciate ligament reconstruction bone tunnels: Reliability of standard radiographs, CT scans, and 3D virtual reality images

    NARCIS (Netherlands)

    D.E. Meuffels (Duncan); J.W. Potters (Jan Willem); A.H.J. Koning (Anton); C.H. Brown Jr Jr. (Charles); J.A.N. Verhaar (Jan); M. Reijman (Max)

    2011-01-01

    textabstractBackground and purpose: Non-anatomic bone tunnel placement is the most common cause of a failed ACL reconstruction. Accurate and reproducible methods to visualize and document bone tunnel placement are therefore important. We evaluated the reliability of standard radiographs, CT scans, a

  15. Use of CT in the evaluation of cochlear otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Mafee, M.F.; Valvassori, G.E.; Deitch, R.L.; Norouzi, P.; Henrikson, G.C.; Capek, V.; Applebaum, E.L.

    1985-09-01

    Otosclerosis (otospongiosis) occurs when the hard endochondral bone of the otic capsule is replaced by spongy vascular foci of haversian bone. Using computed tomography (CT), the authors studied the ears of 32 selected patients with mixed or sensorineural hearing loss; 24 were suspected of having otosclerosis. CT proved valuable in detecting cochlear otosclerosis, foci of demineralization, and changes in bony texture and enables the easy recognition of subtle radiographic findings. This paper also reports the CT findings of temporal bones in osteogenesis imperfecta and Paget disease.

  16. Integration of comprehensive 3D microCT and signaling analysis reveals differential regulatory mechanisms of craniofacial bone development.

    Science.gov (United States)

    Ho, Thach-Vu; Iwata, Junichi; Ho, Hoang Anh; Grimes, Weston C; Park, Shery; Sanchez-Lara, Pedro A; Chai, Yang

    2015-04-15

    Growth factor signaling regulates tissue-tissue interactions to control organogenesis and tissue homeostasis. Specifically, transforming growth factor beta (TGFβ) signaling plays a crucial role in the development of cranial neural crest (CNC) cell-derived bone, and loss of Tgfbr2 in CNC cells results in craniofacial skeletal malformations. Our recent studies indicate that non-canonical TGFβ signaling is activated whereas canonical TGFβ signaling is compromised in the absence of Tgfbr2 (in Tgfbr2(fl/fl);Wnt1-Cre mice). A haploinsufficiency of Tgfbr1 (aka Alk5) (Tgfbr2(fl/fl);Wnt1-Cre;Alk5(fl/+)) largely rescues craniofacial deformities in Tgfbr2 mutant mice by reducing ectopic non-canonical TGFβ signaling. However, the relative involvement of canonical and non-canonical TGFβ signaling in regulating specific craniofacial bone formation remains unclear. We compared the size and volume of CNC-derived craniofacial bones (frontal bone, premaxilla, maxilla, palatine bone, and mandible) from E18.5 control, Tgfbr2(fl/fl);Wnt1-Cre, and Tgfbr2(fl/fl);Wnt1-Cre;Alk5(fl/+)mice. By analyzing three dimensional (3D) micro-computed tomography (microCT) images, we found that different craniofacial bones were restored to different degrees in Tgfbr2(fl/fl);Wnt1-Cre;Alk5(fl/+) mice. Our study provides comprehensive information on anatomical landmarks and the size and volume of each craniofacial bone, as well as insights into the extent that canonical and non-canonical TGFβ signaling cascades contribute to the formation of each CNC-derived bone. Our data will serve as an important resource for developmental biologists who are interested in craniofacial morphogenesis.

  17. Rigid model-based 3D segmentation of the bones of joints in MR and CT images for motion analysis.

    Science.gov (United States)

    Liu, Jiamin; Udupa, Jayaram K; Saha, Punam K; Odhner, Dewey; Hirsch, Bruce E; Siegler, Sorin; Simon, Scott; Winkelstein, Beth A

    2008-08-01

    There are several medical application areas that require the segmentation and separation of the component bones of joints in a sequence of images of the joint acquired under various loading conditions, our own target area being joint motion analysis. This is a challenging problem due to the proximity of bones at the joint, partial volume effects, and other imaging modality-specific factors that confound boundary contrast. In this article, a two-step model-based segmentation strategy is proposed that utilizes the unique context of the current application wherein the shape of each individual bone is preserved in all scans of a particular joint while the spatial arrangement of the bones alters significantly among bones and scans. In the first step, a rigid deterministic model of the bone is generated from a segmentation of the bone in the image corresponding to one position of the joint by using the live wire method. Subsequently, in other images of the same joint, this model is used to search for the same bone by minimizing an energy function that utilizes both boundary- and region-based information. An evaluation of the method by utilizing a total of 60 data sets on MR and CT images of the ankle complex and cervical spine indicates that the segmentations agree very closely with the live wire segmentations, yielding true positive and false positive volume fractions in the range 89%-97% and 0.2%-0.7%. The method requires 1-2 minutes of operator time and 6-7 min of computer time per data set, which makes it significantly more efficient than live wire-the method currently available for the task that can be used routinely.

  18. Multimodal-3D imaging based on μMRI and μCT techniques bridges the gap with histology in visualization of the bone regeneration process.

    Science.gov (United States)

    Sinibaldi, R; Conti, A; Sinjari, B; Spadone, S; Pecci, R; Palombo, M; Komlev, V S; Ortore, M G; Tromba, G; Capuani, S; De Luca, F; Caputi, S; Traini, T; Della Penna, S

    2017-06-07

    Bone repair/regeneration is usually investigated through x-ray computed microtomography (μCT) supported by histology of extracted samples, to analyze biomaterial structure and new bone formation processes. Magnetic Resonance Imaging (μMRI) shows a richer tissue contrast than μCT, despite at lower resolution, and could be combined with μCT in the perspective of conducting non-destructive 3D investigations of bone. A pipeline designed to combine μMRI and μCT images of bone samples is here described and applied on samples of extracted human jawbone core following bone graft. We optimized the co-registration procedure between μCT and μMRI images to avoid bias due to the different resolutions and contrasts. Furthermore, we used an Adaptive Multivariate Clustering, grouping homologous voxels in the co-registered images, to visualize different tissue types within a fused 3D metastructure. The tissue grouping matched the 2D histology applied only on one slice, thus extending the histology labelling in 3D. Specifically, in all samples we could separate and map two types of regenerated bone, calcified tissue, soft tissues and/or fat and marrow space. Remarkably, μMRI and μCT alone were not able to separate the two types of regenerated bone. Finally, we computed volumes of each tissue in the 3D metastructures, which might be exploited by quantitative simulation. The 3D metastructure obtained through our pipeline represents a first step to bridge the gap between the quality of information obtained from 2D optical microscopy and the 3D mapping of the bone tissue heterogeneity, and could allow researchers and clinicians to non-destructively characterize and follow-up bone regeneration. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. 68Ga-PSMA PET/CT for the detection of bone metastasis in recurrent prostate cancer and a PSA level <2 ng/ml

    DEFF Research Database (Denmark)

    Petersen, Lars J; Nielsen, Julie B; Dettmann, Katja

    2017-01-01

    /computed tomography ((68)Ga-PSMA PET/CT) is a novel and promising method for imaging in prostate cancer. The present study reports two cases of patients with prostate cancer with biochemical recurrence, with evidence of bone metastases on (68)Ga-PSMA PET/CT images and low prostate specific antigen PSA levels (.../ml) and PSA doubling time >6 months. The bone metastases were verified by supplementary imaging with (18)F-sodium fluoride PET/CT and magnetic resonance imaging as well as biochemical responses to androgen deprivation therapy. Therefore, (68)Ga-PSMA PET/CT is promising for the restaging of patients......Localization of prostate cancer recurrence, particularly in the bones, is a major challenge with standard of care imaging in patients with biochemical recurrence following curatively intended treatment. Gallium-68-labeled prostate specific membrane antigen positron emission tomography...

  20. Decolonizing Straight Temporality Through Genre Trouble in Edwidge Danticat's The Farming of Bones

    Directory of Open Access Journals (Sweden)

    Eliana de Souza Ávila

    2014-12-01

    Full Text Available http://dx.doi.org/10.5007/2175-8026.2014n67p21 Framing genre trouble (McKenzie 2006 as a decolonial methodology, this paper considers the relevance of Edwidge Danticat’s The Farming of Bones (1998 for reading migrant texts against the grain of straight temporality which sustains the coloniality of power (Lugones 2007. Scrutinizing historiographic suppression, Danticat’s migrant text interrupts the chrononormative portrayal of the Trujillo genocide of Haitian workers in the Dominican Republic as a reality pertaining to an obsolete past and to the geocultural margins alone. Read in the aftermath of the testimonio controversy, it may thus decenter the ongoing deflection of attention from Rigoberta Menchú’s impact on the geocultural structures that sanction ongoing military intervention and genocide by refocusing on historiography as a terrain of relentless decolonial contestation rather than prescriptive narrative closure.

  1. Eosinophilic granuloma of the temporal bone- its clinical manifestations and management

    Directory of Open Access Journals (Sweden)

    Kirtane Jyotsna

    1978-01-01

    Full Text Available Eosinophilic granuloma is a variety of Histiocytosis-X. Its etio-logy is unknown. When it involves the temporal bone it may mimic chronic otitis media, or a mastoid abscess, very often leading to an erroneous diagnosis. Its X-ray appearance and histopathology are characteristic. Infiltration with eosinophils and histiocytes is a constant feature. Very good results are achieved with surgery accompanied by radiotherapy. In this series of 3 patients, one pa-tient presented with facial paralysis and another one with bilateral post-auricular swellings. The first 2 cases were diagnosed only after surgery and histopathological examination of the tissue removed, while the third case was diagnosed pre-operatively on clinical and radiological findings.

  2. Clinical and experimental study on facial paralysis in temporal bone fracture

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Objective: To study the main prognostic factors and significanceof facial nerve decompression for facial paralysis in temporal bone fracture.Methods: The main relative prognostic factors of 64 patients with facial paralysis were analyzed. An experimental model of facial paralysis was made. The expansion rates of facial nerve in the facial canal opening group and the facial canal non-opening group were measured and observed under electron microscope.Results: The main factors affecting the prognosis were facial nerve decompression and selection of surgery time. The expansion rate of facial nerve in the facial canal opening group was significantly higher than that of the facial canal non-opening group (t=7.53, P<0.01). The injury degree of the nerve fiber in the facial canal non-opening group was severe.Conclusions: Early facial nerve decompression is beneficial to restoration of the facial nerve function.

  3. Concurrent necrotising otitis externa and adenocarcinoma of the temporal bone: a diagnostic challenge.

    Science.gov (United States)

    Foden, Neil; Burgess, Christopher; Damato, Stephen; Ramsden, James

    2013-11-06

    We present a case of an 81-year-old man who was diagnosed with a necrotising (malignant) otitis externa (NOE). Initial biopsies from the external auditory canal showed scanty squamous epithelium but no evidence of malignancy. Despite an initial improvement on intravenous antibiotics and subsequent discharge from hospital, the patient returned with worsening otalgia. Following readmission to the hospital, intravenous antibiotics were restarted. Despite this, the patient developed a lower motor neurone palsy of cranial nerve VII on the ipsilateral side of the pain. He was taken to the theatre for an exploration of the left mastoid with further biopsies. Adenocarcinoma was diagnosed histologically and the patient was started on palliative radiotherapy. This case adds to the known literature on metastatic disease in the temporal bone and highlights the need to exclude malignancy in cases of NOE.

  4. FDG PET/CT in Early and Late Stages of SAPHO Syndrome: Two Case Reports With MRI and Bone Scintigraphy Correlation.

    Science.gov (United States)

    Dong, Aisheng; Bai, Yushu; Cui, Yong; Zhang, Jian; Zuo, Changjing

    2016-04-01

    Synovitis, acne, pustulosis, hyperostosis, and osteitis (SAPHO) syndrome is a rare disease, which may be underdiagnosed or misdiagnosed because of nonspecific clinical and imaging findings. We present 2 cases of SAPHO syndrome with MRI, bone scintigraphy, and FDG PET/CT findings. In case 1 with early-stage disease, the active osteitis showed osteolytic bone destruction with increased FDG uptake. In case 2 with late-stage disease, the inactive bone lesions presented as osteosclerosis with normal FDG uptake. Familiarity with the FDG PET/CT findings of SAPHO syndrome in different stages may be helpful for correct diagnosis.

  5. Does the presence of tumor-induced cortical bone destruction at CT have any prognostic value in newly diagnosed diffuse large B-cell lymphoma?

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A.; Nievelstein, Rutger A.J.; Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Klerk, John M.H. de [Meander Medical Center, Department of Nuclear Medicine, Amersfoort (Netherlands); Fijnheer, Rob [Meander Medical Center, Department of Hematology, Amersfoort (Netherlands); Heggelman, Ben G.F. [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Dubois, Stefan V. [Meander Medical Center, Department of Pathology, Amersfoort (Netherlands)

    2015-05-01

    To determine the prognostic value of tumor-induced cortical bone destruction at computed tomography (CT) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). This retrospective study included 105 patients with newly diagnosed DLBCL who had undergone CT and bone marrow biopsy (BMB) before R-CHOP (rituximab, cyclophosphamide, hydroxydaunorubicin, Oncovin, and prednisolone) chemo-immunotherapy. Cox regression analyses were used to determine the associations of cortical bone status at CT (absence vs. presence of tumor-induced cortical bone destruction), BMB findings (negative vs. positive for lymphomatous involvement), and dichotomized National Comprehensive Cancer Network International Prognostic Index (NCCN-IPI) strata (low risk vs. high risk) with progression-free survival (PFS) and overall survival (OS). Univariate Cox regression analysis indicated that cortical bone status at CT was no significant predictor of either PFS or OS (p = 0.358 and p = 0.560, respectively), whereas BMB findings (p = 0.002 and p = 0.013, respectively) and dichotomized NCCN-IPI risk strata (p = 0.002 and p = 0.003, respectively) were significant predictors of both PFS and OS. In the multivariate Cox proportional hazards model, only the dichotomized NCCN-IPI score was an independent predictive factor of PFS and OS (p = 0.004 and p = 0.003, respectively). The presence of tumor-induced cortical bone destruction at CT was not found to have any prognostic implications in newly diagnosed DLBCL. (orig.)

  6. Lactase gene c/t(-13910) polymorphism, calcium intake, and pQCT bone traits in Finnish adults.

    Science.gov (United States)

    Tolonen, Sanna; Laaksonen, Marika; Mikkilä, Vera; Sievänen, Harri; Mononen, Nina; Räsänen, Leena; Viikari, Jorma; Raitakari, Olli T; Kähönen, Mika; Lehtimäki, Terho J

    2011-02-01

    Genetic lactase nonpersistence may influence calcium intake and thereby bone health. We investigated in the Cardiovascular Risk in Young Finn Study whether young adults aged 31-46 years with the C/C(-13910) genotype are more susceptible to reduced bone phenotypes, low-energy fractures, and low calcium intake than subjects with other lactase genotypes. We also analyzed the gene-environment interactions on bone with calcium intake and physical activity. Peripheral quantitative computed tomography bone traits were measured from the distal and shaft sites of the radius and tibia. The total number of those subjects whose nondominant forearm was measured and the lactase genotype was defined was 1551. Information on diet, lifestyle factors, and fractures was collected with questionnaires. The mean intake of calcium was the lowest in men with the C/C(-13910) genotype (P = 0.001). Men with the T/T(-13910) genotype had ~3% higher trabecular density at the distal radius and distal tibia compared to other lactase genotypes (P = 0.03 and 0.02, respectively). In women, we found no evidence of the gene effect at the radius and tibia. No major interactions of the C/T(-13910) polymorphism with calcium intake or physical activity on bone phenotypes were found in either sex. In conclusion, the C/T(-13910) polymorphism was associated with trabecular density at the distal radius and tibia in men. These differences may be due to the differences in calcium intake between the lactase genotypes.

  7. Role of {sup 11}C-choline PET/CT in the re-staging of prostate cancer patients with biochemical relapse and negative results at bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fuccio, Chiara; Castellucci, Paolo [Nuclear Medicine Unit, Department of Hematology Oncology and Laboratory Medicine, Azienda Ospedaliero - Universitaria di Bologna Policlinico Sant' Orsola - Malpighi, University of Bologna, Bologna (Italy); Schiavina, Riccardo [Urology Unit, Department of Specialist Surgery and Anaesthesiology, Azienda Ospedaliero - Universitaria di Bologna Policlinico Sant' Orsola - Malpighi, University of Bologna, Bologna (Italy); Guidalotti, Pier Luigi; Gavaruzzi, Gilberto; Montini, Gian Carlo; Nanni, Cristina [Nuclear Medicine Unit, Department of Hematology Oncology and Laboratory Medicine, Azienda Ospedaliero - Universitaria di Bologna Policlinico Sant' Orsola - Malpighi, University of Bologna, Bologna (Italy); Marzola, Maria Cristina [Department of Nuclear Medicine and PET/CT Centre, ' Santa Maria della Misericordia' Hospital, Via Tre Martiri 140, 45100 Rovigo (Italy); Rubello, Domenico, E-mail: domenico.rubello@libero.it [Department of Nuclear Medicine and PET/CT Centre, ' Santa Maria della Misericordia' Hospital, Via Tre Martiri 140, 45100 Rovigo (Italy); Fanti, Stefano [Nuclear Medicine Unit, Department of Hematology Oncology and Laboratory Medicine, Azienda Ospedaliero - Universitaria di Bologna Policlinico Sant' Orsola - Malpighi, University of Bologna, Bologna (Italy)

    2012-08-15

    Aim: to evaluate the utility of {sup 11}C-choline PET/CT in prostate cancer (PC) patients who have demonstrated a biochemical recurrence and a negative bone scintigraphy (BS). Materials and methods: 123 consecutive PC patients (mean age 67.6 years; range 54-83) with a biochemical relapse (mean PSA value 3.3 ng/mL; range 0.2-25.5) after radical prostatectomy (RP) were included in our retrospective study. Patients underwent a BS that resulted negative and a {sup 11}C-choline PET/CT within 4 months from BS (range: 1 day to 4 months; mean: 2.5 months). Validation of results was established by: (1) a positive biopsy, (2) a positive subsequent BS, CT or MR and (3) a normalization of {sup 11}C-choline uptake after systemic therapy or a progression of the disease. Results: {sup 11}C-choline PET/CT was positive in 42/123 patients (34.1%). {sup 11}C-choline PET/CT detected lesions in: bone (10 patients), lymph-nodes (20 patients), bone and lymph nodes (7 patients), bone and lung (1 patient), lymph-nodes and lung (1 patient), local relapse (3 patients). Overall, {sup 11}C-choline PET/CT showed a total of 30 unknown bone lesions in 18/123 (14.6%) patients. Conclusion: {sup 11}C-choline PET/CT showed a better sensitivity than BS in patients with biochemical relapse after RP: {sup 11}C-choline PET/CT detected unknown bone lesions in 18/123 (14.6%) patients.

  8. High resolution CT in the investigation of bone destruction in the outer ear

    Energy Technology Data Exchange (ETDEWEB)

    Koester, O.; Straehler-Pohl, H.J.

    1986-12-01

    Eleven patients with known malignant tumours of the outer ear and three patients with otitis externa maligna were examined by high resolution CT. CT provided accurate information concerning soft tissue infiltration into the parotid or subtemporal tissues, and of the bony destruction in the mastoid, meatus and tympanic cavity. Absolute differentiation between a malignant tumour and otitis cisterna maligna is not possible, not even by high resolution CT.

  9. Giant cell granuloma of the temporal bone in a mixed martial arts fighter.

    Science.gov (United States)

    Maerki, Jennifer; Riddle, Nicole D; Newman, Jason; Husson, Michael A; Lee, John Y K

    2012-10-01

    Background and Importance Giant cell granuloma (GCG) is a rare, benign, non-neoplastic lesion of the head and neck. More common in the jaw bones, there have been few reports of the lesion arising in the temporal bone. Initially referred to as a "giant cell reparative granuloma," due to the previously accepted notion of its nature in attempting to repair areas of injury, the term "giant cell granuloma" is now more frequently used as this lesion has been found in patients without a history of trauma. In addition, several cases with a destructive nature, in contrast to a reparative one, have been observed. Clinical Presentation We report a case of GCG presenting as a head and neck tumor with dural attachments and extension into the middle cranial fossa in a mixed martial arts fighter. Conclusion Giant cell granulomas are typically treated surgically and have a good prognosis; however, care must be taken when they present in unusual locations. This case supports the theory of trauma and inflammation as risk factors for GCG.

  10. Relationship between clinical sinusitis symptoms and sinus CT severity in pediatric post bone marrow transplant and immunocompetent patients

    Science.gov (United States)

    Arulrajah, Sahayini; Symons, Heather; Cahoon, Elizabeth Khaykin; Tekes, Aylin; Huisman, Thierry A. G. M.

    2014-01-01

    Since typical inflammatory responses may be diminished in children following bone marrow transplant (BMT), computed tomography (CT) imaging of the sinuses has been increasingly ordered to diagnose sinusitis in this group. The objective of this study was to determine the association between clinical sinusitis symptoms and sinus opacification on CT scans in post BMT versus immunocompetent children. Our sample was comprised of 64 post BMT and 86 immunocompetent children with sinus CT scans. CT sinus opacification was scored using the modified Lund–Mackay staging system. The relationship between clinical sinusitis symptoms (rhinorrhea, nasal congestion, cough, headache, and facial pain) and opacification was compared for the two groups. The severity of sinus opacification in the BMT group was significantly higher compared to the immunocompetent group. In combined patient groups the odds ratio (OR) for moderate/severe sinusitis was significantly elevated for rhinorrhea (OR=3.00; 95% confidence interval [CI], 1.27–7.12), cough (OR=2.80; 95% CI, 1.22–6.42), and having either rhinorrhea, nasal congestion, or cough (OR= 4.76; 95% CI, 1.71–13.24). While the immunocompetent group had a greater number of sinusitis symptoms compared to the post BMT group, both groups had a significant increase in the severity on CT with increasing number of symptoms. Conclusion In post BMT patients, our data demonstrated higher odds of moderate/severe sinusitis on CT scans associated with rhinorrhea, cough or nasal congestion. These finding suggest that in post BMT children, detailed sinus history may still play a vital role in the diagnosis of sinusitis. PMID:21904829

  11. Longitudinal in vivo evaluation of bone regeneration by combined measurement of multi-pinhole SPECT and micro-CT for tissue engineering

    Science.gov (United States)

    Lienemann, Philipp S.; Metzger, Stéphanie; Kiveliö, Anna-Sofia; Blanc, Alain; Papageorgiou, Panagiota; Astolfo, Alberto; Pinzer, Bernd R.; Cinelli, Paolo; Weber, Franz E.; Schibli, Roger; Béhé, Martin; Ehrbar, Martin

    2015-05-01

    Over the last decades, great strides were made in the development of novel implants for the treatment of bone defects. The increasing versatility and complexity of these implant designs request for concurrent advances in means to assess in vivo the course of induced bone formation in preclinical models. Since its discovery, micro-computed tomography (micro-CT) has excelled as powerful high-resolution technique for non-invasive assessment of newly formed bone tissue. However, micro-CT fails to provide spatiotemporal information on biological processes ongoing during bone regeneration. Conversely, due to the versatile applicability and cost-effectiveness, single photon emission computed tomography (SPECT) would be an ideal technique for assessing such biological processes with high sensitivity and for nuclear imaging comparably high resolution (guide the healing of critical sized calvarial bone defects. By combined in vivo longitudinal multi-pinhole SPECT and micro-CT evaluations we determine the spatiotemporal course of bone formation and remodeling within this synthetic hydrogel implant. End point evaluations by high resolution micro-CT and histological evaluation confirm the value of this approach to follow and optimize bone-inducing biomaterials.

  12. Diagnostic management of patients with SAPHO syndrome: use of MR imaging to guide bone biopsy at CT for microbiological and histological work-up

    Energy Technology Data Exchange (ETDEWEB)

    Kirchhoff, Timm; Rosenthal, Herbert; Prokop, Mathias; Chavan, Ajay; Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover (Germany); Merkesdal, Sonja; Wagner, Annette; Zeidler, Henning [Department of Rheumatology, Hannover Medical School, Carl-Neuberg Strasse 1, 30625, Hannover (Germany); Mai, Uwe [Institut fuer Med. Mikrobiologie und Hygiene, Haltenhoffstrasse 41, 30167, Hannover (Germany); Hammer, Michael [Klinik fuer Rheumatologie, St. Josef-Stift, 48324, Sendenhorst (Germany)

    2003-10-01

    Propionibacterium acnes (P. acnes) is suspected to be involved in the pathophysiology of SAPHO syndrome, since it has been isolated repeatedly through open surgical bone biopsy. This study demonstrates the role of MRI in identifying inflamed bone areas in patients with SAPHO syndrome and the role of CT-guided bone biopsies in obtaining samples from these areas for microbiological and histopathological investigations, thus obviating open surgery. Fourteen consecutive patients with SAPHO syndrome were investigated by MRI to identify acute inflammatory changes in hyperostotic periarticular bone. The CT-guided biopsies for microbiological investigations were taken from the areas identified. Patients positive for P. acnes were started on long-term antibiotic therapy according to antibiotic susceptibility. On MRI the inflammatory changes appeared as hyperintense areas on fat-saturated T2 fast-spin-echo (FSE) images and showed signal increase on fat-saturated T1 SE images after Gd-DTPA. With MR localization CT-guided bone biopsies yielded P. acnes in 8 patients. No bacteria could be isolated from the remaining 6 patients. Acute inflammatory bone changes in SAPHO syndrome are well localized by MRI. With MR localization, CT-guided bone biopsies offer a minimally invasive alternative to open surgery in the detection of. P. acnes leading to the institution of a specific antibiotic therapy. (orig.)

  13. Multi-temporal MRI carpal bone volumes analysis by principal axes registration

    Science.gov (United States)

    Ferretti, Roberta; Dellepiane, Silvana

    2016-03-01

    In this paper, a principal axes registration technique is presented, with the relevant application to segmented volumes. The purpose of the proposed registration is to compare multi-temporal volumes of carpal bones from Magnetic Resonance Imaging (MRI) acquisitions. Starting from the study of the second-order moment matrix, the eigenvectors are calculated to allow the rotation of volumes with respect to reference axes. Then the volumes are spatially translated to become perfectly overlapped. A quantitative evaluation of the results obtained is carried out by computing classical indices from the confusion matrix, which depict similarity measures between the volumes of the same organ as extracted from MRI acquisitions executed at different moments. Within the medical field, the way a registration can be used to compare multi-temporal images is of great interest, since it provides the physician with a tool which allows a visual monitoring of a disease evolution. The segmentation method used herein is based on the graph theory and is a robust, unsupervised and parameters independent method. Patients affected by rheumatic diseases have been considered.

  14. Analysis of Vibrant Soundbridge placement against the round window membrane in a human cadaveric temporal bone model.

    NARCIS (Netherlands)

    Pennings, R.J.E.; Ho, A.; Brown, J.; Wijhe, R.G. van; Bance, M.

    2010-01-01

    OBJECTIVE: To evaluate optimal placement of the Floating Mass Transducer of the Vibrant Soundbridge (Med-El, Innsbruck, Austria) against the round window membrane, particularly the impact of interposed coupling fascia and of covering materials. METHOD: : Six fresh human cadaveric temporal bones were

  15. Systemic Lupus Erythematosus and hearing disorders: Literature review and meta-analysis of clinical and temporal bone findings.

    Science.gov (United States)

    Di Stadio, Arianna; Ralli, Massimo

    2017-01-01

    Objective This literature review and meta-analysis was performed to evaluate the correlations among hearing and vestibular clinical symptoms, temporal bone findings, and pathological mechanisms in patients with systemic lupus erythematosus (SLE). Study design Relevant papers in the literature were retrospectively reviewed. Clinical hearing aspects in patients with SLE and relevant temporal bone studies in the same field were analyzed. Methods PubMed and Google Scholar searches were performed using the following keywords: "auto-immune disease," "systemic lupus erythematosus (SLE)," "hearing loss," "temporal bone study," "vertigo," "dizziness," "tinnitus," "ear symptoms," "treatment," "diagnosis," "symptoms," "etiopathogenesis," "Wegener granulomatosis," "Sjogren," "polyarteritis nodosa," "Cogan syndrome," and "granulomatosis." Also included were reviews in which the following terms were present: "SLE," "temporal bone," and "hearing symptoms." Review and conclusion This literature review and meta-analysis focused on the pathological mechanisms through which SLE can damage inner ear structures and determinate hearing and vestibular symptoms. The main mechanisms involved in inner ear damage include the autoimmune response, deposition of immune complexes in the vessels and, to a lesser extent, cytotoxic damage.

  16. Cochlear Implantation through the Middle Fossa Approach: A Review of Related Temporal Bone Studies and Reported Cases.

    Science.gov (United States)

    Lesser, Juan Carlos Cisneros; Brito Neto, Rubens Vuono de; Martins, Graziela de Souza Queiroz; Bento, Ricardo Ferreira

    2017-01-01

    Introduction Middle fossa approach has been suggested as an alternative for patients in whom other routes of electrode insertion are contraindicated. Even though there are temporal bone studies about the feasibility of introducing the cochlear implant through the middle fossa, until now, very few studies have described results when cochlear implant surgery is done through this approach. Objective The objective of this study is to review a series of temporal bone studies related to cochlear implantation through the middle fossa and the results obtained by different surgical groups after cochlear implantation through this approach. Data Sources PubMed, MD consult and Ovid-SP databases. Data Synthesis A total of 8 human cadaveric temporal bone studies and 6 studies reporting cochlear implant surgery through the middle fossa approach met the inclusion criteria. Temporal bone studies show that it is feasible to perform cochlear implantation through this route. So far, only two surgical groups have performed cochlear implantation through the middle fossa with a total of 15 implanted patients. One group entered the cochlea in the most upper part of the basal turn, inserting the implant in the direction of the middle and apical turns; meanwhile, the other group inserted the implant in the apical turn directed in a retrograde fashion to the middle and basal turns. Results obtained in both groups were similar. Conclusions The middle fossa approach is a good alternative for cochlear implantation when other routes of electrode insertion are contraindicated.

  17. Analysis of Vibrant Soundbridge placement against the round window membrane in a human cadaveric temporal bone model.

    NARCIS (Netherlands)

    Pennings, R.J.E.; Ho, A.; Brown, J.; Wijhe, R.G. van; Bance, M.

    2010-01-01

    OBJECTIVE: To evaluate optimal placement of the Floating Mass Transducer of the Vibrant Soundbridge (Med-El, Innsbruck, Austria) against the round window membrane, particularly the impact of interposed coupling fascia and of covering materials. METHOD: : Six fresh human cadaveric temporal bones were

  18. Efficient 3D rigid-body registration of micro-MR and micro-CT trabecular bone images

    Science.gov (United States)

    Rajapakse, C. S.; Magland, J.; Wehrli, S. L.; Zhang, X. H.; Liu, X. S.; Guo, X. E.; Wehrli, F. W.

    2008-03-01

    Registration of 3D images acquired from different imaging modalities such as micro-magnetic resonance imaging (µMRI) and micro-computed tomography (µCT) are of interest in a number of medical imaging applications. Most general-purpose multimodality registration algorithms tend to be computationally intensive and do not take advantage of the shape of the imaging volume. Multimodality trabecular bone (TB) images of cylindrical cores, for example, tend to be misaligned along and around the axial direction more than that around other directions. Additionally, TB images acquired by µMRI can differ substantially from those acquired by µCT due to apparent trabecular thickening from magnetic susceptibility boundary effects and non-linear intensity correspondence. However, they share very similar contrast characteristics since the images essentially represent a binary tomographic system. The directional misalignment and the fundamental similarities of the two types of images can be exploited to achieve fast 3D registration. Here we present an intensity cross-correlation based 3D registration algorithm for registering 3D specimen images from cylindrical cores of cadaveric TB acquired by µMRI and µCT in the context of finite-element modeling to assess the bone's mechanical constants. The algorithm achieves the desired registration by first coarsely approximating the three translational and three rotational parameters required to align the µMR images to the µCT scan coordinate frame and fine-tuning the parameters in the neighborhood of the approximate solution. The algorithm described here is suitable for 3D rigid-body image registration applications where through-plane rotations are known to be relatively small. The accuracy of the technique is constrained by the image resolution and in-plane angular increments used.

  19. A comparison of conventional maximum intensity projection with a new depth-specific topographic mapping technique in the CT analysis of proximal tibial subchondral bone density

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, James D. [University of Saskatchewan, Department of Mechanical Engineering, Saskatoon, SK (Canada); University of British Columbia, Department of Mechanical Engineering, Vancouver, BC (Canada); Kontulainen, Saija A. [University of Saskatchewan, College of Kinesiology, Saskatoon, SK (Canada); Masri, Bassam A.; Wilson, David R. [University of British Columbia, Department of Orthopaedics, Vancouver, BC (Canada)

    2010-09-15

    The objective was to identify subchondral bone density differences between normal and osteoarthritic (OA) proximal tibiae using computed tomography osteoabsorptiometry (CT-OAM) and computed tomography topographic mapping of subchondral density (CT-TOMASD). Sixteen intact cadaver knees from ten donors (8 male:2 female; mean age:77.8, SD:7.4 years) were categorized as normal (n = 10) or OA (n = 6) based upon CT reconstructions. CT-OAM assessed maximum subchondral bone mineral density (BMD). CT-TOMASD assessed average subchondral BMD across three layers (0-2.5, 2.5-5 and 5-10 mm) measured in relation to depth from the subchondral surface. Regional analyses of CT-OAM and CT-TOMASD included: medial BMD, lateral BMD, and average BMD of a 10-mm diameter area that searched each medial and lateral plateau for the highest ''focal'' density present within each knee. Compared with normal knees, both CT-OAM and CT-TOMASD demonstrated an average of 17% greater whole medial compartment density in OA knees (p < 0.016). CT-OAM did not distinguish focal density differences between OA and normal knees (p > 0.05). CT-TOMASD focal region analyses revealed an average of 24% greater density in the 0- to 2.5-mm layer (p = 0.003) and 36% greater density in the 2.5- to 5-mm layer (p = 0.034) in OA knees. Both CT-OAM and TOMASD identified higher medial compartment density in OA tibiae compared with normal tibiae. In addition, CT-TOMASD indicated greater focal density differences between normal and OA knees with increased depth from the subchondral surface. Depth-specific density analyses may help identify and quantify small changes in subchondral BMD associated with OA disease onset and progression. (orig.)

  20. Semiautomated three-dimensional segmentation software to quantify carpal bone volume changes on wrist CT scans for arthritis assessment.

    Science.gov (United States)

    Duryea, J; Magalnick, M; Alli, S; Yao, L; Wilson, M; Goldbach-Mansky, R

    2008-06-01

    Rapid progression of joint destruction is an indication of poor prognosis in patients with rheumatoid arthritis. Computed tomography (CT) has the potential to serve as a gold standard for joint imaging since it provides high resolution three-dimensional (3D) images of bone structure. The authors have developed a method to quantify erosion volume changes on wrist CT scans. In this article they present a description and validation of the methodology using multiple scans of a hand phantom and five human subjects. An anthropomorphic hand phantom was imaged with a clinical CT scanner at three different orientations separated by a 30-deg angle. A reader used the semiautomated software tool to segment the individual carpal bones of each CT scan. Reproducibility was measured as the root-mean-square standard deviation (RMMSD) and coefficient of variation (CoV) between multiple measurements of the carpal volumes. Longitudinal erosion progression was studied by inserting simulated erosions in a paired second scan. The change in simulated erosion size was calculated by performing 3D image registration and measuring the volume difference between scans in a region adjacent to the simulated erosion. The RMSSD for the total carpal volumes was 21.0 mm3 (CoV = 1.3%) for the phantom, and 44.1 mm3 (CoV = 3.0%) for the in vivo subjects. Using 3D registration and local volume difference calculations, the RMMSD was 1.0-3.0 mm3 The reader time was approximately 5 min per carpal bone. There was excellent agreement between the measured and simulated erosion volumes. The effect of a poorly measured volume for a single erosion is mitigated by the large number of subjects that would comprise a clinical study and that there will be many erosions measured per patient. CT promises to be a quantifiable tool to measure erosion volumes and may serve as a gold standard that can be used in the validation of other modalities such as magnetic resonance imaging.

  1. Usefulness of F-18 FDG PET/CT in a case of Kaposi sarcoma with an unexpected bone lesion.

    Science.gov (United States)

    Morooka, Miyako; Ito, Kimiteru; Kubota, Kazuo; Yanagisawa, Kunio; Teruya, Katsuji; Hasuo, Kahehiro; Shida, Yoshitaka; Minamimoto, Rhogo; Kikuchi, Yoshimi; Oka, Shinichi

    2011-03-01

    Bone lesions of Kaposi sarcoma are rare. A 56-year-old man who was HIV positive and was diagnosed with Kaposi sarcoma on the basis of the results of a biopsy of skin lesions, underwent F-18 FDG PET/CT scan for detecting Kaposi sarcoma lesions and other AIDS-related diseases. An abnormal uptake was observed in the lumbar spine. MRI showed a diffuse enhanced spine lesion, and Ga-67 and ²⁰¹Tl scanning were negative. As a result, the lesion was considered to be a Kaposi sarcoma, and the shrinkage of the lesion was noted after the therapy for Kaposi sarcoma.

  2. CT and MRI assessment and characterization using segmentation and 3D modeling techniques: applications to muscle, bone and brain

    Directory of Open Access Journals (Sweden)

    Paolo Gargiulo

    2014-03-01

    Full Text Available This paper reviews the novel use of CT and MRI data and image processing tools to segment and reconstruct tissue images in 3D to determine characteristics of muscle, bone and brain.This to study and simulate the structural changes occurring in healthy and pathological conditions as well as in response to clinical treatments. Here we report the application of this methodology to evaluate and quantify: 1. progression of atrophy in human muscle subsequent to permanent lower motor neuron (LMN denervation, 2. muscle recovery as induced by functional electrical stimulation (FES, 3. bone quality in patients undergoing total hip replacement and 4. to model the electrical activity of the brain. Study 1: CT data and segmentation techniques were used to quantify changes in muscle density and composition by associating the Hounsfield unit values of muscle, adipose and fibrous connective tissue with different colors. This method was employed to monitor patients who have permanent muscle LMN denervation in the lower extremities under two different conditions: permanent LMN denervated not electrically stimulated and stimulated. Study 2: CT data and segmentation techniques were employed, however, in this work we assessed bone and muscle conditions in the pre-operative CT scans of patients scheduled to undergo total hip replacement. In this work, the overall anatomical structure, the bone mineral density (BMD and compactness of quadriceps muscles and proximal femoral was computed to provide a more complete view for surgeons when deciding which implant technology to use. Further, a Finite element analysis provided a map of the strains around the proximal femur socket when solicited by typical stresses caused by an implant press fitting. Study 3 describes a method to model the electrical behavior of human brain using segmented MR images. The aim of the work is to use these models to predict the electrical activity of the human brain under normal and pathological

  3. CT and MRI Assessment and Characterization Using Segmentation and 3D Modeling Techniques: Applications to Muscle, Bone and Brain

    Science.gov (United States)

    Helgason, Thordur; Ramon, Ceon; jr, Halldór Jónsson; Carraro, Ugo

    2014-01-01

    This paper reviews the novel use of CT and MRI data and image processing tools to segment and reconstruct tissue images in 3D to determine characteristics of muscle, bone and brain. This to study and simulate the structural changes occurring in healthy and pathological conditions as well as in response to clinical treatments. Here we report the application of this methodology to evaluate and quantify: 1. progression of atrophy in human muscle subsequent to permanent lower motor neuron (LMN) denervation, 2. muscle recovery as induced by functional electrical stimulation (FES), 3. bone quality in patients undergoing total hip replacement and 4. to model the electrical activity of the brain. Study 1: CT data and segmentation techniques were used to quantify changes in muscle density and composition by associating the Hounsfield unit values of muscle, adipose and fibrous connective tissue with different colors. This method was employed to monitor patients who have permanent muscle LMN denervation in the lower extremities under two different conditions: permanent LMN denervated not electrically stimulated and stimulated. Study 2: CT data and segmentation techniques were employed, however, in this work we assessed bone and muscle conditions in the pre-operative CT scans of patients scheduled to undergo total hip replacement. In this work, the overall anatomical structure, the bone mineral density (BMD) and compactness of quadriceps muscles and proximal femoral was computed to provide a more complete view for surgeons when deciding which implant technology to use. Further, a Finite element analysis provided a map of the strains around the proximal femur socket when solicited by typical stresses caused by an implant press fitting. Study 3 describes a method to model the electrical behavior of human brain using segmented MR images. The aim of the work is to use these models to predict the electrical activity of the human brain under normal and pathological conditions by

  4. Osteonecrosis Mimicking Bone Metastasis in Femoral Head on {sup 18F} FDG PET/CT: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kyu Ho; Oh, Jin Kyoung; Kim, Sung Hoon; Yoo, Ik Dong; Choi, Eun Kyoung; Han, Eun Ji [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2011-03-15

    A 77 year old woman underwent chemotherapy, radiotherapy, and brachytherapy for cervical cancer 9 years ago. On a follow up {sup 18F} fluorodeoxyglucose (FDG) PET/CT image, focal FDG uptake was noted in a focal osteolytic lesion in the right femoral head. During magnetic resonance imaging, this lesion showed subchondral dark signal intensity rim on T1 weighted image and double line sign on T2 weighted image, suggestive of osteonecrosis. The lesion was pathologically confirmed as osteonecrosis after surgery. This case demonstrates that osteonecrosis of the femoral head may demonstrate focal FDG uptake mimicking bone metastasis.

  5. 11C-choline vs. 18F-FDG PET/CT in assessing bone involvement in patients with multiple myeloma

    Directory of Open Access Journals (Sweden)

    Ambrosini Valentina

    2007-06-01

    Full Text Available Abstract Background Multiple Myeloma (MM is a B cell neoplasm causing lytic or osteopenic bone abnormalities. Whole body skeletal survey (WBSS, Magnetic resonance (MR and 18F-FDG PET/CT are imaging techniques routinely used for the evaluation of bone involvement in MM patients. Aim As MM bone lesions may present low 18F-FDG uptake; the aim of this study was to assess the possible added value and limitations of 11C-Choline to that of 18F-FDG PET/CT in patients affected with MM. Methods Ten patients affected with MM underwent a standard 11C-Choline PET/CT and an 18F-FDG PET/CT within one week. The results of the two scans were compared in terms of number, sites and SUVmax of lesions. Results Four patients (40% had a negative concordant 11C-Choline and 18F-FDG PET/CT scans. Two patients (20% had a positive 11C-Choline and 18F-FDG PET/CT scans that identified the same number and sites of bone lesions. The remaining four patients (40% had a positive 11C-Choline and 18F-FDG PET/CT scan, but the two exams identified different number of lesions. Choline showed a mean SUVmax of 5 while FDG showed a mean SUVmax of 3.8 (P = 0.042. Overall, 11C-Choline PET/CT scans detected 37 bone lesions and 18F-FDG PET/CT scans detected 22 bone lesions but the difference was not significant (P = 0.8. Conclusion According to these preliminary data, 11C-Choline PET/CT appears to be more sensitive than 18F-FDG PET/CT for the detection of bony myelomatous lesions. If these data are confirmed in larger series of patients, 11C-Choline may be considered a more appropriate functional imaging in association with MRI for MM bone staging.

  6. Delayed loss of hearing after hearing preservation cochlear implantation: Human temporal bone pathology and implications for etiology.

    Science.gov (United States)

    Quesnel, Alicia M; Nakajima, Hideko Heidi; Rosowski, John J; Hansen, Marlan R; Gantz, Bruce J; Nadol, Joseph B

    2016-03-01

    After initially successful preservation of residual hearing with cochlear implantation, some patients experience subsequent delayed hearing loss. The etiology of such delayed hearing loss is unknown. Human temporal bone pathology is critically important in investigating the etiology, and directing future efforts to maximize long term hearing preservation in cochlear implant patients. Here we present the temporal bone pathology from a patient implanted during life with an Iowa/Nucleus Hybrid S8 implant, with initially preserved residual hearing and subsequent hearing loss. Both temporal bones were removed for histologic processing and evaluated. Complete clinical and audiologic records were available. He had bilateral symmetric high frequency severe to profound hearing loss prior to implantation. Since he was implanted unilaterally, the unimplanted ear was presumed to be representative of the pre-implantation pathology related to his hearing loss. The implanted and contralateral unimplanted temporal bones both showed complete degeneration of inner hair cells and outer hair cells in the basal half of the cochleae, and only mild patchy loss of inner hair cells and outer hair cells in the apical half. The total spiral ganglion neuron counts were similar in both ears: 15,138 (56% of normal for age) in the unimplanted right ear and 13,722 (51% of normal for age) in the implanted left ear. In the basal turn of the implanted left cochlea, loose fibrous tissue and new bone formation filled the scala tympani, and part of the scala vestibuli. Delayed loss of initially preserved hearing after cochlear implantation was not explained by additional post-implantation degeneration of hair cells or spiral ganglion neurons in this patient. Decreased compliance at the round window and increased damping in the scala tympani due to intracochlear fibrosis and new bone formation might explain part of the post-implantation hearing loss. Reduction of the inflammatory and immune response to

  7. [The potential of cone beam computed tomography of the temporal bones in the patients presenting with otosclerosis].

    Science.gov (United States)

    Karpishchenko, S A; Zubareva, A A; Filimonov, V N; Shavgulidze, M A; Azovtseva, E A

    The objective of the present study was to analyze the potential of cone beam computed tomography of the temporal bones in the patients presenting with otosclerosis for the detection of surgically significant specific structural features of the labyrinth wall of the tympanic cavity. More than 400 tomograms of the temporal bones were obtained with the use of a cone beam tomographwere available for the investigation during the period from 2012 till 2016. The study was carried out in several steps, viz. the search for the optimal (for the given instrument) position of the patient, the experimental stage, the retrospective analysis of the tomograms and the comparison of the temporal bones of different types (pneumatic, mixed, and sclerotic) in individual patients, the comparison of the results of cone beam computed tomography (CBCT) with the intraoperative observations, and the modification of the algorithm for the analysis of temporal bone cone beam tomograms. The study included a total of 16 patients (15 women at the age from 32 to 56 years and one managed 58 years) presenting with the clinical diagnosis of otosclerosis. The results of the study were used to elaborate the algorithm for the analysis of cone beam tomograms of the temporal bones to be performed inthe stage by stage manner including the qualitative analysis of tomograms, evaluation of their quantitative parameters and additional characteristics to be taken into consideration when planning the surgical interventions on the labyrinth wall and the tympanic cavity as a preparation for the stapedoplastic treatment. The results of CBCT obtained in the present study were compared with the surgical observations. The diagnostic sensitivity and specificity of the method were estimated to be 100% and 83% respectively. It is concluded that cone beam computed tomography can be employed as a component of the diagnostic algorithm prior to the planning of surgical interventions onthe medial wall of the tympanic cavity

  8. COCHLEAR LENGTH DETERMINATION IN TEMPORAL BONE SPECIMENS USING HISTOLOGICAL SERIAL MICRO GRINDING IMAGING, MICRO COMPUTED TOMOGRAPHY AND FLAT-PANEL VOLUMETRIC COMPUTED TOMOGRAPHY

    Directory of Open Access Journals (Sweden)

    Waldemar Würfel

    2015-04-01

    Full Text Available The cochlear length virtually describes the length of the cochlea in a straight line. Several theoretical options for measuring the length of the cochlea are conceivable. In choosing the type of cochlear implant electrode, this can play a crucial role. A wide range of electrodes is available, especially among the models designed to preserve residual hearing and structural integrity. It is believed that the depth of cochlear implant electrode insertion has an influence on the functional hearing based on the area of the cochlea that is electrically stimulated. Method: Imaging of nine human temporal bone specimens was performed using histological serial microgrinding imaging, micro computed tomography (microCT and experimental flat-panel volumetric computed tomography (fpVCT. Measurements were then performed by outlining the cochlea in OsiriX (Pixmeo, Los Angeles USA. Results: The cochlear length of 9 human temporal bones was determined in each histological serial microgrinding imaging, fpVCT and microCT. Cochlear length ranges in histological serial grinding imaging from 45.3 mm to 38.7 mm, in microCT from 46.1 mm to 39.3 mm and in fpVCT from 45.8 mm to 39.8 mm. Significant inter- and intraindividual differences in the cochlear length were observed. The presented methodology is capable of determining the cochlear length in each imaging modality. Discussion: A methodology to experimentally determine the cochlear length is interesting from both clinical and preclinical perspectives. Insertion studies are highly relevant to the development and evaluation of new electrode arrays. This study presents a measurement methodology that allows for individualized cochlear length measurement based on three established imaging modalities. The data presented here confirm differences in cochlear length. The method described here can be used to evaluate a cochlea in an experimental setting. This allows an individualized, pre-interventional evaluation of the

  9. CT perfusion assessment of Moyamoya syndrome before and after direct revascularization (superficial temporal artery to middle cerebral artery bypass)

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yueqin [Hospital of Qingdao University, Department of Radiology, Qingdao (China); Hospital of Jining Medical College, CT Department, Jining (China); Xu, Wenjian [Hospital of Qingdao University, Department of Radiology, Qingdao (China); Guo, Xiang; Shi, Zhitao; Sun, Zhanguo; Wang, Jiehuan [Hospital of Jining Medical College, CT Department, Jining (China); Gao, Lingyun [Hospital of Jining Medical College, MR Department, Jining (China); Jin, Feng [Hospital of Jining Medical College, Department of Neurosurgery, Jining (China); Chen, Weijian; Yang, Yunjun [Hospital of Wenzhou Medical University, Department of Radiology, Wenzhou (China)

    2016-01-15

    To evaluate the utility of CT perfusion (CTP) for the assessment of superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis in patients with Moyamoya syndrome (MMS). Twenty-four consecutive MMS patients, who underwent unilateral STA-MCA bypass surgery, received CTP before and after surgery. The relative perfusion parameter values of surgical hemispheres before treatment were compared with post-treatment values. All patients underwent CT angiography (CTA) before and after surgery in order to confirm the patency of bypass. The follow-up CTA after surgery clearly demonstrated 20 (20/24, 83.3 %) bypass arteries, whereas four (16.7 %) bypass arteries were occluded or very small. Postoperative rMTT and rTTP values (P < 0.05) of the surgical side were significantly lower than pre-operation. In patients (n = 20) with bypass patency, postoperative rCBF, rMTT and rTTP values (P < 0.05) of the surgical side were significantly improved. However, the differences of all parameters were not significant (P > 0.05) in the patients (n = 4) without bypass patency after revascularization. This study demonstrates that CTP can provide a crucial quantitative assessment of cerebral haemodynamic changes in MMS before and after STA-MCA anastomosis. (orig.)

  10. Improved detection of bone metastases from lung cancer in the thoracic cage using 5- and 1-mm axial images versus a new CT software generating rib unfolding images: comparison with standard ¹⁸F-FDG-PET/CT.

    Science.gov (United States)

    Homann, Georg; Mustafa, Deedar F; Ditt, Hendrik; Spengler, Werner; Kopp, Hans-Georg; Nikolaou, Konstantin; Horger, Marius

    2015-04-01

    To evaluate the performance of a dedicated computed tomography (CT) software called "bone reading" generating rib unfolded images for improved detection of rib metastases in patients with lung cancer in comparison to readings of 5- and 1-mm axial CT images and (18)F-Fluordeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT). Ninety consecutive patients who underwent (18)F-FDG-PET/CT and chest CT scanning between 2012 and 2014 at our institution were analyzed retrospectively. Chest CT scans with 5- and 1-mm slice thickness were interpreted blindly and separately focused on the detection of rib metastases (location, number, cortical vs. medullary, and osteoblastic vs. sclerotic). Subsequent image analysis of unfolded 1 mm-based CT rib images was performed. For all three data sets the reading time was registered. Finally, results were compared to those of FDG-PET. Validation was based on FDG-PET positivity for osteolytic and mixed osteolytic/osteoblastic focal rib lesions and follow-up for sclerotic PET-negative lesions. A total of 47 metastatic rib lesions were found on FDG-PET/CT plus another 30 detected by CT bone reading and confirmed by follow-up CT. Twenty-nine lesions were osteolytic, 14 were mixed osteolytic/osteoblastic, and 34 were sclerotic. On a patient-based analysis, CT (5 mm), CT (1 mm), and CT (1-mm bone reading) yielded a sensitivity, specificity, and accuracy of 76.5/97.3/93, 81.3/97.3/94, and 88.2/95.9/92, respectively. On segment-based (unfolded rib) analysis, the sensitivity, specificity, and accuracy of the three evaluations were 47.7/95.7/67, 59.5/95.8/77, and 94.8/88.2/92, respectively. Reading time for 5 mm/1 mm axial images and unfolded images was 40.5/50.7/21.56 seconds, respectively. The use of unfolded rib images in patients with lung cancer improves sensitivity and specificity of rib metastasis detection in comparison to 5- and 1-mm CT slice reading. Moreover, it may reduce the reading time. Copyright © 2015 AUR

  11. Temporal variation and lack of host specificity among bacterial endosymbionts of Osedax bone worms (Polychaeta: Siboglinidae

    Directory of Open Access Journals (Sweden)

    Salathé Rahel M

    2012-09-01

    Full Text Available Abstract Background Osedax worms use a proliferative root system to extract nutrients from the bones of sunken vertebrate carcasses. The roots contain bacterial endosymbionts that contribute to the nutrition of these mouthless and gutless worms. The worms acquire these essential endosymbionts locally from the environment in which their larvae settle. Here we report on the temporal dynamics of endosymbiont diversity hosted by nine Osedax species sampled during a three-year investigation of an experimental whale fall at 1820-m depth in the Monterey Bay, California. The host species were identified by their unique mitochondrial COI haplotypes. The endosymbionts were identified by ribotyping with PCR primers specifically designed to target Oceanospirillales. Results Thirty-two endosymbiont ribotypes associated with these worms clustered into two distinct bacterial ribospecies that together comprise a monophyletic group, mostly restricted to deep waters (>1000 m. Statistical analyses confirmed significant changes in the relative abundances of host species and the two dominant endosymbiont ribospecies during the three-year sampling period. Bone type (whale vs. cow also had a significant effect on host species, but not on the two dominant symbiont ribospecies. No statistically significant association existed between the host species and endosymbiont ribospecies. Conclusions Standard PCR and direct sequencing proved to be an efficient method for ribotyping the numerically dominant endosymbiont strains infecting a large sample of host individuals; however, this method did not adequately represent the frequency of mixed infections, which appears to be the rule rather than an exception for Osedax individuals. Through cloning and the use of experimental dilution series, we determined that minority ribotypes constituting less than 30% of a mixture would not likely be detected, leading to underestimates of the frequency of multiple infections in host

  12. Is 3D-CT reformation using free software applicable to diagnosis of bone changes in mandibular condyles?

    Directory of Open Access Journals (Sweden)

    Marília Gerhardt de Oliveira

    2009-06-01

    Full Text Available OBJECTIVES: This study evaluated the agreement of computed tomography (CT imaging using 3D reformations (3DR with shaded surface display (SSD and maximum intensity projection (MIP in the diagnosis of bone changes in mandibular condyles of patients with rheumatoid arthritis (RA, and compared findings with multiplanar reformation (MPR images, used as the criterion standard. MATERIAL AND METHODS: Axial CT images of 44 temporomandibular joints (TMJs of 22 patients with RA were used. Images were recorded in DICOM format and assessed using free software (ImageJ. Each sample had its 3DR-SSD and 3DR-MIP results compared in pairs with the MPR results. RESULTS: Slight agreement (k = 0.0374 was found in almost all comparisons. The level of agreement showed that 3DR-SSD and 3DR-MIP yielded a number of false-negative results that was statistically significant when compared with MPR. CONCLUSIONS: 3DR-SSD or 3DR-MIP should only be used as adjuvant techniques to MPR in the diagnosis of bone changes in mandibular condyles.

  13. Complementary roles of tumour specific PET tracer {sup 18}F-FAMT to {sup 18}F-FDG PET/CT for the assessment of bone metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Motoho [Gunma University Hospital, Department of General Medicine, Maebashi, Gunma (Japan); Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi, Gunma (Japan); Higuchi, Tetsuya; Tokue, Azusa; Arisaka, Yukiko; Tsushima, Yoshito [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi, Gunma (Japan); Achmad, Arifudin [Gunma University Graduate School of Medicine, Department of Diagnostic Radiology and Nuclear Medicine, Maebashi, Gunma (Japan); Gadjah Mada University, Department of Radiology, Faculty of Medicine, Yogyakarta (Indonesia)

    2013-10-15

    The usefulness of {sup 18}F-FDG PET/CT for bone metastasis evaluation has already been established. The amino acid PET tracer [{sup 18}F]-3-fluoro-alpha-methyl tyrosine ({sup 18}F-FAMT) has been reported to be highly specific for malignancy. We evaluated the additional value of {sup 18}F-FAMT PET/CT to complement {sup 18}F-FDG PET/CT in the evaluation of bone metastasis. This retrospective study included 21 patients with bone metastases of various cancers who had undergone both {sup 18}F-FDG and {sup 18}F-FAMT PET/CT within 1 month of each other. {sup 18}F-FDG-avid bone lesions suspicious for malignancy were carefully selected based on the cut-off value for malignancy, and the SUVmax of the {sup 18}F-FAMT in the corresponding lesions were evaluated. A total of 72 {sup 18}F-FDG-positive bone lesions suspected to be metastases in the 21 patients were used as the reference standard. {sup 18}F-FAMT uptake was found in 87.5 % of the lesions. In the lesions of lung cancer origin, the uptake of the two tracers showed a good correlation (40 lesions, r = 0.68, P < 0.01). Bone metastatic lesions of oesophageal cancer showed the highest average of {sup 18}F-FAMT uptake. Bone metastatic lesions of squamous cell carcinoma showed higher {sup 18}F-FAMT uptake than those of adenocarcinoma. No significant difference in {sup 18}F-FAMT uptake was seen between osteoblastic and osteolytic bone metastatic lesions. The usefulness of {sup 18}F-FAMT PET/CT for bone metastasis detection regardless of the lesion phenotype was demonstrated. The fact that {sup 18}F-FAMT uptake was confirmed by {sup 18}F-FDG uptake suggests that {sup 18}F-FAMT PET/CT has the potential to complement {sup 18}F-FDG PET/CT for the detection of bone metastases. (orig.)

  14. Patología del hueso temporal en pediatría: hallazgos tomográficos característicos Pediatric pathology of temporal bone: characteristic tomographic findings

    Directory of Open Access Journals (Sweden)

    Paola Berra

    2012-06-01

    Full Text Available El hueso temporal es asiento de patologías otológicas frecuentes en Pediatría. Objetivo. Realizar una evaluación estadística y la descripción de los hallazgos tomográficos característicos de la patología del hueso temporal en una población pediátrica. Materiales y Métodos. Trabajo retrospectivo, longitudinal y descriptivo de una revisión de 64 historias clínicas, realizadas entre enero de 2008 y abril de 2011 en el Hospital de Pediatría "Pedro Elizalde". La clasificación de las patologías se dividió en: inflamatoria (infecciosa y no infecciosa, congénita, histiocitosis, infiltración tumoral y traumática. Resultados. Sexo masculino: 64%; rango etario: de 1 mes a 14 años (media: 6,1 años. Se encontró patología inflamatoria infecciosa en el 53% de los pacientes, patología inflamatoria no infecciosa en el 36%, congénita en el 4,6 %, histiocitosis en el 1,5%, infiltración tumoral en el 3% y traumática en el 1,5%. Predominó la patología infecciosa en los menores de 5 años (otomastoiditis: 43,6%. El colesteatoma constituyó la patología inflamatoria no infecciosa más común en el rango etario de 6 a 14 años (36%. No se presentaron lesiones neoplásicas propias, sino por infiltración tumoral (fibroangioma nasofaríngeo y metástasis de neuroblastoma. Conclusión. La otomastoiditis aguda y el colesteatoma constituyen la patología otológica más frecuente en Pediatría y requieren la realización de una Tomografía Computada (TC. En los casos revisados, el diagnóstico tomográfico coincidió con el clínico-quirúrgico y/o anatomopatológico.The temporal bone is the seat of frequent otologic disorders in children. Objective. To report the statistics and description of characteristic computed tomography (CT findings of temporal bone pathology in a pediatric population. Material and Methods. Retrospective, longitudinal and descriptive review of 64 medical records taken between January 2008 and April 2011 at the

  15. Evaluating differential nuclear DNA yield rates and osteocyte numbers among human bone tissue types: A synchrotron radiation micro-CT approach.

    Science.gov (United States)

    Andronowski, Janna M; Mundorff, Amy Z; Pratt, Isaac V; Davoren, Jon M; Cooper, David M L

    2017-05-01

    Molecular human identification has conventionally focused on DNA sampling from dense, weight-bearing cortical bone tissue, typically from femora or tibiae. A comparison of skeletal elements from three contemporary individuals demonstrated that elements with high quantities of cancellous bone yielded nuclear DNA at the highest rates, suggesting that preferentially sampling cortical bone may be suboptimal (Mundorff & Davoren, 2014). Despite these findings, the reason for the differential DNA yields between cortical and cancellous bone tissues remains unknown. The primary goal of this work is to ascertain whether differences in bone microstructure can be used to explain differential nuclear DNA yield among bone tissue types observed by Mundorff and Davoren (2014), with a focus on osteocytes and the three-dimensional (3D) quantification of their associated lacunae. Osteocytes and other bone cells are recognized to house DNA in bone tissue, thus examining the density of their lacunae may explain why nuclear DNA yield rates differ among bone tissue types. Lacunae were visualized and quantified using synchrotron radiation-based micro-Computed Tomographic imaging (SR micro-CT). Volumes of interest (VOIs) from cortical and cancellous bone tissues (n=129) were comparatively analyzed from the three skeletons sampled for Mundorff and Davoren's (2014) study. Analyses tested the primary hypothesis that the abundance and density of osteocytes (inferred from their lacunar spaces) vary between cortical and cancellous bone tissue types. Results demonstrated that osteocyte lacunar abundance and density vary between cortical and cancellous bone tissue types, with cortical bone VOIs containing a higher lacunar abundance and density. We found that the osteocyte lacunar density values are independent of nuclear DNA yield, suggesting an alternative explanation for the higher nuclear DNA yields from bones with greater quantities of cancellous bone tissue. The use of SR micro-CT allowed for

  16. Temporal bone studies of the human peripheral vestibular system. Aminoglycoside ototoxicity.

    Science.gov (United States)

    Tsuji, K; Velázquez-Villaseñor, L; Rauch, S D; Glynn, R J; Wall, C; Merchant, S N

    2000-05-01

    Quantitative assessments of vestibular hair cells and Scarpa's ganglion cells were performed on 17 temporal bones from 10 individuals who had well-documented clinical evidence of aminoglycoside ototoxicity (streptomycin, kanamycin, and neomycin). Assessment of vestibular hair cells was performed by Nomarski (differential interference contrast) microscopy. Hair cell counts were expressed as densities (number of cells per 0.01 mm2 surface area of the sensory epithelium). The results were compared with age-matched normal data. Streptomycin caused a significant loss of both type I and type II hair cells in all 5 vestibular sense organs. In comparing the ototoxic effect on type I versus type II hair cells, there was greater type I hair cell loss for all 3 cristae, but not for the maculae. The vestibular ototoxic effects of kanamycin appeared to be similar to those of streptomycin, but the small sample size precluded definitive conclusions from being made. Neomycin did not cause loss of vestibular hair cells. Within the limits of this study (maximum postototoxicity survival time of 12 months), there was no significant loss of Scarpa's ganglion cells for any of the 3 drugs. The findings have implications in several clinical areas, including the correlation of vestibular test results to pathological findings, the rehabilitation of patients with vestibular ototoxicity, the use of aminoglycosides to treat Meniere's disease, and the development of a vestibular prosthesis.

  17. The new mid-scala electrode array: a radiologic and histologic study in human temporal bones.

    Science.gov (United States)

    Hassepass, Frederike; Bulla, Stefan; Maier, Wolfgang; Laszig, Roland; Arndt, Susan; Beck, Rainer; Traser, Lousia; Aschendorff, Antje

    2014-09-01

    To analyze the quality of insertion of the newly developed midscala (MS) electrode, which targets a midscalar electrode position to reduce the risk of trauma to the lateral wall and the modiolus. Modern cochlear implant surgery aims for a safe intracochlear placement of electrode arrays with an ongoing debate regarding cochleostomy or round window (RW) insertion and the use of lateral wall or perimodiolar electrode placement. Intracochlear trauma after insertion of different electrodes depends on insertion mode and electrode design and may result in trauma to the delicate structures of the cochlear. We performed a temporal bone (TB) trial with insertion of the MS electrode in n = 20 TB's after a mastoidectomy and posterior tympanotomy. Insertion was performed either via the RW or a cochleostomy. Electrode positioning, length of insertion, and angle of insertion were analyzed with rotational tomography (RT). TBs were histologically analyzed. Results of RT and histology were compared. Scala tympani (ST) insertion could be accomplished reliably by both RW and via a cochleostomy approach. In 20 TBs, 1 scala vestibuli insertion, 1 incomplete (ST), and 1 elevation of basilar membrane were depicted. No trauma was found in 94.7% of all ST insertions. RT allowed determination of the intracochlear electrode position, which was specified by histologic sectioning. The new MS electrode seems to fulfill reliable atraumatic intracochlear placement via RW and cochleostomy approaches. RT is available for evaluation of intracochlear electrode position, serving as a potential quality control instrument in human implantation.

  18. A 3-D analysis of the protympanum in human temporal bones with chronic ear disease.

    Science.gov (United States)

    Pauna, Henrique F; Monsanto, Rafael C; Schachern, Patricia; Paparella, Michael M; Cureoglu, Sebahattin

    2017-03-01

    Eustachian tube dysfunction is believed to be an important factor to cholesteatoma development and recurrence of disease after surgical treatment. Although many studies have described prognostic factors, evaluation methods, or surgical techniques for Eustachian tube dysfunction, they relied on the soft tissues of its structure; little is known about its bony structure-the protympanum-which connects the Eustachian tube to the tympanic cavity, and can also be affected by several inflammatory conditions, both from the middle ear or from the nasopharynx. We studied temporal bones from patients with cholesteatoma, chronic otitis media (with and without retraction pockets), purulent otitis media, and non-diseased ears, looking for differences between the volume of the protympanum, the diameter of the Eustachian tube isthmus, and the distance between the anterior tympanic annulus and the promontory. Light microscopy and 3-D reconstruction software were used for the measurements. We observed a decrease of volume in the lumen of the four middle ear diseased ears compared to the control group. We observed a significant decrease in the volume of the protympanic space in the cholesteatoma group compared to the chronic otitis media group. We also observed a decrease in the bony space (protympanum space) in cholesteatoma, chronic otitis media with retraction pockets, and purulent otitis media compared to the control group. We found a correlation in middle ear diseases and a decrease in the middle ear space. Our findings may suggest that a smaller bony volume in the protympanic area may trigger middle ear dysventilation problems.

  19. Differential Intracochlear Sound Pressure Measurements in Human Temporal Bones with an Off-the-Shelf Sensor.

    Science.gov (United States)

    Grossöhmichen, Martin; Salcher, Rolf; Püschel, Klaus; Lenarz, Thomas; Maier, Hannes

    2016-01-01

    The standard method to determine the output level of acoustic and mechanical stimulation to the inner ear is measurement of vibration response of the stapes in human cadaveric temporal bones (TBs) by laser Doppler vibrometry. However, this method is reliable only if the intact ossicular chain is stimulated. For other stimulation modes an alternative method is needed. The differential intracochlear sound pressure between scala vestibuli (SV) and scala tympani (ST) is assumed to correlate with excitation. Using a custom-made pressure sensor it has been successfully measured and used to determine the output level of acoustic and mechanical stimulation. To make this method generally accessible, an off-the-shelf pressure sensor (Samba Preclin 420 LP, Samba Sensors) was tested here for intracochlear sound pressure measurements. During acoustic stimulation, intracochlear sound pressures were simultaneously measurable in SV and ST between 0.1 and 8 kHz with sufficient signal-to-noise ratios with this sensor. The pressure differences were comparable to results obtained with custom-made sensors. Our results demonstrated that the pressure sensor Samba Preclin 420 LP is usable for measurements of intracochlear sound pressures in SV and ST and for the determination of differential intracochlear sound pressures.

  20. The Value of SPECT/CT in Monitoring Prefabricated Tissue-Engineered Bone and Orthotopic rhBMP-2 Implants for Mandibular Reconstruction.

    Directory of Open Access Journals (Sweden)

    Miao Zhou

    Full Text Available Bone tissue engineering shows good prospects for mandibular reconstruction. In recent studies, prefabricated tissue-engineered bone (PTEB by recombinant human bone morphogenetic proteins (rhBMPs applied in vivo has found to be an effective alternative for autologous bone grafts. However, the optimal time to transfer PTEB for mandibular reconstruction is still not elucidated. Thus, here in an animal experiment of rhesus monkey, the suitable transferring time for PTEB to reconstruct mandibular defects was evaluated by 99mTc-MDP SPECT/CT, and its value in monitoring orthotopic rhBMP-2 implants for mandibular reconstruction was also evaluated. The result of SPECT/CT showed higher 99mTc-MDP uptake, indicating osteoinductivity, in rhBMP-2 incorporated demineralized freeze-dried bone allograft (DFDBA and coralline hydroxyapatite (CHA implants than those without BMP stimulation. 99mTc-MDP uptake of rhBMP-2 implant peaked at 8 weeks following implantation while CT showed the density of these implants increased after 13 weeks' prefabrication. Histology confirmed that mandibular defects were repaired successfully with PTEB or orthotopically rhBMP-2 incorporated CHA implants, in accordance with SPECT/CT findings. Collectively, data shows 99mTc-MDP SPECT/CT is a sensitive and noninvasive tool to monitor osteoinductivity and bone regeneration of PTEB and orthotopic implants. The PTEB achieved peak osteoinductivity and bone density at 8 to 13 weeks following ectopic implantation, which would serve as a recommendable time frame for its transfer to mandibular reconstruction.

  1. Role of {sup 18}F-FDG PET/CT in the assessment of bone involvement in newly diagnosed multiple myeloma: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Nanni, Cristina; Farsad, Mohsen; Castellucci, Paolo; Fanti, Stefano [Policlinico S.Orsola-Malpighi, UO Medicina Nucleare, Bologna (Italy); Zamagni, Elena; Tosi, Patrizia; Cangini, Delia; Cavo, Michele [Policlinico S.Orsola-Malpighi, Istituto di Ematologia, Bologna (Italy); Salizzoni, Eugenio; Canini, Romeo [Policlinico S.Orsola-Malpighi, Istituto di Radiologia, Bologna (Italy)

    2006-05-15

    Purpose Multiple myeloma (MM) is a malignant B cell and plasma cell disorder which involves the skeleton in more than 80% of patients at diagnosis. The aim of this study was to compare whole-body X-ray (WBXR), MRI and {sup 18}F-FDG PET/CT in patients with MM. Methods The study population comprised 28 newly diagnosed MM patients. Findings of {sup 18}F-FDG PET/CT were compared with those of WBXR and MRI with regard to the number and site of lesions detected. Results Comparing 18F-FDG PET/CT and WBXR, it was found that in 16/28 pts (57%) {sup 18}F-FDG PET/CT detected more lesions, all of which were located in the skeleton. Nine of these 16 patients had a completely negative WBXR survey. In 12/28 pts (43%) the two methods yielded equivalent findings. Comparing {sup 18}F-FDG PET/CT and MRI, it was found that in 7/28 pts (25%), {sup 18}F-FDG PET/CT detected more lytic bone lesions, all of which were located outside the field of view of MRI (bone lesions in six cases and a soft tissue lesion in one). In 14/28 pts (50%), {sup 18}F-FDG PET/CT and MRI detected the same number of lesions in the spine and pelvis, while in 7/28 pts (25%) MRI detected an infiltrative pattern in the spine whereas {sup 18}F-FDG PET/CT was negative. Conclusion {sup 18}F-FDG PET/CT appears to be more sensitive than WBXR for the detection of small lytic bone lesions, whereas it has the same sensitivity as MRI in detecting bone disease of the spine and pelvis. On the other hand, MRI may be superior to 18F-FDG PET/CT in diagnosing an infiltrative pattern in the spine. Therefore, careful evaluation of MM bone disease at diagnosis should include both MRI of the spine and {sup 18}F-FDG PET/CT.

  2. Spontaneous osteo-dural fistulae of petrous bone posterior wall.

    Science.gov (United States)

    Junet, P; Bertolo, A; Schmerber, S

    2013-12-01

    To raise awareness of the possibility of spontaneous temporal bone cerebrospinal fistula in case of clear retrotympanic effusion. A 63-year-old man with no particular history presented with unilateral spontaneous right retrotympanic clear effusion. CT found defects in the posterior part of the right temporal bone, in contact with arachnoid granulations, with no other visible abnormalities. Unilateral clear retrotympanic effusion in an adult subject should, apart from serous otitis media, suggest possible cerebrospinal fistula. In the absence of otologic or traumatic history, arachnoid granulation is one possible etiology, inducing spontaneous cerebrospinal fluid leakage when facing the temporal bone. Diagnosis is suggested by bone defects in the tegmen tympani or posterior wall of the temporal bone on CT, with the adjacent mastoid cavities filled with fluid. Pneumococcal vaccination and early surgical repair of the fistula should be performed to avoid neuromeningeal infection. Copyright © 2013. Published by Elsevier Masson SAS.

  3. Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method

    Energy Technology Data Exchange (ETDEWEB)

    Jia Xun; Tian Zhen; Lou Yifei; Sonke, Jan-Jakob; Jiang, Steve B. [Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037 (United States); School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia 30318 (United States); Department of Radiation Oncology, Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Center for Advanced Radiotherapy Technologies and Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, California 92037 (United States)

    2012-09-15

    Purpose: Four-dimensional cone beam computed tomography (4D-CBCT) has been developed to provide respiratory phase-resolved volumetric imaging in image guided radiation therapy. Conventionally, it is reconstructed by first sorting the x-ray projections into multiple respiratory phase bins according to a breathing signal extracted either from the projection images or some external surrogates, and then reconstructing a 3D CBCT image in each phase bin independently using FDK algorithm. This method requires adequate number of projections for each phase, which can be achieved using a low gantry rotation or multiple gantry rotations. Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. 4D-CBCT images at different breathing phases share a lot of redundant information, because they represent the same anatomy captured at slightly different temporal points. Taking this redundancy along the temporal dimension into account can in principle facilitate the reconstruction in the situation of inadequate number of projection images. In this work, the authors propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. Methods: The authors define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms implementation on

  4. The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images

    Energy Technology Data Exchange (ETDEWEB)

    Roh, Yang Gyun; Jang, Hyun Seon; Kim, Byung Ock; Kim, Jin Soo [Chosun Univ. College of Dentistry, Gwangju (Korea, Republic of)

    2006-09-15

    To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Study materials included 38