WorldWideScience

Sample records for ct electronic resource

  1. The Primary Care Electronic Library: RSS feeds using SNOMED-CT indexing for dynamic content delivery.

    Science.gov (United States)

    Robinson, Judas; de Lusignan, Simon; Kostkova, Patty; Madge, Bruce; Marsh, A; Biniaris, C

    2006-01-01

    Rich Site Summary (RSS) feeds are a method for disseminating and syndicating the contents of a website using extensible mark-up language (XML). The Primary Care Electronic Library (PCEL) distributes recent additions to the site in the form of an RSS feed. When new resources are added to PCEL, they are manually assigned medical subject headings (MeSH terms), which are then automatically mapped to SNOMED-CT terms using the Unified Medical Language System (UMLS) Metathesaurus. The library is thus searchable using MeSH or SNOMED-CT. Our syndicate partner wished to have remote access to PCEL coronary heart disease (CHD) information resources based on SNOMED-CT search terms. To pilot the supply of relevant information resources in response to clinically coded requests, using RSS syndication for transmission between web servers. Our syndicate partner provided a list of CHD SNOMED-CT terms to its end-users, a list which was coded according to UMLS specifications. When the end-user requested relevant information resources, this request was relayed from our syndicate partner's web server to the PCEL web server. The relevant resources were retrieved from the PCEL MySQL database. This database is accessed using a server side scripting language (PHP), which enables the production of dynamic RSS feeds on the basis of Source Asserted Identifiers (CODEs) contained in UMLS. Retrieving resources using SNOMED-CT terms using syndication can be used to build a functioning application. The process from request to display of syndicated resources took less than one second. The results of the pilot illustrate that it is possible to exchange data between servers using RSS syndication. This method could be utilised dynamically to supply digital library resources to a clinical system with SNOMED-CT data used as the standard of reference.

  2. Webwatch: An information resource for CT

    International Nuclear Information System (INIS)

    McEntee, Mark

    2007-01-01

    The World Wide Web is a fantastic resource for information. It is often the first place that students and Radiographers alike will turn to when looking for information. This paper draws attention to several websites of interest while mainly concentrating on one website with an abundance of information for Healthcare Professional working in CT. Although this website uses a lot of information from the equipment manufacturers' guidelines, it is a very useful resource with many clinical tips. CT is us is a large website that can sometimes be a little difficult to navigate. The streaming of video lectures brings content alive, while the frequent updates and the interactivity of the feedback session make it worth a visit

  3. Electronic noise in CT detectors: Impact on image noise and artifacts.

    Science.gov (United States)

    Duan, Xinhui; Wang, Jia; Leng, Shuai; Schmidt, Bernhard; Allmendinger, Thomas; Grant, Katharine; Flohr, Thomas; McCollough, Cynthia H

    2013-10-01

    The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.

  4. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  5. Variance analysis of x-ray CT sinograms in the presence of electronic noise background.

    Science.gov (United States)

    Ma, Jianhua; Liang, Zhengrong; Fan, Yi; Liu, Yan; Huang, Jing; Chen, Wufan; Lu, Hongbing

    2012-07-01

    Low-dose x-ray computed tomography (CT) is clinically desired. Accurate noise modeling is a fundamental issue for low-dose CT image reconstruction via statistics-based sinogram restoration or statistical iterative image reconstruction. In this paper, the authors analyzed the statistical moments of low-dose CT data in the presence of electronic noise background. The authors first studied the statistical moment properties of detected signals in CT transmission domain, where the noise of detected signals is considered as quanta fluctuation upon electronic noise background. Then the authors derived, via the Taylor expansion, a new formula for the mean-variance relationship of the detected signals in CT sinogram domain, wherein the image formation becomes a linear operation between the sinogram data and the unknown image, rather than a nonlinear operation in the CT transmission domain. To get insight into the derived new formula by experiments, an anthropomorphic torso phantom was scanned repeatedly by a commercial CT scanner at five different mAs levels from 100 down to 17. The results demonstrated that the electronic noise background is significant when low-mAs (or low-dose) scan is performed. The influence of the electronic noise background should be considered in low-dose CT imaging.

  6. Investigation of bulk electron densities for dose calculations on cone-beam CT images

    International Nuclear Information System (INIS)

    Lambert, J.; Parker, J.; Gupta, S.; Hatton, J.; Tang, C.; Capp, A.; Denham, J.W.; Wright, P.

    2010-01-01

    Full text: If cone-beam CT images are to be used for dose calculations, then the images must be able to provide accurate electron density information. Twelve patients underwent twice weekly cone-beam CT scans in addition to the planning CT scan. A standardised 5-field treatment plan was applied to 169 of the CBCT images. Doses were calculated using the original electron density values in the CBCT and with bulk electron densities applied. Bone was assigned a density of 288 HU, and all other tissue was assigned to be water equivalent (0 HU). The doses were compared to the dose calculated on the original planning CT image. Using the original HU values in the cone-beam images, the average dose del i vered by the plans from all 12 patients was I. I % lower than the intended 200 cOy delivered on the original CT plans (standard devia tion 0.7%, maximum difference -2.93%). When bulk electron densities were applied to the cone-beam images, the average dose was 0.3% lower than the original CT plans (standard deviation 0.8%, maximum difference -2.22%). Compared to using the original HU values, applying bulk electron densities to the CBCT images improved the dose calculations by almost I %. Some variation due to natural changes in anatomy should be expected. The application of bulk elec tron densities to cone beam CT images has the potential to improve the accuracy of dose calculations due to inaccurate H U values. Acknowledgements This work was partially funded by Cancer Council NSW Grant Number RG 07-06.

  7. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  8. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  9. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  10. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  11. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  12. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  13. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Hsi, W-C; Ringor, Michael; Lu Xiaoyi

    2006-01-01

    Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity

  14. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  15. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  16. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  17. SU-E-J-43: Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT

    International Nuclear Information System (INIS)

    Mishra, K; Godley, A

    2014-01-01

    Purpose: To confirm that deforming the planning CT to the daily Cone-Beam CTs (CBCT) can provide suitable electron density for adaptive planning. We quantify the dosimetric difference between plans calculated on deformed planning CTs (DPCT) and daily CT-on-rails images (CTOR). CTOR is used as a test of the method as CTOR already contains accurate electron density to compare against. Methods: Five prostate only IMRT patients, each with five CTOR images, were selected and re-planned on Panther (Prowess Inc.) with a uniform 5 mm PTV expansion, prescribed 78 Gy. The planning CT was deformed to match each CTOR using ABAS (Elekta Inc.). Contours were drawn on the CTOR, and copied to the DPCT. The original treatment plan was copied to both the CTOR and DPCT, keeping the center of the prostate as the isocenter. The plans were then calculated using the collapsed cone heterogeneous dose engine of Prowess and typical DVH planning parameters used to compare them. Results: Each DPCT was visually compared to its CTOR with no differences observed. The agreement of the copied CTOR contours with the DPCT anatomy further demonstrated the deformation accuracy. The plans calculated using CTOR and DPCT were compared. Over the 25 plan pairs, the average difference between them for prostate D100, D98 and D95 were 0.5%, 0.2%, and 0.2%; PTV D98, D95 and mean dose: 0.3%, 0.2% and 0.3%; bladder V70, V60 and mean dose: 1.1%, 0.7%, and 0.2%; and rectum mean dose: 0.3%. (D100 is the dose covering 100% of the target; V70 is the volume of the organ receiving 70 Gy). Conclusion: We observe negligible difference between the dose calculated on the DPCT and the CTOR, implying that deformed planning CTs are a suitable substitute for electron density. The method can now be applied to CBCTs. Research version of Panther provided by Prowess Inc. Research version of ABAS provided by Elekta Inc

  18. SU-E-J-43: Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, K [Cleveland State University, Cleveland, OH (United States); Godley, A [Cleveland Clinic, Cleveland, OH (United States)

    2014-06-01

    Purpose: To confirm that deforming the planning CT to the daily Cone-Beam CTs (CBCT) can provide suitable electron density for adaptive planning. We quantify the dosimetric difference between plans calculated on deformed planning CTs (DPCT) and daily CT-on-rails images (CTOR). CTOR is used as a test of the method as CTOR already contains accurate electron density to compare against. Methods: Five prostate only IMRT patients, each with five CTOR images, were selected and re-planned on Panther (Prowess Inc.) with a uniform 5 mm PTV expansion, prescribed 78 Gy. The planning CT was deformed to match each CTOR using ABAS (Elekta Inc.). Contours were drawn on the CTOR, and copied to the DPCT. The original treatment plan was copied to both the CTOR and DPCT, keeping the center of the prostate as the isocenter. The plans were then calculated using the collapsed cone heterogeneous dose engine of Prowess and typical DVH planning parameters used to compare them. Results: Each DPCT was visually compared to its CTOR with no differences observed. The agreement of the copied CTOR contours with the DPCT anatomy further demonstrated the deformation accuracy. The plans calculated using CTOR and DPCT were compared. Over the 25 plan pairs, the average difference between them for prostate D100, D98 and D95 were 0.5%, 0.2%, and 0.2%; PTV D98, D95 and mean dose: 0.3%, 0.2% and 0.3%; bladder V70, V60 and mean dose: 1.1%, 0.7%, and 0.2%; and rectum mean dose: 0.3%. (D100 is the dose covering 100% of the target; V70 is the volume of the organ receiving 70 Gy). Conclusion: We observe negligible difference between the dose calculated on the DPCT and the CTOR, implying that deformed planning CTs are a suitable substitute for electron density. The method can now be applied to CBCTs. Research version of Panther provided by Prowess Inc. Research version of ABAS provided by Elekta Inc.

  19. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  20. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  1. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  2. use of electronic resources by graduate students of the department

    African Journals Online (AJOL)

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  3. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  4. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  5. Managing care pathways combining SNOMED CT, archetypes and an electronic guideline system.

    Science.gov (United States)

    Bernstein, Knut; Andersen, Ulrich

    2008-01-01

    Today electronic clinical guideline systems exist, but they are not well integrated with electronic health records. This paper thus proposes that the patient's "position" in the pathway during the patient journey should be made visible to all involved healthcare parties and the patient. This requires that the generic knowledge, which is represented in the guidelines, is combined with the patient specific information - and then made accessible for all relevant parties. In addition to the decision support provided by the guideline system documentation support can be provided by templates based on archetypes. This paper provides a proposal for how the guideline system and the EHR can be integrated by the use of archetypes and SNOMED CT. SNOMED CT provides the common reference terminology and the semantic links between the systems. The proposal also includes the use of a National Patient Index for storing data about the patient's position in the pathway and for sharing this information by all involved parties.

  6. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses ... CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed tomography, more commonly known ...

  7. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  8. Polyquant CT: direct electron and mass density reconstruction from a single polyenergetic source

    Science.gov (United States)

    Mason, Jonathan H.; Perelli, Alessandro; Nailon, William H.; Davies, Mike E.

    2017-11-01

    Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the x-ray attenuation in terms of mass or electron density is an ill-posed problem when a single polyenergetic source is used with a spectrally indiscriminate detector. Existing approaches to single source polyenergetic modelling often impose consistency with a physical model, such as water-bone or photoelectric-Compton decompositions, which will either require detailed prior segmentation or restrictive energy dependencies, and may require further calibration to the quantity of interest. In this work, we introduce a data centric approach to fitting the attenuation with piecewise-linear functions directly to mass or electron density, and present a segmentation-free statistical reconstruction algorithm for exploiting it, with the same order of complexity as other iterative methods. We show how this allows both higher accuracy in attenuation modelling, and demonstrate its superior quantitative imaging, with numerical chest and metal implant data, and validate it with real cone-beam CT measurements.

  9. Initial investigation into lower-cost CT for resource limited regions of the world

    Science.gov (United States)

    Dobbins, James T., III; Wells, Jered R.; Segars, W. Paul; Li, Christina M.; Kigongo, Christopher J. N.

    2010-04-01

    This paper describes an initial investigation into means for producing lower-cost CT scanners for resource limited regions of the world. In regions such as sub-Saharan Africa, intermediate level medical facilities serving millions have no CT machines, and lack the imaging resources necessary to determine whether certain patients would benefit from being transferred to a hospital in a larger city for further diagnostic workup or treatment. Low-cost CT scanners would potentially be of immense help to the healthcare system in such regions. Such scanners would not produce state-of-theart image quality, but rather would be intended primarily for triaging purposes to determine the patients who would benefit from transfer to larger hospitals. The lower-cost scanner investigated here consists of a fixed digital radiography system and a rotating patient stage. This paper describes initial experiments to determine if such a configuration is feasible. Experiments were conducted using (1) x-ray image acquisition, a physical anthropomorphic chest phantom, and a flat-panel detector system, and (2) a computer-simulated XCAT chest phantom. Both the physical phantom and simulated phantom produced excellent image quality reconstructions when the phantom was perfectly aligned during acquisition, but artifacts were noted when the phantom was displaced to simulate patient motion. An algorithm was developed to correct for motion of the phantom and demonstrated success in correcting for 5-mm motion during 360-degree acquisition of images. These experiments demonstrated feasibility for this approach, but additional work is required to determine the exact limitations produced by patient motion.

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  11. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  12. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  13. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen and Pelvis Computed tomography (CT) of the abdomen and pelvis is a ... is CT Scanning of the Abdomen/Pelvis? Computed tomography, more commonly known as a CT or CAT ...

  14. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Directory of Open Access Journals (Sweden)

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  15. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  16. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Directory of Open Access Journals (Sweden)

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  17. Preservation and conservation of electronic information resources of ...

    African Journals Online (AJOL)

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  18. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  19. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  20. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  1. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  2. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) ... are the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a ...

  4. Obtaining the conversion curve of CT numbers to electron density from the effective energy of the CT using the dummy SEFM

    International Nuclear Information System (INIS)

    Martin-Viera Cueto, J. A.; Garcia Pareja, S.; Benitez Villegas, E. M.; Moreno Saiz, E. M.; Bodineau Gil, C.; Caudepon Moreno, F.

    2011-01-01

    The objective of this work is to obtain the conversion curve of Hounsfield units (A) versus electron densities using a mannequin with different tissue equivalent materials. This provides for the effective energy beam CT and is used to characterize the linear coefficients of absorption of different materials that comprise the dummy.

  5. Indications for direct multidirectional or multiplanar electronic reconstructions in CT-scanning of the head

    International Nuclear Information System (INIS)

    Kaiser, M.C.; Veiga-Pires, J.A.; Gooskens, R.; Troost, J.

    1982-01-01

    The authors set out to indicate the optimal applications at minimum radiation penalty of both direct multidirectional and multiplanar electronic reconstruction modes in CT-scanning of the head by means of two illustrative case reports of midline congenital tumours. (orig.)

  6. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  7. Accuracy and efficiency of radiologists reporting CT studies from a multiscreen electronic workstation

    International Nuclear Information System (INIS)

    Foley, W.D.; Lawson, T.L.; Erickson, S.J.

    1988-01-01

    This paper describes a limited picture archiving communication system linking, a via fiber optic cable, two computed tomographic (CT) scanners, and a double-screen (1,000-line monitors) display station with a 600-megabyte image memory evaluated for accuracy and efficiency in the generation of a radiology report. Twenty preselected CT studies (an average of 30 images per study, ten with prior examination for comparison) in cases with pathologically or clinically proved diagnoses were read by five radiologists, in random order, from both the electronic display console and conventional multiformat images. All cases were reread after 1-month interval in a different random order viewing sequence and the opposite viewing modality

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses Computed tomography (CT) of the sinuses uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray equipment ... story here Images × Image Gallery Patient undergoing computed tomography (CT) scan. View full size with caption Pediatric Content ...

  10. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  11. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  12. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  13. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is ... a CT scan. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  14. CT angiography using electron-beam computed tomography (EBCT). A phantom study

    International Nuclear Information System (INIS)

    Uchino, Akira; Kato, Akira; Kudo, Sho

    1997-01-01

    The purpose of this study was to evaluate the accuracy of CT angiography in small vessels using electron-beam computed tomography (EBCT). Vessel phantoms with inner diameters of 8 mm, 6 mm, and 4 mm were prepared with segments of 75%, 50%, and 25% stenosis in each vessel. The vessels were filled with contrast medium (Iopamidol 300 at 1/24 dilution, approximately 380 HU). The EBCT apparatus used was an Imatron C-150. The step volume scan mode was used with slice thicknesses of 1.5 mm and 3.0 mm, scan time of 0.3 sec, and 210 mm field of view. Images with a slice thickness of 1.5 mm were definitely better than those with a slice thickness of 3.0 mm. The quality of maximum intensity projection (MIP) images was quite similar to that of three-dimensional (3D) images. Using the 8 mm vessel phantom, all stenotic segments were accurately visualized on CT angiography. The 50% stenotic segments were accurately estimated in all vessels. However, the 75% stenotic segments were slightly overestimated in smaller vessels, and the 25% stenotic segments were slightly underestimated in smaller vessels. We consider CT angiography using EBCT to be a useful, less invasive diagnostic modality for stenoocclusive lesions. (author)

  15. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  16. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  17. Why and How to Measure the Use of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  18. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  19. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Science.gov (United States)

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ...

  1. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... Image Gallery Patient undergoing computed tomography (CT) scan View full size with caption Pediatric Content Some imaging ...

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  4. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  5. Calibration of megavoltage cone-beam CT for radiotherapy dose calculations: Correction of cupping artifacts and conversion of CT numbers to electron density

    International Nuclear Information System (INIS)

    Petit, Steven F.; Elmpt, Wouter J. C. van; Nijsten, Sebastiaan M. J. J. G.; Lambin, Philippe; Dekker, Andre L. A. J.

    2008-01-01

    Megavoltage cone-beam CT (MV CBCT) is used for three-dimensional imaging of the patient anatomy on the treatment table prior to or just after radiotherapy treatment. To use MV CBCT images for radiotherapy dose calculation purposes, reliable electron density (ED) distributions are needed. Patient scatter, beam hardening and softening effects result in cupping artifacts in MV CBCT images and distort the CT number to ED conversion. A method based on transmission images is presented to correct for these effects without using prior knowledge of the object's geometry. The scatter distribution originating from the patient is calculated with pencil beam scatter kernels that are fitted based on transmission measurements. The radiological thickness is extracted from the scatter subtracted transmission images and is then converted to the primary transmission used in the cone-beam reconstruction. These corrections are performed in an iterative manner, without using prior knowledge regarding the geometry and composition of the object. The method was tested using various homogeneous and inhomogeneous phantoms with varying shapes and compositions, including a phantom with different electron density inserts, phantoms with large density variations, and an anthropomorphic head phantom. For all phantoms, the cupping artifact was substantially removed from the images and a linear relation between the CT number and electron density was found. After correction the deviations in reconstructed ED from the true values were reduced from up to 0.30 ED units to 0.03 for the majority of the phantoms; the residual difference is equal to the amount of noise in the images. The ED distributions were evaluated in terms of absolute dose calculation accuracy for homogeneous cylinders of different size; errors decreased from 7% to below 1% in the center of the objects for the uncorrected and corrected images, respectively, and maximum differences were reduced from 17% to 2%, respectively. The

  6. Electron-beam CT diagnosis of congenital cardiovascular diverticula

    International Nuclear Information System (INIS)

    Yang Youyou; Zheng Lili; Li Xiangmin; Zhou Xuhui; Peng Qian; Meng Quanfei; Dai Ruping

    2008-01-01

    Objective: To investigate the clinical application of electron-beam CT (EBCT) in the diagnosis of congenital cardiovascular diverticula. Methods: Retrospective analysis of 9 patients with congenital cardiovascular diverticula confirmed by operation and pathology was done. Of them, enhanced continuous volume scan was performed on 8 patients and enhanced single slice scan was performed on one patient with an Imatron C-150 scanner. Results: The group of 9 patients included one patient with diverticulum of the left ventricle, 3 patients with diverticulum of the atria and 5 patients with diverticulum of the aorta. EBCT scan and three dimensional reconstruction could demonstrate not only the origin, size, shape, location and adjacent structure of diverticula, but also other important complicated abnormalities such as ventriculoarterial connection disorder, cardiac septal defect, aortic coarctation and even dissection. Conclusion: EBCT is an ideal noninvasive technique in the diagnosis of congenital cardiovascular diverticula. (authors)

  7. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ... best for your child. top of page Additional Information and Resources The Alliance for Radiation Safety in ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  9. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  10. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... be viewed on a computer monitor, printed on film or transferred to a CD or DVD. CT ... distinguished from one another on an x-ray film or CT electronic image. In a conventional x- ...

  11. CT of calcaneal fractures: 3-D-reformations with electronic disarticulation

    International Nuclear Information System (INIS)

    Freund, M.; Hohendorff, B.; Zenker, W.; Hutzelmann, A.; Heller, M.

    1996-01-01

    25 patients with intra-articular calcaneal fractures underwent diagnostic CT-examinations. Axial slices, sagittal and 3-D-reformations with and without electronic disarticulation were performed. The sagittal and both types of 3-D-reformations were compared to the axial slices with regard to the diagnostic criteria: Involvement of articular facets, number of fragments, and traumatic changes of the hindfoot. The best proof of involvement of articular facets is found in axial slices and 3-D-reconstructions after disarticulation followed by sagittal reconstructions. Usually on 3-D-reconstructions without disarticulation articular facets cannot be identified because of overlapping bones. The number of fragments is clearly demonstrated by axial slices and sagittal reconstructions followed by 3-D-reconstructions after disarticulation. Traumatic changes of the hindfoot can be diagnosed in all four forms of visualisation. The decisive diagnosis for treatment planning is made based on the axial slices supported by sagittal reformations. In unclarified cases 3-D-reformations after electronic disarticulation may provide further information. 3-D-reformations without disarticulation are useless. (orig./MG) [de

  12. TH-CD-202-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY): Evaluation of the Use of Direct Electron Density CT Images in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, T; Sun, B; Li, H; Mutic, S [Washington University School of Medicine, St. Louis, MO (United States); Mistry, N [Siemens Healthcare, Cary, NC (United States); Raupach, R; Huenemohr, N; Ritter [Siemens Healthcare GmbH, Forchheim, Bavaria (Germany)

    2016-06-15

    Purpose: The current standard for calculation of photon and electron dose requires conversion of Hounsfield Units (HU) to Electron Density (ED) by applying a calibration curve specifically constructed for the corresponding CT tube voltage. This practice limits the use of the CT scanner to a single tube voltage and hinders the freedom in the selection of optimal tube voltage for better image quality. The objective of this study is to report a prototype CT reconstruction algorithm that provides direct ED images from the raw CT data independently of tube voltages used during acquisition. Methods: A tissue substitute phantom was scanned for Stoichiometric CT calibrations at tube voltages of 70kV, 80kV, 100kV, 120kV and 140kV respectively. HU images and direct ED images were acquired sequentially on a thoracic anthropomorphic phantom at the same tube voltages. Electron densities converted from the HU images were compared to ED obtained from the direct ED images. A 7-field treatment plan was made on all HU and ED images. Gamma analysis was performed to demonstrate quantitatively dosimetric change from the two schemes in acquiring ED. Results: The average deviation of EDs obtained from the direct ED images was −1.5%±2.1% from the EDs from HU images with the corresponding CT calibration curves applied. Gamma analysis on dose calculated on the direct ED images and the HU images acquired at the same tube voltage indicated negligible difference with lowest passing rate at 99.9%. Conclusion: Direct ED images require no CT calibration while demonstrate equivalent dosimetry compared to that obtained from standard HU images. The ability of acquiring direct ED images simplifies the current practice at a safer level by eliminating CT calibration and HU conversion from commissioning and treatment planning respectively. Furthermore, it unlocks a wider range of tube voltages in CT scanner for better imaging quality while maintaining similar dosimetric accuracy.

  13. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Directory of Open Access Journals (Sweden)

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  14. Essential requirements of a CT colonography service

    International Nuclear Information System (INIS)

    Hansmann, Anika; Burling, David

    2013-01-01

    There are many potential challenges to developing a high quality, efficient CT colonography service. Some are clear and predictable, for example creating CT capacity and securing financial resources, but some are less obvious, such as harnessing local support or changing referral practice amongst clinical colleagues. Notwithstanding, such barriers will need to be overcome to deliver a well-resourced, successful CT colonography programme. This article utilises the authors’ experience of developing their own CT colonography service from scratch (now examining >1200 patients per annum) and relevant published articles on ‘Standards’ of practice and training to recommend how others might provide CT colonography in their own patient communities. We offer a practical guide and will emphasise the need for a multi-disciplinary approach with locally agreed protocols and service objectives

  15. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  16. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  17. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  18. A survey of the use of electronic scientific information resources among medical and dental students

    Directory of Open Access Journals (Sweden)

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  19. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  20. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  1. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  2. Computed Tomography (CT) Scans and Cancer

    Science.gov (United States)

    ... Reporting & Auditing Grant Transfer Grant Closeout Contracts & Small Business Training Cancer Training at NCI (Intramural) Resources for ... companies (and Medicare) do not currently reimburse the costs of this procedure. Also, because CT ... the effectiveness of low-dose helical CT for lung cancer ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite each other ... another on an x-ray film or CT electronic image. In a conventional x-ray exam, a ...

  6. Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

    International Nuclear Information System (INIS)

    Owen, Rebecca; Kron, Tomas; Foroudi, Farshad; Milner, Alvin; Cox, Jennifer; Duchesne, Gillian; Cleeve, Laurence; Zhu Li; Cramb, Jim; Sparks, Laura; Laferlita, Marcus

    2009-01-01

    Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of ≤3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

  7. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  8. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  9. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    African Journals Online (AJOL)

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  10. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  11. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  12. PET/CT Biograph trademark Sensation 16. Performance improvement using faster electronics

    International Nuclear Information System (INIS)

    Martinez, M.J.; Schwaiger, M.; Ziegler, S.I.; Bercier, Y.

    2006-01-01

    Aim: the new PET/CT biograph sensation 16 (BS16) tomographs have faster detector electronics which allow a reduced timing coincidence window and an increased lower energy threshold (from 350 to 400 keV). This paper evaluates the performance of the BS16 PET scanner before and after the Pico-3D electronics upgrade. Methods: four NEMA NU 2-2001 protocols, (i) spatial resolution, (ii) scatter fraction, count losses and random measurement, (iii) sensitivity, and (iv) image quality, have been performed. Results: a considerable change in both PET count-rate performance and image quality is observed after electronics upgrade. The new scatter fraction obtained using Pico-3D electronics showed a 14% decrease compared to that obtained with the previous electronics. At the typical patient background activity (5.3 kBq/ml), the new scatter fraction was approximately 0.42. The noise equivalent count-rate (R NEC ) performance was also improved. The value at which the R NEC curve peaked, increased from 3.7 . 10 4 s -1 at 14 kBq/ml to 6.4 . 10 4 s -1 at 21 kBq/ml (2R-NEC rate). Likewise, the peak true count-rate value increased from 1.9 . 10 5 s -1 at 22 kBq/ml to 3.4 . 10 5 s -1 at 33 kBq/ml. An average increase of 45% in contrast was observed for hot spheres when using AW-OSEM (4ix8s) as the reconstruction algorithm. For cold spheres, the average increase was 12%. Conclusion: the performance of the PET scanners in the BS16 tomographs is improved by the optimization of the signal processing. The narrower energy and timing coincidence windows lead to a considerable increase of signal-to-noise ratio. The existing combination of fast detectors and adapted electronics in the BS16 tomographs allow imaging protocols with reduced acquisition time, providing higher patient throughput. (orig.)

  13. Initial observations of electronic medical record usage during CT and MRI interpretation: Frequency of use and impact on workflow.

    Science.gov (United States)

    Lin, Abraham; Harris, Mitchell; Zalis, Michael

    2010-07-01

    Electronic medical record (EMR) systems permit integration of contextual nonimaging EMR data into examination interpretation; however, the extra effort required to search and review these nonradiologic data are not well characterized. We assessed the gross frequency and pattern of EMR usage in the interpretation of diagnostic CT and MRI examinations. We defined nonradiologic EMR data as laboratory data, nonimaging specialty report, clinical note, and administrative data not available on PACS. For abdominal, neuroradiologic, and musculoskeletal CT and MRI, we prospectively recorded the time required for image analysis (including prior imaging studies and their reports), nonradiologic EMR use, and initial report drafting by fellows and staff in randomized sessions. We assessed EMR use as a fraction of work activity and according to technique, subspecialty, inpatient status, and radiologist experience. We observed 372 CT and MRI interpretations by 33 radiologists. For CT, radiologists used the EMR in 34% of abdominal, 57% of neuroradiologic, and 38% of musculoskeletal interpretations. For MRI, EMR was used in 73% of abdominal, 56% of neuroradiologic, and 33% of musculoskeletal interpretations. For CT, EMR usage comprised 18%, 14%, and 18% of diagnostic effort (image analysis plus EMR use) for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively; for MRI, EMR usage comprised 21%, 16%, and 15% of diagnostic effort for abdominal, neuroradiologic, and musculoskeletal interpretations, respectively. Frequency of EMR use was significantly greater for neuroradiology CT and abdominal MRI (p < 0.05, Fisher's test). EMR usage was not consistently related to inpatient status for CT or radiologist experience. For CT and MRI interpretation, EMR usage is frequent and comprises a significant fraction of diagnostic effort.

  14. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  15. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  16. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Science.gov (United States)

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  17. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  18. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Abdomen ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Sinuses ...

  1. Randomized Controlled Trial of Electronic Care Plan Alerts and Resource Utilization by High Frequency Emergency Department Users with Opioid Use Disorder

    Directory of Open Access Journals (Sweden)

    Niels Rathlev, MD

    2016-01-01

    Full Text Available Introduction: There is a paucity of literature supporting the use of electronic alerts for patients with high frequency emergency department (ED use. We sought to measure changes in opioid prescribing and administration practices, total charges and other resource utilization using electronic alerts to notify providers of an opioid-use care plan for high frequency ED patients. Methods: This was a randomized, non-blinded, two-group parallel design study of patients who had 1 opioid use disorder and 2 high frequency ED use. Three affiliated hospitals with identical electronic health records participated. Patients were randomized into “Care Plan” versus “Usual Care groups”. Between the years before and after randomization, we compared as primary outcomes the following: 1 opioids (morphine mg equivalents prescribed to patients upon discharge and administered to ED and inpatients; 2 total medical charges, and the numbers of; 3 ED visits, 4 ED visits with advanced radiologic imaging (computed tomography [CT] or magnetic resonance imaging [MRI] studies, and 5 inpatient admissions. Results: A total of 40 patients were enrolled. For ED and inpatients in the “Usual Care” group, the proportion of morphine mg equivalents received in the post-period compared with the pre-period was 15.7%, while in the “Care Plan” group the proportion received in the post-period compared with the pre-period was 4.5% (ratio=0.29, 95% CI [0.07-1.12]; p=0.07. For discharged patients in the “Usual Care” group, the proportion of morphine mg equivalents prescribed in the post-period compared with the pre-period was 25.7% while in the “Care Plan” group, the proportion prescribed in the post-period compared to the pre-period was 2.9%. The “Care Plan” group showed an 89% greater proportional change over the periods compared with the “Usual Care” group (ratio=0.11, 95% CI [0.01-0.092]; p=0.04. Care plans did not change the total charges, or, the numbers

  2. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... membranes covering the brain. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain ...

  3. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple ... for the moving table. top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head ...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder ... Send us your feedback Did you find the information you were looking for? Yes No Please type ...

  5. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation ... To locate a medical imaging or radiation oncology provider in your community, you can search the ACR- ...

  6. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for ... Tomography (CT) - Head Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  8. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Tomography (CT) - Sinuses Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  9. [Accurate 3D free-form registration between fan-beam CT and cone-beam CT].

    Science.gov (United States)

    Liang, Yueqiang; Xu, Hongbing; Li, Baosheng; Li, Hongsheng; Yang, Fujun

    2012-06-01

    Because the X-ray scatters, the CT numbers in cone-beam CT cannot exactly correspond to the electron densities. This, therefore, results in registration error when the intensity-based registration algorithm is used to register planning fan-beam CT and cone-beam CT. In order to reduce the registration error, we have developed an accurate gradient-based registration algorithm. The gradient-based deformable registration problem is described as a minimization of energy functional. Through the calculus of variations and Gauss-Seidel finite difference method, we derived the iterative formula of the deformable registration. The algorithm was implemented by GPU through OpenCL framework, with which the registration time was greatly reduced. Our experimental results showed that the proposed gradient-based registration algorithm could register more accurately the clinical cone-beam CT and fan-beam CT images compared with the intensity-based algorithm. The GPU-accelerated algorithm meets the real-time requirement in the online adaptive radiotherapy.

  10. CT of the heart

    International Nuclear Information System (INIS)

    Lipton, M.J.

    1986-01-01

    Advances based upon the detector elements instead of X-ray film have greatly increased the power of X-ray imaging. Computed tomography (CT) creates cross sectional rather than projected images. Recently, high speed CT devices have been developed for cardiovascular studies. The Cine-CT scanner employs a scanning electron beam deflected on an extended tungsten target ring. Fast scans of 50 millisecond exposures at multiple levels can provide information concerning blood flow in vessels and tissues, myocardial wall motion, valve integrity, coronary bypass graft patency and proximal coronary artery anatomy. Cine-CT dynamic scanning can also provide volume imaging with small quantities (0.05 - 1.5 ml/kg) of contrast medium administered via peripheral vein injections. Cine-CT provides simultaneous measurements of cardiac dimensions and function and is rapidly becoming a new tool for quantitating myocardial blood flow, cardiac chamber volumes and wall mechanics. The future outlook is very promising for this three-dimensional cine-CT technique with high spatial resolution. High speed CT should provide unique diagnostic information and as the technology continues to improve at a rapid speed, this new imaging modality could be a challenge for angiography. (Auth.)

  11. Imatron CT C100 presentation. Limits-advantages

    International Nuclear Information System (INIS)

    Molle, M.; Molle, S.; Hernigou, A.

    1994-01-01

    Principles of Electron Beam CT are described and compared to conventional CT. Fast acquisitions and a short exposure time are the major qualities of the machine. Despite of a lower spatial resolution than in mechanical CT it allows exploration of moving organs and especially morphological and dynamic heart studies. The new possibilities of the Continuous Volume Scanning seems to present a promising future outlook. (authors). 5 refs., 4 figs., 1 tab

  12. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... pancreatic, uterine or ovarian abnormalities, the evaluation and diagnosis with MRI may be preferable over CT scanning. top of page Additional Information and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation Therapy for Colorectal Cancer top of page ...

  13. Introduction of the Canadian CT Head Rule Reduces CT Scan Use ...

    African Journals Online (AJOL)

    amnesia or witnessed disorientation in a patient with a GCS score of 13–15 who has suffered a traumatic event, the evaluation of minor head injury using. Computerized Axial Tomography Scan of the Head. (CT-head) has remained controversial.(1,3). CT–head is expensive, time consuming, strenuous to human resource ...

  14. Anterior glenoid rim fracture: the value of helical CT with threedimensional reconstruction and electronic humeral disarticulation

    Directory of Open Access Journals (Sweden)

    Heverton César de Oliveira

    2003-06-01

    Full Text Available Objectives: To show a new three-dimensional reconstructiontechnique based on helical computed tomography images withelectronic humeral disarticulation in anterior glenoid rim fractures,correlating the anatomic specimen with simulation of an anteriorglenoid rim fracture, as well as evaluating the extension of thefracture, the bone fragment position and distance in relation to theglenoid cavity in six patients. Methods: One scapula and onehumerus with no signs of fracture or congenital malformationswere placed in anatomical position using an adhesive tape aftersimulating an anterior glenoid rim fracture made by an osteotome.Helical CT imaging was acquired and three-dimensionalreconstructions were made based on these images, with andwithout electronic humeral disarticulation. The bone fragment waslocated, measured and its position in relation to the glenoid cavitywas assessed. Six patients with anterior glenoid rim fracture weresubmitted to CT of the shoulder using the same parameters asthose applied to the anatomic specimen. Results: In the anatomicspecimen and in all six patients the bone fragment was clearlydemonstrated; bone fragment measurements in the anatomicspecimen and in three-dimensional reconstructions wereequivalent. The fragment was better demonstrated in the imagestaken with electronic humeral disarticulation, particularly in thefrontal view of the glenoid cavity as observed in all six patients.Conclusion: We concluded that our experiment with the anatomicspecimen and the study of six patients allow us to state that thistechnique is safe and accurate to demonstrate the extension, sizeand location of the bone fragment in anterior glenoid rim fractures,and it provides essential elements for therapeutic planning.

  15. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Children's (Pediatric) CT (Computed ...

  16. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  17. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  18. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... your child. top of page Additional Information and Resources The Alliance for Radiation Safety in Pediatric Imaging's " ... A child being prepared for a CT scan. View full size with caption Pediatric Content Some imaging ...

  19. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  20. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... and Resources RTAnswers.org: Radiation Therapy for Bladder Cancer Radiation Therapy for Colorectal Cancer top of page This page was reviewed on ... with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. ... Images related to Computed Tomography (CT) - Abdomen and ...

  1. A randomised clinical trial of routine versus selective CT imaging in acute abdomen: Impact of patient age on treatment costs and hospital resource use

    Energy Technology Data Exchange (ETDEWEB)

    Lehtimäki, Tiina T., E-mail: tiina.lehtimaki@kuh.fi [Department of Clinical Radiology, Kuopio University Hospital, Puijonlaaksontie 2, FI-70210, Kuopio (Finland); Valtonen, Hannu, E-mail: hannu.valtonen@uef.fi [University of Eastern Finland, Department of Health and Social Management, Yliopistonranta 1, FI-70211 Kuopio (Finland); Miettinen, Pekka, E-mail: pekka.miettinen@satucon.fi [Department of Gastrointestinal Surgery, Kuopio University Hospital, Puijonlaaksontie 2, FI-70210 Kuopio (Finland); Juvonen, Petri, E-mail: petri.juvonen@kuh.fi [Department of Gastrointestinal Surgery, Kuopio University Hospital, Puijonlaaksontie 2, FI-70210 Kuopio (Finland); Paajanen, Hannu, E-mail: hannu.paajanen@kuh.fi [Department of Gastrointestinal Surgery, Kuopio University Hospital, Puijonlaaksontie 2, FI-70210 Kuopio (Finland); University of Eastern Finland, Department of Clinical Medicine, Unit of Surgery, Yliopistonranta 1, FI-70211 Kuopio (Finland); Vanninen, Ritva, E-mail: ritva.vanninen@kuh.fi [Department of Clinical Radiology, Kuopio University Hospital, Puijonlaaksontie 2, FI-70210, Kuopio (Finland); University of Eastern Finland, Department of Clinical Medicine, Unit of Radiology, Yliopistonranta 1, FI-70211 Kuopio (Finland)

    2017-02-15

    Objectives: To evaluate the impact of patient age on hospital resource use and treatment costs of acute abdominal pain (AAP). Materials and methods: A total of 300 adult patients with AAP were randomised to either computed tomography (CT, n = 150) or selective imaging practice (SIP, n = 150) groups. Final analysis included 254 patients, 143 (42 patients ≥65 years) in the CT and 111 (32 patients ≥65 years) in the SIP group. All CT group patients underwent abdominal CT whereas in the SIP group, imaging was based on the clinical assessment. For each patient, the hospital length of stay (LOS), the numbers and costs of diagnostic and treatment procedures arising from AAP were calculated and registered. The incremental cost-effectiveness ratio (ICER) and bootstrapped cost-effectiveness acceptability curve (CEAC) were estimated for routine CT. Results: Treatment costs, imaging costs and LOS increased in conjunction with aging in both study groups, and were generally higher in the CT group compared to the SIP group. In the SIP group, CT was undertaken in 34% (27/79) of the <65 year olds but in 59% (19/32) of the older patients (≥65 years) (p = 0.02). The proportion of patients with non-specific abdominal pain was significantly lower in patients ≥65 years than in their younger counterparts (p = 0.04). In the routine CT group, the ICER of obtaining a specific diagnosis was 1682 € for patients <65 years and 1055 € for patients ≥65 years. According to CEAC estimation, routine CT for every patient with AAP has a 95% probability of being cost-effective if society is willing to pay 14087 € for an additional specific diagnosis for patients <65 years but only 4204 € in those ≥65 years. Conclusion: Treatment costs of AAP increase in parallel with aging, and the costs are generally higher with routine CT compared to selective imaging. The probability of obtaining a specific diagnosis of AAP increases with aging. If obtaining a specific diagnosis is deemed crucial

  2. Correction of conebeam CT values using a planning CT for derivation of the 'dose of the day'

    International Nuclear Information System (INIS)

    Zijtveld, Mathilda van; Dirkx, Maarten; Heijmen, Ben

    2007-01-01

    Background and purpose: Verification of the actually delivered 3D dose distribution during each treatment fraction ('dose of the day') is the most complete and clinical relevant 'in-vivo' check of an IMRT treatment. To do this, during patient treatment portal dose images are routinely acquired with our electronic portal imaging device to derive the delivered fluence map for each treatment field. In addition, a conebeam CT scan is acquired just prior to treatment to derive the patient geometry at the time of treatment. However, the use of conebeam CT scans for dose calculation is hampered by inaccuracies in the conversion of CT values to electron densities due to an enlarged scatter contribution. Materials and methods: In this work, a method is described for mapping of Hounsfield Units of the planning CT to the conebeam CT scan, while accounting for non-rigidity in the anatomy, e.g. related to weight loss, in an approximate way. The method was validated for head and neck cancer patients by comparing dose distributions calculated using adjusted Hounsfield Units with a golden standard. Results and conclusions: The observed dose differences were less than 1% in the majority of points, and in at least 96% of the points a 3D γ analysis resulted in γ values of less than 1 when applying a 2%/2 mm criterion, showing that this straightforward approach allows for an accurate dose calculation based on conebeam CT scans

  3. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CD or DVD. CT images of internal organs, bones, soft tissue and blood vessels provide greater detail ... image on a special electronic image recording plate. Bones appear white on the x-ray; soft tissue, ...

  4. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

    International Nuclear Information System (INIS)

    2011-01-01

    Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process. Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule≥3 mm,''''nodule<3 mm,'' and ''non-nodule≥3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked ''nodule≥3 mm'' by at least one radiologist, of which 928 (34.7%) received such marks from all

  5. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    OpenAIRE

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  6. Cine-CT: A new technique in X-ray computed tomography

    International Nuclear Information System (INIS)

    Jaschke, W.; Georgi, M.; Lipton, M.J.; Gould, R.G.

    1988-01-01

    The 'Cine-CT' belongs to a new generation of CT devices permitting not only diagnostics on a morphological basis but also function studies. By means of Cine-CT's electron beam technique, image frequencies of up to 17 images per second and exposure times of 50 msec are possible. (orig.) [de

  7. Assessment of coronary artery stent patency by electron-beam CT

    International Nuclear Information System (INIS)

    Knollmann, Friedrich D.; Felix, Roland; Moeller, Joerg; Gebert, Axel; Bethge, Christian

    2004-01-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  8. Assessment of coronary artery stent patency by electron-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Knollmann, Friedrich D.; Felix, Roland [Department of Radiology, Charite, Campus Virchow-Klinikum, Humboldt-University, Augustenburger Platz 1, 13353, Berlin (Germany); Moeller, Joerg; Gebert, Axel; Bethge, Christian [Department of Cardiology, Juedisches Krankenhaus, Berlin (Germany)

    2004-08-01

    Following coronary angioplasty and stent implantation, restenosis remains common and its outcome difficult to predict. We set out to determine the diagnostic accuracy of electron-beam computed tomography (EBCT) for the non-invasive detection of stent obstruction. In a prospective, blinded investigation, we included 152 coronary artery segments in 117 patients treated with a stent implant. All segments were evaluated by a dynamic EBCT study that depicted contrast bolus passage distal to the stent and a CT angiographic study of the entire coronary arteries. It was found that delayed contrast enhancement in the distal segment correlated with angiographic stent obstruction (Spearman's rank correlation, P=0.008), while all other indicators of stent occlusion did not correlate with angiographic diagnosis. However, direct comparison of patients with obstruction of less vs. more than 75% of luminal diameter did not yield any statistically significant differences of distal enhancement delay, and for the detection of >90% occlusion, the sensitivity was 72% at a specificity of 60%. Although delayed contrast enhancement distal to the stent upon EBCT did correlate with angiographical obstruction, the correlation did not suffice to appear clinically satisfactory. (orig.)

  9. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Science.gov (United States)

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  10. CT applications of medical computer graphics

    International Nuclear Information System (INIS)

    Rhodes, M.L.

    1985-01-01

    Few applications of computer graphics show as much promise and early success as that for CT. Unlike electron microscopy, ultrasound, business, military, and animation applications, CT image data are inherently digital. CT pictures can be processed directly by programs well established in the fields of computer graphics and digital image processing. Methods for reformatting digital pictures, enhancing structure shape, reducing image noise, and rendering three-dimensional (3D) scenes of anatomic structures have all become routine at many CT centers. In this chapter, the authors provide a brief introduction to computer graphics terms and techniques commonly applied to CT pictures and, when appropriate, to those showing promise for magnetic resonance images. Topics discussed here are image-processing options that are applied to digital images already constructed. In the final portion of this chapter techniques for ''slicing'' CT image data are presented, and geometric principles that describe the specification of oblique and curved images are outlined. Clinical examples are included

  11. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Science.gov (United States)

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  12. Study on broad beam heavy ion CT

    International Nuclear Information System (INIS)

    Ohno, Yumiko; Kohno, Toshiyuki; Sasaki, Hitomi; Nanbu, S.; Kanai, Tatsuaki

    2003-01-01

    To achieve the heavy ion radiotherapy more precisely, it is important to know the distribution of the electron density in a human body, which is highly related to the range of charged particles. From a heavy ion CT image, we can directly obtain the 2-D distribution of the electron density in a sample. For this purpose, we have developed a broad beam heavy ion CT system. The electron density was obtained using some kinds of solutions targets. Also the dependence of the spatial resolution on the target size and the kinds of beams was estimated in this work using cylinders targets of 40, 60 and 80 mm in diameter, each of them has a hole of 10 mm in diameter at the center of it. (author)

  13. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  14. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Science.gov (United States)

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  15. Reliability and error analysis on xenon/CT CBF

    International Nuclear Information System (INIS)

    Zhang, Z.

    2000-01-01

    This article provides a quantitative error analysis of a simulation model of xenon/CT CBF in order to investigate the behavior and effect of different types of errors such as CT noise, motion artifacts, lower percentage of xenon supply, lower tissue enhancements, etc. A mathematical model is built to simulate these errors. By adjusting the initial parameters of the simulation model, we can scale the Gaussian noise, control the percentage of xenon supply, and change the tissue enhancement with different kVp settings. The motion artifact will be treated separately by geometrically shifting the sequential CT images. The input function is chosen from an end-tidal xenon curve of a practical study. Four kinds of cerebral blood flow, 10, 20, 50, and 80 cc/100 g/min, are examined under different error environments and the corresponding CT images are generated following the currently popular timing protocol. The simulated studies will be fed to a regular xenon/CT CBF system for calculation and evaluation. A quantitative comparison is given to reveal the behavior and effect of individual error resources. Mixed error testing is also provided to inspect the combination effect of errors. The experiment shows that CT noise is still a major error resource. The motion artifact affects the CBF results more geometrically than quantitatively. Lower xenon supply has a lesser effect on the results, but will reduce the signal/noise ratio. The lower xenon enhancement will lower the flow values in all areas of brain. (author)

  16. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Science.gov (United States)

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  17. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  18. Characteristics of modified CT injector for JFT-2M

    Energy Technology Data Exchange (ETDEWEB)

    Fukumoto, N. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan)]. E-mail: fukumoto@elct.eng.himeji-tech.ac.jp; Ogawa, H. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Nagata, M. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan); Uyama, T. [Himeji Institute of Technology, 2167 Shosha, Himeji, Hyogo 671-2201 (Japan); Shibata, T. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Kashiwa, Y. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan); Kusama, Y. [Japan Atomic Energy Research Institute (JAERI), 2-4 Shirakatashirane, Tokai-mura, Naka-gun, Ibaraki 311-0193 (Japan)

    2004-10-01

    The HIT-CTI mark II compact toroid (CT) injector employed for the JFT-2M tokamak facility at the Japan Atomic Energy Research Institute (JAERI) has been upgraded to improve injection performance. The nozzle of the mark III injector now has a linear tube in place of the original focus cone to avoid rapid focus and deceleration, and the tapered outer electrode has been replaced with more gentle taper in the compression section in order to facilitate gradual compression. The dependence of CT velocity and electron density on poloidal bias flux and trigger time of CT acceleration have been investigated in the operable range of 70-230 km/s average CT velocity and electron density of 0.1-1.0 x 10{sup 22} m{sup -3} at an accelerator bank voltage of 25 kV. The operation window is broader than that of the mark II injector. Emission of a CT plasmoid from the injector, and transport to the flux conserver as a high-density spheromak magnetic structure have also been confirmed.

  19. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  20. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... like? The CT scanner is typically a large machine with a hole, or short tunnel, in the ... of this tunnel. In the center of the machine, the x-ray tube and electronic x-ray ...

  2. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI): A Completed Reference Database of Lung Nodules on CT Scans

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-02-15

    Purpose: The development of computer-aided diagnostic (CAD) methods for lung nodule detection, classification, and quantitative assessment can be facilitated through a well-characterized repository of computed tomography (CT) scans. The Lung Image Database Consortium (LIDC) and Image Database Resource Initiative (IDRI) completed such a database, establishing a publicly available reference for the medical imaging research community. Initiated by the National Cancer Institute (NCI), further advanced by the Foundation for the National Institutes of Health (FNIH), and accompanied by the Food and Drug Administration (FDA) through active participation, this public-private partnership demonstrates the success of a consortium founded on a consensus-based process. Methods: Seven academic centers and eight medical imaging companies collaborated to identify, address, and resolve challenging organizational, technical, and clinical issues to provide a solid foundation for a robust database. The LIDC/IDRI Database contains 1018 cases, each of which includes images from a clinical thoracic CT scan and an associated XML file that records the results of a two-phase image annotation process performed by four experienced thoracic radiologists. In the initial blinded-read phase, each radiologist independently reviewed each CT scan and marked lesions belonging to one of three categories (''nodule{>=}3 mm,''''nodule<3 mm,'' and ''non-nodule{>=}3 mm''). In the subsequent unblinded-read phase, each radiologist independently reviewed their own marks along with the anonymized marks of the three other radiologists to render a final opinion. The goal of this process was to identify as completely as possible all lung nodules in each CT scan without requiring forced consensus. Results: The Database contains 7371 lesions marked ''nodule'' by at least one radiologist. 2669 of these lesions were marked &apos

  3. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  4. Better Collaborative Working is Likely to Increase Uptake of Library Resources in a University Setting. A review of: Hightower, Barbara, Carolyn Rawl, and Michelle Schutt. “Collaborations for Delivering the Library to Students Through WebCT.” Reference Services Review 35.4 (2007: 541-51.

    Directory of Open Access Journals (Sweden)

    John Loy

    2008-06-01

    Full Text Available Objectives – To ascertain the extent to which university faculty members are integrating library resources within the WebCT course management system / managed learning environment. Also, to identify the reasons why faculty members are not integrating library resources within WebCT, and to explore their willingness to do so in future. Design – Case study with survey questionnaire and selected interview follow up.Setting – Urban campus of Auburn University in Montgomery, Alabama, United States of America.Subjects – One hundred and two members of faculty received a questionnaire. Five follow-up interviews were conducted.Methods – One hundred and two members of faculty with WebCT-supported courses received a questionnaire. They were asked to indicate if they linked to library resources, and if so which specific ones (e.g. library homepage, online catalogue, etc.. If they did not link to library resources they were asked to indicate the reason why not, either by selecting one or more of five pre-selected reasons, or by detailing their own. Follow-up interviews were conducted with five respondents, two of whom (Education and Nursing linked to library resources, and three of whom (from Business, Education and Science did not. Server log reports were also examined to identify how many students were entering library resources from WebCT.Main Results – The survey response rate was 28% (29 individuals, and of these Nursing and Sciences were the highest users with 7 individuals in each faculty. Of the 29 respondents only 7 (24% currently linked to library resources. Nursing were the biggest group with 10 links (38% of the total, Science with 6 (23% and 5 each from Liberal Arts and Education (19%. The resources chosen to link to were• Article databases (6• Library homepage (5• Ask a Librarian e-mail service(3• Net library e-book collection (3Six other library resources scored lower and two were not linked to at all. While few respondents

  5. In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography (CT) and Light Microscopy (LM) Correlated with Scanning Electron Microscopy (SEM).

    Science.gov (United States)

    Meyer, Jörg; Thomas, Christian; Tappe, Frank; Ogbazghi, Tekie

    2016-06-16

    In failure analysis, device characterization and reverse engineering of light emitting diodes (LEDs), and similar electronic components of micro-characterization, plays an important role. Commonly, different techniques like X-ray computed tomography (CT), light microscopy (LM) and scanning electron microscopy (SEM) are used separately. Similarly, the results have to be treated for each technique independently. Here a comprehensive study is shown which demonstrates the potentials leveraged by linking CT, LM and SEM. In depth characterization is performed on a white emitting LED, which can be operated throughout all characterization steps. Major advantages are: planned preparation of defined cross sections, correlation of optical properties to structural and compositional information, as well as reliable identification of different functional regions. This results from the breadth of information available from identical regions of interest (ROIs): polarization contrast, bright and dark-field LM images, as well as optical images of the LED cross section in operation. This is supplemented by SEM imaging techniques and micro-analysis using energy dispersive X-ray spectroscopy.

  6. Content analysis of physical examination templates in electronic health records using SNOMED CT.

    Science.gov (United States)

    Gøeg, Kirstine Rosenbeck; Chen, Rong; Højen, Anne Randorff; Elberg, Pia

    2014-10-01

    Most electronic health record (EHR) systems are built on proprietary information models and terminology, which makes achieving semantic interoperability a challenge. Solving interoperability problems requires well-defined standards. In contrast, the need to support clinical work practice requires a local customization of EHR systems. Consequently, contrasting goals may be evident in EHR template design because customization means that local EHR organizations can define their own templates, whereas standardization implies consensus at some level. To explore the complexity of balancing these two goals, this study analyzes the differences and similarities between templates in use today. A similarity analysis was developed on the basis of SNOMED CT. The analysis was performed on four physical examination templates from Denmark and Sweden. The semantic relationships in SNOMED CT were used to quantify similarities and differences. Moreover, the analysis used these identified similarities to investigate the common content of a physical examination template. The analysis showed that there were both similarities and differences in physical examination templates, and the size of the templates varied from 18 to 49 fields. In the SNOMED CT analysis, exact matches and terminology similarities were represented in all template pairs. The number of exact matches ranged from 7 to 24. Moreover, the number of unrelated fields differed a lot from 1/18 to 22/35. Cross-country comparisons tended to have more unrelated content than within-country comparisons. On the basis of identified similarities, it was possible to define the common content of a physical examination. Nevertheless, a complete view on the physical examination required the inclusion of both exact matches and terminology similarities. This study revealed that a core set of items representing the physical examination templates can be generated when the analysis takes into account not only exact matches but also terminology

  7. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Science.gov (United States)

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  8. Surface and bulk 3D analysis of natural and processed ruby using electron probe micro analyzer and X-ray micro CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Sahoo, Rakesh K., E-mail: rakesh.materialscience@gmail.com; Singh, Saroj K.; Mishra, B.K.

    2016-08-15

    Highlights: • Firm linking between two advance techniques: Micro-CT and EPMA for mineral analysis. • Attempt to identify and differentiate the treated gem stone from natural counterpart. • 3D structural and surface elemental analysis of the natural gem stone. - Abstract: The change in surface compositional and bulk structural characteristics of the natural ruby stone, before and after heat treatment with lead oxide has been analyzed using two advance characterization techniques like: X-ray micro CT scan (μ-CT) and electron probe micro analyzer (EPMA). The analytical correlation between these two techniques in identification as well as in depth study of the ores and minerals before and after processing has been presented. Also, we describe the aesthetic enhancement of a low quality defective ruby stone by lead oxide filling and the sequential analysis of this ruby stone before and after treatment using these two advanced techniques to identify and to confirm the change in its aesthetic value. The cracks healing and pores filling by the metal oxide on the surface of the ruby have been analyzed using μ-CT and EPMA. Moreover, in this work we describe the advance characterization of the repaired gem stones especially ruby stones. This work will light up the path for in-depth understanding of diffusion mechanism and abstract information of impurity particles inside the minerals. Based on these observations, EPMA and micro CT are shown to be powerful tools for the identification as well as research in gem stones.

  9. Model of e-learning with electronic educational resources of new generation

    OpenAIRE

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  10. SPECT/CT workflow and imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beckers, Catherine [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Hustinx, Roland [University Hospital of Liege, Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, Liege (Belgium); Domaine Universitaire du Sart Tilman, Service de Medecine Nucleaire et Imagerie Oncologique, CHU de Liege, Liege (Belgium)

    2014-05-15

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  11. SPECT/CT workflow and imaging protocols

    International Nuclear Information System (INIS)

    Beckers, Catherine; Hustinx, Roland

    2014-01-01

    Introducing a hybrid imaging method such as single photon emission computed tomography (SPECT)/CT greatly alters the routine in the nuclear medicine department. It requires designing new workflow processes and the revision of original scheduling process and imaging protocols. In addition, the imaging protocol should be adapted for each individual patient, so that performing CT is fully justified and the CT procedure is fully tailored to address the clinical issue. Such refinements often occur before the procedure is started but may be required at some intermediate stage of the procedure. Furthermore, SPECT/CT leads in many instances to a new partnership with the radiology department. This article presents practical advice and highlights the key clinical elements which need to be considered to help understand the workflow process of SPECT/CT and optimise imaging protocols. The workflow process using SPECT/CT is complex in particular because of its bimodal character, the large spectrum of stakeholders, the multiplicity of their activities at various time points and the need for real-time decision-making. With help from analytical tools developed for quality assessment, the workflow process using SPECT/CT may be separated into related, but independent steps, each with its specific human and material resources to use as inputs or outputs. This helps identify factors that could contribute to failure in routine clinical practice. At each step of the process, practical aspects to optimise imaging procedure and protocols are developed. A decision-making algorithm for justifying each CT indication as well as the appropriateness of each CT protocol is the cornerstone of routine clinical practice using SPECT/CT. In conclusion, implementing hybrid SPECT/CT imaging requires new ways of working. It is highly rewarding from a clinical perspective, but it also proves to be a daily challenge in terms of management. (orig.)

  12. Impact factor of relationships between CT value and relative electron density for treatment planning system

    International Nuclear Information System (INIS)

    Feng Guosheng; Liang Yuan; Wu Danling; Hao Yanrong; Lu Heming; Chen Jiaxin; Liao Chaolong; Mo Ying; Huang Yihang

    2012-01-01

    Objective: To study the CT values of certain phantoms scanned by various CT scanners with dissimilar parameters. Methods: The CT values of tissue equivalent inserts was measured in the TM164 and CIRS-062 phantom scanned by TOSHIBA AQUILION TM , SIEMENS SOMATOM TM SENSATION TM 64 and SIEMENS SOMATOM TM SENSATION TM OPEN with different voltages,currents and slice thicknesses and then the corresponding CT-to-density curves was compared. Results: There are no significant differences of CT values with various currents and slice thicknesses and also for low atom number materials scanned by different scanners with various tube voltages. The CT values of high atom number materials have obvious differences scanned with tube voltage,the maximum is about 400 HU. There are also significant differences between CT-density curves of two phantoms in the range from soft tissues to dense bone, the maximum is up to 500 HU. Conclusions: CT-density curves were highly affected by materials of phantoms, scanners and tube voltages. It is necessary to measure the curve with a comfortable phantom and certain scanner to assure the accuracy for dose calculation for treatment planning system. (authors)

  13. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  14. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  15. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  16. Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART)

    International Nuclear Information System (INIS)

    Guan, Huaiqun; Zhu, Yunping

    1998-01-01

    Although electronic portal imaging devices (EPIDs) are efficient tools for radiation therapy verification, they only provide images of overlapped anatomic structures. We investigated using a fluorescent screen/CCD-based EPID, coupled with a novel multi-level scheme algebraic reconstruction technique (MLS-ART), for a feasibility study of portal computed tomography (CT) reconstructions. The CT images might be useful for radiation treatment planning and verification. We used an EPID, set it to work at the linear dynamic range and collimated 6 MV photons from a linear accelerator to a slit beam of 1 cm wide and 25 cm long. We performed scans under a total of ∼200 monitor units (MUs) for several phantoms in which we varied the number of projections and MUs per projection. The reconstructed images demonstrated that using the new MLS-ART technique megavoltage portal CT with a total of 200 MUs can achieve a contrast detectibility of ∼2.5% (object size 5mmx5mm) and a spatial resolution of 2.5 mm. (author)

  17. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  18. Dynamic Resource Allocation with the arcControlTower

    CERN Document Server

    Filipcic, Andrej; The ATLAS collaboration; Nilsen, Jon Kerr

    2015-01-01

    Distributed computing resources available for high-energy physics research are becoming less dedicated to one type of workflow and researchers’ workloads are increasingly exploiting modern computing technologies such as parallelism. The current pilot job management model used by many experiments relies on static dedicated resources and cannot easily adapt to these changes. The model used for ATLAS in Nordic countries and some other places enables a flexible job management system based on dynamic resources allocation. Rather than a fixed set of resources managed centrally, the model allows resources to be requested on the fly. The ARC Computing Element (ARC-CE) and ARC Control Tower (aCT) are the key components of the model. The aCT requests jobs from the ATLAS job management system (PanDA) and submits a fully-formed job description to ARC-CEs. ARC-CE can then dynamically request the required resources from the underlying batch system. In this paper we describe the architecture of the model and the experienc...

  19. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  20. Ab Initio Analysis of Auger-Assisted Electron Transfer.

    Science.gov (United States)

    Hyeon-Deuk, Kim; Kim, Joonghan; Prezhdo, Oleg V

    2015-01-15

    Quantum confinement in nanoscale materials allows Auger-type electron-hole energy exchange. We show by direct time-domain atomistic simulation and analytic theory that Auger processes give rise to a new mechanism of charge transfer (CT) on the nanoscale. Auger-assisted CT eliminates the renown Marcus inverted regime, rationalizing recent experiments on CT from quantum dots to molecular adsorbates. The ab initio simulation reveals a complex interplay of the electron-hole and charge-phonon channels of energy exchange, demonstrating a variety of CT scenarios. The developed Marcus rate theory for Auger-assisted CT describes, without adjustable parameters, the experimental plateau of the CT rate in the region of large donor-acceptor energy gap. The analytic theory and atomistic insights apply broadly to charge and energy transfer in nanoscale systems.

  1. Microscale reconstruction of biogeochemical substrates using multimode X-ray tomography and scanning electron microscopy

    Science.gov (United States)

    Miller, M.; Miller, E.; Liu, J.; Lund, R. M.; McKinley, J. P.

    2012-12-01

    X-ray computed tomography (CT), scanning electron microscopy (SEM), electron microprobe analysis (EMP), and computational image analysis are mature technologies used in many disciplines. Cross-discipline combination of these imaging and image-analysis technologies is the focus of this research, which uses laboratory and light-source resources in an iterative approach. The objective is to produce images across length scales, taking advantage of instrumentation that is optimized for each scale, and to unify them into a single compositional reconstruction. Initially, CT images will be collected using both x-ray absorption and differential phase contrast modes. The imaged sample will then be physically sectioned and the exposed surfaces imaged and characterized via SEM/EMP. The voxel slice corresponding to the physical sample surface will be isolated computationally, and the volumetric data will be combined with two-dimensional SEM images along CT image planes. This registration step will take advantage of the similarity between the X-ray absorption (CT) and backscattered electron (SEM) coefficients (both proportional to average atomic number in the interrogated volume) as well as the images' mutual information. Elemental and solid-phase distributions on the exposed surfaces, co-registered with SEM images, will be mapped using EMP. The solid-phase distribution will be propagated into three-dimensional space using computational methods relying on the estimation of compositional distributions derived from the CT data. If necessary, solid-phase and pore-space boundaries will be resolved using X-ray differential phase contrast tomography, x-ray fluorescence tomography, and absorption-edge microtomography at a light-source facility. Computational methods will be developed to register and model images collected over varying scales and data types. Image resolution, physically and dynamically, is qualitatively different for the electron microscopy and CT methodologies. Routine

  2. Study of effect of different CT scanning protocols on HU variation and their impact on TPS calculations

    International Nuclear Information System (INIS)

    Mahur, Mamta; Sharma, Richa; Sasindaran, M.; Singh, Anshu; Gedam, Varsha; Negi, P.S.; Grover, R.K.

    2016-01-01

    Computer tomographic (CT) scans are used to correct for tissue inhomogeneties in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and relative electron densities, which is the basic input for radiotherapy planning systems which consider tissue heterogeneities. The purpose of this study is to investigate the influence of different CT scan parameters (kVp, mAs) on uniformity of CT numbers versus relative electron density (HURED) curves and their different dosimetric impact

  3. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  4. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  5. Electron beam CT diagnosis of congenital unilateral absence of pulmonary artery

    International Nuclear Information System (INIS)

    Zhou Yuan; Dai Ruping; Cao Cheng; Zhang Gejun; Jing Baolian

    2003-01-01

    Objective: To evaluate the clinical value of electron beam CT (EBCT) in diagnosing congenital unilateral absence of pulmonary artery (UAPA). Methods: Patients with clinically suspected pulmonary artery disease or primary pulmonary hypertension underwent EBCT scanning. EBCT confirmed the diagnosis of UAPA in 11 patients, who were also evaluated with echocardiography and chest roentgenography. Cardioangiography and nuclear ventilation-perfusion scan were performed in some patients for a comparative study. Results: 4 female adults had UAPA with out associated congenital anomaly. 3 male children with coexisting complex congenital abnormality had unilateral absence of the left pulmonary artery and 4 patients coexisted other simple cardiovascular anomaly. EBCT scanning simultaneously displayed topographic pattern of both unilateral absence of pulmonary artery and coexisting congenital cardiovascular anomaly, as well as lung diseases. Conclusion: UAPA diagnosed in childhood usually has unilateral absence of the left pulmonary artery and associated congenital cardiovascular anomaly, while UAPA diagnosed in adult usually has UAPA on the right side without associated congenital anomaly. EBCT is one of the optimal imaging techniques in diagnosing UAPA and it greatly increases the diagnostic efficacy than echocardiography dose. Both EBCT and cardioangiography have their own advantages, however, EBCT, as a noninvasive method, should be complementary and not exclusive

  6. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Directory of Open Access Journals (Sweden)

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  7. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  8. Derivation of linear attenuation coefficients from CT numbers for low-energy photons

    International Nuclear Information System (INIS)

    Watanabe, Y.

    1999-01-01

    One can estimate photon attenuation properties from the CT number. In a standard method one assumes that the linear attenuation coefficient is proportional to electron density and ignores its nonlinear dependence on atomic number. When the photon energy is lower than about 50 keV, such as for brachytherapy applications, however, photoelectric absorption and Rayleigh scattering become important. Hence the atomic number must be explicitly considered in estimating the linear attenuation coefficient. In this study we propose a method to more accurately estimate the linear attenuation coefficient of low-energy photons from CT numbers. We formulate an equation that relates the CT number to the electron density and the effective atomic number. We use a CT calibration phantom to determine unknown coefficients in the equation. The equation with a given CT number is then solved for the effective atomic number, which in turn is used to calculate the linear attenuation coefficient for low-energy photons. We use the CT phantom to test the new method. The method significantly improves the standard method in estimating the attenuation coefficient at low photon energies (20keV≤E≤40keV) for materials with high atomic numbers. (author)

  9. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Science.gov (United States)

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  10. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms

    Science.gov (United States)

    Rui, Xue; Cheng, Lishui; Long, Yong; Fu, Lin; Alessio, Adam M.; Asma, Evren; Kinahan, Paul E.; De Man, Bruno

    2015-01-01

    simulated, sparse view protocols with 41 and 24 views best balanced the tradeoff between electronic noise and aliasing artifacts. In terms of lesion activity error and ensemble RMSE of the PET images, these two protocols, when combined with MBIR, are able to provide results that are comparable to the baseline full dose CT scan. View interpolation significantly improves the performance of FDK reconstruction but was not necessary for MBIR. With the more technically feasible continuous exposure data acquisition, the CT images show an increase in azimuthal blur compared to tube pulsing. However, this blurring generally does not have a measureable impact on PET reconstructed images. Conclusions Our simulations demonstrated that ultra-low-dose CT-based attenuation correction can be achieved at dose levels on the order of 0.044 mAs with little impact on PET image quality. Highly sparse 41- or 24- view ultra-low dose CT scans are feasible for PET attenuation correction, providing the best tradeoff between electronic noise and view aliasing artifacts. The continuous exposure acquisition mode could potentially be implemented in current commercially available scanners, thus enabling sparse view data acquisition without requiring x-ray tubes capable of operating in a pulsing mode. PMID:26352168

  12. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  13. The effectiveness of WebCT as a progress-assessment tool in ...

    African Journals Online (AJOL)

    Journal for Language Teaching ... In support of this strategy the US has implemented WebCT as an electronic course management system. ... The WebCT assessment function was used as a complement to traditional lectures and traditional end-of-course written assessment to enrich teaching, promote learning and gauge ...

  14. CHEP2015: Dynamic Resource Allocation with arcControlTower

    CERN Document Server

    Filipcic, Andrej; The ATLAS collaboration; Nilsen, Jon Kerr

    2015-01-01

    Distributed computing resources available for high-energy physics research are becoming less dedicated to one type of workflow and researchers’ workloads are increasingly exploiting modern computing technologies such as parallelism. The current pilot job management model used by many experiments relies on static dedicated resources and cannot easily adapt to these changes. The model used for ATLAS in Nordic countries and some other places enables a flexible job management system based on dynamic resources allocation. Rather than a fixed set of resources managed centrally, the model allows resources to be requested on the fly. The ARC Computing Element (ARC-CE) and ARC Control Tower (aCT) are the key components of the model. The aCT requests jobs from the ATLAS job mangement system (Panda) and submits a fully-formed job description to ARC-CEs. ARC-CE can then dynamically request the required resources from the underlying batch system. In this paper we describe the architecture of the model and the experience...

  15. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  16. Sources and resources for oncologists to help answer the question: is PET/CT appropriate for my patient?

    Science.gov (United States)

    Karantanis, Dimitrios; Allen-Auerbach, Martin; Czernin, Johannes

    2012-01-01

    Positron emission tomography (PET)/computed tomography (CT)-subsequently referred to as PET/CT is emerging as a critically important diagnostic tool in oncology. There has been a substantial increase in the utilization of this modality over the last decade. The optimal imaging protocols are, however, still not established which results in considerable confusion and uncertainty among referring physicians and providers. Oncologists, hematologists and other physicians managing oncologic patients frequently face the dilemma of whether or not to order a PET/CT scan for their patients. The large body of evidence from clinical research often overwhelms the ability of physicians to stay adequately informed on the disease specific performance of PET/CT. Moreover, regulatory agencies have changed their requirements for reimbursement of PET/CT scans in an effort to curtail health care expenditures. In this article we attempt to inform users and providers about the appropriate use of this technology.

  17. Neutron-induced electronic failures around a high-energy linear accelerator

    International Nuclear Information System (INIS)

    Kry, Stephen F.; Johnson, Jennifer L.; White, R. Allen; Howell, Rebecca M.; Kudchadker, Rajat J.; Gillin, Michael T.

    2011-01-01

    Purpose: After a new in-vault CT-on-rails system repeatedly malfunctioned following use of a high-energy radiotherapy beam, we investigated the presence and impact of neutron radiation on this electronic system, as well as neutron shielding options. Methods: We first determined the CT scanner's failure rate as a function of the number of 18 MV monitor units (MUs) delivered. We then re-examined the failure rate with both 2.7-cm-thick and 7.6-cm-thick borated polyethylene (BPE) covering the linac head for neutron shielding. To further examine shielding options, as well as to explore which neutrons were relevant to the scanner failure, Monte Carlo simulations were used to calculate the neutron fluence and spectrum in the bore of the CT scanner. Simulations included BPE covering the CT scanner itself as well as covering the linac head. Results: We found that the CT scanner had a 57% chance of failure after the delivery of 200 MUs. While the addition of neutron shielding to the accelerator head reduced this risk of failure, the benefit was minimal and even 7.6 cm of BPE was still associated with a 29% chance of failure after the delivery of 200 MU. This shielding benefit was achieved regardless of whether the linac head or CT scanner was shielded. Additionally, it was determined that fast neutrons were primarily responsible for the electronic failures. Conclusions: As illustrated by the CT-on-rails system in the current study, physicists should be aware that electronic systems may be highly sensitive to neutron radiation. Medical physicists should therefore monitor electronic systems that have not been evaluated for potential neutron sensitivity. This is particularly relevant as electronics are increasingly common in the therapy vault and newer electronic systems may exhibit increased sensitivity.

  18. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  19. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  20. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  1. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Directory of Open Access Journals (Sweden)

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  2. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    International Nuclear Information System (INIS)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  3. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Directory of Open Access Journals (Sweden)

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  4. CT planning of boost irradiation in radiotherapy of breast cancer after conservative surgery

    International Nuclear Information System (INIS)

    Messer, Peter M.; Kirikuta, Ion C.; Bratengeier, Klaus; Flentje, Michael

    1997-01-01

    Background and purpose: A study was performed to compare the accuracy of clinical treatment set-up and CT planning of boost irradiation in radiotherapy of breast cancer. Material and methods: Between September 1993 and October 1994, 45 women who underwent breast conserving surgery and irradiation containing a boost to the tumour bed were investigated. Prospective evaluation of CT planning of the boost was carried out. The target volume/boost field, electron energy and treatment set-up had been defined on the basis of clinical examination, initial and postsurgical mammograms by one radiotherapist. Next, a planning CT was performed in treatment position and a CT-based treatment plan was calculated according to a target volume defined by another radiotherapist. The clinical treatment set-up was imported into our computer planning system and the resulting isodose plots were compared with those from CT planning and reviewed critically. Results: The clinically defined treatment set-up had to be modified in 80% of the patients. Most discrepancies observed were related to the size of the boost field itself and the chosen electron energy. Minor changes had to be made with respect to angle of table and gantry. Conclusions: Critical review of the isodose plots from both methods showed clear advantages for CT planning. Guidelines for target definition in CT planning of boost irradiation and subgroups of patients benefiting from this technique are described

  5. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  6. Big Hat, No Cattle: Managing Human Resources, Part 2.

    Science.gov (United States)

    Skinner, Wickham

    1982-01-01

    The author discusses why business has difficulty in motivating its employees and proposes a new approach to developing human resources. Discusses mistaken premises, personnel and supervision, setting a long-term goal, changing management's philosophy, and selling human resource development as a company priority. (CT)

  7. Clinical Application of colored three-dimensional CT (3D-CT) for brain tumors using helical scanning CT (HES-CT)

    International Nuclear Information System (INIS)

    Ogura, Yuko; Katada, Kazuhiro; Fujisawa, Kazuhisa; Imai, Fumihiro; Kawase, Tsukasa; Kamei, Yoshifumi; Kanno, Tetsuo; Takeshita, Gen; Koga, Sukehiko

    1995-01-01

    We applied colored three-dimensional CT (colored 3D-CT) images to distinguish brain tumors from the surrounding vascular and bony structures using a work station system and helical scanning CT (HES-CT). CT scanners with a slip-ring system were employed (TCT-900S and X vigor). A slice thickness of 2 mm and bed speed of 2 mm/s were used. The volume of contrast medium injected was 60 to 70 ml. Four to 8 colors were used for the tissue segmentation on the workstation system (xtension) using the data transferred from HES-CT. Tissue segmentation succeeded on the colored 3D-CT images in all 13 cases. The relationship between the tumors and the surrounding structures were easily recognized. The technique was useful to simulate operative fields, because deep structures could be visualized by cutting and drilling the colored 3D-CT volumetric data. On the basis of our findings, we suggest that colored 3D-CT images should be used as a supplementary aid for preoperative simulation. (author)

  8. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  9. Electron-beam CT diagnosis of the viscero-atrial heterotaxy syndrome

    International Nuclear Information System (INIS)

    Yang Youyou; Dai Ruping; Jing Baolian; He Sha; Bai Hua; Li Xiangmin; Zhou Xuhui; Peng Qian; Meng Quanfei

    2002-01-01

    Objective: To assess the usefulness of electron-beam CT (EBCT) in diagnosis of the viscero-atrial heterotaxy syndrome. Methods: Ten patients with the viscero-atrial heterotaxy syndrome were evaluated. The patients ranged in age from 7 months to 17 years (averaged 9.5 years). Five of the patients underwent EBCT contrast single slice mode while another 5 patients did continuous volume scan obtained from the superior aperture of thorax to the middle part of abdomen. All the patients had both angiocardiogram and echocardiogram, and 6 patients had operative outcomes. Results; (1) Eight patients with right atrial isomerism, bilaterally morphologic right atrial appendages, right lobe dominant symmetric liver, bilaterally epi-arterial bronchi, trilobed lungs, and total anomalous pulmonary venous connectional were clearly detected. Endocardial cushions defect, pulmonary stenosis, right-sided aortic arch and descending aorta were documented in 7 patients. Double outlet of right ventricle was imaged in 6 patients and hiatal hernia in 2 patients. Neither a spleen nor splenulus were found. (2) Two patients with left atrial isomerism, bilaterally morphologic left atrial appendages, left lobe dominant symmetric liver, bilaterally hyparterial bronchi, bilobed lungs, double outlet of right ventricle, pulmonary stenosis, interruption of inferior vena cave, right-sided aortic arch, and descending aorta were documented. Endocardial cushions defect was detected in 1 patient. Multiple spleens were demonstrated in the right upper abdomen in the 2 patients. (3) The number of abnormal observations detected by EBCT was 116, while that done by angiocardiogram and echocardiogram were 65 and 43 respectively. Conclusion: EBCT is a useful tool in the evaluation of patients with the syndrome of viscero-atrial heterotaxia

  10. Ultra-low dose CT attenuation correction for PET/CT

    International Nuclear Information System (INIS)

    Xia Ting; Kinahan, Paul E; Alessio, Adam M; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren

    2012-01-01

    A challenge for positron emission tomography/computed tomography (PET/CT) quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently available, lowest dose CT techniques, extended duration cine CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. (paper)

  11. Ultra-low dose CT attenuation correction for PET/CT

    Science.gov (United States)

    Xia, Ting; Alessio, Adam M.; De Man, Bruno; Manjeshwar, Ravindra; Asma, Evren; Kinahan, Paul E.

    2012-01-01

    A challenge for PET/CT quantitation is patient respiratory motion, which can cause an underestimation of lesion activity uptake and an overestimation of lesion volume. Several respiratory motion correction methods benefit from longer duration CT scans that are phase matched with PET scans. However, even with the currently-available, lowest dose CT techniques, extended duration CINE CT scans impart a substantially high radiation dose. This study evaluates methods designed to reduce CT radiation dose in PET/CT scanning. Methods We investigated selected combinations of dose reduced acquisition and noise suppression methods that take advantage of the reduced requirement of CT for PET attenuation correction (AC). These include reducing CT tube current, optimizing CT tube voltage, adding filtration, CT sinogram smoothing and clipping. We explored the impact of these methods on PET quantitation via simulations on different digital phantoms. Results CT tube current can be reduced much lower for AC than that in low dose CT protocols. Spectra that are higher energy and narrower are generally more dose efficient with respect to PET image quality. Sinogram smoothing could be used to compensate for the increased noise and artifacts at radiation dose reduced CT images, which allows for a further reduction of CT dose with no penalty for PET image quantitation. Conclusion When CT is not used for diagnostic and anatomical localization purposes, we showed that ultra-low dose CT for PET/CT is feasible. The significant dose reduction strategies proposed here could enable respiratory motion compensation methods that require extended duration CT scans and reduce radiation exposure in general for all PET/CT imaging. PMID:22156174

  12. Energy Dependence of Measured CT Numbers on Substituted Materials Used for CT Number Calibration of Radiotherapy Treatment Planning Systems.

    Directory of Open Access Journals (Sweden)

    Reza Mahmoudi

    Full Text Available For accurate dose calculations, it is necessary to provide a correct relationship between the CT numbers and electron density in radiotherapy treatment planning systems (TPSs. The purpose of this study was to investigate the energy dependence of measured CT numbers on substituted materials used for CT number calibration of radiotherapy TPSs and the resulting errors in the treatment planning calculation doses.In this study, we designed a cylindrical water phantom with different materials used as tissue equivalent materials for the simulation of tissues and obtaining the related CT numbers. For evaluating the effect of CT number variations of substituted materials due to energy changing of scanner (kVp on the dose calculation of TPS, the slices of the scanned phantom at three kVp's were imported into the desired TPSs (MIRS and CorePLAN. Dose calculations were performed on two TPSs.The mean absolute percentage differences between the CT numbers of CT scanner and two treatment planning systems for all the samples were 3.22%±2.57% for CorePLAN and 2.88%±2.11% for MIRS. It was also found that the maximum absolute percentage difference between all of the calculated doses from each photon beam of linac (6 and 15 MV at three kVp's was less than 1.2%.The present study revealed that, for the materials with effective low atomic number, the mean CT number increased with increasing energy, which was opposite for the materials with an effective high atomic number. We concluded that the tissue substitute materials had a different behavior in the energy ranges from 80 to 130 kVp. So, it is necessary to consider the energy dependence of the substitute materials used for the measurement or calibration of CT number for radiotherapy treatment planning systems.

  13. Clinical application of gated CT and dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T; Oyama, Y; Ashida, H; Uji, T [Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine

    1980-03-01

    Gated CT and dynamic CT were outlined. Experiences of portal hypertension accompanied by venous mass in posterior mediastinum and the usefulness of dynamic CT for this disease were described. Gated CT of the heart could visualize intracardiac structures and morphological abnormalities by improving technique of post-data-aquisition correlation. Changes with time in CT images of normal kidneys were discussed on patients whose unilateral or bilateral kidneys were thought to be normal and who had received dynamic scan. Dynamic scan could visualize well blood circulation and mechanism of urine excretion in the kidney, which suggests a possibility of CT to detect not only morphological abnormalities but also functional disturbance of the kidney. The effectiveness of conventional CT study might be promoted in dynamic CT of the head.

  14. Correction for ‘artificial’ electron disequilibrium due to cone-beam CT density errors: implications for on-line adaptive stereotactic body radiation therapy of lung

    International Nuclear Information System (INIS)

    Disher, Brandon; Hajdok, George; Craig, Jeff; Gaede, Stewart; Battista, Jerry J; Wang, An

    2013-01-01

    Cone-beam computed tomography (CBCT) has rapidly become a clinically useful imaging modality for image-guided radiation therapy. Unfortunately, CBCT images of the thorax are susceptible to artefacts due to scattered photons, beam hardening, lag in data acquisition, and respiratory motion during a slow scan. These limitations cause dose errors when CBCT image data are used directly in dose computations for on-line, dose adaptive radiation therapy (DART). The purpose of this work is to assess the magnitude of errors in CBCT numbers (HU), and determine the resultant effects on derived tissue density and computed dose accuracy for stereotactic body radiation therapy (SBRT) of lung cancer. Planning CT (PCT) images of three lung patients were acquired using a Philips multi-slice helical CT simulator, while CBCT images were obtained with a Varian On-Board Imaging system. To account for erroneous CBCT data, three practical correction techniques were tested: (1) conversion of CBCT numbers to electron density using phantoms, (2) replacement of individual CBCT pixel values with bulk CT numbers, averaged from PCT images for tissue regions, and (3) limited replacement of CBCT lung pixels values (LCT) likely to produce artificial lateral electron disequilibrium. For each corrected CBCT data set, lung SBRT dose distributions were computed for a 6 MV volume modulated arc therapy (VMAT) technique within the Philips Pinnacle treatment planning system. The reference prescription dose was set such that 95% of the planning target volume (PTV) received at least 54 Gy (i.e. D95). Further, we used the relative depth dose factor as an a priori index to predict the effects of incorrect low tissue density on computed lung dose in regions of severe electron disequilibrium. CT number profiles from co-registered CBCT and PCT patient lung images revealed many reduced lung pixel values in CBCT data, with some pixels corresponding to vacuum (−1000 HU). Similarly, CBCT data in a plastic lung

  15. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  16. Comparative study of the electron density profiles in the compact torus plasma merging experiments

    International Nuclear Information System (INIS)

    Hayashiya, Hitoshi; Asaka, Takeo; Katsurai, Makoto

    2003-01-01

    Following two previous papers on the comparative studies of the electron density distributions for a single compact torus (CT) and a spherical tokamak (ST), and for the a single ST and a merged ST, a comparative study on the dynamics of the electron density profile and after the CT and ST plasma merging process was performed. The sharpness of the peak in the electron density profile around the mid-plane just after the merging of CT with a low safety factor (q value) such as RFP or spheromak is found to be related to the speed of the magnetic axis during the plasma merging process. It is also found that the electron density gradient near the plasma edge in a high q ST is larger than that of a low q CT. High q ST is found to be provided with the magnetic structure which is able to sustain a large thermal pressure by a strong j x B force. Despite these differences in the electron density profile between CT and ST during merging, the confinement characteristics evaluated from the number of electrons confined within the magnetic separatrix after the completion of the merging is almost similar between in the merging CT and in the merging ST. For all configurations, the electron density profiles after the completion of the merging are analogous to those of the corresponding single configuration produced without the merging process. (author)

  17. Improvement of analysis precision upon the atomic number and electron density measurement by the dual x-ray CT

    Science.gov (United States)

    Imura, Yukino; Morii, Hisashi; Koike, Akifumi; Okunoyama, Takaharu; Neo, Yoichiro; Mimura, Hidenori; Aoki, Toru

    2010-08-01

    To identify the factor impairing the material identification parameters, which is provided by the dual-energy X-ray computed tomography method using a conventional X-ray tube and a CdTe detector, linear attenuation coefficient was measured by the radioactivity of radio isotopes and compared with theoretical figure. In our study, the atomic number and the electron density is calculated from the linear attenuation coefficient obtained in CT measurement by 64-channel CdTe line detector. To estimate accuracy of CdTe line sensor, it is needed to obtain the linear attenuation coefficient accurately. Using a single detector, the linear attenuation coefficient is verified for accuracy. The energy resolution of CdTe detectors and the method of reconstruction are discussed.

  18. MELAS syndrome in a child: CT and MR findings

    International Nuclear Information System (INIS)

    Choi, Bye Young; Hong, Soo Jong; Cho, Jeong Hee; Suh, Dae Chul; Hong, Chang Yee

    1993-01-01

    MELAS (mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes) is one of the mitochondrial encephalomyopathy, A rare disease caused by a disturbance of the mitochondrial chain of respiration. MELAS is confirmed by typical light and electron microscopic findings: 'ragged red fibers' by modified Gomori trichrome stain on light microscope and numerous abnormal mitochondria on electron microscope. We experienced a boy with the characteristic clinical and pathologic findings of MELAS. Our patient demonstrated bilateral basal ganglia calcifications and infarction at right parieto-occipital and thalamic areas on CT and MR. We found that MRI was more sensitive and represented the infarcted lesions better than CT. Detection of cerebral insults of MELAS by MRI is important in making decision on patient treatment and also in prediction of the patient prognosis

  19. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  20. Library resources on the Internet

    Science.gov (United States)

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  1. Level-set segmentation of pulmonary nodules in megavolt electronic portal images using a CT prior

    International Nuclear Information System (INIS)

    Schildkraut, J. S.; Prosser, N.; Savakis, A.; Gomez, J.; Nazareth, D.; Singh, A. K.; Malhotra, H. K.

    2010-01-01

    Purpose: Pulmonary nodules present unique problems during radiation treatment due to nodule position uncertainty that is caused by respiration. The radiation field has to be enlarged to account for nodule motion during treatment. The purpose of this work is to provide a method of locating a pulmonary nodule in a megavolt portal image that can be used to reduce the internal target volume (ITV) during radiation therapy. A reduction in the ITV would result in a decrease in radiation toxicity to healthy tissue. Methods: Eight patients with nonsmall cell lung cancer were used in this study. CT scans that include the pulmonary nodule were captured with a GE Healthcare LightSpeed RT 16 scanner. Megavolt portal images were acquired with a Varian Trilogy unit equipped with an AS1000 electronic portal imaging device. The nodule localization method uses grayscale morphological filtering and level-set segmentation with a prior. The treatment-time portion of the algorithm is implemented on a graphical processing unit. Results: The method was retrospectively tested on eight cases that include a total of 151 megavolt portal image frames. The method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases. The treatment phase portion of the method has a subsecond execution time that makes it suitable for near-real-time nodule localization. Conclusions: A method was developed to localize a pulmonary nodule in a megavolt portal image. The method uses the characteristics of the nodule in a prior CT scan to enhance the nodule in the portal image and to identify the nodule region by level-set segmentation. In a retrospective study, the method reduced the nodule position uncertainty by an average of 40% for seven out of the eight cases studied.

  2. Obtaining the conversion curve of CT numbers to electron density from the effective energy of the CT using the dummy SEFM; Obtencion de la curva de conversion de numeros TC a densidad electronica a partir de la energia efectiva del TC usando el maniqui de la SEFM

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Viera Cueto, J. A.; Garcia Pareja, S.; Benitez Villegas, E. M.; Moreno Saiz, E. M.; Bodineau Gil, C.; Caudepon Moreno, F.

    2011-07-01

    The objective of this work is to obtain the conversion curve of Hounsfield units (A) versus electron densities using a mannequin with different tissue equivalent materials. This provides for the effective energy beam CT and is used to characterize the linear coefficients of absorption of different materials that comprise the dummy.

  3. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  4. Selection and Evaluation of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  5. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  6. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  7. An Investigation of Methods for CT Synthesis in MR-only Radiotherapy

    DEFF Research Database (Denmark)

    Andreasen, Daniel

    In recent years, the interest in using magnetic resonance (MR) imaging in radiotherapy (RT) has increased. This is because MR has a superior soft tissue contrast compared to computed tomography (CT), which makes it a better modality for delineating the target volume (tumor) and possible organs...... at risk (OARs). In an MR/CT work-flow, independent MR and CT scans are acquired. The target and possible OARs are delineated on the MR and then transferred to CT by aligning the data using a registration. This introduces the risk of systematic registration errors especially in non-rigid body structures......, the consequence being a systematic miss of target or increased dose to healthy tissue. Radiotherapy based on MR as the only modality removes this uncertainty and simplifies the clinical work-flow. However, the information on electron density which is usually contained in the CT must now be derived from the MR...

  8. Patient position matching between SPECT and CT

    International Nuclear Information System (INIS)

    Eubig, C.; Lodhi, L.M.; Trueblood, J.H.; Kingsbury, T.; Burke, G.; Flickenger, F.

    1990-01-01

    Since the authors had previously developed an ability for accurate repositioning of patients by means of video imaging of their external features, it was their purpose to determine if separate video systems placed in SPECT and CT rooms could be positioned and a calibration procedure for each modality developed to assure easy identification and acquisition of corresponding congruent axial image sections through the patient. A video frame grabber is used to acquire an image of the patient in one room and superimpose it on a similar image of the patient in the other room. A radioactive ruler visible at CT images obtained with a gamma camera computer, and a CT scout image are used to adjust the initial relative position of the video cameras and calibrate the acquisition parameters of both systems. The success of this alignment procedure was tested with a body phantom. The body phantom studies indicate that this method of positioning the patient and acquiring corresponding aligned CT and SPECT axial sections can be successful where internal organ shift between the acquisitions is minimal. This should lead to a reduction of the time and computer resources necessary to fuse or superimpose images of corresponding patient sections acquired with different modalities

  9. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Directory of Open Access Journals (Sweden)

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  10. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Science.gov (United States)

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  11. Verification of CTDI and Dlp values for a head tomography reported by the manufacturers of the CT scanners, using a CT dose profiler probe, a head phantom and a piranha electrometer

    International Nuclear Information System (INIS)

    Castillo C, E.; Garcia F, I. B.; Garcia H, J.; Roman L, S.; Salmeron C, O.

    2015-10-01

    The extensive use of Computed Tomography (CT) and the associated increase in patient dose calls for an accurate dose evaluation technique. The CT contributes up to 70% of the total dose given to patients during X-ray examinations. The rapid advancements in CT technology are placing new demands on the methods and equipment that are used for quality assurance. The wide beam widths found in CT scanners with multiple beam apertures make it impossible to use existing CT ionization chambers to measure the total dose given to the patient. Using a standard 10 cm CT ionization chamber may result in inaccurate measurements due to underestimation of the dose profile for wide beams. The use a CT dose profiler based on solid-state technology and the Piranha electrometer from RTI electronics provides a potential solution to the arising concerns over patient dose. This study intend to evaluate the feasibility and accuracy of CT Dose Index (CTDI) and Dose Length Product (Dlp) values for a head tomography reported by the manufacturers of the CT scanners at each study. (Author)

  12. Verification of CTDI and Dlp values for a head tomography reported by the manufacturers of the CT scanners, using a CT dose profiler probe, a head phantom and a piranha electrometer

    Energy Technology Data Exchange (ETDEWEB)

    Castillo C, E.; Garcia F, I. B.; Garcia H, J.; Roman L, S. [Servicios de Salud de Michoacan, Centro Estatal de Atencion Oncologica, Gertrudis Bocanegra No. 300, Col. Cuauhtemoc, 58020 Morelia, Michoacan (Mexico); Salmeron C, O., E-mail: edithcastillocorona@gmail.com [Servicios de Salud de Michoacan, Hospital General Dr. Miguel Silva, Isidro Huarte s/n, Centro Historico, 58000 Morelia, Michoacan (Mexico)

    2015-10-15

    The extensive use of Computed Tomography (CT) and the associated increase in patient dose calls for an accurate dose evaluation technique. The CT contributes up to 70% of the total dose given to patients during X-ray examinations. The rapid advancements in CT technology are placing new demands on the methods and equipment that are used for quality assurance. The wide beam widths found in CT scanners with multiple beam apertures make it impossible to use existing CT ionization chambers to measure the total dose given to the patient. Using a standard 10 cm CT ionization chamber may result in inaccurate measurements due to underestimation of the dose profile for wide beams. The use a CT dose profiler based on solid-state technology and the Piranha electrometer from RTI electronics provides a potential solution to the arising concerns over patient dose. This study intend to evaluate the feasibility and accuracy of CT Dose Index (CTDI) and Dose Length Product (Dlp) values for a head tomography reported by the manufacturers of the CT scanners at each study. (Author)

  13. The appearance and effects of metallic implants in CT images

    International Nuclear Information System (INIS)

    Kairn, T.; Crowe, S.B.; Trapp, J.V.; Fogg, P.

    2013-01-01

    The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging artefacts that may occur within the implants themselves. This study examines CT images of a set of simple metallic objects, immersed in water, in order to evaluate reliability and variability of CT numbers (Hounsfield units, HUs) within medical implants. Model implants with a range of sizes (heights from 2.2 to 49.6 mm), electron densities (from 2.3 to 7.7 times the electron density of water) and effective atomic numbers (from 3.9 to 9.0 times the effective atomic number of water in a CT X-ray beam) were created by stacking metal coins from several currencies. These 'implants' were CT scanned within a large (31.0 cm across) and a small (12.8 cm across) water phantom. Resulting HU values are as much as 50 % lower than the result of extrapolating standard electron density calibration data (obtained for tissue and bone densities) up to the metal densities and there is a 6 % difference between the results obtained by scanning with 120 and 140 kVp tube potentials. Profiles through the implants show localised cupping artefacts, within the implants, as well as a gradual decline in HU outside the implants that can cause the implants' sizes to be over estimated by 1.3–9.0 mm. These effects are exacerbated when the implants are scanned in the small phantom or at the side of the large phantom, due to reduced pre-hardening of the X-ray beam in these configurations. These results demonstrate the necessity of over-riding the densities of metallic implants, as well as their artefacts in tissue, in order to obtain accurate radiotherapy dose calculations.

  14. The appearance and effects of metallic implants in CT images.

    Science.gov (United States)

    Kairn, T; Crowe, S B; Fogg, P; Trapp, J V

    2013-06-01

    The computed tomography (CT) imaging artefacts that metallic medical implants produce in surrounding tissues are usually contoured and over-ridden during radiotherapy treatment planning. In cases where radiotherapy treatment beams unavoidably pass though implants, it is especially important to understand the imaging artefacts that may occur within the implants themselves. This study examines CT images of a set of simple metallic objects, immersed in water, in order to evaluate reliability and variability of CT numbers (Hounsfield units, HUs) within medical implants. Model implants with a range of sizes (heights from 2.2 to 49.6 mm), electron densities (from 2.3 to 7.7 times the electron density of water) and effective atomic numbers (from 3.9 to 9.0 times the effective atomic number of water in a CT X-ray beam) were created by stacking metal coins from several currencies. These 'implants' were CT scanned within a large (31.0 cm across) and a small (12.8 cm across) water phantom. Resulting HU values are as much as 50 % lower than the result of extrapolating standard electron density calibration data (obtained for tissue and bone densities) up to the metal densities and there is a 6 % difference between the results obtained by scanning with 120 and 140 kVp tube potentials. Profiles through the implants show localised cupping artefacts, within the implants, as well as a gradual decline in HU outside the implants that can cause the implants' sizes to be over estimated by 1.3-9.0 mm. These effects are exacerbated when the implants are scanned in the small phantom or at the side of the large phantom, due to reduced pre-hardening of the X-ray beam in these configurations. These results demonstrate the necessity of over-riding the densities of metallic implants, as well as their artefacts in tissue, in order to obtain accurate radiotherapy dose calculations.

  15. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  16. Investigation of ultra low-dose scans in the context of quantum-counting clinical CT

    Science.gov (United States)

    Weidinger, T.; Buzug, T. M.; Flohr, T.; Fung, G. S. K.; Kappler, S.; Stierstorfer, K.; Tsui, B. M. W.

    2012-03-01

    In clinical computed tomography (CT), images from patient examinations taken with conventional scanners exhibit noise characteristics governed by electronics noise, when scanning strongly attenuating obese patients or with an ultra-low X-ray dose. Unlike CT systems based on energy integrating detectors, a system with a quantum counting detector does not suffer from this drawback. Instead, the noise from the electronics mainly affects the spectral resolution of these detectors. Therefore, it does not contribute to the image noise in spectrally non-resolved CT images. This promises improved image quality due to image noise reduction in scans obtained from clinical CT examinations with lowest X-ray tube currents or obese patients. To quantify the benefits of quantum counting detectors in clinical CT we have carried out an extensive simulation study of the complete scanning and reconstruction process for both kinds of detectors. The simulation chain encompasses modeling of the X-ray source, beam attenuation in the patient, and calculation of the detector response. Moreover, in each case the subsequent image preprocessing and reconstruction is modeled as well. The simulation-based, theoretical evaluation is validated by experiments with a novel prototype quantum counting system and a Siemens Definition Flash scanner with a conventional energy integrating CT detector. We demonstrate and quantify the improvement from image noise reduction achievable with quantum counting techniques in CT examinations with ultra-low X-ray dose and strong attenuation.

  17. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  18. Electron Density Calibration for Radiotherapy Treatment Planning

    International Nuclear Information System (INIS)

    Herrera-Martinez, F.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.; Ruiz-Trejo, C.; Celis-Lopez, M. A.; Larraga-Gutierrez, J. M.; Garcia-Garduno, A.

    2006-01-01

    Computed tomography (CT) images are used as basic input data for most modern radiosurgery treatment planning systems (TPS). CT data not only provide anatomic information to delineate target volumes, but also allow the introduction of corrections for tissue inhomogeneities into dose calculations during the treatment planning procedure. These corrections involve the determination of a relationship between tissue electron density (ρe) and their corresponding Hounsfield Units (HU). In this work, an elemental analysis of different commercial tissue equivalent materials using Scanning Electron Microscopy was carried out to characterize their chemical composition. The tissue equivalent materials were chosen to ensure a large range of ρe to be included in the CT scanner calibration. A phantom was designed and constructed with these materials to simulate the size of a human head

  19. Pediatric renal leukemia: spectrum of CT imaging findings

    International Nuclear Information System (INIS)

    Hilmes, Melissa A.; Dillman, Jonathan R.; Mody, Rajen J.; Strouse, Peter J.

    2008-01-01

    The kidneys are a site of extramedullary leukemic disease that can be readily detected by CT. To demonstrate the spectrum of CT findings in children with renal leukemic involvement. Twelve children were identified retrospectively as having renal leukemic involvement by contrast-enhanced CT of the abdomen. Contrast-enhanced CT images through the kidneys of each patient were reviewed by two pediatric radiologists. Pertinent imaging findings and renal lengths were documented. The electronic medical record was accessed to obtain relevant clinical and pathologic information. Five patients with renal leukemic involvement presented with multiple bilateral low-attenuation masses, while three patients demonstrated large areas of wedge-shaped and geographic low attenuation. Four other patients presented with unique imaging findings, including a solitary unilateral low-attenuation mass, solitary bilateral low-attenuation masses, multiple bilateral low-attenuation masses including unilateral large conglomerate masses, and bilateral areas of ill-defined parenchymal low attenuation. Two patients showed unilateral nephromegaly, while eight other patients showed bilateral nephromegaly. Two patients had normal size kidneys. Two patients had elevated serum creatinine concentrations at the time of imaging. Renal leukemic involvement in children can present with a variety of CT imaging findings. Focal renal abnormalities as well as nephromegaly are frequently observed. Most commonly, renal leukemic involvement does not appear to impair renal function. (orig.)

  20. Pediatric renal leukemia: spectrum of CT imaging findings

    Energy Technology Data Exchange (ETDEWEB)

    Hilmes, Melissa A. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); Vanderbilt University Children' s Hospital, Section of Pediatric Radiology, Nashville, TN (United States); Dillman, Jonathan R. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States); University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Mody, Rajen J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Division of Pediatric Hematology-Oncology and Bone Marrow Transplantation, Ann Arbor, MI (United States); Strouse, Peter J. [University of Michigan Health System, C.S. Mott Children' s Hospital, Section of Pediatric Radiology, Ann Arbor, MI (United States)

    2008-04-15

    The kidneys are a site of extramedullary leukemic disease that can be readily detected by CT. To demonstrate the spectrum of CT findings in children with renal leukemic involvement. Twelve children were identified retrospectively as having renal leukemic involvement by contrast-enhanced CT of the abdomen. Contrast-enhanced CT images through the kidneys of each patient were reviewed by two pediatric radiologists. Pertinent imaging findings and renal lengths were documented. The electronic medical record was accessed to obtain relevant clinical and pathologic information. Five patients with renal leukemic involvement presented with multiple bilateral low-attenuation masses, while three patients demonstrated large areas of wedge-shaped and geographic low attenuation. Four other patients presented with unique imaging findings, including a solitary unilateral low-attenuation mass, solitary bilateral low-attenuation masses, multiple bilateral low-attenuation masses including unilateral large conglomerate masses, and bilateral areas of ill-defined parenchymal low attenuation. Two patients showed unilateral nephromegaly, while eight other patients showed bilateral nephromegaly. Two patients had normal size kidneys. Two patients had elevated serum creatinine concentrations at the time of imaging. Renal leukemic involvement in children can present with a variety of CT imaging findings. Focal renal abnormalities as well as nephromegaly are frequently observed. Most commonly, renal leukemic involvement does not appear to impair renal function. (orig.)

  1. TH-CD-202-02: A Preliminary Study Evaluating Beam-Hardening Artifact Reduction On CT Direct Electron-Density Images

    Energy Technology Data Exchange (ETDEWEB)

    Li, H; Dolly, S; Zhao, T; Anastasio, M; Mutic, S [Washington University School of Medicine, Saint Louis, MO (United States); Ritter, A; Colombo, V; Raupach, R; Huenemohr, N [Siemens Healthcare GmbH, Deutschland (Germany); Mistry, N [Siemens Medical Solutions USA, Malvern, PA (United States); Yu, L [Mayo Clinic, Rochester, MN (United States)

    2016-06-15

    Purpose: A prototype reconstruction algorithm that can provide direct electron density (ED) images from single energy CT scans is being currently developed by Siemens Healthcare GmbH. This feature can eliminate the need for kV specific calibration curve for radiation treatemnt planning. An added benefit is that beam-hardening artifacts are also reduced on direct-ED images due to the underlying material decomposition. This study is to quantitatively analyze the reduction of beam-hardening artifacts on direct-ED images and suggest additional clinical usages. Methods: HU and direct-ED images were reconstructed on a head phantom scanned on a Siemens Definition AS CT scanner at five tube potentials of 70kV, 80kV, 100kV, 120kV and 140kV respectively. From these images, mean, standard deviation (SD), and local NPS were calculated for regions of interest (ROI) of same locations and sizes. A complete analysis of beam-hardening artifact reduction and image quality improvement was conducted. Results: Along with the increase of tube potentials, ROI means and SDs decrease on both HU and direct-ED images. The mean value differences between HU and direct-ED images are up to 8% with absolute value of 2.9. Compared to that on HU images, the SDs are lower on direct-ED images, and the differences are up to 26%. Interestingly, the local NPS calculated from direct-ED images shows consistent values in the low spatial frequency domain for images acquired from all tube potential settings, while varied dramatically on HU images. This also confirms the beam -hardening artifact reduction on ED images. Conclusions: The low SDs on direct-ED images and relative consistent NPS values in the low spatial frequency domain indicate a reduction of beam-hardening artifacts. The direct-ED image has the potential to assist in more accurate organ contouring, and is a better fit for the desired purpose of CT simulations for radiotherapy.

  2. An electron beam linear scanning mode for industrial limited-angle nano-computed tomography

    Science.gov (United States)

    Wang, Chengxiang; Zeng, Li; Yu, Wei; Zhang, Lingli; Guo, Yumeng; Gong, Changcheng

    2018-01-01

    Nano-computed tomography (nano-CT), which utilizes X-rays to research the inner structure of some small objects and has been widely utilized in biomedical research, electronic technology, geology, material sciences, etc., is a high spatial resolution and non-destructive research technique. A traditional nano-CT scanning model with a very high mechanical precision and stability of object manipulator, which is difficult to reach when the scanned object is continuously rotated, is required for high resolution imaging. To reduce the scanning time and attain a stable and high resolution imaging in industrial non-destructive testing, we study an electron beam linear scanning mode of nano-CT system that can avoid mechanical vibration and object movement caused by the continuously rotated object. Furthermore, to further save the scanning time and study how small the scanning range could be considered with acceptable spatial resolution, an alternating iterative algorithm based on ℓ0 minimization is utilized to limited-angle nano-CT reconstruction problem with the electron beam linear scanning mode. The experimental results confirm the feasibility of the electron beam linear scanning mode of nano-CT system.

  3. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    International Nuclear Information System (INIS)

    Nakanishi, Tadashi; Hamada, Seiki; Takamiya, Makoto; Kuribayashi, Sachio; Naito, Hiroaki

    1994-01-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  4. Assessment of blood stasis in left-atrial appendage with electron-beam CT: filling delay in atrial fibrillation

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Tadashi [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Hamada, Seiki [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Takamiya, Makoto [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Kuribayashi, Sachio [Dept. of Radiology, National Cardiovascular Center, Suita, Osaka (Japan); Naito, Hiroaki [Biomedical Research Center, Osaka Univ. School of Medicine, Suita (Japan)

    1994-10-01

    The left-atrial appendage (LAA) is the most frequent site of thrombus formation. The most probable reason is its anatomical structure and blood stasis. We hypothesized that peak time delay should occur in the LAA with stagnant blood flow. We measured peak time delay in LAA against left atrium with the flow-mode study of electron-beam CT for 49 patients (including 23 patients with atrial fibrillation [AF]). Volume-mode scannings were also performed to detect intracardiac thrombi. Patients with atrial fibrillation showed a larger value than those with sinus rhythm. Some AF patients with no filling of contrast media into the LAA and/or thrombus showed a larger value than the others. The value obtained by the flow-mode study might have the potential by the flow-mode study might have the potential to assess blood stasis and to predict the jeopardized state in the LAA. (orig.)

  5. The Human Resources Management System: Part 1.

    Science.gov (United States)

    Ceriello, Vincent R.

    1982-01-01

    Presents a systematic and disciplined approach to planning for the development and implementation of an information system which will collect, store, maintain, and report human resources data. Discusses guidelines, priorities, training requirements, security, auditing, interface with payroll, and personnel reporting. (CT)

  6. Computed Tomography (CT) Imaging of Injuries from Blunt Abdominal Trauma: A Pictorial Essay.

    Science.gov (United States)

    Hassan, Radhiana; Abd Aziz, Azian

    2010-04-01

    Blunt abdominal trauma can cause multiple internal injuries. However, these injuries are often difficult to accurately evaluate, particularly in the presence of more obvious external injuries. Computed tomography (CT) imaging is currently used to assess clinically stable patients with blunt abdominal trauma. CT can provide a rapid and accurate appraisal of the abdominal viscera, retroperitoneum and abdominal wall, as well as a limited assessment of the lower thoracic region and bony pelvis. This paper presents examples of various injuries in trauma patients depicted in abdominal CT images. We hope these images provide a resource for radiologists, surgeons and medical officers, as well as a learning tool for medical students.

  7. PET/CT in lymphoma patients; PET-CT bei Lymphompatienten

    Energy Technology Data Exchange (ETDEWEB)

    Steinert, H.C. [Universitaetsspital Zuerich, Klinik und Poliklinik fuer Nuklearmedizin (Switzerland)

    2004-11-01

    First results of PET/CT in Hodgkin's disease (HD) and aggressive non-Hodgkin's lymphoma (NHL) are reported. From March 2001 to August 2004 822 PET/CT were performed at our clinic in lymphoma patients for primary staging, restaging after therapy, and diagnosis of recurrence. For coregistration non contrast-enhanced low-dose CT were used. Due to the exact anatomic localization of {sup 18}F-FDG accumulating lesions equivocal or false positive PET findings are avoided. In comparison to contrast enhanced CT, PET/CT has a higher sensitivity and specificity in patients with HD and aggressive NHL. Integration of PET/CT in treatment planning of radiation therapy optimizes the field volume. Even in the initial phase of clinical evaluation, PET/CT has proven useful in staging and restaging of lymphoma. The exact anatomic localization of the PET findings is essential for a precise report, for treatment planning of radiation therapy, and for planning surgical biopsy. (orig.) [German] Erste Ergebnisse der PET-CT bei Morbus Hodgkin (HD) und den aggressiven Non-Hodgkin-Lymphomen (NHL) werden beschrieben. Von Maerz 2001 bis August 2004 wurden 822 PET-CT bei Lymphompatienten zum primaeren Staging, zum Restaging nach Therapie und zur Rezidivdiagnostik an unserer Klinik durchgefuehrt. Fuer die Koregistration wurde ein Low-dose-CT ohne i.v.-Kontrastmittel verwendet. Durch die exakte anatomische Zuordnung der {sup 18}F-FDG aufnehmenden Laesionen wurden unklare oder falsch-positive PET-Befunde vermieden. Die PET-CT erzielte im Vergleich zur KM-verstaerkten CT eine hoehere Sensitivitaet und Spezifitaet bei Patienten mit HD und aggressiven NHL. Die Integration der PET-CT in die Planung der Strahlentherapie fuehrte zu einer Optimierung der Feldgrenzen. Die PET-CT hat sich bereits in der Phase der initialen klinischen Evaluation als wertvoll beim Staging und Restaging von Lymphomen erwiesen. Die exakte anatomische Zuordnung der PET-Informationen ist fuer eine sichere Befundung

  8. CT of hepatocellular carcinoma. Analysis of contrast-enhanced CT using CT arteriography

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Hori, S; Tokunaga, K; Yoshioka, H [Osaka Univ. (Japan). Faculty of Medicine

    1981-02-01

    Although changes in the CT appearance resulting from contrast enhancement (CE) for hepatocellular carcinoma have been considered in association with vascularity of tumors, no detailed studies have yet been made. We analyzed changes in the CT appearance following CE by comparing with hepatic arteriogram and CT arteriogram (CTA) performed during intraarterial infusion of contrast medium. When tumors showing low density in the plain CT were enhanced by contrast, the results were variable, ranging from intensification of the low density to replacement by high density, and the results were classified into L/sub 0/ to L/sub 3/ according to vascularity of tumors. The results after CE could also be classified into I/sub 0/ to I/sub 3/ when tumors showed isodensity in the plain CT. There was a correlation between vascularity presumed from CE and vascularity by CTA. It may be concluded that tumor vascularity could be estimated by the findings of CE which might indicate a possibility of qualitative diagnosis of tumors.

  9. Low dose CT simulation using experimental noise model

    Energy Technology Data Exchange (ETDEWEB)

    Nakanishi, Satori; Zamyatin, Alexander A. [Toshiba Medical Systems Corporation, Tochigi, Otawarashi (Japan); Silver, Michael D. [Toshiba Medical Research Institute, Vernon Hills, IL (United States)

    2011-07-01

    We suggest a method to obtain system noise model experimentally without relying on assumptions on statistical distribution of the noise; also, knowledge of DAS gain and electronic noise level are not required. Evaluation with ultra-low dose CT data (5 mAs) shows good match between simulated and real data noise. (orig.)

  10. MO-F-CAMPUS-J-04: Tissue Segmentation-Based MR Electron Density Mapping Method for MR-Only Radiation Treatment Planning of Brain

    Energy Technology Data Exchange (ETDEWEB)

    Yu, H [Sunnybrook Health Sciences Centre, Toronto, Ontario (Canada); Lee, Y [Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Ruschin, M [Odette Cancer Centre, Toronto, ON (Canada); Karam, I [Sunnybrook Odette Cancer Center, Toronto, Ontario (Canada); Sahgal, A [University of Toronto, Toronto, ON (Canada)

    2015-06-15

    Purpose: Automatically derive electron density of tissues using MR images and generate a pseudo-CT for MR-only treatment planning of brain tumours. Methods: 20 stereotactic radiosurgery (SRS) patients’ T1-weighted MR images and CT images were retrospectively acquired. First, a semi-automated tissue segmentation algorithm was developed to differentiate tissues with similar MR intensities and large differences in electron densities. The method started with approximately 12 slices of manually contoured spatial regions containing sinuses and airways, then air, bone, brain, cerebrospinal fluid (CSF) and eyes were automatically segmented using edge detection and anatomical information including location, shape, tissue uniformity and relative intensity distribution. Next, soft tissues - muscle and fat were segmented based on their relative intensity histogram. Finally, intensities of voxels in each segmented tissue were mapped into their electron density range to generate pseudo-CT by linearly fitting their relative intensity histograms. Co-registered CT was used as a ground truth. The bone segmentations of pseudo-CT were compared with those of co-registered CT obtained by using a 300HU threshold. The average distances between voxels on external edges of the skull of pseudo-CT and CT in three axial, coronal and sagittal slices with the largest width of skull were calculated. The mean absolute electron density (in Hounsfield unit) difference of voxels in each segmented tissues was calculated. Results: The average of distances between voxels on external skull from pseudo-CT and CT were 0.6±1.1mm (mean±1SD). The mean absolute electron density differences for bone, brain, CSF, muscle and fat are 78±114 HU, and 21±8 HU, 14±29 HU, 57±37 HU, and 31±63 HU, respectively. Conclusion: The semi-automated MR electron density mapping technique was developed using T1-weighted MR images. The generated pseudo-CT is comparable to that of CT in terms of anatomical position of

  11. Daily quality controls analysis of a CT scanner simulator

    International Nuclear Information System (INIS)

    Vasques, Maira Milanelo; Santos, Gabriela R.; Furnari, Laura

    2016-01-01

    With the increasing technological developments, radiotherapy practices, which allow for better involvement of the tumor with the required therapeutic dose and minimize the complications of normal tissues, have become reality in several Radiotherapy services. The use of these resources in turn, was only possible due to the progress made in planning based on digital volumetric images of good quality, such as computed tomography (CT), which allow the correct delimitation of the tumor volume and critical structures. Specific tests for quality control in a CT scanner used in radiotherapy, named CT simulator, should be applied as part of the institutional Quality Assurance Program. This study presents the methodology used in the Instituto de Radiologia do Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo (HCFMUSP) for daily testing of the CT scanner simulator and the results obtained throughout more than two years. The experience gained in the period conducted showed that the tests are easy to perform and can be done in a few minutes by a trained professional. Data analysis showed good reproducibility, which allowed the tests could be performed less frequently, after 16 months of data collection. (author)

  12. Using mobile electronic devices to deliver educational resources in developing countries.

    Science.gov (United States)

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  13. A rigid motion correction method for helical computed tomography (CT)

    International Nuclear Information System (INIS)

    Kim, J-H; Kyme, A; Fulton, R; Nuyts, J; Kuncic, Z

    2015-01-01

    We propose a method to compensate for six degree-of-freedom rigid motion in helical CT of the head. The method is demonstrated in simulations and in helical scans performed on a 16-slice CT scanner. Scans of a Hoffman brain phantom were acquired while an optical motion tracking system recorded the motion of the bed and the phantom. Motion correction was performed by restoring projection consistency using data from the motion tracking system, and reconstructing with an iterative fully 3D algorithm. Motion correction accuracy was evaluated by comparing reconstructed images with a stationary reference scan. We also investigated the effects on accuracy of tracker sampling rate, measurement jitter, interpolation of tracker measurements, and the synchronization of motion data and CT projections. After optimization of these aspects, motion corrected images corresponded remarkably closely to images of the stationary phantom with correlation and similarity coefficients both above 0.9. We performed a simulation study using volunteer head motion and found similarly that our method is capable of compensating effectively for realistic human head movements. To the best of our knowledge, this is the first practical demonstration of generalized rigid motion correction in helical CT. Its clinical value, which we have yet to explore, may be significant. For example it could reduce the necessity for repeat scans and resource-intensive anesthetic and sedation procedures in patient groups prone to motion, such as young children. It is not only applicable to dedicated CT imaging, but also to hybrid PET/CT and SPECT/CT, where it could also ensure an accurate CT image for lesion localization and attenuation correction of the functional image data. (paper)

  14. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  15. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Imaging of head and neck tumors -- methods: CT, spiral-CT, multislice-spiral-CT

    International Nuclear Information System (INIS)

    Baum, Ulrich; Greess, Holger; Lell, Michael; Noemayr, Anton; Lenz, Martin

    2000-01-01

    Spiral-CT is standard for imaging neck tumors. In correspondence with other groups we routinely use spiral-CT with thin slices (3 mm), a pitch of 1.3-1.5 and an overlapping reconstruction increment (2-3 mm). In patients with dental fillings a short additional spiral parallel to the corpus of the mandible reduces artifacts behind the dental arches and improves the diagnostic value of CT. For the assessment of the base of the skull, the orbital floor, the palate and paranasal sinuses an additional examination in the coronal plane is helpful. Secondary coronal reconstructions of axial scans are helpful in the evaluation of the crossing of the midline by small tumors of the tongue base or palate. For an optimal vascular or tissue contrast a sufficient volume of contrast medium and a start delay greater than 70-80 s are necessary. In our opinion the best results can be achieved with a volume of 150 ml, a flow of 2.5 ml/s and a start delay of 80 s. Dynamic enhanced CT is only necessary in some special cases. There is clear indication for dynamic enhanced CT where a glomus tumor is suspected. Additional functional CT imaging during i-phonation and/or Valsalva's maneuver are of great importance to prove vocal cords mobility. Therefore, imaging during i-phonation is an elemental part of every thorough examination of the hypopharynx and larynx region. Multislice-spiral-CT allows almost isotropic imaging of the head and neck region and improves the assessment of tumor spread and lymph node metastases in arbitrary oblique planes. Thin structures (the base of the skull, the orbital floor, the hard palate) as well as the floor of the mouth can be evaluated sufficiently with multiplanar reformations. Usually, additional coronal scanning is not necessary with multislice-spiral-CT. Multislice-spiral-CT is especially advantageous in defining the critical relationships of tumor and lymph node metastases and for functional imaging of the hypopharynx and larynx not only in the

  17. CT of portal vein tumor thrombosis. Usefulness of dynamic CT

    Energy Technology Data Exchange (ETDEWEB)

    Takemoto, Kazumasa; Inoue, Yuichi; Tanaka, Masahiro; Nemoto, Yutaka; Nakamura, Kenji [Osaka City Univ. (Japan). Faculty of Medicine

    1983-08-01

    We evaluated CT findings of portal vein tumor thrombosis in 16 hepatomas by plain, contrast and dynamic CT. Plain and contrast CT findings were an enlargement of the portal vein (81%), intraluminal low density area (63%). Dynamic CT enhanced the diagnostic capability of the tumor thrombus as a relatively low density area because of the marked enhancement of the portal vein. In addition, dynamic CT newly demonstrated hyperdense peripheral ring (35%) and arterio portal shunt (35%). It is advisable to select the scan level to include the portal vein when dynamic CT is performed in the patient of hepatocellular carcinoma.

  18. CT findings of pancreatic carcinoma. Evaluation with the combined method of early enhancement CT and high dose enhancement CT

    International Nuclear Information System (INIS)

    Itoh, Shigeki; Endo, Tokiko; Isomura, Takayuki; Ishigaki, Takeo; Ikeda, Mitsuru; Senda, Kouhei.

    1995-01-01

    Computed tomographic (CT) findings of pancreatic ductal adenocarcinoma were studied with the combined method of early enhancement CT and high dose enhancement CT in 72 carcinomas. Common Findings were change in pancreatic contour, abnormal attenuation in a tumor and dilatation of the main pancreatic duct. The incidence of abnormal attenuation and dilatation of the main pancreatic duct and bile duct was constant regardless of tumor size. The finding of hypoattenuation at early enhancement CT was most useful for demonstrating a carcinoma. However, this finding was negative in ten cases, five of which showed inhomogenous hyperattenuation at high dose enhancement CT. The detection of change in pancreatic contour and dilatation of the main pancreatic duct was most frequent at high dose enhancement CT. The finding of change in pancreatic contour and/or abnormal attenuation in a tumor could be detected in 47 cases at plain CT, 66 at early enhancement CT and 65 at high dose enhancement CT. Since the four cases in which neither finding was detected by any CT method showed dilatated main pancreatic duct, there was no case without abnormal CT findings. This combined CT method will be a reliable diagnostic technique in the imaging of pancreatic carcinoma. (author)

  19. Sensitivity calibration procedures in optical-CT scanning of BANG 3 polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y.; Wuu, Cheng-Shie; Maryanski, Marek J. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States); Department of Radiation Oncology, Columbia University, New York, New York 10032 and MGS Research Inc., Madison, Connecticut 06443 (United States)

    2010-02-15

    The dose response of the BANG 3 polymer gel dosimeter (MGS Research Inc., Madison, CT) was studied using the OCTOPUS laser CT scanner (MGS Research Inc., Madison, CT). Six 17 cm diameter and 12 cm high Barex cylinders, and 18 small glass vials were used to house the gel. The gel phantoms were irradiated with 6 and 10 MV photons, as well as 12 and 16 MeV electrons using a Varian Clinac 2100EX. Three calibration methods were used to obtain the dose response curves: (a) Optical density measurements on the 18 glass vials irradiated with graded doses from 0 to 4 Gy using 6 or 10 MV large field irradiations; (b) optical-CT scanning of Barex cylinders irradiated with graded doses (0.5, 1, 1.5, and 2 Gy) from four adjacent 4x4 cm{sup 2} photon fields or 6x6 cm{sup 2} electron fields; and (c) percent depth dose (PDD) comparison of optical-CT scans with ion chamber measurements for 6x6 cm{sup 2}, 12 and 16 MeV electron fields. The dose response of the BANG 3 gel was found to be linear and energy independent within the uncertainties of the experimental methods (about 3%). The slopes of the linearly fitted dose response curves (dose sensitivities) from the four field irradiations (0.0752{+-}3%, 0.0756{+-}3%, 0.0767{+-}3%, and 0.0759{+-}3% cm{sup -1} Gy{sup -1}) and the PDD matching methods (0.0768{+-}3% and 0.0761{+-}3% cm{sup -1} Gy{sup -1}) agree within 2.2%, indicating a good reproducibility of the gel dose response within phantoms of the same geometry. The dose sensitivities from the glass vial approach are different from those of the cylindrical Barex phantoms by more than 30%, owing probably to the difference in temperature inside the two types of phantoms during gel formation and irradiation, and possible oxygen contamination of the glass vial walls. The dose response curve obtained from the PDD matching approach with 16 MeV electron field was used to calibrate the gel phantom irradiated with the 12 MeV, 6x6 cm{sup 2} electron field. Three-dimensional dose distributions

  20. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  1. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  2. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  3. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  4. Blind CT image quality assessment via deep learning strategy: initial study

    Science.gov (United States)

    Li, Sui; He, Ji; Wang, Yongbo; Liao, Yuting; Zeng, Dong; Bian, Zhaoying; Ma, Jianhua

    2018-03-01

    Computed Tomography (CT) is one of the most important medical imaging modality. CT images can be used to assist in the detection and diagnosis of lesions and to facilitate follow-up treatment. However, CT images are vulnerable to noise. Actually, there are two major source intrinsically causing the CT data noise, i.e., the X-ray photo statistics and the electronic noise background. Therefore, it is necessary to doing image quality assessment (IQA) in CT imaging before diagnosis and treatment. Most of existing CT images IQA methods are based on human observer study. However, these methods are impractical in clinical for their complex and time-consuming. In this paper, we presented a blind CT image quality assessment via deep learning strategy. A database of 1500 CT images is constructed, containing 300 high-quality images and 1200 corresponding noisy images. Specifically, the high-quality images were used to simulate the corresponding noisy images at four different doses. Then, the images are scored by the experienced radiologists by the following attributes: image noise, artifacts, edge and structure, overall image quality, and tumor size and boundary estimation with five-point scale. We trained a network for learning the non-liner map from CT images to subjective evaluation scores. Then, we load the pre-trained model to yield predicted score from the test image. To demonstrate the performance of the deep learning network in IQA, correlation coefficients: Pearson Linear Correlation Coefficient (PLCC) and Spearman Rank Order Correlation Coefficient (SROCC) are utilized. And the experimental result demonstrate that the presented deep learning based IQA strategy can be used in the CT image quality assessment.

  5. CT arterial portography and CT arteriography with a triple-lumen balloon catheter

    International Nuclear Information System (INIS)

    Murakami, T.; Oi, H.; Hori, M.; Kim, T.; Takahashi, S.; Matsushita, M.; Narumi, Y.; Nakamura, H.

    1997-01-01

    Purpose: To evaluate the usefulness of the triple-lumen balloon catheter in the serial performance of CT arterial portography (CT-AP) and CT arteriography (CT-A). Material and Methods: A combined CT-AP and CT-A examination of 58 patients was carried out in which a cobra-type triple-lumen balloon catheter was used. CT-AP was performed by injecting contrast medium either into the splenic artery through a side-hole in the catheter proximal to the balloon inflated in the common hepatic artery, or into the superior mesentric artery through an end-hole in the catheter. Then CT-A was serially performed by delivering contrast medium either to the common hepatic artery or the proper hepatic artery from the end-hole, or to the accessory right hepatic artery through a side-hole proximal to the inflated balloon. Results: Sufficient CT-APs were obtained in 53 of the 58 patients (91%), CT-A in 42 (72%), and both in 42 (72%). Incomplete CT-AP was due to technical failure or anatomical anomaly, as was incomplete CT-A. No complications were seen. (orig.)

  6. CT-Urography; Urografia CT

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, Ludovico; Grotto, Maurizio [Trieste Univ., Trieste (Italy). Dipartimento di scienze cliniche, morfologiche e tecnologiche, UCO di radiologia; Morra, Aldo [CRO, Aviano (Italy). Reparto di radiologia

    2005-09-15

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography. [Italian] Gli Autori presentano una panoramica sulla Urografia TC (Uro TC). L'avvento della TC multistrato e l'evoluzione delle tecniche di elaborazione consentono di ottenere dei quadri urografici ottimali comparativi con quelli convenzionali. Vengono ricordate le varie tecniche di acquisizione e i protocolli usati dai vari Autori. La dose effettiva di radiazioni ha rappresentato uno dei fattori condizionanti per cui oggi prevale l'orientamento di ridurre il numero di scansioni, considerando dopo la scansione senza mezzo di contrasto un'unica scansione contrasto grafica comprendente sia la fase nefrografica che quella urografica. Con l'uso della TC multistrato la qualita dell'urogramma migliora con l'aumento del numero degli strati. Vengono descritte le varie tecniche di elaborazione, la

  7. Preliminary investigations on high energy electron beam tomography

    Energy Technology Data Exchange (ETDEWEB)

    Baertling, Yves; Hoppe, Dietrich; Hampel, Uwe

    2010-12-15

    In computed tomography (CT) cross-sectional images of the attenuation distribution within a slice are created by scanning radiographic projections of an object with a rotating X-ray source detector compound and subsequent reconstruction of the images from these projection data on a computer. CT can be made very fast by employing a scanned electron beam instead of a mechanically moving X-ray source. Now this principle was extended towards high-energy electron beam tomography with an electrostatic accelerator. Therefore a dedicated experimental campaign was planned and carried out at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. There we investigated the capabilities of BINP's accelerators as an electron beam generating and scanning unit of a potential high-energy electron beam tomography device. The setup based on a 1 MeV ELV-6 (BINP) electron accelerator and a single detector. Besides tomographic measurements with different phantoms, further experiments were carried out concerning the focal spot size and repeat accuracy of the electron beam as well as the detector's response time and signal to noise ratio. (orig.)

  8. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  9. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  10. Multi-scale characteristics of coal structure by x-ray computed tomography (x-ray CT), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP)

    Science.gov (United States)

    Cai, Ting-ting; Feng, Zeng-chao; Zhou, Dong

    2018-02-01

    It is of great benefit to study the material and structural heterogeneity of coal for better understanding the coalbed methane (CBM) storage and enrichment. In this paper, multi-scale X-ray computed tomography (CT), scanning electron microscope (SEM) and mercury intrusion porosimetry (MIP) at multi scales were conducted to thoroughly study the material distribution, heterogeneity, pore development, porosity and permeability of coal. It is suitable and reasonable to divide the testing samples into three structural categories by average density and heterogeneity degree, and the meso structure in the three categories accords with the morphology on SEM images. The pore size distribution and pore development of each subsample cannot be correspondingly related to their respective structure category or morphology due to different observation scales, while the macro pore size development, accumulated macro pore volume and macro pores porosity accord with the meso structure category and morphology information by CT and SEM at the same scale very well. Given the effect of macro pores on permeability and the contribution of micro pores to CBM storage capacity, reservoirs with developed micro pores and macro pores may be the most suitable coal reservoir for CBM exploitation.

  11. Optimization of Protocol CT, PET-CT, whole body; Optimizacion de protocolo CT, en PET-CT, de cuerpo entero

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Fredys Santos, E-mail: fsantos@ccss.sa.cr [Caja Costarricense de Seguro Social (ACCPR/CCSS), San Jose (Costa Rica). Area Control de Calidade Y Proteccion Radiologica; Namias, Mauro, E-mail: mnamias@gmail.com [Comision Nacional de Energia Atomica (FCDN/CNEA), Buenos Aires (Argentina). Fundacion Centro Diagnostico Nuclear

    2013-11-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study.

  12. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  13. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

    International Nuclear Information System (INIS)

    Xu, Yonghua; Cai, Wenli; Nappi, Janne; Yoshida, Hiro

    2012-01-01

    Purpose: To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Materials and methods: Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Results: Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p < 0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9 mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4 mm increased to 84% (31/37). Conclusions: The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4 mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.

  14. Experimental validation of incomplete data CT image reconstruction techniques

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Hsiao, M.L.; Tam, K.C.

    1989-01-01

    X-ray CT inspection of large metal parts is often limited by x-ray penetration problems along many of the ray paths required for a complete CT data set. In addition, because of the complex geometry of many industrial parts, manipulation difficulties often prevent scanning over some range of angles. CT images reconstructed from these incomplete data sets contain a variety of artifacts which limit their usefulness in part quality determination. Over the past several years, the authors' company has developed 2 new methods of incorporating a priori information about the parts under inspection to significantly improve incomplete data CT image quality. This work reviews the methods which were developed and presents experimental results which confirm the effectiveness of the techniques. The new methods for dealing with incomplete CT data sets rely on a priori information from part blueprints (in electronic form), outer boundary information from touch sensors, estimates of part outer boundaries from available x-ray data, and linear x-ray attenuation coefficients of the part. The two methods make use of this information in different fashions. The relative performance of the two methods in detecting various flaw types is compared. Methods for accurately registering a priori information with x-ray data are also described. These results are critical to a new industrial x-ray inspection cell built for inspection of large aircraft engine parts

  15. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Directory of Open Access Journals (Sweden)

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  16. Trends in CT Request and Related Outcomes in a Pediatric Emergency Department

    Directory of Open Access Journals (Sweden)

    S.M. Saiful Islam

    2016-09-01

    Full Text Available Objectives: To study and to establish the overall trends of computed tomography (CT use and associated outcomes in the pediatric emergency department (PED at Royal Hospital, Oman, from 2010 to 2014. Methods: The hospital electronic medical record was retrospectively searched to find children (from birth to 12 years old who had visited the PED and the number of CT requests between 1 January 2010 and 31 December 2014. The types of CT examinations ordered were analyzed according to anatomical location and were as follows; head, abdomen/pelvis, chest, cervical spine/neck, and others. Results: There were a total of 67 244 PED visits during the study period, 569 of which received 642 CT scans. There was a remarkable rise in CT uses per 1000 visits from 7 in 2010 to 12 in 2014. There was a 56% hike in CT requests from 87 in 2010 to 175 in 2014 while the number of pediatric emergency visits rose by about 28% from 11 721 to 15 052. Although head CT scans were the most common, cervical spine CT scans had the highest rate of increase (600% followed by the chest (112%, head (54% and abdomen (13%. There were no significant changes in other CT scan requests. The cost of CT scans increased from $18 096 to $36 400 during the study period, which increased the average PED cost by about $2 per visit. The average time between a CT being requested and then performed was 1.24 hours. Conclusions: CT use in the pediatric emergency department has risen significantly at a rate that markedly exceeds the growth of emergency visits. This is associated with an increase in PED costs and longer waiting times.

  17. CT of laryngotracheal trauma

    International Nuclear Information System (INIS)

    Lupetin, A.R.; Daffner, R.H.

    1991-01-01

    This paper evaluates the usefulness of CT for the diagnosis of traumatic laryngotracheal abnormalities. The authors retrospectively evaluated the neck CT studies of 50 patients (36 males, 14 females; age range, 16-75 years) who presented to a level I trauma center after suffering a blunt or penetrating laryngotracheal injury. CT results were correlated with endoscopic or surgical findings in 43 cases. Three groups emerge. CT positive: hyloid bone or laryngotracheal cartilage injury; CT positive: soft-tissue injury only; and CT negative. In group 1, CT demonstrated all bony or cartilaginous injuries proved at surgery or suggested at endoscopy. CT failed to demonstrate laryngotracheal separation in 1 case. In group 2, CT demonstrated all soft-tissue injuries suggested at endoscopy. In group 3, CT findings agreed with those of endoscopy in 7 cases, but minor soft-tissue findings seen at endoscopy were missed in 3 cases. Seven patients were studied only with CT. Ct is an accurate technique for detecting bony or cartilaginous laryngotracheal traumatic abnormalities. However, laryngotracheal separation and minor soft-tissue injuries can be missed

  18. The Road to the Common PET/CT Detector

    Science.gov (United States)

    Nassalski, Antoni; Moszynski, Marek; Szczesniak, Tomasz; Wolski, Dariusz; Batsch, Tadeusz

    2007-10-01

    Growing interest in the development of dual modality positron emission/X-rays tomography (PET/CT) systems prompts researchers to face a new challenge: to acquire both the anatomical and functional information in the same measurement, simultaneously using the same detection system and electronics. The aim of this work was to study a detector consisting of LaBr3, LSO or LYSO pixel crystals coupled to an avalanche photodiode (APD). The measurements covered tests of the detectors in PET and CT modes, respectively. The measurements included the determination of light output, energy resolution, the non-proportionality of the light yield and the time resolution for 511 keV annihilation quanta; analysis also included characterizing the PET detector, and determining the dependence of counting rate versus mean current of the APD in the X-ray detection. In the present experiment, the use of counting and current modes in the CT detection increases the dynamic range of the measured dose of X-rays by a factor of 20, compared to the counting mode alone.

  19. CT-Urography

    International Nuclear Information System (INIS)

    Dalla Palma, Ludovico; Grotto, Maurizio; Morra, Aldo

    2005-01-01

    In this paper we present an overview of CT-Urography. With the advent of multislice CT scanners and the evolution of image processing methods this technique now affords optimal urographic images comparable to those obtained with conventional techniques. We describe the acquisition techniques and protocols used by the various authors. Effective radiation dose has conditioned the use of CT-Urography so that the tendency today is to reduce the number of scans by performing, after the non enhanced scan, a single contrast-enhanced scan comprising both the nephrographic and urographic phase. With the use of multislice CT the quality of the urogram improves with the number of slices. We illustrate a variety of processing techniques, multiplanar reconstruction (MPR), maximum (MIP) and average intensity projection (AIP) and volume rendering (VR) and present a series of upper urinary tract tumours testifying to the superiority of the AIP technique over MIP. We then review the results of comparative studies of CT-Urography with conventional urography in upper urinary tract diagnostics. Finally, we describe the advantages and limitations of CT-Urography [it

  20. CT vs 68Ge attenuation correction in a combined PET/CT system: evaluation of the effect of lowering the CT tube current

    International Nuclear Information System (INIS)

    Kamel, Ehab; Hany, Thomas F.; Burger, Cyrill; Treyer, Valerie; Schulthess von, Gustav K.; Buck, Alfred; Lonn, Albert H.R.

    2002-01-01

    With the introduction of combined positron emission tomography/computed tomography (PET/CT) systems, several questions have to be answered. In this work we addressed two of these questions: (a) to what value can the CT tube current be reduced while still yielding adequate maps for the attenuation correction of PET emission scans and (b) how do quantified uptake values in tumours derived from CT and germanium-68 attenuation correction compare. In 26 tumour patients, multidetector CT scans were acquired with 10, 40, 80 and 120 mA (CT 10 , CT 40 , CT 80 and CT 120 ) and used for the attenuation correction of a single FDG PET emission scan, yielding four PET scans designated PET CT10 -PET CT120 . In 60 tumorous lesions, FDG uptake and lesion size were quantified on PET CT10 -PET CT120 . In another group of 18 patients, one CT scan acquired with 80 mA and a standard transmission scan acquired using 68 Ge sources were employed for the attenuation correction of the FDG emission scan (PET CT80 , PET 68Ge ). Uptake values and lesion size in 26 lesions were compared on PET CT80 and PET 68Ge . In the first group of patients, analysis of variance revealed no significant effect of CT current on tumour FDG uptake or lesion size. In the second group, tumour FDG uptake was slightly higher using CT compared with 68 Ge attenuation correction, especially in lesions with high FDG uptake. Lesion size was similar on PET CT80 and PET 68Ge . In conclusion, low CT currents yield adequate maps for the attenuation correction of PET emission scans. Although the discrepancy between CT- and 68 Ge-derived uptake values is probably not relevant in most cases, it should be kept in mind if standardised uptake values derived from CT and 68 Ge attenuation correction are compared. (orig.)

  1. Electron-beam CT coronary angiography in the patients with high heart rate arrhythmia or pacemaker

    International Nuclear Information System (INIS)

    Dong Zhi; Zhu Jiemin; Liu Zhe; Liu Junbo; Li Youjie; Qi Ji

    2006-01-01

    Objective: To report the clinical applicability of coronary angiography for patients with high heart rate, arrhythmia or cardiac pacing using the new-generation of electron-beam CT (e-Speed). Methods: EBCT (GE e-Speed) coronary angiography was performed in 36 eases (male 27, female 9, mean age 58), including the heart rate more than 90 bpm in 20 patients, frequent ectopic beats in 11 cases, implantation of cardiac pacemaker in 4 patients and the unacceptable MSCT image quality due to variability of interscan heart rate (from 82 bpm to 104 bpm) in 1 case. After volume data set was acquired using spiral mode with prospective ECG-gating, the reconstructions of MIP, CPR, VR and Cine were performed. The VR quality was evaluated using a five-point scale. Results: The quality of coronary imaging in all of 36 cases were acceptable. The total visualization rate of coronary artery branches was 80.0%. Left main, left anterior artery and right coronary artery were visualized in all patients and in 94.3% of all cases circumflex artery were visible. Conclusion: EBCT (e-Speed) is applicable in noninvasive coronary angiography for patients with high heart rate, arrhythmia or implanted cardiac pacemaker', and this examination can obtain satisfied diagnosis. (authors)

  2. The role of pubic symphyseal CT arthrography in the imaging of athletic pubalgia.

    Science.gov (United States)

    McArthur, Tatum A; Narducci, Carl A; Lopez-Ben, Robert R

    2014-11-01

    The purpose of this article is to describe the results of pubic symphyseal CT arthrography compared with MRI in patients with suspected athletic pubalgia. In this study, two musculoskeletal radiologists retrospectively searched our department's PACS to identify patients who had undergone CT-guided injection with concurrent pubic symphyseal CT arthrography for evaluation and treatment of groin pain, sports hernia, or athletic pubalgia over a 5.5-year period (January 1, 2007-July 1, 2012). The MR and CT arthrography images and reports, clinical findings at presentation, pain response to injection, and operative findings were reviewed using the electronic medical record. Twelve patients underwent CT-guided injection and pubic symphyseal CT arthrography at our institution during the 5.5-year study period. Nine of the 12 patients had undergone MRI before the procedure. In two of the three patients who had not undergone MRI, CT arthrography revealed secondary clefts. Three of four patients who had secondary clefts on MRI had contrast extravasation reproducing the cleft at CT. Three patients had MRI findings suggestive of athletic pubalgia without MRI evidence of a secondary cleft; in all three of these patients, CT arthrography showed a secondary cleft. In four patients, CT arthrography revealed tendon tears at the adductor origin that were not apparent on MRI. All 12 patients reported decreased groin pain after injection. Pubic symphyseal CT arthrography is a useful technique for the diagnosis and short-term pain relief of athletic pubalgia. It can be used to identify secondary clefts and to detect tendon tears that can potentially be overlooked on MRI.

  3. Computed tomography as a source of electron density information for radiation treatment planning

    International Nuclear Information System (INIS)

    Skrzynski, Witold; Slusarczyk-Kacprzyk, Wioletta; Bulski, Wojciech; Zielinska-Dabrowska, Sylwia; Wachowicz, Marta; Kukolowicz, Pawel F.

    2010-01-01

    Purpose: to evaluate the performance of computed tomography (CT) systems of various designs as a source of electron density (ρ el ) data for treatment planning of radiation therapy. Material and methods: dependence of CT numbers on relative electron density of tissue-equivalent materials (HU-ρ el relationship) was measured for several general-purpose CT systems (single-slice, multislice, wide-bore multislice), for radiotherapy simulators with a single-slice CT and kV CBCT (cone-beam CT) options, as well as for linear accelerators with kV and MV CBCT systems. Electron density phantoms of four sizes were used. Measurement data were compared with the standard HU-ρ el relationships predefined in two commercial treatment-planning systems (TPS). Results: the HU-ρ el relationships obtained with all of the general-purpose CT scanners operating at voltages close to 120 kV were very similar to each other and close to those predefined in TPS. Some dependency of HU values on tube voltage was observed for bone-equivalent materials. For a given tube voltage, differences in results obtained for different phantoms were larger than those obtained for different CT scanners. For radiotherapy simulators and for kV CBCT systems, the information on ρ el was much less precise because of poor uniformity of images. For MV CBCT, the results were significantly different than for kV systems due to the differing energy spectrum of the beam. Conclusion: the HU-ρ el relationships predefined in TPS can be used for general-purpose CT systems operating at voltages close to 120 kV. For nontypical imaging systems (e.g., CBCT), the relationship can be significantly different and, therefore, it should always be measured and carefully analyzed before using CT data for treatment planning. (orig.)

  4. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.; Ganzkoerper-Computertomographie. Spiral- und Multislice-CT

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-07-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  5. Image Registration for PET/CT and CT Images with Particle Swarm Optimization

    International Nuclear Information System (INIS)

    Lee, Hak Jae; Kim, Yong Kwon; Lee, Ki Sung; Choi, Jong Hak; Kim, Chang Kyun; Moon, Guk Hyun; Joo, Sung Kwan; Kim, Kyeong Min; Cheon, Gi Jeong

    2009-01-01

    Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  6. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  7. The effect of the cranial bone CT numbers on the brain CT numbers

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Hitoshi; Kobayashi, Shotai; Koide, Hiromi; Yamaguchi, Shuhei; Okada, Kazunori; Shimote, Koichi; Tsunematsu, Tokugoro (Shimane Medical Univ., Izumo (Japan))

    1989-06-01

    The effects of the cranial size and the computed tomography (CT) numbers of the cranial bone on that of the brain were studied in 70 subjects, aged from 30 to 94 years. The subjects had no histories of cerebrovascular accidents and showed no abnormalities in the central nervous system upon physical examinations and a CT scan. We measured the average attenuation values (CT numbers) of each elliptical region (165 pixels, 0.39 cm{sup 2}) at the bilateral thalamus and at twelve areas of the deep white matter. Multiple regression analysis was used to assess the effects of age, cranial size, and cranial bone CT numbers on the brain CT numbers. The effect of the cranial bone CT numbers on the brain CT numbers was statistically significant. The brain CT numbers increased with the increase in the cranial bone CT numbers. There was, however, no significant correlation between brain CT numbers and cranial size. In measuring the brain CT numbers, it is desirable that consideration be given to the cranial bone CT numbers. (author).

  8. Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.

    Science.gov (United States)

    Parsa, Azin; Ibrahim, Norliza; Hassan, Bassam; van der Stelt, Paul; Wismeijer, Daniel

    2015-01-01

    The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P micro-CT BV/TV (P = 0.147). An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site. © 2013 John Wiley & Sons A/S. Published by

  9. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  10. The role of taxonomies in social media and the semantic web for health education. A study of SNOMED CT terms in YouTube health video tags.

    Science.gov (United States)

    Konstantinidis, S; Fernandez-Luque, L; Bamidis, P; Karlsen, R

    2013-01-01

    An increasing amount of health education resources for patients and professionals are distributed via social media channels. For example, thousands of health education videos are disseminated via YouTube. Often, tags are assigned by the disseminator. However, the lack of use of standardized terminologies in those tags and the presence of misleading videos make it particularly hard to retrieve relevant videos. i) Identify the use of standardized medical thesauri (SNOMED CT) in YouTube Health videos tags from preselected YouTube Channels and demonstrate an information technology (IT) architecture for treating the tags of these health (video) resources. ii) Investigate the relative percentage of the tags used that relate to SNOMED CT terms. As such resources may play a key role in educating professionals and patients, the use of standardized vocabularies may facilitate the sharing of such resources. iii) Demonstrate how such resources may be properly exploited within the new generation of semantically enriched content or learning management systems that allow for knowledge expansion through the use of linked medical data and numerous literature resources also described through the same vocabularies. We implemented a video portal integrating videos from 500 US Hospital channels. The portal integrated 4,307 YouTube videos regarding surgery as described by 64,367 tags. BioPortal REST services were used within our portal to match SNOMED CT terms with YouTube tags by both exact match and non-exact match. The whole architecture was complemented with a mechanism to enrich the retrieved video resources with other educational material residing in other repositories by following contemporary semantic web advances, in the form of Linked Open Data (LOD) principles. The average percentage of YouTube tags that were expressed using SNOMED CT terms was about 22.5%, while one third of YouTube tags per video contained a SNOMED CT term in a loose search; this analogy became one tenth in

  11. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  12. Virtual colonoscopy with electron beam CT: correlation with barium enema, colonoscopy and pathology

    International Nuclear Information System (INIS)

    Hong, Hye Suk; Kim, Min Jung; Chung, Jae Joon; Kim, Myeong Jin; Lee, Jong Tae; Yoo, Hyung Sik

    1998-01-01

    To perform virtual colonoscopy using electron beam tomography(EBT) in patients in whom a colonic mass was present, and to compare the results with those obtained using barium enema, colonoscopy and gross pathologic specimens. Materials and Methods : Ten patients in whom colonic masses were diagnosed by either barium enema or colonoscopy were involved in this study. There were nine cases of adenocarcinoma and one of tubulovillous adenoma. Using EBT preoperative abdominopelvic CT scans were performed. Axial scans were then three-dimensionally reconstructed to produce virtual colonoscopic images and were compared with barium enema, colonoscopy and gross pathologic specimens. Virtual colonoscopic images of the masses were classified as either 1)polyploid, 2)sessile,3)fungating, or 4)annular constrictive. We also determined whether ulcers were present within the lesions and whether there was obstruction. Results : After virtual colonoscopy, two lesions were classified as polyploid, one as sessile, five as fungating and two as annular constrictive. Virtual colonoscopic images showed good correlation with the findings of barium enema, colonoscopy and gross pathologic specimens. Three of six ulcerative lesions were observed on colonoscopy; in seven adenocarcinomas with partial or total luminal obstruction, virtual colonoscopy visualized the colon beyond the obstructed sites. In one case, barium contrast failed to pass through the obstructed portion and in six cases, the colonoscope similarly failed. Conclusion : Virtual colonoscopies correlated well with barium enema, colonoscopy and gross pathologic specimens. They provide three dimensional images of colonic masses and are helpful for the evaluation of obstructive lesions

  13. Picture analysis in CT-HF and its CT photographs

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Kohirasawa, Hideo; Shinojima, Masayasu; Tokui, Mitsuru; Seo, Kunihiko.

    1980-01-01

    CT (computed tomography) apparatus is rarely used yet in the field of dentistry, though it seems useful. It is possibly because of the artefacts caused by the metallic parts attached to teeth, the large partial volume effect due to many bones and the problems of positioning and reproducibility. After considering the various requirements of the CT apparatuses in dental field, CT-HF (of T/R type) was chosen as such apparatus, and installed as the first in dentistry. In the CT-HF apparatus, the inner diameter of the gantry is up to 300 mm, and the position of a tomographic plane is only 40 mm away from the front of gantry. Mainly the usefulness of scanography in positioning and the usefulness of the CT apparatus in the picture analysis and processing in dental field are described. (J.P.N.)

  14. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  15. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  16. Definition of postlumpectomy tumor bed for radiotherapy boost field planning: CT versus surgical clips

    International Nuclear Information System (INIS)

    Goldberg, Hadassah; Prosnitz, Robert G.; Olson, John A.; Marks, Lawrence B.

    2005-01-01

    Purpose: To compare the location and extent of the tumor bed as defined by surgical clips and computed tomography (CT) scans, after lumpectomy, for electron boost planning as part of breast radiotherapy. Methods and Materials: Planning CT images of 31 operated breasts in 30 patients who underwent lumpectomy were reviewed. One or more clips were placed in the lumpectomy cavity. Serial CT images were used to measure the depth and transverse and longitudinal dimensions. The area and geometric center of the tumor bed were defined by the clips and CT. Results: The CT and clip measurements were identical for the maximal tumor depth in 27 of 30 patients. The CT bed extended beyond the clips by 0-7 mm medially in the transverse/longitudinal extent (multiclip patients). The median distance between the geometric centers in the coronal plane for the tumor bed center was larger for patients with single clips than for those with multiple clips (p 2 . The CT bed was more readily visible in patients with a shorter interval between surgery and radiotherapy. Conclusion: The maximal depth of the tumor bed was similar using the two methods. The extent and centers of the clip-and CT-determined beds differed significantly. This may indicate an underestimation of the tumor bed as defined by clips only and justifies integration of CT information in boost field planning

  17. Clinical applications of SPECT/CT: New hybrid nuclear medicine imaging system

    International Nuclear Information System (INIS)

    2008-08-01

    Interest in multimodality imaging shows no sign of subsiding. New tracers are spreading out the spectrum of clinical applications and innovative technological solutions are preparing the way for yet more modality marriages: hybrid imaging. Single photon emission computed tomography (SPECT) has enabled the evaluation of disease processes based on functional and metabolic information of organs and cells. Integration of X ray computed tomography (CT) into SPECT has recently emerged as a brilliant diagnostic tool in medical imaging, where anatomical details may delineate functional and metabolic information. SPECT/CT has proven to be valuable in oncology. For example, in the case of a patient with metastatic thyroid cancer, neither SPECT nor CT alone could identify the site of malignancy. SPECT/CT, a hybrid image, precisely identified where the surgeon should operate. However SPECT/CT is not just advantageous in oncology. It may also be used as a one-stop-shop for various diseases. Clinical applications with SPECT/CT have started and expanded in developed countries. It has been reported that moving from SPECT alone to SPECT/CT could change diagnoses in 30% of cases. Large numbers of people could therefore benefit from this shift all over the world. This report presents an overview of clinical applications of SPECT/CT and a relevant source of information for nuclear medicine physicians, radiologists and clinical practitioners. This information may also be useful for decision making when allocating resources dedicated to the health care system, a critical issue that is especially important for the development of nuclear medicine in developing countries. In this regard, the IAEA may be heavily involved in the promotion of programmes aimed at the IAEA's coordinated research projects and Technical Cooperation projects

  18. Ultrafast Photoinduced Electron Transfer in a π-Conjugated Oligomer/Porphyrin Complex

    KAUST Repository

    Aly, Shawkat Mohammede

    2014-10-02

    Controlling charge transfer (CT), charge separation (CS), and charge recombination (CR) at the donor-acceptor interface is extremely important to optimize the conversion efficiency in solar cell devices. In general, ultrafast CT and slow CR are desirable for optimal device performance. In this Letter, the ultrafast excited-state CT between platinum oligomer (DPP-Pt(acac)) as a new electron donor and porphyrin as an electron acceptor is monitored for the first time using femtosecond (fs) transient absorption (TA) spectroscopy with broad-band capability and 120 fs temporal resolution. Turning the CT on/off has been shown to be possible either by switching from an organometallic oligomer to a metal-free oligomer or by controlling the charge density on the nitrogen atom of the porphyrin meso unit. Our time-resolved data show that the CT and CS between DPP-Pt(acac) and cationic porphyrin are ultrafast (approximately 1.5 ps), and the CR is slow (ns time scale), as inferred from the formation and the decay of the cationic and anionic species. We also found that the metallic center in the DPP-Pt(acac) oligomer and the positive charge on the porphyrin are the keys to switching on/off the ultrafast CT process.

  19. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  20. High-energy x-ray CT and its application for digital engineering

    International Nuclear Information System (INIS)

    Kamimura, H.; Sadaoka, N.

    2005-01-01

    A high-energy x-ray computed tomography system and x-ray CT data handling software have been developed for digital engineering; internal dimension measurement, density analysis, actual and designed shape comparison, STL file generation, and support for reverse engineering and rapid prototyping. The system is designed to collect accurate images in short scanning time (10 s per section) using a MeV-energy electron linear accelerator and highly sensitive semiconductor detectors in order to scan large objects made of aluminum and/or iron. An excellent environment in digital engineering is provided by the software products; 'StereoCooker' for 3D bitmap CAD (rendering, feature extraction, dimensional measurement, and shape comparison, etc.), 'FeatureMaker' for translating bitmap CT data to CAD data including feature information, and 'Wingware' for realizing an Windows PC cluster system 'WINGluster' to apply CT data analysis. (author)

  1. First experience with multidetector-CT for the diagnosis of coronary atherosclerosis

    International Nuclear Information System (INIS)

    Becker, C.R.; Hong, C.; Schoepf, U.J.; Reiser, M.F.; Knez, A.; Leber, A.; Treede, H.; Wildhirt, S.; Ohnesorge, B.; Flohr, T.

    2000-01-01

    Purpose: Multirow-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries. Methods: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate. Results: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59±8 beats per minute. Conclusion: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries. (orig.) [de

  2. Metal artifact reduction of CT scans to improve PET/CT

    NARCIS (Netherlands)

    Van Der Vos, Charlotte S.; Arens, Anne I.J.; Hamill, James J.; Hofmann, Christian; Panin, Vladimir Y.; Meeuwis, Antoi P.W.; Visser, Eric P.; De Geus-Oei, Lioe Fee

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  3. Metal Artifact Reduction of CT Scans to Improve PET/CT

    NARCIS (Netherlands)

    Vos, C.S. van der; Arens, A.I.J.; Hamill, J.J.; Hofmann, C.; Panin, V.Y.; Meeuwis, A.P.W.; Visser, E.P.; Geus-Oei, L.F. de

    2017-01-01

    In recent years, different metal artifact reduction methods have been developed for CT. These methods have only recently been introduced for PET/CT even though they could be beneficial for interpretation, segmentation, and quantification of the PET/CT images. In this study, phantom and patient scans

  4. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  5. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Mohd Fahmi Mohd, E-mail: mfahmi@usm.my; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz [School of Physics, Universiti Sains Malaysia, 11800 Penang (Malaysia); Bauk, Sabar [School of Distance Education, Universiti Sains Malaysia, 11800 Penang (Malaysia); Hashim, Rokiah [School of Industrial Technologies, Universiti Sains Malaysia, 11800 Penang (Malaysia)

    2015-04-29

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ{sup 2} value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ{sup 2} value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies.

  6. Determination of CT number and density profile of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using computed tomography imaging and electron density phantom

    International Nuclear Information System (INIS)

    Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz; Bauk, Sabar; Hashim, Rokiah

    2015-01-01

    Plug density phantoms were constructed in accordance to CT density phantom model 062M CIRS using binderless, pre-treated and tannin-based Rhizophora Spp. particleboards. The Rhizophora Spp. plug phantoms were scanned along with the CT density phantom using Siemens Somatom Definition AS CT scanner at three CT energies of 80, 120 and 140 kVp. 15 slices of images with 1.0 mm thickness each were taken from the central axis of CT density phantom for CT number and CT density profile analysis. The values were compared to water substitute plug phantom from the CT density phantom. The tannin-based Rhizophora Spp. gave the nearest value of CT number to water substitute at 80 and 120 kVp CT energies with χ 2 value of 0.011 and 0.014 respectively while the binderless Rhizphora Spp. gave the nearest CT number to water substitute at 140 kVp CT energy with χ 2 value of 0.023. The tannin-based Rhizophora Spp. gave the nearest CT density profile to water substitute at all CT energies. This study indicated the suitability of Rhizophora Spp. particleboard as phantom material for the use in CT imaging studies

  7. CT and PET-CT of a Dog with Multiple Pulmonary Adenocarcinoma

    Science.gov (United States)

    KIM, Jisun; KWON, Seong Young; CENA, Rohani; PARK, Seungjo; OH, Juyeon; OUI, Heejin; CHO, Kyoung-Oh; MIN, Jung-Joon; CHOI, Jihye

    2013-01-01

    ABSTRACT A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog’s euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors’ knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors. PMID:24389742

  8. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Directory of Open Access Journals (Sweden)

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  9. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  10. Low-dose non-enhanced CT versus full-dose contrast-enhanced CT in integrated PET/CT studies for the diagnosis of uterine cancer recurrence

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, Kazuhiro [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Suzuki, Kayo [Institute of Biomedical Research and Innovation, Department of PET Diagnosis, Kobe (Japan); Nakamoto, Yuji [Kyoto University Hospital, Department of Diagnostic Radiology, Kyoto (Japan); Onishi, Yumiko; Sakamoto, Setsu; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Senda, Michio [Institute of Biomedical Research and Innovation, Department of Molecular Imaging, Kobe (Japan); Kita, Masato [Kobe City Medical Center General Hospital, Department of Obstetrics and Gynecology, Kobe (Japan)

    2010-08-15

    To evaluate low-dose non-enhanced CT (ldCT) and full-dose contrast-enhanced CT (ceCT) in integrated {sup 18}F-fluorodeoxyglucose (FDG) PET/CT studies for restaging of uterine cancer. A group of 100 women who had undergone treatment for uterine cervical (n=55) or endometrial cancer (n=45) underwent a conventional PET/CT scans with ldCT, and then a ceCT scan. Two observers retrospectively reviewed and interpreted the PET/ldCT and PET/ceCT images in consensus using a three-point grading scale (negative, equivocal, or positive) per patient and per lesion. Final diagnoses were obtained by histopathological examination, or clinical follow-up for at least 6 months. Patient-based analysis showed that the sensitivity, specificity and accuracy of PET/ceCT were 90% (27/30), 97% (68/70) and 95% (95/100), respectively, whereas those of PET/ldCT were 83% (25/30), 94% (66/70) and 91% (91/100), respectively. Sensitivity, specificity and accuracy did not significantly differ between two methods (McNemar test, p=0.48, p=0.48, and p=0.13, respectively). There were 52 sites of lesion recurrence: 12 pelvic lymph node (LN), 11 local recurrence, 8 peritoneum, 7 abdominal LN, 5 lung, 3 supraclavicular LN, 3 liver, 2 mediastinal LN, and 1 muscle and bone. The grading results for the 52 sites of recurrence were: negative 5, equivocal 0 and positive 47 for PET/ceCT, and negative 5, equivocal 4 and positive 43 for PET/ldCT, respectively. Four equivocal regions by PET/ldCT (local recurrence, pelvic LN metastasis, liver metastasis and muscle metastasis) were correctly interpreted as positive by PET/ceCT. PET/ceCT is an accurate imaging modality for the assessment of uterine cancer recurrence. Its use reduces the frequency of equivocal interpretations. (orig.)

  11. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  12. Spinal CT scan, 1

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Methods of CT of the cervical and thoracic spines were explained, and normal CT pictures of them were described. Spinal CT was evaluated in comparison with other methods in various spinal diseases. Plain CT revealed stenosis due to spondylosis or ossification of posterior longitudinal ligament and hernia of intervertebral disc. CT took an important role in the diagnosis of spinal cord tumors with calcification and destruction of the bone. CT scan in combination with other methods was also useful for the diagnosis of spinal injuries, congenital anomalies and infections. (Ueda, J.)

  13. Optimization of Protocol CT, PET-CT, whole body

    International Nuclear Information System (INIS)

    Gutierrez, Fredys Santos; Namias, Mauro

    2013-01-01

    The objective of this study was to optimize the acquisition protocols and processing existing of the CT PET/CT scanner for clinical use of Nuclear Diagnostic Center Foundation, a way to minimize the radiation dose while maintaining diagnostic image quality properly. Dosimetric data of PET / CT service were surveyed and obtained the baseline against which we compare and define strategies and modifications to develop online. We selected transaxial up to the pulmonary hilum and liver slices as the anatomical regions of interest that led to the standardization of the study

  14. A new timing detector for the CT-PPS project

    Energy Technology Data Exchange (ETDEWEB)

    Arcidiacono, R. [INFN – Torino (Italy); Università del Piemonte Orientale (Italy)

    2017-02-11

    The CT-PPS detector will be installed close to the beam line on both sides of CMS, 200 m downstream the interaction point. This detector will measure forward scattered protons, allowing detailed studies of diffractive hadron physics and Central Exclusive Production. The main components of the CT-PPS detector are a silicon tracking system and a timing system. In this contribution we present the proposal of an innovative solution for the timing system, based on Ultra-Fast Silicon Detectors (UFSD). UFSD are a novel concept of silicon detectors potentially able to obtain the necessary time resolution (∼20 ps on the proton arrival time). The use of UFSD has also other attractive features as its material budget is small and the pixel geometries can be tailored to the precise physics distribution of protons. UFSD prototypes for CT-PPS have been designed by CNM (Barcelona) and FBK (Trento): we will present the status of the sensor productions and of the low-noise front-end electronics currently under development and test.

  15. Usefulness of multi-plane dynamic subtraction CT (MPDS-CT) for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Kumazaki, Tatsuo [Nippon Medical School, Tokyo (Japan)

    1996-02-01

    We present a new CT technique using the high speed CT scanner in detection and evaluation of temporal and spatial contrast enhancement of intracranial high density lesions. A multi-plane dynamic subtraction CT (MPDS-CT) was performed in 21 patients with intracranial high density lesions. These lesions consisted of 10 brain tumors, 7 intracerebral hemorrhages and 4 vascular malformations (2 untreated, 2 post-embolization). Baseline study was first performed, and 5 sequential planes of covering total high density lesions were selected. After obtaining the 5 sequential CT images as mask images, three series of multi-plane dynamic CT were performed for the same 5 planes with an intravenous bolus injection of contrast medium. MPDS-CT images were reconstructed by subtracting dynamic CT images from the mask ones. MPDS-CT were compared with conventional contrast-enhanced CT. MPDS-CT images showed the definite contrast enhancement of high density brain tumors and vascular malformations which were not clearly identified on conventional contrast-enhanced CT images because of calcified or hemorrhagic lesions and embolic materials, enabling us to eliminate enhanced abnormalities with non-enhanced areas such as unusual intracerebral hemorrhages. MPDS-CT will provide us further accurate and objective information and will be greatly helpful for interpreting pathophysiologic condition. (author).

  16. An audit of imaging test utilization for the management of lymphoma in an oncology hospital: implications for resource planning?

    Science.gov (United States)

    Schwartz, A; Gospodarowicz, M K; Khalili, K; Pintilie, M; Goddard, S; Keller, A; Tsang, R W

    2006-02-01

    The purpose of this study was to assist with resource planning by examining the pattern of physician utilization of imaging procedures for lymphoma patients in a dedicated oncology hospital. The proportion of imaging tests ordered for routine follow up with no specific clinical indication was quantified, with specific attention to CT scans. A 3-month audit was performed. The reasons for ordering all imaging procedures (X-rays, CT scans, ultrasound, nuclear scan and MRI) were determined through a retrospective chart review. 411 lymphoma patients had 686 assessments (sets of imaging tests) and 981 procedures (individual imaging tests). Most procedures were CT scans (52%) and chest radiographs (30%). The most common reasons for ordering imaging were assessing response (23%), and investigating new symptoms (19%). Routine follow up constituted 21% of the assessments (142/686), and of these, 82% were chest radiographs (116/142), while 24% (34/142) were CT scans. With analysis restricted to CT scans (296 assessments in 248 patients), the most common reason for ordering CT scans were response evaluation (40%), and suspicion of recurrence and/or new symptom (23%). Follow-up CT scans done with no clinical indication comprised 8% (25/296) of all CT assessments. Staging CT scans were under-represented at 6% of all assessments. Imaging with CT scans for follow up of asymptomatic patients is infrequent. However, scans done for staging new lymphoma patients were unexpectedly low in frequency, due to scans done elsewhere prior to referral. This analysis uncovered utilization patterns, helped resource planning and provided data to reduce unnecessary imaging procedures.

  17. Structural and Biochemical Characterization of Chlamydia trachomatis Hypothetical Protein CT263 Supports That Menaquinone Synthesis Occurs through the Futalosine Pathway*

    Science.gov (United States)

    Barta, Michael L.; Thomas, Keisha; Yuan, Hongling; Lovell, Scott; Battaile, Kevin P.; Schramm, Vern L.; Hefty, P. Scott

    2014-01-01

    The obligate intracellular human pathogen Chlamydia trachomatis is the etiological agent of blinding trachoma and sexually transmitted disease. Genomic sequencing of Chlamydia indicated this medically important bacterium was not exclusively dependent on the host cell for energy. In order for the electron transport chain to function, electron shuttling between membrane-embedded complexes requires lipid-soluble quinones (e.g. menaquionone or ubiquinone). The sources or biosynthetic pathways required to obtain these electron carriers within C. trachomatis are poorly understood. The 1.58Å crystal structure of C. trachomatis hypothetical protein CT263 presented here supports a role in quinone biosynthesis. Although CT263 lacks sequence-based functional annotation, the crystal structure of CT263 displays striking structural similarity to 5′-methylthioadenosine nucleosidase (MTAN) enzymes. Although CT263 lacks the active site-associated dimer interface found in prototypical MTANs, co-crystal structures with product (adenine) or substrate (5′-methylthioadenosine) indicate that the canonical active site residues are conserved. Enzymatic characterization of CT263 indicates that the futalosine pathway intermediate 6-amino-6-deoxyfutalosine (kcat/Km = 1.8 × 103 m−1 s−1), but not the prototypical MTAN substrates (e.g. S-adenosylhomocysteine and 5′-methylthioadenosine), is hydrolyzed. Bioinformatic analyses of the chlamydial proteome also support the futalosine pathway toward the synthesis of menaquinone in Chlamydiaceae. This report provides the first experimental support for quinone synthesis in Chlamydia. Menaquinone synthesis provides another target for agents to combat C. trachomatis infection. PMID:25253688

  18. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  19. Radiation exposure during CT-guided biopsies: recent CT machines provide markedly lower doses.

    Science.gov (United States)

    Guberina, Nika; Forsting, Michael; Ringelstein, Adrian; Suntharalingam, Saravanabavaan; Nassenstein, Kai; Theysohn, Jens; Wetter, Axel

    2018-03-28

    To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose index vol (CTDI vol ); dose-length product (DLP body ); size-specific dose estimate (SSDE)] were also compared. Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.

  20. Diagnosis of tracheal instability: inspiratory and expiratory spiral CT and cine CT

    International Nuclear Information System (INIS)

    Heussel, C.P.; Thelen, M.; Kauczor, H.U.; Hafner, B.; Lill, J.

    2000-01-01

    Purpose: In tracheo- and bronchomalacia, localization and determination of collapse is necessary for planning a surgical procedure. We compared inspiratory and spiral CT, cine CT, and bronchoscopy and evaluated the relevance of each method. Methods: Seventeen patients with suspected or verified tracheal stonosis or collapse underwent paired inspiratory and exspiratory spiral CT and cine CT during continuous respiration (temporal increment 100 ms). The tracheal cross-sectional area was calculated and compared. Results: In addition to bronchoscopy, further information concerning localization, extent, collapse, stability of the tracheal wall, distal portions of the stenosis, and extraluminal compressions was obtained. A significantly higher degree of tracheal collapse was seen using cine CT compared to paired spiral CT (p [de

  1. Implications of CT noise and artifacts for quantitative 99mTc SPECT/CT imaging

    International Nuclear Information System (INIS)

    Hulme, K. W.; Kappadath, S. C.

    2014-01-01

    Purpose: This paper evaluates the effects of computed tomography (CT) image noise and artifacts on quantitative single-photon emission computed-tomography (SPECT) imaging, with the aim of establishing an appropriate range of CT acquisition parameters for low-dose protocols with respect to accurate SPECT attenuation correction (AC). Methods: SPECT images of two geometric and one anthropomorphic phantom were reconstructed iteratively using CT scans acquired at a range of dose levels (CTDI vol = 0.4 to 46 mGy). Resultant SPECT image quality was evaluated by comparing mean signal, background noise, and artifacts to SPECT images reconstructed using the highest dose CT for AC. Noise injection was performed on linear-attenuation (μ) maps to determine the CT noise threshold for accurate AC. Results: High levels of CT noise (σ ∼ 200–400 HU) resulted in low μ-maps noise (σ ∼ 1%–3%). Noise levels greater than ∼10% in 140 keV μ-maps were required to produce visibly perceptible increases of ∼15% in 99m Tc SPECT images. These noise levels would be achieved at low CT dose levels (CTDI vol = 4 μGy) that are over 2 orders of magnitude lower than the minimum dose for diagnostic CT scanners. CT noise could also lower (bias) the expected μ values. The relative error in reconstructed SPECT signal trended linearly with the relative shift in μ. SPECT signal was, on average, underestimated in regions corresponding with beam-hardening artifacts in CT images. Any process that has the potential to change the CT number of a region by ∼100 HU (e.g., misregistration between CT images and SPECT images due to motion, the presence of contrast in CT images) could introduce errors in μ 140 keV on the order of 10%, that in turn, could introduce errors on the order of ∼10% into the reconstructed 99m Tc SPECT image. Conclusions: The impact of CT noise on SPECT noise was demonstrated to be negligible for clinically achievable CT parameters. Because CT dose levels that affect

  2. Performance evaluation of the General Electric eXplore CT 120 micro-CT using the vmCT phantom

    Energy Technology Data Exchange (ETDEWEB)

    Bahri, M.A., E-mail: M.Bahri@ulg.ac.be [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Warnock, G.; Plenevaux, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Choquet, P.; Constantinesco, A. [Biophysique et Medecine Nucleaire, Hopitaux universitaires de Strasbourg, Strasbourg (France); Salmon, E.; Luxen, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); Seret, A. [ULg-Liege University, Cyclotron Research Centre, Liege, Bat. 30, Allee du 6 aout, 8 (Belgium); ULg-Liege University, Experimental Medical Imaging, Liege (Belgium)

    2011-08-21

    The eXplore CT 120 is the latest generation micro-CT from General Electric. It is equipped with a high-power tube and a flat-panel detector. It allows high resolution and high contrast fast CT scanning of small animals. The aim of this study was to compare the performance of the eXplore CT 120 with that of the eXplore Ultra, its predecessor for which the methodology using the vmCT phantom has already been described . The phantom was imaged using typical a rat (fast scan or F) or mouse (in vivo bone scan or H) scanning protocols. With the slanted edge method, a 10% modulation transfer function (MTF) was observed at 4.4 (F) and 3.9-4.4 (H) mm{sup -1} corresponding to 114 {mu}m resolution. A fairly larger MTF was obtained by the coil method with the MTF for the thinnest coil (3.3 mm{sup -1}) equal to 0.32 (F) and 0.34 (H). The geometric accuracy was better than 0.3%. There was a highly linear (R{sup 2}>0.999) relationship between measured and expected CT numbers for both the CT number accuracy and linearity sections of the phantom. A cupping effect was clearly seen on the uniform slices and the uniformity-to-noise ratio ranged from 0.52 (F) to 0.89 (H). The air CT number depended on the amount of polycarbonate surrounding the area where it was measured; a difference as high as approximately 200 HU was observed. This hindered the calibration of this scanner in HU. This is likely due to the absence of corrections for beam hardening and scatter in the reconstruction software. However in view of the high linearity of the system, the implementation of these corrections would allow a good quality calibration of the scanner in HU. In conclusion, the eXplore CT 120 achieved a better spatial resolution than the eXplore Ultra (based on previously reported specifications) and future software developments will include beam hardening and scatter corrections that will make the new generation CT scanner even more promising.

  3. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  4. Preoperative 4D CT Localization of Nonlocalizing Parathyroid Adenomas by Ultrasound and SPECT-CT.

    Science.gov (United States)

    Hinson, Andrew M; Lee, David R; Hobbs, Bradley A; Fitzgerald, Ryan T; Bodenner, Donald L; Stack, Brendan C

    2015-11-01

    To evaluate 4-dimensional (4D) computed tomography (CT) for the localization of parathyroid adenomas previously considered nonlocalizing on ultrasound and single-photon emission CT with CT scanning (SPECT-CT). To measure radiation exposure associated with 4D-CT and compared it with SPECT-CT. Case series with chart review. University tertiary hospital. Nineteen adults with primary hyperparathyroidism who underwent preoperative 4D CT from November 2013 through July 2014 after nonlocalizing preoperative ultrasound and technetium-99m SPECT-CT scans. Sensitivity, specificity, predictive values, and accuracy of 4D CT were evaluated. Nineteen patients (16 women and 3 men) were included with a mean age of 66 years (range, 39-80 years). Mean preoperative parathyroid hormone level was 108.5 pg/mL (range, 59.3-220.9 pg/mL), and mean weight of the excised gland was 350 mg (range, 83-797 mg). 4D CT sensitivity and specificity for localization to the patient's correct side of the neck were 84.2% and 81.8%, respectively; accuracy was 82.9%. The sensitivity for localizing adenomas to the correct quadrant was 76.5% and 91.5%, respectively; accuracy was 88.2%. 4D CT radiation exposure was significantly less than the radiation associated with SPECT-CT (13.8 vs 18.4 mSv, P = 0.04). 4D CT localizes parathyroid adenomas with relatively high sensitivity and specificity and allows for the localization of some adenomas not observed on other sestamibi-based scans. 4D CT was also associated with less radiation exposure when compared with SPECT-CT based on our study protocol. 4D CT may be considered as first- or second-line imaging for localizing parathyroid adenomas in the setting of primary hyperparathyroidism. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  5. Electronic cleansing for 24-h limited bowel preparation CT colonography using principal curvature flow

    NARCIS (Netherlands)

    van Ravesteijn, Vincent F.; Boellaard, Thierry N.; van der Paardt, Marije P.; Serlie, Iwo W. O.; de Haan, Margriet C.; Stoker, Jaap; van Vliet, Lucas J.; Vos, Frans M.

    2013-01-01

    CT colonography (CTC) is one of the recommended methods for colorectal cancer screening. The subject's preparation is one of the most burdensome aspects of CTC with a cathartic bowel preparation. Tagging of the bowel content with an oral contrast medium facilitates CTC with limited bowel

  6. Initial implementation of the conversion from the energy-subtracted CT number to electron density in tissue inhomogeneity corrections: An anthropomorphic phantom study of radiotherapy treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Tsukihara, Masayoshi [Division of Radiological Technology, Graduate School of Health Sciences, Niigata University, Niigata 951-8518 (Japan); Noto, Yoshiyuki [Department of Radiology, Niigata University Medical and Dental Hospital, Niigata 951-8520 (Japan); Sasamoto, Ryuta; Hayakawa, Takahide; Saito, Masatoshi, E-mail: masaito@clg.niigata-u.ac.jp [Department of Radiological Technology, School of Health Sciences, Faculty of Medicine, Niigata University, Niigata 951-8518 (Japan)

    2015-03-15

    Purpose: To achieve accurate tissue inhomogeneity corrections in radiotherapy treatment planning, the authors had previously proposed a novel conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide range of ρ{sub e}. The purpose of this study is to present an initial implementation of the ΔHU–ρ{sub e} conversion method for a treatment planning system (TPS). In this paper, two example radiotherapy plans are used to evaluate the reliability of dose calculations in the ΔHU–ρ{sub e} conversion method. Methods: CT images were acquired using a clinical dual-source CT (DSCT) scanner operated in the dual-energy mode with two tube potential pairs and an additional tin (Sn) filter for the high-kV tube (80–140 kV/Sn and 100–140 kV/Sn). Single-energy CT using the same DSCT scanner was also performed at 120 kV to compare the ΔHU–ρ{sub e} conversion method with a conventional conversion from a CT number to ρ{sub e} (Hounsfield units, HU–ρ{sub e} conversion). Lookup tables for ρ{sub e} calibration were obtained from the CT image acquisitions for tissue substitutes in an electron density phantom (EDP). To investigate the beam-hardening effect on dosimetric uncertainties, two EDPs with different sizes (a body EDP and a head EDP) were used for the ρ{sub e} calibration. Each acquired lookup table was applied to two radiotherapy plans designed using the XiO TPS with the superposition algorithm for an anthropomorphic phantom. The first radiotherapy plan was for an oral cavity tumor and the second was for a lung tumor. Results: In both treatment plans, the performance of the ΔHU–ρ{sub e} conversion was superior to that of the conventional HU–ρ{sub e} conversion in terms of the reliability of dose calculations. Especially, for the oral tumor plan, which dealt with dentition and bony structures, treatment

  7. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  8. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  9. Shaping the Electronic Library--The UW-Madison Approach.

    Science.gov (United States)

    Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David

    1998-01-01

    This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…

  10. Filtered backprojection proton CT reconstruction along most likely paths

    Energy Technology Data Exchange (ETDEWEB)

    Rit, Simon; Dedes, George; Freud, Nicolas; Sarrut, David; Letang, Jean Michel [Universite de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Universite Lyon 1, Centre Leon Berard, 69008 Lyon (France)

    2013-03-15

    Purpose: Proton CT (pCT) has the potential to accurately measure the electron density map of tissues at low doses but the spatial resolution is prohibitive if the curved paths of protons in matter is not accounted for. The authors propose to account for an estimate of the most likely path of protons in a filtered backprojection (FBP) reconstruction algorithm. Methods: The energy loss of protons is first binned in several proton radiographs at different distances to the proton source to exploit the depth-dependency of the estimate of the most likely path. This process is named the distance-driven binning. A voxel-specific backprojection is then used to select the adequate radiograph in the distance-driven binning in order to propagate in the pCT image the best achievable spatial resolution in proton radiographs. The improvement in spatial resolution is demonstrated using Monte Carlo simulations of resolution phantoms. Results: The spatial resolution in the distance-driven binning depended on the distance of the objects from the source and was optimal in the binned radiograph corresponding to that distance. The spatial resolution in the reconstructed pCT images decreased with the depth in the scanned object but it was always better than previous FBP algorithms assuming straight line paths. In a water cylinder with 20 cm diameter, the observed range of spatial resolutions was 0.7 - 1.6 mm compared to 1.0 - 2.4 mm at best with a straight line path assumption. The improvement was strongly enhanced in shorter 200 Degree-Sign scans. Conclusions: Improved spatial resolution was obtained in pCT images with filtered backprojection reconstruction using most likely path estimates of protons. The improvement in spatial resolution combined with the practicality of FBP algorithms compared to iterative reconstruction algorithms makes this new algorithm a candidate of choice for clinical pCT.

  11. Indications for chest CT. Retrospective study of cases with normal chest CT

    International Nuclear Information System (INIS)

    Obata, Shiro

    1995-01-01

    The usefulness of computed tomography (CT) in thoracic radiology is now well appreciated, and the number of chest CTs has greatly increased. There are, however, many chest CT cases that are completely or almost completely normal. Indications for chest CT should be re-evaluated considering the cost and radiation exposure associated with the examination. Reviewing the reports of 4930 chest CT examinations performed in three hospitals during the period of two years, the author found 620 (12.6%) negative CT examinations. In 312 of the 620, the CT was requested because of 'abnormal shadow' on chest radiograph. When the same chest radiographs were re-evaluated by two radiologists, no abnormality was noted in 257 cases (82.4%). CT examinations were considered justified in only 55 cases (17.6%). There was a significant difference in the frequency of normal chest CT examinations between the university hospital and two other hospitals. The causes of false positive interpretation of chest radiographs were analyzed, and it was felt that fundamental knowledge necessary to interpret chest radiographs was lacking. The importance of close cooperation between clinicians and radiologists should be emphasized. (author)

  12. Micro-CT and nano-CT analysis of filling quality of three different endodontic sealers.

    Science.gov (United States)

    Huang, Yan; Celikten, Berkan; de Faria Vasconcelos, Karla; Ferreira Pinheiro Nicolielo, Laura; Lippiatt, Nicholas; Buyuksungur, Arda; Jacobs, Reinhilde; Orhan, Kaan

    2017-12-01

    To investigate voids in different root canal sealers using micro-CT and nano-CT, and to explore the feasibility of using nano-CT for quantitative analysis of sealer filling quality. 30 extracted mandibular central incisors were randomly assigned into three groups according to the applied root canal sealers (Total BC Sealer, Sure Seal Root, AH Plus) by the single cone technique. Subsequently, micro-CT and nano-CT were performed to analyse the incidence rate of voids, void fraction, void volume and their distribution in each sample. Micro-CT evaluation showed no significant difference among sealers for the incidence rate of voids or void fraction in the whole filling materials (p > 0.05), whereas a significant difference was found between AH Plus and the other two sealers using nano-CT (p nano-CT results displayed higher void volume in AH Plus among all the sealers and regions (p nano-CT analysis, when round root canals were treated by the single cone technique. The disparate results suggest that the higher resolution of nano-CT have a greater ability of distinguishing internal porosity, and therefore suggesting the potential use of nano-CT in quantitative analysis of filling quality of sealers.

  13. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  14. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  15. Non-enhanced CT versus contrast-enhanced CT in integrated PET/CT studies for nodal staging of rectal cancer

    International Nuclear Information System (INIS)

    Tateishi, Ukihide; Maeda, Tetsuo; Morimoto, Tsuyoshi; Miyake, Mototaka; Arai, Yasuaki; Kim, E.E.

    2007-01-01

    The purpose of the present study was to determine the diagnostic accuracy of non-enhanced CT and contrast-enhanced CT in integrated PET/CT studies for preoperative nodal staging of rectal cancer. Retrospective analysis was performed in 53 patients with pathologically proven rectal cancer who had been referred for preoperative staging. All patients underwent integrated PET/CT consisting of non-enhanced and contrast-enhanced CT followed by whole-body fluorine-18-fluorodeoxyglucose ([ 18 F]FDG) PET. Both non-enhanced and contrast-enhanced PET/CT images were evaluated separately by two observers in consensus. The reference standard was histopathologic results. For nodal staging of rectal cancer, we compared diagnostic accuracy on a per-patient basis between the two modalities. Nodal staging was correctly determined with non-enhanced studies in 37 patients (70%) and with contrast-enhanced studies in 42 patients (79%). On a per-patient basis, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of regional lymph node staging were 85%, 68%, 83%, 72%, and 79%, respectively, with contrast-enhanced studies, and 85%, 42%, 73%, 62%, and 70%, respectively, with non-enhanced studies. The difference in the accuracy of nodal staging between the two modalities was not significant (p = 0.063). Compared with non-enhanced studies, contrast-enhanced studies determined more correctly the status of pararectal lymph nodes (p 0.002), internal iliac lymph nodes (p = 0.004), and obturator lymph nodes (p < 0.0001). Contrast-enhanced PET/CT is superior to non-enhanced PET/CT for precise definition of regional nodal status in rectal cancer. (orig.)

  16. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  17. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Science.gov (United States)

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  18. Whole-body CT. Spiral and multislice CT. 2. tot. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Prokop, M.; Galanski, M.; Schaefer-Prokop, C.; Molen, A.J. van der

    2007-01-01

    Spiral and multidetector techniques have improved the diagnostic possibilities of CT, so that image analysis and interpretation have become increasingly complex. This book represents the current state of the art in CT imaging, including the most recent technical scanner developments. The second edition comprises the current state of knowledge in cT imaging. There are new chapters on image processing, application of contrasting agents and radiation dose. All organ-specific pathological findings are discussed in full. There are hints for optimum use and interpretation of CT, including CT angiography, CT colonography, CT-IVPL, and 3D imaging. There is an introduction to cardio-CT, from calcium scoring and CTA of the coronary arteries to judgement of cardiac morphology. There are detailed scan protocols with descriptions of how to go about parameter selection. Practical hints are given for better image quality and lower radiation exposure of patients, guidelines for patient preparation and complication management, and more than 1900 images in optimum RRR quality. (orig.)

  19. Scatter correction, intermediate view estimation and dose characterization in megavoltage cone-beam CT imaging

    Science.gov (United States)

    Sramek, Benjamin Koerner

    The ability to deliver conformal dose distributions in radiation therapy through intensity modulation and the potential for tumor dose escalation to improve treatment outcome has necessitated an increase in localization accuracy of inter- and intra-fractional patient geometry. Megavoltage cone-beam CT imaging using the treatment beam and onboard electronic portal imaging device is one option currently being studied for implementation in image-guided radiation therapy. However, routine clinical use is predicated upon continued improvements in image quality and patient dose delivered during acquisition. The formal statement of hypothesis for this investigation was that the conformity of planned to delivered dose distributions in image-guided radiation therapy could be further enhanced through the application of kilovoltage scatter correction and intermediate view estimation techniques to megavoltage cone-beam CT imaging, and that normalized dose measurements could be acquired and inter-compared between multiple imaging geometries. The specific aims of this investigation were to: (1) incorporate the Feldkamp, Davis and Kress filtered backprojection algorithm into a program to reconstruct a voxelized linear attenuation coefficient dataset from a set of acquired megavoltage cone-beam CT projections, (2) characterize the effects on megavoltage cone-beam CT image quality resulting from the application of Intermediate View Interpolation and Intermediate View Reprojection techniques to limited-projection datasets, (3) incorporate the Scatter and Primary Estimation from Collimator Shadows (SPECS) algorithm into megavoltage cone-beam CT image reconstruction and determine the set of SPECS parameters which maximize image quality and quantitative accuracy, and (4) evaluate the normalized axial dose distributions received during megavoltage cone-beam CT image acquisition using radiochromic film and thermoluminescent dosimeter measurements in anthropomorphic pelvic and head and

  20. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Site Index A-Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses ... of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... Z Children's (Pediatric) CT (Computed Tomography) Pediatric computed tomography (CT) is a fast, painless exam that uses special ... the limitations of Children's CT? What is Children's CT? Computed tomography, more commonly known as a CT or CAT ...

  2. MCNPX simulation of proton dose distribution in homogeneous and CT phantoms

    International Nuclear Information System (INIS)

    Lee, C.C.; Lee, Y.J.; Tung, C.J.; Cheng, H.W.; Chao, T.C.

    2014-01-01

    A dose simulation system was constructed based on the MCNPX Monte Carlo package to simulate proton dose distribution in homogeneous and CT phantoms. Conversion from Hounsfield unit of a patient CT image set to material information necessary for Monte Carlo simulation is based on Schneider's approach. In order to validate this simulation system, inter-comparison of depth dose distributions among those obtained from the MCNPX, GEANT4 and FLUKA codes for a 160 MeV monoenergetic proton beam incident normally on the surface of a homogeneous water phantom was performed. For dose validation within the CT phantom, direct comparison with measurement is infeasible. Instead, this study took the approach to indirectly compare the 50% ranges (R 50% ) along the central axis by our system to the NIST CSDA ranges for beams with 160 and 115 MeV energies. Comparison result within the homogeneous phantom shows good agreement. Differences of simulated R 50% among the three codes are less than 1 mm. For results within the CT phantom, the MCNPX simulated water equivalent R eq,50% are compatible with the CSDA water equivalent ranges from the NIST database with differences of 0.7 and 4.1 mm for 160 and 115 MeV beams, respectively. - Highlights: ► Proton dose simulation based on the MCNPX 2.6.0 in homogeneous and CT phantoms. ► CT number (HU) conversion to electron density based on Schneider's approach. ► Good agreement among MCNPX, GEANT4 and FLUKA codes in a homogeneous water phantom. ► Water equivalent R 50 in CT phantoms are compatible to those of NIST database

  3. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Directory of Open Access Journals (Sweden)

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  4. Upright 3D Treatment Planning Using a Vertical CT

    International Nuclear Information System (INIS)

    Shah, Anand P.; Strauss, Jonathan B.; Kirk, Michael C.; Chen, Sea S.; Kroc, Thomas K.; Zusag, Thomas W.

    2009-01-01

    In this report, we describe a novel technique used to plan and administer external beam radiation therapy to a patient in the upright position. A patient required reirradiation for thymic carcinoma but was unable to tolerate the supine position due to bilateral phrenic nerve injury and paralysis of the diaphragm. Computed tomography (CT) images in the upright position were acquired at the Northern Illinois University Institute for Neutron Therapy at Fermilab. The CT data were imported into a standard 3-dimensional (3D) treatment planning system. Treatment was designed to deliver 24 Gy to the target volume while respecting normal tissue tolerances. A custom chair that locked into the treatment table indexing system was constructed for immobilization, and port films verified the reproducibility of setup. Radiation was administered using mixed photon and electron AP fields

  5. Electronic resources access and usage among the postgraduates of ...

    African Journals Online (AJOL)

    ... and usage among the postgraduates of a Nigerian University of Technology. ... faced by postgraduates in using e-resources include takes too much time to find, ... Resources, Access, Use, Postgraduat, Students, University, Technology, Nigeria ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  6. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  7. The impact of FDG-PET/CT in the management of patients with vulvar and vaginal cancer.

    Science.gov (United States)

    Robertson, N L; Hricak, H; Sonoda, Y; Sosa, R E; Benz, M; Lyons, G; Abu-Rustum, N R; Sala, E; Vargas, H A

    2016-03-01

    To evaluate the changes in prognostic impression and patient management following PET/CT in patients with vulvar and vaginal carcinoma; and to compare PET/CT findings with those of conventional imaging modalities. We summarized prospectively and retrospectively collected data for 50 consecutive patients from our institution that enrolled in the National Oncologic PET Registry and underwent FDG-PET/CT for a suspected or known primary or recurrent vulvar/vaginal cancer. 54/83 (65%) studies included had a diagnosis of vulvar cancer, and the remaining 29/83 (35%), a diagnosis of vaginal cancer. Following FDG-PET/CT, the physician's prognostic impression changed in 51% of cases. A change in patient management, defined as a change to/from a non-interventional strategy (observation or additional imaging), to/from an interventional strategy (biopsy or treatment), was documented in 36% of studies. The electronic records demonstrated that 95% of the management strategies recorded in the physician questionnaires were implemented as planned. MRI and/or CT were performed within one month of the FDG-PET/CT in 20/83 (24%) and 28/83 (34%) cases, respectively. FDG-PET/CT detected nodes suspicious for metastases on 29/83 (35%) studies performed. MRI and CT detected positive nodes on 6 and 11 studies respectively. Distant metastases were identified in 10 cases imaged with FDG-PET and 5 cases that had additional conventional CT imaging. All suspicious lesions seen on CT were positively identified on PET/CT. In 4 cases, an abnormality identified on PET/CT, was not seen on diagnostic CT. FDG-PET/CT may play an important role in the management of vulvar and vaginal carcinoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Electronic cleansing for computed tomography (CT) colonography using a scale-invariant three-material model

    NARCIS (Netherlands)

    Serlie, Iwo W. O.; Vos, Frans M.; Truyen, Roel; Post, Frits H.; Stoker, Jaap; van Vliet, Lucas J.

    2010-01-01

    A well-known reading pitfall in computed tomography (CT) colonography is posed by artifacts at T-junctions, i.e., locations where air-fluid levels interface with the colon wall. This paper presents a scale-invariant method to determine material fractions in voxels near such T-junctions. The proposed

  9. Spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies

    International Nuclear Information System (INIS)

    Prokesch, R.; Bankier, A.; Ba-Ssalamah, A.; Imhof, H.; Lakits, A.; Scholda, C.

    1998-01-01

    Purpose: To compare the effectiveness of spiral CT versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies. Results: All foreign bodies were detected by each scanning modality on the axial and on the reconstructed planes. The quality of the axial images was similar for spiral and conventional CT. The spiral technique provided high-quality reconstructed images which allowed accurate localization of the foreign bodies in all cases. Reconstructions by conventional technique were inadequate for preoperative assessment. The examination time for the total orbital volume was 18 s for spiral CT and 52 s for conventional CT. Radiation dose delivered to the lens was 35 mGy for spiral CT and 56 mGy for conventional CT axial scanning. Conclusion: Spiral CT multiplanar offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, minimized motion artifacts, reduced radiation exposure, and accurate localization. (orig.) [de

  10. The evaluation of complex clinical trial protocols: resources available to research ethics committees and the use of clinical trial registries--a case study.

    Science.gov (United States)

    Homedes, Núria; Ugalde, Antonio

    2015-06-01

    To assess the potential role of clinical trial (CT) registries and other resources available to research ethics committees (RECs) in the evaluation of complex CT protocols in low-income and middle-income countries. Using a case study approach, the authors examined the decision-making process of a REC in Argentina and its efforts to use available resources to decide on a complex protocol. We also analysed the information in the USA and other CT registries and consulted 24 CT experts in seven countries. Information requested by the Argentinean REC from other national RECs and ethics' experts was not useful to verify the adequacy of the REC's decision whether or not to approve the CT. The responses from the national regulatory agency and the sponsor were not helpful either. The identification of international resources that could assist was beyond the REC's capability. The information in the USA and other CT registries is limited, and at times misleading; and its accuracy is not verified by register keepers. RECs have limited access to experts and institutions that could assist them in their deliberations. Sponsors do not always answer RECs' request for information to properly conduct the ethical and methodological assessment of CT protocols. The usefulness of the CT registries is curtailed by the lack of appropriate codes and by data errors. Information about reasons for rejection, withdrawal or suspension of the trial should be included in the registries. Establishing formal channels of communication among national and foreign RECs and with independent international reference centres could strengthen the ethical review of CT protocols. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. MRI-based treatment planning with pseudo CT generated through atlas registration.

    Science.gov (United States)

    Uh, Jinsoo; Merchant, Thomas E; Li, Yimei; Li, Xingyu; Hua, Chiaho

    2014-05-01

    To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration. A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference. The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787-0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%-98.7%) satisfied the criteria of chi-evaluation (pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs

  12. Evaluation of shielding capability of controlled area for CT examination room

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nakai, Takayo; Takeuchi, Kichito; Kinoshita, Kazuo; Watanabe, Nobuyuki; Koga, Sukehiko

    2002-01-01

    With the revision of the law in April, 2001, the effective dose at the boundary of the controlled area was set at 1.3 mSv/3M. Whether the shielding capability of the CT room satisfied the provisions of the law or not was confirmed by actual measurements. Both thermo luminescence dosemeter (TLD) and electronic dosemeter were used to measure the radiation doses. The shielding capability of the gantry was studied both inside and outside the room for a week as a basic experiment. On the basis of the data thus obtained doses accumulated in 3 months were estimated. According to the results of 3 month-measurement, the doses outside the wall of the CT room were about 200μ Sv. This numerical value was comparable to the background level of the evaluation point. The results above assured that the shielding capability of the CT room satisfied the provisions of the law well. (author)

  13. A patch-based pseudo-CT approach for MRI-only radiotherapy in the pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Andreasen, Daniel, E-mail: dana@dtu.dk [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark); Van Leemput, Koen [Department of Applied Mathematics and Computer Science, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark and A.A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts 02129 (United States); Edmund, Jens M. [Radiotherapy Research Unit, Department of Oncology, Gentofte and Herlev Hospital, University of Copenhagen, 2730 Herlev (Denmark)

    2016-08-15

    Purpose: In radiotherapy based only on magnetic resonance imaging (MRI), knowledge about tissue electron densities must be derived from the MRI. This can be achieved by converting the MRI scan to the so-called pseudo-computed tomography (pCT). An obstacle is that the voxel intensities in conventional MRI scans are not uniquely related to electron density. The authors previously demonstrated that a patch-based method could produce accurate pCTs of the brain using conventional T{sub 1}-weighted MRI scans. The method was driven mainly by local patch similarities and relied on simple affine registrations between an atlas database of the co-registered MRI/CT scan pairs and the MRI scan to be converted. In this study, the authors investigate the applicability of the patch-based approach in the pelvis. This region is challenging for a method based on local similarities due to the greater inter-patient variation. The authors benchmark the method against a baseline pCT strategy where all voxels inside the body contour are assigned a water-equivalent bulk density. Furthermore, the authors implement a parallelized approximate patch search strategy to speed up the pCT generation time to a more clinically relevant level. Methods: The data consisted of CT and T{sub 1}-weighted MRI scans of 10 prostate patients. pCTs were generated using an approximate patch search algorithm in a leave-one-out fashion and compared with the CT using frequently described metrics such as the voxel-wise mean absolute error (MAE{sub vox}) and the deviation in water-equivalent path lengths. Furthermore, the dosimetric accuracy was tested for a volumetric modulated arc therapy plan using dose–volume histogram (DVH) point deviations and γ-index analysis. Results: The patch-based approach had an average MAE{sub vox} of 54 HU; median deviations of less than 0.4% in relevant DVH points and a γ-index pass rate of 0.97 using a 1%/1 mm criterion. The patch-based approach showed a significantly better

  14. Electron absorbed fractions in skeletal soft tissues based on red bone marrow segmentation at runtime in muCT images of human trabecular bone;Fracoes absorvidas de eletrons em tecidos moles do esqueleto avaliadas com base na segmentacao em tempo de execucao da medula ossea vermelha contida em imagens muCT do osso trabecular humano

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, J.W. [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco, Recife, PE (Brazil); Kramer, R. [Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica; Khoury, H.J. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Robson-Brown, K. [University of Bristol, Bristol (United Kingdom). Dept. of Archaeology and Anthropology

    2009-07-01

    Skeletal dosimetry determines equivalent dose or absorbed fractions in the red bone marrow (RBM) and the osteogenic cells on bone surfaces (BSC). Following a method used earlier for the BSC, RBM and yellow bone marrow (YBM) have been segmented in the marrow cavities of muCT images of human spongiosa at runtime, i.e. during the execution of the Monte Carlo calculation, which avoids the necessity to segment RBM and YBM externally in muCT images for many different cellularities and to store the data. Using this internal RBM/YBM segmentation, this study presents electron absorbed fractions for the RBM and the BSC as a function of the voxel resolution and also compares the results with data from other investigations. (author)

  15. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  16. Design and Development of a Megavoltage CT Scanner for Radiation Therapy.

    Science.gov (United States)

    Chen, Ching-Tai

    A Varian 4 MeV isocentric therapy accelerator has been modified to perform also as a CT scanner. The goal is to provide low cost computed tomography capability for use in radiotherapy. The system will have three principal uses. These are (i) to provide 2- and 3-dimensional maps of electron density distribution for CT assisted therapy planning, (ii) to aid in patient set up by providing sectional views of the treatment volume and high contrast scout-mode verification images and (iii) to provide a means for periodically checking the patients anatomical conformation against what was used to generate the original therapy plan. The treatment machine was modified by mounting an array of detectors on a frame bolted to the counter weight end of the gantry in such a manner as to define a 'third generation' CT Scanner geometry. The data gathering is controlled by a Z-80 based microcomputer system which transfers the x-ray transmission data to a general purpose PDP 11/34 for processing. There a series of calibration processes and a logarithmic conversion are performed to get projection data. After reordering the projection data to an equivalent parallel beam sinogram format a convolution algorithm is employed to construct the image from the equivalent parallel projection data. Results of phantom studies have shown a spatial resolution of 2.6 mm and an electron density discrimination of less than 1% which are sufficiently good for accurate therapy planning. Results also show that the system is linear to within the precision of our measurement ((DBLTURN).75%) over a wide range of electron densities corresponding to those found in body tissues. Animal and human images are also presented to demonstrate that the system's imaging capability is sufficient to allow the necessary visualization of anatomy.

  17. Validation of a large-scale audit technique for CT dose optimisation

    International Nuclear Information System (INIS)

    Wood, T. J.; Davis, A. W.; Moore, C. S.; Beavis, A. W.; Saunderson, J. R.

    2008-01-01

    The expansion and increasing availability of computed tomography (CT) imaging means that there is a greater need for the development of efficient optimisation strategies that are able to inform clinical practice, without placing a significant burden on limited departmental resources. One of the most fundamental aspects to any optimisation programme is the collection of patient dose information, which can be compared with appropriate diagnostic reference levels. This study has investigated the implementation of a large-scale audit technique, which utilises data that already exist in the radiology information system, to determine typical doses for a range of examinations on four CT scanners. This method has been validated against what is considered the 'gold standard' technique for patient dose audits, and it has been demonstrated that results equivalent to the 'standard-sized patient' can be inferred from this much larger data set. This is particularly valuable where CT optimisation is concerned as it is considered a 'high dose' technique, and hence close monitoring of patient dose is particularly important. (authors)

  18. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  19. Improved attenuation correction for respiratory gated PET/CT with extended-duration cine CT: a simulation study

    Science.gov (United States)

    Zhang, Ruoqiao; Alessio, Adam M.; Pierce, Larry A.; Byrd, Darrin W.; Lee, Tzu-Cheng; De Man, Bruno; Kinahan, Paul E.

    2017-03-01

    Due to the wide variability of intra-patient respiratory motion patterns, traditional short-duration cine CT used in respiratory gated PET/CT may be insufficient to match the PET scan data, resulting in suboptimal attenuation correction that eventually compromises the PET quantitative accuracy. Thus, extending the duration of cine CT can be beneficial to address this data mismatch issue. In this work, we propose to use a long-duration cine CT for respiratory gated PET/CT, whose cine acquisition time is ten times longer than a traditional short-duration cine CT. We compare the proposed long-duration cine CT with the traditional short-duration cine CT through numerous phantom simulations with 11 respiratory traces measured during patient PET/CT scans. Experimental results show that, the long-duration cine CT reduces the motion mismatch between PET and CT by 41% and improves the overall reconstruction accuracy by 42% on average, as compared to the traditional short-duration cine CT. The long-duration cine CT also reduces artifacts in PET images caused by misalignment and mismatch between adjacent slices in phase-gated CT images. The improvement in motion matching between PET and CT by extending the cine duration depends on the patient, with potentially greater benefits for patients with irregular breathing patterns or larger diaphragm movements.

  20. EFFECTIVE ELECTRONIC TUTORIAL

    Directory of Open Access Journals (Sweden)

    Andrei A. Fedoseev

    2014-01-01

    Full Text Available The article analyzes effective electronic tutorials creation and application based on the theory of pedagogy. Herewith the issues of necessary electronic tutorial functional, ways of the educational process organization with the use of information and communication technologies and the logistics of electronic educational resources are touched upon. 

  1. The feasibility of utilizing pseudo CT-data for online MRI based treatment plan adaptation for a stereotactic radiotherapy treatment of spinal bone metastases

    International Nuclear Information System (INIS)

    Hoogcarspel, Stan J; Van der Velden, Joanne M; Lagendijk, Jan J W; Van Vulpen, Marco; Raaymakers, Bas W

    2014-01-01

    The purpose of this study was to investigate what pseudo-CT (pCT) strategy is sufficient for online MRI based treatment plan adaptation of a stereotactic treatment for spinal bone metastases. For this purpose, the dosimetric accuracy of five increasingly complex pCT strategies was evaluated using the planning CT data of 20 patients suffering from spinal metastases. For each pCT, a treatment plan was developed and simulated on both the pCT and the original CT data of the patient. The two resulting dose distributions were compared using gamma analysis of 2%/2 mm. In this paper, a Gamma Pass Rate (GPR) of ⩾95% within the Target Volume (TV) was considered clinically acceptable. We additionally demonstrated in this paper the automatic generation of each investigated pCT strategy with the use of dedicated MRI data complemented with pre-treatment CT data of a patient in treatment position. The dosimetric accuracy of a pCT increases when additional bulk densities are utilized for a pCT. However, the dosimetric accuracy of even the most complex ‘bulk density’ pCT strategy used in this study had an average GPR of only 78% within the TV. However, if information on the heterogeneous electron density distribution within the affected vertebral body was available, a clinically acceptable 99% mean GPR was observed. All pCTs could successfully be generated using the MRI data in combination with the CT data of a patient in treatment position. The results presented in this study show that a simple ‘bulk density’ pseudo-CT strategy is not feasible for online MRI based treatment plan adaptation for spinal bone metastases. However, a clinically acceptable result is generated if the information on the heterogeneous electron density (ED) distribution within the affected vertebral bone is available. Therefore, any pCT strategy for this tumor site should include a method which can estimate the heterogeneous ED of the affected vertebral bone. (paper)

  2. A modified VMAT adaptive radiotherapy for nasopharyngeal cancer patients based on CT-CT image fusion

    International Nuclear Information System (INIS)

    Jin, Xiance; Han, Ce; Zhou, Yongqiang; Yi, Jinling; Yan, Huawei; Xie, Congying

    2013-01-01

    To investigate the feasibility and benefits of a modified adaptive radiotherapy (ART) by replanning in the initial CT (iCT) with new contours from a repeat CT (rCT) based on CT-CT image fusion for nasopharyngeal cancer (NPC) patients underwent volumetric modulated arc radiotherapy (VMAT). Nine NPC patients underwent VMAT treatment with a rCT at 23rd fraction were enrolled in this study. Dosimetric differences for replanning VMAT plans in the iCT and in the rCT were compared. Volumetric and dosimetric changes of gross tumor volume (GTV) and organs at risk (OARs) of this modified ART were also investigated. No dosimetric differences between replanning in the iCT and in the rCT were observed. The average volume of GTV decreased from 78.83 ± 38.42 cm 3 in the iCT to 71.44 ± 37.46 cm 3 in the rCT, but with no significant difference (p = 0.42).The average volume of the left and right parotid decreased from 19.91 ± 4.89 cm 3 and 21.58 ± 6.16 cm 3 in the iCT to 11.80 ± 2.79 cm 3 and 13.29 ± 4.17 cm 3 in the rCT (both p < 0.01), respectively. The volume of other OARs did not shrink very much. No significant differences on PTV GTV and PTV CTV coverage were observed for replanning with this modified ART. Compared to the initial plans, the average mean dose of the left and right parotid after re-optimization were decreased by 62.5 cGy (p = 0.05) and 67.3 cGy (p = 0.02), respectively, and the V5 (the volume receiving 5 Gy) of the left and right parotids were decreased by 7.8% (p = 0.01) and 11.2% (p = 0.001), respectively. There was no significant difference on the dose delivered to other OARs. Patients with NPC undergoing VMAT have significant anatomic and dosimetric changes to parotids. Repeat CT as an anatomic changes reference and re-optimization in the iCT based on CT-CT image fusion was accurate enough to identify the volume changes and to ensure safe dose to parotids

  3. A Time-Based Front End Readout System for PET & CT

    CERN Document Server

    Meyer, T C; Anghinolfi, F; Auffray, E; Dosanjh, M; Hillemanns, H; Hoffmann, H -F; Jarron, P; Kaplon, J; Kronberger, M; Lecoq, P; Moraes, D; Trummer, J

    2007-01-01

    In the framework of the European FP6's BioCare project, we develop a novel, time-based, photo-detector readout technique to increase sensitivity and timing precision for molecular imaging in PET and CT. The project aims to employ Avalanche Photo Diode (APD) arrays with state of the art, high speed, front end amplifiers and discrimination circuits developed for the Large Hadron Collider (LHC) physics program at CERN, suitable to detect and process photons in a combined one-unit PET/CT detection head. In the so-called time-based approach our efforts focus on the system's timing performance with sub-nanosecond time-jitter and -walk, and yet also provide information on photon energy without resorting to analog to digital conversion. The bandwidth of the electronic circuitry is compatible with the scintillator's intrinsic light response (e.g. les40ns in LSO) and hence allows high rate CT operation in single-photon counting mode. Based on commercial LSO crystals and Hamamatsu S8550 APD arrays, we show the system pe...

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow nearly all CT scanners to obtain multiple slices in a single rotation. These scanners, called multislice CT or multidetector CT, ...

  7. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  8. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  9. Integrated three-dimensional display of MR, CT, and PET images of the brain

    International Nuclear Information System (INIS)

    Levin, D.N.; Herrmann, A.; Chen, G.T.Y.

    1988-01-01

    MR, CT, and PET studies depict complementary aspects of brain anatomy and function. The authors' own image-processing software and a Pixar image computer were used to create three-dimensional models of brain soft tissues from MR images, of the skull and calcifications from CT scans, and of brain metabolism from PET images. An image correlation program, based on surface fitting, was used for retrospective registration and merging of these three-dimensional models. The results are demonstrated in a video clip showing how the operator may rotate and perform electronic surgery on the integrated, multimodality three-dimensional model of each patient's brain

  10. Examination of jaws and teeth using Dental CT

    International Nuclear Information System (INIS)

    Nikolov, Vl.

    2001-01-01

    The aim of the present work was to establish a new method for dental imaging using Dental CT. Dental computer assisted tomography represents valuable addition to the diagnostics spectrum for planning oral and maxillofacial surgery. High resolution spiral CT and specially designed computer software allow representation of the jaws in different planes that are easy to match. The further allow the display of very small structures relevant to oral surgical interventions and reveal their spatial relationship in three dimensions. Dental CT is indicated, when clinical and conventional radiological techniques will not allow exact interpretation of the situation. It is modern oral implantology that primarily benefits from computer software enabling the assessment of surgical sites in the pre surgical phase. Such planning was not yet possible using two dimensional radiographic techniques. The dental-implantological part expects from radiography sharply defined contours of the external bony contours and the mandibular canal, exactly defined relation between slices and planes, no distortion in the ortho-radial planes, tools for reliable measurements of distances, angles and volumes, possibility to transmit pictures electronically or on hardcopy without loss of quality. Thus communication between dentists and radiologists may and must be intensified and supported by usage of modern telecommunication systems. (author)

  11. Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates

    Science.gov (United States)

    Farace, Paolo

    2014-11-01

    A two-steps procedure is presented to convert dual-energy CT data to stopping power ratio (SPR), relative to water. In the first step the relative electron density (RED) is calculated from dual-energy CT-numbers by means of a bi-linear relationship: RED = a HUscH + b HUscL + c, where HUscH and HUscL are scaled units (HUsc = HU + 1000) acquired at high and low energy respectively, and the three parameters a, b and c has to be determined for each CT scanner. In the second step the RED values were converted into SPR by means of published poly-line functions, which are invariant as they do not depend on a specific CT scanner. The comparison with other methods provides encouraging results, with residual SPR error on human tissue within 1%. The distinctive features of the proposed method are its simplicity and the generality of the conversion functions.

  12. Experimental verification of ion stopping power prediction from dual energy CT data in tissue surrogates.

    Science.gov (United States)

    Farace, Paolo

    2014-11-21

    A two-steps procedure is presented to convert dual-energy CT data to stopping power ratio (SPR), relative to water. In the first step the relative electron density (RED) is calculated from dual-energy CT-numbers by means of a bi-linear relationship: RED=a HUscH+b HUscL+c, where HUscH and HUscL are scaled units (HUsc=HU+1000) acquired at high and low energy respectively, and the three parameters a, b and c has to be determined for each CT scanner. In the second step the RED values were converted into SPR by means of published poly-line functions, which are invariant as they do not depend on a specific CT scanner. The comparison with other methods provides encouraging results, with residual SPR error on human tissue within 1%. The distinctive features of the proposed method are its simplicity and the generality of the conversion functions.

  13. Postoperative CT in pancreas transplantation

    International Nuclear Information System (INIS)

    Powell, F.E.; Harper, S.J.F.; Callaghan, C.J.; Shaw, A.; Godfrey, E.M.; Bradley, J.A.; Watson, C.J.E.; Pettigrew, G.J.

    2015-01-01

    Aim: To examine the usage and value of computed tomography (CT) following simultaneous pancreas and kidney (SPK) transplantation. Materials and methods: Indications for postoperative CT, key findings, and their influence on management were determined by retrospective analysis. Results: Ninety-eight patients underwent 313 CT examinations. Common indications for the examinations included suspected intra-abdominal collection (31.1%) and elevated serum amylase/lipase (24.1%). CT findings most frequently showed non-specific mild inflammation (27.6%), a normal scan (17.1%) and fluid collections (16.3%). High capillary blood glucose (CBG) was associated with resultant CT demonstration of graft vascular abnormalities, but otherwise, particular clinical indications were not associated with specific CT findings. Conclusion: Clinical findings in patients with SPK transplants are non-specific. The pattern of abnormalities encountered is significantly different to those seen in native pancreatic disease and demands a tailored protocol. CT enables accurate depiction of vascular abnormalities and fluid collections, thus reducing the number of surgical interventions that might otherwise be required. Elevated CBG should prompt urgent CT to exclude potentially reversible vascular complications. - Highlights: • The value of CT following simultaneous pancreas and kidney transplantation was assessed. • 313 CT scans were performed on 98 patients between January 2005 and August 2010. • Elevated blood glucose was associated with CT findings of graft vascular anomalities. • CT was particularly useful in directing operative versus non-operative intervention.

  14. Spinal CT scan, 2

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi

    1982-01-01

    Plain CT described fairly accurately the anatomy and lesions of the lumbar and sacral spines on their transverse sections. Since hernia of the intervertebral disc could be directly diagnosed by CT, indications of myelography could be restricted. Spinal-canal stenosis of the lumbar spine occurs because of various factors, and CT not only demonstrated the accurate size and morphology of bony canals, but also elucidated thickening of the joints and yellow ligament. CT was also useful for the diagnosis of tumors in the lumbar and sacral spines, visualizing the images of bone changes and soft tissues on the trasverse sections. But the diagnosis of intradural tumors required myelography and metrizamide CT. CT has become important for the diagnosis of spinal and spinal-cord diseases and for selection of the route of surgical arrival. (Chiba, N.)

  15. CT-Info: uma visão a fundo

    Directory of Open Access Journals (Sweden)

    Daniele Nogueira Milani

    2011-11-01

    Full Text Available O presente estudo adota uma metodologia diferenciada de avaliação dos fundos setoriais e tem por objetivo realizar uma dissecção da dinâmica de funcionamento e dos impactos do CT-Info à luz do que está estabelecido como seu foco, que é fomentar projetos em empresas brasileiras do setor de informática. Para tanto, foi realizada uma investigação que buscou responder a três questões fundamentais: qual o perfil das empresas que obtiveram recursos concedidos pelo CT-Info? Como se desenvolveu a dinâmica de utilização desses recursos? Qual a motivação para que empresas recorram ou não ao instrumento? Por um lado, os resultados apontam para uma captura do instrumento pelo complexo acadêmico-universitário. Por outro, para as poucas empresas beneficiárias, apesar das dificuldades burocráticas, os resultados obtidos foram muito expressivos.This articles adopts a differentiated methodology for evaluating sectoral funds, and its aim is to analyze the functioning and the impacts of CT-Info in what regards to its focus: to support projects in Brazilian information technology firms. To accomplish this goal, the research tried to answer three fundamental questions: what is the profile of the firms supported by CT-Info? How was the dynamics of utilization of the resources? What was the motivation for firms to use or not to use the instrument? In one hand, results point to a capture of the instrument by the Academy. On the other hand, for the few supported firms, despite bureaucratic difficulties, the obtained results were very important.

  16. CT manifestations of liver abscess

    International Nuclear Information System (INIS)

    Yan Jianfeng; Peng Yongjun

    2006-01-01

    Objective: To study CT findings of hepatic abscess. Methods: CT findings and clinical materials of 38 patients with liver abscess verified by aspiration were retrospectively viewed. All patients were examined by non-enhanced and contrast enhanced CT. Results: In 25 cases, inhomogeneous hypodense lesions with unclear demarcation were found on non-enhanced CT. On contrast enhanced CT scan, target or cluster enhancement was found Additionally, air was found within some lesions. In the rest 13 cases with early stage liver abscess, no typical sign was found on non-enhanced CT, while rosette sign and continued enhancement sign were demonstrated after the contrast agent was given. Conclusion: Various CT findings are found in different stages of liver abscess. The diagnosis and differential diagnosis should be based on CT manifestations and clinical history as well. (authors)

  17. Radiation exposure during paediatric CT in Sudan: CT dose, organ and effective doses

    International Nuclear Information System (INIS)

    Suliman, I.I.; Khamis, H.M.; Ombada, T.H.; Alzimami, K.; Alkhorayef, M.; Sulieman, A.

    2015-01-01

    The purpose of this study was to assess the magnitude of radiation exposure during paediatric CT in Sudanese hospitals. Doses were determined from CT acquisition parameters using CT-Expo 2.1 dosimetry software. Doses were evaluated for three patient ages (0-1, 1-5 and 5-10 y) and two common procedures (head and abdomen). For children aged 0-1 y, volume CT air kerma index (C vol ), air Kerma-length product and effective dose (E) values were 19.1 mGy, 265 mGy.cm and 3.1 mSv, respectively, at head CT and those at abdominal CT were 8.8 mGy, 242 mGy.cm and 7.7 mSv, respectively. Those for children aged 1-5 y were 22.5 mGy, 305 mGy.cm and 1.1 mSv, respectively, at head CT and 12.6 mGy, 317 mGy.cm, and 5.1 mSv, respectively, at abdominal CT. Dose values and variations were comparable with those reported in the literature. Organ equivalent doses vary from 7.5 to 11.6 mSv for testes, from 9.0 to 10.0 mSv for ovaries and from 11.1 to 14.3 mSv for uterus in abdominal CT. The results are useful for dose optimisation and derivation of national diagnostic reference levels. (authors)

  18. CT of the knee

    International Nuclear Information System (INIS)

    Ghelman, B.

    1987-01-01

    CT can be combined with arthrography of the knee to study the following abnormalities: meniscal tears and cysts, synovial plicae, chondromalacia patellae, and osteochondritis dissecans. The CT-arthrogram images present abnormalities in a manner that resembles the ''in situ'' surgical findings, allowing management decisions to be made with greater confidence. The CT techniques for imaging the knee after arthrography are discussed, as is the use of plain CT

  19. Renewable energy resources

    DEFF Research Database (Denmark)

    Ellabban, Omar S.; Abu-Rub, Haitham A.; Blaabjerg, Frede

    2014-01-01

    Electric energy security is essential, yet the high cost and limited sources of fossil fuels, in addition to the need to reduce greenhouse gasses emission, have made renewable resources attractive in world energy-based economies. The potential for renewable energy resources is enormous because...... they can, in principle, exponentially exceed the world's energy demand; therefore, these types of resources will have a significant share in the future global energy portfolio, much of which is now concentrating on advancing their pool of renewable energy resources. Accordingly, this paper presents how...... renewable energy resources are currently being used, scientific developments to improve their use, their future prospects, and their deployment. Additionally, the paper represents the impact of power electronics and smart grid technologies that can enable the proportionate share of renewable energy...

  20. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... are the limitations of CT of the Sinuses? What is CT (Computed Tomography) of the Sinuses? Computed ... nasal cavity by small openings. top of page What are some common uses of the procedure? CT ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  2. 3D imaging by serial block face scanning electron microscopy for materials science using ultramicrotomy.

    Science.gov (United States)

    Hashimoto, Teruo; Thompson, George E; Zhou, Xiaorong; Withers, Philip J

    2016-04-01

    Mechanical serial block face scanning electron microscopy (SBFSEM) has emerged as a means of obtaining three dimensional (3D) electron images over volumes much larger than possible by focused ion beam (FIB) serial sectioning and at higher spatial resolution than achievable with conventional X-ray computed tomography (CT). Such high resolution 3D electron images can be employed for precisely determining the shape, volume fraction, distribution and connectivity of important microstructural features. While soft (fixed or frozen) biological samples are particularly well suited for nanoscale sectioning using an ultramicrotome, the technique can also produce excellent 3D images at electron microscope resolution in a time and resource-efficient manner for engineering materials. Currently, a lack of appreciation of the capabilities of ultramicrotomy and the operational challenges associated with minimising artefacts for different materials is limiting its wider application to engineering materials. Consequently, this paper outlines the current state of the art for SBFSEM examining in detail how damage is introduced during slicing and highlighting strategies for minimising such damage. A particular focus of the study is the acquisition of 3D images for a variety of metallic and coated systems. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  3. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Directory of Open Access Journals (Sweden)

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  4. Dissecting Costs of CT Study: Application of TDABC (Time-driven Activity-based Costing) in a Tertiary Academic Center.

    Science.gov (United States)

    Anzai, Yoshimi; Heilbrun, Marta E; Haas, Derek; Boi, Luca; Moshre, Kirk; Minoshima, Satoshi; Kaplan, Robert; Lee, Vivian S

    2017-02-01

    The lack of understanding of the real costs (not charge) of delivering healthcare services poses tremendous challenges in the containment of healthcare costs. In this study, we applied an established cost accounting method, the time-driven activity-based costing (TDABC), to assess the costs of performing an abdomen and pelvis computed tomography (AP CT) in an academic radiology department and identified opportunities for improved efficiency in the delivery of this service. The study was exempt from an institutional review board approval. TDABC utilizes process mapping tools from industrial engineering and activity-based costing. The process map outlines every step of discrete activity and duration of use of clinical resources, personnel, and equipment. By multiplying the cost per unit of capacity by the required task time for each step, and summing each component cost, the overall costs of AP CT is determined for patients in three settings, inpatient (IP), outpatient (OP), and emergency departments (ED). The component costs to deliver an AP CT study were as follows: radiologist interpretation: 40.1%; other personnel (scheduler, technologist, nurse, pharmacist, and transporter): 39.6%; materials: 13.9%; and space and equipment: 6.4%. The cost of performing CT was 13% higher for ED patients and 31% higher for inpatients (IP), as compared to that for OP. The difference in cost was mostly due to non-radiologist personnel costs. Approximately 80% of the direct costs of AP CT to the academic medical center are related to labor. Potential opportunities to reduce the costs include increasing the efficiency of utilization of CT, substituting lower cost resources when appropriate, and streamlining the ordering system to clarify medical necessity and clinical indications. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  5. CT after transsphenoidal surgery

    International Nuclear Information System (INIS)

    Tazawa, Satoru

    1991-01-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author)

  6. CT after transsphenoidal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Tazawa, Satoru [Tohoku Univ., Sendai (Japan). School of Medicine

    1991-03-01

    Two hundred and ten CT studies of 95 patients after transsphenoidal surgery were reviewed. Spheno-ethmoid opacificaiton, intrasellar hematoma and gas bubbles were noted within 2 weeks after surgery. Bone defect of the sellar floor and bone stent were seen on coronal scans in most cases. The packing material frequently disappeared on follow-up studies. Hormonal assessment of the functioning tumor, according to which the effect of treatment was evaluated, was correlated with CT findings. Because differentiation between postoperative changes and residual mass was difficult, there was no definite CT criteria to indicate residual functioning tumor except upward convexity of the diaphragma sellae on CT more than 3 months after surgery. Initial follow up CT study is recommended to be performed at about 3 months after surgery, at which time the immediate postoperative inflammatory changes have been disappeared. The incidence of recurrence was 3/47 (6%), which was shown on follow-up CT from 4 to 10 years after surgery. Therefore, subsequent CT study should be done in every year or two, taking the clinical symptoms and hormonal data into consideration. (author).

  7. Indeterminate lesions on planar bone scintigraphy in lung cancer patients: SPECT, CT or SPECT-CT?

    International Nuclear Information System (INIS)

    Sharma, Punit; Kumar, Rakesh; Singh, Harmandeep; Bal, Chandrasekhar; Malhotra, Arun; Julka, Pramod Kumar; Thulkar, Sanjay

    2012-01-01

    The objective of the present study was to compare the role of single photon emission computed tomography (SPECT), computed tomography (CT) and SPECT-CT of selected volume in lung cancer patients with indeterminate lesions on planar bone scintigraphy (BS). The data of 50 lung cancer patients (53 ± 10.3 years; range 30-75; male/female 38/12) with 65 indeterminate lesions on planar BS (January 2010 to November 2010) were retrospectively evaluated. All of them underwent SPECT-CT of a selected volume. SPECT, CT and SPECT-CT images were independently evaluated by two experienced readers (experience in musculoskeletal imaging, including CT: 5 and 7 years) in separate sessions. A scoring scale of 1 to 5 was used, in which 1 is definitely metastatic, 2 is probably metastatic, 3 is indeterminate, 4 is probably benign and 5 is definitely benign. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for each modality, taking a score ≤2 as metastatic. With receiver operating characteristic (ROC) curve analysis, areas under the curve (AUC) were calculated for each modality and compared. Clinical and imaging follow-up and/or histopathology were taken as reference standard. For both readers SPECT was inferior to CT (P = 0.004, P = 0.022) and SPECT-CT (P = 0.003, P = 0.037). However, no significant difference was found between CT and SPECT-CT for reader 1 (P = 0.847) and reader 2 (P = 0.592). The findings were similar for lytic as well as sclerotic lesions. Moderate inter-observer agreement was seen for SPECT images (κ = 0.426), while almost perfect agreement was seen for CT (κ = 0.834) and SPECT-CT (κ = 0.971). CT alone and SPECT-CT are better than SPECT for accurate characterisation of indeterminate lesions on planar BS in lung cancer patients. CT alone is not inferior to SPECT-CT for this purpose and might be preferred because of shorter acquisition time and wider availability. (orig.)

  8. Multisource inverse-geometry CT. Part II. X-ray source design and prototype

    Energy Technology Data Exchange (ETDEWEB)

    Neculaes, V. Bogdan, E-mail: neculaes@ge.com; Caiafa, Antonio; Cao, Yang; De Man, Bruno; Edic, Peter M.; Frutschy, Kristopher; Gunturi, Satish; Inzinna, Lou; Reynolds, Joseph; Vermilyea, Mark; Wagner, David; Zhang, Xi; Zou, Yun [GE Global Research, Niskayuna, New York 12309 (United States); Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Lounsberry, Brian [Healthcare Science Technology, GE Healthcare, West Milwaukee, Wisconsin 53219 (United States)

    2016-08-15

    Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent

  9. Evaluation of CT in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Norio; Miura, Yukio; Ohnishi, Mitsunori; Kamikon-ya, Norihiko; Sakamoto, Yoshisato; Miura, Takashi; Sakamoto, Kiyoshi; Takayasu, Yoshio

    1985-06-01

    In order to evaluate the diagnostic ability of CT in hepatocellular carcinoma, four kinds of CT images were comparatively studied by the accuracy and ROC (receiver operating characteristic) curve analysis. As a result, it was clarified that CT images were evaluated more objectively by ROC curve analysis than by accuracy. The diagnostic ability of existence and differentiation of tumor in the liver were higher in order of plain CT, contrast enhanced CT (CECT), bolus CT and CT arteriography (CTA). Therefore, in an usual CT examination intended to make differential diagnosis in space occupying liver disease, bolus CT seems to be indispensable, and also CTA is essential where diagnosis is difficult even by bolus CT.

  10. Low-dose Dental-CT

    International Nuclear Information System (INIS)

    Gahleitner, A.; Imhof, H.; Homolka, P.; Fuerhauser, R.; Freudenthaler, J.; Watzek, G.

    2000-01-01

    Dental-CT is a relatively new, increasingly used investigation technique in dental radiology. Several authors have stated that the indication for Dental-CT has to be chosen on a strict basis, due to high dose values. This article describes the technique of performing dental-CT and calculates the effective dose based on published data and own measurements as well as the dose reduction potential to achieve an optimized protocol for Dental-CT investigations. (orig.) [de

  11. Dose calculation with respiration-averaged CT processed from cine CT without a respiratory surrogate

    International Nuclear Information System (INIS)

    Riegel, Adam C.; Ahmad, Moiz; Sun Xiaojun; Pan Tinsu

    2008-01-01

    Dose calculation for thoracic radiotherapy is commonly performed on a free-breathing helical CT despite artifacts caused by respiratory motion. Four-dimensional computed tomography (4D-CT) is one method to incorporate motion information into the treatment planning process. Some centers now use the respiration-averaged CT (RACT), the pixel-by-pixel average of the ten phases of 4D-CT, for dose calculation. This method, while sparing the tedious task of 4D dose calculation, still requires 4D-CT technology. The authors have recently developed a means to reconstruct RACT directly from unsorted cine CT data from which 4D-CT is formed, bypassing the need for a respiratory surrogate. Using RACT from cine CT for dose calculation may be a means to incorporate motion information into dose calculation without performing 4D-CT. The purpose of this study was to determine if RACT from cine CT can be substituted for RACT from 4D-CT for the purposes of dose calculation, and if increasing the cine duration can decrease differences between the dose distributions. Cine CT data and corresponding 4D-CT simulations for 23 patients with at least two breathing cycles per cine duration were retrieved. RACT was generated four ways: First from ten phases of 4D-CT, second, from 1 breathing cycle of images, third, from 1.5 breathing cycles of images, and fourth, from 2 breathing cycles of images. The clinical treatment plan was transferred to each RACT and dose was recalculated. Dose planes were exported at orthogonal planes through the isocenter (coronal, sagittal, and transverse orientations). The resulting dose distributions were compared using the gamma (γ) index within the planning target volume (PTV). Failure criteria were set to 2%/1 mm. A follow-up study with 50 additional lung cancer patients was performed to increase sample size. The same dose recalculation and analysis was performed. In the primary patient group, 22 of 23 patients had 100% of points within the PTV pass γ criteria

  12. CT pelvimetry

    International Nuclear Information System (INIS)

    Vicens, J.L.; Charles, G.; Le Berre, J.; Flageat, J.

    1989-01-01

    Pelvimetry aims at providing the obstetrician with information on the size and morphology of the female pelvis, thus enabling him to assess the obstetrical prognosis as accurately as possible. Computed tomography (CT) has several advantages, in particular the lower mother and fetus radiation dose. After a brief description of obstetrical anatomy, the usual CT exploration method is presented and its results are considered in terms of measurements, indices and morphological findings. If performed with a very strict exploration procedure, CT pelvimetry is a very reliable, fact and comfortable method of examination. All these advantages, combined with the minimized patient dose, should lead to an increasingly widespread use of this technique [fr

  13. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  15. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM); Funktionelle Computertomographie: Beanspruchungsabhaengige Darstellung der subchondralen Mineralisierung mittels CT gestuetzter Osteoabsorptiometrie (CTOAM)

    Energy Technology Data Exchange (ETDEWEB)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M. [Inst. fuer Klinische Radiologie, Innenstadt, Ludwig-Maximilians-Univ. Muenchen (Germany); Kersting, S.; Putz, R.; Mueller-Gerbl, M. [Anatomische Anstalt, Ludwig-Maximilians-Univ. Muenchen (Germany)

    2003-05-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p < 0.001). Conclusion: CT-OAM is a functional CT technique for visualizing and quantifying the distribution of the subchondral bone density, enabling a noninvasive load-dependent assessment of the joint surfaces. Load-dependent densitograms of hallux valgus specimens show a characteristic correlation with an increase of the HV-angle. (orig.) [German] Ziel: Darstellung und Quantifizierung der subchondralen Mineralisierung in Abhaengigkeit von unterschiedlichen Beanspruchungssituationen mittels funktioneller Computertomographie als CT-Osteoabsorptiometrie (CT-OAM). Methode: An 46 humanen Praeparaten mit Hallux valgus (HV) wurden exemplarisch die TMT I (Tarsometatarsal)- und MTP I (Metatarsophalangeal)-Gelenke des ersten Strahles (sagittal 1/1/1 mm) an einem Singleslice Spiral-CT (SCT, Somatom Plus 4, Siemens AG) untersucht. Der subchondrale Knochen wurde segmentiert, den Pixel wurde mittels Volume Rendering Technik (VRT) 10 Graustufenbereiche (D100 HU

  16. CT scans in young people in Northern England: trends and patterns 1993-2002

    Energy Technology Data Exchange (ETDEWEB)

    Pearce, Mark S.; Salotti, Jane A.; Metcalf, Wenhua [Newcastle University, Sir James Spence Institute, Royal Victoria Infirmary, Institute of Health and Society, Newcastle upon Tyne (United Kingdom); McHugh, Kieran [Great Ormond Street Hospital for Children NHS Trust, London (United Kingdom); Kim, Kwang P. [Kyung Hee University, Department of Nuclear Engineering, Gyeongi-Do (Korea, Republic of); Craft, Alan W. [Newcastle University, Northern Institute of Cancer Research, Sir James Spence Institute, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom); Parker, Louise [Dalhousie University and Cancer Care Nova Scotia, Departments of Medicine and Paediatrics, Population Cancer Research Program, Halifax, NS (Canada); Ron, Elaine [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States)

    2011-07-15

    Although CT can be greatly beneficial, its relatively high radiation doses have caused public health concerns. To assess patterns in CT usage among patients aged less than 22 years in Northern England during the period 1993-2002. Electronic data were obtained from radiology information systems of all nine National Health Service trusts in the region. A total of 38,681 scans had been performed in 20,483 patients aged less than 22 years. The number of CT examinations rose, with the steepest increase between 1997 and 2000. The number of patients scanned per year increased less dramatically, with 2.24/1,000 population aged less than 22 years having one scan or more in 1993 compared to 3.54/1,000 in 2002. This reflects an increase in the median number of scans per patient, which rose from 1 in 1993 to 2 by 1999. More than 70% of CT examinations were of the head, with the number of head examinations varying with time and patient age. The frequency of CT scans in this population more than doubled during the study period. This is partly, but not wholly, explained by an increase in the number of scans per patient. (orig.)

  17. FDG-PET/contrast-enhanced CT as a post-treatment tool in head and neck squamous cell carcinoma: comparison with FDG-PET/non-contrast-enhanced CT and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Yuko; Kitajima, Kazuhiro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe (Japan); Ishihara, Takeaki; Sasaki, Ryohei [Kobe University Graduate, School of Medicine, Department of Radiology, Division of Radiation Oncology, Kobe (Japan); Otsuki, Naoki; Nibu, Ken-ichi [Kobe University Graduate, School of Medicine, Department of Otolaryngology-Head and Neck Surgery, Kobe (Japan); Minamikawa, Tsutomu [Kobe University Graduate School of Medicine, Department of Oral and Maxillofacial Surgery, Kobe (Japan); Kiyota, Naomi [Kobe University Hospital, Department of Medical Oncology and Hematology, Kobe (Japan)

    2016-04-15

    To evaluate the accuracy of PET/CT using {sup 18}F-fluorodeoxyglucose (FDG) with IV contrast for suspected recurrent head and neck squamous cell carcinoma (HNSCC). One hundred and seventy patients previously treated for HNSCC underwent PET/CT, consisting of non-contrast-enhanced and contrast-enhanced CT, to investigate suspected recurrence. Diagnostic performance of PET/contrast-enhanced CT (PET/ceCT), PET/non-contrast-enhanced CT (PET/ncCT) and contrast-enhanced CT (ceCT) for local or regional recurrence, distant metastasis, overall recurrence and second primary cancer was evaluated. The reference standard included histopathology, treatment change and imaging follow-up. The patient-based areas under the receiver operating characteristic curves (AUC) for ceCT, PET/ncCT and PET/ceCT were 0.82, 0.96 and 0.98 for local recurrence, 0.73, 0.86 and 0.86 for regional recurrence, 0.86, 0.91 and 0.92 for distant metastasis, 0.72, 0.86 and 0.87 for overall recurrence, and 0.86, 0.89 and 0.91 for a second primary cancer. Both PET/ceCT and PET/ncCT statistically showed larger AUC than ceCT for recurrence, and the difference between PET/ceCT and PET/ncCT for local recurrence reached a significant level (p = 0.039). The accuracy of PET/ceCT for diagnosing overall recurrence was high, irrespective of the time interval after the last treatment (83.3-94.1 %). FDG-PET/CT was a more accurate HNSCC restaging tool than ceCT. The added value of ceCT at FDG-PET/CT is minimal. (orig.)

  18. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  19. Improved quantitation and reproducibility in multi-PET/CT lung studies by combining CT information.

    Science.gov (United States)

    Holman, Beverley F; Cuplov, Vesna; Millner, Lynn; Endozo, Raymond; Maher, Toby M; Groves, Ashley M; Hutton, Brian F; Thielemans, Kris

    2018-06-05

    Matched attenuation maps are vital for obtaining accurate and reproducible kinetic and static parameter estimates from PET data. With increased interest in PET/CT imaging of diffuse lung diseases for assessing disease progression and treatment effectiveness, understanding the extent of the effect of respiratory motion and establishing methods for correction are becoming more important. In a previous study, we have shown that using the wrong attenuation map leads to large errors due to density mismatches in the lung, especially in dynamic PET scans. Here, we extend this work to the case where the study is sub-divided into several scans, e.g. for patient comfort, each with its own CT (cine-CT and 'snap shot' CT). A method to combine multi-CT information into a combined-CT has then been developed, which averages the CT information from each study section to produce composite CT images with the lung density more representative of that in the PET data. This combined-CT was applied to nine patients with idiopathic pulmonary fibrosis, imaged with dynamic 18 F-FDG PET/CT to determine the improvement in the precision of the parameter estimates. Using XCAT simulations, errors in the influx rate constant were found to be as high as 60% in multi-PET/CT studies. Analysis of patient data identified displacements between study sections in the time activity curves, which led to an average standard error in the estimates of the influx rate constant of 53% with conventional methods. This reduced to within 5% after use of combined-CTs for attenuation correction of the study sections. Use of combined-CTs to reconstruct the sections of a multi-PET/CT study, as opposed to using the individually acquired CTs at each study stage, produces more precise parameter estimates and may improve discrimination between diseased and normal lung.

  20. Lecithin-coated gold nanoflowers (GNFs) for CT scan imaging applications and biochemical parameters; in vitro and in vivo studies.

    Science.gov (United States)

    Aziz, Farooq; Bano, Khizra; Siddique, Ahmad Hassan; Bajwa, Sadia Zafar; Nazir, Aalia; Munawar, Anam; Shaheen, Ayesha; Saeed, Madiha; Afzal, Muhammad; Iqbal, M Zubair; Wu, Aiguo; Khan, Waheed S

    2018-01-09

    We report a novel strategy for the fabrication of lecithin-coated gold nanoflowers (GNFs) via single-step design for CT imaging application. Field-emission electron microscope confirmed flowers like morphology of the as-synthesized nanostructures. Furthermore, these show absorption peak in near-infrared (NIR) region at λ max 690 nm Different concentrations of GNFs are tested as a contrast agent in CT scans at tube voltage 135 kV and tube current 350 mA. These results are compared with same amount of iodine at same CT scan parameters. The results of in vitro CT scan study show that GNFs have good contrast enhancement properties, whereas in vivo study of rabbits CT scan shows that GNFs enhance the CT image clearly at 135 kV as compared to that of iodine. Cytotoxicity was studied and blood profile show minor increase of white blood cells and haemoglobin, whereas decrease of red blood cells and platelets.

  1. Physics and basic technology of CT

    International Nuclear Information System (INIS)

    Mahesh, Mahadevappa

    2017-01-01

    Computed Tomography is one of the prime imaging modalities in any hospital around the globe. From its inception in 1973, CT technology have advanced leaps and bounds in medical diagnosis. Advances in X-ray tubes, detection technologies and image reconstruction methods led to the development of multiple-row detector CT (MDCT) technologies in early 2000, that has been the impetus for new fields such as Cardiovascular CT, Hybrid CT (PET-CT and SPECT-CT), CT Perfusion, Cone Beam CT, etc. It is now possible to image the entire organ (such as heart) in less than 0.3 seconds providing isotropic resolution images with high temporal resolution. With all X-ray imaging modalities, including CT, the concern is the radiation dose. Since CT procedures are one of the major imaging procedures performed in any hospital, it is important to optimize CT protocols in order to provide quality images at optimal radiation dose

  2. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K [Department of Radiation Oncology, NYU Langone Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  3. SU-F-J-109: Generate Synthetic CT From Cone Beam CT for CBCT-Based Dose Calculation

    International Nuclear Information System (INIS)

    Wang, H; Barbee, D; Wang, W; Pennell, R; Hu, K; Osterman, K

    2016-01-01

    Purpose: The use of CBCT for dose calculation is limited by its HU inaccuracy from increased scatter. This study presents a method to generate synthetic CT images from CBCT data by a probabilistic classification that may be robust to CBCT noise. The feasibility of using the synthetic CT for dose calculation is evaluated in IMRT for unilateral H&N cancer. Methods: In the training phase, a fuzzy c-means classification was performed on HU vectors (CBCT, CT) of planning CT and registered day-1 CBCT image pair. Using the resulting centroid CBCT and CT values for five classified “tissue” types, a synthetic CT for a daily CBCT was created by classifying each CBCT voxel to obtain its probability belonging to each tissue class, then assigning a CT HU with a probability-weighted summation of the classes’ CT centroids. Two synthetic CTs from a CBCT were generated: s-CT using the centroids from classification of individual patient CBCT/CT data; s2-CT using the same centroids for all patients to investigate the applicability of group-based centroids. IMRT dose calculations for five patients were performed on the synthetic CTs and compared with CT-planning doses by dose-volume statistics. Results: DVH curves of PTVs and critical organs calculated on s-CT and s2-CT agree with those from planning-CT within 3%, while doses calculated with heterogeneity off or on raw CBCT show DVH differences up to 15%. The differences in PTV D95% and spinal cord max are 0.6±0.6% and 0.6±0.3% for s-CT, and 1.6±1.7% and 1.9±1.7% for s2-CT. Gamma analysis (2%/2mm) shows 97.5±1.6% and 97.6±1.6% pass rates for using s-CTs and s2-CTs compared with CT-based doses, respectively. Conclusion: CBCT-synthesized CTs using individual or group-based centroids resulted in dose calculations that are comparable to CT-planning dose for unilateral H&N cancer. The method may provide a tool for accurate dose calculation based on daily CBCT.

  4. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  5. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  6. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  7. CT-docking patient stretcher

    International Nuclear Information System (INIS)

    Mirvis, S.E.; Owens, E.; Maslyn, J.; Rizutto, M.

    1990-01-01

    This paper assesses the use of a patient stretcher that directly docks to a CT scanner for acutely injured and/or critically ill patients. The stretcher permits performance of radiography and acts as a platform for critical care monitoring and patient support devices. During a 1-year period, the prototype CT-docking stretcher was used for 35 patients sustaining acute trauma and 25 patients from critical care units. Observations were elicited from physicians, nurses and technologists concerning the advantages or disadvantages of the docking stretcher. Advantages of the CT-docking stretcher included time saved in moving patients to the CT table from the admitting/emergency ward, transfer of critically ill patients onto the stretcher in the controlled environment of the intensive care unit rather than the CT suite, increasing CT throughput by direct docking of the patient stretcher to the CT scanner rather than manual transfer of complex support and monitoring devices with the patient, decreased risk associated with physical movement of patients with potentially unstable spinal injuries or unstable physiologic status, and decrease in potential for injury to medical personnel performing patient transfer

  8. Radiation dose and cancer risk from pediatric CT examinations on 64-slice CT: A phantom study

    International Nuclear Information System (INIS)

    Feng Shiting; Law, Martin Wai-Ming; Huang Bingsheng; Ng, Sherry; Li Ziping; Meng Quanfei; Khong, Pek-Lan

    2010-01-01

    Objective: To measure the radiation dose from CT scans in an anthropomorphic phantom using a 64-slice MDCT, and to estimate the associated cancer risk. Materials and methods: Organ doses were measured with a 5-year-old phantom and thermoluminescent dosimeters. Four protocols; head CT, thorax CT, abdomen CT and pelvis CT were studied. Cancer risks, in the form of lifetime attributable risk (LAR) of cancer incidence, were estimated by linear extrapolation using the organ radiation doses and the LAR data. Results: The effective doses for head, thorax, abdomen and pelvis CT, were 0.7 mSv, 3.5 mSv, 3.0 mSv, 1.3 mSv respectively. The organs with the highest dose were; for head CT, salivary gland (22.33 mGy); for thorax CT, breast (7.89 mGy); for abdomen CT, colon (6.62 mGy); for pelvis CT, bladder (4.28 mGy). The corresponding LARs for boys and girls were 0.015-0.053% and 0.034-0.155% respectively. The organs with highest LARs were; for head CT, thyroid gland (0.003% for boys, 0.015% for girls); for thorax CT, lung for boys (0.014%) and breast for girls (0.069%); for abdomen CT, colon for boys (0.017%) and lung for girls (0.016%); for pelvis CT, bladder for both boys and girls (0.008%). Conclusion: The effective doses from these common pediatric CT examinations ranged from 0.7 mSv to 3.5 mSv and the associated lifetime cancer risks were found to be up to 0.16%, with some organs of higher radiosensitivity including breast, thyroid gland, colon and lungs.

  9. Preoperative staging of lung cancer with PET/CT: cost-effectiveness evaluation alongside a randomized controlled trial

    DEFF Research Database (Denmark)

    Søgaard, Rikke; Fischer, Barbara Malene B; Mortensen, Jann

    2011-01-01

    PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost-effective......PURPOSE: Positron emission tomography (PET)/CT has become a widely used technology for preoperative staging of non-small cell lung cancer (NSCLC). Two recent randomized controlled trials (RCT) have established its efficacy over conventional staging, but no studies have assessed its cost......-effectiveness. The objective of this study was to assess the cost-effectiveness of PET/CT as an adjunct to conventional workup for preoperative staging of NSCLC. METHODS: The study was conducted alongside an RCT in which 189 patients were allocated to conventional staging (n = 91) or conventional staging + PET/CT (n = 98......) and followed for 1 year after which the numbers of futile thoracotomies in each group were monitored. A full health care sector perspective was adapted for costing resource use. The outcome parameter was defined as the number needed to treat (NNT)-here number of PET/CT scans needed-to avoid one futile...

  10. CT arteriography of the upper abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, K; Matsuura, K; Baba, H; Numaguchi, Y; Komaki, S [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-04-01

    The technique of CT arteriography was introduced, and CT images of the upper abdomen were explained. Very clear enhancement of parenchyma and vessels (especially portal vein) of the object organs could be obtained by CT arteriography of the upper abdomen, anatomical structures of organs were identified more easily by CT arteriography than by conventional CT, and the amount of information obtained was increased by using CT arteriography. However, the indication of CT arteriography must be limited, because of its complexity that CT arteriography is performed after angiography and involves the invasion of patients' bodies. As described in many reports, CT arteriography is useful for malignant tumors of the liver, and it is worthwhile, especially when surgery for hepatocellular carcinoma is considered. CT arteriography for organs except the liver has not been discussed sufficiently. Therefore, an application of this method for other organs must be decided after consideration of the balance of the amount of information obtained by CT arteriography with invasion to patients.

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  12. Philips Gemini TF64 PET/CT Acceptance Testing

    International Nuclear Information System (INIS)

    González Gonzalez, Joaquín J.; Calderón Marin, Carlos F.; Varela Corona, Consuelo; Machado Tejeda, Adalberto; González Correa, Héctor J.

    2016-01-01

    The Philips Gemini TF64 is the first PET/CT scanner installed in Cuba at the Institute of Oncology and Radiobiology in 2014. It is a third generation fully tridimensional whole body PET scanner with time-of-flight (TOF) technology combined with a 64-slice Brilliance CT scanner. The CT detector module contains 672x64 solid state detector, incorporating GOS scintillators, optical diodes and electronic signal channels arranged in 64 side by side arcs, with 672 detectors in each arc. There are sixteen 0.75 mm individual detector elements around the center and four 1.5 mm elements at each end, resulting in a 24 mm total detection length. The PET detector consists of 28 pixelar modules of a 23x44 array of 4x4x22 mm3 of LYSO crystals arranged in an Anger-logic detector design. The hardware coincidence-timing window for this scanner is set at 4 ns and delayed coincidence window technique is used to estimate the random coincidences in collected data. In this study the performance characteristics of PET/CT scanner were measured as part of the program tests of acceptance for clinical use.Methodology. The performance characteristics of CT scanner were evaluated by manufacturer protocol using Philips system performance phantom. Some additional geometrical tests were performed by the user. The intrinsic measurements of energy resolution as well as timing resolution, which define the TOF performance of PET scanner, were performed following the recommendations of manufacturer using 18 F. Spatial resolution, sensitivity, scatter fraction, counting rate performance, image quality and accuracy were measured according to the NEMA NU-2 2007 procedures. Additionally, to characterize the effect of TOF reconstruction on lesion contrast and noise, the standard NEMA torso phantom was reconstructed with and without TOF capability. The accuracy of PET/CT image registration was tested according to the manufacturer protocol using an image alignment calibration holder with 6 point sources of 22

  13. Functional CT imaging: load-dependent visualization of the subchondral mineralization by means of CT osteoabsorptionmetry (CT-OAM)

    International Nuclear Information System (INIS)

    Linsenmaier, U.; Schlichtenhorst, K.; Pfeifer, K.J.; Reiser, M.; Kersting, S.; Putz, R.; Mueller-Gerbl, M.

    2003-01-01

    Purpose: Functional computed tomography for visualization and quantification of subchondral bone mineralization using CT osteoabsorptiometry (CT-OAM). Materials and Methods: Tarsometatarsal (TMT) and metatarsophalangeal (MTP) joints of 46 human hallux valgus (HV) specimens were examined (sagittal 1/1/1 mm) on a single slice CT scanner SCT (Somatom Plus 4, Siemens AG). Subchondral bone pixels were segmented and assigned to 10 density value groups (triangle 100 HU, range 200 - 1200 HU) the pixels using volume rendering technique (VRT). The data analysis considered the severity of HV as determined by the radiographically measured HV-angle (a.p. projection). Results: CT-OAM could generate reproducible densitograms of the distribution pattern of the subchondral bone density for all four joint surfaces (TMT and MTP joints). The bone density localization enables the assignment to different groups, showing a characteristic HV-angle-dependent distribution of the maximum bone mineralization of the load-dependent densitogram (p [de

  14. X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants

    Science.gov (United States)

    Karch, J.; Dudák, J.; Žemlička, J.; Vavřík, D.; Kumpová, I.; Kvaček, J.; Heřmanová, Z.; Šoltés, J.; Viererbl, L.; Morgano, M.; Kaestner, A.; Trtík, P.

    2017-12-01

    Computed tomography provides 3D information of inner structures of investigated objects. The obtained information is, however, strongly dependent on the used radiation type. It is known that as X-rays interact with electron cloud and neutrons with atomic nucleus, the obtained data often provide different contrast of sample structures. In this work we present a set of comparative radiographic and CT measurements of rare fossil plant samples using X-rays and thermal neutrons. The X-ray measurements were performed using large area photon counting detectors Timepix at IEAP CTU in Prague and Perkin Elmer flat-panel detector at Center of Excellence Telč. The neutron CT measurement was carried out at Paul Scherrer Institute using BOA beam-line. Furthermore, neutron radiography of fossil samples, provided by National Museum, were performed using a large-area Timepix detector with a neutron-sensitive converting 6LiF layer at Research Centre Rez, Czech Republic. The obtained results show different capabilities of both imaging approaches. While X-ray micro-CT provides very high resolution and enables visualization of fine cracks or small cavities in the samples neutron imaging provides high contrast of morphological structures of fossil plant samples, where X-ray imaging provides insufficient contrast.

  15. CT diagnosis of the primary lung cancer and usefulness of biopsy under CT

    International Nuclear Information System (INIS)

    Fujisawa, Hidefumi; Kushihashi, Tamio

    2011-01-01

    CT especially plays an important role in imaging diagnosis of lung cancer (LC) which gives quite multiple CT findings and this paper describes details to be noted for CT findings of individual lung lesion and cancer according to 5 classes below, together with usefulness of CT-guided biopsy and positron emission tomography (PET) usage. Explained are as follows: Important points in histopathology and CT findings from adenomatous hyperplasia (AH) to atypical AH (pre-invasive lesion); Differential CT diagnosis of benignity or malignancy of pulmonary nodes and tumors; Typical CT findings of LC of peripheral type of invasive or exclusive proliferative type, and pulmonary hillar type; Atypical CT findings of LC/having atypical inner structure such as presenting atypical calcification and atypical cavity/having atypical morphology such as presenting pneumonia-like finding, exhibiting regular or linear edge, and existing at atypical region like extrapleural lumen /having atypical progression rate such as showing rapid or slow doubling time of the volume and shrinking tentatively during the progress/of juvenile LC/and generated from background lung diseases such as interstitial pneumonia, tuberculosis, pneumoconiosis like asbestosis, pneumosilicosis, and pulmonary emphysema and bulla; and Regional ground glass opacity. As well, authors mention about the usefulness of CT-guided needle biopsy of the pulmonary lesion which enables to take the nodal specimen as small as <10 mm. Most frequent complication of the biopsy is pneumothorax (10-50%). How to use PET for LC examination is also commented with its usability and limitation. (T.T.)

  16. Lipeo-sCT: a novel reversible lipidized salmon calcitonin derivative, its biophysical properties and hypocalcemic activity.

    Science.gov (United States)

    Cheng, Weiqiang; Lim, Lee-Yong

    2009-05-12

    We have previously described the design and synthesis of Mal-sCT and compared its biological activity with its reversible counterpart, REAL-sCT. Mal-sCT was salmon calcitonin (sCT) conjugated with two molecules of an epsilon-maleimido lysine derivative of palmitic acid via non-reversible thioether bonds at its cysteine residues while REAL-sCT was sCT conjugated with two molecules of a cysteine derivative of palmitic acid via reducible disulfide bonds at its cysteine residues. Neither compounds when dissolved in water could reproducibly improved the oral deliverability of sCT. The purpose of this study was to characterize and evaluate Lipeo-sCT, a novel sCT analog conjugated via reducible disulfide bonds with two amphiphilic groups consisting of a hydrophobic hexadecyl moiety attached via an ether bond to a hydrophilic triethylene glycol moiety. Lipeo-sCT was successfully synthesized by a 4-step reaction, purified and identified by ESI-MS. Analysis by dynamic light scattering (DLS) and transmission electron microscopy (TEM) suggested it had a propensity to form aggregates in water, although the aggregation behavior was controllable by modulating solvent polarity. MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay indicated a lack of cytotoxicity against the Caco-2 cells at up to 100 microM. Compared with sCT, Lipeo-sCT lowered plasma calcium to comparable levels when injected subcutaneously at 0.15 mg/kg into female Wistar rats, but the hypocalcemic activity of Lipeo-sCT was prolonged by at least 6 more hours. This was attributable to a continual regeneration of sCT from Lipeo-sCT. sCT was detectable in plasma 8h following subcutaneous injection of Lipeo-sCT (1.90 mg/kg), while Lipeo-sCT was not observed in plasma at all time points. By comparison, sCT was detectable in plasma for less than 2.5h following subcutaneous injection at an equivalent dose (1.50mg/kg). Data from this study complement those of previous studies, and add to the body of

  17. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.

  18. CT of thymoma

    Energy Technology Data Exchange (ETDEWEB)

    Sone, S.; Higashihara, T.; Morimoto, S.; Ikezoe, J.; Arisawa, J. (Osaka Univ. (Japan). Faculty of Medicine)

    1982-08-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cass with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contours with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images.

  19. Study of Image Quality From CT Scanner Multi-Detector by using Americans College of Radiology (ACR) Phantom

    Science.gov (United States)

    Mulyadin; Dewang, Syamsir; Abdullah, Bualkar; Tahir, Dahlang

    2018-03-01

    In this study, the image quality of CT scan using phantom American College of Radiology (ACR) was determined. Scanning multidetector CT is used to know the image quality parameters by using a solid phantom containing four modules and primarily from materials that are equivalent to water. Each module is 4 cm in diameter and 20 cm in diameter. There is white alignment marks painted white to reflect the alignment laser and there are also “HEAD”, “FOOT”, and “TOP” marks on the phantom to help align. This test obtains CT images of each module according to the routine inspection protocol of the head. Acceptance of image quality obtained for determination: CT Number Accuracy (CTN), CT Number Uniformity and Noise, Linearity CT Number, Slice Technique, Low Contrast Resolution and High Contrast Resolution represent image quality parameters. In testing CT Number Accuracy (CTN), CT Uniform number and Noise are in the range of tolerable values allowed. In the test, Linearity CT Number obtained correlation value above 0.99 is the relationship between electron density and CT Number. In a low contrast resolution test, the smallest contrast groups are visible. In contrast, the high resolution is seen up to 7 lp/cm. The quality of GE CT Scan is very high, as all the image quality tests obtained are within the tolerance brackets of values permitted by the Nuclear Power Control Agency (BAPETEN). Image quality test is a way to get very important information about the accuracy of snoring result by using phantom ACR.

  20. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  1. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Madsen, Poul Henning [Vejle Hospital, Department of Medicine, Division of Respiratory Medicine, Vejle (Denmark); Holdgaard, Paw Christian [Vejle Hospital, Department of Nuclear Medicine, Vejle (Denmark); Christensen, Janne Buck [Odense University Hospital/University of Southern Denmark, Department of Quality and Research/HTA, Odense University Hospital and Medical Research Library, Odense (Denmark); Hoeilund-Carlsen, Poul Flemming [Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark)

    2016-10-15

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: (1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). (2) PET-CT reduces the number of futile treatment trials (recommendation level A). (3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). (1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (<1 cm) and non-solid, solitary pulmonary nodules. These abnormalities should be followed up by CT in a structured programme. (2) No curative-intent treatment should be commenced until a PET-CT scan has excluded occult distant metastases. (3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out. (orig.)

  2. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer

    International Nuclear Information System (INIS)

    Madsen, Poul Henning; Holdgaard, Paw Christian; Christensen, Janne Buck; Hoeilund-Carlsen, Poul Flemming

    2016-01-01

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: (1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). (2) PET-CT reduces the number of futile treatment trials (recommendation level A). (3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). (1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (<1 cm) and non-solid, solitary pulmonary nodules. These abnormalities should be followed up by CT in a structured programme. (2) No curative-intent treatment should be commenced until a PET-CT scan has excluded occult distant metastases. (3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out. (orig.)

  3. Electronic resources of the rare books and valuable editions department of the Central Scientific Library of the V.N. Karazin Kharkiv National University: open access for research

    Directory of Open Access Journals (Sweden)

    І. К. Журавльова

    2014-12-01

    Full Text Available The article describes tasks that electronic collections of rare books fulfill: broad access for readers to rare and valuable editions providing, preservation of ensuring of the original. On the example of the electronic collection of the Central Scientific Library of the V.N. Karazin Kharkiv National University – «eScriptorium: electronic archive of rare books and manuscripts for research and education» the possibility of the full-text resources of the valuable editions using is shown. The principles of creation, structure, chronological frameworks, directions of adding the documents to the archive are represented. The perspectives of the project development are outlined as well as examples of the digital libraries of the European countries and Ukraine are provided, the actual task of preserving the originals of the rare books of the country is raised, the innovative approaches to serving users with electronic resources are considered. The evidences of cooperation of the Central Scientific Library of the V.N. Karazin Kharkiv National University with the largest world digital libraries: World Digital Library and Europeana are provided.

  4. Computed Tomography (CT) -- Sinuses

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  6. Abdominal and Pelvic CT

    Medline Plus

    Full Text Available ... vessels. CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT is less sensitive to patient movement ...

  7. Clinical utility of F-18 FDG PET-CT in the initial evaluation of lung cancer.

    Science.gov (United States)

    Madsen, Poul Henning; Holdgaard, Paw Christian; Christensen, Janne Buck; Høilund-Carlsen, Poul Flemming

    2016-10-01

    Positron emission tomography-computed tomography (PET-CT) is a resource-demanding imaging modality with increasing popularity in the workup of patients with suspected or proven lung cancer. To review the clinical usefulness of this imaging modality in the diagnosis, staging, and pre-operative evaluation, we conducted a systematic literature search, review, and quality assessment using the rapid evidence assessment toolkit and the Oxford Centre for Evidence-Based Medicine methodology. The literature search resulted in 4,208 records including 918 reviews, of which 139 met the predefined criteria and were read in full to identify relevant original articles on F-18 FDG PET-CT (1) in the evaluation of solitary pulmonary nodules (n = 14), (2) in curative-intent treatment trials (n = 9), and (3) in planning of invasive procedures (n = 18). We found the following important results from the literature review: 1) PET-CT can rule out malignancy in most solitary pulmonary nodules due to high sensitivity (recommendation level A). 2) PET-CT reduces the number of futile treatment trials (recommendation level A). 3) The sensitivity of PET-CT in general is insufficient to rule out mediastinal lymph node metastasis (recommendation level A). ᅟ 1) With few exceptions, solitary pulmonary nodules can safely be considered benign if the PET-CT scan is negative. Exceptions consist of small (PET-CT scan has excluded occult distant metastases. 3) In general, lymph node metastasis in the mediastinum cannot be ruled out on the basis of a negative PET-CT, and confirmative invasive staging should be performed in most patients before mediastinal metastasis is confirmed or ruled out.

  8. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  9. Brain tumor and CT, 1

    International Nuclear Information System (INIS)

    Suzuki, Nobuyuki; Katada, Kazuhiro; Shinomiya, Youichi; Sano, Hirotoshi; Kanno, Tetsuo

    1981-01-01

    It is very important for a neurosurgeon to know the consistency of a brain tumor preoperatively, since the information which is of much use in indicating the likely difficulty of the operation, which operative tools should be selected, the amount of bleeding to be expected from the tumor, and so on. The authors, therefore, tried to evaluate the consistency of brain tumors preoperatively 27 cases in which the margin of the tumor was made clear with a homogeneous stain were studied concerning the relationship between the tumor consistency and the CT findings. The results are as follows: 1) A higher CT number on a plain CT indicated a harder consistency of the tumor. 2) A lesser contrast index (CT number on enhancement CT/CT number on plain CT) showed a harder consistency of the tumor. (author)

  10. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  11. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  12. PET/CT and radiotherapy

    International Nuclear Information System (INIS)

    Messa, C.; CNR, Milano; S. Gerardo Hospital, Monza; Di Muzio, N.; Picchio, M.; Bettinardi, V.; Gilardi, M.C.; CNR, Milano; San Raffaele Scientific Institute, Milano; Fazio, F.; CNR, Milano; San Raffaele Scientific Institute, Milano; San Raffaele Scientific Institute, Milano

    2006-01-01

    This article reviews the state of the art of PET/CT applications in radiotherapy, specifically its use in disease staging, patient selection, treatment planning and treatment evaluation. Diseases for which radiotherapy with radical intent is indicated will be considered, as well as those in which PET/CT may actually change the course of disease. The methodological and technological aspects of PET/CT in radiotherapy are discussed, focusing on the problem of target volume definition with CT and PET functional imaging and the problem of tumor motion with respect to imaging and dose delivery

  13. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  14. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  15. Synergy between pathogen release and resource availability in plant invasion

    Czech Academy of Sciences Publication Activity Database

    Blumenthal, D.; Mitchell, C. E.; Pyšek, Petr; Jarošík, Vojtěch

    2009-01-01

    Roč. 106, č. 19 (2009), s. 7899-7904 ISSN 0027-8424 R&D Projects: GA MŠk LC06073 Grant - others:Evropská komise(XE) GOCE-CT-2003-506675 Institutional research plan: CEZ:AV0Z60050516 Keywords : plant invasions * enemy release * resource availability Subject RIV: EG - Zoology Impact factor: 9.432, year: 2009

  16. Adenocarcinoma Prostate With Neuroendocrine Differentiation: Potential Utility of 18F-FDG PET/CT and 68Ga-DOTANOC PET/CT Over 68Ga-PSMA PET/CT.

    Science.gov (United States)

    Parida, Girish Kumar; Tripathy, Sarthak; Datta Gupta, Shreya; Singhal, Abhinav; Kumar, Rakesh; Bal, Chandrasekhar; Shamim, Shamim Ahmed

    2018-04-01

    Ga-PSMA PET/CT is the upcoming imaging modality for staging, restaging and response assessment of prostate cancer. However, due to neuroendocrine differentiation in some of patients with prostate cancer, they express somatostatin receptors instead of prostate specific membrane antigen. This can be exploited and other modalities like Ga-DOTANOC PET/CT and F-FDG PET/CT should be used in such cases for guiding management. We hereby discuss a similar case of 67-year-old man of adenocarcinoma prostate with neuroendocrine differentiation, which shows the potential pitfall of Ga-PSMA PET/CT imaging and benefit of Ga-DOTANOC PET/CT and F-FDG PET/CT in such cases.

  17. Electronic tracking of human resource skills and knowledge, just in time training, manageable due diligence

    Energy Technology Data Exchange (ETDEWEB)

    Kolodziej, M.A. [Quick Test International Inc., (Canada). Canadian Technology Human Resource Board; Baker, O. [KeySpan Energy Canada, Calgary, AB (Canada)

    2001-06-01

    KeySpan Energy Canada is in the process of obtaining recognition of various occupational profiles including pipeline operators, inspectors, and field and plant operators from various certifying organizations. The process of allowing individuals to obtain certification is recognized by Canadian Technology Human Resources Board as a step towards national standards for technologists and technicians. Proven competency is a must for workers in todays oil industry in response to increasingly stringent government safety regulations, environmental concerns and high public scrutiny. Quick Test international Inc. has developed a management tool in collaboration with end users at KeySpan Energy Canada. It is an electronic, Internet based competency tool for tracking personal competencies and maintaining continued competency. Response to the tool has been favourable. 2 refs., 4 figs.

  18. NMR-CT scanner

    International Nuclear Information System (INIS)

    Kose, Katsumi; Sato, Kozo; Sugimoto, Hiroshi; Sato, Masataka.

    1983-01-01

    A brief explanation is made on the imaging methods for a practical diagnostic NMR-CT scanner : A whole-body NMR-CT scanner utilizing a resistive magnet has been developed by Toshiba in cooperation with the Institute for Solid State Physics, the University of Tokyo. Typical NMR-CT images of volunteers and patients obtained in the clinical experiments using this device are presented. Detailed specifications are also shown about the practical NMR-CTs which are to be put on the market after obtaining the government approval. (author)

  19. CT and HR-CT of exogenous allergic alveolitis

    International Nuclear Information System (INIS)

    Lederer, A.; Kullnig, P.; Pongratz, M.

    1992-01-01

    The CT changes on conventional and high resolution CT in 14 patients with exogeneous allergic alveolitis (EAA) were analysed retrospectively. There were 8 patients with clinically subacute disease, 5 patients in a chronic stage and 1 patient with acute EAA. The appearances and their distribution were examined. Seven of the 8 patients in the subacute stage showed a ground glass pattern and multiple nodules of less than 2 mm. All patients in the chronic stage showed a combination of fine infiltrates, small nodules and irregular linear densities; distortion of the pulmonary pattern was present in 3 cases. The patient with acute EAA showed diffuse dense areas of consolidation in both lungs as well as multiple nodules and a ground glass pattern. The CT appearances of EAA correspond with the basic micropathology and, within the clinical context, permit diagnostic classification. (orig.) [de

  20. IMPaCT - Integration of Missions, Programs, and Core Technologies

    Science.gov (United States)

    Balacuit, Carlos P.; Cutts, James A.; Peterson, Craig E.; Beauchamp, Patricia M.; Jones, Susan K.; Hang, Winnie N.; Dastur, Shahin D.

    2013-01-01

    IMPaCT enables comprehensive information on current NASA missions, prospective future missions, and the technologies that NASA is investing in, or considering investing in, to be accessed from a common Web-based interface. It allows dependencies to be established between missions and technology, and from this, the benefits of investing in individual technologies can be determined. The software also allows various scenarios for future missions to be explored against resource constraints, and the nominal cost and schedule of each mission to be modified in an effort to fit within a prescribed budget.

  1. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  2. Clinical applications of SPECT-CT

    Energy Technology Data Exchange (ETDEWEB)

    Ahmadzadehfar, Hojjat; Biersack, Hans-Juergen (eds.) [University Hospital Bonn (Germany). Dept. of Nuclear Medicine

    2014-06-01

    Covers the full spectrum of clinical applications of SPECT/CT in diagnosis of benign and malignant diseases. Includes chapters on the use of SPECT/CT for dosimetry and for therapy planning. Completely up to date. Many helpful illustrations. SPECT/CT cameras have considerably improved diagnostic accuracy in recent years. Such cameras allow direct correlation of anatomic and functional information, resulting in better localization and definition of scintigraphic findings. In addition to this anatomic referencing, CT coregistration provides superior quantification of radiotracer uptake based on the attenuation correction capabilities of CT. Useful applications of SPECT/CT have been identified not only in oncology but also in other specialties such as orthopedics and cardiology. This book covers the full spectrum of clinical applications of SPECT/CT in diagnosis and therapy planning of benign and malignant diseases. Opening chapters discuss the technology and physics of SPECT/CT and its use for dosimetry. The role of SPECT/CT in the imaging of a range of pathologic conditions is then addressed in detail. Applications covered include, among others, imaging of the thyroid, bone, and lungs, imaging of neuroendocrine tumors, cardiac scintigraphy, and sentinel node scintigraphy. Individual chapters are also devoted to therapy planning in selective internal radiation therapy of liver tumors and bremsstrahlung SPECT/CT. Readers will find this book to be an essential and up-to-date source of information on this invaluable hybrid imaging technique.

  3. Material Discriminated X-Ray CT System by Using New X-Ray Imager with Energy Discriminate Function

    Directory of Open Access Journals (Sweden)

    Toru Aoki

    2008-04-01

    Full Text Available Material discriminated X-ray CT system has been constructed by using conventional X-ray tube (white X-ray source and photon-counting X-ray imager as an application with energy band detection. We have already reported material identify X-ray CT using K-shell edge method elsewhere. In this report the principle of material discrimination was adapted the separation of electron-density and atomic number from attenuation coefficient mapping in X-ray CT reconstructed image in two wavelength X-ray CT method using white X-ray source and energy discriminated X-ray imager by using two monochrome X-ray source method. The measurement phantom was prepared as four kinds material rods (Carbon(C, Iron(Fe, Copper(Cu, Titanium(Ti rods of 3mm-diameter inside an aluminum(Al rod of 20mm-diameter. We could observed material discriminated X-ray CT reconstructed image, however, the discrimination properties were not good than two monochrome X-ray CT method. This results was could be explained because X-ray scattering, beam-hardening and so on based on white X-ray source, which could not observe in two monochrome X-ray CT method. However, since our developed CdTe imager can be detect five energy-bands at the same time, we can use multi-band analysis to decrease the least square error margin. We will be able to obtain more high separation in atomic number mapping in X-ray CT reconstructed image by using this system.

  4. Proton range shift analysis on brain pseudo-CT generated from T1 and T2 MR.

    Science.gov (United States)

    Pileggi, Giampaolo; Speier, Christoph; Sharp, Gregory C; Izquierdo Garcia, David; Catana, Ciprian; Pursley, Jennifer; Amato, Francesco; Seco, Joao; Spadea, Maria Francesca

    2018-05-29

    In radiotherapy, MR imaging is only used because it has significantly better soft tissue contrast than CT, but it lacks electron density information needed for dose calculation. This work assesses the feasibility of using pseudo-CT (pCT) generated from T1w/T2w MR for proton treatment planning, where proton range comparisons are performed between standard CT and pCT. MR and CT data from 14 glioblastoma patients were used in this study. The pCT was generated by using conversion libraries obtained from tissue segmentation and anatomical regioning of the T1w/T2w MR. For each patient, a plan consisting of three 18 Gy beams was designed on the pCT, for a total of 42 analyzed beams. The plan was then transferred onto the CT that represented the ground truth. Range shift (RS) between pCT and CT was computed at R 80 over 10 slices. The acceptance threshold for RS was according to clinical guidelines of two institutions. A γ-index test was also performed on the total dose for each patient. Mean absolute error and bias for the pCT were 124 ± 10 and -16 ± 26 Hounsfield Units (HU), respectively. The median and interquartile range of RS was 0.5 and 1.4 mm, with highest absolute value being 4.4 mm. Of the 42 beams, 40 showed RS less than the clinical range margin. The two beams with larger RS were both in the cranio-caudal direction and had segmentation errors due to the partial volume effect, leading to misassignment of the HU. This study showed the feasibility of using T1w and T2w MRI to generate a pCT for proton therapy treatment, thus avoiding the use of a planning CT and allowing better target definition and possibilities for online adaptive therapies. Further improvements of the methodology are still required to improve the conversion from MRI intensities to HUs.

  5. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  6. CT findings of infant epilepsy

    International Nuclear Information System (INIS)

    Hojoh, Hiroatsu; Kataoka, Kenkichi; Nakagawa, Yoshihiro; Nakano, Shozo; Tomita, Yutaka.

    1982-01-01

    CT diagnosis of infantile epilepsy was evaluated. High incidence of abnormal CT findings in infantile spasms and Lennox-Gastaut syndrome was same as in other reports. Comparison between CT findings and neurological complications and that between CT findings and electroencephalogram findings revealed a stronger relationship existing in the former. This suggested that CT is more useful as a measure to detect underlying diseases which are due to organic change of the brain to cause epilepsy, rather than as that to disclose epileptic primary lesions of functional change. (Ueda, J.)

  7. CT of thymoma

    International Nuclear Information System (INIS)

    Sone, Shusuke; Higashihara, Tokuro; Morimoto, Shizuo; Ikezoe, Junpei; Arisawa, Jun

    1982-01-01

    Based on 17 patients with thymoma (8 with myasthenia gravis and 9 free from it); 1. The effectiveness of CT, conventional radiography and pneumomediastinography in the detection of thymomas was determined and the results compared. 2. The CT findings of thymomas were discussed and the CT features which seemed to suggest malignant thymomas were evaluated. The results were as follows: 1. Of the 17 cases with thymomas, 13 were diagnosed from p-a films, 13 from lateral films, and 16 from CT. Of the 16 thymomas, 14 were diagnosed from lateral tomography. Mass densities were shown in all 15 cases in which pneumomediastinography were performed. 2. Benign thymomas showed round or oval smoothly marginated mass. The fatty plane between the mass and the mediastinal structures was nicely preserved. 3. Malignant thymoma frequently showed a plaque-like mass with more or less irregular or lobulated contoures with obliteration of the fatty planes of the cardiovascular structures. Tumor calcification was shown in 4 of 10 malignant thymomas. 4. Slight tumor invasion to the mediastinal pleura and lung was difficult to predict from the CT images. (author)

  8. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  9. PET/CT manifestation of the meniscus sign of ulcerating gastric carcinoma

    International Nuclear Information System (INIS)

    Bahk, Yong Whee

    2007-01-01

    Meniscus-like presentation of ulcerating gastric carcinoma on upper gastrointestinal series radiograph was first described in 1921 by Carman and has since been known as a useful differential diagnostic sign in radiology. In 1982 using then newly introduced computed tomography (CT) Widder and Mueller revisited the meniscus sign. Their study was primarily focused on a dynamic assessment of the demonstrability of the meniscus sign that largely depends on the judgment and technical skill of examiner, especially graded compression and patient positioning. One year earlier Balfe et al. assessed the diagnostic reliability of gastric wall thickening as observed on CT scan in adenocarcinoma, lymphoma and leiomyosarcoma and concluded that it is not a reliable finding. In contrast, however, Lee et al. recently emphasized that the wall thickness measurement on CT of exophytic carcinoma, myoma and ulcers was a useful diagnostic means. Thus, it appears that gastric wall thickening or mucosal heave-up is by itself not as reliable as the meniscus sign. The electronic search of world literature failed to disclose earlier report of this sign demonstrated by 18 F-FDG positron emission tomography and computed tomography (PET/CT). The present communication documents 18 F-FDG PET/CT finding of the meniscus sign as encountered in a case of ulcerating gastric carcinoma, the histological diagnosis of which was moderately differentiated tubular adenocarcinoma. Unlike most gastric tumors without ulceration that tend to unimpressively accumulate 18 F-FDG the present case of Borrmann type III gastric carcinoma demonstrated markedly increased 18 F-FDG uptake

  10. The Biomedical Resource Ontology (BRO) to enable resource discovery in clinical and translational research.

    Science.gov (United States)

    Tenenbaum, Jessica D; Whetzel, Patricia L; Anderson, Kent; Borromeo, Charles D; Dinov, Ivo D; Gabriel, Davera; Kirschner, Beth; Mirel, Barbara; Morris, Tim; Noy, Natasha; Nyulas, Csongor; Rubenson, David; Saxman, Paul R; Singh, Harpreet; Whelan, Nancy; Wright, Zach; Athey, Brian D; Becich, Michael J; Ginsburg, Geoffrey S; Musen, Mark A; Smith, Kevin A; Tarantal, Alice F; Rubin, Daniel L; Lyster, Peter

    2011-02-01

    The biomedical research community relies on a diverse set of resources, both within their own institutions and at other research centers. In addition, an increasing number of shared electronic resources have been developed. Without effective means to locate and query these resources, it is challenging, if not impossible, for investigators to be aware of the myriad resources available, or to effectively perform resource discovery when the need arises. In this paper, we describe the development and use of the Biomedical Resource Ontology (BRO) to enable semantic annotation and discovery of biomedical resources. We also describe the Resource Discovery System (RDS) which is a federated, inter-institutional pilot project that uses the BRO to facilitate resource discovery on the Internet. Through the RDS framework and its associated Biositemaps infrastructure, the BRO facilitates semantic search and discovery of biomedical resources, breaking down barriers and streamlining scientific research that will improve human health. Copyright © 2010 Elsevier Inc. All rights reserved.

  11. SedCT: MATLAB™ tools for standardized and quantitative processing of sediment core computed tomography (CT) data collected using a medical CT scanner

    Science.gov (United States)

    Reilly, B. T.; Stoner, J. S.; Wiest, J.

    2017-08-01

    Computed tomography (CT) of sediment cores allows for high-resolution images, three-dimensional volumes, and down core profiles. These quantitative data are generated through the attenuation of X-rays, which are sensitive to sediment density and atomic number, and are stored in pixels as relative gray scale values or Hounsfield units (HU). We present a suite of MATLAB™ tools specifically designed for routine sediment core analysis as a means to standardize and better quantify the products of CT data collected on medical CT scanners. SedCT uses a graphical interface to process Digital Imaging and Communications in Medicine (DICOM) files, stitch overlapping scanned intervals, and create down core HU profiles in a manner robust to normal coring imperfections. Utilizing a random sampling technique, SedCT reduces data size and allows for quick processing on typical laptop computers. SedCTimage uses a graphical interface to create quality tiff files of CT slices that are scaled to a user-defined HU range, preserving the quantitative nature of CT images and easily allowing for comparison between sediment cores with different HU means and variance. These tools are presented along with examples from lacustrine and marine sediment cores to highlight the robustness and quantitative nature of this method.

  12. CT imaging in a large part of the world: what we know and what we can learn

    Energy Technology Data Exchange (ETDEWEB)

    Rehani, Madan M. [Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)

    2014-10-15

    This paper describes how cooperation among international organizations, as modeled in Europe, can work to improve imaging safety and standards for children throughout the world. This is demonstrated in the mechanisms employed in a large-scale multi-national study on CT imaging safety practices described elsewhere in this issue of Pediatric Radiology. Here we learn approaches through which CT safety standards have been achieved and the international resources available to help in standardizing safety practices in medical imaging. There are unique strengths of the approach in Europe, which has mandatory requirements on member states to facilitate strengthening of radiation protection. Most countries have national regulatory mechanisms for radiation protection in medicine. International organizations play a significant role in supporting projects in lower-resource countries such that a large proportion of radiologic professionals in low-resource countries are trained through assistance by these organizations. Many of these international organizations make it possible for professionals worldwide to download free training material. Collaboration among international organizations and the Image Gently campaign toward consensus with regard to radiation protection can go further than individual opinions in promoting a higher standard of radiation protection around the world. (orig.)

  13. CT imaging in a large part of the world: what we know and what we can learn

    International Nuclear Information System (INIS)

    Rehani, Madan M.

    2014-01-01

    This paper describes how cooperation among international organizations, as modeled in Europe, can work to improve imaging safety and standards for children throughout the world. This is demonstrated in the mechanisms employed in a large-scale multi-national study on CT imaging safety practices described elsewhere in this issue of Pediatric Radiology. Here we learn approaches through which CT safety standards have been achieved and the international resources available to help in standardizing safety practices in medical imaging. There are unique strengths of the approach in Europe, which has mandatory requirements on member states to facilitate strengthening of radiation protection. Most countries have national regulatory mechanisms for radiation protection in medicine. International organizations play a significant role in supporting projects in lower-resource countries such that a large proportion of radiologic professionals in low-resource countries are trained through assistance by these organizations. Many of these international organizations make it possible for professionals worldwide to download free training material. Collaboration among international organizations and the Image Gently campaign toward consensus with regard to radiation protection can go further than individual opinions in promoting a higher standard of radiation protection around the world. (orig.)

  14. Radiation dose associated with CT-guided drain placement for pediatric patients

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G. [University of North Carolina at Chapel Hill, Department of Radiology, UNC Health Care, Chapel Hill, NC (United States); Taylor, J.B. [University of North Carolina at Chapel Hill, Environment, Health and Safety, Chapel Hill, NC (United States)

    2017-05-15

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  15. Radiation dose associated with CT-guided drain placement for pediatric patients

    International Nuclear Information System (INIS)

    Schwartz, Cody J.; Isaacson, Ari J.; Fordham, Lynn Ansley; Ivanovic, Marija; Dixon, Robert G.; Taylor, J.B.

    2017-01-01

    To date, there are limited radiation dose data on CT-guided procedures in pediatric patients. Our goal was to quantify the radiation dose associated with pediatric CT-guided drain placement and follow-up drain evaluations in order to estimate effective dose. We searched the electronic medical record and picture archiving and communication system (PACS) to identify all pediatric (<18 years old) CT-guided drain placements performed between January 2008 and December 2013 at our institution. We compiled patient data and radiation dose information from CT-guided drain placements as well as pre-procedural diagnostic CTs and post-procedural follow-up fluoroscopic abscess catheter injections (sinograms). Then we converted dose-length product, fluoroscopy time and number of acquisitions to effective doses using Monte Carlo simulations and age-appropriate conversion factors based on annual quality-control testing. Fifty-two drainages were identified with mean patient age of 11.0 years (5 weeks to 17 years). Most children had diagnoses of appendicitis (n=23) or inflammatory bowel disease (n=11). Forty-seven patients had diagnostic CTs, with a mean effective dose of 7.3 mSv (range 1.1-25.5 mSv). Drains remained in place for an average of 16.9 days (range 0-75 days), with an average of 0.9 (0-5) sinograms per patient in follow-up. The mean effective dose for all drainages and follow-up exams was 5.3 mSv (0.7-17.1) and 62% (32/52) of the children had effective doses less than 5 mSv. The majority of pediatric patients who have undergone CT-guided drain placements at our institution have received total radiation doses on par with diagnostic ranges. This information could be useful when describing the dose of radiation to parents and providers when CT-guided drain placement is necessary. (orig.)

  16. Electronic Recruitment at CERN

    CERN Multimedia

    2004-01-01

    The Human Resources Department switches to electronic recruitment. From now on whenever you are involved in a recruitment action you will receive an e-mail giving you access to a Web folder. Inside you will find a shortlist of applications drawn up by the Human Resources Department. This will allow you to consult the folder, at the same time as everyone else involved in the recruitment process, for the vacancy you are interested in. This new electronic recruitment system, known as e-RT, will be introduced in a presentation given at 10 a.m. on 11 February in the Main Auditorium. Implemented by AIS (Administrative Information Services) and the Human Resources Department, e-RT will cover vacancies open in all of CERN's recruitment programmes. The electronic application system was initially made available to technical students in July 2003. By December it was extended to summer students, fellows, associates and Local Staff. Geraldine Ballet from the Recruitment Service prefers e-RT to mountains of paper! The Hu...

  17. CT in normal pressure hydrocephalus. Correlation between CT and clinical response to shunting

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K.; Nogaki, H.; Noda, M.; Kusunoki, T.; Tamaki, N. (Kobe Univ. (Japan). School of Medicine)

    1981-02-01

    CT scans were obtained on 33 patients (age 73y. to 31y.) with the diagnosis of normal pressure hydrocephalus. In each case, the diagnosis was made on the basis of the symptoms, CT and cisternographic findings. Underlying diseases of normal pressure hydrocephalus are ruptured aneurysms (21 cases), arteriovenous malformations (2 cases), head trauma (1 case), cerebrovascular accidents (1 case) and idiopathie (8 cases). Sixteen of 33 patients showed marked improvement, five, moderate or minimal improvement, and twelve, no change. The results were compared with CT findings and clinical response to shunting. CT findings were classified into five types, bases on the degree of periventricular hypodensity (P.V.H.), the extent of brain damage by underlying diseases, and the degree of cortical atrophy. In 17 cases of type (I), CT shows the presence of P.V.H. with or without minimal frontal lobe damage and no cortical atrophy. The good surgical improvements were achieved in all cases of type (I) by shunting. In 4 cases of type (II), CT shows the presence of P.V.H. and severe brain damage without cortical atrophy. The fair clinical improvements were achieved in 2 cases (50%) by shunting. In one case of type (III), CT shows the absence of P.V.H. without brain damage nor cortical atrophy. No clinical improvement was obtained by shunting in this type. In 9 cases of type (IV) with mild cortical atrophy, the fair clinical improvement was achieved in two cases (22%) and no improvement in 7 cases. In 2 cases of type (V) with moderate or marked cortical atrophy, no clinical improvement was obtained by shunting. In conclusion, it appeared from the present study that there was a good correlation between the result of shunting and the type of CT, and clinical response to shunting operation might be predicted by classification of CT findings.

  18. Estimation of skull table thickness with clinical CT and validation with microCT.

    Science.gov (United States)

    Lillie, Elizabeth M; Urban, Jillian E; Weaver, Ashley A; Powers, Alexander K; Stitzel, Joel D

    2015-01-01

    Brain injuries resulting from motor vehicle crashes (MVC) are extremely common yet the details of the mechanism of injury remain to be well characterized. Skull deformation is believed to be a contributing factor to some types of traumatic brain injury (TBI). Understanding biomechanical contributors to skull deformation would provide further insight into the mechanism of head injury resulting from blunt trauma. In particular, skull thickness is thought be a very important factor governing deformation of the skull and its propensity for fracture. Current computed tomography (CT) technology is limited in its ability to accurately measure cortical thickness using standard techniques. A method to evaluate cortical thickness using cortical density measured from CT data has been developed previously. This effort validates this technique for measurement of skull table thickness in clinical head CT scans using two postmortem human specimens. Bone samples were harvested from the skulls of two cadavers and scanned with microCT to evaluate the accuracy of the estimated cortical thickness measured from clinical CT. Clinical scans were collected at 0.488 and 0.625 mm in plane resolution with 0.625 mm thickness. The overall cortical thickness error was determined to be 0.078 ± 0.58 mm for cortical samples thinner than 4 mm. It was determined that 91.3% of these differences fell within the scanner resolution. Color maps of clinical CT thickness estimations are comparable to color maps of microCT thickness measurements, indicating good quantitative agreement. These data confirm that the cortical density algorithm successfully estimates skull table thickness from clinical CT scans. The application of this technique to clinical CT scans enables evaluation of cortical thickness in population-based studies. © 2014 Anatomical Society.

  19. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  20. Plastics disassembly versus bulk recycling: engineering design for end-of-life electronics resource recovery.

    Science.gov (United States)

    Rios, Pedro; Stuart, Julie Ann; Grant, Ed

    2003-12-01

    Annual plastic flows through the business and consumer electronics manufacturing supply chain include nearly 3 billion lb of high-value engineering plastics derived from petroleum. The recovery of resource value from this stream presents critical challenges in areas of materials identification and recycling process design that demand new green engineering technologies applied together with life cycle assessment and ecological supply chain analysis to create viable plastics-to-plastics supply cycles. The sustainable recovery of potentially high-value engineering plastics streams requires that recyclers either avoid mixing plastic parts or purify later by separating smaller plastic pieces created in volume reduction (shredding) steps. Identification and separation constitute significant barriers in the plastics-to-plastics recycling value proposition. In the present work, we develop a model that accepts randomly arriving electronic products to study scenarios by which a recycler might identify and separate high-value engineering plastics as well as metals. Using discrete eventsimulation,we compare current mixed plastics recovery with spectrochemical plastic resin identification and subsequent sorting. Our results show that limited disassembly with whole-part identification can produce substantial yields in separated streams of recovered engineering thermoplastics. We find that disassembly with identification does not constitute a bottleneck, but rather, with relatively few workers, can be configured to pull the process and thus decrease maximum staging space requirements.

  1. CT of splenic trauma

    International Nuclear Information System (INIS)

    Griffiths, B.G.; Federle, M.P.; Minagi, H.; Jeffrey, R.B.

    1986-01-01

    Fifty-five consecutive cases of surgically proved splenic injuries were evaluated by CT. CT correctly identified 54 splenic injuries, with one false-negative and three false-positive studies. In the single false-negative study and in two of the three false-positive studies, CT correctly indicated the presence of a large hemoperitoneum and other abdominal visceral lacerations and so correctly indicated the need for surgery. Of the 55 proved cases of splenic injury, CT revealed hemoperitoneum in 54 (99%), perisplenic clot in 47 (85%), splenic laceration in 39 (71%), and subcapsular hematoma in 13 (24%). Perisplenic clot can be distinguished from lysed blood in the peritoneal cavity and is a sensitive and specific sign of splenic trauma, even in the absence of visible splenic laceration. The authors conclude that CT is highly reliable means of evaluating splenic trauma

  2. Evaluation of pre and post-operative spinal plain CT and CT-myelography

    International Nuclear Information System (INIS)

    Nagase, Joji; Inoue, Shunichi; Miyasaka, Hitoshi; Kamata, Sakae; Shinohara, Hiroyasu.

    1983-01-01

    Confirmation of the level of scan slices is essential for the CT diagnosis of spinal and spinal-cord diseases. Pre- and postoperative comparison should be made on the same level. For reading of plain CT and CTM, window levels should be identical pre- and postoperatively. Both methods demonstrated the spinal canal, morphology of the spinal cord, and three-Fdimensional pathologic pictures inside and outside the spinal cord. Preoperative CT contributed useful information on the pathologic conditions and selection of surgical procedures and routes. Postoperative plain CT confirmed surgical results, and CTM revealed the spinal cord and the subarachnoid space, as well as the range and degree of decompression from the spinal cord. (Chiba, N.)

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... view of the body's interior. Refinements in detector technology allow new CT scanners to obtain multiple slices in a single rotation. These scanners, called "multislice CT" or "multidetector CT," ...

  4. Many-electron effect in the resonant Auger electron spectroscopy spectra of adsorbates

    International Nuclear Information System (INIS)

    Ohno, Masahide

    2007-01-01

    It is shown by a many-body theory that a resonantly excited core hole state in a chemisorbed molecule such as CO/Ni, CO/Pd, and CO/Pt relaxes to a fully relaxed one, i.e., the ionized core hole state of the smallest binding energy observed by photoelectron spectroscopy, before the core hole decays so that the resonant Auger electron spectroscopy (RAES) spectrum shows the normal Auger decay spectrum. It is shown by a many-body theory that the Auger peaks on the higher kinetic energy (K.E.) side in the RAES or AES spectrum, i.e., so called back-bonding peaks, are the two-hole states consisting of a valence hole and a hole in the adsorbate-substrate hybrid states below the substrate Fermi level. The latter hole is the change in the density of the hybrid states occupied by the screening electron from the core hole state to the valence-hole state. The difference between the back-bonding peak energy and the single valence-hole energy provides an important information about the change in the density of the hybrid states occupied by the screening electron from the core hole state to the valence-hole state. The difference between the RAES spectrum measured at the resonance energy and the AES spectrum measured at far above the ionization limit shows the competition between relaxation and decay of shakeup satellites such as the charge transfer (CT) shakeup. The relaxation rate of the CT shakeup state can be determined by Auger-photoelectron coincidence spectroscopy (APECS)

  5. SPECT/CT and pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Jann [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); The Faroese National Hospital, Department of Medicine, Torshavn (Faroe Islands); Gutte, Henrik [Copenhagen University Hospital, Department of Clinical Physiology, Nuclear Medicine and PET, Rigshospitalet, Copenhagen (Denmark); Herlev Hospital, Copenhagen University Hospital, Department of Radiology, Copenhagen (Denmark); University of Copenhagen, Cluster for Molecular Imaging, Faculty of Health Sciences, Copenhagen (Denmark)

    2014-05-15

    Acute pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/P) scintigraphy or pulmonary CT angiography (CTPA). In recent years both techniques have improved. Many nuclear medicine centres have adopted the single photon emission CT (SPECT) technique as opposed to the planar technique for diagnosing PE. SPECT has been shown to have fewer indeterminate results and a higher diagnostic value. The latest improvement is the combination of a low-dose CT scan with a V/P SPECT scan in a hybrid tomograph. In a study comparing CTPA, planar scintigraphy and SPECT alone, SPECT/CT had the best diagnostic accuracy for PE. In addition, recent developments in the CTPA technique have made it possible to image the pulmonary arteries of the lungs in one breath-hold. This development is based on the change from a single-detector to multidetector CT technology with an increase in volume coverage per rotation and faster rotation. Furthermore, the dual energy CT technique is a promising modality that can provide functional imaging in combination with anatomical information. Newer high-end CT scanners and SPECT systems are able to visualize smaller subsegmental emboli. However, consensus is lacking regarding the clinical impact and treatment. In the present review, SPECT and SPECT in combination with low-dose CT, CTPA and dual energy CT are discussed in the context of diagnosing PE. (orig.)

  6. Variation in quantitative CT air trapping in heavy smokers on repeat CT examinations

    Energy Technology Data Exchange (ETDEWEB)

    Mets, Onno M.; Gietema, Hester A.; Jong, Pim A. de [University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands); Isgum, Ivana; Mol, Christian P. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Zanen, Pieter [University Medical Center Utrecht, Pulmonology, Utrecht (Netherlands); Prokop, Mathias [Radboud University Nijmegen Medical Centre, Radiology, Nijmegen (Netherlands); University Medical Center Utrecht, Radiology, Heidelberglaan 100, Postbus 85500, Utrecht (Netherlands)

    2012-12-15

    To determine the variation in quantitative computed tomography (CT) measures of air trapping in low-dose chest CTs of heavy smokers. We analysed 45 subjects from a lung cancer screening trial, examined by CT twice within 3 months. Inspiratory and expiratory low-dose CT was obtained using breath hold instructions. CT air trapping was defined as the percentage of voxels in expiratory CT with an attenuation below -856 HU (EXP{sub -856}) and the expiratory to inspiratory ratio of mean lung density (E/I-ratio{sub MLD}). Variation was determined using limits of agreement, defined as 1.96 times the standard deviation of the mean difference. The effect of both lung volume correction and breath hold reproducibility was determined. The limits of agreement for uncorrected CT air trapping measurements were -15.0 to 11.7 % (EXP{sub -856}) and -9.8 to 8.0 % (E/I-ratio{sub MLD}). Good breath hold reproducibility significantly narrowed the limits for EXP{sub -856} (-10.7 to 7.5 %, P = 0.002), but not for E/I-ratio{sub MLD} (-9.2 to 7.9 %, P = 0.75). Statistical lung volume correction did not improve the limits for EXP{sub -856} (-12.5 to 8.8 %, P = 0.12) and E/I-ratio{sub MLD} (-7.5 to 5.8 %, P = 0.17). Quantitative air trapping measures on low-dose CT of heavy smokers show considerable variation on repeat CT examinations, regardless of lung volume correction or reproducible breath holds. (orig.)

  7. Clinical values of CT and dynamic CT in brain infarction

    International Nuclear Information System (INIS)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul

    1985-01-01

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre-and postcontrast CT

  8. Clinical values of CT and dynamic CT in brain infarction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Soo Il; Jang, Do; Seo, Eun Joo; Sohn, Myung Hee; Choi, Ki Chul [Chonbuk National University College of Medicine, Jeonju (Korea, Republic of)

    1985-04-15

    With the advent of faster scan time and new computer program, a scanning technique called 'dynamic computed tomography' has become possible. Dynamic computed tomography consisted of performing multiple rapid sequence scans after injection of contrast material. The authors have evaluated the clinical usefulness of computed tomography and dynamic computed tomography of 93 patients with brain infarction and/or ischemia during the period of 17 months from April 1983 to August 1984 in Department of Radiology, Chonbuk National University Hospital. The results were as follows; 1. The age distribution ranged from 18 years to 78 years. Among them the most common age group was between 50 years and 59 years (40.9%). 2. The sites of brain infarction were cerebral lobes (63 cases,68), basal ganglia (15 cases, 16.1%) and multiple sites (6 cases, 6.4%). The common affected site was middle cerebral artery territories. 3. The contrast enhancement of acute infarction was noted in 14 cases (17.5%) which occurred commonly between 3 days and 2 weeks from ictus. 4. The patterns of time-density curve in brain infarction and/or ischemia were as follow: a. Depression of slow wash-in phase was 20 cases (59%). b. Lower peak concentration was 17 cases (50%). c. Lower and delayed peak concentration was 7 cases (21%). d. No definite peak concentration was 6 cases (18%). First three patterns of time-density curve were thought as relatively characteristic curve of brain infarction and/or ischemia. 5. Two cases that showed negative findings on precontrast CT scan appeared to be positive findings as hypodensity on postcontrast CT scan and were confirmed as brain infarction by dynamic CT. 6. The diagnostic entity of dynamic CT scan were as follows; a. large artery thrombotic infarction were 23 cases (58%). b. lacnar infarction were 6 cases (15%). c. ischemia were 5 cases (13%). d. normal were 5 cases (13%). In six cases of lacunar infarction which was double hypodensity on pre

  9. Correction of CT artifacts and its influence on Monte Carlo dose calculations

    International Nuclear Information System (INIS)

    Bazalova, Magdalena; Beaulieu, Luc; Palefsky, Steven; Verhaegen, Frank

    2007-01-01

    Computed tomography (CT) images of patients having metallic implants or dental fillings exhibit severe streaking artifacts. These artifacts may disallow tumor and organ delineation and compromise dose calculation outcomes in radiotherapy. We used a sinogram interpolation metal streaking artifact correction algorithm on several phantoms of exact-known compositions and on a prostate patient with two hip prostheses. We compared original CT images and artifact-corrected images of both. To evaluate the effect of the artifact correction on dose calculations, we performed Monte Carlo dose calculation in the EGSnrc/DOSXYZnrc code. For the phantoms, we performed calculations in the exact geometry, in the original CT geometry and in the artifact-corrected geometry for photon and electron beams. The maximum errors in 6 MV photon beam dose calculation were found to exceed 25% in original CT images when the standard DOSXYZnrc/CTCREATE calibration is used but less than 2% in artifact-corrected images when an extended calibration is used. The extended calibration includes an extra calibration point for a metal. The patient dose volume histograms of a hypothetical target irradiated by five 18 MV photon beams in a hypothetical treatment differ significantly in the original CT geometry and in the artifact-corrected geometry. This was found to be mostly due to miss-assignment of tissue voxels to air due to metal artifacts. We also developed a simple Monte Carlo model for a CT scanner and we simulated the contribution of scatter and beam hardening to metal streaking artifacts. We found that whereas beam hardening has a minor effect on metal artifacts, scatter is an important cause of these artifacts

  10. CT findings at lupus mesenteric vasculitis

    International Nuclear Information System (INIS)

    Ko, S.F.; Lee, T.Y.; Cheng, T.T.; Ng, S.H.; Lai, H.M.; Cheng, Y.F.; Tsai, C.C.

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.)

  11. CT findings at lupus mesenteric vasculitis

    Energy Technology Data Exchange (ETDEWEB)

    Ko, S.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lee, T.Y. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Cheng, T.T. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Ng, S.H. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Lai, H.M. [Chang Gung Medical College and Memorial Hospital, Dept. of Rheumatology, Kaohsiung Hsien (Taiwan); Cheng, Y.F. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan); Tsai, C.C. [Chang Gung Medical College and Memorial Hospital, Dept. of Radiology, Kaohsiung Hsien (Taiwan)

    1997-01-01

    Purpose: To describe the spectrum of early CT findings of lupus mesenteric vasculitis (LMV) and to assess the utility of CT in the management of this uncommon entity. Methods: Abdominal CT was performed within 1-4 days (average 2.2 days) of the onset of severe abdominal pain and tenderness in 15 women with systemic lupus erythematosus. Prompt high-dose i.v. corticosteroid in 11 patients after the CT diagnosis of LMV was made. CT was performed after abdominal symptoms subsided. Results: Eleven cases revealed CT features suggestive of LMV including conspicuous prominence of mesentric vessels with palisade pattern or comb-like appearance (CT comb sign) supplying focal or diffuse dilated bowel loops (n=11), ascites with slightly increased peritoneal enhancement (n=11), small bowel wall thickening (n=10) with double halo or target sign (n=8). Follow-up CT before high-dose steroid therapy revealed complete or marked resolution of the abnormal CT findings. Conclusion: CT is helpful for confirming the diagnosis of LMV, especially the comb sign which may be an early sign. Bowel ischemia due to LMV is less ominous than previously expected, and the abnormal CT findings were reversible when early diagnosis and prompt i.v. steroid therapy could be achieved. (orig.).

  12. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  13. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    International Nuclear Information System (INIS)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo

    2016-01-01

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value

  14. CT, MRI, and FDG PET/CT findings of sinonasal sarcoma: Differentiation from squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Ho; Yoon, Dae Young; Baek, Sora; Park, Min Woo; Kwon, Kee Hwan; Rho, Young Soo [Kangdong Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-07-15

    To evaluate computed tomography (CT), magnetic resonance imaging (MRI), and 18F-fluorodeoxyglucose (FDG) positron emission tomography/CT (PET/CT) findings for the differentiation of sinonasal sarcoma from squamous cell carcinoma (SCC). We retrospectively reviewed CT, MRI, and FDG PET/CT results in 20 patients with pathologically proven sinonasal sarcoma (n = 7) and SCC (n = 13). Imaging characteristics of tumors, such as the shape, size, margin, MRI signal intensity, pattern of enhancement, local tumor invasion, and maximum standardized uptake value (SUVmax) were analyzed and compared between sarcoma and SCC. The SUVmax of sarcomas (7.4 ± 2.1) was significantly lower than the SUVmax of the SCCs (14.3 ± 4.5) (p = 0.0013). However, no significant difference in the shape, size, margin, MRI signal intensity, pattern of enhancement, and local tumor invasion was observed between sarcoma and SCC. Although CT and MR imaging features are nonspecific, FDG PET/CT is useful in distinguishing between sinonasal sarcoma and SCC based on the SUVmax value.

  15. Merge of terminological resources

    DEFF Research Database (Denmark)

    Henriksen, Lina; Braasch, Anna

    2012-01-01

    In our globalized world, the amount of cross-national communication increases rapidly, which also calls for easy access to multi-lingual high quality terminological resources. Sharing of terminology resources is currently becoming common practice, and efficient strategies for integration...... – or merging – of terminology resources are strongly needed. This paper discusses prerequisites for successful merging with the focus on identification of candidate duplicates of a subject domain found in the resources to be merged, and it describes automatic merging strategies to be applied to such duplicates...... in electronic terminology resources. Further, some perspectives of manual, supplementary assessment methods supporting the automatic procedures are sketched. Our considerations are primarily based on experience gained in the IATE and EuroTermBank projects, as merging was a much discussed issue in both projects....

  16. CT of hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, H; Tanaka, T; Sai, H; Kawamoto, S; Morimoto, K [Osaka Univ. (Japan). Faculty of Medicine

    1982-06-01

    CT was investigated in 125 cases of hepatocelluar carcinoma and 47 cases of metastatic hepatic neoplasm. The entire contour of each tumor was traced and the average CT value in the tumor was estimated. As a result, the CT value for hepatocellular carcinoma tended to be higher on plain CT and also after contrast enhancement. The CT findings seen frequently were as follows: capsule in 76 cases (60.8%) and septum in 67 cases (53.6%); tumor thrombus in portal vein in 39 cases (31.2%) and that in inferior vena cava in 3 cases (2.4%); localized enlargement of hepatic bile duct in 24 cases (19.2%). These findings were rarely seen in the cases of metastatic hepatic neoplasm. As a relatively outstanding feature of hepatic metastases, a double contour, like concentric circles or contour lines, with a relatively large inner circle or contour line, was found in 21 cases (44.7%). By paying attention to the change of CT value on contrast enhancement and the characteristic image of each case, hepatocellular carcinoma could be differentiated from metastatic hepatic neoplasm with high probability.

  17. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    It has been said that chronic subdural hematoma cannot be diagnosed by CT. In our cases, CT was used, and the results were described. According to the density of the picture, CT findings of chronic subdural hematoma could be classified into 3 types, those of higher density than that of the cerebral paranchyma, those of isodensity, and those of lower density than that of the cerebral parenchyma. The difference among them appeared to be due to variation in the fluid in hematoma, especially that in hemoglobin concentration. Chronic subdural hematoma was found in 27 of 388 cases of head trauma in which CT was undertaken in our department of surgery for last 2 years. It is difficult to differenciate this disease from subdural edema or subarachnoideal retention of the cerebrospinal fluid. In many cases, use of contrast medium added no change to the CT picture. Cerebral angiography is necessary for definite diagnosis of the disease. Chronic subdural hematoma gives more varieties of findings than other intracranial hematomas. However, if the film is very carefully read, CT is still useful for diagnosing this disease in spite of initially remarked difficulties. (Ueda, J.)

  18. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  19. CT-guided stereotactic neurosurgery

    International Nuclear Information System (INIS)

    Takizawa, Takaaki; Sato, Shoju; Matsumoto, Akira; Sano, Akira; Takahashi, Kazunori; Murakami, Yuji; Ohta, Kosuke

    1985-01-01

    Brown-Roberts-Wells stereotactic instruments were used for CT guided stereotactic surgery in 54 cases (65 operations). Stereotactic biopsy was done in 9 cases and successive regional chemotherapy was done in 3 cases. Stereotactic drainage was done in 2 cases of bacterial abcess, 3 cases of cystic neoplasm and 33 cases (43 operations) of intracerebral hematoma. CT guided stereotactic procedure was valuable for the correct cannulation to the center of the cavity. We tried to utilize CT image for the selection of targets for stereotactic functional neurosurgical procedures in 6 cases. In the cases of thalamotomy, the information derived from CT made the operation safer than that by contrast ventriculography alone. In all cases of electrode implantation for deep brain stimulation, accurate and precise electrode placement was achieved from CT images alone. This rapid and easy surgical technique was useful also for poor risk patients. (author)

  20. Integration of tools for binding archetypes to SNOMED CT.

    Science.gov (United States)

    Sundvall, Erik; Qamar, Rahil; Nyström, Mikael; Forss, Mattias; Petersson, Håkan; Karlsson, Daniel; Ahlfeldt, Hans; Rector, Alan

    2008-10-27

    The Archetype formalism and the associated Archetype Definition Language have been proposed as an ISO standard for specifying models of components of electronic healthcare records as a means of achieving interoperability between clinical systems. This paper presents an archetype editor with support for manual or semi-automatic creation of bindings between archetypes and terminology systems. Lexical and semantic methods are applied in order to obtain automatic mapping suggestions. Information visualisation methods are also used to assist the user in exploration and selection of mappings. An integrated tool for archetype authoring, semi-automatic SNOMED CT terminology binding assistance and terminology visualization was created and released as open source. Finding the right terms to bind is a difficult task but the effort to achieve terminology bindings may be reduced with the help of the described approach. The methods and tools presented are general, but here only bindings between SNOMED CT and archetypes based on the openEHR reference model are presented in detail.

  1. Thyroid lymphography-computed tomography (TLG-CT)

    International Nuclear Information System (INIS)

    Matsuyama, Koukichi

    1992-01-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author)

  2. CT scanning in pediatric head trauma: correlation of clinical features with CT scan diagnosis

    International Nuclear Information System (INIS)

    Arkoncel, Mary Ann P.; Posadas, Ma. Belen A.

    1997-01-01

    A retrospective review was conducted on 205 cases of pediatric head trauma for which cranial computed tomography scans were done at the Makati Medical Center, to determine which clinical features might positively predict an abnormality on CT scan. The clinical findings of loss of consciousness, GCS < 12, vomiting headache, seizures, and focal abnormalities on Neurologic Examination were significantly associated with abnormal findings on CT scan. However, a significant discrepancy does exist as to how accurately clinical findings do in fact predict normal and abnormal CT scan findings. Such a discrepancy allows us to conclude that a more liberal use of CT Scanning in cases of pediatric head trauma must be stressed to insure proper diagnosis. This study shows that when a patient presents with the aforementioned positive signs and symptoms, or with a focal neurologic deficit, or in combination, a 60-100 % positive prediction of abnormal CT Scan can be made. However, prediction of normal CT Scan is only 0-40%. (Author)

  3. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... or nurse at the time of the CT examination. If your child has a known contrast material ... be given to your child for the CT examination. top of page What does the CT equipment ...

  4. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  5. Complete electronics self-teaching guide with projects

    CERN Document Server

    Boysen, Earl

    2012-01-01

    An all-in-one resource on everything electronics-related! For almost 30 years, this book has been a classic text for electronics enthusiasts. Now completely updated for today's technology, this latest version combines concepts, self-tests, and hands-on projects to offer you a completely repackaged and revised resource. This unique self-teaching guide features easy-to-understand explanations that are presented in a user-friendly format to help you learn the essentials you need to work with electronic circuits. All you need is a general understanding of electronics concepts such as Oh

  6. CT diagnosis of acute spinal injury

    International Nuclear Information System (INIS)

    Ohhama, Mitsuru; Niimiya, Hikosuke; Kimura, Ko; Yamazaki, Gyoji; Nasu, Yoshiro; Shioya, Akihide

    1982-01-01

    CT pictures of 22 acute spinal injuries with damage of the spinal cord were evaluated. In the cases of spinal cord damage with bone injury, changes in the vertebral canal were fully observed by CT. In some of spinal cord damages without bone injury, narrowing of the vertebral canal was demonstrated by CT combined with CT myelography and reconstruction. Evaluation of CT number showed a high density area in damaged spinal cord in some cases. CT was thus considered to be useful as an adjunct diagnostic aid. (Ueda, J.)

  7. Positron emission tomography/computed tomography (PET/CT) and CT for N staging of non-small cell lung cancer.

    Science.gov (United States)

    Vegar Zubović, Sandra; Kristić, Spomenka; Hadžihasanović, Besima

    2017-08-01

    Aim The aim of this study is to investigate the possibilities of non-invasive diagnostic imaging methods, positron emission tomography/computed tomography (PET/CT) and CT, in clinical N staging of non-small cell lung cancer (NSCLC). Methods Retrospective clinical study included 50 patients with diagnosed NSCLC who have undergone PET/CT for the purpose of disease staging. The International association for the study of lung cancer (IASLC) nodal mapping system was used for analysis of nodal disease. Data regarding CT N-staging and PET/CT Nstaging were recorded. Two methods were compared using χ2 test and Spearman rank correlation coefficient. Results Statistical analysis showed that although there were some differences in determining the N stage between CT and PET/CT, these methods were in significant correlation. CT and PET/CT findings established the same N stage in 74% of the patients. In five patients based on PET/CT findings the staging was changed from operable to inoperable, while in four patients staging was changed from inoperable to operable. Conclusion PET/CT and CT are noninvasive methods that can be reliably used for N staging of NSCLC. Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

  8. The use of megavoltage CT (MVCT) images for dose recomputations

    International Nuclear Information System (INIS)

    Langen, K M; Meeks, S L; Poole, D O; Wagner, T H; Willoughby, T R; Kupelian, P A; Ruchala, K J; Haimerl, J; Olivera, G H

    2005-01-01

    Megavoltage CT (MVCT) images of patients are acquired daily on a helical tomotherapy unit (TomoTherapy, Inc., Madison, WI). While these images are used primarily for patient alignment, they can also be used to recalculate the treatment plan for the patient anatomy of the day. The use of MVCT images for dose computations requires a reliable CT number to electron density calibration curve. In this work, we tested the stability of the MVCT numbers by determining the variation of this calibration with spatial arrangement of the phantom, time and MVCT acquisition parameters. The two calibration curves that represent the largest variations were applied to six clinical MVCT images for recalculations to test for dosimetric uncertainties. Among the six cases tested, the largest difference in any of the dosimetric endpoints was 3.1% but more typically the dosimetric endpoints varied by less than 2%. Using an average CT to electron density calibration and a thorax phantom, a series of end-to-end tests were run. Using a rigid phantom, recalculated dose volume histograms (DVHs) were compared with plan DVHs. Using a deformed phantom, recalculated point dose variations were compared with measurements. The MVCT field of view is limited and the image space outside this field of view can be filled in with information from the planning kVCT. This merging technique was tested for a rigid phantom. Finally, the influence of the MVCT slice thickness on the dose recalculation was investigated. The dosimetric differences observed in all phantom tests were within the range of dosimetric uncertainties observed due to variations in the calibration curve. The use of MVCT images allows the assessment of daily dose distributions with an accuracy that is similar to that of the initial kVCT dose calculation

  9. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  10. Flat-detector computed tomography (FD-CT)

    International Nuclear Information System (INIS)

    Kalender, Willi A.; Kyriakou, Yiannis

    2007-01-01

    Flat-panel detectors or, synonymously, flat detectors (FDs) have been developed for use in radiography and fluoroscopy with the defined goal to replace standard X-ray film, film-screen combinations and image intensifiers by an advanced sensor system. FD technology in comparison to X-ray film and image intensifiers offers higher dynamic range, dose reduction, fast digital readout and the possibility for dynamic acquisitions of image series, yet keeping to a compact design. It appeared logical to employ FD designs also for computed tomography (CT) imaging. Respective efforts date back a few years only, but FD-CT has meanwhile become widely accepted for interventional and intra-operative imaging using C-arm systems. FD-CT provides a very efficient way of combining two-dimensional (2D) radiographic or fluoroscopic and 3D CT imaging. In addition, FD technology made its way into a number of dedicated CT scanner developments, such as scanners for the maxillo-facial region or for micro-CT applications. This review focuses on technical and performance issues of FD technology and its full range of applications for CT imaging. A comparison with standard clinical CT is of primary interest. It reveals that FD-CT provides higher spatial resolution, but encompasses a number of disadvantages, such as lower dose efficiency, smaller field of view and lower temporal resolution. FD-CT is not aimed at challenging standard clinical CT as regards to the typical diagnostic examinations; but it has already proven unique for a number of dedicated CT applications, offering distinct practical advantages, above all the availability of immediate CT imaging in the interventional suite or the operating room. (orig.)

  11. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  12. CT of abdominal abscesses

    International Nuclear Information System (INIS)

    Korobkin, M.T.

    1987-01-01

    The imaging search for a suspected abdominal abscess is common in hospitalized patients, especially after recent abdominal surgery. This paper examines the role of CT in the detection, localization, and treatment of abdominal abscess. The accuracy, limitations, and technical aspects of CT in this clinical setting are discussed. The diagnosis of an abscess is based on the demonstration of a circumscribed abnormal fluid collection. Although percutaneous aspiration with gram stain and culture is usually indicated to differentiate abscess from other fluid collections, the CT-based detection of extraluminal gas bubbles makes the diagnosis of an abscess highly likely. CT is compared with conventional radiographic studies, US, and radio-nuclide imaging. Specific CT and clinical features of abscesses in the following sites are emphasized: subphrenic space, liver, pancreas, kidneys, psoas muscle, appendix, and colonic diverticula. Most abdominal abscesses can be successfully treated with percutaneous drainage techniques. The techniques, results, and limitations of percutaneous abscess drainage are reviewed

  13. CT of tracheal agenesis

    International Nuclear Information System (INIS)

    Strouse, Peter J.; Hernandez, Ramiro J.; Newman, Beverley

    2006-01-01

    Tracheal agenesis is a rare and usually lethal anomaly. In the past, opaque contrast medium was injected via the esophagus to demonstrate the anatomy. To demonstrate the utility of helical and multidetector CT in delineating the aberrant anatomy in newborns with tracheal agenesis. Four newborns with tracheal agenesis were identified from three institutions. Imaging studies and medical records were reviewed. Each child was imaged with chest radiography. One child was imaged on a single-detector helical CT scanner and the other three on multidetector scanners. Helical and multidetector CT with 2D and 3D reconstructions clearly delineated the aberrant tracheobronchial and esophageal anatomy in each infant. Minimum intensity projection reformatted CT images were particularly helpful. One infant each had type I and type II tracheal agenesis. Two infants had type III tracheal agenesis. All four infants died. CT is a useful tool for delineating the aberrant anatomy of newborns with tracheal agenesis and thus helps in making rational clinical decisions. (orig.)

  14. Head trauma and CT

    International Nuclear Information System (INIS)

    Samejima, Kanji; Yoshii, Nobuo; Tobari, Chitoshi

    1979-01-01

    In our cases of acute and subacute subdural hematoma, the use of CT was evaluated. In our department of surgery, acute subdural hematoma was found in 46 of 388 patients of head trauma who underwent CT. Acute subdural hematoma, like epidural hematoma was usually visualized as a high-density area along the cranial inner table, and this was easily differenciated from epidural hematoma because of difference in shape from the other. The picture of acute subdural hematoma was occasionally confused with that of intracerebral hematoma or cerebral contusion. Single use of CT does not differenciate subacute subdural hematoma from chronic subdural hematoma. However, CT usually visualized acute hematoma as a high-density area, showing the extent of hematoma. Comparison of the thickness of hematoma with the axis deviation of the median part such as the 3rd cerebral ventricle suggested severity of cerebral edema. CT also revealed bilateral or multiple lesions of cerebral contusion or intracerebral hematoma. (Ueda, J.)

  15. CT of laryngeal trauma

    International Nuclear Information System (INIS)

    Jeffrey, R.B.

    1986-01-01

    Computed tomography has made a significant contribution to the radiologic assessment of the injured larynx. CT is an accurate, noninvasive modality that can rapidly diagnose both soft tissue and cartilaginous injuries. CT of the larynx involves a minimal degree of patient manipulation and discomfort and can be performed in conjunction with CT evaluation of intracranial or facial injuries. Conventional radiologic studies (anteroposterior and lateral soft tissue films of the neck, tomograms, or xerograms) are capable of demonstrating some cartilaginous fractures but are of limited value in defining the extent of soft tissue injury. In the acute trauma setting, laryngography is often technically difficult to perform because of patient discomfort and inability to cooperate. Although the overall experience is somewhat limited, CT appears to overcome many of the limitations of these conventional radiologic methods. The following is a discussion of the role of CT scanning in evaluating injuries to the larynx and cervical soft tissues

  16. Congenital bronchopulmonary malformation: CT histopathological correlation.

    Science.gov (United States)

    Kyncl, Martin; Koci, Martin; Ptackova, Lea; Hornofova, Ludmila; Ondrej, Fabian; Snajdauf, Jiri; Pychova, Marcela

    2016-12-01

    This study evaluated the accuracy of postnatal computed tomography (CT) imaging in the identification of congenital bronchopulmonary malformation (BPM) in comparison with histopathological analysis. CT scans of prenatally diagnosed BPMs from 24 patients with available histology were analysed retrospectively. The CT images were reviewed blinded to histological findings by two radiologists. Specific diagnosis was assigned based on predetermined criteria. The accuracy of CT was evaluated. The agreement rate in CT diagnosis between two radiologists was 100%. In 75% the lesions were located in the lower lobes. An overlap of 71% in CT and histopathological diagnoses was reached. The least matching diagnosis was type 2 CPAM. Contrast enhanced chest CT is very accurate in characterizing the BPM spectrum and provides important information on lesion type and structure.

  17. CT findings of inoperable lung carcinoma

    International Nuclear Information System (INIS)

    Gay, S.B.; Black, W.C.

    1987-01-01

    CT is useful in the evaluation of patients with newly diagnosed or highly suspected lung cancer. The principal role of CT is to screen those patients with metastatic disease beyond the hili from an attempt at curative thoracotomy. While CT is regarded as very sensitive, it is not considered highly specific, and thus a surgical procedure is usually recommended for definitive diagnosis of most ''positive'' CT findings. However, the authors demonstrate a few characteristic CT findings that are highly predictive of unresectable metastatic disease. These CT findings include massive mediastinal lymphadenopathy, diffuse mediastinal infiltration, pericardial involvement, vascular encasement, and advanced chest wall invasion

  18. Thyroid lymphography-computed tomography (TLG-CT)

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, Koukichi (Kansai Medical Univ., Moriguchi, Osaka (Japan))

    1992-10-01

    There are several useful diagnostic examinations for thyroid disease. The diagnostic value of CT in thyroid disease is still controvertial, although CT has become a routine clinical examination, since the plain CT does not always identify tumors accurately. In this paper, we introduce for the first time thyroid lymphography-computed tomography (TLG-CT) which may improve the diagnostic value of CT. The technique combines CT with thyroid lymphography. We performed TLG-CT in 92 patients with various thyroid diseases and 20 normal controls and classified the radiological features into the following 6 types: entire (normal thyroid); moth-eaten (Hashimoto's thyroiditis); defect (follicular adenoma and adenomatous goiter); lobate (papillary carcinoma); localized (various thyroid diseases); and extrathyroid defect (parathyroid tumor). In addition, we examined the relationship between TLG-CT type and the macroscopic appearance of the cut surface of the thyroid and lymph node metastasis in 20 patients with papillary carcinoma. The results suggest that papillary TLG-CT type carcinomas have a high incidence of lymph node metastasis. Our preliminary results suggest that TLG-CT is a potentially valuable diagnostic tool in the detection of thyroid disease and the assessment of the pathologic diagnosis as well as lymph node metastasis. (author).

  19. Oscillator clustering in a resource distribution chain

    DEFF Research Database (Denmark)

    Postnov, D.; Sosnovtseva, Olga; Mosekilde, Erik

    2005-01-01

    separate the inherent dynamics of the individual oscillator from the properties of the coupling network. Illustrated by examples from microbiological population dynamics, renal physiology, and electronic oscillator theory, we show how competition for primary resources in a resource distribution chain leads...

  20. CT diagnosis of hepatoma

    Energy Technology Data Exchange (ETDEWEB)

    Itai, Yuji [Tokyo Univ. (Japan). Faculty of Medicine

    1982-04-01

    In hepatocellular carcinoma, present status of CT diagnosis was discussed. Hepatocellular carcinoma is sometimes imaged in same concentration as that of surrounding tissues, and the detection rate ranged from 79 to 94%. The rate of differential diagnosis between primary and metastatic carcinoma was only 83% (includes 22% of false diagnosis) using contrast enhancement. The rates of detection of hepatocellular carcinoma and metastatic one were also only 87% and 75%, respectively, even by the combined use of arterial infusion CT and dynamic CT. However, the CT images is reproducible, and is supplemented by the information of US. Thus, the combination of these methods is useful in diagnosing the presence, extension, and nature of liver carcinoma.

  1. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... What is Children's CT? What are some common uses of the procedure? How should we prepare for the CT scan? What does the CT equipment look like? How does the procedure work? How is the procedure performed? What will my ...

  2. The role of CT in diagnosing small hepatic tumors; Usefulness of table incremental dynamic CT (ICT)

    Energy Technology Data Exchange (ETDEWEB)

    Usuki, Noriaki; Daikokuya, Hideo; Fukuda, Haruyuki; Saiwai, Shigeo; Nakajima, Hideyuki; Miyamoto, Takeshi; Kudo, Masatoshi (Kobe General Hospital, Hyogo (Japan))

    1992-11-01

    Twenty-seven cases of small hepatic tumors were examined by MRI and CT (ICT). MRI was more sensitive than plain and contrast CT. But ICT could detect more small lesions than MRI. CT is not more superior modality than MRI untill ICT is performed. It is concluded ICT should be done when diagnosing small hepatic tumors by CT. (author).

  3. CT of diffuse pulmonary diseases

    International Nuclear Information System (INIS)

    Itoh, Harumi; Murata, Kiyoshi; Todo, Giro

    1987-01-01

    While the theory of chest radiographic interpretation in diagnosing diffuse pulmonary diseases has not yet been established, X-ray computed tomography (CT), having intrinsic high contrast resolution and improved spatial resolution, has proved to offer important imformation concerning the location and invasion of diffuse pulmonary lesions. This study related to CT-pathologic correlation, focusing on perivascular interstitial space and secondary pulmonary lobule at macroscopic levels. The perivascular interstitial space was thickened as a result of the infiltration of cancer, granulomas, and inflammatory cells. This finding appeared as irregular contour of the blood vessel on CT. Centrilobular nodules were distributed at the tip of the bronchus or pulmonary artery on CT. The distance from the terminal and respiratory bronchioles to the lobular border was 2 to 3 mm. Lobular lesions were delineated as clear margin on CT. Contribution of these CT features to chest radiographic interpretation must await further studies. (Namekawa, K.)

  4. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark

    DEFF Research Database (Denmark)

    Hansen, David Christoffer; Seco, Joao; Sørensen, Thomas Sangild

    2015-01-01

    Background. Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in...... development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. Material and methods. A CT calibration phantom and an abdomen cross section...... phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling...

  5. A simulation study on proton computed tomography (CT) stopping power accuracy using dual energy CT scans as benchmark.

    Science.gov (United States)

    Hansen, David C; Seco, Joao; Sørensen, Thomas Sangild; Petersen, Jørgen Breede Baltzer; Wildberger, Joachim E; Verhaegen, Frank; Landry, Guillaume

    2015-01-01

    Accurate stopping power estimation is crucial for treatment planning in proton therapy, and the uncertainties in stopping power are currently the largest contributor to the employed dose margins. Dual energy x-ray computed tomography (CT) (clinically available) and proton CT (in development) have both been proposed as methods for obtaining patient stopping power maps. The purpose of this work was to assess the accuracy of proton CT using dual energy CT scans of phantoms to establish reference accuracy levels. A CT calibration phantom and an abdomen cross section phantom containing inserts were scanned with dual energy and single energy CT with a state-of-the-art dual energy CT scanner. Proton CT scans were simulated using Monte Carlo methods. The simulations followed the setup used in current prototype proton CT scanners and included realistic modeling of detectors and the corresponding noise characteristics. Stopping power maps were calculated for all three scans, and compared with the ground truth stopping power from the phantoms. Proton CT gave slightly better stopping power estimates than the dual energy CT method, with root mean square errors of 0.2% and 0.5% (for each phantom) compared to 0.5% and 0.9%. Single energy CT root mean square errors were 2.7% and 1.6%. Maximal errors for proton, dual energy and single energy CT were 0.51%, 1.7% and 7.4%, respectively. Better stopping power estimates could significantly reduce the range errors in proton therapy, but requires a large improvement in current methods which may be achievable with proton CT.

  6. Utility of Gallium-68 DOTANOC PET/CT in the localization of Tumour-induced osteomalacia.

    Science.gov (United States)

    Bhavani, Nisha; Reena Asirvatham, Adlyne; Kallur, Kumar; Menon, Arun S; Pavithran, Praveen V; Nair, Vasantha; Vasukutty, Jayakumar R; Menon, Usha; Kumar, Harish

    2016-01-01

    Tumour-induced osteomalacia (TIO) is a rare disorder characterized by hypophosphataemic osteomalacia caused by small mesenchymal tumours secreting fibroblast growth factor 23 (FGF 23). The most difficult part in the management of these patients is the localization of tumours causing TIO. We describe the utility of Gallium (Ga)-68 DOTANOC PET/CT in the localization of tumours causing TIO. The study was conducted in a single tertiary referral university teaching hospital in India. Ten patients with TIO who underwent Ga-68 DOTANOC PET/CT from the time period 2009 to 2014 were included in this study. Their detailed clinical history, biochemical parameters, imaging modalities, surgical interventions, histopathology and outcomes were reviewed. Ga-68 DOTANOC PET/CT could correctly localize the tumours in TIO in 9 of the 10 cases in which it was performed. Complete resection of the tumour led to full clinical recovery in six of the ten patients; two patients who had partial resection and one patient who underwent radiofrequency ablation showed partial remission. One patient in whom Ga-68 DOTANOC PET/CT was positive in vertebral body with a low standardized uptake value (SUV) did not show up the tumour on surgery. We conclude that Ga-68 DOTANOC PET/CT can be used as the first imaging modality in patients diagnosed with TIO. The extremely good outcome following the resection of these small otherwise undiagnosed tumours far outweighs its cost even in resource limited settings. © 2015 John Wiley & Sons Ltd.

  7. Super resolution reconstruction of μ-CT image of rock sample using neighbour embedding algorithm

    Science.gov (United States)

    Wang, Yuzhu; Rahman, Sheik S.; Arns, Christoph H.

    2018-03-01

    X-ray computed tomography (μ-CT) is considered to be the most effective way to obtain the inner structure of rock sample without destructions. However, its limited resolution hampers its ability to probe sub-micro structures which is critical for flow transportation of rock sample. In this study, we propose an innovative methodology to improve the resolution of μ-CT image using neighbour embedding algorithm where low frequency information is provided by μ-CT image itself while high frequency information is supplemented by high resolution scanning electron microscopy (SEM) image. In order to obtain prior for reconstruction, a large number of image patch pairs contain high- and low- image patches are extracted from the Gaussian image pyramid generated by SEM image. These image patch pairs contain abundant information about tomographic evolution of local porous structures under different resolution spaces. Relying on the assumption of self-similarity of porous structure, this prior information can be used to supervise the reconstruction of high resolution μ-CT image effectively. The experimental results show that the proposed method is able to achieve the state-of-the-art performance.

  8. The feasibility of surgical site tagging with CT virtual reality of the paranasal sinuses.

    Science.gov (United States)

    Hopper, K D; Iyriboz, A T; Wise, S W; Fornadley, J A

    1999-01-01

    The purpose of this work was to evaluate the feasibility of tagging (highlighting) surgical sites using volumetric CT virtual reality of the paranasal sinuses in the planning for endoscopic sinus surgery. Twenty-five patients with significant paranasal sinus disease had a planned surgical site marked on 2D coronal images. This planned surgical site was then tagged and included on CT volumetric virtual reality imaging. Each case was evaluated as to the ability of the CT virtual reality to demonstrate the planned surgical site and its orientation with respect to adjacent superficial anatomy. For all 25 planned surgeries, the virtual images showed the entire surgical site marked on the 2D coronal images. In all 25 cases, the orientation of the planned surgical site to adjacent normal anatomy was well demonstrated. For surgery into the maxillary sinuses, tagging and electronic removal of the middle turbinates and uncinate processes mimicked the actual surgery and allowed complete visualization of the infundibulum and the planned surgical site. Planned endoscopic paranasal sinus surgical sites can be easily and reliably highlighted using CT virtual reality techniques with respect to the patient's normal endoscopic anatomy.

  9. Acute pancreatitis: clinical vs. CT findings

    International Nuclear Information System (INIS)

    Hill, M.C.; Barkin, J.; Isikoff, M.B.; Silver stein, W.; Kalser, M.

    1982-01-01

    In a prospective study of 91 patients with acute pancreatitis, computed tomographic (CT) findings were correlated with the clinical type of acute pancreatitis. In acute edematous pancreatitis (63 patients; 16 with repeat CT), CT was normal (28%) or showed inflammation limited to the pancreas (61%). Phlegmonous changes were present in 11%, including one patient with focal pancreatic hemorrhage, indicating that clinically unsuspected hemorrhagic pancreatitis can occur. In acute necrotizing (hemorrhagic, suppurative) pancreatitis (nine patients; eight with repeat CT), no patient had a normal CT scan and 89% had phlegmonous changes. One patient had hemorrhagic pancreatitis and three had abscesses. In acute exacerbation of chronic pancreatitis (10 patients; three with repeat CT), there were pancreatic calcifications (70%), a focal mass (40%), and pancreatic ductal dilation (30%). On follow-up CT, the findings of acute pancreatitis did not always disappear with resolution of the clinical symptons. This was especialy true of phlegmonous pancreatitis, where the CT findings could persist for months

  10. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  11. CT examination of the kidneys

    International Nuclear Information System (INIS)

    Handa, Youji; Ishida, Ken; Arita, Takeshi; Ishine, Kenji; Tezen, Takashi; Ohta, Nobuhiro

    1985-01-01

    Plain CT scanning of the kidney was performed in 16 patients with renal failure whose basic renal disorder had been not necessarily known beforehand. The findings of the CT examination were composed of renal atrophy of various degree (12 cases), cystic lesions (8 cases), polycystic renal disease (one case), nephrosclerosis (2 cases), hydronephrosis (2 cases), ureter and renal stones (one case), and normal CT profile (2 cases). Being based on these CT findings and other clinical informations, basic renal disorders could be either presumed or confirmed. It was concluded that plain CT scanning of the kidney was useful to decide a method of treatment and to estimate prognosis in patients with renal failure. (author)

  12. Children's (Pediatric) CT (Computed Tomography)

    Medline Plus

    Full Text Available ... CT examinations are fast and simple; in emergency cases, they can reveal internal injuries and bleeding quickly enough to help save lives. CT has been shown to be a cost-effective imaging tool for a wide range of clinical problems. CT ...

  13. Do SNOMED CT Relationships Qualify?

    NARCIS (Netherlands)

    Cornet, Ronald

    2008-01-01

    An important feature of SNOMED CT is post-coordination, which is enabled as SNOMED CT specifies refinability of target concepts of relationships. In this paper the use of refinable relationships in SNOMED CT is analysed, and the interplay between refinable and defining relationships. Refinability is

  14. Optimization of CT image reconstruction algorithms for the lung tissue research consortium (LTRC)

    Science.gov (United States)

    McCollough, Cynthia; Zhang, Jie; Bruesewitz, Michael; Bartholmai, Brian

    2006-03-01

    To create a repository of clinical data, CT images and tissue samples and to more clearly understand the pathogenetic features of pulmonary fibrosis and emphysema, the National Heart, Lung, and Blood Institute (NHLBI) launched a cooperative effort known as the Lung Tissue Resource Consortium (LTRC). The CT images for the LTRC effort must contain accurate CT numbers in order to characterize tissues, and must have high-spatial resolution to show fine anatomic structures. This study was performed to optimize the CT image reconstruction algorithms to achieve these criteria. Quantitative analyses of phantom and clinical images were conducted. The ACR CT accreditation phantom containing five regions of distinct CT attenuations (CT numbers of approximately -1000 HU, -80 HU, 0 HU, 130 HU and 900 HU), and a high-contrast spatial resolution test pattern, was scanned using CT systems from two manufacturers (General Electric (GE) Healthcare and Siemens Medical Solutions). Phantom images were reconstructed using all relevant reconstruction algorithms. Mean CT numbers and image noise (standard deviation) were measured and compared for the five materials. Clinical high-resolution chest CT images acquired on a GE CT system for a patient with diffuse lung disease were reconstructed using BONE and STANDARD algorithms and evaluated by a thoracic radiologist in terms of image quality and disease extent. The clinical BONE images were processed with a 3 x 3 x 3 median filter to simulate a thicker slice reconstructed in smoother algorithms, which have traditionally been proven to provide an accurate estimation of emphysema extent in the lungs. Using a threshold technique, the volume of emphysema (defined as the percentage of lung voxels having a CT number lower than -950 HU) was computed for the STANDARD, BONE, and BONE filtered. The CT numbers measured in the ACR CT Phantom images were accurate for all reconstruction kernels for both manufacturers. As expected, visual evaluation of the

  15. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  16. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  17. {sup 18}F-FDG PET/CT and contrast-enhanced CT findings of pulmonary cryptococcosis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Si-yun, E-mail: wang_shuxia@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Chen, Gang, E-mail: cgggh@outlook.com [Department of Thoracic Surgery, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Luo, Dong-lan, E-mail: 695532870@qq.com [Department of Pathology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Shao, Dan, E-mail: shaodan501@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Liu, En-tao, E-mail: GDGH2015@gmail.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Sun, Taotao, E-mail: sunmoodsdaisy@bjmu.edu.cn [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China); Wang, Shu-Xia, E-mail: wsyggh@outlook.com [Department of PET Center, Guangdong General Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong (China)

    2017-04-15

    Purpose: Pulmonary cryptococcosis is an uncommon cause of pulmonary nodules in non-AIDS patients. This study reports the {sup 18}F-fluorodeoxyglucose-positron emission tomography ({sup 18}F-FDG PET/CT) and contrast-enhanced CT (CE-CT) findings of 42 patients with pulmonary cryptococcosis. Materials and methods: A retrospective review of the {sup 18}F-FDG PET/CT and CE-CT findings of 42 patients with histologically proven pulmonary cryptococcosis was conducted. All patients underwent PET/CT and CE-CT in the same session. The CT diagnosis was based on the location, morphological features, and enhancement of lesions. The PET/CT findings were recorded, and clinical data and surgical and histopathological findings were collected. Results: The results of the PET scans revealed that 37 (88%) of 42 patients showed higher FDG uptake, and 5 (12%) patients demonstrated lower FDG uptake than the mediastinal blood pool. The maximum standardized uptake value (SUV) of pulmonary cryptococcosis ranged from 1.4 to 13.0 (average: 5.7 ± 3.3, median 4.9). A single nodular pattern was the most prevalent pattern observed and was found in 29 (69%) patients. This pattern was followed by scattered nodular (n = 4, 10%), clustered nodular (n = 3, 7%), mass-like (n = 3, 7%), and bronchopneumonic (n = 3, 7%) patterns. The most frequent pattern of immunocompetent patients was the single nodular pattern (29 of 33, 88%). Immunocompromised patients most frequently pattern exhibited mass-like (3 of 9, 33%) and bronchopneumonic (3 of 9, 33%) patterns. Conclusion: Pulmonary cryptococcosis most commonly appears as single nodules in immunocompetent patients. Mass-like and bronchopneumonic patterns were common in immunocompromised patients. In 88% of patients, lung lesions showed high FDG uptake, thus mimicking a possible malignant condition.

  18. Post-ischemic bowel stricture: CT features in eight cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Sil [Dept. of Radiology, College of Medicine, Ewha Womans University, Mokdong Hospital, Seoul (Korea, Republic of); Kim, Hyun Jin; Hong, Sung Mo; Park, Seong Ho; Lee, Jong Seok; Kim, Ah Young; Ha, Hyun Kwon [University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    To investigate the characteristic radiologic features of post-ischemic stricture, which can then be implemented to differentiate that specific disease from other similar bowel diseases, with an emphasis on computed tomography (CT) features. Eight patients with a diagnosis of ischemic bowel disease, who were also diagnosed with post-ischemic stricture on the basis of clinical or pathologic findings, were included. Detailed clinical data was collected from the available electronic medical records. Two radiologists retrospectively reviewed all CT images. Pathologic findings were also analyzed. The mean interval between the diagnosis of ischemic bowel disease and stricture formation was 57 days. The severity of ischemic bowel disease was variable. Most post-ischemic strictures developed in the ileum (n = 5), followed by the colon (n = 2) and then the jejunum (n = 1). All colonic strictures developed in the “watershed zone.” The pathologic features of post-ischemic stricture were deep ulceration, submucosal/subserosal fibrosis and chronic transmural inflammation. The mean length of the post-ischemic stricture was 7.4 cm. All patients in this study possessed one single stricture. On contrast-enhanced CT, most strictures possessed concentric wall thickening (87.5%), with moderate enhancement (87.5%), mucosal enhancement (50%), or higher enhancement in portal phase than arterial phase (66.7%). Post-ischemic strictures develop in the ileum, jejunum and colon after an interval of several weeks. In the colonic segment, strictures mainly occur in the “watershed zone.” Typical CT findings include a single area of concentric wall thickening of medium length (mean, 7.4 cm), with moderate and higher enhancement in portal phase and vasa recta prominence.

  19. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  20. Early small-bowel ischemia: dual-energy CT improves conspicuity compared with conventional CT in a swine model.

    Science.gov (United States)

    Potretzke, Theodora A; Brace, Christopher L; Lubner, Meghan G; Sampson, Lisa A; Willey, Bridgett J; Lee, Fred T

    2015-04-01

    To compare dual-energy computed tomography (CT) with conventional CT for the detection of small-bowel ischemia in an experimental animal model. The study was approved by the animal care and use committee and was performed in accordance with the Guide for Care and Use of Laboratory Animals issued by the National Research Council. Ischemic bowel segments (n = 8) were created in swine (n = 4) by means of surgical occlusion of distal mesenteric arteries and veins. Contrast material-enhanced dual-energy CT and conventional single-energy CT (120 kVp) sequences were performed during the portal venous phase with a single-source fast-switching dual-energy CT scanner. Attenuation values and contrast-to-noise ratios of ischemic and perfused segments on iodine material-density, monospectral dual-energy CT (51 keV, 65 keV, and 70 keV), and conventional 120-kVp CT images were compared. Linear mixed-effects models were used for comparisons. The attenuation difference between ischemic and perfused segments was significantly greater on dual-energy 51-keV CT images than on conventional 120-kVp CT images (mean difference, 91.7 HU vs 47.6 HU; P conventional CT by increasing attenuation differences between ischemic and perfused segments on low-kiloelectron volt and iodine material density images. © RSNA, 2014.