WorldWideScience

Sample records for ct evaluation correlated

  1. Mediastinal lymphadenopathy in congestive heart failure: a sequential CT evaluation with clinical and echocardiographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Chabbert, Valerie; Canevet, Guillaume; Otal, Philippe; Joffre, Francis [Department of Radiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Baixas, Cecile; Galinier, Michel [Department of Cardiology, University of Toulouse, Avenue Jean-Poulhes, 31403, Toulouse (France); Deken, Valerie; Duhamel, Alain [Department of Medical Statistics, University of Lille, Place de Verdun, 59037, Lille Cedex (France); Remy, Jacques; Remy-Jardin, Martine [Department of Radiology, Hospital Calmette, University Center of Lille, Boulevard Jules Leclerc, 59037, Lille Cedex (France)

    2004-05-01

    The aim of this study was to evaluate the frequency and evolution after treatment of mediastinal lymphadenopathy associated with congestive left heart failure on CT scans in correlation with clinical and echocardiographic findings. Thirty-one consecutive patients with subacute left heart failure underwent a clinical evaluation using the NYHA classification, a CT examination, and transthoracic echocardiography at the time of initial presentation (T1). After initiation of medical treatment (T2), follow-up CT scans were systematically obtained together with a clinical evaluation. At T1, all patients showed severe (type III: n=12, 39%; type IV: n=12, 39%) to moderate (type I, n=1, 3%; type II, n=6, 19%) dyspnea with a mean ejection fraction of 39% (range 22-74%). On initial CT scans, enlarged mediastinal lymph nodes were seen in 13 patients (42%) with blurred contours in 5 patients (16%) and hazy mediastinal fat in 1 patient (3%). Significant decrease in the size of lymphadenopathy was observed between T1 and T2 (T1, n=13, 42% vs T2, n=10, 32%; p<0.05) with a concurrent decrease in the severity of dyspnea (grade III-IV dyspnea at T1, n=24, 78% vs grade I-II dyspnea at T2, n=26, 83.5%). Patients with enlarged lymph nodes at T1 showed: (a) a significantly lower ejection fraction at echocardiography than those without lymphadenopathy (mean{+-}SD value: 34{+-}12.9 vs 43{+-}13.8%; p=0.04); (b) a significantly larger diameter of the right superior pulmonary vein (mean{+-}SD value: 17{+-}2.75 vs 14{+-}3.9 mm; p=0.04); and (c) a higher frequency of abnormal peribronchovascular thickening (n=5 vs n=1; p=0.06). Mediastinal lymphadenopathy associated with subacute left heart failure was observed in 13 patients (42%), showing regression after initiation of treatment in 8 of 13 patients (62%). (orig.)

  2. Computed tomographic evaluation of the orbit and sella turcica. An atlas of anatomic-CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lo, C.Y.; Iwakawa, N. (Teikyo Univ., Tokyo (Japan). Faculty of Medicine)

    1981-08-01

    The purpose of this study is the correlation of the gross anatomy of the orbit and sella turcica with their appearance on CT images. The head of an embalmed human cadaver was scanned in axial and coronal planes according to Reid's base line, using the GE CT/T 8800 scanner with 1.5 mm collimation. The technique of Review sup(TM) target reconstruction was applied. The cadaver was sectioned in axial and coronal planes 2 to 3 mm slices. We analysed the appearance of the orbit and sella turcica in various axial and coronal sections, and then correlated the anatomic and CT appearances in corresponding planes. Based on the analysis of extra-ocular muscles and optic nerve, judgements regarding their size should be based only on true cross sections, 90/sup 0/ to the course of the individual muscle or optic nerve.

  3. Evaluation of correlation between CT image features and ERCC1 protein expression in assessing lung cancer prognosis

    Science.gov (United States)

    Tan, Maxine; Emaminejad, Nastaran; Qian, Wei; Sun, Shenshen; Kang, Yan; Guan, Yubao; Lure, Fleming; Zheng, Bin

    2014-03-01

    Stage I non-small-cell lung cancers (NSCLC) usually have favorable prognosis. However, high percentage of NSCLC patients have cancer relapse after surgery. Accurately predicting cancer prognosis is important to optimally treat and manage the patients to minimize the risk of cancer relapse. Studies have shown that an excision repair crosscomplementing 1 (ERCC1) gene was a potentially useful genetic biomarker to predict prognosis of NSCLC patients. Meanwhile, studies also found that chronic obstructive pulmonary disease (COPD) was highly associated with lung cancer prognosis. In this study, we investigated and evaluated the correlations between COPD image features and ERCC1 gene expression. A database involving 106 NSCLC patients was used. Each patient had a thoracic CT examination and ERCC1 genetic test. We applied a computer-aided detection scheme to segment and quantify COPD image features. A logistic regression method and a multilayer perceptron network were applied to analyze the correlation between the computed COPD image features and ERCC1 protein expression. A multilayer perceptron network (MPN) was also developed to test performance of using COPD-related image features to predict ERCC1 protein expression. A nine feature based logistic regression analysis showed the average COPD feature values in the low and high ERCC1 protein expression groups are significantly different (p study indicates that CT phenotype features are associated with the genetic tests, which may provide supplementary information to help improve accuracy in assessing prognosis of NSCLC patients.

  4. Mediastinal lymph node enlargement in patients with valvular heart disease: CT evaluation and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye Ju; Jung, Jung Im; Ahn, Myeong Im; Han, Dae Hee; Park, Seog Hee [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2016-04-15

    To evaluate the presence, size and location of enlarged mediastinal lymph nodes (LNs) in patients with valvular heart disease (VHD) using computed tomography scans in correlation with ejection fraction (EF). We retrospectively evaluated 30 patients with VHD, without pre-existing diseases that could cause lymphadenopathy (LAP). The presence, size, and location of LNs greater than 1 cm in short axis diameter were evaluated. The location of mediastinal LNs was recorded according to the International Association for the Study of Lung Cancer. Furthermore, we evaluated the presence of pulmonary edema, pleural effusion, and other thoracic abnormalities and evaluated EF of the heart on transthoracic echocardiography. Sixteen patients (53%) had at least 1 enlarged mediastinal LN. The most frequent locations were lower paratracheal (4R, n = 8/4L, n = 6), subcarinal (7, n = 5) and right upper paratracheal (2R, n = 4) regions. The frequency of mediastinal LAP was higher in patients with aortic regurgitation (2 of 2, 100%) followed by mitral regurgitation (8 of 11, 73%); it was also high in patients with pulmonary edema (80%), pleural effusion (81%), or both (77%), as compared to patients without pulmonary edema or pleural effusion (17%) (p = 0.001). Ten of 30 patients showed an abnormal EF of < 55%; among them, 8 had mediastinal LAP. However, the relationship between EF and LAP was not statistically significant (p = 0.058). Mediastinal LN enlargement is common in patients with VHD, especially in cases of pulmonary edema and pleural effusion. Enlarged mediastinal LNs were frequently observed with abnormal EF, however, the relationship between EF and mediastinal LAP was not statistically significant.

  5. The diagnostic value of direct CT arthrography using MDCT in the evaluation of acetabular labral tear: with arthroscopic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Yong-Chan; Kim, Jae Yoon [Chung-Ang University College of Medicine, Department of Orthopaedic Surgery, Seoul (Korea, Republic of); Choi, Jung-Ah; Lee, Guen Young; Kang, Heung Sik [Seoul National University Bundang Hospital, Departments of Radiology, Seoul National University College of Medicine, 166 Gumi-ro, Bundang-gu, Seongnam (Korea, Republic of); Lee, Young-Kyun; Koo, Kyung-Hoi [Seoul National University Bundang Hospital, Orthopaedic Surgery, Seoul National University College of Medicine, Seongnam (Korea, Republic of)

    2013-05-15

    The purpose of this study was first, to determine the sensitivity, specificity, and accuracy of MDCT arthrography (CTA) for the diagnosis of acetabular labral tear and sulcus; second, to correlate tear types using the Lage classification system on CTA compared with the arthroscopic classification; and third, to correlate CTA localization with arthroscopic localization. Direct CTA was performed using 16- or 64-slice MDCT in 126 hips (124 patients) who had chronic groin pain and positive impingement test. Images were reviewed and evaluated by two experienced musculoskeletal radiologists preoperatively. CTA findings were compared with arthroscopic findings in 58 hips (56 patients) under consensus by two orthopedic surgeons. Forty-one of the 58 hips were diagnosed as labral tears on CT arthrography. Forty-three of the 58 hips were shown to have a labral tear on arthroscopy. Sensitivity, specificity, and accuracy for detecting labral tear and sulcus by CTA were 90.7%, 86.7%, and 89.7%, and 93.8%, 97.6% and 96.6% respectively for observer 1, and 90.7% and 80.0%, 87.9% and 87.5%, 95.2%, and 93.1 % respectively for observer 2. Thirty-five out of 41 hips (85%) that were diagnosed with labral tear on CTA correlated substantially with arthroscopic Lage classification (kappa coefficient = 0.65). CTA and arthroscopic findings showed similar distribution patterns of the tears with most lesions located in antero- and postero-superior areas (p = 0.013). Direct CT arthrography using MDCT may be a useful diagnostic technique in the detection of acetabular labral tear. (orig.)

  6. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R. [Istituto di Radiologia, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy); Gaetani, P.; Rodriguez y Baena, R. [Neurosurgery, Istituto Clinico ``Humanitas``, I-20089 Rozzano (Midway Islands) (Italy); Cecchini, A. [Servizio di Radiodiagnostica, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy); Infuso, L. [Neurochirurgia, Dipartimento di Chirurgia, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy)

    1998-06-02

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 {+-} 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 {+-} 0.12 cm vs 1.09 {+-} 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients

  7. Evaluation of mediastinal lymph nodes using 18 F-FDG PET-CT scan and its histopathologic correlation

    Directory of Open Access Journals (Sweden)

    Kumar Arvind

    2011-01-01

    Full Text Available Aims and Objectives: To determine the efficacy of integrated 18 F-fluorodeoxy glucose positron emission tomography-computed tomography ( 18 F-FDG PET-CT in the evaluation and characterization of mediastinal lymph nodes into benign and malignant pathology. Methods: Thirty-five patients with mediastinal lymphadenopathies without primary neoplastic or infective lung pathologies were included in the study. The lymph nodes were detected on contrast-enhanced CT scan of the chest. All patients underwent 18 F-FDG PET-CT scan for evaluation of mediastinal lymph nodes. Results of PET-CT were compared with histopathology of the lymph nodes and sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Statistical Analysis: The data were collected prospectively and analyzed using (SPSS Inc., Chicago, IL 11.5 software. Results: Histopathology results in 35 patients revealed tuberculosis in 12, sarcoidosis in 8, and lymphoma in 15. Maximum standardized uptake value (SUVmax of the benign lymph nodes ranged from 2.3 to 11.8 with a mean±standard deviation (SD of 5.02±3.26. SUVmax of the malignant lymph nodes ranged from 2.4 to 34 with a mean±SD of 10.8±8.12. There was a statistically significant difference between benign and malignant pathology (P<0.0059. 18 F-FDG PET-CT has sensitivity of 93% and specificity of 40% with SUVmax 2.5 as the cutoff. We found the optimal SUVmax cutoff to be 6.2 as determined by the receiver-operator characteristic curve. With 6.2 as cutoff, the sensitivity, specificity, and accuracy were 87%, 70%, and 77%, respectively. Conclusion : In countries where tuberculosis and other granulomatous diseases are endemic, SUVmax cutoff value of 2.5 has low specificity. Increasing the cutoff value can improve the specificity, while maintaining an acceptable sensitivity.

  8. Correlations Between the Gradient of Contrast Density, Evaluated by Cardio CT, and Functional Significance of Coronary Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Orzan Marius

    2016-06-01

    Full Text Available Background: Assessment of the hemodynamic significance of a coronary artery stenosis is a challenging task, being extremely important for the establishment of indication for revascularization in atherosclerotic coronary artery stenosis. The aim of this study was to evaluate the role of a new marker reflecting the functional significance of a coronary artery stenosis, represented by the attenuation degree of contrast density along the stenosis by Coronary CT.

  9. Severity of acute pulmonary embolism: evaluation of a new spiral CT angiographic score in correlation with echocardiographic data

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, Ioana; Remy-Jardin, Martine; Masson, Pascal; Remy, Jacques [Department of Radiology, University Center Hospital Calmette, Boulevard Jules Leclerc, 59037 Lille Cedex (France); Medical Research Group ' ' Equipe d' Accueil no. 2682' ' , Boulevard Jules Leclerc, 59037 Lille Cedex (France); Galland, Eric; Bauchart, Jean-Jacques [Department of Cardiology, University Center Cardiology Hospital; Boulevard Jules Leclerc, 59037 Lille Cedex (France); Delannoy, Valerie [Department of Medical Statistics, University of Lille, Place de Verdun, 59037 Lille Cedex (France)

    2003-01-01

    severity score evaluated in the present study enables quantitative assessment of acute PE severity on spiral CT angiograms, readily applicable in routine clinical practice. (orig.)

  10. CT findings of acute pyelonephritis and clinical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Rha, Sung Eun; Byun, Jae Young; Kim, Ki Jun; Kim, Jong Kyu; Kim, Han Bock; Chun, Ho Jong; Bang, Byung Gi; Choi, Kyu Ho; Shinn, Kyung Sub [Catholic Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-02-01

    To evaluate postcontrast CT findings of acute pyelonephritis and correlate these with clinical findings and severities. We retrospectively reviewed the medical records and CT scans of 50 patients with abnormal CT findings among 52 patients of acute pyelonephritis whose postcontrast CT scans had been examined. Fifty cases of acute pyelonephritis were classified into three subgroups on the basis of postcontrast CT findings : Group 1(n=20, 40%) wedge-shaped lesions; Group 2(n=13, 26%) mass-like lesions; Group 3 (n=17, 34%) renal abscess formation. In each group, clinical findings and severity were analyzed and correlated with CT findings. The results were statistically analyzed. Although mean values of clinical parameters of group 1 were lower than those of group 2 and 3 with regard to all clinical parameters (including maximal temperature and duration of fever, flank pain, leukocytosis, and admission period), there was no statistically significant correlation among the three groups (p > 0.05). All cases were successfully treated with antibiotics only, despite the high rate of abscess formation (34%). Acute pyelonephritis spans a continuum of CT findings of varying severity from wedge-shaped or mass-like lesions to multifocal abscesses; postenhanced CT scan shows high sensitivity (96%) in the detection of acute pyelonephritis. Although the clinical course of groups of mass-like lesions and abscess formation was longer and more severe than that of wedge-shaped lesions, there was no statistically significant clinicoradiologic correlation among the three groups.

  11. CT diagnosis of retinoblastoma with histopathologic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Olivecrona, H. [Dept. of Radiology, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia); Agerberg, P.A. [Dept. of Radiology, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia); Huaman, A. [Dept. of Pathology, King Khaled Eye Specialist Hospital, Riyadh (Saudi Arabia)

    1994-08-01

    The authors correlated the radiologic and histopathologic characteristics of 108 retinoblastomas in 98 patients. Calcifications were demonstrable by CT scans in 92.6% of the cases, whereas only 82% were evident upon routine histologic study. Cases of severe invasion of the optic nerve beyond the lamina cribrosa and up to the surgical margin of the nerve were detected by CT scans. Lesser degrees of invasion could not be determined by the same method. Orbital extension was also demonstrable, whereas invasion limited to the sclera was rarely accessible to CT diagnosis. Choroidal invasion was not detectable. Computerized tomography detected enlargement of the ipsilateral lacrimal gland in 17.5% of patients. This phenomenon correlates with invasion of the choroid and the optic nerve. (orig.)

  12. Evaluation of Response to Therapy in a Patient with Lung Cancer: Correlation of Sclerotic Bone Lesions with F 18 FDG PET/CT and Bone Scintigraphy

    Directory of Open Access Journals (Sweden)

    Filiz Özülker

    2011-04-01

    Full Text Available A 64-year-old male patient with small cell lung cancer underwent Fluorine-18 fluorodeoxyglucose (F 18 FDG positron emission tomography (PET/CT scan which revealed multiple F 18 FDG uptake in the spine, both humeri, ribs, pelvis and proximal long bones. There was no obvious lytic or sclerotic bone destruction accompanying these lesions on CT component of the study. After the patient received six courses of chemotherapy a repeat F 18 FDG-PET/CT was performed for evaluation of therapy response. The PET/CT showed the presence of multiple sclerotic lesions on CT without FDG uptake, corresponding to the bone lesions on the previous PET/CT scan. A concomitant Tc 99m Methylene diphosphonate (Tc 99m MDP bone scintigraphy (BS revealed no pathologically increased Tc 99m MDP uptake in the skeletal system. The FDG avid lesions in the skeletal system, which were not sclerotic initially, were transformed into FDG non-avid sclerotic lesions after chemotherapy. This was attributed to the direct effect of previous successful therapy for bone metastases, leading to the transformation of metabolically active disease, into blastic metabolically inactive metastases. In conclusion, a F 18 FDG negative bone lesion, which is sclerotic on CT, may represent post-treatment osteoblastic change rather than active tumor and BS might play a role in the discrimination of these two situations. (MIRT 2011; 20: 29-33

  13. Clinical application of dual-source CT in the evaluation of patients with lung cancer: correlation with perfusion scintigraphy and pulmonary function tests.

    Science.gov (United States)

    Fraioli, F; Serra, G; Liberali, S; Fiorelli, A; Liparulo, V; Zaccagna, F; Ciccariello, G; Catalano, C; Passariello, R

    2011-09-01

    This study was done to assess the diagnostic potential of dual-source computed tomography (DSCT) in the functional evaluation of lung cancer patients undergoing surgical resection. The CT data were compared with pulmonary perfusion scintigraphy and pulmonary function tests (PFTs). All patients were evaluated with DSCT, scintigraphy and PFTs. The DSCT scan protocol was as follows: two tubes (80 and 140 kV; Care Dose protocol); 70 cc of contrast material (5 cc/s); 5- to 6-s scan time; 0.6 mm collimation. After the automatic calculation of lung perfusion with DSCT and quantification of air volumes and emphysema with dedicated software applications, the perfusional CT studies were compared with scintigraphy using a visual score for perfusion defects; CT air volumes and emphysema were compared with PFTs. The values of accuracy, sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of DSCT compared with perfusion scintigraphy as the reference standard were: 0.88, 0.84, 0.90, 0.93 and 0.88, respectively. The McNemar test did not identify significant differences either between the two imaging techniques (p=0.07) or between CT and PFTs (p=0.09). DSCT is a robust and promising technique that provides important and accurate information on lung function.

  14. Evaluation of cerebral hemodynamics with perfusion CT

    Energy Technology Data Exchange (ETDEWEB)

    Araki, Yuzo; Furuichi, Masahiro; Nokura, Hiroaki [Inuyama Central Hospital, Aichi (Japan); Sakai, Noboru [Gifu Univ. (Japan). School of Medicine

    2002-07-01

    We report on the evaluation of cerebral ischemic lesions with perfusion CT. Cerebral blood flow (CBF), cerebral blood volume (CBV) and mean transit time (MTT) of 52 patients mostly with ischemic cerebrovascular disease were analysed using the box-modulation transfer function method with 30 ml of contrast medium intravenously injected at 5 ml/sec. CBF, CBV and MTT of the middle cerebral artery (MCA) territory were 43.5{+-}4.6 ml/100 g/min, 1.9{+-}0.2 ml/100 g and 2.9{+-}0.6 seconds at the unaffected side, and 37.7{+-}7.3 ml/100 g /min, 2.1{+-}0.3 ml/100 g, 3.7{+-}0.9 seconds at the lesion side with stenosis or occlusion in the main MCA trunks or internal carotid artery, respectively. A statistically significant difference was shown in CBF and MTT values. Furthermore, there was a close correlation in CBF values of MCA territories between Xe-CT and perfusion CT (r=0.645, n=76, p<0.0001). MTT showed a positive correlation with CBV in those subjects when MTT was below 4.1 seconds (r=0.526, p<0.0001, n=83). MTT also showed a negative correlation with CBF in those patients when MTT indicated more than 4.1 seconds (r=0.818, p<0.001, n=21). These results suggest that the progression of cerebral ischemia may be classified in 4 stages using perfusion CT. The stages are as follows: stage 0; normal CBF without prolonged MTT and increased CBV, stage 1; relatively increased CBV, stage 2; significantly prolonged MTT, and stage 3; significantly deceased CBF with prolonged MTT. (author)

  15. Evaluation of dual-input perfusion in lung cancer using a 320-detector CT: Its correlation with tumor size, location, and presence of metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Roh, Mee Sook; Son, Choon Hee [Dong-A University College of Medicine, Busan (Korea, Republic of); Roh, Mee Sook [Dept. of Radiology, Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of)

    2016-11-15

    The purposes of our study were to assess the dual blood supply of lung cancer using a computed tomography (CT) perfusion technique, and to analyze the correlations between dual perfusion and various characteristics of lung cancer. Thirty-five consecutive patients with lung tumors highly suggestive of malignancy were included in this study. All subjects underwent a dual-input dynamic perfusion volume scan using a 320-detector-row CT before CT-guided biopsy. The pulmonary trunk and the descending thoracic aorta were selected for the arterial input functions. From the CT data, pulmonary arterial perfusion (PP), aortic perfusion (AP), and the perfusion index [PI = PP / (PP + AP)] were calculated using the dual-input maximum-slope method. We statistically analyzed the relationship of the perfusion data with tumor locations (central, peripheral, and abutting the pleural lesions), tumor volumes, and the presence of lymph node metastasis or distant metastasis. All subjects were pathologically diagnosed with primary lung cancers via CT-guided aspiration biopsy. The overall mean PI was 53.7 ± 7.2%. The PI showed a significant difference according to the tumor location (central, 49.2 ± 3.3%; peripheral, 56.2 ± 6.7%; abutting the pleural lesions, 48.9 ± 7.6%, p = 0.047). In contrast, no significant difference was detected in tumor size or the presence of metastasis (p > 0.05). We found that the proportion of dual perfusion in lung cancer was significantly dependent on the location of the tumor, while tumor size or the presence of metastasis was not distinctly associated with dual perfusion.

  16. Venous thromboembolic disease. CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, L. R. [Medical College of Wisconsin, Pulmonary Medicine and Intensive Care, Dept. of Diagnostic Radiology, Milwaukee, WI (United States)

    2001-12-01

    Helical and multidetector CT has proven to be a valuable imaging modality for both pulmonary embolism and deep venous thrombosis. This paper will review the sensitivity and specificity of CT and discuss diagnostic algorithms utilizing CT and more established imaging technologies.

  17. CT findings of kikuchi disease : correlation with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Nam; Kim, Dong Wook; Kim, Hyun Jin; Park, Jung Hoon; Kim, Chang Soo; Kim, Hye Sook [Maryknoll General Hospital, Pusan (Korea, Republic of)

    1999-11-01

    To evaluate by means of retrospective analysis of neck CT scans the CT findings which suggest kikuchi disease. The authors evaluated the CT findings of seven cases of Kikuchi disease histologically confirmed by excisional biopsy. Four males and three females aged between 12 and 43 (mean;28) years were included. The authors retrospectively analyzed distribution, bilaterality, the presence of aggregation, the presence of intranodal low density after contrast enhancement, the number,size, shape and location of areas of intranodal low density, and the presence of extracapsular extension in involved nodes, as seen on pre-and post-contrast CT scans. Attempts were then made to correlate the CT with the pathologic findings. The range of conditions affecting patients included palpable(7/7) and tender(6/7) nodes, fever(5/7), night sweat(2/7), leukopenia(2/7), and weight loss(1/7). The internal jugular and spinal accessory chains were involved in all seven cases, followed by the submandibular(6/7), submental(5/7), supraclavicular(1/7) and axillary(1/7) nodes. The findings observed also included bilateral involvement of the internal jugular chain(6/7), the spinal accessory chain(5/7), and the submandibular(4/6) and supraclavicular nodes(1/1). CT revealed that in all cases, pathologic lymph nodes showed aggregation in one or several nodal groups, namely a mixed homogeneous(mean, 60%)or inhomogeneous(mean, 40%) enhancement pattern;intranodal low densities with the number(1-7), size(1-7mm) and shape(oval, round, or elongated) of varying degree and predominantly (92%) peripheral location, and extracapsular extension. The CT findings which suggest Kikuchi disease in cervical lymphadenopathy were (1) involvement varying from no intranodal low density to prominent intranodal low densities; (2) intranodal low densities, with the number, size and shape of varying degree and predominantly peripheral location, which were correlated with pathologic findings, including variable intranodal

  18. Evaluation of acute pulmonary embolism by sixty-four slice multidetector CT angiography: Correlation between obstruction index, right ventricular dysfunction and clinical presentation

    Directory of Open Access Journals (Sweden)

    Noha M. Attia

    2015-03-01

    Results: Dyspnea and RVD (RVD-ratio >1 were significantly more common in patients with central pulmonary emboli. The mean OI (35% ± 19% was significantly higher in patients with dyspnea, tachycardia and obesity. A positive correlation was found between the OI and both the CT pulmonary artery diameter (r = 0.66, p  43% identified more than 90% of patients with RVD (area under the curve on ROC analysis: 0.825; p  43% proved to be an independent predictor of RVD.

  19. Intestinal disease in acquired immunodeficiency: evaluation by CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, F.D.; Maeurer, J.; Felix, R. [Strahlenklinik und Poliklinik, Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Augustenburger Platz 1, D-13 353 Berlin (Germany); Gruenewald, T.; Pohle, H.D. [Medizinische Klinik II mit Schwerpunkt Infektionskrankheiten, Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Augustenburger Platz 1, D-13 353 Berlin (Germany); Adler, A.; Hintze, R.E. [Klinik fuer Innere Medizin mit dem Schwerpunkt Gastroenterologie, Zentrale Interdisziplinaere Endoskopie, Virchow-Klinikum, Medizinische Fakultaet der Humboldt-Universitaet, Augustenburger Platz 1, D-13 353 Berlin (Germany)

    1997-12-01

    Intestinal symptoms affect most AIDS patients at some point in their disease. The purpose of this study was to evaluate the use of CT in this setting. A total of 339 abdominal CT exams were reviewed for signs of intestinal disease. Abdominal CT scans of 45 patients with intestinal symptoms were compared with colonoscopy and histologic data. The CT results were correlated with CD4{sup +} T-lymphocyte counts and patient survival. More than 14 % of all abdominal CT exams displayed signs of enteric disease. Of the 45 patients studied with both CT and colonoscopy, 35 (78 %) had signs of intestinal disease by CT. Of these 35 patients, colonoscopic signs of an intestinal lesion were found in 29 and histologic proof of disease was established in 30 cases. Colonoscopy and histology detected 8 lesions missed by CT. There were 14 cases of unspecific colitis, 15 cases of cytomegalovirus (CMV) colitis, and 4 cases of enteric tuberculosis as per biopsy. Five patients presented with Kaposi`s sarcoma and 1 with a non-Hodgkin`s lymphoma. Neither colonoscopic nor CT signs of intestinal disease did reliably distinguish between histologic subgroups. Specifically, CMV colitis could not be distinguished from unspecific colitis. CD4{sup +} T-lymphocyte counts for histologic subgroups were not significantly different, either. No colonoscopic or histologic feature predicted survival, whereas low CD4 counts and ascites on CT indicated a poor prognosis. Whereas CT detects signs of intestinal disease in most AIDS patients, these signs remain largely unspecific. Colonoscopy and biopsies provide no consistently valid standard with which to compare CT because of controversial sensitivity and specificity of these methods. The CT technique detects small bowel as well as extraintestinal disease. Therefore, CT is an important diagnostic modality in abdominal disease of immunocompromised patients. (orig.) With 7 figs., 6 tabs., 30 refs.

  20. Evaluation of CT findings for diagnosis of pleural effusions

    Energy Technology Data Exchange (ETDEWEB)

    Arenas-Jimenez, J.; Alonso-Charterina, S.; Fernandez-Latorre, F.; Gil-Sanchez, S. [Hospital General Universitario de Alicante (Spain). Dept. of Radiology; Sanchez-Paya, J. [Hospital General Universitario de Alicante (Spain). Dept. of Preventive Medicine; Lloret-Llorens, M. [Hospital Universitario La Fe, Valencia (Spain). Dept. of Radiology

    2000-04-01

    Computed tomography studies are usually used to assess patients with pleural effusions, and radiologists should be aware of the significance of different CT findings for the diagnosis of the effusion. The purpose of this study was to evaluate CT findings for etiological diagnosis of pleural effusions. Contrast-enhanced CT of the chest of 211 patients with pleural effusion of definite diagnosis were evaluated. The CT images were evaluated for the presence and extent of pleural effusion, thickening or nodules, extrapleural fat and other changes in the mediastinum or lung. The CT scans were read by two independent observers and correlation between them was evaluated. Comparison of CT findings between benign and malignant effusions, between exudates and transudates, and between empyemas and the other parapneumonic effusions were carried out. Kappa values for most CT findings were >0.85. Loculation, pleural thickening, pleural nodules, and extrapleural fat of increased density were only present in exudative effusions. Multiple pleural nodules and nodular pleural thickening were the only pleural findings limited to malignant pleural effusions. The signs were also more frequently seen in empyemas than in other parapneumonic effusions. Computed tomography findings can help to distinguish between transudates and exudates. Although there is some overlap between benign and malignant pleural effusions, pleural nodules and nodular pleural thickening were present almost exclusively in the latter. Although differences between CT findings of empyemas and the other parapneumonic effusions exist, there is no finding which can definitely differentiate between them. (orig.)

  1. Correlation between Dual-Energy and Perfusion CT in Patients with Hepatocellular Carcinoma.

    Science.gov (United States)

    Gordic, Sonja; Puippe, Gilbert D; Krauss, Bernhard; Klotz, Ernst; Desbiolles, Lotus; Lesurtel, Mickaël; Müllhaupt, Beat; Pfammatter, Thomas; Alkadhi, Hatem

    2016-07-01

    Purpose To develop a dual-energy contrast media-enhanced computed tomographic (CT) protocol by using time-attenuation curves from previously acquired perfusion CT data and to evaluate prospectively the relationship between iodine enhancement metrics at dual-energy CT and perfusion CT parameters in patients with hepatocellular carcinoma (HCC). Materials and Methods Institutional review board and local ethics committee approval and written informed consent were obtained. The retrospective part of this study included the development of a dual-energy CT contrast-enhanced protocol to evaluate peak arterial enhancement of HCC in the liver on the basis of time-attenuation curves from previously acquired perfusion CT data in 20 patients. The prospective part of the study consisted of an intraindividual comparison of dual-energy CT and perfusion CT data in another 20 consecutive patients with HCC. Iodine density and iodine ratio (iodine attenuation of the lesion divided by iodine attenuation in the aorta) from dual-energy CT and arterial perfusion (AP), portal venous perfusion, and total perfusion (TP) from perfusion CT were compared. Pearson R and linear correlation coefficients were calculated for AP and iodine density, AP and iodine ratio, TP and iodine density, and TP and iodine ratio. Results The dual-energy CT protocol consisted of bolus tracking in the abdominal aorta (threshold, 150 HU; scan delay, 9 seconds). The strongest intraindividual correlations in HCCs were found between iodine density and AP (r = 0.75, P = .0001). Moderate correlations were found between iodine ratio and AP (r = 0.50, P = .023) and between iodine density and TP (r = 0.56, P = .011). No further significant correlations were found. The volume CT dose index (11.4 mGy) and dose-length product (228.0 mGy · cm) of dual-energy CT was lower than those of the arterial phase of perfusion CT (36.1 mGy and 682.3 mGy · cm, respectively). Conclusion A contrast-enhanced dual-energy CT protocol developed

  2. CT evaluation of acetabular dysplasta in adults.

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Objective: To evaluate methods of measurement by CT and their clinical significance for acetabular dysplasia(AD) in adults. Methods: CT imaging was examined and measured in 33 adult patients with AD, compared with the normal control group of 210 adults. Results: This study showed the results of AD patients

  3. CT evaluation of thymus in myasthenia gravis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Guk Hee [Insung Hospital, Chuncheon (Korea, Republic of); Kang, Eun Young; Lee, Nam Joon; Suh, Won Hyuck [Korea University College of Medicine, Seoul (Korea, Republic of)

    1989-12-15

    The relationship between myasthenia gravis and the thymus was well establish and myasthenia gravis occurs in the presence of thymic hyperplasia or thymoma or occasionally in histologically normal thymus. Since not every patients with myasthenia gravis is a candidate for thymectomy, unless a thymoma is present, the differentiation of normal and hyperplastic thymus from thymoma becomes important. Authors reviewed retrospectively clinical records and chest CT scans of 18 patients with myasthenia gravis who underwent thymectomy during recent 5 years, to evaluate the role of CT scan. The results were as follows. 1 Of total 18 cases, 5 cases had normal thymus, 6 cases had thymic hyperplasia, 4 cases had benign thymoma and 3 cases had malignant thymoma. 2. Of 5 cases of normal thymus, no false positive cases were noted in CT scan. 3. Of 6 cases of thymic hyperplasia, CT findings were normal except 1 cases of thickened left thymic lobe. 4. Of 7 cases of thymoma, no false negative cases were noted in CT scan. 5. CT findings of benign thymoma were round or oval shaped, discrete, slightly enhancing soft tissue mass in anterior mediastinum. 6. CT findings of malignant thymoma were lobulated contoured, infiltrative, soft tissue mass lesion in anterior mediastinum with calcifications, pleural tumor implants, and SVC compression. CT yielded valuable information on differential diagnosis of thymoma, thymic hyperplasia and normal thymus. Also CT was a highly sensitive method in the detection of thymoma and determining the extent and invasiveness.

  4. Evaluation strategies in CT scanning

    DEFF Research Database (Denmark)

    uncertainty. This investigation includes measurements of two industrial items, an aluminum pipe connector and a plastic toggle, a hearing aid component. These are measured using a commercial CT scanner. Traceability is transferred using tactile and optical coordinate measuring machines, which are used...

  5. Enteroclysis CT and PEG-CT in patients with previous small-bowel surgical resection for Crohn's disease: CT findings and correlation with endoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Minordi, Laura Maria; Vecchioli, Amorino; Poloni, Giuliana; Bonomo, Lorenzo [Radiology Institute, UCSC, Department of Bio-Imaging and Radiological Sciences, Rome (Italy); Guidi, Luisa; De Vitis, Italo [Catholic University (UCSC), Gastrointestinal Department, Complesso Integrato Columbus, Rome (Italy)

    2009-10-15

    The aim of this study was to evaluate the accuracy of multidetector CT in patients with Crohn's disease (CD) relapse after ileocolic resection compared with endoscopy. Thirty-four patients were studied by endoscopy and multidetector CT, after oral administration of polyethylene glycol solution (n = 21) or after administration of methylcellulose via nasojejunal tube (n = 13). In CT examinations we evaluated the presence of mural thickening, target sign, perienteric stranding, comb sign, fibrofatty proliferation and complications. Endoscopic results were classified in accordance with Rutgeerts score (from 0 to 4). The statistical evaluations were carried out by using Fisher's exact text and {chi} {sup 2} testing (p < 0.05, statistically significant difference). Sensitivity, specificity and accuracy of the CT were 96.9%, 100% and 97%, respectively. We found a statistically significant correlation between an endoscopic score of 4 and the CT signs of target sign, perienteric stranding, comb sign and fibrofatty proliferation, and between scores 1 and 2 and mucosal hyperdensity without or with mural thickening, respectively (p < 0.05). Moreover, only CT identified the presence of jejunal and proximal ileum disease in two and three patients, respectively, and fistulas in three patients. CT is a reliable method in the diagnosis of CD relapse and shows agreement with the approved endoscopic Rutgeerts score. (orig.)

  6. Fenestral otosclerosis: significance of preoperative CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Swartz, J.D.; Faerber, E.N.; Wolfson, R.J.; Marlowe, F.I.

    1984-06-01

    Thirty-five consecutive patients with the clinical diagnosis of fenestral otosclerosis were evaluated with high-resolution computed tomography (CT). Twenty-six were diagnosed as having this disorder by CT evidence of abnormal bony excrescences at or adjacent to the oval window. Sections were also evaluated for evidence of plaque formation elsewhere in the lateral wall of the labyrinth and for surgical obstacles such as an abnormally wide cochlear aqueduct, a high jugular vein, and a dehiscent facial nerve. It is concluded that fenestral otosclerosis may be accurately diagnosed with proper CT techniques.

  7. Pulmonary alveolar proteinosis: Quantitative CT and pulmonary functional correlations

    Energy Technology Data Exchange (ETDEWEB)

    Guan, Yubao, E-mail: yubaoguan@163.com [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Zeng, Qingsi [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); Yang, Haihong; Zheng, Jinping; Li, Shiyue; Gao, Yi [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Deng, Yu [Department of Radiology, the First Affiliated Hospital of Guangzhou Medical College, Guangzhou 510120 (China); Mei, Jiang [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); He, Jianxing, E-mail: jianxing63@163.com [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China); Zhong, Nanshan, E-mail: nanshan@vip.163.com [State Key Laboratory of Respiratory Disease, Guangzhou 510120 (China)

    2012-09-15

    Objective: We assessed the relationship between quantitative computer tomography (qCT) and the pulmonary function test (PFT) or blood gas analysis in pulmonary alveolar proteinosis (PAP) patients, as well as the utility of these analyses to monitor responses to whole lung lavage (WLL) therapy. Methods: Thirty-eight PAP patients simultaneously received a CT scan and PFT. Fifteen of these patients, undergoing sequential WLL for a total of 20 lavages, also underwent chest CT scans and blood gas analysis before and after WLL, and 14 of 15 patients underwent simultaneous PFT analysis. Differences between the qCT and PFT results were analyzed by canonical correlation. Results: PAP patients with low predicted values for FVC, FEV1, D{sub LCO} and D{sub LCO}/VA indicated small airspace volume and mean lung inflation, low airspace volume/total lung volume ratio and high mean lung density. Correlation and regression analysis revealed a strong correlation between D{sub LCO} and PaO{sub 2} values with CT results. The qCT results indicated that WLL significantly decreased lung weights and mean lung densities, and improved the total airspace volume/total lung volume ratios and mean lung inflations. Conclusion: Quantitative CT may be a sensitive tool for measuring the response of PAP patients to medical interventions such as WLL.

  8. CT findings of acute pyelonephritis in children; correlation with clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Kyong; Lee, Sun Wha; Kim, Jung Eun; Lee, Seung Joo [Ewha Womans Univ., Seoul (Korea, Republic of)

    2001-02-01

    The purpose of this study was to evaluate the CT findings of acute pyelonephritis (APN) in children and to assess the correlation between these findings, clinical parameters and renal scar development, as seen on follow-up CT scans. Contrast-enhanced CT scans of thirty children in whom APN had been diagnosed were assigned to one of three groups according to whether an abscess had formed, and then to subgroups on the basis of the number of lesions in the renal parenchyme. Initial CT findings were retrospectively correlated with five clinical parameters (maximal body temperature, fever duration, leukocytosis, pyuria and admission period) and renal scar development, as seen on follow-up CT (n=12). CT scans demonstrated linear, wedge-shaped, low-density renal parenchymal lesions in 35 kidneys of 25 patients and abscesses in seven kidneys of seven patients, but no abnormal lesions in five patients. In the three groups there was correlation between these findings and some clinical parameters(maximal body temperature, fever duration and admission period), but no subgroup showed significant correlation with any clinical parameter. Renal cortical scars detected by follow-up CT were more prevalent in patients in whom initial CT demonstrated the presence of an abscess. Clinical parameters correlated with the presence of renal parenchymal hypoenhancing lesions and abscess formation, as seen on CT scans, rather than the number of renal parenchymal lesions. Renal cortical scars were more prevalent in patients in whom initial CT revealed the presence of an abscess. Enhanced CT is thought to be useful both for diagnosing APN and for predicting its clinical course in children.

  9. CT scan correlates of gesture recognition.

    Science.gov (United States)

    Ferro, J M; Martins, I P; Mariano, G; Caldas, A C

    1983-10-01

    The ability to recognise gestures was studied in 65 left-hemispheric stroke patients whose lesions were located by CT scan. In the acute stage (first month) frontal lobe and basal ganglia were frequently involved in patients showing inability to recognise gestures. In the later (third to fourth month) and chronic stages (greater than 6 months) parietal lobe involvement was important; lesions causing gesture recognition impairment were larger, had more extensive and frequent parietal involvement and produced less temporal lobe damage than those causing aural comprehension defects. These findings are discussed in the light of recent models of cerebral localisation of complex functions.

  10. Microcephaly; Correlation between cerebral CT index and developmental quotient

    Energy Technology Data Exchange (ETDEWEB)

    Azuma, Ototaka; Onozaki, Michihiko; Hidano, Fumio; Mizuguchi, Susumu; Kodama, Kimio (Akita Medical Center for Disabled Children, Kawajiri (Japan)); Komatsu, Eiko; Sakemi, Kikuo; Yamashita, Jun; Sawaishi, Ukio

    1991-09-01

    Thirty one children with microcephaly were referred to Akita Medical Center for Disabled Chilren. Of these children, 28 underwent cerebral computed tomography (CT). Cerebral CT indices were examined in relation to developmental quotient and underlying diseases. Mental retardation, cerebral palsy, epilepsy, and congenital malformations were associated with microcephaly. The most common abnormal CT finding was the ventricular-brain ratio (92.9%, 26/28). CT indices, including Evans' index, the caudal nuclei ratio, transverse width of the third ventricle, the ventricular/intracranial area ratio, the brain/intracranial area ratio, the basal cistern ratio, width of the cerebral longitudinal fissure, and integrated brain CT index, were all significantly correlated with developmental quotient. (N.K.).

  11. Correlative CT and anatomic study of the sciatic nerve

    Energy Technology Data Exchange (ETDEWEB)

    Pech, P.; Haughton, V.

    1985-05-01

    Sciatica can be caused by numerous processes affecting the sciatic nerve or its components within the pelvis including tumors, infectious diseases, aneurysms, fractures, and endometriosis. The CT diagnosis of these causes of sciatica has not been emphasized. This study identified the course and appearance of the normal sciatic nerve in the pelvis by correlating CT and anatomic slices in cadavers. For purposes of discussion, the sciatic nerve complex is conveniently divided into three parts: presacral, muscular, and ischial. Each part is illustrated here by two cryosections with corresponding CT images.

  12. Cochlear otosclerosis (otospongiosis): CT analysis with audiometric correlation

    Energy Technology Data Exchange (ETDEWEB)

    Swartz, J.D.; Mandell, D.W.; Berman, S.E.; Wolfson, R.J.; Marlowe, F.I.; Popky, G.L.

    1985-04-01

    Ninety patients who had suspected or confirmed fenestral or cochlear otosclerosis underwent CT examination. Foci of demineralization in the otic capsule were discovered in 20 ears (12 patients). Audiometric studies of the 12 patients revealed sensorineural hearing loss (SNHL) with distinct correlation of CT findings with progressivity and with involvement of the frequency level subtended by the specific area of the cochlea involved. Foci of abnormal increased density, presumably representing the healed phase of this disorder, were found less frequently than expected. There was a predilection for the basilar turn. All patients had static SNHL in the higher frequencies. The healed phase of this disorder is probably not consistently diagnosable with CT.

  13. The low attenuation area on dual-energy perfusion CT: Correlation with the pulmonary function tests and quantitative CT measurements

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa, E-mail: radokada@yamaguchi-u.ac.jp [Department of Radiology, Yamaguchi University Graduate School of Medicine (Japan); Kunihiro, Yoshie; Nakashima, Yoshiteru; Matsunaga, Naofumi [Department of Radiology, Yamaguchi University Graduate School of Medicine (Japan); Sano, Yuichi; Yuasa, Yuuki; Narazaki, Akiko; Kudomi, Shohei; Koike, Masahiro [Department of Radiology, Yamaguchi University Hospital (Japan); Kido, Shoji [Computer-aided Diagnosis and Biomedical Imaging Research Biomedical Engineering, Applied Medical Engineering Science Graduate School of Medicine, Yamaguchi University (Japan)

    2012-10-15

    Purpose: To retrospectively investigate the distribution of the low attenuation area (LAA) on dual energy perfusion CT (DEpCT) in comparison with the results of pulmonary function tests (PFTs) and quantitative CT measurements. Materials and methods: Twenty-eight patients (15 male and 13 female; mean age: 62.21 years) underwent DEpCT and PFTs within a 1-month interval. The ranges of the LAA on DEpCT were classified into six groups with attenuation values of 0–3, 0–5, 0–8, 0–10, 0–13 and 0–15 HU and the ratios of LAA in each group were compared with the percentage of forced expiratory volume in the 1st second (%FEV{sub 1.0}), FEV{sub 1.0}/forced vital capacity (FEV{sub 1.0}/FVC) and the relative area of the lung with attenuation coefficients lower than −950 HU (RA{sub −950}). Results: The LAAs on the DEpCT images were significantly correlated with the RA{sub −950}, %FEV{sub 1.0} and FEV{sub 1.0}/FVC, and the regression analysis showed that the best values of LAA on DEpCT were 0–10 HU with RA{sub −950} (r = 0.63), 0–8 HU with %FEV{sub 1.0} (r = −0.52) and 0–8 HU with FEV{sub 1.0}/FVC (r = −0.61) per patient. Conclusion: The iodine disturbance on DEpCT had a moderate correlation with the results of the PFTs and RA{sub −950}, but further examination would be needed for evaluation of iodine distribution.

  14. Quantitative dual-energy CT for phantomless evaluation of cancellous bone mineral density of the vertebral pedicle: correlation with pedicle screw pull-out strength

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L.; Booz, Christian; Bauer, Ralf W.; Kerl, J.M.; Fischer, Sebastian; Lehnert, Thomas; Vogl, Thomas J.; Khan, M.F. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany); Kafchitsas, Konstantinos [Spine Center, Asklepios Klinik Lindenlohe, Schwandorf (Germany)

    2015-06-01

    To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. Average pedicle screw vector BMD (R1, 0.232 g/cm{sup 3}; R2, 0.166 g/cm{sup 3}; R3, 0.173 g/cm{sup 3}; global, 0.236 g/cm{sup 3}) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. (orig.)

  15. Correlation Between Dual-energy and Perfusion CT in Patients with Focal Liver Lesions Using Third-generation Dual-source CT Scanner.

    Science.gov (United States)

    Xu, Jia; Zheng, Yongchang; Wang, Xuan; Xue, Huadan; Wang, Shitian; Liang, Jixiang; Jin, Zhengyu

    2017-02-20

    Objective To compare measurements of dual-energy CT iodine map parameters and liver perfusion CT parameters in patients with focal liver lesions using a third-generation dual-source CT scanner. Methods Between November 2015 and August 2016,33 patients with non-cystic focal lesions of liver were enrolled in this study. CT examinations were performed with a third-generation dual-source CT. The study CT protocol included a perfusion CT and dual-energy arterial and portal venous scans,with a time interval of 15 minutes. Iodine attenuation was measured at five region of interests including areas of high,medium,and low density within the lesion,as well as right and left liver parenchyma from the iodine map,while arterial liver perfusion (ALP),portal venous liver perfusion (PVP),and hepatic perfusion index (HPI) at the same location were measured from perfusion CT. The Pearson product-moment correlation coefficient was used to evaluate the relationship between iodine attenuation and perfusion parameters. Results The iodine attenuation at arterial phase showed significant intra-individual correlation with ALP (r=0.812,95% CI=0.728-0.885,Pperfusion CT [(14.53±0.45)mSv](t=25.212,P<0.001). Conclusion Iodine attenuation from arterial phase of dual energy CT demonstrates significant correlation with ALP and PVP,and iodine attenuation from portal venous phase demonstrates significant correlation with PVP.

  16. Evaluation of Registration Methods on Thoracic CT

    DEFF Research Database (Denmark)

    Murphy, K.; van Ginneken, B.; Reinhardt, J.;

    2011-01-01

    EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra-patient thoracic CT image pairs. Evaluation of non-rigid registration techniques is a non trivial task...

  17. Sonographic twinkling artifact for renal calculus detection: correlation with CT.

    Science.gov (United States)

    Dillman, Jonathan R; Kappil, Mariam; Weadock, William J; Rubin, Jonathan M; Platt, Joel F; DiPietro, Michael A; Bude, Ronald O

    2011-06-01

    To retrospectively correlate sonographic color Doppler twinkling artifact within the kidneys with unenhanced computed tomography (CT) in the detection of nephrolithiasis. Institutional review board approval was obtained for this retrospective HIPAA-complaint investigation, and the informed consent requirement was waived. Sonographic imaging reports describing the presence of renal twinkling artifact between January 2008 and September 2009 were identified. Subjects who did not undergo unenhanced abdominal CT within 2 weeks after sonography were excluded. Ultrasound examinations were reviewed by three radiologists working together, and presence, number, location, and size of renal twinkling artifacts were documented by consensus opinion. Sonographic findings were correlated with unenhanced CT (5-mm section width, no overlap) for nephrolithiasis and other causes of twinkling artifact. The number, location, and size of renal calculi at CT were documented. The presence of sonographic renal twinkling artifact, in general, had a 78% (95% confidence interval: 0.66, 0.90) positive predictive value for nephrolithiasis anywhere in the kidneys at CT. The true-positive rate of twinkling artifact for confirmed calculi at CT was 49% (73 of 148 twinkling foci), while the false-positive rate was 51% (75 of 148 twinkling foci). The overall sensitivity of twinkling artifact for the detection of specific individual renal calculi observed at CT was 55% (95% confidence interval: 0.47, 0.64). While renal twinkling artifact is commonly associated with nephrolithiasis, this finding is relatively insensitive in routine clinical practice and has a high false-positive rate when 5-mm unenhanced CT images are used as the reference standard. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11102128/-/DC1. RSNA, 2011

  18. Cystic adenomatoid malformation in children: CT histopathological correlation.

    Science.gov (United States)

    Lanza, C; Bolli, V; Galeazzi, V; Fabrizzi, B; Fabrizzi, G

    2007-06-01

    This study was performed to assess the accuracy of computed tomography (CT) in classifying the various types of cystic adenomatoid malformation (CAM) of the lung, as described by Stocker et al., taking histopathology as the gold standard. We retrospectively reviewed six cases of histologically proven CAM. Chest radiography, chest CT and histopathology results were available for all patients. The CT images were reviewed blinded to the histological findings, and attention was paid to the number and size of cysts so as to classify the lesions into the three groups described by Stocker et al. The classification of lesions based on the CT images was then correlated to the histopathological findings. Areas with small-sized cysts (2 cm) were seen in three cases (50%) whereas in the remaining case, the diagnosis was mixed type I and type II CAM. In one patient with type I CAM, an area of low-density consolidation around the cysts was interpreted as CAM in a context of pulmonary sequestration. The CT classification based on Stocker et al.'s categories was in agreement with the histopathological findings in four cases, whereas in the remaining two cases, the lesions were classed as type I or II on CT and as mixed (type I and II) lesions at histopathology. In one case, the CT classification was correct, but the histopathology revealed the coexistence of pulmonary sequestration. In our study, there was concordance between CT and histopathology in 66.7% of cases, whereas in 33.3% histopathology revealed areas with mixed grade lesions. CT proved to be accurate in identifying and characterising CAM and provided important information on lesion site and extension.

  19. Pseudoprominent aorta: Radiographic findings and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Brown, K.T.; Shepard, J.A.O.; Stewart, W.J.

    1985-05-01

    The presence of a persistent left-sided superior vena cava (LSVC) in the absence of a right-sided superior vena cava (RSVC) may be suspected on a posteroanterior (PA) chest radiograph because of a prominent-appearing ascending aorta, which results from the absence of the RSVC. In the absence of an RSVC, the right upper lobe abuts and outlines the course of the ascending aorta, allowing better demonstration of its profile. This report describes a patient with this finding on a PA chest radiograph. Computed tomographic correlation is presented.

  20. CT and MRI findings of calcified spinal meningiomas: correlation with pathological findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Won; Kim, Hak Jin [Pusan National University Hospital, Department of Radiology, Busan (Korea); Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Lee, In Sook [Pusan National University Hospital, Department of Radiology, Busan (Korea); Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Pusan National University School of Medicine, Department of Radiology, Busan (Korea); Choi, Kyung-Un [Pusan National University School of Medicine, Medical Research Institute, Busan (Korea); Pusan National University Hospital, Department of Pathology, Busan (Korea); Lee, Young Hwan [Catholic University of Daegu School of Medicine, Department of Radiology, Daegu (Korea); Yi, Jae Hyuck [Kyungpook National University Hospital, Department of Radiology, Daegu (Korea); Song, Jong Woon [Inje University Pusan Paik Hospital, Department of Radiology, Busan (Korea); Suh, Kyung Jin [Dongguk University Gyungju Hospital, College of Medicine, Dongguk University, Department of Radiology, Gyungju (Korea)

    2010-04-15

    This study was designed to present characteristic CT and MR findings of calcified spinal meningiomas that correlate with pathological findings and to assess the efficacy of CT for the detection of calcifications within a mass in comparison to MRI. Between 1998 and 2009, 10 out of 11 patients who had pathologically confirmed psammomatous meningiomas showed gross calcifications on CT images and were included in this study. On CT scans of the 10 patients, the distribution pattern, morphology and number of calcifications within masses were evaluated. MRI was performed in seven patients and signal intensities of masses were assessed. The pathological results analyzed semi-quantitatively were compared with the density or the size of calcifications within a mass as seen on a CT scan. Seven of 10 masses were located at the thoracic spine level. Eight masses had intradural locations. The other two masses had extradural locations. Four masses were completely calcified based on standard radiographs and CT. Symptoms duration, the size of the mass and size or number of calcifications within a mass had no correlation. The location, size, and distribution pattern of calcifications within masses were variable. On MR images, signal intensity of calcified tumor varied on all imaging sequences. All the masses enhanced after injection of intravenous contrast material. A calcified meningioma should be first suggested when extradural or intradural masses located in the spine contain calcifications regardless of the size or pattern as depicted on CT, especially in the presence of enhancement as seen on MR images. (orig.)

  1. Evaluation of bone remodeling with (18)F-fluoride and correlation with the glucose metabolism measured by (18)F-FDG in lumbar spine with time in an experimental nude rat model with osteoporosis using dynamic PET-CT.

    Science.gov (United States)

    Cheng, Caixia; Heiss, Christian; Dimitrakopoulou-Strauss, Antonia; Govindarajan, P; Schlewitz, G; Pan, Leyun; Schnettler, Reinhard; Weber, Klaus; Strauss, Ludwig G

    2013-01-01

    Rats with osteoporosis were involved by combining ovariectomy (OVX) either with calcium and Vitamin D deficiency diet (Group D), or with glucocorticoid (dexamethasone) treatment (Group C). In the period of 1-12 months, dynamic PET-CT studies were performed in three groups of rats including Group D, Group C and the control Group K (sham-operated). Standardized uptake values (SUVs) were calculated, and a 2-tissue compartmental learning-machine model (calculation of K1-k4, VB and the plasma clearance of tracer to bone mineral (Ki) as well as a non-compartmental model based on the fractal dimension (FD) was used for quantitative analysis of both groups. The evaluation of PET data was performed over the lumbar spine. The correlation analysis revealed a significant linear correlation for certain dPET quantitative parameters and time up to 12 months after induction of osteoporosis. Based on the (18)F-Fluoride data, we noted a significant negative correlation for K1 (the fluoride/hydroxyl exchange) in the Group C and a significant positive correlation for k3, SUV (bone metabolism) and FD in the Group K. The evaluation of the (18)F-FDG data revealed a significant positive correlation for SUV (glucose metabolism) only in Group C. The correlation between the two tracers revealed significant results between K1 of (18)F-Fluoride and SUV of FDG in Group K as well as between FD of (18)F-Fluoride and FDG in Group D and C and between k3 of (18)F-Fluoride and SUV of FDG in Group C.

  2. Evaluation of bone remodeling with 18F-fluoride and correlation with the glucose metabolism measured by 18F-FDG in lumbar spine with time in an experimental nude rat model with osteoporosis using dynamic PET-CT

    Science.gov (United States)

    Cheng, Caixia; Heiss, Christian; Dimitrakopoulou-Strauss, Antonia; Govindarajan, P; Schlewitz, G; Pan, Leyun; Schnettler, Reinhard; Weber, Klaus; Strauss, Ludwig G

    2013-01-01

    Rats with osteoporosis were involved by combining ovariectomy (OVX) either with calcium and Vitamin D deficiency diet (Group D), or with glucocorticoid (dexamethasone) treatment (Group C). In the period of 1-12 months, dynamic PET-CT studies were performed in three groups of rats including Group D, Group C and the control Group K (sham-operated). Standardized uptake values (SUVs) were calculated, and a 2-tissue compartmental learning-machine model (calculation of K1-k4, VB and the plasma clearance of tracer to bone mineral (Ki) as well as a non-compartmental model based on the fractal dimension (FD) was used for quantitative analysis of both groups. The evaluation of PET data was performed over the lumbar spine. The correlation analysis revealed a significant linear correlation for certain dPET quantitative parameters and time up to 12 months after induction of osteoporosis. Based on the 18F-Fluoride data, we noted a significant negative correlation for K1 (the fluoride/hydroxyl exchange) in the Group C and a significant positive correlation for k3, SUV (bone metabolism) and FD in the Group K. The evaluation of the 18F-FDG data revealed a significant positive correlation for SUV (glucose metabolism) only in Group C. The correlation between the two tracers revealed significant results between K1 of 18F-Fluoride and SUV of FDG in Group K as well as between FD of 18F-Fluoride and FDG in Group D and C and between k3 of 18F-Fluoride and SUV of FDG in Group C. PMID:23526138

  3. Correlation of the CT analysis and audiometry in otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Kiyomizu, Kensuke; Tono, Tetsuya; Yang, Dewen; Haruta, Atsushi; Kodama, Takao; Kato, Eiji; Komune, Shizuo [Miyazaki Medical Coll., Kiyotake (Japan)

    1998-11-01

    Thirty-three patients (62 ears) with surgically confirmed otosclerosis underwent a preoperative CT examination in order to determine the presence of any correlation between the audiometric and CT findings. Based on the CT findings, the ears were classified into five groups as follows: group A; 25 ears (40.3%) with normal CT findings, group B1; 15 ears (24.2%) with demineralization in the region of the fissula antefenestram, group B2; 12 ears (19.4%) with demineralization around the anterior to the oval window, group B3; 4 ears (6.5%) with demineralization surrounding the cochlea, and group C; 6 ears (9.7%) with thick anterior and posterior plaques. The expansion of demineralization led to an increase in average bone conduction hearing level: group A ; 27.1 dB, group B1; 30.6 dB, group B2; 34.6 dB, group B3; 36.7 dB, and group C; 30.3 dB. This increase is most likely due to progressive labyrinthine otosclerosis. Group C in the average air-bone gap was greater (37.5 dB) than that in the patients with demineralization, group B1 (21.6 dB), group B2 (28.2 dB), group B3 (26.7 dB), the Carhart effect of group C was smaller than that of any other groups, thus suggesting the mode of otosclerosis progression in group C to be different from that in patients with demineralization. The results of the present study indicate that the preoperative CT findings of otosclerosis correlate with the audiometry findings, thus proving the usefulness of CT in diagnosing otosclerosis. (author)

  4. Correlation between contrast enhancement of portal vein and spleen size in dual-phase spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Seung Eon; Choi, Jong Cheol; Nam, Kyung Jin; Jung, Won Jung; Goo, Bong Sik; Park, Byung Ho; Lee, Young Ii; Chung, Duck Hwan [Donga Univ. College of Medicine, Pusan (Korea, Republic of)

    1996-10-01

    To evaluate using spiral CT the effect of spleen size on blood flow in the portal venous system and to know the usefulness of this evaluation. Fifty-one patients without evidence on spiral CT scan of abnormality thought to affect portal venous flow presented between December 1994 and June 1995. We measured spleen size and Hounsfield units of portal vein in dual-phase, and calculated the ratio of the unit in the portal phase to that in the arterial phase. Spleen size was measured, using the length of X-axis by that of Z-axis on spiral CT scan. We then measured the correlation between the two values. CT was performed with a Somatom Plus-S scanner(Siemens, Erlangen, Germany). A total dose of 120ml of non-ionic contrast material(Ultravist) was administered at a rate of 3 ml/sec. Arterial and portal phase were obtained after 30 seconds and 60 seconds from the begining of the contrast agent injection. The correlation between spleen size and contrast enhancement of the portal vein was relatively significant(Pearson's correlation coefficient(r)=0.41801). Spleen size significantly affects portal venous flow on spiral CT scan. The evaluation of spleen size and contrast enhancement of the portal vein could be useful in the differential diagnosis of diseases which affect portal venous flow.

  5. A STUDY OF CORRELATION BETWEEN NASAL ENDOSCOPY AND CT SCAN IN CASES OF CHRONIC RHINOSINUSITIS

    Directory of Open Access Journals (Sweden)

    Arun Kumar

    2015-07-01

    Full Text Available BACKGROUND: The accurate diagnosis of Chronic Rhinosinusitis (CRS is still a challenge therefore, the American Academy of Otorhinolaryngology - Head and Neck Surgery (AAO - HNS 1 has met in a multidisciplinary encounter and formulated a consensus based on only clinical symptoms. The computed tomography (CT scan and the nasal endoscopy (NE were introduced to make an accurate diagnosis of CRS and verify the disease severity. AIM: The aim of this study is to make a correlation between nasal endoscopy and CT scan in cases of clinically diagnosed Chronic Rhinosinusitis patients. METHOD: A study was carried out on 90 patients at Jhalawar Medical College, Jhalawar (Raj. during Sept. 20 12 to Dec. 2014. Diagnostic Nasal Endoscopy and CT Scan PNS done in patients, suffering from Chronic Rhinosinusitis. As a classification instruments, Metson / Gliklich's classification was used to evaluate the tomographic diagnosis and the Stankiewicz / Chow' s classification to evaluate the endoscopic diagnosis of Chronic Rhinosinusitis. RESULTS: Our study showed high specificity of endoscopy in comparison to CT scan though CT scan results are more sensitive. CONCLUSION: Endoscopy can confirm a Chronic Rhinosi nusitis diagnosis, but cannot rule it out, and that CT should be performed in cases of suspected CRS even if mucopurulence is not noted on endoscopy. The CT scan and the nasal endoscopy making easier the treatment planning and the disease resolution.

  6. Pathophysiology of acute small bowel disease with CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Sarwani, N., E-mail: nsarwani@hmc.psu.ed [Department of Radiology, Section of Abdominal Imaging, Penn State Milton Hershey Medical Center, Hershey, PA (United States); Tappouni, R.; Tice, J. [Department of Radiology, Section of Abdominal Imaging, Penn State Milton Hershey Medical Center, Hershey, PA (United States)

    2011-01-15

    The objective of this article is to review the pathophysiology of acute small bowel diseases, and to correlate the mechanisms of disease with computed tomography (CT) findings. Disease entities will be classified into the following: immune mediated and infectious causes, vascular causes, mechanical causes, trauma, and others. Having an understanding of acute small bowel pathophysiology is a useful teaching tool, and can lead to imaging clues to the most likely diagnosis of acute small bowel disorders.

  7. CT and MR imaging findings of xanthogranulomatous cholecystitis: correlation with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Shuto, R.; Kiyosue, H.; Komatsu, E.; Matsumoto, S.; Mori, H. [Oita Medical Univ. (Japan). Dept. of Radiology; Kawano, K. [Oita Medical Univ. (Japan). Dept. of First Surgery; Kondo, Y.; Yokoyama, S. [Oita Medical Univ. (Japan). Dept. of First Pathology

    2004-03-01

    The aim of this study was to evaluate CT and MRI findings in xanthogranulomatous cholecystitis (XGC) and to correlate the imaging findings with various pathologic parameters. The study included 13 patients with histopathologically confirmed XGC. The CT (n=13) and MRI (n=5) obtained in these patients were evaluated retrospectively. On CT, low-attenuation areas in the wall of XGC correlated with foam and inflammatory cells or necrosis and/or abscess in XGC. Areas of iso- to slightly high signal intensity on T2-weighted images, showing slight enhancement at early phase and strong enhancement at last phase on dynamic study, corresponded with areas of abundant xanthogranulomas. Areas with very high signal intensity on T2-weighted images without enhancement corresponded with necrosis and/or abscesses. Luminal surface enhancement (LSE) of gallbladder wall represented preservation of the epithelial layer. The early-enhanced areas of the liver bed on dynamic CT and MR images corresponded with accumulation of inflammatory cells and abundant fibrosis. Our results indicate that CT and MRI findings correlate well with the histopathologic findings of XGC.

  8. Thin section helical CT findings of klastskin tumor and benign stricture: cholangiographic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Guk Myeong; Han, Joon Koo; Kim, Tae Kyoung; Choi, Byung Ihn; Kim, Sun Whe; Cho, Yun Ku; Han, Man Chung; Yeon, Kyung Mo [Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    The purpose of this study was (1) to describe the thin section helical CT findings of hilar cholangiocarcinoma and of benign strcture, and to discuss the differential points between the two disease entities and (2) using cholangiographic correlation, to evaluate the diagnostic accuracy of helical CT in determining the extent of hilar cholangiocarcinoma. Twenty-seven patients with hilar cholangiocarcinoma and eight with benign biliary dilatation were studied. All except four with hilar cholangiocarcinoma, who underwentCT using a conventional scanner, were studied with two-phase helical CT. In all patients, cholangiographs were obtained by digital fluoroscopy after the injection of contrast materials into PTBD catheters. The level of obstruction was classified according to Bismuth, and 35 CT scans were studied blindly and retrospectively by two radiologists. The findings were analyzed for the presence of tumor, and then divided into two groups(cholangiocarcinomas and benign strictures), and the positive predictive value was calculated. The CT images of klatskin tumor were analyzed with special emphasis on the level and shape of the hilar obstruction. The level of biliary obstruction and extent of the tumor were carefully correlated with the results of cholangiography. Thin-section spiral CT correctly identified all tumor mass as a focal wall thickening obliterating the lumen. On arterial/portal phase CT scanning, 81% of infilterative tumors showed high attenuation. In all patients, differentiation between benign stricture and klaskin tumor was possible;correct identification of the level of obstruction and extent of tumor, according to Bismuth's classification, was possible in 63% of cases. For correct diagnosis of hilar cholangiocarcinoma and differentiation of benign stricture, helical CT was highly accurate and effective. Because of limital Z-axis resolution, however, the exact intraductal extent of the tumor was less accorately diagnosed.=20.

  9. Temporal bone trauma: correlative study between CT findings and clinical manifestations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hee; Kim, Hyung Jin; Kim, Jae Hyoung [College of Medicine, Gyeongsang National University, Jinju (Korea, Republic of)

    1994-11-15

    To assess how accurately computed tomography (CT) can demonstrate the abnormal findings which are believed to cause the clinical signs and symptoms of hearing loss (HL), vertigo and facial paralysis (FP) in patients with temporal bone trauma. The authors studied CT scans of 39 ears in 35 patients with temporal bone trauma. CT scans were performed with 1-1.5 mm slice thickness and table incrementation. Both axial and coronal scans were obtained in 32 patients and in three patients only axial scans were obtained. We analyzed CT with special reference to the structural abnormalities of the external auditory canal, middle ear cavity, bony labyrinth, and facial nerve canal, and correlated these findings with the actual clinical signs and symptoms. As to hearing loss, we evaluated 32 ears in which pure tone audiometry or brainstem evoked response audiometry had been performed. With respect to the specific types of HL, CT accurately showed the abnormalities in 84% (16/19) in conductive HL, 100% (2/2) in sensorineural HL, and 25% (2/8) for mixed HL. When we categorized HL simply as conductive and sensorineural, assuming that mixed be the result of combined conductive and sensorineural HL, CT demonstrated the abnormalities in 89% (24/27) for conductive HL and 50% (5/10) for sensorineural HL. Concerning vertigo and FP, CT demonstrated abnormalities in 67%(4/6), and 29% (4/14), respectively. Except for conductive HL, CT seems to have a variable degree of limitation for the demonstration of the structural abnormalities resulting sensorineural HL, vertigo or facial paralysis. It is imperative to correlate the CT findings with the signs and symptoms in those clinical settings.

  10. Tumor angiogenesis and dynamic CT in colorectal carcinoma: Radiologic-pathologic correlation

    Institute of Scientific and Technical Information of China (English)

    Zi-Ping Li; Quan-Fei Meng; Can-Hui Sun; Da-Sheng Xu; Miao Fan; Xu-Feng Yang; Dong-Ying Chen

    2005-01-01

    AIM: To investigate the correlation between microvessel density and spiral CT perfusion imaging in colorectal carcinoma.METHODS: Thirty-seven patients, with histologically proven colorectal carcinoma, underwent water enema spiral CT scan. The largest axial surface of the primary tumor was searched on unenhanced spiral CT images. At this level, the enhanced dynamic scan series was acquired.Time-density curves (TDC) were created from the region of interest drawn over the tumor, target artery by Toshiba Xpress/SX spiral CT with perfusion functional software.Then the perfusion was calculated. Microvessel density(MVD) was evaluated using immunohistochemical staining of surgical specimens with anti-CD34, and then MVD was correlated with perfusion.RESULTS: MVD of colorectal carcinomas was 33.11-173.44,mean 87.28, and perfusion was 15.60-64.80 mL/min/100 g, mean 39.74 mL/min/100 g. MVD and perfusionwere not associated with invasive depth, metastasis and disease stage, and they all decreased with increasing Dukes' stage, but no significant correlation was found between them (r= 0.L8, P = 0.29).CONCLUSION: There is no significant correlation between MVD and perfusion. Neovascularizaton and perfusion are highly presented in early colorectal carcinoma.CT perfusion imaging may be more suited for assessing tumorigenesis in colorectal carcinoma than histological MVD technique.

  11. Diseases affecting the peribronchovascular interstitium: CT findings and pathologic correlation.

    Science.gov (United States)

    Castañer, Eva; Gallardo, Xavier; Pallardó, Yolanda; Branera, Jordi; Cabezuelo, María Angeles; Mata, Josep María

    2005-01-01

    Central bronchi and pulmonary arteries are surrounded and enveloped by a strong connective-tissue sheath termed the peribronchovascular interstitium, extending from the level of the pulmonary hila into the peripheral lung. Thickening of the peribronchovascular interstitium can be seen in a wide variety of diseases. The CT appearance can be smooth, nodular, or irregular depending on the underlying cause. Many of the diseases affecting the peribronchovascular interstitium are entities that show a predilection for lymphatic routes, such as sarcoidosis, pulmonary lymphangitic carcinomatosis, silicosis, and lymphoproliferative disorders. There are other entities that mainly affect the peribronchovascular interstitium without a predominant perilymphatic distribution, such as hydrostatic pulmonary edema, cryptogenic organizing pneumonia, Kaposi's sarcoma, interstitial pulmonary emphysema, and interstitial hemorrhage. Although there is an overlap in radiologic features, some CT findings are useful in differentiating among these entities. When CT shows mainly peribronchovascular abnormality, the differential diagnosis is considerably reduced, and it is generally possible to reach the correct diagnosis by considering the clinical context. We illustrate the CT findings and pathologic correlation for a number of different disorders that mainly affect the peribronchovascular interstitium.

  12. Correlation between CT and tympanogram in secretory otitis media

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Toshimitsu; Sakurai, Tokio; Taniguchi, Kazuhiko; Takahashi, Kuniaki (Iwaki-Kyoritsu General Hospital, Iwaki, Fukushima (Japan)); Ikeda, Katsuhisa; Kawamoto, Kazutomo

    1984-11-01

    In an attempt to evaluate the feasibility of the tympanometry in detecting the middle ear effusion (MEE) in secretory otitis media (SOM) in childhood, the findings of the computed tomography (CT) were evaluated whether they were compatible with that of tympanometry in 27 cases (51 ears) of SOM. Tympanometry (tympanogram, static compliance measurement and stapedial reflex test), pure tone audiometry and high resolution CT were performed sequentially, and the CT findings were compared with the results of the other tests. The conclusions obtained were summarized as follows. 1. Among the tests performed, tympanogram appeared to be the most reliable measure in detection of MEE. 2. Fifteen ears out of 16 with type B tympanograms and 6 ears out of 15 with type C/sub 2/ tympanograms, were diagnosed by CT as having MEE. MEE occupied the entire middile ear space in most ears with type B tympanograms. By contrast, in the ears with type C/sub 2/ tympanograms, air containing space of varying size were always observed even in the ears with MEE.

  13. What is the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after CT?

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kyung Mi [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Lee, Kwanseop [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of)], E-mail: kwanseop@hallym.or.kr; Kim, Min-Jeong; Yoon, Hoi Soo; Jeon, Eui Yong; Koh, Sung Hye [Department of Radiology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Min, Kwangseon [Department of Pathology, Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Choi, Dongil [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine (Korea, Republic of)

    2010-04-15

    The objective of our study was to estimate the complementary role of ultrasound evaluation in the diagnosis of acute appendicitis after abdominoplevic CT. A total of 104 patients initially underwent abdominopelvic CT before appendix US due to acute abdominal pain. All CT examinations were evaluated retrospectively for the presence of acute appendicitis. The findings of appendix on CT were classified into five categories (definite appendicitis, probably appendicitis, equivocal CT findings for diagnosis of appendicitis, probably not appendicitis, and normal looking appendix). Appendix US images and their radiologic reports were also evaluated retrospectively. Then, CT and US findings were correlated with clinical or pathologic diagnosis. Three all patients with definite appendicitis initially on CT again showed US findings of appendicitis. In the 32 patients of probably appendicitis on CT, US showed normal looking appendix in seven patients (21.8%, 7 of 32) who improved with medical treatment and discharged. In the 16 patients of equivocal CT findings for diagnosis of appendicitis, US showed appendicitis in seven patients (43.8%, 7 of 16) and normal looking appendix in nine patients. In the 12 patients of probably not appendicitis on CT, US showed acute appendicitis in two patients (16.7%, 2 of 12). In the 41 patients of normal looking appendix on CT, US showed acute appendicitis in five patients (12.2%, 5 of 41). US reevaluation enables us to avoid misdiagnosis of appendicitis on CT and improve diagnostic accuracy of acute appendicitis.

  14. Correlation between Dynamic Spiral-CT Enhancement Parameters and Tumor Angiogenesis in Renal Cell Carcinomas

    Institute of Scientific and Technical Information of China (English)

    Jinhong Wang; Weixia Chen; Xiuhui Zhang; Pengqiu Min; Rongbo Liu; Hengxuan Yang

    2005-01-01

    OBJECTIVE To prospectively investigate the correlation between the enhancement parameters of a dynamic-CT (D-CT) scan for renal cell carcinomas (RCC) and the carcinoma tissue microvessel density (MVD) in renal cell carcinomas (RCC).METHODS Twenty-four cases of renal cell carcinoma verifyied by histopathology were scanned via dynamic-CT, followed by a whole kidney scan. Enhancement parameters were derived as follows .The slope of the contrast media uptake curve (S), area under the curve(AR), the density difference before and after tissue enhancement (△HU) and tissue blood ratio (TBR) were calculated for all lesions. Time-density curve types were ranked from the lowest to the highest of the slope of the contrast media uptake curve (S) as type A, B and C. Pathologic slides corresponding to the CT imagings were subjected to CD34 monoclonal antibodies, then were evaluated with an image analyzer to count hot spots of MVD. By using the Spearman rank correlation tests, statistical analysis was performed to determine the strength of the relationship between enhancement parameters and MVD determinations.RESULTS The carcinoma tissue MVD showed a direct correlation with the enhancement parameters of D-CT (r=0.54, r=0.62, r=0.55, r=0.64, r=0.44,P< 0.05). Moreover the S, △HU, TBR and type curves all demonstrated a strong correlation with the MVD. By analyzing the various enhancement parameters of the time-density curves, the relationship between the enhancement CT parameters corresponding to the tumor's MVD was identified.CONCLUSION A dynamic spiral-CT scan may be a helpful method as a measurement of tumor angiogenesis in vivo in RCC.

  15. 慢性肝病患者CT血流灌注与肝纤维化血清指标相关性探讨%Evaluation of CT perfusion to liver fibrosis and cirrhosis and the correlation with serum indicator

    Institute of Scientific and Technical Information of China (English)

    张晓莹; 姜诗路; 许晓岚; 徐凤娣; 郑海宁

    2011-01-01

    目的:探讨肝脏纤维化及早期肝硬化患者CT血流灌注参数与肝纤维化血清指标的相关性.方法:使用GE64层螺旋CT灌注技术计算40例经病理证实不同分期肝纤维化患者及10例正常对照人群肝血流量(blood flow,BF)、肝血容积(blood volume,BV)、肝动脉血流(hepatic arteral fraction,HAF)、平均通过时间(mean transit time,MTT)、表面通透性(permeability surface,PS)等血流动力学参数,同时检测肝纤维化血清学指标:血清Ⅲ型胶原(typeⅢ,procollagen peptide)、透明质酸(hyaluronic,HA)、层粘蛋白(laminin,LN)、Ⅳ型胶原(collagen,CIV),并与病理结果对照.结果:自肝炎到早期肝硬化阶段,S0,S2,S4期的HAF呈升高趋势,BV和BF都升高,MTT缩短,PS降低,在不同时期BV、BF、HAF和MTT的差异有统计学意义.血清学指标HA、LN、胶原Ⅳ、胶原Ⅲ及CT灌注指标BV、BF、MTT、PS、HAF之间,除HA与MTT、PS与LN,MTT与Ⅳ型胶原呈负相关,其余各指标间均呈正相关.结论:肝脏血流动力学微循环变化反映了肝纤维化及早期肝硬化的病理过程.%Objective: To evaluate the correlation of hepatic perfusion with multi-slice spiral CT and several serum markers in the diagnosis of liver fibrosis and cirrhosis. Methods: CT perfusion parameters of blood flow (BF). blood volume ( BV) . hepatic arteral fraction ( HAF) . mean transit time ( MTT) , permeability surface ( PS) along with the serum fibrosis markers: procollagen peptide (typeⅢ), hyaluronic( HA) , laminin (LN) , Ⅳ collagen were achieved and compared in different groups proved by pathology. Results : CT pcrfusion parameters had significant differences in control and different fibrosis groups. BV. BF and HAF were increasing while MTT shorten and PS decrease with fibrosic degree. HA was inverse correlation with MTT and PS with LN, MTT with collagen Ⅳ. other perfusion paramerers were direct correlation with serum indicators. Conclusion: CT perfusion parameters can

  16. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger;

    2012-01-01

    information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank......Introduction – Emphysema is defined by pathology, but is most precisely evaluated in vivo by computed tomography (CT). Aims – were to determine the reproducibility of visual evaluation of emphysema, i.e. the observer variability, and furthermore to compare the visual evaluations to automatic CT...

  17. CT of lumbar disc herniation: correlation with surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suk Yl; Lee, Dong Jin; Sung, Kyu Bo; Woo, Won Hyung [Korea General Hospital, Seoul (Korea, Republic of)

    1986-10-15

    CT from forty nine patients with 53 surgical disc explorations were reviewed and correlated with surgical findings. The results were as follows: 1. Frequent locations of HNP were in L4-5 (65%) and L5-S1 (31%). The most common type of HNP was paramidine type (71%). 2. Focal protrusion of the posterior margin of disc and obliteration of epidural fat pad were observed in all of cases (100%) and other common findings were indentation of epidural sac in 46 cases (96%) and compression of nerve root sleeve in 33 cases (69%). 3. Cephalad and caudad extension of protruded soft tissue density in the spinal canal was observed in 15 cases (31%) with variable degree. And more than 6mm extension were provided to be extruded disc in 9 cases. 4. Vacuum phenomenon was demonstrated in 5 cases (10%) and was accompanied with bulging annulus. 5. Forty eight herniated nucleus (HNP) were confirmed surgically in 44 patients. Misinterpretations were made in 4 instances (4 patients); 1 because of lumbar scoliosis, 1 because of spondylolisthesis, and the other 2 because of calcified posterior longitudinal ligament and bulging annulus. One case of true negative examination was central and foraminal stenosis in spinal CT. Thus, sensitivity, specificity and overall accuracy of lumbar spine CT in HNP were 92%, 100% and 92%, respectively.

  18. CT assessment of the correlation between clinical examination and bone involvement in oral malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Albuquerque, Marco Antonio Portela; Oliveira, Ilka Regina Souza; Cavalcanti, Marcelo Gusmao Paraiso [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Odontologia. Dept. de Radiologia], e-mail: mgpcaval@usp.br; Kuruoshi, Marcia Etsuko [Universidade de Sao Paulo (USP), SP (Brazil). Hospital Universitario. Dept. de Radiologia

    2009-07-01

    Oral cancers have a tendency to invade the surrounding bone structures, and this has a direct influence on the treatment management and on outcomes. The objective of this study was to correlate the clinical parameters (location, clinical presentation and TNM staging) of oral malignant tumors that can be associated with a potential of bone invasion and determine the accuracy of clinical examination to predict bone involvement, using computed tomography (CT). Twenty five patients, with oral malignant tumors were submitted to clinical and CT examinations. CT was considered the standard parameter to evaluate the presence of bone involvement. Clinical assessment of location, presentation form and TNM staging of the tumors were then compared to the CT findings in predicting bone involvement. Bone involvement was observed in 68% of the cases. It was predicted that tumors located in the retromolar trigone and hard palate, with a clinical aspect of infiltrative ulcer or nodule and classified in stage IV had a high potential to cause bone involvement. The clinical examination assessment of these tumors showed to be a valuable tool to predict bone invasion, with high sensitivity (82%) and specificity (87.5%), based on the results found in the CT images. No statistical significance was found between the CT and clinical examinations regarding bone involvement. The identification of some clinical parameters such as location, clinical presentation, and TNM stage, associated with a detailed clinical examination, was considered a valuable tool for the assessment of bone destruction by oral malignant tumors. (author)

  19. Computed tomography (CT) findings in 88 neurofibromatosis 1 (NF1) patients: Prevalence rates and correlations of thoracic findings

    Energy Technology Data Exchange (ETDEWEB)

    Ueda, Ken, E-mail: k-ueda@radiol.med.osaka-u.ac.jp [Department of Radiology, Osaka University Graduate School of Medicine (Japan); Honda, Osamu [Department of Radiology, Osaka University Graduate School of Medicine (Japan); Satoh, Yukihisa [Department of Diagnostic Radiology, Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan); Kawai, Misa; Gyobu, Tomoko; Kanazawa, Toru; Hidaka, Shojiro; Yanagawa, Masahiro [Department of Radiology, Osaka University Graduate School of Medicine (Japan); Sumikawa, Hiromitsu [Department of Diagnostic Radiology, Osaka Rosai Hospital (Japan); Tomiyama, Noriyuki [Department of Radiology, Osaka University Graduate School of Medicine (Japan)

    2015-06-15

    Highlights: • Various thoracic CT findings, including cysts, mediastinal masses, etc. were found. • Cysts show upper and peripheral dominant distribution. • The number, size, and distribution of the pulmonary cysts in NF-1 revealed significant correlation. • It is suspected that thoracic CT findings in NF-1 occur independently. - Abstract: Purpose: To evaluate the prevalence rates and the correlations of thoracic computed tomography (CT) findings of neurofibromatosis 1 (NF1) in 88 patients. Materials and methods: Chest CT images of 88 NF1 patients were independently reviewed by three observers, and the CT findings were evaluated. If abnormal findings were present, their number, size, and distribution were recorded. The prevalence rate of each CT finding was calculated, and the correlations between CT findings were analyzed. Results: Of the 88 cases, 13 were positive for cysts, 16 for emphysema, 8 for nodules, 8 for GGNs (ground glass nodules), 13 for mediastinal masses, 20 for scoliosis, 44 for subcutaneous nodules, and 34 for skin nodules. Cysts showed upper and peripheral dominant distributions. Regarding 13 mediastinal masses, 2 were diagnosed as malignant peripheral nerve sheath tumors (MPNSTs), 1 was diagnosed as primary lung cancer, 2 were diagnosed as lateral meningocele, 3 were diagnosed as neurofibromas, and the remaining 7 were considered neurofibromas. There was a significant correlation between the prevalence of subcutaneous nodules and that of skin nodules. Significant positive correlations were also seen between size and number, size and rate of central distribution, and number and rate of central distribution of cysts. Conclusion: Various CT findings were found in NF-1 patients, and the prevalence rates of subcutaneous and skin nodules were higher than other findings. Though the prevalence rates of subcutaneous nodules and skin nodules were significantly correlated, the other CT findings in NF-1 occurred independently. The number, size, and

  20. Characteristic MR and CT imaging findings of hepatobiliary paragonimiasis and their pathologic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chunyan; Hu, Yajun; Chen, Weixia [Dept of Radiology, West China Hospital of Sichuan Univ., Sichuan (China)], e-mail: wxchen25@126.com

    2012-06-15

    Background: Hepatobiliary paragonimiasis (HP) is not commonly encountered and may be confused with hepatobiliary tumors; however, computed tomography (CT) and magnetic resonance imaging (MRI) features of HP allow this entity to be distinguished from other diseases. Purpose: To present the CT and MRI findings in patients with HP and to describe some specific imaging findings along with their pathological correlations. Material and Methods: Imaging and clinical findings of 21 patients (9 boys/men and 12 girls/women; age range 3-67 years; mean age 40 years) who were diagnosed with HP were retrospectively evaluated. Among these patients, 16 underwent CT examination only, two had MR examination only, and three underwent both CT and MR. All patients underwent surgery, and the HP diagnosis was confirmed by the surgical and histopathologic results. Results: Chronic abdominal pain or back pain was reported by 14 patients, severe abdominal pain with acute onset was reported by one patient, and six patients were asymptomatic and were discovered incidentally. Peripheral eosinophilia was present in 14 patients (14/21, 66.7%), and abnormal liver function tests were found in 16 patients (16/21, 76.2%). Of the 19 patients who underwent CT imaging, 17 patients showed multiple mixed hypodense lesions or multiple cysts with inlaying septation with separate irregular rims or circular enhancement on post-contrast CT images. Tunnel-shaped micro abscesses and necrotic cavities were found in the lesions of 12 of those 17 patients. The other two patients showed smaller cystic masses. MRI showed faveolate T1 hypointense and T2 hyperintense areas in the liver parenchyma with rim or peripheral enhancement. Nodular or circular hyperintense materials were found scattered in the lesions on T1-weighted imaging. Conclusion: CT and MRI can reveal the radiological-pathological features of HP. Together with laboratory findings, MRI and CT findings may provide diagnostic clues, especially in endemic

  1. Evaluation of node involvement in non small cell bronchogenic carcinoma. CT-pathology correlation; Valutazione del fattore <> nel carcinoma polmonare non a piccole cellule. Correlazione tra tomografia computerizzata e anatomia patologica

    Energy Technology Data Exchange (ETDEWEB)

    Pirronti, T.; Macis, G.; Sallustio, G.; Minordi, L.M.; Marano, P. [Rome Univ. Cattolica del Sacro Cuore, Rome (Italy). Ist. di Radiologia; Granone, P. [Rome Univ. Cattolica del Sacro Cuore, Rome (Italy). Ist. di Patologia Chirurgica; Vecchio, F.M. [Rome Univ. Cattolica del Sacro Cuore, Rome (Italy). Ist. di Anatomia Patologica

    2000-05-01

    The main purpose of this work is to evaluate the role of CT in identifying other morphological signs of met static lymph node involvement from non small cell bronchogenic carcinoma. This is done to improve N staging, a critical step in this disease. In fact, since diameter is the only criterion used to distinguish normal form abnormal lymph nodes, mediastinal CT only has 80% diagnostic accuracy. 137 patients with known or suspected lung cancer were examined with Helical CT during early and late arterial phases (2 min. delay, 3 mm thickness, 5 mm inter slice gap) to depict node characteristics. Mediastinal lymph nodes, located according to the American Thoracic Society mapping, were considered normal when they were not visible or, if visible, less than 1 cm in diameter and of homogeneous density; lymph nodes over 1 cm in diameter and homogenous density were considered reactive. A lymph node was considered metastatic when, independent of size, the following signs were found: central hypo density; hyperdense thin/thick rim, with nodules within; hyperdense strands or diffuse hyper density in perinodal adipose tissue. The tumor site was also considered. Seventy patients were excluded because they were inoperable. Sixty-five of the remaining 67 patients were operated on, 1 underwent mediastinoscopy and another one mediastinoscopy followed by surgery. Based on above CT signs, 46 patients were staged as N0, 61 as N1 and 15 as N2. In 44/46 N0 patients there was agreement between anatomical and pathologic findings; 3 of the 44 patients had lymph nodes over 1 cm in diameter and with homogeneous density. Micrometastases to mediastinal lymph nodes (N2) were found at histology in 2/46 patients (CT false negatives). In the 6 N1 and the 15 N2 patients there was complete agreement between anatomical and pathologic findings; in particular, 9 N2 patients had lymph nodes less than 1 cm in diameter with signs of metastasis and 4 had lymph nodes over 1 cm in diameter with signs of

  2. CT detector evaluation with complex random backgrounds

    Science.gov (United States)

    Fan, Helen; Barrett, Harrison H.

    2012-02-01

    Modern computed tomography (CT) uses detector arrays consisting of large numbers of photodiodes with scintil- lator crystals. The number of pixels in the array can play an important role in system performance. Considerable research has been performed on signal detection in flat backgrounds under various conditions, but little has been done with complex, random backgrounds in CT; our work investigates in particular the effect of the number of detector elements on signal detection by a channelized Hotelling observer in a complex background. For this project, a simulated three-dimensional phantom is generated with its attenuation equal to that of water. The phantom contains a smaller central section with random variations to simulate random anatomical structures. Cone-beam projections of the phantom are acquired at different angles and used to calculate the covariance matrix of the raw projection data. Laguerre-Gauss channels are used to reduce the dimensionality of each 2D projection and hence the size of the covariance matrix, but the covariance is still a function of two projection angles. A strong cross-channel correlation is observed as a function of the difference between the angles. A signal with known location and size is used, and the performance of the observer is calculated from the channel outputs at multiple projection angles. A contrast-detail diagram is computed for different variables such as signal size, number of incident x-ray photons, pixel size, etc. At a fixed observer signal-to-noise ratio (SNR), the contrast required to detect a signal increases dramatically as the signal size decreases.

  3. An imaging diagnosis of cerebral paragonimiasis: CT and MR findings and correlation with ELISA antibody test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Hyun; Cha, Sang Hoon; Han, Moon Hee; Kim, Hong Dae; Cho, Seung Yull; Kong, Yoon; Kang, Hyung Keun; Kim, Myung Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    To evaluate the CT and MR findings of cerebral paragonimiasis(PW) and to assess the diagnostic value of the specific antibody test by enzyme-linked immunosorbent assay(ELISA) for PW, 55 CT scans and 13 MR images of 57 patients with cerebral PW were reviewed retrospectively, and correlated with the serum/ CSF antibody levels. We divided the patients into three groups, early active (n=21), chronic(n=32), and combined stage(n=4), on the basis of CT/MR findings. In the groups of early active stage the most common and characteristic finding was multiple, conglomerated, ring-like enhancing lesion in the unilateral cerebral hemisphere, which was seen in 52% on CT and 44% on MR. Other non-specific findings included a solitary ring-like or irregular enhancing lesions, ill-defined low density lesions without enhancement, localized hemorrhage with or without enhancing lesions. In the group of chronic stage, there were multiple calcifications of various shapes, most commonly 1-2 cm sized round shape, and associated encephalomalacia. MR was superior to CT in detecting hemorrhage and in characterizing the central contents of ring-shaped calcifications, while it was inferior to CT in identifying small calcifications. Antibody levels of serum and CSF were positive in 86% and 82% in early active group, and in 48% and 31% in chronic stage,retrospectively.The positive rate was significantly different between the two groups (P=0.001). CT/MR findings were characteristic in only approximately half the cases in early active cerebral PW which can be cured by Praziquantel therapy. Therefore, antibody test by ELISA is recommended as a complementary tool, particularly in patients with non-specific imaging findings.

  4. Correlating metabolic and anatomic responses of primary lung cancers to radiotherapy by combined F-18 FDG PET-CT imaging

    Directory of Open Access Journals (Sweden)

    Grills Inga

    2007-05-01

    Full Text Available Abstract Background To correlate the metabolic changes with size changes for tumor response by concomitant PET-CT evaluation of lung cancers after radiotherapy. Methods 36 patients were studied pre- and post-radiotherapy with18FDG PET-CT scans at a median interval of 71 days. All of the patients were followed clinically and radiographically after a mean period of 342 days for assessment of local control or failure rates. Change in size (sum of maximum orthogonal diameters was correlated with that of maximum standard uptake value (SUV of the primary lung cancer before and after conventional radiotherapy. Results There was a significant reduction in both SUV and size of the primary cancer after radiotherapy (p Conclusion Correlating and incorporating metabolic change by PET into size change by concomitant CT is more sensitive in assessing therapeutic response than CT alone.

  5. CT muscle scanning in the evaluation of patients with spinal muscular atrophy (SMA)

    Energy Technology Data Exchange (ETDEWEB)

    Sambrook, P.; Rickards, D.; Cumming, W.J.K.

    1988-12-01

    One hundred with spinal muscular atrophy (SMA) were assessed by CT scanning using a standardised technique. The spectrum of CT abnormality occurring in SMA was observed and by overall analysis the patients were divided into 4 groups. While the CT appearances of these groups correlated well with clinical assessment of severity of disease, the disease process was usually much more widespread than clinical examination suggested. CT abnormality was first observed in the leg and gluteal muscles, progressing to the posterior spinal, thigh, shoulder girdle and sternomastoid muscles. Hypertrophy of sartorius and gracilis was observed in a significant number of patients. Fascial planes were preserved in involved muscles in over half of the patients, even in late-stage disease. Asymmetrical muscle involvement was seen with increasing frequency as the disease process increased in extent as evaluated by CT scanning. There was no discernible difference in the CT appearances in those patients who clinically had limb-girdle, facioscapulohumeral or scapuloperoneal distribution of weakness.

  6. Evaluation of periventricular radiolucency in hydrocephalus by dynamic CT studies

    Energy Technology Data Exchange (ETDEWEB)

    Nakano, Hideki; Bandou, Kuniaki; Miyaoka, Makoto (Fujisawa City Hospital, Kanagawa (Japan))

    1994-06-01

    The association of periventricular radiolucency (PVL) in normal pressure hydrocephalus (NPH) on CT scan is a common finding. However, it is difficult to differentiate NPH from atrophy or infarctions in which shunt surgery does not reverse these conditions. To distinguish NPH from these, we examined PVL by means of dynamic CT (DCT) studies. We investigated 12 elderly patients presenting with gait disturbance, urinary incontinence and mental dysfunction who had both enlarged lateral ventricles and PVL. All patients had laboratory investigations, including radioisotope and CT cisternography and Xenon CBF studies. Nine patients were shunted because of abnormal CSF dynamics. Varying degrees of clinical improvement after surgery were observed in 6 cases. A difference of arrival time (AT) between PVL and thalamus obtained from time-density-curve was calculated in each patient. The AT difference was 6.2[+-]1.5 sec. in the shunt-effective group, and 1.4[+-]1.3 sec. in both, the shunt in effective and ineligible group, this was highly significant (p<0.01). We also measured peak time (PT) in PVL, of the thalamus and anterior cerebral artery, but no significant correlation was obtained. An AT difference between PVL and thalamus obtained from DCT studies is a clinically useful diagnostic tool for the evaluation of NPH. (author).

  7. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nyflot, Matthew J., E-mail: nyflot@uw.edu [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195-6043 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195-6043 (United States); Alessio, Adam M.; Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195-6043 (United States); Wollenweber, Scott D.; Stearns, Charles W. [GE Healthcare, Waukesha, Wisconsin 53188 (United States); Bowen, Stephen R. [Department of Radiation Oncology, University of Washington, Seattle, Washington 98195-6043 and Department of Radiology, University of Washington, Seattle, Washington 98195-6043 (United States)

    2015-01-15

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by

  8. Clinical evaluation of CT and radionuclide examination in renal diseases

    Energy Technology Data Exchange (ETDEWEB)

    Kutani, W.; Ishida, H.; Shirakawa, S.; Shintaku, T.; Funaki, R. (Osaka Medical Coll., Takatsuki (Japan))

    1980-08-01

    One hundred and twelve cases of renal diseases were studied by computed tomography (CT) using EMI 5005/12. Of them, 60 were examined by both CT and renal scintigraphy, and comparatively evaluated. The CT units were checked before and after the contrast enhancement. Renal scintigrams were obtained by gamma cameras (PHO/GAMMA HP 6406, PHO/GAMMA LFOV) using 99 M Tc-DMSA. CT was especially useful in diagnosing the renal cysts and the hydronephrosis. Cysts in other organs (liver, spleen and pancreas) were simultaneously ascertained in polycystic diseases. CT was not helpful in diagnosing nephritis and diabetic nephropathy. Floating kidney and horse-shoe kidney were difficult to diagnose with CT. The renal scintigram was the reflection of the renal function, and was relatively more useful than CT in diagnosing horse-shoe kidney, floating kidney and nephritis, while it was not useful for non-functioning kidneys.

  9. Thin-section CT imaging that correlates with pulmonary function tests in obstructive airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki, E-mail: arakawa@dokkyomed.ac.jp [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan); Fujimoto, Kiminori [Department of Radiology, Kurume University School of Medicine (Japan); Fukushima, Yasutugu [Department of Pulmonary Medicine and Clinical Immunology, Dokkyo Medical University (Japan); Kaji, Yasushi [Department of Radiology, Dokkyo Medical University, 880 Kita-Kobayashi, Mibu, Tochigi 321-0293 (Japan)

    2011-11-15

    Purpose: The purpose of this study was to identify independent CT findings that correlated with pulmonary function tests (PFTs) in patients with obstructive airway diseases. Materials and methods: Sixty-eight patients with obstructive airway disease and 29 normal subjects (mean age, 52 years; 36 men and 61 women) underwent inspiratory and expiratory thin-section CT and PFTs. Patient with obvious emphysema was excluded. Two radiologists independently reviewed the images and semi-quantitatively evaluated lung attenuation (mosaic perfusion, air trapping) and airway abnormalities (extent and severity of bronchial wall thickening and bronchiectasis, bronchiolectasis or centrilobular nodules, mucous plugging). Univariate, multivariate and receiver operating characteristic (ROC) analyses were performed with CT findings and PFTs. Results: Forty-two patients showed obstructive PFTs, 26 symptomatic patients showed near-normal PFTs. On univariate analysis, air trapping and bronchial wall thickening showed highest correlation with obstructive PFTs such as FEV1.0/FVC, MMEF and FEF75 (r ranged from -0.712 to -0.782; p < 0.001), while mosaic perfusion and mucous plugging showed moderate correlation, and bronchiectasis, bronchiolectasis and nodules showed the least, but significant, correlation. Multiple logistic analyses revealed air trapping and bronchial wall thickening as the only significant independent determinants of obstructive PFTs. ROC analysis revealed the cut-off value of air trapping for obstructive PFTs to be one-third of whole lung (area under curve, 0.847). Conclusions: Our study confirmed air trapping and bronchial wall thickening are the most important observations when imaging obstructive PFTs. The cut-off value of air trapping for identifying obstructive PFTs was one-third of lung irrespective of inspiratory CT findings.

  10. Correlation between the Quantifiable Parameters of Whole Solitary Pulmonary Nodules Perfusion Imaging Derived with Dynamic CT and Nodules Size

    Directory of Open Access Journals (Sweden)

    Shiyuan LIU

    2009-05-01

    Full Text Available Background and objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. The blood flow patterns of the biggest single SPNs level has been studied. This assessment may be only a limited sample of the entire region of interest (ROI and is unrepresentative of the SPNs as a volume. Ideally, SPNs volume perfusion should be measured. The aim of this study is to evaluate the correlation between the quantifiableparameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size. Methods Sixty-five patients with SPNs (diameter≤3 cm; 42 malignant; 12 active inflammatory; 11 benign underwent multi-location dynamic contrast material-enhanced serial CT scanning mode with stable table were performed; The mean values of valid sections were calculated, as the quantifiable parameters of volume SPNs perfusion imaging derived with16-slice spiral CT and 64-slice spiral CT. The correlation between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size were assessed by means of linear regression analysis. Results No significant correlations were found between the nodules size and each of the peak height (PHSPN (32.15 Hu±14.55 Hu,ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio(13.20±6.18%, perfusion(PSPN (29.79±19.12 mLmin-1100 g-1 and mean transit time (12.95±6.53 s (r =0.081, P =0.419; r =0.089, P =0.487; r =0.167, P =0.077; r =0.023, P =0.880. Conclusion No significant correlations were found between the quantifiable parameters of SPNs volume perfusion imaging derived with 16-slice spiral CT and 64-slice spiral CT and nodules size.

  11. Sequential change of fibrosing alveolitis on high-resolution CT: correlation with finding at pulmonary function test and bronchoalveolar lavage

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Soo; Kim, Yang Hee; Kim, Sae Hun [College of Medicine, Soonchunhyang University, Seoul (Korea, Republic of)] (and others)

    1995-08-15

    To evaluate prospectively relationship between the extent of abnormalities of fibrosing alveolotro on high resolution CT and these of pulmonary function test, and bronchoalveolar lavage. This study included 27 patients with pathologically proved UIP. We prospectively analyzed correlation of the extent of ground glass opacity, consolidation, irregular lines with honeycombing on initial CT scan and quantitative change of ground glass opacity on follow up CT scans with pulmonary function test(PFT) and bronchoalveolar lavage(BAL). On initial CT scan, score of extent of disease significantly correlated with FEV1(r = -0.5148, {rho} = 0.0310) and DLco(r -0.7102, {rho} = 0.0001). Proportion of individual cell in BAL was not correlated with ground glass opacity or extent of disease; lymphocyte({rho} -0.0165, r = 0.9616), eosinophil ({rho} = -0.0077, r = 0.9832), neutrophil ({rho} = -0.1732, r = 0.5903). On follow up CT scan, quantitative change of ground glass opacity correlated with DLco/VA(r = -0.6825, {rho} = 0.0025) and TLC (r = 0.5248, {rho} = 0.0429). The quantitative analysis of extent of disease on HRCT in useful for evaluation of clinical status. Also change of ground glass opacity on follow-up HRCT significantly correlated with improvement of diffusing capacity in fibrosing alveolitis.

  12. Correlation between human observer performance and model observer performance in differential phase contrast CT

    Energy Technology Data Exchange (ETDEWEB)

    Li, Ke; Garrett, John [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Chen, Guang-Hong [Department of Medical Physics, University of Wisconsin-Madison, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison, 600 Highland Avenue, Madison, Wisconsin 53792 (United States)

    2013-11-15

    Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objects (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD

  13. CT evaluation of thoracic infections after major trauma

    Energy Technology Data Exchange (ETDEWEB)

    Mirvis, S.E.; Rodriguez, A.; Whitley, N.O.; Tarr, R.J.

    1985-06-01

    Thirty-seven septic patients with major multisystem trauma were evaluated by computed tomography (CT) to identify possible thoracic sources of infection. CT was 72% accurate in the diagnosis of empyema and 95% accurate in the diagnosis of lung abscess. While CT proved useful in demonstrating these sites of thoracic infections in septic trauma victims, the presence of concurrent thoracic pathology, particularly loculated hemothorax or hemopneumothorax and traumatic lung cysts with hemorrhage or surrounding parenchymal consolidation, introduced sources of diagnostic error. CT also proved helpful in guiding appropriate revisions of malpositioned and occluded thoracostomy tubes.

  14. Improved correlation between CT emphysema quantification and pulmonary function test by density correction of volumetric CT data based on air and aortic density

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Song Soo [Department of Radiology, Chungnam National University Hospital, Chungnam National University School of Medicine (Korea, Republic of); Seo, Joon Beom, E-mail: seojb@amc.seoul.kr [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Kim, Namkug; Chae, Eun Jin [Department of Radiology, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of); Lee, Young Kyung [Department of Radiology, Kyung Hee University Hospital at Gangdong (Korea, Republic of); Oh, Yeon Mok; Lee, Sang Do [Division of Pulmonology, Department of Internal Medicine, University of Ulsan College of Medicine, Asan Medical Center (Korea, Republic of)

    2014-01-15

    Objectives: To determine the improvement of emphysema quantification with density correction and to determine the optimal site to use for air density correction on volumetric computed tomography (CT). Methods: Seventy-eight CT scans of COPD patients (GOLD II–IV, smoking history 39.2 ± 25.3 pack-years) were obtained from several single-vendor 16-MDCT scanners. After density measurement of aorta, tracheal- and external air, volumetric CT density correction was conducted (two reference values: air, −1000 HU/blood, +50 HU). Using in-house software, emphysema index (EI) and mean lung density (MLD) were calculated. Differences in air densities, MLD and EI prior to and after density correction were evaluated (paired t-test). Correlation between those parameters and FEV{sub 1} and FEV{sub 1}/FVC were compared (age- and sex adjusted partial correlation analysis). Results: Measured densities (HU) of tracheal- and external air differed significantly (−990 ± 14, −1016 ± 9, P < 0.001). MLD and EI on original CT data, after density correction using tracheal- and external air also differed significantly (MLD: −874.9 ± 27.6 vs. −882.3 ± 24.9 vs. −860.5 ± 26.6; EI: 16.8 ± 13.4 vs. 21.1 ± 14.5 vs. 9.7 ± 10.5, respectively, P < 0.001). The correlation coefficients between CT quantification indices and FEV{sub 1}, and FEV{sub 1}/FVC increased after density correction. The tracheal air correction showed better results than the external air correction. Conclusion: Density correction of volumetric CT data can improve correlations of emphysema quantification and PFT.

  15. Proton MRI in the evaluation of pulmonary sarcoidosis: Comparison to chest CT

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jonathan H., E-mail: chungj@njhealth.org [Radiology, National Jewish Health, Denver, CO (United States); Little, Brent P., E-mail: bplittle2@hotmail.com [Radiology, Emory University School of Medicine, Atlanta, GA (United States); Forssen, Anna V., E-mail: ForssenA@NJHealth.org [Division of Biostatistics and Bioinformatics, National Jewish Health, Denver, CO (United States); Yong, Jin, E-mail: JinG@NJHealth.org [Radiology, National Jewish Health, Denver, CO (United States); Diagnostic Radiology, Chonbuk National University Medical School, Jeonbuk (Korea, Republic of); Nambu, Atsushi, E-mail: nambu-a@gray.plala.or.jp [Radiology, National Jewish Health, Denver, CO (United States); Radiology, University of Yamanashi, Chuo City (Japan); Kazlouski, Demitry, E-mail: demitry.kazlouski@gmail.com [Radiology, National Jewish Health, Denver, CO (United States); Puderbach, Michael, E-mail: m.puderbach@dkfz-heidelberg.de [Diagnostic and Interventional Radiology, Chest Clinics at University Hospital, Heidelberg (Germany); Biederer, Juergen, E-mail: juergen.biederer@uni-heidelberg.de [Diagnostic and Interventional Radiology, Heidelberg University Hospital, Heidelberg (Germany); Lynch, David A., E-mail: LynchD@NJHealth.org [Radiology, National Jewish Health, Denver, CO (United States)

    2013-12-01

    Purpose: The purpose of this study was to determine the feasibility of proton MRI of the lung in sarcoidosis patients and the agreement between the imaging appearance of pulmonary sarcoidosis on MRI and CT. Materials and methods: Chest CT scans and dedicated pulmonary MRI scans (including HASTE, VIBE, and TrueFISP sequences) were performed within 90 days of each other in 29 patients. The scans were scored for gross parenchymal opacification, reticulation, nodules, and masses using a 3-point lobar scale. Total and subset scores for corresponding MRI and CT scans were compared using the Spearman correlation test, Bland–Altman plots, and Cohen's quadratic-weighted kappa analysis. MRI scores were compared to CT by lobe and disease category, using percentage agreement, Spearman rank correlation, and Cohen's quadratic-weighted kappa. Results: The mean (±s.d.) time between MRI and CT scans was 33 ± 32 days. There was substantial correlation and agreement between total disease scoring on MRI and CT with a Spearman correlation coefficient of 0.774 (p < 0.0001) and a Cohen's weighted kappa score of 0.646. Correlation and agreement were highest for gross parenchymal opacification (0.695, 0.528) and reticulation (0.609, 0.445), and lowest in the setting of nodules (0.501, 0.305). Agreement testing was not performed for mass scores due to low prevalence. Upper lobe scoring on MRI and CT demonstrated greater agreement compared to the lower lobes (average difference in Cohen's weighted kappa score of 0.112). Conclusion: There is substantial correlation and agreement between MRI and CT in the scoring of pulmonary sarcoidosis, though MRI evaluation in the upper lobes may be more accurate than in the lower lobes.

  16. CT findings in cerebral palsy - An attempt at clinico-radiological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyo Keun; Lee, Kil Woo; Choo, In Wook; Kim, Mee Kang; Bae, Sang Hoon [Hallym University College of Medicine, Seoul (Korea, Republic of); Lee, Mun Gyu [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    CT scans of one hundred-three children with cerebral palsy were analyzed retrospectively and correlated with various clinical assessment. Incidence of pathologic CT scans was 71% and most common pathology was brain atrophy (45%). Other pathology consisted of brain anomaly (13%), infarction (11%), hydrocephalus (6%), porencephalic cyst (6%), diffuse periventricular low density (5%) and pathologic calcification (4%). No statistically significant correlation could be found between the types of cerebral palsy and incidence of pathologic CT findings. Higher incidence of pathologic CT scans could be shown in the group that physical handicap was severe and etiological factor was prenatal or postnatal and in the patients with seizure.

  17. Tracheal CT morphology: correlation with distribution and extent of thoracic adipose tissue

    Energy Technology Data Exchange (ETDEWEB)

    Ap Dafydd, Derfel [Imperial College Healthcare NHS Trust, Department of Radiology, Charing Cross Hospital, London (United Kingdom); Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, King' s College London, King' s Health Partners, London (United Kingdom); Gordon, Fabiana; Copley, Susan J. [Imperial College, London (United Kingdom)

    2016-10-15

    To evaluate the relationship between adipose tissue measurements and anterior bowing of the posterior tracheal wall in a large nonselected group of patients undergoing CT pulmonary angiography (CTPA). Consecutive patients undergoing CTPA over a 4-month period were analyzed retrospectively. Using an adapted scoring system (posterior bowing, flattening, mild/moderate or severe anterior bowing of the posterior tracheal membrane), the axial morphology and cross-sectional area of the trachea at the narrowest point and 1 cm above the aortic arch were evaluated. Measurements of adipose tissue were taken (anterior mediastinal fat width, sagittal upper abdominal diameter and subcutaneous fat thickness at the level of the costophrenic angle). Relationships between tracheal morphology and measurements of adipose tissue were analyzed. 296 patients were included (120 males, 176 females, mean age 59 years, range 19-90). Severe anterior bowing of the posterior tracheal wall correlated with increasing sagittal upper abdominal diameter (p = 0.002). Mild/moderate and severe anterior bowing of the posterior tracheal wall correlated with increasing mediastinal fat width (p = 0.000 and p = 0.031, respectively). Tracheal cross-sectional area was inversely correlated with increasing subcutaneous fat thickness (p = 0.022). The findings demonstrate a statistically significant relationship between CT tracheal morphology and adipose tissue measurements in a large nonselected population. (orig.)

  18. Glenohumeral position during CT arthrography with arthroscopic correlation: optimization of diagnostic yield

    Energy Technology Data Exchange (ETDEWEB)

    Simeone, F.J.; Gill, Corey M.; Torriani, Martin; Bredella, Miriam A. [Massachusetts General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Taneja, Atul K. [Hospital Israelita Albert Einstein, Hospital do Coracao (HCor) and Teleimagem, Musculoskeletal Imaging, Sao Paulo, SP (Brazil)

    2017-06-15

    To evaluate the diagnostic yield of two acquisitions of single-contrast CT arthrography (CTA) of the shoulder in internal, neutral, or external glenohumeral rotation with arthroscopic correlation. The CT study was obtained using two acquisitions (first the humerus positioned in maximum tolerated external rotation with the arm along the body and the second with the humerus in internal rotation with the palm placed flat on the table). Two independent readers blinded to the arthroscopic results evaluated the CTA images for labral tears, glenoid bone loss/fractures, and cartilage loss. For each CTA acquisition, sensitivity and specificity for detection of the aforementioned pathology were assessed. Inter-reader agreement was quantified by weighted k statistics. Sensitivity and specificity for detecting anteroinferior or posterior labral tears was highest with neutral rotation (sensitivity 91-100%, specificity 61-100%). For glenoid fracture, sensitivity (67%) was highest with external rotation and specificity (100%) was highest with internal rotation. For cartilage loss, sensitivity (64%) and specificity (89%) was highest with external rotation and neutral rotation, respectively. Neutral rotation showed high sensitivity and specificity for glenoid fractures and cartilage loss. Inter-reader agreement ranged from fair to very good. Neutral glenohumeral position in shoulder CT arthrography was adequately sensitive and specific for the detection of intra-articular pathology, avoiding the use of more than one acquisition. (orig.)

  19. Enhancement patterns of pancreatic adenocarcinoma on conventional dynamic multi-detector row CT: Correlation with angiogenesis and fibrosis

    Institute of Scientific and Technical Information of China (English)

    Yuki Hattori; Toshifumi Gabata; Osamu Matsui; Kentaro Mochizuki; Hirohisa Kitagawa; Masato Kayahara; Tetsuo Ohta; Yasuni Nakanuma

    2009-01-01

    AIM: To evaluate retrospectively the correlation between enhancement patterns on dynamic computed tomography (CT) and angiogenesis and fibrosis in pancreatic adenocarcinoma.METHODS: Twenty-three patients with pancreatic adenocarcinoma underwent dynamic CT and tumor resection. In addition to the absolute and relative enhanced value that was calculated by subtracting the attenuation value on pre-contrast from those on contrast-enhanced CT in each phase, we defined one parameter, "tumor-aorta enhancement ratio", which was calculated by dividing enhancement of pancreatic cancer by enhancement of abdominal aorta in each phase. These enhancement patterns were correlated with the level of vascular endothelial growth factor (VEGF), microvessel density (MVD), and extent of fibrosis.RESULTS: The absolute enhanced value in the arterial phase correlated with the level of VEGF and MVD (P = 0.047, P = 0.001). The relative enhanced value in arterial phase and tumor-aorta enhancement ratio (arterial) correlated with MVD (P = 0.003, P = 0.022). Tumor-aorta enhancement ratio (arterial) correlated negatively with the extent of fibrosis (P = 0.004). The tumors with greater MVD and higher expression of VEGF tended to show high enhancement in the arterial dominant phase. On the other hand, the tumors with a larger amount of fibrosis showed a negative correlation with the grade of enhancement during the arterial phase.CONCLUSION: Enhancement patterns on dynamic CT correlated with angiogenesis and may be modified by the extent of fibrosis.

  20. CT evaluation of a mycotic aneurysma

    Energy Technology Data Exchange (ETDEWEB)

    Loehr, E.; Serdarevic, M.; Beck, A.; Wendt, F.C.

    1986-03-01

    Examination and localisation of mycotic aneurysm of the femoral artery in the course of typhoid fever. The diagnosis was exclusively carried out by CT and not by angiography to lower the risk of examination because the patient was suffering from chronic lymphatic leukaemia.

  1. Disease activity in idiopathic pulmonary fibrosis: CT and pathologic correlation.

    Science.gov (United States)

    Müller, N L; Staples, C A; Miller, R R; Vedal, S; Thurlbeck, W M; Ostrow, D N

    1987-12-01

    Computed tomography (CT) scans were compared with pathologic determinants of disease activity in 12 patients with idiopathic pulmonary fibrosis. The theory was that intraalveolar and interstitial cellularity would result in areas of opacification of air spaces on CT scans. All patients underwent open lung biopsy, and disease activity was assessed with a pathologic grading system. Seven patients had mild disease activity, five had moderate to marked disease activity. Opacification of air spaces was patchy in distribution, predominantly peripheral, and seen better on 1.5-mm rather than 10-mm collimation scans. Disease activity on CT scans was graded independently from 0 to 3 based on the presence and relative density of the areas of air space consolidation compared with the surrounding parenchyma. The pathologic score was significantly greater in the patients with high CT scores than in those with low CT scores (P = .001). Five patients with marked disease activity and five of seven patients with mild disease activity were correctly identified. CT may be useful in the assessment of disease activity in idiopathic pulmonary fibrosis.

  2. Correlation between CT perfusion parameters and microvessel density and vascular endothelial growth factor in adrenal tumors.

    Directory of Open Access Journals (Sweden)

    Hai-yan Qin

    Full Text Available We evaluated the correlation between computed tomography (CT perfusion parameters and markers of angiogenesis in adrenal adenomas and non-adenomas to determine if perfusion CT can be used to distinguish between them. Thirty-four patients with pathologically-confirmed adrenal tumors (17 adenomas, 17 non-adenomas received CT perfusion imaging before surgery. CT perfusion parameters (blood flow [BF], blood volume [BV], mean transit time [MTT], and permeability surface area product [PS] were calculated. Tumor tissue sections were examined with immunohistochemical methods for vascular endothelial growth factor (VEGF expression and microvessel density (MVD. The mean age of the 34 patients was 43 years. The median BV was significantly higher in adenomas than in non-adenomas [12.3 ml/100 g, inter-quartile range (IQR: 10.4 to 16.5 ml/100 g vs. 8.8 ml/100 g, IQR: 3.3 to 9.4 ml/100 g, p=0.001]. Differences in BF, MTT, and PS parameter values between adenomas and non-adenomas were not significant (p>0.05. The mean MVD was significantly higher in adenomas compared to non-adenomas (98.5 ± 28.5 vs. 53.5 ± 27.0, p<0.0001. Adenomas also expressed significantly higher median VEGF than non-adenomas (65%, IQR: 50 to 79% vs. 45%, IQR: 35 to 67%, p=0.02. A moderately strong correlation between BF and VEGF (r=0.53, p=0.03 and between BV and MVD among adenomas (r=0.57, p=0.02 exist. Morphology, MVD, and VEGF expression in adenomas differ significantly from non-adenomas. Of the CT perfusion parameters examined, both BF and BV correlate with MVD, but only BF correlates with VEGF, and only in adenomas. The significant difference in BV suggests that BV may be used to differentiate adenomas from non-adenomas. However, the small difference in BV shows that it may only be possible to use BV to identify adenomas vs. non-adenomas at extreme BV values.

  3. An evaluation of cranial CT scanning in clinical psychiatry.

    Science.gov (United States)

    Colohan, H; O'Callaghan, E; Larkin, C; Waddington, J L

    1989-07-01

    From 6,300 psychiatric admissions over a 37 month period, all 54 patient referrals for CT were identified and their charts reviewed. CT influenced diagnosis, management or prognosis in 11.7 percent of patients scanned. There was poor correlation between organicity on CT scan and findings on physical examination, laboratory testing, EEG and psychological testing. The mental state examination was the single significant correlate of CT abnormality. We suggest that the use of a formalised mental state examination such as the Mini Mental State, in addition to the usual clinical assessment of mental state, may improve the accuracy of prediction of abnormality on CT scan. The introduction of X-ray computed tomography (CT) is recognised to be one of the most important innovations in the recent history of clinical medicine. In neurology the value of a non-invasive technique for examining the intracranial contents was quickly realised in the areas of diagnosis, particularly in the detection of vascular accidents and tumours. CT has also attained a significant place in psychiatry. In research studies, it has provided important information on schizophrenia, alcoholism and chronic organic reactions. The place of CT in clinical psychiatry is less clear. As its availability has increased, such scans are being requested with increasing frequency in psychiatric patients. Cranial CT is a highly sensitive diagnostic procedure which, when used unselectively, may result in the discovery of incidental findings. Until recently, a function of the psychiatrist in relation to diagnosis was to first seek to distinguish symptoms produced by organic pathology from those produced by functional illness.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Evaluation of CT-based SUV normalization

    Science.gov (United States)

    Devriese, Joke; Beels, Laurence; Maes, Alex; Van de Wiele, Christophe; Pottel, Hans

    2016-09-01

    The purpose of this study was to determine patients’ lean body mass (LBM) and lean tissue (LT) mass using a computed tomography (CT)-based method, and to compare standardized uptake value (SUV) normalized by these parameters to conventionally normalized SUVs. Head-to-toe positron emission tomography (PET)/CT examinations were retrospectively retrieved and semi-automatically segmented into tissue types based on thresholding of CT Hounsfield units (HU). The following HU ranges were used for determination of CT-estimated LBM and LT (LBMCT and LTCT):  -180 to  -7 for adipose tissue (AT), -6 to 142 for LT, and 143 to 3010 for bone tissue (BT). Formula-estimated LBMs were calculated using formulas of James (1976 Research on Obesity: a Report of the DHSS/MRC Group (London: HMSO)) and Janmahasatian et al (2005 Clin. Pharmacokinet. 44 1051-65), and body surface area (BSA) was calculated using the DuBois formula (Dubois and Dubois 1989 Nutrition 5 303-11). The CT segmentation method was validated by comparing total patient body weight (BW) to CT-estimated BW (BWCT). LBMCT was compared to formula-based estimates (LBMJames and LBMJanma). SUVs in two healthy reference tissues, liver and mediastinum, were normalized for the aforementioned parameters and compared to each other in terms of variability and dependence on normalization factors and BW. Comparison of actual BW to BWCT shows a non-significant difference of 0.8 kg. LBMJames estimates are significantly higher than LBMJanma with differences of 4.7 kg for female and 1.0 kg for male patients. Formula-based LBM estimates do not significantly differ from LBMCT, neither for men nor for women. The coefficient of variation (CV) of SUV normalized for LBMJames (SUVLBM-James) (12.3%) was significantly reduced in liver compared to SUVBW (15.4%). All SUV variances in mediastinum were significantly reduced (CVs were 11.1-12.2%) compared to SUVBW (15.5%), except SUVBSA (15.2%). Only SUVBW and SUVLBM-James show

  5. CT evaluation of primary epiphyseal bone abscesses

    Energy Technology Data Exchange (ETDEWEB)

    Azouz, E.M. (Dept. of Radiology, McGill Univ., Montreal Children' s Hospital, PQ (Canada)); Greenspan, A. (Dept. of Radiology, California Univ., Davis School of Medicine, Sacramento, CA (United States)); Marton, D. (Dept. of Radiology, Montreal Univ., Hopital Ste Justine, PQ (Canada))

    1993-01-01

    We reviewed the clinical, radiographic, and computed tomographic (CT) findings in eight children with a histologically proven diagnosis of epiphyseal or apophyseal osteomyelitis. In all cases the femur was involved: in five the osteomyelitis was localized in the femoral condyle, in two it was in the greater trochanter, and in one it was in the femoral head epiphysis. In four of the six cases of epiphyseal involvement there was associated joint effusion or septic arthritis. CT examination may demonstrate a serpentine tract, a sequestrum, cortical destruction or adjacent soft tissue swelling and can differentiate osteomyelitis from other epiphyseal lucent lesions, particularly chondroblastoma and osteoid osteoma. Early diagnosis helps avoid delays in initiating antibiotic or surgical treatment caused by the unusual (epiphyseal or apophyseal) location of the bone abscess. (orig./GD)

  6. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  7. Correlation analysis between pulmonary function test parameters and CT image parameters of emphysema

    Science.gov (United States)

    Liu, Cheng-Pei; Li, Chia-Chen; Yu, Chong-Jen; Chang, Yeun-Chung; Wang, Cheng-Yi; Yu, Wen-Kuang; Chen, Chung-Ming

    2016-03-01

    Conventionally, diagnosis and severity classification of Chronic Obstructive Pulmonary Disease (COPD) are usually based on the pulmonary function tests (PFTs). To reduce the need of PFT for the diagnosis of COPD, this paper proposes a correlation model between the lung CT images and the crucial index of the PFT, FEV1/FVC, a severity index of COPD distinguishing a normal subject from a COPD patient. A new lung CT image index, Mirage Index (MI), has been developed to describe the severity of COPD primarily with emphysema disease. Unlike conventional Pixel Index (PI) which takes into account all voxels with HU values less than -950, the proposed approach modeled these voxels by different sizes of bullae balls and defines MI as a weighted sum of the percentages of the bullae balls of different size classes and locations in a lung. For evaluation of the efficacy of the proposed model, 45 emphysema subjects of different severity were involved in this study. In comparison with the conventional index, PI, the correlation between MI and FEV1/FVC is -0.75+/-0.08, which substantially outperforms the correlation between PI and FEV1/FVC, i.e., -0.63+/-0.11. Moreover, we have shown that the emphysematous lesion areas constituted by small bullae balls are basically irrelevant to FEV1/FVC. The statistical analysis and special case study results show that MI can offer better assessment in different analyses.

  8. CT of lumbar spine disk herniation: correlation with surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Firooznia, H.; Benjamin, V.; Kricheff, I.I.; Rafii, M.; Golimbu, C.

    1984-03-01

    Computed tomography (CT) of the lumbar spine was performed with selectively positioned 5-mm-thick axial cross sections to examine each disk level from the top of the neural foramen to the pedicle of the next caudad vertebra. One hundred consecutive patients with 116 surgical disk explorations were reviewed. There was agreement between the CT and surgical findings in 89 patients (104 explorations) in determination of presence or absence of a herniated nucleus pulposus (HNP). Discrepancy occurred in 12 instances (11 patients): two because of incorrect interpretations, five in previously operated patients, three in spondylolisthesis, and two in spinal stenosis. There were 97 true-positives, eight false-negatives, seven true-negatives, and four false-positives. If nine previously operated patients are excluded from the study, then CT was accurate in detection of presence or absence of an HNP in 93% of the disk explorations.

  9. Small bowel adenocarcinoma in Crohn disease: CT-enterography features with pathological correlation.

    Science.gov (United States)

    Soyer, Philippe; Hristova, Lora; Boudghène, Frank; Hoeffel, Christine; Dray, Xavier; Laurent, Valérie; Fishman, Elliot K; Boudiaf, Mourad

    2012-06-01

    The aim of this study was to analyze the clinical, pathological, and CT-enterography findings of small bowel adenocarcinomas in Crohn disease patients. Clinical, histopathological, and imaging findings were retrospectively evaluated in seven Crohn disease patients with small bowel adenocarcinoma. CT-enterography examinations were reviewed for morphologic features and location of tumor, presence of stratification, luminal stenosis, proximal dilatation, adjacent lymph nodes, and correlated with findings at histological examination. The tumor was located in the terminal (n = 6) or distal (n = 1) ileum. On CT-enterography, the tumor was visible in five patients, whereas two patients had no visible tumor. Four different patterns were individualized including small bowel mass (n = 2), long stenosis with heterogeneous submucosal layer (n = 2), short and severe stenosis with proximal small bowel dilatation (n = 2), and sacculated small bowel loop with irregular and asymmetric circumferential thickening (n = 1). Stratification, fat stranding, and comb sign were present in two, two, and one patients, respectively. Identification of a mass being clearly visible suggests strongly the presence of small bowel adenocarcinoma in Crohn disease patients but adenocarcinoma may be completely indistinguishable from benign fibrotic or acute inflammatory stricture. Knowledge of these findings is critical to help suggest the diagnosis of this rare but severe complication of Crohn disease.

  10. CT saber-sheath trachea. Correlation with clinical, chest radiographic and functional findings

    Energy Technology Data Exchange (ETDEWEB)

    Trigaux, J.P. (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium)); Hermes, G. (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium)); Dubois, P. (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium)); Beers, B. van (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium)); Delaunois, L. (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium)); Jamart, J. (Services de Radiologie, de Pneumologie, Cliniques Universitaires UCL Mont-Godinne, Yvoir (Belgium))

    1994-05-01

    The diagnosis of saber-sheath trachea is easy at CT due to its cross-sectional imaging, but the significance of this CT sign has not been evaluated in the diagnosis of chronic obstructive pulmonary disease (COPD). Various signs of COPD were compared between a series of 20 patients with a saber-sheath trachea at CT (tracheal index [<=]66%) and a group of 20 pneumologic control patients without saber-sheath trachea (tracheal index [>=]70%). These signs include clinical and standard radiographic indices of COPD, sternum-spine distance and 3 functional tests of COPD: forced expiratory volume in one second, carbon monoxide diffusing lung capacity, and funtional residual capacity (FRC). A significant difference was found between the 2 groups, concerning the values of FRC and of sternum-spine distance (p<10[sup -2]). The tracheal index was significantly correlated with the FRC values and with the sternum-spine distance. No other significant difference was observed. It is concluded that saber-sheath trachea is basically a sign of hyperinflation. (orig./MG).

  11. Comparison of Haller index values calculated with chest radiographs versus CT for pectus excavatum evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Khanna, Geetika; Jaju, Alok; Don, Steven; Hildebolt, Charles F. [Washington University School of Medicine, Mallinckrodt Institute of Radiology, St. Louis, MO (United States); Keys, Tim [Medical Physics Services Ltd., St Louis, MO (United States)

    2010-11-15

    Pectus excavatum is a common chest wall anomaly in children. Pre-operative imaging for pectus excavatum is performed with CT, which is used to calculate the Haller index to determine the severity of pectus excavatum. To determine the correlation between Haller index values calculated with two-view chest radiographs and those calculated with CT and to determine, with CT as the reference standard, the diagnostic performance of radiographic Haller index for identifying cases that meet imaging criteria for surgical correction of pectus excavatum. For the period 2001-2009, our radiology information system was searched to identify all children who had undergone CT for Haller index calculation. Children who had also undergone two-view chest radiography (CXR) within 6 months of the CT were included in this retrospective study. Two radiologists independently calculated CT Haller index and radiographic Haller index. Data distributions were tested for normality with the Shapiro-Wilk W test. The associations between CT Haller index and radiographic Haller index were determined with the Spearman coefficient of rank correlation. Differences between CT Haller index and radiographic Haller index were tested with the Wilcoxon signed rank test. Haller index values were dichotomized into positive (>3.2) and negative ({<=}3.2) cases. Using CT as the reference standard, the sensitivity, specificity, and accuracy of radiographic Haller index in identifying children who meet imaging criteria for surgery were calculated. CT and CXR for evaluation of pectus excavatum were available for 32 children (25 male; median age 14.5 years). With CT, the median Haller indices for observers 1 and 2 were 3.4 and 3.5 and with CXR 3.5 and 3.5. There were statistically significant correlations between the radiographic Haller index and CT Haller index estimated by the two observers [Spearman correlation coefficient (95% confidence interval) for observer 1 = 0.71 (0.48-0.85, P < 0.01) and for observer 2 = 0

  12. Colorectal carcinoma evaluated by incremental dynamic CT; Comparison of CT density, histology, and tumor size

    Energy Technology Data Exchange (ETDEWEB)

    Furukawa, Hiroyoshi; Hara, Tsuyoshi; Taniguchi, Tetsushi (Shimizu Kosei Hospital, Shizuoka (Japan))

    1992-06-01

    Evaluation of incremental dynamic CT scan and histologic findings were compared in order to clarify the cause of the differences in colorectal carcinoma as observed on CT after administration of contrast medium. In 48 cases demonstrated on postcontrast dynamic CT scan, the CT density of the tumor was homogeneous (Type 1) in 26 (54.2%) cases and heterogeneous (Type 2) in 22 (45.8%) cases. Well differentiated adenocarcinoma was seen as Type 1 in 11 of 13 (84.6%) cases while moderately differentiated adenocarcinoma was of Type 1 in 15 of 29 (51.7%) cases. Poorly differentiated and mucinous adenocarcinoma were detected as Type 2 in all cases. A comparison of CT types and tumor size showed that as tumor size increased, the number of Type 1 cases decreased while Type 2 cases increased. Histologically, high density areas consisted mainly of well-developed tubular, branching glands of adenocarcinoma, while low density areas were composed of fibrous or mucinous stroma or necrosis. Dynamic CT scans for colorectal cancer are useful not only for preoperative staging but also for tissue characterization. (author).

  13. CT anatomy of the vagus nerve with radiological-pathological correlation of the intrathoracic vagal neurogenic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Miyagawa, Hideo [Nagoya City Univ. (Japan). Medical School

    2000-11-01

    The correlation in the title was evaluated since vagus nerve in the thoracic cavity had not been assessed by CT hitherto. For the purpose to examine the nerve imaging, subjects were a patient of neurofibromatosis and a normal volunteer. CT was done with Siemens Somato Plus 4 and General Electric-Yokokawa HiSpeed Advantage SG. For the same purpose, 100 cases of thoracic image by the latter apparatus were retrospectively assessed. Finally, the correlation in the title was examined retrospectively with combination of MR imaging in 9 cases who had undergone a surgery treatment of vagal neurogenic tumors (4 malignant and 4 benign cases of schwannoma and 1 neurofibromatosis). The nerve was found to be imaged by the ordinary CT and thus, which was thought to be useful for surgery, prognosis assessment and diagnosis of neurogenic tumors together with MRI. (K.H.)

  14. Experimental bacterial meningitis in rabbit; evaluation with CT and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jeong Jin; Kang, Heoung Keun; Chu, Sung Nam; Kim, Yun Hyeon; Jeong, Yong Yeon; Chung, Hyon De [Chonnam Univ. Medical School, Kwangju (Korea, Republic of)

    1996-01-01

    The purpose of this study was to evaluate the usefulness of computed tomography(CT) and magnetic resonance imaging(MRI) in experimental bacterial meningitis. CT and MR images of experimental bacterial meningitis were obtained after inoculation of 1ml suspension of 10-6/ml Staphylococcus aureus directly into the supratentorial arachnoid space of 18 New Zealand white rabbits. Each animal was studied with both pre-enhanced and post-enhanced CT and MRI at 12, 24, 48 hours and 1 week. Cerebrospinal fluid of all of 18 rabbits were sampled and cultured for bacterial growth. All of 18 rabbits had the clinical symptoms such as neck stiffness and anorexia within 24 hours after the inoculation. Cerebrospinal fluid cultures were positive for Staphylococcus aureus growth. Gd-enhanced MRI exhibited diffuse enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement along the thickened supratentorial meninges earlier than CT. In Gd-enhanced MRI, the mean contrast enhancement ratio(CER) at supratentorial meninges increased to 1.93 at 12 hours and 2.99 at 24 hours from 1.06 at 0 hour. Histologic evaluation demonstrated inflammatory cell infiltration into the meninges. MRI also identified the complications of meningitis such as ependymitis and hydrocephalus more effectively than CT. These results indicated that Fd-enhanced MRI detectred earlier the abnormal findingfs of bacterial meningitis and evaluated more effectively the complications of meningitis compared with CT. MRI was more useful than CT in evaluation of the bacterial meningitis.

  15. Evaluation of temporal bone pneumatization on high resolution CT (HRCT) measurements of the temporal bone in normal and otitis media group and their correlation to measurements of internal auditory meatus, vestibular or cochlear aqueduct

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Miyako

    1988-07-01

    High resolution CT axial scans were made at the three levels of the temoral bone 91 cases. These cases consisted of 109 sides of normal pneumatization (NR group) and 73 of poor pneumatization resulted by chronic otitis (OM group). NR group included sensorineural hearing loss cases and/or sudden deafness on the side. Three levels of continuous slicing were chosen at the internal auditory meatus, the vestibular and the cochlear aqueduct, respectively. In each slice two sagittal and two horizontal measurements were done on the outer contour of the temporal bone. At the proper level, diameter as well as length of the internal acoustic meatus, the vestibular or the cochlear aqueduct were measured. Measurements of the temporal bone showed statistically significant difference between NR and OM groups. Correlation of both diameter and length of the internal auditory meatus to the temporal bone measurements were statistically significant. Neither of measurements on the vestibular or the cochlear aqueduct showed any significant correlation to that of the temporal bone.

  16. CT differentiation between tubo-ovarian and appendiceal origin of right lower quadrant abscess: CT, clinical, and laboratory correlation.

    Science.gov (United States)

    Hiller, Nurith; Fux, Tal; Finkelstein, Anna; Mezeh, Haggi; Simanovsky, Natalia

    2016-04-01

    To investigate which clinical, laboratory, and CT findings potentially facilitate the differential diagnosis between tubo-ovarian abscess (TOA) and periappendicular abscess (PAA), we retrospectively reviewed abdominal CT examinations and medical records for all women who presented to our medical center with unilateral right pelvic abscess formation who underwent CT evaluation from 2004-2014. A wide spectrum of clinical data and imaging findings were recorded. CT diagnoses were made in consensus by two experienced body radiologists blinded to the final diagnosis. Findings associated with the infections were compared using the chi-square (χ(2)) or the Fisher exact test. Ninety-one patients were included; 58 with PAA (mean age 46 years) and 33 with TOA (mean age 37 years). Pain on cervical motion (67 %) and vaginal discharge (21 %) were significantly more common in TOA; other clinical signs were similar. The presence of right ovarian vein entering the mass on CT had 100 % specificity and 94 % sensitivity to TOA. Distended right fallopian tube (79 %), mass posterior to mesovarium (76 %), contralateral pelvic fat stranding (55 %), and thickening of sacrouterine ligaments (55 %) were significantly more common in TOA. Positive "arrowhead sign" (91 %), mesenteric lymphadenopathy (85 %), small bowel wall thickening (55 %), fluid in the right paracolic gutter (50 %), and cecal wall thickening (48 %) were significantly more common in PAA;internal gas was revealed only in PAA (33 %). Distinct CT features can increase diagnostic certainty regarding the origin of right lower quadrant abscess in women.

  17. CT evaluation of the damaged upper limb muscle in patients with Duchenne type progressive muscular dystrophy (DMD)

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Hiroshi (Anan Central Hospital, Tokushima (Japan)); Matsuke, Yutaka

    1992-04-01

    In order to evaluate the changes of CT numbers and cross sectional areas of the muscles, we determined CT scores of the muscle. In twelve patients with Duchenne type progressive muscular dystrophy (DMD), we assessed the difference of CT scores of the muscle and the correlation between CT score of the muscle and 9-stage classification of upper extremities. CT scores of the subscapularis muscle and infraspinatus muscle were significantly lower than deltoideus muscle at the level of the shoulder, and flexor muscles showed also significantly lower than extensor muscles at the level of the upper extremity. Good correlations between CT score of the muscle and 9-stage classification of upper extremities were observed in the muscles of shoulder and upper arm. (author).

  18. Cirrhosis: CT and MR imaging evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Brancatelli, Giuseppe [Sezione di Radiologia, Ospedale Specializzato in Gastroenterologia, ' Saverio de Bellis' -IRCCS, 70013 Castellana Grotte (Bari) (Italy) and Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy) and Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States)]. E-mail: gbranca@yahoo.com; Federle, Michael P. [Department of Radiology, University of Pittsburgh Medical Center, 200 Lothrop Street, 15213 Pittsburgh, PA (United States); Ambrosini, Roberta [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Lagalla, Roberto [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Carriero, Alessandro [Department of Diagnostic and Interventional Radiology, ' Maggiore della Carita' University Hospital, ' A.Avogadro' Eastern Piemonte University, Corso Mazzini 18, Novara (Italy); Midiri, Massimo [Sezione di Scienze Radiologiche, Dipartimento di Biotecnologie Mediche e Medicina Legale, Universita di Palermo, Via del Vespro 127, 90127 Palermo (Italy); Vilgrain, Valerie [Service de Radiologie, Hopital Beaujon, 100 Boulevard du General Leclerc, 92118 Clichy (France)

    2007-01-15

    In this article, we present the CT and MR imaging characteristics of the cirrhotic liver. We describe the altered liver morphology in different forms of viral, alcoholic and autoimmune end-stage liver disease. We present the spectrum of imaging findings in portal hypertension, such as splenomegaly, ascites and varices. We describe the patchy and lacelike patterns of fibrosis, along with the focal confluent form. The process of hepatocarcinogenesis is detailed, from regenerative to dysplastic nodules to overt hepatocellular carcinoma. Different types of non-neoplastic focal liver lesions occurring in the cirrhotic liver are discussed, including arterially enhancing nodules, hemangiomas and peribiliary cysts. We show different conditions causing liver morphology changes that can mimic cirrhosis, such as congenital hepatic fibrosis, 'pseudo-cirrhosis' due to breast metastases treated with chemotherapy, Budd-Chiari syndrome, sarcoidosis and cavernous transformation of the portal vein.

  19. Evaluation of periventricular hypodensity in adult hydrocephalus with CT cisternography and xenon-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Aoyagi, Masaru (Tokyo Medical and Dental Univ. (Japan). School of Medicine)

    1984-06-01

    Metrizamide CT cisternography and Xenon-enhanced CT were employed to evaluate the periventricular hypodensity (PVH). CT cisternography was performed on adult cases with suspected communicating hydrocephalus, of which 43 cases showing ventricular reflux were investigated. In those cases in which significant transition of metrizamide into the area of PVH was followed after the ventricular reflux and stasis, the shunt operation was effective. The PVH disappeared post-operatively. However, in cases with PVH in which the metrizamide penetration did not occur, the PVH did not disappear post-operatively and clinical improvement was not detected. Xenon-enhanced CT was performed in six cases. Three cases exhibited communicating hydrocephalus, in which the area of PVH was not enhanced by metrizamide with CT cisternography. The other cases demonstrated acute high pressure hydrocephalus. The PVH in the former cases was neither enhanced by Xenon nor metrizamide, while the latter was enhanced significantly. Studies suggested that the reversible PVH was the result of an abnormally increased transition of cerebrospinal fluid through the ependymal layer, while the irreversible PVH resulted from the axonal destruction or demyelination of the periventricular white matter.

  20. Semiautomatic evaluation procedures for quantitative CT of the lung.

    Science.gov (United States)

    Kalender, W A; Fichte, H; Bautz, W; Skalej, M

    1991-01-01

    Accuracy, reproducibility, and objectivity are important in quantitative assessment of lung density and structure by CT, and the measurement has to be carried out under tightly controlled conditions. We therefore employ respiratory gating at defined levels of inspiration for CT scanning. In the evaluation process, we found operator-induced errors of 2-6 HU standard deviation for the relatively simple task of global lung density estimates; in regional evaluations, they frequently exceeded 10 HU. We therefore developed semi-automated evaluation algorithms that isolate lung parenchyma by fast contour tracking and define subregions by shrinking, radial segmenting, and anteroposterior subdividing of the left and the right lung. Global and regional mean density values and histogram parameters were extracted. Based on our clinical studies, we estimate that an overall precision of better than 5% can be achieved in quantitative CT of the lung with cooperative patients.

  1. Thin-section chest CT findings of primary Sjoegren's syndrome: correlation with pulmonary function

    Energy Technology Data Exchange (ETDEWEB)

    Taouli, Bachir; Mourey, Isabelle [Department of Radiology, Universite Pierre et Marie Curie, Paris (France); Brauner, Michel W.; Lemouchi, Djamel [Department of Radiology, Universite Paris XIII, Bobigny (France); Grenier, Philippe A. [Department of Radiology, Universite Pierre et Marie Curie, Paris (France); Institut National de la Sante et de la Recherche Medicale, Universite Pierre et Marie Curie, Paris (France)

    2002-06-01

    The purpose of this study was to describe thin-section CT findings of lung involvement in patients with primary Sjoegren's syndrome (PSS), and to correlate them with pulmonary function tests (PFT). The chest thin-section CT examinations of 35 patients with proven diagnosis of PSS and respiratory symptoms were retrospectively assessed by two observers, in a first step independently with interobserver evaluation, and in a second step in consensus. The extent of the most frequent CT findings was scored. Correlation was made with PFT in 31 of these patients. Three main CT patterns were identified with good interobserver agreement (kappa coefficient 0.71): 19 of 35 (54%) large and/or small airways disease; 7 of 35 (20%) interstitial lung fibrosis (ILF); and 5 of 35 (14%) suggestive of lymphocytic interstitial pneumonia (LIP). The CT scans were normal in 2 patients (6%) and showed only dilatation of pulmonary vessels due to pulmonary arterial hypertension in two others (6%). Airway disease patients had predominantly obstructive profiles (mean FEV{sub 1}/FVC ratio 69.7{+-}12.7%, mean MEF{sub 25} 50.1{+-}22.9%), whereas patients with ILF and LIP had predominantly restrictive profiles and/or a decreased diffusing lung capacity (mean TLC 87.0{+-}26.0 and 64.6{+-}18.6%, mean DL{sub CO} 57.4{+-}21.2 and 52.0{+-}8.0%). Significant correlation (p<0.01) was found between the scores of ground-glass attenuation and TLC (r=-0.84) and DL{sub CO} (r=-0.70) and between the score of air trapping and FEV1 (r=-1.0). In patients with PSS and respiratory symptoms, thin-section CT may provide characterization of lung involvement which correlates with pulmonary function. (orig.)

  2. Pancreatic adenocarcinoma: dual-phase helical CT with surgical and histopathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Park, Seong Hoon; Yun, Ki Jung; Won, Jong Jin [Wonkwang University School of Medicine, Iksan (Korea, Republic of)

    2003-03-01

    To determine the accuracy of dual-phase helical CT in assessing the resectability of pancreatic ductal adenocarcinoma, and to correlate the CT findings with the surgical and histopathologic findings. Thirty patients with pathologically proven cancer of the pancreas underwent arterial-and portal-phase helical CT scanning, and in the two of these, single-level dynamic CT was performed during celiac and superior mesenteric arteriography. In 17 patients who underwent surgery for potentially resectable cancer of the pancreatic head, tumor resectability was assessed. The CT findings were analyzed and correlated with these of surgery and histopathology. In 13 (76%) of the 17 patients who underwent surgery, tumors were resectable. Their average size was 2.76 cm (arterial phase), 2.30 cm (portal phase), and 2.48 cm (pathologically determined) and the overall accuracy of helical CT for assessing resectability was 87%. In all patients, the central portion of the tumors exhibited hypoattenuation at both phases; the peripheral portion showed hypoattenuation at the arterial phase and iso- (n=10) or hyperattenuation (n=3) at the portal phase. Single-level dynamic CT depicted a persistently hypoattenuating central portion and progressive and prolonged enhancement of the periphery. CT-histopathologic correlation showed that central hypoattenuation indicated the presence of tumor cells, necrosis (n=3) and mucin (n=4), while the peripheral iso- or hyperattenuated areas seen at the portal phase represented fibrosis and inflammatory infiltration. Histopathologic examination revealed tumoral infiltration of peripancreatic fat tissue (n=11) and microvascular invasion of major peripancreatic vessels (n=7). The dual-phase helical CT is useful in the determination of resectability in pancreas cancer and CT findings represent well the histopathologic features of pancreas cancer.

  3. Pulmonary artery and right ventricle assessment in pulmonary hypertension. Correlation between functional parameters of ECG-gated CT and right-side heart catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Abel, Elodie; Jankowski, Adrien [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Pison, Christophe [Clinique univ. de pneumologie, CHU Grenoble (France); Bosson, Jean Luc [Dept. of Statistics, CIC, CHU Grenoble (France); Bouvaist, Helene [Clinique univ. de cardiologie, CHU Grenoble (France); Ferretti, Gilbert R. [Clinique univ. de radiologie et imagerie medicale, CHU Grenoble (France); Univ. J. Fourier, Grenoble (France); INSERM U 823, Inst. A. Bonniot, la Tronche (France)], e-mail: gferretti@chu-grenoble.fr

    2012-09-15

    Background: Right ventricular function predicts outcome in patients with pulmonary hypertension (PH). Therefore accurate assessment of right ventricular function is essential to graduate severity, assess follow-up, and response to therapy. Purpose: To evaluate whether PH severity could be assessed using electrocardiography-gated CT (ECG-gated CT) functional parameters. A further objective was to evaluate cardiac output (CO) using two ECG-gated CT methods: the reference Simpson technique and the fully automatic technique generated by commercially available cardiac software. Material and Methods: Our institutional review board approved this study; patient consent was not required. Twenty-seven patients who had undergone ECG-gated CT and right heart catheterization (RHC) were included. Two independent observers measured pulmonary artery (PA) diameter, PA distensibility, aorta diameter, right ventricular cardiac output (CT-RVCO) and right ventricular ejection fraction (CT-RVEF) with automatic and Simpson techniques on ECG-gated CT. RHC-CO and mean pulmonary arterial pressure (mPAP) were measured on RHC. Relationship between ECG-gated CT and RHC measurements was tested with linear regression analysis. Results: Inter-observer agreement was good for all measurements (r > 0.7) except for CT-RVCO calculated with Simpson's technique (r = 0.63). Pulmonary artery (PA) distensibility was significantly correlated to mPAP (r = -0.426, P = 0.027). CT-RVEF was correlated with mPAP only when issued from Simpson technique (r = -0.417, P = 0.034). CT-RVEF was not significantly correlated to RHC-CO (P > 0.2). CT-RVCO measured with Simpson technique (r = 0.487, P = 0.010) and automatic segmentation (r = 0.549, P 0.005) correlated equally with RHC-CO. Conclusion: CT-RVEF and CT-RVCO measured on ECG-gated CT are significantly correlated, respectively, to mPAP and RHC-CO in this population with severe reduction of the right ventricular ejection fraction and could be useful for

  4. Cerebral scedosporiosis: an emerging fungal infection in severe neutropenic patients. CT features and CT pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Marco de Lucas, Enrique; Sadaba, Pablo; Lastra Garcia-Baron, Pedro; Ruiz Delgado, Maria Luisa; Gonzalez Mandly, Andres; Gutierrez, Agustin; Diez, Consuelo [Hospital Universitario Marques de Valdecilla, Department of Radiology, Santander, Cantabria (Spain); Cuevas, Jorge; Fernandez, Fidel [Hospital Universitario Marques de Valdecilla, Department of Pathology, Santander, Cantabria (Spain); Salesa, Ricardo [Hospital Universitario Marques de Valdecilla, Department of Microbiology, Santander, Cantabria (Spain); Bermudez, Arancha [Hospital Universitario Marques de Valdecilla, Department of Hematology, Santander, Cantabria (Spain); Marco de Lucas, Fernando [Hospital de Basurto, Department of Hematology, Bilbao, Vizcaya (Spain)

    2006-02-01

    Scedosporium prolificans is an emerging opportunistic fungal agent encountered in severely neutropenic patients. The purpose of this paper is to describe the main cranial CT findings from a retrospective review of six patients (four men and two women, 18-66 years old) afflicted with disseminated infection by S. prolificans with neurological symptoms. They were severely neutropenic and presented with severe respiratory failure and conscience deterioration, with a subsequent 100% mortality. The final diagnosis was established by autopsy (performed in five patients) and blood culture findings. Cranial CT showed multiple low-density lesions in four patients without contrast enhancement located in the basal ganglia and corticomedullary junction. Autopsy findings of these lesions demonstrated necrosis and hyphae proliferation inside brain infarcts. Also, two of the patients had a subarachnoid hemorrhage, but angiography could not be performed. CT and autopsy findings were fairly similar to those encountered in cerebral aspergillosis; however, possibly because of its rapid and fatal evolution, no edema or ring enhancing lesions were encountered. Thus, Scedosporium can be included as a rare but possible cause of invasive fungal disseminated central nervous system infections in severely neutropenic patients. (orig.)

  5. Simple evaluation of CT findings in the paranasal sinuses for chronic sinusitis

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Makoto [Saiseikai Shiga Hospital, Ritto (Japan); Dejima, Kenji; Hama, Takemitsu; Ishizaka, Shigeyasu; Yasuda, Shigenobu; Fukushima, Kazuto; Murakami, Yasushi; Hisa, Yasuo

    2000-02-01

    The CT scores and scoring for improvement based on them, which we proposed previously, is a simple and highly reproducible method of evaluation of sinus units before and after an operation for chronic sinusitis. We compared this evaluation method with the results of quantitative assay and showed its advantages and disadvantages. The subjects were 258 sinuses in patients who underwent endonasal sinus surgery (ESS) in the department of otolaryngology, Kyoto Prefectural University of Medicine Hospital from April 1996 to April 1997. The subjects were evaluated according to the following 4 grades negligible shadow in the paranasal sinus CT scored 0, less than 50% shadow scored 1, more than 50% of shadow scored 2, and mostly filled with shadow scored 3. Furthermore, the preoperative and postoperative CT scores were compared and the rate of improvement was rated in the following 3 grades: score 0 for unchanged or aggravated subjects, score 1 for subjects showing improved CT score by 1 grade, and score 2 for those showing improved CT score by 2 grades or a postoperative CT score of 0. Quantitative image analysis was input into a personal computer and the ratio occupied by the shadow was calculated, as the shadow ratio. While some discrepancies were seen in parts in the comparison of the quantitative image analysis and CT scores as the former captures minute shadows, a positive correlation was obtained overall. Attention is needed to accurately evaluate small paranasal sinuses such as the frontal sinus, and small amounts of shadow, which are areas where errors may occur. A satisfactory correlation was obtained between the score for the improvement rate and the difference in the shadow ratios before and after surgery. The CT scores and the scores for the improvement rate showed no difference from the results of other evaluation methods reported in the past, and evaluation of similar precision was possible. It was thought that this simple evaluation method of CT findings in

  6. Retroperitoneal ganglioneuroma in children: CT and MRI features with histologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Cai Jinhua, E-mail: cjh710506@tom.co [Department of Radiology, Children' s Hospital, Chongqing Medical University, Chongqing 400014 (China); Zeng Yan [Department of Radiology, Second Affiliated Hospital, Chongqing Medical University, Chongqing 400010 (China); Zheng Helin; Qin Yong [Department of Radiology, Children' s Hospital, Chongqing Medical University, Chongqing 400014 (China); Kaiyong, T. [Department of Pathology, Children' s Hospital, Chongqing Medical University, Chongqing 400014 (China); Zhao Jiannong [Department of Radiology, Second Affiliated Hospital, Chongqing Medical University, Chongqing 400010 (China)

    2010-09-15

    Objective: To demonstrate the CT and MRI features with histologic correlation of retroperitoneal ganglioneuromas in children. Methods: The diagnostic images (seventeen CT scans and five MR scans) in 17 children with retroperitoneal ganglioneuroma confirmed by operation and histopathology were retrospectively reviewed, and correlated to the histologic findings. Results: All tumors presented as an oval-shaped, well-defined mass on both CT and MR images. On unenhanced CT images, calcification was detected in six masses (35.3%), and predominantly low attenuation with the CT value ranged from 22 to 38 HU (mean 29.5 HU) in all the tumors. The tumors with CT value less than 30 HU had a relatively larger amount of myxoid stroma on histopathologic sections than those with CT value more than 30 HU. Tumors showed homogeneous low signal intensity on T1-weighted images and inhomogeneous high signal intensity with interlaced or nodular low signal intensity on T2-weighted images. The post-contrast enhancement on both CT and MR images was lacking or slight in early phase, but moderate or marked in late phase. The inhomogeneous high signal intensity on T2WI, as well as the delayed enhancement corresponded to a large amount of myxoid stroma and a relatively small number of cellular components in tumors. Conclusion: An oval shape, well-defined margin, low attenuation on CT, inhomogeneous hyperintensity on T2WI, and delayed moderate or marked enhancement are typical features of retroperitoneal ganglioneuroma in children. The imaging features correlated well to the histologic findings.

  7. CT versus FDG-PET/CT response evaluation in patients with metastatic colorectal cancer treated with irinotecan and cetuximab

    DEFF Research Database (Denmark)

    Skougaard, Kristin; Johannesen, Helle Hjorth; Nielsen, Dorte

    2014-01-01

    metabolic response (PMR) rate was 56%, stable metabolic disease rate 33%, and progressive metabolic disease (PMD) rate 11%. Response agreement was poor, κ-coefficient 0.19. Hazard ratio for overall survival for responders (PR/PMR) versus nonresponders (PD/PMD) was higher for CT- than for FDG......-PET/CT evaluation. Within patients with KRAS mutations, none had PR but 44% had PMR. In conclusion, morphologic and metabolic response agreement was poor primarily because a large part of the patients shifted from SD with CT evaluation to PMR when evaluated with FDG-PET/CT. Furthermore, a larger fraction...

  8. High-resolution CT in the evaluation of occupational and environmental disease

    Energy Technology Data Exchange (ETDEWEB)

    Akira, M. [National Kinki Central Hospital for Chest Diseases, Osaka (Japan). Dept. of Radiology

    2002-01-01

    CT has an increasing role in the radiologic evaluation of occupational/environmental lung disease. The high-resolution CT (HRCT) findings of silicosis, mixed dust pneumoconiosis, coal worker's pneumoconiosis, graphite pneumoconiosis, asbestosis, talcosis, welder's lung, berylliosis, aluminum lung, and hard metal pneumoconiosis are described. Hypersensitivity pneumonitis and lung damage caused by exposure to toxic fumes also are described. HRCT pathologic correlation with each type of pneumoconiosis is focused on. HRCT is useful in achieving an accurate categorization of the parenchymal changes in each type of pneumoconiosis.

  9. Complications of hemorrhagic and ischemic stroke : a CT perfusion evaluation

    NARCIS (Netherlands)

    Dankbaar, J.W.

    2010-01-01

    In this thesis the use of CT-perfusion (CTP) imaging in the evaluation of the most severe complications of subarachnoid hemorrhage (SAH)) and ischemic stroke was explored. These complications are delayed cerebral ischemia (DCI) after SAH and damage to the blood-brain barrier (BBB) after ischemic str

  10. CT enterography: a preliminary experience in the evaluation of small bowel diseases

    Energy Technology Data Exchange (ETDEWEB)

    Costa-Silva, Luciana [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Medical School. Dept. of Supplementary Propedeutics; Martins, Tatiana [Ecoar Medicina Diagnostica, Belo Horizonte, MG (Brazil); Passos, Maria do Carmo Friche [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Medical School. Dept. of Medical Practice

    2010-09-15

    Objective: the present study was aimed at demonstrating the value of computed tomography enterography (CT enterography) and how this imaging method can be useful in the diagnostic elucidation and assessment of patients with small bowel diseases. Materials and methods: retrospective evaluation of 35 patients submitted to CT enterography in a 16-row multidetector CT equipment from May/2008 to March/2009. All the patients received intravenous and neutral oral iodinated contrast agents (polyethylene glycol). Main indications were: Crohn's disease, diarrhea of undetermined origin and suspicion of neoplasia. Results: a good correlation was observed between CT enterography findings and clinical, laboratory and endoscopic data related to the disease activity in patients with Crohn's disease. In 15 cases alterations compatible with Crohn's disease were identified, nine of them suggesting disease activity. A diagnosis was achieved in the majority of the patients with diarrhea. Carcinoid tumors were identified in two patients. Conclusion: CT enterography is a simple and effective method in the evaluation of inflammatory/neoplastic small bowel diseases, particularly in cases of Crohn's disease, indicating disease activity. One of the main advantages of this method is the possibility of evaluating associated mesenteric and extraintestinal alterations (author)

  11. Quantitative image quality evaluation for cardiac CT reconstructions

    Science.gov (United States)

    Tseng, Hsin-Wu; Fan, Jiahua; Kupinski, Matthew A.; Balhorn, William; Okerlund, Darin R.

    2016-03-01

    Maintaining image quality in the presence of motion is always desirable and challenging in clinical Cardiac CT imaging. Different image-reconstruction algorithms are available on current commercial CT systems that attempt to achieve this goal. It is widely accepted that image-quality assessment should be task-based and involve specific tasks, observers, and associated figures of merits. In this work, we developed an observer model that performed the task of estimating the percentage of plaque in a vessel from CT images. We compared task performance of Cardiac CT image data reconstructed using a conventional FBP reconstruction algorithm and the SnapShot Freeze (SSF) algorithm, each at default and optimal reconstruction cardiac phases. The purpose of this work is to design an approach for quantitative image-quality evaluation of temporal resolution for Cardiac CT systems. To simulate heart motion, a moving coronary type phantom synchronized with an ECG signal was used. Three different percentage plaques embedded in a 3 mm vessel phantom were imaged multiple times under motion free, 60 bpm, and 80 bpm heart rates. Static (motion free) images of this phantom were taken as reference images for image template generation. Independent ROIs from the 60 bpm and 80 bpm images were generated by vessel tracking. The observer performed estimation tasks using these ROIs. Ensemble mean square error (EMSE) was used as the figure of merit. Results suggest that the quality of SSF images is superior to the quality of FBP images in higher heart-rate scans.

  12. Evaluation of the Pericardium with CT and MR

    OpenAIRE

    Czum, Julianna M.; Anne M. Silas; Althoen, Morgan C.

    2014-01-01

    The pericardium plays an important role in optimizing cardiac motion and chamber pressures and serves as a barrier to pathology. In addition to pericardial anatomy and function, this review article covers a variety of pericardial conditions, with mention of potential pitfalls encountered during interpretation of diagnostic imaging. Normal and abnormal appearance of pericardium on CT and MR imaging is emphasized, including dynamic imaging correlates of pericardial pathophysiology.

  13. Spiral CT of acute pulmonary thromboembolism: evaluation of pleuroparenchymal abnormalities.

    Science.gov (United States)

    Johnson, P T; Wechsler, R J; Salazar, A M; Fisher, A M; Nazarian, L N; Steiner, R M

    1999-01-01

    The goal of this work was to identify and categorize the spectrum of pulmonary parenchymal and pleural abnormalities identified by CT in patients with acute pulmonary thromboembolism (PE). A review of interpretations from 4,715 consecutive contrast-enhanced thoracic CT studies identified 41 examinations in which the diagnosis of PE was reported. Thirty-four studies were available for review, and two radiologists confirmed intraluminal defects in 31 patients. The number of emboli were counted and localized using bronchopulmonary nomenclature. Associated parenchymal and pleural abnormalities were tabulated. Of the 31 patients, 13 underwent confirmatory or correlative studies including angiography, radionuclide study, or autopsy. In addition, deep venous thrombosis was confirmed by ultrasound or MRI in 13 patients. An average of 7.5 emboli per patient was detected. Pleuroparenchymal findings were as follows: Nine patients (29%) had no acute pulmonary parenchymal or pleural abnormality. In the remaining 22 patients, pleural effusion was the most common abnormality, found in 14 of 31 (45%). Ten patients (32%) had peripheral wedge-shaped parenchymal opacities suggestive of pulmonary infarction. Normally enhancing lobar atelectasis was seen in nine patients (29%). Six patients (19%) demonstrated heterogeneous parenchymal enhancement within nonaerated lung, two of whom had pathologically proven pulmonary infarct. Thirteen of 31 patients underwent high resolution CT; a typical mosaic perfusion pattern was seen in only 1 patient. Twenty-nine percent of patients with acute PE had no acute lung parenchymal abnormality on CT; thus, the absence of parenchymal abnormality on CT does not exclude PE. High resolution CT mosaic perfusion was not a common feature of acute pulmonary embolism. Regions of decreased enhancement within nonaerated lung, seen in 19%, may prove to be an indicator of pulmonary infarction; however, this is a nonspecific finding.

  14. CT diagnosis in the evaluation of vertebral trauma

    Energy Technology Data Exchange (ETDEWEB)

    Emori, Takumi; Kadoya, Satoru; Nakamura, Tsutomu; Ito, Shotaro; Kwak, Ryungchan

    1984-12-01

    The diagnostic capability of the CT scan of the vertebral trauma and a comparison with the results of a routine roentgenogram and tomogram were studied in 11 patients. In total, there were 15 fractured vertebrae: 3 in the upper cervical, 3 in the lower cervical, and 9 in the thoracic and thoraco-lumbar vertebrae. In the detailed evaluation of the vertebral fractures, CT provided more information than plain films in all 15 fractured vertebrae, with a better visualization of the spinal bony details, particularly at the upper cervical, thoracic, and thoraco-lumbar levels, where the interpretation of the spinal abnormalities is usually difficult because of adjacent structures such as the skull and thorax. Only CT was able to demonstrate impingements on the vertebral canal by bony fragments. Post-traumatic syringomyelia was incidentally demonstrated in one patient on a plain CT. In 6 patients, conventional tomography was done, but no additional information with regard to spinal instability and spinal-cord compression was obtained. The usage of sagittal tomography was also limited, because it required a change in the patient's position, which might worsen the neurological deficits. On the other hand, a plain roentgenogram and conventional tomography were superior in the evaluation of spinal malalignment and fractures running horizontally. In summary, both plain roentgenograms and CT images provided detailed information about vertebral injury, whereas conventional tomography is judged to be inferior and not always necessary. Based on these results, our new diagnostic and therapeutic approaches using CT for the vertebral injuries were presented.

  15. Traumatic facial nerve palsy: CT patterns of facial nerve canal fracture and correlation with clinical severity

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Cheol; Kim, Sang Joon; Park, Hyun Min; Lee, Young Suk; Lee, Jee Young [College of Medicine, Dankook Univ., Chonan (Korea, Republic of)

    2002-07-01

    To analyse the patterns of facial nerve canal injury seen at temporal bone computed tomography (CT) in patients with traumatic facial nerve palsy and to correlate these with clinical manifestations and outcome. Thirty cases of temporal bone CT in 29 patients with traumatic facial nerve palsy were analyzed with regard to the patterns of facial nerve canal involvement. The patterns were correlated with clinical grade, the electroneurographic (ENoG) findings, and clinical outcome. For clinical grading, the House-Brackmann scale was used, as follows:grade I-IV, partial palsy group; grade V-VI, complete palsy group. The electroneuronographic findings were categorized as mild to moderate (below 90%) or severe (90% and over) degeneration. In 25 cases, the bony wall of the facial nerve canals was involved directly (direct finding): discontinuity of the bony wall was onted in 22 cases, bony spicules in ten, and bony wall displacement in five. Indirect findings were canal widening in nine cases and adjacent bone fracture in two. In one case, there were no direct or indirect findings. All cases in which there was complete palsy (n=8) showed one or more direct findings including spicules in six, while in the incomplete palsy group (n=22), 17 cases showed direct findings. In the severe degeneration group (n=13), on ENog, 12 cases demonstrated direct findings, including spicules in nine cases. In 24 patients, symptoms of facial palsy showed improvement at follow up evaluation. Four of the five patients in whom symptoms did not improve had spicules. Among ten patients with spicules, five underwent surgery and symptoms improved in four of these; among the five patients not operated on , symptoms did not improve in three. In most patients with facial palsy after temporal bone injury, temporal bone CT revealed direct or indirect facial nerve canal involvement, and in complete palsy or severe degeneration groups, there were direct findings in most cases. We believe that meticulous

  16. Multidetector CT Assessment of Lymph Node Size for Nodal Staging in Patients with Potentially Operable Squamous Esophageal Cancer and the 18F-FDG Positron Emission Tomography CT Correlation

    Energy Technology Data Exchange (ETDEWEB)

    Yoom, Soo Kyung; Jung, Jung Im; Ahn, Myeong Im; Park, Jae Gil; Yoo, Ie Ryung; Park, Seog Hee [Catholic University Seoul St. Mary' s Hospital, Seoul (Korea, Republic of); Park, Mi Jung [Gyeongsang National University Hospital, Junju (Korea, Republic of); Park, Hyun Jin [Catholic University St. Vincent Hospital, Suwon (Korea, Republic of)

    2010-03-15

    To investigate the size criteria of multidetector computed tomography (MDCT) for the evaluation metastatic lymph nodes (LNs) for potentially operable squamous esophageal cancer, and to compare this information with the results of positron emission tomography-CT (PET-CT). Twenty-four patients who underwent radical esophagectomy for esophageal cancer were studied. All patients had preoperative MDCT and PET-CT. The MDCT findings were compared with those of PET-CT and were correlated with the surgical records. The receiver operating characteristic (ROC) curve method was used to determine the appropriate cut-off value to distinguish benign from metastatic LNs. The size of metastatic LNs (9.35 {+-} 3.41 mm) was significantly larger than that of benign LNs (5.74 {+-} 1.64 mm) (p<0.001). The best cut-off value was 7 mm (81.8% sensitivity, 80.8% specificity). PET-CT detected all metastatic LNs except for four in the peritumoral region. The sensitivity and specificity of metastatic LN evaluation on PET-CT were 82.6% and 99.4%, respectively. Only one LN without metastasis showed increased fluoro-2-deoxy-D-glucose uptake on PET-CT. Size of metastatic LNs can typically be < 10 mm. For MDCT, the short diameter of 7 mm may be the optimal criterion. PET-CT is very accurate for the assessment of metastatic LNs except for those in the peritumoral region.

  17. Evaluation of registration methods on thoracic CT

    DEFF Research Database (Denmark)

    Murphy, K.; van Ginneken, B.; Reinhardt, J.

    2011-01-01

    . This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which...... method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing...

  18. Correlation between [{sup 18}F]FDG PET/CT and volume perfusion CT in primary tumours and mediastinal lymph nodes of non-small-cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sauter, Alexander W.; Spira, Daniel; Schulze, Maximilian; Pfannenberg, Christina; Claussen, Claus D.; Horger, Marius S. [Eberhard Karls University, Diagnostic and Interventional Radiology, Department of Radiology, Tuebingen (Germany); Hetzel, Juergen [Eberhard Karls University, Department of Oncology, Hematology, Immunology, Rheumatology and Pulmonology, Tuebingen (Germany); Reimold, Matthias [Eberhard Karls University, Nuclear Medicine, Department of Radiology, Tuebingen (Germany); Klotz, Ernst [Siemens Healthcare, Computed Tomography, Forchheim (Germany)

    2013-05-15

    The aim of this study was to investigate correlations between glucose metabolism as determined by [{sup 18}F]FDG PET/CT and tumour perfusion as quantified by volume perfusion CT in primary tumours and mediastinal lymph nodes (MLN) of patients with non-small-cell lung cancer (NSCLC). Enrolled in the study were 17 patients with NSCLC. [{sup 18}F]FDG uptake was quantified in terms of SUV{sub max} and SUV{sub avg}. Blood flow (BF), blood volume (BV) and flow extraction product (K{sup trans}) were determined as perfusion parameters. The correlations between the perfusion parameters and [{sup 18}F]FDG uptake values were subsequently evaluated. For the primary tumours, no correlations were found between perfusion parameters and [{sup 18}F]FDG uptake. In MLN, there were negative correlations between BF and SUV{sub avg} (r = -0.383), BV and SUV{sub avg} (r = -0.406), and BV and SUV{sub max} (r = -0.377), but not between BF and SUV{sub max}, K{sup trans} and SUV{sub avg}, or K{sup trans} and SUV{sub max}. Additionally, in MLN with SUV{sub max} >2.5 there were negative correlations between BF and SUV{sub avg} (r = -0.510), BV and SUV{sub avg} (r = -0.390), BF and SUV{sub max} (r = -0.536), as well as BV and SUV{sub max} (r = -0.346). Perfusion and glucose metabolism seemed to be uncoupled in large primary tumours, but an inverse correlation was observed in MLN. This information may help improve therapy planning and response evaluation. (orig.)

  19. Correlation between the Degree and Severity of Symptoms and CT scan Changes in Chronic Rhinosinusitis (CRS

    Directory of Open Access Journals (Sweden)

    H. Moghaddasi

    2008-01-01

    Full Text Available Background/Objective: find out whether any correlation exists between the degree and severity of symptoms as assessed by the SNOT-20 questionnaire and CT scan changes as graded by Lund-Mackay scoring system in chronic rhinosinusitis (CRS."nPatients and Methods: Fifties patients attending the otolaryngology department and diagnosed with CRS were prospectively entered in this study. All patients had their CT scans graded by using the Lund-Mackay  with the sino-nasal outcome questionnaire (SNOT-20. Correlation analysis was conducted to determine whether the CT scan stage as assigned by Lund Mackay staging system correlated with the SNOT-20 scores."nResults: The mean age of our patients was 32.4±8.5 and 32(64% of them were male and 18(36% were female. The mean SNOT-20 was 45±8.7 (29-67 and the mean Lund-Mackay sinus score was 18.5±5 (8- 24.The mean SNOT-20 score was higher for postnasal drip (PND and facial pain, and the lowest mean scores were for dizziness and ear pain. The Pearson's correlation coefficient confirmed that there was a good correlation between SNOT-20 scores and CT scores (Pearson correlation coefficient 0.77; P value, 0.0001."nConclusion: Patients with higher symptom scores are more likely to have CT imaging evidence of rhinosinusitis. In patients with isolated sleep or systematic symptoms, the likelihood of rhinosinusitis is less, even if symptoms are severe. Therefore, in these patients, sinus CT-scan should be considered before treatment to establish the diagnosis of chronic rhinosinusitis due to that a number of these patients may be doing not have rhinosinusitis.

  20. Using Abdominal CT Data for Visceral Fat Evaluation

    Directory of Open Access Journals (Sweden)

    M Pop

    2013-10-01

    Full Text Available Background: Quantitative assessment of body fat is important for the diagnosis and treatment of diseases related to obesity, Computed tomography (CT becoming the standard procedure for measuring the abdominal fat distribution. Material and method: The retrospective study included 111 inpatients, who underwent routine abdominal CT exams in the Radiology Laboratory of SCJU Tg.Mures (2013. MPR MDCT (SOMATOM AS 64 data was processed using a custom written MATLAB R2009b software, ImageJ being used for tracing of the visceral fat area (VFA. Patient data (including blood glucose, cholesterol and triglycerides were analyzed using MO Excel and GraphPad Inprism5. Results: Visceral Fat percentage varied in population from 14.59-68.69 (SD = 11.83 with significant difference between sexes (male vs. female, 46.98 vs. 31.62, p 220 mg% and triglycerides >150 mg% are significantly associated with the VF percent (p <0.05. Overall there is a weak correlation between the lab variables and the measured fat, the strongest one being between triglycerides and the VFA (r = +0.23 and between age and VFA percentage (certain samples. Conclusions: The technique used should decreases the human error in marking of the fat areas providing a better estimation of the VF/VF percentage. CT measured VF relates with certain lab tests. Further analysis, is required for a better use of CT in obesity related pathology diagnosis and treatment

  1. Correlation of intestinal disaccharidase activities with the C/T-13910 variant and age

    Institute of Scientific and Technical Information of China (English)

    Nabil Sabri Enattah; Mikko Kuokkanen; Carol Forsblom; Sirajedin Natah; Aino Oksanen; Irm(a) J(a)rvel(a); Leena Peltonen; Erkki Savilahti

    2007-01-01

    AIM: To correlate the C/T-13910 variant, associated with lactase persistence/non-persistence (adulttype hypolactasia) trait, with intestinal disaccharidase activities in different age groups of the adult population.METHODS: Intestinal biopsies were obtained from 222 adults aged 18 to 83 years undergoing upper gastrointestinal endoscopy because of unspecified abdominal complaints. The biopsies were assayed for lactase, sucrase and maltase activities and genotyped for the C/T-13910 variant using PCR-minisequencing.RESULTS: There was a significant correlation between lactase activity and the C/T-13910 variant (P < 0.00001).The mean level of lactase activity among subjects with C/C-13910 genotype was 6.86 ± 0.35 U/g, with C/T-13910 genotype 37.8 ± 1.4 U/g, and with T/T-13910 genotype 57.6 ± 2.4 U/g protein, showing a trimodal distribution of this enzyme activity. Significant differences were also observed in maltase activities among individuals with different C/T-13910 genotypes (P = 0.005). In contrast,in sucrase activity, no significant differences emerged between the C/T-13910 genotypes (P = 0.14). There were no statistical differences in lactase (P = 0.84), sucrase (P= 0.18), or maltase activity (P = 0.24) among different age groups. In the majority (> 84%) of the patients with the C/C-13910 genotype associated with lactase nonpersistence, the lactase activity was less than 10 U/gprotein.CONCLUSION: Our study demonstrates a statistically significant correlation between the c/T-13910 genotype and lactase activity and this correlation is not affected by age in adults but the cut-off value of 20 U/g protein used for the diagnosis of lactase non-persistence might be too high.

  2. Bacterial meningitis in newborn and infant: correlation between organism, CT findings and clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Hye Young; Park, Young Seo; Yoo, Shi Joon; Suh, Dae Chul; Chung, Young Kyo [College of Medicine, University of Ulsan, Seoul (Korea, Republic of)

    1993-03-15

    Acute bacterial meningitis often results in significant neurologic complications regardless of the antibiotics treatment Computed tomographic (CT) finding of tuberculous meningitis is fairly well known but not the findings of bacterial meningitis. This study was performed to determine the incidence of causative organisms and to correlate between the organisms and computed tomographic (CT) findings with clinical outcome of bacterial meningitis in newborns and infants. We analyzed the brain CT and clinical records of 15 infants who had been diagnosed as bacterial meningitis by CSF culture. We found that the most common organisms were Group B streptococcus in neonates without no neurologic complications in all but one and Hemophilus influenza in infants whose clinical outcomes were poor in all except one. CT findings related with poor prognosis in this study were cerebral edema, basal cisternal obliteration and enhancement, and cerebral infarction on initial CT and ventriculomegaly on follow-up CT. We concluded that CT diagnosed intracranial complications of bacterial meningitis well and could contributed to better treatment of bacterial meningitis.

  3. C-arm CT for histomorphometric evaluation of lumbar spine trabecular microarchitecture: a study on anorexia nervosa patients.

    Science.gov (United States)

    Phan, C M; Khalilzadeh, O; Dinkel, J; Wang, I S; Bredella, M A; Misra, M; Miller, K K; Klibanski, A; Gupta, R

    2013-07-01

    Bone histomorphometry measurements require high spatial resolution that may not be feasible using multidetector CT (MDCT). This study evaluated the trabecular microarchitecture of lumbar spine using MDCT and C-arm CT in a series of young adult patients with anorexia nervosa (AN). 11 young females with AN underwent MDCT (anisotropic resolution with a slice thickness of ~626 μm) and C-arm CT (isotropic resolution of ~200 µm). Standard histomorphometric parameters the of L1 vertebral body, namely the apparent trabecular bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN) and trabecular separation (TbSp), were analysed using MicroView software (GE Healthcare, Piscataway, NJ). Bone mineral density (BMD) was measured using dual-energy X-ray absorptiometry. Trabecular parameters derived from MDCT and C-arm CT were compared, and their association with BMD parameters was evaluated. Histomorphometric parameters derived from C-arm CT, namely TbTh, TbN and TbSp, were significantly different from the corresponding MDCT parameters. There were no significant correlations between C-arm CT-derived parameters and the corresponding MDCT-derived parameters. C-arm CT-derived parameters were significantly (pC-arm CT, was significantly associated with body mass index (r=0.636) and ideal body weight (r=0.730) (pC-arm CT more accurately captures the histomorphometric parameters of trabecular morphology than MDCT in patients with AN.

  4. Bronchial asthma: correlation of quantitative CT and the pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Park, Gun; Jin, Gong Yong; Jeon, Su Bin; Han, Young Min [Chonbuk National University Hospital, Research Institute of Clinical Medicine, Jeonju (Korea, Republic of)

    2007-02-15

    The purpose of this study was to assess the availability of quantitative computed tomography (QCT) in the evaluation asthma patients and to correlate its use with the pulmonary function test (PFT). Thirty asthmatic patients and thirty normal volunteers were prospectively evaluated by the use of HRCT and the PFT. By using 16 slice MDCT, HRCT was performed from the apex to the base of both lungs at the end inspiration and end expiration periods in all patients and images were reconstructed to a thickness of 1 mm (window level: -750 HU, window width: 1,500 HU). We analyzed each image for the whole lung using the Pulmo CT program. PFTs including FVC and FEV1 were performed one week prior and one week after the completion of a HRCT. The Difference of QCT (the mean lung density and subrange ratio) between volunteers and asthmatic patients was analyzed by using the Student's t-test. Spearman's correlation test was used to determine the association between PFT and QCT. The mean lung density (MLD) and subrange ratio were lower in asthmatic patients than in volunteers for and expiration and no difference was seen between asthmatic patients and volunteers for end inspiration. FVC and FEV1 were lower in asthmatic patients than in volunteers. A decrease in FVC and FEV1 correlated with changes in the MLD and subrange ratio for end expiration. QCT such as MLD and the subrange ratio using HRCT can be used to indirectly assess the pulmonary function of the asthma patient. The PFT seems to correlate better with the MLD and subrange ratio for expiratory QCT of the asthma patient than with inspiratory QCT.

  5. Optimizing CT for the evaluation of vestibular aqueduct enlargement:Inter-rater reproducibility and predictive value of reformatted CT measurements

    Institute of Scientific and Technical Information of China (English)

    Misun Hwang; Ryan Marovich; Samuel S. Shin; David Chi; Barton F. Branstetter IV

    2015-01-01

    Enlarged vestibular aqueduct (EVA), the most frequent identifiable cause of congenital hearing loss, is evaluated with high-definition multi-detector CT in the axial plane. Our purpose was to determine which reformatted CT measurements are most reproducible. Seven multiplanar reformatted images were created for each of the 64 temporal bones in patients with EVA. Intraclass correlation coefficients (ICC) were used to assess inter-observer variability, and both linear regression and ROC analyses were used to compare the measurements with severity of hearing loss, as assessed by pure tone audiometry. All seven measurements had excellent inter-observer variability, with average-measure ICC ranging from 0.92 to 0.98. There was no statistically significant correlation between the radiologic degree of aqueduct enlargement and severity of hearing loss using any of the seven measurements;ROC analyses revealed areas under the curves ranging from 0.57 to 0.73. Optimal accuracy was obtained with a threshold of 1.75 mm as measured at the aqueductal aperture in the P€oschl plane, with sensitivity of 0.75 and specificity of 0.63. Although the radiologic measurement may not serve as a reliable tool for assessing severity of EVA, P€oschl plane reformatting has proven to be better than conventional axial acquisition plane for identifying patients with clinically significant hearing loss.

  6. Staging of colorectal carcinoma by spiral CT with water enema : correlation with pathologic staging using new AJCC classification

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyoung Jung; Lee, Dong Ho; Ko, Young Tae [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1999-05-01

    In cases of colorectal cancer, to correlate the spiral CT staging with water enema with the pathologic staging according to the new AJCC classification. Ninety four patients with pathologically proven carcinoma of the colon who had undergone spiral CT with water enema were evaluated. CT scans were obtained after enema involving about 600-1,200mL of water. Scanning was performed from the diaphragmatic dome to the symphysis pubis using 10mm collimation thickness, 12mm table feed, and 10mm reconstruction interval. The TNM stage, as seen on spiral CT, was determined without reference to the pathologic results. Staging was performed according to the new AJCC cancer staging manual(1997). The pathologic T-stage was T1 in four cases(4.3%), T2 in 11(11.7%), T3 in 72(76.6%), and T4 in seven(7.4%). The pathologic N-stage was N0 in 57 cases(60.6%), N1 in 25 cases(26.6%), and N2 in 12(12.8%). The pathologic M-stage was M0 in 90 cases(95.7%) and M1 in four(4.3%). The detection rate of colon cancer using spiral CT with water enema was 97.9%. At the T-stage, pathologic correlation was good in 68.1% of cases(64/94). Nine patients(9.6%) were overstaged and 21(22.3%) were understaged. At the N-stage, pathologic correlation was good in 54.3% of cases(51/94), with 27 patients(28.7%) overstaged and sixteen(17.0%) understaged. At the M-stage, pathologic correlation was good in 95.7% of cases(90/94). Four patients(4.3%) were overstaged. The accuracy of staging of colorectal carcinoma by spiral hydro-CT was 68.1% at the T-stage, 54.3% at the N-stage, and 95.7% at the M-stage. As seen on spiral CT with water enema, the T-stage tended to wards understaging and the N-stage towards overstaging.

  7. Dual-energy micro-CT imaging of pulmonary airway obstruction: correlation with micro-SPECT

    Science.gov (United States)

    Badea, C. T.; Befera, N.; Clark, D.; Qi, Y.; Johnson, G. A.

    2014-03-01

    To match recent clinical dual energy (DE) CT studies focusing on the lung, similar developments for DE micro-CT of the rodent lung are required. Our group has been actively engaged in designing pulmonary gating techniques for micro- CT, and has also introduced the first DE micro-CT imaging method of the rodent lung. The aim of this study was to assess the feasibility of DE micro-CT imaging for the evaluation of airway obstruction in mice, and to compare the method with micro single photon emission computed tomography (micro-SPECT) using technetium-99m labeled macroaggregated albumin (99mTc-MAA). The results suggest that the induced pulmonary airway obstruction causes either atelectasis, or air-trapping similar to asthma or chronic bronchitis. Atelectasis could only be detected at early time points in DE micro-CT images, and is associated with a large increase in blood fraction and decrease in air fraction. Air trapping had an opposite effect with larger air fraction and decreased blood fraction shown by DE micro-CT. The decrease in perfusion to the hypoventilated lung (hypoxic vasoconstriction) is also seen in micro-SPECT. The proposed DE micro-CT technique for imaging localized airway obstruction performed well in our evaluation, and provides a higher resolution compared to micro-SPECT. Both DE micro-CT and micro-SPECT provide critical, quantitative lung biomarkers for image-based anatomical and functional information in the small animal. The methods are readily linked to clinical methods allowing direct comparison of preclinical and clinical results.

  8. Anatomical evaluation of CT-MRI combined femoral model

    Directory of Open Access Journals (Sweden)

    Kim Gyu-Ha

    2008-01-01

    Full Text Available Abstract Background Both CT and MRI are complementary to each other in that CT can produce a distinct contour of bones, and MRI can show the shape of both ligaments and bones. It will be ideal to build a CT-MRI combined model to take advantage of complementary information of each modality. This study evaluated the accuracy of the combined femoral model in terms of anatomical inspection. Methods Six normal porcine femora (180 ± 10 days, 3 lefts and 3 rights with ball markers were scanned by CT and MRI. The 3D/3D registration was performed by two methods, i.e. the landmark-based 3 points-to-3 points and the surface matching using the iterative closest point (ICP algorithm. The matching accuracy of the combined model was evaluated with statistical global deviation and locally measure anatomical contour-based deviation. Statistical analysis to assess any significant difference between accuracies of those two methods was performed using univariate repeated measures ANOVA with the Turkey post hoc test. Results This study revealed that the local 2D contour-based measurement of matching deviation was 0.5 ± 0.3 mm in the femoral condyle, and in the middle femoral shaft. The global 3D contour matching deviation of the landmark-based matching was 1.1 ± 0.3 mm, but local 2D contour deviation through anatomical inspection was much larger as much as 3.0 ± 1.8 mm. Conclusion Even with human-factor derived errors accumulated from segmentation of MRI images, and limited image quality, the matching accuracy of CT-&-MRI combined 3D models was 0.5 ± 0.3 mm in terms of local anatomical inspection.

  9. Nonunion of acetabular fractures: evaluation with interactive multiplanar CT

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlman, J.E.; Fishman, E.K.; Ney, D.R.; Brooker, A.F. Jr.; Magid, D.

    1989-01-01

    Nonunions involving fractures of the acetabulum are reportedly rare, with few citings and little discussion in the literature. It is possible that acetabular nonunions go undetected because imaging of the acetabulum is difficult by conventional radiography. We report two cases of fracture nonunion involving the weight-bearing surface of the acetabulum diagnosed with the aid of computed tomography (CT) and a newly developed interactive 2D/3D orthotool that uniquely processes and reformats routine CT data. The interactive 2D/3D orthotool is a sophisticated computer program that allows dynamic viewing of standard multiplanar reconstructions in the axial, coronal, and sagittal planes as well as multiple oblique projections. The 2D/3D orthotool provides on screen correlation of two-dimensional multiplanar images with three-dimensional reconstructions of the pelvis. The authors found this capability ideally suited for studying fractures with off-axis orientation such as those through the acetabular dome, greatly facilitating the diagnosis of nonunion.

  10. Performance evaluation of the CT component of the IRIS PET/CT preclinical tomograph

    Energy Technology Data Exchange (ETDEWEB)

    Panetta, Daniele [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Belcari, Nicola [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy); Tripodi, Maria [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Burchielli, Silvia [Fondazione CNR/Toscana “G. Monasterio” – FTGM, v. G. Moruzzi 1, I-56124 Pisa (Italy); Salvadori, Piero A. [CNR Institute of Clinical Physiology (IFC-CNR), v. G. Moruzzi 1, I-56124 Pisa (Italy); Del Guerra, Alberto [Department of Physics “E. Fermi”, University of Pisa, L.go B. Pontecorvo 3, I-56127 Pisa (Italy)

    2016-01-01

    In this paper, we evaluate the physical performance of the CT component of the IRIS scanner, a novel combined PET/CT scanner for preclinical imaging. The performance assessment is based on phantom measurement for the determination of image quality parameters (spatial resolution, linearity, geometric accuracy, contrast to noise ratio) and reproducibility in dynamic (4D) imaging. The CTDI{sub 100} has been measured free in air with a pencil ionization chamber, and the animal dose was calculated using Monte Carlo derived conversion factors taken from the literature. The spatial resolution at the highest quality protocol was 6.9 lp/mm at 10% of the MTF, using the smallest reconstruction voxel size of 58.8 μm. The accuracy of the reconstruction voxel size was within 0.1%. The linearity of the CT numbers as a function of the concentration of iodine was very good, with R{sup 2}>0.996 for all the tube voltages. The animal dose depended strongly on the scanning protocol, ranging from 158 mGy for the highest quality protocol (2 min, 80 kV) to about 12 mGy for the fastest protocol (7.3 s, 80 kV). In 4D dynamic modality, the maximum scanning rate reached was 3.1 frames per minute, using a short-scan protocol with 7.3 s of scan time per frame at the isotropic voxel size of 235 μm. The reproducibility of the system was high throughout the 10 frames acquired in dynamic modality, with a standard deviation of the CT values of all frames <8 HU and an average spatial reproducibility within 30% of the voxel size across all the field of view. Example images obtained during animal experiments are also shown.

  11. Severity assessment of acute pulmonary embolism: evaluation using helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Collomb, D.; Paramelle, P.J.; Calaque, O. [Department of Radiology, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Bosson, J.L. [Department of Statistics and Vascular diseases, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Vanzetto, G. [Department of Cardiology, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Barnoud, D. [Department of Medical Intensive Care, CHU Grenoble, BP 218, BP 218, 38043, Grenoble Cedex (France); Pison, C. [Department of Pulmonary Medicine, CHU Grenoble, BP 218, 38043, Grenoble Cedex (France); Coulomb, M.; Ferretti, G.

    2003-07-01

    The objective was to evaluate the helical CT (HCT) criteria that could indicate severe pulmonary embolism (PE). In a retrospective study, 81 patients (mean age 62 years) with clinical suspicion of PE explored by HCT were studied. The patients were separated into three different groups according to clinical severity and treatment decisions: group SPE included patients with severe PE based on clinical data who were treated by fibrinolysis or embolectomy (n=20); group NSPE included patients with non-severe PE who received heparin (n=30); and group WPE included patients without PE (n=31). For each patient we calculated a vascular obstruction index based on the site of obstruction and the degree of occlusion in the pulmonary artery. We noted the HCT signs, i.e., cardiac and pulmonary artery dimensions, that could indicate acute cor pulmonale. According to multivariate analysis, factors significantly correlated with the severity of PE were: the vascular obstruction index (group SPE: 54%; group NSPE: 24%; p<0.001); the maximum minor axis of the left ventricle (group SPE: 30.2 mm; group NSPE: 40.4 mm; p<0.001); the diameter of the central pulmonary artery (group SPE: 32.4 mm; group NSPE: 28.3 mm; p<0.001); the maximum minor axis of the right ventricle (group SPE: 47.5 mm; group NSPE: 42.7 mm; p=0.029); the right ventricle/left ventricle minor axis ratio (group SPE: 1.63; group NSPE: 1.09; p<0.0001). Our data suggest that hemodynamic severity of PE can be assessed on HCT scans by measuring four main criteria: the vascular obstruction index; the minimum diameter of the left ventricle; the RV:LV ratio; and the diameter of the central pulmonary artery. (orig.)

  12. High resolution CT in children with cystic fibrosis: correlation with pulmonary functions and radiographic scores

    Energy Technology Data Exchange (ETDEWEB)

    Demirkazik, Figen Basaran E-mail: demirkaz@dialup.ankara.edu.tr; Ariyuerek, O. Macit; Oezcelik, Ugur; Goecmen, Ayhan; Hassanabad, Hossein K.; Kiper, Nural

    2001-01-01

    Objective: To compare the high resolution CT (HRCT) scores of the Bhalla system with pulmonary function tests and radiographic and clinical points of the Shwachman-Kulczycki clinical scoring system. Methods: HRCT of the chest was obtained in 40 children to assess the role of HRCT in evaluating bronchopulmonary pathology in children with cystic fibrosis (CF). The HRCT severity scores of the Bhalla system were compared with chest radiographic and clinical points of the Shwachman-Kulczycki scoring system and pulmonary function tests. Only 14 of the patients older than 6 years cooperated with spirometry. Results: HRCT scores correlated well with radiographic points (r=0.80, P<0.0001) and clinical points (r=0.67, P<0.0001) of the Shwachman-Kulczycki system, FVC (r=0.71 P=0.004) and FEV{sub 1} (r=0.66, P=0.01). Although radiographic points correlated significantly with FVC (r=0.61, P=0.02) and FEV{sub 1} (r=0.56, P=0.04), HRCT provides a more precise scoring than the chest X-ray. Conclusion: The HRCT scoring system may provide a sensitive method of monitoring pulmonary disease status and may replace the radiographic scoring in the Shwachman-Kulczycki system. It may be helpful especially in follow-up of small children too young to cooperate with spirometry.

  13. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Stefan [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Medical Centre Mannheim (UMM), University of Heidelberg, First Department of Medicine, Faculty of Medicine Mannheim, Mannheim (Germany); Wang, Rui [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Beijing (China); Schoepf, U.J.; Steinberg, Daniel H.; Spearman, James V.; Bayer, Richard R. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Hamm, Christian W. [Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany); Renker, Matthias [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany)

    2015-04-01

    The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. (orig.)

  14. Rheumatoid arthritis bone erosion volumes on CT and MRI: reliability and correlations with erosion scores on CT, MRI and radiography

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Ejbjerg, Bo J; Hasselquist, Maria;

    2007-01-01

    controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). RESULTS: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean...

  15. Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT.

    Science.gov (United States)

    Ehman, Eric C; Yu, Lifeng; Manduca, Armando; Hara, Amy K; Shiung, Maria M; Jondal, Dayna; Lake, David S; Paden, Robert G; Blezek, Daniel J; Bruesewitz, Michael R; McCollough, Cynthia H; Hough, David M; Fletcher, Joel G

    2014-01-01

    Most noise reduction methods involve nonlinear processes, and objective evaluation of image quality can be challenging, since image noise cannot be fully characterized on the sole basis of the noise level at computed tomography (CT). Noise spatial correlation (or noise texture) is closely related to the detection and characterization of low-contrast objects and may be quantified by analyzing the noise power spectrum. High-contrast spatial resolution can be measured using the modulation transfer function and section sensitivity profile and is generally unaffected by noise reduction. Detectability of low-contrast lesions can be evaluated subjectively at varying dose levels using phantoms containing low-contrast objects. Clinical applications with inherent high-contrast abnormalities (eg, CT for renal calculi, CT enterography) permit larger dose reductions with denoising techniques. In low-contrast tasks such as detection of metastases in solid organs, dose reduction is substantially more limited by loss of lesion conspicuity due to loss of low-contrast spatial resolution and coarsening of noise texture. Existing noise reduction strategies for dose reduction have a substantial impact on lowering the radiation dose at CT. To preserve the diagnostic benefit of CT examination, thoughtful utilization of these strategies must be based on the inherent lesion-to-background contrast and the anatomy of interest. The authors provide an overview of existing noise reduction strategies for low-dose abdominopelvic CT, including analytic reconstruction, image and projection space denoising, and iterative reconstruction; review qualitative and quantitative tools for evaluating these strategies; and discuss the strengths and limitations of individual noise reduction methods.

  16. AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT.

    LENUS (Irish Health Repository)

    Zarb, Francis

    2010-01-01

    The purpose of this study is to investigate the relationships among cross-sectional diameters, weight and computed tomography (CT) dose descriptors (CTDI and DLP) to identify which is best used as a measure for the establishment of DRLs in CT. Data (gender, weight, cross-sectional diameters, dose descriptors) from 56 adult patients attending for either a CT examination of the abdomen or chest was obtained from two spiral CT units using automatic milliampere modulation. The AP diameter was demonstrated as the main contributing factor influencing the dose in CT (CTDI: r(2) = 0.269, p-value < or =0.001; DLP: r(2) = 0.260, p-value < or =0.001) since it has a greater correlation with radiation dose than body weight and can thus be its substitute in dose-reduction strategies and establishment of DRLs. The advantages of using the AP diameter are that it can easily be measured prior to scanning or retrospectively from previous CT images. However, further studies on the practicality of this approach are recommended.

  17. MRI of alveolar hydatid disease of the liver; Correlative study with CT and pathology

    Energy Technology Data Exchange (ETDEWEB)

    Choji, Takashi (Yamaguchi Univ., Ube (Japan). School of Medicine); Choji, Kiyoshi; Fujita, Nobuyuki (and others)

    1990-10-01

    Results of MRI were analyzed and correlated with CT and pathological findings in 6 cases of alveolar hydatid disease of the liver (AHDL), and the role of MRI in image diagnosis was investigated. With MRI, metacestodes were observed as multiple, small, low intensity areas on T{sub 1} weighted images, and multiple, small, high intensity areas on T{sub 2} weighted images. Calcifications were observed as signal void areas (n=1) or could not be depicted. Stroma and liquefied areas were observed as non-specific solid lesions and cystic lesions, respectively. MRI was found to be more effective than CT in the detection of metacestodal vesicles. On the other hand, detection of calcification was better performed by CT (4/4) than MRI (1/4). Stroma and liquefied areas were detected with equal success by CT and MRI but the signals of liquefied areas were more defined in MRI. Invasion into the large vessels or diaphragm was also detected equally well by both CT and MRI. We concluded that MRI has a complemental role with CT in image diagnosis of AHDL. (author).

  18. CT evaluation of chronic hip joint diseases: avascular necrosis vs. osteoarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myeong Jin; Suh, Jin Seok; Lee, Jong Doo; Park, Chang Yoon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1988-12-15

    Computed tomography (CT) of the hip was done on 37 patients those who have been suffered from chronic hip joint pain. There were 18 patients of avascular necrosis of hip (AVN), 67% of whom were affected bilaterally, 15 patients of degenerative arthritis (DA), 33% bilaterally; one patient of tuberculous arthritis, rheumatoid arthritis and traumatic arthritis respectively. Comparison of the staging by means of the CT and plain film showed good correlation between the two methods. The CT findings of the AVN and OA were also compared; crescent sign or fissure, loss of congruity, and loss or change of normal asterisk sign were more commonly seen in AVN. Acetabular change especially associated cystic appearance, osteophytes formation and joint narrowing were more frequent in OA. CT showed primary and secondary change of AVN and OA more clearly without confusion than plain film. We think that CT can be helpful in evaluation and understanding of each disease process and differentiation of the two lesions in difficult case000.

  19. Analysis of CT findings with audiometric correlation in patients with otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Monobe, Hiroko [Japanese Red Cross Medical Center, Tokyo (Japan); Yamasoba, Tatuya; Kaga, Kimitaka

    2001-07-01

    It has been reported that an otospongiotic lesion in otosclerosis can be shown as a density-loss area in computed tomography (CT) of the temporal bone in patients with otosclerosis. Using CT, we evaluated the presence of otospongiotic lesion in 42 ears with otosclerosis and analyzed the relationship between CT and audiometric findings. We found otospongiotic lesions in 21 ears (50%). Bone conduction thresholds were significantly increased in ears with otospongiotic lesions compared to those without. No significant difference was observed in bone conduction thresholds between ears with lesions around the cochlea and ears with lesions anterior to the vestibule. It suggests that active lesions detected on CT may be more readily cause sensorineural deafness. (author)

  20. Correlation between CT patterns and pathological classification of intraductal papillary mucinous neoplasm

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jing [Department of Imaging, Tongji Hospital of Tongji University, 389 Xincun Road, Shanghai 200065 (China)], E-mail: Zhangjingyxd@163.com; Wang Peijun [Department of Imaging, Tongji Hospital of Tongji University, 389 Xincun Road, Shanghai 200065 (China)], E-mail: Tongjipjwang@vip.sina.com; Yuan Xiaodong [Department of Radiology, Changhai Hospital of the Second Military Medical University, Shanghai 200433 (China)], E-mail: yuanxiaodongzj@163.com

    2010-01-15

    Objective: To examine CT patterns of intraductal papillary mucinous neoplasm (IPMN), analyze their correlation with pathologic classification, and discuss the value of CT in the diagnosis and differential diagnosis of IPMN. Methods: CT patterns of 39 IPMN patients, whose clinical data were complete and whose diagnosis was confirmed by surgery and pathology, were classified into three types: (1) simple main pancreatic duct (MPD) dilation type, (2) MPD dilation with pancreatic cystic lesion type, and (3) simple pancreatic cystic lesion type. Correlations between the three CT types and Takada pathologic classification (MPD type, furcation type and mixture type) were analyzed. The 39 IPMN cases were pathologically classified as the benign group and the malignant/borderline group. CT characteristics including the presence or absence of mural nodules, intrafocal partitions, focal size and the degree of MPD and common bile duct (CBD) dilation were analyzed statistically. Results: A correlation was found between the CT simple MPD dilation type and the pathological MPD type, between the MPD dilation with pancreatic cystic lesion type and the furcation and mixture types, and between the simple cystic lesion type and the furcation type (p < 0.001). The benign rate was 92% in patients without intrafocal mural nodules, and 42% in patients with intrafocal mural nodules. The difference between the two groups was statistically significant (p = 0.003). The presence or absence of intrafocal partitions was not correlated with benignancy or malignancy (p = 0.793). The maximum diameter of malignant/borderline lesions was bigger than that of benign ones (p = 0.016). There was no significant difference in MPD and CBD diameters between the benign and malignant/borderline groups. Regardless of pathological classification, the MPD diameter was larger than the CBD diameter in all cases (p = 0.02). Conclusion: The three CT types of IPMN well correlated with the pathologic classification

  1. Paired inspiratory/expiratory volumetric CT and deformable image registration for quantitative and qualitative evaluation of airflow limitation in smokers with or without copd.

    Science.gov (United States)

    Nishio, Mizuho; Matsumoto, Sumiaki; Tsubakimoto, Maho; Nishii, Tatsuya; Koyama, Hisanobu; Ohno, Yoshiharu; Sugimura, Kazuro

    2015-03-01

    To evaluate paired inspiratory/expiratory computed tomography (CT; iCT/eCT) and deformable image registration for quantitative and qualitative assessment of airflow limitation in smokers. Paired iCT/eCT images acquired from 35 smokers (30 men and 5 women) were coregistered and subtraction images (air trapping CT images [aCT]) generated. To evaluate emphysema quantitatively, the percentage of low-attenuation volume (LAV%) on iCT was calculated at -950 HU, as were mean and kurtosis on aCT for quantitative assessment of air trapping. Parametric response maps of emphysema (PRMe) and of functional small airways disease (PRMs) were also obtained. For qualitative evaluation of emphysema, low-attenuation areas on iCT were scored by consensus of two radiologists using Goddard classification. To assess air trapping qualitatively, the degree of air trapping on aCT was scored. For each quantitative and qualitative index, the Spearman rank correlation coefficient for forced expiratory flow in 1 second was calculated, and differences in correlation coefficients were statistically tested. The correlation coefficients for the indices were as follows: mean on aCT, 0.800; kurtosis on aCT, -0.726; LAV%, -0.472; PRMe, -0.570; PRMs, -0.565; addition of PRMe and PRMs, -0.653; emphysema score, -0.502; air trapping score, -0.793. The indices showing significant differences were as follows: mean on aCT and addition of PRMe and PRMs (P = 1.43 × 10(-8)); air trapping score and emphysema score (P = .0169). Air trapping images yielded more accurate quantitative and qualitative evaluation of airflow limitation than did LAV%, PRMe, PRMs, and Goddard classification. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  2. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  3. The diagnostic utility of ultrasonography, CT and PET/CT for the preoperative evaluation of cervical lymph node metastasis inpapillary thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim Young Sang; Lee, Tae Hyun; Park, Dong Hee [Dept. of Radiology, Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    2016-08-15

    To compare the diagnostic utility of ultrasonography (US), CT and positron emission tomography/CT (PET/CT) in the preoperative evaluation of cervical lymph node metastasis in patients with papillary thyroid carcinoma. The study population consisted of 300 patients with pathologically diagnosed papillary thyroid carcinoma after thyroidectomy and neck dissection. Preoperative US, CT, and PET/CT findings were compared with pathologic outcomes after thyroidectomy and neck dissection. Sensitivity in detecting central lymph node metastasis (US 29.9%, CT 27.9%, PET/CT 18.8%) was lower than that for lateral lymph node metastasis (US 56.3%, CT 66.2%, PET/CT 43.7%). Specificity in detecting central lymph node metastasis (US 80.6%, CT 77.7%, PET/CT 83.0%) was lower than that for lateral lymph node metastasis (US 96.8%, CT 80.6%, PET/CT 95.2%). The combination of US and CT had higher specificity (77.3%) and higher sensitivity (33.1%) than US alone. PET/CT has no significant additional benefit over the combination of US and CT. In preoperative evaluations of neck lymph node metastasis, US and CT and PET/CT are more useful in lateral lymph node areas than in central lymph node areas. The combination of US and CT has higher sensitivity than US alone.

  4. Correlation of CT, MR, and Histopathology in Incomplete Partition-II Cochlear Anomaly.

    Science.gov (United States)

    Leung, Katherine J; Quesnel, Alicia M; Juliano, Amy F; Curtin, Hugh D

    2016-06-01

    To correlate the computed tomography (CT) and magnetic resonance imaging (MR) findings in a patient with incomplete partition-type II (IP-II) anomaly with histopathology in a similar human temporal bone specimen. To discover the histologic correlate of a common finding on MR of an "apparent" interscalar septum (IS). A patient with sensorineural hearing loss and imaging findings characteristic of IP-II, and a patient with histopathologic IP-II anomaly. High-resolution CT, MR, and review of postmortem temporal bone histopathology. Correlation of temporal bone histopathology with CT and MR findings. Consistent findings of IP-II anomaly on CT, absence of the IS between the more distal turns and flattening of the interscalar ridge between the distal basal turn and the middle turn, were present. The signal void surrounding the cochlea on MR also demonstrated flattening of the interscalar ridge. However, a thin band-like area of low T2 signal was seen, which could be mistaken for an IS. Correlation with temporal bone histopathology revealed that the modiolus was foreshortened, and the spiral ganglion neuron dendritic processes continued toward the upper middle turn through the osseous spiral lamina, likely accounting for the MR finding. Correlation of CT, MR, and histopathology in IP-II shows an "apparent" segmentation representing a continuum of neurosensory elements in approximately the same location of the expected location of a normal IS. Care should be taken when interpreting MR imaging in isolation. Understanding the bony outline of the cochlea on imaging may prove to be complementary.

  5. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CTCT) evaluation of the temporomandibular joint (TMJ) condylar morphology

    Energy Technology Data Exchange (ETDEWEB)

    Geiger, Daniel [Sapienza University of Rome, Department of Radiological, Oncological and Pathological Sciences, Rome (Italy); Bae, Won C.; Statum, Sheronda; Du, Jiang; Chung, Christine B. [University of California-San Diego, Department of Radiology, San Diego, CA (United States)

    2014-01-15

    Temporomandibular dysfunction involves osteoarthritis of the TMJ, including degeneration and morphologic changes of the mandibular condyle. The purpose of this study was to determine the accuracy of novel 3D-UTE MRI versus micro-CTCT) for quantitative evaluation of mandibular condyle morphology. Nine TMJ condyle specimens were harvested from cadavers (2 M, 3 F; age 85 ± 10 years, mean ± SD). 3D-UTE MRI (TR = 50 ms, TE = 0.05 ms, 104-μm isotropic-voxel) was performed using a 3-T MR scanner and μCT (18-μm isotropic-voxel) was also performed. MR datasets were spatially registered with a μCT dataset. Two observers segmented bony contours of the condyles. Fibrocartilage was segmented on the MR dataset. Using a custom program, bone and fibrocartilage surface coordinates, Gaussian curvature, volume of segmented regions, and fibrocartilage thickness were determined for quantitative evaluation of joint morphology. Agreement between techniques (MRI vs. μCT) and observers (MRI vs. MRI) for Gaussian curvature, mean curvature, and segmented volume of the bone were determined using intraclass correlation coefficient (ICC) analysis. Between MRI and μCT, the average deviation of surface coordinates was 0.19 ± 0.15 mm, slightly higher than the spatial resolution of MRI. Average deviation of the Gaussian curvature and volume of segmented regions, from MRI to μCT, was 5.7 ± 6.5 % and 6.6 ± 6.2 %, respectively. ICC coefficients (MRI vs. μCT) for Gaussian curvature, mean curvature, and segmented volumes were 0.892, 0.893, and 0.972, respectively. Between observers (MRI vs. MRI), the ICC coefficients were 0.998, 0.999, and 0.997, respectively. Fibrocartilage thickness was 0.55 ± 0.11 mm, as previously described in the literature for grossly normal TMJ samples. 3D-UTE MR quantitative evaluation of TMJ condyle morphology ex-vivo, including surface, curvature, and segmented volume, shows high correlation against μCT and between observers. In addition, UTE MRI allows

  6. Simulation evaluation of quantitative myocardial perfusion assessment from cardiac CT

    Science.gov (United States)

    Bindschadler, Michael; Modgil, Dimple; Branch, Kelley R.; La Riviere, Patrick J.; Alessio, Adam M.

    2014-03-01

    Contrast enhancement on cardiac CT provides valuable information about myocardial perfusion and methods have been proposed to assess perfusion with static and dynamic acquisitions. There is a lack of knowledge and consensus on the appropriate approach to ensure 1) sufficient diagnostic accuracy for clinical decisions and 2) low radiation doses for patient safety. This work developed a thorough dynamic CT simulation and several accepted blood flow estimation techniques to evaluate the performance of perfusion assessment across a range of acquisition and estimation scenarios. Cardiac CT acquisitions were simulated for a range of flow states (Flow = 0.5, 1, 2, 3 ml/g/min, cardiac output = 3,5,8 L/min). CT acquisitions were simulated with a validated CT simulator incorporating polyenergetic data acquisition and realistic x-ray flux levels for dynamic acquisitions with a range of scenarios including 1, 2, 3 sec sampling for 30 sec with 25, 70, 140 mAs. Images were generated using conventional image reconstruction with additional image-based beam hardening correction to account for iodine content. Time attenuation curves were extracted for multiple regions around the myocardium and used to estimate flow. In total, 2,700 independent realizations of dynamic sequences were generated and multiple MBF estimation methods were applied to each of these. Evaluation of quantitative kinetic modeling yielded blood flow estimates with an root mean square error (RMSE) of ~0.6 ml/g/min averaged across multiple scenarios. Semi-quantitative modeling and qualitative static imaging resulted in significantly more error (RMSE = ~1.2 and ~1.2 ml/min/g respectively). For quantitative methods, dose reduction through reduced temporal sampling or reduced tube current had comparable impact on the MBF estimate fidelity. On average, half dose acquisitions increased the RMSE of estimates by only 18% suggesting that substantial dose reductions can be employed in the context of quantitative myocardial

  7. Evaluation of angiogenesis in colorectal carcinoma with multidetector-row CT multislice perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Feng Shiting, E-mail: fst1977@163.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Sun Canhui, E-mail: canhuisun@sina.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Li Ziping, E-mail: liziping163@tom.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Mak, Henry Ka-Fung, E-mail: makkf@hkucc.hku.h [Department of Diagnostic Radiology, University of Hong Kong, Hong Kong (China); Peng Zhenpeng, E-mail: ppzhen@21cn.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Guo Huanyi, E-mail: guohuanyi@163.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China); Meng Quanfei, E-mail: mzycoco@gmail.co [Department of Radiology, First Affiliated Hospital of SunYat-sen University, Guangzhou 510080 (China)

    2010-08-15

    To evaluate the correlation between 64 multidetector-row CT (64MDCT) perfusion imaging in colorectal carcinoma and microvessel density (MVD) and vascular endothelial growth factor (VEGF), 64MDCT perfusion imaging was performed in 33 patients with pathologically verified colorectal carcinoma. These images were analyzed with perfusion functional software, and time-density curves (TDC) were created for the region of interest (ROI) encompassing the tumor, the target artery and vein. The individual perfusion maps generated indicated blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability-surface area product (PS). MVD and VEGF were evaluated by immunohistochemical staining with anti-CD34 and anti-VEGF, respectively. Correlations between MVD or VEGF with CT perfusion parameters and clinicopathological factors (Dukes' stages, invasion depth, and lymph node and liver metastasis) were also investigated. MVD in the colorectal carcinoma was 22.61 {+-} 9.01 per x200 field. The scores obtained for VEGF expression were 4.15 {+-} 1.09. VEGF staining was positive in 25 of 29 tumors (86.2%). There was no significant correlation between the presence of MVD, VEGF expression and clinicopathological factors (P > 0.05). There was also no correlation between MVD, VEGF expression, and any dynamic CT parameters (P > 0.05). The BV and MTT were significantly higher in tumors demonstrating serous coat invasion than in those without it (t = -2.63, -2.24, P = 0.0137, 0.0331, respectively). BV was also significantly correlated with tumor size (r = 0.41, P = 0.02). Neither BF nor PS was correlated with clinicopathological factors. In conclusion, 64MDCT perfusion imaging, MVD, and VEGF may reflect angiogenic activity, but no significant correlation among these factors.

  8. The post-arthro-CT of the wrist clinical evaluation

    CERN Document Server

    Scheurecker, G

    2001-01-01

    To compare the diagnostic effectiveness of post-arthro-CT (PACT) and 3-compartment wrist arthrography (AG) both separate and combined versus wrist arthroscopy for scapho-lunate ligament (SLL), luno-triquetral ligament (LTL) and triangular fibrocartilage (TFC) defects and chondromalacia of the carpal bones. Material and methods: in 58 patients (16-69 years) the affected wrist was examined initially by conventional 3-compartment wrist arthrography with digital subtraction technique during injection followed by digital stress images. Afterwards spiral arthro-CT was performed in the semi-coronal and axial plane with 1 mm slice thickness and secondary true-coronal and sagittal reconstructions. Within 1 month arthroscopy was performed in general anesthesia utilizing standard joint entry points combined with routine digital picture archiving. All examinations were evaluated for SLL, LTL and TFC defects, PACT and AS for ChM too. Results: AG versus AS: the following detection rates were observed (AG and AS positive/AG...

  9. Measurement of tumor volumes of hepatocellular carcinoma (HCC) by computed tomography (CT). Correlation with several tumor markers

    Energy Technology Data Exchange (ETDEWEB)

    Yoneshima, Manabu; Sawabu, Norio; Toya, Daishu

    1984-09-01

    Tumor volumes of HCC were measured by CT using planimeter and the clinical value of this measurement was evaluated by comparing several tumor markers. Tumor volumes measured by CT roughly agreed with those measured by angiography. In some cases, volumes from ultrasonography were smaller than those from CT and angiography. Tumor volumes measured by CT correlated significantly with the levels of ..cap alpha..-fetoprotein (AFP) but didn't relate to the presence of hepatoma specific ..gamma..-GTP isoenzyme (novel ..gamma..-GTP) nor to the values and positivities of LAI assay. In small HCCs (<=30 cm/sup 3/), the presence of novel ..gamma..-GTP and the levels of AFP were significantly lower than for larger tumors of HCC, but LAI assay wasn't lower. The non-tumorous volumes and the ratio of the non-tumorous volume to the whole liver volume didn't relate to the tests of liver function except for the presence of ascites.

  10. Volumetric evaluation of dual-energy perfusion CT by the presence of intrapulmonary clots using a 64-slice dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Munemasa; Nakashima, Yoshiteru; Kunihiro, Yoshie; Nakao, Sei; Matsunaga, Naofumi [Dept. of Radiology, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan)], e-mail: radokada@yamaguchi-u.ac.jp; Morikage, Noriyasu [Medical Bioregulation Dept. of Organ Regulatory Surgery, Yamaguchi Univ. Graduate School of Medicine, Yamaguchi (Japan); Sano, Yuichi [Dept. of Radiology, Yamaguchi Univ. Hospital, Yamaguchi (Japan); Suga, Kazuyoshi [Dept. of Radiology, St Hills Hospital, Yamaguchi (Japan)

    2013-07-15

    Background: Dual-energy perfusion CT (DE{sub p}CT) directly represents the iodine distribution in lung parenchyma and low perfusion areas caused by intrapulmonary clots (IPCs) are visualized as low attenuation areas. Purpose: To evaluate if volumetric evaluation of DE{sub p}CT can be used as a predictor of right heart strain by the presence of IPCs. Material and Methods: One hundred and ninety-six patients suspected of having acute pulmonary embolism (PE) underwent DE{sub p}CT using a 64-slice dual-source CT. DE{sub p}CT images were three-dimensionally reconstructed with four threshold ranges: 1-120 HU (V{sub 120}), 1-15 HU (V{sub 15}), 1-10 HU (V{sub 10}), and 1-5 HU (V{sub 5}). Each relative ratio per V{sub 120} was expressed as the %V{sub 15}, %V{sub 10}, and %V{sub 5}. Volumetric data-sets were compared with D-dimer, pulmonary arterial (PA) pressure, right ventricular (RV) diameter, RV/left ventricular (RV/LV) diameter ratio, PA diameter, and PA/aorta (PA/Ao) diameter ratio. The areas under the ROC curves (AUCs) were examined for their relationship to the presence of IPCs. This study was approved by the local ethics committee. Results: PA pressure and D-dimer were significantly higher in the patients who had IPCs. In the patients with IPCs, V{sub 15}, V{sub 10}, V{sub 5}, %V{sub 15}, %V{sub 10}, and %V{sub 5} were also significantly higher than those without IPC (P = 0.001). %V{sub 5} had a better correlation with D-dimer (r = 0.30, P < 0.001) and RV/LV diameter ratio (r = 0.27, P < 0.001), and showed a higher AUC (0.73) than the other CT measurements. Conclusion: The volumetric evaluation by DE{sub p}CT had a correlation with D-dimer and RV/LV diameter ratio, and the relative ratio of volumetric CT measurements with a lower attenuation threshold might be recommended for the analysis of acute PE.

  11. Correlation of clinical observation and CT findings in patients with childhood hemiplegia

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Masaaki; Eda, Isematsu; Takashima, Sachio; Yamaguchi, Tomomasa (Tottori Univ., Yonago (Japan). School of Medicine); Sugitani, Akitoshi

    1984-02-01

    Of 64 cases of hemiplegia, 33 were congenital and 31 acquired. CT revealed abnormality at a high incidence, 29 cases of congenital hemiplegia (87.8%) and 29 of acquired hemiplegia (93.5%). The side with abnormal CT findings and clinical hemiplegic side were identical in 25 cases of congenital hemiplegia (86.2%) and 24 of acquired hemiplegia (82.8%), the both rates being high. With respect to the correlation between CT and clinical findings, the low density area in the cortex, rather than lateral ventricular dilatation, was more closely related to clinical findings, indicating the tendency that the more extensive the low density area, the more severe were both hemiplegia and intellectual disturbance.

  12. Xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans: correlation of xenon and CT density values with pulmonary function test results

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Yang, Dong Hyun; Seo, Joon Beom; Chae, Eun Jin; Lee, Jeongjin [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Songpa-gu, Seoul (Korea); Hong, Soo-Jong; Yu, Jinho; Kim, Byoung-Ju [University of Ulsan College of Medicine, Department of Pediatrics, Asan Medical Center, Seoul (Korea); Krauss, Bernhard [Siemens Medical Solutions AG-Computed Tomography, Forchheim (Germany)

    2010-09-15

    Xenon ventilation CT using dual-source and dual-energy technique is a recently introduced, promising functional lung imaging method. To expand its clinical applications evidence of additional diagnostic value of xenon ventilation CT over conventional chest CT is required. To evaluate the usefulness of xenon ventilation CT using dual-source and dual-energy technique in children with bronchiolitis obliterans (BO). Seventeen children (age 7-18 years; 11 boys) with BO underwent xenon ventilation CT using dual-source and dual-energy technique. Xenon and CT density values were measured in normal and hyperlucent lung regions on CT and were compared between the two regions. Volumes of hyperlucent regions and ventilation defects were calculated with thresholds determined by visual and histogram-based analysis. Indexed volumes of hyperlucent lung regions and ventilation defects were correlated with pulmonary function test results. Effective doses of xenon CT were calculated. Xenon (14.6 {+-} 6.4 HU vs 26.1 {+-} 6.5 HU; P < 0.001) and CT density (-892.8 {+-} 25.4 HU vs -812.3 {+-} 38.7 HU; P < 0.001) values were significantly lower in hyperlucent regions than in normal lung regions. Xenon and CT density values showed significant positive correlation for the entire lung in 16 children ({gamma} = 0.55 {+-} 0.17, P < 0.001 or =0.017) and for hyperlucent regions in 13 children ({gamma} = 0.44 {+-} 0.16, P < 0.001 or =0.001-0.019). Indexed volumes and volume percentages of hyperlucent lung regions and ventilation defects showed strong negative correlations with forced expiratory volume [FEV1, ({gamma} = -0.64-0.85, P {<=} 0.006)], FEV1/forced vital capacity [FVC, ({gamma} = -0.63-0.84, P {<=} 0.008)], and forced midexpiratory flow rate [FEF{sub 25-75}, ({gamma} = -0.68-0.88, P {<=} 0.002). Volume percentages of xenon ventilation defects (35.0 {+-} 16.4%)] were not significantly different from those of hyperlucent lung regions (38.2 {+-} 18.6%). However, mismatches between the

  13. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas

    Directory of Open Access Journals (Sweden)

    Almir Galvão Vieira Bitencourt

    2014-04-01

    Full Text Available Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG positron emission tomography/computed tomography (PET/CT performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm. Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%. At PET/CT, 53 (89.8% of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5. A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.

  14. Standardized perfusion value of the esophageal carcinoma and its correlation with quantitative CT perfusion parameter values

    Energy Technology Data Exchange (ETDEWEB)

    Djuric-Stefanovic, A., E-mail: avstefan@eunet.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Saranovic, Dj., E-mail: crvzve4@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Sobic-Saranovic, D., E-mail: dsobic2@gmail.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia); Masulovic, D., E-mail: draganmasulovic@yahoo.com [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Unit of Digestive Radiology (First University Surgical Clinic), Center of Radiology and MR, Clinical Center of Serbia, Belgrade (Serbia); Artiko, V., E-mail: veraart@beotel.rs [Faculty of Medicine, University of Belgrade, Belgrade (Serbia); Center of Nuclear Medicine, Clinical Center of Serbia, Belgrade (Serbia)

    2015-03-15

    Purpose: Standardized perfusion value (SPV) is a universal indicator of tissue perfusion, normalized to the whole-body perfusion, which was proposed to simplify, unify and allow the interchangeability among the perfusion measurements and comparison between the tumor perfusion and metabolism. The aims of our study were to assess the standardized perfusion value (SPV) of the esophageal carcinoma, and its correlation with quantitative CT perfusion measurements: blood flow (BF), blood volume (BV), mean transit time (MTT) and permeability surface area product (PS) of the same tumor volume samples, which were obtained by deconvolution-based CT perfusion analysis. Methods: Forty CT perfusion studies of the esophageal cancer were analyzed, using the commercial deconvolution-based CT perfusion software (Perfusion 3.0, GE Healthcare). The SPV of the esophageal tumor and neighboring skeletal muscle were correlated with the corresponding mean tumor and muscle quantitative CT perfusion parameter values, using Spearman's rank correlation coefficient (r{sub S}). Results: Median SPV of the esophageal carcinoma (7.1; range: 2.8–13.4) significantly differed from the SPV of the skeletal muscle (median: 1.0; range: 0.4–2.4), (Z = −5.511, p < 0.001). The cut-off value of the SPV of 2.5 enabled discrimination of esophageal cancer from the skeletal muscle with sensitivity and specificity of 100%. SPV of the esophageal carcinoma significantly correlated with corresponding tumor BF (r{sub S} = 0.484, p = 0.002), BV (r{sub S} = 0.637, p < 0.001) and PS (r{sub S} = 0.432, p = 0.005), and SPV of the skeletal muscle significantly correlated with corresponding muscle BF (r{sub S} = 0.573, p < 0.001), BV (r{sub S} = 0.849, p < 0.001) and PS (r{sub S} = 0.761, p < 0.001). Conclusions: We presented a database of the SPV for the esophageal cancer and proved that SPV of the esophageal neoplasm significantly differs from the SPV of the skeletal muscle, which represented a sample of healthy

  15. Utility of 18F sodium fluoride PET/CT imaging in the evaluation of postoperative pain following surgical spine fusion.

    Science.gov (United States)

    Pouldar, D; Bakshian, S; Matthews, R; Rao, V; Manzano, M; Dardashti, S

    2017-08-01

    A retrospective case review of patients who underwent 18F sodium fluoride PET/CT imaging of the spine with postoperative pain following vertebral fusion. To determine the benefit of 18F sodium fluoride PET/CT imaging in the diagnosis of persistent pain in the postoperative spine. The diagnosis of pain generators in the postoperative spine has proven to be a diagnostic challenge. The conventional radiologic evaluation of persistent pain after spine surgery with the use of plain radiographs, MRI, and CT can often fall short of diagnosis in the complex patient. 18F sodium fluoride PET/CT imaging is an alternative tool to accurately identify a patient's source of pain in the difficult patient. This retrospective study looked at 25 adult patients who had undergone 18F sodium fluoride PET/CT imaging. All patients had persistent or recurrent back pain over the course of a 15-month period after having undergone spinal fusion surgery. All patients had inconclusive dedicated MRI. The clinical accuracy of PET/CT in identifying the pain generator and contribution to altering the decision making process was compared to the use of CT scan alone. Of the 25 patients studied, 17 patients had increased uptake on the 18F sodium fluoride PET/CT fusion images. There was a high-level correlation of radiotracer uptake to the patients' pain generator. Overall 88% of the studies were considered beneficial with either PET/CT altering the clinical diagnosis and treatment plan of the patient or confirming unnecessary surgery. 18F sodium fluoride PET/CT proves to be a useful tool in the diagnosis of complex spine pathology of the postoperative patients. In varied cases, a high correlation of metabolic activity to the source of the patient's pain was observed.

  16. Central airway pathology: clinic features, CT findings with pathologic and virtual endoscopy correlation.

    Science.gov (United States)

    Barnes, Daniel; Gutiérrez Chacoff, José; Benegas, Mariana; Perea, Rosario J; de Caralt, Teresa M; Ramirez, José; Vollmer, Ivan; Sanchez, Marcelo

    2017-04-01

    To describe the imaging features of the central airway pathology, correlating the findings with those in pathology and virtual endoscopy. To propose a schematic and practical approach to reach diagnoses, placing strong emphasis on multidetector computed tomography (MDCT) findings. We reviewed our thoracic pathology database and the central airway pathology-related literature. Best cases were selected to illustrate the main features of each disease. MDCT was performed in all cases. Multiplanar and volume-rendering reconstructions were obtained when necessary. Virtual endoscopy was obtained from the CT with dedicated software. Pathological conditions affecting the central airways are a heterogeneous group of diseases. Focal alterations include benign neoplasms, malignant neoplasms, and non-neoplastic conditions. Diffuse abnormalities are divided into those that produce dilation and those that produce stenosis and tracheobronchomalacia. Direct bronchoscopy (DB) visualises the mucosal layer and is an important diagnostic and therapeutic weapon. However, assessing the deep layers or the adjacent tissue is not possible. MDCT and post-processing techniques such as virtual bronchoscopy (VB) provide an excellent evaluation of the airway wall. This review presents the complete spectrum of the central airway pathology with its clinical, pathological and radiological features. • Dividing diseases into diffuse and focal lesions helps narrow the differential diagnosis. • Focal lesions with nodularity are more likely to correspond to tumours. • Focal lesions with stenosis are more likely to correspond to inflammatory disease. • Posterior wall involvement is the main feature in diffuse lesions with stenosis.

  17. Tegmental-type primary pontine hemorrhage with mesencephalic extension. Clinico-CT-anatomic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Goto, Noboru; Ishikawa, Hiroshi; Kaneko, Mitsuo; Tanaka, Keisei

    1983-06-01

    In nine autopsy cases of tegmental-type primary pontine hemorrhage, two cases with a mesencephalic extension which was not accurately diagnosed symptomatologically, but which was clearly detected on CT films, were found. Correlative clinico-CT-anatomic reports on this kind of pontine hemorrhage have not been included in the literature. The two patients were both females, 73 and 53 years old. Both were hypertensive and under medical care. They showed disturbances of consciousness and respiration, pin-point pupils, fixed eyes in the midposition, right hemiplegia, right extensor plantar response, etc., but both responded well to painful stimuli on the left half of the body. CT examinations detected a continuous high-density area in the left-sided tegmentum of the pons and midbrain. They died 9 and 21 days later respectively. With the help of an electronic image analyser, a great volume of hematoma was measured in the postmortem brainstem in these cases (17 ml and 14 ml). Precise analyses of the correlations among clinical symptomatology, CT, and anatomical findings, and histological examinations were carried out in an attempt to find the pathogenesis of this disease. In the diagnosis of tegmental-type primary pontine hemorrhage, attention should be paid to a possible mesencephalic involvement as one of the modes of hematoma extension, although it may be rather rare.

  18. Primary pulmonary cryptococcosis: evaluation of CT characteristics in 26 immunocompetent Chinese patients

    Energy Technology Data Exchange (ETDEWEB)

    Qu, Yanjuan; Liu, Guobing; Ghimire, Prasanna; Liao, Meiyan; Xu, Liying [Dept. of Radiology, Zhongnan Hospital of Wuhan Univ., Wuhan (China)], E-mail: leometeor123@gmail.com; Shi, Heshui [Dept. of Radiology, Union Hospital affiliated to Tongji Medical College of Huazhong Univ. of Science and Technology, Wuhan (China); Yang, Guifang [Dept. of Pathology, Zhongnan Hospital of Wuhan Univ., Wuhan (China); Wang, Guanliang [Dept. of Radiology, Taizhou Hospital of Zhejiang Province, Taizhou (China)

    2012-07-15

    Background. Discrepancies still exist in the diagnosis of primary pulmonary cryptococcosis in immunocompetent patients. Purpose. To describe and evaluate radiological manifestations of pulmonary cryptococcosis in immunocompetent patients. Material and Methods. Twenty-six histopathologically confirmed cases of pulmonary cryptococcosis were analyzed for clinical, pathological, and CT characteristics. Necessary statistical tests for differences in CT presentations and correlation analysis between clinical and CT characteristics were performed. Results. The patients' ages ranged from 24 to 79 years, with 20 men and six women. Eighteen patients were symptomatic, with cough as the most common symptom (n = 14, 53.8%). Nodules (n = 21, 80.8%) were the most common CT findings. Eight cases presented with solitary and nine with multiple nodules, while 13 cases presented with irregular and 19 with ill-defined nodules. The halo sign was demonstrated, encompassing nodules in 14 of the 21 patients. Lesions were mainly localized in the lower lobes of the lungs (n = 15, 57.7%) with peripheral distribution (n = 18, 69.2%). Ground-glass opacities (GGOs) were more easily detected in older patients (66.7%, P <0.01). No significant differences in CT abnormalities were found between male and female patients. Conclusion. Primary pulmonary cryptococcosis in immunocompetent patients exhibits certain CT characteristics. The typical presentation includes multiple nodules with the halo sign scattered in the peripheral field in the lower lobes of the bilateral lungs. This could contribute to diagnosis of the disease entity. However, vigilance should be exercised when facing GGOs, with or without nodules, in older patients.

  19. Evaluation of contrast-enhanced helical hydro-CT in staging gastric cancer

    Institute of Scientific and Technical Information of China (English)

    Wen-Zhou Wei; Jie-Ping Yu; Jun Li; Chang-Sheng Liu; Xiao-Hua Zheng

    2005-01-01

    AIM: To discuss the helical computed tomography (CT) characteristics of gastric cancer and evaluate the diagnostic value of contrast-enhanced helical hydro-CT (HHCT) in staging gastric cancer.METHODS: A total of 50 patients with gastric cancer were included in this study. The CT findings in them were retrospectively analyzed and correlated with pathologic findings at surgery. All patients were preoperatively imaged by plain and contrast-enhanced helical CT after orally ingesting 1 000-1 500 mL water. Peristalsis was minimized by intra-venous administration of spasmolytics.RESULTS: The foci of gastric cancer became more prominent in all the 50 patients and showed strong enhancement in contrast-enhanced HHCT. The tumor was located at the gastric cardia in 14 cases, at the gastric fundus in 3 cases, at the gastric body in 8 cases, at the gastric antrum in 4 cases, at the gastric fundus and the body in 8 cases, at the gastric body and antrum in 11 cases, and at three segments of the stomach in 2 cases.The CT features of gastric cancer were focal or diffuse mural thickening, soft tissue mass, cancerous ulcer, stenosis of stomach, infiltration to adjacent tissues, lymph node and distant metastases. Strong contrast enhancement of the gastric wall was closely related to gastric cancer. The accuracy rate of contrast-enhanced HHCT in staging gastric cancer was 86% (43/50). The detection rate of lymph node metastases by CT was 60% (12/20).CONCLUSION: Contrast-enhanced HHCT is a reliable method to diagnose and stage gastric cancer.

  20. Correlation of histological findings from a large ciliochoroidal melanoma with CT perfusion and 3T MRI dynamic enhancement studies

    Directory of Open Access Journals (Sweden)

    Jose S Pulido

    2008-06-01

    Full Text Available Jose S Pulido1, Norbert G Campeau2, Ernst Klotz3, Andrew N Primak2, Osama Saba3, Kaan Gunduz1, Herbert Cantrill5, Diva Salomão1,4, Cynthia H McCollough21Department of Ophthalmology; 2Department of Radiology; 3Siemens Medical Solutions, Malvern, PA, USA; 4Department of Laboratory Medicine and Pathology, Mayo Clinic College of Medicine, Rochester, MN, USA; 5VitreoRetinal Surgery, Minneapolis, MN, USABackground: The initial use of a 64-slice computed tomography (CT scanner for obtaining quantitative perfusion data from a large ciliochoroidal melanoma, and correlation with 3T magnetic resonance imaging (MRI dynamic enhancement and tumor histology.Methods: The CT perfusion scan was performed using 80 kVp, 250 mA and 1-sec rotation time for 40 sec. The analysis was performed using commercial perfusion analysis software with a prototype 3-dimensional motion correction tool. Dynamic contrast-enhanced 3-Tesla MRI measured the kinetics of enhancement to estimate the vascular permeability. The time-dependent enhancement patterns were obtained using the average signal intensity using Functool analysis software. The involved globe was enucleated and microscopic evaluation of the tumor was performed.Results: The perfusion parameters blood flow, blood volume and permeability surface area product in the affected eye determined by CT perfusion analysis were 118 ml/100 ml/min, 11.3 ml/100 ml and 48 ml/100 ml/min. Dynamic MRI enhancement showed maximal intensity increase of 111%. The neoplasm was a ciliochoroidal spindle cell melanoma which was mitotically active (13 mitoses/40 hpf. Vascular loops and arcades were present throughout the tumor. The patient developed metastases within 9 months of presentation.Conclusion: Quantitative CT perfusion analysis of ocular tumors is feasible with motion correction software.Keywords: ciliochoroidal melanoma, CT perfusion imaging, MR enhancement imaging, tumor blood volume, tumor blood flow, tumor permeability

  1. Parkinsonian Symptomatology May Correlate with CT Findings before and after Shunting in Idiopathic Normal Pressure Hydrocephalus

    Directory of Open Access Journals (Sweden)

    Mitsuaki Ishii

    2010-01-01

    Full Text Available We aimed to investigate the characteristics of Parkinsonian features assessed by the unified Parkinson's disease rating scale (UPDRS and determine their correlations with the computed tomography (CT findings in patients with idiopathic normal pressure hydrocephalus (iNPH. The total score and the scores for arising from chair, gait, postural stability, and body hypokinesia in the motor examination section of UPDRS were significantly improved after shunt operations. Stepwise multiple regression analysis revealed that postural stability was the determinant of the gait domain score of the iNPH grading scale. The canonical correlation analysis between the CT findings and the shunt-responsive Parkinsonian features indicated that Evans index rather than midbrain diameters had a large influence on the postural stability. Thus, the pathophysiology of postural instability as a cardinal feature of gait disturbance may be associated with impaired frontal projections close to the frontal horns of the lateral ventricles in the iNPH patients.

  2. {sup 18F} FDG Uptake of Human Testis on PET/CT: Correlation with Age, Sex Hormones, and Vasectomy

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Eo, Jae Sun; Lee, Jong Jin; Chung, June Key; Lee, Dong Soo; Lee, Myung Chul [Seoul National Univ. Hospital, Seoul (Korea, Republic of)

    2011-12-15

    The purpose of this study was to evaluate glucose metabolism of normal human testis on {sup 18F} FDG PET/CT and to assess possible correlation among age, the serum levels of sex hormones, and vasectomy. {sup 18F} FDG PET/CT was performed in 66 normal healthy men (50.8{+-}13.6 years, range 22-81), and mean standard uptake values (SUV) of {sup 18F} FDG in testis and adductor muscle were measured. Testis muscle SUV ratios (T/M ratios) were calculated. Serum levels of total testosterone, free testosterone, estradiol, and of sex hormone binding globulin (SHBG) were measured. We searched for correlations between T/M ratios and age and the serum concentrations of sex hormones. {sup 18F} FDG PET/CT was also performed in 32 vasectomized men (55.7{+-}7.8 years, range 38-71) and 52 nonvasectomized men (55.4{+-}11.6 years, range 37-72). Mean SUVs of testis and adductor muscle were measured, and T/M ratios were calculated. A significant age related decline was found in T/M ratio (r=-0.509, p<0.0001). Serum levels of total testosterone and free testosterone were also found to be positively correlated with T/M ratio (r=-0.427, p=0.0003; r=0.435, p=0.0003, respectively). The mean SUV and T/M ratio of vasectomized men were significantly lower than those of nonvasectomized men (p<0.0378 and p=0.0001, respectively). Glucose metabolism in the testis in an adult population was found to be correlated with age, serum sex hormone level, and vasectomy history. These results indicate that testicular {sup 18F} FDG uptake may have attributed to testicular function and testicular histology. Our findings may have important implications for the interpretation of testicular {sup 18F} FDG uptake in the normal adult population.

  3. Mass and fat infiltration of intercostal muscles measured by CT histogram analysis and their correlations with COPD severity.

    Science.gov (United States)

    Park, Mi Jung; Cho, Jae Min; Jeon, Kyung Nyeo; Bae, Kyung Soo; Kim, Ho Cheol; Choi, Dae Seob; Na, Jae Boem; Choi, Ho Cheol; Choi, Hye Young; Kim, Ji Eun; Shin, Hwa Seon

    2014-06-01

    Chronic obstructive pulmonary disease (COPD) is characterized by progressive respiratory function impairment and respiratory muscle dysfunction. We hypothesized that the mass and fat infiltration of respiratory muscles correlates with COPD severity and emphysema extent. Ninety-eight male patients with COPD underwent chest computed tomography (CT) and spirometry. The mass and fat infiltrations of intercostal and latissimus muscles were quantified as the cross-sectional area (CSA) and attenuation of these muscles using CT histogram analysis. Intercostal index and latissimus index were defined as intercostal CSAs and latissimus CSAs divided by body mass index. The emphysema extent was measured as the ratio of the emphysematous lung volume to the total lung volume using a density-mask technique. Pearson correlation analyses were performed to evaluate the relationships between these parameters. Multiple regression analysis was performed using forced expiratory volume in 1 second (FEV1) as the dependent parameter and the clinical and CT data as the independent parameters. FEV1 was significantly correlated with intercostal index (r = 0.57), latissimus index (r = 0.34), intercostal attenuation (r = 0.62), and latissimus attenuation (r = 0.38). Emphysema extent was significantly correlated with intercostal index (r = -0.36) and intercostal attenuation (r = -0.50). Multiple regression analysis showed that FEV1 was predicted by intercostal attenuation (B = 0.40), intercostal CSA (B = 0.23), emphysema extent (B = -0.23), and age (B = -0.21, R(2) = 0.64, P increase in intercostal fat are associated with worsening of COPD severity. Copyright © 2014 AUR. Published by Elsevier Inc. All rights reserved.

  4. MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, F.; Habermann, C.R.; Welger, J.; Steiner, P.; Rozeh, B.; Buecheler, E. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Radiologie; Knaape, A.; Metternich, F. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Klinik und Poliklinik fuer Hals-, Nasen- und Ohrenheilkunde; Schoder, V. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Inst. fuer Mathematik und Datenverarbeitung in der Medizin

    2001-04-01

    Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good correlation in the detection of mucosal pathologies ({kappa}=0.46-0.87) and anatomic variants ({kappa}=0.55-0.86). All important anatomical structures could be evaluated sufficiently with MRI for preoperative management. Both diagnostic tools showed an unsatisfactory correlation with intraoperative findings in the ethmoidal complex and maxillary sinus ({tau}=-0.08-0.3). (orig.) [German] Zielsetzung: Einschaetzung des Stellenwertes der MRT in der Beurteilung der praeoperativen Diagnostik der chronischen Sinusitis und Vergleich mit koronarer CT und intraoperativem Befund. Material und Methodik: 42 Patientinnen mit klinischen Zeichen einer chronischen Sinusitis wurden jeweils innerhalb eines Tages mittels CT und MRT untersucht. Am Folgetag wurde eine transnasale endoskopische Operation an den Nasennebenhoehlen durchgefuehrt. Die CT erfolgte in Bauchlage und koronarer Schichtfuehrung (5 mm Schichtdicke und Tischvorschub). Die MRT wurde an einem 1,5 T-Geraet in Rueckenlage mittels Kopfspule durchgefuehrt. Eingesetzt wurden koronare Protonen-w-, T

  5. Clinical evaluation of dynamic CT scan of the pancreas

    Energy Technology Data Exchange (ETDEWEB)

    Tokuda, Masamichi

    1984-09-01

    The clinical usefulness of dynamic CT scans (DCT) of the pancreas was evaluated in 62 normal cases, 9 cases of acute pancreatitis, 24 cases of chronic pancreatitis and 43 cases of carcinoma of the pancreas. The normal pancreas was intensely and homogeneously enhanced on DCT, and peripancreatic vessels were clearly demonstrated, especially the gastroduodenal artery (98.4%). DCT was useful to demonstrate vascular lesions, associated with pancreatitis such as pseudoaneurysm. Although the carcinoma of the pancreas showed poor contrast enhancement on conventional enhanced CT (CCT), 37.2% showed intense contrast enhancement on DCT. Visualization of the gastroduodenal artery by DCT is helpful to decide the extent of tumor. DCT is superior to CCT in demonstrating collateral veins caused by tumor invasion to the portal system in carcinoma. DCT was approximately as accurate as angiography (92.6%) in evaluating tumor invasion to the portal system. DCT is a useful and minimally invasive modality in assessing the resectability of pancreatic carcinoma. DCT may eliminate angiography and surgery in unresectable cases. (author).

  6. Evaluation of hyperdense renal lesions incidentally detected on single-phase post-contrast CT using dual-energy CT

    Science.gov (United States)

    Park, Jung Jae; Park, Byung Kwan

    2016-01-01

    Objective: To investigate the utility of dual-energy CT (DECT) for differentiating between solid and benign cystic lesions presenting as hyperdense renal lesions incidentally detected on single-phase post-contrast CT. Methods: 90 hyperdense renal lesions incidentally detected on single-phase post-contrast CT were evaluated with follow-up DECT. DECT protocols included true non-contrast (TNC), DE corticomedullary and DE late nephrographic phase imaging. The CT numbers of hyperdense renal lesions were calculated on linearly blended and iodine overlay (IO) images, and the results were compared. Results: In total, 47 benign cystic and 43 solid renal lesions were analyzed. For differentiating between solid and benign cystic lesions on the two phases, the specificity and accuracy of all lesions and lesions  0.05). For all types of lesions ≥1.5 cm, the CT numbers between linearly blended and IO images and between TNC and virtual non-contrast images were not statistically different (p > 0.05). Conclusion: DECT may be useful for differentiating between solid and benign cystic lesions presenting as hyperdense renal lesions incidentally detected on single-phase post-contrast CT, particularly with the size ≥1.5 cm. Advances in knowledge: DECT may be used to characterize hyperdense renal lesions ≥1.5 cm incidentally detected on single-phase post-contrast CT, without the use of TNC images. PMID:27043480

  7. High-resolution CT with histopathological correlates of the classic metaphyseal lesion of infant abuse

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, Andy; Kleinman, Paul K. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); McDonald, Anna G. [Office of the Chief Medical Examiner, Boston, MA (United States); Rosenberg, Andrew E. [University of Miami Hospital, Department of Pathology, Miami, FL (United States); Gupta, Rajiv [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States)

    2014-02-15

    The classic metaphyseal lesion (CML) is a common high specificity indicator of infant abuse and its imaging features have been correlated histopathologically in infant fatalities. High-resolution CT imaging and histologic correlates were employed to (1) characterize the normal infant anatomy surrounding the chondro-osseous junction, and (2) confirm the 3-D model of the CML previously inferred from planar radiography and histopathology. Long bone specimens from 5 fatally abused infants, whose skeletal survey showed definite or suspected CMLs, were studied postmortem. After skeletal survey, selected specimens were resected and imaged with high-resolution digital radiography. They were then scanned with micro-CT (isotropic resolution of 45 μm{sup 3}) or with high-resolution flat-panel CT (isotropic resolutions of 200 μm{sup 3}). Visualization of the bony structures was carried out using image enhancement, segmentation and isosurface extraction, together with volume rendering and multiplanar reformatting. These findings were then correlated with histopathology. Study of normal infant bone clarifies the 3-D morphology of the subperiosteal bone collar (SPBC) and the radiographic zone of provisional calcification (ZPC). Studies on specimens with CML confirm that this lesion is a fracture extending in a planar fashion through the metaphysis, separating a mineralized fragment. This disk-like mineralized fragment has two components: (1) a thick peripheral component encompassing the SPBC; and (2) a thin central component comprised predominantly of the radiologic ZPC. By manipulating the 3-D model, the varying appearances of the CML are displayed. High-resolution CT coupled with histopathology provides elucidation of the morphology of the CML, a strong indicator of infant abuse. This new information may prove useful in assessing the biomechanical factors that produce this strong indicator of abusive assaults in infants. (orig.)

  8. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  9. CT evaluation of sigmoid plate dehiscence causing pulsatile tinnitus

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Pengfei; Lv, Han; Dong, Cheng; Wang, Zhenchang [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Niu, Yantao; Xian, Junfang [Capital Medical University, Department of Radiology, Beijing Tongren Hospital, Beijing (China)

    2016-01-15

    To evaluate the characteristics of sigmoid plate dehiscence (SPD) causing pulsatile tinnitus (PT) on CT arteriography and venography (CTA + V). Thirty PT patients treated successfully with SPD reconstruction were enrolled. Sixty asymptomatic patients were matched. The location, extent, number of SPD cases and concomitant signs, including venous outflow dominance, transverse sinus stenosis, high jugular bulb, temporal bone pneumatization, height of pituitary gland and pituitary fossa, abnormal mastoid emissary vein, were detected and compared using CTA + V. More than one SPD was found on the symptomatic side in 13/30 PT patients (43.3 %). The upper segment of the sigmoid plate was involved in 29/44 SPDs in the vertical direction (65.9 %); the lateral wall was involved in 38/44 SPDs in the horizontal direction (86.4 %). Singular SPD was detected in 3/60 asymptomatic patients (1.67 ± 0.35 mm{sup 2}), less so in PT patients (7.97 ± 5.17 mm{sup 2}). Compared with the control group, ipsilateral venous outflow dominance, high jugular bulb and bilateral transverse sinus stenosis were more common in the PT group, together with deeper pituitary fossa and flatter pituitary glands. SPD causing PT has characteristic CT findings. It may be generated by vascular or intracranial pressure abnormalities and act as a common key to triggering PT's perception. (orig.)

  10. Small hepatocellular carcinoma with peripheral enhancement:pathological correlation with dual phase images by helical CT

    Institute of Scientific and Technical Information of China (English)

    ZHENG Ke-guo; SHEN Jing-xian; WANG Gen-shu; XU Da-sheng

    2007-01-01

    Background The peripheral enhancement of small hepatocellular carcinoma (SHCC) is a rare appearance in dual phase images by helical computed tomography (CT). This study discusses this phenomenon and its correlative histopathology.Methods The helical CT dual phase appearance of peripheral enhancement in SHCC was analyzed in 21 cases (22 lesions). All lesions were confirmed as SHCC by histopathological examination.Results In these 22 lesions, enhanced peripheral ring in 20 lesions was incomplete, the thickness of enhanced peripheral ring varied and mural node could be found in hepatic arterial phase; only 2 lesions had complete peripheral ring enhancement and ring of uniform thickness in hepatic arterial phase. The enhancement of some peripheral rings and mural nodes dropped to very low density in portal venous phase. The tumour cells were grade Ⅰ in 3 lesions, Ⅱ in 16, Ⅲ in 2 and Ⅳ in 1. The vascular supply was more abundant at the border than in the centre of 15 lesions and the vascular supply was deficient in both centre and border of the remaining 7 lesions. In 3 lesions, the pseudocapsule showed in the border of the lesion. In 12 lesions, flecks of necrosis were found in the border and/or centre of the lesion.Conclusions The characteristic peripheral enhancement in helical CT dual phase images of small hepatocellular carcinoma correlates with different vascular supplies, fibrous capsule and necrosis of the lesion.

  11. Multimodality correlations of patellar height measurement on X-ray, CT, and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Pearlene P.; Chalian, Majid; Carrino, John A.; Eng, John; Chhabra, Avneesh [Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD (United States)

    2012-10-15

    To investigate whether the universally accepted range of normal patellar height ratios derived from radiography for the Insall-Salvati (IS) and Blackburne-Peel (BP) methods could be similarly applied to both CT and MRI. Institutional review board approval was obtained with waiver of informed consent for this HIPPA-compliant study. A total of 45 knees in 42 patients (15 men, 27 women; age range 11 to 75 years, mean age 39 {+-} 20 years) who underwent tri-modality (radiograph, CT, and MRI) examinations were selected. All patients had knee imaging obtained for a variety of reasons and measurements were performed by two independent readers who were blinded to each other's measurements or the respective measurements derived from each of the methods. Paired t test was used to compare the mean values among the modalities. Inter-observer and inter-method agreements were assessed using intra-class correlation coefficients. Statistically significant, but small quantitative differences are noted between tri-modality patellar height ratios. For comparable results, the small addition of 0.13 and 0.10 are needed for the Insall-Salvati measurements on MRI and CT respectively, compared with radiographs. For the Blackburne-Peel ratio, an additional adjustment of 0.09 is needed between radiographs and MRI, but not between radiographs and CT. These adjustments are independent of gender. The interobserver reproducibility was excellent (ICC {>=} 0.94) for both the Insall-Salvati and Blackburne-Peel methods for all modalities. The results indicate that cut-off values for patella alta and baja derived from radiographs should not be directly transposed to CT and MRI; however, the adjustments are relatively minor. These measurements show excellent reproducibility for all modalities currently used for patellar height measurements. (orig.)

  12. Evaluation of radiation dose in 64-row whole-body CT of multiple injured patients compared to 4-row CT; Evaluation der Strahlendosis bei Polytrauma-CT-Untersuchungen eines 64-Zeilen-CT im Vergleich zur 4-Zeilen-CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrieder, A.; Geyer, L.L.; Koerner, M.; Deak, Z.; Wirth, S.; Reiser, M.; Linsenmaier, U. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie

    2012-05-15

    Purpose: To evaluate radiation exposure in whole-body CT (WBCT) of multiple injured patients comparing 4-row multidetector computed tomography (MDCT) to 64-row MDCT. Materials and Methods: 200 WBCT studies were retrospectively evaluated: 92 4-row MDCT scans and 108 64-row MDCT scans. Each CT protocol was optimized for the particular CT system. The scan length, CT dose index (CTDI), and dose length product (DLP) were recorded and analyzed for radiation exposure. The mean effective dose was estimated based on conversion factors. Student's t-test was used for statistical analysis. Results: The mean CTDI{sub vol} values (mGy) of the thorax and abdomen were significantly reduced with 64-row MDCT (10.2 {+-} 2.5 vs. 11.4 {+-} 1.4, p < 0.001; 14.2 {+-} 3.7 vs. 16.1 {+-} 1.7, p < 0.001). The DLP values (mGy x cm) of the head and thorax were significantly increased with 64-row MDCT (1305.9 {+-} 201.1 vs. 849.8 {+-} 90.9, p < 0,001; 504.4 {+-} 134.4 vs. 471.5 {+-} 74.1, p = 0.030). The scan lengths (mm) were significantly increased with 64-row MDCT: head 223.6 {+-} 35.8 vs. 155.5 {+-} 12.3 (p < 0.001), thorax 427.4 {+-} 44.5 vs. 388.3 {+-} 57.5 (p < 0.001), abdomen 520.3 {+-} 50.2 vs. 490.8 {+-} 51.6 (p < 0.001). The estimated mean effective doses (mSv) were 22.4 {+-} 2.6 (4-row MDCT) and 24.1 {+-} 4.6 (64-row MDCT; p = 0.001), resulting in a percentage increase of 8 %. Conclusion: The radiation dose per slice of the thorax and abdomen can be significantly decreased by using 64-row MDCT. Due to the technical advances of modern 64-row MDCT systems, the scan field can be adapted to the clinical demands and, if necessary, enlarged without time loss. As a result, the estimated mean effective dose might be increased in WBCT. (orig.)

  13. Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gondim Teixeira, Pedro Augusto; Formery, Anne-Sophie; Blum, Alain [CHRU-Nancy Hopital Central, Service d' Imagerie Guilloz, Nancy (France); Hossu, Gabriela [Universite de Lorraine, IADI U947, Nancy (France); INSERM, CIC-IT 1433, Nancy (France); Winninger, Daniel [IDCmem, Nancy (France); Batch, Toufik [Hopital de Mercy, Service de Radiologie, Metz (France); Gervaise, Alban [Legouest Military Instruction Hospital, Medical Imaging Department, Metz (France)

    2017-02-15

    To establish evidence-based recommendations for musculoskeletal kinematic 4D-CT on wide area-detector CT. In order to assess factors influencing image quality in kinematic CT studies, a phantom consisting of a polymethylmethacrylate rotating disk with round wells of different sizes was imaged with various acquisition protocols. Cadaveric acquisitions were performed on the ankle joint during motion in two different axes and at different speeds to allow validation of phantom data. Images were acquired with a 320 detector-row CT scanner and were evaluated by two readers. Motion artefacts were significantly correlated with various parameters (movement axis, distance to centre, rotation speed and volume acquisition speed) (p < 0.0001). The relation between motion artefacts and distance to motion fulcrum was exponential (R{sup 2} 0.99). Half reconstruction led to a 23 % increase in image noise and a 40 % decrease in motion artefacts. Cadaveric acquisitions confirmed phantom data. Based on these findings, high tube rotation speed and half reconstruction are recommended for kinematic CT. The axis of motion significantly influences image artefacts and should be considered in patient training and evaluation of acquisition protocol suitability. This study provides evidence-based recommendations for musculoskeletal kinematic 4D-CT. (orig.)

  14. Lesion area detection using source image correlation coefficient for CT perfusion imaging.

    Science.gov (United States)

    Fan Zhu; Rodriguez Gonzalez, David; Carpenter, Trevor; Atkinson, Malcolm; Wardlaw, Joanna

    2013-09-01

    Computer tomography (CT) perfusion imaging is widely used to calculate brain hemodynamic quantities such as cerebral blood flow, cerebral blood volume, and mean transit time that aid the diagnosis of acute stroke. Since perfusion source images contain more information than hemodynamic maps, good utilization of the source images can lead to better understanding than the hemodynamic maps alone. Correlation-coefficient tests are used in our approach to measure the similarity between healthy tissue time-concentration curves and unknown curves. This information is then used to differentiate penumbra and dead tissues from healthy tissues. The goal of the segmentation is to fully utilize information in the perfusion source images. Our method directly identifies suspected abnormal areas from perfusion source images and then delivers a suggested segmentation of healthy, penumbra, and dead tissue. This approach is designed to handle CT perfusion images, but it can also be used to detect lesion areas in magnetic resonance perfusion images.

  15. FDG PET/CT in Crohn's disease: correlation of quantitative FDG PET/CT parameters with clinical and endoscopic surrogate markers of disease activity

    Energy Technology Data Exchange (ETDEWEB)

    Saboury, Babak; Salavati, Ali; Brothers, Alex; Basu, Sandip; Torigian, Drew A. [University of Pennsylvania School of Medicine, Department of Radiology, Philadelphia, PA (United States); Kwee, Thomas C.; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine, Liege (Belgium); Louis, Edouard [University Hospital of Liege, Division of Gastroenterology, Liege (Belgium); Alavi, Abass [University of Pennsylvania School of Medicine, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States)

    2014-04-15

    The aim of this study was to determine the feasibility and potential clinical utility of assessment of Crohn's disease (CD) activity by {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT employing a new quantitative approach. A total of 22 subjects (mean age 37) with CD who had undergone FDG PET/CT followed by ileocolonoscopy within 1 week were included in this analysis. The CD endoscopy index of severity (CDEIS) for various bowel segments was calculated. The CD activity index (CDAI) was evaluated, and fecal calprotectin was measured. On PET, regions with increased FDG uptake in large bowel were segmented with an adaptive contrast-oriented thresholding algorithm, and metabolically active volume (MAV), uncorrected mean standardized uptake value (SUV{sub mean}), partial volume-corrected SUV{sub mean} (PVC-SUV{sub mean}), SUV{sub max}, uncorrected total lesion glycolysis (TLG = MAV x SUV{sub mean}), and PVC total lesion glycolysis (PVC-TLG = MAV x PVC-SUV{sub mean}) were measured. Global CD activity score (GCDAS) was calculated as the sum of PVC-TLG over all clinically significant FDG-avid regions in each subject. Correlations between regional PET quantification measures (SUVs, TLGs) and CDEIS were calculated. Correlations between the global PET quantification measure (GCDAS, global SUVs) with CDAI, fecal calprotectin, CDEIS, and CRP level were also calculated. SUV{sub max}, PVC-SUV{sub mean}, and PVC-TLG significantly correlated with segment CDEIS subscores (r = 0.50, r = 0.69, and r = 0.31, respectively; p < 0.05). GCDAS significantly correlated with CDAI and fecal calprotectin (r = 0.64 and r = 0.51, respectively; p < 0.05). By employing this new quantitative approach, we were able to calculate indices of regional and global CD activity, which correlated well with both clinical and pathological disease activity surrogate markers. This approach may be of clinical importance in measuring both global disease activity and treatment response

  16. Spectral CT evaluation of interstitial brachytherapy in pancreatic carcinoma xenografts: preliminary animal experience

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Shudong [Jiangsu University, Department of Radiology, The Affiliated Renmin Hospital, Zhenjiang, Jiangsu (China); Shanghai Jiao tong University, School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Huang, Wei; Song, Qi; Lin, Xiaozhu; Wang, Zhongmin; Chen, Kemin [Shanghai Jiao tong University, School of Medicine, Department of Radiology, Ruijin Hospital, Shanghai (China); Chen, Yerong [Jiangsu University, Department of Radiology, The Affiliated Renmin Hospital, Zhenjiang, Jiangsu (China)

    2014-09-15

    We sought to evaluate the capability of spectral CT to detect the therapeutic response to {sup 125}I interstitial brachytherapy in a pancreatic carcinoma xenograft nude mouse model. Twenty mice bearing SWl990 human pancreatic cancer cell xenografts were randomly separated into two groups: experimental (n = 10; 1.0 mCi) and control (n = 10; 0 mCi). After a two-week treatment, spectral CT was performed. Contrast-to-noise ratio (CNR) and iodine concentration (IC) in the lesions were measured and normalized to the muscle tissue, and nIC CD31 immunohistochemistry was used to measure microvessel density (MVD). The relationships between the nIC and MVD of the tumours were analysed. The nIC of the experimental group was significantly lower than that of the control group during the multiphase examination. A significant difference in the MVD was observed between the two groups (P <0.001). The nIC values of the three-phase scans have a certain positive correlation with MVD (r = 0.57, p < 0.0001; r = 0.48, p = 0.002; r = 0.63, p = 0.0017 in the 10, 25, and 60 s phase, respectively). Spectral CT can be a useful non-invasive imaging modality in evaluating the therapeutic effect of {sup 125}I interstitial brachytherapy to a pancreatic carcinoma. (orig.)

  17. Helical CT in the primary trauma evaluation of the cervical spine: an evidence-based approach

    Energy Technology Data Exchange (ETDEWEB)

    Blackmore, C.C. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Center for Cost and Outcomes Research, Univ. of Washington, Seattle (United States); Dept. of Radiology, Harborview Medical Center, Seattle, WA (United States); Mann, F.A. [Washington Univ., Seattle, WA (United States). Dept. of Radiology; Harborview Injury Prevention and Research Center, University of Washington, Seattle (United States); Wilson, A.J. [Washington Univ., Seattle, WA (United States). Dept. of Radiology

    2000-11-01

    This review provides a summary of the cost-effectiveness, clinical utility, performance, and interpretation of screening helical cervical spine CT for trauma patients. Recent evidence supports the use of helical CT as a cost-effective method for screening the cervical spine in high-risk trauma patients. Screening cervical spine CT can be performed at the time of head CT to lower the cost of the evaluation, and when all short- and long-term costs are considered, CT may actually save money when compared with traditional radiographic screening. In addition to having higher sensitivity and specificity for cervical spine injury, CT screening also allows more rapid radiological clearance of the cervical spine than radiography. Patients who are involved in high-energy trauma, who sustain head injury, or who have neurological deficits are candidates for CT screening. Screening with CT may enhance detection of other potentially important injuries of the cervical region. (orig.)

  18. CT Features and Pathological Correlation of Primitive Neuroectodermal Tumor of the Kidney.

    Science.gov (United States)

    Dong, Junqiang; Xing, Jingjing; Limbu, Hangsha Hang; Yue, Songwei; Su, Lei; Zhang, Dandan; Gao, Jianbo

    2015-09-01

    The purpose of the study was to analyze the computed tomography (CT) findings of primitive neuroectodermal tumor (PNET) of the kidney and correlate them pathologically. Ten cases of pathologically confirmed renal PNET were collected and retrospectively reviewed. The CT features that were analyzed include tumor size, shape, margins, density, nature of enhancement, presence of thrombosis, and metastasis, etc. These parameters were correlated with pathological findings and combined with literature review. The median age of the patients was 30 years. CT images showed solitary, large, ill-defined, irregular, or lobulated heterogeneous mass. Invasive growth toward the renal cortex and pelvis with renal cortical interruptions were seen in eight cases with one case exhibiting invasion that extended beyond the renal capsule with soft tissue seen in the perirenal fat pace. The tumors were confined to the kidney contour with enlargement of kidney in six of the cases. Cystic changes with mural nodules were detected in three cases. Eight cases showed persistent moderate enhancement during the nephrographic phase. Irregular septum-like structures were seen in four cases. Thrombosis was detected in eight cases. Lymph node metastasis was detected in eight cases with bilateral lung metastasis in two and bone metastasis in one. Renal PNET is a rare highly aggressive disease affecting younger people. It should be considered as a strong differential when well confined, yet large tumors that cause enlargement of the kidney are seen and also when tumors expressing cystic changes along with mural nodules are seen. Although renal PNET has certain other characteristic CT features, pathological and immunohistochemistry report must also be sought for definitive diagnosis.

  19. Intraductal papillary mucinous neoplasms of the pancreas: Correlation of helical CT features with pathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yu; Lin Xiaozhu; Upadhyaya, Manavendra; Song Qi [Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine (China); Chen Kemin, E-mail: keminchen@126.com [Department of Radiology, Ruijin Hospital, Shanghai Jiaotong University School of Medicine (China)

    2010-11-15

    Objective: To evaluate the CT features of intraductal papillary mucinous neoplasms of the pancreas (IPMNs), and to compare with pathological findings in order to identify CT features that can be helpful in differentiating benign IPMNs from malignant IPMNs. Materials and methods: The CT findings in 25 patients were reviewed for tumor location, tumor type, dilatation of the main pancreatic duct (MPD), MPD involvement, mural node or solid attenuating component, tumor size in branch duct or mixed duct type, dilatation of common bile duct (CBD) and invasion of surrounding structures. The data was subjected to Chi-Square Tests or Fisher's Exact Test using SPSS13.0 software with p value < 0.05 indicating significant statistical difference. Results: Presence of mural node or solid enhancing component, size of mural node or solid enhancing component {>=}7 mm, dilatation of CBD was more common in malignant IPMNs (p < 0.05). None of tumor location, tumor type, dilatation of MPD, MPD involvement, tumor size, and invasion of surrounding structures was statistically significant in differentiating benign from malignant IPMNs. Conclusions: CT features suggestive of malignant or invasive IPMNs include presence of mural node or solid enhancing component, size of mural node or solid enhancing component {>=}7 mm, and dilatation of CBD.

  20. Angiographic-CT-FDG-Pathologic Correlations of the Incidentally Discovered Adrenal Mass

    Directory of Open Access Journals (Sweden)

    Bi-Fang Lee

    2011-01-01

    Full Text Available During abdominal ultrasonography of a 37-year-old man a 3.2 cm hypoechoic mass in the right hepatic lobe was found incidentally. This prompted an abdominal CT, an FDG PET/CT, and an angiography to evaluate the nature of the mass. Laboratory data showed positive anti-HBs/anti-HBe, and negative HCV antibody. The alfa-fetoprotein and liver function tests were within normal limits. Contrast-enhanced CT found an enhanced hepatic tumor and primary hepatocellular carcinoma was suspected. PET/CT revealed no abnormal FDG accumulation in the right hepatic mass. The digital subtraction angiographies of the right inferior phrenic artery and right renal artery revealed a hypervascular tumor in the right adrenal gland. Therefore, a diagnosis of a right adrenal tumor was made. Serum aldosterone, serum cortisol, and urine vanillylmandelic acid, and catecholamine were all within normal limits. Laparoscopic right adrenalectomy was performed and adrenal cortical adenoma was diagnosed on a histological study.

  1. Correlation of intra-tumor 18F-FDG uptake heterogeneity indices with perfusion CT derived parameters in colorectal cancer.

    Directory of Open Access Journals (Sweden)

    Florent Tixier

    Full Text Available Thirty patients with proven colorectal cancer prospectively underwent integrated 18F-FDG PET/DCE-CT to assess the metabolic-flow phenotype. Both CT blood flow parametric maps and PET images were analyzed. Correlations between PET heterogeneity and perfusion CT were assessed by Spearman's rank correlation analysis.Blood flow visualization provided by DCE-CT images was significantly correlated with 18F-FDG PET metabolically active tumor volume as well as with uptake heterogeneity for patients with stage III/IV tumors (|ρ|:0.66 to 0.78; p-value<0.02.The positive correlation found with tumor blood flow indicates that intra-tumor heterogeneity of 18F-FDG PET accumulation reflects to some extent tracer distribution and consequently indicates that 18F-FDG PET intra-tumor heterogeneity may be associated with physiological processes such as tumor vascularization.

  2. Computer aided breast density evaluation in cone beam breast CT

    Science.gov (United States)

    Zhang, Xiaohua; Ning, Ruola

    2011-03-01

    Cone Beam Breast CT is a three-dimensional breast imaging modality with high contrast resolution and no tissue overlap. With these advantages, it is possible to measure volumetric breast density accurately and quantitatively with CBBCT 3D images. Three major breast components need to be segmented: skin, fat and glandular tissue. In this research, a modified morphological processing is applied to the CBBCT images to detect and remove the skin of the breast. After the skin is removed, a 2-step fuzzy clustering scheme is applied to the CBBCT image volume to adaptively cluster the image voxels into fat and glandular tissue areas based on the intensity of each voxel. Finally, the CBBCT breast volume images are divided into three categories: skin, fat and glands. Clinical data is used and the quantitative CBBCT breast density evaluation results are compared with the mammogram-based BIRADS breast density categories.

  3. Asbestosis and other pulmonary fibrosis in asbestos-exposed workers: high-resolution CT features with pathological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Arakawa, Hiroaki [Dokkyo Medical University, Department of Radiology, Mibu, Tochigi (Japan); Kishimoto, Takumi [Okayama Rosai Hospital, Asbestos Research Center, Okayama (Japan); Ashizawa, Kazuto [Nagasaki University Graduate School of Biomedical Sciences, Department of Clinical Oncology, Nagasaki (Japan); Kato, Katsuya [Kawasaki Medical School, Department of Diagnostic Radiology 2, Okayama (Japan); Okamoto, Kenzo [Hokkaido Chuo Hospital, Department of Pathology, Iwamizawa, Hokkaido (Japan); Honma, Koichi [Dokkyo Medical University, Department of Pathology, Mibu, Tochigi (Japan); Hayashi, Seiji [National Hospital Organization Kinki-Chuo Chest Medical Center, Osaka (Japan); Akira, Masanori [National Hospital Organization Kinki-Chuo Chest Medical Center, Department of Radiology, Osaka (Japan)

    2016-05-15

    The purpose was to identify distinguishing CT features of pathologically diagnosed asbestosis, and correlate diagnostic confidence with asbestos body burden. Thirty-three workers (mean age at CT: 73 years) with clinical diagnoses of asbestosis, who were autopsied (n = 30) or underwent lobectomy (n = 3), were collected. Two radiologists independently scored high-resolution CT images for various CT findings and the likelihood of asbestosis was scored. Two pathologists reviewed the pathology specimens and scored the confidence of their diagnoses. Asbestos body count was correlated with CT and pathology scores. Pathologically, 15 cases were diagnosed as asbestosis and 18 cases with various lung fibroses other than asbestosis. On CT, only the score of the subpleural curvilinear lines was significantly higher in asbestosis (p = 0.03). Accuracy of CT diagnosis of asbestosis with a high confidence ranged from 0.73 to 0.79. Asbestos body count positively correlated with CT likelihood of asbestosis (r = 0.503, p = 0.003), and with the confidence level of pathological diagnosis (r = 0.637, p < 0.001). Subpleural curvilinear lines were the only clue for the diagnosis of asbestosis. However, this was complicated by other lung fibrosis, especially at low asbestos body burden. (orig.)

  4. [CT-expo--a novel program for dose evaluation in CT].

    Science.gov (United States)

    Stamm, G; Nagel, H D

    2002-12-01

    CT-Expo is a novel MS Excel application for assessing the radiation doses delivered to patients undergoing CT examinations, based on computational methods that were used to analyze the data collected in the German survey on CT practice in 1999. The program enables the calculation of all dose quantities of practical value, such as axial dose free-in-air, weighted CTDI, dose-length product, effective dose and uterine dose. In contrast to existing programs for CT dose assessment, CT-Expo offers a number of unique features, such as gender-specific dose calculation for all age groups (adults, children, newborns), applicability to all existing scanner models including correction of scanner-specific influences, and the possibility of comparison with the results from the German CT survey on CT practice. Three different application modules offer free and standardized dose calculations as well as a comprehensive benchmarking section including guidance on dose optimization. The program is available as shareware in both German and English version. Additional information and a demo version free of charge can be requested via e-mail from the author's address stamm.georg@mh-hannover. de) or from the web page http://www.mh-hannover.de/kliniken/radiologie/str_04.html.

  5. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  6. Multidetector row-CT in evaluation of living renal donors

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ji-qing; HU Xiao-peng; WANG Wei; LI Xiao-bei; YIN Hang; ZHANG Xiao-dong

    2010-01-01

    Background Multidetector-row CT (MDCT) has been evolving to the standard evaluating method of potential living donor in most centers, and can provide excellent details for selecting candidates and determining surgical technique.This study aimed to assess the value of MDCT in evaluation of the anatomy of living kidney donors and to reveal the prevalence of renal vascular variations in a Chinese population.Methods One hundred and four potential donors underwent MDCT and the data sets were post-processed for reformatted images with various techniques, such as maximum intensity projection (MIP), a volume-rendering technique (VR), and multiplanar reformation (MPR). Donor nephrectomies were performed on 97 candidates after MDCT evaluation with the findings during surgery constituting the standard of reference. Resulting MDCT images were compared with actual anatomy found during surgery. Results The MDCT images accurately displayed the anatomic structure of the main renal arteries and veins as well as the upper ureters, except in one case with horseshoe kidney. The prevalence of accessory arteries revealed in images was 27.2% (28/103) and early branching was found in 12.6% (13/103). Compared with findings during surgery, the detection of accessory arteries in MDCT images was 85.7% (6/7), and the detection of larger accessory arteries (>1.5 mm in diameter) was 100%. Detection of early branching was 100%.Conclusion MDCT helps accurately evaluate the renal anatomy of potential donors thus facilitating the planning of surgery.

  7. MR and CT cholangiography in evaluation of the biliary tract

    Energy Technology Data Exchange (ETDEWEB)

    Masui, T.; Fujiwara, T.; Ichijo, K.; Imaoka, I.; Naito, M. [Seirei Mikatabara General Hospital, Hamamatsu (Japan). Dept. of Radiology; Takehara, Y.; Kaneko, M. [Hamamatsu Univ. School of Medicine (Japan). Dept. of Radiology; Yamamoto, H.; Watahiki, H. [Seirei Mikatabara General Hospital, Hamamatsu (Japan). Dept. of Gastroenterology

    1998-09-01

    Objective: To compare MR and CT cholangiography (MRC and CTC) in evaluating the anatomy of the extrahepatic biliary tract and the pathology related to the gallbladder. Material and Methods: Twenty-three patients underwent MRC and CTC with a biliary contrast medium for investigation of biliary disease. 3D displays of both were also obtained. Endoscopic retrograde cholangiography was performed in 17 patients, and the pathology of all 23 was evaluated. Results: Overall, the image quality was higher with CTC than with MRC (4.7 vs 3.9, p<0.05). The cystic duct was demonstrated better by CTC than MRC (p<0.05). Multiplanar reformation (MPR) and source images provided additional information to that obtained from 3D MRC and CTC images. Gallstones were revealed in 6 patients by CTC and in 5 of these 6 by MRC. In 2 patients with cholecystitis, CTC demonstrated gallbladder wall thickening but MRC did not. In 3 patients with adenomyomatosis, MRC demonstrated Rokitansky-Aschoff sinuses (RAS) while CTC demonstrated focal gallbladder wall thickening in all 3 and RAS in 1 of them. Conclusion: Both MRC and CTC provided anatomical and pathological information about the biliary system. With both techniques, however, either MPR or source images proved necessary in addition for evaluating the biliary system anatomy and pathology. The gallbladder wall was depicted clearly in source CTC, but MRC is recommended for the evaluation of adenomyomatosis because its depicts RAS clearly. (orig.)

  8. Quantifying the usefulness of CT in evaluating seniors with abdominal pain

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Lawrence M. [Campus Box 8072, Division of Emergency Medicine, School of Medicine, Washington University, St. Louis, MO 63110 (United States)]. E-mail: lewisl@msnotes.wustl.edu; Klippel, Allen P. [Campus Box 8072, Division of Emergency Medicine, School of Medicine, Washington University, St. Louis, MO 63110 (United States); Bavolek, Rebecca A. [Campus Box 8072, Division of Emergency Medicine, School of Medicine, Washington University, St. Louis, MO 63110 (United States); Ross, Laura M. [Washington University, School of Arts and Science (United States); Scherer, Tara M. [Washington University, School of Arts and Science (United States); Banet, Gerald A. [Campus Box 8072, Division of Emergency Medicine, School of Medicine, Washington University, St. Louis, MO 63110 (United States)

    2007-02-15

    Objectives: (1) Determine if older patients with abdominal pain who receive emergency department (ED) abdominal CT have changes in diagnosis and/or disposition more often than similar patients without CT; (2) compare physician confidence in diagnosis and disposition for patients with versus without CT; (3) document factors that most influence physician's decision to order abdominal CT in this population. Methods: ED patients 60 years of age or older, with acute non-traumatic abdominal pain were enrolled over a 6-week period. Physicians documented a preliminary and final ED diagnosis and disposition, along with pre- and post-evaluation confidence levels. Decision to order CT, along with clinical information most influencing that decision, was noted. Physician confidence levels and percent change in diagnosis and disposition were compared for patients with versus without CT. Results: One hundred and twenty-six patients comprised study sample. Abdominal CT rate was 59% (95%CI, 50-67%). CT was associated with an increased change in diagnosis (46%; 95%CI, 4-58% versus 29%; 95%CI, 16-42%), but no change in disposition between patients with versus without CT. Preliminary diagnostic confidence was lower for EPs who ordered a CT than for those who did not (p < 0.001). Patient history most influenced ordering CT, whereas prior lab/imaging results most influenced not ordering CT. Conclusion: Patients with CT had a change in diagnosis more often than those without. Preliminary diagnostic confidence was lower in CT group. Percent change in disposition did not differ between groups. Physicians most often ordered CT based on history and did not order CT when other diagnostic evaluation supported a specific diagnosis.

  9. PET/CT imaging in response evaluation of patients with small cell lung cancer

    DEFF Research Database (Denmark)

    Fischer, Barbara M; Mortensen, Jann; Langer, Seppo W;

    2006-01-01

    UNLABELLED: There is an increasing amount of evidence on the usability of PET in response evaluation of non-small cell lung cancer. However, data on SCLC is scarce and mainly retrospective. This prospective study assesses the use of PET (positron emission tomography) and PET/CT in response...... evaluation of patients with small cell lung cancer (SCLC). METHODS: Assignment of early and final response was compared between PET, PET/CT, and CT in 20 patients with SCLC. Final response as assigned by CT (RECIST) served as reference. RESULTS: At response evaluation after one cycle of chemotherapy major...

  10. Comparison of neuroimaging by CT and MRI and correlation with neurological presentation in eclampsia

    Directory of Open Access Journals (Sweden)

    Megha A. Jindal

    2013-02-01

    Full Text Available Background: The objective of the study was to compare computed tomography (CT and magnetic resonance imaging (MRI findings of eclampsia patients with respect to neurological signs and symptoms. Methods: This is a prospective observational study, 25 patients of eclampsia were studied, statistical analysis was done by Fishers’ exact and chi square test. Results: All patients in our study presented with antepartum or intrapartum eclampsia with neurological features ranging from headache, altered consciousness to coma. On neuroimaging by MR transiently high T2 signal intensity in the cerebral cortex and sub cortical white matter was seen, including edema. With MR angiography generalized vasospasm was also seen in 40% cases. MRI was found to be co-relating more than CT with the neurological presentation and had 90% sensitivity and 100% sensitivity. Conclusions: Symptoms like visual blurring, loss of vision and ophthalmological signs in eclampsia suggest occipital lobe involvement. Magnetic resonance imaging abnormalities in eclampsia correlate well with clinical findings as compared to CT and can be better imaging modality in eclampsia patients. [Int J Reprod Contracept Obstet Gynecol 2013; 2(1.000: 83-87

  11. Thrombocytopenic thrombotic purpura: severe clinic with no CT, minor MRI, but a SPECT correlate

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Y. [Radiologische Abteilung, Staedtisches Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Bargemann, T. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Harten, P. [Zweite Medizinische Universitaetsklinik und Poliklinik der Christian-Albrechts-Universitaet zu Kiel, Chemnitzstr. 33, Kiel 24116 (Germany); Gutschmidt, H.-J. [Abteilung Internistische Intensivmedizin und Dialyse am Staedtischen Krankenhaus Kiel, Chemnitzstr. 33, Kiel 24116 (Germany)

    1999-07-01

    A 28-year-old woman with primarily therapy refractory TTP was followed neuroradiologically over 6 months. Despite pronounced neurological and neuropsychiatric symptoms including hemiparesis and aphasia she had unremarkable CT scans on two occasions. Three MRI exams showed no correlate for her neurological symptoms except a small petechial cortical hemorrhage in the right parietooccipital gyrus which may account for her TTP-related anxiety disorder. A cerebral HMPAO-SPECT showed long-standing right-sided hypoperfusion compatible with residual vasculature changes. The possible causes for the clinico-neuroradiological discrepancies are discussed in view of the literature.

  12. Extramedullary paraspinal hematopoiesis in thalassemia: CT and MRI evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Tsitouridis, J.; Stamos, S.; Hassapopoulou, E.; Tsitouridis, K.; Nikolopoulos, P

    1999-04-01

    We present a comparative CT and MRI study of the paraspinal extramedullary hematopoiesis in 32 thalassemic patients. The patients were classified into four groups according to the MRI and CT imaging findings. Active recent extramedullary paraspinal hematopoietic masses show soft tissue behavior in both CT and MRI. Older inactive masses reveal iron deposition or fatty replacement. Combined imaging findings of paraspinal extramedullary hematopoiesis revealed the phase of its evolution and the correct diagnosis.

  13. CT attenuation of colorectal polypoid lesions: evaluation of contrast enhancement in CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Oto, Aytekin [Department of Radiology, Hacettepe University School of Medicine, Ankara (Turkey); Department of Radiology, University of Texas Medical Branch at Galveston, 301 University Boulevard, 77555-0709, Galveston, TX (United States); Gelebek, Veli; Oguz, Berna Sayan; Deger, Ahmet; Akhan, Okan; Besim, Aytekin [Department of Radiology, Hacettepe University School of Medicine, Ankara (Turkey); Sivri, Buelent [Department of Gastroenterology, Hacettepe University School of Medicine, Ankara (Turkey)

    2003-07-01

    The aim of this study was to calculate pre- and postcontrast CT attenuation values of benign colorectal polyp and carcinoma lesions detected by virtual colonoscopy, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid in the colon. Fifteen benign polyps and 21 colorectal carcinoma lesions detected by virtual colonoscopy in 18 patients were included in our study. All of the polyps and carcinoma lesions were confirmed by colonoscopic biopsy. Measurement of CT attenuation values was performed in precontrast (supine) and postcontrast (prone) scans for each polyp and carcinoma. The CT attenuation values of residual fluid in the colon was also measured from the same location before and after intravenous contrast administration. On unenhanced CT scan mean attenuation values of benign polyps and colorectal carcinomas were 32.4 and 42.6 HU, respectively. Following contrast enhancement, mean attenuation value increased to 78.9 HU for polyps and 90.7 HU for carcinomas. Increase in the CT attenuation values of these lesions was significant (p <0.0001). Mean CT attenuation value of residual fluid before and after administration of IV contrast were 14.6 and 13.8 HU, respectively. The difference between CT attenuation value of residual fluid in the colon before and after contrast material was not significant (p =0.29). Colorectal benign polyps and carcinomas demonstrate significant enhancement following contrast administration and use of intravenous contrast material during virtual colonoscopy may help in some cases in differentiating these solid lesions from residual colonic fluid that does not enhance. (orig.)

  14. Internal disc derangement in patients with low back pain: correlation of MR imaging and provocative discography and CT discography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hye Won [Samsung Medical Center, Seoul (Korea, Republic of); Cheon, Jung Eun; Hong, Sung Hwan; Kang, Heung Sik; Lee, Ji Ho; Oh, Joo Han [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of); Jeon, Pyoung [National Health Insurance Corporation Ilsan Hospital, Goyang (Korea, Republic of)

    2004-11-01

    The aim of this study was to correlate the MR imaging abnormalities of the lumbar intervertebral discs, with emphasis being placed on the high intensity zone (HIZ) with the use of discography for pain provocation and disc morphologic evaluation of the disc. Consecutive patients with low back pain unresponsive to conservative treatment, and who were being considered for spinal fusion had MRI performed, and this was followed by lumbar discography. The MR imaging, discography and CT discography (CTD) were evaluated for all of the 19 patients. Forty-three lumbar discs in 19 patients were included in this study. The findings of MR and CTD images were evaluated retrospectively with the professional opinion and agreement of two radiologists. MR images were assessed for the presence or absence of decreased T2-wighted signal intensity, decreased disc height, annular bulging, HIZ on T2-weighted images and disc herniation. The results of pain provocation were graded as 0, nonconcordant pain; 1, definite pain, but only as part of the symptom complex; 2, concordant pain. The morphology of CTD was analyzed for presence or absence of disc degeneration, radial tearing and extravasation of the contrast agent. The presence of radial tearing was defined as contrast extension to the outer third of the annulus. The prevalence of all MR abnormalities was calculated, and the data were compared with disc morphologic characteristics and the pain response on provocative discography. We used the chi-square test to analyze the results. Grade 1 and 2 discogenic pain was observed in 8 (19%) and 12 disc levels (28%), respectively. All of the seven non-degenerated discs on MR had no pain response. The decreased SI on T2-weighted image, annular bulging and HIZ were significantly correlated with discogenic pain. Extravasation of contrast media had good correlation with annular bulging and disc herniation on MRI. Radial tearing on CT discography correlated significantly with HIZ. The HIZ was

  15. {sup 18}F-FDG PET/CT evaluation of children and young adults with suspected spinal fusion hardware infection

    Energy Technology Data Exchange (ETDEWEB)

    Bagrosky, Brian M. [University of Colorado School of Medicine, Department of Pediatric Radiology, Children' s Hospital Colorado, 12123 E. 16th Ave., Box 125, Aurora, CO (United States); University of Colorado School of Medicine, Department of Radiology, Division of Nuclear Medicine, Aurora, CO (United States); Hayes, Kari L.; Fenton, Laura Z. [University of Colorado School of Medicine, Department of Pediatric Radiology, Children' s Hospital Colorado, 12123 E. 16th Ave., Box 125, Aurora, CO (United States); Koo, Phillip J. [University of Colorado School of Medicine, Department of Radiology, Division of Nuclear Medicine, Aurora, CO (United States)

    2013-08-15

    Evaluation of the child with spinal fusion hardware and concern for infection is challenging because of hardware artifact with standard imaging (CT and MRI) and difficult physical examination. Studies using {sup 18}F-FDG PET/CT combine the benefit of functional imaging with anatomical localization. To discuss a case series of children and young adults with spinal fusion hardware and clinical concern for hardware infection. These people underwent FDG PET/CT imaging to determine the site of infection. We performed a retrospective review of whole-body FDG PET/CT scans at a tertiary children's hospital from December 2009 to January 2012 in children and young adults with spinal hardware and suspected hardware infection. The PET/CT scan findings were correlated with pertinent clinical information including laboratory values of inflammatory markers, postoperative notes and pathology results to evaluate the diagnostic accuracy of FDG PET/CT. An exempt status for this retrospective review was approved by the Institution Review Board. Twenty-five FDG PET/CT scans were performed in 20 patients. Spinal fusion hardware infection was confirmed surgically and pathologically in six patients. The most common FDG PET/CT finding in patients with hardware infection was increased FDG uptake in the soft tissue and bone immediately adjacent to the posterior spinal fusion rods at multiple contiguous vertebral levels. Noninfectious hardware complications were diagnosed in ten patients and proved surgically in four. Alternative sources of infection were diagnosed by FDG PET/CT in seven patients (five with pneumonia, one with pyonephrosis and one with superficial wound infections). FDG PET/CT is helpful in evaluation of children and young adults with concern for spinal hardware infection. Noninfectious hardware complications and alternative sources of infection, including pneumonia and pyonephrosis, can be diagnosed. FDG PET/CT should be the first-line cross-sectional imaging study in

  16. CT evaluation of solitary pulmonary nodule : value of additional HRCT scan

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Kwak Jin Young; Lee, Seung Ik; Ha, Doo Hoe [Pundang CHA General Hospital, Pochon CHA Univ. College of Medicine, Sungnam (Korea, Republic of); Kim, Tae Sung; Hwang, Jung Hwa; Lee, Kyung Soo [Samsung Medical Center, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of); Kim, Yook Yung [Ewha Womans Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-04-01

    The aim of our study was to evaluate the usefulness of high-resolution CT scans in addition to helical CT for characterizing a solitary pulmonary nodule. Our study included 49 patients with a solitary pulmonary nodule ; in each patient this was evaluated by both additional high-resolution CT and helical scanning. Images were evaluated by three independent observers, each of whom read them twice : initially with helical CT images only and then with helical images plus high-resolution CT images. After analysis, the observers recorded the following : histologic diagnosis, benignancy or malignancy of a nodule, and confidence in their diagnosis (three scales). In differentiating benign and malignant nodules, the accuracy of helical scans only was 75% (110/147 readings) whereas that of helical plus high-resolution CT scans was 82% (121/147 readings)({rho}=0.001). Correct histologic diagnosis was made in 47% of cases (69/147 readings) when helical scans only had been evaluated and in 48% of cases (71/147 readings) for which both helical and high-resolotion CT scans were available ({rho}=0.815). Diagnosis was more often highly confident on the basis of additional high-resolution CT scans (25%) than helical scans only (5%) ({rho}=0.001). By enhancing differential diagnostic accuracy between benign and malignant nodules and by increasing confidence in the histologic diagnosis of a pulmonary nodule, additional high-resolution CT scans are valuable for the evaluation of a solitary pulmonary nodule.

  17. CT, MRI, and FDG-PET/CT imaging findings of abdominopelvic desmoplastic small round cell tumors: Correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Weidong, E-mail: dongw.z@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Li Chuanxing, E-mail: lichuanh@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Liu Qingyu, E-mail: liu.qingyu@163.com [Department of Radiology, No. 2 Affiliated Hospital, 107 Yanjiangxi Road, Sun Yat-sen University, Guangzhou, Guangdong 510120 (China); Hu Yingying, E-mail: yingyinghu1981@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Cao Yun, E-mail: caoyun@mail.sysu.edu.cn [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China); Department of Pathology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China); Huang Jinhua, E-mail: drhuangjh@163.com [State Key Laboratory of Oncology in South China, 651 Dongfengdong Road, Guangzhou, Guangdong 510060 (China) and Department of Radiology, Cancer Center, Sun Yat-sen University, Guangzhou, Guangdong 510060 (China)

    2011-11-15

    Objective: To analyze computed tomography (CT), magnetic resonance imaging (MRI), and fluorodeoxyglucose-positron emission tomography (FDG-PET)/CT imaging features of abdominopelvic desmoplastic small round cell tumor (DSRCT) and to improve the diagnostic efficacy of these techniques for the detection of such tumor. Methods: We retrospectively analyzed 7 cases of abdominopelvic DSRCT confirmed by histopathologic analysis. Among the 7 patients, 5 patients had undergone CT scanning, 2 of which were also examined with FDG-PET/CT imaging, and 2 had undergone MRI. Unenhanced and contrast-enhanced examinations were performed in all patients, and 2 patients had also undergone dynamic CT contrast-enhanced examinations. Image characteristics, such as shape, size, number, edge, attenuation, and intensity of each lesion before and after contrast enhancement were analyzed and compared with the pathomorphology of the tumors. Results: Multiple large masses in the abdominopelvis were detected in 6 cases, and a large mass in the pelvis was detected in 1 case. Six cases showed largest mass in pelvis, and 1 case in mesentery. None of the masses had a definite organ origin. CT showed soft tissue masses with patchy foci of hypodense areas. MR T1-weighted images revealed lesions with mild hypointense areas and patchy hypointense areas in 2 cases and lesions with patchy hyperintense areas in 1 case. T2-weighted images showed lesions with mixed isointense and hyperintense areas in 1 case and lesions with mixed hypointense, isointense, and hyperintense areas in another. Contrast-enhanced CT and T1-weighted images showed mildly heterogeneous enhancement of the lesions. Other associated findings included peritoneal seeding (n = 3), peritoneal effusions (n = 3), hepatic metastasis (n = 2), bone metastasis (n = 1), and mesenteric and retroperitoneal lymphadenopathy (n = 4). FDG-PET/CT showed multiple nodular foci of increased metabolic activity in the abdominopelvic masses, in the hepatic and

  18. Comparison of bone histomorphometry and μCT for evaluating bone quality in tail-suspended rats

    Science.gov (United States)

    Sun, Lian-Wen; Huang, Yun-Fei; Wang, Ying; Luan, Hui-Qin; Fan, Yu-Bo

    2014-10-01

    Astronauts often suffer from microgravity-induced osteoporosis due to their time in space. Bone histomorphometry, the 'gold standard' technique for detecting bone quality, is widely used in the evaluation of osteoporosis. This study investigates whether μCT has the same application value as histomorphometry in the evaluation of weightlessness-induced bone loss. A total of 24 SD rats were distributed into three groups (n = 8, each): tail-suspension (TS), TS plus active exercise (TSA), and control (CON). After 21 days, bone mineral density (BMD) was measured by dual energy X-ray absorptiometry (DXA) and μCT, and microstructure was measured by μCT and histomorphometry. BMD was found to have decreased significantly in TS and TSA compared with the CON group. The results of the μCT measurements showed that a change in BMD mainly occurred in the trabecular bone, and the trabecular BMD increased significantly in the TSA compared with the TS group. The comparison of μCT and histomorphometry showed that TS led to a significant decrease in bone volume (BV/TV), trabecular thickness (Tb.Th) and trabecular number (Tb.N), and it led to an increase in trabecular separation (Tb.Sp). However, active exercise can prevent these changes. Significant differences in most parameters between TSA and CON were found by μCT but not by histomorphometry. Additionally, the parameters of these two methods are highly correlated. Therefore, the application value of μCT is as good as histomorphometry and DXA in the diagnosis of weightlessness-induced osteoporosis and is even better in evaluating the efficacy of exercise.

  19. Acute and repeated inhalation lung injury by 3-methoxybutyl chloroformate in rats: CT-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Yeon Soo [Department of Radiology, Holy Family Hospital, College of Medicine, Catholic University of Korea, 2, Sosa-dong, Wonmi-gu, Pucheon, Kyung gi-do 420-717 (Korea, Republic of); Chung, Myung Hee [Department of Radiology, Holy Family Hospital, College of Medicine, Catholic University of Korea, 2, Sosa-dong, Wonmi-gu, Pucheon, Kyung gi-do 420-717 (Korea, Republic of)]. E-mail: mhchung@catholic.ac.kr; Park, Seog Hee [Department of Radiology, Kangnam St. Mary Hospital, Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-040 (Korea, Republic of); Kim, Hyeon-Yeong [Industrial Chemicals Research Center, Industrial Safety and Health Research Institute KISCO, 104-8, Moonji-dong, Yusong-gu, Taejon-si 305-380 (Korea, Republic of); Choi, Byung Gil [Department of Radiology, Kangnam St. Mary Hospital, Catholic University of Korea, 505 Banpo-dong, Seocho-gu, Seoul 137-040 (Korea, Republic of); Lim, Hyun Wook [Department of Radiology, Holy Family Hospital, College of Medicine, Catholic University of Korea, 2, Sosa-dong, Wonmi-gu, Pucheon, Kyung gi-do 420-717 (Korea, Republic of); Kim, Jin Ah [Department of Pathology, Holy Family Hospital, Catholic University of Korea, 2, Sosa-dong, Wonmi-gu, Pucheon-si, Kyung gi-do 420-717 (Korea, Republic of); Yoo, Won Jong [Department of Radiology, Holy Family Hospital, College of Medicine, Catholic University of Korea, 2, Sosa-dong, Wonmi-gu, Pucheon, Kyung gi-do 420-717 (Korea, Republic of)

    2007-05-15

    Objectives: To investigate the acute and repeated pulmonary damage in Sprague-Dawley rats caused by the inhalation of 3-methoxybutyl chloroformate (3-MBCF) using computed tomography (CT), and to correlate these results with those obtained from a pathological study. Methods: Sixty, 7-week-old rats were exposed to 3-MBCF vapor via inhalation (6 h/day) for 1 day (N = 20), 3 days (N = 20), and 28 days (5 days/week) (N = 20) using whole body exposure chambers at a concentration of 0 (control), 3, 6 and 12 ppm. CT examinations including densitometry and histopathologic studies were carried out. For the follow-up study, the rats exposed for 3 days were scanned using CT and their pathology was examined at 7, 14, and 28 days. Results: There was a significant decrease in the parenchymal density in the groups exposed to the 3-MBCF vapors for 1 day at 3 ppm (p = 0.022) or 6 ppm (p = 0.010), compared with the control. The parenchymal density of the rats exposed to12 ppm was significantly higher. The pathological findings in this period, the grades of vascular congestion, tracheobronchial exfoliation, and alveolar rupture were significant. In the groups exposed for 3 days, there was a large decrease in the parenchymal density with increasing dose (control: -675.48 {+-} 32.82 HU, 3 ppm: -720.65 {+-} 34.21 HU, 6 ppm: -756.41 {+-} 41.68 HU, 12 ppm: -812.56 {+-} 53.48 HU) (p = 0.000). There were significant density differences between each dose in the groups exposed for 28 days (p = 0.000). The CT findings include an irregular lung surface, areas of multifocal, wedge-shaped increased density, a heterogeneous lung density, bronchial dilatation, and axial peribronchovascular bundle thickening. The histopathology examination revealed the development of alveolar interstitial thickening and vasculitis, and an aggravation of the mainstem bronchial exudates and bronchial inflammation. The alveolar wall ruptures and bronchial dilatation became severe during this period. On the follow

  20. CORRELATION OF NEUROLOGIC DYSFUNCTION WITH CT-SCAN BRAIN FINDINGS AND CAROTID DOPPLER STUDY IN ACUTE ISCHAEMIC STROKE

    Directory of Open Access Journals (Sweden)

    Bharat L

    2014-12-01

    Full Text Available BACKGROUND AND OBJECTIVES: stroke is one of the most common debilitating diseases with a huge burden related to both mortality and morbidity, ischemic stroke is far common compared to haemorrhagic stroke and also associated with significant carotid stenosis. Hence this present study is carried out to evaluate all the aspects of this disease. OBJECTIVES: 1. To correlate the nature of lesion, site of lesion, and severity of lesion on clinical grounds with CT-Scan findings. 2. To find the prevalence of Carotid Artery Stenosis in Acute Ischaemic Stroke patients. 3. To find if there is any association between Carotid Artery Stenosis and risk factors such as Diabetes mellitus, Hypertension, Hyperlipidemia, Smoking and Age.

  1. Evaluation of the efficiency of FDG PET/CT in detection and characterization of skeletal metastases

    Directory of Open Access Journals (Sweden)

    Ahmed Wafaie

    2014-03-01

    Conclusion: Fused PET/CT was highly efficient in evaluation of skeletal metastases with superior performance in: detection of early bone marrow infiltration not apparent on CT, resolution of metabolic activity before definite signs of complete healing on CT, detection of missed sclerotic metastases on PET due to their relatively low metabolic activity, detection of intra and extra osseous recurrence and differentiation of benign from malignant bone lesions.

  2. Diagnosis of Chiari III malformation by second trimester fetal MRI with postnatal MRI and CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Alice B.; Glenn, Orit A. [University of California, San Francisco, Department of Radiology, San Francisco, CA (United States); Gupta, Nalin [University of California, San Francisco, Department of Neurosurgery, San Francisco, CA (United States); Otto, Carl [California Pacific Medical Center, Department of Perinatology, San Francisco, CA (United States)

    2007-10-15

    We report a case of Chiari III malformation diagnosed by fetal MRI. Ultrasound (US) performed at a gestational age of 18 weeks demonstrated a posterior skull base cyst. Repeat US at 19 weeks demonstrated neural tissue in the cyst, consistent with an encephalocele. MR imaging at 23 weeks confirmed the presence of an occipital encephalocele, demonstrated additional bony defect in the upper cervical spine, and identified abnormal morphology and position of the brainstem consistent with the diagnosis of Chiari III. Postnatal MRI and CT confirmed the fetal MRI findings and demonstrate the utility of fetal MRI in the early evaluation of songraphically detected posterior fossa abnormalities. (orig.)

  3. High-resolution CT in patients with chronic airflow obstruction: correlation with clinical diagnosis and pulmonary function test

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Ki Taek; Kang, Eun Young; Rhee, Ji Yong; Kim, Jin Hyung; Choi, Jung Ah; Cho, Jae Yoen; Oh, Yu Whan; Suh, Won Hyuck [College of Medicine, Korea University, Seoul (Korea, Republic of)

    2000-06-01

    To determine the utility of HRCT in the diagnosis of chronic airflow obstruction and to correlate the morphologic abnormalities revealed by this modality with functional impairment in patients with chronic airflow obstruction. This study involved 80 patients with chronic airflow obstruction who underwent HRCT and a pulmonary function test. Final clinical diagnosis in these patients was determined by a chest physician on the basis of clinical features, bronchoscopy, pulmonary function test, and HRCT. In order to diagnose and determine the extent of areas of decreased attenuation revealed by HRCT (the CT score), the findings of HRCT were retrospectively reviewed by two radiologists, who reached a consensus. Clinical and HRCT diagnoses were then compared, and the rate of agreement between them was calculated. The relationship between the extent of areas of decreased attenuation revealed by HRCT and by FEV1/FVC was evaluated using Correl's account and Student's unpaired t-test. The agreement rate between clinical and HRCT diagnoses was 77.5% (62/80). The rates for bronchiectasis (88.9%, 24/27), emphysema (93.9%, 31/33), and bronchiolitis obliterans (100%, 6/6) were considerably higher than those for chronic bronchitis and bronchial asthma. The correlation rate between CT score and FEV1/FVC was significant in bronchiectasis (p less than 0.05; r: -0.76) and bronchiolitis obliterans (p less than 0.01; r: -0.66), but not in cases involving emphysema, bronchial asthma, or chronic bronchitis (p greater than 0.05). HRCT is valuable in the diagnosis and prediction of physiologic impairment in patients with bronchiectasis and bronchiolitis obliterans, but has limited value in those with emphysema, chronic bronchitis or asthma. (author)

  4. Use of CT in the evaluation of cochlear otosclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Mafee, M.F.; Valvassori, G.E.; Deitch, R.L.; Norouzi, P.; Henrikson, G.C.; Capek, V.; Applebaum, E.L.

    1985-09-01

    Otosclerosis (otospongiosis) occurs when the hard endochondral bone of the otic capsule is replaced by spongy vascular foci of haversian bone. Using computed tomography (CT), the authors studied the ears of 32 selected patients with mixed or sensorineural hearing loss; 24 were suspected of having otosclerosis. CT proved valuable in detecting cochlear otosclerosis, foci of demineralization, and changes in bony texture and enables the easy recognition of subtle radiographic findings. This paper also reports the CT findings of temporal bones in osteogenesis imperfecta and Paget disease.

  5. Reliability of CT in preoperative evaluation of bladder carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nurmi, M.; Puntala, P. (Univ. of Turku (Finland). Dept. of Surgery); Katevuo, K. (Univ. of Turku (Finland). Dept. of Radiology)

    1988-01-01

    Sixty patients with bladder carcinoma were examined by CT prior to radical cystectomy. CT indicated perivesical tumor growth or extension to neighboring organs correctly in 60 % of the cases. Overstaging was observed in 23% and understaging in 8 % of the cases. Most of the difficulties concerned assessment of tumors in the anterior bladder wall and identification of the plane between the bladder and the seminal vesicle. In most instances CT provided no supplementary information to clinical staging, but was useful when obesity or previous irradiation impeded clinical staging. (authors).

  6. SU-C-17A-03: Evaluation of Deformable Image Registration Methods Between MRI and CT for Prostate Cancer Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Glide-Hurst, C; Zhong, H; Chin, K; Kumarasiri, A; Liu, C; Liu, M; Siddiqui, S [I Chetty, Henry Ford Health System, Detroit, MI (United States)

    2014-06-15

    Purpose: We evaluated the performance of two commercially available and one open source B-Spline deformable image registration (DIR) algorithms between T2-weighted MRI and treatment planning CT using the DICE indices. Methods: CT simulation (CT-SIM) and MR simulation (MR-SIM) for four prostate cancer patients were conducted on the same day using the same setup and immobilization devices. CT images (120 kVp, 500 mAs, voxel size = 1.1x1.1x3.0 mm3) were acquired using an open-bore CT scanner. T2-weighted Turbo Spine Echo (T2W-TSE) images (TE/TR/α = 80/4560 ms/90°, voxel size = 0.7×0.7×2.5 mm3) were scanned on a 1.0T high field open MR-SIM. Prostates, seminal vesicles, rectum and bladders were delineated on both T2W-TSE and CT images by the attending physician. T2W-TSE images were registered to CT images using three DIR algorithms, SmartAdapt (Varian), Velocity AI (Velocity) and Elastix (Klein et al 2010) and contours were propagated. DIR results were evaluated quantitatively or qualitatively by image comparison and calculating organ DICE indices. Results: Significant differences in the contours of prostate and seminal vesicles were observed between MR and CT. On average, volume changes of the propagated contours were 5%, 2%, 160% and 8% for the prostate, seminal vesicles, bladder and rectum respectively. Corresponding mean DICE indices were 0.7, 0.5, 0.8, and 0.7. The intraclass correlation coefficient (ICC) was 0.9 among three algorithms for the Dice indices. Conclusion: Three DIR algorithms for CT/MR registration yielded similar results for organ propagation. Due to the different soft tissue contrasts between MRI and CT, organ delineation of prostate and SVs varied significantly, thus efforts to develop other DIR evaluation metrics are warranted. Conflict of interest: Submitting institution has research agreements with Varian Medical System and Philips Healthcare.

  7. Using Abdominal CT Data for Visceral Fat Evaluation

    OpenAIRE

    2013-01-01

    Background: Quantitative assessment of body fat is important for the diagnosis and treatment of diseases related to obesity, Computed tomography (CT) becoming the standard procedure for measuring the abdominal fat distribution. Material and method: The retrospective study included 111 inpatients, who underwent routine abdominal CT exams in the Radiology Laboratory of SCJU Tg.Mures (2013). MPR MDCT (SOMATOM AS 64) data was processed using a custom written MATLAB R2009b software, ImageJ being u...

  8. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Kipritidis, John, E-mail: john.kipritidis@sydney.edu.au; Keall, Paul J. [Radiation Physics Laboratory, Sydney Medical School, University of Sydney, Sydney NSW 2006 (Australia); Siva, Shankar [Department of Radiation Oncology, Peter MacCallum Cancer Centre, and Sir Peter MacCallum Department of Oncology, University of Melbourne, Parkville VIC 3052 (Australia); Hofman, Michael S.; Callahan, Jason; Hicks, Rodney J. [Centre for Cancer Imaging, Peter MacCallum Cancer Centre and Department of Medicine, University of Melbourne, Melbourne VIC 3002 (Australia)

    2014-01-15

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant

  9. Nonlinear statistical reconstruction for flat-panel cone-beam CT with blur and correlated noise models

    Science.gov (United States)

    Tilley, Steven; Siewerdsen, Jeffrey H.; Zbijewski, Wojciech; Stayman, J. Webster

    2016-03-01

    Flat-panel cone-beam CT (FP-CBCT) is a promising imaging modality, partly due to its potential for high spatial resolution reconstructions in relatively compact scanners. Despite this potential, FP-CBCT can face difficulty resolving important fine scale structures (e.g, trabecular details in dedicated extremities scanners and microcalcifications in dedicated CBCT mammography). Model-based methods offer one opportunity to improve high-resolution performance without any hardware changes. Previous work, based on a linearized forward model, demonstrated improved performance when both system blur and spatial correlations characteristics of FP-CBCT systems are modeled. Unfortunately, the linearized model relies on a staged processing approach that complicates tuning parameter selection and can limit the finest achievable spatial resolution. In this work, we present an alternative scheme that leverages a full nonlinear forward model with both system blur and spatially correlated noise. A likelihood-based objective function is derived from this forward model and we derive an iterative optimization algorithm for its solution. The proposed approach is evaluated in simulation studies using a digital extremities phantom and resolution-noise trade-offs are quantitatively evaluated. The correlated nonlinear model outperformed both the uncorrelated nonlinear model and the staged linearized technique with up to a 86% reduction in variance at matched spatial resolution. Additionally, the nonlinear models could achieve finer spatial resolution (correlated: 0.10 mm, uncorrelated: 0.11 mm) than the linear correlated model (0.15 mm), and traditional FDK (0.40 mm). This suggests the proposed nonlinear approach may be an important tool in improving performance for high-resolution clinical applications.

  10. Correlation between semi-quantitative {sup 18}F-FDG PET/CT parameters and Ki-67 expression in small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, So Yeon; Lee, Eun Sub; Eo, Jae Seon [Dept. of Nuclear Medicine, Korea University Guro Hospital, Seoul (Korea, Republic of); Rhee, Seung Hong; Cho, Jae Hyuk; Choi, Sun Ju; Pahk, Kisso; Choe, Jae Gol; Kim, Sung Geun [Dept. of Nuclear Medicine, Korea University Anam Hospital, Seoul (Korea, Republic of); Lee, Si Nae [Dept. of Nuclear Medicine, G Sam Hospital, Gunpo (Korea, Republic of)

    2016-03-15

    The aim of this study was to evaluate the relationship between semiquantitative parameters on {sup 18}F-FDG PET/CT including maximum standardized uptake value (SUV{sub max}), mean standardized uptake value (SUV{sub mean}), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) and the expression level of Ki-67 in small-cell lung cancer (SCLC). Ninety-four consecutive patients with SCLC were enrolled in this study. They underwent {sup 18}F-FDG PET/CT for initial evaluation of SCLC, and we measured SUV{sub max}, {sub avg}SUV{sub mean}, MTV{sub sum}, and TLGtotal on {sup 18}F-FDG PET/CT images. The protein expression of Ki-67 was examined by immunohistochemical staining. Significant correlations were found between the MTVsum and Ki-67 labeling index (r=0.254, p=0.014) and the TLGtotal and Ki-67 labeling index (r=0.239, p=0.020). No correlation was found between the SUVmax and Ki-67 labeling index (r=0.116, p=0.264) and the {sub avg}SUV{sub mean} and Ki-67 labeling index (r=0.031, p=0.770). Dividing the Ki-67 expression level into three categories, it was suggested that increasing Ki-67 expression level caused a stepwise increase in the MTV{sub sum} and TLGtotal. (p=0.028 and 0.039, respectively), but not the SUV{sub max} and {sub avg}SUV{sub mean} (p=0.526 and 0.729, respectively). In conclusion, the volume-based parameters of {sup 18}F-FDG PET/CT correlate with immunohistochemical staining of Ki-67 in SCLC. Measurement of the MTV{sub sum} and TLGtotal by {sup 18}F-FDG PET/CT might be a simple, noninvasive, and useful method to determine the proliferative potential of cancer cells.

  11. Angular Correlation of the CMB in the R_h=ct Universe

    CERN Document Server

    Melia, Fulvio

    2012-01-01

    The emergence of several large-scale anomalies in the cosmic microwave background (CMB) has pointed to possible deficiencies in the standard model, or perhaps new physics driving the origin of density fluctuations in the early Universe and their evolution into the large-scale structure we see today. In this paper, we focus our attention on the observed absence of angular correlation of the CMB anisotropies at angles larger than ~60 degrees, and consider whether this feature may be understood in the context of the R_h=ct Universe. We find that the significant disparity between the predictions of LCDM and the WMAP sky (at a confidence level of greater than 99.9 percent) may be directly traced to inflation. The classic horizon problem does not exist in the R_h=ct Universe, so a period of exponential growth was not necessary in this cosmology in order to account for the general uniformity of the CMB (save for the aforementioned tiny fluctuations of 1 part in 100,000 in the WMAP relic signal). We show that the R_h...

  12. MULTIPLANAR MRI AND CT IMAGING OF SELLAR AND PARASELLAR TUMOURS WITH CLINICAL AND PATHOLOGICAL CORRELATION

    Directory of Open Access Journals (Sweden)

    Aswini Jyothi

    2016-03-01

    Full Text Available AIMS AND OBJECTIVES  To review the anatomy of sellar and parasellar regions.  To review a systematic anatomic approach to differential diagnosis of a sellar or parasellar tumors.  To correlate the diagnosis on magnetic resonance imaging with pathological DIAGNOSIS. MATERIALS AND METHODS A Prospective study of a total of 40 consecutive patients who were referred to the department of Radiodiagnosis, Osmania General Hospital from December 2010 and September 2012 were included in the study after informed consent. RESULTS Majority of patients were between 20 to 40 years. Male preponderance was seen (Males 26, females 14. Commonest tumor encountered in our study was pituitary adenoma (65% among which macro adenomas constituted about 50% of the cases and 15% of cases were micro adenomas. Most of the functioning adenomas were seen in females - of which prolactinoma was the commonest. CONCLUSION MR imaging is preferred over CT for the diagnosis of pituitary adenomas because it provides multiplanar high contrast images, higher definition of small sellar lesions (Microadenomas of the pituitary and further it improves anatomical definition of the pituitary, optic chiasma compression, cavernous sinus invasion before surgery. It is also preferred for postsurgical surveillance. CT has a complementary role in delineating bony destruction and the visualization of calcification and preoperative planning. Coronal images are the best for anatomical details of this region.

  13. Multimodal target correction by local bone registration: a PET/CT evaluation.

    Science.gov (United States)

    Oliveira-Santos, Thiago; Weitzel, Thilo; Klaeser, Bernd; Krause, Thomas; Nolte, Lutz-Peter; Weber, Stefan; Reyes, Mauricio

    2010-01-01

    PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.

  14. Bile duct complications of hepatic arterial infusion chemotherapy evaluated by helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Phongkitkarun, S. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)]. E-mail: rasih@mahidol.ac.th; Kobayashi, S. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Varavithya, V. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Huang, X. [Department of Biostatistics, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Curley, S.A. [Department of Surgical Oncology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Charnsangavej, C. [Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX (United States)

    2005-06-01

    AIM: To describe the imaging findings of bile duct complications of hepatic arterial infusion chemotherapy (HAIC) using helical CT, to set diagnostic criteria, to develop a CT grading system, and to correlate these with clinical findings and laboratory data. METHODS: Follow-up helical CT of the abdomen was performed every 3 months for 60 patients receiving HAIC. Three radiologists reviewed all CT studies before and after treatment, using either the picture archiving and communication system or hard copies. The findings of bile duct abnormalities were correlated with findings from other imaging techniques, clinical symptoms and laboratory data. RESULTS: Bile duct abnormalities developed in 34 (57%) of cases either during HAIC or 1 to 12 months after treatment. In 14 (41%) of these 34 patients, enhancement of the hepatic parenchyma along the dilated bile duct or in the segmental or lobar distribution was observed. In 43 cases (72%), normal or abnormal alkaline phosphatase levels were consistent with normal or abnormal CT findings, respectively. Increasing alkaline phosphatase and bilirubin levels were related to CT grade. CONCLUSION: Imaging findings of bile duct complications of HAIC are similar to those of primary sclerosing cholangitis, and correlate well with abnormal clinical and laboratory data. In the presence of such clinical abnormalities, thin-section helical CT with careful review of the imaging studies helps to determine the correct diagnosis, monitor the changes and guide appropriate treatment.

  15. Correlation of (18)F-FDG uptake on PET/CT with Ki67 immunohistochemistry in pre-treatment epithelial ovarian cancer.

    Science.gov (United States)

    Mayoral, M; Paredes, P; Saco, A; Fusté, P; Perlaza, P; Tapias, A; Fernandez-Martinez, A; Vidal, L; Ordi, J; Pavia, J; Martinez-Roman, S; Lomeña, F

    2017-08-28

    Standardized uptake value (SUV) and volumetric parameters such as metabolic tumour volume (MTV) and total lesion glycolysis (TLG) from (18)F-FDG PET/CT are useful criteria for disease prognosis in pre-operative and post-treatment epithelial ovarian cancer (EOC). Ki67 is another prognostic biomarker in EOC, associated with tumour aggressiveness. The aim of this study is to evaluate the association between (18)F-FDG PET/CT measurements and Ki67 in pre-treatment EOC to determine if PET/CT parameters could non-invasively predict tumour aggressiveness. A pre-treatment PET/CT was performed on 18 patients with suspected or newly diagnosed EOC. Maximum SUV (SUVmax), mean SUV (SUVmean), whole-body MTV (wbMTV), and whole-body TLG (wbTLG) with a threshold of 30% and 40% of the SUVmax were obtained. Furthermore, Ki67 index (mean and hotspot) was estimated in tumour tissue specimens. Immunohistochemical findings were correlated with PET parameters. The mean age was 57.0 years old (standard deviation 13.6 years). A moderate correlation was observed between mean Ki67 index and SUVmax (r=0.392), SUVmean 30% (r=0.437), and SUVmean 40% (r=0.443), and also between hotspot Ki67 index and SUVmax (r=0.360), SUVmean 30% (r=0.362) and SUVmean 40% (r=0.319). There was a weaker correlation, which was inversely negative, between mean and hotspot Ki67 and volumetric PET parameters. However, no statistical significant differences were found for any correlations. SUVmax and SUVmean were moderately correlated with Ki67 index, whereas volumetric PET parameters overall showed a weaker correlation. Thus, SUVmax and SUVmean could be used to assess tumour aggressiveness in pre-treatment EOC. Copyright © 2017 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  16. The Role of 18F-FDG PET/CT in the Evaluation of Gastric Cancer Recurrence

    Directory of Open Access Journals (Sweden)

    Hakan Cayvarlı

    2014-10-01

    Full Text Available Objective: F-18-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT has been widely used for staging, re-staging and for monitoring therapy-induced changes and response to therapy in patients with various types of cancer, but its utilization for gastric cancer has been limited. This study aimed to assess the diagnostic performance of 18F-FDG PET/CT for detecting recurrence in gastric cancer patients with radiologic or clinical suspicion of recurrence and its clinical impact on making decision. Methods: We performed a retrospective review of 130 consecutive patients who underwent PET/CT scans for post-treatment surveillance of gastric cancer between January 2008 and March 2012. The mean time between the initial diagnosis of gastric cancer and PET/CT studies was 44 weeks with a median of 18 weeks. The number and site of positive FDG uptake were analyzed and correlated with the final diagnosis by calculating the diagnostic values. We evaluated the diagnostic accuracy of PET/CT for detecting the recurrence in terms of whether or not histology had been SRC/musinous adenocarcinoma. The changes in the clinical management of patients were also evaluated according to the results of PET/CT. Results: Of all 130 patients, 91 patients were confirmed to have true recurrence. The sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of PET/CT for diagnosing true recurrence on a per-person basis were 91.2%, 61.5%, 84.6%, 75.0% and 82.3% respectively. Final diagnoses were confirmed histopathologically in 59 (45.4% of 130 patients and by clinical and radiological follow-up in the remaining 71 (54.6% patients. In the subgroup with SRC/mucinous adenocarcinoma differentiation of the primary tumor, there was no statistically significant difference in terms of diagnostic accuracy of PET/CT on a per-person basis. In addition, PET/CT results changed the patients’ management in 20 (15% cases

  17. Evaluation of pelvic ring injuries using SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Scheyerer, Max J. [University Hospital Zurich, Division of Trauma Surgery, Department of Surgery, Zurich (Switzerland); University Medical Center, Centre for Orthopaedic and Trauma Surgery, Cologne (Germany); Huellner, Martin; Pietsch, Carsten [University Hospital Zurich, Division of Nuclear Medicine, Department of Medical Radiology, Zurich (Switzerland); Werner, Clement M.L. [University Hospital Zurich, Division of Trauma Surgery, Department of Surgery, Zurich (Switzerland); Veit-Haibach, Patrick [University Hospital Zurich, Division of Nuclear Medicine, Department of Medical Radiology, Zurich (Switzerland); University Hospital Zurich, Diagnostic and Interventional Radiology, Department of Medical Radiology, Zurich (Switzerland)

    2014-08-12

    The incidence of pelvic fractures is relatively low compared with other fracture locations. The low incidence is in great contrast to the high morbidity and mortality. Particularly in the elderly, with apparently isolated fractures of the pubic rami, these observations are believed to be due to additional occult lesions of the posterior pelvic ring. In these cases diagnosis cannot be established by conventional imaging alone and SPECT/CT is considered as a diagnostic adjunct. The aim of this study was to assess concomitant bony or soft tissue lesions within the pelvic ring in a population of patients with fractures of the anterior elements. In all patients with no obvious lesions of the posterior pelvic ring on X-rays and CT or with suspicious but inconclusive findings on CT an additional SPECT/CT was carried out in a non-acute setting within 3 days of the trauma. In all cases additional lesions within the pelvic ring were found. Most lesions were vertical sacral fractures, followed by transverse fractures, one non-dislocated fracture of the acetabulum on the side of the pubic rami fracture, and one post-traumatic dilatation of the sacroiliac joint with increased tracer uptake. According to our results after SPECT/CT all patients with pubic rami fracture suffered additional lesions, none detectable previously by X-ray or CT, within the pelvic ring. In this context SPECT/CT has proved to be very helpful in the clinical routine to visualize occult fractures and instability within the sacroiliac joint. (orig.)

  18. The use of CT density changes at internal tissue interfaces to correlate internal organ motion with an external surrogate

    Energy Technology Data Exchange (ETDEWEB)

    Gaede, Stewart; Yu, Edward; Van Dyk, Jake; Battista, Jerry [Radiation Oncology Program, London Regional Cancer Program, London, Ontario (Canada); Carnes, Gregory; Lee, Ting-Yim [Department of Medical Biophysics, University of Western Ontario, London, Ontario (Canada)

    2009-01-21

    The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a cine mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing on multiple axial slices and measured the mean CT number versus respiratory phase. Tumour motion was directly correlated with external marker motion, acquired simultaneously, using the sample coefficient of determination, r{sup 2}. Only three of the ten patients showed correlation higher than r{sup 2} = 0.80 between tumour motion and external marker position. However, after taking into account time shifts (ranging between 0 s and 0.4 s) between the two data sets, all ten patients showed correlation better than r{sup 2} = 0.8. This non-invasive method for monitoring the motion of internal organs is an effective tool that can assess the use of external markers for 4D-CT imaging and respiratory-gated radiotherapy on a patient-specific basis.

  19. Correlation between Acute Coronary Syndrome Classification and Multi-detector CT Characterization of Plaque

    Institute of Scientific and Technical Information of China (English)

    Zhi-guo Wang; Lu-yue Gai; Jing-jing Gai; Ping Li; Xia Yang; Qin-hua Jin; Yun-dai Chen; Zhi-jun Sun; Zhi-wei Guan

    2011-01-01

    Objective To determine if multi-detector CT (MDCT) characterization of plaque is correlated with the classification of acute coronary syndrome (ACS). Methods Altogether 1900 patients were examined by MDCT from December 2007 to May 2009,of whom 95 patients fulfilled the criteria of ACS. Those patients were divided into the discrete plaque group (n=61) and diffuse plaque group (n=34) based on the findings in MDCT. The clinical diagnosis of ACS and CT results were analyzed, including segment stenosis score, segment involvement score, 3-vessel plaque score, left main score, calcification score, and remodeling index. The incidences of major adverse cardiac events in follow-up period were also recorded.Results The patients of the diffuse plaque group were older than those of the discrete plaque group (P<0.0001). The diffuse plaque group presented more cases of hypertension, peripheral artery disease, diabetes, and heart failure than discrete plaque group (all P<0.05). All the 5 patients with ST-segment elevation myocardial infarction were found in discrete plaque group. The segment stenosis score of the discrete plaque group was lower than that of the diffuse plaque group (5.15+3.55 vs. 14.91+5.37, P<0.001). The other four scores demonstrated significant inter-group difference as well (all P<0.05). The remodeling index of the discrete plaque group was higher (1.12+0.16 vs. 0.97+0.20, P<0.05). Follow-up data showed that major adverse cardiac events occurred more frequently in diffuse plaque group than in discrete group (29.41% vs.11.48%, P=0.0288).Conclusions Characteristics of discrete and diffuse plaques may be significandy different among different classes of ACS. The diffuse plaque may present higher risk, correlated to higher mortality. The diagnosis of discrete and diffuse plaques by MDCT would provide a new insight into the prognosis and treatment of ACS.

  20. Dimensions of the lumbar spinal canal: variations and correlations with somatometric parameters using CT

    Energy Technology Data Exchange (ETDEWEB)

    Karantanas, A.H. [Department of CT-MRI, Larissa General Hospital (Greece); Zibis, A.H.; Papaliaga, M.; Georgiou, E.; Rousogiannis, S. [Larissa Medical School, University of Thessaly, Larissa (Greece)

    1998-12-01

    The aim of this study was to investigate the correlation of vertebral dimensions with somatometric parameters in patients without clinical symptoms and radiological signs of central lumbar spinal stenosis. One hundred patients presenting with low back pain or sciatica were studied with CT. In each of the L3, L4 and L5 vertebra three slices were taken with the following measurements: 1. Slice through the intervertebral disc: (a) spinal canal area; (b) interarticular diameter; (c) interligamentous diameter. 2. Slice below the vertebral arcus: (a) dural sac area; (b) vertebral body area. 3. Pediculolaminar level: (a) anteroposterior diameter and interpedicular diameter of the spinal canal; (b) spinal canal area; (c) width of the lateral recesses. The Jones-Thomson index was also estimated. The results of the present study showed that there is a statistically significant correlation of height, weight and age with various vertebral indices. The conventional, widely accepted, anteroposterior diameter of 11.5 mm of the lumbar spinal canal is independent of somatometric parameters, and it is the only constant measurement for the estimation of lumbar spinal stenosis with a single value. The present study suggests that there are variations of the dimensions of the lumbar spinal canal and correlations with height, weight and age of the patient. (orig.) With 1 fig., 6 tabs., 24 refs.

  1. Synchrotron radiation μCT and histology evaluation of bone-to-implant contact

    DEFF Research Database (Denmark)

    Neldam, Camilla Albeck; Sporring, Jon; Rack, Alexander

    2017-01-01

    The purpose of this study was to evaluate bone-to-implant contact (BIC) in two-dimensional (2D) histology compared to high-resolution three-dimensional (3D) synchrotron radiation micro computed tomography (SR micro-CT). High spatial resolution, excellent signal-to-noise ratio, and contrast....... The histological evaluation showed a statistically significant difference between BIC in reconstructed and recipient bone (p .... Comparing histology and SR micro-CT evaluation a bias of 5.2% was found in reconstructed area, and 15.3% in recipient bone. We conclude that for evaluation of BIC with histology and SR micro-CT, SR micro-CT cannot be proven more precise than histology for evaluation of BIC, however, with this SR micro...

  2. CT in the evaluation of patients on ECMO due to acute respiratory failure

    Energy Technology Data Exchange (ETDEWEB)

    Lidegran, Marika; Jorulf, Haakan [Department of Paediatric Radiology, Astrid Lindgren Children' s Hospital, Karolinska Hospital, Karolinska Institute, 17176 Stockholm (Sweden); Palmer, Kenneth; Linden, Viveka [Department of ECMO, Astrid Lindgren Children' s Hospital, Karolinska Hospital, Karolinska Institute, Stockholm (Sweden)

    2002-08-01

    Heading AbstractBackground. In patients with acute severe respiratory failure (ARF) treated with extracorporeal membrane oxygenation (ECMO) the radiological evaluation has until now almost exclusively relied on bedside radiography and US. At St. Goeran/Karolinska ECMO centre CT has become a routine complement to bedside examinations.Objective. To review retrospectively the frequency, indications and findings on CT of patients with ARF on ECMO and to evaluate the risk of complications associated with transportation for CT examinations.Materials and methods. One hundred twelve neonates, children and adults were treated with ECMO from May 1994 to January 2001. Forty-six per cent of these patients had CT examinations on one or more occasions during ECMO, giving a total number of 238 examination sites on 104 occasions. All CT examinations were performed in the Paediatric Radiology Department and included a 10-min transport using a mobile ECMO system.Results. CT was more often performed in older patients and in patients with long ECMO runs. The main indications were suspected complications of ECMO and/or the underlying disease or a delay in clinical improvement. In 57% of the CT occasions, significant findings affecting treatment were revealed. There were no complications associated with the examinations or transport.Conclusions. CT is safe and useful in evaluation of patients with ARF during ECMO. (orig.)

  3. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    Directory of Open Access Journals (Sweden)

    Charikleia Triantopoulou

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts. The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm. This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation, the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins. Missed findings by imaging or pitfalls were recorded and we tried to explain all discrepancies between radiology evaluation and the histopathological findings. Radiologic-pathologic correlation is extremely important, adding crucial information on imaging limitations and enabling quality assessment of surgical specimens. The deep knowledge of different pancreatic tumors’ consistency and way of extension helps to improve radiologists’ diagnostic accuracy and minimize the radiological-surgical mismatching, preventing patients from unnecessary surgery.

  4. Cerebral artery evaluation of dual energy CT angiography with dual source CT

    Institute of Scientific and Technical Information of China (English)

    MA Rui; LIU Cheng; DENG Kai; SONG Shao-juan; WANG Dao-ping; HUANG Ling

    2010-01-01

    Background Conventional computed tomography angiography (CTA) is time consuming, user-dependent and has poor image quality in skull base region. This study assessed the feasibility of a new method, dual energy CTA for depicting the cerebral artery.Methods Phantom scan was done with head CTA sequences on dual source CT and 64 spiral CT for radiation dose calculation. Dual energy CTA was done with dual source CT on 36 patients who were suspected of having cerebral vascular disease. Three series axial images in 0.75 mm thick, 0.4 mm increment were acquired, which were named with 80 kV, 140 kV and merged images; 80 kV and 140 kV images were transferred into dual energy software, and maximum intensity projection (MIP) image was generated quickly by dual energy bone remove (DEBR group); merged images were transferred into In Space software to acquire MIP image through manual conventional bone remove (CoBR group). Post processing time and reading time were compared. Image qualities of the two groups were compared, mainly focusing on skull base segments of internal carotid artery and bone subtraction. ANOVA and SNK tests were applied for radiation dose comparison. Student's t test and Wilcoxon rank sum test were applied for assessing differences between data for significance. Cohen's kappa was used for interobserver agreement. Results Radiation dose of phantom scan showed dual energy CTA was between digital bone subtraction and conventional CTA. The post processing time and reading time were much shorter in DEBR than CoBR, and image quality in skull base was much higher in DEBR than CoBR (P0.5). Interobserver agreement for all vessel segments was excellent (kappa=0.97). Conclusions Dual energy CTA is a reliable, new modality for depicting cerebral artery, overcoming the limitation of conventional CTA in the skull base region. It can save much time in post processing and reading than conventional CTA.

  5. Correlation between abdominal perforator vessels identified with preoperative CT angiography and intraoperative fluorescent angiography in the microsurgical breast reconstruction patient.

    Science.gov (United States)

    Pestana, Ivo A; Zenn, Michael R

    2014-01-01

    CT angiography (CTA) has become a reliable method of perforator vessel identification. Indocyanine green fluorescent angiography (ICGLA) produces a real-time image of large- and small-caliber blood vessels. The aim of this prospective study was to compare ICGLA with CTA to evaluate its reliability of vessel identification and correlation to perforator vessel size and number determined preoperatively by CTA. The effect of both imaging techniques on flap design or intraoperative plan was also evaluated. Over a 1-year period, patients presenting for free-tissue transfer breast reconstruction underwent preoperative CTA mapping of abdominal perforators followed by intraoperative ICGLA. Using visualization software, scaling factors were calculated so CTA and ICGLA data could be compared. Eighteen patients (24 breast reconstructions) were included. Larger CTA perforator size was associated with larger actual size (P = 0.04). The largest CTA perforator or largest actual perforator was used 78% of the time. Increasing body mass index was not associated with larger CTA perforator size (P = 0.67) or more intense ICGLA blushes (P = 0.13). No significant correlation was found between CTA perforator location and ICGLA skin blush location, size, or intensity. CTA or SPY guided intraoperative procedure adjustments in 72% of patients. ICGLA identified poor soft-tissue perfusion and guided flap resection in 46% of patients. ICGLA skin blush location, size, and intensity do not correlate with CTA-identified perforating vessel location or actual perforating vessel size. Despite this, the ICGLA information was useful for evaluation of soft-tissue perfusion and flap design.

  6. Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis

    Science.gov (United States)

    Tyagi, Neelam; Fontenla, Sandra; Zhang, Jing; Cloutier, Michelle; Kadbi, Mo; Mechalakos, Jim; Zelefsky, Michael; Deasy, Joe; Hunt, Margie

    2017-04-01

    To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and a dual echo 3D mDIXON fast field echo (FFE) sequence for generating syn-CT. A dual-echo 3D FFE B 0 map was used for patient-induced susceptibility distortion analysis and a new 3D balanced-FFE sequence was evaluated for identification of implanted gold fiducial markers and subsequent image-guidance during radiotherapy delivery. Tissues were classified as air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned bulk HU values. The accuracy of syn-CT for treatment planning was analyzed by transferring the structures and plan from planning CT to syn-CT and recalculating the dose. Accuracy of localization at the treatment machine was evaluated by comparing registration of kV radiographs to either digitally reconstructed radiographs (DRRs) generated from syn-CT or traditional DRRs generated from the planning CT. Similarly, accuracy of setup using CBCT and syn-CT was compared to that using the planning CT. Finally, a MR-only simulation workflow was established and end-to-end testing was completed on five patients undergoing MR-only simulation. Dosimetric comparison between the original CT and syn-CT plans was within 0.5% on average for all structures. The de-novo optimized plans on the syn-CT met institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B 0 maps was within 1 mm and 0.5 mm in the body and prostate respectively. DRR and CBCT localization based on MR-localized fiducials showed a standard deviation of  <1 mm. End-to-end testing and MR simulation workflow was successfully validated. MRI derived synthetic CT can be successfully used for a MR

  7. Multi-Detector row CT urography on a 16-row CT scanner in the evaluation of urothelial tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, A.C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); University of Ioannina, Medical School, Ioannina (Greece); Efremidis, S.C.; Tsampoulas, C. [University Hospital of Ioannina, Department of Clinical Radiology, Ioannina (Greece); Kalef-Ezra, J. [University Hospital of Ioannina, Department of Medical Physics, Ioannina (Greece); Giannakis, D.; Sofikitis, N. [University Hospital of Ioannina, Department of Urology, Ioannina (Greece); Alamanos, Y. [University Hospital of Ioannina, Department of Hygiene and Public Health, Ioannina (Greece)

    2007-04-15

    The purpose of this study was to assess the role of multi-detector row CT urography (MDCTU), on a 16-row CT scanner in the evaluation of patients with painless hematuria, with emphasis placed in the detection of urothelial tumors. We retrospectively reviewed the MDCT urographies of 75 patients, referred for painless hematuria. The CT protocol included unenhanced images, obtained with a detector configuration of 16 x 1.5 mm and pitch of 1.2, nephrographic and excretory-phase images, obtained with a detector collimation of 16 x 0.75 mm and pitch of 1.2. Axial and coronal reformatted images were evaluated. Three-dimensional reformation of the excretory-phase images was performed using the volume-rendering technique. The standard of reference included clinical and imaging follow-up, cystoscopic, surgical and histologic findings. In 55 (73%) of 75 patients, the cause of hematuria was identified on MDCTU; the most common cause was urothelial cancer, including seven tumors with a diameter equal or smaller than 0.5 cm in diameter. Sixteen-row MDCTU provided satisfactory results in the investigation of patients with painless hematuria. The main advantage of the technique is its ability to detect uroepithelial malignancies. (orig.)

  8. Unenhanced multidetector CT (CT KUB) in the initial imaging of suspected acute renal colic: evaluating a new service

    Energy Technology Data Exchange (ETDEWEB)

    Chowdhury, F.U. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom); Kotwal, S. [Urology, Leeds Teaching Hospitals, Leeds (United Kingdom); Raghunathan, G.; Wah, T.M. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom); Joyce, A. [Urology, Leeds Teaching Hospitals, Leeds (United Kingdom); Irving, H.C. [Departments of Clinical Radiology, Leeds Teaching Hospitals, Leeds (United Kingdom)], E-mail: henry.irving@leedsth.nhs.uk

    2007-10-15

    Aim: To evaluate a new imaging pathway for the investigation of patients presenting with suspected acute renal colic. Materials and methods: A retrospective review of 500 consecutive cases of suspected acute renal colic was undertaken to evaluate the initial results of a new imaging pathway introduced at our institution, which completely replaced the intravenous urogram (IVU) with unenhanced multidetector CT (CT KUB). Results: The positive rate for urolithiasis was 44% (221/500), the negative rate 46% (229/500) and the rate of other significant findings was 12% (59/500). Female patients had a low positive rate compared with male patients (27.5 versus 57.5%; p < 0.001). Urological intervention was required in 28% (61/221) and these patients had a larger average stone size (6.6 versus 3.7 mm; p < 0.001) and the stone was located more proximally. Out-of-hours imaging was performed in 37% (186/500), and these patients had a higher positive rate (52 versus 40%; p < 0.001). Other findings included a wide range of acute non-urological conditions. Conclusion: The feasibility of replacing the acute IVU with CT KUB in the initial assessment of suspected acute renal colic was demonstrated in the present study. The technique enables rapid diagnosis of urolithiasis, stratification of patients likely to proceed to urological intervention, and prompt diagnosis of a variety of other acute pathological conditions.

  9. CT densitovolumetry in children with obliterative bronchiolitis: correlation with clinical scores and pulmonary function test results

    Directory of Open Access Journals (Sweden)

    Helena Mocelin

    2013-12-01

    Full Text Available OBJECTIVE: To determine whether air trapping (expressed as the percentage of air trapping relative to total lung volume [AT%] correlates with clinical and functional parameters in children with obliterative bronchiolitis (OB.METHODS: CT scans of 19 children with OB were post-processed for AT% quantification with the use of a fixed threshold of −950 HU (AT%950 and of thresholds selected with the aid of density masks (AT%DM. Patients were divided into three groups by AT% severity. We examined AT% correlations with oxygen saturation (SO2 at rest, six-minute walk distance (6MWD, minimum SO2 during the six-minute walk test (6MWT_SO2, FVC, FEV1, FEV1/FVC, and clinical parameters.RESULTS: The 6MWD was longer in the patients with larger normal lung volumes (r = 0.53. We found that AT%950 showed significant correlations (before and after the exclusion of outliers, respectively with the clinical score (r = 0.72; 0.80, FVC (r = 0.24; 0.59, FEV1 (r = −0.58; −0.67, and FEV1/FVC (r = −0.53; r = −0.62, as did AT%DM with the clinical score (r = 0.58; r = 0.63, SO2 at rest (r = −0.40; r = −0.61, 6MWT_SO2 (r = −0.24; r = −0.55, FVC (r = −0.44; r = −0.80, FEV1 (r = −0.65; r = −0.71, and FEV1/FVC (r = −0.41; r = −0.52.CONCLUSIONS: Our results show that AT% correlates significantly with clinical scores and pulmonary function test results in children with OB.

  10. Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qi; Li, Kewei; Xie, Peng [The First Affiliated Hospital, Chongqing Medical University, Department of Neurology, Chongqing (China); Lv, Fajin; Li, Yongmei; Luo, Tianyou [The First Affiliated Hospital, Chongqing Medical University, Department of Radiology, Chongqing (China)

    2009-09-15

    The purpose of our study was to compare the diagnostic performance of subtraction computed tomography angiography (CTA) with conventional nonsubtracted CTA and digital subtraction angiography (DSA) for the detection of intracranial aneurysms. A total of 76 patients underwent both subtraction CTA and conventional CTA for the detection and therapy planning of suspected intracranial aneurysms. Subtraction and conventional CTA images were independently assessed by two readers in a blinded manner. The possibility of endovascular treatment or surgical clipping was also assessed based on information provided by CT angiograms alone. In 64 patients, 75 aneurysms were present on DSA. On a per-aneurysm basis, the sensitivity of subtraction CTA was 98.6% for reader 1, and 100% for reader 2. However, sensitivity of conventional CTA was 94.6% for reader 1, and 93.3% for reader 2. Therapeutic decisions could be made regarding 63 patients based on information provided by subtraction CTA images. However, conventional CTA provided sufficient information to make this decision for 55 patients. Conventional CTA has limited sensitivity in detecting very small aneurysms as well as aneurysms adjacent to bone. Subtraction CTA performed on a 64-row multidetector CT is an accurate and promising diagnostic tool that seems to be equivalent to 2D DSA for the detection and pretreatment planning of intracranial aneurysms. (orig.)

  11. PET for the evaluation of pleural thickening observed on CT

    NARCIS (Netherlands)

    Kramer, H; Pieterman, RM; Slebos, DJ; Timens, W; Vaalburg, W; Koeter, GH; Groen, HJM

    2004-01-01

    Early discrimination between benign and malignant pleural diseases is vital for the treatment and prognosis of a patient. Imaging is traditionally performed with CT or MRI, with an accuracy of 50%-75%. PET has proven to be superior as a diagnostic tool in several malignancies. In this prospective st

  12. Amyloid goiter in a child - US, CT and MR evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Perez Fontan, F.J.; Mosquera Oses, J.; Pombo Felipe, F. (Hospital Juan Canalejo, La Coruna (Spain). Dept. of Radiology); Rodriguez Sanchez, I.; Arnaiz Pena, S. (Hospital Juan Canalejo, La Coruna (Spain). Dept. of Pediatric Oncology)

    1992-09-01

    There are few radiological descriptions of amyloid goiter, basically in adult patients or oriental origin. We present a ten-year-old boy with Still's disease and secondary thyroid amyloidosis, describing the US, CT and MR findings. (orig.).

  13. Usefulness evaluation of low-dose for emphysema: Compared with high-resolution CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jeong [Dept. of Radiological Technology, Daejeon Health Institute of Technology, Daejeon (Korea, Republic of)

    2016-09-15

    The purpose of this study was to evaluate the usefulness of low-dose CT (LDCT) for emphysema compared with high-resolution CT (HRCT). Measurements of radiation dose and noise were repeated 3 times in same exposure condition which was similar with obtaining HRCT and LDCT images. We analysed reading results of 146 subjects. Six images per participants selected for emphysema grading. Emphysema was graded for all 6 zones on the left and right sides of the lungs by the consensus reading of two chest radiologists using a 4-point scale. Between the HRCT and LDCT images, diagnostic differences and agreements for emphysema were analyzed by McNemar's and unweighted kappa tests, and radiation doses and noise by a Mann-Whitney U-test, using the SPSS 19.0 program. Radiation dose from HRCT was significantly higher than that of LDCT, but the noise was significantly lower in HRCT than in LDCT. Diagnostic agreement for emphysema between HRCT and LDCT images was excellent (k-value=0.88). Emphysema grading scores were not significantly different between HRCT and LDCT images for all six lung zones. Emphysema grading scores from LDCT images were significantly correlated with increased scores on HRCT images (r=0.599, p < 0.001). Considering the tradeoff between radiation dose and image noise, LDCT could be used as the gold standard method instead of HRCT for emphysema detection and grading.

  14. An evaluation on CT image acquisition method for medical VR applications

    Science.gov (United States)

    Jang, Seong-wook; Ko, Junho; Yoo, Yon-sik; Kim, Yoonsang

    2017-02-01

    Recent medical virtual reality (VR) applications to minimize re-operations are being studied for improvements in surgical efficiency and reduction of operation error. The CT image acquisition method considering three-dimensional (3D) modeling for medical VR applications is important, because the realistic model is required for the actual human organ. However, the research for medical VR applications has focused on 3D modeling techniques and utilized 3D models. In addition, research on a CT image acquisition method considering 3D modeling has never been reported. The conventional CT image acquisition method involves scanning a limited area of the lesion for the diagnosis of doctors once or twice. However, the medical VR application is required to acquire the CT image considering patients' various postures and a wider area than the lesion. A wider area than the lesion is required because of the necessary process of comparing bilateral sides for dyskinesia diagnosis of the shoulder, pelvis, and leg. Moreover, patients' various postures are required due to the different effects on the musculoskeletal system. Therefore, in this paper, we perform a comparative experiment on the acquired CT images considering image area (unilateral/bilateral) and patients' postures (neutral/abducted). CT images are acquired from 10 patients for the experiments, and the acquired CT images are evaluated based on the length per pixel and the morphological deviation. Finally, by comparing the experiment results, we evaluate the CT image acquisition method for medical VR applications.

  15. Classification of non-aneurysmal subarachnoid haemorrhage: CT correlation to the clinical outcome

    Energy Technology Data Exchange (ETDEWEB)

    Nayak, S., E-mail: sanjeevnayak@hotmail.co [Department of Neuroradiology, University Hospital of North Staffordshire, North Staffordshire Royal Infirmary, Princes Road, Stoke-on-Trent, Staffordshire, ST4 7LN (United Kingdom); Kunz, A.B.; Kieslinger, K. [University Clinic of Neurology, Paracelsus Medical University Salzburg (Austria); Ladurner, G.; Killer, M. [University Clinic of Neurology, Paracelsus Medical University Salzburg (Austria); Neuroscience Institute, Christian Doppler Clinic, Paracelsus Medical University Salzburg (Austria)

    2010-08-15

    Aim: To propose a new computed tomography (CT)-based classification system for non-aneurysmal subarachnoid haemorrhage (SAH), which predicts patients' discharge clinical outcome and helps to prioritize appropriate patient management. Methods and materials: A 5-year, retrospective, two-centre study was carried out involving 1486 patients presenting with SAH. One hundred and ninety patients with non-aneurysmal SAH were included in the study. Initial cranial CT findings at admission were correlated with the patients' discharge outcomes measured using the Modified Rankin Scale (MRS). A CT-based classification system (type 1-4) was devised based on the topography of the initial haemorrhage pattern. Results: Seventy-five percent of the patients had type 1 haemorrhage and all these patients had a good clinical outcome with a discharge MRS of {<=}1. Eight percent of the patients presented with type 2 haemorrhage, 62% of which were discharged with MRS of {<=}1 and 12% of patients had MRS 3 or 4. Type 3 haemorrhage was found in 10%, of which 16% had good clinical outcome, but 53% had moderate to severe disability (MRS 3 and 4) and 5% were discharged with severe disability (MRS 5). Six percent of patients presented with type 4 haemorrhage of which 42% of the patients had moderate to severe disability (MRS 3 and 4), 42% had severe disability and one-sixth of the patients died. Highly significant differences were found between type 1(1a and 1b) and type 2 (p = 0.003); type 2 and type 3 (p = 0.002); type 3 and type 4 (p = 0.001). Conclusion: Haemorrhages of the type 1 category are usually benign and do not warrant an extensive battery of clinical and radiological investigations. Type 2 haemorrhages have a varying prognosis and need to be investigated and managed along similar lines as that of an aneurysmal haemorrhage with emphasis towards radiological investigation. Type 3 and type 4 haemorrhages need to be extensively investigated to find an underlying cause.

  16. 异位胰腺的 CT 表现与病理联系%CT features of heterotopic pancreas and its correlation with pathologic changes

    Institute of Scientific and Technical Information of China (English)

    王倩; 杨学华; 高剑波; 梁盼; 魏一娟

    2014-01-01

    目的:分析异位胰腺的 CT 表现及其与病理的联系。方法回顾性分析19例经手术证实的异位胰腺的 CT 资料,其中14例行 CT 增强检查,分析 CT 表现的特征。结果19例异位胰腺均为单发病灶,直径0.8~4.7 cm,平均(2.2±0.6)cm。CT 平扫示病灶密度较均匀,其中位于胃部7例,十二指肠8例,空肠2例,回肠1例,贲门淋巴结旁1例。5例病灶边界模糊,周围呈渗出性改变,类似急性胰腺炎,2例显示中央脐凹征。病理证实异位于黏膜下14例,肌层3例,浆膜1例,1例位于腹腔内。动态增强扫描9例早期呈明显强化,类似胰腺强化和强化后的衰减,病理组成以胰腺腺泡组织为主,4例强化程度低于正常胰腺,病理以胰腺导管及少量胰腺腺泡组成,1例强化不明显,CT 表现类似平滑肌瘤,病理以胰腺导管及增生平滑肌为主。结论异位胰腺多呈黏膜下病变特征,不同的强化方式与其病理组成密切相关。%Objective To analyze the CT findings of heterotopic pancreas and the correlation with pathologic changes.Methods CT findings in 1 9 patients with heterotopic pancreas proven by surgery were reviewed retrospectively,14 of whom were scanned with enhanced CT.The correlation of CT findings and pathologic results were also analyzed.Results All patients had a single lesion with sized range from 0.8 to 4.7 cm and mean diameter of (2.2±0.6)cm.All lesions with homogeneous density were showed on plain scans including 7 lesions in stomach,8 in duodenum,2 in jejunum,1 in ileum and 1 beside the cardiac lymph nodes.The border of the lesions in 5 was unclear with exudative changes,mimicking acute pancreatitis.A sign of central umbilical concave was found in 2.Pathological results confirmed 14 lesions in submucosa,3 in muscular layer,1 in serosal layer and 1 in abdominal cavity.Hetero-topic pancreas presented early obvious enhancement in 9,mimicking normal pancreas,which was composed chiefly of pancreatic aci

  17. Functional testicular evaluation using PET/CT with {sup 18}F-fluorodeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Dierickx, Lawrence Oliver; Zerdoud, Slimane; Filleron, Thomas; Brillouet, Severine [Institut Claudius Regaud, Service of Nuclear Medicine, Toulouse (France); Huyghe, Eric; Delauney, Boris; Bujan, Louis; Plante, Pierre [CHU Toulouse, Toulouse (France); Nogueira, Daniela; Montagut, Jacques [I.F.R.E.A.R.E.S., Toulouse (France); Courbon, Frederic [Institut Claudius Regaud, Service of Nuclear Medicine, Toulouse (France); CHU Toulouse, Toulouse (France)

    2012-01-15

    PET/CT using {sup 18}F-FDG is a well-established diagnostic examination in oncology, cardiology and neurology. The clinical significance of nontumoral testicular uptake of FDG is unknown. Functional testicular imaging may have important clinical applications in the diagnosis and prognosis of male infertility. The aim of this study was to determine the andrological value of a FDG PET/CT in analysing testicular function, by correlating the PET/CT data with the sperm parameters. Retrospective analysis of FDG PET/CT in 20 consecutive cancer patients without testicular pathology in whom two semen samples had been obtained for analysis before any chemotherapy. FDG PET/CT parameters were the mean standardized uptake value (SUVmean), used for measuring the intensity of uptake, and the functional testicular volume (FV). For statistical analysis, a Spearman's rank correlation test and a Mann-Whitney test were used. Of 20 patients (mean age 22 years), 18 had provided two sperm samples for cryopreservation. Sperm concentration was above 20 x 10{sup 6}/ml in 55% of the patients. The intensity of uptake and the FV were correlated with the total sperm count, the sperm concentration and motility (p < 0.05). The difference in SUVmean between the two testes showed an inverse correlation with sperm concentration (p = 0.036). Normospermic and oligospermic men had significant differences in: (1) mean SUVmean, (2) mean FV, and (3) the difference in intensity of uptake between the testes (p < 0.05). This is the first report on the andrological value of FDG PET/CT in analysing nontumoral testicular function. This pilot study showed a significant correlation between intensity of uptake of FDG and testicular FV with the main sperm parameters. PET/CT with FDG could become a useful new tool in assisted reproductive technologies and other andrological or urological applications. (orig.)

  18. Evaluation of CT after combined injection method by intra and para-variceal injection

    Energy Technology Data Exchange (ETDEWEB)

    Urita, Yoshihisa; Ishihara, Manabu; Ozaki, Motonobu; Hachiya, Akihiko; Yamada, Shuuichi; Mutoh, Masue; Nakata, Masayuki; Ohtsuka, Sachio; Machida, Keiichi (Toho Univ., Tokyo (Japan). School of Medicine)

    1992-07-01

    The purpose of this study is to clarify the distribution of sclerosant injected into the paravariceal esophageal wall. CT scan of the chest was performed 30 minutes after combined injection sclerotherapy (EIS) using 1% Polidocanol (Aethoxysklerol: AS) in 23 patients with esophageal varices. CT findings included (1) ring-enhanced esophageal wall (2) ring-enhanced paraesophageal wall (3) locally enhanced esophageal wall (4) beltlike-enhanced parietal pleura. Types (1) (2) (4) were obtained in the 1st or the 2nd EIS, and type (3) was obtained in the 3rd EIS or more. These CT findings did not correlate with total volume of injected sclerosant. Seven of 8 patients with CT finding of Type (3) had esophageal ulcer. (We consider that esophageal ulcer is necessary to fibrosis of the lower eshophageal wall). When CT finding of type (3) was obtained, we put off the next procedure of EIS. Pleural effusion occured after 2 of 18 procedures with CT finding of type (1), 2 of 9 with type (2), 0 of 8 with type (3), and 1 of 14 with type (4). We speculated that most of patients with type (4) would have pleural effusion. But CT findings did not correlate with pleural effusion. Chest pain occurred after 1 of 18 procedures with CT finding of type (1), 1 of 9 with type (2), 2 of 8 with type (3), and 1 of 14 with type (4). Fever occurred after 0 of 18 procedures with CT findings of type (1), 0 of 9 with type (2), 2 of 8 with type (3), 0 of 14 with type (4). These results suggest that 1% AS injected into paravariceal esophageal wall have no reference to the minor complications. The sclerosants injected into the paravaries was thought to diffuse rapidly, but it is unlikely that this distribution of 1% AS is the main factor of pleural effusion, chest pain, and fever after EIS. (author).

  19. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    DEFF Research Database (Denmark)

    Madsen, Poul Henning; Holdgaard, Paw Christian; Buck Christensen, Janne

    2016-01-01

    PURPOSE: Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. METHODS: To review the clinical usefulness of this imaging modality in the diagnosis, staging...... the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). RESULTS: We found the following important...... results from the literature review: 1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). 2) PET-CT reduces the number of futile treatment trials (recommendation level A). 3) The sensitivity of PET-CT in general is insufficient to rule out...

  20. Evaluation of the reconstruction of image acquired from CT simulator to reduce metal artifact

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ji Hun; Park, Jin Hong; Choi, Byung Don; Won, Hui Su; Chang, Nam Jun; Goo, Jang Hyun; Hong, Joo Wan [Dept. of Radiation Oncology, Seoul national university bundang hospital, Sungnam (Korea, Republic of)

    2014-12-15

    This study presents the usefulness assessment of metal artifact reduction for orthopedic implants(O-MAR) to decrease metal artifacts from materials with high density when acquired CT images. By CT simulator, original CT images were acquired from Gammex and Rando phantom and those phantoms inserted with high density materials were scanned for other CT images with metal artifacts and then O-MAR was applied to those images, respectively. To evaluate CT images using Gammex phantom, 5 regions of interest(ROIs) were placed at 5 organs and 3 ROIs were set up at points affected by artifacts. The averages of standard deviation(SD) and CT numbers were compared with a plan using original image. For assessment of variations in dose of tissue around materials with high density, the volume of a cylindrical shape was designed at 3 places in images acquired from Rando phantom by Eclipse. With 6 MV, 7-fields, 15x15cm{sup 2} and 100 cGy per fraction, treatment planning was created and the mean dose were compared with a plan using original image. In the test with the Gammex phantom, CT numbers had a few difference at established points and especially 3 points affected by artifacts had most of the same figures. In the case of O-MAR image, the more reduction in SD appeared at all of 8 points than non O-MAR image. In the test using the Rando Phantom, the variations in dose of tissue around high density materials had a few difference between original CT image and CT image with O-MAR. The CT images using O-MAR were acquired clearly at the boundary of tissue around high density materials and applying O-MAR was useful for correcting CT numbers.

  1. Correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size

    Directory of Open Access Journals (Sweden)

    Chenshi ZHANG

    2008-02-01

    Full Text Available Background and Objective The solitary pulmonary nodules (SPNs is one of the most common findings on chest radiographs. It becomes possible to provide more accurately quantitative information about blood flow patterns of solitary pulmonary nodules (SPNs with multi-slice spiral computed tomography (MSCT. The aim of this study is to evaluate the correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size. Methods 68 patients with maliagnant solitary pulmonary nodules (SPNs (diameter <=4 cmunderwent multi-location dynamic contrast material-enhanced (nonionic contrast material was administrated via the antecubital vein at a rate of 4mL/s by an autoinjector, 4*5mm or 4*2.5mm scanning mode with stable table were performed. serial CT. Precontrast and postcontrast attenuation on every scan was recorded. Perfusion (PSPN, peak height (PHSPNratio of peak height of the SPN to that of the aorta (SPN-to-A ratioand mean transit time(MTT were calculated. The correlation between the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules and tumor size were assessed by means of linear regression analysis. Results No significant correlations were found between the tumor size and each of the peak height (PHSPN ratio of peak height of the SPN to that of the aorta (SPN-to-A ratio perfusion(PSPNand mean transit time (r=0.18, P=0.14; r=0.20,P=0.09; r=0.01, P=0.95; r=0.01, P=0.93. Conclusion No significant correlation is found between the tumor size and each of the quantifiable parameters of blood flow pattern derived with dynamic CT in maliagnant solitary pulmonary nodules.

  2. Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population

    Directory of Open Access Journals (Sweden)

    Mahmoud Jabalameli

    2016-04-01

    Full Text Available Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational alignment in preoperative CT scans of Iranian patients who were candidates for total knee arthroplasty and the effects of age, gender, and knee alignment on these relationships. Methods: One hundred and eight cases who were admitted to two university hospitals for total knee arthroplasty were included in this study. The rotation of the distal femur was evaluated using single axial CT images through the femoral epicondyle. Four lines were drawn digitally in this view: anatomical and surgical transepicondylar axes, posterior condylar axis and the Whiteside anteroposterior line. The alignment of the extremity was evaluated in the standing alignment view. Then the angles were measured along these lines and their relationship was evaluated. Results: The mean angle between the anatomical transepicondylar axis and posterior condylar axis and between the surgical transepicondylar axis and posterior condylar axis were 5.9 ± 1.6 degrees and 1.6±1.7 degrees respectively. The mean angle between the Whiteside’s anteroposterior line and the line perpendicular to the posterior condylar axis was 3.7±2.1 degrees. Significant differences existed between the two genders in these relationships. No significant correlation between the age of patients and angles of the distal femur was detected. The anatomical surgical transepicondylar axis was in 4.3 degrees external rotation in relation to the surgical transepicondylar axis. Conclusion: Preoperative CT scanning can help accurately determine rotational landmarks of the distal femur. If one of the reference axes cannot be

  3. CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation.

    Science.gov (United States)

    Foldyna, Borek; Jungert, Camelia; Luecke, Christian; von Aspern, Konstantin; Boehmer-Lasthaus, Sonja; Rueth, Eva Maria; Grothoff, Matthias; Nitzsche, Stefan; Gutberlet, Matthias; Mohr, Friedrich Wilhelm; Lehmkuhl, Lukas

    2015-08-01

    To compare the performance of semi-automatic versus manual segmentation for ECG-triggered cardiovascular computed tomography (CT) examinations prior to transcatheter aortic valve replacement (TAVR), with focus on the speed and precision of experienced versus inexperienced observers. The preoperative ECG-triggered CT data of 30 consecutive patients who were scheduled for TAVR were included. All datasets were separately evaluated by two radiologists with 1 and 5 years of experience (novice and expert, respectively) in cardiovascular CT using an evaluation software program with or without a semi-automatic TAVR workflow. The time expended for data loading and all segmentation steps required for the implantation planning were assessed. Inter-software as well as inter-observer reliability analysis was performed. The CT datasets were successfully evaluated, with mean duration between 520.4 ± 117.6 s and 693.2 ± 159.5 s. The three most time-consuming steps were the 3D volume rendering, the measurement of aorta diameter and the sizing of the aortic annulus. Using semi-automatic segmentation, a novice could evaluate CT data approximately 12.3% faster than with manual segmentation, and an expert could evaluate CT data approximately 10.3% faster [mean differences of 85.4 ± 83.8 s (p segmentation, with comparable exactness, showing a benefit for experienced and inexperienced observers.

  4. Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer.

    Science.gov (United States)

    Wang, Hesheng; Chandarana, Hersh; Block, Kai Tobias; Vahle, Thomas; Fenchel, Matthias; Das, Indra J

    2017-06-26

    Interest in MR-only treatment planning for radiation therapy is growing rapidly with the emergence of integrated MRI/linear accelerator technology. The purpose of this study was to evaluate the feasibility of using synthetic CT images generated from conventional Dixon-based MRI scans for radiation treatment planning of lung cancer. Eleven patients who underwent whole-body PET/MR imaging following a PET/CT exam were randomly selected from an ongoing prospective IRB-approved study. Attenuation maps derived from the Dixon MR Images and atlas-based method was used to create CT data (synCT). Treatment planning for radiation treatment of lung cancer was optimized on the synCT and subsequently copied to the registered CT (planCT) for dose calculation. Planning target volumes (PTVs) with three sizes and four different locations in the lung were planned for irradiation. The dose-volume metrics comparison and 3D gamma analysis were performed to assess agreement between the synCT and CT calculated dose distributions. Mean differences between PTV doses on synCT and CT across all the plans were -0.1% ± 0.4%, 0.1% ± 0.5%, and 0.4% ± 0.5% for D95, D98 and D100, respectively. Difference in dose between the two datasets for organs at risk (OARs) had average differences of -0.14 ± 0.07 Gy, 0.0% ± 0.1%, and -0.1% ± 0.2% for maximum spinal cord, lung V20, and heart V40 respectively. In patient groups based on tumor size and location, no significant differences were observed in the PTV and OARs dose-volume metrics (p > 0.05), except for the maximum spinal-cord dose when the target volumes were located at the lung apex (p = 0.001). Gamma analysis revealed a pass rate of 99.3% ± 1.1% for 2%/2 mm (dose difference/distance to agreement) acceptance criteria in every plan. The synCT generated from Dixon-based MRI allows for dose calculation of comparable accuracy to the standard CT for lung cancer treatment planning. The dosimetric agreement

  5. CT-based manual segmentation and evaluation of paranasal sinuses.

    Science.gov (United States)

    Pirner, S; Tingelhoff, K; Wagner, I; Westphal, R; Rilk, M; Wahl, F M; Bootz, F; Eichhorn, Klaus W G

    2009-04-01

    Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set. Three different colors for segmentation represent diverse risk areas. Extension and volumetric measurements were performed. Three-dimensional reconstruction was generated after segmentation. Manual segmentation took 8-10 h for each CT dataset. The mean volumes were: right maxillary sinus 17.4 cm(3), left side 17.9 cm(3), right frontal sinus 4.2 cm(3), left side 4.0 cm(3), total frontal sinuses 7.9 cm(3), sphenoid sinus right side 5.3 cm(3), left side 5.5 cm(3), total sphenoid sinus volume 11.2 cm(3). Our manually segmented 3D-models present the patient's individual anatomy with a special focus on structures in danger according to the diverse colored risk areas. For safe robot assistance, the high-accuracy models represent an average of the population for anatomical variations, extension and volumetric measurements. They can be used as a database for automatic model-based segmentation. None of the segmentation methods so far described provide risk segmentation. The robot's maximum distance to the segmented border can be adjusted according to the differently colored areas.

  6. Gated cardiac imaging using a continuously rotating CT scanner: clinical evaluation of 91 patients.

    Science.gov (United States)

    Oyama, Y; Uji, T; Hirayama, T; Inada, Y; Ishikawa, T; Fujii, M

    1984-05-01

    To produce electrocardiographically (ECG)-gated computed tomographic (CT) images of the heart, a post-data-acquisition ECG correlation technique was used in which data for missing angular projections are derived from the original scan data to complete 360 angular projections. Improved image quality and clinical usefulness were demonstrated compared with routine nongated CT and two-dimensional echocardiography. Gated CT was better than nongated CT in 26 of 41 positive and three of five negative cases of suspected myocardial infarction, four of 10 positive and one of 12 negative cases of suspected left atrial mass, three of 10 cases with pericardial fluid collection, and three other cases. Compared with echocardiography, CT was of additional value in eight of 10 cases of myocardial infarction, five of nine positive and one of 10 negative cases of suspected left atrial mass, four of 10 positive and one of three negative cases of suspected pericardial fluid collection, and two other cases. The equipment required for CT gating is of low cost, but the examination time is lengthy and less conveniently performed than echocardiography. However, when echocardiography is indecisive or suspected to be falsely negative, gated CT imaging of the heart is recommended.

  7. Application of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation

    Institute of Scientific and Technical Information of China (English)

    Yong-Shu Gao; Xing-Can Ma

    2015-01-01

    Objective:To explore the feasibility and effectiveness of 64 slice spiral CT in evaluating the patency of coronary artery after stent implantation.Methods:The 64 slice spiral CT image data of 125 patients after coronary artery stent implantation were collected, meanwhile, the image data of 25 patients underwent coronary angiography were also collected. The feasibility and accuracy of 64 slice spiral CT coronary artery stent imaging were comparatively analyzed. Results: The 64 slice spiral CT imaging quality with a stent diameter greater than 3.00 mm was significantly superior to that with a diameter of 2.25-3.00 mm. The CT imaging quality in the left main coronary artery and anterior descending artery was significantly higher than that in the left circumflex coronary artery. The CT imaging quality in the left main coronary artery was significantly higher than that in the right coronary artery. The CT reconstruction imaging quality in the drug coating stent was significantly superior to that in the bare metal stent. The sensitivity of 64 slice spiral CT was 100.00%, and the accuracy was 100.00%. In detecting the coronary artery with occlusion and stenosis (stent stenosis greater than 50%), the sensitivity was 90.00%, the false negative rate was 10.00%, and the positive predicative value was 100.00%.Conclusions:The effect of 64 slice spiral CT coronary imaging in evaluating the patency of coronary artery after stent implantation is highly consistent with that by coronary angiography, with a simple operation, less risk, and low cost, and thus, it can be completely taken as the imaging method in evaluating the patency of coronary artery after stent implantation.

  8. Cervical spine evaluation in urban trauma centers: lowering institutional costs and complications through helical CT scan.

    Science.gov (United States)

    Grogan, Eric L; Morris, John A; Dittus, Robert S; Moore, Derek E; Poulose, Benjamin K; Diaz, Jose J; Speroff, Theodore

    2005-02-01

    In the evaluation of the cervical spine (c-spine), helical CT scan has higher sensitivity and specificity than plain radiographs in the moderate- and high-risk trauma population, but is more costly. We hypothesize that institutional costs associated with missed injuries make helical CT scan the least costly approach. A cost-minimization study was performed using decision analysis examining helical CT scan versus radiographic evaluation of the c-spine. Parameter estimates were obtained from the literature for probability of c-spine injury, probability of paralysis after missed injury, plain film sensitivity and specificity, CT scan sensitivity and specificity, and settlement cost of missed injuries resulting in paralysis. Institutional costs of CT scan and plain radiography were used. Sensitivity analyses tested robustness of strategy preference, accounted for parameter variability, and determined threshold values for individual parameters on strategy preference. C-spine evaluation with helical CT scan has an expected cost of US 554 dollars per patient compared with US 2,142 dollars for plain films. CT scan is the least costly alternative if threshold values exceed US 58,180 dollars for institutional settlement costs, 0.9% for probability of c-spine fracture, and 1.7% for probability of paralysis. Plain films are least costly if CT scan costs surpass US 1,918 dollars or plain film sensitivity exceeds 90%. Helical CT scan is the preferred initial screening test for detection of cervical spine fractures among moderate- to high-risk patients seen in urban trauma centers, reducing the incidence of paralysis resulting from false-negative imaging studies and institutional costs, when settlement costs are taken into account.

  9. Prospective evaluation of the radiologist's hand dose in CT-guided interventions; Prospektive Evaluation der Handdosis des Radiologen im Rahmen von CT-gestuetzten Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Rogits, B.; Jungnickel, K.; Loewenthal, D.; Dudeck, O.; Pech, M.; Ricke, J. [Magdeburg Univ. (Germany). Radiology and Nuclear Medicine; Kropf, S. [Magdeburg Univ. (Germany). Dept. of Biometry and Medical Informatics; Nekolla, E.A. [The Federal Office for Radiation Protection, Neuherberg (Germany). Dept. of Radiation Protection and Health; Wieners, G. [Charite CVC, Berlin (Germany). Dept. of Radiology

    2013-11-15

    Purpose: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. Materials and Methods: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. Results: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. Conclusion: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions. (orig.)

  10. Obscure gastrointestinal bleeding: evaluation with 64-section multiphase CT enterography--initial experience.

    Science.gov (United States)

    Huprich, James E; Fletcher, Joel G; Alexander, Jeffrey A; Fidler, Jeff L; Burton, Sharon S; McCullough, Cynthia H

    2008-02-01

    This retrospective HIPAA-compliant study was approved by the institutional review board and institutional conflict of interest committee. Patients gave informed consent for use of medical records. The purpose of the study was to retrospectively evaluate the findings depicted at computed tomographic (CT) enterography performed with a 64-section CT system and by using neutral enteric contrast material and a three-phase acquisition in patients with obscure gastrointestinal bleeding (OGIB). Twenty-two outpatients (11 men, 11 women; age range, 37-83 years) with OGIB underwent CT enterography. Findings were compared with capsule and traditional endoscopic, surgical, and angiographic findings. CT enterographic findings were positive for a bleeding source in 10 (45%) of 22 patients. Eight of 10 positive findings at CT enterography were also positive at capsule endoscopy or subsequent clinical diagnosis. CT enterography helped correctly identify three lesions undetected at capsule endoscopy. Study results suggest that multiphase, multiplanar CT enterography may have a role in the evaluation of OGIB.

  11. Association between CT-evaluated lumbar lordosis and features of spinal degeneration, evaluated in supine position

    Science.gov (United States)

    Kalichman, Leonid; Li, Ling; Hunter, David; Been, Ella

    2013-01-01

    Background Context Few studies have directly evaluated the association of lumbar lordosis and segmental wedging of the vertebral bodies and intervertebral disks with prevalence of spinal degenerative features. Purpose To evaluate the association of CT-evaluated lumbar lordosis, segmental wedging of the vertebral bodies and that of the intervertebral disks with various spinal degeneration features. Study design This cross-sectional study was a nested project to the Framingham Heart Study. Sample A random consecutive subset of 191 participants chosen from the 3590 participants enrolled in the Framingham Heart Study who underwent multi-detector CT to assess aortic calcification. Outcome Measures Physiologic Measures Dichotomous variables indicating the presence of intervertebral disc narrowing, facet joint osteoarthritis, spondylolysis, spondylolisthesis and spinal stenosis and density (in Hounsfield units) of multifidus and erector spinae muscles were evaluated on supine CT, as well as the lordosis angle (LA) and the wedging of the vertebral bodies and intervertebral disks. Sum of vertebral bodies wedging (ΣB) and sum of intervertebral discs wedging (ΣD) were used in analyses. Methods Mean values (±SD) of LA, ΣB and ΣD were calculated in males and females and compared using the t-test. Mean values (±SD) of LA, ΣB and ΣD in 4 age groups: 0.05) with increasing age. LA showed statistically significant association with presence of spondylolysis (OR(95%CI): 1.08(1.02–1.14)) and with density of multifidus (1.06 (1.01–1.11). as well as a marginally significant association with isthmic spondylolisthesis (1.07(1.00–1.14). ΣB showed a positive association with degenerative spondylolisthesis and disc narrowing ((1.14(1.06–1.23) and 1.04 (1.00–1.08), correspondingly), whereas ΣD showed negative one (0.93(0.87–0.98) and (0.93(0.89–0.97), correspondingly). Conclusions Significant associations were found between lumbar lordosis evaluated in supine position

  12. CT evaluation of underlying cause in spontaneous subcapsular and perirenal hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Sebastia, M.C. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Perez-Molina, M.O. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Alvarez-Castells, A. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Quiroga, S. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain); Pallisa, E. [Department of Radiology, IDI, Hospital General Universitari Vall d`Hebron, E-08 305 Barcelona (Spain)

    1997-06-01

    We evaluated the CT scans of 13 patients with spontaneous subcapsular or perinephric hemorrhage (SPH) associated with these underlying causes: 4 angiomyolipomas, 2 renal cell carcinomas, 1 renal metastatic malignant melanoma, 1 ruptured renal artery aneurysm, 1 adrenal myelolipoma, 1 ruptured renal abscess, 2 ruptured hemorrhagic cysts, and 1 patient with undiagnosed coagulation disorder. Our objective was to ascertain whether an underlying cause of SPH was identifiable by CT, and to determine the extension of the hematomas. Computed tomography identified the hematoma in all 13 cases (sensitivity 100 %). In all 12 cases in which there was a renal or adrenal anatomic lesion, the underlying cause was identified with CT (100 %), with correct diagnosis in 11 cases (91.6 %). The case in which no lesion was identified was the undiagnosed coagulation disorder. We conclude that CT is a useful technique for the initial evaluation of SPH, permitting diagnosis of hemorrhage and identification of the underlying cause. (orig.). With 6 figs., 1 tab.

  13. Extensive Invasive Extramammary Paget Disease Evaluated by F-18 FDG PET/CT

    OpenAIRE

    Li, Zu-Gui; Qin, Xiao-Jing

    2015-01-01

    Abstract Extramammary Paget disease (EMPD) is a rare cutaneous, intraepithelial adenocarcinoma. Because of its rarity, little is known about the value of fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in evaluating this disease. Our case report aims to increase current knowledge of FDG PET/CT in EMPD as a noninvasive imaging tool for assessing the extension of the disease and detecting distant metastases. We reported a 64-year-old Chinese man who presented ...

  14. Evaluation of thin section CT scanning in the prone position of metastatic axillary lymphnodes for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hata, Yasuhiro; Ogawa, Yasuhiro; Nishioka, Akihito; Inomata, Taisuke; Yoshida, Shoji; Toki, Taiichi [Kochi Medical School, Nangoku (Japan)

    1996-12-01

    A retrospective study was performed to determine whether thin section CT scanning in the prone position of the breast and the axilla yield useful information regarding the status of axillary lymph nodes in patients with breast cancer. Thirty-six patients with breast carcinomas were scanned preoperatively from the supraclavicular regions to the breast in the prone position with 5 mm sections. Axillary lymph nodes measuring {>=}5 mm on the short axis were considered abnormal. Correlation with axillary dissection was obtained in all patients, giving a positive predictive value for axillary metastases of 83.3%, with 88.2% sensitivity, 84.2% specificity, and 88.8% negative predictive value. We concluded that thin section CT scan in the prone position was an accurate predictor of axillary lymph node involvement. We made a phantom with lymph node swelling to evaluate whether CT scanning with 5 mm sections was necessary for detecting 5 mm swollen lymph nodes. We scanned the phantom with 5 mm and 10 mm sections. Twelve radiologists counted the swollen lymph nodes on 5 mm section images and 10 mm section images of the phantom. The average number of miscounts was 1.1 (miscount rate 6.8%) on 5 mm section and 2.8 (15%) on 10 mm sections. We conclued that 5 mm section CT scanning is superior for detecting 5 mm lymph nodes. (author)

  15. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Poul Henning [Vejle Hospital, Department of Medicine, Division of Respiratory Medicine, Vejle (Denmark); Holdgaard, Paw Christian [Vejle Hospital, Department of Nuclear Medicine, Vejle (Denmark); Christensen, Janne Buck [Odense University Hospital/University of Southern Denmark, Department of Quality and Research/HTA, Odense University Hospital and Medical Research Library, Odense (Denmark); Hoeilund-Carlsen, Poul Flemming [Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark)

    2016-10-15

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: (1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). (2) PET-CT reduces the number of futile treatment trials (recommendation level A). (3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). (1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (<1 cm) and non-solid, solitary pulmonary nodules. These abnormalities should be followed up by CT in a structured programme. (2) No curative-intent treatment should be commenced until a PET-CT scan has excluded occult distant metastases. (3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out. (orig.)

  16. CT Perfusion ASPECTS in the Evaluation of Acute Ischemic Stroke: Thrombolytic Therapy Perspective

    Directory of Open Access Journals (Sweden)

    Niko Sillanpaa

    2011-02-01

    Full Text Available Background and Purpose: Advances in the management of acute ischemic stroke and medical imaging are creating pressure to replace the rigid one-third middle cerebral artery (MCA and non-contrast-enhanced CT (NCCT Alberta Stroke Program Early CT Score (ASPECTS thresholds used for the selection of patients eligible for intravenous thrombolytic therapy. The identification of potentially salvageable ischemic brain tissue lies at the core of this issue. In this study, the role of CT perfusion ASPECTS in the detection of reversible ischemia was analyzed. Materials and Methods: We retrospectively reviewed the clinical and imaging data of 92 consecutive patients who received intravenous thrombolytic therapy for acute (duration Results: A perfusion defect could be detected in 50% of the patients. ASPECTS correlated inversely with the clinical outcome in the following order: follow-up NCCT > cerebral blood volume (CBV > mean transit time (MTT > admission NCCT. The follow-up NCCT and the CBV displayed a statistically significant difference from the admission NCCT, while the MTT did not reach statistical significance. The threshold that best differentiated between good and bad clinical outcome on admission was CBV ASPECTS ≧7. In patients with CT perfusion ASPECTS mismatch, MTT and CBV ASPECTS essentially provided the lower and upper limits for the follow-up NCCT ASPECTS, thus defining the spectrum of possible outcomes. Furthermore, CT perfusion ASPECTS mismatch strongly correlated (r = 0.83 with the mismatch between the tissue at risk and the final infarct, i.e. the amount of salvaged tissue. This finding suggests that the CT perfusion ASPECTS mismatch adequately identifies the amount of potentially salvageable ischemic brain tissue. Conclusions: Parameters derived from the use of CT perfusion ASPECTS can detect reversible ischemia and are correlated with clinical outcome.

  17. Evaluation of stent visibility by flat panel detector CT in patients treated for intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Clarencon, Frederic [Groupe Hospitalier Pitie-Salpetriere, Paris (France); Pitie-Salpetriere Hospital, Department of Neuroradiology, Paris (France); Piotin, Michel; Pistocchi, Silvia; Blanc, Raphael [Fondation A. de Rothschild, Paris (France); Babic, Drazenko [Philips Healthcare, Best (Netherlands)

    2012-10-15

    This study aimed to evaluate the visibility of stents using high-resolution computed tomography (CT) acquisitions acquired with flat panel detector (XperCT, Allura series, Philips Healthcare, The Netherlands) for endovascular treatment of intracranial aneurysms. On a 24-month period, 48 patients endovascularly treated by coiling and stenting (59 stents) for intracranial aneurysms were explored by flat panel detector CT technique. A sequence of 620 2D images was acquired over an angle of 240 using a 1,024 x 1,024 pixel matrix detector within a 48-cm field of view. The images were retrospectively analyzed independently by two neuroradiologists. Evaluation criteria were percentage of visualization of the stents and stent deployment (kinking or unsatisfactory deployment of the stent). Evaluation of the stent was feasible for all the patients. Stent visibility by XperCT was overall estimated at 76% of the stent length. Difficulties to analyze the stents were related to coil artifacts but not to packing density or aneurysm location. Stent length visualization was higher when the acquisition was performed before additional coiling (P < 0.0001). Mild kinking/misdeployment was noticed in 22% of the cases. XperCT technique provides multiplanar and 3D reconstructions that allows for a satisfying visualization of intracranial stents. This CT-like acquisition should be performed after the stent deployment and before coiling, in order to obtain better stent visualization. (orig.)

  18. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  19. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  20. Effects of acupuncture evaluated by EEG topogram and positron CT

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Kazu; Yano, Tadashi (Meiji Coll. of Oriental Medicine, Hiyoshi, Kyoto (Japan))

    1990-02-01

    Electroencephalographic (EEG) topography and positron CT were performed in 30 subjects to examine the effects of needle stimulation on the function of the central nervous system. Needle stimulation was administered to IC{sub 10} Shousanli-IC{sub 4} Hoku, bilateral VF{sub 12} Head-Wanku, and G{sub 36} Tsusanli-LP{sub 6} Shanyinchiao at a frequency of 2 Hz. Changes in EEG power were observed in all cortical regions, especially in the area from the frontal to the occipital lobe. The subjects could be divided into two types - the type in which the power increased only in the {alpha} zone, and the type in which the power increased in both {theta} and {alpha} zones. Positron CT revealed that 'de-qi' (the acupuncture feeling) transiently invigorates the paleocortex and the neocortex, and exerts influences on a wide range of cranial nervous cells via the A{sub 10} nerve. Variation in regional cerebral blood flow induced by the electric needle stimulation was 15-20 ml/100 g brain tissue/min on average. Comfortable stimulation by the needle method is effective in eliminating disharmony between the neocortex and the paleocortex, regulating the function of the autonomic nerves, and stabilizing the spirit. (N.K.).

  1. Relationship between CT findings and electroencephalograms of children with cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Hirata, Yoshiaki; Nakano, Masao; Soumiya, Kyoichi; Ito, Masamitsu; Asano, Seiji (Hamamatsu Medical Center Hospital, Shizuoka (Japan)); Tsukimura, Yasuharu

    1983-10-01

    Electroencephalograms and CT findings of 43 infants with cerebral palsy were evaluated. Nineteen of them (44%) had abnormal findings of CT. The incidences of epileptic attacks and abnormal electroencephalograms were 33% and 84% in each group, respectively, with no differences between a normal-CT group and an abnormal-CT one. In electroencephalograms, positive spikes did not correlate with abnormal CT findings, but abnormal basal waves, particularly, low voltage dysrhythmia did well. Lazy activity also correlated with the abnormal CT findings.

  2. Evaluation of the OSC-TV iterative reconstruction algorithm for cone-beam optical CT

    Energy Technology Data Exchange (ETDEWEB)

    Matenine, Dmitri, E-mail: dmitri.matenine.1@ulaval.ca; Mascolo-Fortin, Julia, E-mail: julia.mascolo-fortin.1@ulaval.ca [Département de physique, de génie physique et d’optique, Université Laval, Québec, Québec G1V 0A6 (Canada); Goussard, Yves, E-mail: yves.goussard@polymtl.ca [Département de génie électrique/Institut de génie biomédical, École Polytechnique de Montréal, C.P. 6079, succ. Centre-ville, Montréal, Québec H3C 3A7 (Canada); Després, Philippe, E-mail: philippe.despres@phy.ulaval.ca [Département de physique, de génie physique et d’optique and Centre de recherche sur le cancer, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie and Centre de recherche du CHU de Québec, Québec, Québec G1R 2J6 (Canada)

    2015-11-15

    Purpose: The present work evaluates an iterative reconstruction approach, namely, the ordered subsets convex (OSC) algorithm with regularization via total variation (TV) minimization in the field of cone-beam optical computed tomography (optical CT). One of the uses of optical CT is gel-based 3D dosimetry for radiation therapy, where it is employed to map dose distributions in radiosensitive gels. Model-based iterative reconstruction may improve optical CT image quality and contribute to a wider use of optical CT in clinical gel dosimetry. Methods: This algorithm was evaluated using experimental data acquired by a cone-beam optical CT system, as well as complementary numerical simulations. A fast GPU implementation of OSC-TV was used to achieve reconstruction times comparable to those of conventional filtered backprojection. Images obtained via OSC-TV were compared with the corresponding filtered backprojections. Spatial resolution and uniformity phantoms were scanned and respective reconstructions were subject to evaluation of the modulation transfer function, image uniformity, and accuracy. The artifacts due to refraction and total signal loss from opaque objects were also studied. Results: The cone-beam optical CT data reconstructions showed that OSC-TV outperforms filtered backprojection in terms of image quality, thanks to a model-based simulation of the photon attenuation process. It was shown to significantly improve the image spatial resolution and reduce image noise. The accuracy of the estimation of linear attenuation coefficients remained similar to that obtained via filtered backprojection. Certain image artifacts due to opaque objects were reduced. Nevertheless, the common artifact due to the gel container walls could not be eliminated. Conclusions: The use of iterative reconstruction improves cone-beam optical CT image quality in many ways. The comparisons between OSC-TV and filtered backprojection presented in this paper demonstrate that OSC-TV can

  3. Comparative study between subjective assessment and quantitative evaluation of CT findings with cerebral palsy

    Energy Technology Data Exchange (ETDEWEB)

    Sugie, Y.; Sugie, H.; Kitai, A.; Maruyama, H.; Fukuyama, Y. (Tokyo Women' s Medical Coll. (Japan))

    1982-07-01

    Computed tomography (CT) was performed on 200 children with cerebral palsy with Hitachi CT-H250. The CT scans of 136 cases revealed cerebral atrophy with ventricular and/or subarachnoid space enlargement. The lateral ventricles, the third ventricle and the two parts of subarachnoid space on the CT picture were subjectively evaluated and divided into five grades ranging from no enlargement to marked enlargement. In addition, the size of the ventricles and the subarachnoid spaces were quantitatively determined; the transverse diameter of brain (b), the largest width of the anterior horns of the lateral ventricles (c), the bicaudate nuclear distance (d), the greatest width of the third ventricle, the longitudinal cerebral fissure and sylvian fissures as described by Miyao et al. (1978). Comparison of these quantitative techniques confirmed the initial subjective evaluation. However, in some cases, amendment of the subjective evaluation was needed. As mentioned before (Miyao et al.), the cerebral longitudinal fissure was relatively wide in normal infants. Accordingly, it was often difficult to find out abnormal widening only by subjective evaluation. The purpose of this paper was to establish the criteria of quantitative measuring and assessing of the lateral and third ventricles, the cerebral longitudinal fissures, and the sylvian fissures enlargement. Interpretation of some problem cases associated with measuring was also discussed. The quantitative CT evaluation may be a good reference in assessing cerebral atrophy in cerebral palsy and other neurological diseases.

  4. Accuracy of hepatocellular carcinoma detection on multidetector CT in a transplant liver population with explant liver correlation

    Energy Technology Data Exchange (ETDEWEB)

    Addley, H.C., E-mail: helenclareaddley@hotmail.co.u [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Griffin, N.; Shaw, A.S.; Mannelli, L. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Parker, R.A. [Department of Medical Statistics, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Aitken, S.; Wood, H. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Davies, S. [Department of Histopathology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Alexander, G.J. [Department of Hepatology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); Lomas, D.J. [Department of Radiology, Addenbrooke' s Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom)

    2011-04-15

    Aim: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for hepatocellular carcinoma (HCC) in cirrhotic patients undergoing liver transplantation. Secondary aims were to examine the effect of radiologist experience and lesion size on diagnostic accuracy. Materials and methods: Thirty-nine patients (72% male with a mean age of 56.5 years) underwent liver transplantation following preoperative triple-phase MDCT examination of the liver. MDCT examinations were retrospectively independently reviewed by three radiologists for the presence and location of suspected HCCs, with the diagnostic confidence recorded using a five-point confidence scale. MDCT examinations were compared with explant specimens for histopathological correlation. Results: Histopathological results demonstrated 46 HCCs in 29 of the 39 patients. Analysis demonstrated a sensitivity of 65-75% and specificity of 47-88% for detection of HCC lesions. The sensitivity dropped to 48-57% for lesions of size {<=}20 mm. As the diagnostic confidence increased, there was a further decrease in the sensitivity (4-26%). The radiologist with the greatest number of years experience was found to have a significantly higher accuracy of detection of HCC lesions compared with the least experienced radiologist. Conclusion: Larger lesion size of HCC and greater number of years experience of the radiologist resulted in significantly higher accuracy of HCC lesion detection. The overall sensitivity and specificity results for MDCT detection of HCC are comparable to previous helical CT imaging.

  5. Nuclear magnetic resonance imaging with cardiac synchronization in chronic thrombosis of main pulmonary arteries. A case review with CT scan imaging correlation

    Energy Technology Data Exchange (ETDEWEB)

    Coulomb, M.; Wolf, J.E.; Rose-Pittet, L.; Le Bas, J.F.; Dalsoglio, S.; Paramelle, B.

    Results of nuclear magnetic resonance exploration in a patient with chronic thrombosis of main pulmonary arteries are used to outline an elementary semiology in agreement with current documented data. Signs observed relate to the thrombosis and showing of flow due to associated pulmonary artery hypertension. Cardiac synchronization is essential: obtaining 2 echos by the spin-echo technique allows differentiation of circulatory slowing phenomena, which provoke increased strength of 2nd echo, from the thrombus itself. Correlations established with V/Q scintigraphy, angiography and CT scan findings in this case provided preliminary evaluation of use of this imaging technique in this affection.

  6. Temporal evolution of multidetector CT findings after endoscopic submucosal dissection in patients with early gastric cancer: Correlation with endoscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, Dong Myung, E-mail: duehdaud@gmail.com [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Chung, Dong Jin, E-mail: bookdoo7@catholic.ac.kr [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Cheung, Dae Young, E-mail: adagio@catholic.ac.kr [Department of Internal Medicine, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of); Lee, Jae Mun, E-mail: jaemun@catholic.ac.kr [Department of Radiology, Yeouido St. Mary' s Hospital, The Catholic University of Korea (Korea, Republic of)

    2014-06-15

    Objective: To assess changes over time in imaging findings retrospectively by multidetector CT (MDCT) with two-dimensional (2D) multiplanar reconstruction and three-dimensional (3D) CT gastrography (CTG), after endoscopic submucosal dissection (ESD) in patients with early gastric cancer (EGC), and to correlate 3D CT images with endoscopic appearance. Materials and methods: In this retrospective study, a total of 84 patients underwent ESD and were followed up with MDCT. Fifteen patients underwent CT twice, and 3 patients underwent CT 3 times. A total of 105 CTs were included in this study and 43 CTs contained 3D CTGs. Two radiologists in consensus interpreted CT images for lesion detectability, presence and characteristics of ulcer, focal wall thickening, perigastric fat infiltration, and overlying enhancing layer in 2D images. The presence of ulcer or subtle mucosal nodularity, ulcer mound, and fold convergence were analysed in 3D CT images. We also assessed the time interval between ESD and CT and analysed the temporal evolution of CT findings. The sensitivity, specificity, and overall accuracy of 3D CTG were assessed regarding endoscopic features as the gold standard. Results: The mean interval between ESD and follow up CT was 76.9 days (median, 62; range, 2–223). No tumour recurrence in any lesion was found on follow-up endoscopic biopsy and also lymph node or distant metastasis was not observed on CT exams in the follow-up period. The lesion detectability in a total of 105 post-ESD 2D CT images was 42.0% (44/105), and 93.2% (41/44) of the detected lesions were visualizable 2 months after ESD. Focal wall thickening was observed during the entire follow-up period in all patients. Perigastric fat infiltration was observed in 4 lesions within 1 week of ESD. Overlying enhancing layer appeared in 27 lesions without temporal evolution. On a total of 43 post-ESD 3D CTG, lesion detectability was 76.7% (33/43), and lesions could be visualized for a longer period than

  7. Extraction of 3D Femur Neck Trabecular Bone Architecture from Clinical CT Images in Osteoporotic Evaluation: a Novel Framework.

    Science.gov (United States)

    Sapthagirivasan, V; Anburajan, M; Janarthanam, S

    2015-08-01

    The early detection of osteoporosis risk enhances the lifespan and quality of life of an individual. A reasonable in-vivo assessment of trabecular bone strength at the proximal femur helps to evaluate the fracture risk and henceforth, to understand the associated structural dynamics on occurrence of osteoporosis. The main aim of our study was to develop a framework to automatically determine the trabecular bone strength from clinical femur CT images and thereby to estimate its correlation with BMD. All the 50 studied south Indian female subjects aged 30 to 80 years underwent CT and DXA measurements at right femur region. Initially, the original CT slices were intensified and active contour model was utilised for the extraction of the neck region. After processing through a novel process called trabecular enrichment approach (TEA), the three dimensional (3D) trabecular features were extracted. The extracted 3D trabecular features, such as volume fraction (VF), solidity of delta points (SDP) and boundness, demonstrated a significant correlation with femoral neck bone mineral density (r = 0.551, r = 0.432, r = 0.552 respectively) at p TEA method would be useful for spotting women vulnerable to osteoporotic risk.

  8. Extensive Invasive Extramammary Paget Disease Evaluated by F-18 FDG PET/CT

    Science.gov (United States)

    Li, Zu-Gui; Qin, Xiao-Jing

    2015-01-01

    Abstract Extramammary Paget disease (EMPD) is a rare cutaneous, intraepithelial adenocarcinoma. Because of its rarity, little is known about the value of fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in evaluating this disease. Our case report aims to increase current knowledge of FDG PET/CT in EMPD as a noninvasive imaging tool for assessing the extension of the disease and detecting distant metastases. We reported a 64-year-old Chinese man who presented with a slowly progressive, ill-margined erythematous lesion with a crusted, eroded, and scaly surface involving multiple sites of penis, scrotum, left pelvic wall, hip, groin, and thigh for >4 years, which became extensive in the past 1 year. He was referred for an FDG PET/CT examination to further evaluate the lesions. A following skin biopsy was performed to obtain a definitive histological diagnosis. FDG PET/CT imaging revealed mild FDG uptake at the extensive cutaneous lesion with subcutaneous invasion, involvement of lymph nodes, and multiple intense FDG-avid of skeletal metastases. According to the appearance of FDG PET/CT, a provisional diagnosis of advanced cutaneous malignancy was made. Histopathology findings indicated characteristic of EMPD. The patient was treated with radiation therapy and died from complications 2 months after the last dose of radiotherapy. Our case highlighted that a whole-body FDG PET/CT should be incorporated into the diagnostic algorithm of EMPD to give a comprehensive assessment of this disease. PMID:25621679

  9. Extensive invasive extramammary Paget disease evaluated by F-18 FDG PET/CT: a case report.

    Science.gov (United States)

    Li, Zu-Gui; Qin, Xiao-Jing

    2015-01-01

    Extramammary Paget disease (EMPD) is a rare cutaneous, intraepithelial adenocarcinoma. Because of its rarity, little is known about the value of fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in evaluating this disease. Our case report aims to increase current knowledge of FDG PET/CT in EMPD as a noninvasive imaging tool for assessing the extension of the disease and detecting distant metastases.We reported a 64-year-old Chinese man who presented with a slowly progressive, ill-margined erythematous lesion with a crusted, eroded, and scaly surface involving multiple sites of penis, scrotum, left pelvic wall, hip, groin, and thigh for >4 years, which became extensive in the past 1 year. He was referred for an FDG PET/CT examination to further evaluate the lesions. A following skin biopsy was performed to obtain a definitive histological diagnosis.FDG PET/CT imaging revealed mild FDG uptake at the extensive cutaneous lesion with subcutaneous invasion, involvement of lymph nodes, and multiple intense FDG-avid of skeletal metastases. According to the appearance of FDG PET/CT, a provisional diagnosis of advanced cutaneous malignancy was made. Histopathology findings indicated characteristic of EMPD. The patient was treated with radiation therapy and died from complications 2 months after the last dose of radiotherapy.Our case highlighted that a whole-body FDG PET/CT should be incorporated into the diagnostic algorithm of EMPD to give a comprehensive assessment of this disease.

  10. A careful evaluation of scout CT lateral radiograph may prevent unreported vertebral fractures

    Energy Technology Data Exchange (ETDEWEB)

    Bazzocchi, Alberto; Spinnato, Paolo [Imaging Division, Clinical Department of Radiological and Histocytopathological Sciences, University of Bologna, Sant’Orsola – Malpighi Hospital, Via Massarenti 9, 40138 Bologna (Italy); Albisinni, Ugo [Department of Radiology, Rizzoli Orthopaedic Institute, Via Pupilli 1, 40136 Bologna (Italy); Battista, Giuseppe [Imaging Division, Clinical Department of Radiological and Histocytopathological Sciences, University of Bologna, Sant’Orsola – Malpighi Hospital, Via Massarenti 9, 40138 Bologna (Italy); Rossi, Cristina [Section of Radiological Sciences, Department of Clinic Sciences, University of Parma, Via Gramsci 14, 43100 Parma (Italy); Guglielmi, Giuseppe, E-mail: g.guglielmi@unifg.it [Department of Radiology, University of Foggia, Viale Luigi Pinto 1, 71100 Foggia (Italy); Department of Radiology, Scientific Institute “Casa Sollievo della Sofferenza” Hospital, Viale Cappuccini 1, 71013 San Giovanni Rotondo, Foggia (Italy)

    2012-09-15

    Objectives: Our purpose was to review scout CT lateral radiographs to reveal osteoporotic vertebral fractures unreported by radiologists and to explore scout CT as a potential diagnostic tool in the detection of vertebral fractures. Methods: We considered 500 patients (303 males, 197 females, age 64.6 ± 13.5 year-old). Our investigation was firstly focused on scout CT lateral images to detect vertebral fractures with a combined semiquantitative and quantitative diagnostic approach. Findings addressed to vertebral fracture were subsequently confirmed by multiplanar sagittal CT reconstructions. Whenever a vertebral fracture was discovered the radiologist report was read and a collection of patient anamnesis followed to understand whether fractures were already known. Results: In 44/500 patients (8.8%) the evaluation on scout CT was incomplete or limited for patient/technical-based conditions, and 15 were excluded from the analysis. In 67/485 patients (13.8%) 99 vertebral fractures were detected. Among 67 fractured patients only 18 (26.9%) were previously diagnosed by radiologists. However, in the clinical history of 32 patients vertebral fractures were already known. Conclusions: The perception and sensibility to vertebral fractures among radiologists are still poor when the assessment of the spine is not the aim of the examination. Short time spent for the evaluation of scout CT lateral radiographs could improve our accuracy.

  11. Evaluation of thymic tumors with 18F-FDG PET-CT - A pictorial review

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Punit; Singhal, Abhinav; Bal, Chandrasekhar; Malhotra, Arun; Kumar, Rakesh [Dept. of Nuclear Medicine, All India Inst. of Medical Sciences, New Delhi (India)], e-mail: rkphulia@yahoo.com; Kumar, Arvind [Dept. of Surgical Disciplines, All India Inst. of Medical Sciences, New Delhi (India)

    2013-02-15

    Thymic tumors represent a broad spectrum of neoplastic disorders and pose considerable diagnostic difficulties. A non-invasive imaging study to determine the nature of thymic lesions can have significant impact on management of such tumors. 18F-flurorodeoxyglucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) has shown promising results in characterization of thymic tumors. The objective of this article is to provide an illustrative tutorial highlighting the clinical utility of 18F-FDG PET-CT imaging in patients with thymic tumors. We have pictorially depicted the 18F-FDG PET-CT salient imaging characteristics of various thymic tumors, both epithelial and non-epithelial. Also discussed is the dynamic physiology of thymus gland which is to be kept in mind when evaluating thymic pathology on 18F-FDG PET-CT, as it can lead to interpretative pitfalls.

  12. Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: Preoperative classification accuracy and histopathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Xyda, Argyro, E-mail: argyro.xyda@med.uni-goettingen.de [Department of Neuroradiology, Georg-August University, University Hospital of Goettingen, Robert-Koch Strasse 40, 37075 Goettingen (Germany); Department of Radialogy, University Hospital of Heraklion, Voutes, 71110 Heraklion, Crete (Greece); Haberland, Ulrike, E-mail: ulrike.haberland@siemens.com [Siemens AG Healthcare Sector, Computed Tomography, Siemensstr. 1, 91301 Forchheim (Germany); Klotz, Ernst, E-mail: ernst.klotz@siemens.com [Siemens AG Healthcare Sector, Computed Tomography, Siemensstr. 1, 91301 Forchheim (Germany); Jung, Klaus, E-mail: kjung1@uni-goettingen.de [Department of Medical Statistics, Georg-August University, Humboldtallee 32, 37073 Goettingen (Germany); Bock, Hans Christoph, E-mail: cbock@gmx.de [Department of Neurosurgery, Johannes Gutenberg University Hospital of Mainz, Langenbeckstraße 1, 55101 Mainz (Germany); Schramm, Ramona, E-mail: ramona.schramm@med.uni-goettingen.de [Department of Neuroradiology, Georg-August University, University Hospital of Goettingen, Robert-Koch Strasse 40, 37075 Goettingen (Germany); Knauth, Michael, E-mail: michael.knauth@med.uni-goettingen.de [Department of Neuroradiology, Georg-August University, University Hospital of Goettingen, Robert-Koch Strasse 40, 37075 Goettingen (Germany); Schramm, Peter, E-mail: p.schramm@med.uni-goettingen.de [Department of Neuroradiology, Georg-August University, University Hospital of Goettingen, Robert-Koch Strasse 40, 37075 Goettingen (Germany)

    2012-12-15

    Background: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. Results: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100 mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. Conclusion: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.

  13. Evaluation of Registration Methods on Thoracic CT : The EMPIRE10 Challenge

    NARCIS (Netherlands)

    Murphy, Keelin; van Ginneken, Bram; Reinhardt, Joseph M.; Kabus, Sven; Ding, Kai; Deng, Xiang; Cao, Kunlin; Du, Kaifang; Christensen, Gary E.; Garcia, Vincent; Vercauteren, Tom; Ayache, Nicholas; Commowick, Olivier; Malandain, Gregoire; Glocker, Ben; Paragios, Nikos; Navab, Nassir; Gorbunova, Vladlena; Sporring, Jon; de Bruijne, Marleen; Han, Xiao; Heinrich, Mattias P.; Schnabel, Julia A.; Jenkinson, Mark; Lorenz, Cristian; Modat, Marc; McClelland, Jamie R.; Ourselin, Sebastien; Muenzing, Sascha E. A.; Viergever, Max A.; De Nigris, Dante; Collins, D. Louis; Arbel, Tal; Peroni, Marta; Li, Rui; Sharp, Gregory C.; Schmidt-Richberg, Alexander; Ehrhardt, Jan; Werner, Rene; Smeets, Dirk; Loeckx, Dirk; Song, Gang; Tustison, Nicholas; Avants, Brian; Gee, James C.; Staring, Marius; Klein, Stefan; Stoel, Berend C.; Urschler, Martin; Werlberger, Manuel; Vandemeulebroucke, Jef; Rit, Simon; Sarrut, David; Pluim, Josien P. W.

    2011-01-01

    EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intrapatient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This

  14. Evaluation of respiration-correlated digital tomosynthesis in lung1

    Science.gov (United States)

    Santoro, Joseph; Kriminski, Sergey; Lovelock, D. Michael; Rosenzweig, Kenneth; Mostafavi, Hassan; Amols, Howard I.; Mageras, Gig S.

    2010-01-01

    Digital tomosynthesis (DTS) with a linear accelerator-mounted imaging system provides a means of reconstructing tomographic images from radiographic projections over a limited gantry arc, thus requiring only a few seconds to acquire. Its application in the thorax, however, often results in blurred images from respiration-induced motion. This work evaluates the feasibility of respiration-correlated (RC) DTS for soft-tissue visualization and patient positioning. Image data acquired with a gantry-mounted kilovoltage imaging system while recording respiration were retrospectively analyzed from patients receiving radiotherapy for non-small-cell lung carcinoma. Projection images spanning an approximately 30° gantry arc were sorted into four respiration phase bins prior to DTS reconstruction, which uses a backprojection, followed by a procedure to suppress structures above and below the reconstruction plane of interest. The DTS images were reconstructed in planes at different depths through the patient and normal to a user-selected angle close to the center of the arc. The localization accuracy of RC-DTS was assessed via a comparison with CBCT. Evaluation of RC-DTS in eight tumors shows visible reduction in image blur caused by the respiratory motion. It also allows the visualization of tumor motion extent. The best image quality is achieved at the end-exhalation phase of the respiratory motion. Comparison of RC-DTS with respiration-correlated cone-beam CT in determining tumor position, motion extent and displacement between treatment sessions shows agreement in most cases within 2–3 mm, comparable in magnitude to the intraobserver repeatability of the measurement. These results suggest the method’s applicability for soft-tissue image guidance in lung, but must be confirmed with further studies in larger numbers of patients. PMID:20384261

  15. Honeycombing on CT; its definition, pathologic correlation, and future direction of its diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Johkoh, Takeshi, E-mail: johkoht@aol.com [Department of Radiology, Kinki Central Hospital of Mutual Aid Association of Public School Teachers, 3-1 Kurumazuka, Itami, Hyogo, 664-8533 (Japan); Sakai, Fumikazu [Department of Diagnostic Radiology, Saitama International Medical Center, Saitama Medical University, Hidaka (Japan); Noma, Satoshi [Department of Radiology, Tenri Hospital, Tenri (Japan); Akira, Masanori [Department of Radiology, National Hospital Organization Kinki-Chuo Chest Medical Center, Sakai (Japan); Fujimoto, Kiminori [Department of Radiology and Center for Diagnostic Imaging, Kurume University School of Medicine, Kurume (Japan); Watadani, Takeyuki [Department of Radiology, University of Tokyo, Tokyo (Japan); Sugiyama, Yukihiko [Department of Internal Medicine, Jichi Medical University, Shimotsuke (Japan)

    2014-01-15

    Honeycombing on CT is the clue for the diagnosis of usual interstitial pneumonia (UIP) and its hallmark. According to the ATS-ERS-JRS-ALAT 2010 guideline, the patients with honeycombing on CT can be diagnosed as UIP without surgical biopsy. On CT scans, it is defined as clustered cystic airspaces, typically of comparable diameters of the order of 3–10 mm, which are usually subpleural and have well-defined walls. Pathologically, honeycombing consists of both collapsing of multiple fibrotic alveoli and dilation of alveolar duct and lumen Although the definition of honeycombing seems to be strict, recognition of honeycombing on CT is various among each observer Because typical honeycombing is frequently observed in the patients with UIP, we should judge clustered cysts as honeycombing when a diagnosis of UIP is suspected.

  16. Correlation between (18)F-FDG uptake on PET/CT and prognostic factors in triple-negative breast cancer.

    Science.gov (United States)

    Koo, Hye Ryoung; Park, Jeong Seon; Kang, Keon Wook; Han, Wonshik; Park, In Ae; Moon, Woo Kyung

    2015-11-01

    The purpose of this study was to investigate whether a correlation exists between (18)F-fluorodeoxyglucose (FDG) uptake and prognostic factors in triple-negative breast cancer (TNBC). Between January 2009 and December 2013, 103 patients (mean age, 50.6 years) with primary TNBC (mean, 2.6 cm; range, 1.0-6.5 cm) underwent (18)F-FDG PET/CT for initial staging. Correlations between maximum standardized uptake value (SUVmax) on PET/CT and prognostic factors including tumour size, nodal status, histological grade, Ki-67 proliferation index, tumour suppressor p53, and 'basal-like' markers (epidermal growth factor receptor and CK 5/6) were assessed. The mean SUVmax of the 103 tumours was 10.94 ± 5.25 (range: 2-32.8). There was a positive correlation between SUVmax and Ki-67 (Spearman's rho = 0.29, P = 0.003) and tumour size (Spearman's rho = 0.27, P = 0.006), whereas this relationship was not observed in the nodal status, histological grade, p53 status and 'basal-like' phenotypes. In a multivariate regression analysis, Ki-67 (P correlated with a high Ki-67 proliferation index and larger tumour size in TNBC. These results suggest a potential role of (18)F-FDG PET/CT in identifying TNBC with more aggressive behaviour. • A wide range of FDG uptake reflected heterogeneity of cancer metabolism. • FDG uptake was correlated with the Ki-67 proliferation index in TNBC. • FDG uptake was correlated with tumour size in TNBC. • FDG uptake was not correlated with 'basal-like' phenotype.

  17. Normal CT morphology of the adrenal gland; Evaluation with thin-slice CT using a small field of view

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Eriko (Tokyo Women' s Medical Coll. (Japan))

    1993-11-01

    This study was performed to determine the normal morphology and dimensions of the adrenal gland by studying 111 normal individuals using thin-slice CT with a small field of view. All the adrenal glands were well demonstrated and the medial and lateral limbs were recognized in 95.4% of the right adrenal glands. The outer border of the gland was generally straight or concave, although the caudal surface was convex in 25% of right and 50% of left adrenal glands. The height, thickness, and width of the gland were measured at multiple levels on both sides, and the results were compared with those for atrophic glands (21 Cushing's syndrome patients) and hypertrophic glands (8 patients). Multivariate analysis showed that the best features distinguishing between normal and atrophy were the height at the midpoint on the left side and the thickness of the ridge on the right side. Normal and hypertrophic glands could be distinguished by the thickness of the median limb at its upper portion and lower portion on the right side. On the left side, the thickness at the upper portion, the thickness of the ridge, and that of the median limb at its midpoint were the distinguishing features. It was concluded that thin-slice CT using a small field of view can accurately assess adrenal morphology and thus is useful for evaluating atrophy and hypertrophy. (author).

  18. Single-portal-phase low-tube-voltage dual-energy CT for short-term follow-up of acute pancreatitis: evaluation of CT severity index, interobserver agreement and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Wichmann, Julian L. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Universitaetsklinikum Frankfurt, Institut fuer Diagnostische und Interventionelle Radiologie, Frankfurt am Main (Germany); Majenka, Pawel; Beeres, Martin; Kromen, Wolfgang; Schulz, Boris; Bauer, Ralf W.; Kerl, J.M.; Gruber-Rouh, Tatjana; Hammerstingl, Renate; Vogl, Thomas J.; Lehnert, Thomas [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt am Main (Germany); Wesarg, Stefan [Fraunhofer IGD, Cognitive Computing and Medical Imaging, Darmstadt (Germany)

    2014-11-15

    To intra-individually compare single-portal-phase low-tube-voltage (100-kVp) computed tomography (CT) with 120-kVp images for short-term follow-up assessment of CT severity index (CTSI) of acute pancreatitis, interobserver agreement and radiation dose. We retrospectively analysed 66 patients with acute pancreatitis who underwent initial dual-contrast-phase CT (unenhanced, arterial, portal phase) at admission and short-term (mean interval 11.4 days) follow-up dual-contrast-phase dual-energy CT. The 100-kVp and linearly blended images representing 120-kVp acquisition follow-up CT images were independently evaluated by three radiologists using a modified CTSI assessing pancreatic inflammation, necrosis and extrapancreatic complications. Scores were compared with paired t test and interobserver agreement was evaluated using intraclass correlation coefficients (ICC). Mean CTSI scores on unenhanced, portal- and dual-contrast-phase images were 4.9, 6.1 and 6.2 (120 kVp) and 5.0, 6.0 and 6.1 (100 kVp), respectively. Contrast-enhanced series showed a higher CTSI compared to unenhanced images (P < 0.05) but no significant differences between single- and dual-contrast-phase series (P > 0.7). CTSI scores were comparable for 100-kVp and 120-kVp images (P > 0.05). Interobserver agreement was substantial for all evaluated series and subcategories (ICC 0.67-0.93). DLP of single-portal-phase 100-kVp images was reduced by 41 % compared to 120-kVp images (363.8 versus 615.9 mGy cm). Low-tube-voltage single-phase 100-kVp CT provides sufficient information for follow-up evaluation of acute pancreatitis and significantly reduces radiation exposure. (orig.)

  19. Tc-99m labeled leukocyte scintigraphy and CT for the evaluation of patients with inflammatory bowel disease

    Energy Technology Data Exchange (ETDEWEB)

    Miyazaki, Chihoko; Kubo, Kohzoh; Aoyama, Hidefumi; Endoh, Hideho; Odashima, Yae; Saitoh, Eri [Sapporo City General Hospital (Japan)

    1997-06-01

    Seventeen cases of inflammatory bowel disease (IBD) were studied to define the intensity and extent of disease by {sup 99m}Tc-HMPAO-labeled leukocytes scintigraphy (TLLS), and 10 cases underwent CT examination to evaluate the bowel wall, lymph-nodes, and mesenteric surroundings. Serial TLLS were obtained up to 4 hours and CT was carried out within one week before or after TLLS. The sensitivities to early and delayed TLLS were 91% and 100%, respectively. The respective specificities were 100% and 33%. However, it appeared that mild IBD may yield false negative results in early TLLS while nonspecific bowel activity and migration of white cells may cause false positive results in delayed imaging. By setting the diagnostic criteria for labeled leukocyte accumulation on visualization of the small bowel regardless of uptake or activity of the large bowel similar to or greater than lumbar bone marrow, the sensitivity and specificity of delayed TLLS changed to 91% and 83%, respectively. On CT examination, mesenteric lymph-node swelling, periintestinal blurring and dilatation of mesenteric vasa recta were observed in all five patients with active Crohn`s disease, while wall thickening and enhancement were seen in four of them. None of the other three cases of inflammatory disease showed positive findings of dilatation of the mesenteric vasa recta, and they revealed relatively low uptake of labeled leukocytes in TLLS. A `scintigram score` was calculated by comparing uptake of tracer in five bowel segments with lumbar bone marrow activity, and a `CT score` was calculated by adding abnormalities of the intestine and mesenteric surroundings. The scintigram score correlated closely with CT score and clinical disease activity. (K.H.)

  20. Correlation of CT-based regional cardiac function (SQUEEZ) with myocardial strain calculated from tagged MRI: an experimental study.

    Science.gov (United States)

    Pourmorteza, Amir; Chen, Marcus Y; van der Pals, Jesper; Arai, Andrew E; McVeigh, Elliot R

    2016-05-01

    The objective of this study was to investigate the correlation between local myocardial function estimates from CT and myocardial strain from tagged MRI in the same heart. Accurate detection of regional myocardial dysfunction can be an important finding in the diagnosis of functionally significant coronary artery disease. Tagged MRI is currently a reference standard for noninvasive regional myocardial function analysis; however, it has practical drawbacks. We have developed a CT imaging protocol and automated image analysis algorithm for estimating regional cardiac function from a few heartbeats. This method tracks the motion of the left ventricular (LV) endocardial surface to produce local function maps: we call the method Stretch Quantification of Endocardial Engraved Zones (SQUEEZ). Myocardial infarction was created by ligation of the left anterior descending coronary artery for 2 h followed by reperfusion in canine models. Tagged and cine MRI scans were performed during the reperfusion phase and first-pass contrast enhanced CT scans were acquired. The average delay between the CT and MRI scans was myocardial strain (Ecc) was calculated from the tagged MRI data. The agreement between peak systolic Ecc and SQUEEZ was investigated in 162 segments in the 9 hearts. Linear regression and Bland-Altman analysis was used to assess the correlation between the two metrics of local LV function. The results show good agreement between SQUEEZ and Ecc: (r = 0.71, slope = 0.78, p function. The good agreement between the estimates of local myocardial function obtained from CT SQUEEZ and tagged MRI provides encouragement to investigate the use of SQUEEZ for measuring regional cardiac function at a low clinical dose in humans.

  1. Study on the correlation between CT appearance and expression of p53 protein in peripheral lung cancer

    Institute of Scientific and Technical Information of China (English)

    CHEN Jiang-hao; HUANG Xue-sheng; LIU Kun; YANG Ning

    2001-01-01

    Objective: To investigate the correlation between CT appearance and expression of p53 protein in peripheral lung cancer. Methods: The expression of p53 protein was examined by means of SP immunohistochemical technique in 32 cases of peripheral lung cancer. Their correlation with the preoperative CT appearance was analyzed retrospectively.Results: The expression of p53 protein was correlated with tumor size, lobulation, cavitation, pleural indentation and mediastinal lymph node enlargement, but not with spiculation. Tumor with maximum diameter greater than 3 cm or with the presence oflobulation, cavitation, pleural indentation or mediastinal lymph node larger than 10 mm in short axis had a relatively higher level of p53 expression. Conclusion: CT signs of peripheral lung cancers are valuable not only in differentiating cancers from benign lesions, as known before, but also in providing further information for the malignant potential of cancers. Larger tumor size, lobulation, cavitation, pleural indentation, and mediastinal lymph node enlargement may be likely related to a higher degree of malignant potential and more aggressive tumor behavior.

  2. Multi-slice CT in the planning of nephron-sparing interventions for renal cell carcinoma: prospective study correlated with histopathology; Multi-Slice-CT in der Planung der organerhaltenden Operation des Nierenzellkarzinoms: Prospektive histopathologisch korrelierte Studie

    Energy Technology Data Exchange (ETDEWEB)

    Hallscheidt, P. [Forschungsschwerpunkt Radiologische Diagnostik und Therapie des Deutschen Krebsforschungszentrums, Heidelberg (Germany); Abt. Radiodiagnostik der Radiologischen Klinik der Univ. Heidelberg (Germany); Schoenberg, S.; Zuna, I. [Forschungsschwerpunkt Radiologische Diagnostik und Therapie des Deutschen Krebsforschungszentrums, Heidelberg (Germany); Schenk, J.P. [Abt. Radiodiagnostik der Radiologischen Klinik der Univ. Heidelberg (Germany); Petirsch, O.; Riedasch, G. [Urologische Klinik und Poliklinik der Univ. Heidelberg (Germany)

    2002-07-01

    Objective: For nephron sparing surgery of renal cell carcinoma knowledge of the intrarenal extension of the tumor and infiltration of the renal pelvis, the intrarenal vessels and the perinephric fat is essential. This question is much more difficult to answer compared to the description of staging parameters. Aim of this study is to evaluate the value of multi-slice CT in planning of nephron sparing surgery. Material and Methods: In a prospective study 46 patients with suspected renal cell carcinoma underwent a triphasic multi-slice CT (unenhanced, delay 30 s and 120 s). A reconstructed slice thickness of 2 mm in the arterial and parenchymal phase was used to create volume rendered 3D-reconstructions. Based on the source data and multiplanar reconstructed images the extent of the renal cell carcinoma was assessed in terms of size, hilar infiltration, arterial and venous invasions, capsula infiltration and perirenal growth. The results of two blinded readers were correlated with histopathological staging and intraoperative findings. Results: 36 carcinomas were evaluated histopathologically. 10 patients showed no renal cell carcinoma histopatholologically. Multi-slice CT allowed us to diagnose the localization and size of all tumors correctly. Infiltration into perinephric fat was correctly excluded in 24/30 and 8/30 cases. Infiltration of the renal pelvis could be excluded in 17/24 and 12/24 cases. The state of venous infiltration could be correctly diagnosed in 29/30 and 27 /30 carcinomas. Conclusion: Despite of the high temporal and spatial resolution of multi-slice CT, which allows the delineation of intrarenal arteries as well as renal hilus and the veins, the evaluation of tumor infiltration into the renal hilus, the intrarenal vessels and the perinephric fat remains a diagnostic problem. For planning of nephron sparing surgery, a knowledge of the infiltration in these structures is essential. (orig.) [German] Ziel: Fuer die Planung der organerhaltenden

  3. An evaluation of the use of oral contrast media in abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Buttigieg, Erica Lauren; Cortis, Kelvin; Galea Soler, Sandro [Mater Dei Hospital, Medical Imaging Department, Msida (Malta); Borg Grima, Karen; Zarb, Francis [Mater Dei Hospital, Faculty of Health Sciences, Msida (Malta)

    2014-11-15

    To evaluate the diagnostic efficacy of different oral contrast media (OCM) for abdominopelvic CT examinations performed for follow-up general oncological indications. The objectives were to establish anatomical image quality criteria for abdominopelvic CT; use these criteria to evaluate and compare image quality using positive OCM, neutral OCM and no OCM; and evaluate possible benefits for the medical imaging department. Forty-six adult patients attending a follow-up abdominopelvic CT for general oncological indications and who had a previous abdominopelvic CT with positive OCM (n = 46) were recruited and prospectively placed into either the water (n = 25) or no OCM (n = 21) group. Three radiologists performed absolute visual grading analysis (VGA) to assess image quality by grading the fulfilment of 24 anatomical image quality criteria. Visual grading characteristics (VGC) analysis of the data showed comparable image quality with regards to reproduction of abdominal structures, bowel discrimination, presence of artefacts, and visualization of the amount of intra-abdominal fat for the three OCM protocols. All three OCM protocols provided similar image quality for follow-up abdominopelvic CT for general oncological indications. (orig.)

  4. Correlation of the CT values of abdominal aorta,renal artery and renal cortex with its thickness on 64-MDCT contrast en-hanced images

    Institute of Scientific and Technical Information of China (English)

    Alomary Mahfooz-Naef; Vikash; Wang Qiu-xia; Zhang Jin-hua; Hu Dao-yu

    2015-01-01

    Objective:To investigate the correlation of abdominal aorta CT value,renal artery CT value and renal cor-tex thickness with renal cortex CT value on contrast enhanced 64-slice CT images.Methods:96 patients (50 men and 46 women;16~74 years)with normal kidney function,which was confirmed by kidney function test were enrolled in this stud-y,including bilateral kidneys of 92 cases and unilateral kidney of 4 cases (total of 188 kidneys;92 left,96 right).After intra-venous (IV)injection of contrast agent the kidneys of the selected patients were scanned by MDCT.The scans were per-formed in arterial,venous and 3min delayed phases.All statistical analyses were performed by using IBM SPSS 20.0.Graphs were generated using Graph Pad Prism 5 software.Quantitative data were presented as mean ± standard deviation,while qualitative data were presented as frequency (%).P<0.05 was considered to be statistically significant.Results:The mean renal cortex thickness was (5.19±0.81)mm in all kidneys.In the arterial phase,a statistically significant positive correla-tion between renal cortex CT values and abdominal aortic CT values was showed (r= 0.584;P<0.001).A statistically sig-nificant positive correlation between renal cortex CT values and renal cortex thickness was demonstrated (r= 0.533,P<0.0001).Likewise,there was a positive correlation between renal cortex CT value and renal artery CT values (r= 0.43,P<0.001).Conclusion:It is a promising approach to assess the individual kidney function by measuring abdominal aorta CT value,renal artery CT value,renal cortex CT value and renal cortex thickness using contrast MDCT.

  5. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Platon, Alexandra; Jlassi, Helmi; Becker, Christoph D.; Poletti, Pierre-Alexandre [University Hospital of Geneva, Department of Radiology, Geneva 14 (Switzerland); Rutschmann, Olivier T. [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Verdun, Francis R. [University Institute for Radiation Physics, Lausanne (Switzerland); Gervaz, Pascal [University Hospital of Geneva, Clinic of Digestive Surgery, Geneva (Switzerland)

    2009-02-15

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) {>=} 18.5. In slim patients (BMI < 18.5), sensitivity to diagnose appendicitis was 50% (2/4) for LDCT and 100% (4/4) for standard CT, while specificity was identical for both techniques (67%, 2/3). LDCT may play a role in the diagnostic workup of patients with a BMI {>=} 18.5. (orig.)

  6. Deep Inspiration Breath Hold [(18)F]FDG PET-CT on 4-rings scanners in evaluating lung lesions: evidences from a phantom and a clinical study.

    Science.gov (United States)

    Caobelli, Federico; Puta, Erinda; Kaiser, Stefano Ren; Massetti, Valentina; Andreoli, Michela; Mostarda, Angelica; Soffientini, Alberto; Pizzocaro, Claudio; Guerra, Ugo Paolo

    2014-01-01

    To investigate the clinical feasibility of a Deep Inspiration Breath Hold (DIBH) (18)F-FDG PET-CT acquisition in apnea and compare the results obtained between these acts of acquisition in apnea and in Free Breathing in the evaluation of lung lesions. A pre-clinical phantom study was performed to evaluate the shortest simulated DIBH time according to the minimum detectable lesion that can be detected by our ultrasound scanner. This study was conducted by changing acquisition time and sphere-to-background activity ratio values and by using radioactivity densities similar to those generally found in clinical examinations. In the clinical study, 25 patients with pulmonary lesions underwent a standard whole body (18)F-FDG PET-CT scan in free breathing followed by a 20s single thorax acquisition PET/CT in DIBH acquisition. The phantom study indicated that a 20-s acquisition time provides an accurate evaluation of smallest sphere shaped lesions. In the clinical study, PET-CT scans obtained in DIBH studies showed a significant reduction of misalignment between the PET and CT scan images and an increase of SUVmax compared to free breathing acquisitions. A correlation between the %BH-index and lesion displacement between PET and CT images in FB acquisition was demonstrated, significantly higher for lesions with a displacement>8mm. The single 20s acquisition of DIBH PET-CT is a feasible technique for lung lesion detection in the clinical setting. It only requires a minor increase in examination time without special patient training. 20s DIBH scan provided a more precise measurement of SUVmax, especially for lesions in the lower lung lobes which usually show greater displacement between PET and CT scan images in FB acquisition. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  7. Structural imaging of the pancreas in rat using micro-CT: application to a non-invasivelongitudinal evaluation of pancreatic ductal carcinoma monitoring

    Directory of Open Access Journals (Sweden)

    Akladios CY

    2013-04-01

    Full Text Available The aim of the study was to evaluate the feasibility of a longitudinal non-invasive monitoring of rat pancreatic ductal adenocarcinoma (PDAC using microCTscans (μCT. The identification of the pancreatic gland on (μCT was performed at first using contrast products (Fenestra LC and VC, v/v at a dosage of 0.5 ml/Kg of body weight. Then orthotopic PDAC developed in adult Lewis rat was detected and monitored. In vivo μCT measurement of tumor was compared to actual size ex vivo in 12 rats. Gemcitabine treatment of PDAC was monitored at two week intervals until defined endpoints (liver metastasis or ascitis in 10 rats versus 10 controls. μCT had a 100% positive predictive value in the detection of orthotropic PDAC. Regression analysis showed a linear correlation between ex vivo and in vivo μCT tumor measurements. Longitudinal evaluation of tumor progression showed a reduction in tumor growth (P<0.05 at 8 weeks and a slightly prolonged survival (P=0.15 under gemcitabine treatment. In conclusion μCT appears to be a cost-effective mean for preclinical study of PDAC saving time, animals, while respecting animal welfare. It could be considered as an efficient tool in anticancer drug research and development.

  8. Experimental measurement of the correlation between CT number and heavy ion range

    Institute of Scientific and Technical Information of China (English)

    HE Peng-Bo; LI Qiang; LIU Xin-Guo; YE Fei; DAI Zhong-Ying

    2012-01-01

    For precision delivery of the Bragg peak of a heavy-ion beam to a target volume in ion beam therapy,it is necessary to know the tissue stopping power.A general approach to solve this problem in ion beam therapy is to convert X-ray CT (computed tomography) numbers into water-equivalent path length (WEPL) coefficients using a CT-WEPL calibration curve for all voxels traversed by the beam.This work aims at establishing a CT-WEPL coefficient calibration curve for the heavy ion therapy project at IMP,so as to compute the range of carbon ion beams in tissues easily according to the patient CT data.Several tissueequivalent materials wcrc applicd to measure their WEPL coefficients using a high-energy carbon ion beam in this work.A CT-WEPL calibration curve was obtained through fitting the measured data,which can be used directly for dose optimization and facilitates the design of patient treatment plans significantly at IMP.

  9. PET/CT in therapy evaluation of patients with lung cancer

    DEFF Research Database (Denmark)

    Langer, Natasha Hemicke; Christensen, Tine Nøhr; Langer, Seppo W

    2014-01-01

    FDG-PET/CT is a well documented and widespread used imaging modality for the diagnosis and staging of patient with lung cancer. FDG-PET/CT is increasingly used for the assessment of treatment effects during and after chemotherapy. However, PET is not an accepted surrogate end-point for assessment...... of response rate in clinical trials. The aim of this review is to present current evidence on the use of PET in response evaluation of patients with lung cancer and to introduce the pearls and pitfalls of the PET-technology relating to response assessment. Based on this and relating to validation criteria......, including stable technology, standardization, reproducibility and broad availability, the review discusses why, despite numerous studies on response assessment indicating a possible role for FDG-PET/CT, PET still has no place in guidelines relating to response evaluation in lung cancer....

  10. [Quantitative Evaluation of Metal Artifacts on CT Images on the Basis of Statistics of Extremes].

    Science.gov (United States)

    Kitaguchi, Shigetoshi; Imai, Kuniharu; Ueda, Suguru; Hashimoto, Naomi; Hattori, Shouta; Saika, Takahiro; Ono, Yoshifumi

    2016-05-01

    It is well-known that metal artifacts have a harmful effect on the image quality of computed tomography (CT) images. However, the physical property remains still unknown. In this study, we investigated the relationship between metal artifacts and tube currents using statistics of extremes. A commercially available phantom for measuring CT dose index 160 mm in diameter was prepared and a brass rod 13 mm in diameter was placed at the centerline of the phantom. This phantom was used as a target object to evaluate metal artifacts and was scanned using an area detector CT scanner with various tube currents under a constant tube voltage of 120 kV. Sixty parallel line segments with a length of 100 pixels were placed to cross metal artifacts on CT images and the largest difference between two adjacent CT values in each of 60 CT value profiles of these line segments was employed as a feature variable for measuring metal artifacts; these feature variables were analyzed on the basis of extreme value theory. The CT value variation induced by metal artifacts was statistically characterized by Gumbel distribution, which was one of the extreme value distributions; namely, metal artifacts have the same statistical characteristic as streak artifacts. Therefore, Gumbel evaluation method makes it possible to analyze not only streak artifacts but also metal artifacts. Furthermore, the location parameter in Gumbel distribution was shown to be in inverse proportion to the square root of a tube current. This result suggested that metal artifacts have the same dose dependence as image noises.

  11. Practical method of quantifying cerebral blood flow using arterial spin labeling. Numerical simulation and correlation of pulsed ASL and cold xenon-CT CBF

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Tokunori [Toshiba Corp., Otawara, Tochigi (Japan). Medical Systems R and D Center; Takahashi, Kiyohiko; Nozokido, Takeshi; Sato, Takaaki; Naito, Isao; Takatama, Shin [Geriatrics Research Inst. and Hospital, Gunma (Japan); Iwai, Tomoyuki [Suwa Central Hospital, Chino, Nagano (Japan)

    2002-07-01

    Currently arterial spin labeling (ASL) is not used in clinical practice even though various studies have been carried out on quantifying cerebral blood flow (CBF) by magnetic resonance (MR) perfusion imaging using ASL. In the following study, we evaluated the relationship between ASL signals and cerebral blood flow both numerically and experimentally. When evaluating the relationship numerically we used simulation based on the two-compartment model. We evaluated experimentally by using the correlation of pulsed ASL (PASL) signals with the CBF measured by cold xenon-CT (Xe-CT) in the human brain. Based on the results, we propose a practical linear scaling method for quantifying CBF values using a single TI pulsed ASL image. Numerical simulation using the two-compartment model, which was considered to model reality more closely than the conventional single-compartment model, showed that the ASL signal was correlated almost linearly in the CBF range (<100[ml/100 cc/min]). The ASL signal was also stronger in variations of model parameters, such as the relaxation time in extravascular space (T{sub 1e}), intravascular volume (CBV), and the brain-blood partition coefficient, than when the conventional single-compartment model was used. A linear correlation between the ASL signal and the absolute CBF value was also found in the PASL and Xe-CT experiments. This indicates that it may be possible to quantify CBF values using only a single TI pulsed ASL image. The proposed method requires reference CBF data (Xe-CT, SPECT, PET data or flow phantom data) or both a control image and conversion table obtained by simulation calculations. Although the ASL signals depend on the MRI hardware and imaging conditions, once the scaling coefficient K is calculated, the ASL signals can be converted to corresponding CBF values. Further studies are required in patients with ischemic conditions because the arterial transit delay time cannot be ignored in these patients. The proposed method can

  12. Implementation and evaluation of a protocol management system for automated review of CT protocols.

    Science.gov (United States)

    Grimes, Joshua; Leng, Shuai; Zhang, Yi; Vrieze, Thomas; McCollough, Cynthia

    2016-09-08

    Protocol review is important to decrease the risk of patient injury and increase the consistency of CT image quality. A large volume of CT protocols makes manual review labor-intensive, error-prone, and costly. To address these challenges, we have developed a software system for automatically managing and monitoring CT proto-cols on a frequent basis. This article describes our experiences in the implementation and evaluation of this protocol monitoring system. In particular, we discuss various strategies for addressing each of the steps in our protocol-monitoring workflow, which are: maintaining an accurate set of master protocols, retrieving protocols from the scanners, comparing scanner protocols to master protocols, reviewing flagged differences between the scanner and master protocols, and updating the scanner and/or master protocols. In our initial evaluation focusing only on abdo-men and pelvis protocols, we detected 309 modified protocols in a 24-week trial period. About one-quarter of these modified protocols were determined to contain inappropriate (i.e., erroneous) protocol parameter modifications that needed to be corrected on the scanner. The most frequently affected parameter was the series description, which was inappropriately modified 47 times. Two inappropriate modifications were made to the tube current, which is particularly important to flag as this parameter impacts both radiation dose and image quality. The CT protocol changes detected in this work provide strong motivation for the use of an automated CT protocol quality control system to ensure protocol accuracy and consistency.

  13. Usefulness of dynamic CT in the evaluation of percutaneous microwave coagulation therapy for liver cancer

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Naoki [Tottori Univ., Yonago (Japan). Faculty of Medicine

    1999-07-01

    This paper is concerned with effects of percutaneous microwave coagulation therapy (PMCT) and evaluation of PMCT by dynamic computed tomography (CT). Between January 1996 and March 1998, 23 patients with liver cancer were selected for this study. In 5 patients in the series, the extent of heating with irradiation at 60 Watts for 60 seconds was measured. In remaining 18 patients, PMCT was repeated till the hyperechogenic areas extended the whole target area on ultrasonography (US). Dynamic CT obtained one week after PMCT was compared with histological findings of the resected specimen that had been obtained 8 days after PMCT. The temperature rose over 60degC within 7.5 mm-area from the electrode. Each area coagulated by PMCT was shown as low density one both in early and delayed phase of dynamic CT. Accurate diagnoses whether undestroyed cancerous tissue was left or not were obtained by dynamic CT in 6 of 8 patients whose tumor was incompletely destroyed, and in all of 10 patients whose tumor was completely destroyed after PMCT. PMCT as a local treatment for liver cancer was considered to be a highly effective technique, because a certain area around punctured electrode fell into necrosis without exception. And dynamic CT was revealed to be a useful method for the patients with liver cancer to evaluate the effect of PMCT. (author)

  14. FDG-PET/CT response evaluation during EGFR-TKI treatment in patients with NSCLC

    Institute of Scientific and Technical Information of China (English)

    Matthijs; H; van; Gool; Tjeerd; S; Aukema; Koen; J; Hartemink; Renato; A; Valdés; Olmos; Houke; M; Klomp; Harm; van; Tinteren

    2014-01-01

    Over recent years,[18F]-fluorodeoxyglucose positron emission tomography acquired together with low dose computed tomography(FDG-PET/CT)has proven its role as a staging modality in patients with non-small cell lung cancer(NSCLC).The purpose of this review was to present the evidence to use FDG-PET/CT for response evaluation in patients with NSCLC,treated with epidermal growth factor receptor(EGFR)-tyrosine kinase inhibitors(TKI).All published articles from 1November 2003 to 1 November 2013 reporting on 18FFDG-PET response evaluation during EGFR-TKI treatment in patients with NSCLC were collected.In total 7studies,including data of 210 patients were eligible for analyses.Our report shows that FDG-PET/CT responseduring EGFR-TKI therapy has potential in targeted treatment for NSCLC.FDG-PET/CT response is associated with clinical and radiologic response and with survival.Furthermore FDG-PET/CT response monitoring can be performed as early as 1-2 wk after initiation of EGFR-TKI treatment.Patients with substantial decrease of metabolic activity during EGFR-TKI treatment will probably benefit from continued treatment.If metabolic response does not occur within the first weeks of EGFR-TKI treatment,patients may be spared(further)unnecessary toxicity of ineffective treatment.Refining FDG-PET response criteria may help the clinician to decide on continuation or discontinuation of targeted treatment.

  15. PET-CT in the evaluation of sarcomas of soft tissues; PET-CT en la evaluacion de sarcomas de tejidos blandos

    Energy Technology Data Exchange (ETDEWEB)

    Serna M, J.A.; Quiroz C, O.; Sanchez C, N.; Diaz V, G. [Hospital Angeles del Pedregal, Mexico D.F. (Mexico)

    2007-07-01

    {sup 18} F-FDG PET-CT is an image modality of great utility in the evaluation of primary or recurrent lesions of soft tissues. It is necessary to determine the cost-benefit of the different image modalities, although one waits that by means of a better diagnostic, statification and the determination of the grade of malignancy, the PET-CT nowadays can reduce the cost and the complications of the invasive diagnostic methods. (Author)

  16. Sensorineural hearing loss: there is no correlation with isolated dysplasia of the lateral semi-circular canal on temporal bone CT

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Tuvshinjargal, Dashjamts; Kamano, Hironori; Honda, Hiroshi (Dept. of Clinical Radiology, Graduate School of Medical Sciences, Kyushu Univ. Fukuoka (Japan)), email: tyoshiu@radiol.med.kyushu-u.ac.jp; Inoguchi, Takashi (Dept. of Otolaryngology, Kitakyushu Municipal Medical Center, Kitakyushu (Japan))

    2011-02-15

    Background: Inner ear malformations may cause sensorineural hearing loss (SNHL). However, the correlation between the small lateral semi-circular canal (LSCC) and SNHL is controversial. Purpose: To determine whether there is a correlation between the two using CT-based measurement. Material and Methods: We retrospectively reviewed the high-resolution CT images of the temporal bone obtained from consecutive patients. A total 136 ears of 68 patients (25 men and 43 women; age range 20-85 years, mean 49.8 years) were included in this study. Patients who were clinically suspected to have otosclerosis were also excluded. Two radiologists independently measured the width and cross-sectional area of the bony island of LSCC. We evaluated the correlation between LSCC bone island width or cross-sectional area and hearing level in all cases using Pearson correlation co-efficients. In addition, we compared hearing levels among the patient group with normal-sized LSCC (>=mean-SD), small LSCC (correlation was shown between LSCC bony island width or cross sectional area and hearing level (P>0.05). No significant difference in hearing levels were found among groups of the normal-sized, small and very small LSCC (P>0.05). Conclusion: We conclude that there is no correlation between isolated small LSCC and SNHL

  17. Correlation of VEGF with contrast enhancement on dual-phase dynamic helical CT in liver tumors: preliminary study.

    Science.gov (United States)

    Kwak, B. K.; Shim, H. J.; Park, U. S.; Lee, T. J.; Paeng, S. S.; Lee, C. J.; Lim, H. K.; Park, C. K.

    2001-01-01

    The purpose of this preliminary study is to elucidate that vascular endothelial growth factor (VEGF) influences contrast enhancement of hepatic tumors on computed tomography (CT). Fourteen patients with hepatic tumors (11 hepatocellular carcinomas; 3 metastatic cancers) underwent a dual-phase dynamic helical CT or computed tomographic hepatic arteriography. The attenuation of each mass was determined as hyperattenuation, isoattenuation or hypoattenuation with respect to the adjacent nontumorous parenchyma. Gun-needle biopsy was done for each tumor, and paraffin sections were immunostained with anti- VEGF antibody by the avidin-biotin-peroxidase complex method. The pathologic grade was made by intensity (1 +, 2+, 3+) and area (+/-, 1 +, 2+). The tumor ranged 2.0-14.0 cm in size (mean, 5.8 cm). In arterial phase, the intensity was not correlated with the degree of enhancement (p=0.086). However, the correlation between the attenuation value of hepatic arterial phase and the area of positive tumor cells was statistically significant (p=0.002). VEGF may be the factor that enhances the hepatic mass with water-soluble iodinated contrast agent in CT. PMID:11289406

  18. Recurrent pyogenic cholangitis: clinico-pathologic correlation of focal attenuation differences on multi-phasic spiral CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jun Yong; Han, Joon Koo; Kim, Tae Kyoung; Kim, Seog Joon; Kim, Hyun Bum; Choi, Byung Ihn [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-02-01

    To determine the clinical and the pathologic significance of the focal attenuation differences (FAD) and bile duct wall enhancement occurring in recurrent pyogenic cholangitis (RPC) and seen at multiphasic spiral CT. Among the multiphasic (non-contrast, arterial and portal or delayed phase) spiral CT findings of 60 consecutive patients, two types of FAD were noted during the non-contrast phase. These were Type A (iso) and Type B (low attenuation), and their distribution pattern (lobar versus patchy, multifocal) and the and the presence or absence of bile duct wall enhancement were recorded. The radiologic findings were correlated with the clinical and pathologic findings. Two types of FAD were noted in 40 of the 60 patients. Active in flammation was present in 19 of the 27 with Type-A and in ten of the 15 in whom the presence of RPC was pathologically proven. Ten of the 13 with Type-B FAD were in a subclinical state, and nine of the ten in whom RPC was pathologically proven had chronic inflammation. Among 20 patients who did not have FAD, RPC was subclinical in 18 and dormant in nine of the eleven in whom its presence was pathologically proven (p<0.001). Clinico-pathologic correlation with bile duct wall enhancement and the distribution pattern of FAD showed no statistical significance. The inflammatory activity of RPC can be predicted by analysis of the FAD seen at multiphasic spiral CT.

  19. Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ki Ho; Choo, Ki Seok [Pusan National University Hospital, Department of Radiology, Medical Institute, Pusan (Korea); Lim, Soo Jin [Kim Hae Joong Ang Hospital, Department of Cardiology, Kimhae (Korea); Lee, Hyoung Doo; Park, Ji Ae; Jo, Min Jung [Pusan National University Hospital, Department of Paediatrics, Pusan (Korea); Sung, Si Chan; Chang, Yun Hee [Pusan National University Hospital, Department of Thoracic and Cardiovascular Surgery, Pusan (Korea); Jeong, Dong Wook [Pusan National University Hospital, Department of Family Medicine, Pusan (Korea); Kim, Siho [Dong-A University Hospital, Department of Thoracic and Cardiovascular Surgery, Pusan (Korea)

    2009-09-15

    Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. To compare MDCT with echocardiography in the evaluation of TAPVC. Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. MDCT can facilitate the diagnosis of TAPVC in certain cases. (orig.)

  20. MR spectroscopy and micro-CT in evaluation of osteoporosis model in rabbits: comparison with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Li, Guan-wu; Tang, Guang-yu; Liu, Yong; Tang, Rong-biao; Peng, Yi-feng; Li, Wei [People' s Hospital of Tongji University, Department of Radiology, Shanghai (China)

    2012-04-15

    To explore the evidence of regular alteration of bone quality in osteoporosis dynamically examined by MRS and micro-CT, comparing with histopathology. Forty rabbits were allocated into two groups. Group A were used as sham. Group B underwent bilateral ovariectomy (OVX) combined with daily intramuscular methylprednisolone, underwent MR spectroscopy, micro-CT, and histopathology of L5 at 2, 4, 8, and 10 weeks after operation. Fat fraction as shown by MRS in Group B was significantly increased over the time course of osteoporosis development with significant difference between two groups at 4, 8, and 10 weeks after OVX. Continuous deterioration of cancellous bone architecture in Group B, was first detected at week4. FF value in group B correlated with micro-CT parameters. Marrow fat as measured by MR and CT was positively correlated with both the mean density and diameter of adipocytes (both of which increased over time). Marrow adipogenesis occurs in synchrony with deterioration of trabecular microarchitecture.MRS may be valuable to assess the pathophysiological changes of bone marrow in osteoporosis in early stage. (orig.)

  1. Correlation Evaluation on Small LTE Handsets

    DEFF Research Database (Denmark)

    Barrio, Samantha Caporal Del; Pedersen, Gert Frølund

    2012-01-01

    This paper presents measurements of the first MIMO handset on the market. It investigates the correlation coefficient computed from coaxial cable measurements and from optical fiber measurements. The results are compared and discussed. The question of the actual feasibility of low correlation...

  2. CT imaging vs. traditional radiographic imaging for evaluating Harris Lines in tibiae

    DEFF Research Database (Denmark)

    Primeau, Charlotte; Jakobsen, Lykke Schrøder; Lynnerup, Niels

    2016-01-01

    This paper is the first to systematically investigate computer tomography (CT) images vs. ordinary flat plane radiography for evaluating Harris Lines (HL) on tibiae. Harris Lines are traditionally investigated using radiographic images and recorded as either present or absent, or by counting...

  3. Differential Diagnoses of Solitary Pulmonary Nodules in Patients with an Extrathoracic Malignant Tumor:CT and Parthologic Correlations

    Institute of Scientific and Technical Information of China (English)

    Chengzhou Li; Xiangsheng Xiao; Shiyuan Liu; Huimin Li; Weihua Dong; Biao Ding; Qinghua Zhang

    2005-01-01

    OBJECTIVE To determine the possibility of definitive diagnosis for solitary pulmonary nodules in patients with a primary extrathoracic malignant neoplasm (ETM-SPN), and to further evaluate the value of CT for differential diagnosis in ETM-SPN by a multivariate retrospective study.METHODS Eighty-three patients with pathologically and clinically proven ETM-SPN with a diameter smaller than 3 cm were included in this study.The pathological characteristics of the SPN were correlated with those of the extrathoracic neoplasm, with the patient's age, gender, smoking history, disease-free time interval between the diagnosis of the extrathoracic malignancy and that of the lung lesion. In all 83 cases, CT scans were reviewed to confirm the solitary nature, size, and nodular morphology of the lung lesion.RESULTS Of all 83 cases, the mean age was (57.43±15.34) years. There were 51 males and 32 females, with the ratio of 1.59:1. The lesions included solitary metastasis in 43 cases, pulmonary malignant lesions in 33, and benign lesions in seven. Between the primary lung cancers and solitary metastasis groups, there was no significant difference in the gender ratio (1.20:1 vs 2.31:1, x2=0.0209, P>0.05), but there was a significant difference between the mean age (62.48±11.96 years vs 54.10±16.49 years, t=3.34, P0.05). Of 81cases who were followed-up, the mean time of the disease-free interval between extrapulmonary malignancy diagnosis and pulmonary lesion differentiation was 39.73± 6.29 months (range 0~300 months, median 20.00 months), whereas those in the primary lung cancer group and metastatic group were 65.62 ±13.45 months and 22.83 ±4.19 months respectively. This difference was significant between the two groups (Wilcoxon rank sum test, U=2.796, P0.05), without showing a statistically significant relevance between the pathologic patterns of extrapulmonary malignancy and characteristics of the lung nodules. Of all the 83 cases, the mean diameters were (2.77±1.25) cm

  4. Multidetector spiral CT arthrography of the shoulder. Clinical applications and limits, with MR arthrography and arthroscopic correlations.

    Science.gov (United States)

    Lecouvet, Frédéric E; Simoni, Paolo; Koutaïssoff, Sophie; Vande Berg, Bruno C; Malghem, Jacques; Dubuc, Jean-Emile

    2008-10-01

    Although MR imaging and MR arthrography are the first choice modalities for shoulder imaging, CT arthrography (CTA) may be used successfully to address many clinical questions. The advent of submillimeter multiple detector CT technology and subsequent excellent three-plane resolution has considerably increased the quality of CTA examinations and has propelled this technique to the forefront in a growing number of indications. The combined use of iodinated contrast material for fluoroscopic confirmation of the articular position of the needle before injection of gadolinium chelates for MR arthrography offers the unique opportunity to compare CTA and MRA findings in carefully selected cases. This paper illustrates capabilities and limits of CTA for the study of rotator cuff tears, shoulder instability, cartilage lesions, anatomical variants and abnormalities of the glenoid labrum, with correlations to MR arthrography and surgical findings.

  5. Dual energy CT for the assessment of lung perfusion-Correlation to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Sven F.; Becker, Christoph R. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Hacker, Marcus [Department of Nuclear Medicine, Ludwig-Maximilians-University of Munich (Germany); Nikolaou, Konstantin; Reiser, Maximilian F. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany); Johnson, Thorsten R.C. [Department of Clinical Radiology, Ludwig-Maximilians-University of Munich (Germany)], E-mail: thorsten.johnson@med.uni-muenchen.de

    2008-12-15

    Purpose of this study was to determine the diagnostic value of dual energy CT in the assessment of pulmonary perfusion with reference to pulmonary perfusion scintigraphy. Thirteen patients received both dual energy CT (DECT) angiography (Somatom Definition, Siemens) and ventilation/perfusion scintigraphy. Median time between scans was 3 days (range, 0-90). DECT perfusion maps were generated based on the spectral properties of iodine. Two blinded observes assessed DECT angiograms, perfusion maps and scintigrams for presence and location of perfusion defects. The results were compared by patient and by segment, and diagnostic accuracy of DECT perfusion imaging was calculated regarding scintigraphy as standard of reference. Diagnostic accuracy per patient showed 75% sensitivity, 80% specificity and a negative predictive value of 66%. Sensitivity per segment amounted to 83% with 99% specificity, with 93% negative predictive value. Peripheral parts of the lungs were not completely covered by the 80 kVp detector in 85% of patients. CTA identified corresponding emboli in 66% of patients with concordant perfusion defects in DECT and scintigraphy. Dual energy CT perfusion imaging is able to display pulmonary perfusion defects with good agreement to scintigraphic findings. DECT can provide a pulmonary CT angiogram, high-resolution morphology of the lung parenchyma and perfusion information in one single exam.

  6. Inflicted T12 fracture-dislocation: CT/MRI correlation and mechanistic implications

    Energy Technology Data Exchange (ETDEWEB)

    Tran, Brandon [Brigham and Women' s Hospital, Section of Neuroradiology, Department of Radiology, Boston, MA (United States); Silvera, Michelle [Children' s Hospital Boston, Division of Neuroradiology, Department of Radiology, Boston, MA (United States); Newton, Alice [Children' s Hospital Boston, Division of General Pediatrics, Boston, MA (United States); Kleinman, Paul K. [Children' s Hospital Boston, Department of Radiology, Boston, MA (United States)

    2007-11-15

    We describe the CT and MRI findings of a thoracolumbar neurocentral synchondrosis fracture-dislocation in an abused infant. The morphologic features of this classically described fracture, and the associated cervical and sacral spine injuries displayed on cross-sectional imaging, provide compelling evidence for a mechanism of massive hyperflexion and axial spinal loading. (orig.)

  7. Bilateral internal carotid agenesis: value of CT angiography and correlation to embryogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Pilleul, F.; Rouviere, O. [Dept. of Radiology, Hopital Edouard Herriot, Lyon (France); Guibaud, L.; Pracros, J.P. [Dept. of Pediatric Imaging, Hopital Debrousse, Lyon (France); Badinand, N. [Dept. of Pediatric Neurology, Hopital Debrousse, Lyon (France)

    2001-05-01

    Bilateral internal carotid artery agenesis is an uncommon disease, difficult to differentiate from bilateral carotid artery thrombosis. A few case reports have described the contribution of conventional angiogram to make the diagnosis and recognize the anatomic details of this rare malformation. Advantages of CT angiography as a non-invasive radiologic tool are discussed in this case report. (orig.)

  8. Toxoplasma encephalitis in Haitian adults with acquired immunodeficiency syndrome: a clinical-pathologic-CT correlation

    Energy Technology Data Exchange (ETDEWEB)

    Post, M.J.D.; Chan, J.C.; Hensley, G.T.; Hoffman, T.A.; Moskowitz, L.B.; Lippmann, S.

    1983-05-01

    The clinical data, histologic findings, and computed tomographic (CT) abnormalities in eight adult Haitians with toxoplasma encephalitis were analyzed retrospectively. Diagnosis was established by identification of Toxoplasma gondii on autopsy in five and brain biopsy in three specimens and subsequently confirmed by the immunoperoxidase method. All these patiens, six of whom had been in the United States for 24 months or less, had severe idiopathic immunodeficiency syndrome. All were lymphopenic and six were on treatment for tuberculosis when the toxoplasma encephalitis developed. All patients were studied with CT when they developed an altered mental status and fever associated with seizures and/or focal neurologic deficits. Scans before treatment showed multiple intraparenchymal lesions in seven and a single lesion in the thalamus in one. Ring and/or nodular enhancement of the lesions was found in six and hypodense areas in two. Progressions of abnormalities occurred on serial studies. These CT findings that were best shown on axial and coronal thin-section double-dose contrast studies were useful but not diagnostically pathognomonic. In patients with similar clinical presentation CT is recommended to identify focal areas of involvement and to guide brain biopsy or excision so that prompt medical thereapy of this often lethal infection can be instituted.

  9. Evaluation of GMI and PMI diffeomorphic-based demons algorithms for aligning PET and CT Images.

    Science.gov (United States)

    Yang, Juan; Wang, Hongjun; Zhang, You; Yin, Yong

    2015-07-08

    Fusion of anatomic information in computed tomography (CT) and functional information in 18F-FDG positron emission tomography (PET) is crucial for accurate differentiation of tumor from benign masses, designing radiotherapy treatment plan and staging of cancer. Although current PET and CT images can be acquired from combined 18F-FDG PET/CT scanner, the two acquisitions are scanned separately and take a long time, which may induce potential positional errors in global and local caused by respiratory motion or organ peristalsis. So registration (alignment) of whole-body PET and CT images is a prerequisite for their meaningful fusion. The purpose of this study was to assess the performance of two multimodal registration algorithms for aligning PET and CT images. The proposed gradient of mutual information (GMI)-based demons algorithm, which incorporated the GMI between two images as an external force to facilitate the alignment, was compared with the point-wise mutual information (PMI) diffeomorphic-based demons algorithm whose external force was modified by replacing the image intensity difference in diffeomorphic demons algorithm with the PMI to make it appropriate for multimodal image registration. Eight patients with esophageal cancer(s) were enrolled in this IRB-approved study. Whole-body PET and CT images were acquired from a combined 18F-FDG PET/CT scanner for each patient. The modified Hausdorff distance (d(MH)) was used to evaluate the registration accuracy of the two algorithms. Of all patients, the mean values and standard deviations (SDs) of d(MH) were 6.65 (± 1.90) voxels and 6.01 (± 1.90) after the GMI-based demons and the PMI diffeomorphic-based demons registration algorithms respectively. Preliminary results on oncological patients showed that the respiratory motion and organ peristalsis in PET/CT esophageal images could not be neglected, although a combined 18F-FDG PET/CT scanner was used for image acquisition. The PMI diffeomorphic-based demons

  10. Angiomyolipoma (AML) without visible fat: Ultrasound, CT and MR imaging features with pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Hakim, Shaheed W.; Flood, Trevor A. [The Ottawa Hospital, University of Ottawa, Department of Anatomical Pathology, Ottawa, Ontario (Canada); Schieda, Nicola; Hodgdon, Taryn; McInnes, Matthew D.F.; Dilauro, Marc [The Ottawa Hospital, University of Ottawa, Department of Medical Imaging, Ottawa, Ontario (Canada)

    2016-02-15

    To compare imaging findings with histopathology in AML without visible fat (AML{sub wvf}). With IRB approval, we identified 18 AML{sub wvf} that underwent CT between 2002-2014. A radiologist measured NECT-attenuation, corticomedullary (CM) and nephrographic (NG) enhancement, echogenicity relative to renal cortex (RC) (N = 5), T2W (T2{sub AML}/T2{sub RC}) signal-intensity (SI), and chemical-shift SI ([SI{sub IN-PHASE} - SI{sub OPPOSED-PHASE}]/SI{sub IN-PHASE}) indices (N = 6). A pathologist re-evaluated 15/18 AML{sub wvf} for 1) < or > 25 % adipocytes/high-power-field (HPF), 2) ''many or few'' blood vessels. Comparisons were performed using chi-square and independent t-tests. 73.3 %(11/15) of AML{sub wvf} had <25 % adipocytes/HPF and 86.7 %(13/15) had ''many'' blood vessels. NECT-attenuation was 41.8(±6.9) HU. 61.1 %(11/18) of AML{sub wvf} were hyper-attenuating and 38.9 %(7/18) iso-attenuating; attenuation was associated with %-adipocytes/HPF, (p = 0.01). CM/NG enhancement were 63.3(±20.8)/51.7(±15.5) HU. 72.2 %(13/18) of AML{sub wvf} had wash-out enhancement, with no association with amount of blood vessels at pathology, (p = 0.68). No difference in echogenicity was noted by histology (p > 0.05). All AML{sub wvf} were T2-hypointense (SI ratio = 0.61 [±0.1]). 2/6 AML{sub wvf} showed SI drop on chemical-shift MRI; both were iso-attenuating and were associated with >25 % adipocytes/HPF (p = 0.04). AML{sub wvf} are typically T2-hypointense and hyper-attenuating with wash-out enhancement due to abundant smooth muscle and vessels respectively. Iso-attenuating AML{sub wvf} with microscopic fat on MRI contain more adipocytes/HPF. (orig.)

  11. Cone-Beam Computed Tomography Correlates with Conventional Helical Computed Tomography in Evaluation of Lipiodol Accumulation in HCC after Chemoembolization.

    Directory of Open Access Journals (Sweden)

    Toru Ishikawa

    Full Text Available The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU, can predict tumor response. Here we investigate whether cone-beam CT (CBCT can also be used to predict tumor response, providing the benefit of being able to optimize the patient's treatment plan intra-procedurally.A total of 82 HCC nodules (82 patients, ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values.The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001. The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001 for the left lobe and 0.926 (p<0.001 for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU.CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization.

  12. Cone-Beam Computed Tomography Correlates with Conventional Helical Computed Tomography in Evaluation of Lipiodol Accumulation in HCC after Chemoembolization

    Science.gov (United States)

    Ishikawa, Toru; Abe, Satoshi; Hoshii, Asami; Yamada, Yumi; Iiduka, Akihiko; Nemoto, Takeo; Takeda, Keiko; Yoshida, Toshiaki

    2016-01-01

    Background & Aims The amount of drug-loaded lipiodol in an HCC tumor post-transarterial chemoembolization (TACE) correlates with the risk of local tumor recurrence. Lipiodol enhancement of a tumor on conventional CT, measured in Hounsfield units (HU), can predict tumor response. Here we investigate whether cone-beam CT (CBCT) can also be used to predict tumor response, providing the benefit of being able to optimize the patient’s treatment plan intra-procedurally. Methods A total of 82 HCC nodules (82 patients), ≤5 cm in diameter, were treated with balloon-occluded TACE using miriplatin between December 2013 and November 2014. For each patient, both CBCT and conventional CT images were obtained post-TACE. The degree of correlation between CBCT and conventional CT was determined by comparing identical regions of interest for each imaging modality using pixel values. Results The pixel values from conventional CT and CBCT were highly correlated, with a Pearson correlation coefficient of 0.912 (p<0.001). The location of the nodules within the liver did not affect the results; the correlation coefficient was 0.891 (p<0.001) for the left lobe and 0.926 (p<0.001) for the right lobe. The mean pixel value for conventional CT was 439 ± 279 HU, and the mean pixel value for CBCT was 416 ± 311 HU. Conclusions CBCT may be used as a substitute for conventional CT to quantitatively evaluate the amount of drug-loaded lipiodol within an HCC nodule and, hence, the efficacy of TACE treatment. The major benefit of using CBCT is the ability to predict the likelihood of local recurrence intra-procedurally, enabling subsequent treatment optimization. PMID:26752696

  13. Multimodality thoracic imaging of juvenile systemic sclerosis: emphasis on clinical correlation and high-resolution CT of pulmonary fibrosis.

    Science.gov (United States)

    Valeur, Natalie S; Stevens, Anne M; Ferguson, Mark R; Effmann, Eric L; Iyer, Ramesh S

    2015-02-01

    OBJECTIVE. Juvenile systemic sclerosis is a rare multisystem autoimmune disorder characterized by vasculopathy and multiorgan fibrosis. Cardiopulmonary complications are the leading cause of morbidity and mortality. Although pulmonary fibrosis is the complication that is most common and well described, cardiovascular and esophageal involvement may also be observed. In this article, common thoracic findings in juvenile systemic sclerosis will be discussed. We will focus on chest CT, including CT findings of pulmonary fibrosis and associated grading methods, as well as cardiac MRI and esophageal imaging. CONCLUSION. Radiologists play a pivotal role in the initial diagnosis and follow-up evaluation of pediatric patients with systemic sclerosis. Treatment decisions and prognostic assessment are directly related to imaging findings along with clinical evaluation.

  14. SU-E-J-226: Propagation of Pancreas Target Contours On Respiratory Correlated CT Images Using Deformable Image Registration

    Energy Technology Data Exchange (ETDEWEB)

    Liu, F [Rhode Island Hospital / Brown University, Providence, RI (United States); Yorke, E; Mageras, G; Goodman, K [Memorial Sloan-Kettering Cancer Center, NY, NY (United States)

    2014-06-01

    Purpose: Respiratory Correlated CT (RCCT) scans to assess intra-fraction motion among pancreatic cancer patients undergoing radiotherapy allow for dose sparing of normal tissues, in particular for the duodenum. Contour propagation of the gross tumor volume (GTV) from one reference respiratory phase to 9 other phases is time consuming. Deformable image registration (DIR) has been successfully used for high contrast disease sites but lower contrast for pancreatic tumors may compromise accuracy. This study evaluates the accuracy of Fast Free Form (FFF) registration-based contour propagation of the GTV on RCCT scans of pancreas cancer patients. Methods: Twenty-four pancreatic cancer patients were retrospectively studied; 20 had tumors in the pancreatic head/neck, 4 in the body/tail. Patients were simulated with RCCT and images were sorted into 10 respiratory phases. A radiation oncologist manually delineated the GTV for 5 phases (0%, 30%, 50%, 70% and 90%). The FFF algorithm was used to map deformations between the EE (50%) phase and each of the other 4 phases. The resultant deformation fields served to propagate GTV contours from EE to the other phases. The Dice Similarity Coefficient (DSC), which measures agreement between the DIR-propagated and manually-delineated GTVs, was used to quantitatively examine DIR accuracy. Results: Average DSC over all scans and patients is 0.82 and standard deviation is 0.09 (DSC range 0.97–0.57). For GTV volumes above and below the median volume of 20.2 cc, a Wilcoxon rank-sum test shows significantly different DSC (p=0.0000002). For the GTVs above the median volume, average +/− SD is 0.85 +/− 0.07; and for the GTVs below, the average +/− SD is 0.75 +/−0.08. Conclusion: For pancreatic tumors, the FFF DIR algorithm accurately propagated the GTV between the images in different phases of RCCT, with improved performance for larger tumors.

  15. Internal Hernias in the Era of Multidetector CT: Correlation of Imaging and Surgical Findings.

    Science.gov (United States)

    Doishita, Satoshi; Takeshita, Tohru; Uchima, Yasutake; Kawasaki, Masayasu; Shimono, Taro; Yamashita, Akiyoshi; Sugimoto, Michiko; Ninoi, Teruhisa; Shima, Hideki; Miki, Yukio

    2016-01-01

    Clinical diagnosis of internal hernias is challenging because of their nonspecific signs and symptoms. Many types of internal hernias have been defined: paraduodenal, small bowel mesentery-related, greater omentum-related, lesser sac, transverse mesocolon-related, pericecal, sigmoid mesocolon-related, falciform ligament, pelvic internal, and Roux-en-Y anastomosis-related. An internal hernia is a surgical emergency that can develop into intestinal strangulation and ischemia. Accurate preoperative diagnosis is crucial for appropriate management. Multidetector computed tomography (CT), with its thin-section axial images, high-quality multiplanar reformations, and three-dimensional images, currently plays an essential role in preoperative diagnosis of internal hernias. The diagnostic approach to internal hernias at multidetector CT includes detecting an intestinal closed loop, identifying the hernia orifice, and analyzing abnormal displacement of surrounding structures and key vessels around the hernia orifice and hernia sac. At each step, multidetector CT can depict pathognomonic findings. A saclike appearance suggests an intestinal closed loop in several types of internal hernias. Convergence, engorgement, and twisting of mesenteric vessels in the hernia orifice can be seen clearly at multidetector CT, especially with use of multiplanar reformations. For definitive diagnosis of an internal hernia, analysis of displacement of anatomic landmarks around the hernia orifice is particularly important, and thin-section images provide the required information. Detailed knowledge of the anatomy, etiology, and imaging landmarks of the various hernia types is also necessary. Familiarity with the appearances of internal hernias at multidetector CT allows accurate and specific preoperative diagnosis. (©)RSNA, 2015.

  16. The correlation between the paired inspiratory and expiratory three-dimensional quantitative CT and pulmonary function test in chronic obstructive pulmonary disease

    Institute of Scientific and Technical Information of China (English)

    隋昕

    2013-01-01

    Objective To investigate the correlation between the paired inspiratory and expiratory quantitative CT and pulmonary function tests (PFTs) in patients with chronic obstructive pulmonary disease (COPD) .Methods A total of 84 patients with COPD were enrolled.For each

  17. Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T

    Energy Technology Data Exchange (ETDEWEB)

    Simgen, Andreas; Ley, Desiree; Muehl-Benninghaus, Ruben; Koerner, Heiko; Reith, Wolfgang; Yilmaz, Umut [Saarland University Hospital, Department of Neuroradiology, Homburg, Saar (Germany); Roth, Christian [Clinic Bremen-Mitte, Department of Neuroradiology, Bremen (Germany); Cattaneo, Giorgio Franco Maria [Acandis GmbH, Pforzheim (Germany); Mueller, Andreas [Saarland University Hospital, Department of Experimental Surgery, Homburg, Saar (Germany); Kim, Yoo-Jin [Saarland University Hospital, Department of Pathology, Homburg, Saar (Germany); Scheller, Bruno [Saarland University Hospital, Department of Cardiology, Homburg, Saar (Germany)

    2016-10-15

    Flow diverters are increasingly being used to treat intracranial aneurysms. This study evaluates occurring complications of flow-diverting devices in the treatment of experimental aneurysms, involving the use of micro-CT and small animal MRI at 9.4 T, in correlation to angiographic and histological findings. We previously published two preclinical studies, in which we assessed two different flow diverters in the treatment of elastase-induced aneurysms. Devices have been implanted across the aneurysm neck as well as in the abdominal aorta. From these studies, a total of 65 devices (prototype FD (n = 30) and Derivo embolization device (n = 35)) additionally underwent micro-CT and MRI after angiographic follow-up and before being histologically examined. The different architectures of both devices were precisely comparable due to high-resolution micro-CT imaging. Micro-CT revealed wire fractures in nine cases (30 %) only with the prototype FD. In three cases (10 %), severe wire fractures correlated with an in-stent stenosis due to intimal hyperplasia. Other complications, like distal stent occlusions and post-stent stenosis, were seen in both groups and verified with both imaging techniques. Osseous metaplasia were correlated to calcifications seen with micro-CT. MRI enabled visualization of the position of the implanted devices relative to the aneurysm and revealed incomplete aneurysm neck coverage with the prototype FD in two cases (6.7 %). Micro-CT and 9.4-T MRI are valid to discover and understand occurring complications of flow diverters in the preclinical phase and can serve as evaluation tools to minimize complication rates of endovascular devices in the future. (orig.)

  18. Utility of quantitative FDG-PET/CT for the detection of bone marrow involvement in follicular lymphoma: a histopathological correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A.; Kwee, Thomas C.; Nievelstein, Rutger A.J. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Fijnheer, Rob [Meander Medical Center, Department of Hematology, Amersfoort (Netherlands); Dubois, Stefan V. [Meander Medical Center, Department of Pathology, Amersfoort (Netherlands); Blase, Peter E.; Klerk, John M.H. de [Meander Medical Center, Department of Nuclear Medicine, Amersfoort (Netherlands)

    2014-09-15

    To determine the value of visual and quantitative {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone marrow involvement in follicular lymphoma, using direct histopathological examination at the right posterior iliac crest as reference standard. This retrospective study included 22 patients with newly diagnosed follicular lymphoma who had undergone FDG-PET/CT before BMB of the right posterior iliac crest. FDG-PET/CT images were visually evaluated for bone marrow involvement in the right posterior iliac crest. Volumes of interest were placed in the right posterior iliac crest to calculate the 3D partial volume corrected mean standardized uptake value (cSUV{sub mean}), maximum standardized uptake value (SUV{sub max}) and peak standardized uptake value (SUV{sub peak}). Sensitivity and specificity of visual FDG-PET/CT analysis for the detection of bone marrow involvement in the right posterior iliac crest were 0.0 % (95 % confidence interval (CI): 0-32.4 %) and 100 % (95 % CI: 78.5-100 %), respectively. Areas under the receiver-operating characteristic curve of cSUV{sub mean}, SUV{sub max} and SUV{sub peak} for the detection of bone marrow involvement in the right posterior iliac crest were 0.85 (95 % CI: 0.63-0.96), 0.89 (95 % CI: 0.68-0.98) and 0.87 (95 % CI: 0.65-0.97), respectively. Optimal cutoff values for cSUV{sub mean}, SUV{sub max} and SUV{sub peak} were 1.3, 2.1 and 1.7, and yielded sensitivity and specificity combinations of 75.0 % and 85.7 %, 87.5 % and 85.7 % and 87.5 % and 85.7 %, respectively. This histopathological correlation study shows that, unlike visual interpretation of FDG-PET/CT images, quantitative FDG-PET/CT analysis may be beneficial in diagnosing bone marrow involvement by follicular lymphoma. (orig.)

  19. The importance of PET/CT in the evaluation of patients with Ewing tumors

    Energy Technology Data Exchange (ETDEWEB)

    Guimaraes, Julio Brandao; Rigo, Leticia; Lewin, Fabio; Emerick, Andre, E-mail: juliobrandaoguimaraes@hotmail.com [Hospital Sao Jose-Beneficincia Portuguesa de Sao Paulo, SP (Brazil)

    2015-05-15

    The effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging. (author)

  20. 3D-CT vascular setting protocol using computer graphics for the evaluation of maxillofacial lesions

    Directory of Open Access Journals (Sweden)

    CAVALCANTI Marcelo de Gusmão Paraiso

    2001-01-01

    Full Text Available In this paper we present the aspect of a mandibular giant cell granuloma in spiral computed tomography-based three-dimensional (3D-CT reconstructed images using computer graphics, and demonstrate the importance of the vascular protocol in permitting better diagnosis, visualization and determination of the dimensions of the lesion. We analyzed 21 patients with maxillofacial lesions of neoplastic and proliferative origins. Two oral and maxillofacial radiologists analyzed the images. The usefulness of interactive 3D images reconstructed by means of computer graphics, especially using a vascular setting protocol for qualitative and quantitative analyses for the diagnosis, determination of the extent of lesions, treatment planning and follow-up, was demonstrated. The technique is an important adjunct to the evaluation of lesions in relation to axial CT slices and 3D-CT bone images.

  1. The importance of PET/CT in the evaluation of patients with Ewing tumors

    Directory of Open Access Journals (Sweden)

    Júlio Brandão Guimarães

    2015-06-01

    Full Text Available Abstract The effective evaluation for the treatment of patients with Ewing tumors depends on the accuracy in the determination of the primary tumor extent and the presence of metastatic disease. Currently, no universally accepted staging system is available to assess Ewing tumors. The present study aimed at discussing the use of PET/CT as a tool for staging, restaging and assessment of therapeutic response in patients with Ewing tumors. In spite of some limitations of PET/CT as compared with anatomical imaging methods, its relevance in the assessment of these patients is related to the capacity of the method to provide further physiological information, which often generates important clinical implications. Currently, the assessment of patients with Ewing tumor should comprise a study with PET/CT combined with other anatomical imaging modalities, such as radiography, computed tomography and magnetic resonance imaging.

  2. Evaluation of a low-dose CT protocol with oral contrast for assessment of acute appendicitis.

    Science.gov (United States)

    Platon, Alexandra; Jlassi, Helmi; Rutschmann, Olivier T; Becker, Christoph D; Verdun, Francis R; Gervaz, Pascal; Poletti, Pierre-Alexandre

    2009-02-01

    The aim of this study was to evaluate a low-dose CT with oral contrast medium (LDCT) for the diagnosis of acute appendicitis and compare its performance with standard-dose i.v. contrast-enhanced CT (standard CT) according to patients' BMIs. Eighty-six consecutive patients admitted with suspicion of acute appendicitis underwent LDCT (30 mAs), followed by standard CT (180 mAs). Both examinations were reviewed by two experienced radiologists for direct and indirect signs of appendicitis. Clinical and surgical follow-up was considered as the reference standard. Appendicitis was confirmed by surgery in 37 (43%) of the 86 patients. Twenty-nine (34%) patients eventually had an alternative discharge diagnosis to explain their abdominal pain. Clinical and biological follow-up was uneventful in 20 (23%) patients. LDCT and standard CT had the same sensitivity (100%, 33/33) and specificity (98%, 45/46) to diagnose appendicitis in patients with a body mass index (BMI) >or= 18.5. In slim patients (BMIor= 18.5.

  3. Performance evaluation of Biograph PET/CT system based on Monte Carlo simulation

    Science.gov (United States)

    Wang, Bing; Gao, Fei; Liu, Hua-Feng

    2010-10-01

    Combined lutetium oxyorthosilicate (LSO) Biograph PET/CT is developed by Siemens Company and has been introduced into medical practice. There is no septa between the scintillator rings, the acquisition mode is full 3D mode. The PET components incorporate three rings of 48 detector blocks which comprises a 13×13 matrix of 4×4×20mm3 elements. The patient aperture is 70cm, the transversal field of view (FOV) is 58.5cm, and the axial field of view is 16.2cm. The CT components adopt 16 slices spiral CT scanner. The physical performance of this PET/CT scanner has been evaluated using Monte Carlo simulation method according to latest NEMA NU 2-2007 standard and the results have been compared with real experiment results. For PET part, in the center FOV the average transversal resolution is 3.67mm, the average axial resolution is 3.94mm, and the 3D-reconstructed scatter fraction is 31.7%. The sensitivities of the PET scanner are 4.21kcps/MBq and 4.26kcps/MBq at 0cm and 10cm off the center of the transversal FOV. The peak NEC is 95.6kcps at a concentration of 39.2kBq/ml. The spatial resolution of CT part is up to 1.12mm at 10mm off the center. The errors between simulated and real results are permitted.

  4. Aortic Stenosis: Evaluation with Multidetector CT Angiography and MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Eun Ju; Choi, Sang Il; Lim, Cheong; Park, Kye Hyun; Chang, Hyuk Jae; Choi, Dong Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of); Kim, Dong Hun [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Lee, Whal; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of)

    2008-10-15

    Aortic valvular stenosis (AS) is the most common valve disease which results in the need for a valve replacement. Although a Doppler echocardiography is the current reference imaging method, the multidetector computerized tomography (MDCT) and magnetic resonance imaging (MRI) have recently emerged as a promising method for noninvasive valve imaging. In this study, we briefly describe the usefulness and comparative merits of the MDCT and MRI for the evaluation of AS in terms of valvular morphology (as the causes of AS), quantification of aortic valve area, pressure gradient of flow (for assessment severity of AS), and the evaluation of the ascending aorta and cardiac function (as the secondary effects of AS). The familiarity with the MDCT and MRI features of AS is considered to be helpful for the accurate diagnosis and proper management of patients with a poor acoustic window.

  5. Comparative evaluation of plain films, ultrasound and CT in the diagnosis of intestinal obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Suri, S.; Gupta, S.; Sudhakar, P.J.; Venkataramu, N.K.; Sood, B. [Postgraduate Inst. of Medical Education and Research, Chandigarh (India). Dept. of Radiodiagnosis; Wig, J.D. [Postgraduate Inst. of Medical Education and Research, Chandigarh (India). Dept. of Surgery

    1999-07-01

    Background: There are limited studies in the literature comparing plain radiography, US and CT in the evaluation of intestinal obstruction. We carried out this prospective study to compare the relative efficacies of these three imaging techniques in patients with intestinal obstruction. Material and methods: Thirty-two patients presenting with clinical suspicion of intestinal obstruction were subjected to plain radiography, US and CT and the findings were compared with reference to the presence or absence of obstruction, the level of obstruction and the cause of obstruction. The final diagnosis was obtained by surgery (n=25), or by contrast studies and/or clinical follow-up in those who were treated conservatively (n=7). Results: Out of 32 patients, 30 had mechanical intestinal obstruction (22 had small bowel obstruction and 8 had large bowel obstruction). Of the remaining 2 patients, 1 had adynamic ileus and the other had a mesenteric cyst. CT had high sensitivity (93%), specificity (100%) and accuracy (94%) in diagnosing the presence of obstruction. The comparable sensitivity, specificity and accuracy were, respectively, 83%, 100% and 84% for US and 77%, 50% and 75% for plain radiography. The level of obstruction was correctly predicted in 93% on CT, in 70% on US and in 60% on plain films. CT was superior (87%) to both US (23%) and plain radiography (7%) in determining the aetiology of obstruction. Conclusion: CT is a highly accurate method in the evaluation of intestinal obstruction especially for determining the level and cause of obstruction and should be the technique of choice when clinical or plain radiographic findings are equivocal. (orig.)

  6. Relationship between lower third molar and mandibular canal; Preoperative evaluation using CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Itou, Masaki; Miyagishima, Toshio; Onizuka, Hiroyuki (Fujieda City Shida General Hospital, Shizuoka (Japan)); Takagi, Norio

    1994-01-01

    The mandibular canal is often closely related to the lower third molars. During the surgical removal of the third molar, the inferior alveolar nerve in the canal is sometimes damaged leading to impaired sensation in the lower lip. This is one of the most unpleasant postoperative complications. The buccolingual relationship between the lower third molar and the mandibular canal cannot be diagnosed by ortho-pantomography although preoperative evaluation must be carried out radiologically. In present study, the relationship was determined by using CT scan. Forty-seven lower third molars of 35 patients were evaluated preoperatively by CT scan. The mandibular canal of all cases overlapped with the third molar on ortho-pantomography. CT scan was taken in two ways. The first was the Tragion-Menton plane which was nearly parallel to the canal at the apex of the third molar. The second was the plane of the axis of the third molar. Axial CT scan was taken when the third molar erupted horizontally, and coronal CT scan was done when the molar erupted vertically. CT scan examination exactly revealed the position of the mandibular canal in relation to the root of the third molar. The canal was located buccally to the roots in 55 percent of cases, apicobuccally in 6 percent, apically in 23 percent, apicolingually in 6 percent, lingually in 2 percent, and between roots in 6 percent. The results of the present study were consistent with previous reports. In 12 cases, the inferior alveolar neurovascular bundle was visible during operation. It was visible in only 2 of 22 cases when the canal was located buccally. It was visible, on the other hand, in all cases in which the canal was located apicolingually, lingually, and between roots. It also tended to be visible when the canal overlapped more strongly with the third molar on preoperative ortho-pantomography. (author).

  7. Value of oral effervescent powder administration for multidetector CT evaluation of esophageal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ringe, Kristina I., E-mail: ringe.kristina@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Meyer, Simone, E-mail: Meyer.simone.rad@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Ringe, Bastian P., E-mail: Ringe.bastian@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Winkler, Michael, E-mail: Winkler.michael@mh-hannover.de [Department of General, Visceral and Transplantation Surgery, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Wacker, Frank, E-mail: Wacker.frank@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany); Raatschen, Hans-Juergen, E-mail: Raatschen.hans-juergen@mh-hannover.de [Department of Diagnostic and Interventional Radiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625 Hannover (Germany)

    2015-02-15

    Highlights: • Oral effervescent powder improves esophageal distension and wall assessment at CT. • This technique improves detection and T staging of esophageal cancer at CT. • It can be easily adopted in clinical routine in patients with esophageal pathology. - Abstract: Purpose: To assess the value of oral effervescent powder (EP) for evaluation of esophageal distension, and for detection and staging of esophageal cancer with contrast-enhanced CT. Materials and methods: 84 patients without esophageal pathology and 52 patients with histological confirmed diagnosis of esophageal cancer were included in this prospective IRB-approved study. Half of the patients in both groups received EP prior to CT. Esophageal distension was assessed by planimetry of the inner (IA) and outer area (OA). Two blinded readers evaluated the datasets separately with regard to diagnosis of esophageal cancer (yes/no) and staging (T0-T4), if applicable. Distension results were compared (t-Test). In patients with cancer sensitivity, specificity, NPV and PPV were calculated. CT staging results were compared to histopathology (Cohen-k). Results: IA and IA/OA were significantly larger after EP as compared to the group without EP (p < 0.05). Sensitivity, specificity, NPV and PPV for cancer detection cancer were as follows: 78%/78%, 98%/98%, 95%/95%, 87%/87% with EP; 60%/68%, 98%/98%, 94%/94%, 80%/83% without EP. Staging with EP was good (k = 0.84/0.67) and moderate without EP (k = 0.58/0.59). Conclusions: Administration of EP prior to CT results in good distension of the esophagus, and improves detection and staging of esophageal cancer, as compared to control studies without EP.

  8. SU-E-J-35: Clinical Performance Evaluation of a Phase II Proton CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Mandapaka, A; Ghebremedhin, A; Farley, D; Giacometti, V; Vence, N; Bashkirov, V; Patyal, B; Schulte, R [Loma Linda UniversityMedical Center, Loma Linda, CA (United States); Plautz, T; Zatserklyaniy, A; Johnson, R; Sadrozinski, H [University of California Santa Cruz, Santa Cruz, CA (United States)

    2014-06-01

    Purpose: To develop the methodology to evaluate the clinical performance of a Phase II Proton CT scanner Methods: Range errors on the order of 3%-5% constitute a major uncertainty in current charged particle treatment planning based on Hounsfield Unit (HU)-relative stopping power (RSP) calibration curves. Within our proton CT collaboration, we previously developed and built a Phase I proton CT scanner that provided a sensitive area of 9 cm (axial) × 18 cm (in-plane). This scanner served to get initial experience with this new treatment planning tool and to incorporate lessons learned into the next generation design. A Phase II scanner was recently completed and is now undergoing initial performance testing. It will increase the proton acquisition rate and provide a larger detection area of 9 cm x 36 cm. We are now designing a comprehensive evaluation program to test the image quality, imaging dose, and range uncertainty associated with this scanner. The testing will be performed along the lines of AAPM TG 66. Results: In our discussion of the evaluation protocol we identified the following priorities. The image quality of proton CT images, in particular spatial resolution and low-density contrast discrimination, will be evaluated with the Catphan600 phantom. Initial testing showed that the Catphan uniformity phantom did not provide sufficient uniformity; it was thus replaced by a cylindrical water phantom. The imaging dose will be tested with a Catphan dose module, and compared to a typical cone beam CT dose for comparable image quality. Lastly, we developed a dedicated dosimetry range phantom based on the CIRS pediatric head phantom HN715. Conclusion: A formal evaluation of proton CT as a new tool for proton treatment planning is an important task. The availability of the new Phase II proton CT scanner will allow us to perform this task. This research is supported by the National Institute of Biomedical Imaging and Bioengineering of the NIH under award number R01

  9. Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

    Science.gov (United States)

    Ma, Chi; Chen, Baiyu; Koo, Chi Wan; Takahashi, Edwin A.; Fletcher, Joel G.; McCollough, Cynthia H.; Levin, David L.; Kuzo, Ronald S.; Viers, Lyndsay D.; Vincent Sheldon, Stephanie A.; Leng, Shuai; Yu, Lifeng

    2016-04-01

    Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58-0.78), 0.57 (95% CI: 0.46-0.68), and 0.62 (95% CI: 0.54-0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases.

  10. PET Motion Compensation for Radiation Therapy Using a CT-Based Mid-Position Motion Model: Methodology and Clinical Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kruis, Matthijs F.; Kamer, Jeroen B. van de; Houweling, Antonetta C.; Sonke, Jan-Jakob; Belderbos, José S.A.; Herk, Marcel van, E-mail: m.v.herk@nki.nl

    2013-10-01

    Purpose: Four-dimensional positron emission tomography (4D PET) imaging of the thorax produces sharper images with reduced motion artifacts. Current radiation therapy planning systems, however, do not facilitate 4D plan optimization. When images are acquired in a 2-minute time slot, the signal-to-noise ratio of each 4D frame is low, compromising image quality. The purpose of this study was to implement and evaluate the construction of mid-position 3D PET scans, with motion compensated using a 4D computed tomography (CT)-derived motion model. Methods and Materials: All voxels of 4D PET were registered to the time-averaged position by using a motion model derived from the 4D CT frames. After the registration the scans were summed, resulting in a motion-compensated 3D mid-position PET scan. The method was tested with a phantom dataset as well as data from 27 lung cancer patients. Results: PET motion compensation using a CT-based motion model improved image quality of both phantoms and patients in terms of increased maximum SUV (SUV{sub max}) values and decreased apparent volumes. In homogenous phantom data, a strong relationship was found between the amplitude-to-diameter ratio and the effects of the method. In heterogeneous patient data, the effect correlated better with the motion amplitude. In case of large amplitudes, motion compensation may increase SUV{sub max} up to 25% and reduce the diameter of the 50% SUV{sub max} volume by 10%. Conclusions: 4D CT-based motion-compensated mid-position PET scans provide improved quantitative data in terms of uptake values and volumes at the time-averaged position, thereby facilitating more accurate radiation therapy treatment planning of pulmonary lesions.

  11. High-resolution computed tomography of cholesteatoma of the middle ear. CT, otological, and surgical correlation

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Kiyoshi; Fukusumi, Akio; Okudera, Toshio; Kato, Toshihiko; Soda, Toyoji

    1988-08-01

    The high-resolution computed tomography (CT) appearances of 72 consecutive cases (92 ears) of chronic otomastoiditis were reviewed. The cholesteatomas were verified surgically and/or otologically in 35 of these 92 ears. Discussion was made with special emphasis on the differential diagnosis of cholesteatoma of the middle ear from the non-cholesteatoma otitis media. The CT findings suggestive of cholesteatoma were as follows: the definitive findings was of a soft-tissue opacity filling Purssak's space, with a medial displacement of the malleus and the incus; the possible findings were 1) a bony erosion of the wall of the middle ear cavity, 2) a partial or complete disappearance of the malleus and/or the incus, and 3) an opacification of Purssak's space and the superomedial aspect of the external auditory meatus.

  12. Age-related changes in the thymus gland: CT-pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Moore, A.V.; Korobkin, M.; Olanow, W.; Heaston, D.K.; Ram, P.C.; Dunnick, N.R.; Silverman, P.M.

    1983-08-01

    Recent reports suggest that computed tomography (CT) is useful for thymoma detection in patients with myasthenia gravis. However, that usefulness may be conditioned by the state of the normal thymus. To examine this concept, the CT findings in 64 consecutive patients with histologic confirmation of thymic status after thymectomy or thymic biopsy during mediastinal exploration were reviewed. The normal thymus has a bilobed, arrowhead-shaped cross section at all ages, with gradual focal or diffuse fatty infiltration of the parenchyma usually occurring between 20 and 40 years of age. A thymoma is usually a spherical or oval mass, often producing a focal, distinct bulge in the adjacent pleural reflection. The differentiation of thymoma from normal thymus should be possible in most patients if age-related changes in the normal gland are appreciated.

  13. Automatic landmark generation for deformable image registration evaluation for 4D CT images of lung

    Science.gov (United States)

    Vickress, J.; Battista, J.; Barnett, R.; Morgan, J.; Yartsev, S.

    2016-10-01

    Deformable image registration (DIR) has become a common tool in medical imaging across both diagnostic and treatment specialties, but the methods used offer varying levels of accuracy. Evaluation of DIR is commonly performed using manually selected landmarks, which is subjective, tedious and time consuming. We propose a semi-automated method that saves time and provides accuracy comparable to manual selection. Three landmarking methods including manual (with two independent observers), scale invariant feature transform (SIFT), and SIFT with manual editing (SIFT-M) were tested on 10 thoracic 4DCT image studies corresponding to the 0% and 50% phases of respiration. Results of each method were evaluated against a gold standard (GS) landmark set comparing both mean and proximal landmark displacements. The proximal method compares the local deformation magnitude between a test landmark pair and the closest GS pair. Statistical analysis was done using an intra class correlation (ICC) between test and GS displacement values. The creation time per landmark pair was 22, 34, 2.3, and 4.3 s for observers 1 and 2, SIFT, and SIFT-M methods respectively. Across 20 lungs from the 10 CT studies, the ICC values between the GS and observer 1 and 2, SIFT, and SIFT-M methods were 0.85, 0.85, 0.84, and 0.82 for mean lung deformation, and 0.97, 0.98, 0.91, and 0.96 for proximal landmark deformation, respectively. SIFT and SIFT-M methods have an accuracy that is comparable to manual methods when tested against a GS landmark set while saving 90% of the time. The number and distribution of landmarks significantly affected the analysis as manifested by the different results for mean deformation and proximal landmark deformation methods. Automatic landmark methods offer a promising alternative to manual landmarking, if the quantity, quality and distribution of landmarks can be optimized for the intended application.

  14. Evaluating dynamic contrast-enhanced and photoacoustic CT to assess intra-tumor heterogeneity in xenograft mouse models

    Science.gov (United States)

    Stantz, Keith M.; Liu, Bo; Cao, Minsong; Reinecke, Dan; Dzemidzic, Mario; Liang, Yun; Kruger, Robert

    2006-03-01

    Purpose: To evaluate photoacoustic CT spectroscopy (PCT-S) and dynamic contrast-enhanced CT (DCE-CT) ability to measure parameters - oxygen saturation and vascular physiology - associated with the intra-tumor oxygenation status. Material and Methods: Breast (VEGF165 enhance MCF-7) and ovarian (SKOV3x) cancer cells were implanted into the fat pads and flanks of immune deficient mice and allowed to grow to a diameter of 8-15 mm. CT was used to determine physiological parameters by acquiring a sequence of scans over a 10 minute period after an i.v. injection of a radio-opaque contrast agent (Isovue). These time-dependent contrast-enhanced curves were fit to a two-compartmental model determining tumor perfusion, fractional plasma volume, permeability-surface area produce, and fractional interstitial volume on a voxel-by-voxel basis. After which, the tumors were imaged using photoacoustic CT (Optosonics, Inc., Indianapolis, IN 46202). The near infrared spectra (700-910 nm) within the vasculature was fit to linear combination of measured oxy- and deoxy-hemoglobin blood samples to obtain oxygen saturation levels (SaO II). Results: The PCT-S scanner was first calibrated using different samples of oxygenated blood, from which a statistical error ranging from 2.5-6.5% was measured and a plot of the hemoglobin dissociation curve was consistent with empirical formula. In vivo determination of tumor vasculature SaO II levels were measurably tracked, and spatially correlated to the periphery of the tumor. Tumor depend variations in SaO II - 0.32 (ovarian) and 0.60 (breast) - and in vascular physiology - perfusion, 1.03 and 0.063 mL/min/mL, and fractional plasma volume, 0.20 and 0.07 - were observed. Conclusion: Combined, PCT-S and CED-CT has the potential to measure intra-tumor levels of tumor oxygen saturation and vascular physiology, key parameters associated with hypoxia.

  15. Helical CT for lumbosacral spinal

    Energy Technology Data Exchange (ETDEWEB)

    Tatsuno, Satoshi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine

    1996-10-01

    The aim of this study was to investigate the efficacy of helical CT for lumbosacral pathology. We performed helical CT with multiplanar reconstruction, including the formation of oblique transaxial and coronal images, in 62 patients with various lumboscral disorders, including 32 non-enhanced CT and 36 CT after myelography. We correlated the appearance of the stenotic spinal canal and neoplastic disease with the findings on MRI obtained at nearly the same time. We obtained helical CT images in all cases in about 30 seconds. The diagnostic ability of helical CT was roughly equal to that of MRI in patients with spondylosis deformans, spondylolisthesis and herniated nucleus pulposus. There was no significant difference in diagnostic value for degenerative lumbosacral disease with canal and foraminal stenosis between non-enhanced and post-myelography helical CT. However, non-enhanced helical CT could not clearly demonstrate neoplastic disease because of the poor contrast resolution. Helical CT was useful in evaluating degenerative disorder and its diagnostic value was nearly equal to that of MRI. We considered that helical CT may be suitable for the assessment of patients with severe lumbago owing to the markedly shortened examination time. However, if helical CT is used as a screening method for lumbosacral disease, one must be careful of its limitations, for example, poor detectability of neoplastic disease, vascular anomalies and so on. (author)

  16. Comparison of CE-FDG-PET/CT with CE-FDG-PET/MR in the evaluation of osseous metastases in breast cancer patients.

    Science.gov (United States)

    Catalano, O A; Nicolai, E; Rosen, B R; Luongo, A; Catalano, M; Iannace, C; Guimaraes, A; Vangel, M G; Mahmood, U; Soricelli, A; Salvatore, M

    2015-04-28

    Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40-75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 ((99)Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) imaging is an innovative technique still under investigation. We compared the capability of PET-MR to that of same-day PET-CT to assess osseous metastases in patients with breast cancer. One hundred and nine patients with breast cancer, who underwent same-day contrast enhanced (CE)-PET-CT and CE-PET-MR, were evaluated. CE-PET-CT and CE-PET-MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Binomial confidence intervals and a χ(2) test were used for categorical data, and paired t-test was used for the SUVmax data; a non-informative prior Bayesian approach was used to estimate and compare the specificities. Osseous metastases affected 25 out 109 patients. Metastases were demonstrated by CE-PET-CT in 22 out of 25 patients (88%±7%), and by CE-PET-MR in 25 out of 25 patients (100%). CE-PET-CT revealed 90 osseous metastases and CE-PET-MR revealed 141 osseous metastases (PCE-PET-CT and CE-PET-MR were 0.8519 and 0.9630, respectively. The estimated specificity for CE-FDG-PET-MR was 0.9884. The specificity of CE-PET-CT cannot be determined from patient-level data, because CE-PET-CT yielded a false-positive lesion in a patient who also had other, true metastases. CE-PET-MR detected a higher number of osseous metastases than did same-day CE-PET-CT, and was positive for 12% of the patients deemed osseous metastasis-negative on the basis of CE-PET-CT.

  17. PET/CT imaging in polymyalgia rheumatica: praepubic 18F-FDG uptake correlates with pectineus and adductor longus muscles enthesitis and with tenosynovitis

    Science.gov (United States)

    Sprlakova-Pukova, Andrea; Bortlicek, Zbynek; Fojtik, Zdenek; Kazda, Tomas; Joukal, Marek; Koukalova, Renata; Vasina, Jiri; Eremiasova, Jana; Nemec, Petr

    2017-01-01

    Abstract Background The role of 18F-fluorodeoxyglucose positron emission computed tomography (18F-FDG PET/CT) is increasing in the diagnosis of polymyalgia rheumatica (PMR), one of the most common inflammatory rheumatic diseases. In addition to other locations, increased 18F-FDG accumulation has been detected in the praepubic region in some patients. However, a deeper description and pathophysiological explanation of this increased praepubic accumulation has been lacking. The aim of the presented study is to confirm a decrease in praepubic 18F-FDG accumulation in response to therapy and to describe potential correlations to other 18F-FDG PET/CT scan characteristics during the course of disease. As a secondary objective, we describe the pathological aspects of the observed praepubic 18F-FDG uptake. Patients and methods A retrospective review of patients with newly suspected PMR undergoing baseline and follow up 18F-FDG PET/CT between February 2010 and March 2016 is given. Those with a visually detected presence of praepubic 18F-FDG accumulation were further analysed. The uptake was assessed visually and also semi-quantitatively in the defined region of interest by calculation of target-to-liver ratios. Other regions typical for PMR were systematically described as well (shoulders, hips, sternoclavicular joints, ischiogluteal bursae, spinous interspaces). Results Twenty-three out of 89 screened patients (26%) presented with initial praepubic 18F-FDG PET/CT positivity, 15 of whom also underwent follow up 18F-FDG PET/CT examination. Five out of 15 patients presented with increased 18F-FDG accumulation in large arteries as a sign of giant cell arteritis. During follow up examination, decrease in 18F-FDG accumulation caused by therapeutic intervention was observed in all evaluated locations in all analysed patients and no new positivity was indicated, including periarticular, extraarticular tissues or target large vessels. Praepubical accumulation of 18F-FDG was

  18. Evaluation of dose reduction and image quality in CT colonography: Comparison of low-dose CT with iterative reconstruction and routine-dose CT with filtered back projection

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Koichi [Kameda Medical Center, Department of Radiology, Kamogawa, Chiba (Japan); Jichi Medical University, Department of Radiology, Tochigi (Japan); National Cancer Center, Cancer Screening Technology Division, Research Center for Cancer Prevention and Screening, Tokyo (Japan); Fujiwara, Masanori; Mogi, Tomohiro; Iida, Nao [Kameda Medical Center Makuhari, Department of Radiology, Chiba (Japan); Kanazawa, Hidenori; Sugimoto, Hideharu [Jichi Medical University, Department of Radiology, Tochigi (Japan); Mitsushima, Toru [Kameda Medical Center Makuhari, Department of Gastroenterology, Chiba (Japan); Lefor, Alan T. [Jichi Medical University, Department of Surgery, Tochigi (Japan)

    2015-01-15

    To prospectively evaluate the radiation dose and image quality comparing low-dose CT colonography (CTC) reconstructed using different levels of iterative reconstruction techniques with routine-dose CTC reconstructed with filtered back projection. Following institutional ethics clearance and informed consent procedures, 210 patients underwent screening CTC using automatic tube current modulation for dual positions. Examinations were performed in the supine position with a routine-dose protocol and in the prone position, randomly applying four different low-dose protocols. Supine images were reconstructed with filtered back projection and prone images with iterative reconstruction. Two blinded observers assessed the image quality of endoluminal images. Image noise was quantitatively assessed by region-of-interest measurements. The mean effective dose in the supine series was 1.88 mSv using routine-dose CTC, compared to 0.92, 0.69, 0.57, and 0.46 mSv at four different low doses in the prone series (p < 0.01). Overall image quality and noise of low-dose CTC with iterative reconstruction were significantly improved compared to routine-dose CTC using filtered back projection. The lowest dose group had image quality comparable to routine-dose images. Low-dose CTC with iterative reconstruction reduces the radiation dose by 48.5 to 75.1 % without image quality degradation compared to routine-dose CTC with filtered back projection. (orig.)

  19. Triple Rule Out versus CT Angiogram Plus Stress Test for Evaluation of Chest Pain in the Emergency Department

    OpenAIRE

    Sawyer, Kelly N.; Payal Shah; Lihua Qu; Kurz, Michael C.; Clark, Carol L.; Swor, Robert A.

    2015-01-01

    Introduction: Undifferentiated chest pain in the emergency department (ED) is a diagnostic challenge. One approach includes a dedicated chest computed tomography (CT) for pulmonary embolism or dissection followed by a cardiac stress test (TRAD). An alternative strategy is a coronary CT angiogram with concurrent chest CT (Triple Rule Out, TRO). The objective of this study was to describe the ED patient course and short-term safety for these evaluation methods. Methods: This was ...

  20. Evaluating applicability of metal artifact reduction algorithm for head and neck radiation treatment planning CT

    Energy Technology Data Exchange (ETDEWEB)

    Son, Sang Jun; Park, Jang Pil; Kim, Min Jeong; Yoo, Suk Hyun [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2014-06-15

    The purpose of this study is evaluation for the applicability of O-MAR(Metal artifact Reduction for Orthopedic Implants)(ver. 3.6.0, Philips, Netherlands) in head and neck radiation treatment planning CT with metal artifact created by dental implant. All of the in this study's CT images were scanned by Brilliance Big Bore CT(Philips, Netherlands) at 120 kVp, 2 mm sliced and Metal artifact reduced by O-MAR. To compare the original and reconstructed CT images worked on RTPS(Eclipse ver 10.0.42, Varian, USA). In order to test the basic performance of the O-MAR, The phantom was made to create metal artifact by dental implant and other phantoms used for without artifact images. To measure a difference of HU in with artifact images and without artifact images, homogeneous phantom and inhomogeneous phantoms were used with cerrobend rods. Each of images were compared a difference of HU in ROIs. And also, 1 case of patient's original CT image applied O-MAR and density corrected CT were evaluated for dose distributions with SNC Patient(Sun Nuclear Co., USA). In cases of head and neck phantom, the difference of dose distribution is appeared 99.8% gamma passing rate(criteria 2 mm / 2%) between original and CT images applied O-MAR. And 98.5% appeared in patient case, among original CT, O-MAR and density corrected CT. The difference of total dose distribution is less than 2% that appeared both phantom and patient case study. Though the dose deviations are little, there are still matters to discuss that the dose deviations are concentrated so locally. In this study, The quality of all images applied O-MAR was improved. Unexpectedly, Increase of max. HU was founded in air cavity of the O-MAR images compare to cavity of the original images and wrong corrections were appeared, too. The result of study assuming restrained case of O-MAR adapted to near skin and low density area, it appeared image distortion and artifact correction simultaneously. In O-MAR CT, air cavity area

  1. Evaluations of multiplanar reconstruction in CT recognition of lumbar disk disease

    Energy Technology Data Exchange (ETDEWEB)

    Rosenthal, D.I.; Stauffer, A.E.; Davis, K.R.; Ganott, M.; Taveras, J.M.

    1984-07-01

    Axial computed tomographic (CT) images were compared with sagittal and coronal reformations and myelograms in 60 patients to evaluate the diagnostic usefulness of multiplanar reconstructions for the recognition of lumbar disk disease. The axial CT scans were most sensitive and specific. The sagittal scans were helpful in evaluating the neural foramina, the size of the disk bulge into the spinal canal, especially at L5-S1, and patients with spondylolisthesis. The coronal images were the least informative, although they contributed to the evaluation of lumbar nerve roots. The myelograms and the sagittal images were equally useful in the detection of herniated disk, but axial scans were superior to either. It was concluded that reformatted sagittal and coronal images are not required if all axial images are normal.

  2. Comparison of DCE-CT models for quantitative evaluation of Ktrans in larynx tumors

    Science.gov (United States)

    Oosterbroek, J.; Bennink, E.; Philippens, M. E. P.; Raaijmakers, C. P. J.; Viergever, M. A.; de Jong, H. W. A. M.

    2015-05-01

    Dynamic contrast enhanced CT (DCE-CT) can be used to estimate blood perfusion and vessel permeability in tumors. Tumor induced angiogenesis is generally associated with disorganized microvasculature with increased permeability or leakage. Estimated vascular leakage (Ktrans) values and their reliability greatly depend on the perfusion model used. To identify the preferred model for larynx tumor analysis, several perfusion models frequently used for estimating permeability were compared in this study. DCE-CT scans were acquired for 16 larynx cancer patients. Larynx tumors were delineated based on whole-mount histopathology after laryngectomy. DCE-CT data within these delineated volumes were analyzed using the Patlak and Logan plots, the Extended Tofts Model (ETM), the Adiabatic Approximation to the Tissue Homogeneity model (AATH) and a variant of AATH with fixed transit time (AATHFT). Akaike’s Information Criterion (AIC) was used to identify the best fitting model. Ktrans values from all models were compared with this best fitting model. Correlation strength was tested with two-tailed Spearman’s rank correlation and further examined using Bland-Altman plots. AATHFT was found to be the best fitting model. The overall median of individual patient medians Ktrans estimates were 14.3, 15.1, 16.1, 2.6 and 22.5 mL/100 g min  -  1 for AATH, AATHFT, ETM, Patlak and Logan, respectively. Ktrans estimates for all models except Patlak were strongly correlated (P  <  0.001). Bland-Altman plots show large biases but no significant deviating trend for any model other than Patlak. AATHFT was found to be the preferred model among those tested for estimation of Ktrans in larynx tumors.

  3. Comparison of DCE-CT models for quantitative evaluation of K(trans) in larynx tumors.

    Science.gov (United States)

    Oosterbroek, J; Bennink, E; Philippens, M E P; Raaijmakers, C P J; Viergever, M A; de Jong, H W A M

    2015-05-07

    Dynamic contrast enhanced CT (DCE-CT) can be used to estimate blood perfusion and vessel permeability in tumors. Tumor induced angiogenesis is generally associated with disorganized microvasculature with increased permeability or leakage. Estimated vascular leakage (K(trans)) values and their reliability greatly depend on the perfusion model used. To identify the preferred model for larynx tumor analysis, several perfusion models frequently used for estimating permeability were compared in this study. DCE-CT scans were acquired for 16 larynx cancer patients. Larynx tumors were delineated based on whole-mount histopathology after laryngectomy. DCE-CT data within these delineated volumes were analyzed using the Patlak and Logan plots, the Extended Tofts Model (ETM), the Adiabatic Approximation to the Tissue Homogeneity model (AATH) and a variant of AATH with fixed transit time (AATHFT). Akaike's Information Criterion (AIC) was used to identify the best fitting model. K(trans) values from all models were compared with this best fitting model. Correlation strength was tested with two-tailed Spearman's rank correlation and further examined using Bland-Altman plots. AATHFT was found to be the best fitting model. The overall median of individual patient medians K(trans) estimates were 14.3, 15.1, 16.1, 2.6 and 22.5 mL/100 g min(  -  1) for AATH, AATHFT, ETM, Patlak and Logan, respectively. K(trans) estimates for all models except Patlak were strongly correlated (P  <  0.001). Bland-Altman plots show large biases but no significant deviating trend for any model other than Patlak. AATHFT was found to be the preferred model among those tested for estimation of K(trans) in larynx tumors.

  4. Advanced dual-energy CT applications for the evaluation of the soft tissues of the neck.

    Science.gov (United States)

    Forghani, R; Mukherji, S K

    2017-05-02

    There are multiple emerging advanced computed tomography (CT) applications for the evaluation of the neck, many based on dual-energy CT (DECT). DECT is an advanced form of CT in which scan acquisition is performed at two different energies, enabling spectral tissue characterisation beyond what is possible with conventional single-energy CT and potentially providing a new horizon for quantitative analysis and tissue characterisation, particularly in oncological imaging. The purpose of this review is to familiarise the reader with DECT principles and review different clinical applications for the evaluation of the soft tissues of the neck. The article will begin with an overview of DECT scan acquisition, material characterisation, reconstructions, and basic considerations for implementation in the clinical setting. This will then be followed by a review of different clinical applications. The focus will be on oncological imaging, but artefact reduction and other miscellaneous applications will also be discussed. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Evaluation of CT in identifying colorectal carcinoma in the frail and disabled patient

    Energy Technology Data Exchange (ETDEWEB)

    Ng, C.S.; Dixon, A.K. [Department of Radiology, Addenbrooke' s NHS Trust and the University of Cambridge, Cambridge (United Kingdom); Doyle, T.C.; Courtney, H.M.; Bull, R.K.; Freeman, A.H. [Department of Radiology, Addenbrooke' s NHS Trust, Cambridge (United Kingdom); Pinto, E.M.; Prevost, A.T. [Department of Public Health and Primary Care, Institute of Public Health, Cambridge (United Kingdom); Campbell, G.A. [Department of Medicine for the Elderly, Addenbrooke' s NHS Trust, Cambridge (United Kingdom)

    2002-12-01

    Frail and physically or mentally disabled patients frequently have difficulty in tolerating formal colonic investigations. The aims of this study were to evaluate the accuracy of minimal-preparation CT in identifying colorectal carcinoma in this population and to determine the clinical indications and radiological signs with the highest yield for tumour. The CT technique involved helical acquisition (10-mm collimation, 1.5 pitch) following 2 days of preparation with oral contrast medium only. The outcome of 4 years of experience was retrospectively reviewed. The gold standards were pathological and cancer registration records, together with colonoscopy and barium enema when undertaken, with a minimum of 15 months follow-up. One thousand seventy-seven CT studies in 1031 patients (median age 80 years) were evaluated. CT correctly identified 83 of the 98 colorectal carcinomas in this group but missed 15 cases; sensitivity and specificity (with 95% confidence interval) 85% (78-92%) and 91% (90-93%), respectively. Multivariate analysis identified: (a) a palpable abdominal mass and anaemia to be the strongest clinical indications, particularly in combination (p<0.0025); and (b) lesion width and blurring of the serosal margin of lesions to be associated with tumours (p<0.0001). Computed tomography has a valuable role in the investigation of frail and otherwise disabled patients with symptoms suspicious for a colonic neoplasm. Although interpretation can be difficult, the technique is able to exclude malignancy with good accuracy. (orig.)

  6. 18 F-FDG PET-CT during chemo-radiotherapy in patients with non-small cell lung cancer: the early metabolic response correlates with the delivered radiation dose

    Directory of Open Access Journals (Sweden)

    Massaccesi Mariangela

    2012-07-01

    Full Text Available Abstract Background To evaluate the metabolic changes on 18 F-fluoro-2-deoxyglucose positron emission tomography integrated with computed tomography (18 F-FDG PET-CT performed before, during and after concurrent chemo-radiotherapy in patients with locally advanced non-small cell lung cancer (NSCLC; to correlate the metabolic response with the delivered radiation dose and with the clinical outcome. Methods Twenty-five NSCLC patients candidates for concurrent chemo-radiotherapy underwent 18 F-FDG PET-CT before treatment (pre-RT PET-CT, during the third week (during-RT PET-CT of chemo-radiotherapy, and 4 weeks from the end of chemo-radiotherapy (post-RT PET-CT. The parameters evaluated were: the maximum standardized uptake value (SUVmax of the primary tumor, the SUVmax of the lymph nodes, and the Metabolic Tumor Volume (MTV. Results SUVmax of the tumor and MTV significantly (p=0.0001, p=0.002, respectively decreased earlier during the third week of chemo-radiotherapy, with a further reduction 4 weeks from the end of treatment (p Conclusions In patients with locally advanced NSCLC, 18 F-FDG PET-CT performed during and after treatment allows early metabolic modifications to be detected, and for this SUVmax is the more sensitive parameter. Further studies are needed to investigate the correlation between the metabolic modifications during therapy and the clinical outcome in order to optimize the therapeutic strategy. Since the metabolic activity during chemo-radiotherapy correlates with the cumulative dose of fractionated radiotherapy delivered at the moment of the scan, special attention should be paid to methodological aspects, such as the radiation dose reached at the time of PET.

  7. Clinical role of early dynamic FDG-PET/CT for the evaluation of renal cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Reiko; Abe, Koichiro; Sakai, Shuji [Tokyo Women' s Medical University, Department of Diagnostic Imaging and Nuclear Medicine, Tokyo (Japan); Kondo, Tsunenori; Tanabe, Kazunari [Tokyo Women' s Medical University, Department of Urology, Tokyo (Japan)

    2016-06-15

    We studied the usefulness of early dynamic (ED) and whole-body (WB) FDG-PET/CT for the evaluation of renal cell carcinoma (RCC). One hundred patients with 107 tumours underwent kidney ED and WB FDG-PET/CT. We visually and semiquantitatively evaluated the FDG accumulation in RCCs in the ED and WB phases, and compared the accumulation values with regard to histological type (clear cell carcinoma [CCC] vs. non-clear cell carcinoma [N-CCC]), the TNM stage (high stage [3-4] vs. low stage [1-2]), the Fuhrman grade (high grade [3-4] vs. low grade [1-2]) and presence versus absence of venous (V) and lymphatic (Ly) invasion. In the ED phase, visual evaluation revealed no significant differences in FDG accumulation in terms of each item. However, the maximum standardized uptake value and tumour-to-normal tissue ratios were significantly higher in the CCCs compared to the N-CCCs (p < 0.001). In the WB phase, in contrast, significantly higher FDG accumulation (p < 0.001) was found in RCCs with a higher TNM stage, higher Furman grade, and the presence of V and Ly invasion in both the visual and the semiquantitative evaluations. ED and WB FDG-PET/CT is a useful tool for the evaluation of RCCs. (orig.)

  8. Helical CT findings and clinicopathologic featuresin malignant gastrointestinal stromal tumors: the correlation between radiologic appearance and malignant potential

    Institute of Scientific and Technical Information of China (English)

    Zhifeng Xu; Aizhen Pan; Fang Yong; Yingyu Chen; Bin Li; Qiang Gao; Renhua Wu

    2011-01-01

    Objective: In this pictorial essay, we described the clinical, pathologic, and computed tomographic (CT) findings of malignant gastrointestinal stromal tumors (MGISTs) and attempt to establish the correlation between radiologic appearance and malignant potential. Methods: This retrospective analysis included 20 patients receiving treatment for MGIST between 2008 and 2010. The diagnosis was established by pathology and immunohistochemistry. All these patients underwent pre-operative CT. Clinical presentation, pathology and CT images were analyzed. Helical CT images were reviewed for morpho-logic features such as tumor size, number and location, tumor margins, necrosis, degree of enhancement and metastasis. Results: Gastrointestinal bleeding, abdominal pain and discomfort, and without clinical symptom were common findings and were observed in 9 (45%), 6 (30%), and 5 (25%) of the 20 patients. 8 (40%) tumors were located in stomach, and 10 (50%), 1 (5%) and 1 (5%) were located in small intestine, mesentery and peritoneum, respectively. Male to female ratio was about 1:2. The size of MGIST ranged from 2.6 cm to 17.5 cm with a mean of 8.7 cm. All tumors density was inhomogeneous and heterogeneous enhancement. MGISTs with highly malignant located in small intestine were about 30% higher than stomach. The "satellite" tumours were found in 6 cases with high malignant risk. 7 cases were suffered from liver metastasis, and 4 cases went with seeding into the abdominal cavity, 1 cases went with lymph node metastasis. Histologically, 19 cases (95%) were of spindle cell type. Immunohistochemical stains demonstrated a strong positivity for both c-kit (CD117) and CD34s enhancement in 19 (95%). Conclusion: Clinical expression is varied in MGIST patients. Female might be predominance in MGIST. The GISTs located in small intestine would tend to be more aggressive. The satellite tumours, necrosis and cystic degeneration were strongly benefit for MGIST diagnosis. Furthermore, intestinal

  9. Helical CT evaluation of the chemical composition of urinary tract calculi with a discriminant analysis of CT-attenuation values and density

    Energy Technology Data Exchange (ETDEWEB)

    Bellin, Marie-France; Meric, Jean-Baptiste [AP-HP, Department of Radiology, Hopital Paul-Brousse, Villejuif Cedex (France); Renard-Penna, Raphaelle; Grenier, Philippe [AP-HP, Department of Radiology, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Conort, Pierre; Richard, Francois [AP-HP, Department of Urology, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Bissery, Anne; Mallet, Alain [AP-HP, Department of Biostatistics, Hopital Pitie-Salpetriere, Paris Cedex 13 (France); Daudon, Michel [AP-HP, Department of Biochemistry, Hopital Necker, Paris Cedex 15 (France)

    2004-11-01

    The aim of this study was to evaluate the efficacy of helical CT using a combination of CT-attenuation values and visual assessment of stone density as well as discriminant linear analysis to predict the chemical composition of urinary calculi. One hundred human urinary calculi were obtained from a stone-analysis laboratory and placed in 20 excised pig kidneys. They were scanned at 80, 120 and 140 kV with 3-mm collimation. Average, highest and lowest CT-attenuation values and CT variability were recorded. The internal calculus structure was assessed using a wide window setting, and visual assessment of stone density was recorded. A stepwise discriminant linear analysis was performed. The following three variables were discriminant: highest CT-attenuation value, visual density, and highest CT-attenuation value/area ratio, all at 80 kV. The probability of correctly classifying stone composition with these three variables was 0.64, ranging from 0.54 for mixed calculi to 0.69 for pure calculi. The probabilities of correctly classifying calculus composition were: 0.91 for calcium oxalate monohydrate and brushite, 0.89 for cystine, 0.85 for uric acid, 0.11 for calcium oxalate dihydrate, 0.10 for hydroxyapatite, and 0.07 for struvite calculi. When the first two ranks of highest probability for the accurate classification of each calculus type were taken into account, 81% of the calculi were correctly classified. Assessment at 80 kV of the highest CT-attenuation value, visual density and the highest CT-attenuation value/area ratio accurately predicts the chemical composition of 64-81% of urinary calculi. When the first two ranks of highest probability for the accurate classification of each calculus type were taken into account, all cystine, calcium oxalate monohydrate and brushite calculi were correctly classified. (orig.)

  10. Assessment of aortic stenosis after aortic valve replacement. Comparative evaluation of dual-source CT and echocardiography; Quantitative Evaluation der Aortenklappenoeffnungsflaeche mit der Dual-Source-CT und Korrelation mit der 2D-Echokardiografie. Initiale Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Saam, T.; Minaifar, N.; Becker, C.; Reiser, M.; Nikolaou, K. [Ludwig-Maximilians-Univ. Muenchen (Germany). Inst. fuer Klinische Radiologie; Oberhoffer, M.; Rist, C.; Vogt, F.; Reichart, B. [Ludwig-Maximilians-Univ. Muenchen (Germany). Herzchirurgische Klinik und Poliklinik

    2008-06-15

    Purpose: To prospectively evaluate whether planimetric measurements of aortic valve area (AVA) with dual-source computed tomography (DSCT) correlate with measurements obtained by echocardiography and to correlate the amount of calcification of the aortic valve with AVA in a group of patients after aortic valve replacement. Materials and Method: 23 patients underwent dual-source computed tomography (DSCT) of the heart (Somatom Definition, Siemens Medical Solutions, Forchheim, Germany), without heart rate control (heart rate 52-113 beats/minute). All patients had undergone aortic valve replacement (homografts, mean time after surgery: 7{+-}3 years). The AVA of the transplanted aortic valve graft was measured planimetrically by means of DSCT and compared with echocardiography as a standard of reference, to exclude post-surgical restenosis of the valve. Maximum AVA in systole planimetrically measured with CT was compared with calculated AVA values determined with the continuity equation, using transvalvular pressure gradients. The amount of calcification of the aortic valve was quantified and correlated (Spearman's R) with the AVA. To assess intra- and inter-reader reproducibility, the DCST data was re-analyzed by two readers 4 weeks after the initial review. Results: All DSCT datasets were of diagnostic image quality concerning valve depiction. The mean AVA as measured by DSCT was 2.7{+-}0.9 cm{sup 2} compared to 1.8{+-}0.5 cm{sup 2} by echocardiography (p<0.05). The planimetric evaluation of the CT data as compared to results of echocardiography showed a significant correlation of the results (Pearson's correlation coefficient R=0.78, p<0.001). Intra- and inter-reader reproducibility was good with intra-class correlation coefficients of 0.86 and 0.81, respectively (p<0.001). There was a significant negative correlation between the amount of aortic valve calcification and AVA as measured by echocardiography (R=-0.42; p<0.05) and as measured by DSCT (R=-0

  11. Clinical evaluation of a commercial orthopedic metal artifact reduction tool for CT simulations in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Li Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa [Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States); Department of Radiation Oncology, University of California Los Angeles, Los Angeles, California 90095 (United States); Department of Radiation Oncology, University of California San Diego, San Diego, California 92093 (United States); Philips Healthcare System, Cleveland, Ohio 44143 (United States); Department of Radiation Oncology, Washington University, St. Louis, Missouri 63110 (United States)

    2012-12-15

    Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose

  12. Interapophyseal joint synovial cyst of lumbar spine. CT scan and MR imaging correlation in two cases

    Energy Technology Data Exchange (ETDEWEB)

    Granat, O.; Jeanbourquin,D.; Perfettini, C.; Pernot, P.; Ducolombier, A.; Cosnard, G.

    1987-05-01

    Two patients presenting with L5 radiculagia were investigated by CT scan imaging. The origin of the pain was determined with certitude as arising from intraspinal development of an interapophyseal synovial cyst. Examination of the two cases by MR imaging provided conflicting results: in one patient images obtained by MR were not contributive and the synovial cyst would probably have been missed while in the other patient images were specific and very sensitive for diagnosis of interapophyseal synovial lesions. Treatment was surgical in both cases.

  13. The evaluation of 64-slice spiral CT perfusion to hepatic fibrosis of dog model and the correlation research with pathologic and VEGF change%犬肝纤维化64排螺旋CT全肝灌注成像及与病理对照、VEGF表达的相关研究

    Institute of Scientific and Technical Information of China (English)

    胡跃群; 章雅琴; 李丛蕊; 骆雷; 容鹏飞; 王维

    2011-01-01

    目的 利用64排螺旋CT全肝灌注模式成像测定中华田园犬肝纤维化模型的相关灌注参数并与病理对照来反映肝纤维化程度,分析其与VEGF表达水平的相关性.方法 采用腹腔注射50%四氯化碳油溶液辅以高脂饮食,建立犬肝纤维化模型,定期行64排螺旋CT全肝灌注成像及肝穿活检.根据病理分期分析各组CT灌注参数,并与VEGF表达水平作对照研究.结果 成功获得各期肝纤维化模型.对照组HAP(28.25 ±2.19) ml/(min·100 g),PVP( 53.53±10.71) ml/( min ·100 g),TLP(81.78±18.56) ml/(min·100 g);随肝纤维化程度加重,PVP、TLP持续性下降(P<0.05),HAP总体略呈上升趋势.PVP值、TLP值与肝纤维化程度呈负相关(P<0.01);VEGF表达水平随着肝纤维化程度的加重而明显增高(P<0.05).结论 腹腔注射四氯化碳油溶液辅以高脂饮食可以成功模拟人类从肝细胞变性、肝纤维化至肝硬化的全过程.64排螺旋CT全肝灌注成像克服了以往灌注成像的不足,且能反映肝纤维化各期的血流动力学变化趋势,VEGF可能在慢性肝病所致肝纤维化过程中起重要作用.%Objective To measure the perfusion parameters of liver fibrosis of dog model with 64-slice spiral CT,and compare with positive control to reflect the degree of liver fibrosis,and analyze the correlation with VEGF values.Methods Liver fibrosis was induced in dogs by intraperitoneal injection of CC14 and high fat diet.CT perfusion scan and liver biopsies were performed.The perfusion parameters were measured according to the liver fibrosis models,and the correlation with VEGF values was analyzed.Results The animals in experimental group were successfully induced different degree of liver fibrosis.In normal group,the hepatic artery perfusion,portal vein perfusion and total hepatic blood flow were (28.25 ±2.19)ml/(min · 100 g),(53.53 ± 10.71)ml/(min · 100 g) and (81.78 ± 18.56) ml/(min · 100 g).The PVP and TLP values of the

  14. Quantitative evaluation of benign meningioma and hemangiopericytoma with peritumoral brain edema by 64-slice CT perfusion imaging

    Institute of Scientific and Technical Information of China (English)

    REN Guang; CHEN Shuang; WANG Yin; ZHU Rui-jiang; GENG Dao-ying; FENG Xiao-yuan

    2010-01-01

    Background Hemangiopericytomas (HPCs) have a relentless tendency for local recurrence and metastases,differentiating between benign meningiomas and HPCs before surgery is important for both treatment planning and the prognosis appraisal.The purpose of this study was to evaluate the correlations between CT perfusion parameters and microvessel density (MVD) in extra-axial tumors and the possible role of CT perfusion imaging in preoperatively differentiating benign meningiomas and HPCs.Methods Seventeen patients with benign meningiomas and peritumoral edema, 12 patients with HPCs and peritumoral edema underwent 64-slice CT perfusion imaging pre-operation.Perfusion was calculated using the Patlak method.The quantitative parameters, include cerebral blood volume (CBV), permeability surface (PS) of parenchyma, peritumoral edema among benign meningiomas and HPCs were compared respectively.CBV and PS in parenchyma, peritumoral edema of benign meningiomas and HPCs were also compared to that of the contrallateral normal white matter respectively.The correlations between CBV, PS of tumoral parenchyma and MVD were examined.Results The value of CBV and PS in parenchyma of HPCs were significantly higher than that of benign meningiomas (P<0.05), while the values of CBV and PS in peritumoral edema of benign meningiomas and HPCs were not significantly different (P >0.05).MVD in parenchyma of HPCs were significantly higher than that of benign meningiomas (P<0.05).There were positive correlations between CBV and MVD (r=0.648, P<0.05), PS and MVD (r=0.541, P<0.05) respectively.Furthermore, the value of CBV and PS in parenchyma of benign meningiomas and HPCs were significantly higher than that of contrallateral normal white matter (P<0.05), the value of CBV in peritumoral edema of benign meningiomas and HPCs were significantly lower than that of contrallateral normal white matter (P<0.05), while the value of PS in peritumoral edema of benign meningiomas and HPCs were not

  15. Deep venous thrombosis with suspected pulmonary embolism: simultaneous evaluation using combined CT venography and pulmonary CT angiography; Trombose venosa profunda e suspeita de tromboembolismo pulmonar: avaliacao simultanea por meio de angiotomografia pulmonar e venotomografia combinadas

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Laura de Moraes [Universidade Federal, Rio de Janeiro (UFRJ), RJ (Brazil)]. E-mail: lauramgomes@terra.com.br; Marchiori, Edson [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Rodrigues, Rosana Souza [Hospital Copa D' Or, Rio de Janeiro, RJ (Brazil)

    2006-01-15

    Objective: To evaluate the occurrence and the correlation between pulmonary embolism (PE) and deep venous thrombosis (DVT) using a single CT angiography protocol. Materials and methods: This was a prospective study performed at Hospital Copa D'Or, Rio de Janeiro, Brazil from July 2003 to June 2004. We analyzed 116 CT angiography examinations of patients with clinical suspicion of PE. After an interval of approximately three minutes, venous phase images from the diaphragm to the knees were acquired without additional contrast injection in order to determine the presence of DVT. Results: From the 116 patients studied, 23 (19.8%) had PE, 24 (20.7%) had DVT, 15 (12.9%) had both PE and DVT and 9 (7.8%) had DVT alone. Among the 23 cases of PE, 15 (65.2%) had concomitant DVT whereas 8 (34.8%) had only PE. Among the 24 cases of DVT, 15 (62.5%) had associated PE and 9 (37.5%) had DVT alone. Conclusion: The results showed a strong relationship between PE and DVT, as well as the importance of investigating DVT in cases with suspected PE and the benefits of performing indirect CT venography after pulmonary CT angiography as a single examination alternative method for simultaneous investigation of PE and DVT. (author)

  16. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  17. CT-guided core needle biopsy of pleural lesions: Evaluating diagnostic yield and associated complications

    Energy Technology Data Exchange (ETDEWEB)

    Niu, Xiang Ke [Dept. of Radiology, Affiliated Hospital of Chengdu University, Chengdu (China); Bhetuwal, Anup; Yang, Han Feng [Dept. of Radiology, Sichuan Key Laboratory of Medical Imaging, Affiliated Hospital of North Sichuan Medical College, Nanchong (China)

    2015-02-15

    The purpose of this study was to retrospectively evaluate the diagnostic accuracy and complications of CT-guided core needle biopsy (CT-guided CNB) of pleural lesion and the possible effects of influencing factors. From September 2007 to June 2013, 88 consecutive patients (60 men and 28 women; mean [+/- standard deviation] age, 51.1 +/- 14.4 years; range, 19-78 years) underwent CT-guided CNB, which was performed by two experienced chest radiologists in our medical center. Out of 88 cases, 56 (63%) were diagnosed as malignant, 28 (31%) as benign and 4 (5%) as indeterminate for CNB of pleural lesions. The final diagnosis was confirmed by either histopathological diagnosis or clinical follow-up. The diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and complication rates were statistically evaluated. Influencing factors (patient age, sex, lesion size, pleural-puncture angle, patient position, pleural effusion, and number of pleural punctures) were assessed for their effect on accuracy of CT-guided CNB using univariate and subsequent multivariate analysis. Diagnostic accuracy, sensitivity, specificity, PPV, and NPV were 89.2%, 86.1%, 100%, 100%, and 67.8%, respectively. The influencing factors had no significant effect in altering diagnostic accuracy. As far as complications were concerned, occurrence of pneumothorax was observed in 14 (16%) out of 88 patients. Multivariate analysis revealed lesion size/pleural thickening as a significant risk factor (odds ratio [OR]: 8.744, p = 0.005) for occurrence of pneumothorax. Moreover, presence of pleural effusion was noted as a significant protective factor (OR: 0.171, p = 0.037) for pneumothorax. CT-guided CNB of pleural lesion is a safe procedure with high diagnostic yield and low risk of significant complications.

  18. Evaluation of CT findings for the differentiation of benign from malignant primary retroperitoneal tumors

    Institute of Scientific and Technical Information of China (English)

    Zhu Zheng; Zhao Xinming; Zhao Yanfeng; Yang Lei; Zhao Jing; Dai Jingrui; Zhou Chunwu

    2014-01-01

    Background Benign and malignant primary retroperitoneal tumors (RT) have different pathological manifestations,and overlapping imaging characteristics.This study aimed to evaluate the value of computed tomography (CT) for differentiating benign from malignant RT.Methods One hundred and ninety-four patients with clinical and radiographic data were evaluated retrospectively following surgical resection of primary RT.There were 38.1% (n=74) benign lesions and 61.9% (n=120) malignant lesions.Categorical variables were tested with a chi-square test or Fisher's exact test for the diagnostic indexes and sensitivity and specificity of CT characteristics.Results In univariate analysis,the differences in ill-defined margins,irregular surfaces,long diameter >6.75 cm,short diameter >6.25 cm,and solid or mixed texture had statistical significance; the sensitivity and specificity were 44.2% and 91.9%,70.0% and 62.2%,68.8% and 60.7%,59.7% and 74.2%,87.5% and 35.1%,respectively.In multivariate analysis,a combination of all the above indexes was the best model for differentiating malignant tumors,resulting in the most accurate diagnosis of malignancies with a sensitivity of 77.2% and a specificity of 81.1% (P<0.0001) when the score was 4.The differences in other findings including CT attenuation,number,and calcification had no statistical significance.The unique characteristics included the spotted enhancement (mottled high density)in schwannoma (P<0.0001),adipose tissue in liposarcoma (P<0.0001)and paravertebral location in neurogenic tumors (P<0.0001).Conclusions More accurate differential diagnosis of primary RT can be made through comprehensive analysis of the combined diagnostic indexes of CT.Some specific characteristics of CT can assist in preoperative planning.

  19. Evaluation of complex congenital cardiovascular anomalies using new, continuous rotation CT

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Tetsuhisa; Harada, Junta; Tada, Shimpei

    1987-12-01

    The slip ring and nutate/rotate configuration of the new fourth generation CT (TCT-900S, Toshiba Medical Co.) makes it possible to scan 30 slices continuously within 90 seconds. This scanner also provides real time hemodynamic and multiplanar reconstruction images. Studies were performed on 17 cases with complex congenital cardiovascular abnormalities. The findings correlated very well with those of angiocardiography and echocardiography. Assessment of the valve itself, though, was difficult, and combined use with echocardiography was considered to be indispensable. The real time multiplanar images were very effective in depicting coarctation of the aortic isthmus, ductus arteriosus, hypoplasia of the pulmonary artery, and ventricular septal defects for newborns and infants with small target regions. Real time cine displays could clearly show small atrial septal defects. This CT system was effective in studying complex congenital cardiovascular diseases.

  20. Visualization of Tooth for Non-Destructive Evaluation from CT Images

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hui; Chae, Ok Sam [Kyung Hee University, Seoul (Korea, Republic of)

    2009-06-15

    This paper reports an effort to develop 3D tooth visualization system from CT sequence images as a part of the non-destructive evaluation suitable for the simulation of endodontics, orthodontics and other dental treatments. We focus on the segmentation and visualization for the individual tooth. In dental CT images teeth are touching the adjacent teeth or surrounded by the alveolar bones with similar intensity. We propose an improved level set method with shape prior to separate a tooth from other teeth as well as the alveolar bones. Reconstructed 3D model of individual tooth based on the segmentation results indicates that our technique is a very conducive tool for tooth visualization, evaluation and diagnosis. Some comparative visualization results validate the non-destructive function of our method.

  1. CT and MR in non-neonatal hypoxic-ischemic encephalopathy: radiological findings with pathophysiological correlations

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Leonardo Guilhermino; Portela, Luiz Antonio Pezzi [Hospital Alemao Oswaldo Cruz and Hospital do Coracao, Diagnostic Imaging Division, Sao Paulo (Brazil); Rovira, Alex [University Hospital Vall d' Hebron, MR Unit, Department of Radiology, Barcelona (Spain); Costa Leite, Claudia da [Clinics Hospital of the University of Sao Paulo, School of Medicine, Department of Radiology, Sao Paulo (Brazil); Lucato, Leandro Tavares [Hospital Alemao Oswaldo Cruz and Hospital do Coracao, Diagnostic Imaging Division, Sao Paulo (Brazil); Clinics Hospital of the University of Sao Paulo, School of Medicine, Department of Radiology, Sao Paulo (Brazil)

    2010-11-15

    Non-neonatal hypoxic-ischemic encephalopathy is a clinical condition often related to cardiopulmonary arrest that demands critical management and treatment decisions. Management depends mainly on the degree of neurological impairment and prognostic considerations. Computed tomography (CT) is often used to exclude associated or mimicking pathology. If any, only nonspecific signs such as cerebral edema, sulci effacement, and decreased gray matter (GM)/white matter (WM) differentiation are evident. Pseudosubarachnoid hemorrhage, a GM/WM attenuation ratio <1.18, and inverted GM attenuation are associated with a poor prognosis. Magnetic resonance (MR) imaging is more sensitive than CT in assessing brain damage in hypoxic-ischemic encephalopathy. Some MR findings have similarities to those seen pathologically, based on spatial distribution and time scale, such as lesions distributed in watershed regions and selective injury to GM structures. In the acute phase, lesions are better depicted using diffusion-weighted imaging (DWI) because of the presence of cytotoxic edema, which, on T2-weighted images, only become apparent later in the early subacute phase. In the late subacute phase, postanoxic leukoencephalopathy and contrast enhancement could be observed. In the chronic phase, atrophic changes predominate over tissue signal changes. MR can be useful for estimating prognosis when other tests are inconclusive. Some findings, such as the extent of lesions on DWI and presence of a lactate peak and depleted N-acetyl aspartate peak on MR spectroscopy, seem to have prognostic value. (orig.)

  2. CoNNeCT Antenna Positioning System Dynamic Simulator Modal Model Correlation

    Science.gov (United States)

    Jones, Trevor M.; McNelis, Mark E.; Staab, Lucas D.; Akers, James C.; Suarez, Vicente J.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) developed an on-orbit, adaptable, Software Defined Radios (SDR)/Space Telecommunications Radio System (STRS)-based testbed facility to conduct a suite of experiments to advance technologies, reduce risk, and enable future mission capabilities on the International Space Station (ISS). The Communications, Navigation, and Networking reConfigurable Testbed (CoNNeCT) Project will provide NASA, industry, other Government agencies, and academic partners the opportunity to develop and field communications, navigation, and networking technologies in both the laboratory and space environment based on reconfigurable, software-defined radio platforms and the STRS Architecture. The CoNNeCT Payload Operations Nomenclature is SCAN Testbed, and this nomenclature will be used in all ISS integration, safety, verification, and operations documentation. The SCAN Testbed (payload) is a Flight Releasable Attachment Mechanism (FRAM) based payload that will launch aboard the Japanese H-II Transfer Vehicle (HTV) Multipurpose Exposed Pallet (EP-MP) to the International Space Station (ISS), and will be transferred to the Express Logistics Carrier 3 (ELC3) via Extravehicular Robotics (EVR). The SCAN Testbed will operate on-orbit for a minimum of two years.

  3. New method for evaluation of perigastric invasion of gastric cancer by right lateral position CT

    Energy Technology Data Exchange (ETDEWEB)

    Shirakawa, T. [Dept. of Radiology, Jikei Univ. School of Medicine, Tokyo (Japan); Fukuda, K. [Dept. of Radiology, Jikei Univ. School of Medicine, Tokyo (Japan); Tada, S. [Dept. of Radiology, Jikei Univ. School of Medicine, Tokyo (Japan)

    1996-06-01

    The purpose of this study was to evaluate usefulness of right lateral position CT in determining invasion of gastric cancer into adjacent organs. We assessed whether position shift, a change in the relative location of a gastric tumor and adjacent organs between the supine position and right lateral position CT, was a useful sign for absence of invasion into perigastric organs. In 37 patients with advanced gastric cancer with doubtful invasion into adjacent organs by conventional CT after 500 ml water oral intake, additive right lateral CT was performed. Of 24 cases of lesions in the gastric body, 16 had a position shift and no invasion into adjacent organs at surgery (T3), and 8 had no position shift and invasion (T4). The accuracy was 100%. Six gastric cardial and 7 pyloric tumors showed no position shift, and 3 cardial and 2 pyloric tumors were proved to be nonivasive (T3). The accuracy of cardial and pyloric tumor was 50 and 71%. We concluded that position shift may be useful in the diagnosis of invasion of adjacent organs by gastric cancer, limited to in cases with gastric body cancer. (orig.)

  4. Utility of head CT in the evaluation of vertigo/dizziness in the emergency department.

    Science.gov (United States)

    Lawhn-Heath, Courtney; Buckle, Christopher; Christoforidis, Gregory; Straus, Christopher

    2013-01-01

    Acute dizziness (including vertigo) is a common reason to visit the emergency room, and imaging with head CT is often performed initially to exclude a central cause. In this study, consecutive patients presenting with dizziness and undergoing head CT were retrospectively reviewed to determine diagnostic yield. Four hundred forty-eight consecutive head CTs in a representative sample of dizzy emergency room (ER) patients, including patients with other neurological symptoms, were reviewed to identify an acute or subacute cause for acute dizziness along with the frequency and modalities used in follow-up imaging. The diagnostic yield for head CT ordered in the ER for acute dizziness is low (2.2 %; 1.6 % for emergent findings), but MRI changes the diagnosis up to 16 % of the time, acutely in 8 % of cases. Consistent with the American College of Radiology appropriateness criteria and the literature, this study suggests a low diagnostic yield for CT in the evaluation of acute dizziness but an important role for MRI in appropriately selected cases.

  5. Use of FDG PET/CT for investigation of febrile neutropenia: evaluation in high-risk cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Guy, Stephen D.; Tramontana, Adrian R. [Western Health, Department of Infectious Diseases, Private Bag, Footscray, Victoria (Australia); University of Melbourne, Parkville, Victoria (Australia); Worth, Leon J.; Thursky, Karin A.; Slavin, Monica A. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Infectious Diseases, Melbourne, Victoria (Australia); Lau, Eddie; Hicks, Rodney J. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Centre for Cancer Imaging, Melbourne, Victoria (Australia); Seymour, John F. [University of Melbourne, Parkville, Victoria (Australia); Peter MacCallum Cancer Centre, Department of Haematology, Melbourne, Victoria (Australia)

    2012-08-15

    Febrile neutropenia (FNP) is a frequent complication of cancer care and evaluation often fails to identify a cause. [{sup 18} F]FDG PET/CT has the potential to identify inflammatory and infectious foci, but its potential role as an investigation for persistent FNP has not previously been explored. The aim of this study was to prospectively evaluate the clinical utility of FDG PET/CT in patients with cancer and severe neutropenia and five or more days of persistent fever despite antibiotic therapy. Adult patients with a diagnosis of an underlying malignancy and persistent FNP (temperature {>=}38 C and neutrophil count <500 cells/{mu}l for 5 days) underwent FDG PET/CT as an adjunct to conventional evaluation and management. The study group comprised 20 patients with FNP who fulfilled the eligibility criteria and underwent FDG PET/CT in addition to conventional evaluation. The median neutrophil count on the day of the FDG PET/CT scan was 30 cells/{mu}l (range 0-730 cells/{mu}l). Conventional evaluation identified 14 distinct sites of infection, 13 (93 %) of which were also identified by FDG PET/CT, including all deep tissue infections. FDG PET/CT identified 9 additional likely infection sites, 8 of which were subsequently confirmed as ''true positives'' by further investigations. FDG PET/CT was deemed to be of 'high' clinical impact in 15 of the 20 patients (75 %). This study supports the utility of FDG PET/CT scanning in severely neutropenic patients with five or more days of fever. Further evaluation of the contribution of FDG PET/CT in the management of FNP across a range of underlying malignancies is required. (orig.)

  6. CT evaluation of soft tissue and muscle infection and inflammation: A systematic compartmental approach

    Energy Technology Data Exchange (ETDEWEB)

    Beauchamp, N.J. Jr. [Dept. of Radiology, and Radiological Science, The Johns Hopkins Medical Institutions, Baltimore, MD (United States); Scott, W.W. Jr. [Dept. of Radiology, and Radiological Science, The Johns Hopkins Medical Institutions, Baltimore, MD (United States); Gottlieb, L.M. [Dept. of Surgery, The Johns Hopkins Medical Institutions, Baltimore, MD (United States); Fishman, E.K. [Dept. of Surgery, The Johns Hopkins Medical Institutions, Baltimore, MD (United States)

    1995-07-01

    This essay presents a systematic approach to the evaluation of soft tissue and muscle infection by defining the various pathologic processes and then illustrating them through a series of CT studies with corresponding schematic diagrams. The specific processes discussed are cellulitis, lymphangitis/lymphedema, necrotizing fascitis, myositis/myonecrosis, and abscess. Key points in the differential diagnosis of these entities are discussed and illustrated. The clinical management of the specific pathologic processes is also discussed. (orig./MG)

  7. Study on correlations between CT perfusion imagimg and changes of VEGF and MVD expressions of cervical cancer%宫颈癌 CT 灌注成像与 VEGF 、M VD 的相关性研究

    Institute of Scientific and Technical Information of China (English)

    周永; 余莹莹; 郭云泉; 文智; 张忠双

    2015-01-01

    Objective To analyze the correlation between CT perfusion parameters and changes of VEGF and MVD ex ‐pressions of cervical cancer and to evaluate its value in clinical use .Methods CT perfusion imaging was performed in 35 patients with cervical cancer diagnosed pathologically ,and 11 patients with cervical benign diseases were considered as con‐trol group .Time‐density curve was obtained by CT perfusion images .CT perfusion parameters were analyzed with patho‐logical and immunohistochemical observations .Results Time‐density curve in cervical cancer group showed rapid rise with gradual decline ,short time to peak and higher peak than control group .The values of BF ,BV ,PEI ,PMB ,M TT ,TTP for cervical cancer group and the values in control group showed statistical significance ( P < 0 .05) .MVD was positively correlated with CT perfusion parameters including BF ,BV ,PEI ,PMB ,but MVD was negatively correlated with M TT and TTP .MVD value in stage I and stage II showed difference statistically ( P < 0.05) ;There were statistical significant in VEGF expressions between benign and malignant groups ,different clinical stages and different pathological types ;there were statistical significant in MVD account between benign and malignant groups ,and different clinical stages ( P <0.05) .Three groups of different differentiation degree of cervical cancer between VEGF expression and MVD counts had difference ( P < 0 .05) ,but not statistically significant between groups .Conclusion Cervical cancer is one type of rich blood supply and high perfusion cancer ,CT perfusion imaging with VEGF and MVD expressions analysis provides a refer‐ential value for early diagnosis ,differentiation ,clinical treatment and prognosis .%目的:探讨宫颈癌CT灌注成像参数与血管内皮生长因子(VEGF)、微血管密度(MVD)的相关性及其临床应用价值。方法分析临床拟诊为宫颈癌的患者35例行宫颈 CT 灌注扫描,并与11例宫颈良

  8. Evaluation of adverse events and imaging quality in contrast-enhanced abdominal CT using generic CT contrast developed in South Korea: A multicenter prospective observational study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, You Sung [Dept. of Radiology, Ilsan Paik Hospital, College of Medicine, Inje University, Goyang (Korea, Republic of); Jung, Seung Eun; Park, Micheal Yong; Rha, Sung Eun [Dept. of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of); Lee, Soo Rim [Dept. of Radiology, Uijeongbu St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu (Korea, Republic of); Hwang, Seong Su [Dept. of Radiology, St. Vincent Hospital, College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of); Lim, Yeon Soo [Dept. of Radiology, Bucheon St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Bucheon (Korea, Republic of); Park, Jeong Mi [Dept. of Radiology, Yeouido St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, Seoul (Korea, Republic of)

    2017-02-15

    The purpose of this study is to evaluate the clinical safety and usefulness of the Prosure®300 in contrast-enhanced abdominal CT. This prospective study was approved by our center's Institutional Review Board. This study included 727 patients in four hospitals who underwent contrast-enhanced abdominal CT using Prosure®300 from December 2010 to June 2011. Adverse events were classified into minor and major adverse events. Logistic regression analysis was used to evaluate the relationship between adverse events and patient gender, age, underlying disease, and amount of injected contrast agent. Two radiologists independently evaluated imaging quality as poor, insufficient, sufficient, good, or very good. One hundred seventy-six out of 727 patients complained of adverse events, but most of them were minor adverse events. Five patients complained of dyspnea and one patient had hoarseness, but recovered without treatment. The rate of adverse events was significantly higher in men (p = 0.011), and a greater amount of injected contrast agent was related to a higher rate of adverse events (p = 0.000). Imaging quality was evaluated as 'good' or 'very good' in all cases. Prosure®300, a generic CT contrast agent developed in South Korea, can be used in contrast-enhanced abdominal CT.

  9. Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography

    Energy Technology Data Exchange (ETDEWEB)

    Coche, Emmanuel; Goncette, Louis; Maldague, Baudouin [Universite Catholique de Louvain, Department of Medical Imaging, Cliniques Universitaires St-Luc, Brussels (Belgium); Vlassenbroek, Alain [Philips Medical Systems, Cleveland, OH (United States); Roelants, Veronique [Universite Catholique de Louvain, Department of Nuclear Medicine, Cliniques Universitaires St-Luc, Brussels (Belgium); D' Hoore, William [Catholic University of Louvain, Public Health, Brussels (Belgium); Verschuren, Franck [Universite Catholique de Louvain, Department of Emergency Medicine, Cliniques Universitaires St-Luc, Brussels (Belgium)

    2005-07-01

    This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16 x 1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5{+-}2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions. (orig.)

  10. Evaluation of biventricular ejection fraction with ECG-gated 16-slice CT: preliminary findings in acute pulmonary embolism in comparison with radionuclide ventriculography.

    Science.gov (United States)

    Coche, Emmanuel; Vlassenbroek, Alain; Roelants, Véronique; D'Hoore, William; Verschuren, Franck; Goncette, Louis; Maldague, Baudouin

    2005-07-01

    This study aimed to assess the feasibility of cardiac global function evaluation during a whole-chest multi-slice CT (MSCT) acquisition in patients referred for suspicion of pulmonary embolism (PE), and to compare the results with planar equilibrium radionuclide ventriculography (ERNA). Ten consecutive haemodynamically stable patients (six female, four male; mean age 69.7 years; heart rate 65-99 bpm) with suspicion of PE underwent an MSCT and ERNA within a 6 h period. CT acquisition was performed after contrast medium injection by using 16x1.5 mm collimation and retrospective ECG gating. Left ventricular (LVEF) and right ventricular (RVEF) ejection fractions were calculated using dedicated three-dimensional software. Relationships between measurements obtained with MSCT and ERNA were assessed using linear regression analysis and reliability of MSCT was assessed with intra-class correlation coefficient. Bland-Altman analysis was performed to calculate limits of agreement between MSCT and ERNA. MSCT was performed successfully in ten patients with a mean acquisition time of 16.5+/-2.8 s. Functional cardiac evaluation was possible on CT for all patients except for one due to poor opacification of right ventricle. Linear regression analysis showed a good correlation between MSCT and ERNA for the LVEF (R=0.91) and the RVEF (R=0.89) measurements. Intra-class correlation was superior for LVEF (0.92) than for the RVEF (0.68). Bland-Altman plots demonstrated that MSCT substantially overestimated the ERNA RVEF. Morphological CT data demonstrated PE in four of ten of patients and alternative diagnoses in five of ten patients. Our study reveals that MSCT with retrospective ECG gating may provide in one modality a morphological and a functional cardiopulmonary evaluation. Comparison with ERNA demonstrated a good correlation for both ventricular ejection fractions.

  11. Canonical correlation analysis of course and teacher evaluation

    DEFF Research Database (Denmark)

    Sliusarenko, Tamara; Ersbøll, Bjarne Kjær

    2010-01-01

    At the Technical University of Denmark course evaluations are performed by the students on a questionnaire. On one form the students are asked specific questions regarding the course. On a second form they are asked specific questions about the teacher. This study investigates the extent to which...... information obtained from the course evaluation form overlaps with information obtained from the teacher evaluation form. Employing canonical correlation analysis it was found that course and teacher evaluations are correlated. However, the structure of the canonical correlation is subject to change...

  12. Intrasplenic masses of ``preserved`` functioning splenic tissue in sickle cell disease: correlation of imaging findings (CT, ultrasound, MRI, and nuclear scintigraphy)

    Energy Technology Data Exchange (ETDEWEB)

    Levin, T.L. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Berdon, W.E. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Haller, J.O. [Department of Radiology, SUNY Downstate Medical Center, Brooklyn, New York (United States); Ruzal-Shapiro, C. [Department of Radiology, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, 3959 Broadway, BHN 3-318, New York, NY 10032 (United States); Hurlet-Jenson, A. [Department of Pediatrics, Columbia-Presbyterian Medical Center, Babies and Children`s Hospital of New York, New York (United States)

    1996-09-01

    Purpose. We studied six patients with sickle cell disease (SSD), five homozygous for sickle cell anemia and one with sickle beta-thalassemia, in whom rounded intrasplenic masses proved to be preserved functioning splenic tissue. Materials and methods. Available images including computed tomography, ultrasonography, bone scans (Tc-99m MDP), liver spleen scans (Tc-99m sulfur colloid), and MRI were evaluated. Results. The masses were low density on CT (in an otherwise calcified spleen), hypoechoic relative to the echogenic spleen on US, and had the imaging characteristics of normal spleen on MRI. They failed to accumulate Tc-99m MDP but did demonstrate uptake of Tc-99m sulfur colloid. Conclusion. In a patient with SSD and intrasplenic masses, proper correlation of multiple imaging modalities will establish the diagnosis of functioning splenic tissue and avoid mistaken diagnosis of splenic abscess or infarction. (orig.). With 2 figs., 1 tab.

  13. Placing two parallel catheters by Seldinger`s approach through the femoral artery for CT angiography and CT during arterioportography. Evaluation of efficacy and safety

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Kazuhiro; Goto, Yasuyuki; Saito, Toshitaka [Musashino Red Cross Hospital, Tokyo (Japan); Wakabayashi, Yukari; Abe, Kimihiko

    1998-02-01

    The purpose of this study was to evaluate the efficacy and safety of placing two parallel catheters by Seldinger`s approach through the femoral artery for CT angiography (CTA) and CT during arterioportography (CTAP). We performed an analysis of 30 patients. Two introducers were successfully placed in all cases. Only one minor complication was observed, a localized inguinal hematoma. The CTA/CTAP procedures were successful in all patients except six who had anatomical variations of the hepatic arterial supply. Our methods proved to be useful and safe for patients with standard hepatic arterial supply. (author)

  14. Is Non-Contrast CT Adequate for the Evaluation of Hepatic Metastasis in Patients Who Cannot Receive Iodinated Contrast Media?

    Directory of Open Access Journals (Sweden)

    Han Bum Jee

    Full Text Available To evaluate the appropriateness of follow-up with only non-enhanced CT (NECT in patients with gastrointestinal cancer.This retrospective study included 323 patients with colorectal and gastric cancer who underwent two consecutive CT examinations (CT1 and CT2, including non-contrast and portal venous phase CT images, with an interval of 1 year. Patients were divided into 2 groups: Group A included patients with no hepatic metastasis on CT1 and with or without newly developed metastasis on CT2 to evaluate the diagnostic performance of NECT for detecting newly developed hepatic metastasis; Group B included patients with known hepatic metastasis both on CT1 and CT2 to evaluate the accuracy of NECT for the assessment of hepatic metastasis based on RECIST criteria (version 1.1. Contrast-enhanced CT (CECT images were considered as reference standards.Group A included 172 patients (M:F = 107:65; mean age, 62.6 years. Among them, 57 patients had 95 metastases (mean size, 2.2 ± 1.3 cm. Per patient and per lesion sensitivity for diagnosing newly developed hepatic metastasis was 56.1-66.7% and 52.6-56.8%, respectively. In terms of small metastases (<1.5 cm, per lesion sensitivity was significantly decreased to 28.1-34.4% (P < 0.05. Metastasis size measurements were significantly smaller on NECT (P < 0.001 compared with reference standards. In Group B, the accuracy of response evaluation based on RECIST criteria was 65.6-72.2%.NECT showed inadequate diagnostic performances in both detecting newly developed hepatic metastasis and evaluating the response of hepatic metastasis based on RECIST criteria.

  15. Quantitative assessment of first-pass perfusion using a low-dose method at multidetector CT in oesophageal squamous cell carcinoma: Correlation with VEGF expression

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.-W. [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China) and Sichuan Province Key Laboratory of Medical Imaging and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, 63 Wen Hua Lu, Nanchong, Sichuan 637000 (China); Yang, Z.-G., E-mail: yangzg1117@yahoo.com.cn [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); State Key Laboratory of Biotherapy, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Chen, H.-J. [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Li, Y.; Tang, S.-S.; Yao, J.; Dong, Z.-H. [Department of Radiology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China); He, D. [Department of Pathology, West China Hospital of Sichuan University, 37 Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2012-08-15

    Aim: To investigate the correlation between vascular endothelial cell growth factor (VEGF) expression and first-pass perfusion parameters at multidetector computed tomography (MDCT) using a low-dose technique, and to determine how to discriminate VEGF positivity from VEGF negativity by perfusion CT in oesophageal squamous cell carcinomas. Materials and methods: Thirty-two patients with oesophageal squamous cell carcinomas underwent first-pass perfusion with 64-section MDCT at 50 mAs. Perfusion parameters, including perfusion, peak enhanced density (PED), time to peak (TTP), and blood volume (BV), were measured. Postoperative specimens were assessed for VEGF expression. Correlation tests were performed to determine the associations between each CT perfusion parameter and VEGF expression. The cut-off values of perfusion parameters were obtained statistically to discriminate VEGF positivity from VEGF negativity. Results: Mean perfusion, PED, TTP, and BV were 38.47 {+-} 30.26 ml/min/ml, 24.68 {+-} 9.65 HU, 28.35 {+-} 9.03 s, and 11.82 {+-} 6.06 ml/100 g, respectively. PED or BV were significantly higher in the VEGF-positive group than in the VEGF-negative group (all p < 0.05), but no significant difference in perfusion or TTP was found between the VEGF-positive and VEGF-negative groups (all p > 0.05). In VEGF positivity, PED and BV were correlated with VEGF expression (r = 0.576 and 0.765, respectively; all p < 0.05), whereas perfusion and TTP were not (r = 0.361 and 0.239, respectively; all p > 0.05). A threshold of BV (10.23 ml/100 g) achieved a sensitivity of 94.4%, and a specificity of 92.9% for discriminating VEGF positivity from VEGF negativity. Conclusion: BV could reflect tumour VEGF expression, and could be an indicator for evaluating angiogenesis in oesophageal tumours.

  16. [gamma]-ray CT examination of density gradients in slip ceramics: correlation with stress distribution

    Energy Technology Data Exchange (ETDEWEB)

    Sawicka, B.D. (AECL Research, Chalk River Labs., Ontario (Canada)); Murphy, J.G.; Taheri, F.; Kanary, L.E. (Advanced Materials Engineering Centre, Halifax, Nova Scotia (Canada))

    1992-06-01

    Residual stresses caused by processing techniques reduce the safe allowable design life of components. This is especially critical for brittle materials, like ceramics, which do not exhibit plastic deformation. During development of the manufacturing process for an experimental high-precision ceramic component, a characteristic cracking pattern occurred in a series of prototypes, which suggested development of stresses during densification, either during drying or sintering. To examine parameters which may influence the development of these residual stresses, a series of simple geometry specimens were prepared and characterized for density gradients using computed tomography (CT). Using the measured values of density gradients, a model of the sintering process was made and the resultant stress distribution in the parts calculated. Results indicate that the use of nonlinear finite element analysis in conjunction with hypoelastic materials modeling qualitatively represents the sintering stresses.

  17. γ-ray CT examination of density gradients in slip cast ceramics: correlation with stress distribution

    Science.gov (United States)

    Sawicka, B. D.; Murphy, J. G.; Taheri, F.; Kanary, L. E.

    1992-06-01

    Residual stresses caused by processing techniques reduce the safe allowable design life of components. This is especially critical for brittle materials, like ceramics, which do not exhibit plastic deformation. During development of the manufacturing process for an experimental high-precision ceramic component, a characteristic cracking pattern occurred in a series of prototypes, which suggested development of stresses during densification, either during drying or sintering. To examine parameters which may influence the development of these residual stresses, a series of simple geometry specimens were prepared and characterized for density gradients using computed tomography (CT). Using the measured values of density gradients, a model of the sintering process was made and the resultant stress distribution in the parts calculated. Results indicate that the use of nonlinear finite element analysis in conjunction with hypoelastic materials modelling qualitatively represents the sintering stresses.

  18. Novel Influenza A (H1N1) Virus Infection in Children: Chest Radiographic and CT Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Min Jeong; Lee, Young Seok; Lee, Jee Young; Lee, Kun Song [Dankook University College of Medicine, Dankook University Hospital, Cheonan (Korea, Republic of)

    2010-12-15

    The purpose of this study was to evaluate the chest radiographic and CT findings of novel influenza A (H1N1) virus infection in children, the population that is more vulnerable to respiratory infection than adults. The study population comprised 410 children who were diagnosed with an H1N1 infection from August 24, 2009 to November 11, 2009 and underwent chest radiography at Dankook University Hospital in Korea. Six of these patients also underwent chest CT. The initial chest radiographs were classified as normal or abnormal. The abnormal chest radiographs and high resolution CT scans were assessed for the pattern and distribution of parenchymal lesions, and the presence of complications such as atelectasis, pleural effusion, and pneumomediastinum. The initial chest radiograph was normal in 384 of 410 (94%) patients and abnormal in 26 of 410 (6%) patients. Parenchymal abnormalities seen on the initial chest radiographs included prominent peribronchial marking (25 of 26, 96%), consolidation (22 of 26, 85%), and ground-glass opacities without consolidation (2 of 26, 8%). The involvement was usually bilateral (19 of 26, 73%) with the lower lung zone predominance (22 of 26, 85%). Atelectasis was observed in 12 (46%) and pleural effusion in 11 (42%) patients. CT (n = 6) scans showed peribronchovascular interstitial thickening (n = 6), ground-glass opacities (n = 5), centrilobular nodules (n = 4), consolidation (n = 3), mediastinal lymph node enlargement (n = 5), pleural effusion (n = 3), and pneumomediastinum (n = 3). Abnormal chest radiographs were uncommon in children with a swine-origin influenza A (H1N1) virus (S-OIV) infection. In children, H1N1 virus infection can be included in the differential diagnosis, when chest radiographs and CT scans show prominent peribronchial markings and ill-defined patchy consolidation with mediastinal lymph node enlargement, pleural effusion and pneumomediastinum

  19. CT of the chest in the evaluation of idiopathic pulmonary arterial hypertension in children

    Energy Technology Data Exchange (ETDEWEB)

    Chaudry, Gulraiz [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Children' s Hospital Boston, Department of Radiology, Boston, MA (United States); MacDonald, Cathy; Gundogan, Munire; Manson, David [University of Toronto, Department of Diagnostic Imaging, The Hospital for Sick Children, Toronto (Canada); Adatia, Ian [UCSF Children' s Hospital, Department of Pediatric Cardiology, San Francisco, CA (United States)

    2007-04-15

    Idiopathic pulmonary arterial hypertension (IPAH) is a rare disease in children. By definition it is a diagnosis of exclusion, and CT of the chest is primarily performed to exclude other causes. Previous studies have defined CT features suggestive of the diagnosis of IPAH, but these have all been limited to the adult population. Contrast-enhanced chest CT and high-resolution CT findings in IPAH were evaluated in an attempt to define features consistently seen in children with this condition. The chest CT scans performed at initial presentation were reviewed in 17 children with echocardiographic or angiographic evidence of IPAH. There were nine boys and eight girls, ranging in age from 1 month to 17 years. The extrapulmonary findings included cardiomegaly with right-sided cardiac enlargement, which was seen in 13 children. The central pulmonary arteries were enlarged in 15 children, with peripheral enlargement in two. In six children this resulted in bronchial compression. In addition, mediastinal and hilar lymphadenopathy was noted in three children. Prominent intrapulmonary features included a peripheral vasculopathy, with enlarged tortuous vessels, seen in eight children. Ill-defined ground-glass centrilobular opacities were also noted in eight children, representing the most common parenchymal abnormality. Other findings included septal lines in five, diffuse ground-glass opacification in four and focal hyperlucent zones in three. Mosaic attenuation was seen in one child. A variety of imaging findings are identified in IPAH. Features particularly consistent with the diagnosis include peripheral vasculopathy and centrilobular opacities in the setting of cardiomegaly and central pulmonary arterial enlargement. (orig.)

  20. Size variation and collapse of emphysema holes at inspiration and expiration CT scan: evaluation with modified length scale method and image co-registration.

    Science.gov (United States)

    Oh, Sang Young; Lee, Minho; Seo, Joon Beom; Kim, Namkug; Lee, Sang Min; Lee, Jae Seung; Oh, Yeon Mok

    2017-01-01

    A novel approach of size-based emphysema clustering has been developed, and the size variation and collapse of holes in emphysema clusters are evaluated at inspiratory and expiratory computed tomography (CT). Thirty patients were visually evaluated for the size-based emphysema clustering technique and a total of 72 patients were evaluated for analyzing collapse of the emphysema hole in this study. A new approach for the size differentiation of emphysema holes was developed using the length scale, Gaussian low-pass filtering, and iteration approach. Then, the volumetric CT results of the emphysema patients were analyzed using the new method, and deformable registration was carried out between inspiratory and expiratory CT. Blind visual evaluations of EI by two readers had significant correlations with the classification using the size-based emphysema clustering method (r-values of reader 1: 0.186, 0.890, 0.915, and 0.941; reader 2: 0.540, 0.667, 0.919, and 0.942). The results of collapse of emphysema holes using deformable registration were compared with the pulmonary function test (PFT) parameters using the Pearson's correlation test. The mean extents of low-attenuation area (LAA), E1 (size variation and collapse of emphysema holes may be useful for understanding the dynamic collapse of emphysema and its functional relation.

  1. Role of 3D-CT for orthodontic and ENT evaluation in Goldenhar syndrome.

    Science.gov (United States)

    Saccomanno, S; Greco, F; D'Alatri, L; De Corso, E; Pandolfini, M; Sergi, B; Pirronti, T; Deli, R

    2014-08-01

    Goldenhar syndrome is a congenital condition that includes anomalies of the derivatives of the first and second brachial arches, vertebral defects and ocular abnormalities. It is also known as oculo-auriculo-vertebrale syndrome (OAVS), hemifacial microsomia, or first or second brachial arch syndrome. It was first described by Van Duyse in 1882 and better studied by M. Goldenhar in 1952. Its treatment requires a multidisciplinary approach. Herein, we describe the value of 3D-CT evaluation in a patient with Goldenhar syndrome, with particular regard to planning diagnostic and therapeutic approach. A 7-year-old boy with Goldenhar syndrome with definite post-natal genetic diagnosis was referred to our Department of Radiology for neuroimaging of the temporal bone. By 3D-CT evaluation of this young patient we observed the asymmetry of the condyles with the right one dysmorphic, short and wide; the auricle of the right ear was replaced by a dysmorphic rough; the right middle ear had a hypoplastic tympanic cavity and the internal auditory canal of right ear was atresic. In our experience, 3D-CT is a powerful diagnostic instrument and offers many advantages: volumetric reproduction of cranium and soft tissues, no overlap of anatomic parts that limits the visibility of various structures, high precision and assurance of images, and a constant and easily reproducible reference system. In our case, 3D-CT offered a very complete evaluation of all malformations of mandibular and temporal bone that characterize this syndrome and representing an important step for ENT and orthodontic therapeutic approaches.

  2. Peripheral bronchogenic carcinoma:Enhancement pattern evaluation on PACS and CT workstations

    Institute of Scientific and Technical Information of China (English)

    Chunlei Lv; Shenjiang Li; Changcheng Li; Debin Liu; Wenjie Liang; Feng Zhu; Yan Zhu; Xuefeng Cui

    2014-01-01

    Objective: The aim of the study was to determine the ef iciency and ef ectiveness of picture archiving and com-munication system (PACS) workstation in detecting enhancement pattern of peripheral bronchogenic carcinoma. Methods:The 62 patients with peripheral bronchogenic carcinoma underwent two-phase contrast material-enhanced multislices com-puted tomography (MSCT) of the chest in a single-breath-hold technique. Two spiral CT scans were obtained at 25 s and 90 s respectively after nonionic contrast material was administrated via the antecubital vein at a rate of 4 mL/s by using an autoinjector. Precontrast and postcontrast attenuation on every scan were measured on PACS and CT workstations respec-tively and peak height was calculated. Enhancement pattern was evaluated on the image obtained at 90 s after injection of contrast medium on PACS and CT workstations respectively. Results: No statistical y significant dif erence in precontrast attenuation, postcontrast attenuation at 25 s and 90 s was found between these measured on a PACS workstation [(40.21 ± 7.03) HU; (55.53 ± 11.09) HU; (75.95 ± 13.45) HU] and those [(39.01 ± 8.95) HU; (56.01 ± 10.91) HU; (76.03 ± 11.95) HU] on a CT workstation (t = 1.140, P = 0.256 > 0.05; t = 1.580, P = 0.149 > 0.05; t = 1.505, P = 0.150﹥0.05). The peak height that calculated on a PACS workstation was 35.74 HU (20 HU). There was not statistical y significant dif erence in peak height between that calculated on a PACS workstation and that on a CT workstation [(37.02 ± 12.05) HU; t = 2.001, P = 0.099 >0.05]. The tumors showed same enhancement pattern on PACS workstation and CT workstation. Of the 62 cases, 38 showed homogeneous enhancement, 17 showed heterogeneous enhancement, five showed peripheral enhancement, two showed central enhancement, at 90 s. The enhancement pattern revealed on PACS workstation was consistent with feature of periph-eral bronchogenic carcinoma. Conclusion: The ef iciency and ef ectiveness of PACS

  3. Acute appendicitis: prospective evaluation of a diagnostic algorithm integrating ultrasound and low-dose CT to reduce the need of standard CT

    Energy Technology Data Exchange (ETDEWEB)

    Poletti, Pierre-Alexandre; Platon, Alexandra [University Hospital of Geneva, Department of Radiology, Geneva (Switzerland); University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Perrot, Thomas de; Becker, Christoph D. [University Hospital of Geneva, Department of Radiology, Geneva (Switzerland); Sarasin, Francois; Rutschmann, Olivier [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); Andereggen, Elisabeth [University Hospital of Geneva, Emergency Center, Geneva (Switzerland); University Hospital of Geneva, Department of Surgery, Geneva (Switzerland); Dupuis-Lozeron, Elise; Perneger, Thomas [University Hospital of Geneva, Division of Clinical Epidemiology, Geneva (Switzerland); Gervaz, Pascal [University Hospital of Geneva, Department of Surgery, Geneva (Switzerland)

    2011-12-15

    To evaluate an algorithm integrating ultrasound and low-dose unenhanced CT with oral contrast medium (LDCT) in the assessment of acute appendicitis, to reduce the need of conventional CT. Ultrasound was performed upon admission in 183 consecutive adult patients (111 women, 72 men, mean age 32) with suspicion of acute appendicitis and a BMI between 18.5 and 30 (step 1). No further examination was recommended when ultrasound was positive for appendicitis, negative with low clinical suspicion, or demonstrated an alternative diagnosis. All other patients underwent LDCT (30 mAs) (step 2). Standard intravenously enhanced CT (180 mAs) was performed after indeterminate LDCT (step 3). No further imaging was recommended after ultrasound in 84 (46%) patients; LDCT was obtained in 99 (54%). LDCT was positive or negative for appendicitis in 81 (82%) of these 99 patients, indeterminate in 18 (18%) who underwent standard CT. Eighty-six (47%) of the 183 patients had a surgically proven appendicitis. The sensitivity and specificity of the algorithm were 98.8% and 96.9%. The proposed algorithm achieved high sensitivity and specificity for detection of acute appendicitis, while reducing the need for standard CT and thus limiting exposition to radiation and to intravenous contrast media. (orig.)

  4. Acute appendicitis: prospective evaluation of a diagnostic algorithm integrating ultrasound and low-dose CT to reduce the need of standard CT.

    Science.gov (United States)

    Poletti, Pierre-Alexandre; Platon, Alexandra; De Perrot, Thomas; Sarasin, Francois; Andereggen, Elisabeth; Rutschmann, Olivier; Dupuis-Lozeron, Elise; Perneger, Thomas; Gervaz, Pascal; Becker, Christoph D

    2011-12-01

    To evaluate an algorithm integrating ultrasound and low-dose unenhanced CT with oral contrast medium (LDCT) in the assessment of acute appendicitis, to reduce the need of conventional CT. Ultrasound was performed upon admission in 183 consecutive adult patients (111 women, 72 men, mean age 32) with suspicion of acute appendicitis and a BMI between 18.5 and 30 (step 1). No further examination was recommended when ultrasound was positive for appendicitis, negative with low clinical suspicion, or demonstrated an alternative diagnosis. All other patients underwent LDCT (30 mAs) (step 2). Standard intravenously enhanced CT (180 mAs) was performed after indeterminate LDCT (step 3). No further imaging was recommended after ultrasound in 84 (46%) patients; LDCT was obtained in 99 (54%). LDCT was positive or negative for appendicitis in 81 (82%) of these 99 patients, indeterminate in 18 (18%) who underwent standard CT. Eighty-six (47%) of the 183 patients had a surgically proven appendicitis. The sensitivity and specificity of the algorithm were 98.8% and 96.9%. The proposed algorithm achieved high sensitivity and specificity for detection of acute appendicitis, while reducing the need for standard CT and thus limiting exposition to radiation and to intravenous contrast media.

  5. Correlation of minimum apparent diffusion coefficient with maximum standardized uptake on fluorodeoxyglucose PET-CT in patients with rectal adenocarcinoma.

    Science.gov (United States)

    Er, Hale Çolakoğlu; Erden, Ayşe; Küçük, N Özlem; Geçim, Ethem

    2014-01-01

    The aim of this study was to retrospectively assess the correlation between minimum apparent diffusion coefficient (ADCmin) values obtained from diffusion-weighted magnetic resonance imaging (MRI) and maximum standardized uptake values (SUVmax) obtained from positron emission tomography-computed tomography (PET-CT) in rectal cancer. Forty-one patients with pathologically confirmed rectal adenocarcinoma were included in this study. For preoperative staging, PET-CT and pelvic MRI with diffusion-weighted imaging were performed within one week (mean time interval, 3±1 day). For ADC measurements, the region of interest (ROI) was manually drawn along the border of each hyperintense tumor on b=1000 s/mm2 images. After repeating this procedure on each consecutive tumor-containing slice to cover the entire tumoral area, ROIs were copied to ADC maps. ADCmin was determined as the lowest ADC value among all ROIs in each tumor. For SUVmax measurements, whole-body images were assessed visually on transaxial, sagittal, and coronal images. ROIs were determined from the lesions observed on each slice, and SUVmax values were calculated automatically. The mean values of ADCmin and SUVmax were compared using Spearman's test. The mean ADCmin was 0.62±0.19×10-3 mm2/s (range, 0.368-1.227×10-3 mm2/s), the mean SUVmax was 20.07±9.3 (range, 4.3-49.5). A significant negative correlation was found between ADCmin and SUVmax (r=-0.347; P = 0.026). There was a significant negative correlation between the ADCmin and SUVmax values in rectal adenocarcinomas.

  6. Comparative evaluation of cone-beam CT equipment with micro-CT in the visualization of root canal system

    Directory of Open Access Journals (Sweden)

    Bence Tamas Szabo

    2012-01-01

    Full Text Available The aim of this study was to compare three different cone-beam CT (CBCT instruments used in dental clinical practice with micro-CT as gold standard. Three female monkeys’ (Macaca fascicularis skulls were selected and scanned by the tested CBCT-s. The most apical visible root canal level on the CBCT images was used as reference level (RL. After the image acquisition by CBCT-s dental jaw sections were scanned by micro-CT at a resolution of 17 μm. Out of the left second and third molars 25 root canals were selected and analysed by three observers at RL and following cross sectional parameters were determined: area of the lumen, major and minor diameters, aspect ratio and mean thickness. Results suggest that only high resolution CBCT instruments allow dentists detecting the full length of the root canal.

  7. Atypical CT findings in bacterial meningoencephalitis

    Energy Technology Data Exchange (ETDEWEB)

    Fink, I.J.; Dillon, W.P.; Brant-Zawadzki, M.; Danziger, A.; Rechthand, E.

    1984-01-01

    Computed tomography has become a valuable imaging modality in the evaluation and management of most intracerebral infections. We report two cases of intracranial infections with atypical CT findings, and attempt to correlate these findings with the pathophysiology.

  8. CT-discography in the evaluation of the post-operative lumbar spine. Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Crenier, N.; Greselle, J.F.; Richard, O.; Houang, B.; Pinol-Daubisse, H.; Caille, J.M.; Vital, J.M.; Senegas, J.

    1988-06-01

    Thirty-three patients with recurrent sciatica after lumbar-disk surgery were studied for recurrent herniated nucleus pulposus (HNP) by CT alone and CT-discography (CTD). Twenty-six patients underwent surgical reexploration allowing correlation with CTD. CTD made a correct diagnosis of recurrent HNP in twenty-one patients showing an extravasation of the contrast medium from the disk space into the medullary canal. In two cases CTD was positive for recurrent HNP but surgery showed only fibrosis. The amount of contrast leak was very small in these two cases along the posterior common longitudinal ligament, and the junction with the disk was very narrow. Because of their clinical presentation three patients with negative studies were operated upon. One showed only fibrosis and the two others showed an associated disk fragment. Among the twenty-one true-positive cases, seven showed a combination of recurrent HNP and scarring. Contamination of CSF by the contrast medium through the dura was observed in two patients. Although a prospective comparative study between CTD and IV-contrast-enhanced CT is necessary, CTD appears to be a useful diagnostic procedure for recurrent HNP after surgery of the lumbar spine.

  9. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, Nilesh N., E-mail: nmistry@som.umaryland.edu [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Diwanji, Tejan; Shi, Xiutao [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Pokharel, Sabin [Morgan State University, Baltimore, Maryland (United States); Feigenberg, Steven [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States); Scharf, Steven M. [Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland (United States); D' Souza, Warren D. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland (United States)

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic

  10. Low-Radiation-Dose Modified Small Bowel CT for Evaluation of Recurrent Crohn's Disease

    Directory of Open Access Journals (Sweden)

    A. Z. Kielar

    2012-01-01

    Full Text Available Crohn's disease affects any part of the GI tract, commonly the terminal ileum. To decrease radiation exposure we developed a low-radiation-dose unenhanced CT (modified small Bowel CT, MBCT to evaluate the small bowel using hyperdense oral contrast. Technique. MBCT was investigated in patients with pathologically proven Crohn's disease presenting with new symptoms from recurrent inflammation or stricture. After ethics board approval, 98 consecutive patients were retrospectively evaluated. Kappa values from two independent reviewers were calculated for presence of obstruction, active inflammation versus chronic stricture, and ancillary findings. Forty-two patients underwent surgery or colonoscopy within 3 months. Results. Kappa was 0.84 for presence of abnormality versus a normal exam and 0.89 for differentiating active inflammation from chronic stricture. Level of agreement for presence of skip areas, abscess formation, and fistula was 0.62, 0.75, and 0.78, respectively. In the subset with “gold standard” follow-up, there was 83% agreement. Conclusions. MBCT is a low-radiation technique with good to very good interobserver agreement for determining presence of obstruction and degree of disease activity in patients with Crohn's disease. Further investigation is required to refine parameters of disease activity compared to CT enterography and small bowel follow through.

  11. Dynamic telecytologic evaluation of imprint cytology samples from CT-guided lung biopsies: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Prosch, Helmut [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Medical University of Vienna, Department of Radiology, Vienna (Austria); Medical University of Vienna, Vienna General Hospital, Department of Radiology, Vienna (Austria); Hoffmann, Elisabeth; Schober, Ewald; Mostbeck, Gerhard [Otto Wagner Hospital, Department of Radiology, Vienna (Austria); Bernhardt, Klaus; Schalleschak, Johann [Otto Wagner Hospital, Department of Laboratory Medicine, Vienna (Austria); Rowhani, Marcel [Otto Wagner Hospital, Department of Respiratory and Critical Care Medicine, Vienna (Austria); Weber, Michael [Medical University of Vienna, Department of Radiology, Vienna (Austria)

    2011-09-15

    This study assessed the feasibility of telecytological evaluation of samples from CT-guided lung biopsies using a dynamic telecytological system in which the microscope was operated by personnel from the radiology department at the site of the biopsy and a cytologist off-site diagnosed the biopsy sample. 45 imprint samples from CT-guided biopsies of lung lesions were reviewed by two cytologists using a telecytological microscope (Olympus BX51, Tokyo, Japan). The telecytological microscope was operated by one radiologist and one radiology technician. The cytological samples were classified by a cytologist into four categories: benign, malignant, atypical cells of undetermined significance, and non-diagnostic. The results were compared with those of a previous consensus reading of two independent cytologists (gold standard). When the radiologist was operating the microscope, the diagnostic accuracy was 100% as both cytologists came to the correct diagnosis in all samples. When the technician operated the microscope, two diagnoses of cyotologist 1 differed from the gold standard. Thus, the accuracy for the technician was 95.56%. Telecytological evaluation of imprint samples from CT-guided lung biopsies is feasible because it can be performed with high diagnostic accuracy if personnel from the radiology department operate the microscope. (orig.)

  12. Evaluation of image quality and dose on a flat-panel CT-scanner

    Science.gov (United States)

    Grasruck, M.; Suess, Ch.; Stierstorfer, K.; Popescu, S.; Flohr, T.

    2005-04-01

    We developed and evaluated a prototype flat-panel detector based Volume CT (VCT) scanner. We focused on improving the image quality using different detector settings and reducing x-ray scatter intensities. For the presented results we used a Varian 4030CB flat-panel detector mounted in a multislice CT-gantry (Siemens Medical Systems). The scatter intensities may severely impair image quality in flat-panel detector CT systems. To reduce the impact of scatter we tested bowtie shaped filters, anti-scatter grids and post-processing correction algorithms. We evaluated the improvement of image quality by each method and also by a combination of the several methods. To achieve an extended dynamic range in the projection data, we implemented a novel dynamic gain-switching mode. The read out charge amplifier feedback capacitance is changing dynamically in this mode, depending on the signal level. For this scan mode dedicated corrections in the offset and gain calibration are required. We compared image quality in terms of low contrast for both, the dynamic mode and the standard fixed gain mode. VCT scanners require different types of dose parameters. We measured the dose in a 16 cm CTDI phantom and free air in the scanners iso-center and defined a new metric for a VCT dose index (VCTDI). The dose for a high quality VCT scan of this prototype scanner varied between 15 and 40 mGy.

  13. An evaluation of three commercially available metal artifact reduction methods for CT imaging

    Science.gov (United States)

    Huang, Jessie Y.; Kerns, James R.; Nute, Jessica L.; Liu, Xinming; Balter, Peter A.; Stingo, Francesco C.; Followill, David S.; Mirkovic, Dragan; Howell, Rebecca M.; Kry, Stephen F.

    2015-02-01

    Three commercial metal artifact reduction methods were evaluated for use in computed tomography (CT) imaging in the presence of clinically realistic metal implants: Philips O-MAR, GE’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI monochromatic imaging with metal artifact reduction software applied (MARs). Each method was evaluated according to CT number accuracy, metal size accuracy, and streak artifact severity reduction by using several phantoms, including three anthropomorphic phantoms containing metal implants (hip prosthesis, dental fillings and spinal fixation rods). All three methods showed varying degrees of success for the hip prosthesis and spinal fixation rod cases, while none were particularly beneficial for dental artifacts. Limitations of the methods were also observed. MARs underestimated the size of metal implants and introduced new artifacts in imaging planes beyond the metal implant when applied to dental artifacts, and both the O-MAR and MARs algorithms induced artifacts for spinal fixation rods in a thoracic phantom. Our findings suggest that all three artifact mitigation methods may benefit patients with metal implants, though they should be used with caution in certain scenarios.

  14. Clinical evaluation of automatic tube voltage selection in chest CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Tilo; Henry, Simon; Faivre, Jean-Baptiste; Yasunaga, Kanna; Bendaoud, Sofiane; Simeone, Ariana; Remy, Jacques [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain [University Lille Nord de France, Department of Medical Statistics (EA 2694), Lille (France); Flohr, Thomas [Siemens Medical Systems, Department of Research and Development, Forchheim (Germany); Remy-Jardin, Martine [Hospital Calmette, Department of Thoracic Imaging, Lille cedex (France)

    2013-10-15

    To evaluate the clinical impact of automatic tube voltage selection on chest CT angiography (CTA). Ninety-three patients were prospectively evaluated with a CT protocol aimed at comparing two successive CTAs acquired under similar technical conditions except for the kV selection: (1) the initial CTA was systematically obtained at 120 kVp and 90 ref mAs; (2) the follow-up CTA was obtained with an automatic selection of the kilovoltage (Care KV; Siemens Healthcare) for optimised CTA. At follow-up, 90 patients (97 %) underwent CTA with reduced tube voltage, 100 kV (n = 26; 28 %) and 80 kV (n = 64; 69 %), resulting in a significant dose-length-product reduction (follow-up: 87.27; initial: 141.88 mGy.cm; P < 0.0001; mean dose reduction: 38.5 %) and a significant increase in the CNR at follow-up (follow-up: 11.5 {+-} 3.5 HU; initial: 10.9 {+-} 3.7 HU; P = 0.03). The increase in objective image noise at follow-up (follow-up: 23.2 {+-} 6.7 HU vs. 17.8 {+-} 5.1 HU; P < 0.0001) did not alter the diagnostic value of images. Automatic tube voltage selection reduced the radiation dose delivered during chest CT angiograms by 38.5 % while improving the contrast-to-noise ratio of the examinations. (orig.)

  15. Accuracy of the AAST organ injury scale for CT evaluation of traumatic liver and spleen injuries

    Directory of Open Access Journals (Sweden)

    Homann Georg

    2014-02-01

    Full Text Available 【Abstract】Objective: Detection of abdominal injury is a very important component in trauma management, so a precise assessment of liver and spleen injuries including their severity degree is necessary. There is a good case to believe that in emergency situations the radiologists’ performance may profit from a systematic approach using established scoring systems. Score systems as the organ injury scale (OIS drawn up by the American Association for the Surgery of Trauma are a valuable guidance for objective trauma assessment. Aim of this study was to evaluate retrospectively whether a structured approach using the OIS may help improve trauma assessment. Methods: Fifty-three patients, 38 male and 15 female who underwent CT and laparotomy after abdominal trauma were included in this study. The laparotomy was performed by experienced surgeons with a minimum experience of 6 years. While the original CT reports were written by different radiologists with a minimum experience of 3 years, and then a radiologist with experience of 4 years reviewed the same original CT pictures, resulting in the structured report. Both the original and structured CT results on liver and spleen injuries were transferred into OIS grades. Finally, the initial and structured CT results were compared with the intraoperative findings gathered from the surgery report. Results: Regarding the original CT report we found a mean divergence of 0.68±0.8 (r=0.45 to the OIS finding in the surgery report for liver injuries (0.69±1.17 for spleen injuries; r=0.69. In comparison with the structured approach, where we detected a divergence of 0.8±0.68; r=0.63 (0.47±0.77 for spleen injuries; r=0.91, there was no significant difference. However we detected a lower rate of over-diagnosis in structured approaches. Conclusion: Our study shows that a structured approach to triage abdominal trauma using an imaging check- list does not lead to a significantly higher detection rate, but a

  16. Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Li, Kuncheng, E-mail: cjr.likuncheng@vip.163.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Han, Ruijuan [Department of Cardiology, Chaoyang Hospital, Capital Medical University, Beijing 100020 (China); Li, Wenhuan; Chen, Nan; Yang, Qi; Du, Xiangying; Wang, Chen [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Liu, Guorong; Li, Yuechun [Department of Neurology Baotou Central Hospital, Inner Mongolia, Baotou 014040 (China); Zhou, Maorong [Department of Radiology, Baotou Central Hospital, Inner Mongolia, Baotou 014040 (China); Li, Ligang; Heidrun, Endt [CT BM Clinic Marketing, Siemens Healthcare, Beijing 100102 (China)

    2015-03-15

    Objectives: To explore the feasibility and diagnostic accuracy of a combined one-step high-pitch dual-source computed tomography angiography (CTA) technique for evaluation of coronary and carotid-cerebrovascular arteries. Materials and methods: 85 symptomatic patients suspected of coronary artery and cerebrovascular disease referred for simultaneous coronary and carotid-cerebrovascular CTA were included. Additional invasive angiography of the coronary and cerebral arteries was performed within 30 days in 23 and 13 patients, respectively. The objective parameters of image quality, the mean CT attenuations, image noise, signal-to-noise ratio