  1. Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement

    Directory of Open Access Journals (Sweden)

    Afshin Akbarzadeh

    2009-06-01

    Full Text Available Introduction: One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter correction techniques. Empirical methods based on blocking the primary photons in a small region are not able to extract scatter in all elements of the detector array while the scatter profile is required for a scatter correction procedure. In this study, we measured scatter profiles in 64 slice CT scanners using a new experimental measurement. Material and Methods: To measure the scatter profile, a lead block array was inserted under the collimator and the phantom was exposed at the isocenter. The raw data file, which contained detector array readouts, was transferred to a PC and was read using a dedicated GUI running under MatLab 7.5. The scatter profile was extracted by interpolating the shadowed area. Results: The scatter and SPR profiles were measured. Increasing the tube voltage from 80 to 140 kVp resulted in an 80% fall off in SPR for a water phantom (d=210 mm and 86% for a polypropylene phantom (d = 350 mm. Increasing the air gap to 20.9 cm caused a 30% decrease in SPR. Conclusion: In this study, we presented a novel approach for measurement of scattered radiation distribution and SPR in a CT scanner with 64-slice capability using a lead block array. The method can also be used on other multi-slice CT scanners. The proposed technique can accurately estimate scatter profiles. It is relatively straightforward, easy to use, and can be used for any related measurement.

  2. Poster — Thur Eve — 02: Measurement of CT radiation profile width using Fuji CR imaging plate raw data

    International Nuclear Information System (INIS)

    Bjarnason, T A; Yang, C J

    2014-01-01

    Measuring the CT collimation width and assessing the shape of the overall profile is a relatively straightforward quality control (QC) measure that impacts both image quality and patient dose, and is often required at acceptance and routine testing. Most CT facilities have access to computed radiography (CR) systems, so performing CT collimation profile assessments using CR plates requires no additional equipment. Previous studies have shown how to effectively use CR plates to measure the radiation profile width. However, a major limitation of the previous work is that the full dynamic range of CR detector plates are not used, since the CR processing technology reduces the dynamic range of the DICOM output to 2 10 , requiring the sensitivity and latitude settings of CR reader to be adjusted to prevent clipping of the CT profile data. Such adjustments to CR readers unnecessarily complicate the QC procedure. These clipping artefacts hinder the ability to accurately assess CT collimation width because the full-width at half maximum value of the penumbras are not properly determined if the maximum dose of the profile is not available. Furthermore, any inconsistencies in the radiation profile shape are lost if the profile plateau is clipped off. In this work we developed an opensource Matlab script for straightforward CT profile width measurements using raw CR data that also allows assessment of the profile shape without clipping, and applied this approach during CT QC

  3. Spectral backward radiation profile

    International Nuclear Information System (INIS)

    Kwon, Sung Duck; Lee, Keun Hyun; Kim, Bo Ra; Yoon, Suk Soo

    2004-01-01

    Ultrasonic backward radiation profile is frequency-dependent when incident region has deptional gradient of acoustical properties or multi-layers. Until now, we have measured the profiles of principal frequencies of used transducers so that it was not easy to understand the change of the frequency component and spectrum of backward radiation from the profile. We tried to measure the spectral backward radiation profiles using DFP(digital filer package) Lecroy DSO. The very big changes in the shape and pattern of spectral backward radiation profiles leads to the conclusion that this new try could be very effective tool to evaluate frequency dependent surface area.

  4. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  5. Monitoring of radiation via CT

    International Nuclear Information System (INIS)

    Atzinger, A.; Pfaendner, K.; Gfirtner, H.; Hoetzinger, H.

    1981-01-01

    The results presented in this article lead to the conclusion that it would be appropriate to demand control or monitoring of radiation via CT whenever complicated exposure to radiation is required. Such control appears mandatory in order to guarantee a sufficiently high tumour dosage and satisfactory protection or minimum burdening of the surrounding tissue. At first sight, it may seem that such CT operations are relatively costly. However, once the teamwork has been properly established, both the time required and the cost involved remain within reasonable limits and will probably not be greater than control via therapy simulator. The decisive factor is that computerised tomography should offer sufficient possibilities of translating such control into reality by effecting the necessary dosage adjustments in accordance with given requirements. (orig.) [de

  6. Radiation exposure in CT-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Kloeckner, Roman, E-mail: Roman.Kloeckner@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Santos, Daniel Pinto dos; Schneider, Jens [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany); Kara, Levent [Department of Radiology, Inselspital Bern, Freiburgstraße 18, 3010 Bern (Switzerland); Dueber, Christoph; Pitton, Michael B. [Department of Diagnostic and Interventional Radiology, Johannes Gutenberg-University, Langenbeckstraße 1, 55131 Mainz (Germany)

    2013-12-01

    Purpose: To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. Materials and methods: We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage placements; biopsies of different organs; radiofrequency and microwave ablations (RFA/MWA) of liver, bone, and lung tumors; pain blockages, and vertebroplasties. Data were analyzed with respect to scanner settings, overall radiation doses, and individual doses of planning CT series, CT intervention, and control CT series. Results: Eighy-five percent of the total radiation dose was applied during the pre- and post-interventional CT series, leaving only 15% applied by the CT-guided intervention itself. Single slice acquisition was associated with lower doses than continuous CT-fluoroscopy (37 mGy cm vs. 153 mGy cm, p < 0.001). The third quartile of radiation doses varied considerably for different interventions. The highest doses were observed in complex interventions like RFA/MWA of the liver, followed by vertebroplasty and RFA/MWA of the lung. Conclusions: This paper suggests preliminary reference levels for various intervention types and discusses strategies for dose reduction. A multicenter registry of radiation exposure including a broader spectrum of scanners and intervention types is needed to develop definitive reference levels.

  7. Radiation dose reduction in pediatric CT

    International Nuclear Information System (INIS)

    Robinson, A.E.; Hill, E.P.; Harpen, M.D.

    1986-01-01

    The relationship between image noise and radiation dose was investigated in computed tomography (CT) images of a pediatric abdomen phantom. A protocol which provided a minimum absorbed dose consistent with acceptable image noise criteria was determined for a fourth generation CT scanner. It was found that pediatric abdominal CT scans could maintain diagnostic quality with at least a 50% reduction in dose from the manufacturers' suggested protocol. (orig.)

  8. Optimizing radiation exposure for CT localizer radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Bohrer, Evelyn; Maeder, Ulf; Fiebich, Martin [Univ. of Applied Sciences, Giessen (Germany). Inst. of Medical Physics and Radiation Protection-IMPS; Schaefer, Stefan; Krombach, Gabriele A. [Univ. Hospital Giessen (Germany). Dept. of Radiology; Noel, Peter B. [Technische Univ. Muenchen (Germany). Dept. of Diagnostic and Interventional Radiology

    2017-08-01

    The trend towards submillisievert CT scans leads to a higher dose fraction of localizer radiographs in CT examinations. The already existing technical capabilities make dose optimization of localizer radiographs worthwhile. Modern CT scanners apply automatic exposure control (AEC) based on attenuation data in such a localizer. Therefore not only this aspect but also the detectability of anatomical landmarks in the localizer for the desired CT scan range adjustment needs to be considered. The effective dose of a head, chest, and abdomen-pelvis localizer radiograph with standard factory settings and user-optimized settings was determined using Monte Carlo simulations. CT examinations of an anthropomorphic phantom were performed using multiple sets of acquisition parameters for the localizer radiograph and the AEC for the subsequent helical CT scan. Anatomical landmarks were defined to assess the image quality of the localizer. CTDI{sub vol} and effective mAs per slice of the helical CT scan were recorded to examine the impact of localizer settings on a helical CT scan. The dose of the localizer radiograph could be decreased by more than 90% while the image quality remained sufficient when selecting the lowest available settings (80 kVp, 20 mA, pa tube position). The tube position during localizer acquisition had a greater impact on the AEC than the reduction of tube voltage and tube current. Except for the use of a pa tube position, all changes of acquisition parameters for the localizer resulted in a decreased total radiation exposure. A dose reduction of CT localizer radiograph is necessary and possible. In the examined CT system there was no negative impact on the modulated helical CT scan when the lowest tube voltage and tube current were used for the localizer.

  9. What Are the Radiation Risks from CT?

    Science.gov (United States)

    ... doses. Some scientists believe that low doses of radiation do not increase the risk of developing cancer at all, but this is a minority view. More in Medical X-ray Imaging Radiography Computed Tomography (CT) Dental Cone-beam Computed Tomography Fluoroscopy Mammography Page Last ...

  10. PET/CT in Radiation Therapy Planning

    DEFF Research Database (Denmark)

    Specht, Lena; Berthelsen, Anne Kiil

    2018-01-01

    Radiation therapy (RT) is an important component of the management of lymphoma patients. Most lymphomas are metabolically active and accumulate 18F-fluorodeoxyglucose (FDG). Positron emission tomography with computer tomography (PET/CT) imaging using FDG is used routinely in staging and treatment...

  11. Radiation exposure from Chest CT: Issues and Strategies

    Science.gov (United States)

    Maher, Michael M.; Rizzo, Stefania; Kanarek, David; Shephard, Jo-Anne O.

    2004-01-01

    Concerns have been raised over alleged overuse of CT scanning and inappropriate selection of scanning methods, all of which expose patients to unnecessary radiation. Thus, it is important to identify clinical situations in which techniques with lower radiation dose such as plain radiography or no radiation such as MRI and occasionally ultrasonography can be chosen over CT scanning. This article proposes the arguments for radiation dose reduction in CT scanning of the chest and discusses recommended practices and studies that address means of reducing radiation exposure associated with CT scanning of the chest. PMID:15082885

  12. Radiation risk from CT: implications for cancer screening.

    Science.gov (United States)

    Albert, Jeffrey M

    2013-07-01

    The cancer risks associated with patient exposure to radiation from medical imaging have become a major topic of debate. The higher doses necessary for technologies such as CT and the increasing utilization of these technologies further increase medical radiation exposure to the population. Furthermore, the use of CT for population-based cancer screening continues to be explored for common malignancies such as lung cancer and colorectal cancer. Given the known carcinogenic effects of ionizing radiation, this warrants evaluation of the balance between the benefit of early cancer detection and the risk of screening-induced malignancy. This report provides a brief review of the process of radiation carcino-genesis and the literature evaluating the risk of malignancy from CT, with a focus on the risks and benefits of CT for cancer screening. The available data suggest a small but real risk of radiation-induced malignancy from CT that could become significant at the population level with widespread use of CT-based screening. However, a growing body of literature suggests that the benefits of CT screening for lung cancer in high-risk patients and CT colonography for colorectal cancer may significantly outweigh the radiation risk. Future studies evaluating the benefits of CT screening should continue to consider potential radiation risks.

  13. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  14. Strategies to reduce radiation dose in cardiac PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tung Hsin; Wu, Nien-Yun [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Wang, Shyh-Jen [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, Taipei, Taiwan (China); Department of Nuclear Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (China); Wu, Jay [Institute of Radiological science, Central Taiwan University of Science and Technology, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Huang, Tzung-Chi, E-mail: tzungchi.huang@mail.cmu.edu.tw [Department of Biomedical Imaging and Radiological Science, China Medical University, No.91 Hsueh-Shih Road, Taichung 40402, Taiwan (China)

    2011-08-21

    Background: Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications. Materials: Image quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan. Results: Radiation dose in RGH technique was 22.2{+-}4.0 mSv. It was reduced to 10.95{+-}0.82 and 4.13{+-}0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53{+-}0.5 to 0.16{+-}0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols. Conclusion: The proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  15. Radiation dosage of various CT-methods in lung diagnostics

    International Nuclear Information System (INIS)

    Heinz-Peer, G.; Weninger, F.; Nowotny, R.; Herold, C.J.

    1996-01-01

    Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to difference in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ('generation'), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing. (orig.) [de

  16. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  17. Radiation dose-reduction strategies in thoracic CT.

    Science.gov (United States)

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. CT dose profiles and MSAD calculation in a chest phantom

    International Nuclear Information System (INIS)

    Oliveira, Bruno Beraldo; Silva, Teogenes Augusto da

    2011-01-01

    For optimizing patient doses in computed tomography (CT), the Brazilian legislation has only established diagnostic reference levels (DRLs) in terms of Multiple Scan Average Dose (MSAD) in a typical adult as a quality control parameter for CT scanners. Compliance with the DRLs can be verified by measuring the Computed Tomography Air Kerma Index with a calibrated pencil ionization chamber or by obtaining the dose distribution in CT scans. An analysis of the quality of five CT scanners in Belo Horizonte was done in terms of dose profile of chest scans and MSAD determinations. Measurements were done with rod shape lithium fluoride thermoluminescent dosimeters (TLD-100) distributed in cylinders positioned in peripheral and central regions of a polymethylmethacrylate chest phantom. The peripheral regions presented higher dose values. The longitudinal dose variation can be observed and the maximum dose was recorded at the edges of the phantom at the midpoint of the longitudinal axis. The MSAD results were in according to the DRL of 25 mGy established by Brazilian legislation. The results contribute to disseminate to hospitals and radiologists the proper procedure to use the thermoluminescent dosimeters for the calculation of the MSAD from the CT dose profiles and to notice the compliance with the DRLs. (author)

  19. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  20. Radiation dose in CT are meeting the challenge

    International Nuclear Information System (INIS)

    Wang Jun

    2003-01-01

    Despite comprising only 2% of all examinations, CT contributed around 20% of the collective dose to the population from diagnostic imaging. An abdominal examination in an adult with an effective dose of 10 mSv has been estimated to increase the lifetime risk of fatal cancer by 1 in 2000. Children are 10 times more sensitive to the effects of radiation than middle aged adults. Girls are more sensitive than boys. Variations in CT practice, ease of using, urgency in multislice CT, unawaring of the 'uncoupling effect' in CT may be contributing to increasing in radiation dose. We must train and have an awareness of emerging materials and the implied changes in practice, with revision of protocols to take account of advances. The 'as low as reasonably achievable (ALARA) ' principle applies just as much to CT as it does to conventional radiography

  1. Effect of staff training on radiation dose in pediatric CT.

    Science.gov (United States)

    Hojreh, Azadeh; Weber, Michael; Homolka, Peter

    2015-08-01

    To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Spatial variation of the section sensitivity profile in helical CT

    International Nuclear Information System (INIS)

    Katsuta, Shoichi; Hanai, Kouzou; Kunii, Takeo; Kimura, Haruki; Imabayashi, Wataru; Muramatsu, Yoshihisa

    1999-01-01

    The section sensitivity profile (SSP) is adequate to express the properties of helical CT images. Although SSP measurement has been performed only at the center of the imaging field, we applied it to off-center positions using a metal bead and controlled tracking technique. The experimental results indicated that SSP curves vary in the imaging field according to the relative position of the x-ray focus. The results were in agreement with computer simulations. (author)

  3. Conditions's considerations of the CT radiation field

    International Nuclear Information System (INIS)

    Andrade, Lucio das Chagas de; Peixoto, Jose Guilherme Pereira

    2013-01-01

    In obtaining the standardization of radiation fields in diagnostic radiology were established standards and qualities to X radiation beams, which are specified in terms of the tension in the tube, first CSR, additional filters, homogeneity coefficient or second CSR. The qualities recommended in CT (RQT), are established in IEC 61267, which is the reference for the establishment of beams in diagnostic radiology. (author)

  4. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  5. Radiation protection in the diagnostic radiology. General viewpoint including CT; Strahlenschutz in der diagnostischen Radiologie. Allgemeine Sichtweise einschliesslich CT

    Energy Technology Data Exchange (ETDEWEB)

    Kroepil, Patric [Universitaetsklinikum Duesseldorf (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2017-07-01

    Radiation protection in radiology has received public attention due to reports in the media on radiation hazards due to CT. The contribution covers the issues radiation protection in radiology, including the documentation of dose information, the responsibility of radiologists for their patients, new developments with respect to dose intensive CT and the changes due to the new radiation protection law.

  6. Techniques and radiation dose in CT examinations of adult patients

    International Nuclear Information System (INIS)

    Elameen, S. E. A.

    2010-06-01

    The use of CT in medical diagnosis delivers radiation dose to patients that are higher than those from other radiological procedures. Lake of optimized protocols could be an additional source of increased dose. The aim of this study was to measure radiation doses in CT examination of the adults in three Sudanese hospitals. Details were obtained from approximately 160 CT examination carried out in 3 hospitals (3 CT scanners). Effective dose was calculated for each examination using CT dose indices. exposure related parameters and CT D1- to- effective dose conversion factors. CT air kerma index (CT D1) and dose length products (DLP) determined were below the established international reference dose levels. The mean effective doses in this study for the head, chest, and abdomen are 0.82, 3.7 and 5.4 mGy respectively. These values were observed that the effective dose per examination was lower in Sudan than in other countries. The report of a CT survey done in these centers indicates that the mean DLP values for adult patients were ranged from 272-460 mGy cm (head) 195-995 mGy cm (chest), 270-459 mGy cm (abdomen). There are a number of observed parameters that greatly need optimization, such as minimize the scan length, without missing any vital anatomical regions, modulation of exposure parameters (kV, mA, exposure time, and slice thickness) based on patient size and age. Another possible method is through use of contrast media only to optimize diagnostic yield. The last possible method is the use of radio protective materials for protection however, in order to achieve the above optimization strategies: there is great demand to educate CT personnel on the effects of scan parameter settings on radiation dose to patients and image quality required for accurate diagnosis. (Author)

  7. Estimation of radiation cancer risk in CT-KUB

    Science.gov (United States)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Bradley, D. A.; Ang, W. C.; Bahrudin, N. A.; Mhareb, M. H. A.

    2017-08-01

    The increased demand for computed tomography (CT) in radiological scanning examinations raises the question of a potential health impact from the associated radiation exposures. Focusing on CT kidney-ureter-bladder (CT-KUB) procedures, this work was aimed at determining organ equivalent dose using a commercial CT dose calculator and providing an estimate of cancer risks. The study, which included 64 patients (32 males and 32 females, mean age 55.5 years and age range 30-80 years), involved use of a calibrated CT scanner (Siemens-Somatom Emotion 16-slice). The CT exposures parameter including tube potential, pitch factor, tube current, volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded and analyzed using CT-EXPO (Version 2.3.1, Germany). Patient organ doses, including for stomach, liver, colon, bladder, red bone marrow, prostate and ovaries were calculated and converted into cancer risks using age- and sex-specific data published in the Biological Effects of Ionizing Radiation (BEIR) VII report. With a median value scan range of 36.1 cm, the CTDIvol, DLP, and effective dose were found to be 10.7 mGy, 390.3 mGy cm and 6.2 mSv, respectively. The mean cancer risks for males and females were estimated to be respectively 25 and 46 out of 100,000 procedures with effective doses between 4.2 mSv and 10.1 mSv. Given the increased cancer risks from current CT-KUB procedures compared to conventional examinations, we propose that the low dose protocols for unenhanced CT procedures be taken into consideration before establishing imaging protocols for CT-KUB.

  8. Effect of staff training on radiation dose in pediatric CT

    Energy Technology Data Exchange (ETDEWEB)

    Hojreh, Azadeh, E-mail: azadeh.hojreh@meduniwien.ac.at [Medical University of Vienna, Department of Biological Imaging and Image-guided Therapy, Division of General and Paediatric Radiology, Waehringer Guertel 18–20, A-1090 Vienna (Austria); Weber, Michael, E-mail: michael.Weber@Meduniwien.Ac.At [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of General and Paediatric Radiology, Waehringer Guertel 18–20, A-1090 Vienna (Austria); Homolka, Peter, E-mail: peter.Homolka@Meduniwien.Ac.At [Medical University of Vienna, Centre for Medical Physics and Biomedical Engineering, Waehringer Guertel 18–20, A-1090 Vienna (Austria)

    2015-08-15

    Highlights: • Pediatric patient CT doses were compared before and after staff training. • Staff training increasing dose awareness resulted in patient dose reduction. • Application of DRL reduced number of CT's with unusually high doses. • Continuous education and training are effective regarding dose optimization. - Abstract: Objective: To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. Methods: Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen–pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. Results: A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p < 0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p > 0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal–pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen–pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs – available only for CCT and thorax CT – showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). Conclusions: Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice.

  9. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    International Nuclear Information System (INIS)

    Needell, Steven D.; Borzykowski, Ross M.; Carreira, Dominic S.; Kozy, John

    2014-01-01

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  10. CT false-profile view of the hip: a reproducible method of measuring anterior acetabular coverage using volume CT data

    Energy Technology Data Exchange (ETDEWEB)

    Needell, Steven D.; Borzykowski, Ross M. [Boca Radiology Group, Boca Raton, FL (United States); Carreira, Dominic S.; Kozy, John [Broward Health Orthopedics and Sports Medicine, Fort Lauderdale, FL (United States)

    2014-11-15

    To devise a simple, reproducible method of using CT data to measure anterior acetabular coverage that results in values analogous to metrics derived from false-profile radiographs. Volume CT images were used to generate simulated false-profile radiographs and cross-sectional false-profile views by angling a multiplanar reformat 115 through the affected acetabulum relative to a line tangential to the posterior margin of the ischial tuberosities. The anterolateral margin of the acetabulum was localized on the CT false-profile view corresponding with the cranial opening of the acetabular roof. Anterior center edge angle (CEA) was measured between a vertical line passing through the center of the femoral head and a line connecting the center of the femoral head with the anterior edge of the condensed line of the acetabulum (sourcil). Anterior CEA values measured on CT false-profile views of 38 symptomatic hips were compared with values obtained on simulated and projection false-profile radiographs. The CT false-profile view produces a cross-sectional image in the same obliquity as false-profile radiographs. Anterior CEA measured on CT false-profile views were statistically similar to values obtained with false-profile radiographs. CT technologists quickly mastered the technique of generating this view. Inter-rater reliability indicated this method to be highly reproducible. The CT false-profile view is simple to generate and anterior CEA measurements derived from it are similar to those obtained using well-positioned false-profile radiographs. Utilization of CT to assess hip geometry enables precise control of pelvic inclination, eliminates projectional errors, and minimizes limitations of image quality inherent to radiography. (orig.)

  11. Evaluation of radiation doses delivered in different chest CT protocols

    International Nuclear Information System (INIS)

    Gorycki, Tomasz; Lasek, Iwona; Kamiński, Kamil; Studniarek, Michał

    2014-01-01

    There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDI VOL ) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. CTDI VOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. Mean values of CTDI VOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDI VOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80–81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose

  12. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  13. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  14. Radiation Protection in PET-CT

    International Nuclear Information System (INIS)

    2011-10-01

    The presentation is based on the following areas: radiological monitoring installations in the production of PET radiopharmaceuticals, personal dose, dosage advertising, nuclear medicine, PET, radiation protection of patients, requirements for medical practice, regulatory aspects, dose calculation, shields, quantities, center Cudim, cyclotron and synthesis of radiopharmaceuticals, biological effects of radiation protection practices.

  15. PET/CT-guided Interventions: Personnel Radiation Dose

    International Nuclear Information System (INIS)

    Ryan, E. Ronan; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-01-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0–0.13) mSv for the primary operator, 0.01 (range 0–0.05) mSv for the nurse anesthetist, and 0.02 (range 0–0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0–0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient

  16. PET/CT-guided Interventions: Personnel Radiation Dose

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States); Hsu, Meier [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics (United States); Quinn, Brian; Dauer, Lawrence T. [Memorial Sloan-Kettering Cancer Center, Department of Medical Physics (United States); Solomon, Stephen B. [Memorial Sloan-Kettering Cancer Center, Department of Radiology (United States)

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  17. Estimating radiation risk induced by CT screening for Korean population

    Science.gov (United States)

    Yang, Won Seok; Yang, Hye Jeong; Min, Byung In

    2017-02-01

    The purposes of this study are to estimate the radiation risks induced by chest/abdomen computed tomography (CT) screening for healthcare and to determine the cancer risk level of the Korean population compared to other populations. We used an ImPACT CT Patient Dosimetry Calculator to compute the organ effective dose induced by CT screening (chest, low-dose chest, abdomen/pelvis, and chest/abdomen/pelvis CT). A risk model was applied using principles based on the BEIR VII Report in order to estimate the lifetime attributable risk (LAR) using the Korean Life Table 2010. In addition, several countries including Hong Kong, the United States (U.S.), and the United Kingdom, were selected for comparison. Herein, each population exposed radiation dose of 100 mSv was classified according to country, gender and age. For each CT screening the total organ effective dose calculated by ImPACT was 6.2, 1.5, 5.2 and 11.4 mSv, respectively. In the case of Korean female LAR, it was similar to Hong Kong female but lower than those of U.S. and U.K. females, except for those in their twenties. The LAR of Korean males was the highest for all types of CT screening. However, the difference of the risk level was negligible because of the quite low value.

  18. The Effect of Therapy Oriented CT in Radiation Therapy Planning

    International Nuclear Information System (INIS)

    Kim, Sung Kyu; Shin, Sei One; Kim, Myung Se

    1987-01-01

    The success of radiation therapy depends on exact treatment of the tumor with significant high dose for maximizing local control and excluding the normal tissues for minimizing unwanted complications. To achieve these goals, correct estimation of target volume in three dimension, exact dose distribution in tumor and normal critical structures and correction of tissue inhomogeneity are required. The effect of therapy oriented CT (planning CT) were compared with conventional simulation method in necessity of planning change, set dose, and proper distribution of tumor dose. Of 365 new patients examined, planning CT was performed in 104 patients (28%). Treatment planning was changed in 47% of head and neck tumor, 79% of intrathoracic tumor and 63% of abdominal tumor. In breast cancer and musculoskeletal tumors, planning CT was recommended for selection of adequate energy and calculation of exact dose to critical structures such as kidney or spinal cord. The average difference of tumor doses between CT planning and conventional simulation was 10% in intrathoracic and intra-abdominal tumors but 20% in head and neck tumors which suggested that tumor dose may be overestimated in conventional simulation. Although some limitations and disadvantages including the cost and irradiation during CT are still criticizing, our study showed that CT planning is very helpful in radiotherapy planning

  19. Radiation dose reduction in parasinus CT by spectral shaping

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Brand, Michael; Lell, Michael M.; Uder, Michael; Wuest, Wolfgang [University Hospital Erlangen, Department of Radiology, Erlangen (Germany); Sedlmair, Martin; Allmendinger, Thomas [Siemens Healthcare GmbH, Forchheim (Germany)

    2017-02-15

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR{sub eye} {sub globe/air} did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality. (orig.)

  20. Radiation dose reduction in parasinus CT by spectral shaping

    International Nuclear Information System (INIS)

    May, Matthias S.; Brand, Michael; Lell, Michael M.; Uder, Michael; Wuest, Wolfgang; Sedlmair, Martin; Allmendinger, Thomas

    2017-01-01

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNR_e_y_e _g_l_o_b_e_/_a_i_r did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality. (orig.)

  1. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  2. Radiation exposure monitoring: a new IHE profile

    International Nuclear Information System (INIS)

    O'Donnell, Kevin

    2011-01-01

    A method is described for gathering and distributing radiation exposure data from X-ray-based imaging procedures such as CT, angiography, fluoroscopy, mammography and digital X-ray systems with integrated generators. The data are recorded in a standard format as a DICOM dose object and are managed in a similar fashion to the DICOM images produced by the procedure. The Integrating the Healthcare Enterprise (IHE) process for standardizing such methods is presented and applications of such data for activities, such as dose QA and national dose repositories, are also discussed. (orig.)

  3. Automatic CT simulation optimization for radiation therapy: A general strategy.

    Science.gov (United States)

    Li, Hua; Yu, Lifeng; Anastasio, Mark A; Chen, Hsin-Chen; Tan, Jun; Gay, Hiram; Michalski, Jeff M; Low, Daniel A; Mutic, Sasa

    2014-03-01

    In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes

  4. Automatic CT simulation optimization for radiation therapy: A general strategy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hua, E-mail: huli@radonc.wustl.edu; Chen, Hsin-Chen; Tan, Jun; Gay, Hiram; Michalski, Jeff M.; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Yu, Lifeng [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Anastasio, Mark A. [Department of Biomedical Engineering, Washington University, St. Louis, Missouri 63110 (United States); Low, Daniel A. [Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California 90095 (United States)

    2014-03-15

    Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube

  5. Radiation risk index for pediatric CT. A patient-derived metric

    International Nuclear Information System (INIS)

    Samei, Ehsan; Tian, Xiaoyu; Paul Segars, W.; Frush, Donald P.

    2017-01-01

    There is a benefit in characterizing radiation-induced cancer risk in pediatric chest and abdominopelvic CT: a singular metric that represents the whole-body radiation burden while also accounting for age, gender and organ sensitivity. To compute an index of radiation risk for pediatric chest and abdominopelvic CT. Using a protocol approved by our institutional review board, 42 pediatric patients (age: 0-16 years, weight: 2-80 kg) were modeled into virtual whole-body anatomical models. Organ doses were estimated for clinical chest and abdominopelvic CT examinations of the patients using validated Monte Carlo simulations of two major scanner models. Using age-, size- and gender-specific organ risk coefficients, the values were converted to normalized effective dose (by dose length product) (denoted as the k factor) and a normalized risk index (denoted as the q factor). An analysis was performed to determine how these factors are correlated with patient age and size for both males and females to provide a strategy to better characterize individualized risk. The k factor was found to be exponentially correlated with the average patient diameter. For both genders, the q factor also exhibited an exponential relationship with both the average patient diameter and with patient age. For both factors, the differences between the scanner models were less than 8%. The study defines a whole-body radiation risk index for chest and abdominopelvic CT imaging, that incorporates individual estimated organ dose values, organ radiation sensitivity, patient size, exposure age and patient gender. This indexing metrology enables the assessment and potential improvement of chest and abdominopelvic CT performance through surveillance of practice dose profiles across patients and may afford improved informed communication. (orig.)

  6. Radiation risk index for pediatric CT. A patient-derived metric

    Energy Technology Data Exchange (ETDEWEB)

    Samei, Ehsan [Duke University Medical Center, Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Durham, NC (United States); Duke University Medical Center, Department of Biomedical Engineering, Electrical and Computer Engineering, Durham, NC (United States); Duke University Medical Center, Medical Physics Graduate Program, Durham, NC (United States); Tian, Xiaoyu [Duke University Medical Center, Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Durham, NC (United States); Paul Segars, W. [Duke University Medical Center, Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Durham, NC (United States); Duke University Medical Center, Medical Physics Graduate Program, Durham, NC (United States); Frush, Donald P. [Duke University Medical Center, Medical Physics Graduate Program, Durham, NC (United States); Duke University Medical Center, Division of Pediatric Radiology, Department of Radiology, Durham, NC (United States)

    2017-12-15

    There is a benefit in characterizing radiation-induced cancer risk in pediatric chest and abdominopelvic CT: a singular metric that represents the whole-body radiation burden while also accounting for age, gender and organ sensitivity. To compute an index of radiation risk for pediatric chest and abdominopelvic CT. Using a protocol approved by our institutional review board, 42 pediatric patients (age: 0-16 years, weight: 2-80 kg) were modeled into virtual whole-body anatomical models. Organ doses were estimated for clinical chest and abdominopelvic CT examinations of the patients using validated Monte Carlo simulations of two major scanner models. Using age-, size- and gender-specific organ risk coefficients, the values were converted to normalized effective dose (by dose length product) (denoted as the k factor) and a normalized risk index (denoted as the q factor). An analysis was performed to determine how these factors are correlated with patient age and size for both males and females to provide a strategy to better characterize individualized risk. The k factor was found to be exponentially correlated with the average patient diameter. For both genders, the q factor also exhibited an exponential relationship with both the average patient diameter and with patient age. For both factors, the differences between the scanner models were less than 8%. The study defines a whole-body radiation risk index for chest and abdominopelvic CT imaging, that incorporates individual estimated organ dose values, organ radiation sensitivity, patient size, exposure age and patient gender. This indexing metrology enables the assessment and potential improvement of chest and abdominopelvic CT performance through surveillance of practice dose profiles across patients and may afford improved informed communication. (orig.)

  7. Abdominal spiral CT in children: which radiation exposure is required?

    Energy Technology Data Exchange (ETDEWEB)

    Wormanns, D.; Diederich, S.; Lenzen, H.; Ludwig, K.; Papke, Karsten; Hagedorn, Claudia; Heindel, Walter [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Lange, P.; Link, T.M. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie; Dept. of Radiology, Technical Univ. Muenchen (Germany)

    2001-11-01

    We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: group A with reduced radiation exposure (tube current 50 mA, CT dose index CTDI{sub FDA} {<=}0.83 mGy) and group B with standard radiation exposure (tube current {>=}100 mA, CTDI{sub FDA} {>=}1.66 mGy). Image quality was assessed using a four-part scale ('excellent', 'good', 'sufficient', 'poor') on visual image impression and visibility of 32 anatomical details. Five experienced radiologists read the CT scans independently who were blinded to the examination parameters. Differences in ranked data were evaluated with Wilcoxon's rank sum test. No difference between groups A and B was observed in visual image impression. Detail visibility was significantly lower in group A, but the differences were limited to right upper quadrant structures (portal vein, common bile duct, pancreatic head, adrenals) and to arterial branches. Significant differences in visibility rated as 'poor' were only found for the hepatic, splenic and renal arteries; all other structures showed no difference between groups A and B. A protocol with reduced radiation exposure (50 mA, CTDI{sub FDA} {<=}0.83 mGy) allowed the demonstration of most anatomic structures in abdominal spiral CT in young children. For the precise demonstration of small details (e.g. structures of the right upper quadrant), a protocol with standard radiation exposure ({>=}100 mAs) was superior. (orig.)

  8. Dental CT: examination technique, radiation load and anatomy; Dental-CT: Untersuchungstechnik, Strahlenbelastung und Anatomie

    Energy Technology Data Exchange (ETDEWEB)

    Lenglinger, F.X.; Muhr, T. [AKH Wels (Austria). Inst. fuer Radiologie; Krennmair, G. [Praxis fuer Zahn-, Mund- und Kieferheilkunde und Implantologie, Marchtrenk (Austria)

    1999-12-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [German] Die Einfuehrung im Bereich der Computertomographiesoftware (Dental-CT) ermoeglicht dem Radiologen zusaetzlich zu den ueblichen, von den Zahnaerzten durchgefuehrten Roentgenuntersuchungen eine ueberlagerungs- und verzerrungsfreie Darstellung des Ober- und Unterkiefers. In der Implantologie ist mit dieser Darstellung eine exakte Planung moeglich. Weiterhin haben sich Duennschicht-CT-Untersuchungen auch bei der Abklaerung von Zysten, Tumoren, Frakturen, tiefen Parodontitiden und retinierten Zaehnen bewaehrt. In dieser Zeit wird ein Ueberblick ueber die Anatomie, die Untersuchungstechnik des Dental-CT und die auftretende Strahlenbelastung gegeben. Basierend auf rezente Literaturangaben kann eine Reduktion der absorbierten Dosis bei gleichbleibender Bildqualitaet durch einfache Protokollmodifikationen erzielt werden. (orig.)

  9. Fast shading correction for cone beam CT in radiation therapy via sparse sampling on planning CT.

    Science.gov (United States)

    Shi, Linxi; Tsui, Tiffany; Wei, Jikun; Zhu, Lei

    2017-05-01

    The image quality of cone beam computed tomography (CBCT) is limited by severe shading artifacts, hindering its quantitative applications in radiation therapy. In this work, we propose an image-domain shading correction method using planning CT (pCT) as prior information which is highly adaptive to clinical environment. We propose to perform shading correction via sparse sampling on pCT. The method starts with a coarse mapping between the first-pass CBCT images obtained from the Varian TrueBeam system and the pCT. The scatter correction method embedded in the Varian commercial software removes some image errors but the CBCT images still contain severe shading artifacts. The difference images between the mapped pCT and the CBCT are considered as shading errors, but only sparse shading samples are selected for correction using empirical constraints to avoid carrying over false information from pCT. A Fourier-Transform-based technique, referred to as local filtration, is proposed to efficiently process the sparse data for effective shading correction. The performance of the proposed method is evaluated on one anthropomorphic pelvis phantom and 17 patients, who were scheduled for radiation therapy. (The codes of the proposed method and sample data can be downloaded from https://sites.google.com/view/linxicbct) RESULTS: The proposed shading correction substantially improves the CBCT image quality on both the phantom and the patients to a level close to that of the pCT images. On the phantom, the spatial nonuniformity (SNU) difference between CBCT and pCT is reduced from 74 to 1 HU. The root of mean square difference of SNU between CBCT and pCT is reduced from 83 to 10 HU on the pelvis patients, and from 101 to 12 HU on the thorax patients. The robustness of the proposed shading correction is fully investigated with simulated registration errors between CBCT and pCT on the phantom and mis-registration on patients. The sparse sampling scheme of our method successfully

  10. Injection profiles with radiation induced copolymers

    International Nuclear Information System (INIS)

    Knight, B.L.; Rhudy, J.S.; Gogarty, W.B.

    1976-01-01

    The injectivity profile of a heterogeneous formation and/or vertical conformance is improved by injecting an aqueous solution into the formation, the solution containing a polymer obtained as a product of radiation-induced polymerization of acrylamide and/or methacrylamide and acrylic acid, methacrylic acid, and/or alkali metal salts thereof. The polymerization is preferably carried out in a 10 to 60 percent aqueous solution with gamma radiation; the aqueous monomer solution preferably contains 25 to 99 percent acrylamide and 1 to 75 percent sodium acrylate. Immiscible, miscible, or miscible-like displacing processes can be used in conjunction with this invention. 20 claims

  11. Dental CT: examination technique, radiation load and anatomy

    International Nuclear Information System (INIS)

    Lenglinger, F.X.; Muhr, T.

    1999-01-01

    Traditionally oral surgeons and dentists have evaluated the jaws using intraoral films and panoramic radiographs. The involvement of radiologists has been limited. In the past few years dedicated CT-software-programs developed to evaluate dental implant patients have provided a new look at the jaws. The complex anatomy is described and identified on human skulls and on axial, panoramic, and cross-sectional images. With this anatomic description Dental-CT-scans are used to demonstrate the anatomy of maxilla and the mandible. An overview of the technique of Dental-CT is provided, furthermore the radiation dose of different organs is explained. Suggestions to reduce these doses by simple modifications of the recommended protocols are given. (orig.) [de

  12. Kinetic neoclassical calculations of impurity radiation profiles

    Directory of Open Access Journals (Sweden)

    D.P. Stotler

    2017-08-01

    Full Text Available Modifications of the drift-kinetic transport code XGC0 to include the transport, ionization, and recombination of individual charge states, as well as the associated radiation, are described. The code is first applied to a simulation of an NSTX H-mode discharge with carbon impurity to demonstrate the approach to coronal equilibrium. The effects of neoclassical phenomena on the radiated power profile are examined sequentially through the activation of individual physics modules in the code. Orbit squeezing and the neoclassical inward pinch result in increased radiation for temperatures above a few hundred eV and changes to the ratios of charge state emissions at a given electron temperature. Analogous simulations with a neon impurity yield qualitatively similar results.

  13. Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, Anne Grethe; Boecker Puhakka, Katriina [Department of Radiology R, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark); Hansen, Jolanta [Department of Medical Physics, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark)

    2002-11-01

    The aim of this study was to evaluate the radiation dose given by semicoronal CT of the sacroiliac joints (SIJs) in comparison with axial CT and conventional radiography. The total effective radiation doses given by serial contiguous semicoronal and axial CT, using 5-mm slices, 120 kV and 330 mAs, were determined by measurement of organ doses using an anthropomorphic Rando Alderson phantom paced with thermoluminescence dosimeters. The doses given by conventional antero-posterior (AP) and oblique projections of the SIJs were determined similarly. In a female the total effective dose by semicoronal CT was found to be more than six times lower than by axial CT and 2.5 times lower than the dose use to obtain a conventional AP radiograph, the values being 102, 678, and 255 {mu}Sv, respectively. The effective dose by semicoronal CT was only a little higher than the dose given to obtain two oblique radiographs. In a male with lead protection of the gonads the dose by semicoronal CT was four times lower than by axial CT, but higher than by conventional radiography. In conclusion, the effective dose by semicoronal CT of the SIJs is lower than by axial CT, and in females a semicoronal CT implies a lower effective radiation dose that used to obtain an AP radiograph. (orig.)

  14. Exposing exposure: automated anatomy-specific CT radiation exposure extraction for quality assurance and radiation monitoring.

    Science.gov (United States)

    Sodickson, Aaron; Warden, Graham I; Farkas, Cameron E; Ikuta, Ichiro; Prevedello, Luciano M; Andriole, Katherine P; Khorasani, Ramin

    2012-08-01

    To develop and validate an informatics toolkit that extracts anatomy-specific computed tomography (CT) radiation exposure metrics (volume CT dose index and dose-length product) from existing digital image archives through optical character recognition of CT dose report screen captures (dose screens) combined with Digital Imaging and Communications in Medicine attributes. This institutional review board-approved HIPAA-compliant study was performed in a large urban health care delivery network. Data were drawn from a random sample of CT encounters that occurred between 2000 and 2010; images from these encounters were contained within the enterprise image archive, which encompassed images obtained at an adult academic tertiary referral hospital and its affiliated sites, including a cancer center, a community hospital, and outpatient imaging centers, as well as images imported from other facilities. Software was validated by using 150 randomly selected encounters for each major CT scanner manufacturer, with outcome measures of dose screen retrieval rate (proportion of correctly located dose screens) and anatomic assignment precision (proportion of extracted exposure data with correctly assigned anatomic region, such as head, chest, or abdomen and pelvis). The 95% binomial confidence intervals (CIs) were calculated for discrete proportions, and CIs were derived from the standard error of the mean for continuous variables. After validation, the informatics toolkit was used to populate an exposure repository from a cohort of 54 549 CT encounters; of which 29 948 had available dose screens. Validation yielded a dose screen retrieval rate of 99% (597 of 605 CT encounters; 95% CI: 98%, 100%) and an anatomic assignment precision of 94% (summed DLP fraction correct 563 in 600 CT encounters; 95% CI: 92%, 96%). Patient safety applications of the resulting data repository include benchmarking between institutions, CT protocol quality control and optimization, and cumulative

  15. CT follow-up after radiation therapy for pituitary adenomas

    International Nuclear Information System (INIS)

    Rush, S.C.; Newall, J.

    1988-01-01

    Between 1973 and 1985, 105 patients received radiation therapy as all or part of their treatment for pituitary tumor at the New York University Medical Center. Of these, 48 patients underwent computed tomography (CT) at a minimum of 2 years following treatment, with detailed reports available for analysis of tumor regression. There were 28 men with a median age of 46 years (range, 18-71 years) and 20 women with a median age of 53 years (range, 28-80 years). Tumors were classified as secretory in 23 patients, nonsecretory in 21, and undetermined in four. Sixteen patients were treated with radiation therapy alone, 23 patients with surgery and radiation therapy, and the other with bromocriptine and radiation therapy, with or without surgery. With a median follow-up of 5 years (range, 2-14 years), 16 patients developed an empty sella, 25 patients had residual sellar mass, and seven patients had persistent extrasellar components or no change in their intrasellar mass. Among patients who did not have hypopituitarism at the inception of radiation therapy, five of 13 with empty sellas and 12 of 22 with residual mass subsequently required therapy. The authors conclude that residual mass is commonly found in long-term follow-up after radiation therapy, that isolated imaging studies revealing such findings after treatment in no way herald a diagnosis of recurrence, and that hypopituitarism following pituitary radiation therapy does not correlate with the ablation or persistence of tissue within the sella

  16. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    International Nuclear Information System (INIS)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat

    2011-01-01

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI 100 as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI 100 is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, σ. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI 100 calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the

  17. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

    Energy Technology Data Exchange (ETDEWEB)

    Goma, Carles; Ruiz, Agustin; Jornet, Nuria; Latorre, Artur; Pallerol, Rosa M.; Carrasco, Pablo; Eudaldo, Teresa; Ribas, Montserrat [Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Sant Antoni Maria Claret 167, 08025 Barcelona (Spain)

    2011-03-15

    Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good

  18. Transatlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    Science.gov (United States)

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-12-01

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDI vol ), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDI vol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDI vol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  19. The generation of calandria tube (CT) inner diameter profiles from fuel channel (FC) inspection data

    Energy Technology Data Exchange (ETDEWEB)

    Sedran, P.J., E-mail: paul.sedran@amec.com [AMEC NSS, Toronto, ON (Canada); Rankin, B., E-mail: brankin@nbpower.com [NB Power, Fredericton, NB (Canada); Lemire, C., E-mail: Lemire.Christian@hydro.qc.ca [Hydro-Quebec, Montreal, QC (Canada)

    2015-07-01

    Studies of CT deformation at spacer locations, key to the development of FC deformation modelling, have been limited by the availability of gauging measurements from removed CTs. In [1], it was proposed that CT dimensional profiles could be generated using FC inspection data. Since then, the concept was investigated further by assessing: (1) the normalisation of gap measurements to the diameter of the spacer coil, (2) the validity of gap measurements from inspections of Point Lepreau and Gentilly-2, and the CT dimensional profiles generated from the inspection data.It was concluded, from the work presented in this paper, that the CT-PT gap data and the CT dimensional profiles generated using the data from the two subject inspections are reasonable. (author)

  20. Person expert in radiation protection: changing profiles

    International Nuclear Information System (INIS)

    Anon.

    2015-01-01

    In all French enterprises producing or using ionizing radiations, a person is in charge of the protection of workers against radiations: the expert in radiation protection (PCR). The education and training of this profession has been recently reformed, and its status will evolve by 2018 with a transposition of a European directive. While indicating the six main missions of PCRs (risk assessment, definition of protection measures, zoning optimisation, training of exposed workers, dosimetry follow-up, periodic controls), this article comments the current professional profile of PCRs who can be technicians, engineers as well as researchers. It also outlines aspects of the reform which do not satisfy PCRs' needs. A second article reports how PCRs perceive their mission on a daily basis, which obstacles they face, how they are organised to communicate between them and not to be isolated (a map of PCR regional networks is provided with indications of the number of members and of the main actions), and how the IRSN helps them. A third article evokes the content of a new standard (NF C 15-160) which defines the requirements for X ray generating installations, and the related theoretical and practical training proposed by the IRSN

  1. Profiles of US and CT imaging features with a high probability of appendicitis

    NARCIS (Netherlands)

    van Randen, A.; Laméris, W.; van Es, H.W.; ten Hove, W.; Bouma, W.H.; van Leeuwen, M.S.; van Keulen, E.M.; van der Hulst, V.P.M.; Henneman, O.D.; Bossuyt, P.M.; Boermeester, M.A.; Stoker, J.

    2010-01-01

    To identify and evaluate profiles of US and CT features associated with acute appendicitis. Consecutive patients presenting with acute abdominal pain at the emergency department were invited to participate in this study. All patients underwent US and CT. Imaging features known to be associated with

  2. Radiation exposure distribution in patients undergoing CT brain scans

    International Nuclear Information System (INIS)

    Yang Zhanshan; Feng Dinghua; Chang Zichi; Li Shijun

    1989-12-01

    The distribution of surface exposures in patients undergoing single and multiple computerized tomographic brain scans with Hitachi CT-W500 was measured by LiF(Mg, Ti) thermoluminescent dosimetry. It was found that there was no significant difference in the sufrace exposures from different scanning slices. However, the exposure doses at different scanning angles around the head were different significantly. The reference point of the maximum surface exposure was at the temporal part of the head. the maximum surface exposure was at 1.65 x 10 -3 C·kg -1 while the average exposure was 1.55 x 10 -3 C·kg -1 . The ratio of the average dose resulting from nine scans to that from a single scan was 1.3, and the surface exposure contribution of scattered radiation was computed. At the same time the radiation doses to eyes, thyroid, chest and gonads of patiens at corresponding position were also measured and were compared with those from CT cranial scans in children and skull radiographic procedures respectively

  3. Radiation protection in newer medical imaging techniques: CT colonography

    International Nuclear Information System (INIS)

    2008-01-01

    Multislice/detector computed tomography (CT) scanning, applied to visualization of the colon in CT colonography (CTC), also known as virtual colonoscopy (VC), is a relatively new application of CT introduced in recent years. The possibility of its application in population screening techniques raises a number of questions. Effort is required to ensure that the benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and by an ever increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practice lag (inevitably) behind the industrial and clinical innovations being achieved. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice to bear on the problems involved. Under its statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for worldwide application of these standards, the IAEA has developed the Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). The BSS was issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and requires radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. The IAEA programme on radiation protection of patients encourages the reduction of patient doses without losing diagnostic benefits. To facilitate this

  4. Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)

    International Nuclear Information System (INIS)

    Hui, Peter K.T.; Goo, Hyun Woo; Du, Jing; Ip, Janice J.K.; Kanzaki, Suzu; Kim, Young Jin; Kritsaneepaiboon, Supika; Lilyasari, Oktavia; Siripornpitak, Suvipaporn

    2017-01-01

    With incremental utilization of pediatric cardiac CT in congenital heart disease, it is imperative to define its current radiation dose levels in clinical practice in order to help imagers optimize CT protocols, particularly in Asia and other developing countries where CT physicists are not readily available. To evaluate current radiation dose levels and influencing factors in cardiac CT in children with congenital heart disease in Asia by conducting a retrospective multi-center, multi-vendor study. We included 1,043 pediatric cardiac CT examinations performed in 8 centers between January 2014 and December 2014 to evaluate congenital heart disease. In five weight groups, we calculated radiation dose metrics including volume CT dose index, size-specific dose estimate, dose-length product and effective dose. Age at CT exam, gender, tube voltage, scan mode, CT indication and image reconstruction algorithm were analyzed to learn whether they influenced CT radiation dose. Volume CT dose index, size-specific dose estimate, dose-length product and effective dose of pediatric cardiac CT showed variations in the range of 4.3-23.8 mGy, 4.9-17.6 mGy, 55.8-501.3 mGy circle cm and 1.5-3.2 mSv, respectively, within five weight groups. Gender, tube voltage, scan mode and cardiac function assessment significantly influenced CT radiation dose. This multi-center, multi-vendor study demonstrated variations in radiation dose metrics of pediatric cardiac CT reflecting current practice in Asia. Gender, tube voltage, scan mode and cardiac function assessment should be considered as essential radiation dose-influencing factors in developing optimal pediatric cardiac CT protocols. (orig.)

  5. Asian consortium on radiation dose of pediatric cardiac CT (ASCI-REDCARD)

    Energy Technology Data Exchange (ETDEWEB)

    Hui, Peter K.T. [Hong Kong Baptist Hospital, Department of Radiology, Hong Kong, SAR (China); Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Du, Jing [Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Beijing (China); Ip, Janice J.K. [Queen Mary Hospital, Department of Radiology, Hong Kong, SAR (China); Kanzaki, Suzu [National Cerebral and Cardiovascular Center, Department of Radiology, Osaka (Japan); Kim, Young Jin [Yonsei University, Shinchon Severance Hospital, Department of Radiology, Seoul (Korea, Republic of); Kritsaneepaiboon, Supika [Songklanagarind Hospital, Prince of Songkla University, Department of Radiology, Hat Yai (Thailand); Lilyasari, Oktavia [University of Indonesia, National Cardiovascular Center Harapan Kita, Department of Cardiology, Jakarta (Indonesia); Siripornpitak, Suvipaporn [Ramathibodi Hospital, Mahidol University, Department of Radiology, Salaya (Thailand)

    2017-07-15

    With incremental utilization of pediatric cardiac CT in congenital heart disease, it is imperative to define its current radiation dose levels in clinical practice in order to help imagers optimize CT protocols, particularly in Asia and other developing countries where CT physicists are not readily available. To evaluate current radiation dose levels and influencing factors in cardiac CT in children with congenital heart disease in Asia by conducting a retrospective multi-center, multi-vendor study. We included 1,043 pediatric cardiac CT examinations performed in 8 centers between January 2014 and December 2014 to evaluate congenital heart disease. In five weight groups, we calculated radiation dose metrics including volume CT dose index, size-specific dose estimate, dose-length product and effective dose. Age at CT exam, gender, tube voltage, scan mode, CT indication and image reconstruction algorithm were analyzed to learn whether they influenced CT radiation dose. Volume CT dose index, size-specific dose estimate, dose-length product and effective dose of pediatric cardiac CT showed variations in the range of 4.3-23.8 mGy, 4.9-17.6 mGy, 55.8-501.3 mGy circle cm and 1.5-3.2 mSv, respectively, within five weight groups. Gender, tube voltage, scan mode and cardiac function assessment significantly influenced CT radiation dose. This multi-center, multi-vendor study demonstrated variations in radiation dose metrics of pediatric cardiac CT reflecting current practice in Asia. Gender, tube voltage, scan mode and cardiac function assessment should be considered as essential radiation dose-influencing factors in developing optimal pediatric cardiac CT protocols. (orig.)

  6. Radiation protection in newer medical imaging techniques: Cardiac CT

    International Nuclear Information System (INIS)

    2008-01-01

    Medical imaging has seen many developments as it has evolved since the mid-1890s. In the last 30-40 years, the pace of innovation has increased, starting with the introduction of computed tomography (CT) in the early 1970s. During the last decade, the rate of change has accelerated further, in terms of continuing innovation and its global application. Most patient exposure now arises from practices that barely existed two decades ago. These developments are evident in the technology on which this volume is based - multislice/detector CT scanning and its application in cardiac imaging. However, this advance is achieved at the cost of a radiation burden to the individual patient, and possibly to the community, if its screening potential is exploited. Much effort will be required to ensure that the undoubted benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and an increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practices lag (inevitably) behind the industrial and clinical innovations. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice from experienced practitioners to bear on the problems involved. The advice in this report has been developed as part of the IAEA's statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were issued by the IAEA and co-sponsored by organizations including the Food and Agriculture

  7. Radiation protection in newer medical imaging techniques: PET/CT

    International Nuclear Information System (INIS)

    2008-01-01

    A major part of patient exposure now arises from practices that barely existed two decades ago, and the technological basis for their successful dissemination only began to flourish in the last decade or so. Hybrid imaging systems, such as the combination of computed tomography (CT) and positron emission tomography (PET), are an example of a technique that has only been introduced in the last decade. PET/CT has established a valuable place for itself in medical research and diagnosis. However, it is an application that can result in high patient and staff doses. For practitioners and regulators, it is evident that innovation has been driven both by the imaging industry and by an increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practices lag (inevitably) behind the industrial and clinical innovations. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill the growing vacuum, by bringing up to date and timely advice from experienced practitioners to bear on the problems involved. The advice in this report has been developed within the IAEA's statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS) were issued by the IAEA and co-sponsored by organizations including the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and require the radiation protection of patients undergoing medical exposures through justification of the procedures involved and through

  8. PET/CT in radiation therapy planning; PET/CT in der Strahlentherapieplanung

    Energy Technology Data Exchange (ETDEWEB)

    Grosu, A.L. [Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Krause, B.J. [Klinik fuer Nuklearmedizin, Klinikum rechts der Isar, Technische Univ. Muenchen (Germany); Nestle, U. [Klinik fuer Nuklearmedizin, Universitaetsklinikum des Saarlandes, Homburg/Saar (Germany)

    2006-09-15

    Regarding treatment planning in radiotherapy PET offers advantages in terms of tumor delineation and the description of biological processes. To define the real impact of this investigation in radiation treatment planning, following experimental, clinical and cost/benefit analysis are required. FDG-PET has a significant impact on GTV and PTV delineation in lung cancer and can detect lymph node involvement and differentiation of malignant tissue from atelectasis. In high-grade gliomas and meningiomas, methionine-PET helps to define the GTV and differentiate tumor from normal tissue. In head and neck cancer, cervix cancer and prostate cancer the value of FDG-PET for radiation treatment planning is still under investigation. For example, FDG-PET can be superior to CT and MRI in the detection of lymph node metastases in head and neck, unknown primary cancer and differentiation of viable tumor tissue after treatment. Therefore, it could play an important role in GTV definition and sparing of normal tissue. For other entities like gastro-intestinal cancer, lymphomas, sarcoma etc., the data of the literature are yet insufficient. The imaging of hypoxia, cell proliferation, angiogenesis, apoptosis and gene expression leads to the identification of different areas of a biologically heterogeneous tumor mass that can be individually targeted using IMRT. In addition, a biological dose distribution can be generated, the so-called dose painting. However, systematical experimental and clinical trials are necessary to validate this hypothesis. (orig.)

  9. The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine. Pt. 1. The radiation risk from CT

    Energy Technology Data Exchange (ETDEWEB)

    Westra, Sjirk J. [Massachusetts General Hospital, Division of Pediatric Radiology, Boston, MA (United States)

    2014-10-15

    The theory of radiation carcinogenesis has been debated for decades. Most estimates of the radiation risks from CT have been based on extrapolations from the lifespan follow-up study of atomic bomb survivors and on follow-up studies after therapeutic radiation, using the linear no-threshold theory. Based on this, many population-based projections of induction of future cancers by CT have been published that should not be used to estimate the risk to an individual because of their large margin of error. This has changed recently with the publication of three large international cohort follow-up studies, which link observed cancers to CT scans received in childhood. A fourth ongoing multi-country study in Europe is expected to have enough statistical power to address the limitations of the prior studies. The United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) report released in 2013 specifically addresses variability in response of the pediatric population exposed to ionizing radiation. Most authorities now conclude that there is enough evidence to link future cancers to the radiation exposure from a single CT scan in childhood but that cancer risk estimates for individuals must be based on the specifics of exposure, age at exposure and absorbed dose to certain tissues. Generalizations are not appropriate, and the communication of the CT risk to individuals should be conducted within the framework of personalized medicine. (orig.)

  10. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  11. Radiation risk and protection of patients in clinical SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar; Nekolla, Elke A.; Nosske, Dietmar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Borowski, Markus [Klinikum Braunschweig, Institute of Radiation Diagnostics and Nuclear Medicine, Braunschweig (Germany)

    2014-05-15

    Clinical studies have demonstrated that hybrid single photon emission computed tomography (SPECT)/CT for various diagnostic issues has an added value as compared to SPECT alone. However, the combined acquisition of functional and anatomical images can substantially increase radiation exposure to patients, in particular when using a hybrid system with diagnostic CT capabilities. It is, therefore, essential to carefully balance the diagnostic needs and radiation protection requirements. To this end, the evidence on health effects induced by ionizing radiation is outlined. In addition, the essential concepts for estimating radiation doses and lifetime attributable cancer risks associated with SPECT/CT examinations are presented taking into account both the new recommendations of the International Commission on Radiological Protection (ICRP) as well as the most recent radiation risk models. Representative values of effective dose and lifetime attributable risk are reported for ten frequently used SPECT radiopharmaceuticals and five fully diagnostic partial-body CT examinations. A diagnostic CT scan acquired as part of a combined SPECT/CT examination contributes considerably to, and for some applications even dominates, the total patient exposure. For the common SPECT and CT examinations considered in this study, the lifetime attributable risk of developing a radiation-related cancer is less than 0.27 %/0.37 % for men/women older than 16 years, respectively, and decreases markedly with increasing age at exposure. Since there is no clinical indication for a SPECT/CT examination unless an emission scan has been indicated, the issue on justification comes down to the question of whether it is necessary to additionally acquire a low-dose CT for attenuation correction and anatomical localization of tracer uptake or even a fully diagnostic CT. In any case, SPECT/CT studies have to be optimized, e.g. by adapting dose reduction measures from state-of-the-art CT practice, and

  12. A new method for measuring coronary artery diameters with CT spatial profile curves

    International Nuclear Information System (INIS)

    Shimamoto, Ryoichi; Suzuki, Jun-ichi; Yamazaki, Tadashi; Tsuji, Taeko; Ohmoto, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Akahane, Masaaki; Ohtomo, Kuni

    2007-01-01

    Purpose: Coronary artery vascular edge recognition on computed tomography (CT) angiograms is influenced by window parameters. A noninvasive method for vascular edge recognition independent of window setting with use of multi-detector row CT was contrived and its feasibility and accuracy were estimated by intravascular ultrasound (IVUS). Methods: Multi-detector row CT was performed to obtain 29 CT spatial profile curves by setting a line cursor across short-axis coronary angiograms processed by multi-planar reconstruction. IVUS was also performed to determine the reference coronary diameter. IVUS diameter was fitted horizontally between two points on the upward and downward slopes of the profile curves and Hounsfield number was measured at the fitted level to test seven candidate indexes for definition of intravascular coronary diameter. The best index from the curves should show the best agreement with IVUS diameter. Results: Of the seven candidates the agreement was the best (agreement: 16 ± 11%) when the two ratios of Hounsfield number at the level of IVUS diameter over that at the peak on the profile curves were used with water and with fat as the background tissue. These edge definitions were achieved by cutting the horizontal distance by the curves at the level defined by the ratio of 0.41 for water background and 0.57 for fat background. Conclusions: Vascular edge recognition of the coronary artery with CT spatial profile curves was feasible and the contrived method could define the coronary diameter with reasonable agreement

  13. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  14. Current concepts in F18 FDG PET/CT-based Radiation Therapy planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Percy eLee

    2012-07-01

    Full Text Available Radiation therapy is an important component of cancer therapy for early stage as well as locally advanced lung cancer. The use of F18 FDG PET/CT has come to the forefront of lung cancer staging and overall treatment decision-making. FDG PET/CT parameters such as standard uptake value and metabolic tumor volume provide important prognostic and predictive information in lung cancer. Importantly, FDG PET/CT for radiation planning has added biological information in defining the gross tumor volume as well as involved nodal disease. For example, accurate target delineation between tumor and atelectasis is facilitated by utilizing PET and CT imaging. Furthermore, there has been meaningful progress in incorporating metabolic information from FDG PET/CT imaging in radiation treatment planning strategies such as radiation dose escalation based on standard uptake value thresholds as well as using respiratory gated PET and CT planning for improved target delineation of moving targets. In addition, PET/CT based follow-up after radiation therapy has provided the possibility of early detection of local as well as distant recurrences after treatment. More research is needed to incorporate other biomarkers such as proliferative and hypoxia biomarkers in PET as well as integrating metabolic information in adaptive, patient-centered, tailored radiation therapy.

  15. The cognitive profile of children treated with radiation for acute ...

    African Journals Online (AJOL)

    The cognitive profile of children treated with radiation for acute lymphoblastic leukaemia. ... to disrupt the myelination and integrity of white matter tracts in the brain. ... The current study focused on the assessment of memory and learning, two ...

  16. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    Energy Technology Data Exchange (ETDEWEB)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Patrie, James T.; Xin, Wenjun [University of Virginia, Department of Public Health Sciences, Charlottesville, VA (United States); Wintermark, Max [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Centre Hospitalier Universitaire Vaudois, Department of Radiology, Lausanne (Switzerland)

    2014-03-15

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI{sub vol}), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI{sub vol} and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  17. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    International Nuclear Information System (INIS)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah; Patrie, James T.; Xin, Wenjun; Wintermark, Max

    2014-01-01

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI vol ), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI vol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  18. Analysis of CT radiation dose based on radiation-dose-structured reports

    International Nuclear Information System (INIS)

    Wang Weipeng; Zhang Yi; Zhang Menglong; Zhang Dapeng; Song Shaojuan

    2014-01-01

    Objective: To analyse the CT radiation dose statistically using the standardized radiation-dose-structured report (RDSR) of digital imaging and communications in medicine (DICOM). Methods: Using the self-designed software, 1230 RDSR files about CT examination were obtained searching on the picture archiving and communication system (PACS). The patient dose database was established by combination of the extracted relevant information with the scanned sites. The patients were divided into adult group (over 10 years) and child groups (0-1 year, 1-5 years, 5-10 years) according to the age. The average volume CT dose index (CTDI vol ) and dose length product (DLP) of all scans were recorded respectively, and then the effective dose (E) was estimated. The DLP value at 75% quantile was calculated and compared with the diagnostic reference level (DRL). Results: In adult group, CTDI vol and DLP values were moderately and positively correlated (r = 0.41), the highest E was observed in upper abdominal enhanced scan, and the DLP value at 75% quantile was 60% higher than DRL. In child group, their CTDI vol in group of 5-10 years was greater than that in groups of 0-1 and 1-5 years (t = 2.42, 2.04, P < 0.05); the DLP value was slightly and positively correlated with the age (r = 0.16), while E was moderately and negatively correlated with the age (r = -0.48). Conclusions: It is a simple and efficient method to use RDSR to obtain the radiation doses of patients. With the popularization of the new equipment and the application of regionalized medical platform, RDSR would become the main tool for the dosimetric level surveying and individual dose recording. (authors)

  19. Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients

    International Nuclear Information System (INIS)

    Gervaise, A.; Pernin, M.; Naulet, P.; Portron, Y.; Lapierre-Combes, M.; Esperabe-Vignau, F.

    2011-01-01

    Purpose: To evaluate the knowledge of physicians prescribing CT examinations on the radiation protection of patients. Materials and methods: A questionnaire was distributed to all clinicians on medical staff who prescribe CT examinations. Several questions related to their prescription pattern and their knowledge of radiation protection. Results: Forty-four questionnaires were analyzed. While 70% of physicians claimed that they considered the risks from exposure to ionizing radiation when prescribing a CT examination, only 25% informed their patients about those risks. Knowledge of the radiation dose delivered during CT evaluation of the abdomen and pelvis was poorly understood and the risks related to small doses of radiation were grossly underestimated. Finally, only a third of clinicians had received training with regards to radiation protection. Conclusion: While most clinicians claim that they consider the risks from exposure to ionizing radiation when prescribing a CT examination, the risks are either not well known or not known at all. Increased formation of clinicians with regards to the radiation protection of patients, maybe through a dedicated clinical rotation while in medical school, could be a solution to improve the knowledge of hospital clinicians with regards to radiation protection. (authors)

  20. [Evaluation of the knowledge of physicians prescribing CT examinations on the radiation protection of patients].

    Science.gov (United States)

    Gervaise, A; Esperabe-Vignau, F; Pernin, M; Naulet, P; Portron, Y; Lapierre-Combes, M

    2011-01-01

    To evaluate the knowledge of physicians prescribing CT examinations on the radiation protection of patients. A questionnaire was distributed to all clinicians on medical staff who prescribe CT examinations. Several questions related to their prescription pattern and their knowledge of radiation protection. Forty-four questionnaires were analyzed. While 70% of physicians claimed that they considered the risks from exposure to ionizing radiation when prescribing a CT examination, only 25% informed their patients about those risks. Knowledge of the radiation dose delivered during CT evaluation of the abdomen and pelvis was poorly understood and the risks related to small doses of radiation were grossly underestimated. Finally, only a third of clinicians had received training with regards to radiation protection. While most clinicians claim that they consider the risks from exposure to ionizing radiation when prescribing a CT examination, the risks are either not well known or not known at all. Increased formation of clinicians with regards to the radiation protection of patients, maybe through a dedicated clinical rotation while in medical school, could be a solution to improve the knowledge of hospital clinicians with regards to radiation protection. Copyright © 2011 Elsevier Masson SAS and Éditions françaises de radiologie. All rights reserved.

  1. Dynamic CT for Parathyroid Adenoma Detection: How Does Radiation Dose Compare With Nuclear Medicine?

    Science.gov (United States)

    Czarnecki, Caroline A; Einsiedel, Paul F; Phal, Pramit M; Miller, Julie A; Lichtenstein, Meir; Stella, Damien L

    2018-05-01

    Dynamic CT is increasingly used for preoperative localization of parathyroid adenomas, but concerns remain about the radiation effective dose of CT compared with that of 99m Tc-sestamibi scintigraphy. The purpose of this study was to compare the radiation dose delivered by three-phase dynamic CT with that delivered by 99m Tc-sestamibi SPECT/CT performed in accordance with our current protocols and to assess the possible reduction in effective dose achieved by decreasing the scan length (i.e., z-axis) of two phases of the dynamic CT protocol. The effective dose of a 99m Tc-sestamibi nuclear medicine parathyroid study performed with and without coregistration CT was calculated and compared with the effective dose of our current three-phase dynamic CT protocol as well as a proposed protocol involving CT with reduced scan length. The median effective dose for a 99m Tc-sestamibi nuclear medicine study was 5.6 mSv. This increased to 12.4 mSv with the addition of coregistration CT, which is higher than the median effective dose of 9.3 mSv associated with the dynamic CT protocol. Reducing the scan length of two phases in the dynamic CT protocol could reduce the median effective dose to 6.1 mSv, which would be similar to that of the dose from the 99m Tc-sestamibi study alone. Dynamic CT used for the detection of parathyroid adenoma can deliver a lower radiation dose than 99m Tc-sestamibi SPECT/CT. It may be possible to reduce the dose further by decreasing the scan length of two of the phases, although whether this has an impact on accuracy of the localization needs further investigation.

  2. Profiles of US and CT imaging features with a high probability of appendicitis

    International Nuclear Information System (INIS)

    Randen, A. van; Lameris, W.; Es, H.W. van; Hove, W. ten; Bouma, W.H.; Leeuwen, M.S. van; Keulen, E.M. van; Hulst, V.P.M. van der; Henneman, O.D.; Bossuyt, P.M.; Boermeester, M.A.; Stoker, J.

    2010-01-01

    To identify and evaluate profiles of US and CT features associated with acute appendicitis. Consecutive patients presenting with acute abdominal pain at the emergency department were invited to participate in this study. All patients underwent US and CT. Imaging features known to be associated with appendicitis, and an imaging diagnosis were prospectively recorded by two independent radiologists. A final diagnosis was assigned after 6 months. Associations between appendiceal imaging features and a final diagnosis of appendicitis were evaluated with logistic regression analysis. Appendicitis was assigned to 284 of 942 evaluated patients (30%). All evaluated features were associated with appendicitis. Imaging profiles were created after multivariable logistic regression analysis. Of 147 patients with a thickened appendix, local transducer tenderness and peri-appendiceal fat infiltration on US, 139 (95%) had appendicitis. On CT, 119 patients in whom the appendix was completely visualised, thickened, with peri-appendiceal fat infiltration and appendiceal enhancement, 114 had a final diagnosis of appendicitis (96%). When at least two of these essential features were present on US or CT, sensitivity was 92% (95% CI 89-96%) and 96% (95% CI 93-98%), respectively. Most patients with appendicitis can be categorised within a few imaging profiles on US and CT. When two of the essential features are present the diagnosis of appendicitis can be made accurately. (orig.)

  3. Profiles of US and CT imaging features with a high probability of appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Randen, A. van; Lameris, W. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands); University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Es, H.W. van [St Antonius Hospital, Department of Radiology, Nieuwegein (Netherlands); Hove, W. ten; Bouma, W.H. [Gelre Hospitals, Department of Surgery, Apeldoorn (Netherlands); Leeuwen, M.S. van [University Medical Centre, Department of Radiology, Utrecht (Netherlands); Keulen, E.M. van [Tergooi Hospitals, Department of Radiology, Hilversum (Netherlands); Hulst, V.P.M. van der [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Henneman, O.D. [Bronovo Hospital, Department of Radiology, The Hague (Netherlands); Bossuyt, P.M. [University of Amsterdam, Department of Clinical Epidemiology, Biostatistics, and Bioinformatics, Academic Medical Center, Amsterdam (Netherlands); Boermeester, M.A. [University of Amsterdam, Department of Surgery, Academic Medical Center, Amsterdam (Netherlands); Stoker, J. [University of Amsterdam, Department of Radiology, Academic Medical Center, Amsterdam (Netherlands)

    2010-07-15

    To identify and evaluate profiles of US and CT features associated with acute appendicitis. Consecutive patients presenting with acute abdominal pain at the emergency department were invited to participate in this study. All patients underwent US and CT. Imaging features known to be associated with appendicitis, and an imaging diagnosis were prospectively recorded by two independent radiologists. A final diagnosis was assigned after 6 months. Associations between appendiceal imaging features and a final diagnosis of appendicitis were evaluated with logistic regression analysis. Appendicitis was assigned to 284 of 942 evaluated patients (30%). All evaluated features were associated with appendicitis. Imaging profiles were created after multivariable logistic regression analysis. Of 147 patients with a thickened appendix, local transducer tenderness and peri-appendiceal fat infiltration on US, 139 (95%) had appendicitis. On CT, 119 patients in whom the appendix was completely visualised, thickened, with peri-appendiceal fat infiltration and appendiceal enhancement, 114 had a final diagnosis of appendicitis (96%). When at least two of these essential features were present on US or CT, sensitivity was 92% (95% CI 89-96%) and 96% (95% CI 93-98%), respectively. Most patients with appendicitis can be categorised within a few imaging profiles on US and CT. When two of the essential features are present the diagnosis of appendicitis can be made accurately. (orig.)

  4. Securing safe and informative thoracic CT examinations—Progress of radiation dose reduction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kubo, Takeshi, E-mail: tkubo@kuhp.kyoto-u.ac.jp [Department of Diagnostic Imaging and Nuclear Medicine, Kyoto University Graduate School of Medicine, 54 Shogoin Kawahara-cho, Sakyo-ku, Kyoto 606-8507 (Japan); Ohno, Yoshiharu [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan); Seo, Joon Beom [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505 (Korea, Republic of); Yamashiro, Tsuneo [Department of Radiology, Graduate School of Medical Science, University of the Ryukyus, 207 Uehara, Nishinara, Okinawa 903-0215 (Japan); Kalender, Willi A. [Institute of Medical Physics, Friedrich-Alexander-University Erlangen-Nürnberg, Henkestr. 91, 91052 Erlangen (Germany); Lee, Chang Hyun [Department of Radiology, Seoul National University Hospital, 28 Yeongeon-dong, Jongno-gu, Seoul (Korea, Republic of); Lynch, David A. [Department of Radiology, National Jewish Health, 1400 Jackson St, A330 Denver, Colorado 80206 (United States); Kauczor, Hans-Ulrich [Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Translational Lung Research Center Heidelberg (TLRC), Member of the German Center for Lung Research (DZL), Im Neuenheimer Feld 400, 69120 Heidelberg (Germany); Hatabu, Hiroto, E-mail: hhatabu@partners.org [Center for Pulmonary Functional Imaging, Department of Radiology, Brigham and Women' s Hospital, 75 Francis Street, Boston, MA 02115 (United States)

    2017-01-15

    Highlights: • Various techniques have led to substantial radiation dose reduction of chest CT. • Automatic modulation of tube current has been shown to reduce radiation dose. • Iterative reconstruction makes significant radiation dose reduction possible. • Processing time is a limitation for full iterative reconstruction, currently. • Validation of diagnostic accuracy is desirable for routine use of low dose protocols. - Abstract: The increase in the radiation exposure from CT examinations prompted the investigation on the various dose-reduction techniques. Significant dose reduction has been achieved and the level of radiation exposure of thoracic CT is expected to reach the level equivalent to several chest X-ray examinations. With more scanners with advanced dose reduction capability deployed, knowledge on the radiation dose reduction methods has become essential to clinical practice as well as academic research. This article reviews the history of dose reduction techniques, ongoing changes brought by newer technologies and areas of further investigation.

  5. The profile of CT scan findings in acute head trauma in Orotta ...

    African Journals Online (AJOL)

    The use of investigation modalities are influenced by socioeconomic and cost effectiveness of the tests. Objective and methods: The purpose of the present five months observational study was to describe the profile of cranial computed tomography (CT) scan findings of 110 cases of acute head trauma in Orotta Hospital.

  6. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    International Nuclear Information System (INIS)

    Hinzpeter, Ricarda; Sprengel, Kai; Wanner, Guido A.; Mildenberger, Peter; Alkadhi, Hatem

    2017-01-01

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  7. Repeated CT scans in trauma transfers: An analysis of indications, radiation dose exposure, and costs

    Energy Technology Data Exchange (ETDEWEB)

    Hinzpeter, Ricarda, E-mail: Ricarda.Hinzpeter@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland); Sprengel, Kai, E-mail: Kai.Sprengel@usz.ch [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Wanner, Guido A., E-mail: Guido.Wanner@sbk-vs.de [Division of Trauma Surgery, Department of Surgery, University Hospital Zurich, University of Zurich, Raemistr. 100, CH-8091 Zurich (Switzerland); Department of General Surgery, Schwarzwald-Baar Klinikum, University of Freiburg, Klinikstr. 11, D-78052 Villingen-Schwenningen (Germany); Mildenberger, Peter, E-mail: peter.mildenberger@unimedizin-mainz.de [Department of Diagnostic and Interventional Radiology, University Hospital of Mainz, Langenbeckstr. 1, D-55131 Mainz (Germany); Alkadhi, Hatem, E-mail: hatem.alkadhi@usz.ch [Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Raemistr. 100, Zurich CH-8091 (Switzerland)

    2017-03-15

    Highlights: • Repetition of CT in trauma patients occurs relatively often. • Repetition of CT is mainly caused by inadequate image data transfer. • Potentially preventable CT examinations add radiation dose to patients. • Repeated CT is associated with excess costs to the health care system. - Abstract: Objectives: To identify the number of CT scans repeated in acute trauma patients receiving imaging before being referred to a trauma center, to define indications, and to assess radiation doses and costs of repeated CT. Methods: This retrospective study included all adult trauma patients transferred from other hospitals to a Level-I trauma center during 2014. Indications for repeated CT scans were categorized into: inadequate CT image data transfer, poor image quality, repetition of head CT after head injury together with completion to whole-body CT (WBCT), and follow-up of injury known from previous CT. Radiation doses from repeated CT were determined; costs were calculated using a nation-wide fee schedule. Results: Within one year, 85/298 (28.5%) trauma patients were transferred from another hospital because of severe head injury (n = 45,53%) and major body trauma (n = 23;27%) not manageable in the referring hospital, repatriation from a foreign country (n = 14;16.5%), and no ICU-capacity (n = 3;3.5%). Of these 85 patients, 74 (87%) had repeated CT in our center because of inadequate CT data transfer (n = 29;39%), repetition of head CT with completion to WBCT (n = 24;32.5%), and follow-up of known injury (n = 21;28.5%). None occurred because of poor image quality. Cumulative dose length product (DLP) and annual costs of potential preventable, repeated CT (inadequate data transfer) was 631mSv (81′304mGy*cm) and 35′233€, respectively. Conclusion: A considerable number of transferred trauma patients undergo potentially preventable, repeated CT, adding radiation dose to patients and costs to the health care system.

  8. Radiation condition in computerized tomography (CT): determination and calibration of dosemeters

    International Nuclear Information System (INIS)

    Adrade, L.C.; Peixoto, J.G.P.

    2016-01-01

    RQT is the standard for radiation conditions in computed tomography . It simulates a beam unrelieved of a CT scanner . The camera pencil ionization dosimeter is used in CT. The LNMRI become known characterization of RQT radiation conditions and the secondary standard calibration for type pencil ionisation chambers in its lab. The obtained beam has the characteristics required by IEC 61267. The results of the calibration presented combined uncertainty expanded to 95.45% from 2.22% . (author)

  9. Influence of tube voltage on CT attenuation, radiation dose, and image quality: phantom study

    International Nuclear Information System (INIS)

    Li Fengtan; Li Dong; Zhang Yunting

    2013-01-01

    Objective: To assess the influence of tube current and tube voltage on the CT attenuation, radiation dose, and image quality. Methods: A total of 113 saline solutions with decreasing dilution of contrast medium (370 mg I/ml) was produced. MDCT scan was performed with 15 series of different settings of tube current and tube voltage. CT attenuations with 15 series of different settings were all measured, and influence of tube current and tube voltage on CT attenuations was analyzed. CT dose index (CTDIvol) was recorded. The CT attenuations with different tube voltage and current were compared with one-way ANOVA and Kruskal-Wallis rank sum test. The correlation of CT attenuation with different tube voltage and the influence of tube voltage and current on radiation dose and image quality were tested by correlation analysis. Results: Tube current (250, 200, 150, 100, and 50 mA) had no significant effect on CT attenuation (F = 0.001, 0.008, 0.075, P > 0.05), while tube voltage (120, 100, and 80 kV) had significant effect (H = 17.906, 17.906, 13.527, 20.124, 23.563, P < 0.05). The correlation between CT attenuation and tube voltage was determined with equation: CT attenuatio N_1_0_0 _k_V = 1.561 × CT attenuatio N_1_2_0 _k_v + 4.0818, CT attenuatio N_8_0 _k_v = 1.2131 × CT attenuatio N_1_2_0 _k_v + 0.9283. The influence of tube voltage on radiation dose and image quality was also analyzed, and equations were also obtained: N_1_2_0 -k_v = -5.9771 Ln (D_1_2_0 kv) + 25.412, N_1_0_0 _k_v = -10.544 Ln (D_1_0_0 _k_v) + 36.262, N_8_0 _k_v = -25.326 Ln (D_8_0 _k_v) + 62.816. According to the results of relationship among CT attenuation, radiation dose, and image quality, lower tube voltage with higher tube current can reduce the radiation dose. Conclusions: Lower tube voltage can reduce the radiation dose. However, CT attenuation was influenced, and correction should be done with the equations. (authors)

  10. Longitudinal profile monitors using Coherent Smith–Purcell radiation

    International Nuclear Information System (INIS)

    Andrews, H.L.; Bakkali Taheri, F.; Barros, J.; Bartolini, R.; Cassinari, L.; Clarke, C.; Le Corre, S.; Delerue, N.; Doucas, G.; Fuster-Martinez, N.; Konoplev, I.; Labat, M.; Perry, C.; Reichold, A.; Stevenson, S.; Vieille Grosjean, M.

    2014-01-01

    Coherent Smith–Purcell radiation has the potential of providing information on the longitudinal profile of an electron bunch. The E-203 experiment at the FACET User Facility measures bunch profiles from the SLAC linac in the hundreds of femtoseconds range and the SPESO collaboration at Synchrotron SOLEIL is planning to make an accurate 2D map of the Coherent Smith–Purcell Radiation emission. - Highlights: • Coherent Smith–Purcell radiation can be used to measure longitudinal profiles in the hundred femtoseconds range. • The current setup used by the E-203 collaboration require integration over several shots and gratings. • Reducing the integration over a single shot and a single grating still yields a meaning full result. • The SPESO experiment at SOLEIL will make a systematic study of Coherent Smith–Purcell radiation

  11. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T. [Cincinnati Children' s Hospital Medical Center, Department of Radiology, Cincinnati, OH (United States); O' Brien, Maureen M. [Cincinnati Children' s Hospital Medical Center, Division of Oncology, Cancer and Blood Disease Institute, Cincinnati, OH (United States)

    2018-02-15

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  12. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma

    International Nuclear Information System (INIS)

    Qi, Zhihua; Gates, Erica L.; Trout, Andrew T.; O'Brien, Maureen M.

    2018-01-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (P<0.0001). Average dose savings with the combined approach was 24.8±17.8% (2.60±2.51 mSv [range: 0.32-4.72 mSv]) of total CT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations. (orig.)

  13. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer

    DEFF Research Database (Denmark)

    Kornerup, Josefine S.; Brodin, Nils Patrik; Christensen, Charlotte Birk

    2015-01-01

    BACKGROUND: PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. OBJECTIVE: To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans...... used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. MATERIALS AND METHODS: Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning....... Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. RESULTS: The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost...

  14. Radiation assessment to paediatric with F-18-FDG undergo whole-body PET/CT examination

    Energy Technology Data Exchange (ETDEWEB)

    Dhalisa, H., E-mail: dhalisa82@gmail.com; Rafidah, Z. [Kluster Oncology Science and Radiology, Advanced Medical Dental Institute, Universiti Sains Malaysia (USM), Bertam, Penang (Malaysia); Mohamad, A. S. [Department of Nuclear Medicine, National Cancer Institute, No 4 Jalan P7, Presint 7, Putrajaya (Malaysia)

    2016-01-22

    This study was carried out on wholebody radiation dose assessment to paediatrics patient who undergo PET/CT scanner at Institut Kanser Negara. Consist of 68 patients with varies of malignancies and epilepsy disease case covering age between 2 years to 12 years old. This is a retrospective study from 2010-2014. The use of PET/CT scanner as an advanced tool has been proven to give an extra radiation dose to the patient. It is because of the radiation exposure from the combination of both CT and PET scans rather than a single CT or PET scan. Furthermore, a study on radiation dose to paediatric patient undergoing PET/CT is rare in Malaysia. So, the aim of this study is to estimate the wholebody effective dose to paediatric patient in Malaysia. Effective dose from PET scan was calculated based on the activity of F18 FDG and dose coefficient reported in International Commission on Radiological Protection (ICRP) Publication 106. Effective dose from CT was determined using k coefficient as reported in ICRP publication 102 and Dose Length Product (DLP) value. The average effective dose from PET and CT were found to be 7.05mSv and 5.77mSv respectively. The mean wholebody effective dose received by a patient with combined PETCT examination was 12.78mSv. These results could be used as reference for dosimetry of a patient undergoing PETCT examination in Malaysia.

  15. New development of integrated CT simulation system for radiation therapy planning

    International Nuclear Information System (INIS)

    Kushima, Takeyuki; Kono, Michio

    1993-01-01

    In order to put more accurate radiotherapy into practice, a radiotherapy planning system using CT, which is named CT simulation system, has been developed and introduced at Kobe University Hospital. The CT simulation system consists of a CT scanner, an image processing work-station, and a laser marking system. The target area of radiation is determined on each CT axial image of scout view in the work-station. Three-dimensional treatment planning is feasible on the basis of the two-dimensional tumor information in CT axial images. After setting treatment parameters, the contour of the radiation field on beam's eye view and the iso-center position are calculated by computer. This system makes it possible to choose an appropriate irradiation method and an optimal dose distribution. In the present study we examined the fundamental capability of this system. The laser marking system proved to have a very high degree of accuracy. The outcome of a phantom test raised the strong possibility that this system may be applied clinically. In addition to these basic findings, this paper describes preliminary clinical observations that support the good reproducibility of the radiation field projected with the CT simulator. In conclusion, this system is of high value for radiation therapy planning. (author)

  16. Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia

    International Nuclear Information System (INIS)

    Moorin, Rachael E; Forsyth, Rene; Gibson, David J; Fox, Richard

    2013-01-01

    Technical data on local CT practice in Western Australia were collected for five major CT providers using a self-completed questionnaire. The CTDIvol DLP and effective dose for each protocol were obtained and providers were ranked according to radiation burden for each clinical scenario. The mean, median, 75th percentile and standard deviation were calculated for both effective dose and DLP for each scenario and these values were compared with published data. CT utilisation data were used to estimate the attributable radiation dose to the WA population and the potential change in population annual effective dose according to the protocol used was estimated. We found that wide variations in technique and radiation dose exist across providers for similar examinations, producing a higher radiation burden than reported internationally. As expected, the CT protocol used dramatically affects the radiation dose received, and this has a significant effect on annual population dose. This study highlights the need for recognition and understanding of both the degree of variation in radiation dose across providers and the relatively high radiation burden afforded by protocols in use in Western Australia so that necessary dialogue can be launched for practitioner consensus on appropriate diagnostic reference levels in CT scanning. (paper)

  17. Evaluation of radiation exposure with singleslice- and a multislice-spiral CT system (a phantom study)

    International Nuclear Information System (INIS)

    Giacomuzzi, S.M.; Rieger, M.; Lottersberger, C.; Peer, S.; Peer, R.; Buchberger, W.; Bale, R.; Mallouhi, A.; Jaschke, W.; Torbica, P.; Perkmann, R.

    2001-01-01

    The purpose of study was to compare patient dose applying singleslice- and multislice-spiral CT. Methods: The examinations were performed with a singleslice-spiral CT (Highspeed Advantage; GE Medical Systems; Milwaukee, USA) and with a multislice CT systems (LightSpeed QX/i GE Medical Systems; Milwaukee, USA). For the determination of the radiation exposure (absorbed dose) a selection of most executed protocols (thorax-helical, abdomen-helical, petrous bone-axial, head-axial) were simulated using an Alderson Rando Phantom. The dose was determined by means of lithiumfluorid-thermoluminescence dosimeters (TLD-GR 200). Results: For thorax and abdomen protocols higher energy dose values could be found using a multislice CT. On the average the energy dose values were increased by 2.6 on an average in relation to single slice spiral CT. The energy dose values of the multisclice CT using head protocols could be reduced by 30% in relation to single slice spiral CT due to suitable parameter selections. The energy dose applying a petrous bone protocol resulted in an average increase by a factor 1.5 using a multislice CT. Conclusion: Using the new multislice CT technique protocol strategies must be optimized regarding the patient doses. Users can operate critically in the sense of the radiation protection only if they are aware of the occurring dose amounts to the patient. (orig.) [de

  18. Patient dose simulation in X-ray CT using a radiation treatment-planning system

    International Nuclear Information System (INIS)

    Nakae, Yasuo; Oda, Masahiko; Minamoto, Takahiro

    2003-01-01

    Medical irradiation dosage has been increasing with the development of new radiological equipment and new techniques like interventional radiology. It is fair to say that patient dose has been increased as a result of the development of multi-slice CT. A number of studies on the irradiation dose of CT have been reported, and the computed tomography dose index (CTDI) is now used as a general means of determining CT dose. However, patient dose distribution in the body varies with the patient's constitution, bowel gas in the body, and conditions of exposure. In this study, patient dose was analyzed from the viewpoint of dose distribution, using a radiation treatment-planning computer. Percent depth dose (PDD) and the off-center ratio (OCR) of the CT beam are needed to calculate dose distribution by the planning computer. Therefore, X-ray CT data were measured with various apparatuses, and beam data were sent to the planning computer. Measurement and simulation doses in the elliptical phantom (Mix-Dp: water equivalent material) were collated, and the CT irradiation dose was determined for patient dose simulation. The rotational radiation treatment technique was used to obtain the patient dose distribution of CT, and patient dose was evaluated through simulation of the dose distribution. CT images of the thorax were sent to the planning computer and simulated. The result was that the patient dose distribution of the thorax was obtained for CT examination. (author)

  19. Relationship of radiation dose and spiral pitch for multi-slice CT system

    International Nuclear Information System (INIS)

    Song Shaojuan; Wang Wei; Liu Chuanya

    2006-01-01

    Objective: To study the relations of radiation dose and spiral pitch for multi-slice CT system. Methods: 16 mm dose phantom with solidose 300/400 pen-style ion chamber inserted into each of five holes in turn was scanned with different spiral pitch by LightSpeed 16-slice CT and Sensation 16-slice and 64-slice CT and radiation dose. Results: CTDI vol of axial scan and spiral scan for the three types of CT system are: (1) LightSpeed 16-slice CT: 28.9 (axial), 51.4 (pitch 0.562), 30.8 (pitch 0.938) and 16.5 ( pitch 1.75 ); (2) Sensation 16-slice CT: 41.2(axial) and 40.3(pitch 0.5) ,41.5(pitch 1) and 43.2(pitch 1.5); (3) Sensation 64- slice CT: 41.2(axial) and 40.3(pitch 0.5),41.5(pitch 1),43.2(pitch 1.5). Conclusions: For LightSpeed 16-slice CT, the measured radiation dose decreased with the increase of spiral pitch, the image quality could keep constant only if we increase mAs. While for Sensation 16-slice and 64-slice CT system, the measured radiation dose was identical for different pitch, and the image quality was identical because of the use of mAs auto control technique The mAs should be adjusted in different way according to the type of CT system when the pitch is changed in daily operation. (authors)

  20. Measurement of radiation dose to ovaries from CT of the head and trunk

    Energy Technology Data Exchange (ETDEWEB)

    Al-Habdhan, M.A.M.; Kinsara, A.R. [King Abdul Aziz Univ., Nuclear Engineering Dept., Jeddah (Saudi Arabia)

    2001-07-01

    With the rise in concern about doses received by patients over recent years, there has been a growing requirement for information on typical doses and the range of dose received during Computerized Tomography (CT). This study was performed for the assessment of radiation dose to the ovaries from various CT protocols for head and trunk imaging. Thermo luminescent dosimeters (TLD) were used for the dosimetry measurement in an anthropomorphic Rando Alderson phantom. The wanted (obligatory) and unwanted (non-useful) radiation doses delivered to the ovaries during CT examinations of head, facial bone, orbits, abdomen, chest, pelvis, neck, nasopharynx, cervical spine, lumber spine and sacroiliac joint were assessed. The results are compared with the corresponding values published in the literature. A comparison of the received dose from CT examinations and general radiography examinations by the ovaries was made. It is found that relatively high doses of unwanted radiation are delivered with computerized tomography. (author)

  1. Is energy imparted a good measure of the radiation risk associated with CT examinations

    International Nuclear Information System (INIS)

    Huda, W.

    1984-01-01

    The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the risk per unit energy imparted can significantly underestimate the radiation risk. (author)

  2. Eye lens radiation exposure and repeated head CT scans: A problem to keep in mind

    International Nuclear Information System (INIS)

    Michel, Morgane; Jacob, Sophie; Roger, Gilles; Pelosse, Béatrice; Laurier, Dominique; Le Pointe, Hubert Ducou; Bernier, Marie-Odile

    2012-01-01

    Objectives: The deterministic character of radiation-induced cataract is being called into question, raising the possibility of a risk in patients, especially children, exposed to ionizing radiation in case of repeated head CT-scans. This study aims to estimate the eye lens doses of a pediatric population exposed to repeated head CTs and to assess the feasibility of an epidemiological study. Methods: Children treated for a cholesteatoma, who had had at least one CT-scan of the middle ear before their tenth birthday, were included. Radiation exposure has been assessed from medical records and telephone interviews. Results: Out of the 39 subjects contacted, 32 accepted to participate. A total of 76 CT-scans were retrieved from medical records. At the time of the interview (mean age: 16 years), the mean number of CT per child was 3. Cumulative mean effective and eye lens doses were 1.7 mSv and 168 mGy, respectively. Conclusion: A relatively high lens radiation dose was observed in children exposed to repeated CT-scans. Due to that exposure and despite the difficulties met when trying to reach patients’ families, a large scale epidemiological study should be performed in order to assess the risk of radiation-induced cataracts associated with repeated head CT.

  3. The effect of iodine uptake on radiation dose absorbed by patient tissues in contrast enhanced CT imaging. Implications for CT dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perisinakis, Kostas; Damilakis, John [University of Crete, Department of Medical Physics, Medical School, Heraklion, Crete (Greece); University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Tzedakis, Antonis; Papadakis, Antonios E. [University Hospital of Heraklion, Department of Medical Physics, Heraklion, Crete (Greece); Spanakis, Kostas [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); Hatzidakis, Adam [University Hospital of Heraklion, Department of Radiology, Heraklion, Crete (Greece); University of Crete, Department of Radiology, Medical School, Heraklion, Crete (Greece)

    2018-01-15

    To investigate the effect of iodine uptake on tissue/organ absorbed doses from CT exposure and its implications in CT dosimetry. The contrast-induced CT number increase of several radiosensitive tissues was retrospectively determined in 120 CT examinations involving both non-enhanced and contrast-enhanced CT imaging. CT images of a phantom containing aqueous solutions of varying iodine concentration were obtained. Plots of the CT number increase against iodine concentration were produced. The clinically occurring iodine tissue uptake was quantified by attributing recorded CT number increase to a certain concentration of aqueous iodine solution. Clinically occurring iodine uptake was represented in mathematical anthropomorphic phantoms. Standard 120 kV CT exposures were simulated using Monte Carlo methods and resulting organ doses were derived for non-enhanced and iodine contrast-enhanced CT imaging. The mean iodine uptake range during contrast-enhanced CT imaging was found to be 0.02-0.46% w/w for the investigated tissues, while the maximum value recorded was 0.82% w/w. For the same CT exposure, iodinated tissues were found to receive higher radiation dose than non-iodinated tissues, with dose increase exceeding 100% for tissues with high iodine uptake. Administration of iodinated contrast medium considerably increases radiation dose to tissues from CT exposure. (orig.)

  4. Measurement of slice sensitivity profile for a 64-slice spiral CT system

    International Nuclear Information System (INIS)

    Liu Chuanya; Qin Weichang; Wang Wei; Lu Chuanyou

    2006-01-01

    Objective: To measure and evaluate slice sensitivity profile (SSP) and the full width at half-maximum(FWHM) for a 64-slice spiral CT system. Methods: Using the same CT technique and body mode as those used for clinical CT, delta phantom was scanned with Somatom Sensation 64-slice spiral CT. SSPs and FWHM were measured both with reconstruction slice width of 0.6 mm at pitch=0.50, 0.75, 1.00, 1.25, 1.50 and with reconstruction slice width of 0.6, 1.0, 1.5 mm at pitch=1 respectively. Results: For normal slice width of 0. 6 mm, the measured FWHM, i.e. effective slice width, is 0.67, 0.67, 0.66, 0.69, 0.69 mm at different pitch. All the measured FWHM deviate less than 0.1 mm from the nominal slice width. The measured SSPs are symmetrical, bell-shaped curves without far-reaching tails, and show only slight variations as a function of the spiral pitch. When reconstruction slice width increase, relative SSP become wider. Conclusions: The variation of pitch hardly has effect all on SSP, effective slice width, and z-direction spatial resolution for Sensation 64-slice spiral CT system, which is helpful to optimize CT scanning protocol. (authors)

  5. Radiation dose reduction through combining positron emission tomography/computed tomography (PET/CT) and diagnostic CT in children and young adults with lymphoma.

    Science.gov (United States)

    Qi, Zhihua; Gates, Erica L; O'Brien, Maureen M; Trout, Andrew T

    2018-02-01

    Both [F-18]2-fluoro-2-deoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and diagnostic CT are at times required for lymphoma staging. This means some body segments are exposed twice to X-rays for generation of CT data (diagnostic CT + localization CT). To describe a combined PET/diagnostic CT approach that modulates CT tube current along the z-axis, providing diagnostic CT of some body segments and localization CT of the remaining body segments, thereby reducing patient radiation dose. We retrospectively compared total patient radiation dose between combined PET/diagnostic CT and separately acquired PET/CT and diagnostic CT exams. When available, we calculated effective doses for both approaches in the same patient; otherwise, we used data from patients of similar size. To confirm image quality, we compared image noise (Hounsfield unit [HU] standard deviation) as measured in the liver on both combined and separately acquired diagnostic CT images. We used t-tests for dose comparisons and two one-sided tests for image-quality equivalence testing. Mean total effective dose for the CT component of the combined and separately acquired diagnostic CT exams were 6.20±2.69 and 8.17±2.61 mSv, respectively (PCT effective dose. Image noise was not statistically significantly different between approaches (12.2±1.8 HU vs. 11.7±1.5 HU for the combined and separately acquired diagnostic CT images, respectively). A combined PET/diagnostic CT approach as described offers dose savings at similar image quality for children and young adults with lymphoma who have indications for both PET and diagnostic CT examinations.

  6. Diagnostic efficacy for coronary in-stent patency with parameters defined on Hounsfield CT value-spatial profile curves

    International Nuclear Information System (INIS)

    Yamazaki, Tadashi; Suzuki, Jun-ichi; Shimamoto, Ryoichi; Tsuji, Taeko; Ohmoto-Sekine, Yuki; Morita, Toshihiro; Yamashita, Hiroshi; Honye, Junko; Nagai, Ryozo; Komatsu, Shuhei; Akahane, Masaaki; Ohtomo, Kuni

    2008-01-01

    Purpose: Hounsfield CT values across coronary CT angiograms constitute CT value-spatial profile curves. These CT profile curves are independent of window settings, and therefore, parameters derived from the curves can be used for objective anatomic analyses. Applicability of parameters derived from the curves to quantification of coronary in-stent patency has not yet been evaluated. Methods: Twenty-five CT value-spatial profile curves were delineated from 10 consecutive coronary stents to test correlation between the curve derived parameter (i.e., the minimum extreme value normalized by dividing by the maximum value of the curves obtained at neighboring outside of stents) and three intravascular ultrasound (IVUS) parameters. Results: Correlation coefficients between normalized minimum extreme value of CT value-spatial profile curves and three IVUS parameters (such as patent cross-sectional in-stent area, the percentage of patent cross-sectional in-stent area, and coronary artery intra-stent diameter) were 0.65 (p < 0.01), 0.44 (p < 0.05) and 0.51 (p < 0.05), respectively. Conclusions: CT parameters defined on Hounsfield CT value-spatial profile curves correlated significantly with IVUS parameters for quantitative coronary in-stent patency. A new approach with CT coronary angiography is therefore indicated for the noninvasive assessment of in-stent re-stenosis

  7. Flavor profile of radiation processed food commodities

    International Nuclear Information System (INIS)

    Chatterjee, S.; Variyar, Prasad S.; Sharma, Arun

    2006-01-01

    Full text: Flavor is one of the major quality attributes that play an important role in driving consumer choices and preferences for food. Among the several attributes that decide the flavor quality of any food, aroma and taste are the most important. While volatile constituents contribute to aroma, taste is a perception stimulated by non-volatile principles of food. Radiation processing of food has in recent years assumed increasing importance as a method for hygenization. At the doses employed for food irradiation no significant qualitative changes in the aroma constituents have been reported in most cases. An increase in perceived aroma has however been observed in several radiation processed foods. Besides volatile aroma compounds non-volatile aroma precursors are ubiquitous in plant kingdom. These compounds have been reported to exist largely as bound glycosidic conjugates and are known to undergo breakdown during processing and storage. This results in release of free aroma, thereby, modifying the flavor quality of the product. No report, however, exists on the effect of radiation processing on these bound aroma precursors. Four major class of food namely spices, oil seeds, fruits and beverages were therefore taken up for a detailed study. With respect to aroma, an enhanced breakdown of aroma precursors namely isoeugenol and 4-vinyl guaiacol glycosides and release of free aglycones was demonstrated to result in an increased aroma quality of radiation processed monsooned coffee. Breakdown of phenyl ethanol glucoside resulted in a fruitier note to pomegranate while enhanced spicy note of irradiated nutmeg arise as a result of radiolytic break down p-cymene-7-ol rutinoside precursor and release of free p-cymene-7-ol. An increased color quality of irradiated saffron was a result of the formation of free carotene aglycones namely crocetin from its glycosidic precursors while changes in perceived taste quality of radiation processed soybean could be attributed to

  8. Profiles of radiation power density in WEGA stellarator

    International Nuclear Information System (INIS)

    Zhang, D.; Otte, M.; Giannone, L.

    2005-01-01

    On the WEGA stellarator, a 12 channel bolometer camera has been used to measure the radiation power losses of the plasma, which is heated by ECR at 2.45 GHz with a maximum power of 26 kW. The typical electron temperatures achieved are around 10 eV. The bolometer is of the Au resistor type and is positioned on the mid-plane, viewing the plasma from the low-field side with a spatial resolution of about 6 cm. The viewing angle is opened to poloidally (±47 o ) and covers the whole cross-section. Angular profiles of radiation power density (emissivity) can be achieved using the measured fluxes to the channels, which are given by the integrals along the sight lines. Using Abel inversion with maximum entropy regularisation, radial profiles of emissivity could be obtained. It is found that the angular profile of emissivity depends on the magnetic configuration, the working gas (Ar, He) and the heating scenario. Peaked and hollow emissivity profiles have been obtained by using different types of heating antenna. By changing the magnetic configuration, strong edge radiation has been observed. The largest emissivity values are obtained in the upper SOL range of Ar-discharges. This edge radiation can be reduced by shifting the flux surfaces inwards or by changing their shape at the antenna. The reconstruction of the radial profile of the emissivity was carried out in the case of a peaked angular profile with minimum edge radiation. The total radiation power was estimated by linear extrapolation of the integrated radiation power in the viewing region to the torus volume. It is typically less than 30% of the ECRH input power, but depending on the ECRH input power, again the magnetic configuration, the working gas as well as the absolute field strength on the magnetic axis. Maximum radiation losses have been obtained around 0.6·B0, where B 0 =87.5 mT is the resonant field strength of the ECRH. No evidence for impurities was obtained from spectroscopic measurements, and thus the

  9. Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.

    Science.gov (United States)

    Leiva-Salinas, C; Flors, L; Gras, P; Más-Estellés, F; Lemercier, P; Patrie, J T; Wintermark, M; Martí-Bonmatí, L

    2014-01-01

    CT is the imaging modality of choice to study the paranasal sinuses; unfortunately, it involves significant radiation dose. Our aim was to assess the diagnostic validity, image quality, and radiation-dose savings of dental conebeam CT in the evaluation of patients with suspected inflammatory disorders of the paranasal sinuses. We prospectively studied 40 patients with suspected inflammatory disorders of the sinuses with dental conebeam CT and standard CT. Two radiologists analyzed the images independently, blinded to clinical information. The image quality of both techniques and the diagnostic validity of dental conebeam CT compared with the reference standard CT were assessed by using 3 different scoring systems. Image noise, signal-to-noise ratio, and contrast-to-noise ratio were calculated for both techniques. The absorbed radiation dose to the lenses and thyroid and parotid glands was measured by using a phantom and dosimeter chips. The effective radiation dose for CT was calculated. All dental conebeam CT scans were judged of diagnostic quality. Compared with CT, the conebeam CT image noise was 37.3% higher (P radiation dose to the lenses and parotid and thyroid glands with conebeam CT was 4%, 7.8%, and 7.3% of the dose delivered to the same organs by conventional CT (P Dental conebeam CT is a valid imaging procedure for the evaluation of patients with inflammatory sinonasal disorders. © 2014 by American Journal of Neuroradiology.

  10. Evaluation of the radiation doses in newborn patients submitted to CT examinations

    International Nuclear Information System (INIS)

    De Souza Santos, William; Caldas, Linda V.E.; Belinato, Walmir; Pereira Neves, Lucio; Perini, Ana Paula

    2015-01-01

    The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objective of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)

  11. Evaluation of the radiation doses in newborn patients submitted to CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    De Souza Santos, William; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear (IPENCNEN/SP), Av. Prof. Lineu Prestes, 2242, Cidade Universitaria, 05508-000 Sao Paulo, SP, (Brazil); Belinato, Walmir [Departamento de Ensino, Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia, Campus Vitoria da Conquista, Zabele, Av. Amazonas 3150, 45030-220 Vitoria da Conquista, BA, (Brazil); Pereira Neves, Lucio; Perini, Ana Paula [Instituto de Fisica, Universidade Federal de Uberlandia, Caixa Postal 593, 38400-902, Uberlandia, MG, (Brazil)

    2015-07-01

    The number of computed tomography (CT) scans available to the population is increasing, as well as the complexity of such exams. As a result, the radiation doses are increasing as well. Considering the population exposed to CT exams, pediatric patients are considerably more sensitive to radiation than adults. They have a longer life expectancy than adults, and may receive a higher radiation dose than necessary if the CT scan settings are not adjusted for their smaller body size. As a result of these considerations, the risk of developing cancer is of great concern when newborn patients are involved. The objective of this work was to study the radiation doses on radiosensitive organs of newborn patients undergoing a whole body CT examination, utilizing Monte Carlo simulations. The novelty of this work is the use of pediatric virtual anthropomorphic phantoms, developed at the Department of Nuclear Energy at the Federal University of Pernambuco (DEN/UFPE). The CT equipment utilized during the simulations was a Discovery VCT GE PET/CT system, with a tube voltage of 140 kVp. The X-ray spectrum of this CT scanner was generated by the SRS-78 software, which takes into account the X-ray beam energy used in PET/CT procedures. The absorbed organ doses were computed employing the F6 tally (MeV/g). The results were converted to dose coefficients (mGy/100 mA) for all the structures, considering all employed beams. The highest dose coefficients values were obtained for the brain and the thyroid. This work provides useful information regarding the risks involving ionizing radiation in newborn patients, employing a new and reliable technique. (authors)

  12. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography.

    Science.gov (United States)

    Tao, Shu Min; Li, Xie; Schoepf, U Joseph; Nance, John W; Jacobs, Brian E; Zhou, Chang Sheng; Gu, Hai Feng; Lu, Meng Jie; Lu, Guang Ming; Zhang, Long Jiang

    2018-04-01

    To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Focused radiation hepatitis after Bragg-peak proton therapy for hepatocellular carcinoma: CT findings

    International Nuclear Information System (INIS)

    Okumura, Toshiyuki; Itai, Yuji; Tsuji, Hiroshi

    1994-01-01

    Radiation hepatitis is clearly demonstrated by noncontrast and contrast enhanced CT following radiotherapy for liver diseases. Radiation hepatitis is dependent on dose distribution and is usually demonstrated as nonsegmental bandlike lesion after photon therapy. We report a case of focused, oval-shaped radiation hepatitis that was induced by photon therapy. The attenuation difference was localized in a high-dose area caused by Bragg-peak proton therapy. 17 refs., 2 figs

  14. Radiation dose exposure in patients affected by lymphoma undergoing repeat CT examinations: how to manage the radiation dose variability.

    Science.gov (United States)

    Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Dore, Antonio; Aringhieri, Giacomo; Caramella, Davide

    2018-03-01

    To assess the variability of radiation dose exposure in patients affected by lymphoma undergoing repeat CT (computed tomography) examinations and to evaluate the influence of different scan parameters on the overall radiation dose. A series of 34 patients (12 men and 22 women with a median age of 34.4 years) with lymphoma, after the initial staging CT underwent repeat follow-up CT examinations. For each patient and each repeat examination, age, sex, use of AEC system (Automated Exposure Control, i.e. current modulation), scan length, kV value, number of acquired scans (i.e. number of phases), abdominal size diameter and dose length product (DLP) were recorded. The radiation dose of just one venous phase was singled out from the DLP of the entire examination. All scan data were retrieved by our PACS (Picture Archiving and Communication System) by means of a dose monitoring software. Among the variables we considered, no significant difference of radiation dose was observed among patients of different ages nor concerning tube voltage. On the contrary the dose delivered to the patients varied depending on sex, scan length and usage of AEC. No significant difference was observed depending on the behaviour of technologists, while radiologists' choices had indirectly an impact on the radiation dose due to the different number of scans requested by each of them. Our results demonstrate that patients affected by lymphoma who undergo repeat whole body CT scanning may receive unnecessary overexposure. We quantified and analyzed the most relevant variables in order to provide a useful tool to manage properly CT dose variability, estimating the amount of additional radiation dose for every single significant variable. Additional scans, incorrect scan length and incorrect usage of AEC system are the most relevant cause of patient radiation exposure.

  15. CT dosimetry computer codes: Their influence on radiation dose estimates and the necessity for their revision under new ICRP radiation protection standards

    International Nuclear Information System (INIS)

    Kim, K. P.; Lee, J.; Bolch, W. E.

    2011-01-01

    Computed tomography (CT) dosimetry computer codes have been most commonly used due to their user friendliness, but with little consideration for potential uncertainty in estimated organ dose and their underlying limitations. Generally, radiation doses calculated with different CT dosimetry computer codes were comparable, although relatively large differences were observed for some specific organs or tissues. The largest difference in radiation doses calculated using different computer codes was observed for Siemens Sensation CT scanners. Radiation doses varied with patient age and sex. Younger patients and adult females receive a higher radiation dose in general than adult males for the same CT technique factors. There are a number of limitations of current CT dosimetry computer codes. These include unrealistic modelling of the human anatomy, a limited number of organs and tissues for dose calculation, inability to alter patient height and weight, and non-applicability to new CT technologies. Therefore, further studies are needed to overcome these limitations and to improve CT dosimetry. (authors)

  16. PET/CT Facility at Radiation Medicine Centre, BARC

    International Nuclear Information System (INIS)

    Baghel, Nawab Singh; Banerjee, Sharmila

    2017-01-01

    Positron Emission Tomography (PET) integrated with Computed Tomography in a single unit (PET/CT) has become an established and valued imaging modality in the clinical arena. Integrated PET/CT has been shown to be more accurate for lesion localisation and characterisation than either PET or CT alone. Image fusion brings together two image datasets with the intention of registering them as closely as possible. Generally, the two image datasets would have been produced on different types of medical imaging devices. Various problems can evolve when using two geographically remote imaging devices. To overcome this, in recent times there has been a move towards the integration of the two medical imaging devices into one physical unit. The use of one imaging unit to produce two different image datasets is known as hybrid imaging

  17. CT radiation dose and image quality optimization using a porcine model.

    Science.gov (United States)

    Zarb, Francis; McEntee, Mark F; Rainford, Louise

    2013-01-01

    To evaluate potential radiation dose savings and resultant image quality effects with regard to optimization of commonly performed computed tomography (CT) studies derived from imaging a porcine (pig) model. Imaging protocols for 4 clinical CT suites were developed based on the lowest milliamperage and kilovoltage, the highest pitch that could be set from current imaging protocol parameters, or both. This occurred before significant changes in noise, contrast, and spatial resolution were measured objectively on images produced from a quality assurance CT phantom. The current and derived phantom protocols were then applied to scan a porcine model for head, abdomen, and chest CT studies. Further optimized protocols were developed based on the same methodology as in the phantom study. The optimization achieved with respect to radiation dose and image quality was evaluated following data collection of radiation dose recordings and image quality review. Relative visual grading analysis of image quality criteria adapted from the European guidelines on radiology quality criteria for CT were used for studies completed with both the phantom-based or porcine-derived imaging protocols. In 5 out of 16 experimental combinations, the current clinical protocol was maintained. In 2 instances, the phantom protocol reduced radiation dose by 19% to 38%. In the remaining 9 instances, the optimization based on the porcine model further reduced radiation dose by 17% to 38%. The porcine model closely reflects anatomical structures in humans, allowing the grading of anatomical criteria as part of image quality review without radiation risks to human subjects. This study demonstrates that using a porcine model to evaluate CT optimization resulted in more radiation dose reduction than when imaging protocols were tested solely on quality assurance phantoms.

  18. Automatic radiation dose monitoring for CT of trauma patients with different protocols: feasibility and accuracy

    International Nuclear Information System (INIS)

    Higashigaito, K.; Becker, A.S.; Sprengel, K.; Simmen, H.-P.; Wanner, G.; Alkadhi, H.

    2016-01-01

    Aim: To demonstrate the feasibility and accuracy of automatic radiation dose monitoring software for computed tomography (CT) of trauma patients in a clinical setting over time, and to evaluate the potential of radiation dose reduction using iterative reconstruction (IR). Materials and methods: In a time period of 18 months, data from 378 consecutive thoraco-abdominal CT examinations of trauma patients were extracted using automatic radiation dose monitoring software, and patients were split into three cohorts: cohort 1, 64-section CT with filtered back projection, 200 mAs tube current–time product; cohort 2, 128-section CT with IR and identical imaging protocol; cohort 3, 128-section CT with IR, 150 mAs tube current–time product. Radiation dose parameters from the software were compared with the individual patient protocols. Image noise was measured and image quality was semi-quantitatively determined. Results: Automatic extraction of radiation dose metrics was feasible and accurate in all (100%) patients. All CT examinations were of diagnostic quality. There were no differences between cohorts 1 and 2 regarding volume CT dose index (CTDI_v_o_l; p=0.62), dose–length product (DLP), and effective dose (ED, both p=0.95), while noise was significantly lower (chest and abdomen, both −38%, p<0.017). Compared to cohort 1, CTDI_v_o_l, DLP, and ED in cohort 3 were significantly lower (all −25%, p<0.017), similar to the noise in the chest (–32%) and abdomen (–27%, both p<0.017). Compared to cohort 2, CTDI_v_o_l (–28%), DLP, and ED (both –26%) in cohort 3 was significantly lower (all, p<0.017), while noise in the chest (+9%) and abdomen (+18%) was significantly higher (all, p<0.017). Conclusion: Automatic radiation dose monitoring software is feasible and accurate, and can be implemented in a clinical setting for evaluating the effects of lowering radiation doses of CT protocols over time. - Highlights: • Automatic dose monitoring software can be

  19. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Zeniya, T.; Takeda, T. E-mail: ttakeda@md.tsukuba.ac.jp; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T

    2001-07-21

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  20. Integrated image presentation of transmission and fluorescent X-ray CT using synchrotron radiation

    Science.gov (United States)

    Zeniya, T.; Takeda, T.; Yu, Q.; Hasegawa, Y.; Hyodo, K.; Yuasa, T.; Hiranaka, Y.; Itai, Y.; Akatsuka, T.

    2001-07-01

    We have developed a computed tomography (CT) system with synchrotron radiation (SR) to detect fluorescent X-rays and transmitted X-rays simultaneously. Both SR transmission X-ray CT (SR-TXCT) and SR fluorescent X-ray CT (SR-FXCT) can describe cross-sectional images with high spatial and contrast resolutions as compared to conventional CT. TXCT gives morphological information and FXCT gives functional information of organs. So, superposed display system for SR-FXCT and SR-TXCT images has been developed for clinical diagnosis with higher reliability. Preliminary experiment with brain phantom was carried out and the superposition of both images was performed. The superposed SR-CT image gave us both functional and morphological information easily with high reliability, thus demonstrating the usefulness of this system.

  1. Radiation doses in head CT examinations in Serbia: comparison among different CT units

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Bozovic, P.; Stankovic, J.; Hadnadjev, D.; Stojanovic, S.

    2012-01-01

    A rapid increase in number of Computed Tomography (CT) examinations has been observed world wide. As haed CT is the most frequent CT examination, the purpose of this study was to collect and analyse patient doses in children and adults in different CT units for this procedure. The study included 8 CT units from three manufacturers (Siemens, Toshiba and General Electric). Data for adults and pediatric patients were collected in terms of CTDIvol and DLP values. The doses were estimated as a mean value of 10 patients on each CT unit. For pediatrics, doses were collected for four age groups (0-1year, >1-5years, >5-10years and >10-15years). Comparing different manufacturers and the same number of detector rows it was observed that, in case of 16 slices units, doses were very similar on Siemens and General Electric scanner. CTDIvol and DLP on Siemens scanner were 60 mGy and 1066 mGy·cm, respectively, while on General Electric those values were 66 mGy and 1050 mGy·cm. However, this trend was not observed in case of 64 slices units. CTDIvol and DLP values collected on Toshiba were much higher (177 mGy and 2109 mGy·cm) than in case of Siemens scanner (59 mGy and 1060 mGy·cm). Doses on 16 and 64 slices Siemens scanners were very similar, while on 4 slices were higher. Except in two units, doses were were in line with DRLs. In case of pediatrics, doses increase with patient age and again Siemens scanner showed the lowest values while the highest were observed on Toshiba. (authors)

  2. Decreasing the effective radiation dose in pediatric craniofacial CT by changing head position

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Kuang, Anna A.; Schwartz, Daniel L.; Selden, Nathan R.; Stevens, Donna M.; Bardo, Dianna M.E.

    2010-01-01

    Children are exposed to ionizing radiation during pre- and post-operative evaluation for craniofacial surgery. The primary purpose of the study was to decrease effective radiation dose while preserving the diagnostic quality of the study. In this prospective study 49 children were positioned during craniofacial CT (CFCT) imaging with their neck fully extended into an exaggerated sniff position, parallel to the CT gantry, to eliminate the majority of the cervical spine and the thyroid gland from radiation exposure. Image-quality and effective radiation dose comparisons were made retrospectively in age-matched controls (n = 49). When compared to CT scans reviewed retrospectively, the prospective examinations showed a statistically significant decrease in z-axis length by 16% (P < 0.0001) and delivered a reduced effective radiation dose by 18% (P < 0.0001). The subjective diagnostic quality of the exams performed in the prospective arm was maintained despite a slight decrease in the quality of the brain windows. There was statistically significant improvement in the quality of the bone windows and three-dimensional reconstructed images. Altering the position of the head by extending the neck during pediatric craniofacial CT imaging statistically reduces the effective radiation dose while maintaining the diagnostic quality of the images. (orig.)

  3. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander

    2015-01-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone...... microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase...

  4. In-room CT techniques for image-guided radiation therapy

    International Nuclear Information System (INIS)

    Ma, C.-M. Charlie; Paskalev, Kamen M.S.

    2006-01-01

    Accurate patient setup and target localization are essential to advanced radiation therapy treatment. Significant improvement has been made recently with the development of image-guided radiation therapy, in which image guidance facilitates short treatment course and high dose per fraction radiotherapy, aiming at improving tumor control and quality of life. Many imaging modalities are being investigated, including x-ray computed tomography (CT), ultrasound imaging, positron emission tomography, magnetic resonant imaging, magnetic resonant spectroscopic imaging, and kV/MV imaging with flat panel detectors. These developments provide unique imaging techniques and methods for patient setup and target localization. Some of them are different; some are complementary. This paper reviews the currently available kV x-ray CT systems used in the radiation treatment room, with a focus on the CT-on-rails systems, which are diagnostic CT scanners moving on rails installed in the treatment room. We will describe the system hardware including configurations, specifications, operation principles, and functionality. We will review software development for image fusion, structure recognition, deformation correction, target localization, and alignment. Issues related to the clinical implementation of in-room CT techniques in routine procedures are discussed, including acceptance testing and quality assurance. Clinical applications of the in-room CT systems for patient setup, target localization, and adaptive therapy are also reviewed for advanced radiotherapy treatments

  5. Ionization profile of beta radiation from radioactive cloud

    International Nuclear Information System (INIS)

    Vujovic, M.; Vojvodic, V.

    1978-01-01

    A method for calculation of the ionization profile induced by beta radiation from a radioactive cloud is given. The procedure can be applied for high altitudes of the could (H 75 km) as well as for lower ones, when the thickness of the cloud must be taken into account. The final result is given in the analytical form. (author)

  6. Computed temperature profile in materials exposed to gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ping, Tso Chin; Choong, Yap Siew; Seon, Chan Kam

    1987-06-01

    Computed temperature profiles are presented for the materials of lead, steel, concrete and water in curved shells, when they are exposed to gamma radiation. The results are based on the usual simplified theory of thermal conduction with an exponential heat source.

  7. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Priscila do Carmo; Oliveira, Paulo Marcio Campos de; Mamede, Marcelo; Silveira, Mariana de Castro; Aguiar, Polyanna; Real, Raphaela Vila, E-mail: pridili@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil); Silva, Teogenes Augusto da [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-01-15

    Objective: to evaluate the level of ambient radiation in a PET/CT center. Materials and methods: previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results: in none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/ year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion: in the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. (author)

  8. Ambient radiation levels in positron emission tomography/computed tomography (PET/CT) imaging center

    Science.gov (United States)

    Santana, Priscila do Carmo; de Oliveira, Paulo Marcio Campos; Mamede, Marcelo; Silveira, Mariana de Castro; Aguiar, Polyanna; Real, Raphaela Vila; da Silva, Teógenes Augusto

    2015-01-01

    Objective To evaluate the level of ambient radiation in a PET/CT center. Materials and Methods Previously selected and calibrated TLD-100H thermoluminescent dosimeters were utilized to measure room radiation levels. During 32 days, the detectors were placed in several strategically selected points inside the PET/CT center and in adjacent buildings. After the exposure period the dosimeters were collected and processed to determine the radiation level. Results In none of the points selected for measurements the values exceeded the radiation dose threshold for controlled area (5 mSv/year) or free area (0.5 mSv/year) as recommended by the Brazilian regulations. Conclusion In the present study the authors demonstrated that the whole shielding system is appropriate and, consequently, the workers are exposed to doses below the threshold established by Brazilian standards, provided the radiation protection standards are followed. PMID:25798004

  9. Ambient radiation levels in a microPET/CT research laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Sarmento, D.M.; Rodrigues, D.L.; Sanches, M.P.; Carneiro, J.C.G.G., E-mail: janetegc@ipen.br [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLD, of CaSO{sub 4}:Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring. (author)

  10. Ambient radiation levels in a microPET/CT research laboratory

    International Nuclear Information System (INIS)

    Sarmento, D.M.; Rodrigues, D.L.; Sanches, M.P.; Carneiro, J.C.G.G.

    2015-01-01

    This study focuses on initial radiological evaluation and the exposure situation related to the worker task in a micro-positron emission tomography/computed tomography laboratory (microPET/CT). Selected and calibrated thermoluminescent dosimeters, TLD, of CaSO 4 :Dy were used to measure room radiation levels. The detectors were placed in several selected points inside the microPET/CT laboratory and adjacent rooms. In addition, the occupationally exposed workers were monthly evaluated for external and internal exposures. In none of the selected points the dose values exceeded the radiation dose limit established for supervised area, as well as the values obtained in individual monitoring. (author)

  11. Use of PET/CT instead of CT-only when planning for radiation therapy does not notably increase life years lost in children being treated for cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kornerup, Josefine S.; Munck af Rosenschoeld, Per [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); The Niels Bohr Institute, Faculty of Science, University of Copenhagen, Copenhagen (Denmark); Brodin, Patrik [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); Institute for Onco-Physics, Albert Einstein College of Medicine of Yeshiva University, Bronx, NY (United States); Birk Christensen, Charlotte; Borgwardt, Lise [Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Bjoerk-Eriksson, Thomas [Sahlgrenska University Hospital, Department of Oncology, Gothenburg (Sweden); Kiil-Berthelsen, Anne [Rigshospitalet, Section of Radiotherapy, Department of Oncology, Copenhagen (Denmark); Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark)

    2015-04-01

    PET/CT may be more helpful than CT alone for radiation therapy planning, but the added risk due to higher doses of ionizing radiation is unknown. To estimate the risk of cancer induction and mortality attributable to the [F-18]2-fluoro-2-deoxyglucose (FDG) PET and CT scans used for radiation therapy planning in children with cancer, and compare to the risks attributable to the cancer treatment. Organ doses and effective doses were estimated for 40 children (2-18 years old) who had been scanned using PET/CT as part of radiation therapy planning. The risk of inducing secondary cancer was estimated using the models in BEIR VII. The prognosis of an induced cancer was taken into account and the reduction in life expectancy, in terms of life years lost, was estimated for the diagnostics and compared to the life years lost attributable to the therapy. Multivariate linear regression was performed to find predictors for a high contribution to life years lost from the radiation therapy planning diagnostics. The mean contribution from PET to the effective dose from one PET/CT scan was 24% (range: 7-64%). The average proportion of life years lost attributable to the nuclear medicine dose component from one PET/CT scan was 15% (range: 3-41%). The ratio of life years lost from the radiation therapy planning PET/CT scans and that of the cancer treatment was on average 0.02 (range: 0.01-0.09). Female gender was associated with increased life years lost from the scans (P < 0.001). Using FDG-PET/CT instead of CT only when defining the target volumes for radiation therapy of children with cancer does not notably increase the number of life years lost attributable to diagnostic examinations. (orig.)

  12. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  13. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  14. MO-FG-CAMPUS-IeP2-01: Characterization of Beam Shaping Filters and Photon Spectra From HVL Profiles in CT

    Energy Technology Data Exchange (ETDEWEB)

    Bujila, R [Karolinska University Hospital, Stockholm (Sweden); Royal Institute of Technology, Stockholm (Sweden); Kull, L [Sunderby Hospital, Lulea (Sweden); Nowik, P; Poludniowski, G [Karolinska University Hospital, Stockholm (Sweden); Andersson, J [Umea University, Umea (Sweden)

    2016-06-15

    Purpose: Advanced dosimetry in CT (e.g. the Monte Carlo method) requires an accurate characterization of the shaped filter and radiation quality used during a scan. The purpose of this work was to develop a method where half value layer (HVL) profiles along shaped filters could be made. From the HVL profiles the beam shaping properties and effective photon spectrum for a particular scan can be inferred. Methods: A measurement rig was developed to allow determinations of the HVL under a scatter-free narrow-beam geometry and constant focal spot to ionization chamber distance for different fan angles. For each fan angle the HVL is obtained by fitting the transmission of radiation through different thicknesses of an Al absorber (type 1100) using an appropriate model. The effective Al thickness of shaped filters and effective photon spectra are estimated using a model of photon emission from a Tungsten anode. This method is used to obtain the effective photon spectra and effective Al thickness of shaped filters for a CT scanner recently introduced to the market. Results: This study resulted in a set of effective photon spectra (central ray) for each kVp along with effective Al thicknesses of the different shaped filters. The effective photon spectra and effective Al thicknesses of shaped filters were used to obtain numerically approximated HVL profiles and compared to measured HVL profiles (mean absolute percentage error = 0.02). The central axis HVL found in the vendor’s technical documentation were compared to approximated HVL values (mean absolute percentage error = 0.03). Conclusion: This work has resulted in a unique method of measuring HVL profiles along shaped filters in CT. Further the effective photon spectra and the effective Al thicknesses of shaped filters that were obtained can be incorporated into Monte Carlo simulations.

  15. Measurement of multi-slice computed tomography dose profile with the Dose Magnifying Glass and the MOSkin radiation dosimeter

    International Nuclear Information System (INIS)

    Lian, C.P.L.; Wong, J.H.D.; Young, A.; Cutajar, D.; Petasecca, M.; Lerch, M.L.F.; Rosenfeld, A.B.

    2013-01-01

    This study describes the application of two in-house developed dosimeters, the Dose Magnifying Glass (DMG) and the MOSkin dosimeter at the Centre for Medical Radiation Physics, University of Wollongong, Australia, for the measurement of CT dose profiles for a clinical diagnostic 16-slice MSCT scanner. Two scanner modes were used; axial mode and helical mode, and the effect of varying beam collimation and pitch was studied. With an increase in beam collimation in axial mode and an increase of CT pitch in helical mode, cumulative point dose at scanner isocentre decreased while FWHM increased. There was generally good agreement to within 3% between the acquired dose profiles obtained by the DMG and the film except at dose profile tails, where film over-responded by up to 30% due to its intrinsic depth dose dependence at low doses. -- Highlights: ► This study shows the CT beam profiles acquired with our institution's detectors. ► The DMG is a relative dosimeter calibrated to absolute MOSkin readings. ► There was good agreement between dose profiles acquired by the DMG and the film

  16. CT manifestations of radiation-induced change in chest tissue

    International Nuclear Information System (INIS)

    Pagani, J.J.; Libshitz, H.I.

    1982-01-01

    The computed tomographic appearance of acute and chronic radiation change in the thorax is described. Acute radiation pneumonitis demonstrates patchy, confluent regions of increased pulmonary attenuation. Chronic changes include soft tissue density fibrotic changes that blend smoothly with the pleural surfaces and adjacent mediastinal structures. Also seen are bronchiectatic changes and distortion of normal intrathoracic anatomic relationships. Both the acute and chronic changes usually make linear lateral margins with adjacent aerated lung. Development of a discrete mass or focal cavitation after the radiation changes have become stable is suspect for recurrent tumor or infection

  17. Measurements of the ionising radiation level at a nuclear medicine facility performing PET/CT examinations

    International Nuclear Information System (INIS)

    Tulik, P.; Kowalska, M.; Golnik, N.; Budzynska, A.; Dziuk, M.

    2017-01-01

    This paper presents the results of radiation level measurements at workplaces in a nuclear medicine facility performing PET/ CT examinations. This study meticulously determines the staff radiation exposure in a PET/CT facility by tracking the path of patient movement. The measurements of the instantaneous radiation exposure were performed using an electronic radiometer with a proportional counter that was equipped with the option of recording the results on line. The measurements allowed for visualisation of the staff's instantaneous exposure caused by a patient walking through the department after the administration of "1"8F-FDG. An estimation of low doses associated with each working step and the exposure during a routine day in the department was possible. The measurements were completed by determining the average radiation level using highly sensitive thermoluminescent detectors. (authors)

  18. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction.

    Science.gov (United States)

    Rapalino, O; Kamalian, Shervin; Kamalian, Shahmir; Payabvash, S; Souza, L C S; Zhang, D; Mukta, J; Sahani, D V; Lev, M H; Pomerantz, S R

    2012-04-01

    To safeguard patient health, there is great interest in CT radiation-dose reduction. The purpose of this study was to evaluate the impact of an iterative-reconstruction algorithm, ASIR, on image-quality measures in reduced-dose head CT scans for adult patients. Using a 64-section scanner, we analyzed 100 reduced-dose adult head CT scans at 6 predefined levels of ASIR blended with FBP reconstruction. These scans were compared with 50 CT scans previously obtained at a higher routine dose without ASIR reconstruction. SNR and CNR were computed from Hounsfield unit measurements of normal GM and WM of brain parenchyma. A blinded qualitative analysis was performed in 10 lower-dose CT datasets compared with higher-dose ones without ASIR. Phantom data analysis was also performed. Lower-dose scans without ASIR had significantly lower mean GM and WM SNR (P = .003) and similar GM-WM CNR values compared with higher routine-dose scans. However, at ASIR levels of 20%-40%, there was no statistically significant difference in SNR, and at ASIR levels of ≥60%, the SNR values of the reduced-dose scans were significantly higher (P ASIR levels of ≥40% (P ASIR levels ≥60% (P ASIR in adult head CT scans reduces image noise and increases low-contrast resolution, while allowing lower radiation doses without affecting spatial resolution.

  19. Radiation therapy treatment planning: CT, MR imaging and three-dimensional planning

    International Nuclear Information System (INIS)

    Lichter, A.S.

    1987-01-01

    The accuracy and sophistication of radiation therapy treatment planning have increased rapidly in the last decade. Currently, CT-based treatment planning is standard throughout the country. Care must be taken when CT is used for treatment planning because of clear differences between diagnostic scans and scans intended for therapeutic management. The use of CT in radiation therapy planning is discussed and illustrated. MR imaging adds another dimension to treatment planning. The ability to use MR imaging directly in treatment planning involves an additional complex set of capabilities from a treatment planning system. The ability to unwarp the geometrically distorted MR image is a first step. Three-dimensional dose calculations are important to display the dose on sagittal and acoronal sections. The ability to integrate the MR and CT images into a unified radiographic image is critical. CT and MR images are two-dimensional representations of a three-dimensional problem. Through sophisticated computer graphics techniques, radiation therapists are now able to integrate a three-dimensional image of the patient into the treatment planning process. This allows the use of noncoplanar treatment plans and a detailed analysis of tumor and normal tissue anatomy; it is the first step toward a fully conformational treatment planning system. These concepts are illustrated and future research goals outlined

  20. Radiation exposure of lens, thyroid gland and testis in anthropomorphic phantom during CT examination and its protective measures

    International Nuclear Information System (INIS)

    Dai Suhua; Weng Zhigen; Wu Caifa

    1995-01-01

    The SMN-I anthropomorphic phantom was used to simulate patients and to estimate the radiation exposure of lens, thyroid gland and testes during CT examination according to hospital routine managements. The results show that the X-ray radiation doses received by the organs mentioned above are different in good and no protection shelter. Therefore, during CT examination it's of great significance to take a good protective shelter for organs which are near the CT scanning areas

  1. Ionization profile of beta radiation from radioactive cloud; Jonizacioni profil beta zracenja radioaktivnog oblaka

    Energy Technology Data Exchange (ETDEWEB)

    Vujovic, M [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia); Vojvodic, V [VTI Belgrade (Yugoslavia)

    1978-07-01

    A method for calculation of the ionization profile induced by beta radiation from a radioactive cloud is given. The procedure can be applied for high altitudes of the could (H 75 km) as well as for lower ones, when the thickness of the cloud must be taken into account. The final result is given in the analytical form. (author)

  2. New perspective in high tech radiotherapy planning using PET/CT images (Radiation oncologist's view on PET/CT usage)

    International Nuclear Information System (INIS)

    Hadjieva, T.; Bildirev, N.; Koleva, I.; Zahariev, Z.; Vasileva, V.; Encheva, E.; Sultanov, B.

    2010-01-01

    Biological images provided by 18F-FDG PET in combination with structural X ray picture currently offer the most accurate available information on tumour staging, curative antitumour effect for prognosis, impairment of organ function after treatment, as well as primary tumour detection in unknown primary metastatic disease. The authors as radiation oncologists critically have analyzed numerous clinical trials and two guidelines to prove PET/ CT benefit in radiotherapy practice. At present they found lack of scientific evidence to confirm that patient outcomes are superior as a result of the use of PET in RT planning. PET/CT offers a best image for tumour delineation only in some cases of lung cancer, mediastinal lymph nodes and malignant lymphomas. 11C methionin PET adds additional information on postoperative MRI image for brain tumours. Inflammation as postradiation phenomenon, as well as physiological organ movements leads to false-positive PET signal. High tech radiotherapy methods require delineation on precise images given after multidisciplinary team expertise - a practice that is possible only in clinical trials, These unsolved problems have raised many ethical challenges in medical, scientific and social aspect, if wide and routine use of FDG-PET u PET/CT is advocated. (authors)

  3. Absorbed radiation doses in women undergone to PET-CT exams for cancer diagnosis

    International Nuclear Information System (INIS)

    Santana, Priscila do Carmo; Bernardes, Felipe Dias; Mamede, Marcelo; Oliveira, Paulo Marcio Campos de; Silva, Teogenes Augusto da; Mourao FIlho, Arnaldo Prata

    2014-01-01

    The absorbed dose in several organs and the effective dose in patients submitted to PET-CT exams with the radiopharmaceutical 18 F-FDG were assessed. The ICRP-106 biokinetic model and thermoluminescent detectors in a anthropomorphic phantom were used. The use of the PET-CT image acquisition protocol, with the CT protocol for anatomical mapping, showed that 60% of effective dose was from the radiotracer administration, being the effective dose values for a female patient of (5.80 ± 1.57) mSv. In conclusion, patient doses can be reduced by using appropriate imaging acquisition in 18 F-FDG PET-CT examinations and promoting the compliance with the radiation protection principles. (author)

  4. Radiation risk to critical organ during brain CT

    International Nuclear Information System (INIS)

    Alaraki, N. M. E.

    2012-08-01

    Study was performed to evaluate dose to critical organ for patient undergoing CT brain in modern medical center a total of 61 patient were examined in this study. The data collected from Modern Medical Center for brain. The data collected from Modern Medical Center for brain. The eye lens dose was 31.31 mSv, skin 29.23 mSv, cranium 30.01 mSv, brain 34.50 mSv, mandible 4.39 mSv, thyroid 2.59 mSv. The organ dose value were comparable to the previous studies. (Author)

  5. [Investigation of radiation dose for lower tube voltage CT using automatic exposure control].

    Science.gov (United States)

    Takata, Mitsuo; Matsubara, Kousuke; Koshida, Kichirou; Tarohda, Tohru

    2015-04-01

    The purpose of our study was to investigate radiation dose for lower tube voltage CT using automatic exposure control (AEC). An acrylic body phantom was used, and volume CT dose indices (CTDIvol) for tube voltages of 80, 100, 120, and 135 kV were investigated with combination of AEC. Average absorbed dose in the abdomen for 100 and 120 kV were also measured using thermoluminescence dosimeters. In addition, we examined noise characteristics under the same absorbed doses. As a result, the exposure dose was not decreased even when the tube voltage was lowered, and the organ absorbed dose value became approximately 30% high. And the noise was increased under the radiographic condition to be an equal absorbed dose. Therefore, radiation dose increases when AEC is used for lower tube voltage CT under the same standard deviation (SD) setting with 120 kV, and the optimization of SD setting is crucial.

  6. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    Science.gov (United States)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  7. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast...... establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone....... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT...

  8. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    International Nuclear Information System (INIS)

    Osman, N D; Shamsuri, S B M; Razali, M A S M; Isa, S M; Tan, Y W

    2017-01-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDI vol and CTDI w ) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDI w ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients. (paper)

  9. Relationships between cone beam CT value and physical density in image guided radiation therapy

    International Nuclear Information System (INIS)

    Jiang Xiaoqin; Bai Sen; Zhong Renming; Tang Zhiquan; Jiang Qinfeng; Li Tao

    2007-01-01

    Objective: To evaluate the main factors affecting the relationship between physical density and CT value in cone-beam computed tomography(CBCT) for imaging guided radiation therapy(IGRT) by comparing the CT value in the image from cone-beam scanner and from fan-beam (FBCT) scanner of a reference phantom. Methods: A taking-park reference phantom with a set of tissue equivalent inserts was scanned at different energies different fields of view (FOV) for IGRT-CBCT and FBCT. The CT value of every insert was measured and compared. Results: The position of inserts in phantom, the size of phantom, the FOV of scanner and different energies had more effect on the relationships between physical density and the CT value from IGRT-CBCT than those from the normal FBCT. The higher the energy was, the less effect of the position of inserts in phantom, the size of phantom and the FOV of scanner on CT value, and the poorer density contrast was observed. Conclusion: At present, the CT value of IGRT-CBCT is not in the true HU value since the manufacturer has not corrected its number. Therefore, we are not able to use the CT value of CBCT for dose calculation in TPS. (authors)

  10. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact.

    Science.gov (United States)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander; Lauridsen, Torsten; Hauge, Ellen-Margrethe; Jørgensen, Henrik L; Jørgensen, Niklas Rye; Feidenhansl, Robert; Pinholt, Else Marie

    2017-09-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast establish SR micro-CT as the leading imaging modality for hard X-ray microtomography. Using SR micro-CT at voxel size 5 μm in an experimental goat mandible model, no statistically significant difference was found between the different treatment modalities nor between recipient and reconstructed bone. The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro-CT method, one histologic bone section is comparable to the 3D evaluation. Further, the two methods complement each other with knowledge on BIC in 2D and 3D. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  11. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  12. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    International Nuclear Information System (INIS)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques; Santangelo, Teresa; Duhamel, Alain; Deschildre, Antoine

    2017-01-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol 32 ) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP 32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP 32 , CTDI vol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP 32 , 0.78-1.25 mGy for the CTDI vol32 and 1.6-2.1 mGy for the SSDE. (orig.)

  13. CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Haggerty, Jay E.; Smith, Ethan A.; Dillman, Jonathan R.; Kunisaki, Shaun M.

    2015-01-01

    Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. A retrospective review of contrast-enhanced chest CT in infants (<1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDI vol was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose. (orig.)

  14. CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Haggerty, Jay E.; Smith, Ethan A.; Dillman, Jonathan R. [University of Michigan Health System, Section of Pediatric Radiology, Department of Radiology, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States); Kunisaki, Shaun M. [University of Michigan Health System, Section of Pediatric Surgery, Department of Surgery, C.S. Mott Children' s Hospital, Ann Arbor, MI (United States)

    2015-07-15

    Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. A retrospective review of contrast-enhanced chest CT in infants (<1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDI{sub vol} was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose. (orig.)

  15. Improving CT quality with optimized image parameters for radiation treatment planning and delivery guidance

    Directory of Open Access Journals (Sweden)

    Guang-Pei Chen

    2017-10-01

    Conclusion: CT image quality can be improved with the IQE protocols created in this study, to provide better soft tissue contrast, which would be beneficial for use in radiation therapy, e.g., for planning data acquisition or for IGRT for hypo-fractionated treatments.

  16. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  17. CT outperforms radiographs at a comparable radiation dose in the assessment for spondylolysis.

    Science.gov (United States)

    Fadell, Michael F; Gralla, Jane; Bercha, Istiaq; Stewart, Jaime R; Harned, Roger K; Ingram, James D; Miller, Angie L; Strain, John D; Weinman, Jason P

    2015-07-01

    Lumbar spondylolysis, a unilateral or bilateral fracture at pars interarticularis, is a common cause of low back pain in children. The initial imaging study in the diagnosis of lumbar spondylolysis has historically been lumbar spine radiographs; however, radiographs can be equivocal or false-negative. Definitive diagnosis can be achieved with computed tomography (CT), but its use has been limited due to the dose of ionizing radiation to the patient. By limiting the z-axis coverage to the relevant anatomy and optimizing the CT protocol, we are able to provide a definitive diagnosis of fractures of the pars interarticularis at comparable or lower radiation dose than commonly performed lumbar spine radiographs. As there is no gold standard for the diagnosis of spondylolysis besides surgery, we compared interobserver agreement and degree of confidence to determine which modality is preferable. Sixty-two patients with low back pain ages 5-18 years were assessed for the presence of spondylolyis. Forty-seven patients were evaluated by radiography and 15 patients were evaluated by limited field-of-view CT. Both radiographic and CT examinations were assessed anonymously in random order for the presence or absence of spondylolyisis by six raters. Agreement was assessed among raters using a Fleiss Kappa statistic for multiple raters. CT provided a significantly higher level of agreement among raters than radiographs (P < 0.001). The overall Kappa for rater agreement with radiographs was 0.24, 0.34 and 0.40 for 2, 3 or 4 views, respectively, and 0.88 with CT. Interobserver agreement is significantly greater using limited z-axis coverage CT when compared with radiographs. Radiologist confidence improved significantly with CT compared to radiographs regardless of the number of views.

  18. CT outperforms radiographs at a comparable radiation dose in the assessment for spondylolysis

    Energy Technology Data Exchange (ETDEWEB)

    Fadell, Michael F.; Stewart, Jaime R.; Harned, Roger K.; Ingram, James D.; Miller, Angie L.; Strain, John D.; Weinman, Jason P. [Children' s Hospital Colorado, Department of Radiology, Aurora, CO (United States); University of Colorado Hospital, Department of Radiology, Aurora, CO (United States); Gralla, Jane [University of Colorado Denver, Department of Pediatrics, Aurora, CO (United States); Bercha, Istiaq [Children' s Hospital Colorado, Department of Radiology, Aurora, CO (United States)

    2015-07-15

    Lumbar spondylolysis, a unilateral or bilateral fracture at pars interarticularis, is a common cause of low back pain in children. The initial imaging study in the diagnosis of lumbar spondylolysis has historically been lumbar spine radiographs; however, radiographs can be equivocal or false-negative. Definitive diagnosis can be achieved with computed tomography (CT), but its use has been limited due to the dose of ionizing radiation to the patient. By limiting the z-axis coverage to the relevant anatomy and optimizing the CT protocol, we are able to provide a definitive diagnosis of fractures of the pars interarticularis at comparable or lower radiation dose than commonly performed lumbar spine radiographs. As there is no gold standard for the diagnosis of spondylolysis besides surgery, we compared interobserver agreement and degree of confidence to determine which modality is preferable. Sixty-two patients with low back pain ages 5-18 years were assessed for the presence of spondylolysis. Forty-seven patients were evaluated by radiography and 15 patients were evaluated by limited field-of-view CT. Both radiographic and CT examinations were assessed anonymously in random order for the presence or absence of spondylolysis by six raters. Agreement was assessed among raters using a Fleiss Kappa statistic for multiple raters. CT provided a significantly higher level of agreement among raters than radiographs (P < 0.001). The overall Kappa for rater agreement with radiographs was 0.24, 0.34 and 0.40 for 2, 3 or 4 views, respectively, and 0.88 with CT. Interobserver agreement is significantly greater using limited z-axis coverage CT when compared with radiographs. Radiologist confidence improved significantly with CT compared to radiographs regardless of the number of views. (orig.)

  19. CT outperforms radiographs at a comparable radiation dose in the assessment for spondylolysis

    International Nuclear Information System (INIS)

    Fadell, Michael F.; Stewart, Jaime R.; Harned, Roger K.; Ingram, James D.; Miller, Angie L.; Strain, John D.; Weinman, Jason P.; Gralla, Jane; Bercha, Istiaq

    2015-01-01

    Lumbar spondylolysis, a unilateral or bilateral fracture at pars interarticularis, is a common cause of low back pain in children. The initial imaging study in the diagnosis of lumbar spondylolysis has historically been lumbar spine radiographs; however, radiographs can be equivocal or false-negative. Definitive diagnosis can be achieved with computed tomography (CT), but its use has been limited due to the dose of ionizing radiation to the patient. By limiting the z-axis coverage to the relevant anatomy and optimizing the CT protocol, we are able to provide a definitive diagnosis of fractures of the pars interarticularis at comparable or lower radiation dose than commonly performed lumbar spine radiographs. As there is no gold standard for the diagnosis of spondylolysis besides surgery, we compared interobserver agreement and degree of confidence to determine which modality is preferable. Sixty-two patients with low back pain ages 5-18 years were assessed for the presence of spondylolysis. Forty-seven patients were evaluated by radiography and 15 patients were evaluated by limited field-of-view CT. Both radiographic and CT examinations were assessed anonymously in random order for the presence or absence of spondylolysis by six raters. Agreement was assessed among raters using a Fleiss Kappa statistic for multiple raters. CT provided a significantly higher level of agreement among raters than radiographs (P < 0.001). The overall Kappa for rater agreement with radiographs was 0.24, 0.34 and 0.40 for 2, 3 or 4 views, respectively, and 0.88 with CT. Interobserver agreement is significantly greater using limited z-axis coverage CT when compared with radiographs. Radiologist confidence improved significantly with CT compared to radiographs regardless of the number of views. (orig.)

  20. CT of the chest in suspected child abuse using submillisievert radiation dose

    International Nuclear Information System (INIS)

    Sanchez, Thomas R.; Seibert, J.A.; Stein-Wexler, Rebecca; Lee, Justin S.; Coulter, Kevin P.

    2015-01-01

    The cornerstone of child abuse imaging is the skeletal survey, but initial imaging with radiographs may not demonstrate acute and non-displaced fractures, especially those involving the ribs. Given the high mortality of undiagnosed non-accidental trauma, timely diagnosis is crucial. CT is more sensitive in assessing rib fractures; however the effective radiation dose of a standard chest CT is high. We retrospectively identified four children (three boys, one girl; age range 1-4 months) admitted between January 2013 and February 2014 with high suspicion for non-accidental trauma from unexplained fractures of the long bones; these children all had CT of the chest when no rib fractures were evident on the skeletal survey. The absorbed radiation dose estimates for organs and tissue from the four-view chest radiographs and subsequent CT were determined using Monte Carlo photon transport software, and the effective dose was calculated using published tissue-weighting factors. In two children, CT showed multiple fractures of the ribs, scapula and vertebral body that were not evident on the initial skeletal survey. The average effective dose for a four-view chest radiograph across the four children was 0.29 mSv and the average effective dose for the chest CT was 0.56 mSv. Therefore the effective dose of a chest CT is on average less than twice that of a four-view chest radiograph. Our protocol thus shows that a reduced-dose chest CT may be useful in the evaluation of high specificity fractures of non-accidental trauma when the four-view chest radiographs are negative. (orig.)

  1. CT of the chest in suspected child abuse using submillisievert radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, Thomas R.; Seibert, J.A.; Stein-Wexler, Rebecca [Medical Center Children' s Hospital, Division of Pediatric Radiology, University of California-Davis, Sacramento, CA (United States); Lee, Justin S. [University of California-Davis, Department of Radiology, Sacramento, CA (United States); Coulter, Kevin P. [Medical Center Children' s Hospital, Department of Pediatrics, University of California-Davis, Sacramento, CA (United States)

    2015-07-15

    The cornerstone of child abuse imaging is the skeletal survey, but initial imaging with radiographs may not demonstrate acute and non-displaced fractures, especially those involving the ribs. Given the high mortality of undiagnosed non-accidental trauma, timely diagnosis is crucial. CT is more sensitive in assessing rib fractures; however the effective radiation dose of a standard chest CT is high. We retrospectively identified four children (three boys, one girl; age range 1-4 months) admitted between January 2013 and February 2014 with high suspicion for non-accidental trauma from unexplained fractures of the long bones; these children all had CT of the chest when no rib fractures were evident on the skeletal survey. The absorbed radiation dose estimates for organs and tissue from the four-view chest radiographs and subsequent CT were determined using Monte Carlo photon transport software, and the effective dose was calculated using published tissue-weighting factors. In two children, CT showed multiple fractures of the ribs, scapula and vertebral body that were not evident on the initial skeletal survey. The average effective dose for a four-view chest radiograph across the four children was 0.29 mSv and the average effective dose for the chest CT was 0.56 mSv. Therefore the effective dose of a chest CT is on average less than twice that of a four-view chest radiograph. Our protocol thus shows that a reduced-dose chest CT may be useful in the evaluation of high specificity fractures of non-accidental trauma when the four-view chest radiographs are negative. (orig.)

  2. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT

    International Nuclear Information System (INIS)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U.

    2012-01-01

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI vol values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 ± 2.5 vs. 11.4 ± 1.4, p < 0.001; 14.2 ± 3.7 vs. 16.1 ± 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 ± 201.1 vs. 849.8 ± 90.9, p < 0,001; 504.4 ± 134.4 vs. 471.5 ± 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 ± 35.8 vs. 155.5 ± 12.3 (p < 0.001), thorax 427.4 ± 44.5 vs. 388.3 ± 57.5 (p < 0.001), abdomen 520.3 ± 50.2 vs. 490.8 ± 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 ± 2.6 (4-row MDCT) and 24.1 ± 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  3. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  4. Field profile tailoring in a-Si:H radiation detectors

    International Nuclear Information System (INIS)

    Fujieda, I.; Cho, G.; Conti, M.; Drewery, J.; Kaplan, S.N.; Perez-Mendez, V.; Quershi, S.; Wildermuth, D.; Street, R.A.

    1990-03-01

    The capability of tailoring the field profile in reverse-biased a-Si:H diodes by doping and/or manipulating electrode shapes opens a way to many interesting device structures. Charge collection in a-Si:H radiation detectors is improved for high LET particle detection by inserting thin doped layers into the i-layer of the usual p-i-n diode. This buried p-i-n structure enables us to apply higher reverse-bias and the electric field is enhanced in the mid i-layer. Field profiles of the new structures are calculated and the improved charge collection process is discussed. Also discussed is the possibility of field profile tailoring by utilizing the fixed space charges in i-layers and/or manipulating electrode shapes of the reverse-biased p-i-n diodes. 10 refs., 7 figs

  5. Radiation dose reduction at a price: the effectiveness of a thyroid shield during head CT scanning

    International Nuclear Information System (INIS)

    Fu Qiang; Lu Tao; Zhang Ling

    2008-01-01

    Objective: To assess radiation dose to the thyroid in patients undergoing head CT scanning and to evaluate dose reduction to the thyroid by load shielding. Methods: A post-morterm was scanned by different model and study was undertaken to evaluate the dose reduction by thyroid lead shields and assess their practicality in a clinical setting. (a)No thyroid shields and (b) thyroid shield. One thermoluminescent dosimeters (TLDs)were placed over the thyroid gland center, A thyroid lead shield (Pb eq 0.5mm)was placed around the neck of post-morterm. Scan parameter, CTDIw and DLP were recorded. Results: (a) 0.207mSv; (b) 0.085mSv. A mean effective radiation dose reduction of 58% was seen in the shielded versus the unshielded. Conclusion: Thyroid exposure to scattered radiation from head CT scanning only once is associated with a low but not negligible risk of cancer, but accumulatived doses to the thyroid are serious, highlighting the need for increased awareness of patient radiation protection. Thyroid lead shielding yields significant radiation protection, which should be used routinely during head CT scan. (authors)

  6. Leukemia and brain tumors among children after radiation exposure from CT scans: design and methodological opportunities of the Dutch Pediatric CT Study

    NARCIS (Netherlands)

    Meulepas, Johanna M.; Ronckers, Cécile M.; Smets, Anne M. J. B.; Nievelstein, Rutger A. J.; Jahnen, Andreas; Lee, Choonsik; Kieft, Mariëtte; Laméris, Johan S.; van Herk, Marcel; Greuter, Marcel J. W.; Jeukens, Cécile R. L. P. N.; van Straten, Marcel; Visser, Otto; van Leeuwen, Flora E.; Hauptmann, Michael

    2014-01-01

    Computed tomography (CT) scans are indispensable in modern medicine; however, the spectacular rise in global use coupled with relatively high doses of ionizing radiation per examination have raised radiation protection concerns. Children are of particular concern because they are more sensitive to

  7. Leukemia and brain tumors among children after radiation exposure from CT scans : design and methodological opportunities of the Dutch Pediatric CT Study

    NARCIS (Netherlands)

    Meulepas, Johanna M.; Ronckers, Cecile M.; Smets, Anne M. J. B.; Nievelstein, Rutger A. J.; Jahnen, Andreas; Lee, Choonsik; Kieft, Mariette; Lameris, Johan S.; van Herk, Marcel; Greuter, Marcel J. W.; Jeukens, Cecile R. L. P. N.; van Straten, Marcel; Visser, Otto; van Leeuwen, Flora E.; Hauptmann, Michael

    Computed tomography (CT) scans are indispensable in modern medicine; however, the spectacular rise in global use coupled with relatively high doses of ionizing radiation per examination have raised radiation protection concerns. Children are of particular concern because they are more sensitive to

  8. Estimated risk of radiation-induced cancer from paediatric chest CT: two-year cohort study

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Tilo [Cantonal Hospital Baden, Department of Radiology, Baden (Switzerland); University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Colas, Lucie; Santangelo, Teresa; Faivre, Jean Baptiste; Remy, Jacques; Remy-Jardin, Martine [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Roser, Hans W.; Bremerich, Jens [University of Basel Hospital, Clinic of Radiology and Nuclear Medicine, Medical Physics, Basel (Switzerland)

    2015-03-01

    The increasing absolute number of paediatric CT scans raises concern about the safety and efficacy and the effects of consecutive diagnostic ionising radiation. To demonstrate a method to evaluate the lifetime attributable risk of cancer incidence/mortality due to a single low-dose helical chest CT in a two-year patient cohort. A two-year cohort of 522 paediatric helical chest CT scans acquired using a dedicated low-dose protocol were analysed retrospectively. Patient-specific estimations of radiation doses were modelled using three different mathematical phantoms. Per-organ attributable cancer risk was then estimated using epidemiological models. Additional comparison was provided for naturally occurring risks. Total lifetime attributable risk of cancer incidence remains low for all age and sex categories, being highest in female neonates (0.34%). Summation of all cancer sites analysed raised the relative lifetime attributable risk of organ cancer incidence up to 3.6% in female neonates and 2.1% in male neonates. Using dedicated scan protocols, total lifetime attributable risk of cancer incidence and mortality for chest CT is estimated low for paediatric chest CT, being highest for female neonates. (orig.)

  9. Evaluation of radiation dose in pediatric head CT examination: a phantom study

    Science.gov (United States)

    Norhasrina Nik Din, Nik; Zainon, Rafidah; Rahman, Ahmad Taufek Abdul

    2018-01-01

    The aim of this study was to evaluate the radiation dose in pediatric head Computed Tomography examination. It was reported that decreasing tube voltage in CT examination can reduce the dose to patients significantly. A head phantom was scanned with dual-energy CT at 80 kV and 120 kV. The tube current was set using automatic exposure control mode and manual setting. The pitch was adjusted to 1.4, 1.45 and 1.5 while the slice thickness was set at 5 mm. The dose was measured based on CT Dose Index (CTDI). Results from this study have shown that the image noise increases substantially with low tube voltage. The average dose was 2.60 mGy at CT imaging parameters of 80 kV and 10 - 30 mAs. The dose increases up to 17.19 mGy when the CT tube voltage increases to 120 kV. With the reduction of tube voltage from 120 kV to 80 kV, the radiation dose can be reduced by 12.1% to 15.1% without degradation of contrast-to-noise ratio.

  10. An investigation into CT radiation dose variations for head examinations on matched equipment

    International Nuclear Information System (INIS)

    Zarb, Francis; Foley, Shane; Toomey, Rachel; Rainford, Louise; Holm, Susanne; Evanoff, Michael G.

    2016-01-01

    This study investigated radiation dose and image quality differences for computed tomography (CT) head examinations across centres with matched CT equipment. Radiation dose records and imaging protocols currently employed across three European university teaching hospitals were collated, compared and coded as Centres A, B and C from specification matched CT equipment models. Patient scans (n = 40) obtained from Centres A and C were evaluated for image quality, based on the visualisation of Commission of European Community (CEC) image quality criteria using visual grading characteristic (VGC) analysis, where American Board of Radiology examiners (n = 11) stated their confidence in identifying anatomical criteria. Mean doses in terms of CT dose index (CTDI vol -mGy) and dose length product (DLP-mGy cm) were as follows: Centre A-33.12 mGy and 461.45 mGy cm; Centre B -101 mGy (base)/32 mGy (cerebrum) and 762 mGy cm and Centre C-71.98 mGy and 1047.26 mGy cm, showing a significant difference (p ≤ 0.05) in DLP across centres. VGC analysis indicated better visualisation of CEC criteria on Centre C images (VGC AUC 0.225). All three imaging protocols are routinely used clinically, and image quality is acceptable in each centre. Clinical centres with identical model CT scanners have variously customised their protocols achieving a range of dose savings and still resulting in clinically acceptable image quality. (authors)

  11. Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko; Lampinen, Anniina [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); University of Helsinki, Department of Physics, Helsinki (Finland); Palmu, Kirsi [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); School of Science, Aalto University, Department of Biomedical Engineering and Computational Science, Helsinki (Finland); Reijonen, Vappu; Kortesniemi, Mika [University of Helsinki and Helsinki University Hospital, HUS Medical Imaging Center, Radiology, POB 340, Helsinki (Finland); Leikola, Junnu [University of Helsinki and Helsinki University Hospital, Department of Plastic Surgery, Helsinki (Finland); Kivisaari, Riku [University of Helsinki and Helsinki University Hospital, Department of Neurosurgery, Helsinki (Finland)

    2015-09-15

    Medical professionals need to exercise particular caution when developing CT scanning protocols for children who require multiple CT studies, such as those with craniosynostosis. To evaluate the utility of ultra-low-dose CT protocols with model-based iterative reconstruction techniques for craniosynostosis imaging. We scanned two pediatric anthropomorphic phantoms with a 64-slice CT scanner using different low-dose protocols for craniosynostosis. We measured organ doses in the head region with metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters. Numerical simulations served to estimate organ and effective doses. We objectively and subjectively evaluated the quality of images produced by adaptive statistical iterative reconstruction (ASiR) 30%, ASiR 50% and Veo (all by GE Healthcare, Waukesha, WI). Image noise and contrast were determined for different tissues. Mean organ dose with the newborn phantom was decreased up to 83% compared to the routine protocol when using ultra-low-dose scanning settings. Similarly, for the 5-year phantom the greatest radiation dose reduction was 88%. The numerical simulations supported the findings with MOSFET measurements. The image quality remained adequate with Veo reconstruction, even at the lowest dose level. Craniosynostosis CT with model-based iterative reconstruction could be performed with a 20-μSv effective dose, corresponding to the radiation exposure of plain skull radiography, without compromising required image quality. (orig.)

  12. Is PET/CT efficient tool to evaluate the response after stereotactic radiation therapy for pancreas cancer?

    International Nuclear Information System (INIS)

    Kim, Mi Sook; Yoo, Seong Yul; Cho, Chul Koo

    2005-01-01

    In pancreas cancer, to evaluate the efficacy of PET/CT as tool to check the response after stereotactic radiation therapy and to define functional imaging role of PET/CT as alterative tool of computed tomography. From November 2003 to December 2004, among locally advanced pancreas cancer patients treated by stereotactic radiation therapy using CyberKnife(CK), 14 were evaluated by PET/CT before and after treatment. Four patients took PET/CT one month after CK, 4 patients 2 months after CK, and 6 patients 3 months after CK as the first evaluation of treatment. All of patients were also evaluated by CT or CA19-9 tumor antigen with the range of 1-2 months after CK. In addition of PET/CT to CT, lymph node metastasis were revealed as positive in 4 patients who had negative finding on CT. Furthermore, patients who showed partial or complete response on PET/CT findings that checked within 3 months after CK have significantly longer median survival time than patients who showed no response or disease progression(13 months and 9 months, respectively). Responses based on CA19-9 tumor antigen or CT, however, showed no significant difference in terms of median survival time. PET/CT can provide more information for lymph node metastasis compared to CT alone. It is very helpful for delineation of tumor extent for CK planning. And initial response on PET/CT scan could be a significant prognostic factor rather than response on CA19-9 level or CT. In the future, more study is necessary to evaluate if PET/CT could substitute CT and finally CT could be omitted during follow-up period after CK

  13. Changes of intrathoracic extrapulmonary organs after radiation therapy for lung and esophageal cancer:CT findings

    International Nuclear Information System (INIS)

    Song, Kyeong Seop; Kim, Sung Jin; Park, Woo Yoon; Hun, Bae Il; Han, Gi Seok; Cha, Sang Hun; Park, Kil Sun

    2001-01-01

    To evaluate the CT findings and incidence of complications occurring in intrathoracic extrapulmonary organs due to radiation therapy. Among 82 patients who underwent chest CT before and after radiation therapy, 23, in whom the procedure provided no evidence of pericardial invasion or pleural effusion before radiation therapy, nor of significant improvement in the tumor after this therapy, were evaulated. Changes in the pericardium, pleura and mediastinal fat were retrospectively assessed. In comparing the CT findings obtained before radiation therapy with those obtained afterwards, changes in the pericardium and pleura were classified as effusion where low density fluid was present and as thickening where there was no fluid. If an increased abundance of soft tissue strands was seen within mediastinal fat, changes in this fat were deemed to have occurred. Among the 23 patients evaluated, changes in the pericardium [thickening (n=3 ; 13.0%) ; effusion (n=8 ; 34.8%)] were found in 11 patients (47.8%), and changes in the pleura [thickening (n=3 ; 13.1%); effusion (n=9 ; 39.1%)] in 12 (52.2%). In no patient with pericardial or pleural effusion was thickening or contrast enhancement of the pericardium or pleura evident. In seven cases(30.4%), soft tissue strands within mediastinal fat had become more abundant. The CT findings which demonstrated complications resulting from radiation therapy were pericardial or pleural thickening or effusion and an increased abundance of soft tissue strands within mediastinal fat. In contrast to previous reports, pericardial and pleural change after radiation therapy was a common finding in our study, occurring in 69.6% of cases

  14. Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utility

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Franziska M.; Johnson, Thorsten R.C.; Sommer, Wieland H.; Thierfelder, Kolja M.; Meinel, Felix G. [University Hospital Munich, Institute for Clinical Radiology, Munich (Germany)

    2015-06-01

    To determine the radiation dose, image quality, and clinical utility of non-enhanced chest CT with spectral filtration. We retrospectively analysed 25 non-contrast chest CT examinations acquired with spectral filtration (tin-filtered Sn100 kVp spectrum) compared to 25 examinations acquired without spectral filtration (120 kV). Radiation metrics were compared. Image noise was measured. Contrast-to-noise-ratio (CNR) and figure-of-merit (FOM) were calculated. Diagnostic confidence for the assessment of various thoracic pathologies was rated by two independent readers. Effective chest diameters were comparable between groups (P = 0.613). In spectral filtration CT, median CTDI{sub vol}, DLP, and size-specific dose estimate (SSDE) were reduced (0.46 vs. 4.3 mGy, 16 vs. 141 mGy*cm, and 0.65 vs. 5.9 mGy, all P < 0.001). Spectral filtration CT had higher image noise (21.3 vs. 13.2 HU, P < 0.001) and lower CNR (47.2 vs. 75.3, P < 0.001), but was more dose-efficient (FOM 10,659 vs. 2,231/mSv, P < 0.001). Diagnostic confidence for parenchymal lung disease and osseous pathologies was lower with spectral filtration CT, but no significant difference was found for pleural pathologies, pulmonary nodules, or pneumonia. Non-contrast chest CT using spectral filtration appears to be sufficient for the assessment of a considerable spectrum of thoracic pathologies, while providing superior dose efficiency, allowing for substantial radiation dose reduction. (orig.)

  15. Automatic Segmentation and Online virtualCT in Head-and-Neck Adaptive Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Peroni, Marta, E-mail: marta.peroni@mail.polimi.it [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Ciardo, Delia [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Spadea, Maria Francesca [Department of Experimental and Clinical Medicine, Universita degli Studi Magna Graecia, Catanzaro (Italy); Riboldi, Marco [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Comi, Stefania; Alterio, Daniela [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Baroni, Guido [Department of Bioengineering, Politecnico di Milano, Milano (Italy); Bioengineering Unit, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy); Orecchia, Roberto [Advanced Radiotherapy Center, European Institute of Oncology, Milano (Italy); Universita degli Studi di Milano, Milano (Italy); Medical Department, Centro Nazionale di Adroterapia Oncologica, Pavia (Italy)

    2012-11-01

    Purpose: The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. Method: We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Results: Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. Conclusion: The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization.

  16. Automatic segmentation and online virtualCT in head-and-neck adaptive radiation therapy.

    Science.gov (United States)

    Peroni, Marta; Ciardo, Delia; Spadea, Maria Francesca; Riboldi, Marco; Comi, Stefania; Alterio, Daniela; Baroni, Guido; Orecchia, Roberto

    2012-11-01

    The purpose of this work was to develop and validate an efficient and automatic strategy to generate online virtual computed tomography (CT) scans for adaptive radiation therapy (ART) in head-and-neck (HN) cancer treatment. We retrospectively analyzed 20 patients, treated with intensity modulated radiation therapy (IMRT), for an HN malignancy. Different anatomical structures were considered: mandible, parotid glands, and nodal gross tumor volume (nGTV). We generated 28 virtualCT scans by means of nonrigid registration of simulation computed tomography (CTsim) and cone beam CT images (CBCTs), acquired for patient setup. We validated our approach by considering the real replanning CT (CTrepl) as ground truth. We computed the Dice coefficient (DSC), center of mass (COM) distance, and root mean square error (RMSE) between correspondent points located on the automatically segmented structures on CBCT and virtualCT. Residual deformation between CTrepl and CBCT was below one voxel. Median DSC was around 0.8 for mandible and parotid glands, but only 0.55 for nGTV, because of the fairly homogeneous surrounding soft tissues and of its small volume. Median COM distance and RMSE were comparable with image resolution. No significant correlation between RMSE and initial or final deformation was found. The analysis provides evidence that deformable image registration may contribute significantly in reducing the need of full CT-based replanning in HN radiation therapy by supporting swift and objective decision-making in clinical practice. Further work is needed to strengthen algorithm potential in nGTV localization. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. The Utility of PET/CT in the Planning of External Radiation Therapy for Prostate Cancer.

    Science.gov (United States)

    Calais, Jeremie; Cao, Minsong; Nickols, Nicholas G

    2018-04-01

    Radiotherapy and radical prostatectomy are the definitive treatment options for patients with localized prostate cancer. A rising level of prostate-specific antigen after radical prostatectomy indicates prostate cancer recurrence, and these patients may still be cured with salvage radiotherapy. To maximize chance for cure, the irradiated volumes should completely encompass the extent of disease. Therefore, accurate estimation of the location of disease is critical for radiotherapy planning in both the definitive and the salvage settings. Current first-line imaging for prostate cancer has limited sensitivity for detection of disease both at initial staging and at biochemical recurrence. Integration of PET into routine evaluation of prostate cancer patients may improve both staging accuracy and radiotherapy planning. 18 F-FDG PET/CT is now routinely used in radiation planning for several cancer types. However, 18 F-FDG PET/CT has low sensitivity for prostate cancer. Additional PET probes evaluated in prostate cancer include 18 F-sodium fluoride, 11 C-acetate, 11 C- or 18 F-choline, 18 F-fluciclovine, and 68 Ga- or 18 F-labeled ligands that bind prostate-specific membrane antigen (PSMA). PSMA ligands appear to be the most sensitive and specific but have not yet received Food and Drug Administration New Drug Application approval for use in the United States. Retrospective and prospective investigations suggest a potential major impact of PET/CT on prostate radiation treatment planning. Prospective trials randomizing patients to routine radiotherapy planning versus PET/CT-aided planning may show meaningful clinical outcomes. Prospective clinical trials evaluating the addition of 18 F-fluciclovine PET/CT for planning of salvage radiotherapy with clinical endpoints are under way. Prospective trials evaluating the clinical impact of PSMA PET/CT on prostate radiation planning are indicated. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Impact of view reduction in CT on radiation dose for patients

    International Nuclear Information System (INIS)

    Parcero, E.; Flores, L.; Sánchez, M.G.; Vidal, V.; Verdú, G.

    2017-01-01

    Iterative methods have become a hot topic of research in computed tomography (CT) imaging because of their capacity to resolve the reconstruction problem from a limited number of projections. This allows the reduction of radiation exposure on patients during the data acquisition. The reconstruction time and the high radiation dose imposed on patients are the two major drawbacks in CT. To solve them effectively we adapted the method for sparse linear equations and sparse least squares (LSQR) with soft threshold filtering (STF) and the fast iterative shrinkage-thresholding algorithm (FISTA) to computed tomography reconstruction. The feasibility of the proposed methods is demonstrated numerically. - Highlights: • A method for CT reconstruction is proposed: LSQR-STF-FISTA. • Our method achieve good results in reconstruction of few-view CT. • The reconstruction of projections with Gaussian noise is possible. • Our reconstruction process allows a reduction of time in the data acquisition process. • Our reconstruction process allows a reduction in the radiation exposure in the patients.

  19. Dose profile variation with voltage in head CT scans using radiochromic films

    Science.gov (United States)

    Mourão, A. P.; Alonso, T. C.; DaSilva, T. A.

    2014-02-01

    The voltage source used in an X-ray tube is an important part of defining the generated beam spectrum energy profile. The X-ray spectrum energy defines the X-ray beam absorption as well as the characteristics of the energy deposition in an irradiated object. Although CT scanners allow one to choose between four different voltage values, most of them employ a voltage of 120 kV in their scanning protocols, regardless of the patient characteristics. Based on this fact, this work investigated the deposited dose in a polymethyl methacrylate (PMMA) cylindrical head phantom. The entire volume was irradiated twice. Two CT scanning protocols were used with two different voltage values: 100 and 120 kV. The phantom volume was irradiated, and radiochromic films were employed to record dose profiles. Measurements were conducted with a calibrated pencil ionization chamber, which was positioned in the center and in four peripheral bores of the head PMMA phantom, to calibrate the radiochromic films. The central slice was then irradiated. This procedure allowed us to find the conversion factors necessary to obtain dose values recorded in the films. The data obtained allowed us to observe the dose variation profile inside the phantom head as well as in the peripheral and central regions. The peripheral region showed higher dose values than those of the central region for scans using both voltage values: approximately 31% higher for scanning with 120 kV and 25% higher with 100 kV. Doses recorded with the highest voltage are significantly higher, approximately 50% higher in the peripheral region and 40% higher in the central region. A longitudinal variation could be observed, and the maximum dose was recorded at the peripheral region, at the midpoint of the longitudinal axis. The obtained results will most likely contribute to the dissemination of proper procedure as well as to optimize dosimetry and tests of quality control in CT because the choice of protocols with different voltage

  20. Radiation dosimetry and its influencing factors for the multi-detector/slice spiral CT

    International Nuclear Information System (INIS)

    Bai Mei; Zheng Junzheng

    2008-01-01

    The Multi-Detector/Slice Spiral Computed Tomography (MDCT/MSCT)reflects the new progress in equipment and technology for radiology. Its popularized application demonstrates its advantages for clinical diagnosis. With the continuous development and growing uses of the MDCT/MSCT, the medical exposure of the patients and public has also been increasing. Therefore, assessment of the radiation dose and radiation risk from X-CT has become an increasingly important concern that should be addressed. Thus, this paper summarizes the main characteristics of the MDCT/MSCT emphasizing particularly on the radiation dosimetry, and reviews the expressions and measures of radiation dose in the MDCT/MSCT. In addition, main factors that influence radiation dose from the MDCT/MSCT are also discussed. A proper grasp of its radiation dosimetry and assessment method can significantly help radiologists, health physicists, medical physicists, X-CT engineers and manufacturers improve the management of radiation dose while optimizing the image quality in the MDCT/MSCT. (authors)

  1. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    OpenAIRE

    Livingstone Roshan; Pradip Joe; Dinakran Paul; Srikanth B

    2010-01-01

    Objective: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tu...

  2. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    Science.gov (United States)

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  3. System for verifiable CT radiation dose optimization based on image quality. part II. process control system.

    Science.gov (United States)

    Larson, David B; Malarik, Remo J; Hall, Seth M; Podberesky, Daniel J

    2013-10-01

    To evaluate the effect of an automated computed tomography (CT) radiation dose optimization and process control system on the consistency of estimated image noise and size-specific dose estimates (SSDEs) of radiation in CT examinations of the chest, abdomen, and pelvis. This quality improvement project was determined not to constitute human subject research. An automated system was developed to analyze each examination immediately after completion, and to report individual axial-image-level and study-level summary data for patient size, image noise, and SSDE. The system acquired data for 4 months beginning October 1, 2011. Protocol changes were made by using parameters recommended by the prediction application, and 3 months of additional data were acquired. Preimplementation and postimplementation mean image noise and SSDE were compared by using unpaired t tests and F tests. Common-cause variation was differentiated from special-cause variation by using a statistical process control individual chart. A total of 817 CT examinations, 490 acquired before and 327 acquired after the initial protocol changes, were included in the study. Mean patient age and water-equivalent diameter were 12.0 years and 23.0 cm, respectively. The difference between actual and target noise increased from -1.4 to 0.3 HU (P process control chart identified several special causes of variation. Implementation of an automated CT radiation dose optimization system led to verifiable simultaneous decrease in image noise variation and SSDE. The automated nature of the system provides the opportunity for consistent CT radiation dose optimization on a broad scale. © RSNA, 2013.

  4. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Liao, S; Wang, Y; Weng, H [Chiayi Chang Gung Memorial Hospital of The C.G.M.F, Puzi City, Chiayi County, Taiwan (China)

    2015-06-15

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle.

  5. SU-E-P-11: Comparison of Image Quality and Radiation Dose Between Different Scanner System in Routine Abdomen CT

    International Nuclear Information System (INIS)

    Liao, S; Wang, Y; Weng, H

    2015-01-01

    Purpose To evaluate image quality and radiation dose of routine abdomen computed tomography exam with the automatic current modulation technique (ATCM) performed in two different brand 64-slice CT scanners in our site. Materials and Methods A retrospective review of routine abdomen CT exam performed with two scanners; scanner A and scanner B in our site. To calculate standard deviation of the portal hepatic level with a region of interest of 12.5 mm x 12.5mm represented to the image noise. The radiation dose was obtained from CT DICOM image information. Using Computed tomography dose index volume (CTDIv) to represented CT radiation dose. The patient data in this study were with normal weight (about 65–75 Kg). Results The standard deviation of Scanner A was smaller than scanner B, the scanner A might with better image quality than scanner B. On the other hand, the radiation dose of scanner A was higher than scanner B(about higher 50–60%) with ATCM. Both of them, the radiation dose was under diagnostic reference level. Conclusion The ATCM systems in modern CT scanners can contribute a significant reduction in radiation dose to the patient. But the reduction by ATCM systems from different CT scanner manufacturers has slightly variation. Whatever CT scanner we use, it is necessary to find the acceptable threshold of image quality with the minimum possible radiation exposure to the patient in agreement with the ALARA principle

  6. Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

    Energy Technology Data Exchange (ETDEWEB)

    Li Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Toncheva, Greta; Yoshizumi, Terry T.; Frush, Donald P. [Medical Physics Graduate Program, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Medical Physics Graduate Program, Department of Physics, and Department of Biomedical Engineering, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 and Department of Biomedical Engineering, University of North Carolina, Chapel Hill, North Carolina 27599 (United States); Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Duke Radiation Dosimetry Laboratory, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27705 (United States); Duke Radiation Dosimetry Laboratory, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Division of Pediatric Radiology, Department of Radiology, Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2011-01-15

    Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller

  7. Structural acoustics model of the violin radiativity profile.

    Science.gov (United States)

    Bissinger, George

    2008-12-01

    Violin radiativity profiles are dominated by the Helmholtz-like A0 cavity mode ( approximately 280 Hz), first corpus bending modes B1(-) and B1(+) ( approximately 500 Hz), and BH and bridge-filter peaks ( approximately 2.4 kHz and approximately 3.5 kHz, respectively), with falloff above approximately 4 kHz. The B1 modes-dependent on two low-lying free-plate modes--are proposed to excite A0 via coupling to B1-driven in-phase f-hole volume flows. VIOCADEAS data show that A0 radiativity increases primarily as A0-B1(-) frequency difference decreases, consistent with Meinel's 1937 experiment for too-thick/too-thin plate thicknesses, plus sound post removal and violin octet baritone results. The vibration-->acoustic energy filter, F(RAD), computed from shape-material-independent radiation and total damping, peaks at the critical frequency f(crit), estimated from a free-plate mode by analogy to flat-plate bending. Experimentally, f(crit) decreased as this plate mode (and B1(+)) frequency increased. Simulations show that increasing plate thicknesses lowers f(crit), reduces F(RAD), and moves the spectral balance toward lower frequencies. Incorporating string-->corpus filters (including bridge versus bridge-island impedances) provides a model for overall violin radiativity. This model-with B1 and A0-B1 couplings, and f(crit) (computed from a free-plate mode important to B1) strongly affecting the lowest and highest parts of the radiativity profile-substantiates prior empirical B1--sound quality linkages.

  8. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Bastarrika, Gorka [Dept. of Radiology, Clinica Univ. de Navarra, Pamplona (Spain); Cardiac Imaging Unit, Clinica Univ. de Navarra, Pamplona (Spain)], e-mail: bastarrika@unav.es

    2012-06-15

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 {+-} 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 {+-} 58.3 mL) with respect to ECG-gated CT (142.7 {+-} 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 {+-} 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols.

  9. Feasibility of epicardial adipose tissue quantification in non-ECG-gated low-radiation-dose CT: comparison with prospectively ECG-gated cardiac CT

    International Nuclear Information System (INIS)

    Simon-Yarza, Isabel; Viteri-Ramirez, Guillermo; Saiz-Mendiguren, Ramon; Slon-Roblero, Pedro J.; Paramo, Maria; Bastarrika, Gorka

    2012-01-01

    Background: Epicardial adipose tissue (EAT) is an important indicator of cardiovascular risk. This parameter is generally assessed on ECG-gated computed tomography (CT) images. Purpose: To evaluate feasibility and reliability of EAT quantification on non-gated thoracic low-radiation-dose CT examinations with respect to prospectively ECG-gated cardiac CT acquisition. Material and Methods: Sixty consecutive asymptomatic smokers (47 men; mean age 64 ± 9.8 years) underwent low-dose CT of the chest and prospectively ECG-gated cardiac CT acquisitions (64-slice dual-source CT). The two examinations were reconstructed with the same range, field of view, slice thickness, and convolution algorithm. Two independent observers blindly quantified EAT volume using commercially available software. Data were compared with paired sample Student t-test, concordance correlation coefficients (CCC), and Bland-Altman plots. Results: No statistically significant difference was observed for EAT volume quantification with low-dose-CT (141.7 ± 58.3 mL) with respect to ECG-gated CT (142.7 ± 57.9 mL). Estimation of CCC showed almost perfect concordance between the two techniques for EAT-volume assessment (CCC, 0.99; mean difference, 0.98 ± 5.1 mL). Inter-observer agreement for EAT volume estimation was CCC: 0.96 for low-dose-CT examinations and 0.95 for ECG-gated CT. Conclusion: Non-gated low-dose CT allows quantifying EAT with almost the same concordance and reliability as using dedicated prospectively ECG-gated cardiac CT acquisition protocols

  10. Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality.

    Science.gov (United States)

    Shah, Amisha; Rees, Mitchell; Kar, Erica; Bolton, Kimberly; Lee, Vincent; Panigrahy, Ashok

    2018-06-01

    For the past several years, increased levels of imaging radiation and cumulative radiation to children has been a significant concern. Although several measures have been taken to reduce radiation dose during computed tomography (CT) scan, the newer dose reduction software adaptive statistical iterative reconstruction (ASIR) has been an effective technique in reducing radiation dose. To our knowledge, no studies are published that assess the effect of ASIR on extremity CT scans in children. To compare radiation dose, image noise, and subjective image quality in pediatric lower extremity CT scans acquired with and without ASIR. The study group consisted of 53 patients imaged on a CT scanner equipped with ASIR software. The control group consisted of 37 patients whose CT images were acquired without ASIR. Image noise, Computed Tomography Dose Index (CTDI) and dose length product (DLP) were measured. Two pediatric radiologists rated the studies in subjective categories: image sharpness, noise, diagnostic acceptability, and artifacts. The CTDI (p value = 0.0184) and DLP (p value ASIR compared with non-ASIR studies. However, the subjective ratings for sharpness (p ASIR images (p ASIR CT studies. Adaptive statistical iterative reconstruction reduces radiation dose for lower extremity CTs in children, but at the expense of diagnostic imaging quality. Further studies are warranted to determine the specific utility of ASIR for pediatric musculoskeletal CT imaging.

  11. Computation of thyroid doses and carcinogenic radiation risks to patients undergoing neck CT examinations

    International Nuclear Information System (INIS)

    Huda, W.; Spampinato, M. V.; Tipnis, S. V.; Magill, D.

    2013-01-01

    The aim of the study was to investigate how differences in patient anatomy and CT technical factors in neck CT impact on thyroid doses and the corresponding carcinogenic risks. The CTDI vol and dose-length product used in 11 consecutive neck CT studies, as well as data on automatic exposure control (AEC) tube current variation(s) from the image DICOM header, were recorded. For each CT image that included the thyroid, the mass equivalent water cylinder was estimated based on the patient cross-sectional area and average relative attenuation coefficient (Hounsfield unit, HU). Patient thyroid doses were estimated by accounting for radiation intensity at the location of the patient's thyroid, patient size and the scan length. Thyroid doses were used to estimate thyroid cancer risks as a function of patient demographics using risk factors in BEIR VII. The length of the thyroid glands ranged from 21 to 54 mm with an average length of 42±12 mm. Water cylinder diameters corresponding to the central slice through the patient thyroid ranged from 18 to 32 cm with a mean of 25±5 cm. The average CTDI vol (32-cm phantom) used to perform these scans was 26±6 mGy, but the use of an AEC increased the tube current by an average of 44 % at the thyroid mid-point. Thyroid doses ranged from 29 to 80 mGy, with an average of 55±19 mGy. A 20-y-old female receiving the highest thyroid dose of 80 mGy would have a thyroid cancer risk of nearly 0.1 %, but radiation risks decreased very rapidly with increasing patient age. The key factors that affect thyroid doses in neck CT examinations are the radiation intensity at the thyroid location and the size of the patient. The corresponding patient thyroid cancer risk is markedly influenced by patient sex and age. (authors)

  12. Radiation dose from multidetector CT studies in children: results from the first Italian nationwide survey

    Energy Technology Data Exchange (ETDEWEB)

    Granata, Claudio [IRCCS Istituto Giannina Gaslini, Department of Radiology, Genoa (Italy); Origgi, Daniela; Palorini, Federica [Istituto Europeo di Oncologia, Department of Medical Physics, Milan (Italy); Matranga, Domenica [University of Palermo, Department of Sciences for Health Promotion and Mother and Child Care ' ' G. D' Alessandro' ' , Palermo (Italy); Salerno, Sergio [University of Palermo, Department of Medical and Forensic Biopathology and Biotechnologies, Section of Radiology, Palermo (Italy)

    2015-05-01

    Multidetector CT (MDCT) scanners have contributed to the widespread use of CT in paediatric imaging. However, concerns are raised for the associated radiation exposure. Very few surveys on radiation exposure from MDCT studies in children are available. The aim of this study was to outline the status of radiation exposure in children from MDCT practice in Italy. In this retrospective multicentre study we asked Italian radiology units with an MDCT scanner with at least 16 slices to provide dosimetric and acquisition parameters of CT examinations in three age groups (1-5, 6-10, 11-15 years) for studies of head, chest and abdomen. The dosimetric results were reported in terms of third-quartile volumetric CT dose index (CTDI{sub vol}) (mGy), size-specific dose estimate (SSDE) (mGy), dose length product (DLP) (mGy cm), and total DLP for multiphase studies. These results were compared with paediatric European and adult Italian published data. A multivariate analysis assessed the association of CTDI{sub vol} with patient characteristics and scanning modalities. We collected data from 993 MDCT examinations performed at 25 centres. For age groups 1-5 years, 6-10 years and 11-15 years, the CTDI{sub vol}, DLP and total DLP values were statistically significantly below the values observed in our analogous national survey in adults, although the difference decreased with increasing age. CTDI{sub vol} variability among centres was statistically significant (variance = 0.07; 95% confidence interval = 0.03-0.16; P < 0.001). This study reviewed practice in Italian centres performing paediatric imaging with MDCT scanners. The variability of doses among centres suggests that the use of standardised CT protocols should be encouraged. (orig.)

  13. Radiation-induced malignant tumours: a specific cytogenetic profile?

    International Nuclear Information System (INIS)

    Chauveinc, L.; Gaboriaux, G.; Dutrillaux, A. M.; Dutrillaux, B.; Chauveinc, L.; Ricoul, M.; Sabatier, L.; Dutrillaux, B.

    1997-01-01

    To date, there is no criterion enabling to determine the spontaneous or radio-induced origin of malignant tumour occurring in a previously irradiated patient. Biological studies are rare. The cytogenetic data which could be found in the literature for eleven radio-induced tumours suggest that aneuploidies and polyclonality are frequent events. We studied, by R-Banding cytogenetic technique, five patients with short-term cultures (3 cases), short and long-term cultures (1 case) and xeno-grafting on nude pattern a high rate of balanced translocations, numerous random break points and a polyclonal evolution (10 clones). All other tumours, including the xeno-grafting sarcoma, had a monoclonal profile with complex karyotypes, hypo-diploid formulas and many deletions. These results show that the mechanism of radiation-induced tumours frequently involves chromosomes losses and deletions. The most likely explanation is that these alterations unmask radiation induced recessive mutations of tumour suppressor genes. (authors)

  14. Radiation dose and cancer risk estimates in helical CT for pulmonary tuberculosis infections

    Directory of Open Access Journals (Sweden)

    Adeleye Bamise

    2017-12-01

    Full Text Available The preference for computed tomography (CT for the clinical assessment of pulmonary tuberculosis (PTB infections has increased the concern about the potential risk of cancer in exposed patients. In this study, we investigated the correlation between cancer risk and radiation doses from different CT scanners, assuming an equivalent scan protocol. Radiation doses from three 16-slice units were estimated using the CT-Expo dosimetry software version 2.4 and standard CT scan protocol for patients with suspected PTB infections. The lifetime risk of cancer for each scanner was determined using the methodology outlined in the BEIR VII report. Organ doses were significantly different (P < 0.05 between the scanners. The calculated effective dose for scanner H2 is 34% and 37% higher than scanners H3 and H1 respectively. A high and statistically significant correlation was observed between estimated lifetime cancer risk for both male (r2 = 0.943, P < 0.05 and female patients (r2 = 0.989, P < 0.05. The risk variation between the scanners was slightly higher than 2% for all ages but was much smaller for specific ages for male and female patients (0.2% and 0.7%, respectively. These variations provide an indication that the use of a scanner optimizing protocol is imperative.

  15. Poster - 03: How to manage a nuclear medicine PET-CT for radiation oncology patients

    Energy Technology Data Exchange (ETDEWEB)

    Hinse, Martin; Létourneau, Étienne; Duplan, Danny; Piché, Émilie; Rivière, Rose Nerla; Bouchard, Guillaume [Centre Intégré de Cancérologie de Laval (Canada)

    2016-08-15

    Purpose: Development of an adapted multidisciplinary procedure designed to optimize the clinical workflow between radiation therapy (RT) and nuclear medicine (NM) for a PET-CT located in the NM department. Methods : The radiation oncologist (RO) prescribes the PET-CT exam and the clinical RT therapist gives all the necessary information to the patient prior to the exam. The immobilization accessories are prepared in the RT department. The RT and NM therapists work together for radiotracer injection, patient positioning and scan acquisition. The nuclear medicine physician (NMP) will study the images, draw Biological Target Volumes (BTVs) and produce a full exam report. Results : All tasks related to a planning PET-CT are done within 48 hours from the request by the RO to the reception of the images with the NMP contours and report. Conclusions : By developing a complete procedure collectively between the RT and NM departments, the patient benefits of a quick access to a RT planning PET-CT exam including the active involvement of every medical practitioners in these fields.

  16. Radiation dose and cancer risk estimates in helical CT for pulmonary tuberculosis infections

    Science.gov (United States)

    Adeleye, Bamise; Chetty, Naven

    2017-12-01

    The preference for computed tomography (CT) for the clinical assessment of pulmonary tuberculosis (PTB) infections has increased the concern about the potential risk of cancer in exposed patients. In this study, we investigated the correlation between cancer risk and radiation doses from different CT scanners, assuming an equivalent scan protocol. Radiation doses from three 16-slice units were estimated using the CT-Expo dosimetry software version 2.4 and standard CT scan protocol for patients with suspected PTB infections. The lifetime risk of cancer for each scanner was determined using the methodology outlined in the BEIR VII report. Organ doses were significantly different (P < 0.05) between the scanners. The calculated effective dose for scanner H2 is 34% and 37% higher than scanners H3 and H1 respectively. A high and statistically significant correlation was observed between estimated lifetime cancer risk for both male (r2 = 0.943, P < 0.05) and female patients (r2 = 0.989, P < 0.05). The risk variation between the scanners was slightly higher than 2% for all ages but was much smaller for specific ages for male and female patients (0.2% and 0.7%, respectively). These variations provide an indication that the use of a scanner optimizing protocol is imperative.

  17. High power beam profile monitor with optical transition radiation

    International Nuclear Information System (INIS)

    Denard, J.C.; Piot, P.; Capek, K.; Feldl, E.

    1997-01-01

    A simple monitor has been built to measure the profile of the high power beam (800 kW) delivered by the CEBAF accelerator at Jefferson Lab. The monitor uses the optical part of the forward transition radiation emitted from a thin carbon foil. The small beam size to be measured, about 100 μm, is challenging not only for the power density involved but also for the resolution the instrument must achieve. An important part of the beam instrumentation community believes the radiation being emitted into a cone of characteristic angle 1/γ is originated from a region of transverse dimension roughly λγ; thus the apparent size of the source of transition radiation would become very large for highly relativistic particles. This monitor measures 100 μm beam sizes that are much smaller than the 3.2 mm λγ limit; it confirms the statement of Rule and Fiorito that optical transition radiation can be used to image small beams at high energy. The present paper describes the instrument and its performance. The authors tested the foil in, up to 180 μA of CW beam without causing noticeable beam loss, even at 800 MeV, the lowest CEBAF energy

  18. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  19. Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review

    International Nuclear Information System (INIS)

    Chawla, Soni C.; Federman, Noah; Zhang, Di; Nagata, Kristen; Nuthakki, Soujanya; McNitt-Gray, Michael; Boechat, M.I.

    2010-01-01

    The increasing use of serial PET/CT scans in the management of pediatric malignancies raises the important consideration of radiation exposure in children. To estimate the cumulative radiation dose from PET/CT studies to children with malignancy and to compare with the data in literature. Two hundred forty-eight clinical PET/CT studies performed on 78 patients (50 boys/28 girls, 1.3 to 18 years old from December 2002 to October 2007) were retrospectively reviewed under IRB approval. The whole-body effective dose (ED) estimates for each child were obtained by estimating the effective dose from each PET/CT exam performed using the ImPACT Patient Dosimetry Calculator for CT and OLINDA for PET. The average number of PET/CT studies was 3.2 per child (range: 1 to 14 studies). The average ED of an individual CT study was 20.3 mSv (range: 2.7 to 54.2), of PET study was 4.6 mSv (range: 0.4 to 7.7) and of PET/CT study was 24.8 mSv (range: 6.2 to 60.7). The average cumulative radiation dose per patient from CT studies was 64.4 mSv (range: 2.7 to 326), from PET studies was 14.5 mSv (range: 2.8 to 73) and from PET/CT studies was 78.9 mSv (range: 6.2 to 399). The radiation exposure from serial PET/CT studies performed in pediatric malignancies was considerable; however, lower doses can be used for both PET and CT studies. The ALARA principle must be applied without sacrificing diagnostic information. (orig.)

  20. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California 90095 (United States); Department of Radiation Oncology, University of California San Diego, San Diego, California 92093 (United States); Philips Healthcare System, Cleveland, Ohio 44143 (United States); Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States)

    2012-12-15

    Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose

  1. Radiation protection in CT pelvis in Fantoma Rando by thermoluminescent dosimetry.

    Science.gov (United States)

    Madrid-González, O A; Rivera-Montalvo, T; Azorín-Nieto, J

    2012-12-01

    This paper presents results of equivalent dose organ determining to both primary beam and scattered radiation in a computed tomography (CT) procedures. All measurements were carried out to abdomen and critical organ (gonads) area. Selected dosimeters showed a standard deviation of 4.1% below to the reference values established by international guide lines. The equivalent dose in gonads was 14.27 mGy. Copyright © 2012. Published by Elsevier Ltd.

  2. A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators

    International Nuclear Information System (INIS)

    McNiven, Andrea; Kron, Tomas; Van Dyk, Jake

    2004-01-01

    Purpose: The evolution of three-dimensional conformal radiation treatment has led to the use of multileaf collimators (MLCs) in intensity-modulated radiation therapy (IMRT) and other treatment techniques to increase the conformity of the dose distribution. A new quality assurance (QA) phantom has been designed to check the handling of MLC settings in treatment planning and delivery. Methods and materials: The phantom consists of a Perspex block with stepped edges that can be rotated in all planes. The design allows for the assessment of several MLC and micro-MLC types from various manufacturers, and is therefore applicable to most radiation therapy institutions employing MLCs. The phantom is computed tomography (CT) scanned as is a patient, and QA assessments can be made of field edge display for a variety of shapes and orientations on both radiation treatment planning systems (RTPS) and computed tomography simulators. Results: The dimensions of the phantom were verified to be physically correct within an uncertainty range of 0-0.7 mm. Errors in leaf position larger than 1 mm were easily identified by multiple observers. Conclusions: The MLC geometry phantom is a useful tool in the QA of radiation therapy with application to RTPS, CT simulators, and virtual simulation packages with MLC display capabilities

  3. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    International Nuclear Information System (INIS)

    Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz; Bauk, Sabar; Hashim, Rokiah

    2015-01-01

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ 2 value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ 2 value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies

  4. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Mohd Fahmi Mohd, E-mail: mfahmi@usm.my; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz [School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Bauk, Sabar [School of Distance Education, Universiti Sains Malaysia, 11800 Penang (Malaysia); Hashim, Rokiah [School of Industrial Technologies, Universiti Sains Malaysia, 11800 Penang (Malaysia)

    2015-04-29

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ{sup 2} value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ{sup 2} value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.

  5. MO-G-18A-01: Radiation Dose Reducing Strategies in CT, Fluoroscopy and Radiography

    International Nuclear Information System (INIS)

    Mahesh, M; Gingold, E; Jones, A

    2014-01-01

    Advances in medical x-ray imaging have provided significant benefits to patient care. According to NCRP 160, there are more than 400 million x-ray procedures performed annually in the United States alone that contributes to nearly half of all the radiation exposure to the US population. Similar growth trends in medical x-ray imaging are observed worldwide. Apparent increase in number of medical x-ray imaging procedures, new protocols and the associated radiation dose and risk has drawn considerable attention. This has led to a number of technological innovations such as tube current modulation, iterative reconstruction algorithms, dose alerts, dose displays, flat panel digital detectors, high efficient digital detectors, storage phosphor radiography, variable filters, etc. that are enabling users to acquire medical x-ray images at a much lower radiation dose. Along with these, there are number of radiation dose optimization strategies that users can adapt to effectively lower radiation dose in medical x-ray procedures. The main objectives of this SAM course are to provide information and how to implement the various radiation dose optimization strategies in CT, Fluoroscopy and Radiography. Learning Objectives: To update impact of technological advances on dose optimization in medical imaging. To identify radiation optimization strategies in computed tomography. To describe strategies for configuring fluoroscopic equipment that yields optimal images at reasonable radiation dose. To assess ways to configure digital radiography systems and recommend ways to improve image quality at optimal dose

  6. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  7. Dental-CT: image quality and absorbed radiation dose of different scan protocols

    International Nuclear Information System (INIS)

    Schorn, C.; Alamo, L.; Funke, M.; Grabbe, E.; Visser, H.; Hermann, K.P.

    1999-01-01

    Purpose: To develop a scan protocol for dental-CT which guarantees good image quality at the lowest possible radiation dose. Methods: In an experimental investigation Dental-CT (HSA, GE, Milwaukee, USA) of the mandible of two human skeletons positioned in a water tank were performed in order to define the most advantageous scan protocol. Tube currents ranged from 40 to 200 mA and the scan technique was modified (axial mode or helical mode with pitches of 1 to 3 and corresponding increments of 0.4 to 1.0 mm). 39 patients underwent a dental-CT with decreased current (80 mA) in the helical scan mode (pitch 2, slice thickness 1 mm). Dose measurements were performed for two different scan protocols (A: axial, 130 mAs, B: helical, 80 mA, pitch 2). Results: The preliminary investigations of image quality showed only a minor effect of the applied current. For the helical scan mode, pitches of more than 2 impaired image quality. A low increment had no advantages. There were no disadvantages in clinical practice using protocol B with decreased tube current. Absorbed radiation dose of dental CT performed with protocol B was decreased to one third in comparison to protocol A. Conclusions: A scan protocol with a low tube current (e.g., 80 mA, for a rotation time of 1 s) and a helical scan mode (e.g., for a slice thickness of 1 mm with a pitch of 2 and an increment of 1 mm) is recommended for performing dental-CT. (orig.) [de

  8. Reducing Radiation Dose in Adult Head CT using Iterative Reconstruction - A Clinical Study in 177 Patients.

    Science.gov (United States)

    Kaul, D; Kahn, J; Huizing, L; Wiener, E; Grupp, U; Böning, G; Ghadjar, P; Renz, D M; Streitparth, F

    2016-02-01

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n = 71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n = 86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n = 74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n = 20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n = 20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up. ASIR may reduce radiation significantly while maintaining adequate image quality. cCT protocol with 20 % ASIR and 40 %ASIR/60 %FBP blending is adequate for everyday clinical use. cCT protocol with 30 % ASIR and 50 %ASIR/50 %FBP blending is adequate for follow-up imaging © Georg Thieme Verlag KG Stuttgart · New York.

  9. Improved image quality and radiation dose reduction in liver dynamic CT scan with the protocol change

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yu Jin; Cho, Pyong Kon [Radiological Science, Catholic University of Daegu, Daegu (Korea, Republic of)

    2015-06-15

    The purpose is reducing radiation dose while maintaining of image quality in liver dynamic CT(LDCT) scan, by protocols generally used and the tube voltage set at a low level protocol compared to the radiation dose and image quality. The target is body mass index, 18.5-24 patients out of 40 patients who underwent the ACT(abdominal CT). Group A(tube voltage : 120 kVp, SAFIRE strength 1) of 20 people among 40 people, to apply the general abdominal CT scan protocol, group B(tube voltage : 100 kVp, apply SAFIRE strength 0-5) was 20 people, set a lower tube voltage. Image quality evaluation was setting a region of interest(ROI) in the liver parenchyma, aorta, superior mesenteric artery (SMA), celiac trunk, visceral fat of arterial phase. In the ROI were compared by measuring the noise, signal to noise ratio(SNR), contrast to noise ratio(CNR), CT number. In addition, qualitative assessments to evaluate two people in the rich professional experience in Radiology by 0-3 points. We compared the total radiation dose, dose length product(DLP) and effective dose, volume computed tomography dose index(CTDIvol). The higher SAFIRE in the tube voltage 100 kVp, noise is reduced, CT number was increased. Thus, SNR and CNR was increased higher the SAFIRE step. Compared with the tube voltage 120 kVp, noise, SNR, CNR was most similar in SAFIRE strength 2 and 3. Qualitative assessment SAFIRE strength 2 is the most common SAFIRE strength 2 the most common qualitative assessment, if the tube voltage of 100 kVp when the quality of the images better evaluated was SAFIRE strength 1. Dose was reduced from 21.69%, in 100 kVp than 120 kVp. In the case of a relatively high BMI is not LDCT scan, When it is shipped from the factory tube voltage is set higher, unnecessary radiation exposure when considering the reality that is concerned, when according to the results of this study, set a lower tube voltage and adjust the SAFIRE strength to 1 or 2, the radiation without compromising image quality

  10. SU-F-I-33: Estimating Radiation Dose in Abdominal Fat Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, X; Yang, K; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To compare size-specific dose estimate (SSDE) in abdominal fat quantitative CT with another dose estimate D{sub size,L} that also takes into account scan length. Methods: This study complied with the requirements of the Health Insurance Portability and Accountability Act. At our institution, abdominal fat CT is performed with scan length = 1 cm and CTDI{sub vol} = 4.66 mGy (referenced to body CTDI phantom). A previously developed CT simulation program was used to simulate single rotation axial scans of 6–55 cm diameter water cylinders, and dose integral of the longitudinal dose profile over the central 1 cm length was used to predict the dose at the center of one-cm scan range. SSDE and D{sub size,L} were assessed for 182 consecutive abdominal fat CT examinations with mean water-equivalent diameter (WED) of 27.8 cm ± 6.0 (range, 17.9 - 42.2 cm). Patient age ranged from 18 to 75 years, and weight ranged from 39 to 163 kg. Results: Mean SSDE was 6.37 mGy ± 1.33 (range, 3.67–8.95 mGy); mean D{sub size,L} was 2.99 mGy ± 0.85 (range, 1.48 - 4.88 mGy); and mean D{sub size,L}/SSDE ratio was 0.46 ± 0.04 (range, 0.40 - 0.55). Conclusion: The conversion factors for size-specific dose estimate in AAPM Report No. 204 were generated using 15 - 30 cm scan lengths. One needs to be cautious in applying SSDE to small length CT scans. For abdominal fat CT, SSDE was 80–150% higher than the dose of 1 cm scan length.

  11. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  12. Calculations and analysis of the radiation protection of PET/CT Center

    International Nuclear Information System (INIS)

    Ivanova, S.; Artinyan, A.

    2015-01-01

    Positron Emission Tomography (PET) has been available in number of centers for more than 25 years, but its use was not wide spread until 10 years ago. In Bulgarian PET/CT was installed for the first time in 2009 in Nuclear Medicine Department in University Hospital St. Marina in Varna, Bulgaria. As a physicists the aim for us was to consider and calculate the shielding so that to protect the people and the staff. The purpose of this paper is calculating and analysis of the radiation protection and shielding of Nuclear Medicine Center including PET/CT center situated in University Hospital St. Marina in Varna, Bulgaria. Following the Recommendation of International Commission of Radiation Protection (ICRP) Report 60, Report 73, American Association of Physics in Medicine (AAPM) Task Group 108: PET and PET/CT Shielding Requirements, Medical Physics, DIN 6844-3, Installation of Nuclear Medicine; Radiation protection calculation and the Bulgarian regulations in NM, the new Department was made. The design of the Existing Department was renovated following the requirements for PET/CT Center. The shielding was calculated for imaging room as well as the uptake room, resting room, the PET control room, places above and under the facility, patient WCs and other surrounding laboratories and stuff cabinets. The radiotracer used for the examinations is fluoro-2-desixyglucose (FDG). FDG is labeled with F-18, whose time of flight is only 109min, but it is positron emitting. The energy of annihilation is 511keV. The aim was achieved. The Department was opened. It is working now with about 15 patients every day. The dose rates measured with personal TLD’s for the last 5 years for the stuff are under 3mSv. As the average dose is around 1mSv, and the doses over 1mSv are only for nurses who injected the FDG. (authors)

  13. Radiation dose reduction with dictionary learning based processing for head CT

    International Nuclear Information System (INIS)

    Chen, Yang; Shi, Luyao; Hu, Yining; Luo, Limin; Yang, Jiang; Yin, Xindao; Coatrieux, Jean-Louis

    2014-01-01

    In CT, ionizing radiation exposure from the scan has attracted much concern from patients and doctors. This work is aimed at improving head CT images from low-dose scans by using a fast Dictionary learning (DL) based post-processing. Both Low-dose CT (LDCT) and Standard-dose CT (SDCT) nonenhanced head images were acquired in head examination from a multi-detector row Siemens Somatom Sensation 16 CT scanner. One hundred patients were involved in the experiments. Two groups of LDCT images were acquired with 50 % (LDCT50 %) and 25 % (LDCT25 %) tube current setting in SDCT. To give quantitative evaluation, Signal to noise ratio (SNR) and Contrast to noise ratio (CNR) were computed from the Hounsfield unit (HU) measurements of GM, WM and CSF tissues. A blinded qualitative analysis was also performed to assess the processed LDCT datasets. Fifty and seventy five percent dose reductions are obtained for the two LDCT groups (LDCT50 %, 1.15 ± 0.1 mSv; LDCT25 %, 0.58 ± 0.1 mSv; SDCT, 2.32 ± 0.1 mSv; P < 0.001). Significant SNR increase over the original LDCT images is observed in the processed LDCT images for all the GM, WM and CSF tissues. Significant GM–WM CNR enhancement is noted in the DL processed LDCT images. Higher SNR and CNR than the reference SDCT images can even be achieved in the processed LDCT50 % and LDCT25 % images. Blinded qualitative review validates the perceptual improvements brought by the proposed approach. Compared to the original LDCT images, the application of DL processing in head CT is associated with a significant improvement of image quality.

  14. rCBF in radiation necrosis as measured by xenon-enhanced CT

    International Nuclear Information System (INIS)

    Nakamura, Osamu; Nomura, Kazuhiro; Segawa, Hiromu; Nakagomi, Tadayoshi; Tanaka, Hideki; Yoshimasu, Norio; Takakura, Kintomo.

    1986-01-01

    We experienced a case of radiation necrosis in which the necrosis occurred two and a half years after radiation therapy against craniopharyngioma. In this case, we evaluated the regional cerebral blood flow (rCBF) by means of the Xe-enhanced CT method and studied the change in rCBF in comparison with the rCBF pattern of brain tumors or cerebral infarctions. In general, rCBF decreased in accordance with the low-density area in a conventional CT scan. The decrease in rCBF was most significant in the white matter, but the rCBF in the thinned cortex was also lowered. On the contrary, that of the basal ganglia was almost completely preserved. The rCBF pattern was different from those of brain tumors or diffuse cerebral infarction caused by the occlusion of the main arteries and was thought to be characteristic of radiation necrosis. Differential diagnosis between radiation necrosis and the recurrence of brain tumor has been thought to be difficult, but with this rCBF analysis the possibility of differential diagnosis between the two lesions was clearly indicated. (author)

  15. Application of low-dose radiation protocols in survey CT scans

    International Nuclear Information System (INIS)

    Fu Qiang; Liu Ting; Lu Tao; Xu Ke; Zhang Lin

    2009-01-01

    Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for chest, 80 kV, 10 mA for abdomen and 100 kV, 10 mA for lumbar. The values of ESD for phantom scan in default and optimized protocols were 0.38 mGy/0.16 mGy in head, 0.30 mGy/0.20 mGy in chest, 0.74 mGy/0.30 mGy in abdomen and 0.81 mGy/0.44 mGy in lumbar, respectively. Compared with default protocols, the optimized protocols reduced the radiation doses 59%, 33%, 59% and 46% in head, chest, abdomen and lumbar. When tube position changed from 0 degree to 180 degree, the ESD were 0.24 mGy/0.20 mGy for chest; 0.37 mGy/0.30 mGy for abdomen, and the radiation doses were reduced 20% and 17%. Conclusion: A certain amount of image noise is increased in low-dose protocols, but image quality is still acceptable without problem in CT localization. The reduction of radiation dose and the radiation harm to patients are the superiority. (authors)

  16. Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw [Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Liu, Shu-Hsin [Department of Nuclear Medicine, Buddhist Tzu-Chi General Hospital, 970, Hualien, Taiwan and Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Mok, Greta S. P. [Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, 112, Taipei, Taiwan (China)

    2014-09-15

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

  17. Clinical indications and radiation doses to the conceptus associated with CT imaging in pregnancy: a retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Woussen, S.; Vanbeckevoort, D.; Bosmans, H.; Oyen, R. [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Lopez-Rendon, X.; Zanca, F. [University Hospitals Leuven, Department of Imaging and Pathology, Leuven (Belgium)

    2016-04-15

    To perform an internal audit at a university hospital with the aim of evaluating the number, clinical indication and operating procedure of computed tomography (CT) performed on pregnant patients and of estimating the radiation doses to the conceptus. A retrospective review was conducted of all CT examinations performed in a single centre on pregnant patients between January 2008 and July 2013. The radiation doses to the conceptus were estimated. The results were compared with published data. The number of CT examinations during pregnancy increased from 3-4 per year in 2008-2011 to 11 per year in 2012. The mean estimated conceptus radiation dose was considered negligible for CT of the head and cervical spine, being less than 0.01 mGy, and for CT of the chest, less than 0.1 mGy. The estimated conceptus radiation dose from abdominopelvic CT was on average 28.7 mGy (range 6.7-60.5 mGy). The number of CT scans of pregnant patients increased threefold during the last few years. Most clinical indications and doses were in line with good clinical practice and literature; only in two cases the dose to the conceptus was higher than 50 mGy. (orig.)

  18. Analytical equations for CT dose profiles derived using a scatter kernel of Monte Carlo parentage with broad applicability to CT dosimetry problems

    International Nuclear Information System (INIS)

    Dixon, Robert L.; Boone, John M.

    2011-01-01

    Purpose: Knowledge of the complete axial dose profile f(z), including its long scatter tails, provides the most complete (and flexible) description of the accumulated dose in CT scanning. The CTDI paradigm (including CTDI vol ) requires shift-invariance along z (identical dose profiles spaced at equal intervals), and is therefore inapplicable to many of the new and complex shift-variant scan protocols, e.g., high dose perfusion studies using variable (or zero) pitch. In this work, a convolution-based beam model developed by Dixon et al.[Med. Phys. 32, 3712-3728, (2005)] updated with a scatter LSF kernel (or DSF) derived from a Monte Carlo simulation by Boone [Med. Phys. 36, 4547-4554 (2009)] is used to create an analytical equation for the axial dose profile f(z) in a cylindrical phantom. Using f(z), equations are derived which provide the analytical description of conventional (axial and helical) dose, demonstrating its physical underpinnings; and likewise for the peak axial dose f(0) appropriate to stationary phantom cone beam CT, (SCBCT). The methodology can also be applied to dose calculations in shift-variant scan protocols. This paper is an extension of our recent work Dixon and Boone [Med. Phys. 37, 2703-2718 (2010)], which dealt only with the properties of the peak dose f(0), its relationship to CTDI, and its appropriateness to SCBCT. Methods: The experimental beam profile data f(z) of Mori et al.[Med. Phys. 32, 1061-1069 (2005)] from a 256 channel prototype cone beam scanner for beam widths (apertures) ranging from a = 28 to 138 mm are used to corroborate the theoretical axial profiles in a 32 cm PMMA body phantom. Results: The theoretical functions f(z) closely-matched the central axis experimental profile data 11 for all apertures (a = 28 -138 mm). Integration of f(z) likewise yields analytical equations for all the (CTDI-based) dosimetric quantities of conventional CT (including CTDI L itself) in addition to the peak dose f(0) relevant to SCBCT

  19. Value of CT scanning in radiation therapy treatment planning: a prospective study

    International Nuclear Information System (INIS)

    Goitein, M.; Wittenberg, J.; Mendiondo, M.; Doucette, J.; Friedberg, C.; Ferrucci, J.; Gunderson, L.; Linggood, R.; Shipley, W.U.; Fineberg, H.V.

    1979-01-01

    We report the results of a prospective study in which we assessed the value of computed tomography (CT) scanning in planning radiation therapy for 77 patients. First, conventional studies were performed, treatment fields were designed and simulated and, where appropriate, computer generated treatment plans drawn up. Then a CT scan was performed to delineate the location of the tumor and adjacent uninvolved tissues. The treatment goals and plans were reevaluated and changed when necessary. Forty of the 77 patients (52%) had their treatment changed as a result of the CT scan. Of these, four (5%) had a change of treatment modality. Thirty-two patients (42%) had changes in the radiotherapy technique because of inadequate tumor coverage (in 24 patients (31%) part of the tumor was outside one or more of the fields and in the other 8 patients (10%) the tumor coverage was marginal). Field changes resulting only from considerations of normal tissue coverage were made for 4 of these patients (5%). In total, normal tissue coverage was affected in 36 patients (47%). When the significance of these changes was evaluated, CT scanning was judged to be of major value for 28 of the 77 patients (36%) and of minor value in a further 12 patients

  20. AN EVALUATION OF THE BASIC CHARACTERISTICS OF A PLASTIC SCINTILLATING FIBRE DETECTOR IN CT RADIATION FIELDS.

    Science.gov (United States)

    Terasaki, Kento; Fujibuchi, Toshioh; Toyoda, Takatoshi; Yoshida, Yutaka; Akasaka, Tsutomu; Nohtomi, Akihiro; Morishita, Junji

    2016-12-01

    The ionisation chamber for computed tomography (CT) is an instrument that is most commonly used to measure the computed tomography dose index. However, it has been reported that the 10 cm effective detection length of the ionisation chamber is insufficient due to the extent of the dose distribution outside the chamber. The purpose of this study was to estimate the basic characteristics of a plastic scintillating fibre (PSF) detector with a long detection length of 50 cm in CT radiation fields. The authors investigated position dependence using diagnostic X-ray equipment and dependencies for energy, dose rate and slice thickness using an X-ray CT system. The PSF detector outputs piled up at a count rate of 10 000 counts ms -1 in dose rate dependence study. With calibration, this detector may be useful as a CT dosemeter with a long detection length except for the measurement at high dose rate. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Development of a Radiation Dose Reporting Software for X-ray Computed Tomography (CT)

    Science.gov (United States)

    Ding, Aiping

    X-ray computed tomography (CT) has experienced tremendous technological advances in recent years and has established itself as one of the most popular diagnostic imaging tools. While CT imaging clearly plays an invaluable role in modern medicine, its rapid adoption has resulted in a dramatic increase in the average medical radiation exposure to the worldwide and United States populations. Existing software tools for CT dose estimation and reporting are mostly based on patient phantoms that contain overly simplified anatomies insufficient in meeting the current and future needs. This dissertation describes the development of an easy-to-use software platform, “VirtualDose”, as a service to estimate and report the organ dose and effective dose values for patients undergoing the CT examinations. “VirtualDose” incorporates advanced models for the adult male and female, pregnant women, and children. To cover a large portion of the ignored obese patients that frequents the radiology clinics, a new set of obese male and female phantoms are also developed and applied to study the effects of the fat tissues on the CT radiation dose. Multi-detector CT scanners (MDCT) and clinical protocols, as well as the most recent effective dose algorithms from the International Commission on Radiological Protection (ICRP) Publication 103 are adopted in “VirtualDose” to keep pace with the MDCT development and regulatory requirements. A new MDCT scanner model with both body and head bowtie filter is developed to cover both the head and body scanning modes. This model was validated through the clinical measurements. A comprehensive slice-by-slice database is established by deriving the data from a larger number of single axial scans simulated on the patient phantoms using different CT bowtie filters, beam thicknesses, and different tube voltages in the Monte Carlo N-Particle Extended (MCNPX) code. When compared to the existing CT dose software packages, organ dose data in this

  2. Radiation exposure to the staff working in PET/CT and Cyclotron Facility

    International Nuclear Information System (INIS)

    Ivanova, S.D.

    2016-01-01

    Positron Emission Tomography (PET) has been available in number of centers for more than 25 years, but its use was not wide spread until 10 years ago. In Bulgarian PET/CT was installed for the first time in 2009 and the dose on demand cyclotron also for the first time – in 2013 in Nuclear Medicine Department in University Hospital St. Marina in Varna, Bulgaria. Responsibility of every radiation protection officer is to educate the stuff how to protect their selves from radioactive exposure and to observe and calculate the dose to the people and the stuff. The purpose of this paper is to show how big the doses of the stuff working in Nuclear Medicine Center including PET/CT and Cyclotron facilities situated in University Hospital St. Marina in Varna, Bulgaria are. The Department is working now with about 15 patients every day. The dose rates measured with personal TLD’s and personal dose rate meters for the last 5 years for the stuff are under 3 mSv. As the average dose is under 1 mSv, and the doses over 1mSv are only for nurses who injected the FDG. Keywords: radiation exposure, effective dose, PET/CT, Cyclotron, FDGbf

  3. Radiation dose of CT coronary angiography in clinical practice: Objective evaluation of strategies for dose optimization

    International Nuclear Information System (INIS)

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-01-01

    Background: CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. Objectives: To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Methods: Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Results: Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (−47%; 95% CI, −44% to −50%), prospective gating (−35%; 95% CI, −29% to −40%) and ECG controlled tube current modulation (−23%; 95% CI, −9% to −34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Conclusion: Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality.

  4. Gene expression profiles in cervical cancer with radiation therapy alone and chemo-radiation therapy

    International Nuclear Information System (INIS)

    Lee, Kyu Chan; Kim, Joo Young; Hwang, You Jin; Kim, Meyoung Kon; Choi, Myung Sun; Kim, Chul Young

    2003-01-01

    To analyze the gene expression profiles of uterine cervical cancer, and its variation after radiation therapy, with or without concurrent chemotherapy, using a cDNA microarray. Sixteen patients, 8 with squamous cell carcinomas of the uterine cervix, who were treated with radiation alone, and the other 8 treated with concurrent chemo-radiation, were included in the study. Before the starting of the treatment, tumor biopsies were carried out, and the second time biopsies were performed after a radiation dose of 16.2-27 Gy. Three normal cervix tissues were used as a control group. The microarray experiments were performed with 5 groups of the total RNAs extracted individually and then admixed as control, pre-radiation therapy alone, during-radiation therapy alone, pre-chemoradiation therapy, and during chemoradiation therapy. The 33P-labeled cDNAs were synthesized from the total RNAs of each group, by reverse transcription, and then they were hybridized to the cDNA microarray membrane. The gene expression of each microarrays was captured by the intensity of each spot produced by the radioactive isotopes. The pixels per spot were counted with an Arrayguage, and were exported to Microsoft Excel. The data were normalized by the Z transformation, and the comparisons were performed on the Z-ratio values calculated. The expressions of 15 genes, including integrin linked kinase (ILK), CDC28 protein kinase 2, Spry 2, and ERK 3, were increased with the Z-ratio values of over 2.0 for the cervix cancer tissues compared to those for the normal controls. Those genes were involved in cell growth and proliferation, cell cycle control, or signal transduction. The expressions of the other 6 genes, including G protein coupled receptor kinase 6, were decreased with the Z-ratio values of below -2.0. After the radiation therapy, most of the genes, with a previously increase expressions, represented the decreased expression profiles, and the genes, with the Z-ratio values of over 2.0, were

  5. A preliminary study to detect CT radiation doses by using the γH2AX focus formation assay

    International Nuclear Information System (INIS)

    Zhang Bo; Gong Jianping; Zhang Wei; Yu Zeyang; Zhou Liying; Zhang Hong; Fu Jinxiang

    2010-01-01

    To prospectively determine if γH2AX (phosphorylated form of H2AX histone variant)-based visualization and quantification of DNA damage induced in peripheral blood mononuclear cells (PBMCs) can be used to estimate the radiation dose received after multi-detector computed tomography (CT) by the in vitro study, comprehend the correlation between the dose and the induced γH2AX foci, and explore its prospect. The result showed that, DNA damage first presented as γH2AX foci after CT, which can be detected by fluorescence microscope. The γH2AX focus yields linearly depend on the radiation dose after CT. γH2AX focus yield in blood cells may be a useful quantitative biomarker of human radiation exposure by CT scans. (authors)

  6. Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method

    Energy Technology Data Exchange (ETDEWEB)

    Larson, David B. [Stanford University School of Medicine, Department of Radiology, Stanford, CA (United States)

    2014-10-15

    The principle of ALARA (dose as low as reasonably achievable) calls for dose optimization rather than dose reduction, per se. Optimization of CT radiation dose is accomplished by producing images of acceptable diagnostic image quality using the lowest dose method available. Because it is image quality that constrains the dose, CT dose optimization is primarily a problem of image quality rather than radiation dose. Therefore, the primary focus in CT radiation dose optimization should be on image quality. However, no reliable direct measure of image quality has been developed for routine clinical practice. Until such measures become available, size-specific dose estimates (SSDE) can be used as a reasonable image-quality estimate. The SSDE method of radiation dose optimization for CT abdomen and pelvis consists of plotting SSDE for a sample of examinations as a function of patient size, establishing an SSDE threshold curve based on radiologists' assessment of image quality, and modifying protocols to consistently produce doses that are slightly above the threshold SSDE curve. Challenges in operationalizing CT radiation dose optimization include data gathering and monitoring, managing the complexities of the numerous protocols, scanners and operators, and understanding the relationship of the automated tube current modulation (ATCM) parameters to image quality. Because CT manufacturers currently maintain their ATCM algorithms as secret for proprietary reasons, prospective modeling of SSDE for patient populations is not possible without reverse engineering the ATCM algorithm and, hence, optimization by this method requires a trial-and-error approach. (orig.)

  7. TH-CD-207B-05: Measurement of CT Bow-Tie Profiles Using a Linear Array Detector

    Energy Technology Data Exchange (ETDEWEB)

    Yang, K; Li, X; Liu, B [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: To accurately measure CT bow-tie profiles from various manufacturers and to provide non-proprietary information for CT system modeling. Methods: A GOS-based linear detector (0.8 mm per pixel and 51.2 cm in length) with a fast data sampling speed (0.24 ms/sample) was used to measure the relative profiles of bow-tie filters from a collection of eight CT scanners by three different vendors, GE (LS Xtra, LS VCT, Discovery HD750), Siemens (Sensation 64, Edge, Flash, Force), and Philips (iBrilliance 256). The linear detector was first calibrated for its energy response within typical CT beam quality ranges and compared with an ion chamber and analytical modeling (SPECTRA and TASMIP). A geometrical calibration process was developed to determine key parameters including the distance from the focal spot to the linear detector, the angular increment of the gantry at each data sampling, the location of the central x-ray on the linear detector, and the angular response of the detector pixel. Measurements were performed under axial-scan modes for most representative bow-tie filters and kV selections from each scanner. Bow-tie profiles were determined by re-binning the measured rotational data with an angular accuracy of 0.1 degree using the calibrated geometrical parameters. Results: The linear detector demonstrated an energy response as a solid state detector, which is close to the CT imaging detector. The geometrical calibration was proven to be sufficiently accurate (< 1mm in error for distances >550 mm) and the bow-tie profiles measured from rotational mode matched closely to those from the gantry-stationary mode. Accurate profiles were determined for a total of 21 bow-tie filters and 83 filter/kV combinations from the abovementioned scanner models. Conclusion: A new improved approach of CT bow-tie measurement was proposed and accurate bow-tie profiles were provided for a broad list of CT scanner models.

  8. Evaluating applicability of metal artifact reduction algorithm for head and neck radiation treatment planning CT

    International Nuclear Information System (INIS)

    Son, Sang Jun; Park, Jang Pil; Kim, Min Jeong; Yoo, Suk Hyun

    2014-01-01

    The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head and neck radiation treatment planning CT with metal artifact created by dental implant. All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120 kVp, 2 mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). In cases of head and neck phantom, the difference of dose distribution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area

  9. X-ray phase-contrast CT imaging of the acupoints based on synchrotron radiation

    International Nuclear Information System (INIS)

    Chenglin, Liu; Xiaohua, Wang; Hua, Xu; Fang, Liu; Ruishan, Dang; Dongming, Zhang; Xinyi, Zhang; Honglan, Xie; Tiqiao, Xiao

    2014-01-01

    In this paper, the morphology of the acupuncture point (abbreviated as acupoint hereafter) or tissue where there were no acupoints in the fractional rabbit hind limb was studied by in-line phase contrast CT imaging (PCI-CT) methods based on synchrotron radiation. The density of micro-vessels was calculated for tissues with acupoints or without acupoints. Differences between acupoints area and non-acupoint areas determined by the density of the micro-vessels propose a strong evidence of the existence of acupoints. Our results showed that there were two significantly higher densities of the micro-vessels, where two acupoints were located, respectively. In addition, there were large numbers of involutedly microvascular structure in the acupoint areas. Nevertheless, in non-acupoints area, the microvascular structure was relatively simple and flat

  10. X-ray phase-contrast CT imaging of the acupoints based on synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Chenglin, Liu, E-mail: lclyctc@163.com [Physics Department of Yancheng Teachers’ College, Yancheng 224051 (China); Xiaohua, Wang; Hua, Xu [Physics Department of Yancheng Teachers’ College, Yancheng 224051 (China); Fang, Liu; Ruishan, Dang [Anatomy Department of Second Military Medical University, Shanghai 200433 (China); Dongming, Zhang; Xinyi, Zhang [Synchrotron Radiation Research Center of Fudan University, Shanghai 200433 (China); Honglan, Xie; Tiqiao, Xiao [Shanghai Synchrotron Radiation Facility of Shanghai Institute of Applied Physics, CAS, Shanghai 201800 (China)

    2014-10-15

    In this paper, the morphology of the acupuncture point (abbreviated as acupoint hereafter) or tissue where there were no acupoints in the fractional rabbit hind limb was studied by in-line phase contrast CT imaging (PCI-CT) methods based on synchrotron radiation. The density of micro-vessels was calculated for tissues with acupoints or without acupoints. Differences between acupoints area and non-acupoint areas determined by the density of the micro-vessels propose a strong evidence of the existence of acupoints. Our results showed that there were two significantly higher densities of the micro-vessels, where two acupoints were located, respectively. In addition, there were large numbers of involutedly microvascular structure in the acupoint areas. Nevertheless, in non-acupoints area, the microvascular structure was relatively simple and flat.

  11. Anatomical database generation for radiation transport modeling from computed tomography (CT) scan data

    International Nuclear Information System (INIS)

    Margle, S.M.; Tinnel, E.P.; Till, L.E.; Eckerman, K.F.; Durfee, R.C.

    1989-01-01

    Geometric models of the anatomy are used routinely in calculations of the radiation dose in organs and tissues of the body. Development of such models has been hampered by lack of detailed anatomical information on children, and models themselves have been limited to quadratic conic sections. This summary reviews the development of an image processing workstation used to extract anatomical information from routine diagnostic CT procedure. A standard IBM PC/AT microcomputer has been augmented with an automatically loading 9-track magnetic tape drive, an 8-bit 1024 x 1024 pixel graphics adapter/monitor/film recording package, a mouse/trackball assembly, dual 20 MB removable cartridge media, a 72 MB disk drive, and a printer. Software utilized by the workstation includes a Geographic Information System (modified for manipulation of CT images), CAD software, imaging software, and various modules to ease data transfer among the software packages. 5 refs., 3 figs

  12. Radiation Exposure to Staff in Intensive Care Unit with Portable CT Scanner

    Directory of Open Access Journals (Sweden)

    Zhichao Xie

    2016-01-01

    Full Text Available Background. Bedside radiological procedures pose a risk of radiation exposure to ICU staff. The perception of risk may increase the degree of caution among the health care staff and raise new barriers preventing patients from obtaining prompt care. Objective. The aim of this study was to estimate the annual cumulative radiation dose to individual ICU staff. Methods. In this prospective study, forty subjects were required to wear thermoluminescent dosimeter badges during their working hours. The badges were analyzed to determine the exposure after 3 months. Results. A total of 802 radiological procedures were completed at bedside during the study period. The estimated annual dosage to doctors and nurses on average was 0.99 mSv and 0.88 mSv (p<0.001, respectively. Residents were subjected to the highest radiation exposure (1.04 mSv per year, p=0.002. The radiation dose was correlated with day shift working hours (r=0.426; p=0.006 and length of service (r=-0.403; p<0.01. Conclusions. With standard precautions, bedside radiological procedures—including portable CT scans—do not expose ICU staff to high dose of ionizing radiation. The level of radiation exposure is related to the daytime working hours and length of service.

  13. Calculation of shielding and radiation doses for PET/CT nuclear medicine facility

    International Nuclear Information System (INIS)

    Mollah, A.S.; Muraduzzaman, S.M.

    2011-01-01

    Positron emission tomography (PET) is a new modality that is gaining use in nuclear medicine. The use of PET and computed tomography (CT) has grown dramatically. Because of the high energy of the annihilation radiation (511 keV), shielding requirements are an important consideration in the design of a PET or PET/CT imaging facility. The goal of nuclear medicine and PET facility shielding design is to keep doses to workers and the public as low as reasonably achievable (ALARA). Design involves: 1. Calculation of doses to occupants of the facility and adjacent regions based on projected layouts, protocols and workflows, and 2. Reduction of doses to ALARA through adjustment of the aforementioned parameters. The radiological evaluation of a PET/CT facility consists of the assessment of the annual effective dose both to workers occupationally exposed, and to members of the public. This assessment takes into account the radionuclides involved, the facility features, the working procedures, the expected number of patients per year, and so on. The objective of the study was to evaluate shielding requirements for a PET/CT to be installed in the department of nuclear medicine of Bangladesh Atomic Energy Commission (BAEC). Minimizing shielding would result in a possible reduction of structural as well as financial burden. Formulas and attenuation coefficients following the basic AAPM guidelines were used to calculate un-attenuated radiation through shielding materials. Doses to all points on the floor plan are calculated based primarily on the AAPM guidelines and include consideration of broad beam attenuation and radionuclide energy and decay. The analysis presented is useful for both, facility designers and regulators. (author)

  14. Radiation Safety Management Guidelines for PET-CT: Focus on Behavior and Environment

    International Nuclear Information System (INIS)

    Jung, Jin Wook; Han, Eun Ok

    2011-01-01

    Our purpose is to specify behavior and environmental factors aimed at reducing the exposed dosage caused by PET-CT and to develop radiation safety management guidelines adequate for domestic circumstances. We have used a multistep-multimethod as the methodological approach to design and to carry out the research both in quality and quantity, including an analysis on previous studies, professional consultations and a survey. The survey includes responses from 139 practitioners in charged of 109 PET-CTs installed throughout Korea(reported by the Korean Society of Nuclear Medicine, 2010). The research use 156 questions using Cronbach's α (alpha) coefficients which were: 0.818 for 'the necessity of setting and installing the radiation protective environment'; 0.916 for 'the necessity of radiation protection', 'setting and installing the radiation protective environment'; and 0.885 for 'radiation protection'. The check list, derived from the radiation safety management guidelines focused on behavior and environment, was composed of 20 items for the radiation protective environment: including 5 items for the patient; 4 items for the guardian; 3 items for the radiologist; and 8 items applied to everyone involved; for a total of 26 items for the radiation protective behavior including: 12 items for the patient; 1 item for the guardian, 7 items for the radiologist; and 6 items applied to everyone involved. The specific check list is shown in (Table 5-6). Since our country has no safety management guidelines of its own to reduce the exposed dosage caused by PET-CTs, we believe the guidelines developed through this study means great deal to the field as it is not only appropriate for domestic circumstances, but also contains specific check lists for each target who may be exposed to radiation in regards to behavior and environment.

  15. Understanding the scatter radiation distribution during C-arm CT examination. A body phantom study

    International Nuclear Information System (INIS)

    Norimasa, Toshiyo; Kakimi, Akihiko; Takao, Yoshinori; Sasaki, Shohei; Katayama, Yutaka; Himoto, Daisuke; Izuta, Shinichiro; Ichida, Takao

    2016-01-01

    The purpose of this study was to understand the scatter radiation distribution during C-arm CT examination in the interventional radiography (IVR) room to show the escaped area and the radiation protective method. The C-arm rotates 200deg in 5 s. The tube voltage was 90 kV, and the entrance dose to the detector was 0.36 μGy/frame during C-arm CT examination. The scattered doses were measured each 50 cm from the isocenter like a grid pattern. The heights of the measurement were 50, 100, and 150 cm from the floor. The maximum scattered doses were 38.23 ± 0.60 μGy at 50 cm, 43.86 ± 20 μGy at 100 cm, and 25.78 ± 0.37 μGy at 150 cm. The scatter radiation distribution at 100 cm was the highest scattered dose. The operator should protect their reproductive gland, thyroid, and lens. The scattered dose was low behind the C-arm body and the bed, so they will be able to become the escaped area for staff. (author)

  16. Presentation of the project EPI-CT: A cohort study of children with substantial diagnostic medical exposure to ionizing radiation

    International Nuclear Information System (INIS)

    Bosch de Basea, M.; Cardis, E.; Vrijheid, M.

    2011-01-01

    Ionizing radiation for diagnostic purposes are an indispensable tool in modern medicine. The increasing use of computed tomography (CT) in children and adolescents is of concern both from the point of view of radio-protection and public health. children are more sensitive to the carcinogenic effects of ionizing radiation than adults. Children also have a higher life expectancy to show any detrimental effect. Furthermore, because of their smaller mass, CT scans in children receiving higher doses of radiation in specific organs in adults.

  17. Ultra-low-dose CT imaging of the thorax: decreasing the radiation dose by one order of magnitude

    International Nuclear Information System (INIS)

    Lambert, Lukas; Banerjee, Rohan; Votruba, Jiri; El-Lababidi, Nabil; Zeman, Jiri

    2016-01-01

    Computed tomography (CT) is an indispensable tool for imaging of the thorax and there is virtually no alternative without associated radiation burden. The authors demonstrate ultra-low-dose CT of the thorax in three interesting cases. In an 18-y-old girl with rheumatoid arthritis, CT of the thorax identified alveolitis in the posterior costophrenic angles (radiation dose = 0.2 mSv). Its resolution was demonstrated on a follow-up scan (4.2 mSv) performed elsewhere. In an 11-y-old girl, CT (0.1 mSv) showed changes of the right collar bone consistent with chronic recurrent multifocal osteomyelitis. CT (0.1 mSv) of a 9-y-old girl with mucopolysaccharidosis revealed altogether three hamartomas, peribronchial infiltrate, and spine deformity. In some indications, the radiation dose from CT of the thorax can approach that of several plain radiographs. This may help the pediatrician in deciding whether 'gentle' ultra-low-dose CT instead of observation or follow-up radiographs will alleviate the uncertainty of the diagnosis with little harm to the child. (author)

  18. Two examples of indication specific radiation dose calculations in dental CBCT and Multidetector CT scanners.

    Science.gov (United States)

    Stratis, Andreas; Zhang, Guozhi; Lopez-Rendon, Xochitl; Politis, Constantinus; Hermans, Robert; Jacobs, Reinhilde; Bogaerts, Ria; Shaheen, Eman; Bosmans, Hilde

    2017-09-01

    To calculate organ doses and estimate the effective dose for justification purposes in patients undergoing orthognathic treatment planning purposes and temporal bone imaging in dental cone beam CT (CBCT) and Multidetector CT (MDCT) scanners. The radiation dose to the ICRP reference male voxel phantom was calculated for dedicated orthognathic treatment planning acquisitions via Monte Carlo simulations in two dental CBCT scanners, Promax 3D Max (Planmeca, FI) and NewTom VGi evo (QR s.r.l, IT) and in Somatom Definition Flash (Siemens, DE) MDCT scanner. For temporal bone imaging, radiation doses were calculated via MC simulations for a CBCT protocol in NewTom 5G (QR s.r.l, IT) and with the use of a software tool (CT-expo) for Somatom Force (Siemens, DE). All procedures had been optimized at the acceptance tests of the devices. For orthognathic protocols, dental CBCT scanners deliver lower doses compared to MDCT scanners. The estimated effective dose (ED) was 0.32mSv for a normal resolution operation mode in Promax 3D Max, 0.27mSv in VGi-evo and 1.18mSv in the Somatom Definition Flash. For temporal bone protocols, the Somatom Force resulted in an estimated ED of 0.28mSv while for NewTom 5G the ED was 0.31 and 0.22mSv for monolateral and bilateral imaging respectively. Two clinical exams which are carried out with both a CBCT or a MDCT scanner were compared in terms of radiation dose. Dental CBCT scanners deliver lower doses for orthognathic patients whereas for temporal bone procedures the doses were similar. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Diagnostic accuracy at several reduced radiation dose levels for CT imaging in the diagnosis of appendicitis

    Science.gov (United States)

    Zhang, Di; Khatonabadi, Maryam; Kim, Hyun; Jude, Matilda; Zaragoza, Edward; Lee, Margaret; Patel, Maitraya; Poon, Cheryce; Douek, Michael; Andrews-Tang, Denise; Doepke, Laura; McNitt-Gray, Shawn; Cagnon, Chris; DeMarco, John; McNitt-Gray, Michael

    2012-03-01

    Purpose: While several studies have investigated the tradeoffs between radiation dose and image quality (noise) in CT imaging, the purpose of this study was to take this analysis a step further by investigating the tradeoffs between patient radiation dose (including organ dose) and diagnostic accuracy in diagnosis of appendicitis using CT. Methods: This study was IRB approved and utilized data from 20 patients who underwent clinical CT exams for indications of appendicitis. Medical record review established true diagnosis of appendicitis, with 10 positives and 10 negatives. A validated software tool used raw projection data from each scan to create simulated images at lower dose levels (70%, 50%, 30%, 20% of original). An observer study was performed with 6 radiologists reviewing each case at each dose level in random order over several sessions. Readers assessed image quality and provided confidence in their diagnosis of appendicitis, each on a 5 point scale. Liver doses at each case and each dose level were estimated using Monte Carlo simulation based methods. Results: Overall diagnostic accuracy varies across dose levels: 92%, 93%, 91%, 90% and 90% across the 100%, 70%, 50%, 30% and 20% dose levels respectively. And it is 93%, 95%, 88%, 90% and 90% across the 13.5-22mGy, 9.6-13.5mGy, 6.4-9.6mGy, 4-6.4mGy, and 2-4mGy liver dose ranges respectively. Only 4 out of 600 observations were rated "unacceptable" for image quality. Conclusion: The results from this pilot study indicate that the diagnostic accuracy does not change dramatically even at significantly reduced radiation dose.

  20. Assess results of PET/CT in cancer diagnosis, follow up treatment and simulation for radiation therapy

    International Nuclear Information System (INIS)

    Mai Trong Khoa; Tran Dinh Ha; Tran Hai Binh

    2015-01-01

    PET/CT (Positron Emission Computed Tomography) has been studied and established as routine at the Nuclear Medicine and Oncology Center, Bach Mai hospital. From 8/2009 to 5/2015, 6223 patients have been undergone PET/CT scan. Among them, diagnostic and simulation PET/CT scan for cancer patients accounted to 5833 (93.8%). Researches about value of PET/CT for most common cancers have been done. Results: PET/CT can help the primary tumor diagnosis, metastases detection, staging, simulation for radiation therapy, response to treatment assessment, and relapses after treatment identification. Percentage accordance between PET / CT and histopathology was 96% (esophagus cancer), 94.7% (lung cancer). Average maxSUV value of primary tumor of the esophagus cancer, colorectal cancer, nasopharynx cancer, lung cancer, and NHL respectively 9.50, 9.78, 11.08, 9.17, 10.21. MaxSUV value increased with histological grade and tumor size. After undergone PET / CT, stage of disease changed in 28% esophagus cancer; 22.7% colorectal cancer; stage of disease increased in 23.5% of NHL, 32.0% of lung cancer, and 25.0% of nasopharynx cancer. PET / CT simulation for radiation therapy target volume reduced in 28% of nasopharynx cancer, which helped the radioactive dose concentrate exactly in the target lesions, minimize effect to healthy tissues, improved the effectiveness of treatment and reduced complications. (author)

  1. Improvement of internal tumor volumes of non-small cell lung cancer patients for radiation treatment planning using interpolated average CT in PET/CT.

    Directory of Open Access Journals (Sweden)

    Yao-Ching Wang

    Full Text Available Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT or positron emission tomography (PET images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpolated average CT (IACT as attenuation correction (AC to diminish the occurrence of this scenario. Thirteen non-small cell lung cancer patients were recruited for the present comparison study. Each patient had full-inspiration, full-expiration CT images and free breathing PET images by an integrated PET/CT scan. IACT for AC in PET(IACT was used to reduce the PET/CT misalignment. The standardized uptake value (SUV correction with a low radiation dose was applied, and its tumor volume delineation was compared to those from HCT/PET(HCT. The misalignment between the PET(IACT and IACT was reduced when compared to the difference between PET(HCT and HCT. The range of tumor motion was from 4 to 17 mm in the patient cohort. For HCT and PET(HCT, correction was from 72% to 91%, while for IACT and PET(IACT, correction was from 73% to 93% (*p<0.0001. The maximum and minimum differences in SUVmax were 0.18% and 27.27% for PET(HCT and PET(IACT, respectively. The largest percentage differences in the tumor volumes between HCT/PET and IACT/PET were observed in tumors located in the lowest lobe of the lung. Internal tumor volume defined by functional information using IACT/PET(IACT fusion images for lung cancer would reduce the inaccuracy of tumor delineation in radiation therapy planning.

  2. Radiation Dose Reduction of Chest CT with Iterative Reconstruction in Image Space - Part I: Studies on Image Quality Using Dual Source CT

    International Nuclear Information System (INIS)

    Hwang, Hye Jeon; Seo, Joon Beom; Lee, Jin Seong; Song, Jae Woo; Lee, Hyun Joo; Lim, Chae Hun; Kim, Song Soo

    2012-01-01

    To determine whether the image quality (IQ) is improved with iterative reconstruction in image space (IRIS), and whether IRIS can be used for radiation reduction in chest CT. Standard dose chest CT (SDCT) in 50 patients and low dose chest CT (LDCT) in another 50 patients were performed, using a dual-source CT, with 120 kVp and same reference mAs (50 mAs for SDCT and 25 mAs for LDCT) employed to both tubes by modifying a dual-energy scan mode. Full-dose data were obtained by combining the data from both tubes and half-dose data were separated from a single tube. These were reconstructed by using a filtered back projection (FBP) and IRIS: full-dose FBP (F-FBP); full-dose IRIS (F-IRIS); half-dose FBP (H-FBP) and half-dose IRIS (H-IRIS). Objective noise was measured. The subjective IQ was evaluated by radiologists for the followings: noise, contrast and sharpness of mediastinum and lung. Objective noise was significantly lower in H-IRIS than in F-FBP (p < 0.01). In both SDCT and LDCT, the IQ scores were highest in F-IRIS, followed by F-FBP, H-IRIS and H-FBP, except those for sharpness of mediastinum, which tended to be higher in FBP. When comparing CT images between the same dose and different reconstruction (F-IRIS/F-FBP and H-IRIS/H-FBP) algorithms, scores tended to be higher in IRIS than in FBP, being more distinct in half-dose images. However, despite the use of IRIS, the scores were lower in H-IRIS than in F-FBP. IRIS generally helps improve the IQ, being more distinct at the reduced radiation. However, reduced radiation by half results in IQ decrease even when using IRIS in chest CT.

  3. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroto; Okada, Masahiro; Hyodo, Tomoko; Hidaka, Syojiro; Kagawa, Yuki; Matsuki, Mitsuru; Tsurusaki, Masakatsu; Murakami, Takamichi, E-mail: murakami@med.kindai.ac.jp

    2014-04-15

    Purpose: To investigate whether low-dose dynamic CT of the liver with iterative reconstruction can reduce both the radiation dose and the amount of contrast medium. Materials and methods: This study was approved by our institutional review board. 113 patients were randomly assigned to one of two groups. Group A/group B (fifty-eight/fifty-five patients) underwent liver dynamic CT at 120/100 kV, with 0/40% adaptive statistical iterative reconstruction (ASIR), with a contrast dose of 600/480 mg I/kg, respectively. Radiation exposure was estimated based on the manufacturer's phantom data. The enhancement value of the hepatic parenchyma, vessels and the tumor-to-liver contrast of hepatocellular carcinomas (HCCs) were compared between two groups. Two readers independently assessed the CT images of the hepatic parenchyma and HCCs. Results: The mean CT dose indices: 6.38/4.04 mGy, the dose-length products: 194.54/124.57 mGy cm, for group A/group B. The mean enhancement value of the hepatic parenchyma and the tumor-to-liver contrast of HCCs with diameters greater than 1 cm in the post-contrast all phases did not differ significantly between two groups (P > 0.05). The enhancement values of vessels in group B were significantly higher than that in group A in the delayed phases (P < 0.05). Two reader's confidence levels for the hepatic parenchyma in the delayed phases and HCCs did not differ significantly between the groups (P > 0.05). Conclusions: Low-dose dynamic CT with ASIR can reduce both the radiation dose and the amount of contrast medium without image quality degradation, compared to conventional dynamic CT without ASIR.

  4. Effects of ray profile modeling on resolution recovery in clinical CT

    International Nuclear Information System (INIS)

    Hofmann, Christian; Knaup, Michael; Kachelrieß, Marc

    2014-01-01

    Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. However, among vendors and researchers, there is no consensus of how to best achieve these goals. The authors are focusing on the aspect of geometric ray profile modeling, which is realized by some algorithms, while others model the ray as a straight line. The authors incorporate ray-modeling (RM) in nonregularized iterative reconstruction. That means, instead of using one simple single needle beam to represent the x-ray, the authors evaluate the double integral of attenuation path length over the finite source distribution and the finite detector element size in the numerical forward projection. Our investigations aim at analyzing the resolution recovery (RR) effects of RM. Resolution recovery means that frequencies can be recovered beyond the resolution limit of the imaging system. In order to evaluate, whether clinical CT images can benefit from modeling the geometrical properties of each x-ray, the authors performed a 2D simulation study of a clinical CT fan-beam geometry that includes the precise modeling of these geometrical properties. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and a Forbild thorax phantom with circular resolution patterns representing calcifications in the heart region are simulated. An FBP reconstruction with a Ram–Lak kernel is used as a reference reconstruction. The FBP is compared to iterative reconstruction techniques with and without RM: An ordered subsets convex (OSC) algorithm without any RM (OSC), an OSC where the forward projection is modeled concerning the finite focal spot and detector size (OSC-RM) and an OSC with RM and with a matched forward and backprojection pair (OSC-T-RM, T for transpose). In all cases, noise was matched to

  5. The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine. Pt. 2. Benefits versus risk of CT

    Energy Technology Data Exchange (ETDEWEB)

    Westra, Sjirk J. [Massachusetts General Hospital, Division of Pediatric Radiology, Boston, MA (United States)

    2014-10-15

    In order to personalize the communication of the CT risk, we need to describe the risk in the context of the clinical benefit of CT, which will generally be much higher, provided a CT scan has a well-established clinical indication. However as pediatric radiologists we should be careful not to overstate the benefit of CT, being aware that medico-legal pressures and the realities of health care economics have led to overutilization of the technology. And even though we should not use previously accumulated radiation dose to a child as an argument against conducting a clinically indicated scan (the ''sunk-cost'' bias), we should consider patients' radiation history in the diagnostic decision process. As a contribution to future public health, it makes more sense to look for non-radiating alternatives to CT in the much larger group of basically healthy children who are receiving occasional scans for widely prevalent conditions such as appendicitis and trauma than to attempt lowering CT use in the smaller group of patients with chronic conditions with a limited life expectancy. When communicating the CT risk with individual patients and their parents, we should acknowledge and address their concerns within the framework of informed decision-making. When appropriate, we may express the individual radiation risk, based on estimates of summated absorbed organ dose, as an order of magnitude rather than as an absolute number, and compare this with the much larger natural cancer incidence over a child's lifetime, and with other risks in medicine and daily life. We should anticipate that many patients cannot make informed decisions on their own in this complex matter, and we should offer our guidance while maintaining respect for patient autonomy. Proper documentation of the informed decision process is important for future reference. In concert with our referring physicians, pediatric radiologists are well-equipped to tackle the complexities

  6. The communication of the radiation risk from CT in relation to its clinical benefit in the era of personalized medicine. Pt. 2. Benefits versus risk of CT

    International Nuclear Information System (INIS)

    Westra, Sjirk J.

    2014-01-01

    In order to personalize the communication of the CT risk, we need to describe the risk in the context of the clinical benefit of CT, which will generally be much higher, provided a CT scan has a well-established clinical indication. However as pediatric radiologists we should be careful not to overstate the benefit of CT, being aware that medico-legal pressures and the realities of health care economics have led to overutilization of the technology. And even though we should not use previously accumulated radiation dose to a child as an argument against conducting a clinically indicated scan (the ''sunk-cost'' bias), we should consider patients' radiation history in the diagnostic decision process. As a contribution to future public health, it makes more sense to look for non-radiating alternatives to CT in the much larger group of basically healthy children who are receiving occasional scans for widely prevalent conditions such as appendicitis and trauma than to attempt lowering CT use in the smaller group of patients with chronic conditions with a limited life expectancy. When communicating the CT risk with individual patients and their parents, we should acknowledge and address their concerns within the framework of informed decision-making. When appropriate, we may express the individual radiation risk, based on estimates of summated absorbed organ dose, as an order of magnitude rather than as an absolute number, and compare this with the much larger natural cancer incidence over a child's lifetime, and with other risks in medicine and daily life. We should anticipate that many patients cannot make informed decisions on their own in this complex matter, and we should offer our guidance while maintaining respect for patient autonomy. Proper documentation of the informed decision process is important for future reference. In concert with our referring physicians, pediatric radiologists are well-equipped to tackle the complexities associated with the communication

  7. 3D automatic exposure control for 64-detector row CT: Radiation dose reduction in chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Keiko, E-mail: palm_kei@yahoo.co.jp [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Ohno, Yoshiharu; Koyama, Hisanobu; Kono, Atsushi [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Inokawa, Hiroyasu [Toshiba Medical Systems, Ohtawara, Tochigi (Japan); Onishi, Yumiko [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Nogami, Munenobu [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Division of Image-Based Medicine, Institute of Biomedical Research and Innovation, Kobe, Hyogo (Japan); Takenaka, Daisuke [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan); Araki, Tsutomu [Department of Radiology, Yamanashi University, Shimokato, Yamanashi (Japan); Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo (Japan)

    2011-03-15

    Purpose: The purpose of this study was to determine the utility of three-dimensional (3D) automatic exposure control (AEC) for low-dose CT examination in a chest phantom study. Materials and methods: A chest CT phantom including simulated focal ground-glass opacities (GGOs) and nodules was scanned with a 64-detector row CT with and without AEC. Performance of 3D AEC included changing targeted standard deviations (SDs) of image noise from scout view. To determine the appropriate targeted SD number for identification, the capability of overall identification with the CT protocol adapted to each of the targeted SDs was compared with that obtained with CT without AEC by means of receiver operating characteristic analysis. Results: When targeted SD values equal to or higher than 250 were used, areas under the curve (Azs) of nodule identification with CT protocol using AEC were significantly smaller than that for CT protocol without AEC (p < 0.05). When targeted SD numbers at equal to or more than 180 were adapted, Azs of CT protocol with AEC had significantly smaller than that without AEC (p < 0.05). Conclusion: This phantom study shows 3D AEC is useful for low-dose lung CT examination, and can reduce the radiation dose while maintaining good identification capability and good image quality.

  8. Localization of the prostatic apex using CT for radiation treatment planning

    International Nuclear Information System (INIS)

    Li Xiaomei; Gao Xianshu; Guo Xuemei; Li Yagang; Wang Xiaoying

    2011-01-01

    Objective: In this retrospective study, we analyzed the magnetic resonance imaging (MRI) and computed tomography (CT) scans of patients with prostate cancer to investigate the relationship between the apex of prostate and the anatomic structures visible in CT, and to provide evidence for localizing the prostatic apex in radiation treatment planning. Methods: MRI and CT scans from 108 patients with prostate cancer were analyzed to measure the distance between the prostatic apex and the bottom of ischial tuberosities, the bottom of obturator foramen, the bottom of pubic symphysis and the bulb of the penis. The volume of prostate was calculated and the relationship between the size of the prostate and the localization of the prostatic apex was analyzed. Results: The prostatic apex is located 13.1 mm ± 3.3 mm superior to the bulb of the penis, 11.0 mm ± 5.4 mm superior to the bottom of obturator foramen, 31.3 mm ± 5.5 mm superior to the bottom of ischial tuberosities, and 7.1 mm ± 4.7 mm superior to the bottom of obturator foramen. There was no correlation between the size of prostate and the localization of the prostatic apex (R =0.07, -0.33, all P > 0.05). Conclusions: Ninety-five percent of patients had a prostatic apex that is above the bulb of the penis 6 mm, and 100% of patients had a prostatic apex that is above the bottom of obturator foramen. (authors)

  9. Application of high resolution synchrotron micro-CT radiation in dental implant osseointegration.

    Science.gov (United States)

    Neldam, Camilla Albeck; Lauridsen, Torsten; Rack, Alexander; Lefolii, Tore Tranberg; Jørgensen, Niklas Rye; Feidenhans'l, Robert; Pinholt, Else Marie

    2015-06-01

    The purpose of this study was to describe a refined method using high-resolution synchrotron radiation microtomography (SRmicro-CT) to evaluate osseointegration and peri-implant bone volume fraction after titanium dental implant insertion. SRmicro-CT is considered gold standard evaluating bone microarchitecture. Its high resolution, high contrast, and excellent high signal-to-noise-ratio all contribute to the highest spatial resolutions achievable today. Using SRmicro-CT at a voxel size of 5 μm in an experimental goat mandible model, the peri-implant bone volume fraction was found to quickly increase to 50% as the radial distance from the implant surface increased, and levelled out to approximately 80% at a distance of 400 μm. This method has been successful in depicting the bone and cavities in three dimensions thereby enabling us to give a more precise answer to the fraction of the bone-to-implant contact compared to previous methods. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Integrated analysis of dynamic FET PET/CT parameters, histology, and methylation profiling of 44 gliomas.

    Science.gov (United States)

    Röhrich, Manuel; Huang, Kristin; Schrimpf, Daniel; Albert, Nathalie L; Hielscher, Thomas; von Deimling, Andreas; Schüller, Ulrich; Dimitrakopoulou-Strauss, Antonia; Haberkorn, Uwe

    2018-05-07

    Dynamic 18 F-FET PET/CT is a powerful tool for the diagnosis of gliomas. 18 F-FET PET time-activity curves (TAC) allow differentiation between histological low-grade gliomas (LGG) and high-grade gliomas (HGG). Molecular methods such as epigenetic profiling are of rising importance for glioma grading and subclassification. Here, we analysed dynamic 18 F-FET PET data, and the histological and epigenetic features of 44 gliomas. Dynamic 18 F-FET PET was performed in 44 patients with newly diagnosed, untreated glioma: 10 WHO grade II glioma, 13 WHO grade III glioma and 21 glioblastoma (GBM). All patients underwent stereotactic biopsy or tumour resection after 18 F-FET PET imaging. As well as histological analysis of tissue samples, DNA was subjected to epigenetic analysis using the Illumina 850 K methylation array. TACs, standardized uptake values corrected for background uptake in healthy tissue (SUVmax/BG), time to peak (TTP) and kinetic modelling parameters were correlated with histological diagnoses and with epigenetic signatures. Multivariate analyses were performed to evaluate the diagnostic accuracy of 18 F-FET PET in relation to the tumour groups identified by histological and methylation-based analysis. Epigenetic profiling led to substantial tumour reclassification, with six grade II/III gliomas reclassified as GBM. Overlap of HGG-typical TACs and LGG-typical TACs was dramatically reduced when tumours were clustered on the basis of their methylation profile. SUVmax/BG values of GBM were higher than those of LGGs following both histological diagnosis and methylation-based diagnosis. The differences in TTP between GBMs and grade II/III gliomas were greater following methylation-based diagnosis than following histological diagnosis. Kinetic modeling showed that relative K1 and fractal dimension (FD) values significantly differed in histology- and methylation-based GBM and grade II/III glioma between those diagnosed histologically and those diagnosed by

  11. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    International Nuclear Information System (INIS)

    Efstathopoulos, E P; Kelekis, N L; Pantos, I; Brountzos, E; Argentos, S; Grebac, J; Ziaka, D; Seimenis, I; Katritsis, D G

    2009-01-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  12. Ambient radiation monitoring at a PET/CT imaging center within a nuclear medicine department

    International Nuclear Information System (INIS)

    Lai, Y.C.; Chen, Y.W.; Chuang, Y.W.

    2006-01-01

    Full text of publication follows: Potential environmental dose rates in a patient waiting room at the PET/CT Imaging Center within our Nuclear Medicine Department (N.M.D.) are evaluated by both of the computer modeling method and real-time monitoring in practical settings. The maximum dose rate is directly read from a peak dose-rate frozen-up, digital gamma G-M survey meter. The design basis of our PET/CT Imaging Center facility has assumed a maximum total of five 18 FDG-patients presented at any given time either in an Am or a Pm session according to two separated drug batch delivering runs. Due to the relatively high gamma energy of 511 keV emitted by the F- 18 labeled compound, we have remodeled our facility with a 0.5-cm thick Pb wall and larger space separations between rooms that include a PET/CT scan room, two separated 18 FDG i.v. injection rooms, and a delayed-phase patient waiting room. Patient could normally complete two separate PET/CT scan runs, if a delayed-phase scan is needed, within three hours time frame from an initial dose of 370 MBq (10 mCi) that has a physical half-live of 110 minutes for an F-18 labeled compound. When all the needed scans are finished, the patient is released from our PET/CT Imaging Center that has to follow the radiation safety guideline of less than 50 mSv/hr (5 m R/hr) at one meter distance. During typical operation, each drug i.v. injection room or the scan room is restricted to one patient access only. As a worst case scenario, the maximum ambient dose rate may only occur when two or more delayed phase patients would stay in the PET/CT waiting room that is excluded for other non-PET patient use. Theoretically using a computer discrete-ordinate integrating methods, dose rates at one meter distance from a mid-point geometry, based on a simulated 10 mCi F-18 point, line or volumetric source (assuming 170 cm in height and 20 cm in radius of homogeneous water media), can also be calculated to give values of 5.71, 4.73 and 3

  13. Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction.

    Science.gov (United States)

    Fahimian, Benjamin P; Zhao, Yunzhe; Huang, Zhifeng; Fung, Russell; Mao, Yu; Zhu, Chun; Khatonabadi, Maryam; DeMarco, John J; Osher, Stanley J; McNitt-Gray, Michael F; Miao, Jianwei

    2013-03-01

    A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest scanner flux setting of 39 m

  14. Radiation dose reduction in medical x-ray CT via Fourier-based iterative reconstruction

    International Nuclear Information System (INIS)

    Fahimian, Benjamin P.; Zhao Yunzhe; Huang Zhifeng; Fung, Russell; Zhu Chun; Miao Jianwei; Mao Yu; Khatonabadi, Maryam; DeMarco, John J.; McNitt-Gray, Michael F.; Osher, Stanley J.

    2013-01-01

    Purpose: A Fourier-based iterative reconstruction technique, termed Equally Sloped Tomography (EST), is developed in conjunction with advanced mathematical regularization to investigate radiation dose reduction in x-ray CT. The method is experimentally implemented on fan-beam CT and evaluated as a function of imaging dose on a series of image quality phantoms and anonymous pediatric patient data sets. Numerical simulation experiments are also performed to explore the extension of EST to helical cone-beam geometry. Methods: EST is a Fourier based iterative algorithm, which iterates back and forth between real and Fourier space utilizing the algebraically exact pseudopolar fast Fourier transform (PPFFT). In each iteration, physical constraints and mathematical regularization are applied in real space, while the measured data are enforced in Fourier space. The algorithm is automatically terminated when a proposed termination criterion is met. Experimentally, fan-beam projections were acquired by the Siemens z-flying focal spot technology, and subsequently interleaved and rebinned to a pseudopolar grid. Image quality phantoms were scanned at systematically varied mAs settings, reconstructed by EST and conventional reconstruction methods such as filtered back projection (FBP), and quantified using metrics including resolution, signal-to-noise ratios (SNRs), and contrast-to-noise ratios (CNRs). Pediatric data sets were reconstructed at their original acquisition settings and additionally simulated to lower dose settings for comparison and evaluation of the potential for radiation dose reduction. Numerical experiments were conducted to quantify EST and other iterative methods in terms of image quality and computation time. The extension of EST to helical cone-beam CT was implemented by using the advanced single-slice rebinning (ASSR) method. Results: Based on the phantom and pediatric patient fan-beam CT data, it is demonstrated that EST reconstructions with the lowest

  15. Does iterative reconstruction lower CT radiation dose: evaluation of 15,000 examinations.

    Directory of Open Access Journals (Sweden)

    Peter B Noël

    Full Text Available PURPOSE: Evaluation of 15,000 computed tomography (CT examinations to investigate if iterative reconstruction (IR reduces sustainably radiation exposure. METHOD AND MATERIALS: Information from 15,000 CT examinations was collected, including all aspects of the exams such as scan parameter, patient information, and reconstruction instructions. The examinations were acquired between January 2010 and December 2012, while after 15 months a first generation IR algorithm was installed. To collect the necessary information from PACS, RIS, MPPS and structured reports a Dose Monitoring System was developed. To harvest all possible information an optical character recognition system was integrated, for example to collect information from the screenshot CT-dose report. The tool transfers all data to a database for further processing such as the calculation of effective dose and organ doses. To evaluate if IR provides a sustainable dose reduction, the effective dose values were statistically analyzed with respect to protocol type, diagnostic indication, and patient population. RESULTS: IR has the potential to reduce radiation dose significantly. Before clinical introduction of IR the average effective dose was 10.1±7.8mSv and with IR 8.9±7.1mSv (p*=0.01. Especially in CTA, with the possibility to use kV reduction protocols, such as in aortic CTAs (before IR: average14.2±7.8mSv; median11.4mSv /with IR:average9.9±7.4mSv; median7.4mSv, or pulmonary CTAs (before IR: average9.7±6.2mSV; median7.7mSv /with IR: average6.4±4.7mSv; median4.8mSv the dose reduction effect is significant(p*=0.01. On the contrary for unenhanced low-dose scans of the cranial (for example sinuses the reduction is not significant (before IR:average6.6±5.8mSv; median3.9mSv/with IR:average6.0±3.1mSV; median3.2mSv. CONCLUSION: The dose aspect remains a priority in CT research. Iterative reconstruction algorithms reduce sustainably and significantly radiation dose in the clinical routine

  16. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    OpenAIRE

    Erdi Yusuf E; Casciotta Kevin A; Dauer Lawrence T; Rothenberg Lawrence N

    2007-01-01

    Abstract Background It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to...

  17. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  18. Patient-specific radiation dose and cancer risk for pediatric chest CT.

    Science.gov (United States)

    Li, Xiang; Samei, Ehsan; Segars, W Paul; Sturgeon, Gregory M; Colsher, James G; Frush, Donald P

    2011-06-01

    To estimate patient-specific radiation dose and cancer risk for pediatric chest computed tomography (CT) and to evaluate factors affecting dose and risk, including patient size, patient age, and scanning parameters. The institutional review board approved this study and waived informed consent. This study was HIPAA compliant. The study included 30 patients (0-16 years old), for whom full-body computer models were recently created from clinical CT data. A validated Monte Carlo program was used to estimate organ dose from eight chest protocols, representing clinically relevant combinations of bow tie filter, collimation, pitch, and tube potential. Organ dose was used to calculate effective dose and risk index (an index of total cancer incidence risk). The dose and risk estimates before and after normalization by volume-weighted CT dose index (CTDI(vol)) or dose-length product (DLP) were correlated with patient size and age. The effect of each scanning parameter was studied. Organ dose normalized by tube current-time product or CTDI(vol) decreased exponentially with increasing average chest diameter. Effective dose normalized by tube current-time product or DLP decreased exponentially with increasing chest diameter. Chest diameter was a stronger predictor of dose than weight and total scan length. Risk index normalized by tube current-time product or DLP decreased exponentially with both chest diameter and age. When normalized by DLP, effective dose and risk index were independent of collimation, pitch, and tube potential (chest CT protocols. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101900/-/DC1. RSNA, 2011

  19. Continued Development Of An Inexpensive Simulator Based CT Scanner For Radiation Therapy Treatment Planning

    Science.gov (United States)

    Peschmann, K. R.; Parker, D. L.; Smith, V.

    1982-11-01

    An abundant number of different CT scanner models has been developed in the past ten years, meeting increasing standards of performance. From the beginning they remained a comparatively expensive piece of equipment. This is due not only to their technical complexity but is also due to the difficulties involved in assessing "true" specifications (avoiding "overde-sign"). Our aim has been to provide, for Radiation Therapy Treatment Planning, a low cost CT scanner system featuring large freedom in patient positioning. We have taken advantage of the concurrent tremendously increased amount of knowledge and experience in the technical area of CT1 . By way of extensive computer simulations we gained confidence that an inexpensive C-arm simulator gantry and a simple one phase-two pulse generator in connection with a standard x-ray tube could be used, without sacrificing image quality. These components have been complemented by a commercial high precision shaft encoder, a simple and effective fan beam collimator, a high precision, high efficiency, luminescence crystal-silicon photodiode detector with 256 channels, low noise electronic preamplifier and sampling filter stages, a simplified data aquisition system furnished by Toshiba/ Analogic and an LSI 11/23 microcomputer plus data storage disk as well as various smaller interfaces linking the electrical components. The quality of CT scan pictures of phantoms,performed by the end of last year confirmed that this simple approach is working well. As a next step we intend to upgrade this system with an array processor in order to shorten recon-struction time to one minute per slice. We estimate that the system including this processor could be manufactured for a selling price of $210,000.

  20. TU-CD-BRB-01: Normal Lung CT Texture Features Improve Predictive Models for Radiation Pneumonitis

    International Nuclear Information System (INIS)

    Krafft, S; Briere, T; Court, L; Martel, M

    2015-01-01

    Purpose: Existing normal tissue complication probability (NTCP) models for radiation pneumonitis (RP) traditionally rely on dosimetric and clinical data but are limited in terms of performance and generalizability. Extraction of pre-treatment image features provides a potential new category of data that can improve NTCP models for RP. We consider quantitative measures of total lung CT intensity and texture in a framework for prediction of RP. Methods: Available clinical and dosimetric data was collected for 198 NSCLC patients treated with definitive radiotherapy. Intensity- and texture-based image features were extracted from the T50 phase of the 4D-CT acquired for treatment planning. A total of 3888 features (15 clinical, 175 dosimetric, and 3698 image features) were gathered and considered candidate predictors for modeling of RP grade≥3. A baseline logistic regression model with mean lung dose (MLD) was first considered. Additionally, a least absolute shrinkage and selection operator (LASSO) logistic regression was applied to the set of clinical and dosimetric features, and subsequently to the full set of clinical, dosimetric, and image features. Model performance was assessed by comparing area under the curve (AUC). Results: A simple logistic fit of MLD was an inadequate model of the data (AUC∼0.5). Including clinical and dosimetric parameters within the framework of the LASSO resulted in improved performance (AUC=0.648). Analysis of the full cohort of clinical, dosimetric, and image features provided further and significant improvement in model performance (AUC=0.727). Conclusions: To achieve significant gains in predictive modeling of RP, new categories of data should be considered in addition to clinical and dosimetric features. We have successfully incorporated CT image features into a framework for modeling RP and have demonstrated improved predictive performance. Validation and further investigation of CT image features in the context of RP NTCP

  1. Robust inverse-consistent affine CT-MR registration in MRI-assisted and MRI-alone prostate radiation therapy.

    Science.gov (United States)

    Rivest-Hénault, David; Dowson, Nicholas; Greer, Peter B; Fripp, Jurgen; Dowling, Jason A

    2015-07-01

    CT-MR registration is a critical component of many radiation oncology protocols. In prostate external beam radiation therapy, it allows the propagation of MR-derived contours to reference CT images at the planning stage, and it enables dose mapping during dosimetry studies. The use of carefully registered CT-MR atlases allows the estimation of patient specific electron density maps from MRI scans, enabling MRI-alone radiation therapy planning and treatment adaptation. In all cases, the precision and accuracy achieved by registration influences the quality of the entire process. Most current registration algorithms do not robustly generalize and lack inverse-consistency, increasing the risk of human error and acting as a source of bias in studies where information is propagated in a particular direction, e.g. CT to MR or vice versa. In MRI-based treatment planning where both CT and MR scans serve as spatial references, inverse-consistency is critical, if under-acknowledged. A robust, inverse-consistent, rigid/affine registration algorithm that is well suited to CT-MR alignment in prostate radiation therapy is presented. The presented method is based on a robust block-matching optimization process that utilises a half-way space definition to maintain inverse-consistency. Inverse-consistency substantially reduces the influence of the order of input images, simplifying analysis, and increasing robustness. An open source implementation is available online at http://aehrc.github.io/Mirorr/. Experimental results on a challenging 35 CT-MR pelvis dataset demonstrate that the proposed method is more accurate than other popular registration packages and is at least as accurate as the state of the art, while being more robust and having an order of magnitude higher inverse-consistency than competing approaches. The presented results demonstrate that the proposed registration algorithm is readily applicable to prostate radiation therapy planning. Copyright © 2015. Published by

  2. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    International Nuclear Information System (INIS)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-01-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176 Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176 Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  3. PET/CT alignment calibration with a non-radioactive phantom and the intrinsic 176Lu radiation of PET detector

    Science.gov (United States)

    Wei, Qingyang; Ma, Tianyu; Wang, Shi; Liu, Yaqiang; Gu, Yu; Dai, Tiantian

    2016-11-01

    Positron emission tomography/computed tomography (PET/CT) is an important tool for clinical studies and pre-clinical researches which provides both functional and anatomical images. To achieve high quality co-registered PET/CT images, alignment calibration of PET and CT scanner is a critical procedure. The existing methods reported use positron source phantoms imaged both by PET and CT scanner and then derive the transformation matrix from the reconstructed images of the two modalities. In this paper, a novel PET/CT alignment calibration method with a non-radioactive phantom and the intrinsic 176Lu radiation of the PET detector was developed. Firstly, a multi-tungsten-alloy-sphere phantom without positron source was designed and imaged by CT and the PET scanner using intrinsic 176Lu radiation included in LYSO. Secondly, the centroids of the spheres were derived and matched by an automatic program. Lastly, the rotation matrix and the translation vector were calculated by least-square fitting of the centroid data. The proposed method was employed in an animal PET/CT system (InliView-3000) developed in our lab. Experimental results showed that the proposed method achieves high accuracy and is feasible to replace the conventional positron source based methods.

  4. Radiation dose of digital tomosynthesis for sinonasal examination: comparison with multi-detector CT.

    Science.gov (United States)

    Machida, Haruhiko; Yuhara, Toshiyuki; Tamura, Mieko; Numano, Tomokazu; Abe, Shinji; Sabol, John M; Suzuki, Shigeru; Ueno, Eiko

    2012-06-01

    Using an anthropomorphic phantom, we have investigated the feasibility of digital tomosynthesis (DT) of flat-panel detector (FPD) radiography to reduce radiation dose for sinonasal examination compared to multi-detector computed tomography (MDCT). A female Rando phantom was scanned covering frontal to maxillary sinus using the clinically routine protocol by both 64-detector CT (120 kV, 200 mAs, and 1.375-pitch) and DT radiography (80 kV, 1.0 mAs per projection, 60 projections, 40° sweep, and posterior-anterior projections). Glass dosimeters were used to measure the radiation dose to internal organs including the thyroid gland, brain, submandibular gland, and the surface dose at various sites including the eyes during those scans. We compared the radiation dose to those anatomies between both modalities. In DT radiography, the doses of the thyroid gland, brain, submandibular gland, skin, and eyes were 230 ± 90 μGy, 1770 ± 560 μGy, 1400 ± 80 μGy, 1160 ± 2100 μGy, and 112 ± 6 μGy, respectively. These doses were reduced to approximately 1/5, 1/8, 1/12, 1/17, and 1/290 of the respective MDCT dose. For sinonasal examinations, DT radiography enables dramatic reduction in radiation exposure and dose to the head and neck region, particularly to the lens of the eye. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Aristophanous, Michalis, E-mail: maristophanous@lroc.harvard.edu [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center and Harvard Medical School, Boston, MA (United States); Berbeco, Ross I.; Killoran, Joseph H. [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center and Harvard Medical School, Boston, MA (United States); Yap, Jeffrey T. [Department of Radiology, Dana-Farber Cancer Institute and Harvard Medical School, Boston, MA (United States); Sher, David J.; Allen, Aaron M.; Larson, Elysia; Chen, Aileen B. [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center and Harvard Medical School, Boston, MA (United States)

    2012-01-01

    Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

  6. Comparison of CT and integrated PET-CT based radiation therapy planning in patients with malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Pehlivan, Berrin; Topkan, Erkan; Onal, Cem; Nursal, Gul Nihal; Yuksel, Oznur; Dolek, Yemliha; Yavuz, Melek Nur; Yavuz, Ali Aydin

    2009-01-01

    When combined with adequate tumoricidal doses, accurate target volume delineation remains to be the one of the most important predictive factors for radiotherapy (RT) success in locally advanced or medically inoperable malignant pleural mesothelioma (MPM) patients. Recently, 18-fluorodeoxyglucose positron emission tomography (PET) has demonstrated significant improvements in diagnosis and accurate staging of MPM. However, role of additional PET data has not been studied in RT planning (RTP) of patients with inoperable MPM or in those who refuse surgery. Therefore, we planned to compare CT with co-registered PET-CT as the basis for delineating target volumes in these patients group. Retrospectively, the CT and co-registered PET-CT data of 13 patients with histologically proven MPM were utilized to delineate target volumes separately. For each patient, target volumes (gross tumor volume [GTV], clinical target volume [CTV], and planning target volume [PTV]) were defined using the CT and PET-CT fusion data sets. The PTV was measured in two ways: PTV1 was CTV plus a 1-cm margin, and PTV2 was GTV plus a 1-cm margin. We analyzed differences in target volumes. In 12 of 13 patients, compared to CT-based delineation, PET-CT-based delineation resulted in a statistically significant decrease in the mean GTV, CTV, PTV1, and PTV2. In these 12 patients, mean GTV decreased by 47.1% ± 28.4%, mean CTV decreased by 38.7% ± 24.7%, mean PTV1 decreased by 31.1% ± 23.1%, and mean PTV2 decreased by 40.0% ± 24.0%. In 4 of 13 patients, hilar lymph nodes were identified by PET-CT that was not identified by CT alone, changing the nodal status of tumor staging in those patients. This study demonstrated the usefulness of PET-CT-based target volume delineation in patients with MPM. Co-registration of PET and CT information reduces the likelihood of geographic misses, and additionally, significant reductions observed in target volumes may potentially allow escalation of RT dose beyond

  7. Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Ming; Chu, Sung-Yu; Hsu, Ming-Yi [Chang Gung University, Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital Linkou, College of Medicine, Taoyuan (China); Liao, Ying-Lan [National Tsing Hua University, Department of Biomedical Engineering and Environmental Sciences, Hsinchu (China); Tsai, Hui-Yu [Chang Gung University, Department of Medical Imaging and Radiological Sciences, College of Medicine, Taoyuan (China); Chang Gung University, Healthy Aging Research Center, Taoyuan (China); Chang Gung University, Department of Medical Imaging and Radiological Sciences, Taoyuan (China)

    2014-02-15

    To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDI{sub vol}), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. The low-tube-voltage protocol showed 23-31 % higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48 % reduction in CTDI{sub vol} and an 80 % increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. (orig.)

  8. Radiation-induced refraction artifacts in the optical CT readout of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Campbell, Warren G.; Jirasek, Andrew; Wells, Derek M.

    2014-01-01

    Purpose: The objective of this work is to demonstrate imaging artifacts that can occur during the optical computed tomography (CT) scanning of polymer gel dosimeters due to radiation-induced refractive index (RI) changes in polyacrylamide gels. Methods: A 1 L cylindrical polyacrylamide gel dosimeter was irradiated with 3 × 3 cm 2 square beams of 6 MV photons. A prototype fan-beam optical CT scanner was used to image the dosimeter. Investigative optical CT scans were performed to examine two types of rayline bending: (i) bending within the plane of the fan-beam and (ii) bending out the plane of the fan-beam. To address structured errors, an iterative Savitzky–Golay (ISG) filtering routine was designed to filter 2D projections in sinogram space. For comparison, 2D projections were alternatively filtered using an adaptive-mean (AM) filter. Results: In-plane rayline bending was most notably observed in optical CT projections where rays of the fan-beam confronted a sustained dose gradient that was perpendicular to their trajectory but within the fan-beam plane. These errors caused distinct streaking artifacts in image reconstructions due to the refraction of higher intensity rays toward more opaque regions of the dosimeter. Out-of-plane rayline bending was observed in slices of the dosimeter that featured dose gradients perpendicular to the plane of the fan-beam. These errors caused widespread, severe overestimations of dose in image reconstructions due to the higher-than-actual opacity that is perceived by the scanner when light is bent off of the detector array. The ISG filtering routine outperformed AM filtering for both in-plane and out-of-plane rayline errors caused by radiation-induced RI changes. For in-plane rayline errors, streaks in an irradiated region (>7 Gy) were as high as 49% for unfiltered data, 14% for AM, and 6% for ISG. For out-of-plane rayline errors, overestimations of dose in a low-dose region (∼50 cGy) were as high as 13 Gy for unfiltered

  9. High-resolution three-dimensional visualization of the rat spinal cord microvasculature by synchrotron radiation micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Jianzhong; Cao, Yong; Wu, Tianding; Li, Dongzhe [Department of Spine Surgery, Xiangya Hospital, Central South University, Changsha 410008 (China); Lu, Hongbin, E-mail: hongbinlu@hotmail.com [Department of Sports Medicine, Research Centre of Sports Medicine, Xiangya Hospital, Central South University, Changsha 410008 (China)

    2014-10-15

    Purpose: Understanding the three-dimensional (3D) morphology of the spinal cord microvasculature has been limited by the lack of an effective high-resolution imaging technique. In this study, synchrotron radiation microcomputed tomography (SRµCT), a novel imaging technique based on absorption imaging, was evaluated with regard to the detection of the 3D morphology of the rat spinal cord microvasculature. Methods: Ten Sprague-Dawley rats were used in this ex vivo study. After contrast agent perfusion, their spinal cords were isolated and scanned using conventional x-rays, conventional micro-CT (CµCT), and SRµCT. Results: Based on contrast agent perfusion, the microvasculature of the rat spinal cord was clearly visualized for the first time ex vivo in 3D by means of SRµCT scanning. Compared to conventional imaging techniques, SRµCT achieved higher resolution 3D vascular imaging, with the smallest vessel that could be distinguished approximately 7.4 μm in diameter. Additionally, a 3D pseudocolored image of the spinal cord microvasculature was generated in a single session of SRµCT imaging, which was conducive to detailed observation of the vessel morphology. Conclusions: The results of this study indicated that SRµCT scanning could provide higher resolution images of the vascular network of the spinal cord. This modality also has the potential to serve as a powerful imaging tool for the investigation of morphology changes in the 3D angioarchitecture of the neurovasculature in preclinical research.

  10. Posttreatment assessment of response using FDG-PET/CT for patients treated with definitive radiation therapy for head and neck cancers

    International Nuclear Information System (INIS)

    Andrade, Regiane S.; Heron, Dwight E.; Degirmenci, Berna; Filho, Pedro A.A.; Branstetter, Barton F.; Seethala, Raja R.; Ferris, Robert L.; Avril, Norbert

    2006-01-01

    Purpose: The goal of this study was to evaluate coregistered [ 18 F] fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) for the detection of persistent disease after definitive radiation therapy in head and neck cancer. Methods and Materials: Posttreatment FDG-PET/CT was performed in 28 patients on average 8 weeks (range, 4 to 15.7 weeks) after completing definitive radiation therapy. FDG-PET/CT was visually analyzed for the entire patient group and at two time points (4-8 and >8 weeks) after treatment. The contrast-enhanced CT portion of PET/CT was separately analyzed blinded to the results of coregistered FDG-PET/CT and classified as negative or positive for residual locoregional disease. Pathologic findings and clinical follow-up served as the reference standard. Results: Follow-up data were available for all 28 patients (median, 17.6 months). Regarding the detection of residual disease, the overall sensitivity and specificity of FDG-PET/CT was 76.9% and 93.3%, respectively, compared with 92.3% and 46.7% for contrast-enhanced CT. The accuracy of FDG-PET/CT was 85.7%, compared with 67.9% for CT alone. All false-negative (n = 3) and false-positive (n = 1) FDG-PET/CT results occurred between 4 and 8 weeks after treatment. At 8 weeks or later after treatment, the specificity of CT was 28%, compared with 100% for FDG-PET/CT. Conclusions: The metabolic-anatomic information from coregistered FDG-PET/CT provided the most accurate assessment for treatment response when performed later than 8 weeks after the conclusion of radiation therapy. FDG-PET/CT excelled by a higher specificity and overall diagnostic performance than CT imaging alone. These results support a potential clinical role of FDG-PET/CT in the early assessment of therapy response after definitive radiation therapy

  11. Radiation dose reduction on multidetector abdominal CT using adaptive statistical iterative reconstruction technique in children

    International Nuclear Information System (INIS)

    Zhang Qifeng; Peng Yun; Duan Xiaomin; Sun Jihang; Yu Tong; Han Zhonglong

    2013-01-01

    Objective: To investigate the feasibility to reduce radiation doses on pediatric multidetector abdominal CT using the adaptive statistical iterative reconstruction technique (ASIR) associated with automated tube current modulation technique (ATCM). Methods: Thirty patients underwent abdominal CT with ATCM and the follow-up scan with ATCM cooperated with 40% ASIR. ATCM was used with age dependent noise index (NI) settings: NI = 9 for 0-5 year old and NI = 11 for > 5 years old for simple ATCM group, NI = 11 for 0-5 year old and NI = 15 for > 5 years old for ATCM cooperated with 40% ASIR group (AISR group). Two radiologists independently evaluated images for diagnostic quality and image noise with subjectively image quality score and image noise score using a 5-point scale. Interobserver agreement was assessed by Kappa test. The volume CT dose indexes (CTDIvol) for the two groups were recorded. Statistical significance for the CTDIvol value was analyzed by pair-sample t test. Results: The average CTDIvol for the ASIR group was (1.38 ± 0.64) mGy, about 60% lower than (3.56 ± 1.23) mGy for the simple ATCM group, and the CTDIvol of two groups had statistically significant differences. (t = 33.483, P < 0.05). The subjective image quality scores for the simple ATCM group were 4.43 ± 0.57 and 4.37 ±0.61, Kappa = 0.878, P < 0.01 (ASIR group: 4.70 ± 0.47 and 4.60 ± 0.50, Kappa = 0.783, P < 0.01), by two observers. The image noise score for the simple ATCM group were 4.03 ±0.56 and 3.83 ±0.53, Kappa = 0.572, P < 0.01 (ASIR group: 4.20 ± 0.48 and 4.10 ± 0.48, Kappa = 0.748, P < 0.01), by two observers. All images had acceptable diagnostic image quality. Conclusion: Lower radiation dose can be achieved by elevating NI with ASIR in pediatric CT abdominal studies, while maintaining diagnostically acceptable images. (authors)

  12. Radiation exposure during transmission measurements: comparison between CT- and germanium-based techniques with a current PET scanner

    International Nuclear Information System (INIS)

    Wu, Tung-Hsin; Huang, Yung-Hui; Lee, Jason J.S.; Wang, Shih-Yuan; Wang, Su-Cheng; Su, Cheng-Tau; Chen, Liang-Kung; Chu, Tieh-Chi

    2004-01-01

    In positron emission tomographic (PET) scanning, transmission measurements for attenuation correction are commonly performed by using external germanium-68 rod sources. Recently, combined PET and computed tomographic (CT) scanners have been developed in which the CT data can be used for both anatomical-metabolic image formation and attenuation correction of the PET data. The purpose of this study was to evaluate the difference between germanium- and CT-based transmission scanning in terms of their radiation doses by using the same measurement technique and to compare the doses that patients receive during brain, cardiac and whole-body scans. Measurement of absorbed doses to organs was conducted by using a Rando Alderson phantom with thermoluminescent dosimeters. Effective doses were calculated according to the guidelines in the International Commission on Radiation Protection Publication Number 60. Compared with radionuclide doses used in routine 2-[fluorine-18]-fluoro-2-deoxy-d-glucose PET imaging, doses absorbed during germanium-based transmission scans were almost negligible. On the other hand, absorbed doses from CT-based transmission scans were significantly higher, particularly with a whole-body scanning protocol. Effective doses were 8.81 mSv in the high-speed mode and 18.97 mSv in the high-quality mode for whole-body CT-based transmission scans. These measurements revealed that the doses received by a patient during CT-based transmission scanning are more than those received in a typical PET examination. Therefore, the radiation doses represent a limitation to the generalised use of CT-based transmission measurements with current PET/CT scanner systems. (orig.)

  13. Verification of CTDI and Dlp values for a head tomography reported by the manufacturers of the CT scanners, using a CT dose profiler probe, a head phantom and a piranha electrometer

    International Nuclear Information System (INIS)

    Castillo C, E.; Garcia F, I. B.; Garcia H, J.; Roman L, S.; Salmeron C, O.

    2015-10-01

    The extensive use of Computed Tomography (CT) and the associated increase in patient dose calls for an accurate dose evaluation technique. The CT contributes up to 70% of the total dose given to patients during X-ray examinations. The rapid advancements in CT technology are placing new demands on the methods and equipment that are used for quality assurance. The wide beam widths found in CT scanners with multiple beam apertures make it impossible to use existing CT ionization chambers to measure the total dose given to the patient. Using a standard 10 cm CT ionization chamber may result in inaccurate measurements due to underestimation of the dose profile for wide beams. The use a CT dose profiler based on solid-state technology and the Piranha electrometer from RTI electronics provides a potential solution to the arising concerns over patient dose. This study intend to evaluate the feasibility and accuracy of CT Dose Index (CTDI) and Dose Length Product (Dlp) values for a head tomography reported by the manufacturers of the CT scanners at each study. (Author)

  14. Verification of CTDI and Dlp values for a head tomography reported by the manufacturers of the CT scanners, using a CT dose profiler probe, a head phantom and a piranha electrometer

    Energy Technology Data Exchange (ETDEWEB)

    Castillo C, E.; Garcia F, I. B.; Garcia H, J.; Roman L, S. [Servicios de Salud de Michoacan, Centro Estatal de Atencion Oncologica, Gertrudis Bocanegra No. 300, Col. Cuauhtemoc, 58020 Morelia, Michoacan (Mexico); Salmeron C, O., E-mail: edithcastillocorona@gmail.com [Servicios de Salud de Michoacan, Hospital General Dr. Miguel Silva, Isidro Huarte s/n, Centro Historico, 58000 Morelia, Michoacan (Mexico)

    2015-10-15

    The extensive use of Computed Tomography (CT) and the associated increase in patient dose calls for an accurate dose evaluation technique. The CT contributes up to 70% of the total dose given to patients during X-ray examinations. The rapid advancements in CT technology are placing new demands on the methods and equipment that are used for quality assurance. The wide beam widths found in CT scanners with multiple beam apertures make it impossible to use existing CT ionization chambers to measure the total dose given to the patient. Using a standard 10 cm CT ionization chamber may result in inaccurate measurements due to underestimation of the dose profile for wide beams. The use a CT dose profiler based on solid-state technology and the Piranha electrometer from RTI electronics provides a potential solution to the arising concerns over patient dose. This study intend to evaluate the feasibility and accuracy of CT Dose Index (CTDI) and Dose Length Product (Dlp) values for a head tomography reported by the manufacturers of the CT scanners at each study. (Author)

  15. Radiation Changes the Metabolic Profiling of Melanoma Cell Line B16.

    Directory of Open Access Journals (Sweden)

    Lige Wu

    Full Text Available Radiation therapy can be an effective way to kill cancer cells using ionizing radiation, but some tumors are resistant to radiation therapy and the underlying mechanism still remains elusive. It is therefore necessary to establish an appropriate working model to study and monitor radiation-mediated cancer therapy. In response to cellular stress, the metabolome is the integrated profiling of changes in all metabolites in cells, which can be used to investigate radiation tolerance mechanisms and identify targets for cancer radiation sensibilization. In this study, using 1H nuclear magnetic resonance for untargeted metabolic profiling in radiation-tolerant mouse melanoma cell line B16, we comprehensively investigated changes in metabolites and metabolic network in B16 cells in response to radiation. Principal component analysis and partial least squares discriminant analysis indicated the difference in cellular metabolites between the untreated cells and X-ray radiated cells. In radiated cells, the content of alanine, glutamate, glycine and choline was increased, while the content of leucine, lactate, creatine and creatine phosphate was decreased. Enrichment analysis of metabolic pathway showed that the changes in metabolites were related to multiple metabolic pathways including the metabolism of glycine, arginine, taurine, glycolysis, and gluconeogenesis. Taken together, with cellular metabolome study followed by bioinformatic analysis to profile specific metabolic pathways in response to radiation, we deepened our understanding of radiation-resistant mechanisms and radiation sensibilization in cancer, which may further provide a theoretical and practical basis for personalized cancer therapy.

  16. SU-F-R-56: Early Assessment of Treatment Response During Radiation Therapy Delivery for Esophageal Cancer Using Quantitative CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, D [Henan Province Tumor Hospital, Zhengzhou, Henan (China); Chen, X; Li, X [Medical College of Wisconsin, Milwaukee, WI (United States); Wu, H [Medical college of Wisconsin, Milwaukee, WI (United States); Wang, J [Henan province Tumor hospital, Zhengzhou, Henan (China)

    2016-06-15

    Purpose: To investigate the feasibility of assessing treatment response using CTs during delivery of radiation therapy (RT) for esophageal cancer. Methods: Daily CTs acquired using a CT-on-Rails during the routine CT-guided RT for 20 patients with stage II to IV esophageal cancers were analyzed. All patients were treated with combined chemotherapy and IMRT of 45–50 Gy in 25 fractions, and were followed up for two years. Contours of GTV, spinal cord, and non-specified tissue (NST) irradiated with low dose were generated on each daily CT. A series of CT-texture metrics including Hounsfield Unit (HU) histogram, mean HU, standard derivation (STD), entropy, and energy were obtained in these contours on each daily CT. The changes of these metrics and GTV volume during RT delivery were calculated and correlated with treatment outcome. Results: Changes in CT texture (e.g., HU histogram) in GTV and spinal cord (but not in NST) were observed during RT delivery and were consistently increased with radiation dose. For the 20 cases studied, the mean HU in GTV was reduced on average by 4.0HU from the first to the last fractions, while 8 patients (responders) had larger reductions in GTV mean HU (average 7.8 HU) with an average GTV reduction of 51% and had increased consistently in GTV STD and entropy with radiation dose. The rest of 12 patients (non-responders) had lower reductions in GTV mean HU (average 1.5HU) and almost no change in STD and entropy. For the 8 responders, 2 experienced complete response, 7 (88%) survived and 1 died. In contrast, for the 12 non-responders, 4 (33%) survived and 8 died. Conclusion: Radiation can induce changes in CT texture in tumor (e.g., mean HU) during the delivery of RT for esophageal cancer. If validated with more data, such changes may be used for early prediction of RT response for esophageal cancer.

  17. The Addition of SPECT/CT Lymphoscintigraphy to Breast Cancer Radiation Planning Spares Lymph Nodes Critical for Arm Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Cheville, Andrea L., E-mail: Cheville.andrea@mayo.edu [Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, Minnesota (United States); Brinkmann, Debra H.; Ward, Shelly B. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Durski, Jolanta [Department of Radiology, Nuclear Medicine Program, Mayo Clinic, Rochester, Minnesota (United States); Laack, Nadia N.; Yan, Elizabeth; Schomberg, Paula J.; Garces, Yolanda I. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Suman, Vera J. [Department of Health Sciences Research, Mayo Clinic, Rochester, Minnesota (United States); Petersen, Ivy A. [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States)

    2013-03-15

    Background: This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. Methods: SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Results: Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. Conclusions: The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema.

  18. The addition of SPECT/CT lymphoscintigraphy to breast cancer radiation planning spares lymph nodes critical for arm drainage.

    Science.gov (United States)

    Cheville, Andrea L; Brinkmann, Debra H; Ward, Shelly B; Durski, Jolanta; Laack, Nadia N; Yan, Elizabeth; Schomberg, Paula J; Garces, Yolanda I; Suman, Vera J; Petersen, Ivy A

    2013-03-15

    This prospective cohort study was designed to determine whether the amount of radiation delivered to the nonpathological lymph nodes (LNs) that drain the arm can be significantly reduced by integrating single-photon emission computed tomography (SPECT)/computed tomography (CT) scans into radiation treatment planning. SPECT-CT scans were acquired for the 28 patients with stage I or II breast cancer and fused with the routinely obtained radiation oncology planning CT scans. Arm-draining LNs were contoured with 0.5-cm margins automatically using a threshold of 50% maximum intensity. Two treatment plans were generated: 1 per routine clinical practice (standard; STD) and the second (modified; MOD) with treatment fields modified to minimize dose to the arm-draining LNs visible on SPECT/CT images without interfering with the dosage delivered to target tissues. Participants were treated per the MOD plans. Arm volumes were measured prior to radiation and thereafter at least three subsequent 6-month intervals. Sixty-eight level I-III arm-draining LNs were identified, 57% of which were inside the STD plan fields but could be blocked in the MOD plan fields. Sixty-five percent of arm-draining LNs in the STD versus 16% in the MOD plans received a mean of ≥10 Gy, and 26% in the STD versus 4% in the MOD plans received a mean of ≥40 Gy. Mean LN radiation exposure was 23.6 Gy (standard deviation 18.2) with the STD and 7.7 Gy (standard deviation 11.3) with the MOD plans (P<.001). No participant developed lymphedema. The integration of SPECT/CT scans into breast cancer radiation treatment planning reduces unnecessary arm-draining LN radiation exposure and may lessen the risk of lymphedema. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    Science.gov (United States)

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  20. Significant Suppression of CT Radiation-Induced DNA Damage in Normal Human Cells by the PrC-210 Radioprotector.

    Science.gov (United States)

    Jermusek, Frank; Benedict, Chelsea; Dreischmeier, Emma; Brand, Michael; Uder, Michael; Jeffery, Justin J; Ranallo, Frank N; Fahl, William E

    2018-05-21

    While computed tomography (CT) is now commonly used and considered to be clinically valuable, significant DNA double-strand breaks (γ-H2AX foci) in white blood cells from adult and pediatric CT patients have been frequently reported. In this study to determine whether γ-H2AX foci and X-ray-induced naked DNA damage are suppressed by administration of the PrC-210 radioprotector, human blood samples were irradiated in a CT scanner at 50-150 mGy with or without PrC-210, and γ-H2AX foci were scored. X-ray-induced naked DNA damage was also studied, and the DNA protective efficacy of PrC-210 was compared against 12 other common "antioxidants." PrC-210 reduced CT radiation-induced γ-H2AX foci in white blood cells to near background ( P 95% DNA damage. A systemic PrC-210 dose known to confer 100% survival in irradiated mice had no discernible effect on micro-CT image signal-to-noise ratio and CT image integrity. PrC-210 suppressed DNA damage to background or near background in each of these assay systems, thus supporting its development as a radioprotector for humans in multiple radiation exposure settings.

  1. Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry

    Science.gov (United States)

    Dekker, Kurtis H.; Hazarika, Rubin; Silveira, Matheus A.; Jordan, Kevin J.

    2018-03-01

    Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large (⩾10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5–10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%–20% of the camera sensor’s range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes (∼15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.

  2. Reducing radiation dose in adult head CT using iterative reconstruction. A clinical study in 177 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kaul, D. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiology; Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiation Oncology; Kahn, J.; Huizing, L.; Wiener, E.; Grupp, U.; Boening, G.; Streitparth, F. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiology; Ghadjar, P. [Charite School of Medicine and University Hospital, Berlin (Germany). Dept. of Radiation Oncology; Renz, D.M. [Jena University Hospital (Germany). Dept. of Radiology

    2016-02-15

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n=71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n=86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n=74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n=20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n=20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p < 0.0001), respectively. Group B1 and group C1/2 also showed significantly reduced quantitative and qualitative image quality parameters. In group B2, quantitative measures were comparable to group A, and qualitative scores were lower compared to group A but higher compared to group B1. Diagnostic confidence grading showed groups B1/2 to be adequate for everyday clinical practice. Group C2 was considered acceptable for follow-up imaging of severe acute events such as bleeding or subacute stroke. Conclusion: Use of ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up.

  3. Reducing radiation dose in adult head CT using iterative reconstruction. A clinical study in 177 patients

    International Nuclear Information System (INIS)

    Kaul, D.; Charite School of Medicine and University Hospital, Berlin; Kahn, J.; Huizing, L.; Wiener, E.; Grupp, U.; Boening, G.; Streitparth, F.; Ghadjar, P.; Renz, D.M.

    2016-01-01

    To assess how ASIR (adaptive statistical iterative reconstruction) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT). Non-contrast emergency CT scans of the head acquired in 177 patients were evaluated. The scans were acquired and processed using four different protocols: Group A (control): 120 kV, FBP (filtered back projection) n=71; group B1: 120 kV, scan and reconstruction performed with 20 % ASIR (blending of 20 % ASIR and 80 % FBP), n=86; group B2: raw data from group B1 reconstructed using a blending of 40 % ASIR and 60 % FBP, n=74; group C1: 120 kV, scan and reconstruction performed with 30 % ASIR, n=20; group C2: raw data from group C1 reconstructed using a blending of 50 % ASIR and 50 % FBP, n=20. The effective dose was calculated. Image quality was assessed quantitatively and qualitatively. Compared to group A, groups B1/2 and C1/2 showed a significantly reduced effective dose of 40.4 % and 73.3 % (p < 0.0001), respectively. Group B1 and group C1/2 also showed significantly reduced quantitative and qualitative image quality parameters. In group B2, quantitative measures were comparable to group A, and qualitative scores were lower compared to group A but higher compared to group B1. Diagnostic confidence grading showed groups B1/2 to be adequate for everyday clinical practice. Group C2 was considered acceptable for follow-up imaging of severe acute events such as bleeding or subacute stroke. Conclusion: Use of ASIR makes it possible to reduce radiation significantly while maintaining adequate image quality in non-contrast head CT, which may be particularly useful for younger patients in an emergency setting and in follow-up.

  4. MR and CT findings of craniopharyngioma during and after radiation therapy

    International Nuclear Information System (INIS)

    Hamamoto, Y.; Niino, K.; Adachi, M.; Hosoya, T.

    2002-01-01

    Long-term changes in craniopharyngioma treated with radiation therapy (RT) were investigated by computed tomography (CT) and/or magnetic resonance (MR) imaging. Eight patients with craniopharyngioma were treated with incomplete resection or conservative surgical intervention followed by postoperative RT. The periods of tumor shrinkage were often long and varied (range: 6-68 months, mean: 29.1 months). Temporary enlargement of the solid component of a tumor usually occurs during RT and does not represent tumor progression. Cystic enlargement also occurs sometimes comparatively early after RT, and enlarged cysts often shrink with no treatment or with conservative treatment. These changes should be differentiated from tumor recurrence, with careful follow-up. After shrinkage, small solid or cystic nodules enhanced with contrast medium often remain. Long-term follow-up is necessary to differentiate uncontrolled tumors from controlled tumors with imaging modalities. (orig.)

  5. MR and CT findings of craniopharyngioma during and after radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Hamamoto, Y.; Niino, K.; Adachi, M.; Hosoya, T. [Department of Radiology, Yamagata University School of Medicine, Iidanishi, Yamagata (Japan)

    2002-02-01

    Long-term changes in craniopharyngioma treated with radiation therapy (RT) were investigated by computed tomography (CT) and/or magnetic resonance (MR) imaging. Eight patients with craniopharyngioma were treated with incomplete resection or conservative surgical intervention followed by postoperative RT. The periods of tumor shrinkage were often long and varied (range: 6-68 months, mean: 29.1 months). Temporary enlargement of the solid component of a tumor usually occurs during RT and does not represent tumor progression. Cystic enlargement also occurs sometimes comparatively early after RT, and enlarged cysts often shrink with no treatment or with conservative treatment. These changes should be differentiated from tumor recurrence, with careful follow-up. After shrinkage, small solid or cystic nodules enhanced with contrast medium often remain. Long-term follow-up is necessary to differentiate uncontrolled tumors from controlled tumors with imaging modalities. (orig.)

  6. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    Science.gov (United States)

    Yadav, Poonam; Kozak, Kevin; Tolakanahalli, Ranjini; Ramasubramanian, V.; Paliwal, Bhudatt R.; Welsh, James S.; Rong, Yi

    2012-01-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each “planning scan” to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields. PMID:21925866

  7. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    International Nuclear Information System (INIS)

    Yadav, Poonam; Kozak, Kevin; Tolakanahalli, Ranjini; Ramasubramanian, V.; Paliwal, Bhudatt R.; Welsh, James S.; Rong, Yi

    2012-01-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each “planning scan” to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

  8. Radiation dose reduction for CT lung cancer screening using ASIR and MBIR: a phantom study.

    Science.gov (United States)

    Mathieu, Kelsey B; Ai, Hua; Fox, Patricia S; Godoy, Myrna Cobos Barco; Munden, Reginald F; de Groot, Patricia M; Pan, Tinsu

    2014-03-06

    The purpose of this study was to reduce the radiation dosage associated with computed tomography (CT) lung cancer screening while maintaining overall diagnostic image quality and definition of ground-glass opacities (GGOs). A lung screening phantom and a multipurpose chest phantom were used to quantitatively assess the performance of two iterative image reconstruction algorithms (adaptive statistical iterative reconstruction (ASIR) and model-based iterative reconstruction (MBIR)) used in conjunction with reduced tube currents relative to a standard clinical lung cancer screening protocol (51 effective mAs (3.9 mGy) and filtered back-projection (FBP) reconstruction). To further assess the algorithms' performances, qualitative image analysis was conducted (in the form of a reader study) using the multipurpose chest phantom, which was implanted with GGOs of two densities. Our quantitative image analysis indicated that tube current, and thus radiation dose, could be reduced by 40% or 80% from ASIR or MBIR, respectively, compared with conventional FBP, while maintaining similar image noise magnitude and contrast-to-noise ratio. The qualitative portion of our study, which assessed reader preference, yielded similar results, indicating that dose could be reduced by 60% (to 20 effective mAs (1.6 mGy)) with either ASIR or MBIR, while maintaining GGO definition. Additionally, the readers' preferences (as indicated by their ratings) regarding overall image quality were equal or better (for a given dose) when using ASIR or MBIR, compared with FBP. In conclusion, combining ASIR or MBIR with reduced tube current may allow for lower doses while maintaining overall diagnostic image quality, as well as GGO definition, during CT lung cancer screening.

  9. Adaptive planning using megavoltage fan-beam CT for radiation therapy with testicular shielding

    Energy Technology Data Exchange (ETDEWEB)

    Yadav, Poonam [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Kozak, Kevin [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Tolakanahalli, Ranjini [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Ramasubramanian, V. [School of Advance Sciences, Vellore Institue of Technology University, Vellore, Tamil Nadu (India); Paliwal, Bhudatt R. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States); Welsh, James S. [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); Department of Medical Physics, University of Wisconsin, Madison, Madison, WI (United States); Rong, Yi, E-mail: rong@humonc.wisc.edu [Department of Human Oncology, University of Wisconsin, Madison, Madison, WI (United States); University of Wisconsin, Riverview Cancer Centre, Wisconsin Rapids, WI (United States)

    2012-07-01

    This study highlights the use of adaptive planning to accommodate testicular shielding in helical tomotherapy for malignancies of the proximal thigh. Two cases of young men with large soft tissue sarcomas of the proximal thigh are presented. After multidisciplinary evaluation, preoperative radiation therapy was recommended. Both patients were referred for sperm banking and lead shields were used to minimize testicular dose during radiation therapy. To minimize imaging artifacts, kilovoltage CT (kVCT) treatment planning was conducted without shielding. Generous hypothetical contours were generated on each 'planning scan' to estimate the location of the lead shield and generate a directionally blocked helical tomotherapy plan. To ensure the accuracy of each plan, megavoltage fan-beam CT (MVCT) scans were obtained at the first treatment and adaptive planning was performed to account for lead shield placement. Two important regions of interest in these cases were femurs and femoral heads. During adaptive planning for the first patient, it was observed that the virtual lead shield contour on kVCT planning images was significantly larger than the actual lead shield used for treatment. However, for the second patient, it was noted that the size of the virtual lead shield contoured on the kVCT image was significantly smaller than the actual shield size. Thus, new adaptive plans based on MVCT images were generated and used for treatment. The planning target volume was underdosed up to 2% and had higher maximum doses without adaptive planning. In conclusion, the treatment of the upper thigh, particularly in young men, presents several clinical challenges, including preservation of gonadal function. In such circumstances, adaptive planning using MVCT can ensure accurate dose delivery even in the presence of high-density testicular shields.

  10. Radiation exposure of patients during 68Ga-DOTATOC PET/CT examinations

    International Nuclear Information System (INIS)

    Hartmann, Holger; Freudenberg, R.; Oehme, L.; Andreeff, M.; Wunderlich, G.; Zoephel, K.; Eisenhofer, G.; Kotzerke, J.

    2009-01-01

    Investigation of the biodistribution and calculation of dosimetry of Ga-68-DOTATOC-for patients imaged in the routine clinical setting for diagnosis or exclusion of neuroendocrine tumours. Patients methods: Dynamic PET/CT-imaging (Biograph 16) was performed over 20 min in 14 patients (8 men, 6 women) after injection of (112 ± 22) MBq 68 Ga-DOTATOC followed by whole body 3D-acquisition (8 bed positions, 3 or 4 min each) 30 min p.i. and 120 min p.i., Urinary tracer elimination was measured and blood activity was derived non-invasively from the blood pool of the heart. The relevant organs for dosimetry were spleen, kidneys, liver, adrenals, urinary bladder and pituitary gland. Dosimetry was performed using OLINDA/EXM 1.0 software and specific organ uptake was expressed as standardized uptake values (SUVs). Results Rapid physiological uptake of the radiotracer could be demonstrated in liver, spleen and kidneys, adrenals and pituitary gland (mean SUVs were 6, 20, 16, 10, and 4, respectively). Radiotracer elimination was exclusively via urine (16% of injected dose within 2h); no redistribution could be observed. The spleen and the kidneys received the highest radiation exposure (0.24 mSv/MBq, 0.22 mSv/MBq resp.), mean effective dose yielded 0.023 mSv/MBq. Conclusion: 68 Ga-DOTATOC is used extensively for diagnosis of somatostatin receptor positive tumours because it has several advantages over the 111 In-labelled ligand. The derived dosimetric values are lower than first approximations from the biological data of OctreoScan. The use of CT for transmission correction of the PET data delivers radiation exposure up to 1 mSv (low dose). (orig.)

  11. Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni

    2013-12-01

    To evaluate dose reduction and image quality of abdominopelvic computed tomography (CT) reconstructed with model-based iterative reconstruction (MBIR) compared to adaptive statistical iterative reconstruction (ASIR). In this prospective study, 85 patients underwent referential-, low-, and ultralow-dose unenhanced abdominopelvic CT. Images were reconstructed with ASIR for low-dose (L-ASIR) and ultralow-dose CT (UL-ASIR), and with MBIR for ultralow-dose CT (UL-MBIR). Image noise was measured in the abdominal aorta and iliopsoas muscle. Subjective image analyses and a lesion detection study (adrenal nodules) were conducted by two blinded radiologists. A reference standard was established by a consensus panel of two different radiologists using referential-dose CT reconstructed with filtered back projection. Compared to low-dose CT, there was a 63% decrease in dose-length product with ultralow-dose CT. UL-MBIR had significantly lower image noise than L-ASIR and UL-ASIR (all pASIR and UL-ASIR (all pASIR in diagnostic acceptability (p>0.65), or diagnostic performance for adrenal nodules (p>0.87). MBIR significantly improves image noise and streak artifacts compared to ASIR, and can achieve radiation dose reduction without severely compromising image quality.

  12. Reducing Radiation Doses in Female Breast and Lung during CT Examinations of Thorax: A new Technique in two Scanners

    Directory of Open Access Journals (Sweden)

    Mehnati P.

    2017-09-01

    Full Text Available Background: Chest CT is a commonly used examination for the diagnosis of lung diseases, but a breast within the scanned field is nearly never the organ of interest. Objective: The purpose of this study is to compare the female breast and lung doses using split and standard protocols in chest CT scanning. Materials and Methods: The sliced chest and breast female phantoms were used. CT exams were performed using a single-slice (SS- and a 16 multi-slice (MS- CT scanner at 100 kVp and 120 kVp. Two different protocols, including standard and split protocols, were selected for scanning. The breast and lung doses were measured using thermo-luminescence dosimeters which were inserted into different layers of the chest and breast phantoms. The differences in breast and lung radiation doses in two protocols were studied in two scanners, analyzed by SPSS software and compared by t-test. Results: Breast dose by split scanning technique reduced 11% and 31% in SS- and MS- CT. Also, the radiation dose of lung tissue in this method decreased 18% and 54% in SS- and MS- CT, respectively. Moreover, there was a significant difference (p< 0.0001 in the breast and lung radiation doses between standard and split scanning protocols. Conclusion: The application of a split scan technique instead of standard protocol has a considerable potential to reduce breast and lung doses in SS- and MS- CT scanners. If split scanning protocol is associated with an optimum kV and MSCT, the maximum dose decline will be provided.

  13. The profile of CT scan findings in acute head trauma in Orotta ...

    African Journals Online (AJOL)

    In developing countries accident rates in general and ... injury refers to any damage to the scalp, skull, or brain. There are two ... and disability in children and adults in their most productive ... and gender distribution, and CT findings related to.

  14. An education and training programme for radiological institutes: impact on the reduction of the CT radiation dose

    International Nuclear Information System (INIS)

    Schindera, Sebastian T.; Allmen, Gabriel von; Vock, Peter; Szucs-Farkas, Zsolt; Treier, Reto; Trueb, Philipp R.; Nauer, Claude

    2011-01-01

    To establish an education and training programme for the reduction of CT radiation doses and to assess this programme's efficacy. Ten radiological institutes were counselled. The optimisation programme included a small group workshop and a lecture on radiation dose reduction strategies. The radiation dose used for five CT protocols (paranasal sinuses, brain, chest, pulmonary angiography and abdomen) was assessed using the dose-length product (DLP) before and after the optimisation programme. The mean DLP values were compared with national diagnostic reference levels (DRLs). The average reduction of the DLP after optimisation was 37% for the sinuses (180 vs. 113 mGycm, P < 0.001), 9% for the brain (982 vs. 896 mGycm, P < 0.05), 24% for the chest (425 vs. 322 mGycm, P < 0.05) and 42% for the pulmonary arteries (352 vs. 203 mGycm, P < 0.001). No significant change in DLP was found for abdominal CT. The post-optimisation DLP values of the sinuses, brain, chest, pulmonary arteries and abdomen were 68%, 10%, 20%, 55% and 15% below the DRL, respectively. The education and training programme for radiological institutes is effective in achieving a substantial reduction in CT radiation dose. (orig.)

  15. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose

  16. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    International Nuclear Information System (INIS)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung; Yoon, Choon-Sik; Choi, Jiin

    2015-01-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  17. Radiation dose and image quality in pediatric chest CT: effects of iterative reconstruction in normal weight and overweight children

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Haesung; Kim, Myung-Joon; Shin, Hyun Joo; Kim, Hyun Gi; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Choi, Jiin [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2015-03-01

    New CT reconstruction techniques may help reduce the burden of ionizing radiation. To quantify radiation dose reduction when performing pediatric chest CT using a low-dose protocol and 50% adaptive statistical iterative reconstruction (ASIR) compared with age/gender-matched chest CT using a conventional dose protocol and reconstructed with filtered back projection (control group) and to determine its effect on image quality in normal weight and overweight children. We retrospectively reviewed 40 pediatric chest CT (M:F = 21:19; range: 0.1-17 years) in both groups. Radiation dose was compared between the two groups using paired Student's t-test. Image quality including noise, sharpness, artifacts and diagnostic acceptability was subjectively assessed by three pediatric radiologists using a four-point scale (superior, average, suboptimal, unacceptable). Eight children in the ASIR group and seven in the control group were overweight. All radiation dose parameters were significantly lower in the ASIR group (P < 0.01) with a greater than 57% dose reduction in overweight children. Image noise was higher in the ASIR group in both normal weight and overweight children. Only one scan in the ASIR group (1/40, 2.5%) was rated as diagnostically suboptimal and there was no unacceptable study. In both normal weight and overweight children, the ASIR technique is associated with a greater than 57% mean dose reduction, without significantly impacting diagnostic image quality in pediatric chest CT examinations. However, CT scans in overweight children may have a greater noise level, even when using the ASIR technique. (orig.)

  18. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    International Nuclear Information System (INIS)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J.

    2016-01-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  19. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    Energy Technology Data Exchange (ETDEWEB)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland)

    2016-10-15

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  20. Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Hardie, Andrew D.; Felmly, Lloyd M.; Perry, Jonathan D.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Caruso, Damiano [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncological and Pathological Sciences, Latina (Italy); Canstein, Christian [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Siemens Medical Solutions USA, Malvern, PA (United States); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-02-15

    To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). We retrospectively analysed 200 patients (100 male, 100 female; mean age 61.2 ± 13.5 years, mean body mass index 27.5 ± 3.8 kg/m{sup 2}) equally divided into four groups matched by gender and body mass index, who had undergone portal venous phase abdominal CT with second-generation (group A, 120-kV-SECT; group B, 80/140-kV-DECT) and third-generation DSCT (group C, 100-kV-SECT; group D, 90/150-kV-DECT). The radiation dose was normalised for 40-cm scan length. Dose-independent figure-of-merit (FOM) contrast-to-noise ratios (CNRs) were calculated for various organs and vessels. Subjective overall image quality and reader confidence were assessed. The effective normalised radiation dose was significantly lower (P < 0.001) in groups C (6.2 ± 2.0 mSv) and D (5.3 ± 1.9 mSv, P = 0.103) compared to groups A (8.8 ± 2.3 mSv) and B (9.7 ± 2.4 mSv, P = 0.102). Dose-independent FOM-CNR peaked for liver, kidney, and portal vein measurements (all P ≤ 0.0285) in group D. Subjective image quality and reader confidence were consistently rated as excellent in all groups (all ≥1.53 out of 5). With both DSCT generations, abdominal DECT can be routinely performed without radiation dose penalty compared to SECT, while third-generation DSCT shows improved dose efficiency. (orig.)

  1. A dual energy CT study on vascular effects of gold nanoparticles in radiation therapy

    Science.gov (United States)

    Ashton, Jeffrey R.; Hoye, Jocelyn; Deland, Katherine; Whitley, Melodi; Qi, Yi; Moding, Everett; Kirsch, David G.; West, Jennifer; Badea, Cristian T.

    2016-03-01

    Gold nanoparticles (AuNPs) are emerging as promising agents for both cancer therapy and CT imaging. AuNPs are delivered to tumors via the enhanced permeability and retention effect and they preferentially accumulate in close proximity to the tumor blood vessels. AuNPs produce low-energy, short-range photoelectrons during external beam radiation therapy (RT), boosting dose. This work is focused on understanding how tumor vascular permeability is influenced by AuNP-augmented radiation therapy (RT), and how this knowledge can potentially improve the delivery of additional nanoparticle-based chemotherapeutics. We use dual energy (DE) CT to detect accumulation of AuNPs and increased vascular permeability to liposomal iodine (i.e. a surrogate for chemotherapeutics with liposome encapsulation) following RT. We used sarcoma tumors generated in LSL-KrasG12D; p53FL/FL conditional mutant mice. A total of n=37 mice were used in this study. The treated mice were injected with 20 mg AuNP (0.1 ml/25 g mouse) 24 hours before delivery of 5 Gy RT (n=5), 10 Gy RT (n=3) or 20 Gy RT (n=6). The control mice received no AuNP injection and either no RT (n=6), 5 Gy RT (n=3), 10 Gy RT (n=3), 20 Gy RT (n=11). Twenty four hours post-RT, the mice were injected with liposomal iodine (0.3 ml/25 mouse) and imaged with DE-CT three days later. The results suggest that independent of any AuNP usage, RT levels of 10 Gy and 20 Gy increase the permeability of tumor vasculature to liposomal iodine and that the increase in permeability is dose-dependent. We found that the effect of RT on vasculature may already be at its maximum response i.e. saturated at 20 Gy, and therefore the addition of AuNPs had almost no added benefit. Similarly, at 5 Gy RT, our data suggests that there was no effect of AuNP augmentation on tumor vascular permeability. However, by using AuNPs with 10 Gy RT, we observed an increase in the vascular permeability, however this is not yet statistically significant due to the small

  2. Radiation Dose and Image Quality from Coronary Angiography in 320-Detecor Row CT

    International Nuclear Information System (INIS)

    Thanomphudsa, J.; Krisanachinda, A.; Tumkosit, M.

    2012-01-01

    Introduction: Coronary Computed Tomography Angiography examinations are increasing rapidly. New Computed Tomography has been developed to improve image quality with the patient dose reduction. The purpose of this study is to evaluate radiation dose and image quality of Coronary Computed Tomography Angiography in patients using 320-detector row CT. Methods: Forty-one patients referred for cardiac CT examinations at King Chulalongkorn Memorial Hospital were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on the 320-detector row CT, Toshiba Aquilion One. Scanning protocol was investigated on dose estimates and image quality. Patients were scanned base on heart rate (HR) by HR 75 bpm use retrospective with dose modulation. Scanning parameters, kVp, mAs, HR, BMI, CTDIvol(mGy) and DLP(mGy.cm), were recorded to study the factors affecting the image quality and patient dose. And mA and kVp setting depend on BMI of the patient. Effective dose is calculated from DLP using specific conversion factor. The image quality was evaluated in 4 vessels by two radiologists. Noise assessment was also studied quantitatively. Results: The patient effective dose in prospective gating 70-80% was 3.6 ± 0.9 mSv, prospective gating 30-80% (1R-R) was 6.3 ± 1.9 mSv, and 30-80% (2R-R) was 10.8 ± 1.8 mSv and in retrospective with tube current modulation was 12.1± 7.7 mSv. Image noise was highest in PGT 70-80% 1R-R and decreased in RGT with tube current modulation, PGT 30-80% 1R-R and lowest in PGT 30-80% 2 R-R. And overall qualitative image quality was mostly good to excellent score. Discussion: The heart rate, heart rate variability and disease of the patient are affecting in the radiation dose and image quality so the suitable acquisition protocol used could be necessary. the effective dose and the image noise for the image quality. (author)

  3. [18F]fluoroethylcholine-PET/CT imaging for radiation treatment planning of recurrent and primary prostate cancer with dose escalation to PET/CT-positive lymph nodes

    Directory of Open Access Journals (Sweden)

    Wahl Andreas

    2011-05-01

    Full Text Available Abstract Background At present there is no consensus on irradiation treatment volumes for intermediate to high-risk primary cancers or recurrent disease. Conventional imaging modalities, such as CT, MRI and transrectal ultrasound, are considered suboptimal for treatment decisions. Choline-PET/CT might be considered as the imaging modality in radiooncology to select and delineate clinical target volumes extending the prostate gland or prostate fossa. In conjunction with intensity modulated radiotherapy (IMRT and imaged guided radiotherapy (IGRT, it might offer the opportunity of dose escalation to selected sites while avoiding unnecessary irradiation of healthy tissues. Methods Twenty-six patients with primary (n = 7 or recurrent (n = 19 prostate cancer received Choline-PET/CT planned 3D conformal or intensity modulated radiotherapy. The median age of the patients was 65 yrs (range 45 to 78 yrs. PET/CT-scans with F18-fluoroethylcholine (FEC were performed on a combined PET/CT-scanner equipped for radiation therapy planning. The majority of patients had intermediate to high risk prostate cancer. All patients received 3D conformal or intensity modulated and imaged guided radiotherapy with megavoltage cone beam CT. The median dose to primary tumours was 75.6 Gy and to FEC-positive recurrent lymph nodal sites 66,6 Gy. The median follow-up time was 28.8 months. Results The mean SUVmax in primary cancer was 5,97 in the prostate gland and 3,2 in pelvic lymph nodes. Patients with recurrent cancer had a mean SUVmax of 4,38. Two patients had negative PET/CT scans. At 28 months the overall survival rate is 94%. Biochemical relapse free survival is 83% for primary cancer and 49% for recurrent tumours. Distant disease free survival is 100% and 75% for primary and recurrent cancer, respectively. Acute normal tissue toxicity was mild in 85% and moderate (grade 2 in 15%. No or mild late side effects were observed in the majority of patients (84%. One patient had

  4. Patients with Testicular Cancer Undergoing CT Surveillance Demonstrate a Pitfall of Radiation-induced Cancer Risk Estimates: The Timing Paradox

    Science.gov (United States)

    Eisenberg, Jonathan D.; Lee, Richard J.; Gilmore, Michael E.; Turan, Ekin A.; Singh, Sarabjeet; Kalra, Mannudeep K.; Liu, Bob; Kong, Chung Yin; Gazelle, G. Scott

    2013-01-01

    Purpose: To demonstrate a limitation of lifetime radiation-induced cancer risk metrics in the setting of testicular cancer surveillance—in particular, their failure to capture the delayed timing of radiation-induced cancers over the course of a patient’s lifetime. Materials and Methods: Institutional review board approval was obtained for the use of computed tomographic (CT) dosimetry data in this study. Informed consent was waived. This study was HIPAA compliant. A Markov model was developed to project outcomes in patients with testicular cancer who were undergoing CT surveillance in the decade after orchiectomy. To quantify effects of early versus delayed risks, life expectancy losses and lifetime mortality risks due to testicular cancer were compared with life expectancy losses and lifetime mortality risks due to radiation-induced cancers from CT. Projections of life expectancy loss, unlike lifetime risk estimates, account for the timing of risks over the course of a lifetime, which enabled evaluation of the described limitation of lifetime risk estimates. Markov chain Monte Carlo methods were used to estimate the uncertainty of the results. Results: As an example of evidence yielded, 33-year-old men with stage I seminoma who were undergoing CT surveillance were projected to incur a slightly higher lifetime mortality risk from testicular cancer (598 per 100 000; 95% uncertainty interval [UI]: 302, 894) than from radiation-induced cancers (505 per 100 000; 95% UI: 280, 730). However, life expectancy loss attributable to testicular cancer (83 days; 95% UI: 42, 124) was more than three times greater than life expectancy loss attributable to radiation-induced cancers (24 days; 95% UI: 13, 35). Trends were consistent across modeled scenarios. Conclusion: Lifetime radiation risk estimates, when used for decision making, may overemphasize radiation-induced cancer risks relative to short-term health risks. © RSNA, 2012 Supplemental material: http

  5. Radiation exposure profile and dose estimates to flyers en route Frankfurt to Mumbai

    International Nuclear Information System (INIS)

    Rao, D.D.; Hegde, A.G.

    2010-01-01

    The earth is continuously bombarded by the high energy radiation (galactic radiation) from solar system commonly known as cosmic radiation. Intensity of cosmic ray radiation exposures change with altitude and increases rapidly with the increase in altitude from the earth. Passenger and cargo flights fly at different altitudes and therefore the crew and passengers are exposed to radiation levels significantly higher than the average background levels on the earth. A typical commercial jet aircraft fly at an altitude of 30,000 - 40,000 feet (9-12 km) and at these heights radiation exposure rates increase by about 100 times from the background levels. European countries have guidelines and suggestions on radiation exposure to air crew members in sectors that may potentially expose them to levels exceeding 1 mSv per annum. The paper details the radiation exposure profile recorded in Frankfurt-Dubai-Mumbai sector and evaluation of average radiation exposure received by the flyers and air crew members

  6. Accuracy and Radiation Dose of CT-Based Attenuation Correction for Small Animal PET: A Monte Carlo Simulation Study

    International Nuclear Information System (INIS)

    Yang, Ching-Ching; Chan, Kai-Chieh

    2013-06-01

    -Small animal PET allows qualitative assessment and quantitative measurement of biochemical processes in vivo, but the accuracy and reproducibility of imaging results can be affected by several parameters. The first aim of this study was to investigate the performance of different CT-based attenuation correction strategies and assess the resulting impact on PET images. The absorbed dose in different tissues caused by scanning procedures was also discussed to minimize biologic damage generated by radiation exposure due to PET/CT scanning. A small animal PET/CT system was modeled based on Monte Carlo simulation to generate imaging results and dose distribution. Three energy mapping methods, including the bilinear scaling method, the dual-energy method and the hybrid method which combines the kVp conversion and the dual-energy method, were investigated comparatively through assessing the accuracy of estimating linear attenuation coefficient at 511 keV and the bias introduced into PET quantification results due to CT-based attenuation correction. Our results showed that the hybrid method outperformed the bilinear scaling method, while the dual-energy method achieved the highest accuracy among the three energy mapping methods. Overall, the accuracy of PET quantification results have similar trend as that for the estimation of linear attenuation coefficients, whereas the differences between the three methods are more obvious in the estimation of linear attenuation coefficients than in the PET quantification results. With regards to radiation exposure from CT, the absorbed dose ranged between 7.29-45.58 mGy for 50-kVp scan and between 6.61-39.28 mGy for 80-kVp scan. For 18 F radioactivity concentration of 1.86x10 5 Bq/ml, the PET absorbed dose was around 24 cGy for tumor with a target-to-background ratio of 8. The radiation levels for CT scans are not lethal to the animal, but concurrent use of PET in longitudinal study can increase the risk of biological effects. The

  7. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung [Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Severance Children' s Hospital, Seoul (Korea, Republic of); Yoon, Choon-Sik [Yonsei University College of Medicine, Department of Radiology, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kim, Dong Wook; Hong, Jung Hwa [Yonsei University College of Medicine, Biostatistics Collaboration Unit, Seoul (Korea, Republic of)

    2014-12-15

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  8. Effects of adaptive statistical iterative reconstruction on radiation dose reduction and diagnostic accuracy of pediatric abdominal CT

    International Nuclear Information System (INIS)

    Bae, Sohi; Kim, Myung-Joon; Lee, Mi-Jung; Yoon, Choon-Sik; Kim, Dong Wook; Hong, Jung Hwa

    2014-01-01

    Since children are more radio-sensitive than adults, there is a need to minimize radiation exposure during CT exams. To evaluate the effects of adaptive statistical iterative reconstruction (ASIR) on radiation dose reduction, image quality and diagnostic accuracy in pediatric abdominal CT. We retrospectively reviewed the abdominal CT examinations of 41 children (24 boys and 17 girls; mean age: 10 years) with a low-dose radiation protocol and reconstructed with ASIR (the ASIR group). We also reviewed routine-dose abdominal CT examinations of 41 age- and sex-matched controls reconstructed with filtered-back projection (control group). Image quality was assessed objectively as noise measured in the liver, spleen and aorta, as well as subjectively by three pediatric radiologists for diagnostic acceptability using a four-point scale. Radiation dose and objective image qualities of each group were compared with the paired t-test. Diagnostic accuracy was evaluated by reviewing follow-up imaging studies and medical records in 2012 and 2013. There was 46.3% dose reduction of size-specific dose estimates in ASIR group (from 13.4 to 7.2 mGy) compared with the control group. Objective noise was higher in the liver, spleen and aorta of the ASIR group (P < 0.001). However, the subjective image quality was average or superior in 84-100% of studies. Only one image was subjectively rated as unacceptable by one reviewer. There was only one case with interpretational error in the control group and none in the ASIR group. Use of the ASIR technique resulted in greater than a 45% reduction in radiation dose without impairing subjective image quality or diagnostic accuracy in pediatric abdominal CT, despite increased objective image noise. (orig.)

  9. Electron bunch profile reconstruction in the few fs regime using coherent Smith-Purcell radiation

    International Nuclear Information System (INIS)

    Bartolini, R; Delerue, N; Doucas, G; Reichold, A; Clarke, C

    2012-01-01

    Advanced accelerators for fourth generation light sources based on high brightness linacs or laser-driven wakefield accelerators will operate with intense, highly relativistic electron bunches that are only a few fs long. Diagnostic techniques for the determination of temporal profile of such bunches are required to be non invasive, single shot, economic and with the required resolution in the fs regime. The use of a radiative process such as coherent Smith-Purcell radiation (SPR), is particularly promising with this respect. In this technique the beam is made to radiate a small amount of electromagnetic radiation and the temporal profile is reconstructed from the measured spectral distribution of the radiation. We summarise the advantages of SPR and present the design parameters and preliminary results of the experiments at the FACET facility at SLAC. We also discuss a new approach to the problem of the recovery of the 'missing phase', which is essential for the accurate reconstruction of the temporal bunch profile.

  10. Electron Bunch Profile Reconstruction in the Few fs Regime using Coherent Smith-Purcell Radiation

    International Nuclear Information System (INIS)

    Bartolini, R.; Clarke, C.; Delerue, N.; Doucasa, G.; Reicholda, A.

    2012-01-01

    Advanced accelerators for fourth generation light sources based on high brightness linacs or laser-driven wakefield accelerators will operate with intense, highly relativistic electron bunches that are only a few fs long. Diagnostic techniques for the determination of temporal profile of such bunches are required to be non invasive, single shot, economic and with the required resolution in the fs regime. The use of a radiative process such as coherent Smith-Purcell radiation (SPR), is particularly promising with this respect. In this technique the beam is made to radiate a small amount of electromagnetic radiation and the temporal profile is reconstructed from the measured spectral distribution of the radiation. We summarise the advantages of SPR and present the design parameters and preliminary results of the experiments at the FACET facility at SLAC. We also discuss a new approach to the problem of the recovery of the 'missing phase', which is essential for the accurate reconstruction of the temporal bunch profile.

  11. MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice

    International Nuclear Information System (INIS)

    Rehani, M; Samei, E; Morgan, W; Goske, M; Shore, R

    2014-01-01

    There are controversies surrounding radiation effects in human population in the range of radiation doses encountered by patients resulting from one to several CT scans. While it is understandable why the effects from low levels of diagnostic radiation are controversial, the situation is complicated by the media which may distort the known facts. There is need to understand the state of science regarding low-level radiation effects and also to understand how to communicate the potential risk with patients, the public and media. This session will seek to come to a consensus in order to speak with one voice to the media and the public. This session will review radiation effects known so far from a variety of exposed groups since the nuclear holocaust, provide clarification where effects are certain and where they are not, at what level extrapolation is the only way and at what level there is weak but agreeable acceptance. We will depict where and why there is agreement among organizations responsible for studying radiation effects, and how to deal with situations where effects are uncertain. Specific focus on radiation effects in children will be provided.Finally, the session will attempt to bridge the communication gap from the science to how to be an effective communicator with patients, parents, and media about ionizing radiation. Learning Objectives: To have a clear understanding about certainties and uncertainties of radiation effects at the level of a few CT scans To understand the results and limitations from 3 major pediatric CT scientific studies on childhood exposures published recently. To understand successful strategies used in risk communication

  12. MO-C-18C-01: Radiation Risks at Level of Few CT Scans: How Real?- Science to Practice

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, M [International Atomic Energy Agency, Vienna (Austria); Samei, E [Duke University Medical Center, Durham, NC (United States); Morgan, W [Pacific Northwest National Laboratory, Richland, WA (United States); Goske, M [Cincinnati Childrens Hospital, Cincinnati, OH (United States); Shore, R

    2014-06-15

    There are controversies surrounding radiation effects in human population in the range of radiation doses encountered by patients resulting from one to several CT scans. While it is understandable why the effects from low levels of diagnostic radiation are controversial, the situation is complicated by the media which may distort the known facts. There is need to understand the state of science regarding low-level radiation effects and also to understand how to communicate the potential risk with patients, the public and media. This session will seek to come to a consensus in order to speak with one voice to the media and the public. This session will review radiation effects known so far from a variety of exposed groups since the nuclear holocaust, provide clarification where effects are certain and where they are not, at what level extrapolation is the only way and at what level there is weak but agreeable acceptance. We will depict where and why there is agreement among organizations responsible for studying radiation effects, and how to deal with situations where effects are uncertain. Specific focus on radiation effects in children will be provided.Finally, the session will attempt to bridge the communication gap from the science to how to be an effective communicator with patients, parents, and media about ionizing radiation. Learning Objectives: To have a clear understanding about certainties and uncertainties of radiation effects at the level of a few CT scans To understand the results and limitations from 3 major pediatric CT scientific studies on childhood exposures published recently. To understand successful strategies used in risk communication.

  13. Collimation effects on the radiation detectors in the iCT image quality

    International Nuclear Information System (INIS)

    Carvalho, Diego Vergacas de Sousa; Kirita, Rodrigo; Mesquita, Carlos Henrique de; Hamada, Margarida Mizue; Ferreira, Erick Oliveira; Dantas, Carlos Costa

    2013-01-01

    This work studies the collimation effect in radiation detectors on the image quality of the iCT scanner, in which the path traversed by radiation beams is similar to a fan. The collimators were made of lead, 5 cm deep and 12 cm high, with rectangular holes (slits) of 2 x 5 mm, 4 x 10 mm (width x height) and circular hole of 5 mm diameter. The matrix images reconstructed from the data obtained with these collimation holes are presented. The spatial resolution of the image depends on the geometry of the collimator. One of the major advantages of narrow beam transmission tomography is the so-called hard field property. This property is capable of producing high quality images, though it decreases the count value and it takes a longer time. In contrast, a large collimation diameter produces a fuzzy image but with a faster scanning time. Moreover, the enlargement of the aperture from 2 x 5 mm to 4 x 10 mm barely affects the image quality. The aperture from 4 x 10 mm and 5 mm diameter presented similar quality image. (author)

  14. Collimation effects on the radiation detectors in the iCT image quality

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Diego Vergacas de Sousa; Kirita, Rodrigo; Mesquita, Carlos Henrique de; Hamada, Margarida Mizue, E-mail: dvcarvalho@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Ferreira, Erick Oliveira; Dantas, Carlos Costa [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear

    2013-07-01

    This work studies the collimation effect in radiation detectors on the image quality of the iCT scanner, in which the path traversed by radiation beams is similar to a fan. The collimators were made of lead, 5 cm deep and 12 cm high, with rectangular holes (slits) of 2 x 5 mm, 4 x 10 mm (width x height) and circular hole of 5 mm diameter. The matrix images reconstructed from the data obtained with these collimation holes are presented. The spatial resolution of the image depends on the geometry of the collimator. One of the major advantages of narrow beam transmission tomography is the so-called hard field property. This property is capable of producing high quality images, though it decreases the count value and it takes a longer time. In contrast, a large collimation diameter produces a fuzzy image but with a faster scanning time. Moreover, the enlargement of the aperture from 2 x 5 mm to 4 x 10 mm barely affects the image quality. The aperture from 4 x 10 mm and 5 mm diameter presented similar quality image. (author)

  15. Effects of radiation dose reduction in Volume Perfusion CT imaging of acute ischemic stroke

    International Nuclear Information System (INIS)

    Othman, Ahmed E.; Brockmann, Carolin; Afat, Saif; Pjontek, Rastislav; Nikobashman, Omid; Brockmann, Marc A.; Wiesmann, Martin; Yang, Zepa; Kim, Changwon; Kim, Jong Hyo

    2015-01-01

    To examine the influence of radiation dose reduction on image quality and sensitivity of Volume Perfusion CT (VPCT) maps regarding the detection of ischemic brain lesions. VPCT data of 20 patients with suspected ischemic stroke acquired at 80 kV and 180 mAs were included. Using realistic reduced-dose simulation, low-dose VPCT datasets with 144 mAs, 108 mAs, 72 mAs and 36 mAs (80 %, 60 %, 40 % and 20 % of the original levels) were generated, resulting in a total of 100 datasets. Perfusion maps were created and signal-to-noise-ratio (SNR) measurements were performed. Qualitative analyses were conducted by two blinded readers, who also assessed the presence/absence of ischemic lesions and scored CBV and CBF maps using a modified ASPECTS-score. SNR of all low-dose datasets were significantly lower than those of the original datasets (p <.05). All datasets down to 72 mAs (40 %) yielded sufficient image quality and high sensitivity with excellent inter-observer-agreements, whereas 36 mAs datasets (20 %) yielded poor image quality in 15 % of the cases with lower sensitivity and inter-observer-agreements. Low-dose VPCT using decreased tube currents down to 72 mAs (40 % of original radiation dose) produces sufficient perfusion maps for the detection of ischemic brain lesions. (orig.)

  16. Clinical assessment of CT-MRI image fusion software in localization of the prostate for 3D conformal radiation therapy

    International Nuclear Information System (INIS)

    Kagawa, Kazufumi; Lee, W. Robert; Schultheiss, Timothy E.; Hunt, Margie A.; Shaer, Andrew H.; Hanks, Gerald E.

    1996-01-01

    Purpose: To assess the utility of image fusion software and compare MRI prostate localization with CT localization in patients undergoing 3D conformal radiation therapy of prostate cancer. Materials and Methods: After a phantom study was performed to ensure the accuracy of image fusion procedure, 22 prostate cancer patients had CT and MRI studies before the start of radiotherapy. Immobilization casts used during radiation treatment were also used for both imaging studies. After the clinical target volume (CTV) (prostate or prostate + seminal vesicles) was defined on CT, slices from MRI study were reconstructed to match precisely the corresponding CT slices by identifying three common bony landmarks on each study. The CTV was separately defined on the matched MRI slices. Data related to the size and location of the prostate were compared between CT and MRI. The spatial relationship between the tip of urethrogram cone on CT and prostate apex seen on MRI was also scrutinized. Results: The phantom study showed the registration discrepancies between CT and MRI smaller than 1.0 mm in any pair of comparison. The patient study showed mean image registration error of 0.9 (± 0.6) mm. The average prostate volume was 63.0 (± 25.8) cm 3 and 50.9 (± 22.9) cm 3 determined by CT and MRI respectively (Fig. 1). The difference in prostate location with the two studies most commonly differed at the base and at the apex of the prostate (Fig. 2). On transverse MRI, the prostate apex was situated 7.1 (± 4.5) mm dorsal and 15.1 (± 4.0) mm cephalad to the tip of urethrogram cone (Fig. 3). Conclusions: CT-MRI image fusion study made it possible to compare the two modalities directly. MRI localization of the prostate is more accurate than CT, and indicates the distance from cone to apex is 15 mm. In view of excellent treatment results obtained with current CT localization of the prostate, still it may not be wise to reduce target volume to that demonstrated on MRI

  17. Dual energy CT intracranial angiography: image quality, radiation dose and initial application results

    International Nuclear Information System (INIS)

    Chai Xue; Zhang Longjiang; Lu Guangming; Zhou Changsheng

    2009-01-01

    Objective: To assess the clinical value of dual-energy intracranial CT angiography (CTA). Methods: Forty-one patients suspected of intracranial vascular diseases underwent dual-energy intracranial CT angiography, and 41 patients who underwent conventional subtraction CT were enrolled as the control group. Image quality of intracranial and skull base vessels and radiation dose between dual-energy CTA and conventional subtraction CTA were compared using two independent sample nonparametric test and independent-samples t test, respectively. Prevalence and size of lesions detected by dual-energy CTA and digital subtraction CTA were compared using paired-samples t test and Spearman correlative analysis. Results: The percentage of image quality scored 5 was 70.7% (29/41) for dual-energy CTA and 75.6% (31/41) for conventional subtraction CTA. There was no significant difference between the two groups (Z= -0.455, P=0.650). Image quality of vessels at the skull base in conventional subtraction CTA was superior to that in dual-energy CTA, especially for the petrosal and syphon segment (Z=-4.087, P=0.000). Radiation exposure of dual energy CTA and conventional CTA were (396.54±17.43) and (1090.95±114.29) mGy·cm respectively. Radiation exposure was decreased by 64% (t=-38.52, P=0.000) by dual energy CTA compared with conventional subtraction CTA. Out of the 41 patients, 19 patients were diagnosed as intracranial aneurysm, 2 patients as arteriovenous malformation (AVM), 3 patients with Moya-moya's disease, and the remaining 17 patients with negative results. Nine patients with intracranial aneurysm, 2 patients with AVM, 3 patients with Moya-moya's disease, and 2 patients with negative findings underwent DSA or operation, with concordant findings from both techniques. Diameter of aneurysm neck, long axis and minor axis by dual-energy CTA was (2.90±1.61), (5.23±1.68) and (3.83±1.69) mm, respectively; Diameter of aneurysm neck, long axis and minor axis by DSA was (2.95±1

  18. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.d [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany); Walcher, Felix; Marzi, Ingo [Department of Trauma, Hand and Reconstructive Surgery, University of Frankfurt, Frankfurt (Germany); Moritz, Anton [Department of Thoracic and Cardiovascular Surgery, University of Frankfurt, Frankfurt (Germany); Vogl, Thomas J.; Mack, Martin G. [Department of Diagnostic and Interventional Radiology, University of Frankfurt, Frankfurt (Germany)

    2010-07-15

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  19. CT-guided pericardiocenteses: Clinical profile, practice patterns and clinical outcome

    International Nuclear Information System (INIS)

    Eichler, Katrin; Zangos, Stephan; Thalhammer, Axel; Jacobi, Volkmar; Walcher, Felix; Marzi, Ingo; Moritz, Anton; Vogl, Thomas J.; Mack, Martin G.

    2010-01-01

    Objective: To assess the effectiveness and clinical outcome and technique of CT-guided pericardiocenteses in the treatment of pericardial effusions in adults and children. Methods: 20 drainages were performed in Seldinger-technique under CT-guidance on 20 patients suffering from pericardial effusions and haematomas. In 85%, the etiology of effusion was postoperative. The mean age of the patients was 59 years (minimum 9 years, maximum 86 years).There were 12 male and eight female patients. The inclusion criterion was an echocardiographically relevant proved pericardial effusion. Results: All catheters could be placed successfully (20/20) in the pericardial effusion and allowed for draining of the effusion in all cases under CT-guidance. The overall 30-day mortality rate was 0%. CT-guided pericardiocentesis was successful for withdrawing pericardial fluid and/or relieving tamponade in 100% of all procedures. No major complication was occurred. A total of one minor complication (5%) occurred that required no specific interventions, except for monitoring and appropriate follow-up. We observed one pneumothorax as a minor complication. Conclusions: Pericardial effusions of various causes can be safely, effectively, and quickly managed with CT-guided pericardiocenteses in adults and children. The ventrolateral entry side for the puncture should be preferred to reach the whole effusion and avoid complications, like a pneumothorax.

  20. Size-appropriate radiation doses in pediatric body CT: a study of regional community adoption in the United States

    International Nuclear Information System (INIS)

    Hopkins, Katharine L.; Vajtai, Petra L.; Pettersson, David R.; Spinning, Kristopher; Beckett, Brooke R.; Koudelka, Caroline W.; Bardo, Dianna M.E.

    2013-01-01

    During the last decade, there has been a movement in the United States toward utilizing size-appropriate radiation doses for pediatric body CT, with smaller doses given to smaller patients. This study assesses community adoption of size-appropriate pediatric CT techniques. Size-specific dose estimates (SSDE) in pediatric body scans are compared between community facilities and a university children's hospital that tailors CT protocols to patient size as advocated by Image Gently. We compared 164 pediatric body scans done at community facilities (group X) with 466 children's hospital scans. Children's hospital scans were divided into two groups: A, 250 performed with established pediatric weight-based protocols and filtered back projection; B, 216 performed with addition of iterative reconstruction technique and a 60% reduction in volume CT dose index (CTDI vol ). SSDE was calculated and differences among groups were compared by regression analysis. Mean SSDE was 1.6 and 3.9 times higher in group X than in groups A and B and 2.5 times higher for group A than group B. A model adjusting for confounders confirmed significant differences between group pairs. Regional community hospitals and imaging centers have not universally adopted child-sized pediatric CT practices. More education and accountability may be necessary to achieve widespread implementation. Since even lower radiation doses are possible with iterative reconstruction technique than with filtered back projection alone, further exploration of the former is encouraged. (orig.)

  1. The relation of CT-determined tumor parameters and local and regional outcome of tonsillar cancer after definitive radiation treatment

    International Nuclear Information System (INIS)

    Hermans, Robert; Op de beeck, Katya; Bogaert, Walter van den; Rijnders, Alexis; Staelens, Lorenzo; Feron, Michel; Bellon, Erwin

    2001-01-01

    Purpose: To investigate the value of CT-derived tumor parameters as predictor of local and regional outcome of tonsillar squamous cell carcinoma treated by definitive radiation therapy. Methods and Materials: The pretreatment CT studies of 112 patients with tonsillar squamous cell carcinoma were reviewed. After redigitizing the films, primary and nodal tumor volume was calculated with the summation-of-areas technique. The nodal CT aspect was graded using a 3-point scale (homogenous, inhomogeneous, and necrotic). Mean follow-up time was 33 months. Actuarial statistical analysis of local and regional outcome was done for each of the covariates; multivariate analysis was performed using Cox's proportional hazards model. Results: In the actuarial analysis, CT-determined primary tumor volume was significantly correlated with local recurrence rate (p<0.05) when all patients were considered, but primary tumor volume did not predict local control within the T2, T3, and T4 category. CT-determined nodal volume was significantly related to regional outcome (p<0.01), but nodal density was not. Total tumor volume was not significantly related to locoregional outcome (p=0.1). In the multivariate analysis, the T and N categories were the independent predictors of local and regional outcomes, respectively. Conclusion: Compared to other head-and-neck sites, primary and nodal tumor volume have only marginal predictive value regarding local and regional outcome after radiation therapy in tonsillar cancer

  2. Size-appropriate radiation doses in pediatric body CT: a study of regional community adoption in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Hopkins, Katharine L.; Vajtai, Petra L. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Pettersson, David R.; Spinning, Kristopher; Beckett, Brooke R. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Koudelka, Caroline W. [Oregon Health and Science University, Division of Biostatistics, Department of Public Health and Preventive Medicine, Portland, OR (United States); Bardo, Dianna M.E. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Cardiovascular Medicine, Portland, OR (United States)

    2013-09-15

    During the last decade, there has been a movement in the United States toward utilizing size-appropriate radiation doses for pediatric body CT, with smaller doses given to smaller patients. This study assesses community adoption of size-appropriate pediatric CT techniques. Size-specific dose estimates (SSDE) in pediatric body scans are compared between community facilities and a university children's hospital that tailors CT protocols to patient size as advocated by Image Gently. We compared 164 pediatric body scans done at community facilities (group X) with 466 children's hospital scans. Children's hospital scans were divided into two groups: A, 250 performed with established pediatric weight-based protocols and filtered back projection; B, 216 performed with addition of iterative reconstruction technique and a 60% reduction in volume CT dose index (CTDI{sub vol}). SSDE was calculated and differences among groups were compared by regression analysis. Mean SSDE was 1.6 and 3.9 times higher in group X than in groups A and B and 2.5 times higher for group A than group B. A model adjusting for confounders confirmed significant differences between group pairs. Regional community hospitals and imaging centers have not universally adopted child-sized pediatric CT practices. More education and accountability may be necessary to achieve widespread implementation. Since even lower radiation doses are possible with iterative reconstruction technique than with filtered back projection alone, further exploration of the former is encouraged. (orig.)

  3. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    Directory of Open Access Journals (Sweden)

    Holger Wenz

    2016-01-01

    Conclusions: Spiral cCT combined with ATCM and IR allows for significant-radiation dose reduction including a reduce eye lens organ-dose when compared to a tilted sequential cCT while improving subjective and objective image quality.

  4. Implementation of a split-bolus single-pass CT protocol at a UK major trauma centre to reduce excess radiation dose in trauma pan-CT

    International Nuclear Information System (INIS)

    Leung, V.; Sastry, A.; Woo, T.D.; Jones, H.R.

    2015-01-01

    Aim: To quantify the dose reduction and ensure that the use of a split-bolus protocol provided sufficient vascular enhancement. Materials and methods: Between 1 January 2014 and 31 May 2014, both split bolus and traditional two-phase scans were performed on a single CT scanner (SOMATOM Definition AS+, Siemens Healthcare) using a two-pump injector (Medrad Stellant). Both protocols used Siemens' proprietary tube current and tube voltage modulation techniques (CARE dose and CARE kV). The protocols were compared retrospectively to assess the dose–length product (DLP), aortic radiodensity at the level of the coeliac axis and radiodensity of the portal vein. Results: There were 151 trauma CT examinations during this period. Seventy-eight used the split-bolus protocol. Seventy-one had traditional two-phase imaging. One patient was excluded as they were under the age of 18 years. The radiodensity measurements for the portal vein were significantly higher (p<0.001) in the split-bolus protocol. The mean aortic enhancement in both protocols exceeded 250 HU, although the traditional two-phase protocol gave greater arterial enhancement (p<0.001) than the split-bolus protocol. The split-bolus protocol had a significantly lower (p<0.001) DLP with 43.5% reduction in the mean DLP compared to the traditional protocol. Conclusion: Split-bolus CT imaging offers significant dose reduction for this relatively young population while retaining both arterial and venous enhancement. -- Highlights: •We implemented a split bolus pan-CT protocol for trauma CT. •We compared the radiation dose and vascular enhancement of the split bolus protocol to a traditional two phase protocol. •The split bolus protocol had a 43.5% reduction in mean DLP

  5. Status of multigroup sensitivity profiles and covariance matrices available from the radiation shielding information center

    International Nuclear Information System (INIS)

    Roussin, R.W.; Drischler, J.D.; Marable, J.H.

    1980-01-01

    In recent years multigroup sensitivity profiles and covariance matrices have been added to the Radiation Shielding Information Center's Data Library Collection (DLC). Sensitivity profiles are available in a single package. DLC-45/SENPRO, and covariance matrices are found in two packages, DLC-44/COVERX and DLC-77/COVERV. The contents of these packages are described and their availability is discussed

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  7. Radiation dose reduction sinogram affirmed iterative reconstruction and automatic tube voltage modulation(CARE kV) in abdominal CT

    International Nuclear Information System (INIS)

    Shin, Hyun Joo; Chung, Yong Eun; Lee, Young Han; Choi, Jin Young; Park, Mi Suk; Kim, Myeong Jin; Kim, Ki Whang

    2013-01-01

    To evaluate the feasibility of sinogram-affirmed iterative reconstruction (SAFIRE) and automated kV modulation (CARE kV) in reducing radiation dose without increasing image noise for abdominal CT examination. This retrospective study included 77 patients who received CT imaging with an application of CARE kV with or without SAFIRE and who had comparable previous CT images obtained without CARE kV or SAFIRE, using the standard dose (i.e., reference mAs of 240) on an identical CT scanner and reconstructed with filtered back projection (FBP) within 1 year. Patients were divided into two groups: group A (33 patients, CT scanned with CARE kV); and group B (44 patients, scanned after reducing the reference mAs from 240 to 170 and applying both CARE kV and SAFIRE). CT number, image noise for four organs and radiation dose were compared among the two groups. Image noise increased after CARE kV application (p < 0.001) and significantly decreased as SAFIRE strength increased (p < 0.001). Image noise with reduced-mAs scan (170 mAs) in group B became similar to that of standard-dose FBP images after applying CARE kV and SAFIRE strengths of 3 or 4 when measured in the aorta, liver or muscle (p ≥ 0.108). Effective doses decreased by 19.4% and 41.3% for groups A and B, respectively (all, p < 0.001) after application of CARE kV with or without SAFIRE. Combining CARE kV, reduction of mAs from 240 to 170 mAs and noise reduction by applying SAFIRE strength 3 or 4 reduced the radiation dose by 41.3% without increasing image noise compared with the standard-dose FBP images.

  8. A case of chronic progressive radiation myelopathy with a CT myelogram simulating intramedullary tumor

    International Nuclear Information System (INIS)

    Kanemaru, Kazutomi; Kamo, Hisaki; Yamao, Satoshi; Akiguchi, Ichiro; Kameyama, Masakuni

    1985-01-01

    A 58-year-old man underwent a right middle lobectomy in June, 1975, for poorly differentiated adenocarcinoma of the lung. Postoperative irradiation was given to the hilus (6100 rads), and to the right supraclavicular area (6000 rads). In 1980, 60 months after completion of irradiation, the patient noticed weakness of his legs particularly on the left side. In 1982, he noticed the girdle sensation in the upper thoracic region, and paresthesia in the lateral side of the right thigh. In Dec 1983, micturition disturbance appeared, and gait disturbance progressed, he was admitted to the Kyoto University Hospital. Neurological examination revealed an incomplete left Brown-Sequard syndrome with diminution of pain and thermal sensation on the right lower limb, and weakness and spasticity particularly on the left lower limb. Conventional myelogram with CT myelogram showed spinal cord swelling from T-2 through T-5. No extramedullary lesion was found. Laminectomy was performed through T-1 to T-6. When the dura was opened, the cord was swollen and necrotic with a cyst formation. Microscopic examination of the thickened part of the cord showed necrosis and gliosis. The lesion was correspond to the cord segments exposed to the radiation, and a diagnosis of radiation myelopathy was made. Several cases of radiation myelopathy with definite swelling of the cord at myelography were reported, but myelography in these cases was performed at most within 11 months after the onset. In this case, myelography was performed three years after the onset, and revealed difinite swelling of the cord due to a cyst formation. (author)

  9. Case of chronic progressive radiation myelopathy with a CT myelogram simulating intramedullary tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kanemaru, Kazutomi; Kamo, Hisaki; Yamao, Satoshi; Akiguchi, Ichiro; Kameyama, Masakuni

    1985-05-01

    A 58-year-old man underwent a right middle lobectomy in June, 1975, for poorly differentiated adenocarcinoma of the lung. Postoperative irradiation was given to the hilus (6100 rads), and to the right supraclavicular area (6000 rads). In 1980, 60 months after completion of irradiation, the patient noticed weakness of his legs particularly on the left side. In 1982, he noticed the girdle sensation in the upper thoracic region, and paresthesia in the lateral side of the right thigh. In Dec 1983, micturition disturbance appeared, and gait disturbance progressed, he was admitted to the Kyoto University Hospital. Neurological examination revealed an incomplete left Brown-Sequard syndrome with diminution of pain and thermal sensation on the right lower limb, and weakness and spasticity particularly on the left lower limb. Conventional myelogram with CT myelogram showed spinal cord swelling from T-2 through T-5. No extramedullary lesion was found. Laminectomy was performed through T-1 to T-6. When the dura was opened, the cord was swollen and necrotic with a cyst formation. Microscopic examination of the thickened part of the cord showed necrosis and gliosis. The lesion was correspond to the cord segments exposed to the radiation, and a diagnosis of radiation myelopathy was made. Several cases of radiation myelopathy with definite swelling of the cord at myelography were reported, but myelography in these cases was performed at most within 11 months after the onset. In this case, myelography was performed three years after the onset, and revealed difinite swelling of the cord due to a cyst formation. (author).

  10. Caffeic acid phenethyl ester preferentially sensitizes CT26 colorectal adenocarcinoma to ionizing radiation without affecting bone marrow radioresponse

    International Nuclear Information System (INIS)

    Chen, Y.-J.; Liao, H.-F.; Tsai, T.-H.; Wang, S.-Y.; Shiao, M.-S.

    2005-01-01

    Purpose: Caffeic acid phenethyl ester (CAPE), a component of propolis, was reported capable of depleting glutathione (GSH). We subsequently examined the radiosensitizing effect of CAPE and its toxicity. Methods and Materials: The effects of CAPE on GSH level, GSH metabolism enzyme activities, NF-κB activity, and radiosensitivity in mouse CT26 colorectal adenocarcinoma cells were determined. BALB/c mouse with CT26 cells implantation was used as a syngeneic in vivo model for evaluation of treatment and toxicity end points. Results: CAPE entered CT26 cells rapidly and depleted intracellular GSH in CT26 cells, but not in bone marrow cells. Pretreatment with nontoxic doses of CAPE significantly enhanced cell killing by ionizing radiation (IR) with sensitizer enhancement ratios up to 2.2. Pretreatment of CT26 cells with N-acetyl-L-cysteine reversed the GSH depletion activity and partially blocked the radiosensitizing effect of CAPE. CAPE treatment in CT26 cells increased glutathione peroxidase, decreased glutathione reductase, and did not affect glutathione S-transferase or γ-glutamyl transpeptidase activity. Radiation activated NF-κB was reversed by CAPE pretreatment. In vivo study revealed that pretreatment with CAPE before IR resulted in greater inhibition of tumor growth and prolongation of survival in comparison with IR alone. Pretreatment with CAPE neither affected body weights nor produced hepatic, renal, or hematopoietic toxicity. Conclusions: CAPE sensitizes CT26 colorectal adenocarcinoma to IR, which may be via depleting GSH and inhibiting NF-κB activity, without toxicity to bone marrow, liver, and kidney

  11. Research on the radiation doses to adults receiving from main types of medical X-ray CT examinations

    International Nuclear Information System (INIS)

    Gao Linfeng; Wang Bin; Yao Jie; Qian Aijun; Zheng Junzheng; Zhuo Weihai; Qu Liangyong

    2013-01-01

    To study and master the doses to examinees receiving from the wide spread X-CT examinations, is a key issue for strengthening the medical radiation protection. In the studies of the medical exposure levels during the Eleventh Five-Year Plan period in Shanghai, based on the brands of X-CT scanners and their distributions in different levels of hospitals, a total of 45 sets (about 30% of all) of scanners were selected for the field study. Among the 8 commonly performed examinations, the scan parameters and their relevant dosimetry information for 500 adults were collected, and their typical effective doses were estimated with the dose conversion factors. The results showed that the averages of weighted CT dose index (CTDI w ) were 55.4, 12.5 and 18.4 mGy, and the dose length products (DLP) were averaged to be 603, 294 and 415 mGy·cm, for the skull, chest and abdomen X-CT scans, respectively. The typical effective doses were estimated to be 1.4, 5.3, and 7.5 mSv for adults in the head, chest and abdomen X-CT scans, respectively. The values of CTDI w for skull scans were generally higher than those for the ear canal, eye, or sinus examinations. It is clear that the optimization between the image quality and the radiation dose should be further strengthened. Particular attentions should be paid in selecting the scanning parameters for various types of X-CT scans, and the diagnostic reference levels for X-CT examinations should be continuously improved. (authors)

  12. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Hein, Eike; Rogalla, Patrik; Klingebiel, Randolph; Hamm, Bernd [Department of Diagnostic and Interventional Radiology, Charite Hospital, Humboldt-Universitaet zu Berlin (Germany)

    2002-07-01

    The purpose of the study was to assess the effect of lens protection on image quality and radiation dose to the eye lenses in CT of the paranasal sinuses. In 127 patients referred to rule out sinusitis, an axial spiral CT with a lens protection placed on the patients eyes was obtained (1.5/2/1, 50 mAs, 120 kV). Coronal views were reconstructed at 5-mm interval. To quantify a subjective impression of image quality, three regions of interest within the eyeball were plotted along a line perpendicular to the protection at 2, 5, and 9 mm beneath skin level on the axial images. Additionally, dose reduction of a bismuth-containing latex shield was measured using a film-dosimetry technique. The average eyeball density was 17.97 HU (SD 3.7 HU). The relative increase in CT density was 180.6 (17.7), 103.3 (11.7), and 53.6 HU (9.2), respectively. There was no diagnostic information loss on axial and coronal views observed. Artifacts were practically invisible on images viewed in a bone window/level setting. The use of the shield reduced skin radiation from 7.5 to 4.5 mGy. The utilization of a radioprotection to the eye lenses in paranasal CT is a suitable and effective means of reducing skin radiation by 40%. (orig.)

  13. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose

    International Nuclear Information System (INIS)

    Hein, Eike; Rogalla, Patrik; Klingebiel, Randolph; Hamm, Bernd

    2002-01-01

    The purpose of the study was to assess the effect of lens protection on image quality and radiation dose to the eye lenses in CT of the paranasal sinuses. In 127 patients referred to rule out sinusitis, an axial spiral CT with a lens protection placed on the patients eyes was obtained (1.5/2/1, 50 mAs, 120 kV). Coronal views were reconstructed at 5-mm interval. To quantify a subjective impression of image quality, three regions of interest within the eyeball were plotted along a line perpendicular to the protection at 2, 5, and 9 mm beneath skin level on the axial images. Additionally, dose reduction of a bismuth-containing latex shield was measured using a film-dosimetry technique. The average eyeball density was 17.97 HU (SD 3.7 HU). The relative increase in CT density was 180.6 (17.7), 103.3 (11.7), and 53.6 HU (9.2), respectively. There was no diagnostic information loss on axial and coronal views observed. Artifacts were practically invisible on images viewed in a bone window/level setting. The use of the shield reduced skin radiation from 7.5 to 4.5 mGy. The utilization of a radioprotection to the eye lenses in paranasal CT is a suitable and effective means of reducing skin radiation by 40%. (orig.)

  14. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    Energy Technology Data Exchange (ETDEWEB)

    Klasic, B. [Hospital for pulmonary diseases, Zagreb (Croatia); Knezevic, Z.; Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Brnic, Z.; Novacic, K. [Merkur Univ. Hospital, Zagreb (Croatia)

    2006-07-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  15. Scatter radiation breast exposure during head CT: impact of scanning conditions and anthropometric parameters on shielded and unshielded breast dose

    International Nuclear Information System (INIS)

    Klasic, B.; Knezevic, Z.; Vekic, B.; Brnic, Z.; Novacic, K.

    2006-01-01

    Constantly increasing clinical requests for CT scanning of the head on our facility continue to raise concern regarding radiation exposure of patients, especially radiosensitive tissues positioned close to the scanning plane. The aim of our prospective study was to estimate scatter radiation doses to the breast from routine head CT scans, both with and without use of lead shielding, and to establish influence of various technical and anthropometric factors on doses using statistical data analysis. In 85 patient referred to head CT for objective medical reasons, one breast was covered with lead apron during CT scanning. Radiation doses were measured at skin of both breasts and over the apron simultaneously, by the use of thermo luminescent dosimeters. The doses showed a mean reduction by 37% due to lead shielding. After we statistically analyzed our data, we observed significant correlation between under-the-shield dose and values of technical parameters. We used multiple linear regression model to describe the relationships of doses to unshielded and shielded breast respectively, with anthropometric and technical factors. Our study proved lead shielding of the breast to be effective, easy to use and leading to a significant reduction in scatter dose. (author)

  16. Clinical application of 'Justification' and 'Optimization' principle of ALARA in pediatric CT imaging: "How many children can be protected from unnecessary radiation?".

    Science.gov (United States)

    Sodhi, Kushaljit S; Krishna, Satheesh; Saxena, Akshay K; Sinha, Anindita; Khandelwal, Niranjan; Lee, Edward Y

    2015-09-01

    Practice of ALARA (as low as reasonably achievable) principle in the developed world is currently well established. However, there is striking lack of published data regarding such experience in the developing countries. Therefore, the goal of this study is to prospectively evaluate CT request forms to assess how many children could be protected from harmful radiation exposure if 'Justification' and 'Optimization' principles of ALARA are applied before obtaining CT imaging in a developing country. This can save children from potential radiation risks including development of brain cancer and leukemia. Consecutive CT request forms over a six month study period (May 16, 2013 to November 15, 2013) in a tertiary pediatric children's hospital in India were prospectively reviewed by two pediatric radiologists before obtaining CT imaging. First, 'Justification' of CT was evaluated and then 'Optimization' was applied for evaluation of appropriateness of the requested CT studies. The number (and percentage) of CT studies avoided by applying 'Justification' and 'Optimization' principle of ALARA were calculated. The difference in number of declined and optimized CT requests between CT requests from inpatient and outpatient departments was compared using Chi-Square test. A total of 1302 consecutive CT request forms were received during the study period. Some of the request forms (n=86; 6.61%) had requests for more than one (multiple) anatomical regions, hence, a total of 1392 different anatomical CT requests were received. Based on evaluation of the CT request forms for 'Justification' and 'Optimization' principle of ALARA by pediatric radiology reviewers, 111 individual anatomic part CT requests from 105 pediatric patients were avoided. Therefore, 8.06% (105 out of 1302 pediatric patients) were protected from unnecessary or additional radiation exposure.The rates of declined or optimized CT requests from inpatient department was significantly higher than that from outpatient

  17. The role of PET/CT in radiation treatment planning for cancer patient treatment

    International Nuclear Information System (INIS)

    2008-10-01

    Positron emission tomography (PET) and, more recently, integrated positron emission tomography/X ray computed tomography (PET/CT) have appeared as significant diagnostic imaging systems in clinical medicine. Accurate recognition of cancers in patients by means of PET scanning with Fluorine-18-fluorodeoxyglucose ( 18 F-FDG) has illustrated a need to determine a mode of therapy to achieve better prognoses. The clinical management of cancer patients has improved dramatically with the introduction of clinical PET. For treatment of cancer patients, on the other hand, radiation therapy (RT) plays an important role as a non-invasive therapy. It is crucial that cancers are encompassed by high dose irradiation, particularly in cases of curative RT. Irradiation should precisely target the entire tumour and aim to minimise the size of microscopic extensions of the cancer, as well as minimize radiation damage to normal tissues. A new imaging technique has therefore been sought to allow precise delineation of the cancer target to be irradiated. Clinical PET, combined with utilization of 18 F-FDG, may have an important role in radiation treatment planning (RTP) in lung cancer. In addition to determining if RT is appropriate and whether therapy will be given with curative or palliative intent, 18 F-FDG-PET is useful for determining therapy ports. It can be used both to limit ports to spare normal tissue and to include additional involved regions. Several studies have shown that PET has an impact on RTP in an important proportion of patients. It is to be hoped that treatment plans that include all the 18 F-FDG-avid lesions or the 18 F-FDG-avid portions of a complex mass will result in more effective local control with less unnecessary tissue being treated. The IAEA has placed emphasis on the issue of application of clinical PET for radiation treatment planning in various cancer patients. Two consultants meetings were held in 2006 and their results are summarized into this IAEA

  18. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children

    International Nuclear Information System (INIS)

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-01-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children. (orig.)

  19. Application of emission CT on nano-robot radiation imaging tracing and isotope sign in nano-robot

    International Nuclear Information System (INIS)

    Wang Xuewu; Cheng Jianping; Kang Kejun

    2000-01-01

    Nano-technology has been a scientific and technical frontier with major trends foreseen in several disciplines. Nano-robot is the most remarkable imagination of the application of nano-technology. And it should be concerned of tracing technology along with nano-robot. The character of nano-robot is deeply analyzed, the development status of emission CT is integrated, and the application of emission CT on nano-robot radiation imaging tracing is discussed. The isotope sign of nano-robot is especially calculated and analyzed

  20. Estimation of radiation dose to patients from 18 FDG whole body PET/CT investigations using dynamic PET scan protocol

    Directory of Open Access Journals (Sweden)

    Aruna Kaushik

    2015-01-01

    Full Text Available Background & objectives: There is a growing concern over the radiation exposure of patients from undergoing 18FDG PET/CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography whole body investigations. The aim of the present study was to study the kinetics of 18FDG distributions and estimate the radiation dose received by patients undergoing 18FDG whole body PET/CT investigations. Methods: Dynamic PET scans in different regions of the body were performed in 49 patients so as to measure percentage uptake of 18FDG in brain, liver, spleen, adrenals, kidneys and stomach. The residence time in these organs was calculated and radiation dose was estimated using OLINDA software. The radiation dose from the CT component was computed using the software CT-Expo and measured using computed tomography dose index (CTDI phantom and ionization chamber. As per the clinical protocol, the patients were refrained from eating and drinking for a minimum period of 4 h prior to the study. Results: The estimated residence time in males was 0.196 h (brain, 0.09 h (liver, 0.007 h (spleen, 0.0006 h (adrenals, 0.013 h (kidneys and 0.005 h (stomach whereas it was 0.189 h (brain, 0.11 h (liver, 0.01 h (spleen, 0.0007 h (adrenals, 0.02 h (kidneys and 0.004 h (stomach in females. The effective dose was found to be 0.020 mSv/MBq in males and 0.025 mSv/MBq in females from internally administered 18FDG and 6.8 mSv in males and 7.9 mSv in females from the CT component. For an administered activity of 370 MBq of 18FDG, the effective dose from PET/CT investigations was estimated to be 14.2 mSv in males and 17.2 mSv in females. Interpretation & conclusions: The present results did not demonstrate significant difference in the kinetics of 18FDG distribution in male and female patients. The estimated PET/CT doses were found to be higher than many other conventional diagnostic radiology examinations suggesting that all efforts should be made to clinically justify and

  1. Estimation of radiation dose to patients from (18) FDG whole body PET/CT investigations using dynamic PET scan protocol.

    Science.gov (United States)

    Kaushik, Aruna; Jaimini, Abhinav; Tripathi, Madhavi; D'Souza, Maria; Sharma, Rajnish; Mondal, Anupam; Mishra, Anil K; Dwarakanath, Bilikere S

    2015-12-01

    There is a growing concern over the radiation exposure of patients from undergoing 18FDG PET/CT (18F-fluorodeoxyglucose positron emission tomography/computed tomography) whole body investigations. The aim of the present study was to study the kinetics of 18FDG distributions and estimate the radiation dose received by patients undergoing 18FDG whole body PET/CT investigations. Dynamic PET scans in different regions of the body were performed in 49 patients so as to measure percentage uptake of 18FDG in brain, liver, spleen, adrenals, kidneys and stomach. The residence time in these organs was calculated and radiation dose was estimated using OLINDA software. The radiation dose from the CT component was computed using the software CT-Expo and measured using computed tomography dose index (CTDI) phantom and ionization chamber. As per the clinical protocol, the patients were refrained from eating and drinking for a minimum period of 4 h prior to the study. The estimated residence time in males was 0.196 h (brain), 0.09 h (liver), 0.007 h (spleen), 0.0006 h (adrenals), 0.013 h (kidneys) and 0.005 h (stomach) whereas it was 0.189 h (brain), 0.11 h (liver), 0.01 h (spleen), 0.0007 h (adrenals), 0.02 h (kidneys) and 0.004 h (stomach) in females. The effective dose was found to be 0.020 mSv/MBq in males and 0.025 mSv/MBq in females from internally administered 18FDG and 6.8 mSv in males and 7.9 mSv in females from the CT component. For an administered activity of 370 MBq of 18FDG, the effective dose from PET/CT investigations was estimated to be 14.2 mSv in males and 17.2 mSv in females. The present results did not demonstrate significant difference in the kinetics of 18FDG distribution in male and female patients. The estimated PET/CT doses were found to be higher than many other conventional diagnostic radiology examinations suggesting that all efforts should be made to clinically justify and carefully weigh the risk-benefit ratios prior to every 18FDG whole body PET/CT

  2. Lung and heart dose volume analyses with CT simulator in radiation treatment of breast cancer

    International Nuclear Information System (INIS)

    Das, Indra J.; Cheng, Elizabeth C.; Freedman, Gary; Fowble, Barbara

    1998-01-01

    Purpose: Radiation pneumonitis and cardiac effects are directly related to the irradiated lung and heart volumes in the treatment fields. The central lung distance (CLD) from a tangential breast radiograph is shown to be a significant indicator of ipsilateral irradiated lung volume. Retrospective analysis of the pattern of dose volume of lung and heart with actual volume data from a CT simulator in the treatment of breast cancer is presented with respect to CLD. Methods and Materials: The heart and lung volumes in the tangential treatment fields were analyzed in 108 consecutive cases (52 left and 56 right breast) referred for CT simulation. All patients in this study were immobilized and placed on an inclined breast board in actual treatment setup. Both arms were stretched over head to avoid collision with the scanner aperture. Radiopaque marks were placed on the medial and lateral borders of the tangential fields. All patients were scanned in spiral mode with slice width and thickness of 3 mm each, respectively. The lung and heart structures as well as irradiated areas were delineated on each slice and respective volumes were accurately measured. The treatment beam parameters were recorded and the digitally reconstructed radiographs (DRRs) were generated for the measurement of the CLD and analysis. Results: Using CT data the mean volume and standard deviation of left and right lungs were 1307.7 ± 297.7 cm 3 and 1529.6 ± 298.5 cm 3 , respectively. The magnitude of irradiated volume in left and right lung is nearly equal for the same CLD that produces different percent irradiated volumes (PIV). The left and right PIV lungs are 8.3 ± 4.7% and 6.6 ± 3.7%, respectively. The PIV data have shown to correlate with CLD with second- and third-degree polynomials; however, in this study a simple straight line regression is used to provide better confidence than the higher order polynomials. The regression lines for the left and right breasts are very different based on

  3. Radiation doses during chest examinations using dose modulation techniques in multislice CT scanner

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Pradip, Joe; Dinakran, Paul M.; Srikanth, B.

    2010-01-01

    Objectives: To evaluate the radiation dose and image quality using a manual protocol and dose modulation techniques in a 6-slice CT scanner. Materials and Methods: Two hundred and twenty-one patients who underwent contrast-enhanced CT of the chest were included in the study. For the manual protocol settings, constant tube potential (kV) and tube current-time product (mAs) of 140 kV and 120 mAs, respectively, were used. The angular and z-axis dose modulation techniques utilized a constant tube potential of 140 kV; mAs values were automatically selected by the machine. Effective doses were calculated using dose-length product (DLP) values and the image quality was assessed using the signal-to-noise (SNR) ratio values. Mean effective doses using manual protocol for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 8.58 mSv, 8.54 mSv, and 9.07 mSv, respectively. Mean effective doses using z-axis dose modulation for patients of weights 40-60 kg, 61-80 kg, and 81 kg and above were 4.95 mSv, 6.87 mSv, and 10.24 mSv, respectively. The SNR at the region of the liver for patients of body weight of 40-60 kg was 5.1 H, 6.2 H, and 8.8 H for manual, angular, and z-axis dose modulation, respectively. Conclusion: Dose reduction of up to 15% was achieved using angular dose modulation and of up to 42% using z-axis dose modulation, with acceptable diagnostic image quality compared to the manual protocol. (author)

  4. Reduction in radiation dose with reconstruction technique in the brain perfusion CT

    Science.gov (United States)

    Kim, H. J.; Lee, H. K.; Song, H.; Ju, M. S.; Dong, K. R.; Chung, W. K.; Cho, M. S.; Cho, J. H.

    2011-12-01

    The principal objective of this study was to verify the utility of the reconstruction imaging technique in the brain perfusion computed tomography (PCT) scan by assessing reductions in the radiation dose and analyzing the generated images. The setting used for image acquisition had a detector coverage of 40 mm, a helical thickness of 0.625 mm, a helical shuttle mode scan type and a rotation time of 0.5 s as the image parameters used for the brain PCT scan. Additionally, a phantom experiment and an animal experiment were carried out. In the phantom and animal experiments, noise was measured in the scanning with the tube voltage fixed at 80 kVp (kilovolt peak) and the level of the adaptive statistical iterative reconstruction (ASIR) was changed from 0% to 100% at 10% intervals. The standard deviation of the CT coefficient was measured three times to calculate the mean value. In the phantom and animal experiments, the absorbed dose was measured 10 times under the same conditions as the ones for noise measurement before the mean value was calculated. In the animal experiment, pencil-type and CT-dedicated ionization chambers were inserted into the central portion of pig heads for measurement. In the phantom study, as the level of the ASIR changed from 0% to 100% under identical scanning conditions, the noise value and dose were proportionally reduced. In our animal experiment, the noise value was lowest when the ASIR level was 50%, unlike in the phantom study. The dose was reduced as in the phantom study.

  5. Performance of CT ASPECTS and Collateral Score in Risk Stratification: Can Target Perfusion Profiles Be Predicted without Perfusion Imaging?

    Science.gov (United States)

    Dehkharghani, S; Bammer, R; Straka, M; Bowen, M; Allen, J W; Rangaraju, S; Kang, J; Gleason, T; Brasher, C; Nahab, F

    2016-08-01

    Endovascular trials suggest that revascularization benefits a subset of acute ischemic stroke patients with large-artery occlusion and small-core infarct volumes. The objective of our study was to identify thresholds of noncontrast CT-ASPECTS and collateral scores on CT angiography that best predict ischemic core volume thresholds quantified by CT perfusion among patients with acute ischemic stroke. Fifty-four patients with acute ischemic stroke (collateral score of 3 had 100% specificity for identifying patients with a CBF core volume of ≤50 mL. NCCT-ASPECTS of ≤6 had 100% specificity for identifying patients with a CBF core volume of >50 mL. In our cohort, 44 (81%) patients had an NCCT-ASPECTS of ≥9, a CTA collateral score of 3, or an NCCT-ASPECTS of ≤6. Using an NCCT-ASPECTS of ≥9 or a CTA collateral score of 3 best predicts CBF core volume infarct of ≤50 mL, while an NCCT-ASPECTS of ≤6 best predicts a CBF core volume infarct of >50 mL. Together these thresholds suggest that a specific population of patients with acute ischemic stroke not meeting such profiles may benefit most from CTP imaging to determine candidacy for revascularization. © 2016 by American Journal of Neuroradiology.

  6. MicroRNA Expression Profiling Altered by Variant Dosage of Radiation Exposure

    Directory of Open Access Journals (Sweden)

    Kuei-Fang Lee

    2014-01-01

    Full Text Available Various biological effects are associated with radiation exposure. Irradiated cells may elevate the risk for genetic instability, mutation, and cancer under low levels of radiation exposure, in addition to being able to extend the postradiation side effects in normal tissues. Radiation-induced bystander effect (RIBE is the focus of rigorous research as it may promote the development of cancer even at low radiation doses. Alterations in the DNA sequence could not explain these biological effects of radiation and it is thought that epigenetics factors may be involved. Indeed, some microRNAs (or miRNAs have been found to correlate radiation-induced damages and may be potential biomarkers for the various biological effects caused by different levels of radiation exposure. However, the regulatory role that miRNA plays in this aspect remains elusive. In this study, we profiled the expression changes in miRNA under fractionated radiation exposure in human peripheral blood mononuclear cells. By utilizing publicly available microRNA knowledge bases and performing cross validations with our previous gene expression profiling under the same radiation condition, we identified various miRNA-gene interactions specific to different doses of radiation treatment, providing new insights for the molecular underpinnings of radiation injury.

  7. WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

    International Nuclear Information System (INIS)

    Molloi, S; Li, B; Yin, F; Chen, H

    2014-01-01

    classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application

  8. Knowledge of Radiation Hazards, Radiation Protection Practices and Clinical Profile of Health Workers in a Teaching Hospital in Northern Nigeria.

    Science.gov (United States)

    Awosan, K J; Ibrahim, Mto; Saidu, S A; Ma'aji, S M; Danfulani, M; Yunusa, E U; Ikhuenbor, D B; Ige, T A

    2016-08-01

    Use of ionizing radiation in medical imaging for diagnostic and interventional purposes has risen dramatically in recent years with a concomitant increase in exposure of patients and health workers to radiation hazards. To assess the knowledge of radiation hazards, radiation protection practices and clinical profile of health workers in UDUTH, Sokoto, Nigeria. A cross-sectional study was conducted among 110 Radiology, Radiotherapy and Dentistry staff selected by universal sampling technique. The study comprised of administration of standardized semi-structured pre-tested questionnaire (to obtain information on socio-demographic characteristics, knowledge of radiation hazards, and radiation protection practices of participants), clinical assessment (comprising of chest X-ray, abdominal ultrasound and laboratory investigation on hematological parameters), and evaluation of radiation exposure of participants (extracted from existing hospital records on their radiation exposure status). The participants were aged 20 to 65 years (mean = 34.04 ± 8.83), most of them were males (67.3%) and married (65.7%). Sixty five (59.1%) had good knowledge of radiation hazards, 58 (52.7%) had good knowledge of Personal Protective Devices (PPDs), less than a third, 30 (27.3%) consistently wore dosimeter, and very few (10.9% and below) consistently wore the various PPDs at work. The average annual radiation exposure over a 4 year period ranged from 0.0475mSv to 1.8725mSv. Only 1 (1.2%) of 86 participants had abnormal chest X-ray findings, 8 (9.4%) of 85 participants had abnormal abdominal ultrasound findings; while 17 (15.5%) and 11 (10.0%) of 110 participants had anemia and leucopenia respectively. This study demonstrated poor radiation protection practices despite good knowledge of radiation hazards among the participants, but radiation exposure and prevalence of abnormal clinical conditions were found to be low. Periodic in-service training and monitoring on radiation safety was

  9. Dose profile study in head CT scans using a male anthropomorphic phantom

    International Nuclear Information System (INIS)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P.

    2017-01-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  10. Dose profile study in head CT scans using a male anthropomorphic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, Alvaro M.L.; Santana, Priscila do C.; Mourao, Arnaldo P., E-mail: amlgphys@gmail.com, E-mail: pridili@gmail.com, E-mail: apratabhz@gmail.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Computed tomography (CT) test is an efficient and non-invasive method to obtain data about internal structures of the human body. CT scans contribute with the highest absorbed doses in population due X-ray beam attenuation and it has raised concern in radiosensitive tissues. Techniques for the optimization of CT scanning protocols in diagnostic services have been developing with the objective of decreasing the absorbed dose in the patient, aiming image quality within acceptable parameters for diagnosis by noise control. Routine head scans were performed using GE CT scan of 64 channels programmed with automatic exposure control and voltages of 80, 100 and 120 kV attaching the noise index in approximately 0.5%, using the tool of smart mA. An anthropomorphic adult male phantom was used and radiochromic film strips were placed to measure the absorbed dose deposited in areas such as the lens, thyroid and pituitary for study of dose deposited in these important areas containing high radiosensitive tissues. Different head scans were performed using optimized values of mA.s for the different voltages. The absorbed dose measured by the film strips were in the range of the 0.58 and 44.36 mGy. The analysis of noise in the images is within the acceptable levels for diagnosis, and the optimized protocol happens with the voltage of 100 kV. The use of other voltage values can allow obtain better protocols for head scans. (author)

  11. Characterization of radiation qualities used for the determination of characteristic in CT application according to IEC 61267:2005

    International Nuclear Information System (INIS)

    Dias, Daniel M.; Silva Junior, Iremar A. da; Potiens, Maria da Penha A.

    2009-01-01

    The purpose of this study was to establish the standard RQT radiation qualities which represent simulations of the unattenuated beam used in Computed Tomography (CT). Thus, to avoiding excessive efforts for establishing a radiation quality by means of the spectral distribution of the photon fluence, the characterization of these standard radiation qualities was expressed in terms of the X-ray tube voltage, first and second half-value layer (HVL). To establishing the standard radiation beam, according to the IEC 61267 and the TRS 457 was measured first of all the correct values of the X ray tube voltages in terms of Practical Peak Voltage. The standard radiation qualities RQT were produced using the same set up mounted for the RQR qualities which had been early established, and for simulating the patient in order to achieve the standard RQT series, suitable thicknesses of layers of copper were used to obtain the values of the first HVL according to IEC 61267. (author)

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging ...

  13. Potential impact of 68Ga-PSMA-11 PET/CT on prostate cancer definitive radiation therapy planning.

    Science.gov (United States)

    Calais, Jérémie; Kishan, Amar U; Cao, Minsong; Fendler, Wolfgang P; Eiber, Matthias; Herrmann, Ken; Ceci, Francesco; Reiter, Robert E; Matthew, Rettig B; Hegde, John V; Shaverdian, Narek; King, Christopher R; Steinberg, Michael L; Czernin, Johannes; Nickols, Nicholas G

    2018-04-13

    Background: Standard-of-care imaging for initial staging of prostate cancer (PCa) underestimates disease burden. Prostate specific membrane antigen (PSMA) positron emission tomography/ computed tomography (PET/CT) detects PCa metastasis with superior accuracy with potential impact definitive radiation therapy (RT) planning for non-metastatic PCa. Objectives: i) To determine how often definitive PCa RT planning based on standard target volumes cover 68 Ga-PSMA-11 PET/CT defined disease, and ii) To assess the potential impact of 68 Ga-PSMA-11 PET/CT on definitive PCa RT planning. Patients and Methods: This is a post-hoc analysis of an intention to treat population of 73 patients with localized PCa without prior local therapy who underwent 68 Ga-PSMA PET/CT for initial staging as part of an Investigational New Drug trial. 11/73 were intermediate-risk (15%), 33/73 were high-risk (45%), 22/73 were very high risk (30%), and 7/73 were N1 (9.5%). Clinical target volumes (CTVs) that included the prostate, seminal vesicles, and pelvic lymph nodes (LNs) using Radiation Therapy Oncology Group (RTOG) consensus guidelines were contoured on the CT portion of the PET/CT by a radiation oncologist blinded to the PET findings. 68 Ga-PSMA-11 PET/CT images were analyzed by a nuclear medicine physician. PSMA-positive lesions not covered by planning volumes based on the CTVs were considered to have a major potential impact on treatment planning. Results: All patients had PSMA-positive primary prostate lesion(s). 25/73 (34%) and 7/73 (9.5%) had PSMA-positive pelvic nodal and distant metastases, respectively. The sites of nodal metastases in decreasing order of frequency were external iliac (20.5%), common iliac (13.5%), internal iliac (12.5%) obturator (12.5%), perirectal (4%), abdominal (4%), upper-diaphragm (4%), and presacral (1.5%). The median size of the nodal lesions was 6 mm (range 4-24 mm). RT planning based on the CTVs covered 69/73 (94.5%) of primary disease and 20/25 (80%) of

  14. Radiation-associated breast tumors display a distinct gene expression profile

    DEFF Research Database (Denmark)

    Broeks, Annegien; Braaf, Linde M; Wessels, Lodewyk F A

    2010-01-01

    PURPOSE: Women who received irradiation for Hodgkin's lymphoma have a strong increased risk for developing breast cancer. Approximately 90% of the breast cancers in these patients can be attributed to their radiation treatment, rendering such series extremely useful to determine whether a common...... radiation-associated cause underlies the carcinogenic process. METHODS AND MATERIALS: In this study we used gene expression profiling technology to assess gene expression changes in radiation-associated breast tumors compared with a set of control breast tumors of women unexposed to radiation, diagnosed...... at the same age. RNA was obtained from fresh frozen tissue samples from 22 patients who developed breast cancer after Hodgkin's lymphoma (BfHL) and from 20 control breast tumors. RESULTS: Unsupervised hierarchical clustering of the profile data resulted in a clustering of the radiation-associated tumors...

  15. Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT

    Science.gov (United States)

    Dillman, Jonathan R.; Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Keshavarzi, Nahid; Strouse, Peter J.

    2014-01-01

    Purpose To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection. Materials and Methods Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified. Images were reconstructed with two algorithms: MBIR and 100% ASIR. All subjects had undergone standard-dose CT within the prior year, and the images were reconstructed with 30% ASIR. Reduced- and standard-dose images were evaluated objectively and subjectively. Reduced-dose images were evaluated for lesion detectability. Spatial resolution was assessed in a phantom. Radiation dose was estimated by using volumetric CT dose index (CTDIvol) and calculated size-specific dose estimates (SSDE). A combination of descriptive statistics, analysis of variance, and t tests was used for statistical analysis. Results In the 25 patients who underwent the reduced-dose protocol, mean decrease in CTDIvol was 46% (range, 19%–65%) and mean decrease in SSDE was 44% (range, 19%–64%). Reduced-dose MBIR images had less noise (P > .004). Spatial resolution was superior for reduced-dose MBIR images. Reduced-dose MBIR images were equivalent to standard-dose images for lungs and soft tissues (P > .05) but were inferior for bones (P = .004). Reduced-dose 100% ASIR images were inferior for soft tissues (P ASIR. Conclusion CT performed with a reduced-dose protocol and MBIR is feasible in the pediatric population, and it maintains diagnostic quality. © RSNA, 2013 Online supplemental material is available for this article. PMID:24091359

  16. Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI

    DEFF Research Database (Denmark)

    Zimmermann, S. J.; Rowshanfarzad, P.; Ebert, M. A.

    2015-01-01

    ) and the radiation field centre (RFC) is calculated. A software package was developed for accurate calculation of the linac isocentre position. This requires precise determination of the position of the ball bearing and the RFC. Results: Data were acquired for 6 MV, 18 MV and flattening filter free (FFF) 6 MV FFF...... radiation isocentre prior to routine use of the cone-beam CT system. The isocentre determination method used in the XVI software is not available to users. The aim of this work is to perform an independent evaluation of the Elekta XVI 4.5 software for isocentre verification with focus on the robustness...... iView GT software. Two images were acquired at each cardinal gantry angle (-180o, -90o , 0o, 90o) at two opposing collimator angles. The images were exported to the conebeam CT software XVI 4.5 where the difference between the ball bearing position in the XYZ-room coordinates (IEC61217...

  17. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

    International Nuclear Information System (INIS)

    Desai, Gaurav S.; Uppot, Raul N.; Kambadakone, Avinash R.; Yu, Elaine W.; Sahani, Dushyant V.

    2012-01-01

    To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing ≥91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing ≥91 kg (mean body weight: 107.6 ± 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 ± 0.5 vs. 1.6 ± 0.6, P < 0.05) and objective noise (13.0 ± 3.2 vs.19.5 ± 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 ± 7.3 mGy; FBP: 19.7 ± 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. circle CT images in obese adults are noisy, even with high radiation dose. (orig.)

  18. Impact of iterative reconstruction on image quality and radiation dose in multidetector CT of large body size adults

    Energy Technology Data Exchange (ETDEWEB)

    Desai, Gaurav S.; Uppot, Raul N.; Kambadakone, Avinash R. [Harvard Medical School, Department of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States); Yu, Elaine W. [Harvard Medical School, Massachusetts General Hospital, Boston, MA (United States); Sahani, Dushyant V. [Harvard Medical School, Department of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Department of Radiology, Division of Abdominal Imaging and Intervention, Massachusetts General Hospital, Boston, MA (United States)

    2012-08-15

    To compare image quality and radiation dose using Adaptive Statistical Iterative Reconstruction (ASiR) and Filtered Back Projection (FBP) in patients weighing {>=}91 kg. In this Institution Review Board-approved retrospective study, single-phase contrast-enhanced abdominopelvic CT examinations of 100 adults weighing {>=}91 kg (mean body weight: 107.6 {+-} 17.4 kg range: 91-181.9 kg) with (1) ASiR and (2) FBP were reviewed by two readers in a blinded fashion for subjective measures of image quality (using a subjective standardized numerical scale and objective noise) and for radiation exposure. Imaging parameters and radiation dose results of the two techniques were compared within weight and BMI sub-categories. All examinations were found to be of adequate quality. Both subjective (mean = 1.4 {+-} 0.5 vs. 1.6 {+-} 0.6, P < 0.05) and objective noise (13.0 {+-} 3.2 vs.19.5 {+-} 5.7, P < 0.0001) were lower with ASiR. Average radiation dose reduction of 31.5 % was achieved using ASiR (mean CTDIvol. ASiR: 13.5 {+-} 7.3 mGy; FBP: 19.7 {+-} 9.0 mGy, P < 0.0001). Other measures of image quality were comparable between the two techniques. Trends for all parameters were similar in patients across weight and BMI sub-categories. In obese individuals, abdominal CT images reconstructed using ASiR provide diagnostic images with reduced image noise at lower radiation dose. circle CT images in obese adults are noisy, even with high radiation dose. (orig.)

  19. Assessing the Dosimetric Accuracy of Magnetic Resonance-Generated Synthetic CT Images for Focal Brain VMAT Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Paradis, Eric, E-mail: eparadis@umich.edu [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Cao, Yue [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Radiology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Department of Biomedical Engineering, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States); Lawrence, Theodore S.; Tsien, Christina; Feng, Mary; Vineberg, Karen; Balter, James M. [Department of Radiation Oncology, University of Michigan Hospital and Health Systems, Ann Arbor, Michigan (United States)

    2015-12-01

    Purpose: The purpose of this study was to assess the dosimetric accuracy of synthetic CT (MRCT) volumes generated from magnetic resonance imaging (MRI) data for focal brain radiation therapy. Methods and Materials: A study was conducted in 12 patients with gliomas who underwent both MR and CT imaging as part of their simulation for external beam treatment planning. MRCT volumes were generated from MR images. Patients' clinical treatment planning directives were used to create 12 individual volumetric modulated arc therapy (VMAT) plans, which were then optimized 10 times on each of their respective CT and MRCT-derived electron density maps. Dose metrics derived from optimization criteria, as well as monitor units and gamma analyses, were evaluated to quantify differences between the imaging modalities. Results: Mean differences between planning target volume (PTV) doses on MRCT and CT plans across all patients were 0.0% (range: −0.1 to 0.2%) for D{sub 95%}; 0.0% (−0.7 to 0.6%) for D{sub 5%}; and −0.2% (−1.0 to 0.2%) for D{sub max}. MRCT plans showed no significant changes in monitor units (−0.4%) compared to CT plans. Organs at risk (OARs) had average D{sub max} differences of 0.0 Gy (−2.2 to 1.9 Gy) over 85 structures across all 12 patients, with no significant differences when calculated doses approached planning constraints. Conclusions: Focal brain VMAT plans optimized on MRCT images show excellent dosimetric agreement with standard CT-optimized plans. PTVs show equivalent coverage, and OARs do not show any overdose. These results indicate that MRI-derived synthetic CT volumes can be used to support treatment planning of most patients treated for intracranial lesions.

  20. Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI

    DEFF Research Database (Denmark)

    Lynggaard Riis, Hans; Moltke, Lars N; Zimmermann, S. J.

    2016-01-01

    Accurate determination of the megavoltage (MV) radiation isocentre of a linear accelerator (linac) is an important task in radiotherapy. The localization of the MV radiation isocentre is crucial for correct calibration of the in-room lasers and the cone-beam CT scanner used for patient positioning...... orientation or the phantom asymmetry in the longitudinal direction do not appear to cause the discrepancy. The main cause of the differences could not be clearly identified. However, it is our opinion that the commercial software delivered by the linac manufacturer should be improved to reach better stability...

  1. Collimator optimization for small animal radiation therapy at a micro-CT

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Manuela C. [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Glatting, Gerhard [Heidelberg Univ., Mannheim (Germany). Medical Radiation Physics/Radiation Protection; Giordano, Frank A.; Wenz, Frederik; Fleckenstein, Jens [Heidelberg Univ., Mannheim (Germany). Dept. of Radiation Oncology; Brockmann, Marc A. [Heidelberg Univ., Mannheim (Germany). Dept. of Neuroradiology; University Medical Center Mainz (Germany). Dept. of Neuroradiology

    2017-05-01

    In radiation therapy of small animals treatment depths range from a few millimetres to several centimetres. In order to spare surrounding organs at risk steep dose gradients are necessary. To minimize the treatment time, and therefore the strain to the animals, a high dose rate is required. A description how these parameters can be optimized through an appropriate choice of collimators with different source surface distances (SSD) as well as different materials and geometries is presented. An industrial micro-CT unit (Y.Fox, YXLON GmbH, Hamburg, Germany) was converted into a precision irradiator for small animals. Different collimators of either stainless steel (Fe) with cylindrical bores (SSD = 42 mm) or tungsten (W) with conical bores (SSD = 14 mm) were evaluated. The dosimetry of very small radiation fields presents a challenge and was performed with GafChromic EBT3 films (Ashland, Vayne, KY, USA) in a water phantom. The films were calibrated with an ionization chamber in the uncollimated field. Treatments were performed via a rotation of the objects with a fixed radiation source. As expected, the shorter SSD of the W-collimators resulted in a (4.5 ± 1.6)-fold increase of the dose rates compared to the corresponding Fe-collimators. The ratios of the dose rates at 1 mm and 10 mm depth in the water phantom was (2.6 ± 0.2) for the Fe- and (4.5 ± 0.1) for the W-collimators. For rotational treatments in a cylindrical plastic phantom maximum dose rates of up to 1.2 Gy/min for Fe- and 5.1 Gy/min for W-collimators were measured. Choosing the smallest possible SSD leads to a high dose rate and a high surface dose, which is of advantage for the treatment of superficial target volumes. For larger SSD the dose rate is lower and the depth dose curve is shallower. This leads to a reduction of the surface dose and is best suited for treatments of deeper seated target volumes. Divergent collimator bores have, due to the reduced scatter within the collimators, a steeper

  2. Image Quality of 3rd Generation Spiral Cranial Dual-Source CT in Combination with an Advanced Model Iterative Reconstruction Technique: A Prospective Intra-Individual Comparison Study to Standard Sequential Cranial CT Using Identical Radiation Dose.

    Science.gov (United States)

    Wenz, Holger; Maros, Máté E; Meyer, Mathias; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O; Flohr, Thomas; Leidecker, Christianne; Groden, Christoph; Scharf, Johann; Henzler, Thomas

    2015-01-01

    To prospectively intra-individually compare image quality of a 3rd generation Dual-Source-CT (DSCT) spiral cranial CT (cCT) to a sequential 4-slice Multi-Slice-CT (MSCT) while maintaining identical intra-individual radiation dose levels. 35 patients, who had a non-contrast enhanced sequential cCT examination on a 4-slice MDCT within the past 12 months, underwent a spiral cCT scan on a 3rd generation DSCT. CTDIvol identical to initial 4-slice MDCT was applied. Data was reconstructed using filtered backward projection (FBP) and 3rd-generation iterative reconstruction (IR) algorithm at 5 different IR strength levels. Two neuroradiologists independently evaluated subjective image quality using a 4-point Likert-scale and objective image quality was assessed in white matter and nucleus caudatus with signal-to-noise ratios (SNR) being subsequently calculated. Subjective image quality of all spiral cCT datasets was rated significantly higher compared to the 4-slice MDCT sequential acquisitions (pspiral compared to sequential cCT datasets with mean SNR improvement of 61.65% (p*Bonferroni0.05spiral cCT with an advanced model IR technique significantly improves subjective and objective image quality compared to a standard sequential cCT acquisition acquired at identical dose levels.

  3. Definition of the supraclavicular and infraclavicular nodes: implications for three-dimensional CT-based conformal radiation therapy.

    Science.gov (United States)

    Madu, C N; Quint, D J; Normolle, D P; Marsh, R B; Wang, E Y; Pierce, L J

    2001-11-01

    To delineate with computed tomography (CT) the anatomic regions containing the supraclavicular (SCV) and infraclavicular (IFV) nodal groups, to define the course of the brachial plexus, to estimate the actual radiation dose received by these regions in a series of patients treated in the traditional manner, and to compare these doses to those received with an optimized dosimetric technique. Twenty patients underwent contrast material-enhanced CT for the purpose of radiation therapy planning. CT scans were used to study the location of the SCV and IFV nodal regions by using outlining of readily identifiable anatomic structures that define the nodal groups. The brachial plexus was also outlined by using similar methods. Radiation therapy doses to the SCV and IFV were then estimated by using traditional dose calculations and optimized planning. A repeated measures analysis of covariance was used to compare the SCV and IFV depths and to compare the doses achieved with the traditional and optimized methods. Coverage by the 90% isodose surface was significantly decreased with traditional planning versus conformal planning as the depth to the SCV nodes increased (P correlation was found between brachial plexus depth and SCV depth up to 7 cm. Conformal optimized planning provided improved dosimetric coverage compared with standard techniques.

  4. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zuerich (Switzerland); Dietrich, Tobias J. [Balgrist University Hospital, Department of Radiology, Zurich (Switzerland); Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo [Siemens Healthcare GmbH, Business Area Advanced Therapies, Forchheim (Germany); Le Corroller, Thomas [Aix-Marseille Universite, CNRS, ISM UMR 7287, Marseille (France); Radiology Department, APHM, Marseille (France)

    2017-02-15

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  5. C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance

    International Nuclear Information System (INIS)

    Guggenberger, Roman; Ulbrich, Erika J.; Kaelin, Pascal; Pfammatter, Thomas; Alkadhi, Hatem; Andreisek, Gustav; Dietrich, Tobias J.; Scholz, Rosemarie; Koehler, Christoph; Elsaesser, Thilo; Le Corroller, Thomas

    2017-01-01

    To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between κ = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. (orig.)

  6. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O'Connell, Avice M; Conover, David L

    2013-01-01

    diagnostic mammography, the median MGD from dedicated breast CT was approximately 13.5% higher than that from diagnostic mammography. The MGD for breast CT is based on a 1.45 mm skin layer and that for diagnostic mammography is based on a 4 mm skin layer; thus, favoring a lower estimate for MGD from diagnostic mammography. The median MGD from dedicated breast CT corresponds to the median MGD from four to five diagnostic mammography views. In comparison, for the same 133 breasts, the mean and the median number of views per breast during diagnostic mammography were 4.53 and 4, respectively. Paired analysis showed that there was approximately equal likelihood of receiving lower MGD from either breast CT or diagnostic mammography. Future work will investigate methods to reduce and optimize radiation dose from dedicated breast CT. (paper)

  7. SU-F-T-403: Impact of Dose Reduction for Simulation CT On Radiation Therapy Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Q; Shah, P; Li, S; Miyamoto, C [Temple University Hospital, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To investigate the feasibility of applying ALARA principles to current treatment planning CT scans. The study aims to quantitatively verify lower dose scans does not alter treatment planning. Method: Gammex 467 tissue characterization phantom with inserts of 14 different materials was scanned at seven different mA levels (30∼300 mA). CT numbers of different inserts were measured. Auto contouring for bone and lung in treatment planning system (Pinnacle) was used to evaluate the effect of CT number accuracy from treatment planning aspect, on the 30 and 300 mA-scanned images. A head CT scan intended for a 3D whole brain radiation treatment was evaluated. Dose calculations were performed on normal scanned images using clinical protocol (120 kVP, Smart mA, maximum 291 mA), and the images with added simulating noise mimicking a 70 mA scan. Plan parameters including isocenter, beam arrangements, block shapes, dose grid size and resolution, and prescriptions were kept the same for these two plans. The calculated monitor units (MUs) for these two plans were compared. Results: No significant degradation of CT number accuracy was found at lower dose levels from both the phantom scans, and the patient images with added noise. The CT numbers kept consistent when mA is higher than 60 mA. The auto contoured volumes for lung and cortical bone show 0.3% and 0.12% of differences between 30 mA and 300 mA respectively. The two forward plans created on regular and low dose images gave the same calculated MU, and 98.3% of points having <1% of dose difference. Conclusion: Both phantom and patient studies quantitatively verified low dose CT provides similar quality for treatment planning at 20–25% of regular scan dose. Therefore, there is the potential to optimize simulation CT scan protocol to fulfil the ALARA principle and limit unnecessary radiation exposure to non-targeted tissues.

  8. Pediatric CT: implementation of ASIR for substantial radiation dose reduction while maintaining pre-ASIR image noise.

    Science.gov (United States)

    Brady, Samuel L; Moore, Bria M; Yee, Brian S; Kaufman, Robert A

    2014-01-01

    To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current-modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose reduction tool only; no net change to the magnitude

  9. Pediatric cT: Implementation of ASIR for Substantial Radiation Dose Reduction While Maintaining Pre-ASIR Image Noise1

    Science.gov (United States)

    Brady, Samuel L.; Moore, Bria M.; Yee, Brian S.; Kaufman, Robert A.

    2015-01-01

    Purpose To determine a comprehensive method for the implementation of adaptive statistical iterative reconstruction (ASIR) for maximal radiation dose reduction in pediatric computed tomography (CT) without changing the magnitude of noise in the reconstructed image or the contrast-to-noise ratio (CNR) in the patient. Materials and Methods The institutional review board waived the need to obtain informed consent for this HIPAA-compliant quality analysis. Chest and abdominopelvic CT images obtained before ASIR implementation (183 patient examinations; mean patient age, 8.8 years ± 6.2 [standard deviation]; range, 1 month to 27 years) were analyzed for image noise and CNR. These measurements were used in conjunction with noise models derived from anthropomorphic phantoms to establish new beam current–modulated CT parameters to implement 40% ASIR at 120 and 100 kVp without changing noise texture or magnitude. Image noise was assessed in images obtained after ASIR implementation (492 patient examinations; mean patient age, 7.6 years ± 5.4; range, 2 months to 28 years) the same way it was assessed in the pre-ASIR analysis. Dose reduction was determined by comparing size-specific dose estimates in the pre- and post-ASIR patient cohorts. Data were analyzed with paired t tests. Results With 40% ASIR implementation, the average relative dose reduction for chest CT was 39% (2.7/4.4 mGy), with a maximum reduction of 72% (5.3/18.8 mGy). The average relative dose reduction for abdominopelvic CT was 29% (4.8/6.8 mGy), with a maximum reduction of 64% (7.6/20.9 mGy). Beam current modulation was unnecessary for patients weighing 40 kg or less. The difference between 0% and 40% ASIR noise magnitude was less than 1 HU, with statistically nonsignificant increases in patient CNR at 100 kVp of 8% (15.3/14.2; P = .41) for chest CT and 13% (7.8/6.8; P = .40) for abdominopelvic CT. Conclusion Radiation dose reduction at pediatric CT was achieved when 40% ASIR was implemented as a dose

  10. SU-E-I-31: Differences Observed in Radiation Doses Across 2 Similar CT Scanners From Adult Brain-Neck CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, K [Graduate School of Medicine, Nagoya University, Nagoya, JP (Japan); UCLA School of Medicine, Los Angeles, CA (United States); McMillan, K; Bostani, M; Cagnon, C; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: The aim of this study is to evaluate the difference in radiation doses from adult Brain-Neck CT angiography (CTA) between two CT scanners. Methods: We collected CT dose index data (CTDIvol, DLP) from adult Brain-Neck CTA performed with two CT scanners (Sensation 64 (S64) and Definition AS (AS), Siemens Healthcare) performed at two of our facilities from Jan 1st to Dec 31th, 2014. X-ray dose management software (Radmetrics, Bayer Healthcare) was used to mine these data. All exams were performed with Tube Current Modulation (Care Dose 4D), tube voltage of 120 kVp, quality reference mAs of 300, beam collimation of 64*0.6 mm. The rotation time was set to 0.5 sec for S64 and 1.0 sec for AS. We also scanned an anthropomorphic skull and chest phantom under routine Brain-Neck CTA protocol with the two scanners and extracted the tube current values from the raw projection data. Results: The mean CTDIvol and DLP in Brain-Neck CTA was 72 mGy and 2554 mGy*cm for AS, which was substantially larger than the mean values of 46 mGy and 1699 mGy*cm for S64. The maximum tube current was 583 mA for most cases on the S64 while the maximum was 666 mA for AS even though the rotation time set for AS was 1.0 sec. Measurements obtained with the anthropomorphic phantom showed that the tube current reached 583 mA at the shoulder region for S64 while it reached to 666 mA for AS. Conclusion: The results of this study showed that substantially different CT doses can Result from Brain-Neck CTA protocols even when similar scanners and similar settings are used. Though both scanners have a similar maximum mA rating, differences in mA were observed through the shoulders, resulting in substantially different CTDIvol values.

  11. Automated extraction of radiation dose information from CT dose report images.

    Science.gov (United States)

    Li, Xinhua; Zhang, Da; Liu, Bob

    2011-06-01

    The purpose of this article is to describe the development of an automated tool for retrieving texts from CT dose report images. Optical character recognition was adopted to perform text recognitions of CT dose report images. The developed tool is able to automate the process of analyzing multiple CT examinations, including text recognition, parsing, error correction, and exporting data to spreadsheets. The results were precise for total dose-length product (DLP) and were about 95% accurate for CT dose index and DLP of scanned series.

  12. Preliminary studies into profiling DNA recovered from a radiation or radioactivity incident

    International Nuclear Information System (INIS)

    Hodgson, A.; Baxter, A.

    2013-01-01

    The examination and profiling of human DNA recovered from a scene of crime is an essential aspect of criminal investigations. However, it is currently not known whether DNA recovered from a scene where an ionising radiation source or radioactive contamination is present can be successfully profiled. The direct examination and analysis of radioactively contaminated DNA has not been widely explored using the current procedures employed by forensic service providers. As a result, AWE is putting in place an extensive research and development programme to better understand the effects that radiation has on the ability to profile human DNA, and assess the associated retention of different radioactive contaminants within each step of the profiling procedure. A summary will be provided on the aims of this project and progress that has been made to date; together with a discussion of the lessons that have been learnt during the course of the programme's development. (author)

  13. Effects of Rubber Loading on the Ultrasonic Backward Radiation Profile of Leaky Lamb Wave

    International Nuclear Information System (INIS)

    Song, Sung Jin; Jung, Min Ho; Kim, Young H.; Kwon, Sung Duk

    2002-01-01

    The characterization of adhesive property in multi-layer materials has been hot issue for a long time. In order to evaluate adhesive properties, we constructed fully automated system for the backward radiation of leaky Lamb wave. The backward radiation profiles were obtained for the bare steel plate and plates with rubber-loading. The rf waveforms and frequency spectra of backward radiation show the characteristics of involved leaky Lamb wave modes. As the thickness of rubber-loading increased, the amplitude of profile at the incident angle of 13.4' exponentially decreased. Scanning the incident position over the partially rubber-loaded specimen shows good agreement with the actual rubber-loading. The backward radiation of leaky Lamb wave has great potential to evaluate the adhesive condition as well as material properties of plates

  14. Relationship between line spread function (LSF), or slice sensitivity profile (SSP), and point spread function (PSF) in CT image system

    International Nuclear Information System (INIS)

    Ohkubo, Masaki; Wada, Shinichi; Kobayashi, Teiji; Lee, Yongbum; Tsai, Du-Yih

    2004-01-01

    In the CT image system, we revealed the relationship between line spread function (LSF), or slice sensitivity profile (SSP), and point spread function (PSF). In the system, the following equation has been reported; I(x,y)=O(x,y) ** PSF(x,y), in which I(x,y) and O(x,y) are CT image and object function, respectively, and ** is 2-dimensional convolution. In the same way, the following 3-dimensional expression applies; I'(x,y,z)=O'(x,y,z) *** PSF'(x,y,z), in which z-axis is the direction perpendicular to the x/y-scan plane. We defined that the CT image system was separable, when the above two equations could be transformed into following equations; I(x,y)=[O(x,y) * LSF x (x)] * LSF y (y) and I'(x,y,z) =[O'(x,y,z) * SSP(z)] ** PSF(x,y), respectively, in which LSF x (x) and LSF y (y) are LSFs in x- and y-direction, respectively. Previous reports for the LSF and SSP are considered to assume the separable-system. Under the condition of separable-system, we derived following equations; PSF(x,y)=LSF x (x) ·LSF y (y) and PSF'(x,y,z)=PSF(x,y)·SSP(z). They were validated by the computer-simulations. When the study based on 1-dimensional functions of LSF and SSP are expanded to that based on 2- or 3-dimensional functions of PSF, derived equations must be required. (author)

  15. Is Weight-Based Adjustment of Automatic Exposure Control Necessary for the Reduction of Chest CT Radiation Dose?

    Science.gov (United States)

    Prakash, Priyanka; Gilman, Matthew D.; Shepard, Jo-Anne O.; Digumarthy, Subba R.

    2010-01-01

    Objective To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. Materials and Methods With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Results Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). Conclusion The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. PMID:20046494

  16. Radiation exposure to nuclear medicine staffs during 18F-FDG PET/CT procedures at Ramathibodi Hospital

    International Nuclear Information System (INIS)

    Donmoon, T; Chamroonrat, W; Tuntawiroon, M

    2016-01-01

    The aim of this study is to estimate the whole body and finger radiation doses per study received by nuclear medicine staff involved in dispensing, administration of 18 F-FDG and interacting with radioactive patients during PET/CT imaging procedures in a PET/CT facility. The whole-body doses received by radiopharmacists, technologists and nurses were measured by electronic dosimeter and the finger doses by ring dosimeter during a period of 4 months. In 70 PET/CT studies, the mean whole-body dose per study to radiopharmacist, technologist, and nurse were 1.07±0.09, 1.77±0.46, μSv, and not detectable respectively. The mean finger doses per study received by radiopharmacist, technologist, and nurse were 265.65±107.55, 4.84±1.08 and 19.22±2.59 μSv, respectively. The average time in contact with 18 F-FDG was 5.88±0.03, 39.06±1.89 and 1.21±0.02 minutes per study for radiopharmacist, technologist and nurse respectively. Technologists received highest mean effective whole- body dose per study and radiopharmacist received the highest finger dose per study. When compared with the ICRP dose limit, each individual worker can work with many more 18 F- FDG PET/CT studies for a whole year without exceeding the occupational dose limits. This study confirmed that low levels of radiation does are received by our medical personnel involved in 18 F-FDG PET/CT procedures. (paper)

  17. Transport simulations of a density limit in radiation-dominated tokamak discharges: profile effects

    International Nuclear Information System (INIS)

    Stotler, D.P.

    1988-01-01

    The density limit observed in tokamak experiments is thought to be due to a radiative collapse of the current channel. A transport code coupled with a magnetohydrodynamic (MHD) equilibrium routine is used to determine the detailed, self-consistent evolution of the plasma profiles in tokamak discharges with radiated power close to or equaling the input power. The present work is confined to Ohmic discharges in steady state. It is found that the shape of the density profile can have a significant impact on the variation of the maximum electron density with plasma current. Analytic calculations confirm this result

  18. Transport simulations of a density limit in radiation-dominated tokamak discharges: Profile effects

    International Nuclear Information System (INIS)

    Stotler, D.P.

    1988-06-01

    The density limit observed in tokamak experiments is thought to be due to a radiative collapse of the current channel. A transport code coupled with an MHD equilibrium routine is used to determine the detailed, self-consistent evolution of the plasma profiles in tokamak discharges with radiated power close to or equalling the input power. The present work is confined to ohmic discharges in steady state. It is found that the shape of the density profile can have a significant impact on the variation of the maximum electron density with plasma current. Analytic calculations confirm this result. 41 refs., 9 figs

  19. Expression profile of cell cycle genes in the fish CATLA CATLA (Ham.) exposed to gamma radiation

    International Nuclear Information System (INIS)

    Anbumani, S.; Mohankumar Mary, N.

    2012-01-01

    The International Commission on Radiological Protection (ICRP) emphasized the need to protect non-human biota from the potential effects of ionizing radiation and proposed to include molecular effects such as DNA damage as endpoints. Molecular effects of ionizing radiation exposure in representative non-humans are largely unexplored and sufficient data is not available in fishes. Gene expression is a fast and sensitive end point in detecting the molecular cues as a result of ionizing radiation exposure in a wide variety of aquatic organisms under suspected environmental contamination. Exposure to ionizing radiation transiently alters gene expression profiles as cells regulate certain genes to protect cellular structures and repair damage. The present study focused on genes like Gadd45á, Cdk1 and Bcl-2 in DNA damage repair and cell cycle machinery and its implication as molecular markers of radiation exposure. This study is first of its kind showing the in vivo expression profile of cell cycle genes in fish exposed to gamma radiation. Although this preliminary investigation points to certain molecular markers of ionizing radiation, elaborate studies with various doses and dose-rates are required before these markers find application as prospective molecular markers in aquatic radiation biodosimetry

  20. Awareness of radiation exposure of thoracic CT scans and conventional radiographs: what do non-radiologists know?

    International Nuclear Information System (INIS)

    Heyer, C.M.; Peters, S.; Lemburg, S.; Nicolas, V.

    2007-01-01

    Purpose: Assessment of the knowledge of non-radiological physicians concerning radiation exposure during radiological procedures on the thorax. Material and Methods: 124 non-radiological physicians from the departments of surgery, internal medicine, anesthesiology, and neurology at a university hospital were questioned during a four-week period using a standardized questionnaire as to the effective dose (ED) of different radiological procedures on the thorax. The interviewees were asked to estimate the ED of chest X-rays and CT examinations and to compare these with the ED of other radiological methods. Length of professional experience, field of clinical training, and hierarchical position were also documented. The T-test and chi-square test were used for statistical analysis. Results: 119/124 (96.0 %) physicians with an average work experience of 8.2 years (0.3 - 32 years) were willing to participate. 47/119 (39.5 %) correctly estimated the ED of conventional chest X-ray (0.01 - 0.1 mSv), and 40/119 (33.6 %) correctly gauged the ED of adult chest CT (1 - 10 mSv). The ED of cardiac CT and pediatric chest CT without dose reduction (10 - 100 mSv) were correctly judged by 31/119 (26.1 %) and 32/119 (26.9 %), respectively. The correct ratio of the ED of chest X-ray to that of chest CT (factor 100 - 1000) was given by 28/119 (23.5 %), while 86/119 (72.3 %) underestimated the ratio. 50/119 (42.0 %) and 35/119 (29.4 %) correctly stated that the ED of pediatric chest CT without dose reduction and that of cardiac CT are greater than that of adult chest CT. 24/119 (20.2 %) and 10/119 (8.4 %) thought that the ED of low-dose chest CT is smaller than that of chest X-ray or chest MRI, respectively. The length of professional experience, field of clinical training, and hierarchical position of the participants did not have a significant influence on the test results. (orig.)

  1. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    International Nuclear Information System (INIS)

    Dauer, Lawrence T; Casciotta, Kevin A; Erdi, Yusuf E; Rothenberg, Lawrence N

    2007-01-01

    It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm 3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans

  2. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans.

    Science.gov (United States)

    Dauer, Lawrence T; Casciotta, Kevin A; Erdi, Yusuf E; Rothenberg, Lawrence N

    2007-03-16

    It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0-15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.

  3. Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans

    Directory of Open Access Journals (Sweden)

    Erdi Yusuf E

    2007-03-01

    Full Text Available Abstract Background It is estimated that 60 million computed tomography (CT scans were performed during 2006, with approximately 11% of those performed on children age 0–15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. Methods The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. Results The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. Conclusion Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.

  4. Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Vorona, Gregory A. [The Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Allegheny General Hospital, Department of Radiology, Pittsburgh, PA (United States); Ceschin, Rafael C.; Clayton, Barbara L.; Sutcavage, Tom; Tadros, Sameh S.; Panigrahy, Ashok [The Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States)

    2011-09-15

    The use of the adaptive statistical iterative reconstruction (ASIR) algorithm has been shown to reduce radiation doses in adults undergoing abdominal CT studies while preserving image quality. To our knowledge, no studies have been done to validate the use of ASIR in children. To retrospectively evaluate differences in radiation dose and image quality in pediatric CT abdominal studies utilizing 40% ASIR compared with filtered-back projection (FBP). Eleven patients (mean age 8.5 years, range 2-17 years) had separate 40% ASIR and FBP enhanced abdominal CT studies on different days between July 2009 and October 2010. The ASIR studies utilized a 38% mA reduction in addition to our pediatric protocol mAs. Study volume CT dose indexes (CTDI{sub vol}) and dose-length products (DLP) were recorded. A consistent representative image was obtained from each study. The images were independently evaluated by two radiologists in a blinded manner for diagnostic utility, image sharpness and image noise. The average CTDI{sub vol} and DLP for the 40% ASIR studies were 4.25 mGy and 185.04 mGy-cm, compared with 6.75 mGy and 275.79 mGy-cm for the FBP studies, representing 37% and 33% reductions in both, respectively. The radiologists' assessments of subjective image quality did not demonstrate any significant differences between the ASIR and FBP images. In our experience, the use of 40% ASIR with a 38% decrease in mA lowers the radiation dose for children undergoing enhanced abdominal examinations by an average of 33%, while maintaining diagnostically acceptable images. (orig.)

  5. Reducing abdominal CT radiation dose with the adaptive statistical iterative reconstruction technique in children: a feasibility study

    International Nuclear Information System (INIS)

    Vorona, Gregory A.; Ceschin, Rafael C.; Clayton, Barbara L.; Sutcavage, Tom; Tadros, Sameh S.; Panigrahy, Ashok

    2011-01-01

    The use of the adaptive statistical iterative reconstruction (ASIR) algorithm has been shown to reduce radiation doses in adults undergoing abdominal CT studies while preserving image quality. To our knowledge, no studies have been done to validate the use of ASIR in children. To retrospectively evaluate differences in radiation dose and image quality in pediatric CT abdominal studies utilizing 40% ASIR compared with filtered-back projection (FBP). Eleven patients (mean age 8.5 years, range 2-17 years) had separate 40% ASIR and FBP enhanced abdominal CT studies on different days between July 2009 and October 2010. The ASIR studies utilized a 38% mA reduction in addition to our pediatric protocol mAs. Study volume CT dose indexes (CTDI vol ) and dose-length products (DLP) were recorded. A consistent representative image was obtained from each study. The images were independently evaluated by two radiologists in a blinded manner for diagnostic utility, image sharpness and image noise. The average CTDI vol and DLP for the 40% ASIR studies were 4.25 mGy and 185.04 mGy-cm, compared with 6.75 mGy and 275.79 mGy-cm for the FBP studies, representing 37% and 33% reductions in both, respectively. The radiologists' assessments of subjective image quality did not demonstrate any significant differences between the ASIR and FBP images. In our experience, the use of 40% ASIR with a 38% decrease in mA lowers the radiation dose for children undergoing enhanced abdominal examinations by an average of 33%, while maintaining diagnostically acceptable images. (orig.)

  6. Evaluation of a method for correction of scatter radiation in thorax cone beam CT

    International Nuclear Information System (INIS)

    Rinkel, J.; Dinten, J.M.; Esteve, F.

    2004-01-01

    Purpose: Cone beam CT (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging of thorax: scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artefacts, streaks, and quantification inaccuracies. The beam stops conventional scatter estimation approach can be used for CBCT but leads to a significant increase in terms of dose and acquisition time. At CEA-LETI has been developed an original scatter management process without supplementary acquisition. Methods and Materials: This Analytical Plus Indexing-based method (API) of scatter correction in CBCT is based on scatter calibration through offline acquisitions with beam stops on lucite plates, combined to an analytical transformation issued from physical equations. This approach has been applied with success in bone densitometry and mammography. To evaluate this method in CBCT, acquisitions from a thorax phantom with and without beam stops have been performed. To compare different scatter correction approaches, Feldkamp algorithm has been applied on rough data corrected from scatter by API and by beam stops approaches. Results: The API method provides results in good agreement with the beam stops array approach, suppressing cupping artefact. Otherwise influence of the scatter correction method on the noise in the reconstructed images has been evaluated. Conclusion: The results indicate that the API method is effective for quantitative CBCT imaging of thorax. Compared to a beam stops array method it needs a lower x-ray dose and shortens acquisition time. (authors)

  7. Overranging at multisection CT: an underestimated source of excess radiation exposure.

    NARCIS (Netherlands)

    Schilham, A.; Molen, A.J. van der; Prokop, M.; Jong, H.W. de

    2010-01-01

    To reconstruct the first and last sections of a helical computed tomographic (CT) scan, the scan length is automatically extended beyond the planned image boundaries, a phenomenon known as overranging. With common 16-section CT scanning protocols, the overrange length is between 3 and 6 cm. For

  8. A model-based approach of scatter dose contributions and efficiency of apron shielding for radiation protection in CT.

    Science.gov (United States)

    Weber, N; Monnin, P; Elandoy, C; Ding, S

    2015-12-01

    Given the contribution of scattered radiations to patient dose in CT, apron shielding is often used for radiation protection. In this study the efficiency of apron was assessed with a model-based approach of the contributions of the four scatter sources in CT, i.e. external scattered radiations from the tube and table, internal scatter from the patient and backscatter from the shielding. For this purpose, CTDI phantoms filled with thermoluminescent dosimeters were scanned without apron, and then with an apron at 0, 2.5 and 5 cm from the primary field. Scatter from the tube was measured separately in air. The scatter contributions were separated and mathematically modelled. The protective efficiency of the apron was low, only 1.5% in scatter dose reduction on average. The apron at 0 cm from the beam lowered the dose by 7.5% at the phantom bottom but increased the dose by 2% at the top (backscatter) and did not affect the centre. When the apron was placed at 2.5 or 5 cm, the results were intermediate to the one obtained with the shielding at 0 cm and without shielding. The apron effectiveness is finally limited to the small fraction of external scattered radiation. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Zimmermann, Elke; Rief, Matthias; Greupner, Johannes; Hamm, Bernd [Charite Medical School, Department of Radiology, Berlin (Germany); Laule, Michael; Knebel, Fabian [Charite Medical School, Department of Cardiology, Berlin (Germany); Dewey, Marc [Charite Medical School, Department of Radiology, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2012-08-15

    To prospectively compare induced DNA double-strand breaks by cardiac computed tomography (CT) and conventional coronary angiography (CCA). 56 patients with suspected coronary artery disease were randomised to undergo either CCA or cardiac CT. DNA double-strand breaks were assessed in fluorescence microscopy of blood lymphocytes as indicators of the biological effects of radiation exposure. Radiation doses were estimated using dose-length product (DLP) and dose-area product (DAP) with conversion factors for CT and CCA, respectively. On average there were 0.12 {+-} 0.06 induced double-strand breaks per lymphocyte for CT and 0.29 {+-} 0.18 for diagnostic CCA (P < 0.001). This relative biological effect of ionising radiation from CCA was 1.9 times higher (P < 0.001) than the effective dose estimated by conversion factors would have suggested. The correlation between the biological effects and the estimated radiation doses was excellent for CT (r = 0.951, P < 0.001) and moderate to good for CCA (r = 0.862, P < 0.001). One day after radiation, a complete repair of double-strand breaks to background levels was found in both groups. Conversion factors may underestimate the relative biological effects of ionising radiation from CCA. DNA double-strand break assessment may provide a strategy for individualised assessments of radiation. (orig.)

  10. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  11. CT image biomarkers to improve patient-specific prediction of radiation-induced xerostomia and sticky saliva.

    Science.gov (United States)

    van Dijk, Lisanne V; Brouwer, Charlotte L; van der Schaaf, Arjen; Burgerhof, Johannes G M; Beukinga, Roelof J; Langendijk, Johannes A; Sijtsema, Nanna M; Steenbakkers, Roel J H M

    2017-02-01

    Current models for the prediction of late patient-rated moderate-to-severe xerostomia (XER 12m ) and sticky saliva (STIC 12m ) after radiotherapy are based on dose-volume parameters and baseline xerostomia (XER base ) or sticky saliva (STIC base ) scores. The purpose is to improve prediction of XER 12m and STIC 12m with patient-specific characteristics, based on CT image biomarkers (IBMs). Planning CT-scans and patient-rated outcome measures were prospectively collected for 249 head and neck cancer patients treated with definitive radiotherapy with or without systemic treatment. The potential IBMs represent geometric, CT intensity and textural characteristics of the parotid and submandibular glands. Lasso regularisation was used to create multivariable logistic regression models, which were internally validated by bootstrapping. The prediction of XER 12m could be improved significantly by adding the IBM "Short Run Emphasis" (SRE), which quantifies heterogeneity of parotid tissue, to a model with mean contra-lateral parotid gland dose and XER base . For STIC 12m , the IBM maximum CT intensity of the submandibular gland was selected in addition to STIC base and mean dose to submandibular glands. Prediction of XER 12m and STIC 12m was improved by including IBMs representing heterogeneity and density of the salivary glands, respectively. These IBMs could guide additional research to the patient-specific response of healthy tissue to radiation dose. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Radiation protection for the eyes of the children experiencing an operation of artificial cochlear implant against CT scan

    International Nuclear Information System (INIS)

    Liu Changsheng; Zheng Xiaohua; Li Maojing; Wei Wenzhou; Pan Ewu; Tang Guangqiao; Zhang Duanlian

    2006-01-01

    Objective: To optimize the CT scanning parameters in pediatric temporal bone examination with artificial cochlear implant and reduce its radiation hazards. Methods: The temporal bones of 87 patients with suspected inner ear disease which include 31 experienced artificial cochlear implant were scanned by HRCT. Regarding adult scan parameters as a criteria, properly adjusted the scanning dose and scanning angle until the quality of CT images was beyond the diagnosis demands. Finally the exposed doses, single scanning CT dose index weighted (CTDI w ) and dose length product (DLP) were analysed. Results: Compared with adult temporal bone scanning, the exposure value and CTDI w were reduced to 66.67%-83.33%, DLP of temporal bone scanning in pediatrics was reduced to 66.67%-83.33%, moreover, the imaging quality of tridimensional reconstruction for inner ear and implant electrode was improved. Conclusion: The proper reduction of CT scan exposure on preoperative and postoperative children with cochlear implants and the proper adjustment of scan angle can significantly reduce the exposure dose to local temporal bone and effectually avoid the damage to lens of children. (authors)

  13. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases.

    Science.gov (United States)

    Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F

    2016-05-01

    To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.

    Science.gov (United States)

    Neri, Emanuele; Faggioni, Lorenzo; Cerri, Francesca; Turini, Francesca; Angeli, Simone; Cini, Lorenzo; Perrone, Franco; Paolicchi, Fabio; Bartolozzi, Carlo

    2010-10-01

    Our aim is to compare the radiation dose associated with a low-dose CT colonography (CTC) protocol for colorectal cancer screening with that delivered by double-contrast barium enema (DCBE). CTC of twenty asymptomatic individuals (M:F = 10:10) participating to a colorectal cancer screening program and DCBE of fifteen patients (M:F = 6:9) were evaluated. For CTC, absorbed dose was determined by calculating the dose-length product for each CTC examination from measurements on a CT dose phantom equipped with a CT ion chamber. For DCBE, the free-in-air Kerma at the patient's X-ray entry surface and the Kerma-area product during fluoroscopy and fluorography were measured with a Barracuda system, with fluoroscopy times being recorded blinded to the performing operator. Effective dose at CTC was 2.17 ± 0.12 mSv, with good and excellent image quality in 14/20 (70%) and 6/20 cases (30%), respectively. With DCBE, effective patient dose was 4.12 ± 0.17 mSv, 1.9 times greater than CTC (P < 0.0001). Our results show that effective dose from screening CTC is substantially lower than that from DCBE, suggesting that CTC is the radiological imaging technique of the large bowel with the lowest risk of stochastic radiation effects.

  15. Application of low dose radiation and low concentration contrast media in enhanced CT scans in children with congenital heart disease.

    Science.gov (United States)

    Liu, Zhimin; Song, Lei; Yu, Tong; Gao, Jun; Zhang, Qifeng; Jiang, Ling; Liu, Yong; Peng, Yun

    2016-09-01

    The aim of this study was to explore the feasibility of using low dose radiation and low concentration contrast media in enhanced CT examinations in children with congenital heart disease. Ninety patients with congenital heart disease were randomly divided into three groups of 30 patients each who underwent contrast-enhanced cardiac scans on a Discovery CT750 HD scanner. Group A received 270 mg I/mL iodixanol, and group B received 320 mg I/mL iodixanol contrast media and was scanned with prospective ECG triggering mode. Group C received 320 mg I/mL iodixanol and was scanned with conventional retrospective ECG gating mode. The same weight-based contrast injection protocol was used for all three groups. Images were reconstructed using a 30% adaptive statistical iterative reconstruction (ASIR) algorithm and a 50% ASIR in groups A and B and a 30% ASIR in group C. The subjective and objective image quality evaluations, diagnostic accuracies, radiation doses and amounts of contrast media in the three groups were measured and compared. All images in the three groups met the diagnostic requirements, with the same diagnostic accuracy and image quality scores greater than 3 in a 4-point scoring system. However, ventricular enhancement and the objective noise, signal-to-noise ratio, contrast-to-noise ratio and subjective image quality scores in group C were better than those in groups A and B (all Pcontrast dose (14% lower than that of groups B and C). Enhanced CT scan images with low dose radiation and low concentration contrast media can meet the diagnostic requirements for examining children with congenital heart disease while reducing the potential risk of radiation damage and contrast-induced nephropathy. © 2016 John Wiley & Sons Ltd.

  16. Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory

    International Nuclear Information System (INIS)

    Sarmento, Daniele Martins

    2016-01-01

    Micro PET/CT scanner is an essential tool generally used for small animal molecular imaging. Fluorine-18-labeled fluorodeoxyglucose is the most widely used radioisotope in this technique. The present study aimed to evaluate the radiation levels in a micro PET/CT research laboratory of the Radiopharmacy Center at IPEN-CNEN / SP, in order to accomplish both national standards and international recommendations. The radioprotection team has classified the laboratory as supervised area; even this laboratory does not require the adoption of specific measures for protection and safety, should be done regular re-evaluation of the conditions of occupational exposures. Workplace monitoring and individual control assessment were carried out to ensure the radiological protection of all workers directly involved in handling the scanner. Initially, there was conducted a radiometric survey, as well as measurements of the external radiation level in the workplace and its surroundings. To achieve this goal, there were placed nine thermoluminescent dosimeters of CaSO 4 :Dy in preselected locations. Monthly evaluations of the occupationally exposed individuals were carried out through the use of TL dosimeters, ported in the workers' chest. Moreover, whole body measurements were performed every six months. The study period was about two-years which started in April 2014. All tests to evaluate micro PET/CT performance were based on the standard protocol of the equipment in accordance with the standard developed by the Animal PET Standard Task Force. Present study's results demonstrated that the ambient radiation levels (ambient and effective estimated radiation dose), as well as the effective shielding equipment are both adequate. This study emphasizes that it is essential to strictly follow the principles of radioprotection in workplace, whenever researches involve radioactive unsealed sources. (author)

  17. Evaluation of image quality and radiation dose using gold nanoparticles and other clinical contrast agents in dual-energy Computed Tomography (CT): CT abdomen phantom

    Science.gov (United States)

    Zukhi, J.; Yusob, D.; Tajuddin, A. A.; Vuanghao, L.; Zainon, R.

    2017-05-01

    The aim of this study was to evaluate the image quality and radiation dose using commercial gold nanoparticles and clinical contrast agents in dual-energy Computed Tomography (CT). Five polymethyl methacrylate (PMMA) tubes were used in this study, where four tubes were filled with different contrast agents (barium, iodine, gadolinium, and gold nanoparticles). The fifth tube was filled with water. Two optically stimulated luminescence dosimeters (OSLD) were placed in each tube to measure the radiation dose. The tubes were placed in a fabricated adult abdominal phantom of 32 cm in diameter using PMMA. The phantom was scanned using a DECT at low energy (80 kV) and high energy (140 kV) with different pitches (0.6 mm and 1.0 mm) and different slice thickness (3.0 mm and 5.0 mm). The tube current was applied automatically using automatic exposure control (AEC) and tube current modulation recommended by the manufacturer (CARE Dose 4D, Siemens, Germany). The contrast-to-noise ratio (CNR) of each contrast agent was analyzed using Weasis software. Gold nanoparticles has highest atomic number (Z = 79) than barium (Z = 56), iodine (Z = 53) and gadolinium (Z = 64). The CNR value of each contrast agent increases when the slice thickness increases. The radiation dose obtained from this study decreases when the pitch increases. The optimal imaging parameters for gold nanoparticles and other clinical contrast agents is obtained at pitch value of 1.0 mm and slice thickness of 5.0 mm. Low noise and low radiation dose obtained at these imaging parameters. The optimal imaging parameters obtained in this study can be applied in multiple contrast agents imaging.

  18. Evaluation of image quality and radiation dose using gold nanoparticles and other clinical contrast agents in dual-energy Computed Tomography (CT): CT abdomen phantom

    International Nuclear Information System (INIS)

    Zukhi, J; Yusob, D; Vuanghao, L; Zainon, R; Tajuddin, A A

    2017-01-01

    The aim of this study was to evaluate the image quality and radiation dose using commercial gold nanoparticles and clinical contrast agents in dual-energy Computed Tomography (CT). Five polymethyl methacrylate (PMMA) tubes were used in this study, where four tubes were filled with different contrast agents (barium, iodine, gadolinium, and gold nanoparticles). The fifth tube was filled with water. Two optically stimulated luminescence dosimeters (OSLD) were placed in each tube to measure the radiation dose. The tubes were placed in a fabricated adult abdominal phantom of 32 cm in diameter using PMMA. The phantom was scanned using a DECT at low energy (80 kV) and high energy (140 kV) with different pitches (0.6 mm and 1.0 mm) and different slice thickness (3.0 mm and 5.0 mm). The tube current was applied automatically using automatic exposure control (AEC) and tube current modulation recommended by the manufacturer (CARE Dose 4D, Siemens, Germany). The contrast-to-noise ratio (CNR) of each contrast agent was analyzed using Weasis software. Gold nanoparticles has highest atomic number (Z = 79) than barium (Z = 56), iodine (Z = 53) and gadolinium (Z = 64). The CNR value of each contrast agent increases when the slice thickness increases. The radiation dose obtained from this study decreases when the pitch increases. The optimal imaging parameters for gold nanoparticles and other clinical contrast agents is obtained at pitch value of 1.0 mm and slice thickness of 5.0 mm. Low noise and low radiation dose obtained at these imaging parameters. The optimal imaging parameters obtained in this study can be applied in multiple contrast agents imaging. (paper)

  19. Diagnosis of partial body radiation exposure in mice using peripheral blood gene expression profiles.

    Directory of Open Access Journals (Sweden)

    Sarah K Meadows

    2010-07-01

    Full Text Available In the event of a terrorist-mediated attack in the United States using radiological or improvised nuclear weapons, it is expected that hundreds of thousands of people could be exposed to life-threatening levels of ionizing radiation. We have recently shown that genome-wide expression analysis of the peripheral blood (PB can generate gene expression profiles that can predict radiation exposure and distinguish the dose level of exposure following total body irradiation (TBI. However, in the event a radiation-mass casualty scenario, many victims will have heterogeneous exposure due to partial shielding and it is unknown whether PB gene expression profiles would be useful in predicting the status of partially irradiated individuals. Here, we identified gene expression profiles in the PB that were characteristic of anterior hemibody-, posterior hemibody- and single limb-irradiation at 0.5 Gy, 2 Gy and 10 Gy in C57Bl6 mice. These PB signatures predicted the radiation status of partially irradiated mice with a high level of accuracy (range 79-100% compared to non-irradiated mice. Interestingly, PB signatures of partial body irradiation were poorly predictive of radiation status by site of injury (range 16-43%, suggesting that the PB molecular response to partial body irradiation was anatomic site specific. Importantly, PB gene signatures generated from TBI-treated mice failed completely to predict the radiation status of partially irradiated animals or non-irradiated controls. These data demonstrate that partial body irradiation, even to a single limb, generates a characteristic PB signature of radiation injury and thus may necessitate the use of multiple signatures, both partial body and total body, to accurately assess the status of an individual exposed to radiation.

  20. Analysis of radiation dose rate profile in the ambient Bhabha Atomic Research Centre, Trombay environment to evaluate radiation hazard

    International Nuclear Information System (INIS)

    Vikas; Anoj Kumar; Meena, T.R.; Vikas Kumar; Patra, R.P.; Patil, S.S.; Murali, S.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    Periodic radiological survey and its analysis are useful on a two way approach. First, it will be used to generate baseline dose profile that will be prominently important during any radiological emergency. Secondly, due to some unforeseen human acts if orphan/abandoned radioactive source were present across Bhabha Atomic Research Centre site, the same can be detected and retrieved from the incident location. Periodic radiation survey of Bhabha Atomic Research Centre, Trombay site primarily validate/serve as an indicator of integrity of the various safety measures at the different nuclear fuel cycle facilities and on the prevailing radiological status at the vicinity of the facilities at Bhabha Atomic Research Centre, Trombay site. Radiation dose profile as a quality information has been accumulated in the last five years. Analysis of data has led to the conclusion that there has been no increase in hazard over the years though the quantum of radioactivity processed at the various facilities has undergone wide increase and radiation hazard at the site continues to be very negligible. Nuclear fuel cycle activities at Bhabha Atomic Research Centre do not pose any excess radiation risk at the site

  1. Dose monitoring using the DICOM structured report: assessment of the relationship between cumulative radiation exposure and BMI in abdominal CT

    International Nuclear Information System (INIS)

    Boos, J.; Lanzman, R.S.; Meineke, A.; Heusch, P.; Sawicki, L.M.; Antoch, G.; Kröpil, P.

    2015-01-01

    Aim: To perform a systematic, large-scale analysis using the Digital Imaging and Communication in Medicine structured report (DICOM-SR) to assess the relationship between body mass index (BMI) and radiation exposure in abdominal CT. Materials and methods: A retrospective analysis of DICOM-SR of 3121 abdominal CT examinations between April 2013 and March 2014 was performed. All examinations were conducted using a 128 row CT system. Patients (mean age 61 ± 15 years) were divided into five groups according to their BMI: group A <20 kg/m 2 (underweight), group B 20–25 kg/m 2 (normal weight), group C 25–30 kg/m 2 (overweight), group D 30–35 kg/m 2 (obese), and group E > 35 kg/m 2 (extremely obese). CT dose index (CTDI vol ) and dose–length product (DLP) were compared between all groups and matched to national diagnostic reference values. Results: The mean CTDI vol and DLP were 5.4 ± 2.9 mGy and 243 ± 153 mGy·cm in group A, 6 ± 3.6 mGy and 264 ± 179 mGy• cm in group B, 7 ± 3.6 mGy and 320 ± 180 mGy• cm in group C, 8.1 ± 5.2 mGy and 375 ± 306 mGy• cm in group D, and 10 ± 8 mGy and 476 ± 403 mGy• cm in group E, respectively. Except for group A versus group B, CTDI vol and DLP differed significantly between all groups (p<0.05). Significantly more CTDI vol values exceeded national diagnostic reference values in groups D and E (2.1% and 6.3%) compared to group B (0.5%, p<0.05). Conclusion: DICOM-SR is a comprehensive, fast, and reproducible way to analyse dose-related data at CT. It allows for automated evaluation of radiation dose in a large study population. Dose exposition is related to the patient's BMI and is increased by up to 96% for extremely obese patients undergoing abdominal CT. - Highlights: • DICOM-SR was used to implement automatic CT-dose monitoring. • DICOM-SR allowed for a fast and comprehensive analysis of CT dose data. • Radiation exposure for abdominal CT was increased by up to 96% for

  2. Exposure to radiation in whole body and skull CT examinations depending upon parameters determined by the technique of examination

    International Nuclear Information System (INIS)

    Fiebach, B.J.O.; Makoski, H.B.; Ewen, K.

    1983-01-01

    The article gives the organ doses for whole body CT examinations of the thoracic region, the upper abdomen, the mesogastric and pelvic regions as well as of the lumbar vertebral column and for CT scanning of the skull. The examinations were performed using in Alderson-Rando phantom with the whole body computer thomograph Somatom DR2 supplied by Siemens and with the skull computer tomograph Siretom 2000, also supplied by Siemens, It was found that the magnitude of radiation exposure of the patient depends not only on instrument-specific properties, but also to a very large measure on the examination parameters and techniques which can vary considerably from one clinic to another. (orig.) [de

  3. Use of risk-matrix methods in the radiation safety analysis of PET/CT facilities

    International Nuclear Information System (INIS)

    Calderón Marín, Carlos F.; González González, Joaquín J.; Quesada Cepero, Waldo; Sinconegui Gómez, Belkys; Solá Rodríguez, Yeline; Duménigo Ámbar, Cruz; Guerrero Cancio, Mayka

    2016-01-01

    Introduction. Radiological safety is essential during clinical applications of ionizing radiations. Cuban legislation considers it mandatory to carry out risk analysis during safety assessments of facilities where Nuclear Medicine practices are performed. The Risk Matrix (R-M) method has been used in risk assessments in Radiotherapy and some experiences in Nuclear Medicine have been reported. In the present work the results of the safety evaluation, using the M-R method, of the first PET / CT center constructed at the Institute of Oncology and Radiobiology in Havana, are shown. The facilities will work as a satellite center and the production of radioactive drugs of 68 Ga will be conceived. The images will be acquired with a Philips Gemini TF64 scanner. Several stages and sub-stages were considered, including the design of the facility, quality control programs, review of the relevance of study requests, radiopharmaceutical reception and fractionation, 68 Ga radiopharmaceuticals production, management of Patient during the administration of radiopharmaceuticals and patient positioning. Initiating events (IEs), available barriers, as well as measures for the reduction of frequency (RFMs) of IEs and consequences (RCMs) were identified. In addition, IEs sequences are considered for CT scans. The incidence of risk reduction was assessed by the ratio of the number of times they were used and the total number of IEs. The calculation of the R-M was made by modeling the practice with the SEVRRA code R iskAssessmentSystem . Results. As a result, 76 IEs were identified with a distribution of 72% affecting patients, 7.9% in the Public and 19.7% on Occupationally Exposed Workers (TOEs). 89.5% of IEs are caused by human errors. Barriers and consequences and frequency reducers produced a risk distribution of 2.6% of high risk IEs, 64.5% medium risk and 32.9% low risk. The high-risk IEs are related to errors in the calculation of the shielding requirements of the facility that

  4. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  5. PET Motion Compensation for Radiation Therapy Using a CT-Based Mid-Position Motion Model: Methodology and Clinical Evaluation

    International Nuclear Information System (INIS)

    Kruis, Matthijs F.; Kamer, Jeroen B. van de; Houweling, Antonetta C.; Sonke, Jan-Jakob; Belderbos, José S.A.; Herk, Marcel van

    2013-01-01

    Purpose: Four-dimensional positron emission tomography (4D PET) imaging of the thorax produces sharper images with reduced motion artifacts. Current radiation therapy planning systems, however, do not facilitate 4D plan optimization. When images are acquired in a 2-minute time slot, the signal-to-noise ratio of each 4D frame is low, compromising image quality. The purpose of this study was to implement and evaluate the construction of mid-position 3D PET scans, with motion compensated using a 4D computed tomography (CT)-derived motion model. Methods and Materials: All voxels of 4D PET