  1. Comparison of polyp size and volume at CT colonography: implications for follow-up CT colonography.

    Science.gov (United States)

    Bethea, Emily; Nwawka, Ogonna K; Dachman, Abraham H

    2009-12-01

    The purpose of this study was to evaluate the reliability of polyp measurements at CT colonography and the factors that affect the measurements. Fifty colonoscopically proven cases of polyps 6 mm in diameter or larger were analyzed by two observers who measured each polyp in supine and prone views. Manual measurements of 2D volume by summation of areas, 2D maximum diameter, and 3D maximum diameter and automated measurements of 3D maximum diameter and volume were recorded for each observer and were repeated for one of the observers. Intraobserver and interobserver agreement was calculated. Analysis was performed to determine the measurement parameter that correlated most with summation-of-areas volume. Supine and prone measurements as a surrogate for tracking change in polyp size over time were analyzed to determine the measurement parameter with the least variation. Maximum diameter measured manually on 3D images had the highest correlation with summation-of-areas volume. Manual summation-of-areas volume was found to have the least variation between supine and prone measurements. Linear polyp measurement in the 3D endoluminal view appears to be the most reliable parameter for use in the decision to excise a polyp according to current guidelines. In our study, manual calculation of volume with summation of areas was found to be the most reliable measurement parameter for observing polyp growth over serial examinations. High reliability of polyp measurements is essential for adequate assessment of change in polyp size over serial examinations because many patients with intermediate-size polyps are expected to choose surveillance.

  2. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  3. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  4. CT- and MR colonography

    DEFF Research Database (Denmark)

    Achiam, Michael Patrick; Bülow, Steffen; Rosenberg, J

    2002-01-01

    BACKGROUND: Colorectal cancer is the second most frequent cancer and adenomas are widely accepted as precursors to colorectal cancer. Diagnosis and removal of adenomas are recommended to reduce cancer incidence and mortality. The current diagnostic methods include sigmoidoscopy and colonoscopy....... CONCLUSIONS: With the exponential development in computer processing power, CT- and MR colonography holds the promise for future colon examination with the advantages of non-invasiveness, no need for sedation, and probably no bowel preparation. A major disadvantage, however, is the radiation dose during CT...

  5. Bowel preparation for CT colonography

    International Nuclear Information System (INIS)

    Neri, Emanuele; Lefere, Philippe; Gryspeerdt, Stefaan; Bemi, Pietro; Mantarro, Annalisa; Bartolozzi, Carlo

    2013-01-01

    Bowel preparation represents an essential part of CT colonography, as the accuracy of the exam is strongly related to the adequacy of colonic cleansing, and a poor bowel preparation may compromise the diagnostic quality even despite optimization of all other acquisition parameters. Residual stool and fluid in the large bowel may affect the interpretation of the exam and may increase the number of false positives and false negatives. In this regard, the majority of patients having undergone CT colonography state that bowel preparation is the most unpleasant part. Unfortunately, to date no definite consensus has been reached about the ideal bowel preparation technique, and there is great variability in preparation strategies across diagnostic centers. The purpose of this review article is to describe the development and evolution of bowel preparation techniques in order to choose the best approach for optimizing the diagnostic quality of CT colonography in each patient

  6. Bowel preparation for CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Emanuele, E-mail: emanuele.neri@med.unipi.it [Diagnostic and Interventional Radiology, University of Pisa (Italy); Lefere, Philippe; Gryspeerdt, Stefaan [Department of Radiology, Stedelijk Ziekenhuis, Roeselare (Belgium); Bemi, Pietro; Mantarro, Annalisa; Bartolozzi, Carlo [Diagnostic and Interventional Radiology, University of Pisa (Italy)

    2013-08-15

    Bowel preparation represents an essential part of CT colonography, as the accuracy of the exam is strongly related to the adequacy of colonic cleansing, and a poor bowel preparation may compromise the diagnostic quality even despite optimization of all other acquisition parameters. Residual stool and fluid in the large bowel may affect the interpretation of the exam and may increase the number of false positives and false negatives. In this regard, the majority of patients having undergone CT colonography state that bowel preparation is the most unpleasant part. Unfortunately, to date no definite consensus has been reached about the ideal bowel preparation technique, and there is great variability in preparation strategies across diagnostic centers. The purpose of this review article is to describe the development and evolution of bowel preparation techniques in order to choose the best approach for optimizing the diagnostic quality of CT colonography in each patient.

  7. Bowel preparation for CT-colonography: Comparison of two different cleansing protocols

    International Nuclear Information System (INIS)

    Juchems, Markus S.; Hoffmann, Martin H.K.; Schmidt, Stefan A.; Apostel, Anna; Brambs, Hans-Juergen; Aschoff, Andrik J.

    2006-01-01

    Objective: Comparison of cleansing effects and colonic distension observed with two polyethyleneglycol-solution (PEG) containing bowel preparation techniques prior to CT-colonography (CTC). Materials and methods: One hundred and three patients that received CTC in our institution were retrospectively evaluated. Fifty-one patients received preparation 1 (BP1; based on a GoLytely formulation + bisacodyl), 52 preparation 2 (BP2; based on a NuLytely formulation + bisacodyl). On multi-planar-reformatted (MPR) images, fluid residuals and colon distension were assessed in five colonic segments, from the ascending colon to the rectum. Results: On average, significantly (p < 0.001) lower fluid residuals were assesses when using BP2 regardless of the patient position. In prone position, a significantly lower fluid level was observed in the sigmoid using bowel preparation 2. The average maximum diameter measured for the whole colon was 5.2 ± 0.6 cm in prone position and 4.8 ± 0.6 cm in the supine position in BP1 (p < 0.01). In BP2 the average maximum diameter measured for the whole colon was 5.3 ± 0.6 cm in prone position and 4.7 ± 0.5 cm in supine position, respectively (p < 0.001). Conclusion: Overall, lower fluid residuals were scored using BP2. In both preparation groups we achieved better colonic distension in prone position. We were not able to distend the sigmoid better when insufflating air during patient repositioning

  8. CT colonography: comparison of a colon dissection display versus 3D endoluminal view for the detection of polyps

    International Nuclear Information System (INIS)

    Juchems, Markus S.; Pauls, Sandra; Brambs, Hans-Juergen; Aschoff, Andrik J.; Fleiter, Thorsten R.; Schmidt, Stefan A.

    2006-01-01

    The purpose of this study was to compare sensitivity, specificity, and postprocessing time of a colon dissection approach to regular 3D-endoluminal workup of computed tomography (CT) colonography for the detection of polypoid lesions. Twenty-one patients who had received conventional colonoscopy after CT colonography were selected; 18 patients had either colon polyps or colon cancer and three had no findings. CT colonography was performed using a 4-channel multi-detector-row (MDR) CT in ten cases and a 16-channel MDR-CT in 11 cases. A blinded reader retrospectively evaluated all colonographies using both viewing methods in a randomized order. Thirty-seven polyps were identified by optical colonoscopy. An overall per-lesion sensitivity of 47.1% for lesions smaller than 5 mm, 56.3% for lesions between 5 mm and 10 mm, and 75.0% for lesion larger than 10 mm was calculated using the colon dissection approach. This compared to an overall per-lesion sensitivity of 35.3% ( 10 mm) using the endoluminal view. The average time consumption for CT colonography evaluation with the colon dissection software was 10 min versus 38 min using the endoluminal view. A colon dissection approach may provide a significant time advantage for evaluation of CT colonography while obtaining a high sensitivity. It is especially superior in the detection of lesions smaller than 5 mm. (orig.)

  9. Incidental physiological sliding hiatal hernia: a single center comparison study between CT with water enema and CT colonography.

    Science.gov (United States)

    Revelli, Matteo; Furnari, Manuele; Bacigalupo, Lorenzo; Paparo, Francesco; Astengo, Davide; Savarino, Edoardo; Rollandi, Gian Andrea

    2015-08-01

    Hiatal hernia is a well-known factor impacting on most mechanisms underlying gastroesophageal reflux, related with the risk of developing complications such as erosive esophagitis, Barrett's esophagus and ultimately, esophageal adenocarcinoma. It is our firm opinion that an erroneous reporting of hiatal hernia in CT exams performed with colonic distention may trigger a consecutive diagnostic process that is not only unnecessary, inducing a unmotivated anxiety in the patient, but also expensive and time-consuming for both the patient and the healthcare system. The purposes of our study were to determine whether colonic distention at CT with water enema and CT colonography can induce small sliding hiatal hernias and to detect whether hiatal hernias size modifications could be considered significant for both water and gas distention techniques. We retrospectively evaluated 400 consecutive patients, 200 undergoing CT-WE and 200 undergoing CTC, including 59 subjects who also underwent a routine abdominal CT evaluation on a different time, used as internal control, while a separate group of 200 consecutive patients who underwent abdominal CT evaluation was used as external control. Two abdominal radiologists assessed the CT exams for the presence of a sliding hiatal hernia, grading the size as small, moderate, or large; the internal control groups were directly compared with the corresponding CT-WE or CTC study looking for a change in hernia size. We used the Student's t test applying a size-specific correction factor, in order to account for the effect of colonic distention: these "corrected" values were then individually compared with the external control group. A sliding hiatal hernia was present in 51 % (102/200) of the CT-WE patients and in 48.5 % (97/200) of the CTC patients. Internal control CT of the 31 patients with a hernia at CT-WE showed resolution of the hernia in 58.1 % (18/31) of patients, including 76.5 % (13/17) and 45.5 % (5/11) of small and moderate

  10. Essential requirements of a CT colonography service

    International Nuclear Information System (INIS)

    Hansmann, Anika; Burling, David

    2013-01-01

    There are many potential challenges to developing a high quality, efficient CT colonography service. Some are clear and predictable, for example creating CT capacity and securing financial resources, but some are less obvious, such as harnessing local support or changing referral practice amongst clinical colleagues. Notwithstanding, such barriers will need to be overcome to deliver a well-resourced, successful CT colonography programme. This article utilises the authors’ experience of developing their own CT colonography service from scratch (now examining >1200 patients per annum) and relevant published articles on ‘Standards’ of practice and training to recommend how others might provide CT colonography in their own patient communities. We offer a practical guide and will emphasise the need for a multi-disciplinary approach with locally agreed protocols and service objectives

  11. CT colonography: Techniques, indications, findings

    International Nuclear Information System (INIS)

    Mang, Thomas; Graser, Anno; Schima, Wolfgang; Maier, Andrea

    2007-01-01

    Computed tomographic colonography (CTC) is a minimally invasive technique for imaging the entire colon. Based on a helical thin-section CT of the cleansed and air-distended colon, two-dimensional and three-dimensional projections are used for image interpretation. Several clinical improvements in patient preparation, technical advances in CT, and new developments in evaluation software have allowed CTC to develop into a powerful diagnostic tool. It is already well established as a reliable diagnostic tool in symptomatic patients. Many experts currently consider CTC a comparable alternative to conventional colonoscopy, although there is still debate about its sensitivity for the detection of colonic polyps in a screening population. This article summarizes the main indications, the current techniques in patient preparation, data acquisition and data analysis as well as imaging features for common benign and malignant colorectal lesions

  12. A comparison of primary two- and three-dimensional methods to review CT colonography

    International Nuclear Information System (INIS)

    Gelder, Rogier E. van; Florie, Jasper; Nio, C. Yung; Jager, Steven W. de; Lameris, Johan S.; Stoker, Jaap; Jensch, Sebastiaan; Vos, Frans M.; Venema, Henk W.; Bartelsman, Joep F.; Reitsma, Johannes B.; Bossuyt, Patrick M.M.

    2007-01-01

    The aim of our study was to compare primary three-dimensional (3D) and primary two-dimensional (2D) review methods for CT colonography with regard to polyp detection and perceptive errors. CT colonography studies of 77 patients were read twice by three reviewers, first with a primary 3D method and then with a primary 2D method. Mean numbers of true and false positives, patient sensitivity and specificity and perceptive errors were calculated with colonoscopy as a reference standard. A perceptive error was made if a polyp was not detected by all reviewers. Mean sensitivity for large (≥10 mm) polyps for primary 3D and 2D review was 81% (14.7/18) and 70%(12.7/18), respectively (p-values ≥0.25). Mean numbers of large false positives for primary 3D and 2D were 8.3 and 5.3, respectively. With primary 3D and 2D review 1 and 6 perceptive errors, respectively, were made in 18 large polyps (p = 0.06). For medium-sized (6-9 mm) polyps these values were for primary 3D and 2D, respectively: mean sensitivity: 67%(11.3/17) and 61%(10.3/17; p-values≥ 0.45), number of false positives: 33.3 and 15.6, and perceptive errors: 4 and 6 (p = 0.53). No significant differences were found in the detection of large and medium-sized polyps between primary 3D and 2D review. (orig.)

  13. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Takashi; Urata, Joji [Diagnostic Imaging Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Mitsuzaki, Katsuhiko; Matsuda, Katsuhiko; Kawakami, Megumi [Medical Examination Center, Saiseikai Kumamoto Hospital, Kumamoto (Japan); Utsunomiya, Daisuke; Yamamura, Sadahiro; Yamashita, Yasuyuki [Diagnostic Radiology, Faculty of Life Sciences, Kumamoto Univ., Kumamoto (Japan)], e-mail: utsunomi@kumamoto-u.ac.jp

    2012-09-15

    Background: Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. Purpose: To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. Material and Methods: We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Results: Detection sensitivity for flat polyps was 31.3 %, 44.4 %, and 87.5 % for lesions measuring 2-3 mm, 4-5 mm, and {>=}6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6 %, 79.0 %, and 91.7 %. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. Conclusion: CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  14. Clinical application of helical CT colonography

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Rujian; Liang Jianhao; Ou Weiqian; Wen Haomao

    2009-01-01

    Objective: To investigate the clinical value of 16-slice helical CT colonography in the diagnosis of colon tumor and polypus. Methods: 16-slice helical CT volumetric scanning was performed in 18 patients with colonic disease, including colonic tumor (n=16) and colonic polypus (n=2). 3D images, virtual endoscopy and multiplanar reformation were obtained in the AW4.1 workstation. CT appearances were compared with operation and fiberoptic colonoscopy. Results: Satisfied results were achieved from 18 patients, no difference found in results between CT colonography and operation in 16 patients with colonic tumor. Conclusion: 16-slice helical CT colonography is of great value in preoperative staging of colonic tumor and have a high value in clinical application. (authors)

  15. Spiral CT colonography in inflammatory bowel disease

    International Nuclear Information System (INIS)

    Tarjan, Zsolt; Zagoni, Tamas; Gyoerke, Tamas; Mester, Adam; Karlinger, Kinga; Mako, Erno K.

    2000-01-01

    Objective: Most of the studies on virtual colonoscopy are dealing with the role of detecting colorectal polyps or neoplasms. We have undertaken this study to evaluate the value of CT colonography in patients with colonic Crohn's disease. Methods and material: Five patients (three males, two females, 23-51 years, mean age 42 years) with known (4) or suspected (1) Crohn's disease of the colon underwent fiberoptic colonoscopy and CT colonography in the same day or during a 1-week period. The images were evaluated with the so called zoomed axial slice movie technique and in some regions intra- and extraluminal surface shaded and volume rendered images were generated on a separate workstation. The results were compared to those of a colonoscopy. Results: The final diagnosis was Crohn's disease in four patients and colitis ulcerosa in one. Total examination was possible by colonoscopy in two cases, and with CT colonography in all five cases. The wall of those segments severely affected by the disease were depicted by the axial CT scans to be thickened. The thick walled, segments with narrow lumen seen on CT colonography corresponded to the regions where colonoscopy was failed to pass. Air filled sinus tracts, thickening of the wall of the terminal ileum, loss of haustration pseudopolyps and deep ulcers were seen in CT colonography. Three dimensional (3D) endoluminal views demonstrated pseudopolyps similar to endoscopic images None of the colonoscopically reported shallow ulcerations or aphtoid ulcerations or granular mucosal surface were observed on 2- or 3D CT colonographic images. Conclusion: CT colonography by depicting colonic wall thickening seems to be a useful tool in the diagnosis of Crohn's colitis, which could be a single examination depicting the intraluminal, and transmural extent of the disease

  16. Clinical study of CT colonography

    International Nuclear Information System (INIS)

    Nakazawa, Saburo; Hattori, Toshiyuki; Inui, Kazuo

    2011-01-01

    We studied the usefulness of CT colonography (CTC) for colon cancer diagnosis. CTC and optical colonoscopy were performed for 150 cases mainly including patients with a positive fecal occult blood test (FOBT). The results were compared and analyzed. The following are the final diagnoses given to the patients: advanced colon cancer: 41 cases; early cancer: 25 cases; adenoma: 74 cases; hyperplasia: 3 cases; submucosal tumor: 1 case; and no lesion: 6 cases. In terms of diagnostic performance of CTC, accuracy was found to be 96%, sensitivity was found to be 97.9%, and specificity was found to be 50%. Cancer stage-specific sensitivity was as follows: advanced colon cancer: 100%; early cancer: 96.3%; adenoma: 71.2%; and hyperplasia: 47.4%. Lesion site-specific sensitivity was as follows: caecum: 76.2%; ascending colon: 57.6%; transverse colon: 66.2%; descending colon: 83.3%; sigmoid colon: 85.1%; and rectum: 78.0%. Lesion size-specific sensitivity was as follows: 2 to 5 mm: 56.7%; 6 to 9 mm: 88.1%; 10 mm or more: 92.5%; and 6 mm or more: 90.9%. Therefore, the diagnostic sensitivity of CTC was confirmed to be high. The results suggest that CTC would be useful for colon cancer screening. (author)

  17. CT colonography: effect of experience and training on reader performance

    International Nuclear Information System (INIS)

    Taylor, Stuart A.; Burling, David; Morley, Simon; Bartram, Clive I.; Halligan, Steve; Bassett, Paul; Atkin, Wendy

    2004-01-01

    The purpose of this paper was to investigate the effect of radiologist experience and increasing exposure to CT colonography on reader performance. Three radiologists of differing general experience (consultant, research fellow, trainee) independently analysed 100 CT colonographic datasets. Readers had no prior experience of CT colonography and received feedback and training after the first 50 cases from an independent experienced radiologist. Diagnostic performance and reporting times were compared for the first and second 50 datasets and compared with the results of a radiologist experienced in CT colonography. Before training only the consultant reader achieved statistical equivalence with the reference standard for detection of larger polyps. After training, detection rates ranged between 25 and 58% for larger polyps. Only the trainee significantly improved after training (P=0.007), with performance of other readers unchanged or even worse. Reporting times following training were reduced significantly for the consultant and fellow (P<0.001 and P=0.03, respectively), but increased for the trainee (P<0.001). In comparison to the consultant reader, the odds of detection of larger polyps was 0.36 (CI 0.16, 0.82) for the fellow and 0.36 (CI 0.14, 0.91) for the trainee. There is considerable variation in the ability to report CT colonography. Prior experience in gastrointestinal radiology is a distinct advantage. Competence cannot be assumed even after directed training via a database of 50 cases. (orig.)

  18. CT colonography in faecal occult blood test positives

    NARCIS (Netherlands)

    Liedenbaum, M.H.

    2010-01-01

    CT colonography is a non-invasive imaging technique to visualise the colon. The colon is insufflated with CO2 or air and a CT-scan of the abdomen is performed. The performance of CT colonography is nearly equal to that of colonoscopy in the detection of large colonic polyps and carcinomas. This

  19. National survey of CT colonography practice in Ireland

    LENUS (Irish Health Repository)

    Smyth, A.E.

    2016-06-01

    CT Colonography was first introduced to Ireland in 1999. Our aim of this study is to review current CT Colonography practices in the Republic of Ireland. A questionnaire on CT Colonography practice was sent to all non-maternity adult radiology departments in the Republic of Ireland with a CT scanner. The results are interpreted in the context of the recommendations on CT Colonography quality standards as published by the European Society of Gastrointestinal and Abdominal Radiology (ESGAR) consensus statement in the journal of European Radiology in 2013. Thirty centres provide CT Colonography; 21 of which responded (70%). Each centre performs median 90 studies per year; the majority follow accepted patient preparation and image acquisition protocols. Seventy-six percent of the centres repsonded that the majority of patients imaged are symptomatic. Of the 51 consultant radiologists reading CT Colonography, 37 (73%) have attended a CT Colonography course. In 17 (81%) of the centres the studies are single read although 81% of the centres have access to a second radiologist’s opinion. Fourteen (67%) of the centres reported limited access to CT scanner time as the major limiting factor to expanding their service. CT Colonography is widely

  20. CT colonography and cost-effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Mavranezouli, Ifigeneia [University College London, National Collaborating Centre for Mental Health, Centre for Outcomes Research and Effectiveness, Sub-department of Clinical Health Psychology, London (United Kingdom); East, James E. [St Marks Hospital, Imperial College London, Wolfson Unit for Endoscopy, London (United Kingdom); Taylor, Stuart A. [University College Hospital, Specialist X-Ray, London (United Kingdom); University College Hospital, Department of Imaging, London (United Kingdom)

    2008-11-15

    CT colonography (CTC) is increasingly advocated as an effective initial screening tool for colorectal cancer. Nowadays, policy-makers are increasingly interested in cost-effectiveness issues. A number of studies assessing the cost-effectiveness of CTC have been published to date. The majority of findings indicate that CTC is probably not cost-effective when colonoscopy is available, but this conclusion is sensitive to a number of key parameters. This review discusses the findings of these studies, and considers those factors which most influence final conclusions, notably intervention costs, compliance rates, effectiveness of colonoscopy, and the assumed prevalence and natural history of diminutive advanced polyps. (orig.)

  1. CT colonography and cost-effectiveness

    International Nuclear Information System (INIS)

    Mavranezouli, Ifigeneia; East, James E.; Taylor, Stuart A.

    2008-01-01

    CT colonography (CTC) is increasingly advocated as an effective initial screening tool for colorectal cancer. Nowadays, policy-makers are increasingly interested in cost-effectiveness issues. A number of studies assessing the cost-effectiveness of CTC have been published to date. The majority of findings indicate that CTC is probably not cost-effective when colonoscopy is available, but this conclusion is sensitive to a number of key parameters. This review discusses the findings of these studies, and considers those factors which most influence final conclusions, notably intervention costs, compliance rates, effectiveness of colonoscopy, and the assumed prevalence and natural history of diminutive advanced polyps. (orig.)

  2. Pitfalls in multidetector row CT colonography

    International Nuclear Information System (INIS)

    Stoyneva, V.

    2009-01-01

    Full text:MDCT colonography is a reliable method for detection and identification of type of the colon lesions. At every step of the examination an error could be made and that would be lead to an incorrect diagnosis. Problems and pitfalls can be overcome with various useful techniques. The relatively clean and dry colon after careful preparation, allows avoiding problems of residual fluid and faeces. The knowledge about the structure and thickness characteristics of lesions of the colon and artefacts can to be useful in distinction of the polypoidal lesions from normal findings. The aim of this lecture is to describe common and less common pitfalls in CT colonography and to clarify features and CT criteria to distinction of organic formations from pseudo lesions. Inadequate preparation of the patient, weaknesses into the protocol, gaps and errors in interpretation are responsible for false positive and false negative results. The training which reduces the residual solids and liquid, marking, protocols elaboration and CAD allows achieving higher sensitivity and specificity. The 2D and 3D application techniques and solid knowledge about CT characteristic of the colon organic findings and pseudo lesions will reduce the rate of false positive results

  3. Bowel wall visualisation at CT colonography

    International Nuclear Information System (INIS)

    Svensson, M.H.; Hellstroem, M.; Svensson, E.

    2002-01-01

    Purpose: To evaluate the quality of bowel wall visualisation at CT colonography and the impact of examination in the supine and prone positions. Material and Methods: After bowel preparation, 111 patients underwent CT colonography. Air distension, degree of fluid redistribution with change in body position (supine and prone), influence of residual stool on bowel wall assessability, and quality of overall colon visualisation were evaluated using scales. Results: Thirty of 110 patients (27%) had complete overall visualisation of the colon wall and 52 (47%) had subtotal visualisation of a limited part of the colon. The entire colon was more often air-filled in the prone position (46%) than in the supine position (18%). Joint review of supine and prone data showed that for all colon segments, except the sigmoid (86%), 95% of the patients had complete air filling. All patients had residual fluid. In 75% to 99%, depending on segment, fluid did not interfere with the bowel wall visualisation in the combined evaluation of supine and prone data sets. Thirty-one patients had residual stool with potential negative influence on polyp detection. Conclusions: The colon wall was completely, or almost completely, visualised in 75% of the patients, and examination in the supine and prone positions was necessary for complete visualisation

  4. CT colonography versus double-contrast barium enema for screening of colorectal cancer: comparison of radiation burden.

    Science.gov (United States)

    Neri, Emanuele; Faggioni, Lorenzo; Cerri, Francesca; Turini, Francesca; Angeli, Simone; Cini, Lorenzo; Perrone, Franco; Paolicchi, Fabio; Bartolozzi, Carlo

    2010-10-01

    Our aim is to compare the radiation dose associated with a low-dose CT colonography (CTC) protocol for colorectal cancer screening with that delivered by double-contrast barium enema (DCBE). CTC of twenty asymptomatic individuals (M:F = 10:10) participating to a colorectal cancer screening program and DCBE of fifteen patients (M:F = 6:9) were evaluated. For CTC, absorbed dose was determined by calculating the dose-length product for each CTC examination from measurements on a CT dose phantom equipped with a CT ion chamber. For DCBE, the free-in-air Kerma at the patient's X-ray entry surface and the Kerma-area product during fluoroscopy and fluorography were measured with a Barracuda system, with fluoroscopy times being recorded blinded to the performing operator. Effective dose at CTC was 2.17 ± 0.12 mSv, with good and excellent image quality in 14/20 (70%) and 6/20 cases (30%), respectively. With DCBE, effective patient dose was 4.12 ± 0.17 mSv, 1.9 times greater than CTC (P < 0.0001). Our results show that effective dose from screening CTC is substantially lower than that from DCBE, suggesting that CTC is the radiological imaging technique of the large bowel with the lowest risk of stochastic radiation effects.

  5. Comparison of a 4-Day versus 2-Day Low Fiber Diet Regimen in Barium Tagging CT Colonography in Incomplete Colonoscopy Patients

    Directory of Open Access Journals (Sweden)

    Kaan Meric

    2015-01-01

    Full Text Available Our aim was to compare the amount of residual feces, residual fluid, the tagging quality, and patient compliance using 4-day versus 2-day low fiber diet regimen in barium tagging CT colonography in incomplete colonoscopy patients. Methods. A total of 101 patients who underwent CT colonography were assigned to 2-day diet group (n=56 and 4-day diet group (n=45. Fecal tagging was achieved with barium sulphate while bisacodyl and sennoside B were used for bowel preparation. Residual solid stool was divided into two groups measuring 0.05. The prevalence of moderate discomfort was significantly higher in 4-day group (P<0.001. Conclusion. Our study shows that 2-day limited bowel preparation regimen for fecal tag CT colonography is a safe and reasonable technique to evaluate the entire colon, particularly in incomplete conventional colonoscopy patients.

  6. Reducing image noise in computed tomography (CT) colonography: effect of an integrated circuit CT detector.

    Science.gov (United States)

    Liu, Yu; Leng, Shuai; Michalak, Gregory J; Vrieze, Thomas J; Duan, Xinhui; Qu, Mingliang; Shiung, Maria M; McCollough, Cynthia H; Fletcher, Joel G

    2014-01-01

    To investigate whether the integrated circuit (IC) detector results in reduced noise in computed tomography (CT) colonography (CTC). Three hundred sixty-six consecutive patients underwent clinically indicated CTC using the same CT scanner system, except for a difference in CT detectors (IC or conventional). Image noise, patient size, and scanner radiation output (volume CT dose index) were quantitatively compared between patient cohorts using each detector system, with separate comparisons for the abdomen and pelvis. For the abdomen and pelvis, despite significantly larger patient sizes in the IC detector cohort (both P 0.18). Based on the observed image noise reduction, radiation dose could alternatively be reduced by approximately 20% to result in similar levels of image noise. Computed tomography colonography images acquired using the IC detector had significantly lower noise than images acquired using the conventional detector. This noise reduction can permit further radiation dose reduction in CTC.

  7. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... is used to screen the large intestine or colon for cancer and growths called polyps. This procedure uses low-dose CT or CAT scanning to produce pictures of the colon and the rectum. During the examination, a small ...

  8. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... commonly known, virtual colonoscopy. Virtual colonoscopy is a diagnostic imaging test that is used to screen the large intestine or colon for cancer and growths called polyps. This procedure uses low-dose CT or CAT scanning ... Disorders Video: The Basketball Game: An ...

  9. Comparison between CT Colonography and Double-Contrast Barium Enema for Colonic Evaluation in Patients with Renal Insufficiency

    International Nuclear Information System (INIS)

    Chung, Sun Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su Ki; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  10. Comparison between CT colonography and double-contrast barium enema for colonic evaluation in patients with renal insufficiency.

    Science.gov (United States)

    Chung, Sun-Young; Park, Seong Ho; Lee, Seung Soo; Lee, Ju Hee; Kim, Ah Young; Park, Su-Kil; Han, Duck Jong; Ha, Hyun Kwon

    2012-01-01

    To compare the CT colonography (CTC) and double-contrast barium enema (DCBE) for colonic evaluation in patients with renal insufficiency. Two sequential groups of consecutive patients with renal insufficiency who had a similar risk for colorectal cancer, were examined by DCBE (n = 182; mean ± SD in age, 51 ± 6.4 years) and CTC (n = 176; 50 ± 6.7 years), respectively. CTC was performed after colon cleansing with 250-mL magnesium citrate (n = 87) or 4-L polyethylene glycol (n = 89) and fecal tagging. DCBE was performed after preparation with 250-mL magnesium citrate. Patients with colonic polyps/masses of ≥ 6 mm were subsequently recommended to undergo a colonoscopy. Diagnostic yield and positive predictive value (PPV) for colonic polyps/masses, examination quality, and examination-related serum electrolyte change were retrospectively compared between the two groups. Both the CTC and DCBE were positive for colonic polyps/masses in 28 (16%) of 176 and 11 (6%) of 182 patients, respectively (p = 0.004). Among patients with positive findings, 17 CTC and six DCBE patients subsequently underwent a colonoscopy and yielded a PPV of 88% (15 of 17 patients) and 50% (3 of 6 patients), respectively (p = 0.089). Thirteen patients with adenomatous lesions were detected in the CTC group (adenocarcinoma [n = 1], advanced adenoma [n = 6], and non-advanced adenoma [n = 6]), as compared with two patients (each with adenocarcinoma and advanced adenoma) in the DCBE group (p = 0.003). Six (3%) of 176 CTC and 16 (9%) of 182 DCBE examinations deemed to be inadequate (p = 0.046). Electrolyte changes were similar in the two groups. In patients with renal insufficiency, CTC has a higher diagnostic yield and a marginally higher PPV for detecting colorectal neoplasia, despite a similar diagnostic yield for adenocarcinoma, and a lower rate of inadequate examinations as compared with DCBE.

  11. Colonic surveillance by CT colonography using axial images only

    International Nuclear Information System (INIS)

    Bruzzi, John F.; Brennan, Darren D.; Fenlon, Helen M.; Moss, Alan C.; MacMathuna, Padraic

    2004-01-01

    Patients at increased risk of colon cancer require strict colon surveillance. Our objective was to establish the efficacy of 2D axial CT colonography as a surveillance test when performed in routine clinical practice. Eighty-two patients at increased risk of colon cancer underwent CT colonography followed by conventional colonoscopy on the same morning. CT colonography studies were performed on a four-ring multidetector CT scanner (100 mAs, 120 kVp, 4 x 2.5 collimation) and were interpreted by two radiologists using 2D axial images only. Results were correlated with findings at colonoscopy. Note was made of subsequent histology reports from polypectomy specimens. A total of 52 polyps were detected at colonoscopy. Using 2D axial images alone, with no recourse to 2D multiplanar or 3D views, the sensitivity of CT colonography was 100, 33 and 19% for polyps larger than 9, 6-9 and smaller than 6 mm, respectively. Per-patient specificities were 98.8, 96 and 81.5%, respectively. Twenty-nine percent of polyps smaller than 1 cm were adenomatous and there were no histological features of severe dysplasia. CT colonography is a useful colon surveillance tool for patients at increased risk of colon cancer. It has a high specificity for identifying patients who should proceed to colonoscopy and polypectomy, while allowing further colon examination to be deferred in patients with normal studies. Using 2D axial images only, CT colonography can be performed as part of the daily CT workload, with a very low rate of referral for unnecessary colonoscopy. (orig.)

  12. CT colonography with rectal iodine tagging: Feasibility and comparison with oral tagging in a colorectal cancer screening population.

    Science.gov (United States)

    Neri, Emanuele; Mantarro, Annalisa; Faggioni, Lorenzo; Scalise, Paola; Bemi, Pietro; Pancrazi, Francesca; D'Ippolito, Giuseppe; Bartolozzi, Carlo

    2015-09-01

    To evaluate feasibility, diagnostic performance, patient acceptance, and overall examination time of CT colonography (CTC) performed through rectal administration of iodinated contrast material. Six-hundred asymptomatic subjects (male:female=270:330; mean 63 years) undergoing CTC for colorectal cancer screening on an individual basis were consecutively enrolled in the study. Out of them, 503 patients (group 1) underwent CTC with rectal tagging, of which 55 had a total of 77 colonic lesions. The remaining 97 patients (group 2) were randomly selected to receive CTC with oral tagging of which 15 had a total of 20 colonic lesions. CTC findings were compared with optical colonoscopy, and per-segment image quality was visually assessed using a semi-quantitative score (1=poor, 2=adequate, 3=excellent). In 70/600 patients (11.7%), CTC was performed twice with both types of tagging over a 5-year follow-up cancer screening program. In this subgroup, patient acceptance was rated via phone interview two weeks after CTC using a semi-quantitative scale (1=poor, 2=fair, 3=average, 4=good, 5=excellent). Mean per-polyp sensitivity, specificity, positive and negative predictive values of CTC with rectal vs oral tagging were 96.1% (CI95% 85.4÷99.3%) vs 89.4% (CI95% 65.4÷98.1%), 95.3% (CI95% 90.7÷97.8%) vs 95.8% (CI95% 87.6÷98.9%), 86.0% (CI95% 73.6÷93.3) vs 85.0% (CI95% 61.1÷96.0%), and 98.8% (CI95% 95.3÷99.8%) vs 97.2% (CI95% 89.4÷99.5%), respectively (p>0.05). Polyp detection rates were not statistically different between groups 1 and 2 (p>0.05). Overall examination time was significantly shorter with rectal than with oral tagging (18.3±3.5 vs 215.6±10.3 minutes, respectively; pRectal iodine tagging can be an effective alternative to oral tagging for CTC with the advantages of greater patient acceptance and lower overall examination time. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  13. Computer-aided polyp detection on CT colonography: Comparison of three systems in a high-risk human population

    International Nuclear Information System (INIS)

    Park, Hee Sun; Kim, Se Hyung; Kim, Jong Hyo; Lee, June-Goo; Kim, Sang Gyun; Lee, Jeong Min; Lee, Jae Young; Han, Joon Koo; Choi, Byung Ihn

    2010-01-01

    Purpose: To compare the detection performances of two commercial and one academic computer-aided diagnosis (CAD) systems for polyp detection on CT colonography (CTC) in a high-risk human population and to assess their detection characteristics. Materials and methods: This retrospective study had institutional review board approval, but informed consent was waived. Sixty-eight patients who were suspected of having colonic polyps and scheduled for colonoscopic polyp removal were included. After CTC was performed using a 64-row MDCT, two commercial (PEV, CAR) and one academic (Hessian matrix-based) CAD systems were applied to each CTC dataset. Colonoscopy using the segmental unblinded technique was performed as a standard of reference. Per-polyp and per-patient sensitivities were calculated and compared for each CAD system. The mean number of false-positives (FPs) and false-negatives (FNs) was computed and the causes of all FPs and FNs were analyzed. Results: A total of 151 polyps in 61 patients were detected (77 polyps <6 mm, 48 6-9.9 mm, 26 ≥ 10 mm). Per-polyp sensitivity for PEV, CAR, and Hessian matrix-based CAD were: 71.6%, 78.4%, and 83.8% for polyps ≥6 mm, and 88.5%, 96.2%, and 96.2% for polyps ≥10 mm. Per-patient sensitivity for polyps ≥6 mm was 80.4%, 89.1%, and 93.5%, and 87%, 95.7%, and 95.7% for polyps ≥10 mm, respectively. Per-polyp and per-patient sensitivities were not significantly different among the three CAD systems regardless of size threshold. Mean number of FPs was 6.9 for PEV, 7.3 for CAR, and 14 for Hessian matrix-based CAD. The most common cause of FPs were feces, followed by extracolonic findings, prominent folds and ileocecal valve, and rectal tube. The distribution of the causes of FPs was significantly different among the three systems. Conclusion: Sensitivity of the three CAD systems for polyp detection was comparable regardless of the polyp size threshold; however, the number of FPs was higher in the Hessian matrix-based CAD

  14. CT colonography with rectal iodine tagging: Feasibility and comparison with oral tagging in a colorectal cancer screening population

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Emanuele, E-mail: emanuele.neri@med.unipi.it [Diagnostic and Interventional Radiology – Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa (Italy); Mantarro, Annalisa; Faggioni, Lorenzo; Scalise, Paola; Bemi, Pietro; Pancrazi, Francesca [Diagnostic and Interventional Radiology – Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa (Italy); D’Ippolito, Giuseppe [Federal University of São Paulo – Sena Madureira 1500 – Vila Mariana, UNIFESP, São Paulo, SP (Brazil); Bartolozzi, Carlo [Diagnostic and Interventional Radiology – Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa (Italy)

    2015-09-15

    Highlights: • In the group receiving rectal tagging, mean per-polyp sensitivity, specificity were 96.1% and 95.3%; while in the group receiving oral tagging, mean per-polyp sensitivity, specificity were 89.4% and 95.8%. The difference between the two groups was not statistically significant (p = 0.549). • Rectal tagging can be an effective alternative to oral tagging. • Rectal tagging allowed greater patient acceptance and lower overall examination time. - Abstract: Purpose: To evaluate feasibility, diagnostic performance, patient acceptance, and overall examination time of CT colonography (CTC) performed through rectal administration of iodinated contrast material. Materials and methods: Six-hundred asymptomatic subjects (male:female = 270:330; mean 63 years) undergoing CTC for colorectal cancer screening on an individual basis were consecutively enrolled in the study. Out of them, 503 patients (group 1) underwent CTC with rectal tagging, of which 55 had a total of 77 colonic lesions. The remaining 97 patients (group 2) were randomly selected to receive CTC with oral tagging of which 15 had a total of 20 colonic lesions. CTC findings were compared with optical colonoscopy, and per-segment image quality was visually assessed using a semi-quantitative score (1 = poor, 2 = adequate, 3 = excellent). In 70/600 patients (11.7%), CTC was performed twice with both types of tagging over a 5-year follow-up cancer screening program. In this subgroup, patient acceptance was rated via phone interview two weeks after CTC using a semi-quantitative scale (1 = poor, 2 = fair, 3 = average, 4 = good, 5 = excellent). Results: Mean per-polyp sensitivity, specificity, positive and negative predictive values of CTC with rectal vs oral tagging were 96.1% (CI{sub 95%} 85.4 ÷ 99.3%) vs 89.4% (CI{sub 95%} 65.4 ÷ 98.1%), 95.3% (CI{sub 95%} 90.7 ÷ 97.8%) vs 95.8% (CI{sub 95%} 87.6 ÷ 98.9%), 86.0% (CI{sub 95%} 73.6 ÷ 93.3) vs 85.0% (CI{sub 95%} 61.1 ÷ 96.0%), and 98.8% (CI{sub 95

  15. CT colonography with rectal iodine tagging: Feasibility and comparison with oral tagging in a colorectal cancer screening population

    International Nuclear Information System (INIS)

    Neri, Emanuele; Mantarro, Annalisa; Faggioni, Lorenzo; Scalise, Paola; Bemi, Pietro; Pancrazi, Francesca; D’Ippolito, Giuseppe; Bartolozzi, Carlo

    2015-01-01

    Highlights: • In the group receiving rectal tagging, mean per-polyp sensitivity, specificity were 96.1% and 95.3%; while in the group receiving oral tagging, mean per-polyp sensitivity, specificity were 89.4% and 95.8%. The difference between the two groups was not statistically significant (p = 0.549). • Rectal tagging can be an effective alternative to oral tagging. • Rectal tagging allowed greater patient acceptance and lower overall examination time. - Abstract: Purpose: To evaluate feasibility, diagnostic performance, patient acceptance, and overall examination time of CT colonography (CTC) performed through rectal administration of iodinated contrast material. Materials and methods: Six-hundred asymptomatic subjects (male:female = 270:330; mean 63 years) undergoing CTC for colorectal cancer screening on an individual basis were consecutively enrolled in the study. Out of them, 503 patients (group 1) underwent CTC with rectal tagging, of which 55 had a total of 77 colonic lesions. The remaining 97 patients (group 2) were randomly selected to receive CTC with oral tagging of which 15 had a total of 20 colonic lesions. CTC findings were compared with optical colonoscopy, and per-segment image quality was visually assessed using a semi-quantitative score (1 = poor, 2 = adequate, 3 = excellent). In 70/600 patients (11.7%), CTC was performed twice with both types of tagging over a 5-year follow-up cancer screening program. In this subgroup, patient acceptance was rated via phone interview two weeks after CTC using a semi-quantitative scale (1 = poor, 2 = fair, 3 = average, 4 = good, 5 = excellent). Results: Mean per-polyp sensitivity, specificity, positive and negative predictive values of CTC with rectal vs oral tagging were 96.1% (CI 95% 85.4 ÷ 99.3%) vs 89.4% (CI 95% 65.4 ÷ 98.1%), 95.3% (CI 95% 90.7 ÷ 97.8%) vs 95.8% (CI 95% 87.6 ÷ 98.9%), 86.0% (CI 95% 73.6 ÷ 93.3) vs 85.0% (CI 95% 61.1 ÷ 96.0%), and 98.8% (CI 95% 95.3 ÷ 99.8%) vs 97.2% (CI 95% 89

  16. Diagnostic Performance of CT Colonography for the Detection of Colorectal Polyps

    International Nuclear Information System (INIS)

    Yun, Ji Young; Ro, Hee Jeong; Choi, Jung Bin; Chung, Ji Eun; Kim, Yong Jin; Suh, Won Hyuck; Lee, Jong Kyun; Park, Jong Beom

    2007-01-01

    To investigate the diagnostic value of CT colonography for the detection of colorectal polyps. From December 2004 to December 2005, 399 patients underwent CT colonography and follow-up conventional colonoscopy. We excluded cases of advanced colorectal cancer. We retrospectively analyzed the CT colonography findings and follow-up conventional colonoscopy findings of 113 patients who had polyps more than 6 mm in diameter. Radiologists using 3D and 2D computer generated displays interpreted the CT colonography images. The colonoscopists were aware of the CT colonography findings before the procedure. CT colonography detected 132 polyps in 107 of the 113 patients and conventional colonoscopy detected 114 colorectal polyps more than 6 mm in diameter in 87 of the 113 patients. The sensitivity of CT colonography analyzed per polyp was 91% (41/45) for polyps more than 10 mm in diameter and 89% (101/114) for polyps more than 6 mm in diameter. Thirteen polyps were missed by CT colonography and were detected on follow-up conventional colonoscopy. CT colonography is a sensitive diagnostic tool for the detection of colorectal polyps and adequate bowel preparation, optimal bowel distention and clinical experience are needed to reduce the rate of missing appropriate lesions

  17. CT colonography in a Korean population with a high residue diet: Comparison between wet and dry preparations

    International Nuclear Information System (INIS)

    Kim, S.H.; Choi, B.I.; Han, J.K.; Lee, J.M.; Eun, H.W.; Lee, J.Y.; Lee, K.H.; Han, C.J.; Choi, Y.H.; Shin, K.-S.

    2006-01-01

    AIM: To compare wet and dry preparation methods for computed tomography colonography (CTC) in terms of preparation quality, interpretation time, and diagnostic performance for polyp detection in a population with a high residue diet. MATERIALS AND METHODS: Eighty-six patients were divided into two groups. Group 1 (n=24) received a wet preparation of 4 l polyethylene glycol (PEG) solution, and group 2 (n=62) received a dry preparation of phosphor-soda. Abnormal findings, including polyps, and the time required to interpret the CTC images in both groups were documented by a radiologist. CTC findings were compared to those of colonoscopy as a reference standard. Two radiologists evaluated the quality of CTC with regard to residual fluid, faeces, and colonic distension using a four-point scale in consensus. Statistical differences for residual fluid, faeces, distensibility on CTC, and interpretation time between the two groups were analysed. The diagnostic performance of CTC in both groups was also compared. RESULTS: One-hundred and ninety polyps in 70 patients were identified using colonoscopy. Regarding the quality of images produced the wet preparation was significantly better than the dry preparation (p 0.05). CONCLUSION: In a population with a high-residue diet, CTC with wet preparation can be interpreted in a time-efficient manner and is comparable with CTC with dry preparation

  18. CT colonography: current status in Europe and future perspectives

    International Nuclear Information System (INIS)

    Lefere, P.; Gryspeerdt, S.; Yoshida, H.

    2007-01-01

    In this article, we review the current status of CT colonography (CTC) in Europe and future perspectives of CTC including fecal tagging and CAD. There are several large multi-centre studies that have been initiated. Fecal tagging has gradually become a prerequisite to perform state-of-the-art CTC. However, CAD for fecal-tagging CTC remains a subject for future research. (orig.)

  19. Iohexol versus diatrizoate for fecal/fluid tagging during CT colonography performed with cathartic preparation: comparison of examination quality

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bohyun; Park, Seong Ho; Hong, Gil-Sun; Lee, Jong Seok; Kim, Hyun Jin; Kim, Ah Young; Ha, Hyun Kwon [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of); Lee, Ju Hee [National Cancer Center, Department of Radiology, Gyeonggi-do (Korea, Republic of)

    2015-06-01

    We aimed to compare iohexol vs. diatrizoate as fecal/fluid tagging agents for computed tomography colonography (CTC) regarding examination quality. Forty prospective patients (M:F = 23:17; 63 ± 11.6 years) received CTC using 50 mL (350 mgI/mL) oral iohexol for tagging. Forty other indication-matched, age-matched, and sex-matched patients who underwent CTC using 100 mL diatrizoate for tagging and otherwise the same technique, were retrospectively identified. Two groups were compared regarding overall examination quality, per-patient and per-segment scores of colonic bubbles (0 [no bubbles] to 5 [the largest amount]), and the volume, attenuation, and homogeneity (untagged, layered, and homogeneous) of the residual colonic fluid. The iohexol group demonstrated a greater amount of colonic bubbles than the diatrizoate group: mean per-patient scores ± SD of 1.2 ± 0.8 vs. 0.7 ± 0.6, respectively (p = 0.003); and rates of segments showing ≥ grade 3 bubbles of 12.9 % (85/659) vs. 1.6 % (11/695), respectively (p = 0.001). Residual colonic fluid amount standardized to the colonic volume did not significantly differ: 7.2 % ± 4.2 vs. 7.8 % ± 3.7, respectively (p = 0.544). Tagged fluid attenuation was mostly comparable between groups and the fluid was homogeneously tagged in 98.7 % (224/227) vs. 99.5 % (218/219) segments, respectively (p = 0.344). Iohexol caused more colonic bubbles when used during cathartic CTC. Otherwise, examination quality was similarly adequate with both iohexol and diatrizoate. (orig.)

  20. Intra-individual comparison of magnesium citrate and sodium phosphate for bowel preparation at CT colonography: Automated volumetric analysis of residual fluid for quality assessment

    International Nuclear Information System (INIS)

    Bannas, P.; Bakke, J.; Munoz del Rio, A.; Pickhardt, P.J.

    2014-01-01

    Aim: To perform an objective, intra-individual comparison of residual colonic fluid volume and attenuation associated with the current front-line laxative magnesium citrate (MgC) versus the former front-line laxative sodium phosphate (NaP) at CT colonography (CTC). Materials and methods: This retrospective Health Insurance and Portability and Accountability Act-compliant study had institutional review board approval; informed consent was waived. The study cohort included 250 asymptomatic adults (mean age at index 56.1 years; 124 male/126 female) who underwent CTC screening twice over a 5 year interval. Colon catharsis at initial and follow-up screening employed single-dose NaP and double-dose MgC, respectively, allowing for intra-patient comparison. Automated volumetric analysis of residual colonic fluid volume and attenuation was performed on all 500 CTC studies. Colonic fluid volume <200 ml and mean attenuation between 300–900 HU were considered optimal. Paired t-test and McNemar's test were used to compare differences. Results: Residual fluid volumes <200 ml were recorded in 192 examinations (76.8%) following MgC and in 204 examinations (81.6%) following NaP (p = 0.23). The mean total residual fluid volume was 155 ± 114 ml for MgC and 143 ± 100 ml for NaP (p = 0.01). The attenuation range of 300–900 HU was significantly more frequent for MgC (n = 220, 88%) than for NaP (n = 127, 50.8%; p < 0.001). Mean fluid attenuation was significantly lower for MgC (700 ± 165 HU) than for NaP (878 ± 155 HU; p < 0.001). Concomitant presence of both optimal fluid volume and attenuation was significantly more frequent for MgC 65.2% than for NaP (38%; p < 0.001). Conclusions: Objective intra-individual comparison using automated volumetric analysis suggests that the replacement of NaP by MgC as the front-line laxative for CTC has not compromised overall examination quality. - Highlights: • Automated volumetric analysis provides

  1. Comprehensive Assessment of Osteoporosis and Bone Fragility with CT Colonography

    Science.gov (United States)

    Murthy, Naveen S.; Khosla, Sundeep; Clarke, Bart L.; Bruining, David H.; Kopperdahl, David L.; Lee, David C.; Keaveny, Tony M.

    2016-01-01

    Purpose To evaluate the ability of additional analysis of computed tomographic (CT) colonography images to provide a comprehensive osteoporosis assessment. Materials and Methods This Health Insurance Portability and Accountability Act–compliant study was approved by our institutional review board with a waiver of informed consent. Diagnosis of osteoporosis and assessment of fracture risk were compared between biomechanical CT analysis and dual-energy x-ray absorptiometry (DXA) in 136 women (age range, 43–92 years), each of whom underwent CT colonography and DXA within a 6-month period (between January 2008 and April 2010). Blinded to the DXA data, biomechanical CT analysis was retrospectively applied to CT images by using phantomless calibration and finite element analysis to measure bone mineral density and bone strength at the hip and spine. Regression, Bland-Altman, and reclassification analyses and paired t tests were used to compare results. Results For bone mineral density T scores at the femoral neck, biomechanical CT analysis was highly correlated (R2 = 0.84) with DXA, did not differ from DXA (P = .15, paired t test), and was able to identify osteoporosis (as defined by DXA), with 100% sensitivity in eight of eight patients (95% confidence interval [CI]: 67.6%, 100%) and 98.4% specificity in 126 of 128 patients (95% CI: 94.5%, 99.6%). Considering both the hip and spine, the classification of patients at high risk for fracture by biomechanical CT analysis—those with osteoporosis or “fragile bone strength”—agreed well against classifications for clinical osteoporosis by DXA (T score ≤−2.5 at the hip or spine), with 82.8% sensitivity in 24 of 29 patients (95% CI: 65.4%, 92.4%) and 85.7% specificity in 66 of 77 patients (95% CI: 76.2%, 91.8%). Conclusion Retrospective biomechanical CT analysis of CT colonography for colorectal cancer screening provides a comprehensive osteoporosis assessment without requiring changes in imaging protocols.

  2. Improving Polyp Detection Algorithms for CT Colonography: Pareto Front Approach.

    Science.gov (United States)

    Huang, Adam; Li, Jiang; Summers, Ronald M; Petrick, Nicholas; Hara, Amy K

    2010-03-21

    We investigated a Pareto front approach to improving polyp detection algorithms for CT colonography (CTC). A dataset of 56 CTC colon surfaces with 87 proven positive detections of 53 polyps sized 4 to 60 mm was used to evaluate the performance of a one-step and a two-step curvature-based region growing algorithm. The algorithmic performance was statistically evaluated and compared based on the Pareto optimal solutions from 20 experiments by evolutionary algorithms. The false positive rate was lower (pPareto optimization process can effectively help in fine-tuning and redesigning polyp detection algorithms.

  3. Computer-aided diagnosis of colonic polyp by CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2007-01-01

    The outcome of National CT Colonography Trial, by American College of Radiology Imaging Network, 2006 (www.acrin.org/6664 protocol), possibly leads to the introduction of colorectal cancer screening in the US because CT colonography (CTCG) has been approved in the health insurance system. This paper describes the outline of computer-aided diagnosis (CAD) of colonic polyp by CTCG, its polyp detectability and future aspects. CTCG essentially derives from the virtual, abdominal 3D CT images and gives as many as about 500 images/patient, in the reading of which CAD support the expert. CAD technology in CTCG is said to have been essentially established in the first half of 2000s, which involves the cleansing of fecal tagging effect, extraction of the colonal wall from the image, detection of suspicious polyp, reduction of false-positive findings and displaying of the detected polyp. The detectability is thought to be at comparable level to expert's. The last displaying is done on the user-interface like Colon CAD Workstation. More efficient expert's reading with CAD, imaging without previous gut cleansing, detection of the flat lesion and further reduction of false-positive are the forthcoming tasks in clinical practice. Significance of CTCG is becoming in realization and its usage with CAD is thought to be more popular in Japan. (R.T.)

  4. Extra colonic Findings on CT Colonography in Symptomatic Patients

    International Nuclear Information System (INIS)

    Drahovska, I.; Nigut, F.; Mach, P.; Lazurova, I.; Gombosova, L.

    2011-01-01

    The paper is an analysis of the consequences of the extra colonic findings identified on CT colonography examination of symptomatic patients and the validity of the intravenous application of contrast medium in this examination. The authors enrolled 252 patients, who underwent CT colonogprahy.128 extra colonic findings was identified in 80 patients (31.74%). The average age was 65.62 years (SD = 12.7, min. age was 29, max. age. 85 years). According the clinical significance the extra colonic findings have been divided into three groups – low, moderate and very important extra colonic findings. Low significant findings were 68 (53.12%), moderate 26 (20.31%) and very important extra colonic findings were 34 (26.56%), of which 30 were malignant nature. (author)

  5. Evaluation of image quality and lesion perception by human readers on 3D CT colonography: comparison of standard and low radiation dose

    International Nuclear Information System (INIS)

    Fisichella, Valeria A.; Allansdotter Johnsson, Aase; Hellstroem, Mikael; Baath, Magnus; Jaederling, Fredrik; Bergsten, Tommy; Persson, Ulf; Mellingen, Kristin

    2010-01-01

    We compared the prevalence of noise-related artefacts and lesion perception on three-dimensional (3D) CT colonography (CTC) at standard and low radiation doses. Forty-eight patients underwent CTC (64 x 0.625 mm collimation; tube rotation time 0.5 s; automatic tube current modulation: standard dose 40-160 mA, low dose 10-50 mA). Low- and standard-dose acquisitions were performed in the supine position, one after the other. The presence of artefacts (cobblestone and snow artefacts, irregularly delineated folds) and the presence of polyps were evaluated by five radiologists on 3D images at standard dose, the original low dose and a modified low dose, i.e. after manipulation of opacity on 3D. The mean effective dose was 3.9 ± 1.3 mSv at standard dose and 1.03 ± 0.4 mSv at low dose. The number of images showing cobblestone artefacts and irregularly delineated folds at original and modified low doses was significantly higher than at standard dose (P < 0.0001). Most of the artefacts on modified low-dose images were mild. No significant difference in sensitivity between the dose levels was found for polyps ≥6 mm. Reduction of the effective dose to 1 mSv significantly affects image quality on 3D CTC, but the perception of ≥6 mm lesions is not significantly impaired. (orig.)

  6. CT colonography: interpretative performance in a non-academic environment

    International Nuclear Information System (INIS)

    Burling, D.; Halligan, S.; Atchley, J.; Dhingsar, R.; Guest, P.; Hayward, S.; Higginson, A.; Jobling, C.; Kay, C.; Lilford, R.; Maskell, G.; McCafferty, I.; McGregor, J.; Morton, D.; Kumar Neelala, M.; Noakes, M.; Philips, A.; Riley, P.; Taylor, A.; Bassett, P.; Wardle, J.; Atkin, W.; Taylor, S.A.

    2007-01-01

    Aim: To investigate interpretative accuracy and reporting time for radiologists performing computed tomography (CT) colonography in day-to-day non-academic clinical practice. Materials and methods: Thirteen radiologists from seven centres, who were reporting CT colonography in non-academic daily clinical practice, interpreted a dataset of 15 colonoscopically validated cases in a controlled environment. Ten cases had either a cancer or polyp >10 mm; one case had a medium polyp and four were normal. Correct case categorization and interpretation times were compared using analysis of variance to aggregated results obtained from both experienced observers and observers recently trained using 50 cases, working in an academic environment. The effect of experience was determined using Spearman's rank correlation. Results: Individual accuracy was highly variable, range 53% (95% CI 27-79%) to 93% (95% CI 68-100%). Mean accuracy overall was significantly inferior to experienced radiologists (mean 75 versus 88%, p = 0.04) but not significantly different from recently trained radiologists (p = 0.48). Interpretation time was not significantly different to experienced readers (mean 12.4 min versus 11.7, p = 0.74), but shorter than recently trained radiologists (p = 0.05). There was a significant, positive, linear correlation between prior experience and accuracy (p < 0.001) with no plateau. Conclusion: Accuracy for sub-specialist radiologists working in a non-academic environment is, on average, equivalent to radiologists trained using 50 cases. However, there is wide variability in individual performance, which generally falls short of the average performance suggested by meta-analysis of published data. Experience improves accuracy, but alone is insufficient to determine competence

  7. Sub-milliSievert (sub-mSv) CT colonography: a prospective comparison of image quality and polyp conspicuity at reduced-dose versus standard-dose imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lubner, Meghan G.; Pooler, B.D.; Kitchin, Douglas R.; Kim, David H.; Munoz del Rio, Alejandro; Pickhardt, Perry J. [University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, Departments of Radiology, Madison, WI (United States); Tang, Jie [University of Wisconsin School of Medicine and Public Health, Medical Physics, Madison, WI (United States); Li, Ke; Chen, Guang-Hong [University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, Departments of Radiology, Madison, WI (United States); University of Wisconsin School of Medicine and Public Health, Medical Physics, Madison, WI (United States)

    2015-07-15

    To prospectively compare reduced-dose (RD) CT colonography (CTC) with standard-dose (SD) imaging using several reconstruction algorithms. Following SD supine CTC, 40 patients (mean age, 57.3 years; 17 M/23 F; mean BMI, 27.2) underwent an additional RD supine examination (targeted dose reduction, 70-90 %). DLP, CTDI{sub vol}, effective dose, and SSDE were compared. Several reconstruction algorithms were applied to RD series. SD-FBP served as reference standard. Objective image noise, subjective image quality and polyp conspicuity were assessed. Mean CTDI{sub vol} and effective dose for RD series was 0.89 mGy (median 0.65) and 0.6 mSv (median 0.44), compared with 3.8 mGy (median 3.1) and 2.8 mSv (median 2.3) for SD series, respectively. Mean dose reduction was 78 %. Mean image noise was significantly reduced on RD-PICCS (24.3 ± 19HU) and RD-MBIR (19 ± 18HU) compared with RD-FBP (90 ± 33), RD-ASIR (72 ± 27) and SD-FBP (47 ± 14 HU). 2D image quality score was higher with RD-PICCS, RD-MBIR, and SD-FBP (2.7 ± 0.4/2.8 ± 0.4/2.9 ± 0.6) compared with RD-FBP (1.5 ± 0.4) and RD-ASIR (1.8 ± 0.44). A similar trend was seen with 3D image quality scores. Polyp conspicuity scores were similar between SD-FBP/RD-PICCS/RD-MBIR (3.5 ± 0.6/3.2 ± 0.8/3.3 ± 0.6). Sub-milliSievert CTC performed with iterative reconstruction techniques demonstrate decreased image quality compared to SD, but improved image quality compared to RD images reconstructed with FBP. (orig.)

  8. Assessment of two different software solutions for the evaluation of CT colonography

    International Nuclear Information System (INIS)

    Andersen, K.; Blondin, D.; Moedder, U.; Cohnen, M.; Beck, A.; Aurich, V.; Vogt, C.

    2005-01-01

    Purpose: To compare a commercial CT colonography software ('Colonography', Siemens, Forchheim) with a non-commercial post-processing system ('Colotux', Department of Informatics). Material and methods: Identical data sets of 10 patients, who underwent an ultra-low-dose multi-detector CT colonography (ULD-MDCTC) (4 x 1 mm collimation, 8 mm pitch, 120 kVp, 10 mAs) were analyzed retrospectively. Assessment was performed using both software solutions by two resident radiologists, who did not have any experience with any colonography software tool before and who did not know the clinical symptoms of the patients or the results of the conventional colonoscopy. Both systems were analyzed using several subjective quality criteria including workflow, handling, image quality, endoluminal navigation and analysis of lesions with grading on a 5-point-scale. Results concerning polyps were compared between the two systems as well as with conventional colonoscopy. Results: Both colonography systems detected the same number of polyps. Although both showed some advantages for single criteria, no relevant difference was noted in general for subjective assessment. The time for calculation of three dimensional interactive volumes was three times longer for 'Colotux' compared to 'Colonography'. Linux-based 'Colotux' showed a trend towards better subjective image quality and easier measurement of polyp size. An intuitive desktop and 'Syngo'-workflow integration were advantages of 'Colonography'. Conclusion: The analysis of CT colonographies (4-detector-row-CT-scanner, ultra low dose technique, supine position) can adequately be achieved by both software solutions. There was no significant subjective or objective difference of quality between a 'stand-alone' individual system and a commerical workflow-integrated solution. A relevant factor for decision between the two systems may be the difference in time needed for the 3D volume calculation, especially in institutes with a high frequency

  9. CT colonography combined with fistulography - a case of periannal fistula of a 6 months old child

    International Nuclear Information System (INIS)

    Sirakov, N.; Velkova, K.; Sirakov, V.; Tashev, P.

    2007-01-01

    We present a 6 months old child with perianal fistula with repeated secretion from it. The child was examined by double contrast barium enema and transrectal ultrasonography that gave suggestions of perianal fistula with no communication to the rectum and suspicion of a anal duplication of the rectum. The child was examined by CT colonography combined with fistulography. The exam was carried out on a axial CT Somatom Emotion by Siemens. The purpose of our report is to present the results of the combination of CT colonography and fistulography, applied to a 6-month-old child, as well as to present the specific protocol that we used for this examination. (authors)

  10. CT colonography and transient bacteraemia: implications for antibiotic prophylaxis

    Energy Technology Data Exchange (ETDEWEB)

    Ridge, C.A.; Carter, M.R.; Ryan, R.; Hegarty, C.; Malone, D.E. [St Vincent' s University Hospital, Department of Radiology, Dublin 4 (Ireland); Browne, L.P. [Texas Children' s Hospital, Department of Diagnostic Imaging, Houston, TX (United States); Schaffer, K. [St Vincent' s University Hospital, Department of Microbiology, Dublin 4 (Ireland)

    2011-02-15

    To determine the prevalence of transient bacteraemia after CT colonography (CTC). Blood cultures were obtained at 5, 10 and 15 min after CTC from 100 consecutive consenting patients. Blood samples were cultured in both aerobic and anaerobic media and positive blood culture samples were analysed by a microbiologist. Blood culture samples were positive for growth in sixteen patients. All positive blood culture samples were confirmed skin contaminants. There were no cases of significant bacteraemia. The estimated significant bacteraemia rate as a result of CTC is 0-3.7%, based on 95% confidence intervals around extreme results using Wilson's score method. American Heart Association and National Institute for Clinical Excellence guidelines advise that antibiotic prophylaxis before lower gastrointestinal endoscopy is not indicated in patients with at risk cardiac lesions (ARCL) as the risk of a transient bacteraemia leading to infective endocarditis is low. These data show that the prevalence of transient bacteraemia after CTC is also low. It follows that patients with ARCL do not require antibiotic prophylaxis before CTC. (orig.)

  11. CT colonography and transient bacteraemia: implications for antibiotic prophylaxis

    International Nuclear Information System (INIS)

    Ridge, C.A.; Carter, M.R.; Ryan, R.; Hegarty, C.; Malone, D.E.; Browne, L.P.; Schaffer, K.

    2011-01-01

    To determine the prevalence of transient bacteraemia after CT colonography (CTC). Blood cultures were obtained at 5, 10 and 15 min after CTC from 100 consecutive consenting patients. Blood samples were cultured in both aerobic and anaerobic media and positive blood culture samples were analysed by a microbiologist. Blood culture samples were positive for growth in sixteen patients. All positive blood culture samples were confirmed skin contaminants. There were no cases of significant bacteraemia. The estimated significant bacteraemia rate as a result of CTC is 0-3.7%, based on 95% confidence intervals around extreme results using Wilson's score method. American Heart Association and National Institute for Clinical Excellence guidelines advise that antibiotic prophylaxis before lower gastrointestinal endoscopy is not indicated in patients with at risk cardiac lesions (ARCL) as the risk of a transient bacteraemia leading to infective endocarditis is low. These data show that the prevalence of transient bacteraemia after CTC is also low. It follows that patients with ARCL do not require antibiotic prophylaxis before CTC. (orig.)

  12. CT colonography and transient bacteraemia: implications for antibiotic prophylaxis.

    LENUS (Irish Health Repository)

    Ridge, C A

    2012-02-01

    OBJECTIVES: To determine the prevalence of transient bacteraemia after CT colonography (CTC). METHODS: Blood cultures were obtained at 5, 10 and 15 min after CTC from 100 consecutive consenting patients. Blood samples were cultured in both aerobic and anaerobic media and positive blood culture samples were analysed by a microbiologist. RESULTS: Blood culture samples were positive for growth in sixteen patients. All positive blood culture samples were confirmed skin contaminants. There were no cases of significant bacteraemia. The estimated significant bacteraemia rate as a result of CTC is 0-3.7%, based on 95% confidence intervals around extreme results using Wilson\\'s score method. CONCLUSIONS: American Heart Association and National Institute for Clinical Excellence guidelines advise that antibiotic prophylaxis before lower gastrointestinal endoscopy is not indicated in patients with at risk cardiac lesions (ARCL) as the risk of a transient bacteraemia leading to infective endocarditis is low. These data show that the prevalence of transient bacteraemia after CTC is also low. It follows that patients with ARCL do not require antibiotic prophylaxis before CTC.

  13. Current status on performance of CT colonography and clinical indications

    International Nuclear Information System (INIS)

    Laghi, Andrea; Rengo, Marco; Graser, Anno; Iafrate, Franco

    2013-01-01

    CT colonography (CTC) is a robust and reliable imaging test of the colon. Accuracy for the detection of colorectal cancer (CRC) is as high as conventional colonoscopy (CC). Identification of polyp is size dependent, with large lesions (≥10 mm) accurately detected and small lesions (6–9 mm) identified with moderate to good sensitivity. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. Current CTC indications include the evaluation of patients who had undergone a previous incomplete CC or those who are unfit for CC (elderly and frail individuals, patients with underlying severe clinical conditions, or with contraindication to sedation). CTC can also be efficiently used in the assessment of diverticular disease (excluding patients with acute diverticulitis, where the exam should be postponed), before laparoscopic surgery for CRC (to have an accurate localization of the lesion), in the evaluation of colonic involvement in the case of deep pelvic endometriosis (replacing barium enema). CTC is also a safe procedure in patients with colostomy. For CRC screening, CTC should be considered an opportunistic screening test (not available for population, or mass screening) to be offered to asymptomatic average-risk individuals, of both genders, starting at age 50. The use in individuals with positive family history should be discussed with the patient first. Absolute contraindication is to propose CTC for surveillance of genetic syndromes and chronic inflammatory bowel diseases (in particular, ulcerative colitis). The use of CTC in the follow-up after surgery for CRC is achieving interesting evidences despite the fact that literature data are still relatively weak in terms of numerosity of the studied populations. In patients who underwent previous polypectomy CTC cannot be recommended as first test because debate is still open. It is desirable that in the future CTC would be the first-line and only diagnostic test for

  14. Current status on performance of CT colonography and clinical indications

    Energy Technology Data Exchange (ETDEWEB)

    Laghi, Andrea, E-mail: andrea.laghi@uniroma1.it [Department of Radiological Sciences, Oncology and Pathology Sapienza – Università di Roma, Polo Pontino, I.C.O.T. Hospital, Via Franco Faggiana 43, 04100 Latina (Italy); Rengo, Marco [Department of Radiological Sciences, Oncology and Pathology Sapienza – Università di Roma, Polo Pontino, I.C.O.T. Hospital, Via Franco Faggiana 43, 04100 Latina (Italy); Graser, Anno [InstitutfürKlinische Radiologie, Klinikumder Ludwig-Maximilians-Universität München, Campus Großhadern, Marchioninistr. 15, 81377 München (Germany); Iafrate, Franco [Department of Radiological Sciences, Oncology and Pathology Sapienza – Università di Roma, Policlinico Umberto I, Viale Regina Elena 324, 00161 Rome (Italy)

    2013-08-15

    CT colonography (CTC) is a robust and reliable imaging test of the colon. Accuracy for the detection of colorectal cancer (CRC) is as high as conventional colonoscopy (CC). Identification of polyp is size dependent, with large lesions (≥10 mm) accurately detected and small lesions (6–9 mm) identified with moderate to good sensitivity. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. Current CTC indications include the evaluation of patients who had undergone a previous incomplete CC or those who are unfit for CC (elderly and frail individuals, patients with underlying severe clinical conditions, or with contraindication to sedation). CTC can also be efficiently used in the assessment of diverticular disease (excluding patients with acute diverticulitis, where the exam should be postponed), before laparoscopic surgery for CRC (to have an accurate localization of the lesion), in the evaluation of colonic involvement in the case of deep pelvic endometriosis (replacing barium enema). CTC is also a safe procedure in patients with colostomy. For CRC screening, CTC should be considered an opportunistic screening test (not available for population, or mass screening) to be offered to asymptomatic average-risk individuals, of both genders, starting at age 50. The use in individuals with positive family history should be discussed with the patient first. Absolute contraindication is to propose CTC for surveillance of genetic syndromes and chronic inflammatory bowel diseases (in particular, ulcerative colitis). The use of CTC in the follow-up after surgery for CRC is achieving interesting evidences despite the fact that literature data are still relatively weak in terms of numerosity of the studied populations. In patients who underwent previous polypectomy CTC cannot be recommended as first test because debate is still open. It is desirable that in the future CTC would be the first-line and only diagnostic test for

  15. Colon distension and scan protocol for CT-colonography: an overview

    NARCIS (Netherlands)

    Boellaard, Thierry N.; de Haan, Margriet C.; Venema, Henk W.; Stoker, Jaap

    2013-01-01

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension,

  16. Evaluation of a radiographer tele-training programme in the interpretation of CT Colonography

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl; Lefere, Philippe

    2012-01-01

    Colorectal cancer is one of the most common, and deadly human cancers. By early identifi cation of suspect lesions, screening has the potential to reduce mortality. Colonos- copy remains the screening gold standard, but “virtual colonoscopy“ or CT-colonography (CTC) has been shown to generate...

  17. Electronic cleansing for computed tomography (CT) colonography using a scale-invariant three-material model

    NARCIS (Netherlands)

    Serlie, Iwo W. O.; Vos, Frans M.; Truyen, Roel; Post, Frits H.; Stoker, Jaap; van Vliet, Lucas J.

    2010-01-01

    A well-known reading pitfall in computed tomography (CT) colonography is posed by artifacts at T-junctions, i.e., locations where air-fluid levels interface with the colon wall. This paper presents a scale-invariant method to determine material fractions in voxels near such T-junctions. The proposed

  18. Electronic cleansing for 24-h limited bowel preparation CT colonography using principal curvature flow

    NARCIS (Netherlands)

    van Ravesteijn, Vincent F.; Boellaard, Thierry N.; van der Paardt, Marije P.; Serlie, Iwo W. O.; de Haan, Margriet C.; Stoker, Jaap; van Vliet, Lucas J.; Vos, Frans M.

    2013-01-01

    CT colonography (CTC) is one of the recommended methods for colorectal cancer screening. The subject's preparation is one of the most burdensome aspects of CTC with a cathartic bowel preparation. Tagging of the bowel content with an oral contrast medium facilitates CTC with limited bowel

  19. Bowel preparation in CT colonography: electrolyte and renal function disturbances in the frail and elderly patient.

    LENUS (Irish Health Repository)

    Mc Laughlin, Patrick

    2010-03-01

    Elderly patients are at increased risk of biochemical disturbances secondary to cathartic medications. This study investigates the renal function, electrolyte and clinical disturbances associated with CT colonography (CTC) with sodium picosulphate-magnesium citrate (SPS-MC) in a subgroup of frail, elderly patients.

  20. Limited-preparation CT colonography in frail elderly patients: a feasibility study.

    LENUS (Irish Health Repository)

    Keeling, Aoife N

    2010-05-01

    Full colonic preparation can be onerous and may be poorly tolerated in frail elderly patients. The purpose of this study was to prospectively assess the image quality and diagnostic yield of limited-preparation CT colonography (CTC) in elderly patients with suspected colorectal cancer who were deemed medically unfit or unsuitable for colonoscopy.

  1. Efficacy of IV Buscopan as a muscle relaxant in CT colonography

    International Nuclear Information System (INIS)

    Bruzzi, John F.; Brennan, Darren D.; Fenlon, Helen M.; Moss, Alan C.; MacMathuna, Padraic

    2003-01-01

    The aim of this study was to examine the efficacy of IV Buscopan as a muscle relaxant in CT colonography in terms of colonic distension and polyp detection, and to determine its particular efficacy in patients with diverticular disease. Seventy-three consecutive patients were randomised to receive IV Buscopan or no muscle relaxant prior to CT colonography. CT colonography was performed using a Siemens Somatom 4-detector multislice CT scanner. The following parameters were recorded: degree of colonic distension using a 4-point scale; diagnostic adequacy of colonic distension; presence or absence of diverticular disease; and presence of colonic polyps. Accuracy of polyp detection was assessed using subsequent conventional colonoscopy as a gold standard. There was no significant difference between the two groups in the number of segments that were deemed to be optimally or adequately distended (p=0.37). Although IV Buscopan did improve distension of certain segments, this effect was not sufficient to improve the number of diagnostically adequate studies in the Buscopan group (p=0.14). In patients with diverticular disease, IV Buscopan did not have any significant effect on segments affected by diverticulosis but was associated with an improvement in distension of more proximal segments. There was no significant difference between the two groups in terms of polyp detection (p=0.34). The addition of prone scanning to supine scanning was found to be the most useful technique for maximising colonic distension. Intravenous Buscopan at CT colonography does not improve the overall adequacy of colonic distension nor the accuracy of polyp detection. In patients with sigmoid diverticular disease IV Buscopan improves distension of more proximal colonic segments and may be useful in selected cases, but our results do not support its routine use for CT colonography. (orig.)

  2. CT colonography: a survey of general practitioners' knowledge and interest.

    Science.gov (United States)

    Flor, Nicola; Laghi, Andrea; Peri, Mauro; Cornalba, Gianpaolo; Sardanelli, Francesco

    2016-01-01

    To verify the knowledge and interest of general practitioners on computed tomography colonography (CTC). In 2014, a Web-based questionnaire was proposed to all general practitioners of [Milan, Italy]. The questionnaire consisted of ten questions concerning general practitioners' knowledge about CTC, including application of guidelines in clinical scenarios and diagnostic performance. Out of 1,053 general practitioners, 231 (22%), 155 men and 76 women (mean age 58 years), completed the survey. We found a significant difference between the age of responders and that of non-responders (p = 0.0033). Of the 231 responders, 84% were aware of the possibility of using CTC as a method for examining the colon-rectum. However, only 57% were aware about low X-ray exposure delivered by CTC and about the possibility of using a reduced cleansing protocol. Only 48% were aware that CTC accuracy in diagnosing 10-mm or larger polyps and colorectal cancers was similar to that of conventional colonoscopy, while 62% were informed about CTC advantages in comparison with double-contrast barium enema; 59% thought that CTC had a potential role as a screening test; 85-86% suggested CTC in the case of refused or incomplete conventional colonoscopy; 79% suggested immediate conventional colonoscopy in the case of at least one 10-mm polyp. About 54% usually prescribe one CTC every 4-6 months, while 36% never have, 3% one CTC per month, and 7% one every 2-3 months. Ninety-four per cent declared that they were willing to attend a course on CTC. General practitioners have limited knowledge concerning CTC. Radiological societies should fill this gap offering dedicated educational initiatives.

  3. CT colonography for surveillance of patients with colorectal cancer: Systematic review and meta-analysis of diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Porte, Francois; Burling, David [St. Mark' s Hospital, Department of Radiology, Harrow (United Kingdom); Uppara, Mallikarjuna; Malietzis, George; Faiz, Omar [Trials and Outcome Centre (SETOC) St Mark' s Hospital, Surgical Epidemiology, Harrow (United Kingdom); Halligan, Steve [University College London, Department of Radiology, London (United Kingdom); Athanasiou, Thanos [Imperial College London, Department of Surgery and Cancer, London (United Kingdom)

    2017-01-15

    To review primary research evidence investigating performance of CT colonography for colorectal cancer surveillance. The financial impact of using CT colonography for surveillance was also estimated. We identified primary studies of CT colonography for surveillance of colorectal cancer patients. A summary ROC curve was constructed. Inter-study heterogeneity was explored using the I2 value. Financial impact was estimated for a theoretical cohort of patients, based on Cancer Research UK statistics. Seven studies provided data on 880 patients. Five of seven studies (765 patients) were included for qualitative analysis. Sensitivity of CT colonography for detection of anastomotic recurrence was 95 % (95 % CI 62 - 100), specificity 100 % (95 % CI 75 - 100) and sensitivity for metachronous cancers was 100 %. No statistical heterogeneity was detected (I2 = 0 %). We estimated that CT colonography as a 'single test' alternative to colonoscopy and standard CT for surveillance would potentially save EUR20,785,232 (pound 14,803,404) for an annual cohort of UK patients. CT colonography compares favourably to colonoscopy for detection of anastomotic recurrence and metachronous colorectal cancer, and appears financially beneficial. These findings should be considered alongside limitations of small patient numbers and high clinical heterogeneity between studies. (orig.)

  4. Radiation protection in newer medical imaging techniques: CT colonography

    International Nuclear Information System (INIS)

    2008-01-01

    Multislice/detector computed tomography (CT) scanning, applied to visualization of the colon in CT colonography (CTC), also known as virtual colonoscopy (VC), is a relatively new application of CT introduced in recent years. The possibility of its application in population screening techniques raises a number of questions. Effort is required to ensure that the benefit of this new practice will not pose an undue level of detriment to the individual in multiple examinations. For practitioners and regulators, it is evident that innovation has been driven by both the imaging industry and by an ever increasing array of new applications generated and validated in the clinical environment. Regulation, industrial standardization, safety procedures and advice on best practice lag (inevitably) behind the industrial and clinical innovations being achieved. This series of Safety Reports (Nos 58, 60 and 61) is designed to help fill this growing vacuum, by bringing up to date and timely advice to bear on the problems involved. Under its statutory responsibility to establish standards for the protection of people against exposure to ionizing radiation and to provide for worldwide application of these standards, the IAEA has developed the Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). The BSS was issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organisation (ILO), the OECD Nuclear Energy Agency (OECD/NEA), the Pan American Health Organization (PAHO) and the World Health Organization (WHO), and requires radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. The IAEA programme on radiation protection of patients encourages the reduction of patient doses without losing diagnostic benefits. To facilitate this

  5. CT colonography with limited bowel preparation: prospective assessment of patient experience and preference in comparison to optical colonoscopy with cathartic bowel preparation

    International Nuclear Information System (INIS)

    Jensch, Sebastiaan; Bipat, Shandra; Vries, Ayso H. de; Heutinck, Anneke; Stoker, Jaap; Peringa, Jan; Montauban van Swijndregt, Alexander D.; Dekker, Evelien; Baak, Lubbertus C.

    2010-01-01

    The purpose of this study was to prospectively compare participant experience and preference of limited preparation computed tomography colonography (CTC) with full-preparation colonoscopy in a consecutive series of patients at increased risk of colorectal cancer. CTC preparation comprised 180 ml diatrizoate meglumine, 80 ml barium and 30 mg bisacodyl. For the colonoscopy preparation 4 l of polyethylene glycol solution was used. Participants' experience and preference were compared using the Wilcoxon signed rank test and the chi-squared test, respectively. Associations between preference and experience parameters for the 173 participants were determined by logistic regression. Diarrhoea occurred in 94% of participants during CTC preparation. This side effect was perceived as severely or extremely burdensome by 29%. Nonetheless, the total burden was significantly lower for the CTC preparation than for colonoscopy (9% rated the CTC preparation as severely or extremely burdensome compared with 59% for colonoscopy; p<0.001). Participants experienced significantly more pain, discomfort and total burden with the colonoscopy procedure than with CTC (p<0.001). After 5 weeks, 69% preferred CTC, 8% were indifferent and 23% preferred colonoscopy (p<0.001). A burdensome colonoscopy preparation and pain at colonoscopy were associated with CTC preference (p<0.04). In conclusion, participants' experience and preference were rated in favour of CTC with limited bowel preparation compared with full-preparation colonoscopy. (orig.)

  6. Segmentation algorithm of colon based on multi-slice CT colonography

    Science.gov (United States)

    Hu, Yizhong; Ahamed, Mohammed Shabbir; Takahashi, Eiji; Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Suzuki, Masahiro; Iinuma, Gen; Moriyama, Noriyuki

    2012-02-01

    CT colonography is a radiology test that looks at people's large intestines(colon). CT colonography can screen many options of colon cancer. This test is used to detect polyps or cancers of the colon. CT colonography is safe and reliable. It can be used if people are too sick to undergo other forms of colon cancer screening. In our research, we proposed a method for automatic segmentation of the colon from abdominal computed Tomography (CT) images. Our multistage detection method extracted colon and spited colon into different parts according to the colon anatomy information. We found that among the five segmented parts of the colon, sigmoid (20%) and rectum (50%) are more sensitive toward polyps and masses than the other three parts. Our research focused on detecting the colon by the individual diagnosis of sigmoid and rectum. We think it would make the rapid and easy diagnosis of colon in its earlier stage and help doctors for analysis of correct position of each part and detect the colon rectal cancer much easier.

  7. Efficacy of Barium-Based Fecal Tagging for CT Colonography: a Comparison between the Use of High and Low Density Barium Suspensions in a Korean Population - a Preliminary Study

    Science.gov (United States)

    Kim, Min Ju; Lee, Seung Soo; Byeon, Jeong-Sik; Choi, Eugene K.; Kim, Jung Hoon; Kim, Yeoung Nam; Kim, Ah Young; Ha, Hyun Kwon

    2009-01-01

    Objective This preliminarily study was designed to determine and to compare the efficacy of two commercially available barium-based fecal tagging agents for CT colonography (CTC) (high-density [40% w/v] and low-density [4.6% w/v] barium suspensions) in a population in Korea. Materials and Methods In a population with an identified with an average-risk for colorectal cancer, 15 adults were administered three doses of 20 ml 40% w/v barium for fecal tagging (group I) and 15 adults were administered three doses of 200 ml 4.6% w/v barium (group II) for fecal tagging. Excluding five patients in group I and one patient in group II that left the study, ten patients in group I and 14 patients in group II were finally included in the analysis. Two experienced readers evaluated the CTC images in consensus regarding the degree of tagging of stool pieces 6 mm or larger. Stool pieces were confirmed with the use of standardized CTC criteria or the absence of matched lesions as seen on colonoscopy. The rates of complete fecal tagging were analyzed on a per-lesion and a per-segment basis and were compared between the patients in the two groups. Results Per-lesion rates of complete fecal tagging were 52% (22 of 42; 95% CI, 37.7-66.6%) in group I and 78% (28 of 36; 95% CI, 61.7-88.5%) in group II. The difference between the two groups did not reach statistical significance (p = 0.285). The per-segment rates of complete tagging were 33% (6 of 18; 95% CI, 16.1%-56.4%) in group I and 60% (9 of 15; 95% CI, 35.7%-80.3%) in group II; again, the difference between the two groups did not reach statistical significance (p = 0.171). Conclusion Barium-based fecal tagging using both the 40% w/v and the 4.6% w/v barium suspensions showed moderate tagging efficacy. The preliminary comparison did not demonstrate a statistically significant difference in the tagging efficacy between the use of the two tagging agents, despite the tendency toward better tagging with the use of the 4.6% w/v barium

  8. Effective radiation doses in CT colonography: results of an inventory among research institutions

    International Nuclear Information System (INIS)

    Jensch, Sebastiaan; Gelder, Rogier E. van; Lameris, Johan S.; Stoker, Jaap; Venema, Henk W.; Reitsma, Johannes B.; Bossuyt, Patrick M.M.

    2006-01-01

    The purpose of this study was to estimate the effective dose that is currently used in CT colonography using scan parameters that were collected for this purpose, and to investigate trends in time. PubMed was systematically searched from 1996 until January 2004 for studies investigating CT colonography. Research institutions were contacted and asked for their current scan protocol. Thirty-six institutions published 74 studies. Twenty-eight of the 36 institutions provided their current protocol. The median effective dose in 2004 was 5.1 mSv (range 1.2-11.7 mSv) per position. Most institutions (93%) scan in both the supine and prone positions. The median mAs value was 67 mAs (range 20-200), median collimation was 2.5 mm (range 0.75-5). From 1996 until 2004 a significant decrease in mAs and collimation (P=0.006, P<0.0001, respectively) was observed, while institutions that used a multislice scanner increased (P<0.0001). The effective dose remained constant (P=0.76). In 2004 the median effective dose for a complete CT colonography was 10.2 mSv. Despite the increasing use of multislice scanners, which are slightly less dose-efficient, the median effective dose remained approximately constant between 1996 and 2004. This is mainly caused by the use of lower mAs settings. (orig.)

  9. CT colonography: colonic distention improved by dual positioning but not intravenous glucagon

    International Nuclear Information System (INIS)

    Morrin, Martina M.; Keogan, Mary T.; Kruskal, Jonathan B.; Yam, Chun-Shan; Raptopoulos, Vassilios; Farrell, Richard J.

    2002-01-01

    The aim of this study was to determine whether intravenous (IV) glucagon and dual positioning administered prior to CT colonography enhances colonic distention. We assessed the effect of dual positioning and IV glucagon on colonic distention in 96 patients who underwent CT colonography examinations. The CT colonography was performed in both supine and prone positions. Seventy-four patients received glucagon (1 mg i.v.) immediately prior to CT scanning and 22 patients did not. The bowel was divided into ten segments and colonic distention was scored by two radiologists in the supine, prone, and combined supine/prone positions using a five-point scale: 1=collapsed; 2=poorly visualized; ≥3=adequate distention; 4=entire segment visualized and well distended; 5=excellent distention. A combined segmental and overall supine/prone distention score was calculated based on the sum of the mean score for each position. There was no significant difference in the degree of colonic distention between patients who received glucagon and those who did not [supine/prone distention score (mean±SE): 3.63±0.2 vs 3.85±0.2; p=n.s.]. The degree of colonic distention was greater in the prone position in both the glucagon (3.87±0.2 vs 3.38±0.2; p<0.05) and non-glucagon groups (4.01±0.2 vs 3.69±0.2; p=N.S.) particularly in the proximal colon. There was almost perfect agreement between both radiologists in their scoring of colonic distention on a per-patient basis (k=0.9; p<0.001). Of 1480 bowel segments, 1261 (85.2%) were adequately distended in the glucagon group compared with 370 of 440 bowel segments (84%) in the non-glucagon group (p=n.s.) Colonic distention at CT colonography is improved by dual positioning but not by the administration of intravenous glucagon. While our results suggest that other smooth muscle relaxants, including butyl scopolamine, may only have a limited role in improving colonic distention in CT colonography, further studies are required. (orig.)

  10. Current status of MR colonography.

    LENUS (Irish Health Repository)

    Thornton, Eavan

    2010-01-01

    The search for an acceptable colorectal cancer screening examination has led to the development of virtual colonoscopy, which includes both computed tomographic (CT) colonography and magnetic resonance (MR) colonography. As indicated by the much larger number of published studies on CT colonography than on MR colonography, multidetector CT appears to be more suitable for colorectal screening than does MR colonography, in part reflecting the ease and speed of performing CT, as well as the increased spatial resolution, decreased cost, and wider availability of CT colonography. The main advantage of MR colonography over CT colonography is that it does not use ionizing radiation, which has important implications for colorectal cancer screening. The use of dark-lumen MR colonography to screen patients for colorectal cancer as well as other abdominopelvic disease could make it more attractive than CT. With the integration of 3.0-T MR colonography, fecal tagging, and parallel imaging into research and clinical settings, new MR colonography protocols must be optimized. Future MR colonography research should address issues such as image characteristics, presence of artifacts, management of specific absorption rate, and hardware-related modifications.

  11. Utility of minimal preparation ct colonography in detecting colorectal cancer in elderly and frail patients.

    Science.gov (United States)

    Meiklejohn, D J; Ridley, L J; Ngu, M C; Cowlishaw, J L; Duller, A; Ridley, W

    2018-06-11

    Colorectal cancers result in substantial morbidity and mortality to Australian society each year. The usual investigation for bowel malignancyis optical colonoscopy (OC), withcomputed tomographic colonography (CTC) used as an alternative investigation. The catharsis and colon insufflation associated with these investigations pose a higher risk in the elderly and frail. Risks include perforation, serum electrolyte disturbance, and anaesthesia/sedation risks.Minimal preparation computed tomographic colonography (MPCTC) eliminates these risks. This paper audits a 6-year period ofMPCTC in an Australian tertiary referral hospital. 145 patients underwent MPCTC during the study period. There were 7 true positives, 2 false positives and 2 false negatives. Analysis of this population indicates a sensitivity of 0.78 (95% CI 0.51 - 1.05), specificity of 0.99 (95% CI 0.97 - 1.01), positive predictive value (PPV) of 0.78 (95% CI 0.51 - 1.05) and negative predictive value (NPV) of 0.99 (95% CI 0.97 - 1.01). These findings are concordant with other published studies. The auditconfirmsthatminimal preparation CT colonography is a reasonable alternative to OC and CTC in detecting colorectal cancer in symptomatic elderly and frail patients, without the procedural risks inherent inmore invasive investigations. For most patients MPCTC ruled out significant colorectal carcinoma with a high negative predictive value. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  12. Present status and future view on virtual endoscopy. Depiction of minute lesions in the large intestine with CT colonography

    International Nuclear Information System (INIS)

    Sugino, Yoshinori

    2002-01-01

    CT colonography is a new imaging technique using helical CT. We studied the efficacy of CT colonoscopy in the detection of small polyps and depiction of superficial lesions. Concerning the detection of small polyps, we studied 54 patients with abnormality checked by barium enema. Conventional colonoscopy revealed 79 lesions (5 advanced carcinomas, 4 superficial-type adenomas and 70 polyps). CT colonography identified all 5 carcinomas, 3 of the 4 superficial lesions and 43 of the 45 polyps that were 0.5 cm or smaller in diameter, 18 of 22 polyps that were 0.6 to 0.9 cm, and all 3 polyps that were 1.0 cm or more in diameter. There were 92 false positive polyps that were 0.5 cm or smaller in diameter. On a superficial lesion, we could depict a superficial depressive type early colonic carcinoma 1.0 cm in diameter, using very thin-slice CT equipment. In conclusion, CT colonography has a high sensitivity for detection of small polyps and sufficient capability for depiction of superficial lesions. CT colonography may be suitable for screening examinations of the large intestine. (author)

  13. CT colonography: Diagnostic role of contrast enhancement of benign polyps and colorectal carcinoma

    International Nuclear Information System (INIS)

    Stoinova, V.; Nedevska, M.

    2006-01-01

    Full text: The aim of this study was to compare pre- and postcontrast CT attenuation values of benign colorectal polyps and carcinoma lesions detected by CT colonography, and to investigate whether contrast enhancement of these lesions can be potentially used for differentiation from residual fluid and feces. We retrospectively reviewed CT colonographic dataset of 120 patients. 35 benign polyps and 22 colorectal carcinomas were included in our study. All lesions were confirmed by colonoscopic biopsy or surgery. The difference in attenuation value between precontrast and postcontrast studies of polyps was statistically significant; the same was true for colorectal cancers. In the precontrast phase no statistically significant difference was observed between stool, polyps and cancers. The mean attenuation value of solid fecal residuals was 37 HU before and after contrast enhancement. Residual fluid do not take up contrast and the density does not change in the contrast-enhanced phase. The difference between postcontrast density of polyps and cancers with respect to density of stools and residual fluid was significant. The use of contrast medium could be helpful in CT colonography for discriminating polypoid benign lesions and colorectal cancer from fecal and fluid residuals

  14. Colon distension and scan protocol for CT-colonography: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, Thierry N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Haan, Margriet C. de, E-mail: m.c.dehaan@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Venema, Henk W., E-mail: h.w.venema@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Department of Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands); Stoker, Jaap, E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center, University of Amsterdam, PB 22660, 1100 DD Amsterdam (Netherlands)

    2013-08-15

    This article reviews two important aspects of CT-colonography, namely colonic distension and scan parameters. Adequate distension should be obtained to visualize the complete colonic lumen and optimal scan parameters should be used to prevent unnecessary radiation burden. For optimal distension, automatic carbon dioxide insufflation should be performed, preferably via a thin, flexible catheter. Hyoscine butylbromide is – when available – the preferred spasmolytic agent because of the positive effect on insufflation and pain/burden and its low costs. Scans in two positions are required for adequate distension and high polyp sensitivity and decubitus position may be used as an alternative for patients unable to lie in prone position. The great intrinsic contrast between air or tagging and polyps allows the use of low radiation dose. Low-dose protocol without intravenous contrast should be used when extracolonic findings are deemed unimportant. In patients suspected for colorectal cancer, normal abdominal CT scan protocols and intravenous contrast should be used in supine position for the evaluation of extracolonic findings. Dose reduction can be obtained by lowering the tube current and/or voltage. Tube current modulation reduces the radiation dose (except in obese patients), and should be used when available. Iterative reconstructions is a promising dose reducing tool and dual-energy CT is currently evaluated for its applications in CT-colonography. This review also provides our institution's insufflation procedure and scan parameters.

  15. CAD for CT colonography: toward a preparation-independent scheme

    International Nuclear Information System (INIS)

    Naeppi, J.

    2007-01-01

    Computer-aided detection (CAD) systems can be used to automatically detect and display the locations of polyps and masses in computed tomographic colonography (CTC) data for assisting radiologists' image interpretation. Rapid technical advancements over the last few years have established a fundamental CAD scheme for CTC that includes the steps of colon extraction, polyp detection, and false-positive (FP) reduction. Several CAD prototype systems have demonstrated clinically acceptable high polyp detection sensitivity with relatively few FP detections in cathartic CTC, and observer studies have demonstrated the potential benefit of such systems in improving the accuracy and consistency of radiologists' detection performance. Some CAD prototype systems have also demonstrated promising performance in reduced cathartic and non-cathartic CTC. Recent advancements suggest that CAD systems can soon be expected to provide a preparation-independent scheme that can yield consistently high detection sensitivity with moderately low FP rate not only with cathartic CTC protocols but over a wide range of cathartic, reduced cathartic, and non-cathartic CTC protocols. (orig.)

  16. Reader error during CT colonography: causes and implications for training

    International Nuclear Information System (INIS)

    Slater, Andrew; Tam, Emily; Gartner, Louise; Scarth, Julia; Peiris, Chand; Gupta, Arun; Marshall, Michele; Burling, David; Taylor, Stuart A.; Halligan, Steve

    2006-01-01

    This study investigated the variability in baseline computed tomography colonography (CTC) performance using untrained readers by documenting sources of error to guide future training requirements. Twenty CTC endoscopically validated data sets containing 32 polyps were consensus read by three unblinded radiologists experienced in CTC, creating a reference standard. Six readers without prior CTC training [four residents and two board-certified subspecialty gastrointestinal (GI) radiologists] read the 20 cases. Readers drew a region of interest (ROI) around every area they considered a potential colonic lesion, even if subsequently dismissed, before creating a final report. Using this final report, reader ROIs were classified as true positive detections, true negatives correctly dismissed, true detections incorrectly dismissed (i.e., classification error), or perceptual errors. Detection of polyps 1-5 mm, 6-9 mm, and ≥10 mm ranged from 7.1% to 28.6%, 16.7% to 41.7%, and 16.7% to 83.3%, respectively. There was no significant difference between polyp detection or false positives for the GI radiologists compared with residents (p=0.67, p=0.4 respectively). Most missed polyps were due to failure of detection rather than characterization (range 82-95%). Untrained reader performance is variable but generally poor. Most missed polyps are due perceptual error rather than characterization, suggesting basic training should focus heavily on lesion detection. (orig.)

  17. Implementation of a new CT colonography service: 5 Year experience

    International Nuclear Information System (INIS)

    Lung, P.F.C.; Burling, D.; Kallarackel, L.; Muckian, J.; Ilangovan, R.; Gupta, A.; Marshall, M.; Shorvon, P.; Halligan, S.; Bhatnagar, G.; Bassett, P.; Taylor, S.A.

    2014-01-01

    Aim: To describe our experience using a 5 year audit of computed tomography colonography (CTC) practice and identify factors that influence diagnostic performance to guide implementation in other centres. Material and methods: Consecutive patients referred for CTC at a single institution over a 5 year period were identified, and reporting rates and positive predictive value (PPV) calculated for small polyps, large polyps, and colorectal cancer. Diagnostic performance was compared using the Chi-squared test, and trends over time were examined with logistic regression. The effect of faecal tagging and an intravenous spasmolytic were investigated using Fisher's exact test. Results: In total, 4355 CTC examinations were performed. Overall reporting rates and PPV were 17% and 92%, respectively. Negative predictive value (NPV) for cancer was 99.9%. A significant decrease in reporting rate (p < 0.001) was accompanied by an increase in PPV for small polyps (p = 0.02) following the introduction of faecal tagging. Adequacy rates for CTC improved over time (96% to 99%), with improved adequacy rates when using a spasmolytic, 98% versus 96% without. A significant difference in reporting rates, but not PPV, was found between radiologists. Conclusion: Accurate colonic investigation using CTC can be delivered safely to a high-risk patient population at a single centre. Faecal tagging and an intravenous spasmolytic improve diagnostic performance

  18. CT colonography training for radiographers - a formal evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Haycock, A. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Burling, D., E-mail: burlingdavid@yahoo.co.u [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom); Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S. [Intestinal Imaging Centre and Wolfson Unit for Endoscopy, St Mark' s Hospital, Imperial College London, London (United Kingdom)

    2010-12-15

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p < 0.001. Correct classification of CTC examination improved significantly from a mean of 55% pre-course to 71% post-course, p < 0.001. Cancer and large polyp (>10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  19. CT colonography training for radiographers - a formal evaluation

    International Nuclear Information System (INIS)

    Haycock, A.; Burling, D.; Wylie, P.; Muckian, J.; Ilangovan, R.; Thomas-Gibson, S.

    2010-01-01

    Aims: To evaluate the efficacy of a new intensive 'hands-on' course designed to train small teams of radiographers in computed tomography colonography (CTC) technique and initial interpretation for patient triage. Materials and methods: The course comprised small-group lectures, active participation in the daily CTC service with practical technique and image interpretation training by experienced radiologists and radiographers. Evaluation was by assessment of knowledge using randomized sets of multiple choice questions (MCQ; pre/post-course), practical technique using checklists and expert global scores, and interpretation performance outcomes using randomized pre/post-course test datasets (five validated CTC examinations each). Paired t-tests were used to investigate change in performance for MCQ score and interpretation accuracy. Results: Thirteen courses with 49 participants were evaluated over 2 years. Practical skills were high, with mean (SD) checklist scores of 14/15 (0.85) and global scores of 26/30 (2.3). MCQ scores increased significantly from a mean of 59% pre-course to 69% post-course, p 10 mm) detection rates also improved significantly from 49% to 60%, p = 0.002. Conclusion: Structured training in CTC can significantly improve knowledge and interpretation skills of radiographers, while assessing safe procedural performance. Implementation of similar programmes nationally may help reduce performance gaps between centres.

  20. Evaluation of dose exposure in 64-slice CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M. [University Hospital Tuebingen, Department of Diagnostic Radiology, Tuebingen (Germany); Buchgeister, M.; Klabunde, M. [University of Tuebingen, Institute of Medical Physics, Tuebingen (Germany)

    2007-10-15

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  1. Evaluation of dose exposure in 64-slice CT colonography

    International Nuclear Information System (INIS)

    Luz, O.; Trabold, T.; Kopp, A.F.; Claussen, C.D.; Heuschmid, M.; Buchgeister, M.; Klabunde, M.

    2007-01-01

    The radiation exposure of four different 64-slice MDCT-colonography (CTC) protocols was evaluated using an Alderson-Rando phantom. Protocols using 30 mAs (collimation 20 x 1.2mm), 50 mAs (collimation 20 x 1.2 and 64 x 0.6mm) and 80 mAs (20 x 1.2 mm) representing screening low-dose, routine, narrow collimation and oncologic staging setups were measured with an Alderson-Rando phantom (Alderson Research Laboratories Inc.). Scans were performed on a 64-row MDCT (SOMATOM Sensation 64, Siemens) simulating the prone and supine positions with a constant voltage of 120 kV. Dose values (male/female) were 2.5/2.9, 3.8/4.2, 4.2/4.5 and 5.7/6.4 mSv for 30, 50 (20 x 1.2 and 64 x 0.6 mm) and 80 mAs, respectively. Measurements showed an elevated dose for females (11.5% mean; compared to males). Use of narrow collimation combined with 50 mAs resulted in a small increase of dose exposure of 10.5 (male) and 7.1% (female). Gonad doses ranged from 0.9 to 2.6 mSv (male) and from 1.5 to 3.5 mSv (female). In all protocols, the stomach wall, lower colon, urinary bladder and liver were slightly more highly exposed (all <2.3 mSv) than the other organs, and the breast dose was <0.3 mSv in every setup. Values of radiation exposure in 64- and 16-slice CTC differ only marginally when using the narrow collimation. In 64-slice CTC, the use of narrow (64 x 0.6 mm) collimation shows slightly elevated dose values compared to wider (20 x 1.2 mm) collimation. (orig.)

  2. Business plan to establish a CT colonography service.

    Science.gov (United States)

    Fajardo, Laurie L; Hurley, James P; Brown, Bruce P; Summers, Robert W; McDaniel, R Donald

    2006-03-01

    The authors describe the University of Iowa Department of Radiology's business planning process to initiate a new service in computed tomographic colonography (CTC). Also known as virtual colonoscopy, CTC is a noninvasive technology that offers less risk, and potentially similar sensitivity and specificity, than conventional optical colonoscopy (OC). Although not currently covered by all insurance payers, about a year ago, the Centers for Medicare and Medicaid Services instituted temporary Current Procedural Terminology codes (Category III) for CTC. In locales where the procedure is not covered by insurers, it is likely to be sought by patients willing to pay out of pocket to undergo noninvasive cancer screening as an alternative to OC. Thus, CTC could become the preferred method of colon cancer surveillance by insurance providers in the near future. In developing the business plan, the authors reviewed pertinent scientific and clinical data to evaluate the need for and efficacy of CTC. Local market data were used to estimate patient and procedure volumes and utilization. The authors modeled financial expectations with respect to return on investment on the basis of recently reported models specific to CTC, resource requirements, and the operational impact of the new service on existing hospital and departmental clinical functions. Because there are few local providers of CTC in the authors' region, the business plan also included a publicity campaign and plan to market the new service, stimulate general public interest early, and differentiate the program as a leader in applying this unique new technology to promote cancer screening. Finally, the planning committee acknowledged and accommodated needs specific to the missions of an academic medical center with respect to research and education in designing the new service.

  3. Image quality and patient acceptance of four regimens with different amounts of mild laxatives for CT colonography

    NARCIS (Netherlands)

    Jensch, Sebastiaan; de Vries, Ayso H.; Pot, Dennis; Peringa, Jan; Bipat, Shandra; Florie, Jasper; van Gelder, Rogier E.; Stoker, Jaap

    2008-01-01

    OBJECTIVE: The purpose of our study was to prospectively evaluate image quality and patient acceptance of CT colonography (CTC) with fecal tagging using different levels of catharsis. SUBJECTS AND METHODS: Forty consecutive increased-risk patients were randomized. Group 1 received orally 20 mg of

  4. CT colonography: Project of High National Interest No. 2005062137 of the Italian Ministry of Education, University and Research (MIUR).

    Science.gov (United States)

    Neri, E; Laghi, A; Regge, D; Sacco, P; Gallo, T; Turini, F; Talini, E; Ferrari, R; Mellaro, M; Rengo, M; Marchi, S; Caramella, D; Bartolozzi, C

    2008-12-01

    The aim of this paper is to describe the Web site of the Italian Project on CT Colonography (Research Project of High National Interest, PRIN No. 2005062137) and present the prototype of the online database. The Web site was created with Microsoft Office Publisher 2003 software, which allows the realisation of multiple Web pages linked through a main menu located on the home page. The Web site contains a database of computed tomography (CT) colonography studies in the Digital Imaging and Communications in Medicine (DICOM) standard, all acquired with multidetector-row CT according to the parameters defined by the European Society of Abdominal and Gastrointestinal Radiology (ESGAR). The cases present different bowel-cleansing and tagging methods, and each case has been anonymised and classified according to the Colonography Reporting and Data System (C-RADS). The Web site is available at http address www.ctcolonography.org and is composed of eight pages. Download times for a 294-Mbyte file were 33 min from a residential ADSL (6 Mbit/s) network, 200 s from a local university network (100 Mbit/s) and 2 h and 50 min from a remote academic site in the USA. The Web site received 256 accesses in the 22 days since it went online. The Web site is an immediate and up-to-date tool for publicising the activity of the research project and a valuable learning resource for CT colonography.

  5. Low-Fiber Diet in Limited Bowel Preparation for CT Colonography: Influence on Image Quality and Patient Acceptance

    NARCIS (Netherlands)

    Liedenbaum, Marjolein H.; Denters, Maaike J.; de Vries, Ayso H.; van Ravesteijn, Vincent F.; Bipat, Shandra; Vos, Frans M.; Dekker, Evelien; Stoker, Jaap

    2010-01-01

    OBJECTIVE. The purpose of this study was to determine whether a low-fiber diet is necessary for optimal tagging-only bowel preparation for CT colonography. SUBJECTS AND METHODS. Fifty consecutively enrolled patients received an iodine bowel preparation: 25 patients used a low-fiber diet and 25 used

  6. Virtual colonoscopy (CT colonography) in the identification of colorectal cancer. A prospective study in symptomatic patients

    International Nuclear Information System (INIS)

    Regge, D.; Martincich, L.; Gallo, T.; Pollone, M.; Galatola, G.; Secreto, P.; Pera, A.; Rivolta, A.

    2000-01-01

    Aim of this study was to evaluate the sensitivity of virtual colonoscopy (CT colonography) in the identification of colorectal cancer and to define the limitations and the advantages of this imaging modality, as well as indications to the examination. It was examined prospectively 62 symptomatic patients aged 36 to 82 years (28 women and 34 men). All patients underwent both conventional and virtual colonoscopy on the same day; the conventional examination allowed exploration of the entire colon. Conventional colonoscopy identified 89 lesions 3-50 mm in diameter, namely 84 benign and 5 malignant lesions. No lesions were identified in 12 patients. CT colonography identified 52 of the 89 lesions, with 57.1% diagnostic accuracy. They were 11 false positives (82.5% positive predictive value and 52.2% specificity) and 37 false negatives (24.5% negative predictive value and 58.4% sensitivity). Sensitivity was significantly higher (85.7%) for polyps ≥ 1 cm. Virtual colonoscopy is an imaging modality with good diagnostic yield, well tolerated by patients and with great potentials for further development. It was suggested that the examination be performed in symptomatic patients who cannot undergo total colonoscopy or refuse the other imaging modalities. Further studies are waranted in larger series of patients, possibly introducing it in screening programs [it

  7. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lefere, Philippe, E-mail: radiologie@skynet.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Silva, Celso, E-mail: caras@uma.pt [Human Anatomy of Medical Course, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Gryspeerdt, Stefaan, E-mail: stefaan@sgryspeerdt.be [VCTC, Virtual Colonoscopy Teaching Centre, Akkerstraat 32c, B-8830 Hooglede (Belgium); Rodrigues, António, E-mail: nucleo@nid.pt [Nucleo Imagem Diagnostica, Rua 5 De Outubro, 9000-216 Funchal (Portugal); Vasconcelos, Rita, E-mail: rita@uma.pt [Department of Engineering and Mathematics, University of Madeira, Praça do Município, 9000-082 Funchal (Portugal); Teixeira, Ricardo, E-mail: j.teixeira1947@gmail.com [Department of Gastroenterology, Central Hospital of Funchal, Avenida Luís de Camões, 9004513 Funchal (Portugal); Gouveia, Francisco Henriques de, E-mail: fhgouveia@netmadeira.com [LANA, Pathology Centre, Rua João Gago, 10, 9000-071 Funchal (Portugal)

    2013-06-15

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer.

  8. Teleradiology based CT colonography to screen a population group of a remote island; at average risk for colorectal cancer

    International Nuclear Information System (INIS)

    Lefere, Philippe; Silva, Celso; Gryspeerdt, Stefaan; Rodrigues, António; Vasconcelos, Rita; Teixeira, Ricardo; Gouveia, Francisco Henriques de

    2013-01-01

    Purpose: To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer. Materials and methods: A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm. Results: 510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively. Conclusion: In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer

  9. CT colonography at low tube potential: using iterative reconstruction to decrease noise

    International Nuclear Information System (INIS)

    Chang, K.J.; Heisler, M.A.; Mahesh, M.; Baird, G.L.; Mayo-Smith, W.W.

    2015-01-01

    Aim: To determine the level of iterative reconstruction required to reduce increased image noise associated with low tube potential computed tomography (CT). Materials and methods: Fifty patients underwent CT colonography with a supine scan at 120 kVp and a prone scan at 100 kVp with other scan parameters unchanged. Both scans were reconstructed with filtered back projection (FBP) and increasing levels of adaptive statistical iterative reconstruction (ASiR) at 30%, 60%, and 90%. Mean noise, soft tissue and tagged fluid attenuation, contrast, and contrast-to-noise ratio (CNR) were collected from reconstructions at both 120 and 100 kVp and compared using a generalised linear mixed model. Results: Decreasing tube potential from 120 to 100 kVp significantly increased image noise by 30–34% and tagged fluid attenuation by 120 HU at all ASiR levels (p<0.0001, all measures). Increasing ASiR from 0% (FBP) to 30%, 60%, and 90% resulted in significant decreases in noise and increases in CNR at both tube potentials (p<0.001, all comparisons). Compared to 120 kVp FBP, ASiR greater than 30% at 100 kVp yielded similar or lower image noise. Conclusions: Iterative reconstruction adequately compensates for increased image noise associated with low tube potential imaging while improving CNR. An ASiR level of approximately 50% at 100 kVp yields similar noise to 120 kVp without ASiR. -- Highlights: •Peak kilovoltage (kVp) can be reduced to decrease radiation dose and increase contrast attenuation at a cost of increased image noise. •Utilizing iterative reconstruction can decrease image noise and increase contrast to noise ratio (CNR) independent of kVp. •Iterative reconstruction adequately compensates for increased image noise associated with low dose low kVp imaging while improving CNR. •An ASiR level of approximately 50% at 100 kVp yields similar noise to 120 kVp without ASiR

  10. Colon distension, perceived burden and side-effects of CT-colonography for screening using hyoscine butylbromide or glucagon hydrochloride as bowel relaxant

    NARCIS (Netherlands)

    de Haan, Margriet C.; Boellaard, Thierry N.; Bossuyt, Patrick M.; Stoker, Jaap

    2012-01-01

    Objective: Compare colonic distension and perceived burden of CT-colonography between participants receiving hyoscine butylbromide (buscopan) and glucagon hydrochloride as bowel relaxant. Materials and methods: Data were collected within a screening trial. Participants received 20 mg buscopan

  11. CT-colonography in population-based colorectal cancer screening

    NARCIS (Netherlands)

    de Haan, M.C.

    2012-01-01

    In een proefbevolkingsonderzoek naar dikkedarmkanker vergeleek Margriet de Haan coloscopie (onderzoek met een dunne flexibele slang met camera om de darm van binnenuit te bekijken) met CT-colografie (onderzoek waarbij de darmen worden onderzocht zonder slang) wat betreft opkomst, opbrengst,

  12. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  13. Computer-aided detection in CT colonography: initial clinical experience using a prototype system

    International Nuclear Information System (INIS)

    Graser, A.; Geisbuesch, S.; Reiser, M.F.; Becker, C.R.; Kolligs, F.T.; Schaefer, C.; Mang, T.

    2007-01-01

    Computer-aided detection (CAD) algorithms help to detect colonic polyps at CT colonography (CTC). The purpose of this study was to evaluate the accuracy of CAD versus an expert reader in CTC. One hundred forty individuals (67 men, 73 women; mean age, 59 years) underwent screening 64-MDCT colonography after full cathartic bowel cleansing without fecal tagging. One expert reader interpreted supine and prone scans using a 3D workstation with integrated CAD used as ''second reader.'' The system's sensitivity for the detection of polyps, the number of false-positive findings, and its running time were evaluated. Polyps were classified as small (≤5 mm), medium (6-9 mm), and large (≥10 mm). A total of 118 polyps (small, 85; medium, 19; large, 14) were found in 56 patients. CAD detected 72 polyps (61%) with an average of 2.2 false-positives. Sensitivity was 51% (43/85) for small, 90% (17/19) for medium, and 86% (12/14) for large polyps. For all polyps, per-patient sensitivity was 89% (50/56) for the radiologist and 73% (41/56) for CAD. For large and medium polyps, per-patient sensitivity was 100% for the radiologist, and 96% for CAD. In conclusion, CAD shows high sensitivity in the detection of clinically significant polyps with acceptable false-positive rates. (orig.)

  14. Evaluation of colonic lesions and pitfalls in CT colonography: A systematic approach based on morphology, attenuation and mobility

    International Nuclear Information System (INIS)

    Mang, Thomas; Gryspeerdt, Stefaan; Schima, Wolfgang; Lefere, Philippe

    2013-01-01

    Computed tomographic colonography is a reliable technique for the detection and classification of neoplastic and non-neoplastic lesions of the colon. It is based on a thin-section CT dataset of the cleansed and air-distended colon, acquired in prone and supine position. Two-dimensional and 3D projections are used in combination for image interpretation. The evaluation of CT colonography datasets is based on two steps, lesion perception to detect a polyp candidate and image interpretation to correctly characterize colonic filling defects. A thorough knowledge of the morphologic and attenuation characteristics of common colonic lesions and artifacts facilitates characterization of the findings. The purpose of this review article is to give an overview of the key CT colonographic imaging criteria to correctly characterize common colorectal lesions and to identify typical pitfalls and pseudolesions

  15. CT colonography after colostomy - clinical application and technical feasibility

    International Nuclear Information System (INIS)

    Nedevska, A.

    2013-01-01

    Full text:Introduction: The aim of this study was to evaluate the clinical application and technical implementation of computed tomographic (CT ) colonoscopy in patients undergoing sigmoid or rectal resection and following sigmoid colostomy in the course of standard diagnostic postoperative follow-up and prior to the reconstructive colon surgery. Materials and Methods: The study included 48 patients who underwent anterior abdomen-perineal or rectal resection and subsequent sigmoid colostomy in case of sigma or rectum carcinoma. The pre-procedure bowel preparation included a full colon cleansing and barium-based fecal tagging. The balloon catheter (18 F) is placed in the colonic stoma. The balloon is insufflated with 15-30 ml saline or air. The balloon was gently pulled until opening of the stoma has been closed completely. In 15 patients, a second catheter was placed in the remaining rectum. Contrast scanning in supination was done for all patients. An additional scanning in left and right lateral position was necessary for 9 patients. Results: All studies were carried out without any major complications. All patients tolerated the intubation and insufflation of air into the intestinal lumen. Two patients (4%) have evaluated the examination as uncomfortable. In 6 patients (12.5 %) it was impossible to evaluate the intestinal segments because due to a collapse of the wall. Five of them were localized in the descending colon. In 5 patients there was a significant amount of residual intestinal contents. The fecal tagging and intravenous contrast enhancing allowed the assessment of these intestinal segments. The rectal residue was correctly assessed in all patients in terms of length, position and wall changes. Conclusion: CT colonoscopy is applicable after sigmostoma in patients with abdomen-perineal and anterior rectal resection. Further in-depth studies are needed to determine the clinical indications and reliability of the method

  16. Effect of a tele-training programme on radiographers in the interpretation of CT colonography

    DEFF Research Database (Denmark)

    Lauridsen, Carsten; Lefere, Philippe; Gerke, Oke

    2012-01-01

    OBJECTIVE: To assess the performance of radiographers in CT colonography (CTC) after a tele-training programme, supervised by 2 experienced radiologists. MATERIALS AND METHODS: Five radiographers underwent training in CTC using a tele-training programme mainly based on the interpretation of 75...... training cases performed in the novice department. To evaluate the educational performance, each radiographer was tested on 20 test cases with 27 lesions >6mm (12: 6-9mm; 15: >10mm). Sensitivity, specificity and PPV for polyps ≥6mm and ≥10mm were calculated with point estimates and 95% confidence interval...... (95% CI). The results were compared by comparing 95% CI with a 5% significance level. RESULTS: In the training cases overall per-polyp sensitivity was 57% (95% CI 46.1-67.9) and 69.1% (95% CI 50.6-87.5) for lesions ≥6mm and ≥10mm, respectively. Overall per patient sensitivity, specificity and PPV were...

  17. PET/CT colonography in patients with colorectal polyps: a feasibility study

    International Nuclear Information System (INIS)

    Mainenti, Pier P.; Pace, Leonardo; Salvatore, Marco; Salvatore, Barbara; D'Antonio, Dario; Bucci, Luigi; De Falco, Teresa; De Palma, Giovanni D.; D'Armiento, Francesco P.

    2007-01-01

    To examine: (1) the feasibility of PET/CT colonography (PET/CTc) in patients with colorectal polyps; (2) the impact of metabolic information on CTc interpretation and, conversely, the impact of morphological information on PET characterisation of focal colorectal uptake. Ten patients with colorectal polyps underwent PET/CTc, followed within 3 h by therapeutic conventional colonoscopy (CC). A radiologist and a nuclear medicine physician analysed the PET/CTc images. The agreement of morphological and metabolic information in the colon and rectum was evaluated. The sensitivity and specificity of PET, CT and PET/CT were calculated for colorectal polyps. Seventeen polypoid lesions were identified at CC: six≤5 mm, six between 6 and 9 mm, and five ≥10 mm (four hyperplastic polyps, 11 tubular adenomas, one adenocarcinoma and one submucosal lipoma). A total of 20 scans (supine and prone) were performed in the ten patients: the agreement of morphological and metabolic information was excellent in 17 scans, good in two and moderate in one. PET/CTc showed a sensitivity of 91% for lesions ≥6 mm and a specificity of 100%. The metabolic information did not disclose any further polyps missed on CTc. The morphological information permitted correct classification of all eight instances of focal radiotracer uptake. PET/CTc is a feasible study. Adding a colonographic protocol to PET/CT images seems to allow correct characterisation of all cases of colorectal focal radiotracer uptake. The metabolic information does not seem to increase the accuracy of CTc. (orig.)

  18. Comparative economic evaluation of data from the ACRIN National CT Colonography Trial with three cancer intervention and surveillance modeling network microsimulations.

    Science.gov (United States)

    Vanness, David J; Knudsen, Amy B; Lansdorp-Vogelaar, Iris; Rutter, Carolyn M; Gareen, Ilana F; Herman, Benjamin A; Kuntz, Karen M; Zauber, Ann G; van Ballegooijen, Marjolein; Feuer, Eric J; Chen, Mei-Hsiu; Johnson, C Daniel

    2011-11-01

    To estimate the cost-effectiveness of computed tomographic (CT) colonography for colorectal cancer (CRC) screening in average-risk asymptomatic subjects in the United States aged 50 years. Enrollees in the American College of Radiology Imaging Network National CT Colonography Trial provided informed consent, and approval was obtained from the institutional review board at each site. CT colonography performance estimates from the trial were incorporated into three Cancer Intervention and Surveillance Modeling Network CRC microsimulations. Simulated survival and lifetime costs for screening 50-year-old subjects in the United States with CT colonography every 5 or 10 years were compared with those for guideline-concordant screening with colonoscopy, flexible sigmoidoscopy plus either sensitive unrehydrated fecal occult blood testing (FOBT) or fecal immunochemical testing (FIT), and no screening. Perfect and reduced screening adherence scenarios were considered. Incremental cost-effectiveness and net health benefits were estimated from the U.S. health care sector perspective, assuming a 3% discount rate. CT colonography at 5- and 10-year screening intervals was more costly and less effective than FOBT plus flexible sigmoidoscopy in all three models in both 100% and 50% adherence scenarios. Colonoscopy also was more costly and less effective than FOBT plus flexible sigmoidoscopy, except in the CRC-SPIN model assuming 100% adherence (incremental cost-effectiveness ratio: $26,300 per life-year gained). CT colonography at 5- and 10-year screening intervals and colonoscopy were net beneficial compared with no screening in all model scenarios. The 5-year screening interval was net beneficial over the 10-year interval except in the MISCAN model when assuming 100% adherence and willingness to pay $50,000 per life-year gained. All three models predict CT colonography to be more costly and less effective than non-CT colonographic screening but net beneficial compared with no

  19. PET/CT colonography: a novel non-invasive technique for assessment of extent and activity of ulcerative colitis

    Energy Technology Data Exchange (ETDEWEB)

    Das, Chandan J.; Sharma, Raju [All India Institute of Medical Sciences, Department of Radiodiagnosis, New Delhi (India); Makharia, Govind K.; Tiwari, Rajeew P. [All India Institute of Medical Sciences, Department of Gastroenterology and Human Nutrition, New Delhi (India); Kumar, Rakesh; Kumar, Rajender; Malhotra, Arun [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India)

    2010-04-15

    Extent of involvement and activity of ulcerative colitis (UC) is best evaluated by colonoscopy. Colonoscopy however carries risk during acute exacerbation. We investigated the utility of PET/CT colonography for assessment of extent and activity of UC. Within a 1-week window, 15 patients with mild to moderately active UC underwent colonoscopy and PET/CT colonography 60 min after injection of 10 mCi of {sup 18}F-fluorodeoxyglucose (FDG). PET activity score based on the amount of FDG uptake and endoscopic mucosal activity in seven colonic segments of each patient was recorded. The mean maximum standardized uptake value (SUV{sub max}) of seven segments was compared with activity in liver. A PET activity grade of 0, 1, 2 or 3 was assigned to each region depending upon their SUV{sub max} ratio (colon segment to liver). The extent of disease was left-sided colitis in five and pancolitis in ten. The mean Ulcerative Colitis Disease Activity Index (UCDAI) was 7.6. The number of segments involved as per colonoscopic evaluation and PET/CT colonography was 67 and 66, respectively. There was a good correlation for extent evaluation between the two modalities (kappa 55.3%, p = 0.02). One patient had grade 0 PET activity, nine had grade 2 and five had grade 3 PET activity. In six patients, there was one to one correlation between PET activity grades with that of endoscopic grade. One patient showed activity in the sacroiliac joint suggesting active sacroiliitis. PET/CT colonography is a novel non-invasive technique for the assessment of extent and activity of the disease in patients with UC. (orig.)

  20. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  1. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  2. Diagnostic value of CT-colonography as compared to colonoscopy in an asymptomatic screening population: a meta-analysis

    International Nuclear Information System (INIS)

    Haan, Margriet C. de; Gelder, Rogier E. van; Bipat, Shandra; Stoker, Jaap; Graser, Anno

    2011-01-01

    Previous meta-analyses on CT-colonography included both average and high risk individuals, which may overestimate the diagnostic value in screening. A meta-analysis was performed to obtain the value of CT-colonography for screening. A search was performed using PubMed, Embase and Cochrane. Article selection and critical appraisal was done by two reviewers. Inclusion criteria: prospective, randomized trials or cohort studies comparing CT-colonography with colonoscopy (≥50 participants), ≥95% average risk participants ≥50 years. Study characteristics and 2 x 2 contingency Tables were recorded. Sensitivity and specificity estimates were calculated per patient and per polyp (≥6 mm, ≥10 mm), using univariate and bivariate analyses. Five of 1,021 studies identified were included, including 4,086 participants ( 2 -values showed substantial heterogeneity, especially for 6-9 mm polyps and adenomas: 68.1% vs. 78.6% (sensitivity per patient). Estimated sensitivities for patients with polyps or adenomas ≥ 6 mm were 75.9% and 82.9%, corresponding specificities 94.6% and 91.4%. Estimated sensitivities for patients with polyps or adenomas ≥ 10 mm were 83.3% and 87.9%, corresponding specificities 98.7% and 97.6%. Estimated sensitivities per polyp for advanced adenomas ≥ 6 mm and ≥ 10 mm were 83.9% and 83.8%. Compared to colonoscopy, CT-colonography has a high sensitivity for adenomas ≥ 10 mm. For (advanced) adenomas ≥ 6 mm sensitivity is somewhat lower. (orig.)

  3. CT colonography without cathartic preparation: positive predictive value and patient experience in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Zueco Zueco, Carmen; Sobrido Sampedro, Carolina; Corroto, Juan D.; Rodriguez Fernandez, Paula; Fontanillo Fontanillo, Manuela [Complexo Hospitalario Universitario de Vigo - CHUVI, Vigo, Pontevedra (Spain)

    2012-06-15

    To determine the positive predictive value (PPV) for polyps {>=}6 mm detected at CT colonography (CTC) performed without cathartic preparation, with low-dose iodine faecal tagging regimen and to evaluate patient experience. 1920 average-risk patients underwent CTC without cathartic preparation. Faecal tagging was performed by diatrizoate meglumine and diatrizoate sodium at a total dose of 60 ml (22.2 g of iodine).The standard interpretation method was primary 3D with 2D problem solving. We calculated per-patient and per-polyp PPV in relation to size and morphology. All colonic segments were evaluated for image quality (faecal tagging, amount of liquid and solid residual faeces and luminal distension). Patients completed a questionnaire before and after CTC to assess preparation and examination experience. Per-polyp PPV for detected lesions of {>=}6 mm, 6-9 mm, {>=}10 mm and {>=}30 mm were 94.3%, 93.1%, 94.7% and 98%, respectively. Per-polyp PPV, according to lesion morphology, was 94.6%, 97.3% and 85.1% for sessile, pedunculated and flat polyps, respectively. Per-patient PPV was 92.8%. Preparation without frank cathartics was reported to cause minimal discomfort by 78.9% of patients. CTC without cathartic preparation and low-dose iodine faecal tagging may yield high PPVs for lesions {>=}6 mm and is well accepted by patients. circle Computed tomographic colonography (CTC) without cathartic preparation is well accepted by patients circle Cathartic-free faecal tagging CTC yields high positive predictive values circle CTC without cathartic preparation could improve uptake of colorectal cancer screening. (orig.)

  4. Burden of waiting for surveillance CT colonography in patients with screen-detected 6-9 mm polyps

    Energy Technology Data Exchange (ETDEWEB)

    Tutein Nolthenius, Charlotte J. [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Boellaard, Thierry N.; Nio, C.Y.; Bipat, Shandra; Stoker, Jaap [University of Amsterdam, Department of Radiology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Haan, Margriet C. de [Meander Medical Center, Department of Radiology, Amersfoort (Netherlands); Thomeer, Maarten G.J. [Erasmus University Medical Center, Department of Radiology, Rotterdam (Netherlands); Montauban van Swijndregt, Alexander D. [Onze Lieve Vrouwe Gasthuis, Department of Radiology, Amsterdam (Netherlands); Essink-Bot, Marie-Louise [University of Amsterdam, Public Health, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands); Kuipers, Ernst J. [Erasmus University Medical Center, Gastroenterology and Hepatology, Rotterdam (Netherlands); Erasmus University Medical Center, Internal medicine, Rotterdam (Netherlands); Dekker, Evelien [University of Amsterdam, Gastroenterology and Hepatology, Academic Medical Center, PO Box 22700, Amsterdam (Netherlands)

    2016-11-15

    We assessed the burden of waiting for surveillance CT colonography (CTC) performed in patients having 6-9 mm colorectal polyps on primary screening CTC. Additionally, we compared the burden of primary and surveillance CTC. In an invitational population-based CTC screening trial, 101 persons were diagnosed with <3 polyps 6-9 mm, for which surveillance CTC after 3 years was advised. Validated questionnaires regarding expected and perceived burden (5-point Likert scales) were completed before and after index and surveillance CTC, also including items on burden of waiting for surveillance CTC. McNemar's test was used for comparison after dichotomization. Seventy-eight (77 %) of 101 invitees underwent surveillance CTC, of which 66 (85 %) completed the expected and 62 (79 %) the perceived burden questionnaire. The majority of participants (73 %) reported the experience of waiting for surveillance CTC as 'never' or 'only sometimes' burdensome. There was almost no difference in expected and perceived burden between surveillance and index CTC. Waiting for the results after the procedure was significantly more burdensome for surveillance CTC than for index CTC (23 vs. 8 %; p = 0.012). Waiting for surveillance CTC after primary CTC screening caused little or no burden for surveillance participants. In general, the burden of surveillance and index CTC were comparable. (orig.)

  5. Evaluation of different 16-row CT colonography protocols using a porcine model; Evaluation unterschiedlicher 16-Zeilen-CT-Colonographie-Protokolle am Schweinedarmmodell

    Energy Technology Data Exchange (ETDEWEB)

    Luz, O.; Schaefer, J.; Dammann, F.; Heuschmid, M.; Claussen, C.D. [Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik; Vonthein, R. [Universitaet Tuebingen (Germany). Institut fuer Biometrie

    2004-10-01

    Purpose: To develop and to test an easily produced biological colon model with simulated polypoid lesions. Application of this phantom for the selection of an optimized scan protocol of 16-row CT colonography (CTC) for clinical use. Methods and Material: Six polypoid lesions (1-6 mm) were simulated with sutures on the inner face of a porcine colon segment (20 cm). After distending the colon segment with air, the phantom was placed in a water quench and CT scans were performed on a MDCT-scanner (Somatom Sensation 16, Siemens, Forchheim). At constant values for collimation (16 x 0.75 mm) and voltage (120 kV), 54 different combinations of mAs values (50, 75 and 100 mAs), pitch factors (1, 1.25 and 1.5) and slice thicknesses (0.75, 1.0, 1.5, 2.0, 3.0 and 5.0 mm) were tested systematically. The phantom was scanned in the longitudinal and transverse axis to simulate the different orientation of the colon in the abdomen. Axial slice images and virtual endoscopic views of all data sets were presented separately to 2 radiologists who independently determined number and size of detectable polyps. Dose exposure was measured with an Alderson phantom. Results: The colon model offered a realistic imitation of a polyp-covered, human colon. The experimental set-up allowed a systematic evaluation of polyp detection related to lesion size, orientation of the colon and CTC parameters, with other influencing factors mostly excluded. Polyps were significantly better detected in the longitudinal than in the transverse orientation of the colon. For the detection of lesions of at least 3 mm, a low dose (50 mAs) 16-row CTC should be combined with a pitch of 1.5 and a maximum slice thickness of 3 mm. For the depiction of polyps smaller than 3 mm, slice thickness and pitch should amount to 1 mm and 1.0, respectively. Effective dose of this low dose protocol is 4.08 mSv. (orig.)

  6. Feasibility of Using the Marginal Blood Vessels as Reference Landmarks for CT Colonography

    Science.gov (United States)

    Wei, Zhuoshi; Yao, Jianhua; Wang, Shijun; Liu, Jiamin; Dwyer, Andrew J.; Pickhardt, Perry J.; Nowinski, Wieslaw L.; Summers, Ronald M.

    2015-01-01

    OBJECTIVE The purpose of this study was to show the spatial relationship of the colonic marginal blood vessels and the teniae coli on CT colonography (CTC) and the use of the marginal blood vessels for supine-prone registration of polyps and for determination of proper connectivity of collapsed colonic segments. MATERIALS AND METHODS We manually labeled the marginal blood vessels on 15 CTC examinations. Colon segmentation, centerline extraction, teniae detection, and teniae identification were automatically performed. For assessment of their spatial relationships, the distances from the marginal blood vessels to the three teniae coli and to the colon were measured. Student t tests (paired, two-tailed) were performed to evaluate the differences among these distances. To evaluate the reliability of the marginal vessels as reference points for polyp correlation, we analyzed 20 polyps from 20 additional patients who underwent supine and prone CTC. The average difference of the circumferential polyp position on the supine and prone scans was computed. Student t tests (paired, two-tailed) were performed to evaluate the supine-prone differences of the distance. We performed a study on 10 CTC studies from 10 patients with collapsed colonic segments by manually tracing the marginal blood vessels near the collapsed regions to resolve the ambiguity of the colon path. RESULTS The average distances (± SD) from the marginal blood vessels to the tenia mesocolica, tenia omentalis, and tenia libera were 20.1 ± 3.1 mm (95% CI, 18.5–21.6 mm), 39.5 ± 4.8 mm (37.1–42.0 mm), and 36.9 ± 4.2 mm (34.8–39.1 mm), respectively. Pairwise comparison showed that these distances to the tenia libera and tenia omentalis were significantly different from the distance to the tenia mesocolica (p marginal blood vessels to the colon wall was 15.3 ± 2.0 mm (14.2–16.3 mm). For polyp localization, the average difference of the circumferential polyp position on the supine and prone scans was 9

  7. CT colonography: computer-aided detection of morphologically flat T1 colonic carcinoma

    International Nuclear Information System (INIS)

    Taylor, Stuart A.; Iinuma, Gen; Saito, Yutaka; Zhang, Jie; Halligan, Steve

    2008-01-01

    The purpose was to evaluate the ability of computer-aided detection (CAD) software to detect morphologically flat early colonic carcinoma using CT colonography (CTC). Twenty-four stage T1 colonic carcinomas endoscopically classified as flat (width over twice height) were accrued from patients undergoing staging CTC. Tumor location was annotated by three experienced radiologists in consensus aided by the endosocpic report. CAD software was then applied at three settings of sphericity (0, 0.75, and 1). Computer prompts were categorized as either true positive (overlapping tumour boundary) or false positive. True positives were subclassified as focal or non focal. The 24 cancers were endoscopically classified as type IIa (n=11) and type IIa+IIc (n=13). Mean size (range) was 27 mm (7-70 mm). CAD detected 20 (83.3%), 17 (70.8%), and 13 (54.1%) of the 24 cancers at filter settings of 0, 0.75, and 1, respectively with 3, 4, and 8 missed cancers of type IIa, respectively. The mean total number of false-positive CAD marks per patient at each filter setting was 36.5, 21.1, and 9.5, respectively, excluding polyps. At all settings, >96.1% of CAD true positives were classified as focal. CAD may be effective for the detection of morphologically flat cancer, although minimally raised laterally spreading tumors remain problematic. (orig.)

  8. Five year colorectal cancer outcomes in a large negative CT colonography screening cohort

    Energy Technology Data Exchange (ETDEWEB)

    Kim, David H.; Pooler, B.D.; Pickhardt, Perry J. [University of Wisconsin School of Medicine and Public Health, Department of Radiology, Madison, WI (United States); Weiss, Jennifer M. [University of Wisconsin School of Medicine and Public Health, Section of Gastroenterology, Department of Internal Medicine, Madison, WI (United States)

    2012-07-15

    To assess the 5-year incidence of clinically presenting colorectal cancers following a negative CT colonography (CTC) screening examination, as few patient outcome data regarding a negative CTC screening result exist. Negative CTC screening patients (n = 1,050) in the University of Wisconsin Health system over a 14-month period were included. An electronic medical record (EMR) review was undertaken, encompassing provider, colonoscopy, imaging and histopathology reports. Incident colorectal cancers and other important GI tumours were recorded. Of the 1,050 cohort (mean [{+-}SD] age 56.9 {+-} 7.4 years), 39 (3.7%) patients were excluded owing to lack of follow-up within our system beyond the initial screening CTC. The remaining 1,011 patients were followed for an average of 4.73 {+-} 1.15 years. One incident colorectal adenocarcinoma represented a crude cancer incidence of 0.2 cancers per 1,000 patient years. EMR revealed 14 additional patients with clinically important GI tumours including: advanced adenomas (n = 11), appendiceal goblet cell carcinoid (n = 1), appendiceal mucinous adenoma (n = 1) and metastatic ileocolonic carcinoid (n = 1). All positive patients including the incident carcinoma are alive at the time of review. Clinically presenting colorectal adenocarcinoma is rare in the 5 years following negative screening CTC, suggesting that current strategies, including non-reporting of diminutive lesions, are appropriate. (orig.)

  9. Five year colorectal cancer outcomes in a large negative CT colonography screening cohort

    International Nuclear Information System (INIS)

    Kim, David H.; Pooler, B.D.; Pickhardt, Perry J.; Weiss, Jennifer M.

    2012-01-01

    To assess the 5-year incidence of clinically presenting colorectal cancers following a negative CT colonography (CTC) screening examination, as few patient outcome data regarding a negative CTC screening result exist. Negative CTC screening patients (n = 1,050) in the University of Wisconsin Health system over a 14-month period were included. An electronic medical record (EMR) review was undertaken, encompassing provider, colonoscopy, imaging and histopathology reports. Incident colorectal cancers and other important GI tumours were recorded. Of the 1,050 cohort (mean [±SD] age 56.9 ± 7.4 years), 39 (3.7%) patients were excluded owing to lack of follow-up within our system beyond the initial screening CTC. The remaining 1,011 patients were followed for an average of 4.73 ± 1.15 years. One incident colorectal adenocarcinoma represented a crude cancer incidence of 0.2 cancers per 1,000 patient years. EMR revealed 14 additional patients with clinically important GI tumours including: advanced adenomas (n = 11), appendiceal goblet cell carcinoid (n = 1), appendiceal mucinous adenoma (n = 1) and metastatic ileocolonic carcinoid (n = 1). All positive patients including the incident carcinoma are alive at the time of review. Clinically presenting colorectal adenocarcinoma is rare in the 5 years following negative screening CTC, suggesting that current strategies, including non-reporting of diminutive lesions, are appropriate. (orig.)

  10. Prevalence and distribution of colonic diverticula assessed with CT colonography (CTC)

    Energy Technology Data Exchange (ETDEWEB)

    De Cecco, Carlo Nicola [University of Rome ' ' Sapienza' ' - Polo Pontino, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Medical University of South Carolina, Department of Radiology and Radiological Sciences, Charleston, SC (United States); Ciolina, Maria; Rengo, Marco; Bellini, Davide; Muscogiuri, Giuseppe; Iafrate, Franco; Laghi, Andrea [University of Rome ' ' Sapienza' ' - Polo Pontino, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Annibale, Bruno [University of Rome ' ' Sapienza' ' - Sant' Andrea Hospital, Department of Digestive and Liver Disease, Rome (Italy); Maruotti, Antonello [University ' ' Roma Tre' ' , Department of Public Institutions, Economy and Society, Rome (Italy); University of Southampton, Southampton Statistical Sciences Research Institute and School of Mathematics, Southampton (United Kingdom); Saba, Luca [Azienda Ospedaliera Universitaria di Cagliari, Department of Radiology, Cagliari (Italy)

    2016-03-15

    This study aimed to evaluate the prevalence of colonic diverticula according to age, gender, distribution, disease extension and symptoms with CT colonography (CTC). The study population included 1091 consecutive patients who underwent CTC. Patients with diverticula were retrospectively stratified according to age, gender, clinical symptoms and colonic segment involvement. Extension of colonic diverticula was evaluated using a three-point quantitative scale. Using this data, a multivariate regression analysis was applied to investigate the existence of any correlation among variables. Colonic diverticula were observed in 561 patients (240 men, mean age 68 ± 12 years). Symptomatic uncomplicated diverticular disease (SUDD) was present in 47.4 % of cases. In 25.6 % of patients ≤40 years, at least one diverticulum in the colon was observed. Prevalence of right-sided diverticula in patients >60 years was 14.2 % in caecum and 18.5 % in ascending colon. No significant difference was found between symptomatic and asymptomatic patients regarding diverticula prevalence and extension. No correlation was present between diverticula extension and symptoms. The incidence of colonic diverticula appears to be greater than expected. Right colon diverticula do not appear to be an uncommon finding, with their prevalence increasing with patient age. SUDD does not seem to be related to diverticula distribution and extension. (orig.)

  11. Prevalence and distribution of colonic diverticula assessed with CT colonography (CTC)

    International Nuclear Information System (INIS)

    De Cecco, Carlo Nicola; Ciolina, Maria; Rengo, Marco; Bellini, Davide; Muscogiuri, Giuseppe; Iafrate, Franco; Laghi, Andrea; Annibale, Bruno; Maruotti, Antonello; Saba, Luca

    2016-01-01

    This study aimed to evaluate the prevalence of colonic diverticula according to age, gender, distribution, disease extension and symptoms with CT colonography (CTC). The study population included 1091 consecutive patients who underwent CTC. Patients with diverticula were retrospectively stratified according to age, gender, clinical symptoms and colonic segment involvement. Extension of colonic diverticula was evaluated using a three-point quantitative scale. Using this data, a multivariate regression analysis was applied to investigate the existence of any correlation among variables. Colonic diverticula were observed in 561 patients (240 men, mean age 68 ± 12 years). Symptomatic uncomplicated diverticular disease (SUDD) was present in 47.4 % of cases. In 25.6 % of patients ≤40 years, at least one diverticulum in the colon was observed. Prevalence of right-sided diverticula in patients >60 years was 14.2 % in caecum and 18.5 % in ascending colon. No significant difference was found between symptomatic and asymptomatic patients regarding diverticula prevalence and extension. No correlation was present between diverticula extension and symptoms. The incidence of colonic diverticula appears to be greater than expected. Right colon diverticula do not appear to be an uncommon finding, with their prevalence increasing with patient age. SUDD does not seem to be related to diverticula distribution and extension. (orig.)

  12. Low-dose CT colonography in children: initial experience, technical feasibility and utility

    International Nuclear Information System (INIS)

    Anupindi, Sudha; Perumpillichira, James; Zalis, Michael E.; Jaramillo, Diego; Israel, Esther J.

    2005-01-01

    CT colonography (CTC) is utilized as a diagnostic tool in the detection of colon polyps and early colorectal cancer in adults. Large studies in the literature, although focused on adult populations, have shown CTC to be a safe, accurate, non-invasive technique. We evaluated the technical feasibility of CTC in children using a low-dose technique. From November 2001 to April 2004 we evaluated eight patients (3-17 years) with non-contrast CTC. Seven of the patients had CTC, followed by standard colonoscopy (SC) the same day; in one patient, CTC followed a failed SC. CTC results were compared to results of SC. The estimated effective dose from each CTC was calculated and compared to that of standard barium enema. CTC results were consistent with those of SC. Sensitivity for polyps 5-10 mm was 100%, and sensitivity for polyps 10 mm and larger was 66.7%. The estimated mean effective dose was 2.17 mSv for CTC, compared to the 5-6 mSv for a standard air-contrast barium enema in a small child. Our initial experience shows CTC in children is well-tolerated, safe, and useful. The procedure can be performed successfully with a low radiation dose, and preliminary results compare well with SC. (orig.)

  13. Cost analysis of colorectal cancer screening with CT colonography in Italy.

    Science.gov (United States)

    Mantellini, Paola; Lippi, Giuseppe; Sali, Lapo; Grazzini, Grazia; Delsanto, Silvia; Mallardi, Beatrice; Falchini, Massimo; Castiglione, Guido; Carozzi, Francesca Maria; Mascalchi, Mario; Milani, Stefano; Ventura, Leonardo; Zappa, Marco

    2018-06-01

    Unit costs of screening CT colonography (CTC) can be useful for cost-effectiveness analyses and for health care decision-making. We evaluated the unit costs of CTC as a primary screening test for colorectal cancer in the setting of a randomized trial in Italy. Data were collected within the randomized SAVE trial. Subjects were invited to screening CTC by mail and requested to have a pre-examination consultation. CTCs were performed with 64- and 128-slice CT scanners after reduced or full bowel preparation. Activity-based costing was used to determine unit costs per-process, per-participant to screening CTC, and per-subject with advanced neoplasia. Among 5242 subjects invited to undergo screening CTC, 1312 had pre-examination consultation and 1286 ultimately underwent CTC. Among 129 subjects with a positive CTC, 126 underwent assessment colonoscopy and 67 were ultimately diagnosed with advanced neoplasia (i.e., cancer or advanced adenoma). Cost per-participant of the entire screening CTC pathway was €196.80. Average cost per-participant for the screening invitation process was €17.04 and €9.45 for the pre-examination consultation process. Average cost per-participant of the CTC execution and reading process was €146.08 and of the diagnostic assessment colonoscopy process was €24.23. Average cost per-subject with advanced neoplasia was €3777.30. Cost of screening CTC was €196.80 per-participant. Our data suggest that the more relevant cost of screening CTC, amenable of intervention, is related to CTC execution and reading process.

  14. Design of a multicentre randomized trial to evaluate CT colonography versus colonoscopy or barium enema for diagnosis of colonic cancer in older symptomatic patients: The SIGGAR study

    Directory of Open Access Journals (Sweden)

    Edwards Rob

    2007-10-01

    Full Text Available Abstract Background and Aims The standard whole-colon tests used to investigate patients with symptoms of colorectal cancer are barium enema and colonoscopy. Colonoscopy is the reference test but is technically difficult, resource intensive, and associated with adverse events, especially in the elderly. Barium enema is safer but has reduced sensitivity for cancer. CT colonography ("virtual colonoscopy" is a newer alternative that may combine high sensitivity for cancer with safety and patient acceptability. The SIGGAR trial aims to determine the diagnostic efficacy, acceptability, and economic costs associated with this new technology. Methods The SIGGAR trial is a multi-centre randomised comparison of CT colonography versus standard investigation (barium enema or colonoscopy, the latter determined by individual clinician preference. Diagnostic efficacy for colorectal cancer and colonic polyps measuring 1 cm or larger will be determined, as will the physical and psychological morbidity associated with each diagnostic test, the latter via questionnaires developed from qualitative interviews. The economic costs of making or excluding a diagnosis will be determined for each diagnostic test and information from the trial and other data from the literature will be used to populate models framed to summarise the health effects and costs of alternative approaches to detection of significant colonic neoplasia in patients of different ages, prior risks and preferences. This analysis will focus particularly on the frequency, clinical relevance, costs, and psychological and physical morbidity associated with detection of extracolonic lesions by CT colonography. Results Recruitment commenced in March 2004 and at the time of writing (July 2007 5025 patients have been randomised. A lower than expected prevalence of end-points in the barium enema sub-trial has caused an increase in sample size. In addition to the study protocol, we describe our approach to

  15. Comparative evaluation of the fecal-tagging quality in CT colonography: barium vs. iodinated oral contrast agent.

    Science.gov (United States)

    Nagata, Koichi; Singh, Anand Kumar; Sangwaiya, Minal Jagtiani; Näppi, Janne; Zalis, Michael E; Cai, Wenli; Yoshida, Hiroyuki

    2009-11-01

    The purpose of this evaluation was to compare the tagging quality of a barium-based regimen with that of iodine-based regimens for computed tomographic (CT) colonography. Tagging quality was assessed retrospectively in three different types of fecal-tagging CT colonographic cases: 24 barium-based cases, 22 nonionic iodine-based cases, and 24 ionic iodine-based cases. For the purpose of evaluation, the large intestine was divided into six segments, and the tagging homogeneity of a total of 420 segments (70 patients) was graded by three blinded readers from 0 (heterogeneous) to 4 (homogeneous). For barium-based cases, the average score for the three readers was 2.4, whereas it was 3.4 for nonionic iodine and 3.6 for ionic iodine. The percentages of segments that were assigned scores of 4 (excellent tagging [100%]) were 11.6%, 61.9%, and 72.9% for the barium-based, nonionic iodine-based, and ionic iodine-based regimens, respectively. The homogeneity scores of iodine-based fecal-tagging regimens were significantly higher than those of the barium-based fecal-tagging regimen (P barium-based regimen (P barium-based fecal-tagging regimen. Iodine-based fecal-tagging regimens can provide an appropriate method for use in nonlaxative or minimum-laxative CT colonography.

  16. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions

    International Nuclear Information System (INIS)

    Xu, Yonghua; Cai, Wenli; Nappi, Janne; Yoshida, Hiro

    2012-01-01

    Purpose: To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (2D). Materials and methods: Forty CTC cases with flat lesions were retrospectively observed. The Subjects from a multicenter clinical trial underwent cathartic bowel preparation with orally administrated barium-based fecal-tagging. Sixty-nine flat lesions were confirmed using colonoscopy and histopathology as a reference standard. The results from SAEC reading were compared with those of prospective V3D and 2D readings. Results: Overall detection sensitivity with SAEC was 52% (36/69), which was statistically higher than that of 32% (22/69) and 29% (20/69) with V3D and 2D readings, respectively (p < 0.05). The sensitivities in detecting not-on-fold flat lesions were 63% (24/38), 45% (17/38), and 42% (16/38) with SAEC, V3D, and 2D readings, respectively; whereas those of on-fold flat lesions were 39% (12/31), 16% (5/31), and 13% (4/31), respectively. None of the eight flat lesions (2-9 mm) at cecum was detected by any of the three reading methods. Excluding the flat lesions at cecum, the sensitivity with SAEC for detecting flat lesion ≥4 mm increased to 84% (31/37). Conclusions: The fecal-tagging CTC with structure-analysis electronic cleansing could yield a high sensitivity for detecting flat lesions ≥4 mm. The not-on-fold flat lesions were detected with higher sensitivity than on-fold flat lesions.

  17. A robust and efficient approach to detect 3D rectal tubes from CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Yang Xiaoyun; Slabaugh, Greg [Medicsight PLC, Kensington Centre, 66 Hammersmith Road, London (United Kingdom)

    2011-11-15

    Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

  18. A robust and efficient approach to detect 3D rectal tubes from CT colonography

    International Nuclear Information System (INIS)

    Yang Xiaoyun; Slabaugh, Greg

    2011-01-01

    Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

  19. Computer-aided diagnosis in contrast-enhanced CT colonography: an approach based on contrast

    International Nuclear Information System (INIS)

    Luboldt, Wolfgang; Kroll, Manuela; Vogl, Thomas J.; Mann, Carolin; Vonthein, Reinhard; Stueker, Dietmar; Luz, Oliver; Claussen, Claus D.; Tryon, Cathy L.

    2002-01-01

    Automation in colorectal mass detection is achieved as soon as the voxels representing colorectal masses can be automatically segmented. We tested the Hounsfield (HU) value in intensely contrast enhanced high-resolution CT colonography for automated segmentation of colorectal masses in 18 patients with 35 polyps (28<10 mm, 7 ≥10 mm) and 7 carcinomas. Mean HU values of the colonic wall and masses were determined to deduce a gradient threshold for a segmentation process, which encodes the voxels bordering the colonic lumen with a colour ranging in intensity from 0 to 100% according to the selected gradient threshold range in the volume rendering. The results of the automated segmentation process were superimposed on a virtual double contrast and endoscopic display and validated through correlation with morphology. Mean HU values and their standard deviations for the colonic wall, polyps <10 mm, polyps ≥10 mm and carcinomas were 63±24, 154±38, 116±41 and 108±29 HU, respectively. A gradient threshold ranging from 90 to 160 HU resulted in colour pools in 6 of 7 of polyps ≥10 mm, and 6 of 7 carcinomas that were significant enough to prospectively guide the reader's attention to these masses. Due to the superposition of ''false-positive'' voxels in the projection view, the virtual endoscopic perspective was superior to the virtual double contrast display for controlling the segmentation results. The HU value is promising for automated segmentation of colorectal masses but needs to be combined with morphological parameters to render automated colorectal mass detection more accurate. Further refinements of the method with subsequent analysis of its accuracy, as well as analogue studies with contrast-enhanced MRI, appear warranted. More information at http://www.multiorganscreening.org (orig.)

  20. Computer-assisted polyp matching between optical colonoscopy and CT colonography: a phantom study

    Science.gov (United States)

    Roth, Holger R.; Hampshire, Thomas E.; Helbren, Emma; Hu, Mingxing; Vega, Roser; Halligan, Steve; Hawkes, David J.

    2014-03-01

    Potentially precancerous polyps detected with CT colonography (CTC) need to be removed subsequently, using an optical colonoscope (OC). Due to large colonic deformations induced by the colonoscope, even very experienced colonoscopists find it difficult to pinpoint the exact location of the colonoscope tip in relation to polyps reported on CTC. This can cause unduly prolonged OC examinations that are stressful for the patient, colonoscopist and supporting staff. We developed a method, based on monocular 3D reconstruction from OC images, that automatically matches polyps observed in OC with polyps reported on prior CTC. A matching cost is computed, using rigid point-based registration between surface point clouds extracted from both modalities. A 3D printed and painted phantom of a 25 cm long transverse colon segment was used to validate the method on two medium sized polyps. Results indicate that the matching cost is smaller at the correct corresponding polyp between OC and CTC: the value is 3.9 times higher at the incorrect polyp, comparing the correct match between polyps to the incorrect match. Furthermore, we evaluate the matching of the reconstructed polyp from OC with other colonic endoluminal surface structures such as haustral folds and show that there is a minimum at the correct polyp from CTC. Automated matching between polyps observed at OC and prior CTC would facilitate the biopsy or removal of true-positive pathology or exclusion of false-positive CTC findings, and would reduce colonoscopy false-negative (missed) polyps. Ultimately, such a method might reduce healthcare costs, patient inconvenience and discomfort.

  1. Deep learning of contrast-coated serrated polyps for computer-aided detection in CT colonography

    Science.gov (United States)

    Näppi, Janne J.; Pickhardt, Perry; Kim, David H.; Hironaka, Toru; Yoshida, Hiroyuki

    2017-03-01

    Serrated polyps were previously believed to be benign lesions with no cancer potential. However, recent studies have revealed a novel molecular pathway where also serrated polyps can develop into colorectal cancer. CT colonography (CTC) can detect serrated polyps using the radiomic biomarker of contrast coating, but this requires expertise from the reader and current computer-aided detection (CADe) systems have not been designed to detect the contrast coating. The purpose of this study was to develop a novel CADe method that makes use of deep learning to detect serrated polyps based on their contrast-coating biomarker in CTC. In the method, volumetric shape-based features are used to detect polyp sites over soft-tissue and fecal-tagging surfaces of the colon. The detected sites are imaged using multi-angular 2D image patches. A deep convolutional neural network (DCNN) is used to review the image patches for the presence of polyps. The DCNN-based polyp-likelihood estimates are merged into an aggregate likelihood index where highest values indicate the presence of a polyp. For pilot evaluation, the proposed DCNN-CADe method was evaluated with a 10-fold cross-validation scheme using 101 colonoscopy-confirmed cases with 144 biopsy-confirmed serrated polyps from a CTC screening program, where the patients had been prepared for CTC with saline laxative and fecal tagging by barium and iodine-based diatrizoate. The average per-polyp sensitivity for serrated polyps >=6 mm in size was 93+/-7% at 0:8+/-1:8 false positives per patient on average. The detection accuracy was substantially higher that of a conventional CADe system. Our results indicate that serrated polyps can be detected automatically at high accuracy in CTC.

  2. Bowel preparation in CT colonography. Is diet restriction necessary? A randomised trial (DIETSAN)

    Energy Technology Data Exchange (ETDEWEB)

    Bellini, Davide; De Santis, Domenico; Caruso, Damiano; Rengo, Marco; Biondi, Tommaso; Laghi, Andrea [Rome Univ. ' ' Sapienza' ' (Italy). Dept. of Radiological Sciences, Oncology and Pathology; I.C.O.T. Hospital, Latina (Italy); Ferrari, Riccardo [San Camillo Forlanini Hospital, Rome (Italy). Dept. of Emergency Radiology

    2018-01-15

    To investigate whether diet restriction affects quality of colon cleansing and patient tolerance during reduced bowel preparation for CT colonography (CTC). Asymptomatic and symptomatic patients were enrolled in this pragmatic, single-centre, randomised trial. All patients were randomly assigned (1:1 ratio, blocks of ten) to receive a reduced bowel preparation and faecal tagging with (Diet-Restriction-Group [DR]) or without (No-Diet-Restriction-Group [NDR]) dietary restriction. Five readers performed a blinded subjective image analysis, by means of 4-point Likert-scales from 0 (highest score) to 3 (worst score). Endpoints were the quality of large bowel cleansing and tolerance to the assigned bowel preparation regimen. The trial is registered at ClinicalTrial.gov (URomLSDBAL1). Ninety-five patients were randomly allocated to treatments (48 in NDR-group, 47 in DR-group). Both groups resulted in optimal colon cleansing. The mean residual stool (0.22, 95%CI 0.00-0.44) and fluid burden (0.39, 95%CI 0.25-0.53) scores for patients in DR-group were similar to those in patients in NDR-group (0.25, 95%CI 0.03-0.47 [p = 0.82] and 0.49, 95%CI 0.30-0.67 [p = 0.38], respectively). Tolerance was significantly better in NDR-group. A reduced bowel preparation in association with faecal tagging and without any dietary restriction demonstrated optimal colon cleansing effectiveness for CTC, providing better patient compliance compared with dietary restriction. (orig.)

  3. Bowel preparation in CT colonography. Is diet restriction necessary? A randomised trial (DIETSAN)

    International Nuclear Information System (INIS)

    Bellini, Davide; De Santis, Domenico; Caruso, Damiano; Rengo, Marco; Biondi, Tommaso; Laghi, Andrea; Ferrari, Riccardo

    2018-01-01

    To investigate whether diet restriction affects quality of colon cleansing and patient tolerance during reduced bowel preparation for CT colonography (CTC). Asymptomatic and symptomatic patients were enrolled in this pragmatic, single-centre, randomised trial. All patients were randomly assigned (1:1 ratio, blocks of ten) to receive a reduced bowel preparation and faecal tagging with (Diet-Restriction-Group [DR]) or without (No-Diet-Restriction-Group [NDR]) dietary restriction. Five readers performed a blinded subjective image analysis, by means of 4-point Likert-scales from 0 (highest score) to 3 (worst score). Endpoints were the quality of large bowel cleansing and tolerance to the assigned bowel preparation regimen. The trial is registered at ClinicalTrial.gov (URomLSDBAL1). Ninety-five patients were randomly allocated to treatments (48 in NDR-group, 47 in DR-group). Both groups resulted in optimal colon cleansing. The mean residual stool (0.22, 95%CI 0.00-0.44) and fluid burden (0.39, 95%CI 0.25-0.53) scores for patients in DR-group were similar to those in patients in NDR-group (0.25, 95%CI 0.03-0.47 [p = 0.82] and 0.49, 95%CI 0.30-0.67 [p = 0.38], respectively). Tolerance was significantly better in NDR-group. A reduced bowel preparation in association with faecal tagging and without any dietary restriction demonstrated optimal colon cleansing effectiveness for CTC, providing better patient compliance compared with dietary restriction. (orig.)

  4. Max-AUC feature selection in computer-aided detection of polyps in CT colonography.

    Science.gov (United States)

    Xu, Jian-Wu; Suzuki, Kenji

    2014-03-01

    We propose a feature selection method based on a sequential forward floating selection (SFFS) procedure to improve the performance of a classifier in computerized detection of polyps in CT colonography (CTC). The feature selection method is coupled with a nonlinear support vector machine (SVM) classifier. Unlike the conventional linear method based on Wilks' lambda, the proposed method selected the most relevant features that would maximize the area under the receiver operating characteristic curve (AUC), which directly maximizes classification performance, evaluated based on AUC value, in the computer-aided detection (CADe) scheme. We presented two variants of the proposed method with different stopping criteria used in the SFFS procedure. The first variant searched all feature combinations allowed in the SFFS procedure and selected the subsets that maximize the AUC values. The second variant performed a statistical test at each step during the SFFS procedure, and it was terminated if the increase in the AUC value was not statistically significant. The advantage of the second variant is its lower computational cost. To test the performance of the proposed method, we compared it against the popular stepwise feature selection method based on Wilks' lambda for a colonic-polyp database (25 polyps and 2624 nonpolyps). We extracted 75 morphologic, gray-level-based, and texture features from the segmented lesion candidate regions. The two variants of the proposed feature selection method chose 29 and 7 features, respectively. Two SVM classifiers trained with these selected features yielded a 96% by-polyp sensitivity at false-positive (FP) rates of 4.1 and 6.5 per patient, respectively. Experiments showed a significant improvement in the performance of the classifier with the proposed feature selection method over that with the popular stepwise feature selection based on Wilks' lambda that yielded 18.0 FPs per patient at the same sensitivity level.

  5. Trends in CT colonography: bibliometric analysis of the 100 most-cited articles.

    Science.gov (United States)

    Mohammed, Mohammed Fahim; Chahal, Tejbir; Gong, Bo; Bhulani, Nizar; O'Keefe, Michael; O'Connell, Timothy; Nicolaou, Savvas; Khosa, Faisal

    2017-12-01

    Our purpose was to identify the top 100 cited articles, which focused on CT colonography (CTC). This list could then be analysed to establish trends in CTC research while also identifying common characteristics of highly cited works. Web of Science search was used to create a database of scientific journals using our search terms. A total of 10,597 articles were returned from this search. Articles were included if they focused on diagnostic imaging, imaging technique, cost-effectiveness analysis, clinical use, patient preference or trends in CTC. Articles were ranked by citation count and screened by two attending radiologists. The following information was collected from each article: database citations, citations per year, year published, journal, authors, department affiliation, study type and design, statistical analysis, sample size, modality and topic. Citations for the top 100 articles ranged from 73 to 1179, and citations per year ranged from 4.5 to 84.21. Articles were published across 22 journals, most commonly Radiology (n = 37) and American Journal of Roentgenology (n = 19). Authors contributed from 1 to 20 articles. 19% of first authors were affiliated with a department other than radiology. Of the 100 articles, the most common topics were imaging technique (n = 40), diagnostic utility of imaging (n = 28) and clinical uses (n = 18). Our study provides intellectual milestones in CTC research, reflecting on the characteristics and quality of published literature. This work also provides the most influential references related to CTC and serves as a guide to the features of a citable paper in this field.

  6. CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes

    International Nuclear Information System (INIS)

    Liedenbaum, Marjolein H.; Vries, A.H. de; Bipat, S.; Stoker, J.; Gouw, C.I.B.F.; Rijn, A.F. van; Dekker, E.

    2010-01-01

    The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = 0.749). Mean per-polyp sensitivity for lesions ≥10 mm was 86% in group 1 and 97% in group 2 (p = 0.355). Patient burden from diarrhoea significantly decreased for patients in group 2. One-day preparation with meglumine ioxithalamate results in an improved patient acceptability compared with 2-day preparation and has a comparable, excellent image quality and good diagnostic performance. (orig.)

  7. CT colonography for preoperative examination of the proximal colon using a transanal drainage tube for acute malignant colonic obstruction

    International Nuclear Information System (INIS)

    Sasaki, Kazuaki; Hirano, Yuji; Oono, Keisuke; Sasaki, Kazunori; Someya, Tetsufumi; Harada, Keisuke; Ezoe, Eiri; Furuhata, Tomohisa; Hirata, Koichi

    2011-01-01

    The purpose of this study was to evaluate the feasibility of CT colonography for preoperative examination of the proximal colon using a transanal drainage tube in patients with acute colon obstruction caused by colorectal cancer. Ten patients who received initial treatment for acute malignant colon obstruction at our hospital between June 2004 and December 2008 were studied. In these patients, elective surgery was possible after transanal drainage tube insertion, and the colon on the oral side from the cancer lesion was examined using a drainage tube. Air was injected through the tube into the oral side of the colon, and CT colonography was assessed for the presence or absence of lesions on the oral side. The images of the oral side of the colon were good enough to allow adequate interpretation in 9 of the 10 patients. In the first patient, the visualization of the area near the lesion was somewhat fair, although the right side colon was well visualized. There were no complications associated with this examination. The present preoperative examination using a transanal drainage tube was useful for determining the extent of intestinal resection when patients were not candidates for colonoscopy or barium enema examination. (author)

  8. Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

    International Nuclear Information System (INIS)

    Wang Shijun; Yao Jianhua; Liu Jiamin; Petrick, Nicholas; Van Uitert, Robert L.; Periaswamy, Senthil; Summers, Ronald M.

    2009-01-01

    Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27±52.97 to 14.98 mm±11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.

  9. Magnetic resonance colonography with a limited bowel preparation and automated carbon dioxide insufflation in comparison to conventional colonoscopy: Patient burden and preferences

    Energy Technology Data Exchange (ETDEWEB)

    Paardt, M.P. van der, E-mail: m.p.vanderpaardt@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Boellaard, T.N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Zijta, F.M., E-mail: fmzijta@yahoo.com [Department of Radiology, Medisch Centrum Haaglanden, Den Haag (Netherlands); Baak, L.C., E-mail: l.c.baak@olvg.nl [Department of Gastroenterology and Hepatology, Onze Lieve Vrouwe Gasthuis, Amsterdam (Netherlands); Depla, A.C.T.M., E-mail: actm.depla@slz.nl [Department of Gastroenterology and Hepatology, Slotervaartziekenhuis, Amsterdam (Netherlands); Dekker, E., E-mail: e.dekker@amc.uva.nl [Department of Gastroenterology and Hepatology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Nederveen, A.J., E-mail: a.j.nederveen@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Bipat, S., E-mail: s.bipat@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands); Stoker, J., E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Center Amsterdam, Amsterdam (Netherlands)

    2015-01-15

    Highlights: • MR colonography with a limited bowel preparation and automated carbon dioxide insufflation demonstrated less burden compared to colonoscopy. • When discarding the bowel preparation, the examinations were rated equally burdensome. • The majority of patients preferred MR colonography over colonoscopy for their future examination of the bowel. - Abstract: Objectives: To evaluate patient burden and preferences for MR colonography with a limited bowel preparation and automated carbon dioxide insufflation in comparison to conventional colonoscopy. Methods: Symptomatic patients were consecutively recruited to undergo MR colonography with automated carbon dioxide insufflation and a limited bowel preparation followed within four weeks by colonoscopy with a standard bowel cleansing preparation. Four questionnaires regarding burden (on a five-point scale) and preferences (on a seven-point scale) were addressed after MR colonography and colonoscopy and five weeks after colonoscopy. Results: Ninety-nine patients (47 men, 52 women; mean age 62.3, SD 8.7) were included. None of the patients experienced severe or extreme burden from the MR colonography bowel preparation compared to 31.5% of the patients for the colonoscopy bowel preparation. Colonoscopy was rated more burdensome (25.6% severe or extreme burden) compared to MR colonography (5.2% severe or extreme burden) (P < 0.0001). When discarding the bowel preparations, the examinations were rated equally burdensome (P = 0.35). The majority of patients (61.4%) preferred MR colonography compared to colonoscopy (29.5%) immediately after the examinations and five weeks later (57.0% versus 39.5%). Conclusion: MR colonography with a limited bowel preparation and automated carbon dioxide insufflation demonstrated less burden compared to colonoscopy. The majority of patients preferred MR colonography over colonoscopy.

  10. Computer-Aided Detection of Polyps in CT Colonography Using Logistic Regression

    NARCIS (Netherlands)

    Van Ravesteijn, V.F.; Van Wijk, C.; Vos, F.M.; Truyen, R.; Peters, J.F.; Stoker, J.; Van Vliet, L.J.

    2010-01-01

    We present a computer-aided detection (CAD) system for computed tomography colonography that orders the polyps according to clinical relevance. TheCADsystem consists of two steps: candidate detection and supervised classification. The characteristics of the detection step lead to specific choices

  11. CT Colonography: Role of a second reader CAD paradigm in the initial training of radiologists

    International Nuclear Information System (INIS)

    Neri, Emanuele; Faggioni, Lorenzo; Regge, Daniele; Vagli, Paola; Turini, Francesca; Cerri, Francesca; Picano, Eugenia; Giusti, Sabina; Bartolozzi, Carlo

    2011-01-01

    Purpose: To evaluate the influence of CAD for the evaluation of CT colonography (CTC) datasets by inexperienced readers during the attendance of a dedicated hands-on training course. Method and materials: Twenty-seven radiologists inexperienced in CTC (11 with no CTC training at all, 16 having previously reviewed no more than 10 CTC cases overall) attended a hands-on training course based on direct teaching on fifteen workstations (four Advantage Windows 4.4 with Colon VCAR software, GE; six CADCOLON, Im3D; five ColonScreen (Toshiba/Voxar) with ColonCAD TM API, Medicsight). During the course, readers were instructed to analyze 26 CTC cases including 38 colonic lesions obtained through low-dose MDCT acquisitions, consisting of 12 polyps sized less than 6 mm, 9 polyps sized between 6 and 10 mm, 12 polyps sized between 11 mm and 30 mm, and 5 colonic masses sized >3 cm. CTC images were reviewed by each reader both in 2D and 3D mode, respectively by direct evaluation of native axial images and MPR reconstructions, and virtual endoscopy or dissected views. Each reader had 15 min time for assessing each dataset without CAD, after which results were compared with those provided by CAD software. Global rater sensitivity for each lesion size before and after CAD usage was compared by means of two-tailed Student's t test, while sensitivity of each single reader before and after CAD usage was assessed with the McNemar test. Results: For lesions sized 30 mm, sensitivity before CAD-assisted reading was 0.3556 ± 0.3105 and did not change after CAD usage (p = 1). Sensitivity of each single rater did not significantly differ before and after CAD for any lesion size category (McNemar test, p > 0.05). Specificity was not significantly different before and after CAD for any lesion size (>96% for all size categories). Conclusion: CAD usage led to increased overall sensitivity of inexperienced readers for all polyps sizes, except for lesions >30 mm, but sensitivity of individual raters

  12. Colonic angiodysplasia on CT colonography: case report and characteristic imaging findings

    Directory of Open Access Journals (Sweden)

    Laura Filograna, MD

    2017-12-01

    Full Text Available Gastrointestinal angiodysplasia represents the cause of 6% of lower gastrointestinal tract bleeding, particularly in the elderly. Because of the common presentation and age range of affected patients, often patients with occult or massive gastrointestinal bleedings are investigated with colonoscopy, in the suspect of colonic cancer. Other methods are capsule enteroscopy, angiography, double-contrast barium enema, computed tomography angiography, and radionuclide scanning. In this contribution, we describe a case of colonic angiodysplasia first suspected during computed tomography colonography performed after an incomplete colonoscopy in a patient with recent anemization. The purpose is to highlight the computed tomography colonography imaging characteristics of this rare finding during such examination performed due to suspected colon carcinoma as a complementary or substitutive method of colonoscopy.

  13. Is a Double Contrast Barium Enema Necessary in Patients who Undergo a CT Colonography as a Preoperative Work-up?

    International Nuclear Information System (INIS)

    Lee, Ji Won; Lee, Soon Jin; Choi, Dong Il; Kim, Hee Jung; Chun, Ho Kyung; Yun, Seong Hyeon; Jeon, Yong Hwan; Park, Seung Bae; Kim, Min Ju

    2009-01-01

    To determine the efficiency of CT colonography (CTC), as compared with the double contrast barium enema (DCBE) for the preoperative work-up of colorectal neoplasms. A total of 39 patients underwent both a CTC and DCBE before surgery. Three abdominal radiologists and three colorectal surgeons retrospectively reviewed virtual double contrast (VDC) and DCBE images, regarding each examination for localization, conspicuity, extent and morphology of neoplasms. We reviewed the radiological reports of the CTC and DCBE for the polyps. In the case of both VDC and DCBE, 40 cancers were detected in 39 patients. According to abdominal radiologists, VDC showed the same ability to identify DCBE for localization of neoplasms (p 0.05). The performance of the CTC is comparable to the DCBE for the localization of main mass and polyps in patients with colorectal neoplasm. Barium enema don't seem to be necessary for patients who undergo a CTC as preoperative work-up

  14. CT colonography: effect of computer-aided detection of colonic polyps as a second and concurrent reader for general radiologists with moderate experience in CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Ringel, Helmut; Weber, Michael; Bogoni, Luca; Anand, Vikram X.; Hermosillo, Gerardo; Raykar, Vikas; Salganicoff, Marcos; Wolf, Matthias; Chandra, Dass; Curtin, Andrew J.; Lev-Toaff, Anna S.; Noah, Ralph; Shaw, Robert; Summerton, Susan; Tappouni, Rafel F.R.; Obuchowski, Nancy A.

    2014-01-01

    To assess the effectiveness of computer-aided detection (CAD) as a second reader or concurrent reader in helping radiologists who are moderately experienced in computed tomographic colonography (CTC) to detect colorectal polyps. Seventy CTC datasets (34 patients: 66 polyps ≥6 mm; 36 patients: no abnormalities) were retrospectively reviewed by seven radiologists with moderate CTC experience. After primary unassisted evaluation, a CAD second read and, after a time interval of ≥4 weeks, a CAD concurrent read were performed. Areas under the receiver operating characteristic (ROC) curve (AUC), along with per-segment, per-polyp and per-patient sensitivities, and also reading times, were calculated for each reader with and without CAD. Of seven readers, 86 % and 71 % achieved a higher accuracy (segment-level AUC) when using CAD as second and concurrent reader respectively. Average segment-level AUCs with second and concurrent CAD (0.853 and 0.864) were significantly greater (p < 0.0001) than average AUC in the unaided evaluation (0.781). Per-segment, per-polyp, and per-patient sensitivities for polyps ≥6 mm were significantly higher in both CAD reading paradigms compared with unaided evaluation. Second-read CAD reduced readers' average segment and patient specificity by 0.007 and 0.036 (p = 0.005 and 0.011), respectively. CAD significantly improves the sensitivities of radiologists moderately experienced in CTC for polyp detection, both as second reader and concurrent reader. (orig.)

  15. Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography

    International Nuclear Information System (INIS)

    Luboldt, W.; Kroll, M.; Wetter, A.; Vogl, T.J.; Toussaint, T.L.; Hoepffner, N.; Holzer, K.; Kluge, A.

    2004-01-01

    A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps 0 . The slope m was determined by linear regression in the correlation (lesion ∝[xA + (1 - x)V]//H) and the Y-intercept y 0 by the minimal shift of the line needed to maximize the accuracy of separating the colonic wall from the lesions. The CT value of the lesions correlated best with the intermediate phase: 0.4A+ 0.6V(r=0.8 for polyps ≥10 mm, r=0.6 for carcinomas, r=0.4 for polyps <10 mm). The accuracy in the differentiation between lesions and normal colonic wall increased with the height implemented as divisor, reached 91% and was obtained by the dynamic cut-off described by the formula: cut-off(A,V,H) = 1.1[0.4A + 0.6V]/H + 69.8. The CT value of colonic polyps or carcinomas can be increased extrinsically by scanning in the phase in which 0.4A + 0.6V reaches its maximum. Differentiating lesions from normal colon based on CT values is possible in contrast-enhanced CTC and improves when the cut-off is adjusted (normalized) to the contrast phase and lesion size. (orig.)

  16. Accuracy of Combined Computed Tomography Colonography and Dual Energy Iiodine Map Imaging for Detecting Colorectal masses using High-pitch Dual-source CT.

    Science.gov (United States)

    Sun, Kai; Han, Ruijuan; Han, Yang; Shi, Xuesen; Hu, Jiang; Lu, Bin

    2018-02-28

    To evaluate the diagnostic accuracy of combined computed tomography colonography (CTC) and dual-energy iodine map imaging for detecting colorectal masses using high-pitch dual-source CT, compared with optical colonography (OC) and histopathologic findings. Twenty-eight consecutive patients were prospectively enrolled in this study. All patients were underwent contrast-enhanced CTC acquisition using dual-energy mode and OC and pathologic examination. The size of the space-occupied mass, the CT value after contrast enhancement, and the iodine value were measured and statistically compared. The sensitivity, specificity, accuracy rate, and positive predictive and negative predictive values of dual-energy contrast-enhanced CTC were calculated and compared between conventional CTC and dual-energy iodine images. The iodine value of stool was significantly lower than the colonic neoplasia (P dual-energy iodine maps imaging was 95.6% (95% CI = 77.9%-99.2%). The specificity of the two methods was 42.8% (95% CI = 15.4%-93.5%) and 100% (95% CI = 47.9%-100%; P = 0.02), respectively. Compared with optical colonography and histopathology, combined CTC and dual-energy iodine maps imaging can distinguish stool and colonic neoplasia, distinguish between benign and malignant tumors initially and improve the diagnostic accuracy of CTC for colorectal cancer screening.

  17. Preliminary evaluation of helical CT colonography in detection of colonic diseases compared with double contrast barium enema

    International Nuclear Information System (INIS)

    Zhai Xiaoli; Zhang Lei; Zhai Renyou; Li Jie; Wang Yajie; Ding Yi

    2000-01-01

    Objective: To evaluate helical CT colonography in regard to technology principles, limitations, and clinical applications. Methods: Fifty-six patients underwent volume scanning using helical CT. The diseases included adenocarcinoma 39, adenomatous polyp 3, multiple diverticular 7, mucocele of appendix 1, and normal colon 6. All cases had been compared with double contrast barium enema (DCBE), proved by histology except the 6 normal colon and the 7 multiple diverticular. All CTC images were reconstructed using shaded surface display (SSD) on workstation. Then, perspective images such as the ones from DCBE were generated via ray sum. The images could clearly demonstrate the extent and detail of the disorder by using 'CUT' software, 'revolve' function, and zoom. Results: CTC correctly demonstrated 3-5 mm diverticulum, 3 mm ulcer, and 6 mm polyps. Not only show colon straitness clearly, CTC is also very sensitive to demonstrate the stenotic end of masses. In these cases, discovery rate of CTC is 100.0%, the rate of DCBE is 88.6%; CTC is more sensitive than DCBE in cases of tumor nodules. Ray sum can show the boundary of colonic mass extending to both proximal and distal ends, its discovery rate is 62.6%. Accuracy of localization for CTC is 100.0%. Conclusion: CTC is a novel technique for detecting colonic diseases. It is a safe, accurate, and non-invasive means for detection of lesions and is an efficient complement for DCBE. Further development in CTC technique is expected in the future

  18. Assessment of the efficacy of the education of radiographers who interpret CT-colonography examinations

    DEFF Research Database (Denmark)

    Lauridsen, Carsten Ammitzbøl; Jeppesen, Lau; Westphal, Lena

    2014-01-01

    could increase the interpretation time and create significant logistical challenges in busy diagnostic imaging departments. The shortage of radiologists makes this an impractical long‐term solution; therefore diagnostic imaging departments should ensure efficient work routines and assess...... diagnostic modalities are used for colonic evaluation including rectoscopy, flexible sigmoideoscopy, OC, fecal occult blood test, double contrast barium enema, magnetic resonance colonography and CTC. However, OC is considered to be the gold standard due to a high diagnostic accuracy and the option......‐center trial reported excellent sensitivity for large adenomas and cancers.17 A further study by Kim et al., compared the diagnostic yield from parallel OC and CTC screening programs and found similar detection rates of advanced neoplasia in the two groups.18 Some studies have documented wide inter...

  19. Vascular map combined with CT colonography for evaluating candidates for laparoscopic colorectal surgery

    International Nuclear Information System (INIS)

    Flor, Nicola; Ceretti, Andrea Pisani; Maroni, Nirvana; Opocher, Enrico; Cornalba, Gianpaolo; Campari, Alessandro; Ravelli, Anna; Lombardi, Maria Antonietta

    2015-01-01

    Contrast-enhanced computed tomography colonography (CE-CTC) is a useful guide for the laparoscopic surgeon to avoid incorrectly removing the colonic segment and the failure to diagnose of synchronous colonic and extra-colonic lesions. Lymph node dissection and vessel ligation under a laparoscopic approach can be time-consuming and can damage vessels and organs. Moreover, mesenteric vessels have extreme variations in terms of their courses and numbers. We describe the benefit of using an abdominal vascular map created by CE-CTC in laparoscopic colorectal surgery candidates. We describe patients with different diseases (colorectal cancer, diverticular disease, and inflammatory bowel disease) who underwent CE-CTC just prior to laparoscopic surgery

  20. Vascular map combined with CT colonography for evaluating candidates for laparoscopic colorectal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Flor, Nicola; Ceretti, Andrea Pisani; Maroni, Nirvana; Opocher, Enrico; Cornalba, Gianpaolo [Azienda Ospedaliera San Paolo, Milan (Italy); Campari, Alessandro; Ravelli, Anna; Lombardi, Maria Antonietta [University degli Studi di Milano, Milan (Italy)

    2015-08-15

    Contrast-enhanced computed tomography colonography (CE-CTC) is a useful guide for the laparoscopic surgeon to avoid incorrectly removing the colonic segment and the failure to diagnose of synchronous colonic and extra-colonic lesions. Lymph node dissection and vessel ligation under a laparoscopic approach can be time-consuming and can damage vessels and organs. Moreover, mesenteric vessels have extreme variations in terms of their courses and numbers. We describe the benefit of using an abdominal vascular map created by CE-CTC in laparoscopic colorectal surgery candidates. We describe patients with different diseases (colorectal cancer, diverticular disease, and inflammatory bowel disease) who underwent CE-CTC just prior to laparoscopic surgery.

  1. Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results

    International Nuclear Information System (INIS)

    Bielen, Didier; Thomeer, Maarten; Vanbeckevoort, Dirk; Marchal, Guy; Kiss, Gabriel; Maes, Frederik; Rutgeerts, Paul

    2003-01-01

    The purpose of this study was to evaluate the feasibility of a dry bowel preparation, i.e. without laxative fluids, for virtual CT colonography (VCTC), and its impact on patient acceptance compared with conventional colonoscopy (CC). A randomly chosen patient population scheduled for CC (n=11) was first submitted to VCTC after a dry preparation, consisting of low-residue meals combined with a small amount of a iodinated water-soluble contrast medium during each meal 3 days before VCTC. In different colon segments and between different persons, the degree of tagging in VCTC was evaluated and graded. Patient acceptance and future preference were assessed for both preparations as well as for both investigations. The mixing of the contrast with the intestinal content results in contrast impregnated stool, the tagged feces. The degree of fecal tagging was good in the majority of the patients and the colonic segments, especially in the descending colon and sigmoid. Furthermore, patient acceptance and preference were clearly in favour of VCTC compared with CC merely because of the non-invasiveness of the dry preparation. Dry bowel preparation and VCTC is a promising approach towards a patient-friendly colon cancer-screening setup. (orig.)

  2. The effect of computer-aided detection markers on visual search and reader performance during concurrent reading of CT colonography

    International Nuclear Information System (INIS)

    Helbren, Emma; Taylor, Stuart A.; Fanshawe, Thomas R.; Mallett, Susan; Phillips, Peter; Boone, Darren; Gale, Alastair; Altman, Douglas G.; Manning, David; Halligan, Steve

    2015-01-01

    We aimed to identify the effect of computer-aided detection (CAD) on visual search and performance in CT Colonography (CTC) of inexperienced and experienced readers. Fifteen endoluminal CTC examinations were recorded, each with one polyp, and two videos were generated, one with and one without a CAD mark. Forty-two readers (17 experienced, 25 inexperienced) interpreted the videos during infrared visual search recording. CAD markers and polyps were treated as regions of interest in data processing. This multi-reader, multi-case study was analysed using multilevel modelling. CAD drew readers' attention to polyps faster, accelerating identification times: median 'time to first pursuit' was 0.48 s (IQR 0.27 to 0.87 s) with CAD, versus 0.58 s (IQR 0.35 to 1.06 s) without. For inexperienced readers, CAD also held visual attention for longer. All visual search metrics used to assess visual gaze behaviour demonstrated statistically significant differences when ''with'' and ''without'' CAD were compared. A significant increase in the number of correct polyp identifications across all readers was seen with CAD (74 % without CAD, 87 % with CAD; p < 0.001). CAD significantly alters visual search and polyp identification in readers viewing three-dimensional endoluminal CTC. For polyp and CAD marker pursuit times, CAD generally exerted a larger effect on inexperienced readers. (orig.)

  3. The effect of computer-aided detection markers on visual search and reader performance during concurrent reading of CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Helbren, Emma; Taylor, Stuart A. [University College London, Centre for Medical Imaging, London (United Kingdom); Fanshawe, Thomas R.; Mallett, Susan [University of Oxford, Nuffield Department of Primary Care Health Sciences, Oxford (United Kingdom); Phillips, Peter [University of Cumbria, Health and Medical Sciences Group, Lancaster (United Kingdom); Boone, Darren [Colchester Hospital University NHS Foundation Trust and Anglia University, Colchester (United Kingdom); Gale, Alastair [Loughborough University, Applied Vision Research Centre, Loughborough (United Kingdom); Altman, Douglas G. [University of Oxford, Centre for Statistics in Medicine, Oxford (United Kingdom); Manning, David [Lancaster University, Lancaster Medical School, Faculty of Health and Medicine, Lancaster (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College Hospital, Gastrointestinal Radiology, University College London, Centre for Medical Imaging, Podium Level 2, London, NW1 2BU (United Kingdom)

    2015-06-01

    We aimed to identify the effect of computer-aided detection (CAD) on visual search and performance in CT Colonography (CTC) of inexperienced and experienced readers. Fifteen endoluminal CTC examinations were recorded, each with one polyp, and two videos were generated, one with and one without a CAD mark. Forty-two readers (17 experienced, 25 inexperienced) interpreted the videos during infrared visual search recording. CAD markers and polyps were treated as regions of interest in data processing. This multi-reader, multi-case study was analysed using multilevel modelling. CAD drew readers' attention to polyps faster, accelerating identification times: median 'time to first pursuit' was 0.48 s (IQR 0.27 to 0.87 s) with CAD, versus 0.58 s (IQR 0.35 to 1.06 s) without. For inexperienced readers, CAD also held visual attention for longer. All visual search metrics used to assess visual gaze behaviour demonstrated statistically significant differences when ''with'' and ''without'' CAD were compared. A significant increase in the number of correct polyp identifications across all readers was seen with CAD (74 % without CAD, 87 % with CAD; p < 0.001). CAD significantly alters visual search and polyp identification in readers viewing three-dimensional endoluminal CTC. For polyp and CAD marker pursuit times, CAD generally exerted a larger effect on inexperienced readers. (orig.)

  4. Computer-assisted detection of colonic polyps with CT colonography using neural networks and binary classification trees

    International Nuclear Information System (INIS)

    Jerebko, Anna K.; Summers, Ronald M.; Malley, James D.; Franaszek, Marek; Johnson, C. Daniel

    2003-01-01

    Detection of colonic polyps in CT colonography is problematic due to complexities of polyp shape and the surface of the normal colon. Published results indicate the feasibility of computer-aided detection of polyps but better classifiers are needed to improve specificity. In this paper we compare the classification results of two approaches: neural networks and recursive binary trees. As our starting point we collect surface geometry information from three-dimensional reconstruction of the colon, followed by a filter based on selected variables such as region density, Gaussian and average curvature and sphericity. The filter returns sites that are candidate polyps, based on earlier work using detection thresholds, to which the neural nets or the binary trees are applied. A data set of 39 polyps from 3 to 25 mm in size was used in our investigation. For both neural net and binary trees we use tenfold cross-validation to better estimate the true error rates. The backpropagation neural net with one hidden layer trained with Levenberg-Marquardt algorithm achieved the best results: sensitivity 90% and specificity 95% with 16 false positives per study

  5. An improved high order texture features extraction method with application to pathological diagnosis of colon lesions for CT colonography

    Science.gov (United States)

    Song, Bowen; Zhang, Guopeng; Lu, Hongbing; Wang, Huafeng; Han, Fangfang; Zhu, Wei; Liang, Zhengrong

    2014-03-01

    Differentiation of colon lesions according to underlying pathology, e.g., neoplastic and non-neoplastic, is of fundamental importance for patient management. Image intensity based textural features have been recognized as a useful biomarker for the differentiation task. In this paper, we introduce high order texture features, beyond the intensity, such as gradient and curvature, for that task. Based on the Haralick texture analysis method, we introduce a virtual pathological method to explore the utility of texture features from high order differentiations, i.e., gradient and curvature, of the image intensity distribution. The texture features were validated on database consisting of 148 colon lesions, of which 35 are non-neoplastic lesions, using the random forest classifier and the merit of area under the curve (AUC) of the receiver operating characteristics. The results show that after applying the high order features, the AUC was improved from 0.8069 to 0.8544 in differentiating non-neoplastic lesion from neoplastic ones, e.g., hyperplastic polyps from tubular adenomas, tubulovillous adenomas and adenocarcinomas. The experimental results demonstrated that texture features from the higher order images can significantly improve the classification accuracy in pathological differentiation of colorectal lesions. The gain in differentiation capability shall increase the potential of computed tomography (CT) colonography for colorectal cancer screening by not only detecting polyps but also classifying them from optimal polyp management for the best outcome in personalized medicine.

  6. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  7. Comparative study of colorectal carcinoma examination with four postprocessing of CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Mingyue, Luo; Kangrong, Zhou [The 3rd Affilated Hospital Sun Yat-sen Univ. of Medical Sciences, Guangzhou (China). Dept. of Radiology

    2001-10-01

    Objective: To study the clinical value of colorectal carcinoma examination by comparison of different postprocessing techniques such as multiplanar reformation (MPR), CT virtual colonoscopy (CTVC), shaded surface display (SSD) and Raysum. Methods: 64 patients with colorectal carcinomas underwent volume scanning using spiral CT. MPR, CTVC, SSD and Raysum images were obtained by using 4 different software in workstation. All cases were proved by surgical or CC biotic histology. The results were compared and analyzed according to the circumferential extension, length and pathologic patterns of colorectal carcinoma with MPR, CTVC, SSD and Raysum. Results: The correction rate of determination the circumferential extension of colorectal carcinoma with MPR, CTVC, SSD and Raysum were 100.0%, 82.8%, 79.7% and 79.7%, respectively. There was significant statistical difference between MPR and CTVC; The accuracy of judging the length of carcinoma were 89.1%, 76.6%, 95.3% and 100.0%, respectively. There was statistical difference between CTVC and SSD; The accuracy of showing carcinoma pathologic patterns were 81.3%, 92.2%, 71.9% and 71.0%, respectively. There was statistical difference between CTVC and SSD, too. MPR could correctly determine the circumferential extension of colorectal carcinoma. In determination the length of carcinoma, Raysum was more accurate than SSD. CTVC could be more helpful in showing carcinoma pathologic patterns. Conclusion: There were advantages and disadvantages in colorectal carcinoma examination with MPR, CTVC, SSD and Raysum, and the combination could display colorectal carcinoma more completely and comprehensively.

  8. Comparative study of colorectal carcinoma examination with four postprocessing of CT colonography

    International Nuclear Information System (INIS)

    Luo Mingyue; Zhou Kangrong

    2001-01-01

    Objective: To study the clinical value of colorectal carcinoma examination by comparison of different postprocessing techniques such as multiplanar reformation (MPR), CT virtual colonoscopy (CTVC), shaded surface display (SSD) and Raysum. Methods: 64 patients with colorectal carcinomas underwent volume scanning using spiral CT. MPR, CTVC, SSD and Raysum images were obtained by using 4 different software in workstation. All cases were proved by surgical or CC biotic histology. The results were compared and analyzed according to the circumferential extension, length and pathologic patterns of colorectal carcinoma with MPR, CTVC, SSD and Raysum. Results: The correction rate of determination the circumferential extension of colorectal carcinoma with MPR, CTVC, SSD and Raysum were 100.0%, 82.8%, 79.7% and 79.7%, respectively. There was significant statistical difference between MPR and CTVC; The accuracy of judging the length of carcinoma were 89.1%, 76.6%, 95.3% and 100.0%, respectively. There was statistical difference between CTVC and SSD; The accuracy of showing carcinoma pathologic patterns were 81.3%, 92.2%, 71.9% and 71.0%, respectively. There was statistical difference between CTVC and SSD, too. MPR could correctly determine the circumferential extension of colorectal carcinoma. In determination the length of carcinoma, Raysum was more accurate than SSD. CTVC could be more helpful in showing carcinoma pathologic patterns. Conclusion: There were advantages and disadvantages in colorectal carcinoma examination with MPR, CTVC, SSD and Raysum, and the combination could display colorectal carcinoma more completely and comprehensively

  9. A dimension reduction strategy for improving the efficiency of computer-aided detection for CT colonography

    Science.gov (United States)

    Song, Bowen; Zhang, Guopeng; Wang, Huafeng; Zhu, Wei; Liang, Zhengrong

    2013-02-01

    Various types of features, e.g., geometric features, texture features, projection features etc., have been introduced for polyp detection and differentiation tasks via computer aided detection and diagnosis (CAD) for computed tomography colonography (CTC). Although these features together cover more information of the data, some of them are statistically highly-related to others, which made the feature set redundant and burdened the computation task of CAD. In this paper, we proposed a new dimension reduction method which combines hierarchical clustering and principal component analysis (PCA) for false positives (FPs) reduction task. First, we group all the features based on their similarity using hierarchical clustering, and then PCA is employed within each group. Different numbers of principal components are selected from each group to form the final feature set. Support vector machine is used to perform the classification. The results show that when three principal components were chosen from each group we can achieve an area under the curve of receiver operating characteristics of 0.905, which is as high as the original dataset. Meanwhile, the computation time is reduced by 70% and the feature set size is reduce by 77%. It can be concluded that the proposed method captures the most important information of the feature set and the classification accuracy is not affected after the dimension reduction. The result is promising and further investigation, such as automatically threshold setting, are worthwhile and are under progress.

  10. Measurement of smaller colon polyp in CT colonography images using morphological image processing.

    Science.gov (United States)

    Manjunath, K N; Siddalingaswamy, P C; Prabhu, G K

    2017-11-01

    Automated measurement of the size and shape of colon polyps is one of the challenges in Computed tomography colonography (CTC). The objective of this retrospective study was to improve the sensitivity and specificity of smaller polyp measurement in CTC using image processing techniques. A domain knowledge-based method has been implemented with hybrid method of colon segmentation, morphological image processing operators for detecting the colonic structures, and the decision-making system for delineating the smaller polyp-based on a priori knowledge. The method was applied on 45 CTC dataset. The key finding was that the smaller polyps were accurately measured. In addition to 6-9 mm range, polyps of even processing. It takes [Formula: see text] min for measuring the smaller polyp in a dataset of 500 CTC images. With this method, [Formula: see text] and [Formula: see text] were achieved. The domain-based approach with morphological image processing has given good results. The smaller polyps were measured accurately which helps in making right clinical decisions. Qualitatively and quantitatively the results were acceptable when compared to the ground truth at [Formula: see text].

  11. Colon distension, perceived burden and side-effects of CT-colonography for screening using hyoscine butylbromide or glucagon hydrochloride as bowel relaxant

    International Nuclear Information System (INIS)

    Haan, Margriet C. de; Boellaard, Thierry N.; Bossuyt, Patrick M.; Stoker, Jaap

    2012-01-01

    Objective: Compare colonic distension and perceived burden of CT-colonography between participants receiving hyoscine butylbromide (buscopan) and glucagon hydrochloride as bowel relaxant. Materials and methods: Data were collected within a screening trial. Participants received 20 mg buscopan intravenously or 1 mg of glucagon intravenously (if buscopan contra-indicated). Colon distension per segment was assessed using a 4-point scale (prone and supine). Data on perceived burden of CT-colonography were collected using a questionnaire two weeks after the examination. Outcome measures between groups were compared using propensity score matching. We used a stratified Wilcoxon–Mann–Whitney test statistic for quantitative and Cochran–Mantel–Haenszel statistics for categorical variables. Results: 541 participants were included: 336 (62%) received buscopan and 205 received glucagon. All buscopan recipients had an adequately distended colon, compared to 96% in the glucagon group (RR 7.31, 95% CI: 1.61–33.28). More glucagon recipients scored the insufflation as rather or extremely burdensome (25% vs. 16%; overall mean score 2.7 vs. 2.4; p < 0.001) and more found the entire CT-colonography rather or extremely burdensome (14% vs. 7%; 2.2 vs. 1.9; p = 0.001). Most frequently reported side effects were a dry mouth in the buscopan group (15%) and nausea in the glucagon group (13%). Conclusion: Compared to glucagon, premedication with buscopan results in significantly more adequately distended colons and a less burdensome procedure. When buscopan can be used, it is the preferred bowel relaxant.

  12. Colon distension, perceived burden and side-effects of CT-colonography for screening using hyoscine butylbromide or glucagon hydrochloride as bowel relaxant

    Energy Technology Data Exchange (ETDEWEB)

    Haan, Margriet C. de, E-mail: margrietcdehaan@gmail.com [Department of Radiology, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Boellaard, Thierry N., E-mail: t.n.boellaard@amc.uva.nl [Department of Radiology, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Bossuyt, Patrick M., E-mail: p.m.bossuyt@amc.uva.nl [Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Stoker, Jaap, E-mail: j.stoker@amc.uva.nl [Department of Radiology, Academic Medical Centre, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2012-08-15

    Objective: Compare colonic distension and perceived burden of CT-colonography between participants receiving hyoscine butylbromide (buscopan) and glucagon hydrochloride as bowel relaxant. Materials and methods: Data were collected within a screening trial. Participants received 20 mg buscopan intravenously or 1 mg of glucagon intravenously (if buscopan contra-indicated). Colon distension per segment was assessed using a 4-point scale (prone and supine). Data on perceived burden of CT-colonography were collected using a questionnaire two weeks after the examination. Outcome measures between groups were compared using propensity score matching. We used a stratified Wilcoxon-Mann-Whitney test statistic for quantitative and Cochran-Mantel-Haenszel statistics for categorical variables. Results: 541 participants were included: 336 (62%) received buscopan and 205 received glucagon. All buscopan recipients had an adequately distended colon, compared to 96% in the glucagon group (RR 7.31, 95% CI: 1.61-33.28). More glucagon recipients scored the insufflation as rather or extremely burdensome (25% vs. 16%; overall mean score 2.7 vs. 2.4; p < 0.001) and more found the entire CT-colonography rather or extremely burdensome (14% vs. 7%; 2.2 vs. 1.9; p = 0.001). Most frequently reported side effects were a dry mouth in the buscopan group (15%) and nausea in the glucagon group (13%). Conclusion: Compared to glucagon, premedication with buscopan results in significantly more adequately distended colons and a less burdensome procedure. When buscopan can be used, it is the preferred bowel relaxant.

  13. Appearances of screen-detected versus symptomatic colorectal cancers at CT colonography

    International Nuclear Information System (INIS)

    Plumb, Andrew A.; Pathiraja, Fiona; Taylor, Stuart A.; Halligan, Steve; Nickerson, Claire; Wooldrage, Katherine; Atkin, Wendy S.; Burling, David

    2016-01-01

    The aim of this study was to compare the morphology, radiological stage, conspicuity, and computer-assisted detection (CAD) characteristics of colorectal cancers (CRC) detected by computed tomographic colonography (CTC) in screening and symptomatic populations. Two radiologists independently analyzed CTC images from 133 patients diagnosed with CRC in (a) two randomized trials of symptomatic patients (35 patients with 36 tumours) and (b) a screening program using fecal occult blood testing (FOBt; 98 patients with 100 tumours), measuring tumour length, volume, morphology, radiological stage, and subjective conspicuity. A commercial CAD package was applied to both datasets. We compared CTC characteristics between screening and symptomatic populations with multivariable regression. Screen-detected CRC were significantly smaller (mean 3.0 vs 4.3 cm, p < 0.001), of lower volume (median 9.1 vs 23.2 cm 3 , p < 0.001) and more frequently polypoid (34/100, 34 % vs. 5/36, 13.9 %, p = 0.02) than symptomatic CRC. They were of earlier stage than symptomatic tumours (OR = 0.17, 95 %CI 0.07-0.41, p < 0.001), and were judged as significantly less conspicuous (mean conspicuity 54.1/100 vs. 72.8/100, p < 0.001). CAD detection was significantly lower for screen-detected (77.4 %; 95 %CI 67.9-84.7 %) than symptomatic CRC (96.9 %; 95 %CI 83.8-99.4 %, p = 0.02). Screen-detected CRC are significantly smaller, more frequently polypoid, subjectively less conspicuous, and less likely to be identified by CAD than those in symptomatic patients. (orig.)

  14. Reducing the oral contrast dose in CT colonography: evaluation of faecal tagging quality and patient acceptance

    International Nuclear Information System (INIS)

    Liedenbaum, M.H.; Denters, M.J.; Zijta, F.M.; Ravesteijn, V.F. van; Bipat, S.; Vos, F.M.; Dekker, E.; Stoker, J.

    2011-01-01

    Aim: To evaluate the minimal iodine contrast medium load necessary for an optimal computed tomography colonography tagging quality. Materials and Methods: Faecal occult blood test positive patients were randomly selected for one of three iodine bowel preparations: (1) 3 x 50 ml meglumine ioxithalamate (45 g iodine), (2) 4 x 25 ml meglumine ioxithalamate (30 g iodine); or (3) 3 x 25 ml (22.5 g iodine) meglumine ioxithalamate. Two experienced readers assessed the tagging quality per colonic segment on a five-point scale and the presence of adherent stool. Also semi-automatic homogeneity measurements were performed. Patient acceptance was assessed with questionnaires. Results: Of 70 eligible patients, 45 patients participated (25 males, mean age 62 years). Each preparation group contained 15 patients. The quality of tagging was insufficient (score 1-2) in 0% of segments in group 1; 4% in group 2 (p < 0.01 versus group 1); and 5% in group 3 (p = 0.06 versus group 1). In group 1 in 11% of the segments adherent stool was present compared with 49% in group 2 and 41% in group 3 (p < 0.01, group 2 and 3 versus group 1). Homogeneity was 85, 102 (p < 0.01), and 91 SD HU (p = 0.26) in groups 1, 2, and 3, respectively. In group 1 two patients experienced no burden after contrast agent ingestion compared to one patient in group 2 and nine patients in group 3 (p = 0.017). Conclusion: A dose of 3 x 50 ml meglumine ioxithalamate is advisable for an optimal tagging quality despite beneficial effects on the patient acceptance in patients receiving a lower dose.

  15. CT colonography: accuracy of initial interpretation by radiographers in routine clinical practice

    International Nuclear Information System (INIS)

    Burling, D.; Wylie, P.; Gupta, A.; Illangovan, R.; Muckian, J.; Ahmad, R.; Marshall, M.; Taylor, S.A.

    2010-01-01

    Aim: To investigate performance of computed-assisted detection (CAD)-assisted radiographers interpreting computed tomography colonography (CTC) in routine practice. Materials and methods: Three hundred and three consecutive symptomatic patients underwent CTC. Examinations were double-read by trained radiographers using primary two-dimensional/three-dimensional (2D/3D) analysis supplemented by 'second reader' CAD. Radiographers recorded colonic neoplasia, interpretation times, and patient management strategy code (S0, inadequate; S1, normal; S2, 6-9 mm polyp; S3, ≥10 mm polyp; S4, cancer; S5, diverticular stricture) for each examination. Strategies were compared to the reference standard using kappa statistic, interpretation times using paired t-test, learning curves using logistic regression and Pearson's correlation coefficient. Results: Of 303 examinations, 69 (23%) were abnormal. CAD-assisted radiographers detected 17/17 (100%) cancers, 21/28 (72%) polyps ≥10 mm and 42/60 (70%) 6-9 mm polyps. The overall agreement between radiographers and the reference management strategy was good (kappa 0.72; CI: 0.65, 0.78) with agreement for S1 strategy in 189/211 (90%) exams; S2 in 19/27 (70%); S3 in 12/19 (63%); S4 in 17/17 (100%); S5 in 5/6 (83%). The mean interpretation time was 17 min (SD = 11) compared with 8 min (SD = 3.5) for radiologists. There was no learning curve for recording correct strategies (OR 0.88; p = 0.12) but a significant reduction in interpretation times, mean 14 and 31 min (last/first 50 exams; -0.46; p < 0.001). Conclusion: Routine CTC interpretation by radiographers is effective for initial triage of patients with cancer, but independent reporting is currently not recommended.

  16. Appearances of screen-detected versus symptomatic colorectal cancers at CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Pathiraja, Fiona; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); Nickerson, Claire [Fulwood House, Public Health England, Sheffield (United Kingdom); Wooldrage, Katherine; Atkin, Wendy S. [Imperial College London, Department of Surgery and Cancer, London (United Kingdom); Burling, David [St Mark' s Hospital, Intestinal Imaging Centre, Harrow (United Kingdom)

    2016-12-15

    The aim of this study was to compare the morphology, radiological stage, conspicuity, and computer-assisted detection (CAD) characteristics of colorectal cancers (CRC) detected by computed tomographic colonography (CTC) in screening and symptomatic populations. Two radiologists independently analyzed CTC images from 133 patients diagnosed with CRC in (a) two randomized trials of symptomatic patients (35 patients with 36 tumours) and (b) a screening program using fecal occult blood testing (FOBt; 98 patients with 100 tumours), measuring tumour length, volume, morphology, radiological stage, and subjective conspicuity. A commercial CAD package was applied to both datasets. We compared CTC characteristics between screening and symptomatic populations with multivariable regression. Screen-detected CRC were significantly smaller (mean 3.0 vs 4.3 cm, p < 0.001), of lower volume (median 9.1 vs 23.2 cm{sup 3}, p < 0.001) and more frequently polypoid (34/100, 34 % vs. 5/36, 13.9 %, p = 0.02) than symptomatic CRC. They were of earlier stage than symptomatic tumours (OR = 0.17, 95 %CI 0.07-0.41, p < 0.001), and were judged as significantly less conspicuous (mean conspicuity 54.1/100 vs. 72.8/100, p < 0.001). CAD detection was significantly lower for screen-detected (77.4 %; 95 %CI 67.9-84.7 %) than symptomatic CRC (96.9 %; 95 %CI 83.8-99.4 %, p = 0.02). Screen-detected CRC are significantly smaller, more frequently polypoid, subjectively less conspicuous, and less likely to be identified by CAD than those in symptomatic patients. (orig.)

  17. Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Sarit Badiani, Sarit; Karandikar, Sharad [Dept. of General Surgery, Heart of England Foundation Trust, Birmingham (United Kingdom); Tomas-Hernandez, Silvia; Roy-Choudhury; Shuvro [Dept. of Radiology, Heart of England Foundation Trust, Birmingham (United Kingdom)], e-mail: shurvrorc@googlemail.com

    2013-10-15

    Background: Computed tomographic colonography (CTC) is now an established method for imaging the colon and rectum in the screening and symptomatic setting. Additional benefit of CTC is the ability to assess for extracolonic findings especially in patients presenting with colorectal symptoms. Purpose: To determine prevalence of extracolonic findings (ECF) in symptomatic patients undergoing CTC and determine accuracy of CTC for exclusion of significant abdominal disease and extracolonic malignancy (ECM). Material and Methods: A total of 1359 unenhanced prone and postcontrast supine CTC studies were performed between March 2002 and December 2007. ECF were retrospectively classified according to C-RADS criteria into E1 to E4 findings. For ECM, a gold standard of clinical and/or radiological follow-up supplemented with data from the regional cancer registry with a median follow-up of 42 months was created. Sensitivity and negative predictive values for ECM was calculated. Results: Following exclusions, 1177 CTCs were analyzed. Of 1423 extracolonic findings reported, 328/1423 (23%) E3 and 100/1423 (7%) E4 (including six eventual FP studies) findings were identified. Thirty-two ECMs were confirmed following further investigations. Seven further small ECMs were detected during the entire follow-up, of which two were potentially visible in retrospect (false-negative studies). Additional tests were generated from 55/1177 (4.7%) studies. Sensitivity and negative predictive value for ECM was 94.1% (95% CI 78.9 - 98.9%) and 99.8% (95% CI 99.3 - 99.9%), respectively. Conclusion: One in 37 patients were found to have an ECM. Two potentially detectable cancers were missed. Only a small proportion of patients underwent additional work-up.

  18. Extracolonic findings (ECF) on CT colonography (CTC) in patients presenting with colorectal symptoms.

    Science.gov (United States)

    Badiani, Sarit; Tomas-Hernandez, Silvia; Karandikar, Sharad; Roy-Choudhury, Shuvro

    2013-10-01

    Computed tomographic colonography (CTC) is now an established method for imaging the colon and rectum in the screening and symptomatic setting. Additional benefit of CTC is the ability to assess for extracolonic findings especially in patients presenting with colorectal symptoms. To determine prevalence of extracolonic findings (ECF) in symptomatic patients undergoing CTC and determine accuracy of CTC for exclusion of significant abdominal disease and extracolonic malignancy (ECM). A total of 1359 unenhanced prone and postcontrast supine CTC studies were performed between March 2002 and December 2007. ECF were retrospectively classified according to C-RADS criteria into E1 to E4 findings. For ECM, a gold standard of clinical and/or radiological follow-up supplemented with data from the regional cancer registry with a median follow-up of 42 months was created. Sensitivity and negative predictive values for ECM was calculated. Following exclusions, 1177 CTCs were analyzed. Of 1423 extracolonic findings reported, 328/1423 (23%) E3 and 100/1423 (7%) E4 (including six eventual FP studies) findings were identified. Thirty-two ECMs were confirmed following further investigations. Seven further small ECMs were detected during the entire follow-up, of which two were potentially visible in retrospect (false-negative studies). Additional tests were generated from 55/1177 (4.7%) studies. Sensitivity and negative predictive value for ECM was 94.1% (95% CI 78.9-98.9%) and 99.8% (95% CI 99.3-99.9%), respectively. One in 37 patients were found to have an ECM. Two potentially detectable cancers were missed. Only a small proportion of patients underwent additional work-up.

  19. Magnetic resonance colonography with limited bowel preparation: a comparison of three strategies

    NARCIS (Netherlands)

    Florie, Jasper; van Gelder, Rogier E.; Haberkorn, Brigitte; Birnie, Erwin; Lavini, Cristina; Reitsma, Johannes B.; Stoker, Jaap

    2007-01-01

    PURPOSE: To prospectively compare three strategies of magnetic resonance colonography (MRC) with fecal tagging. MATERIALS AND METHODS: Three strategies were compared: (S1) gadolinium as oral tagging agent and a gadolinium-water mixture for rectal filling (bright lumen), (S2) oral barium and water

  20. Assessment of the Incremental Benefit of Computer-Aided Detection (CAD) for Interpretation of CT Colonography by Experienced and Inexperienced Readers

    Science.gov (United States)

    Boone, Darren; Mallett, Susan; McQuillan, Justine; Taylor, Stuart A.; Altman, Douglas G.; Halligan, Steve

    2015-01-01

    Objectives To quantify the incremental benefit of computer-assisted-detection (CAD) for polyps, for inexperienced readers versus experienced readers of CT colonography. Methods 10 inexperienced and 16 experienced radiologists interpreted 102 colonography studies unassisted and with CAD utilised in a concurrent paradigm. They indicated any polyps detected on a study sheet. Readers’ interpretations were compared against a ground-truth reference standard: 46 studies were normal and 56 had at least one polyp (132 polyps in total). The primary study outcome was the difference in CAD net benefit (a combination of change in sensitivity and change in specificity with CAD, weighted towards sensitivity) for detection of patients with polyps. Results Inexperienced readers’ per-patient sensitivity rose from 39.1% to 53.2% with CAD and specificity fell from 94.1% to 88.0%, both statistically significant. Experienced readers’ sensitivity rose from 57.5% to 62.1% and specificity fell from 91.0% to 88.3%, both non-significant. Net benefit with CAD assistance was significant for inexperienced readers but not for experienced readers: 11.2% (95%CI 3.1% to 18.9%) versus 3.2% (95%CI -1.9% to 8.3%) respectively. Conclusions Concurrent CAD resulted in a significant net benefit when used by inexperienced readers to identify patients with polyps by CT colonography. The net benefit was nearly four times the magnitude of that observed for experienced readers. Experienced readers did not benefit significantly from concurrent CAD. PMID:26355745

  1. Effect of reducing abdominal compression during prone CT colonography on ascending colonic rotation during supine-to-prone positional change

    International Nuclear Information System (INIS)

    Jang, Jong eon; Park, Seong Ho; Lee, Jong Seok; Kim, Hyun Jin; KIm, Ah Young; Ha, Hyun Kwon

    2016-01-01

    To determine the effect of reduced abdominal compression in prone position on ascending colonic movement during supine-to-prone positional change during CT colonography (CTC). Eighteen consecutive patients who had undergone prone CTC scanning with cushion blocks placed under the chest and hip/thigh to reduce abdominal compression and had confirmed sessile polyps ≥ 6 mm in the well-distended, straight, mid-ascending colon, were included. Radial location along the ascending colonic luminal circumference (°) was measured for 24 polyps and 54 colonic teniae on supine and prone CTC images. The supine-to-prone change ranging between -180° and +180° (- and + for internal and external colonic rotations, respectively), was determined. In addition, possible causes of any ascending colonic rotations were explored. Abdominal compression during prone CTC scanning completely disappeared with the use of cushion blocks in 17 of 18 patients. However, some degrees of ascending colonic rotation were still observed, with the radial location changes of -22° to 61° (median, 13.9°) for the polyps and similar degrees for teniae. Fifty-four percent and 56% of polyps and teniae, respectively, showed changes > 10°. The radial location change of the polyps was significantly associated with the degree of anterior shift of the small bowel and mesentery (r = 0.722, p < 0.001) and the degree of posterior displacement of the ascending colon (r = 0.566, p = 0.004) during supine-to-prone positional change. Ascending colonic rotation upon supine-to-prone positional change during CTC, mostly in the form of external rotation, is not eliminated by removing abdominal compression in prone position

  2. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, Division of Medicine, London (United Kingdom); Ghanouni, Alex; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Rees, Colin J. [Durham University School of Medicine, Pharmacy and Health, Durham (United Kingdom); Hewitson, Paul [University of Oxford, Health Services Research Unit, Nuffield Department of Population Health, Oxford (United Kingdom); Nickerson, Claire; Wright, Suzanne [Fulwood House, NHS Cancer Screening Programmes, Sheffield (United Kingdom)

    2017-03-15

    To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as complications. CTC and colonoscopy responses were compared using multilevel logistic regression. Of 67,114 subjects identified, 52,805 (79 %) responded. Understanding of test risks was lower for CTC (1712/1970 = 86.9 %) than colonoscopy (48783/50975 = 95.7 %, p < 0.0001). Overall, a slightly greater proportion of screenees found CTC unexpectedly uncomfortable (506/1970 = 25.7 %) than colonoscopy (10,705/50,975 = 21.0 %, p < 0.0001). CTC was tolerated well as a completion procedure for failed colonoscopy (unexpected discomfort; CTC = 26.3 %: colonoscopy = 57.0 %, p < 0.001). Post-procedural pain was equally common (CTC: 288/1970,14.6 %, colonoscopy: 7544/50,975,14.8 %; p = 0.55). Adverse event rates were similar in both groups (CTC: 20/2947 = 1.2 %; colonoscopy: 683/64,312 = 1.1 %), but generally less serious with CTC. Even though CTC was reserved for individuals either unsuitable for or unable to complete colonoscopy, we found only small differences in test-related discomfort. CTC was well tolerated as a completion procedure and was extremely safe. CTC can be delivered across a national screening programme with high patient satisfaction. (orig.)

  3. Detection of colorectal masses in CT colonography: application of deep residual networks for differentiating masses from normal colon anatomy

    Science.gov (United States)

    Näppi, Janne J.; Hironaka, Toru; Yoshida, Hiroyuki

    2018-02-01

    Even though the clinical consequences of a missed colorectal cancer far outweigh those of a missed polyp, there has been little work on computer-aided detection (CADe) for colorectal masses in CT colonography (CTC). One of the problems is that it is not clear how to manually design mathematical image-based features that could be used to differentiate effectively between masses and certain types of normal colon anatomy such as ileocecal valves (ICVs). Deep learning has demonstrated ability to automatically determine effective discriminating features in many image-based problems. Recently, residual networks (ResNets) were developed to address the practical problems of constructing deep network architectures for optimizing the performance of deep learning. In this pilot study, we compared the classification performance of a conventional 2D-convolutional ResNet (2D-ResNet) with that of a volumetric 3D-convolutional ResNet (3D-ResNet) in differentiating masses from normal colon anatomy in CTC. For the development and evaluation of the ResNets, 695 volumetric images of biopsy-proven colorectal masses, ICVs, haustral folds, and rectal tubes were sampled from 196 clinical CTC cases and divided randomly into independent training, validation, and test datasets. The training set was expanded by use of volumetric data augmentation. Our preliminary results on the 140 test samples indicate that it is feasible to train a deep volumetric 3D-ResNet for performing effective image-based discriminations in CTC. The 3D-ResNet slightly outperformed the 2D-ResNet in the discrimination of masses and normal colon anatomy, but the statistical difference between their very high classification accuracies was not significant. The highest classification accuracy was obtained by combining the mass-likelihood estimates of the 2D- and 3D-ResNets, which enabled correct classification of all of the masses.

  4. Simethicone to prevent colonic bubbles during CT colonography performed with polyethylene glycol lavage and iohexol tagging: a randomized clinical trial.

    Science.gov (United States)

    Hong, Gil-Sun; Park, Seong Ho; Kim, Bohyun; Lee, Ju Hee; Kim, Jin Cheon; Yu, Chang Sik; Baek, Seunghee; Lee, Jong Seok; Kim, Hyun Jin

    2015-04-01

    The purpose of this study was to determine whether the occurrence of numerous colonic bubbles during CT colonography (CTC) performed with polyethylene glycol cleansing and oral iohexol fecal/fluid tagging could be prevented by use of simethicone. Adults with suspected colonic neoplasia who had been randomly assigned to control and simethicone intervention groups underwent CTC after cleansing with 4 L of polyethylene glycol, tagging with 50 mL of 350 mg I/mL oral iohexol, and without (control) or with (intervention) oral administration of 200 mg of simethicone. Colonic segments in the control and intervention groups were evaluated for amount of colonic bubbles during CTC. A 6-point grading system was used in which 0 indicated no bubbles and 5 indicated that more than three fourths of the air-distended mucosa was covered with bubbles. The primary endpoint was a per-patient colonic bubble grade, derived as an average of the segmental grades. Eighty adults with suspected colonic neoplasia were randomly assigned to the control (40 patients) and simethicone intervention (40 patients) groups. A total of 659 colonic segments in the control group and 689 segments in the intervention group were evaluated for amount of colonic bubbles during CTC. The per-patient colonic bubble score was significantly lower in the simethicone intervention group than in the control group. The mean score was 0.0±0.1 (SD) versus 1.2±0.8 (pgrade 0, and 16 (2.3%) were grade 1. In contrast, in the control group, 226 (34.3%) segments were grade 0; 173 (26.3%), grade 1; 175 (26.6%), grade 2; 45 (6.8%), grade 3; 23 (3.5%), grade 4; and 17 (2.6%), grade 5. The colonic bubbles associated with fecal/fluid tagging with iohexol can be successfully prevented by adding simethicone to the colonic preparation.

  5. Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen.

    Science.gov (United States)

    Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy

    2003-10-01

    To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003

  6. Effect of listening to music and essential oil inhalation on patients undergoing screening CT colonography: A randomized controlled trial

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Koichi, E-mail: Nagata7@aol.com [Department of Radiology, Kameda Medical Center, 929 Higashi-cho, Kamogawa, Chiba 296-8602 (Japan); Department of Radiology, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Cancer Screening Technology Division, Research Center for Cancer Prevention and Screening, National Cancer Center, 5-1-1, Tsukiji, Chuo-ku, Tokyo 104-0045 (Japan); Iida, Nao, E-mail: n.iida-xray@kameda.jp [Department of Radiology, Kameda Medical Center Makuhari, 1-3, Nakase, Mihama-ku, Chiba 261-8501 (Japan); Kanazawa, Hidenori, E-mail: r0713hk@jichi.ac.jp [Department of Radiology, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Fujiwara, Masanori, E-mail: m_fujiwara@kameda.jp [Department of Radiology, Kameda Medical Center Makuhari, 1-3, Nakase, Mihama-ku, Chiba 261-8501 (Japan); Mogi, Tomohiro, E-mail: mogi-xray@kameda.jp [Department of Radiology, Kameda Medical Center Makuhari, 1-3, Nakase, Mihama-ku, Chiba 261-8501 (Japan); Mitsushima, Toru, E-mail: mitsushima@kameda.jp [Department of Gastroenterology, Kameda Medical Center Makuhari, 1-3, Nakase, Mihama-ku, Chiba 261-8501 (Japan); Lefor, Alan T., E-mail: alefor@jichi.ac.jp [Department of Surgery, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan); Sugimoto, Hideharu, E-mail: sugimoto@jichi.ac.jp [Department of Radiology, Jichi Medical University, 3311-1 Yakushiji, Shimotsuke, Tochigi 329-0498 (Japan)

    2014-12-15

    Highlights: • Music does not decrease patients’ perceived pain or acceptance during CTC. • Aromatherapy does not affect patients’ perceived pain or experience during CTC. • Music and aroma had little effect on vital signs during CTC. • More participants who listened to music requested music during the next CTC. • More participants who inhaled aroma requested aroma during the next CTC. - Abstract: Objective: To prospectively evaluate the effect of listening to music and inhaling aroma oil on patients undergoing screening computed tomography colonography. Materials and methods: Two hundred and twenty four participants were randomly allocated to one of the four groups including: (1) combined music and aroma, (2) music alone, (3) aroma alone, and (4) control. The visual analog scale for pain and a questionnaire were used for subjective outcomes. We also used a pre-test–post-test design to compare the differences in blood pressure and heart rate as objective outcomes. Results: There were no statistical differences between the control group and other groups in the visual analog scale or changes in heart rate. Changes in blood pressure were similar. Participants reported good overall experiences. There were no differences in terms of overall satisfaction, pain rating, willingness to repeat the computed tomography colonography procedure in the future, or preference between colonoscopy and computed tomography colonography. More participants using music and/or aroma requested music and/or aroma during the next computed tomography colonography (P < 0.0001). Conclusion: Although audio and olfactory intervention had little effect on perceived pain or discomfort and vital signs, participants who listened to music and inhaled aroma during the computed tomography colonography preferred music and aroma during the next computed tomography colonography.

  7. Effect of listening to music and essential oil inhalation on patients undergoing screening CT colonography: A randomized controlled trial

    International Nuclear Information System (INIS)

    Nagata, Koichi; Iida, Nao; Kanazawa, Hidenori; Fujiwara, Masanori; Mogi, Tomohiro; Mitsushima, Toru; Lefor, Alan T.; Sugimoto, Hideharu

    2014-01-01

    Highlights: • Music does not decrease patients’ perceived pain or acceptance during CTC. • Aromatherapy does not affect patients’ perceived pain or experience during CTC. • Music and aroma had little effect on vital signs during CTC. • More participants who listened to music requested music during the next CTC. • More participants who inhaled aroma requested aroma during the next CTC. - Abstract: Objective: To prospectively evaluate the effect of listening to music and inhaling aroma oil on patients undergoing screening computed tomography colonography. Materials and methods: Two hundred and twenty four participants were randomly allocated to one of the four groups including: (1) combined music and aroma, (2) music alone, (3) aroma alone, and (4) control. The visual analog scale for pain and a questionnaire were used for subjective outcomes. We also used a pre-test–post-test design to compare the differences in blood pressure and heart rate as objective outcomes. Results: There were no statistical differences between the control group and other groups in the visual analog scale or changes in heart rate. Changes in blood pressure were similar. Participants reported good overall experiences. There were no differences in terms of overall satisfaction, pain rating, willingness to repeat the computed tomography colonography procedure in the future, or preference between colonoscopy and computed tomography colonography. More participants using music and/or aroma requested music and/or aroma during the next computed tomography colonography (P < 0.0001). Conclusion: Although audio and olfactory intervention had little effect on perceived pain or discomfort and vital signs, participants who listened to music and inhaled aroma during the computed tomography colonography preferred music and aroma during the next computed tomography colonography

  8. MR colonography with fecal tagging: comparison between 2D turbo FLASH and 3D FLASH sequences

    International Nuclear Information System (INIS)

    Papanikolaou, Nickolas; Grammatikakis, John; Maris, Thomas; Prassopoulos, Panos; Gourtsoyiannis, Nicholas; Lauenstein, Thomas

    2003-01-01

    The objective of this study was to compare inversion recovery turbo 2D fast low-angle shot (FLASH) and 3D FLASH sequences for fecal-tagged MR colonography studies. Fifteen consecutive patients with indications for colonoscopy underwent MR colonography with fecal tagging. An inversion recovery turbo-FLASH sequence was applied and compared in terms of artifacts presence, efficiency for masking residual stool, and colonic wall conspicuity with a fat-saturated 3D FLASH sequence. Both sequences were acquired following administration of paramagnetic contrast agent. Contrast-to-noise ratio and relative contrast between colonic wall and lumen were calculated and compared for both sequences. Turbo 2D FLASH provided fewer artifacts, higher efficiency for masking the residual stool, and colonic wall conspicuity equivalent to 3D FLASH. An inversion time of 10 ms provided homogeneously low signal intensity of the colonic lumen. Contrast to noise between colonic wall and lumen was significantly higher in the 3D FLASH images, whereas differences in relative contrast were not statistically significant. An optimized inversion-recovery 2D turbo-FLASH sequence provides better fecal tagging results and should be added to the 3D FLASH sequence when designing dark-lumen MR colonography examination protocols. (orig.)

  9. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Sun [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Kim, Se Hyung, E-mail: shkim7071@gmail.com [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of); Im, Jong Pil; Kim, Sang Gyun [Department of Internal Medicine, Seoul National University Hospital (Korea, Republic of); Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn [Department of Radiology, Seoul National University Hospital (Korea, Republic of); Institute of Radiation Medicine, Seoul National University Hospital (Korea, Republic of)

    2015-04-15

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  10. Effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low dose CT colonography

    International Nuclear Information System (INIS)

    Lee, Eun Sun; Kim, Se Hyung; Im, Jong Pil; Kim, Sang Gyun; Shin, Cheong-il; Han, Joon Koo; Choi, Byung Ihn

    2015-01-01

    Highlights: •We assessed the effect of reconstruction algorithms on CAD in ultra-low dose CTC. •30 patients underwent ultra-low dose CTC using 120 and 100 kVp with 10 mAs. •CT was reconstructed with FBP, ASiR and Veo and then, we applied a CAD system. •Per-polyp sensitivity of CAD in ULD CT can be improved with the IR algorithms. •Despite of an increase in the number of FPs with IR, it was still acceptable. -- Abstract: Purpose: To assess the effect of different reconstruction algorithms on computer-aided diagnosis (CAD) performance in ultra-low-dose CT colonography (ULD CTC). Materials and methods: IRB approval and informed consents were obtained. Thirty prospectively enrolled patients underwent non-contrast CTC at 120 kVp/10 mAs in supine and 100 kVp/10 mAs in prone positions, followed by same-day colonoscopy. Images were reconstructed with filtered back projection (FBP), 80% adaptive statistical iterative reconstruction (ASIR80), and model-based iterative reconstruction (MBIR). A commercial CAD system was applied and per-polyp sensitivities and numbers of false-positives (FPs) were compared among algorithms. Results: Mean effective radiation dose of CTC was 1.02 mSv. Of 101 polyps detected and removed by colonoscopy, 61 polyps were detected on supine and on prone CTC datasets on consensus unblinded review, resulting in 122 visible polyps (32 polyps <6 mm, 52 6–9.9 mm, and 38 ≥ 10 mm). Per-polyp sensitivity of CAD for all polyps was highest with MBIR (56/122, 45.9%), followed by ASIR80 (54/122, 44.3%) and FBP (43/122, 35.2%), with significant differences between FBP and IR algorithms (P < 0.017). Per-polyp sensitivity for polyps ≥ 10 mm was also higher with MBIR (25/38, 65.8%) and ASIR80 (24/38, 63.2%) than with FBP (20/38, 58.8%), albeit without statistical significance (P > 0.017). Mean number of FPs was significantly different among algorithms (FBP, 1.4; ASIR, 2.1; MBIR, 2.4) (P = 0.011). Conclusion: Although the performance of stand-alone CAD

  11. Multi-detector CT-colonography in inflammatory bowel disease: Prospective analysis of CT-findings to high-resolution video colonoscopy

    International Nuclear Information System (INIS)

    Andersen, Kjel; Vogt, Christoph; Blondin, Dirk; Beck, Andreas; Heinen, Wolfram; Aurich, Volker; Haeussinger, Dieter; Moedder, Ulrich; Cohnen, Mathias

    2006-01-01

    Aim: Prospective analysis of multi-detector CT-colonography (MDCTC) in patients with inflammatory bowel disease (IBD) compared to high-resolution video-endoscopy (HRVC). Materials and methods: Twenty-one patients (mean age 49.6 years) with Crohn's disease or ulcerative colitis underwent MDCTC (Somatom Volume Zoom, Siemens, Erlangen; 1 mm collimation, Pitch 8, 100 mAs, 120 kVp). HRVC was performed within 2 h after MDCTC. MDCTC was analyzed by two blinded readers. MDCTC-findings including bowel wall alterations and extraintestinal changes were compared to results of HRVC. Results: Over-all-sensitivity was 100% for endoluminal lesions with correct diagnosis of two cancers. Acute and chronic IBD were correctly identified by MDCTC in 63.6%, and 100%, respectively, with a specificity of 75%, and 100%. Sensitivity, specificity, positive and negative predictive values of MDCTC for diagnosis of acute and chronic disease were best for chronic disease. Sensitivity was worst for acute ulcerative colitis and specificity was worst for acute Crohn's disease. Haustral loss was seen only in ulcerative colitis. Pseudopolyps and fistulae were findings exclusive to Crohn's disease. Particularly extraintestinal findings as increased vascularization and local lymphadenopathy correlated well with endoscopic definition of acute disease. Because of the possibly more vulnerable colonic wall in acute inflammatory bowel disease, the air inflation for MDCTC should be performed most carefully to avoid any risk of colonic perforation. Conclusion: MDCTC may help to distinguish between patients with acute and chronic IBD. Especially extraintestinal complications, tumorous as well as pseudo-tumorous lesions can be detected with high sensitivity and specificity

  12. An interview study analysing patients' experiences and perceptions of non-laxative or full-laxative preparation with faecal tagging prior to CT colonography

    International Nuclear Information System (INIS)

    Ghanouni, A.; Smith, S.G.; Halligan, S.; Taylor, S.A.; Plumb, A.; Boone, D.; Wagner, C. von

    2013-01-01

    Aim: To compare patients' experiences of either non- or full-laxative bowel preparation with additional faecal tagging and subsequent computed tomographic (CT) colonography using in-depth interviews to elicit detailed responses. Materials and methods: Patients who received CT colonography after non- (n = 9) or full-laxative (n = 9) preparation participated in a semi-structured telephone interview at least 2 days after the investigation. Full-laxative preparation consisted of magnesium citrate and sodium picosulphate administered at home (or polyethylene glycol, if contraindicated), followed by hospital-based faecal tagging with iohexol. Non-laxative preparation was home-based barium sulphate for faecal tagging. Interviews were transcribed and thematically analysed to identify recurrent themes on patients' perceptions and experiences. Results: Experiences of full-laxative preparation were usually negative and characterized by pre-test diarrhoea that caused significant interference with daily routine. Post-test flatus was common. Non-laxative preparation was well-tolerated; patients reported no or minimal changes to bowel habit and rapid return to daily routine. Patients reported worry and uncertainty about the purpose of faecal tagging. For iohexol, this also added burden from waiting before testing. Conclusion: Patients' responses supported previous findings that non-laxative preparation is more acceptable than full-laxative preparation but both can be improved. Faecal tagging used in combination with laxative preparation is poorly understood, adding burden and worry. Home-based non-laxative preparation is also poorly understood and patients require better information on the purpose and mechanism in order to give fully informed consent. This may also optimize adherence to instructions. Allowing home-based self-administration of all types of preparation would prevent waiting before testing

  13. Adaptive statistical iterative reconstruction and Veo: assessment of image quality and diagnostic performance in CT colonography at various radiation doses.

    Science.gov (United States)

    Yoon, Min A; Kim, Se Hyung; Lee, Jeong Min; Woo, Hyoun Sik; Lee, Eun Sun; Ahn, Se Jin; Han, Joon Koo

    2012-01-01

    To evaluate the diagnostic performance of computed tomography (CT) colonography (CTC) reconstructed with different levels of adaptive statistical iterative reconstruction (ASiR, GE Healthcare) and Veo (model-based iterative reconstruction, GE Healthcare) at various tube currents in detection of polyps in porcine colon phantoms. Five porcine colon phantoms with 46 simulated polyps were scanned at different radiation doses (10, 30, and 50 mA s) and were reconstructed using filtered back projection (FBP), ASiR (20%, 40%, and 60%) and Veo. Eleven data sets for each phantom (10-mA s FBP, 10-mA s 20% ASiR, 10-mA s 40% ASiR, 10-mA s 60% ASiR, 10-mA s Veo, 30-mA s FBP, 30-mA s 20% ASiR, 30-mA s 40% ASiR, 30-mA s 60% ASiR, 30-mA s Veo, and 50-mA s FBP) yielded a total of 55 data sets. Polyp detection sensitivity and confidence level of 2 independent observers were evaluated with the McNemar test, the Fisher exact test, and receiver operating characteristic curve analysis. Comparative analyses of overall image quality score, measured image noise, and interpretation time were also performed. Per-polyp detection sensitivities and specificities were highest in 10-mA s Veo, 30-mA s FBP, 30-mA s 60% ASiR, and 50-mA s FBP (sensitivity, 100%; specificity, 100%). The area-under-the-curve values for the overall performance of each data set was also highest (1.000) at 50-mA s FBP, 30-mA s FBP, 30-mA s 60% ASiR, and 10-mA s Veo. Images reconstructed with ASiR showed statistically significant improvement in per-polyp detection sensitivity as the percent level of per-polyp sensitivity increased (10-mA s FBP vs 10-mA s 20% ASiR, P = 0.011; 10-mA s FBP vs 10-mA s 40% ASiR, P = 0.000; 10-mA s FBP vs 10-mA s 60% ASiR, P = 0.000; 10-mA s 20% ASiR vs 40% ASiR, P = 0.034). Overall image quality score was highest at 30-mA s Veo and 50-mA s FBP. The quantitative measurement of the image noise was lowest at 30-mA s Veo and second lowest at 10-mA s Veo. There was a trend of decrease in time

  14. CT Colonography (Virtual Colonoscopy)

    Science.gov (United States)

    ... so that the x-ray beam follows a spiral path. A special computer program processes this large ... computer generates a detailed three-dimensional (3-D) model of the colon, which the radiologist uses to ...

  15. Strategy for improving the detailed examination rate for colorectal cancer screening. New approach for detailed colorectal cancer examination. Study for optimal pre-treatment for CT colonography

    International Nuclear Information System (INIS)

    Mitsushima, Toru; Fujiwara, Masanori; Nagata, Koichi

    2012-01-01

    In order to drastically improve the detailed examination rate for strategic colorectal cancer examination in Japan, it is necessary to introduce CT colonography (CTC) as a detailed examination method for colorectal cancer examination, in addition to colonoscopy (CS) which is the conventional detailed examination method. In our study, a cleansing enema/contrast solution (3% Nif-C) was prepared by adding 60 ml of a water-soluble iodine-based contrast agent (Gastrografin) and water to an oral cleansing enema agent (Niflec) in solid (powder) form to a final amount of 2000 ml. The solution was compared with a Niflec solution. In terms of patient's acceptability, more than half of the examined patients answered ''easier to drink than the Niflec solution'' or ''as easy to drink as the Niflec solution. '' Also, the Nif-C solution was comparable or superior to the Niflec solution in terms of cleansing enema effects. Regarding imaging effects essential for CTC, the CT level was found to be 200 HU or greater for any large intestine region upon CTC using the Nif-C solution. Thus, practically sufficient imaging effects were achieved. In conclusion, CTC with pretreatment involving a cleansing enema with oral administration of 3% Nif-C is superior to CS in terms of patient's acceptability. In addition, at least in view of the overseas reports on CTC, there is no particular problem in terms of diagnostic accuracy. Thus, CTC is expected to resolve various problems related to colorectal cancer examination in Japan. (author)

  16. Evidence-based investigation of the influence of computer-aided detection of polyps on screening of colon cancer with CT colonography

    International Nuclear Information System (INIS)

    Yoshida, Hiroyuki

    2008-01-01

    Computed tomographic colonography (CTC), also known as virtual colonoscopy, is a CT examination of the colon for colorectal neoplasms. Recent large-scale clinical trials have demonstrated that CTC yields sensitivity comparable to optical colonoscopy in the detection of clinically significant polyps in a screening population, making CTC a promising technique for screening of colon cancer. For CTC to be a clinically practical means of screening, it must reliably and consistently detect polyps with high accuracy. However, high-level expertise is required to interpret the resulting CT images to find polyps, resulting in variable diagnostic accuracy among radiologists in the detection of polyps. A key technology to overcome this problem and to bring CTC to prime time for screening of colorectal cancer is computer-aided detection (CAD) of polyps. CAD automatically detects the locations of suspicious polyps in CTC images and presents them to radiologists. CAD has the potential to increase diagnostic performance in the detection of polyps as well as to reduce variability of the diagnostic accuracy among radiologists. This paper presents an evidence-based investigation of the influence of CAD on screening of colon cancer with CTC by describing the benefits of using CAD in the diagnosis of CTC, the fundamental CAD scheme for the detection of polyps in CTC, its detection performance, the effect on the improvement of detection performance, as well as the current and future challenges in CAD. (author)

  17. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si, Gyeonggi-do (Korea, Republic of); Seoul National University College of Medicine, Seoul National University Medical Research Center, Institute of Radiation Medicine, Bundang (Korea, Republic of); Kim, Kil Joong [Seoul National University College of Medicine, Department of Radiation Applied Life Science, Seoul (Korea, Republic of); Kim, Bohyoung; Lee, Hyunna [Seoul National University, School of Computer Science and Engineering, Seoul (Korea, Republic of); Park, Seong Ho [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Yanof, Jeffrey H. [Philips Healthcare, CT Clinical Science, Cleveland, OH (United States); Hwang, Seung-sik [Inha University School of Medicine, Department of Social and Preventive Medicine, Incheon (Korea, Republic of)

    2011-02-15

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI{sub vol}) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI{sub vol} and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI{sub vol} varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI{sub vol} and ATT (p = 0.61). ATT did not significantly affect CTDI{sub vol} (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI{sub vol} (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  18. Does the amount of tagged stool and fluid significantly affect the radiation exposure in low-dose CT colonography performed with an automatic exposure control?

    International Nuclear Information System (INIS)

    Lim, Hyun Kyong; Lee, Kyoung Ho; Kim, So Yeon; Kim, Young Hoon; Kim, Kil Joong; Kim, Bohyoung; Lee, Hyunna; Park, Seong Ho; Yanof, Jeffrey H.; Hwang, Seung-sik

    2011-01-01

    To determine whether the amount of tagged stool and fluid significantly affects the radiation exposure in low-dose screening CT colonography performed with an automatic tube-current modulation technique. The study included 311 patients. The tagging agent was barium (n = 271) or iodine (n = 40). Correlation was measured between mean volume CT dose index (CTDI vol ) and the estimated x-ray attenuation of the tagged stool and fluid (ATT). Multiple linear regression analyses were performed to determine the effect of ATT on CTDI vol and the effect of ATT on image noise while adjusting for other variables including abdominal circumference. CTDI vol varied from 0.88 to 2.54 mGy. There was no significant correlation between CTDI vol and ATT (p = 0.61). ATT did not significantly affect CTDI vol (p = 0.93), while abdominal circumference was the only factor significantly affecting CTDI vol (p < 0.001). Image noise ranged from 59.5 to 64.1 HU. The p value for the regression model explaining the noise was 0.38. The amount of stool and fluid tagging does not significantly affect radiation exposure. (orig.)

  19. Cost-Effectiveness of Computed Tomographic Colonography: A Prospective Comparison with Colonoscopy

    International Nuclear Information System (INIS)

    Arnesen, R.B.; Ginnerup-Pedersen, B.; Poulsen, P.B.; Benzon, K. von; Adamsen, S.; Laurberg, S.; Hart-Hansen, O.

    2007-01-01

    Purpose: To estimate the cost-effectiveness of detecting colorectal polyps with computed tomographic colonography (CTC) and subsequent polypectomy with primary colonoscopy (CC), using CC as the alternative strategy. Material and Methods: A marginal analysis was performed regarding 103 patients who had had CTC prior to same-day CC at two hospitals, H-I (n 53) and H-II (n = 50). The patients were randomly chosen from surveillance and symptomatic study populations (148 at H-I and 231 at H-II). Populations, organizations, and procedures were compared. Cost data on time consumption, medication, and minor equipment were collected prospectively, while data on salaries and major equipment were collected retrospectively. The effect was the (previously published) sensitivities of CTC and CC for detection of colorectal polyps ≥6 mm (H-I, n = 148) or ≥5 mm (H-II, n = 231). Results: Thirteen patients at each center had at least one colorectal polyp ≥6 mm or ≥5 mm. CTC was the cost-effective alternative at H-I (Euro 187 vs. Euro 211), while CC was the cost-effective alternative at H-II (Euro 239 vs. Euro 192). The cost-effectiveness (costs per finding) mainly depended on the sensitivity of CTC and CC, but the depreciation of equipment and the staff's use of time were highly influential as well. Conclusion: Detection of colorectal polyps ≥6 mm or ≥5 mm with CTC, followed by polypectomy by CC, can be performed cost-effectively at some institutions with the appropriate hardware and organization keywords

  20. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    International Nuclear Information System (INIS)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane; Halligan, Steve; Lilford, Richard J.; Morton, Dion; Dadswell, Edward; Atkin, Wendy

    2011-01-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  1. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Christian von; Smith, Samuel; Ghanouni, Alex; Power, Emily; Wardle, Jane [University College London, Department of Epidemiology and Public Health, London (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College Hospital, Centre for Medical Imaging, London (United Kingdom); Lilford, Richard J. [Birmingham University, Department of Epidemiology, Birmingham (United Kingdom); Morton, Dion [Birmingham University, Department of Surgery, Birmingham (United Kingdom); Dadswell, Edward; Atkin, Wendy [Imperial College London, Department of Surgery and Cancer, London (United Kingdom)

    2011-10-15

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE. (orig.)

  2. Non- or full-laxative CT colonography vs. endoscopic tests for colorectal cancer screening: A randomised survey comparing public perceptions and intentions to undergo testing

    Energy Technology Data Exchange (ETDEWEB)

    Ghanouni, Alex; Wardle, Jane; Von Wagner, Christian [University College London, Health Behaviour Research Centre, Department of Epidemiology and Public Health, London (United Kingdom); Halligan, Steve; Plumb, Andrew; Boone, Darren [University College London, Centre for Medical Imaging, London (United Kingdom)

    2014-07-15

    Compare public perceptions and intentions to undergo colorectal cancer screening tests following detailed information regarding CT colonography (CTC; after non-laxative preparation or full-laxative preparation), optical colonoscopy (OC) or flexible sigmoidoscopy (FS). A total of 3,100 invitees approaching screening age (45-54 years) were randomly allocated to receive detailed information on a single test and asked to return a questionnaire. Outcomes included perceptions of preparation and test tolerability, health benefits, sensitivity and specificity, and intention to undergo the test. Six hundred three invitees responded with valid questionnaire data. Non-laxative preparation was rated more positively than enema or full-laxative preparations [effect size (r) = 0.13 to 0.54; p < 0.0005 to 0.036]; both forms of CTC and FS were rated more positively than OC in terms of test experience (r = 0.26 to 0.28; all p-values < 0.0005). Perceptions of health benefits, sensitivity and specificity (p = 0.250 to 0.901), and intention to undergo the test (p = 0.213) did not differ between tests (n = 144-155 for each test). Despite non-laxative CTC being rated more favourably, this study did not find evidence that offering it would lead to substantially higher uptake than full-laxative CTC or other methods. However, this study was limited by a lower than anticipated response rate. (orig.)

  3. Patient acceptability of CT colonography compared with double contrast barium enema: results from a multicentre randomised controlled trial of symptomatic patients.

    Science.gov (United States)

    von Wagner, Christian; Smith, Samuel; Halligan, Steve; Ghanouni, Alex; Power, Emily; Lilford, Richard J; Morton, Dion; Dadswell, Edward; Atkin, Wendy; Wardle, Jane

    2011-10-01

    To determine patient acceptability of barium enema (BE) or CT colonography (CTC). After ethical approval, 921 consenting patients with symptoms suggestive of colorectal cancer who had been randomly assigned and completed either BE (N = 606) or CTC (N = 315) received a questionnaire to assess experience of the clinical episode including bowel preparation, procedure and complications. Satisfaction, worry and physical discomfort were assessed using an adapted version of a validated acceptability scale. Non-parametric methods assessed differences between the randomised tests and the effect of patient characteristics. Patients undergoing BE were significantly less satisfied (median 61, interquartile range [IQR] 54-67 vs. median 64, IQR 56-69; p = 0.003) and experienced more physical discomfort (median 40, IQR 29-52 vs. median 35.5, IQR 25-47; p < 0.001) than those undergoing CTC. Post-test, BE patients were significantly more likely to experience 'abdominal pain/cramps' (68% vs. 57%; p = 0.007), 'soreness' (57% vs. 37%; p < 0.001), 'nausea/vomiting' (16% vs. 8%; p = 0.009), 'soiling' (31% vs. 23%; p = 0.034) and 'wind' (92% vs. 84%; p = 0.001) and in the case of 'wind' to also rate it as severe (27% vs. 15%; p < 0.001). CTC is associated with significant improvements in patient experience. These data support the case for CTC to replace BE.

  4. Sensitivity and specificity of CT colonography for the detection of colonic neoplasia after positive faecal occult blood testing: systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Plumb, Andrew A.; Pendse, Douglas A.; Taylor, Stuart A. [University College London, Centre for Medical Imaging, London (United Kingdom); Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College London, University College Hospital, Centre for Medical Imaging, Podium Level 2, London (United Kingdom); Mallett, Susan [University of Oxford, Department of Primary Care Health Sciences, Oxford (United Kingdom)

    2014-05-15

    CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. (orig.)

  5. Sensitivity and specificity of CT colonography for the detection of colonic neoplasia after positive faecal occult blood testing: systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Plumb, Andrew A.; Pendse, Douglas A.; Taylor, Stuart A.; Halligan, Steve; Mallett, Susan

    2014-01-01

    CT colonography (CTC) is recommended after positive faecal occult blood testing (FOBt) when colonoscopy is incomplete or infeasible. We aimed to estimate the sensitivity and specificity of CTC for colorectal cancer and adenomatous polyps following positive FOBt via systematic review. The MEDLINE, EMBASE, AMED and Cochrane Library databases were searched for CTC studies reporting sensitivity and specificity for colorectal cancer and adenomatous polyps. Included subjects had tested FOBt-positive by guaiac or immunochemical methods. Per-patient detection rates were summarized via forest plots. Meta-analysis of sensitivity and specificity was conducted using a bivariate random effects model and the average operating point calculated. Of 538 articles considered, 5 met inclusion criteria, describing results from 622 patients. Research study quality was good. CTC had a high per-patient average sensitivity of 88.8 % (95 % CI 83.6 to 92.5 %) for ≥6 mm adenomas or colorectal cancer, with low between-study heterogeneity. Specificity was both more heterogeneous and lower, at an average of 75.4 % (95 % CI 58.6 to 86.8 %). Few studies have investigated CTC in FOBt-positive individuals. CTC is sensitive at a ≥6 mm threshold but specificity is lower and variable. Despite the limited data, these results suggest that CTC may adequately substitute for colonoscopy when the latter is undesirable. (orig.)

  6. Evaluating patients' preferences for type of bowel preparation prior to screening CT colonography: Convenience and comfort versus sensitivity and specificity

    International Nuclear Information System (INIS)

    Ghanouni, A.; Halligan, S.; Taylor, S.A.; Boone, D.; Plumb, A.; Wardle, J.; Wagner, C. von

    2013-01-01

    Aims: To explore the relative value patients place on comfort and convenience versus test sensitivity and specificity in the context of computed tomographic colonography (CTC) screening. Materials and methods: Twenty semi-structured interviews were carried out with patients attending hospital for radiological tests unrelated to CTC. Preferences for CTC with different types of bowel preparation for CTC screening were examined and interviews were analysed thematically. The discussion guide included separate sections on CTC, bowel preparation methods (non-, reduced- and full-laxative), and sensitivity and specificity. Patients were given information on each topic in turn and asked about their views and preferences during each section. Results: Following information about the test, patients' attitudes towards CTC were positive. Following information on bowel preparation, full-laxative purgation was anticipated to cause more adverse physical and lifestyle effects than using reduced- or non-laxative preparation. However, stated preferences were approximately equally divided, largely due to patients anticipating that non-laxative preparations would reduce test accuracy (because the bowel was not thoroughly cleansed). Following information on sensitivity and specificity (which supported patients' expectations), the predominant stated preference was for full-laxative preparation. Conclusions: Patients are likely to value test sensitivity and specificity over a more comfortable and convenient preparation. Future research should test this hypothesis on a larger sample

  7. Adverse events during CT colonography for screening, diagnosis and preoperative staging of colorectal cancer: a Japanese national survey

    International Nuclear Information System (INIS)

    Nagata, Koichi; Takabayashi, Ken; Yasuda, Takaaki; Hirayama, Michiaki; Endo, Shungo; Nozaki, Ryoichi; Shimada, Takenobu; Kanazawa, Hidenori; Fujiwara, Masanori; Shimizu, Norihito; Iwatsuki, Tatema; Iwano, Teruaki; Saito, Hiroshi

    2017-01-01

    To retrospectively evaluate the frequencies and magnitudes of adverse events associated with computed tomographic colonography (CTC) for screening, diagnosis and preoperative staging of colorectal cancer. A Japanese national survey on CTC was administered by use of an online survey tool in the form of a questionnaire. The questions covered mortality, colorectal perforation, vasovagal reaction, total number of examinations, and examination procedures. The survey data was collated and raw frequencies were determined. Fisher's exact test was used to determine differences in event rates between groups. At 431 institutions, 147,439 CTC examinations were performed. No deaths were reported. Colorectal perforations occurred in 0.014% (21/147,439): 0.003% (1/29,823) in screening, 0.014% (13/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The perforation risk was significantly lower in screening than in preoperative staging CTC procedures (p = 0.028). Eighty-one per cent of perforation cases (17/21) did not require emergency surgery. Vasovagal reaction occurred in 0.081% (120/147,439): 0.111% (33/29,823) in screening, 0.088% (80/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The risk of colorectal perforation and vasovagal reaction in CTC is low. The frequency of colorectal perforation associated with CTC is least in the screening group and greatest in the preoperative-staging group. (orig.)

  8. Adverse events during CT colonography for screening, diagnosis and preoperative staging of colorectal cancer: a Japanese national survey

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Koichi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Takabayashi, Ken [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Hokkaido Gastroenterology Hospital, Department of Radiology, Sapporo (Japan); Yasuda, Takaaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Nagasaki Kamigoto Hospital, Department of Radiology, Nagasaki (Japan); Hirayama, Michiaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Tonan Hospital, Department of Gastroenterology, Sapporo (Japan); Endo, Shungo [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Fukushima Medical University, Department of Coloproctology, Aizu Medical Centre, Aizu-Wakamatsu, Fukushima (Japan); Nozaki, Ryoichi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Takano Hospital, Coloproctology Centre, Kumamoto (Japan); Shimada, Takenobu [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); Cancer Detection Centre of the Miyagi Cancer Society, Sendai, Miyagi (Japan); Kanazawa, Hidenori [National Cancer Centre, Division of Screening Technology, Centre for Public Health Sciences, Tokyo (Japan); Jichi Medical University, Department of Radiology, Shimotsuke, Tochigi (Japan); Fujiwara, Masanori [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Kameda Medical Centre Makuhari, Radiology Section, Mihama-ku, Chiba (Japan); Shimizu, Norihito [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Matsuoka Clinic, Radiology Section, Nara (Japan); Iwatsuki, Tatema [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Matsuda Hospital, Radiology Section, Hamamatsu, Shizuoka (Japan); Iwano, Teruaki [Gastrointestinal Advanced Imaging Academy, Tochigi (Japan); Tokushima Kensei Hospital, Radiology Section, Tokushima (Japan); Saito, Hiroshi [Japanese Society of Gastrointestinal Cancer Screening, Committee for Quality Assessment of Colorectal Cancer Screening, Tokyo (Japan); National Cancer Centre, Division of Screening Assessment and Management, Centre for Public Health Sciences, Tokyo (Japan)

    2017-12-15

    To retrospectively evaluate the frequencies and magnitudes of adverse events associated with computed tomographic colonography (CTC) for screening, diagnosis and preoperative staging of colorectal cancer. A Japanese national survey on CTC was administered by use of an online survey tool in the form of a questionnaire. The questions covered mortality, colorectal perforation, vasovagal reaction, total number of examinations, and examination procedures. The survey data was collated and raw frequencies were determined. Fisher's exact test was used to determine differences in event rates between groups. At 431 institutions, 147,439 CTC examinations were performed. No deaths were reported. Colorectal perforations occurred in 0.014% (21/147,439): 0.003% (1/29,823) in screening, 0.014% (13/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The perforation risk was significantly lower in screening than in preoperative staging CTC procedures (p = 0.028). Eighty-one per cent of perforation cases (17/21) did not require emergency surgery. Vasovagal reaction occurred in 0.081% (120/147,439): 0.111% (33/29,823) in screening, 0.088% (80/91,007) in diagnosis and 0.028% (7/25,330) in preoperative staging. The risk of colorectal perforation and vasovagal reaction in CTC is low. The frequency of colorectal perforation associated with CTC is least in the screening group and greatest in the preoperative-staging group. (orig.)

  9. CT colonography versus colonoscopy in the follow-up of patients after diverticulitis - A prospective, comparative study

    International Nuclear Information System (INIS)

    Hjern, F.; Jonas, E.; Holmstroem, B.; Josephson, T.; Mellgren, A.; Johansson, C.

    2007-01-01

    Aim: To assess whether computed tomography colonography (CTC) is a viable alternative to colonoscopy or double contrast barium enema in the follow-up of patients after diverticulitis. Material and methods: Fifty patients underwent CTC followed immediately by colonoscopy. Results were blinded to the examiners. Findings of diverticular disease and patient acceptance were evaluated. Results: Bowel preparation and distension were good in the majority of CTC and colonoscopy examinations. Diverticular disease was found in 96% of patients at CTC and in 90% at colonoscopy. The rate of agreement between CTC and colonoscopy for diverticular findings in the sigmoid colon was good (κ = 0.64). No complications were seen. Patients found colonoscopy more uncomfortable (p < 0.03), more painful (p < 0.001), and more difficult (p < 0.01) than CTC. Of the patients favouring one examination, 74% preferred CTC. Conclusion: CTC appears to have a better diagnostic potential for imaging of diverticular disease-specific findings, when compared with colonoscopy. Also, CTC was less uncomfortable and was preferred by a majority of patients. CTC seems to be a reasonable alternative in follow-up of patients with symptomatic diverticular disease

  10. Automated image-based colon cleansing for laxative-free CT colonography computer-aided polyp detection

    International Nuclear Information System (INIS)

    Linguraru, Marius George; Panjwani, Neil; Fletcher, Joel G.; Summer, Ronald M.

    2011-01-01

    Purpose: To evaluate the performance of a computer-aided detection (CAD) system for detecting colonic polyps at noncathartic computed tomography colonography (CTC) in conjunction with an automated image-based colon cleansing algorithm. Methods: An automated colon cleansing algorithm was designed to detect and subtract tagged-stool, accounting for heterogeneity and poor tagging, to be used in conjunction with a colon CAD system. The method is locally adaptive and combines intensity, shape, and texture analysis with probabilistic optimization. CTC data from cathartic-free bowel preparation were acquired for testing and training the parameters. Patients underwent various colonic preparations with barium or Gastroview in divided doses over 48 h before scanning. No laxatives were administered and no dietary modifications were required. Cases were selected from a polyp-enriched cohort and included scans in which at least 90% of the solid stool was visually estimated to be tagged and each colonic segment was distended in either the prone or supine view. The CAD system was run comparatively with and without the stool subtraction algorithm. Results: The dataset comprised 38 CTC scans from prone and/or supine scans of 19 patients containing 44 polyps larger than 10 mm (22 unique polyps, if matched between prone and supine scans). The results are robust on fine details around folds, thin-stool linings on the colonic wall, near polyps and in large fluid/stool pools. The sensitivity of the CAD system is 70.5% per polyp at a rate of 5.75 false positives/scan without using the stool subtraction module. This detection improved significantly (p = 0.009) after automated colon cleansing on cathartic-free data to 86.4% true positive rate at 5.75 false positives/scan. Conclusions: An automated image-based colon cleansing algorithm designed to overcome the challenges of the noncathartic colon significantly improves the sensitivity of colon CAD by approximately 15%.

  11. Double Colorectal Cancer Only Diagnosed by Computed Tomographic Colonography

    Directory of Open Access Journals (Sweden)

    Koichi Nagata

    2008-02-01

    Full Text Available A 58-year-old woman presented to her physician with rectal bleeding and intermittent diarrhea. Optical colonoscopy revealed a bulky tumor which was diagnosed as rectal cancer. She was referred to our institution for further evaluation and treatment. Slim optical colonoscopy showed an obstructive cancer in the rectosigmoid junction and no information of the proximal side of the obstruction. The patient then underwent computed tomographic (CT colonography for further evaluation of the proximal side. Three-dimensional endoluminal ‘fly-through’ images revealed another protruded lesion in the proximal side of the obstruction. Diagnosis of synchronous double cancer was made by CT colonography. This CT data was not only used to create three-dimensional images but also to decide on a preoperative clinical staging. Laparoscopy-assisted high anterior resection was performed and T3 rectal cancer and T1 sigmoid colon cancer were confirmed in the resected specimen. Follow-up optical colonoscopy revealed no other tumors. CT colonography has recently become a popular preoperative examination tool with significant improvement in quality of image due to a rapid progress in computer technology. CT colonography correctly showed synchronous double cancer in our case and provided crucial information for planning surgery. We recommend that CT colonography should be used for evaluating the proximal side of obstructive colorectal cancer.

  12. Effectiveness and efficiency of CT-colonography compared to conventional colonoscopy for the early detection and diagnosis of colorectal cancer

    Directory of Open Access Journals (Sweden)

    Hiebinger, Cora

    2009-02-01

    Full Text Available Health political background: Colorectal cancer (CC is the second most common cancer and cause of cancer death for both men and women in Germany. Various methods for early detection of CC exist, including conventional coloscopy which is reimbursed within the scope of cancer screening, as well as computertomography-coloscopy (CTC which is currently not reimbursed. Scientific background: CTC is a mere diagnostic procedure which has a lower risk of perforation than conventional coloscopy. However, as it is an x-ray procedure, it exposes the patient to radiation. Conventional coloscopy is considered the gold standard due to its high sensitivity and specificity for locating adenomas. Furthermore, it offers the advantage that in addition to extended diagnostic measures therapeutic measures can be undertaken during the procedure. Research questions: This HTA-report aims to evaluate the effectiveness and efficiency of CTC in comparison to conventional coloscopy in the early detection and diagnosis of colorectal cancer and/or its precursors and which ethical and legal aspects have to be considered. Methods: The systematic literature search (27 international literature data bases yielded a total of 1,713 abstracts. After a two-step selection process 36 publications remained to be assessed. Results: The results regarding the effectivity of CTC in diagnosis and screening for colorectal cancer and/or its precursors are partly promising, however, they are very heterogeneous. Therefore, regarding its sensitivity and specificity, CTC cannot be considered an equivalent alternative to conventional coloscopy for diagnosis and screening. The heterogeneity of results is due to technical (device type, settings, patient dependent (preparation and operator dependent (training factors. No economic results for a comparison of the procedures for diagnosis exist. Regarding the cost-effectiveness of a CTC-screening, international model calculations are available. According

  13. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Spotlight Recently posted: How ...

  14. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... for the exam to be performed with the most accuracy. If you have any questions about the ... go back to work the same day in most cases. Perhaps you might have some concerns about ...

  15. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... of Use | Links | Site Map Copyright © 2018 Radiological Society of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying but encourage linking ...

  16. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available ... Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI Story Radiology and You Take our ... Obtain and Share Your Medical Images Movement Disorders Video: The Basketball Game: An MRI Story Radiology and You Take our ...

  17. Your Radiologist Explains CT Colonography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... virtual colonoscopy. Virtual colonoscopy is a diagnostic imaging test that is used to screen the large intestine ...

  18. Health economic aspects of evaluation with diffusion weighted MR and MR colonography compared to standard evaluation with colonoscopy and CT before rectal cancer surgery

    DEFF Research Database (Denmark)

    Achiam, Michael P; Kjellberg, Jakob; Rosenberg, Jacob

    2017-01-01

    calculation and a practical cost calculation. The cost drivers utilized are an average cost based on the cost of all procedures and diagnostic modalities performed in hospitalized patients (DRG) and outpatients (DAGS [Danish outpatient grouping system]) in Denmark. Results The total cost for a full colorectal......) colonography and diffusion-weighted MR of the liver. Purpose To compare the economic aspects of this modality with the standard evaluation in an analysis of the different cost drivers. Material and Methods Based on the results from previous studies, two calculations were performed, a theoretical cost...... the two preoperative diagnostic modalities per patient were €312 and €712, respectively. Conclusion This cost analysis shows the cost effectiveness of the new modality as the future standard preoperative diagnostic work-up by reducing total cost and by having a higher sensitivity and completion rate....

  19. Audit of the introduction of CT colonography for detection of colorectal carcinoma in a non-academic environment and its implications for the national bowel cancer screening programme

    International Nuclear Information System (INIS)

    Thomas, S.; Atchley, J.; Higginson, A.

    2009-01-01

    Aim: To compare the sensitivity of double-contrast barium enema (DCBE) with computed tomography colonography (CTC) to determine whether CTC is superior for the detection of colorectal cancer (CRC) locally, and to compare the results to those of a national barium enema audit. Materials and methods: All patients undergoing diagnostic DCBE or CTC between January 2003 and December 2005 were identified from the picture archiving communication system (PACS). Patients with a confirmed diagnosis of CRC were identified from the local cancer registry. Patients who were not diagnosed as having CRC on imaging were assumed true negatives if they were not listed in the cancer registry by December 2007, giving a minimum of 2 years follow-up. DCBE and CTC reports of all patients with CRC were analysed, and cancer detection was considered to have occurred (positive test result) if the report stated the definite presence of CRC or possible CRC requiring further investigation. Results: 2520 DCBEs and 604 CTCs were included. Twenty-one of 33 patients with CRC were detected using DCBE (incidence 1.31%, sensitivity 63.7%). Thirty-two of 33 patients with CRC were -detected using CTC (incidence 5.46%, sensitivity 97.7%). Conclusion: CTC is more sensitive for the detection of CRC, and its introduction in a district general hospital is justified. However, there has been a consequent decline in DCBE sensitivity, which, if reflected nationally, suggests CTC is the preferential screening test for CRC

  20. Audit of the introduction of CT colonography for detection of colorectal carcinoma in a non-academic environment and its implications for the national bowel cancer screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S. [Department of Radiology, Queen Alexandra Hospital, Southwick Hill Road, Cosham, Portsmouth PO3 6AD (United Kingdom)], E-mail: Susan.Thomas@porthosp.nhs.uk; Atchley, J.; Higginson, A. [Department of Radiology, Queen Alexandra Hospital, Southwick Hill Road, Cosham, Portsmouth PO3 6AD (United Kingdom)

    2009-02-15

    Aim: To compare the sensitivity of double-contrast barium enema (DCBE) with computed tomography colonography (CTC) to determine whether CTC is superior for the detection of colorectal cancer (CRC) locally, and to compare the results to those of a national barium enema audit. Materials and methods: All patients undergoing diagnostic DCBE or CTC between January 2003 and December 2005 were identified from the picture archiving communication system (PACS). Patients with a confirmed diagnosis of CRC were identified from the local cancer registry. Patients who were not diagnosed as having CRC on imaging were assumed true negatives if they were not listed in the cancer registry by December 2007, giving a minimum of 2 years follow-up. DCBE and CTC reports of all patients with CRC were analysed, and cancer detection was considered to have occurred (positive test result) if the report stated the definite presence of CRC or possible CRC requiring further investigation. Results: 2520 DCBEs and 604 CTCs were included. Twenty-one of 33 patients with CRC were detected using DCBE (incidence 1.31%, sensitivity 63.7%). Thirty-two of 33 patients with CRC were -detected using CTC (incidence 5.46%, sensitivity 97.7%). Conclusion: CTC is more sensitive for the detection of CRC, and its introduction in a district general hospital is justified. However, there has been a consequent decline in DCBE sensitivity, which, if reflected nationally, suggests CTC is the preferential screening test for CRC.

  1. Time-efficient CT colonography interpretation using an advanced image-gallery-based, computer-aided ''first-reader'' workflow for the detection of colorectal adenomas

    International Nuclear Information System (INIS)

    Mang, Thomas; Ringl, Helmut; Weber, Michael; Mueller-Mang, Christina; Hermosillo, Gerardo; Wolf, Matthias; Bogoni, Luca; Salganicoff, Marcos; Raykar, Vikas; Graser, Anno

    2012-01-01

    To assess the performance of an advanced ''first-reader'' workflow for computer-aided detection (CAD) of colorectal adenomas ≥ 6 mm at computed tomographic colonography (CTC) in a low-prevalence cohort. A total of 616 colonoscopy-validated CTC patient-datasets were retrospectively reviewed by a radiologist using a ''first-reader'' CAD workflow. CAD detections were presented as galleries of six automatically generated two-dimensional (2D) and three-dimensional (3D) images together with interactive 3D target views and 2D multiplanar views of the complete dataset. Each patient-dataset was interpreted by initially using CAD image-galleries followed by a fast 2D review to address unprompted colonic areas. Per-patient, per-polyp, and per-adenoma sensitivities were calculated for lesions ≥ 6 mm. Statistical testing employed Fisher's exact and McNemar tests. In 91/616 patients, 131 polyps (92 adenomas, 39 non-adenomas) ≥ 6 mm and two cancers were identified by reference standard. Using the CAD gallery-based first-reader workflow, the radiologist detected all adenomas ≥ 10 mm (34/34) and cancers. Per-patient and polyp sensitivities for lesions ≥ 6 mm were 84.3 % (75/89), and 83.2 % (109/131), respectively, with 89.1 % (57/64) and 85.9 % (79/92) for adenomas. Overall specificity was 95.6 % (504/527). Mean interpretation time was 3.1 min per patient. A CAD algorithm, applied in an image-gallery-based first-reader workflow, can substantially decrease reading times while enabling accurate detection of colorectal adenomas in a low-prevalence population. (orig.)

  2. Contrast-enhanced computed tomographic colonography in the follow-up of colorectal cancer patients: a feasibility study

    International Nuclear Information System (INIS)

    Laghi, Andrea; Iannaccone, Riccardo; Carbone, Iacopo; Piacentini, Francesca; Passariello, Roberto; Bria, Emilio; Trasatti, Luciana; Lauro, Salvatore; Vecchione, Aldo

    2003-01-01

    The aim of our study was to assess whether contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up program of colorectal cancer patients. Thirty-five patients, surgically treated for colorectal cancer, underwent a follow-up program that included physical examination, carcinoembryonic antigen serum assay, conventional colonoscopy, liver ultrasonography, and chest X-ray. For these patients, we added a yearly contrast-enhanced CT colonography. All CT examinations were performed with a high-resolution protocol using a multidetector spiral CT scanner (Siemens, Erlangen, Germany) prior to and after the administration of 130 ml of i.v. contrast material. Images were directly analyzed on a dedicated workstation by two radiologists to determine colonic evaluation, visualization of colonic anastomosis, presence of polyps, and extra-colonic findings. Colonic evaluation was judged as optimal in 91.7% of all colonic segments. All mechanical surgical anastomoses were visualized with CT colonography. There was no evidence of anastomotic recurrence. Seven polyps were detected in five different patients with CT colonography, with two false-positive and no false-negative examinations. Three liver metastases and two basal pulmonary nodules were also identified. Contrast-enhanced CT colonography is a feasible alternative to both conventional colonoscopy and liver ultrasonography in the follow-up of patients operated on for colorectal cancer. (orig.)

  3. Test-positive rate at CT colonography is increased by rectal bleeding and/or unexplained weight loss, unlike other common gastrointestinal symptoms

    International Nuclear Information System (INIS)

    Hock, D.; Materne, R.; Ouhadi, R.; Mancini, I.; Aouachria, S.A.; Nchimi, A.

    2015-01-01

    We evaluated the rate of significant colonic and extra-colonic abnormalities at computed tomography colonography (CTC), according to symptoms and age. We retrospectively evaluated 7361 consecutive average-risk subjects (3073 males, average age: 60.3 ± 13.9; range 18–96 years) for colorectal cancer (CRC) who underwent CTC. They were divided into three groups according to clinical symptoms: 1343 asymptomatic individuals (group A), 899 patients with at least one “alarm” symptom for CRC, including rectal bleeding and unexplained weight loss (group C), and 5119 subjects with other gastrointestinal symptoms (group B). Diagnostic and test-positive rates of CTC were established using optical colonoscopy (OC) and/or surgery as reference standard. In addition, clinically significant extra-colonic findings were noted. 903 out of 7361 (12%, 95% confidence interval (CI) 0.11–0.13) subjects had at least one clinically significant colonic finding at CTC. CTC true positive fraction and false positive fraction were respectively 637/642 (99.2%, 95%CI 0.98–0.99) and 55/692 (7.95%, 95%CI 0.05–0.09). The pooled test-positive rate in group C (138/689, 20.0%, 95%CI 0.17–0.23) was significantly higher than in both groups A (79/1343, 5.9%, 95%CI 0.04–0.07) and B (420/5329, 7.5%, 95%CI 0.07–0.08) (p < 0.001). Aging and male gender were associated to a higher test positive rate. The rate of clinically significant extra-colonic findings was significantly higher in group C (44/689, 6.4%, 95%CI 0.04–0.08) versus groups A (26/1343, 1.9%, 95%CI 0.01–0.02) and B (64/5329, 1.2%, 95%CI 0.01–0.02) (p < 0.001). Both test-positive and significant extra-colonic finding rates at CTC are significantly increased in the presence of “alarm” gastrointestinal symptoms especially in older patients

  4. Absorbed dose in CT. Comparison by CT dose index

    International Nuclear Information System (INIS)

    Yamamoto, Kenji; Akazawa, Hiroshi; Andou, Takashi

    2002-01-01

    Few reports have discussed the absorbed dose on CT units with increased scanning capacity even with the current widespread adoption of multi-slice CT units. To compare and investigate the dose indexes among CT units, we measured the absorbed dose on CT units operating in Nagano Prefecture Japan. The measurements showed proportionality between phantom absorbed dose and the exposured mAs values in conventional scanning operation. Further, the measurements showed that the absorbed dose in the center of the phantom differed by about 2.1-fold between the highest and lowest levels on individual CT units. Within a single company, multi-slice CT units of the same company gave absorbed doses of about 1.3 to 1.5 times those of conventional single-slice CT units under the same exposured conditions of conventional scanning. When the scanning pitch was reduced in helical scanning, the absorbed dose at the center of the phantom increased. (author)

  5. CT in neuromuscular disorders: A comparison of CT and histology

    International Nuclear Information System (INIS)

    Vliet, A.M. van der; Thijssen, H.O.M.; Merx, J.L.; Joosten, E.

    1988-01-01

    The value of CT-examination of the muscles compared to histology was studied in a retrospective analysis of 30 patients with clinical suspicion of neuromuscular disorder. In the evaluation of the CT-results descriptive criteria were used. The histologic diagnosis came from needle-biopsies taken from the quadriceps muscle. Considering the whole group of neuromuscular disorders, CT has an overall accuracy of 84.8%, a positive predictive value of 95.5% and a negative predictive value of 63.6%. This makes the use of CT as a diagnostic tool in neuromuscular disorders a reliable examination technique. In patients with a polymyositis there is even a 100% correlation between CT findings and biopsy results. Discrepancy between the biopsy results is remarkable of the quadriceps muscle and the CT findings: The number of abnormal histological findings is twice the number of abnormal CT findings. Using the more proximal gluteal region as a biopsy site would have decreased this discrepancy and would therefore have given a better correlation between CT and histology. The choice of protocol in determining the levels to be scanned is of great importance in achieving good reproducability in follow-up CT examinations. (orig.)

  6. CT portography by multidetector helical CT. Comparison of three rendering models

    International Nuclear Information System (INIS)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki

    2002-01-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  7. CT portography by multidetector helical CT. Comparison of three rendering models

    Energy Technology Data Exchange (ETDEWEB)

    Nakayama, Yoshiharu; Imuta, Masanori; Funama, Yoshinori; Kadota, Masataka; Utsunomiya, Daisuke; Shiraishi, Shinya; Hayashida, Yoshiko; Yamashita, Yasuyuki [Kumamoto Univ. (Japan). School of Medicine

    2002-12-01

    The purpose of this study was to assess the value of multidetector CT portography in visualizing varices and portosystemic collaterals in comparison with conventional portography, and to compare the visualizations obtained by three rendering models (volume rendering, VR; minimum intensity projection, MIP; and shaded surface display, SSD). A total of 46 patients with portal hypertension were examined by CT and conventional portography for evaluation of portosystemic collaterals. CT portography was performed by multidetector CT (MD-CT) scanner with a slice thickness of 2.5 mm and table feed of 7.5 mm. Three types of CT portographic models were generated and compared with transarterial portography. Among 46 patients, 48 collaterals were identified on CT transverse images, while 38 collaterals were detected on transarterial portography. Forty-four of 48 collaterals identified on CT transverse images were visualized with the MIP model, while 34 and 29 collaterals were visualized by the VR and SSD methods, respectively. The average CT value for the portal vein and varices was 198 HU with data acquisition of 50 sec after contrast material injection. CT portography by multidetector CT provides excellent images in the visualization of portosystemic collaterals. The images of collaterals produced by MD-CT are superior to those of transarterial portography. Among the three rendering techniques, MIP provides the best visualization of portosystemic collaterals. (author)

  8. Dark-lumen MR colonography with fecal tagging: a comparison of water enema and air methods of colonic distension for detecting colonic neoplasms

    International Nuclear Information System (INIS)

    Rodriguez Gomez, Sonia; Pages Llinas, Mario; Juan Garcia, Carmen de; Rimola Gibert, Jordi; Ayuso Colella, Juan R.; Ayuso Colella, Carmen; Castells Garangou, Antoni; Bordas Alsina, Josep M.

    2008-01-01

    The purpose was to evaluate MR colonography (MRC) with barium fecal tagging in detecting colorectal pathology and to determine how air-based and water-based colonic distension influences MRC. We studied 83 patients with high risk of colonic neoplasms. All received oral barium sulfate for colonic preparation before unenhanced and enhanced T1-weighted gradient-echo MRC using either water (n=54) or air (n=29) for colonic distension. Fecal tagging, distension, and artifacts were recorded. All patients underwent conventional colonoscopy within 2 weeks of MRC; the techniques were compared for detection of malignant neoplasms and polyps ≥1 cm, 6-9 mm, and ≤5 mm. Fecal tagging was ''good'' in 76% of the colonic segments in water-distended patients and 46% of air-distended patients. The degree of distension was ''good'' in 90.7% of water-distended patients and 44% of air-distended patients. Severe artifacts were present in 15% air-distended patients and 0.3% of water-distended patients. Both water-distended and air-distended MRC detected all malignant neoplasms and polyps ≥1 cm, but more air-distended MRC were excluded for poor quality. MRC with fecal tagging is useful for detecting lesions ≥1 cm. Air distension was inferior to water distension in most aspects. Water-based colonic distension should be used for barium-tagging MRC. (orig.)

  9. Multidetector CT of the colon

    International Nuclear Information System (INIS)

    Luboldt, W.; Hoepffner, N.; Holzer, K.

    2003-01-01

    Multidetector technology, enabling faster imaging, higher spatial resolution and reduction in radiation dose, increases the role of CT in colonic diagnostic. The higher spatial resolution in the z-direction also changes the way to analyze the images. Instead of reading axial sections, now the colon can be systematically assessed in 3D by scrolling through multiplanar reconstructions or in CT colonography by virtual endoscopy. With ongoing improvements in computer-aided diagnosis CT colonography becomes an alternative to fiberoptic colonocopy for screening (http://www.multiorganscreening.org). In this article we propose a CT examination protocol for the colon, describe the typical imaging findings of different colonic diseases, and summarize the current status of CT colonography. (orig.)

  10. CT Colonography - competition or complementary?: guest editorial ...

    African Journals Online (AJOL)

    South African Gastroenterology Review. Journal Home · ABOUT · Advanced Search · Current Issue · Archives · Journal Home > Vol 2, No 2 (2004) >. Log in or Register to get access to full text downloads.

  11. CT Colonography - competition or complementary?: guest editorial ...

    African Journals Online (AJOL)

    South African Gastroenterology Review. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 2, No 2 (2004) >. Log in or Register to get access to full text downloads.

  12. Comparison of CT numbers between cone-beam CT and multi-detector CT

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung

    2010-01-01

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, ρ(g/cm 3 ), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were ρ=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, ρ=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, ρ=0.001 H+1.43 with R2 value of 0.980 for i-CAT and ρ=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  13. Comparison of CT numbers between cone-beam CT and multi-detector CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Soo; Han, Won Jeong; Kim, Eun Kyung [Department of Oral and Maxillofacial Radiology, School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2010-06-15

    To compare the CT numbers on 3 cone-beam CT (CBCT) images with those on multi-detector CT (MDCT) image using CT phantom and to develop linear regressive equations using CT numbers to material density for all the CT scanner each. Mini CT phantom comprised of five 1 inch thick cylindrical models with 1.125 inches diameter of materials with different densities (polyethylene, polystyrene, plastic water, nylon and acrylic) was used. It was scanned in 3 CBCTs (i-CAT, Alphard VEGA, Implagraphy SC) and 1 MDCT (Somatom Emotion). The images were saved as DICOM format and CT numbers were measured using OnDemand 3D. CT numbers obtained from CBCTs and MDCT images were compared and linear regression analysis was performed for the density, {rho}(g/cm{sup 3}), as the dependent variable in terms of the CT numbers obtained from CBCTs and MDCT images. CT numbers on i-CAT and Implagraphy CBCT images were smaller than those on Somatom Emotion MDCT image (p<0.05). Linear relationship on a range of materials used for this study were {rho}=0.001 H+1.07 with R2 value of 0.999 for Somatom Emotion, {rho}=0.002 H+1.09 with R2 value of 0.991 for Alphard VEGA, {rho}=0.001 H+1.43 with R2 value of 0.980 for i-CAT and {rho}=0.001 H+1.30 with R2 value of 0.975 for Implagraphy. CT numbers on i-CAT and Implagraphy CBCT images were not same as those on Somatom Emotion MDCT image. The linear regressive equations to determine the density from the CT numbers with very high correlation coefficient were obtained on three CBCT and MDCT scan.

  14. Inter laboratory comparison of industrial CT scanners

    DEFF Research Database (Denmark)

    Angel, Jais Andreas Breusch; Cantatore, Angela; De Chiffre, Leonardo

    2012-01-01

    In this report results from an intercomparison of industrial CT scanners are presented. Three audit items, similar to common industrial parts, were selected for circulation: a single polymer part with complex geometry (Item 1), a simple geometry part made of two polymers (Item 2) and a miniature...

  15. Comparison among different CT ionization chambers

    International Nuclear Information System (INIS)

    Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.

    2015-01-01

    The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)

  16. InteraqCT Comparison on Assemblies - Technical Protocol

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    The InteraqCT comparison on assemblies is as an activity within the Marie Curie ESR Project INTERAQCT - International Network for the Training of Early stage Researchers on Advanced Quality control by Computed Tomography funded by the European Commission's 7th Framework Programme FP7-PEOPLE - Under...

  17. InteraqCT Comparison on Assemblies - Reference Measurements

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    The InteraqCT comparison on assemblies is as an activity within the Marie Curie ESR Project INTERAQCT - International Network for the Training of Early stage Researchers on Advanced Quality control by Computed Tomography funded by the European Commission's 7th Framework Programme FP7-PEOPLE - Under...

  18. Slice sensitivity profiles and pixel noise of multi-slice CT in comparison with single-slice CT

    International Nuclear Information System (INIS)

    Schorn, C.; Obenauer, S.; Funke, M.; Hermann, K.P.; Kopka, L.; Grabbe, E.

    1999-01-01

    Purpose: Presentation and evaluation of slice sensitivity profile and pixel noise of multi-slice CT in comparison to single-slice CT. Methods: Slice sensitivity profiles and pixel noise of a multi-slice CT equiped with a 2D matrix detector array and of a single-slice CT were evaluated in phantom studies. Results: For the single-slice CT the width of the slice sensitivity profiles increased with increasing pitch. In spite of a much higher table speed the slice sensitivity profiles of multi-slice CT were narrower and did not increase with higher pitch. Noise in single-slice CT was independent of pitch. For multi-slice CT noise increased with higher pitch and for the higher pitch decreased slightly with higher detector row collimation. Conclusions: Multi-slice CT provides superior z-resolution and higher volume coverage speed. These qualities fulfill one of the prerequisites for improvement of 3D postprocessing. (orig.) [de

  19. Rectosigmoid endometriosis: comparison between CT water enema and video laparoscopy.

    Science.gov (United States)

    Stabile Ianora, A A; Moschetta, M; Lorusso, F; Lattarulo, S; Telegrafo, M; Rella, L; Scardapane, A

    2013-09-01

    To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Rectosigmoid endometriosis: Comparison between CT water enema and video laparoscopy

    International Nuclear Information System (INIS)

    Stabile Ianora, A.A.; Moschetta, M.; Lorusso, F.; Lattarulo, S.; Telegrafo, M.; Rella, L.; Scardapane, A.

    2013-01-01

    Aim: To evaluate the accuracy of water enema computed tomography (CT) for predicting the location of endometriosis in patients with contraindications to magnetic resonance imaging (MRI), focusing on rectosigmoid lesions and having laparoscopic and histological data as the reference standard. Materials and methods: Thirty-three women (mean age 33.4 ± 3.1 years) suspected of having deep pelvic endometriosis underwent 64-row CT and video laparoscopy within 4 weeks. Two radiologists blinded to the clinical data evaluated the CT images obtained after colonic retrograde distension using water as the contrast medium, and a comparison with laparoscopic and histological findings was performed. CT sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated. The radiation dose to patients was estimated. Cohen's weighted kappa (κ) test was used to evaluate the interobserver agreement. Results: In 23 out of 33 patients (69%) intestinal implants were found at surgery and pathological examinations. CT confirmed the diagnosis of rectosigmoid endometriosis in 20 out of 23 implants. Three nodules located on the proximal sigmoid colon (two serosal lesions and one infiltrating the muscularis layer) with a diameter of less than 1 cm were not diagnosed. CT sensitivity, specificity, PPV, NPV, and accuracy values were 87, 100, 100, 77, and 91%, respectively. The mean effective dose estimate was 6.30 ± 1.7 mSv. Almost perfect agreement between the two readers was found (k = 0.84). Conclusion: Water enema CT can play a role in the diagnosis of bowel endometriosis and represents another accurate potential tool for video laparoscopic approaches, especially in patients for whom MRI is contraindicated

  1. Computer tomography colonography participation and yield in patients under surveillance for 6-9 mm polyps in a population-based screening trial

    NARCIS (Netherlands)

    Tutein Nolthenius, Charlotte J.; Boellaard, Thierry N.; de Haan, Margriet C.; Nio, C. Yung; Thomeer, Maarten G. J.; Bipat, Shandra; Montauban van Swijndregt, Alexander D.; van de Vijver, Marc J.; Biermann, Katharina; Kuipers, Ernst J.; Dekker, Evelien; Stoker, Jaap

    2016-01-01

    Surveillance CT colonography (CTC) is a viable option for 6-9 mm polyps at CTC screening for colorectal cancer. We established participation and diagnostic yield of surveillance and determined overall yield of CTC screening. In an invitational CTC screening trial 82 of 982 participants harboured 6-9

  2. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  3. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  4. Effective radiation dose from semicoronal CT of the sacroiliac joints in comparison with axial CT and conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, Anne Grethe; Boecker Puhakka, Katriina [Department of Radiology R, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark); Hansen, Jolanta [Department of Medical Physics, Aarhus University Hospital, Aarhus Kommunehospital, Noerrebrogade 44, 8000 Aarhus C (Denmark)

    2002-11-01

    The aim of this study was to evaluate the radiation dose given by semicoronal CT of the sacroiliac joints (SIJs) in comparison with axial CT and conventional radiography. The total effective radiation doses given by serial contiguous semicoronal and axial CT, using 5-mm slices, 120 kV and 330 mAs, were determined by measurement of organ doses using an anthropomorphic Rando Alderson phantom paced with thermoluminescence dosimeters. The doses given by conventional antero-posterior (AP) and oblique projections of the SIJs were determined similarly. In a female the total effective dose by semicoronal CT was found to be more than six times lower than by axial CT and 2.5 times lower than the dose use to obtain a conventional AP radiograph, the values being 102, 678, and 255 {mu}Sv, respectively. The effective dose by semicoronal CT was only a little higher than the dose given to obtain two oblique radiographs. In a male with lead protection of the gonads the dose by semicoronal CT was four times lower than by axial CT, but higher than by conventional radiography. In conclusion, the effective dose by semicoronal CT of the SIJs is lower than by axial CT, and in females a semicoronal CT implies a lower effective radiation dose that used to obtain an AP radiograph. (orig.)

  5. MRI of head trauma. Serial changes and comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Osamu; Sato, Shuji; Suzuki, Takashi; Endo, Shunro; Takaku, Akira.

    1988-08-01

    Sequential changes in magnetic resonance imaging (MRI) were investigated in comparison with computed tomography (CT) in 31 cases of head trauma. Twenty-one of them were of acute head trauma; the first MRI study was performed within 48 hours after the accident. Forty-two intracranial lesions were observed in these cases on MRI. The other 10 cases were of chronic subdural hematoma, two cases of which had bilateral lesions. Fourteen lesions of acute head trauma and two lesions of chronic subdural hematoma were detected only by MRI. MRI was superior to CT for the detection of small contusions and thin extra-axial collections, especially those which were located near the bony structures. The abnormal lesions were visualized in MRI during a longer period than in CT. Because the signal intensity of a hematoma changed sequentially, the detection of brain edema was easier than that of a subarachnoid and parenchimal hemorrhage. Judging from this experience, it seems that careful attention should be taken in the diagnosis of hemorrhagic lesions. However, MRI was poor in tissue characterization because of the too-high tissue sensitivity. T/sub 2/-weight SE imaging was essentially sensitive and useful in the early stage.

  6. Diagnostic Performance of Computed Tomography Colonography and Colonoscopy: A Prospective and Validated Analysis of 231 Paired Examinations

    International Nuclear Information System (INIS)

    Arnesen, R.B.; Benzon, E. von; Adamsen, S.; Svendsen, L.B.; Raaschou, H.O.; Hart Hansen, O.

    2007-01-01

    Background: Detection of colorectal tumors with computed tomography colonography (CTC) is an alternative to conventional colonoscopy (CC), and clarification of the diagnostic performance is essential for cost-effective use of both technologies. Purpose: To evaluate the diagnostic performance of CTC compared with CC. Material and Methods: 231 consecutive CTCs were performed prior to same-day scheduled CC. The radiologist and endoscopists were blinded to each other's findings. Patients underwent a polyethylene glycol bowel preparation, and were scanned in prone and supine positions using a single-detector helical CT scanner and commercially available software for image analysis. Findings were validated (matched) in an unblinded comparison with video-recordings of the CCs and re-CCs in cases of doubt. Results: For patients with polyps 5 mm and 10 mm, the sensitivity was 69% (95% CI 58-80%) and 81% (68-94%), and the specificity was 91% (84-98%) and 98% (93-100%), respectively. For detection of polyps 5 mm and 10 mm, the sensitivity was 66% (57-75%) and 77% (65-89%). A flat, elevated low-grade carcinoma was missed by CTC. One cancer relapse was missed by CC, and a cecal cancer was missed by an incomplete CC and follow-up double-contrast barium enema. Conclusion: CC was superior to CTC and should remain first choice for the diagnosis of colorectal polyps. However, for diagnosis of lesions 10 mm, CTC and CC should be considered as complementary methods

  7. Papillary thyroid carcinoma: comparison between CT features and pathologic findings

    International Nuclear Information System (INIS)

    Tan Hongna; Gu Yajia; Peng Weijun; Yang Wentao; Huang Dan

    2009-01-01

    Objective: To evaluate the relationship between the CT imaging features and pathologic findings of papillary thyroid carcinoma (PTC) and papillary thyroid microcarcinoma (PTMC), as well as the CT appearances of Non-papillary thyroid carcinoma(N-PTC). Methods: CT features of 229 PTC, 42 PTMC and 36 N-PTC patients with 264, 57 and 41 lesions respectively were analyzed retrospectively, and comparison was made with the pathologic findings. All data were analyzed by X 2 test. Results: (1) Of PTC lesions, 25.4% (67/264)of the lesions and 2.9% (24/828) of metastatic lymph nodes showed cystic changes. Cyst formation with intracystic high density papillary-like nodules were found in 31.3% (21/67)of the PTC lesions and 37.5% (9/24) of metastatic lymph nodes. The histologic appearances of these tumors demonstrated fibrous tissue forming the wall of cyst, and papillary-like tumor tissue. (2) 75.2% (112/149) of PTC and 33.3% (5/15) of PTMC showed multiple small granular and fine calcifications, and there was statiscally significant difference between the two (P 0.05). However, the degree of enhancement in PTC lesions were less than that of N-PTC, 36.6% (94/257) of PTC and 54.1% (20/37)of N-PTC lesions showed significant enhancement, and there was statistically significant difference (P<0.05). 75.1% of PTC (172/229) and 52.8% of (19/36)N-PTC had cervical lymph node metastases, with a propensity fbr PTC to have more VI region metastatic lymph nodes, 80.8% (139/172)vs 57.9% (11/19), which was statistically significant (both P<0.05). (4)Distant metastases to bone or lung were rare, but N-PTC (5/36) were more likely to produce distant metastases than PTC (5/229), and there was statistically significant difference (P<0.01). Conclusion Multiple, small granular and fine calcifications were found more frequently in PTC than PTMC. Compared with N-PTC, the papillary-like mural nodules of PTC showed less enhancement on post-contrast CT and cervical lymph node metastases were more

  8. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    International Nuclear Information System (INIS)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao; Tabacchi, Elena; Fanti, Stefano; Delbeke, Dominique; Giacometti Sakamoto, Danielle

    2017-01-01

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  9. Comparison of CT and PET/CT for biopsy guidance in oncological patients

    Energy Technology Data Exchange (ETDEWEB)

    Cerci, Juliano J.; Bogoni, Mateos; Cunha Pereira, Carlos; Cerci, Rodrigo J.; Krauzer, Cassiano; Vicente Vitola, Joao [Quanta - Diagnostico e Terapia, Curitiba, PR (Brazil); Tabacchi, Elena; Fanti, Stefano [University Hospital S. Orsola-Malpighi, Nuclear Medicine Department, Bologna (Italy); Delbeke, Dominique [Vanderbilt University, Nashville, TN (United States); Giacometti Sakamoto, Danielle [Byori - Laboratorio de Patologia, Curitiba (Brazil)

    2017-08-15

    To compare FDG PET/CT and CT for the guidance of percutaneous biopsies with histological confirmation of lesions. We prospectively evaluated 323 patients of whom 181 underwent FDG PET/CT-guided biopsy (total 188 biopsies) and 142 underwent CT-guided biopsy (total 146 biopsies). Biopsies were performed using the same PET/CT scanner with a fluoroscopic imaging system. Technical feasibility, clinical success and complication rates in the two groups were evaluated. Of the 188 biopsies with PET/CT guidance, 182 (96.8%) were successful with conclusive tissue samples obtained and of the 146 biopsies with CT guidance, 137 (93.8%) were successful. Therefore, 6 of 188 biopsies (3.1%) with PET/CT guidance and 9 of 146 (6.1%) with CT guidance were inconclusive (p = 0.19). Due to inconclusive histological results, 4 of the 188 lesions (2.1%) were rebiopsied with PET/CT guidance and 3 of 146 lesions (2.0%) were rebiopsied with CT guidance. Histology demonstrated that 142 of 188 lesions (75.5%) were malignant, and 40 (21.2%) were benign in the PET/CT-guided group, while 89 of 146 lesions (60.9%) were malignant and 48 (32.8%) were benign in the CT-guided group (p = 0.004 and 0.01, respectively). Patients with a histological diagnosis of benign lesion had no recurrence of disease with a minimum of 6 months follow-up. Of the 188 PET/CT-guided biopsies, 6 (3.1%) were repeat biopsies due to a previous nondiagnostic CT-guided biopsy performed in a different diagnostic centre. The interval between the two biopsies was less than a month in all cases. Histology revealed five malignant lesions and one benign lesion among these. The complication rate in the PET/CT-guided biopsy group was 12.7% (24 of 188), while in the CT-guided group, was 9.5% (14 of 146, p = 0.26). Therefore, there was no significant difference in complication rates between PET/CT and CT guidance. PET/CT-guided biopsy is already known to be a feasible and accurate method in the diagnostic work-up of suspected malignant

  10. Interlaboratory Comparison of a physical and a virtual assembly measured by CT

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2018-01-01

    In a comparison including 20 laboratories, a physical as well as a virtual assembly provided as two data sets were used to investigate measuring and post-processing approaches in Computed Tomography, CT. Different procedures were used in the comparison including one simulating in-line measurement....... The comparison demonstrated that: (i) a tangible improvement in the use of CT compared to previous comparisons; (ii) most of the participants were able to reduce their scanning time by more than 70% without increasing the length measurement errors; and (iii) most of the participants can further reduce...... their uncertainties, thereby reducing the tolerance size that can be inspected using CT in industry....

  11. Traumatic brain injury: Comparison between autopsy and ante-mortem CT.

    Science.gov (United States)

    Panzer, Stephanie; Covaliov, Lidia; Augat, Peter; Peschel, Oliver

    2017-11-01

    The aim of this study was to compare pathological findings after traumatic brain injury between autopsy and ante-mortem computed tomography (CT). A second aim was to identify changes in these findings between the primary posttraumatic CT and the last follow-up CT before death. Through the collaboration between clinical radiology and forensic medicine, 45 patients with traumatic brain injury were investigated. These patients had undergone ante-mortem CT as well as autopsy. During autopsy, the brain was cut in fronto-parallel slices directly after removal without additional fixation or subsequent histology. Typical findings of traumatic brain injury were compared between autopsy and radiology. Additionally, these findings were compared between the primary CT and the last follow-up CT before death. The comparison between autopsy and radiology revealed a high specificity (≥80%) in most of the findings. Sensitivity and positive predictive value were high (≥80%) in almost half of the findings. Sixteen patients had undergone craniotomy with subsequent follow-up CT. Thirteen conservatively treated patients had undergone a follow-up CT. Comparison between the primary CT and the last ante-mortem CT revealed marked changes in the presence and absence of findings, especially in patients with severe traumatic brain injury requiring decompression craniotomy. The main pathological findings of traumatic brain injury were comparable between clinical ante-mortem CT examinations and autopsy. Comparison between the primary CT after trauma and the last ante-mortem CT revealed marked changes in the findings, especially in patients with severe traumatic brain injury. Hence, clinically routine ante-mortem CT should be included in the process of autopsy interpretation. Copyright © 2017 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  12. Colon dissection: a new three-dimensional reconstruction tool for computed tomography colonography

    International Nuclear Information System (INIS)

    Roettgen, R.; Fischbach, F.; Plotkin, M.; Herzog, H.; Freund, T.; Schroeder, R. J.; Felix, R.

    2005-01-01

    Purpose: To improve the sensitivity of computed tomography (CT) colonography in the detection of polyps by comparing the 3D reconstruction tool 'colon dissection' and endoluminal view (virtual colonoscopy) with axial 2D reconstructions. Material and Methods: Forty-eight patients (22 M, 26 F, mean age 57±21) were studied after intra-anal air insufflation in the supine and prone positions using a 16-slice helical CT (16x0.625 mm, pitch 1.7; detector rotation time 0.5 s; 160 mAs und 120 kV) and conventional colonoscopy. Two radiologists blinded to the results of the conventional colonoscopy analyzed the 3D reconstruction in virtual-endoscopy mode, in colon-dissection mode, and axial 2D slices. Results: Conventional colonoscopy revealed a total of 35 polyps in 15 patients; 33 polyps were disclosed by CT methods. Sensitivity and specificity for detecting colon polyps were 94% and 94%, respectively, when using the 'colon dissection', 89% and 94% when using 'virtual endoscopy', and 62% and 100% when using axial 2D reconstruction. Sensitivity in relation to the diameter of colon polyps with 'colon dissection', 'virtual colonoscopy', and axial 2D-slices was: polyps with a diameter >5.0 mm, 100%, 100%, and 71%, respectively; polyps with a diameter of between 3 and 4.9 mm, 92%, 85%, and 46%; and polyps with a diameter <3 mm, 89%, 78%, and 56%. The difference between 'virtual endoscopy' and 'colon dissection' in diagnosing polyps up to 4.9 mm in diameter was statistically significant. Conclusion: 3D reconstruction software 'colon dissection' improves sensitivity of CT colonography compared with the endoluminal view

  13. Comparison SPECT-CT with PET-CT in several applications of small-animal models

    International Nuclear Information System (INIS)

    Pan Yifan; Song Shaoli; Huang Gang

    2009-01-01

    With the development of medical science, monitoring dynamic biologic processes in small-animal models of diseases has become one of the most important approaches in medical studies. Important physiologic parameters that traditionally have been characterized by nuclear medicine imaging include blood flow, biochemical metabolism, and cellular receptors. Recently, nuclear medicine has been greatly facilitated by the newer development of dual-modality integrated imaging systems (SPECT-CT and PET-CT), which provide functional and anatomical images in the same scanning session, with the acquired images co-registered by means of the hardware. The purpose of this review is to compare SPECT-CT with PET-CT in several applications of small-animal models. Conclusicn: PET-CT for small animal modes in nledical research in the applications has great advantages, but SPECT-CT is still a very important role, and research low cost. (authors)

  14. Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: Pilot study

    International Nuclear Information System (INIS)

    Li Ping; Napel, Sandy; Acar, Burak; Paik, David S.; Jeffrey, R. Brooke Jr.; Beaulieu, Christopher F.

    2004-01-01

    Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration

  15. Computed tomographic colonography (CTC); colorectal cancer diagnosis with CTC in an Auckland population

    International Nuclear Information System (INIS)

    Moore, Helen; Dodd, Nicholas

    2013-01-01

    To determine the sensitivity of computed tomographic colonography (CTC) in the detection of colorectal cancer in our population and evaluate the reasons why these lesions may be missed on CTC. All patients who underwent CTC in the 65-month period from 1 January 2004 to 1 July 2009 were included in the analysis. Demographic data and CTC findings were recorded, according to the CT Colonography Reporting and Data System. Data were cross-matched with the National Cancer Registry results for colorectal cancer cases between 1 January 2004 and 1 October 2009, 3 months longer to include any delayed diagnoses. There were 2026 consecutive CTC patients, comprising 52.6% female, average age of 60 years; range 19–87. Approximately 84% were symptomatic. There were 45 confirmed colorectal cancers among this patient group in the National Cancer Registry during the relevant time period compared with 43 suspected cancers on CTC, giving a miss rate of 2 of 45, or 4.4%. The sensitivity of 95% for CTC in the detection of colorectal cancer compares favourably with the published national and international data.

  16. CT-based virtual tracheobronchoscopy in children - comparison with axial CT and multiplanar reconstruction: preliminary results

    International Nuclear Information System (INIS)

    Sorantin, Erich; Lindbichler, Franz; Eber, Ernst; Schimpl, Guenther

    2002-01-01

    Background: 3D post-processing of spiral-CT (S-CT) data using perspective projection allows the generation of virtual views similar to endoscopy. Objective: To evaluate whether simultaneous reading of axial S-CT, multiplanar reconstruction (MPR) and virtual tracheobronchoscopy (VTB) is more precise and accurate than reading of axial S-CT and MPR alone in paediatric patients. Materials and methods: S-CT studies of 15 symptomatic and 4 normal patients were investigated. Two radiologists independently read two sets of images for airway abnormalities: first axial CT and MPR, followed by axial CT, MPR and VTB. A final decision was later made by consensus. All results were compared to fibre-optic bronchoscopy (FTB). Interobserver agreement was used as an indicator of precision for the display technique used. Results: At reading of axial S-CT and MPR an interobserver agreement of 89.5% (κ=0.776, P<0.00103) was found. Based on the consensus decision, a diagnostic accuracy of 89.5% at a sensitivity 86.6% and specificity of 100% (κ=0.776, 95% CI 0.491-1.062, P<0.00103) was achieved. At reporting on axial S-CT, MPR and VTB, all cases were classified correctly by both readers, indicating 100% accuracy, interobserver agreement, sensitivity and specificity (κ=1.00, 95% CI 1.0-1.0, P<0.000258). Conclusions: The simultaneous display of axial S-CT, MPR and VTB raises the precision, accuracy and sensitivity of radiological reports. (orig.)

  17. Comparison of CT and MRI features in sinusitis

    International Nuclear Information System (INIS)

    Chong, V.F.H.; Fan, Y.F.

    1998-01-01

    Objective: To correlate the features of inflammatory changes in the paranasal sinuses on magnetic resonance imaging (MRI) with computed tomography (CT). Methods and patients: One hundred and fourteen patients with histologically proven nasopharyngeal carcinoma (NPC) were staged with both CT and MRI. All CT and MRI images of patients with mucosal thickening but no tumour involvement of the sinuses were retrospectively analysed. Results: There were inflammatory changes in 36 maxillary, 21 sphenoid and 16 ethmoid sinuses. These changes include mucosal thickening, retention cysts, retained secretions, inspissated secretions and dystrophic calcification. MRI is superior to CT in separating thickened mucosa, retained secretions and retentions cysts. Conclusion: It is important to appreciate CT changes of sinusitis and the corresponding spectrum of MRI features. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  18. Comparison of CT and scintigraphy in diseases of the liver

    International Nuclear Information System (INIS)

    Wenig, H.G.; Wegener, O.H.; Souchon, R.; Ziegler, U.; Koppenhagen, K.

    1979-01-01

    Sixty-five patients with various diseases of the liver were examined by CT and scintigraphy. We found the following preliminary conclusions: diffusely infiltrative and hepatocellular diseases of the liver, espacially cirrhosis, are recognized on CT by shape and contour rather than by density values. In these cases, scintigraphy provides important information about the function of the parenchyma. In space-occupying processes, a close correlation exists between CT and scintigraphy. In the investigation of liver metastases in advanced stages, CT and radionuclide studies proved to be nearly identical in accuracy. The advantages of CT consist in the possibility of showing more morphologic detail of adjacent organs and in possessing better spatial resolution. (orig.) 891 MG/orig. 892 MB [de

  19. Interobserver variability in visual evaluation of thoracic CT scans and comparison with automatic computer measurements of CT lung density

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Thomsen, Laura Hohwü; Dirksen, Asger

    2012-01-01

    lung density measurements, i.e. densitometry. Methods – In a pilot study 60 CT scans were selected from a sample of 3980 CT scans from The Danish Lung Cancer Screening Trial (DLCST). The amount of emphysema in these scans was scored independently by two observers, who were blinded regarding clinical...... information. The lung was segmented automatically by in-house developed computer software, and the percentage of pixels below -950 HU was used as a surrogate marker for emphysema. The observer variability, as well as the correlation with the lung density measurements, was analysed using Spearman’s rank...... in emphysema grading. However, the agreement with the CT lung density measurement was poor, indicating that the two types of evaluation represent different aspects of emphysema. Most likely, they should be seen as complementary rather than competitive evaluations. Future comparison with physiological tests...

  20. NMR characteristics of low-grade glioma. Comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Reinin; Tokuriki, Yasuhiko; Nakano, Yoshihisa; Itoh, Harumi; Torizuka, Kanji; Ueda, Tohru; Yamashita, Junkoh; Handa, Hajime

    1985-08-01

    Sixteen low-grade gliomas were evaluated both with nuclear magnetic resonance (NMR) imaging and with computed tomography (CT). In 13 cases (81%), the NMR images were much better in tissue contrast than the contrast-enhanced CT images. The tumors were shown as well-circumscribed oval lesions in the NMR, though they appeared as ill-defined, irregular, low-attenuation areas in the CT. The extent of the lesion, which was supposed to represent the active tumor tissue, was greater in the NMR than in the CT, because NMR tissue parameters (T/sub 1/, T/sub 2/) are more sensitive to pathological changes in brain tissue than is the X-ray attenuation coefficient. Though, in an optic glioma and a brain-stem astrocytoma, the CT with contrast enhancement displayed the contour of the mass as well as did NMR, it was inferior to the NMR in showing the cephalocaudal extension of the tumors. Calcification does not give a proton NMR signal under the present measuring conditions; thus the calcified cystic wall of a hypothalamic astrocytoma was displayed only in the CT images. In conclusion, the NMR imaging was apparently superior to contrast-enhanced CT in demonstrating the lesions due to low-grade glioma.

  1. Comparison of CT scanning and radionuclide imaging in liver disease

    International Nuclear Information System (INIS)

    Friedman, M.L.; Esposito, F.S.

    1980-01-01

    Early experience with body CT suggested its usefulness in many diagnostic problems; jaundice, renal and pancreatic masses, and in the evaluation of relatively inaccessible parts of the body, such as the retroperitineum, mediastinum, and pelvis. Investigation of hepatic disease by CT was not unexpectedly compared to radionuclide liver scanning, the major preexisting modality for imaging the liver. In the evaluation of the jaundiced patient, CT rapidly assumed a major role, providing more specific information about the liver than the RN liver scan, as well as demonstrating adjacent organs. CT differentiate obstructive from non-obstructive jaundice. With respect to mass lesions of the liver, the RN liver scan is more sensitive than CT but less specific. The abnormalities on an isotope image of the liver consist of normal variants in configuration, extrinsic compression by adjacent structures, cysts, hemangiomata, abscesses, and neoplasms. These suspected lesions may then be better delineated by the CT image, and a more precise diagnosis made. The physiologic information provided by the RN liver scan is an added facet which is helpful in the patient with diffuse hepatic disease. The CT image will be normal in many of these patients, however, hemochromatosis and fatty infiltration lend themselves especially to density evaluation by CT. The evaluation of lymphoma is more thorough with CT. Structures other than the liver, such as lymph nodes, are visualized. Gallium, however, provides additional isotopic information in patients with lymphoma, and in addition, is known to be useful in the investigation of a febrile patient with an abscess. Newer isotopic agents expand hepatic imaging in other directions, visualizing the biliary tree and evaluating the jaundiced patient

  2. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  3. Correlative Imaging in a Patient with Cystic Thymoma: CT, MR and PET/CT Comparison

    International Nuclear Information System (INIS)

    Romeo, Valeria; Esposito, Alfredo; Maurea, Simone; Camera, Luigi; Mainenti, Pier Paolo; Palmieri, Giovannella; Buonerba, Carlo; Salvatore, Marco

    2015-01-01

    Cystic thymoma is a rare variant of thymic neoplasm characterized by almost complete cystic degeneration with mixed internal structure. We describe a case of a 60 year-old woman with a cystic thymoma studied with advanced tomographic imaging stydies. CT, MRI and PET/CT with 18 F-FDG were performed; volumetric CT and MRI images provided better anatomic evaluation for pre-operative assessment, while PET/CT was helpful for lesion characterization based on 18 F-FDG uptake. Although imaging studies are mandatory for pre-operative evaluation of cystic thymoma, final diagnosis still remains surgical. A 60-year-old woman with recent chest pain and no history of previous disease was admitted to our departement to investigate the result of a previous chest X-ray that showed bilateral mediastinal enlargement; for this purpose, enhanced chest CT scan was performed using a 64-rows scanner (Toshiba, Aquilion 64, Japan) before and after intravenous bolus administration of iodinated non ionic contrast agent; CT images demonstrated the presence of a large mediastinal mass (11×8 cm) located in the anterior mediastinum who extended from the anonymous vein to the cardio-phrenic space, compressing the left atrium and causing medium lobe atelectasis; bilateral pleural effusion was also present. In conclusion, correlative imaging plays a foundamental role for the diagnostic evaluation of patient with cystic thymoma. In particular, volumetric CT and MRI studies can provide better anatomic informations regarding internal structure and local tumor spread for pre-operative assessment. Conversely, metabolic imaging using 18 F-FDG PET/CT is helpful for lesion characterization differentiating benign from malignant lesion on the basis of intense tracer uptake. The role of PET/MRI is still under investigation. However, final diagnosis still remains surgical even though imaging studies are mandatory for pre-operative patient management

  4. Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities.

    Science.gov (United States)

    Lechuga, Lawrence; Weidlich, Georg A

    2016-09-12

    A comparison of image quality and dose delivered between two differing computed tomography (CT) imaging modalities-fan beam and cone beam-was performed. A literature review of quantitative analyses for various image quality aspects such as uniformity, signal-to-noise ratio, artifact presence, spatial resolution, modulation transfer function (MTF), and low contrast resolution was generated. With these aspects quantified, cone beam computed tomography (CBCT) shows a superior spatial resolution to that of fan beam, while fan beam shows a greater ability to produce clear and anatomically correct images with better soft tissue differentiation. The results indicate that fan beam CT produces superior images to that of on-board imaging (OBI) cone beam CT systems, while providing a considerably less dose to the patient.

  5. Dosimetry comparison of pelvimetry methods using conventional radiographs and CT

    International Nuclear Information System (INIS)

    Resten, A.; Suissa, M.; Musset, D.; Mausoleo, F.; Valero, M.; Taylor, S.

    2001-01-01

    To determine the fetal and maternal exposure to radiation by use of thermoluminescent dosimeters in order to compare conventional and CT-scan X-ray. Dosimetry was performed with an anthropomorph phantom. Thermoluminescent dosimeters were positioned on the surface and in the depth of the phantom. Digital radiography of the pelvis was performed according to a standard technique. CT-scan of the pelvis was performed according to the Buthiau's technique. With CT, the dose reached 0.31 to 4.95 mGy, with a dose of 2.32 mGy for the fetal gonads. With standard technique, the doses reached 0.03 to 0.39 mGy, with a dose of 0.39 mGy for the fetal gonads. With CT the fetus and the mother were exposed to 1/10. of the total dose delivered using conventional X-rays and the dose distribution was more homogeneous. (author)

  6. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  7. Comparison of air space measurement imaged by CT, small-animal CT, and hyperpolarized Xe MRI

    Science.gov (United States)

    Madani, Aniseh; White, Steven; Santyr, Giles; Cunningham, Ian

    2005-04-01

    Lung disease is the third leading cause of death in the western world. Lung air volume measurements are thought to be early indicators of lung disease and markers in pharmaceutical research. The purpose of this work is to develop a lung phantom for assessing and comparing the quantitative accuracy of hyperpolarized xenon 129 magnetic resonance imaging (HP 129Xe MRI), conventional computed tomography (HRCT), and highresolution small-animal CTCT) in measuring lung gas volumes. We developed a lung phantom consisting of solid cellulose acetate spheres (1, 2, 3, 4 and 5 mm diameter) uniformly packed in circulated air or HP 129Xe gas. Air volume is estimated based on simple thresholding algorithm. Truth is calculated from the sphere diameters and validated using μCT. While this phantom is not anthropomorphic, it enables us to directly measure air space volume and compare these imaging methods as a function of sphere diameter for the first time. HP 129Xe MRI requires partial volume analysis to distinguish regions with and without 129Xe gas and results are within %5 of truth but settling of the heavy 129Xe gas complicates this analysis. Conventional CT demonstrated partial-volume artifacts for the 1mm spheres. μCT gives the most accurate air-volume results. Conventional CT and HP 129Xe MRI give similar results although non-uniform densities of 129Xe require more sophisticated algorithms than simple thresholding. The threshold required to give the true air volume in both HRCT and μCT, varies with sphere diameters calling into question the validity of thresholding method.

  8. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Dullerud, R. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology; Johansen, J.G. [Ullevaal Univ. Hospital, Oslo (Norway). Section of Neuroradiology

    1995-09-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG).

  9. CT-diskography in patients with sciatica. Comparison with plain CT and MR imaging

    International Nuclear Information System (INIS)

    Dullerud, R.; Johansen, J.G.

    1995-01-01

    The findings at CT-diskography (CT-D), including recording of the pain introduced at contrast injection, were compared with plain CT and MR imaging in 111 disks in 101 patients aged 18 to 68 years. Six disks which were normal at CT had normal CT-D and 5 of them had normal signal on MR imaging. The degree of annular degeneration and the depth of the annular tears were significantly associated with each other and with loss of disk height, but not with size or location of the hernias. Only the depth of the tears was significantly associated with loss of signal on MR. However, frequently complete annular tears and severe annular degeneration were seen in association with small bulges and hernias, even in disks with normal or slightly reduced signal on MR and with normal height. The type and intensity of the pain introduced were associated with each other and with the depth of the annular tears, but not with the degree of annular degeneration, size of the hernia or the MR signal intensity of the disks. Annular degeneration and tears on one hand, and the type and intensity of pain introduced on the other, see to be related rather than separate phenomena. (orig./MG)

  10. Spectral CT of carotid atherosclerotic plaque: comparison with histology

    Energy Technology Data Exchange (ETDEWEB)

    Zainon, R.; Doesburg, R.M. [University of Canterbury, Department of Physics and Astronomy, Christchurch (New Zealand); Ronaldson, J.P.; Gieseg, S.P. [University of Otago, Centre for Bioengineering, Christchurch (New Zealand); Janmale, T. [University of Canterbury, Free Radical Biochemistry Laboratory, School of Biological Sciences, Christchurch (New Zealand); Scott, N.J. [University of Otago, Department of Medicine, Christchurch (New Zealand); Buckenham, T.M. [University of Otago, Department of Academic Radiology, Christchurch (New Zealand); Butler, A.P.H. [University of Otago, Centre for Bioengineering, Christchurch (New Zealand); University of Otago, Department of Academic Radiology, Christchurch (New Zealand); University of Canterbury, Department of Electrical and Computer Engineering, Christchurch (New Zealand); European Organisation for Nuclear Research (CERN), Geneva (Switzerland); Butler, P.H. [University of Canterbury, Department of Physics and Astronomy, Christchurch (New Zealand); European Organisation for Nuclear Research (CERN), Geneva (Switzerland); Roake, J.A. [Christchurch Hospital, Department of Vascular, Endovascular and Transplant Surgery, Christchurch (New Zealand); Anderson, N.G. [University of Otago, Centre for Bioengineering, Christchurch (New Zealand); University of Otago, Department of Academic Radiology, Christchurch (New Zealand); University of Otago, Christchurch, Department of Radiology, PO Box 4345, Christchurch (New Zealand)

    2012-12-15

    To distinguish components of vulnerable atherosclerotic plaque by imaging their energy response using spectral CT and comparing images with histology. After spectroscopic calibration using phantoms of plaque surrogates, excised human carotid atherosclerotic plaques were imaged using MARS CT using a photon-processing detector with a silicon sensor layer and microfocus X-ray tube (50 kVp, 0.5 mA) at 38-{mu}m voxel size. The plaques were imaged, sectioned and re-imaged using four threshold energies: 10, 16, 22 and 28 keV; then sequentially stained with modified Von Kossa, Perl's Prussian blue and Oil-Red O, and photographed. Relative Hounsfield units across the energies were entered into a linear algebraic material decomposition model to identify the unknown plaque components. Lipid, calcium, iron and water-like components of plaque have distinguishable energy responses to X-ray, visible on spectral CT images. CT images of the plaque surface correlated very well with histological photographs. Calcium deposits (>1,000 {mu}m) in plaque are larger than iron deposits (<100 {mu}m), but could not be distinguished from each other within the same voxel using the energy range available. Spectral CT displays energy information in image form at high spatial resolution, enhancing the intrinsic contrast of lipid, calcium and iron within atheroma. (orig.)

  11. Radiation doses in head CT examinations in Serbia: comparison among different CT units

    International Nuclear Information System (INIS)

    Arandjic, D.; Ciraj-Bjelac, O.; Bozovic, P.; Stankovic, J.; Hadnadjev, D.; Stojanovic, S.

    2012-01-01

    A rapid increase in number of Computed Tomography (CT) examinations has been observed world wide. As haed CT is the most frequent CT examination, the purpose of this study was to collect and analyse patient doses in children and adults in different CT units for this procedure. The study included 8 CT units from three manufacturers (Siemens, Toshiba and General Electric). Data for adults and pediatric patients were collected in terms of CTDIvol and DLP values. The doses were estimated as a mean value of 10 patients on each CT unit. For pediatrics, doses were collected for four age groups (0-1year, >1-5years, >5-10years and >10-15years). Comparing different manufacturers and the same number of detector rows it was observed that, in case of 16 slices units, doses were very similar on Siemens and General Electric scanner. CTDIvol and DLP on Siemens scanner were 60 mGy and 1066 mGy·cm, respectively, while on General Electric those values were 66 mGy and 1050 mGy·cm. However, this trend was not observed in case of 64 slices units. CTDIvol and DLP values collected on Toshiba were much higher (177 mGy and 2109 mGy·cm) than in case of Siemens scanner (59 mGy and 1060 mGy·cm). Doses on 16 and 64 slices Siemens scanners were very similar, while on 4 slices were higher. Except in two units, doses were were in line with DRLs. In case of pediatrics, doses increase with patient age and again Siemens scanner showed the lowest values while the highest were observed on Toshiba. (authors)

  12. Patient doses in chest CT examinations: Comparison of various CT scanners

    Directory of Open Access Journals (Sweden)

    Božović Predrag

    2013-01-01

    Full Text Available This paper presents results from study on patient exposure level in chest CT examinations. CT scanners used in this study were various Siemens and General Electric (GE models. Data on patient doses were collected for adult and pediatric patients. Doses measured for adult patients were lower then those determined as Diagnostic Reference Levels (DRL for Europe, while doses for pediatric patients were similar to those found in published data. As for the manufactures, slightly higher doses were measured on GE devices, both for adult and pediatric patients.

  13. Assessment of effective dose from cone beam CT imaging in SPECT/CT examination in comparison with other modalities

    International Nuclear Information System (INIS)

    Tonkopi, Elena; Ross, Andrew A.

    2016-01-01

    The aim of this study was to assess radiation dose from the cone beam computed tomography (CBCT) component of single photon emission tomography/computed tomography (SPECT/CT) examinations and to compare it with the radiopharmaceutical related dose as well as dose from multidetector computed tomography (MDCT). Effective dose (ED) from computed tomography (CT) was estimated using dose-length product values and anatomy-specific conversion factors. The contribution from the SPECT component was evaluated using ED per unit administered activity for the radiopharmaceuticals listed in the International Commission on Radiological Protection Publications 80 and 106. With the exception of cardiac studies (0.11 mSv), the CBCT dose (3.96-6.04 mSv) was similar to that from the radiopharmaceutical accounting for 29-56 % of the total ED from the examination. In comparison with MDCT examinations, the CBCT dose was 48 and 42 % lower for abdomen/pelvis and chest/abdomen/pelvis scans, respectively, while in the chest the CBCT scan resulted in higher dose (23 %). Radiation dose from the CT component should be taken into consideration when evaluating total SPECT/CT patient dose. (authors)

  14. Detection of lung nodules with low-dose spiral CT: comparison with conventional dose CT

    International Nuclear Information System (INIS)

    Zhu Tianzhao; Tang Guangjian; Jiang Xuexiang

    2004-01-01

    Objective: To investigate the effect of reducing scan dose on the lung nodules detection rate by scanning a lung nodule model at low dose and conventional dose. Methods: The lung and the thoracic cage were simulated by using a cyst filled with water surrounded by a roll bandage. Flour, butter, and paraffin wax were mixed together by a certain ratio to simulate lung nodules of 10 mm and 5 mm in diameter with the CT values ranging from -10 to 50 HU. Conventional-dose scan (240 mA, 140 kV) and low-dose scan of three different levels (43 mA, 140 kV; 50 mA, 120 kV; 75 mA, 80 kV) together with three different pitches (1.0, 1.5, and 2.0) were performed. The images of the simulated nodules were combined with the CT images of a normal adult's upper, middle, and inferior lung. Three radiologists read the images and the number of the nodules they detected including both the real ones and the false-positive ones was calculated to investigate weather there was any difference among different doses, pitch groups, and different locations. Results: The detection rate of the 10 mm and 5 mm nodules was 100% and 89.6% respectively by the low-dose scan. There was no difference between low-dose and conventional-dose CT (χ 2 =0.6907, P>0.70). The detection rate of 5 mm nodules declined when large pitch was used. Conclusion: The detection rates of 10 mm and 5 mm nodules had no difference between low-dose CT and conventional-dose CT. As the pitch augmented, the detection rate for the nodules declined

  15. CT findings of laryngeal tuberculosis : comparison with laryngeal carcinoma

    International Nuclear Information System (INIS)

    Kim, Man Deuk; Kim, Dong Ik; Lee, Byung Hee; Sung, Ki Joon; Jung, Tae Sub; Cho, Jae Min; Yune, Heun Yune; Kim, Sun Yong

    1996-01-01

    To determine the value of CT(Computerized Tomography) in the diagnosis of laryngeal tuberculosis and to assess to what extent its characteristic findings different from those of laryngeal carcinoma. CT scans of twelve patients with laryngeal tuberculosis were reviewed and compared with those of fifteen patients with laryngeal cancer, retrospectively. Clinical symptoms, laryngoscopic examinations and the presence of pulmonary tuberculosis chest radiographs were also reviewed. In laryngeal tuberculosis, bilateral symmetric or asymmetric involvement was noted in nine(75%) patients, while unilateral involvement was seen in three(25%). This was significantly different from laryngeal cancer in which unilateral involvement was noted in twelve patients(80%). Diffuse thickening of the free margin of the epiglottis was a characteristic and frequent finding in tuberculosis(n=6, 50%). No deep submucosal infiltration of preepiglottic and paralaryngeal fat spaces is seen in tuberculosis in spite of large areas of involvement of laryngeal mucosa, while twelve patients(80%) with laryngeal cancer showed thickened deep infiltration which resulted in a submucosal mass. CT was useful in the diagnosis of laryngeal tuberculosis and its CT findings were characterized by bilateral involvement, thickening of the free margin of the epiglottis and good preservation of preepiglottic and paralaryngeal fat spaces in spite of large areas of involvement

  16. Atelectasis on pediatric chest CT: comparison of sedation techniques

    International Nuclear Information System (INIS)

    Sargent, M.A.; McEachern, A.M.; Jamieson, D.H.

    1999-01-01

    Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). Conclusion. Atelectasis is more frequent and more severe in children undergoing general anesthesia compared with intravenous pentobarbital sedation. Consideration should be given to the use of forced inspiration in children anesthetized for CT scan of the chest. (orig.)

  17. Technical quality of CT colonography in relation with diverticular disease

    International Nuclear Information System (INIS)

    Flor, Nicola; Rigamonti, Paolo; Di Leo, Giovanni; Ceretti, Andrea Pisani; Opocher, Enrico; Sardanelli, Francesco; Cornalba, Gian Paolo

    2012-01-01

    Objective: The aim of the study is to explore how the technical quality of the examination was affected by diverticular disease. Materials and methods: We retrospectively evaluated a consecutive series of 78 subjects who underwent CTC for screening (n = 58) or staging (n = 20) colorectal cancer, 38 of them (49%) after an incomplete optical colonoscopy. Patients were administered a mild laxative and a iodinated contrast material for fecal tagging. We scored both the bowel preparation and the overall colon distension as poor, good, or optimal and measured the mean sigmoid colon diameter. We counted the number of diverticula and classified patients as having or not a severe diverticular disease (SDD). The number of the prompts of computer aided diagnosis (CAD) per patient was also considered. Mann–Whitney U and χ 2 tests were performed. Results: No CTC complications occurred. The bowel cleansing was poor in 8 (10%) patients, good in 29 (37%) and optimal in 41 (53%); colon distension was poor in 7 (9%) patients, good in 38 (49%), and optimal in 33 (42%). Fifty-four (69%) showed diverticula and 30 (38%) had an SDD. Bowel cleansing and distension were not significantly impaired by neither diverticula (p > 0.590) nor the SDD (p > 0.110). Mean sigmoid colon diameter was reduced in presence of diverticula (28 mm versus 23 mm, p = 0.009) or SDD (26 mm versus 22 mm, p = 0.016). The mean number of CAD prompts per patient was not significantly increased by the presence of SDD (p = 0.829). Conclusions: Bowel cleansing and distension at CTC were not influenced by the presence of diverticular disease.

  18. Potential pitfalls in the anorectal region during CT colonography: A ...

    African Journals Online (AJOL)

    2017-02-28

    Feb 28, 2017 ... smart phone or ... require further investigation and may require just a digital rectal ... pathology-related pitfalls (internal haemorrhoids, polyps, cancer, ... interpretation problems.12 It is preferable to use a small gauge (25 Fr.

  19. The Cryosphere Model Comparison Tool (CmCt): Ice Sheet Model Validation and Comparison Tool for Greenland and Antarctica

    Science.gov (United States)

    Simon, E.; Nowicki, S.; Neumann, T.; Tyahla, L.; Saba, J. L.; Guerber, J. R.; Bonin, J. A.; DiMarzio, J. P.

    2017-12-01

    The Cryosphere model Comparison tool (CmCt) is a web based ice sheet model validation tool that is being developed by NASA to facilitate direct comparison between observational data and various ice sheet models. The CmCt allows the user to take advantage of several decades worth of observations from Greenland and Antarctica. Currently, the CmCt can be used to compare ice sheet models provided by the user with remotely sensed satellite data from ICESat (Ice, Cloud, and land Elevation Satellite) laser altimetry, GRACE (Gravity Recovery and Climate Experiment) satellite, and radar altimetry (ERS-1, ERS-2, and Envisat). One or more models can be uploaded through the CmCt website and compared with observational data, or compared to each other or other models. The CmCt calculates statistics on the differences between the model and observations, and other quantitative and qualitative metrics, which can be used to evaluate the different model simulations against the observations. The qualitative metrics consist of a range of visual outputs and the quantitative metrics consist of several whole-ice-sheet scalar values that can be used to assign an overall score to a particular simulation. The comparison results from CmCt are useful in quantifying improvements within a specific model (or within a class of models) as a result of differences in model dynamics (e.g., shallow vs. higher-order dynamics approximations), model physics (e.g., representations of ice sheet rheological or basal processes), or model resolution (mesh resolution and/or changes in the spatial resolution of input datasets). The framework and metrics could also be used for use as a model-to-model intercomparison tool, simply by swapping outputs from another model as the observational datasets. Future versions of the tool will include comparisons with other datasets that are of interest to the modeling community, such as ice velocity, ice thickness, and surface mass balance.

  20. Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull

    International Nuclear Information System (INIS)

    Kang, Bok Hee; Kim, Kee Deog; Park, Chang Seo

    2001-01-01

    To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0 TM . One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired test was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % imcongruence were also performed. I-Gn, N-Gn, N-A, N-Ns, B-A and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient γ was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrb R and L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrb R and L respectively. It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which and difficult to be located

  1. Shoulder instability syndrome: comparison of CT, arthrography and MR findings

    International Nuclear Information System (INIS)

    Ortiz, L.; Alcaraz, M.; Preciados, J.L.G.; Garcia Alvarez, A.; Castello, J.

    1995-01-01

    Currently, the two most reliable explorations for diagnosing the lesions that produce shoulder instability are computerized tomography with arthrography and magnetic resonance following intraarticular injection of gadolinium. Dynamic CT arthrography is considered the best method to assess these lesions; MR is a similar procedure but involves certain drawbacks, among them, its cost. The techniques applied in these explorations are reviewed, as are the anatomy of the different components of this joint and the radiological findings leading to a diagnosis of the pathology underlying its instability. (Author)

  2. Comparison of 18-FDG PET and CT for pretherapeutic staging of malignant lymphoma

    International Nuclear Information System (INIS)

    Thill, R.; Cremerius, U.; Wagenknecht, G.; Hellwig, D.; Buell, U.; Neuerburg, J.; Guenther, R.; Fabry, U.; Osieka, R.

    1997-01-01

    Aim: Comparison of diagnostic efficiency of FDG-PET and CT regarding localisation, histology, size and FDG-uptake of a lesion. Methods: CT- and FDG-PET studies of 27 patients with histologically confirmed malignant lymphoma as primary disease or relapse were evaluated retrospectively. In CT lesions with a diameter (D CT )>15 mm were regarded as positive. Focal accumulations of FDG, not explained by physiological metabolism, found by visual interpretation in iterative reconstructed, PET-scans, were quantified for diameter (D PET ) and corrected standardized uptake value (SUV), corrected for partial-volume-effect. Lesions were classified depending on histology and lesion quality (lymph nodes, bulks, extranodal lesions). Results: CT detected 78 lesions in 26 patients, all confirmed by FDG-PET. PET localized 18 additional lesions (+23%); in high grade NHL +25%. Both methods were equally efficient in cevical lymph nodes and lung lesions, in all other regions of lymphatic nodules and in case of liver and spleen lesions PET localized more lesions. SUV was significantly higher in high-grade NHL (19.0) than in low-grade NHL and Hodgkin's disease (10.6 resp. 11.1). D CT and D PET correlated significantly (r=0.75). Conclusion: Diagnostic efficiency of FDG-PET is equivalent or superior to CT in staging of malignant lymphoma before therapy. Qualitative interpretation seems sufficient for staging, quantitative analysis may add information about malignancy grade in NHL. (orig.) [de

  3. Usefulness of MR imaging for diseases of the small intestine: comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hoon; Ha, Hyun Kwon; Sohn, Min Jae; Shin, Byung Suck; Lee, Young Suk; Chung, Soo Yoon; Kim, Pyo Nyun; Lee, Moon Gyu; Auh, Yong Ho [Ulsan University College of Medicine, Seoul (Korea, Republic of)

    2000-03-01

    To evaluate the usefulness of MR imaging for diseases of the small intestine, emphasizing a comparison with CT. Thirty-four patients who underwent both CT and MR imaging using FLASH 2D and HASTE sequences were analyzed. All patients had various small bowel diseases with variable association of peritoneal lesions. We compared the detectabilities of CT and MR imaging using different MR pulse sequences. The capability for analyzing the characteristics of small intestinal disease was also compared. MR imaging was nearly equal to CT for detecting intraluminal or peritoneal masses, lesions in the bowel and mesentery, and small bowel obstruction, but was definitely inferior for detecting omental lesions. The most successful MR imaging sequence was HASTE for demonstrating bowel wall thickening, coronal FLASH 2D for mesenteric lesions, and axial FLASH 2D for omental lesions. MR imaging yielded greater information than CT in six of 12 inflammatory bowel diseases, while it was equal to CT in six of seven neoplasms and inferior in five of seven mesenteric ischemia. In determining the primary causes of 15 intestinal obstructions, MR imaging was correct in 11 (73%) and CT in nine (60%) patients. MR imaging can serve as an alternative diagnostic tool for patients with suspected inflammatory bowel disease, small intestinal neoplasm or obstruction.

  4. Evaluation of the Meditech M250 and a comparison with other CT scanners

    Energy Technology Data Exchange (ETDEWEB)

    Greensmith, R.; Richardson, R.B.; Mackintosh, I.P.; Sargood, A.J.; Stevens, P.H.

    1985-11-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability.

  5. An evaluation of the Meditech M250 and a comparison with other CT scanners

    International Nuclear Information System (INIS)

    Greensmith, R.; Richardson, R.B.; Mackintosh, I.P.; Sargood, A.J.; Stevens, P.H.

    1985-01-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability. (author)

  6. An evaluation of the Meditech M250 and a comparison with other CT scanners.

    Science.gov (United States)

    Greensmith, R; Richardson, R B; Sargood, A J; Stevens, P H; Mackintosh, I P

    1985-11-01

    The Meditech M250 computerised tomography (CT) machine was evaluated during the first half of 1984. Measurements were made of noise, modulation transfer function, slice width, radiation dose profile, uniformity and linearity of CT number, effective photon energy and parameters relating to machine specification, such as pixel size and scan time. All breakdowns were logged to indicate machine reliability. A comparison with the established EMI CT1010 and CT5005 was made for noise, resolution and multislice radiation dose, as well as the dose efficiency or quality (Q) factor for both head and body modes of operation. The M250 was found to perform to its intended specification with an acceptable level of reliability.

  7. CT findings of pulmonary edema: comparison of various causes

    International Nuclear Information System (INIS)

    Kim, Hyae Young; Im, Jung Gi; Goo, Jin Mo; Lee, Jae Kyo; Song, Jae Woo

    1999-01-01

    To access the CT findings of pulmonary edema and to compare them, according to the cause. CT findings (thin section, 20 ; thick section, 16) of pulmonary edema in 36 patients [cardiac disease (group 1, n=20), renal disease (group 2, n=13), ARDS (group 3, n=3)] were analyzed and compared. There were 21 men and 15 women ranging in age from 27 to 77 years. Distribution (even, central, or peripheral) and patterns of pulmonary edema were compared between the three groups. The distribution of edema, appearing as consolidation or ground-glass opacity, was even in 75% (n=15) of group 1, even in 46% (n=6) and central in 38% (n=5) of group 2, and peripherally predominant in 100% (n=3) of group 3. Interlobular septal thickening was seen in 80% (n=16), 69% (n=9), and 0% of group 1, 2 and 3, respectively. Centrilobular ground-glass opacity was noted in six patients. In spite of various findings and considerable overlapping of the findings of pulmonary edema, the distribution and pattern of edema differed according to the cause, and this can be helpful for differential diagnosis

  8. Proton MRI appearance of cystic fibrosis: Comparison to CT

    International Nuclear Information System (INIS)

    Puderbach, Michael; Eichinger, Monika; Kauczor, Hans-Ulrich; Gahr, Julie; Mueller, Frank-Michael; Ley, Sebastian; Tuengerthal, Siegfried; Schmaehl, Astrid; Fink, Christian; Plathow, Christian; Wiebel, Matthias

    2007-01-01

    Cystic fibrosis (CF) is the most frequent inherited disorder leading to premature death in the Caucasian population. As life expectancy is limited by pulmonary complications, repeated imaging [chest X-ray, multislice high-resolution computed tomography (MS-HRCT)] is required in the follow-up. Magnetic resonance imaging (MRI) of the lung parenchyma is a promising new diagnostic tool. Its value for imaging lung changes caused by CF compared with CT is demonstrated. MRI performs well when compared with CT, which serves as the gold standard. Its lack in spatial resolution is obvious, but advantages in contrast and functional assessment compensate for this limitation. Thus, MRI is a reasonable alternative for imaging the CF lung and should be introduced as a radiation-free modality for follow-up studies in CF patients. For further evaluation of the impact of MRI, systematic studies comparing MRI and conventional imaging modalities are necessary. Furthermore, the value of the additional functional MRI (fMRI) information has to be studied, and a scoring system for the morphological and functional aspect of MRI has to be established. (orig.)

  9. Assess PET/MR in diagnosis of disease in comparison with PET/CT

    International Nuclear Information System (INIS)

    Yan, Jianhua; Lim, Jason Chu-Chern; Loi, Hoi Yin; Totoman, John; Sinha, Arvind Kumar; Quek, Swee Titan; Townsend, David

    2015-01-01

    The aim of this study is to assess the performance of 18F-FDG whole body PET/MRI in comparison with PET/CT based on SUV. Anatomical location of lesion with Dixon MRI and additional value of advanced MRI technology such as diffusion weighted MR imaging in diagnosis of malignant disease will also be investigated.

  10. Quantitative comparison of PET performance—Siemens Biograph mCT and mMR

    Energy Technology Data Exchange (ETDEWEB)

    Karlberg, Anna M.; Sæther, Oddbjørn [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Eikenes, Live [Department of Circulation and Medical Imaging, Norwegian University of Science and Technology, Postbox 8905, 7491 Trondheim (Norway); Goa, Pål Erik [Department of Radiology and Nuclear Medicine, St. Olavs Hospital, Olav Kyrres gt 17, 7006 Trondheim (Norway); Department of Physics, Norwegian University of Science and Technology, Trondheim (Norway)

    2016-02-25

    Integrated clinical whole-body PET/MR systems were introduced in 2010. In order to bring this technology into clinical usage, it is of great importance to compare the performance with the well-established PET/CT. The aim of this study was to evaluate PET performance, with focus on image quality, on Siemens Biograph mMR (PET/MR) and Siemens Biograph mCT (PET/CT). A direct quantitative comparison of the performance characteristics between the mMR and mCT system was performed according to National Electrical Manufacturers Association (NEMA) NU 2-2007 protocol. Spatial resolution, sensitivity, count rate and image quality were evaluated. The evaluation was supplemented with additional standardized uptake value (SUV) measurements. The spatial resolution was similar for the two systems. Average sensitivity was higher for the mMR (13.3 kcps/MBq) compared to the mCT system (10.0 kcps/MBq). Peak noise equivalent count rate (NECR) was slightly higher for the mMR (196 kcps @ 24.4 kBq/mL) compared to the mCT (186 kcps @ 30.1 kBq/mL). Scatter fractions in the clinical activity concentration range yielded lower values for the mCT (34.9 %) compared to those for the mMR (37.0 %). Best image quality of the systems resulted in approximately the same mean hot sphere contrast and a difference of 19 percentage points (pp) in mean cold contrast, in favour of the mCT. In general, point spread function (PSF) increased hot contrast and time of flight (TOF) increased both hot and cold contrast. Highest hot contrast for the smallest sphere (10 mm) was achieved with the combination of TOF and PSF on the mCT. Lung residual error was higher for the mMR (22 %) than that for the mCT (17 %), with no effect of PSF. With TOF, lung residual error was reduced to 8 % (mCT). SUV was accurate for both systems, but PSF caused overestimations for the 13-, 17- and 22-mm spheres. Both systems proved good performance characteristics, and the PET image quality of the mMR was close to that of the mCT

  11. Comparison of radiography, CT and MR imaging in detection of arthropathies in patients with hemophilia

    International Nuclear Information System (INIS)

    Yu Wei; Lin Qiang; Shang Wei; Zhu Haifeng; Meng Wei; Xu Ruiyi; Zhao Yongqiang; Shi Yongsheng

    2007-01-01

    Objective: To compare MR, CT, and radiography in the detection of arthropathies in patients with hemophilia. Methods: Forty-one symptomic joint images in the 14 patients with hemophilia, aged from 11 to 24 years, were used in this study. Each joint had the examinations of radiography, CT and MR within one day. The severity of each joint was staged using conventional radiographic classification. Severe HA patients with stage 5 were excluded from the study. Imaging findings of soft tissue swelling, osteoporosis, epiphyseal overgrowth, joint erosion, cyst, joint space narrowing, bone marrow, joint effusion, hemorrhage, synovial hypertrophy, widened intercondylar notch as well as anterior and posterior cruciate ligaments (only for knee joint) were used for the all imaging comparison. Results: The 41 symptomatic joints in 14 patients with hemophilia were classified by radiographic criteria into stage 0 (n=5), stage 1 (n=7), stage 2 (n=6), stage 3 (n=8) and stage 4 (n=15). Soft tissue swelling or joint effusion was observed in 33 joints by radiographs, in 34 joints by both CT and MR. Joint erosions were demonstrated in 34 joints by MR, in 33 joints by CT and 20 joints by radiographs. Joint cysts were shown in 21 joints by MR, in 18 joints by CT and 9 joints by radiographs. Significant differences in detection of erosion and cyst were found between radiography with either CT (P 0.05). MR showed improvement for detecting more foci of both erosion and cyst than CT and radiography, and also CT showed the improvement than radiography. Bone marrow edema 14 joints, hemorrhage in 34 joints and synovial hypertrophy in 27 joints were revealed on MR images. Conclusion: MRI is superior to CT and conventional radiography in detecting the abnormal changes and should be considered as the first choice among the imaging modalities in evaluating hemophilic arthropathies. (authors)

  12. Computed tomographic colonography to screen for colorectal cancer, extracolonic cancer, and aortic aneurysm: model simulation with cost-effectiveness analysis.

    Science.gov (United States)

    Hassan, Cesare; Pickhardt, Perry J; Pickhardt, Perry; Laghi, Andrea; Kim, Daniel H; Kim, Daniel; Zullo, Angelo; Iafrate, Franco; Di Giulio, Lorenzo; Morini, Sergio

    2008-04-14

    In addition to detecting colorectal neoplasia, abdominal computed tomography (CT) with colonography technique (CTC) can also detect unsuspected extracolonic cancers and abdominal aortic aneurysms (AAA).The efficacy and cost-effectiveness of this combined abdominal CT screening strategy are unknown. A computerized Markov model was constructed to simulate the occurrence of colorectal neoplasia, extracolonic malignant neoplasm, and AAA in a hypothetical cohort of 100,000 subjects from the United States who were 50 years of age. Simulated screening with CTC, using a 6-mm polyp size threshold for reporting, was compared with a competing model of optical colonoscopy (OC), both without and with abdominal ultrasonography for AAA detection (OC-US strategy). In the simulated population, CTC was the dominant screening strategy, gaining an additional 1458 and 462 life-years compared with the OC and OC-US strategies and being less costly, with a savings of $266 and $449 per person, respectively. The additional gains for CTC were largely due to a decrease in AAA-related deaths, whereas the modeled benefit from extracolonic cancer downstaging was a relatively minor factor. At sensitivity analysis, OC-US became more cost-effective only when the CTC sensitivity for large polyps dropped to 61% or when broad variations of costs were simulated, such as an increase in CTC cost from $814 to $1300 or a decrease in OC cost from $1100 to $500. With the OC-US approach, suboptimal compliance had a strong negative influence on efficacy and cost-effectiveness. The estimated mortality from CT-induced cancer was less than estimated colonoscopy-related mortality (8 vs 22 deaths), both of which were minor compared with the positive benefit from screening. When detection of extracolonic findings such as AAA and extracolonic cancer are considered in addition to colorectal neoplasia in our model simulation, CT colonography is a dominant screening strategy (ie, more clinically effective and more cost

  13. CT hepatic perfusion measurement: Comparison of three analytic methods

    International Nuclear Information System (INIS)

    Kanda, Tomonori; Yoshikawa, Takeshi; Ohno, Yoshiharu; Kanata, Naoki; Koyama, Hisanobu; Takenaka, Daisuke; Sugimura, Kazuro

    2012-01-01

    Objectives: To compare the efficacy of three analytic methods, maximum slope (MS), dual-input single-compartment model (CM) and deconvolution (DC), for CT measurements of hepatic perfusion and assess the effects of extra-hepatic systemic factors. Materials and methods: Eighty-eight patients who were suspected of having metastatic liver tumors underwent hepatic CT perfusion. The scans were performed at the hepatic hilum 7–77 s after administration of contrast material. Hepatic arterial and portal perfusions (HAP and HPP, ml/min/100 ml) and arterial perfusion fraction (APF, %) were calculated with the three methods, followed by correlation assessment. Partial correlation analysis was used to assess the effects on hepatic perfusion values by various factors such as age, sex, risk of cardiovascular diseases, arrival time of contrast material at abdominal aorta, transit time from abdominal aorta to hepatic parenchyma, and liver dysfunction. Results: Mean HAP of MS was significantly higher than DC. HPP of CM was significantly higher than MS and CM, and HPP of MS was significantly higher than DC. There was no significant difference in APF. HAP and APF showed significant and moderate correlations among the methods. HPP showed significant and moderate correlations between CM and DC, and poor correlation between MS and CM or DC. All methods showed weak correlations between HAP or APF and age or sex. Finally, MS showed weak correlations between HAP or HPP and arrival time or cardiovascular risks. Conclusions: Hepatic perfusion values arrived at with the three methods are not interchangeable. CM and DC are less susceptible to extra-hepatic systemic factors

  14. Computed tomography colonography versus colonoscopy for the diagnosis of colorectal cancer: a systematic review and meta-analysis

    Directory of Open Access Journals (Sweden)

    Duarte RB

    2018-02-01

    Full Text Available Ralph B Duarte, Wanderley M Bernardo, Christiano M Sakai, Gustavo LR Silva, Hugo G Guedes, Rogerio Kuga, Edson Ide, Robson K Ishida, Paulo Sakai, Eduardo GH de Moura Gastrointestinal Endoscopy Unit of Hospital das Clínicas of São Paulo University Medical School, São Paulo, SP, Brazil Abstract: Colorectal cancer (CRC is a significant cause of morbidity and mortality. Optical colonoscopy (OC is the first choice of investigation for assessing the state of the colon and it is excellent for CRC screening. Newer technologies such as computed tomography colonography (CTC may also be useful in CRC screening. This systematic review compares the benefits of CTC and OC for CRC screening. This review includes all the available randomized clinical trials comparing CTC and OC for CRC screening in asymptomatic patients. Three studies were included in the systematic review and were submitted for meta-analysis. In the analysis of participation rates, only 2,333 of 8,104 (29% patients who were invited for screening underwent the CTC, and only 1,486 of the 7,310 (20% patients who were invited for screening underwent OC. The absolute risk difference in participation rate in the two procedures was 0.1 (95% CI, 0.05–0.14 in favor of CTC. In the analysis of advanced colorectal neoplasia (ACN detection rates, 2,357 patients undergoing CTC and 1,524 patients undergoing OC were included. Of these, 135 patients (5.7% who underwent a CTC and 130 patients (8.5% who underwent an OC were diagnosed with ACN. The absolute risk difference in ACN detection rate in the two procedure types was -0.02 (with a 95% CI between -0.04 and -0.00 in favor of OC. CTC is an option for CRC screening in asymptomatic patients. However, as CTC was inferior in detecting ACN, it should not replace OC, which remains the gold standard. Keywords: computed tomography colonography, colonography, CT colonography, virtual colonoscopy, colonoscopy, colorectal neoplasm, colorectal cancer, colorectal

  15. Comparison of positron emission tomography/CT and bremsstrahlung imaging following Y-90 radiation synovectomy

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Yap, Kenneth S.K.; Cherk, Martin H.; Kalff, Victor; Powell, Anne

    2013-01-01

    The aim of this study is to compare the results of positron emission tomography (PET)/CT with bremsstrahlung imaging following Y-90 radiation synovectomy. All patients referred to our institution for Y-90 radiation synovectomy between July 2011 and February 2012 underwent both PET/CT and bremsstrahlung planar (±single photon emission computed tomography (SPECT) or SPECT/CT) imaging at 4 or 24 h following administration of Y-90 silicate colloid. PET image acquisition was performed for between 15 and 20min. In patients who underwent SPECT, side-by-side comparison with PET was performed and image quality/resolution scored using a five-point scale. The distribution pattern of Y-90 on PET and bremsstrahlung imaging was compared with the intra- or extra-articular location of Y-90 activity on fused PET/CT. Thirteen joints (11 knees and two ankles) were imaged with both PET/CT and planar bremsstrahlung imaging with 12 joints also imaged with bremsstrahlung SPECT. Of the 12 joints imaged with SPECT, PET image quality/resolution was superior in 11 and inferior in one. PET demonstrated a concordant distribution pattern compared with bremsstrahlung imaging in all scans, with the pattern classified as diffuse in 12 and predominantly focal in one. In all 12 diffuse scans, PET/CT confirmed the Y-90 activity to be located intra-articularly. In the one predominantly focal scan, the fused PET/CT images localised the Y-90 activity to mostly lie in the extra-articular space of the knee. PET/CT can provide superior image quality compared with bremsstrahlung imaging and may enable reliable detection of extra-articular Y-90 activity when there are focal patterns on planar bremsstrahlung imaging.

  16. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  17. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  18. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  19. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T. [University Hospital Zurich, Department of Medical Radiology, Zurich (Switzerland)

    2013-01-15

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body {sup 18}F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  20. Discrimination and anatomical mapping of PET-positive lesions: comparison of CT attenuation-corrected PET images with coregistered MR and CT images in the abdomen

    International Nuclear Information System (INIS)

    Kuhn, Felix P.; Crook, David W.; Mader, Caecilia E.; Appenzeller, Philippe; Schulthess, G.K. von; Schmid, Daniel T.

    2013-01-01

    PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. A total of 100 oncological patients underwent sequential whole-body 18 F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust. (orig.)

  1. Direct comparison of [18F]FDG PET/CT with PET alone and with side-by-side PET and CT in patients with malignant melanoma

    International Nuclear Information System (INIS)

    Mottaghy, Felix M.; Wohlfart, Petra; Blumstein, Norbert M.; Neumaier, Bernd; Glatting, Gerhard; Buck, Andreas K.; Reske, Sven N.; Sunderkoetter, Cord; Schubert, Roland; Oezdemir, Cueneyt; Scharfetter-Kochanek, Karin

    2007-01-01

    The purpose of this retrospective, blinded study was to evaluate the additional value of [ 18 F]FDG PET/CT in comparison with PET alone and with side-by-side PET and CT in patients with malignant melanoma (MM). A total of 127 consecutive studies of patients with known MM referred for a whole-body PET/CT examination were included in this study. PET alone, side-by-side PET and CT and integrated PET/CT study were independently and separately interpreted without awareness of the clinical information. One score each was applied for certainty of lesion localisation and for certainty of lesion characterisation. Verification of the findings was subsequently performed using all available clinical, pathological (n = 30) and follow-up information. The number of lesions with an uncertain localisation was significantly (p 18 F]FDG. (orig.)

  2. A comparison of linear interpolation models for iterative CT reconstruction.

    Science.gov (United States)

    Hahn, Katharina; Schöndube, Harald; Stierstorfer, Karl; Hornegger, Joachim; Noo, Frédéric

    2016-12-01

    Recent reports indicate that model-based iterative reconstruction methods may improve image quality in computed tomography (CT). One difficulty with these methods is the number of options available to implement them, including the selection of the forward projection model and the penalty term. Currently, the literature is fairly scarce in terms of guidance regarding this selection step, whereas these options impact image quality. Here, the authors investigate the merits of three forward projection models that rely on linear interpolation: the distance-driven method, Joseph's method, and the bilinear method. The authors' selection is motivated by three factors: (1) in CT, linear interpolation is often seen as a suitable trade-off between discretization errors and computational cost, (2) the first two methods are popular with manufacturers, and (3) the third method enables assessing the importance of a key assumption in the other methods. One approach to evaluate forward projection models is to inspect their effect on discretized images, as well as the effect of their transpose on data sets, but significance of such studies is unclear since the matrix and its transpose are always jointly used in iterative reconstruction. Another approach is to investigate the models in the context they are used, i.e., together with statistical weights and a penalty term. Unfortunately, this approach requires the selection of a preferred objective function and does not provide clear information on features that are intrinsic to the model. The authors adopted the following two-stage methodology. First, the authors analyze images that progressively include components of the singular value decomposition of the model in a reconstructed image without statistical weights and penalty term. Next, the authors examine the impact of weights and penalty on observed differences. Image quality metrics were investigated for 16 different fan-beam imaging scenarios that enabled probing various aspects

  3. A comparison of iopamidol and ioxaglate in CT enhancement

    International Nuclear Information System (INIS)

    Del Favero, C.; Rossini, G.; Martegani, A.

    1993-01-01

    We evaluated the adverse reactions (AR) rate produced in patients to see if any difference, related to the different chemotoxicities of two low-osmolality contrast media (CM), could be detected. We compared the AR rate after intravenous administration for brain or body computed tomography (CT) enhancement of either the ionic CM ioxaglate 320 mgI/ml or the non-ionic iopamidol 300 mgI/ml at a dose of 0.8 gI/kg. Three hundred and thirty patients (164 ioxaglate, 166 iopamidol) were studied according to a randomized double-blind design. AR reported by the patient (subjective) and/or observed by the radiologist (objective) were recorded by the radiologist on the patient record card. Laboratory tests were performed prior to and 24 h after contrast administration. Fifty-nine mild to moderate AR occurred in 30 patients (18.3%) receiving ioxaglate, 4 mild to moderate AR occurred in 2 patients (1.2%) receiving iopamidol (P < 0.05). No severe AR occurred in either group. The results of our study are comparable to the available evidence from 16 comparative randomized trials of iopamidol versus ioxaglate both after intraarterial and intravenous administration that gave an overall odds ratio of 3.9 [confidence interval (CI) 95%=3.1-4.9]. The diagnostic efficacy of the two CM was comparable. This study showed that the non-ionic CM iopamidol was better tolerated than the ionic ioxaglate after intravenous administration. We conclude that the chemotoxicity of the molecule influences the AR when CM with comparable osmolality are administered. (orig.)

  4. Restaging of patients with lymphoma. Comparison of low dose CT (20 mAs) with contrast enhanced diagnostic CT in combined [18F]-FDG PET/CT

    International Nuclear Information System (INIS)

    Fougere, C. la; Pfluger, T.; Schneider, V.; Hacker, M.; Broeckel, N.; Bartenstein, P.; Tiling, R.; Morhard, D.; Hundt, W.; Becker, C.

    2008-01-01

    Aim: assessment of the clinical benefit of i.v. contrast enhanced diagnostic CT (CE-CT) compared to low dose CT with 20 mAs (LD-CT) without contrast medium in combined [ 18 F]-FDG PET/CT examinations in restaging of patients with lymphoma. Patients, methods: 45 patients with non-Hodgkin lymphoma (n = 35) and Hodgkin's disease (n = 10) were included into this study. PET, LD-CT and CE-CT were analyzed separately as well as side-by-side. Lymphoma involvement was evaluated separately for seven regions. Indeterminate diagnoses were accepted whenever there was a discrepancy between PET and CT findings. Results for combined reading were calculated by rating indeterminate diagnoses according the suggestions of either CT or PET. Each patient had a clinical follow-up evaluation for > 6 months. Results: region-based evaluation suggested a sensitivity/specificity of 66/93% for LD-CT, 87%/91% for CE-CT, 95%/96% for PET, 94%/99% for PET/LD-CT and 96%/99% for PET/CE-CT. The data for PET/CT were obtained by rating indeterminate results according to the suggestions of PET, which turned out to be superior to CT. Lymphoma staging was changed in two patients using PET/CE-CT as compared to PET/LD-CT. Conclusion: overall, there was no significant difference between PET/LD-CT and PET/CE-CT. However, PET/CE-CT yielded a more precise lesion delineation than PET/LD-CT. This was due to the improved image quality of CE-CT and might lead to a more accurate investigation of lymphoma. (orig.)

  5. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    Energy Technology Data Exchange (ETDEWEB)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-02-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author).

  6. Comparison between air CT and MRI in the detection of small acoustic neurinomas

    International Nuclear Information System (INIS)

    Kamei, Tetsuya; Nakashima, Aiko; Seto, Hikaru; Kakishita, Masao

    1989-01-01

    Air CT proved useful in yielding images of acoustic tumors as an air filling defect in 11 (24%) of 46 patients. Six of the 11 tumors were small ones of less than 1 cm in diameter. Air CT was also able to exclude an intracanalicular tumor in 29 patients (63%). MRI was performed for comparison in eight patients (nine tumors) already diagnosed by air CT as having an acoustic tumor. MRI detected eight (89%) of nine tumors. A false negative result on MRI was obtained only in one intracanalicular tumor (4.3 mm in size). This was considered to be attributable to limitations of spatial resolution including the wide slice thickness. A protocol for radiological investigation and management of patients whose clinical symptoms and/or audiovestibular examination are highly indicative of acoustic tumor is proposed and discussed. (author)

  7. Additional value of PET-CT in the staging of lung cancer: comparison with CT alone, PET alone and visual correlation of PET and CT

    International Nuclear Information System (INIS)

    Wever, W. de; Marchal, G.; Bogaert, J.; Verschakelen, J.A.; Ceyssens, S.; Mortelmans, L.; Stroobants, S.

    2007-01-01

    Integrated positron emission tomography (PET) and computed tomography (CT) is a new imaging modality offering anatomic and metabolic information. The purpose was to evaluate retrospectively the accuracy of integrated PET-CT in the staging of a suggestive lung lesion, comparing this with the accuracy of CT alone, PET alone and visually correlated PET-CT. Fifty patients undergoing integrated PET-CT for staging of a suggestive lung lesion were studied. Their tumor, node, metastasis (TNM) statuses were determined with CT, PET, visually correlated PET-CT and integrated PET-CT. These TNM stages were compared with the surgical TNM status. Integrated PET-CT was the most accurate imaging technique in the assessment of the TNM status. Integrated PET-CT predicted correctly the T status, N status, M status and TNM status in, respectively, 86%, 80%, 98%, 70% versus 68%, 66%,88%, 46% with CT, 46%, 70%, 96%, 30% with PET and 72%, 68%, 96%, 54% with visually correlated PET-CT. T status and N status were overstaged, respectively, in 8% and 16% with integrated PET-CT, in 20% and 28% with CT, in 16% and 20% with PET, in 12% and 20% with visually correlated PET-CT and understaged in 6% and 4% with integrated PET-CT, versus 12% and 6% with CT, 38% and 10% with PET and 12% with visually correlated PET-CT. Integrated PET-CT improves the staging of lung cancer through a better anatomic localization and characterization of lesions and is superior to CT alone and PET alone. If this technique is not available, visual correlation of PET and CT can be a valuable alternative. (orig.)

  8. Comparison of SPECT/CT, MRI and CT in diagnosis of skull base bone invasion in nasopharyngeal carcinoma.

    Science.gov (United States)

    Zhang, Shu-xu; Han, Peng-hui; Zhang, Guo-qian; Wang, Rui-hao; Ge, Yong-bin; Ren, Zhi-gang; Li, Jian-sheng; Fu, Wen-hai

    2014-01-01

    Early detection of skull base invasion in nasopharyngeal carcinoma (NPC) is crucial for correct staging, assessing treatment response and contouring the tumor target in radiotherapy planning, as well as improving the patient's prognosis. To compare the diagnostic efficacy of single photon emission computed tomography/computed tomography (SPECT/CT) imaging, magnetic resonance imaging (MRI) and computed tomography (CT) for the detection of skull base invasion in NPC. Sixty untreated patients with histologically proven NPC underwent SPECT/CT imaging, contrast-enhanced MRI and CT. Of the 60 patients, 30 had skull base invasion confirmed by the final results of contrast-enhanced MRI, CT and six-month follow-up imaging (MRI and CT). The diagnostic efficacy of the three imaging modalities in detecting skull base invasion was evaluated. The rates of positive findings of skull base invasion for SPECT/CT, MRI and CT were 53.3%, 48.3% and 33.3%, respectively. The sensitivity, specificity and accuracy were 93.3%, 86.7% and 90.0% for SPECT/CT fusion imaging, 96.7%, 100.0% and 98.3% for contrast-enhanced MRI, and 66.7%, 100.0% and 83.3% for contrast-enhanced CT. MRI showed the best performance for the diagnosis of skull base invasion in nasopharyngeal carcinoma, followed closely by SPECT/CT. SPECT/CT had poorer specificity than that of both MRI and CT, while CT had the lowest sensitivity.

  9. Magnetic resonance colonography versus colonoscopy as a diagnostic investigation for colorectal cancer: a meta-analysis

    International Nuclear Information System (INIS)

    Purkayastha, S.; Tekkis, P.P.; Athanasiou, T.; Aziz, O.; Negus, R.; Gedroyc, W.; Darzi, A.W.

    2005-01-01

    AIMS: Magnetic resonance colonography (MRC) is emerging as a potential complementary investigation for the diagnosis of colorectal cancer (CRC) and also for benign pathology such as diverticular disease. A meta-analysis reporting the use of MRC is yet to be performed. The aim of this study was to evaluate the diagnostic accuracy of MRC compared with the gold-standard investigation, conventional colonoscopy (CC). METHODS: A literature search was carried out to identify studies containing comparative data between MRC findings and CC findings. Quantitative meta-analysis for diagnostic tests was performed, which included the calculation of independent sensitivities, specificities, diagnostic odds ratios, the construction of summary receiver operating characteristic (SROC) curves, pooled analysis and sensitivity analysis. The study heterogeneity was evaluated by the Q-test using a random-effect model to accommodate the cluster of outcomes between individual studies. RESULTS: In all, 8 comparative studies were identified, involving 563 patients. The calculated pooled sensitivity for all lesions was 75% (95% CI: 47% to 91%), the specificity was 96% (95% CI: 86% to 98%) and the area under the ROC curve was 90% (weighted). On sensitivity analysis, MRC had a better diagnostic accuracy for CRC than for polyps, with a sensitivity of 91% (95% CI: 97% to 91%), a specificity of 98% (95% CI: 66% to 99%) and an area under the ROC curve of 92%. There was no significant heterogeneity between the studies with regard to the diagnostic accuracy of MRC for CRC. CONCLUSION: This meta-analysis suggests that MRC is an imaging technique with high discrimination for cases presenting with colorectal cancer. The exact diagnostic role of MRC needs to be clarified (e.g. suitable for an elderly person with suspected CRC). Further evaluation is necessary to refine its applicability and diagnostic accuracy in comparison with other imaging methods such as computed tomography colonography

  10. CT-based postimplant dosimetry of prostate brachytherapy. Comparison of 1-mm and 5-mm section CT

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Kanematsu, Masayuki; Matsuo, Masayuki; Hoshi, Hiroaki; Nakano, Masahiro; Maeda, Sanaho; Deguchi, Takashi; Hoshi, Hiroaki

    2007-01-01

    The aim of this study was to compare the outcomes between 1-mm and 5-mm section computed tomography (CT)-based postimplant dosimetry. A series of 21 consecutive patients underwent permanent prostate brachytherapy. The postimplant prostate volume was calculated using 1-mm and 5-mm section CT. One radiation oncologist contoured the prostate on CT images to obtain the reconstructed prostate volume (pVol), prostate V 100 (percent of the prostate volume receiving at least the full prescribed dose), and prostate D 90 (mean dose delivered to 90% of the prostate gland). The same radiation oncologist performed the contouring three times to evaluate intraobserver variation and subjectively scored the quality of the CT images. The mean ±1 standard deviation (SD) postimplant pVol was 20.17±6.66 cc by 1-mm section CT and 22.24±8.48 cc by 5-mm section CT; the difference in the mean values was 2.06 cc (P 100 was 80.44%±7.06% by 1-mm section CT and 77.33%±10.22% by 5-mm section CT. The mean postimplant prostate D 90 was 83.28%±10.81% by 1-mm section CT and 78.60%±15.75% by 5-mm section CT. In the evaluation of image quality, 5-mm section CT was assigned significantly higher scores than 1-mm section CT. In regard to intraobserver variation, 5-mm section CT revealed less intraobserver variation than 1-mm section CT. Our current results suggested that the outcomes of postimplant dosimetry using 1-mm section CT did not improved the results over those obtained using 5-mm section CT in terms of the quality of the CT image or reproducibility. (author)

  11. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  12. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias; Scholz, Bernhard; Royalty, Kevin

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  13. Enhanced CT in the diagnosis of acute appendicitis to evaluate the severity of disease. Comparison of CT findings and histological diagnosis

    International Nuclear Information System (INIS)

    Mori, Yoshiko; Yamasaki, Michio; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2001-01-01

    To assess the potential of CT in evaluating the histological severity of acute appendicitis in comparison with surgical and pathological findings. The CT images of 75 patients with surgically proven appendicitis, including 10 cases of catarrhal, 34 of phlegmonous, and 31 of gangrenous appendicitis, were retrospectively analyzed for the following five CT findings: hazy periappendiceal densities, enlarged appendix, increased enhancement of the appendiceal wall, increased enhancement of the periappendiceal intestinal wall, and deficiency of the appendiceal wall. By comparing all the CT findings and the pathological severity of appendicitis (catarrhal, phlegmonous, and gangrenous), the prevalence of the five CT findings was calculated for each pathological category. Abnormal CT findings were noted in only one case of catarrhal appendicitis. Increased enhancement of the appendiceal wall was observed in all 29 cases of phlegmonous appendicitis (100%), but in only 66.7% (18 cases) of gangrenous appendicitis. Deficiency of the appendiceal wall was more frequently observed in gangrenous (19/27, 70.4%) than phlegmonous appendicitis (4/29, 13.8%). Findings of enhanced CT provide useful information in evaluating the pathological severity of acute appendicitis. (author)

  14. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  15. Accuracy of low dose CT in the diagnosis of appendicitis in childhood and comparison with USG and standard dose CT.

    Science.gov (United States)

    Yi, Dae Yong; Lee, Kyung Hoon; Park, Sung Bin; Kim, Jee Taek; Lee, Na Mi; Kim, Hyery; Yun, Sin Weon; Chae, Soo Ahn; Lim, In Seok

    Computed tomography should be performed after careful consideration due to radiation hazard, which is why interest in low dose CT has increased recently in acute appendicitis. Previous studies have been performed in adult and adolescents populations, but no studies have reported on the efficacy of using low-dose CT in children younger than 10 years. Patients (n=475) younger than 10 years who were examined for acute appendicitis were recruited. Subjects were divided into three groups according to the examinations performed: low-dose CT, ultrasonography, and standard-dose CT. Subjects were categorized according to age and body mass index (BMI). Low-dose CT was a contributive tool in diagnosing appendicitis, and it was an adequate method, when compared with ultrasonography and standard-dose CT in terms of sensitivity (95.5% vs. 95.0% and 94.5%, p=0.794), specificity (94.9% vs. 80.0% and 98.8%, p=0.024), positive-predictive value (96.4% vs. 92.7% and 97.2%, p=0.019), and negative-predictive value (93.7% vs. 85.7% and 91.3%, p=0.890). Low-dose CT accurately diagnosed patients with a perforated appendix. Acute appendicitis was effectively diagnosed using low-dose CT in both early and middle childhood. BMI did not influence the accuracy of detecting acute appendicitis on low-dose CT. Low-dose CT is effective and accurate for diagnosing acute appendicitis in childhood, as well as in adolescents and young adults. Additionally, low-dose CT was relatively accurate, irrespective of age or BMI, for detecting acute appendicitis. Therefore, low-dose CT is recommended for assessing children with suspected acute appendicitis. Copyright © 2017. Published by Elsevier Editora Ltda.

  16. Closing in on the K Edge : Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System

    NARCIS (Netherlands)

    Meyer, Mathias; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, Thomas

    2014-01-01

    Purpose: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. Materials and Methods: All

  17. Initial experience with computed tomographic colonography applied for noncolorectal cancerous conditions

    International Nuclear Information System (INIS)

    Ichikawa, Tamaki; Kawada, Shuichi; Hirata, Satoru; Ikeda, Shu; Sato, Yuuki; Imai, Yutaka

    2011-01-01

    The aim of this study was to asses retrospectively the performance of computed tomography colonography (CTC) for noncolorectal cancerous conditions. A total of 44 patients with non-colorectal cancerous conditions underwent CTC. We researched the indications for CTC or present illness and evaluated the CTC imaging findings. We assessed whether diagnosis by CTC reduced conventional colonoscopic examinations. A total of 47 examinations were performed in 44 patients. The indications for CTC or a present illness were as follows: 15 patients with impossible or incomplete colonoscopy, 7 with diverticular disease, 6 with malignancy (noncolorectal cancer), 6 with Crohn's disease, 4 suspected to have a submucosal tumor on colonoscopy, 2 with ischemic colitis, and 4 with various other diseases. Colonic findings were diagnosed on CTC in 36 examinations, and extracolonic findings were identified in 35 of 44 patients. In all, 17 patients had undergone colonoscopy previously, 9 (52.9%) of whom did not require further colonoscopy by CTC. Five patients underwent colonoscopy after CTC. The indications for CTC were varied for patients with noncolorectal cancerous conditions. CTC examinations could be performed safely. Unlike colonoscopy or CT without preparation, CTC revealed colonic and extracolonic findings and may reduce the indication of colonoscopy in patients with noncolorectal cancerous conditions. (author)

  18. Emphysema quantification and lung volumetry in chest X-ray equivalent ultralow dose CT - Intra-individual comparison with standard dose CT.

    Science.gov (United States)

    Messerli, Michael; Ottilinger, Thorsten; Warschkow, René; Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Bauer, Ralf W

    2017-06-01

    To determine whether ultralow dose chest CT with tin filtration can be used for emphysema quantification and lung volumetry and to assess differences in emphysema measurements and lung volume between standard dose and ultralow dose CT scans using advanced modeled iterative reconstruction (ADMIRE). 84 consecutive patients from a prospective, IRB-approved single-center study were included and underwent clinically indicated standard dose chest CT (1.7±0.6mSv) and additional single-energy ultralow dose CT (0.14±0.01mSv) at 100kV and fixed tube current at 70mAs with tin filtration in the same session. Forty of the 84 patients (48%) had no emphysema, 44 (52%) had emphysema. One radiologist performed fully automated software-based pulmonary emphysema quantification and lung volumetry of standard and ultralow dose CT with different levels of ADMIRE. Friedman test and Wilcoxon rank sum test were used for multiple comparison of emphysema and lung volume. Lung volumes were compared using the concordance correlation coefficient. The median low-attenuation areas (LAA) using filtered back projection (FBP) in standard dose was 4.4% and decreased to 2.6%, 2.1% and 1.8% using ADMIRE 3, 4, and 5, respectively. The median values of LAA in ultralow dose CT were 5.7%, 4.1% and 2.4% for ADMIRE 3, 4, and 5, respectively. There was no statistically significant difference between LAA in standard dose CT using FBP and ultralow dose using ADMIRE 4 (p=0.358) as well as in standard dose CT using ADMIRE 3 and ultralow dose using ADMIRE 5 (p=0.966). In comparison with standard dose FBP the concordance correlation coefficients of lung volumetry were 1.000, 0.999, and 0.999 for ADMIRE 3, 4, and 5 in standard dose, and 0.972 for ADMIRE 3, 4 and 5 in ultralow dose CT. Ultralow dose CT at chest X-ray equivalent dose levels allows for lung volumetry as well as detection and quantification of emphysema. However, longitudinal emphysema analyses should be performed with the same scan protocol and

  19. Comparison of MRI-based and CT/MRI fusion-based postimplant dosimetric analysis of prostate brachytherapy

    International Nuclear Information System (INIS)

    Tanaka, Osamu; Hayashi, Shinya; Matsuo, Masayuki; Sakurai, Kota; Nakano, Masahiro; Maeda, Sunaho; Kajita, Kimihiro R.T.; Deguchi, Takashi; Hoshi, Hiroaki

    2006-01-01

    Purpose: The aim of this study was to compare the outcomes between magnetic resonance imaging (MRI)-based and computed tomography (CT)/MRI fusion-based postimplant dosimetry methods in permanent prostate brachytherapy. Methods and Materials: Between October 2004 and March 2006, a total of 52 consecutive patients with prostate cancer were treated by brachytherapy, and postimplant dosimetry was performed using CT/MRI fusion. The accuracy and reproducibility were prospectively compared between MRI-based dosimetry and CT/MRI fusion-based dosimetry based on the dose-volume histogram (DVH) related parameters as recommended by the American Brachytherapy Society. Results: The prostate volume was 15.97 ± 6.17 cc (mean ± SD) in MRI-based dosimetry, and 15.97 ± 6.02 cc in CT/MRI fusion-based dosimetry without statistical difference. The prostate V100 was 94.5% and 93.0% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.002). The prostate D90 was 119.4% and 114.4% in MRI-based and CT/MRI fusion-based dosimetry, respectively, and the difference was statistically significant (p = 0.004). Conclusion: Our current results suggested that, as with fusion images, MR images allowed accurate contouring of the organs, but they tended to overestimate the analysis of postimplant dosimetry in comparison to CT/MRI fusion images. Although this MRI-based dosimetric discrepancy was negligible, MRI-based dosimetry was acceptable and reproducible in comparison to CT-based dosimetry, because the difference between MRI-based and CT/MRI fusion-based results was smaller than that between CT-based and CT/MRI fusion-based results as previously reported

  20. Pulmonary langerhans cell histiocytosis in adults: high-resolution CT - pathology comparisons and evolutional changes at CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyo Jin; Lee, Ho Yun; Kim, Tae Sung [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Lee, Kyung Soo [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Samsung Medical Center, Department of Radiology, Seoul (Korea, Republic of); Johkoh, Takeshi [Kinki Central Hospital of Mutual Aid Association of Public School Teachers, Department of Radiology, Hyoko (Japan); Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Radiology, Osaka (Japan); Han, Joungho [Sungkyunkwan University School of Medicine, Department of Pathology, Samsung Medical Center, Seoul (Korea, Republic of)

    2011-07-15

    To compare high-resolution (HR) CT and histopathological findings and to evaluate serial CT findings in pulmonary Langerhans cell histiocytosis (PLCH). We reviewed CT of lung lesions in 27 adults (M:F = 20:7, mean age, 41 {+-} 12.3 years) with PLCH. After evaluating lung abnormalities including nodules, micronodules, thick-walled, thin-walled, and bizarre-shaped cysts and reticulation, observers compared CT findings obtained at lung biopsy sites with histopathological findings. The final CT was compared with the initial CT to determine disease extent changes. The most frequently observed patterns of lung abnormalities were micronodules (n = 24, 89%), thick-walled (n = 22, 82%), and thin-walled (n = 22, 82%) cysts. Even thin-walled and bizarre cysts harboured active inflammatory Langerhans cell sheets and eosinophils in their walls. In thin-walled cysts, we noted pericystic inflammatory cell infiltrations along the alveolar walls, as well as pericystic emphysema. Thin-walled or bizarre cysts demonstrated a tendency to coalesce with surrounding cysts via their cystic wall destruction. Fourteen (52%) patients showed improvement and nine (33%) showed progressing disease. More than half of patients with pulmonary PLCH show improvement at follow-up CT. Even thin-walled cysts harbour active inflammatory cells on histopathology and exhibit improvement at follow-up CT. (orig.)

  1. Comparison of the 68Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT in the Evaluation of Suspected Primary Pheochromocytomas and Paragangliomas.

    Science.gov (United States)

    Jing, Hongli; Li, Fang; Wang, Ling; Wang, Zhenghua; Li, Wei; Huo, Li; Zhang, Jingjing

    2017-07-01

    Anatomical imaging modalities including CT and MRI are the mainstay of evaluation of primary pheochromocytoma or paraganglioma. However, nuclear medicine imaging is frequently necessary to determine the nature of the lesions. The purpose of this investigation is to assess which commonly used nuclear medicine modality might have a better diagnostic value in this clinical setting. Eight patients who had been suspected of having either primary pheochromocytoma or primary paraganglioma and 1 patient with known pheochromocytoma were included in the analysis. Among the 8 patients without known diagnosis, 7 had been suggested by anatomical imaging modalities, whereas one of them presented with initial negative anatomical imaging interpretation. All of 9 patients underwent Ga-DOTATATA PET/CT, FDG PET/CT, and MIBG SPECT/CT for further evaluation. The imaging findings were compared with postsurgical pathology and follow-up. Both Ga-DOTATATA PET/CT and MIBG SPECT/CT accurately identified 9 primary tumors, whereas FDG PET/CT showed increased activity in 8 of 9 primary tumors. Both Ga-DOTATATA and FDG PET/CT are able to detect associated extra-adrenal lesions not shown on MIBG study in patients with multiple endocrine neoplasia syndrome. Ga-DOTATATA PET/CT could be the nuclear medicine imaging choice to evaluate suspected primary pheochromocytoma or paraganglioma, especially in the situation of multiple endocrine neoplasia syndrome.

  2. Volumetric Assessment of Swallowing Muscles: A Comparison of CT and MRI Segmentation.

    Science.gov (United States)

    Sporns, Kim Barbara; Hanning, Uta; Schmidt, Rene; Muhle, Paul; Wirth, Rainer; Zimmer, Sebastian; Dziewas, Rainer; Suntrup-Krueger, Sonja; Sporns, Peter Bernhard; Heindel, Walter; Schwindt, Wolfram

    2018-05-01

    MRI-based segmentation of the digastric and geniohyoid muscle are equally feasible. The potential advantage of MRI for prospective studies is the absence of ionizing radiation.   · CT-based segmentation and MRI-based segmentation of the swallowing muscles are equally feasible.. · The advantage of MRI is the absence of ionizing radiation.. · MRI should therefore be deployed for future prospective studies.. · Sporns KB, Hanning U, Schmidt R et al. Volumetric Assessment of Swallowing Muscles: A Comparison of CT and MRI Segmentation. Fortschr Röntgenstr 2018; 190: 441 - 446. © Georg Thieme Verlag KG Stuttgart · New York.

  3. PET/CT comparing 68Ga-DOTATATE and other radiopharmaceuticals and in comparison with CT/MRI for the localization of sporadic metastatic pheochromocytoma and paraganglioma

    International Nuclear Information System (INIS)

    Janssen, Ingo; Chen, Clara C.; Millo, Corina M.; Herscovitch, Peter; Ling, Alexander; Taieb, David; Lin, Frank I.; Adams, Karen T.; Wolf, Katherine I.; Pacak, Karel; Fojo, Antonio T.; Buchmann, Inga; Kebebew, Electron

    2016-01-01

    Pheochromocytomas/paragangliomas (PPGLs) and their metastases are tumors that predominantly express somatostatin receptor 2 (SSR2). 68 Ga-DOTA(0)-Tyr(3)-octreotate ( 68 Ga-DOTATATE) is a PET radiopharmaceutical with both high and selective affinity for SSRs. The purpose of this study was to evaluate the utility of 68 Ga-DOTATATE in comparison with other specific and nonspecific radiopharmaceuticals recommended in the current guidelines for the localization of metastatic sporadic PPGL by PET/CT. This prospective study included 22 patients (15 men, 7 women; aged 50.0 ± 13.9 years) with confirmed metastatic PPGL, a negative family history for PPGL, and negative genetic testing, who underwent 68 Ga-DOTATATE, 18 F-fluoro-2-deoxy-D-glucose ( 18 F-FDG) PET/CT, and CT/MRI. Only 12 patients underwent an additional 18 F-fluorodihydroxyphenylalanine ( 18 F-FDOPA) PET/CT scan and only 11 patients underwent an additional 18 F-fluorodopamine ( 18 F-FDA) PET/CT scan. The rates of detection of metastatic lesions were compared among all the imaging studies. A composite of all functional and anatomical imaging studies served as the imaging comparator. 68 Ga-DOTATATE PET/CT showed a lesion-based detection rate of 97.6 % (95 % confidence interval, CI, 95.8 - 98.7 %). 18 F-FDG PET/CT, 18 F-FDOPA PET/CT, 18 F-FDA PET/CT, and CT/MRI showed detection rates of 49.2 % (CI 44.5 - 53.6 %; p < 0.01), 74.8 % (CI 69.0 - 79.9 %; p < 0.01), 77.7 % (CI 71.5 - 82.8 %; p < 0.01), and 81.6 % (CI 77.8 - 84.8 %; p < 0.01), respectively. The results of this study demonstrate the superiority of 68 Ga-DOTATATE PET/CT in the localization of sporadic metastatic PPGLs compared to all other functional and anatomical imaging modalities, and suggest modification of future guidelines towards this new imaging modality. (orig.)

  4. Comparison of manual and automatic MR-CT registration for radiotherapy of prostate cancer.

    Science.gov (United States)

    Korsager, Anne Sofie; Carl, Jesper; Riis Østergaard, Lasse

    2016-05-08

    In image-guided radiotherapy (IGRT) of prostate cancer, delineation of the clini-cal target volume (CTV) often relies on magnetic resonance (MR) because of its good soft-tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR-CT registration of the prostate has previously been developed using a voxel property-based registration as an alternative to a manual landmark-based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni-Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration.

  5. Comparison of manual and automatic MR‐CT registration for radiotherapy of prostate cancer

    Science.gov (United States)

    Carl, Jesper; Østergaard, Lasse Riis

    2016-01-01

    In image‐guided radiotherapy (IGRT) of prostate cancer, delineation of the clinical target volume (CTV) often relies on magnetic resonance (MR) because of its good soft‐tissue visualization. Registration of MR and computed tomography (CT) is required in order to add this accurate delineation to the dose planning CT. An automatic approach for local MR‐CT registration of the prostate has previously been developed using a voxel property‐based registration as an alternative to a manual landmark‐based registration. The aim of this study is to compare the two registration approaches and to investigate the clinical potential for replacing the manual registration with the automatic registration. Registrations and analysis were performed for 30 prostate cancer patients treated with IGRT using a Ni‐Ti prostate stent as a fiducial marker. The comparison included computing translational and rotational differences between the approaches, visual inspection, and computing the overlap of the CTV. The computed mean translational difference was 1.65, 1.60, and 1.80 mm and the computed mean rotational difference was 1.51°, 3.93°, and 2.09° in the superior/inferior, anterior/posterior, and medial/lateral direction, respectively. The sensitivity of overlap was 87%. The results demonstrate that the automatic registration approach performs registrations comparable to the manual registration. PACS number(s): 87.57.nj, 87.61.‐c, 87.57.Q‐, 87.56.J‐ PMID:27167285

  6. Is CT effective in diagnosing the acute appendicitis?: Focus on comparison of unenhanced CT with barium enema

    International Nuclear Information System (INIS)

    Choi, Seong Hee; Hahm, So Hee; Kang Jin Hwa; Moon, Jeong Hwa

    1994-01-01

    To evaluate the role of unenhanced CT in diagnosing the acute appendicitis. We retrospectively analyzed conventional contrast-enhanced abdominal CT scans of 197 normal patients and barium enemas of 26 out of the 197 patients. Additional unenhanced CT scans of right lower abdomen were performed on 30 patients who were suspected of having acute appendicitis; barium enema was performed in 26 patients. In the analysis of the conventional CT scans, we could detect 132 (67%) normal appendices. On barium enema of 26 out of 197 patients, abruptly narrowed appendix was visualized in 5 cases and luminal irregularity in 4 cases but all 26 cases showed normal appendix on CT. In the 30 cases of unenhanced CT, all appendices were visualized. Among 12 cases which were proved as acute appendicitis, barium enema was done in 10 cases; abruptly narrowed appendix was shown in 3 and luminal irregularity in 1. Among 18 cases which were diagnosed as normal appendix, nonvisualization of appendix was in 1 case, abruptly narrowed lumen in 3, and luminal irregularity in 9. Unenhanced CT in the area of the cecum may be an effective and safe diagnostic tool acute appendicitis

  7. CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction.

    Science.gov (United States)

    Ichikawa, Yasutaka; Kitagawa, Kakuya; Nagasawa, Naoki; Murashima, Shuichi; Sakuma, Hajime

    2013-08-09

    The recently developed model-based iterative reconstruction (MBIR) enables significant reduction of image noise and artifacts, compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP). The purpose of this study was to evaluate lesion detectability of low-dose chest computed tomography (CT) with MBIR in comparison with ASIR and FBP. Chest CT was acquired with 64-slice CT (Discovery CT750HD) with standard-dose (5.7 ± 2.3 mSv) and low-dose (1.6 ± 0.8 mSv) conditions in 55 patients (aged 72 ± 7 years) who were suspected of lung disease on chest radiograms. Low-dose CT images were reconstructed with MBIR, ASIR 50% and FBP, and standard-dose CT images were reconstructed with FBP, using a reconstructed slice thickness of 0.625 mm. Two observers evaluated the image quality of abnormal lung and mediastinal structures on a 5-point scale (Score 5 = excellent and score 1 = non-diagnostic). The objective image noise was also measured as the standard deviation of CT intensity in the descending aorta. The image quality score of enlarged mediastinal lymph nodes on low-dose MBIR CT (4.7 ± 0.5) was significantly improved in comparison with low-dose FBP and ASIR CT (3.0 ± 0.5, p = 0.004; 4.0 ± 0.5, p = 0.02, respectively), and was nearly identical to the score of standard-dose FBP image (4.8 ± 0.4, p = 0.66). Concerning decreased lung attenuation (bulla, emphysema, or cyst), the image quality score on low-dose MBIR CT (4.9 ± 0.2) was slightly better compared to low-dose FBP and ASIR CT (4.5 ± 0.6, p = 0.01; 4.6 ± 0.5, p = 0.01, respectively). There were no significant differences in image quality scores of visualization of consolidation or mass, ground-glass attenuation, or reticular opacity among low- and standard-dose CT series. Image noise with low-dose MBIR CT (11.6 ± 1.0 Hounsfield units (HU)) were significantly lower than with low-dose ASIR (21.1 ± 2.6 HU, p standard-dose FBP CT (16.6 ± 2.3 HU, p 70%, MBIR can provide

  8. Comparison of CT and integrated PET-CT based radiation therapy planning in patients with malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Pehlivan, Berrin; Topkan, Erkan; Onal, Cem; Nursal, Gul Nihal; Yuksel, Oznur; Dolek, Yemliha; Yavuz, Melek Nur; Yavuz, Ali Aydin

    2009-01-01

    When combined with adequate tumoricidal doses, accurate target volume delineation remains to be the one of the most important predictive factors for radiotherapy (RT) success in locally advanced or medically inoperable malignant pleural mesothelioma (MPM) patients. Recently, 18-fluorodeoxyglucose positron emission tomography (PET) has demonstrated significant improvements in diagnosis and accurate staging of MPM. However, role of additional PET data has not been studied in RT planning (RTP) of patients with inoperable MPM or in those who refuse surgery. Therefore, we planned to compare CT with co-registered PET-CT as the basis for delineating target volumes in these patients group. Retrospectively, the CT and co-registered PET-CT data of 13 patients with histologically proven MPM were utilized to delineate target volumes separately. For each patient, target volumes (gross tumor volume [GTV], clinical target volume [CTV], and planning target volume [PTV]) were defined using the CT and PET-CT fusion data sets. The PTV was measured in two ways: PTV1 was CTV plus a 1-cm margin, and PTV2 was GTV plus a 1-cm margin. We analyzed differences in target volumes. In 12 of 13 patients, compared to CT-based delineation, PET-CT-based delineation resulted in a statistically significant decrease in the mean GTV, CTV, PTV1, and PTV2. In these 12 patients, mean GTV decreased by 47.1% ± 28.4%, mean CTV decreased by 38.7% ± 24.7%, mean PTV1 decreased by 31.1% ± 23.1%, and mean PTV2 decreased by 40.0% ± 24.0%. In 4 of 13 patients, hilar lymph nodes were identified by PET-CT that was not identified by CT alone, changing the nodal status of tumor staging in those patients. This study demonstrated the usefulness of PET-CT-based target volume delineation in patients with MPM. Co-registration of PET and CT information reduces the likelihood of geographic misses, and additionally, significant reductions observed in target volumes may potentially allow escalation of RT dose beyond

  9. Comparison of four software packages for CT lung volumetry in healthy individuals

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Stefan F. [Harvard Medical School, Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Molinari, Francesco [Centre Hospitalier Regional Universitaire de Lille, Department of Radiology, Lille (France); Dufresne, Valerie [CHU de Charleroi - Hopital Vesale, Pneumologie, Montigny-le-Tilleul (Belgium); Gosset, Natacha [CHU Tivoli, Service d' Imagerie Medicale, La Louviere (Belgium); Silva, Mario; Bankier, Alexander A. [Harvard Medical School, Department of Radiology, Beth Israel Deaconess Medical Center, Boston, MA (United States)

    2015-06-01

    To compare CT lung volumetry (CTLV) measurements provided by different software packages, and to provide normative data for lung densitometric measurements in healthy individuals. This retrospective study included 51 chest CTs of 17 volunteers (eight men and nine women; mean age, 30 ± 6 years), who underwent spirometrically monitored CT at total lung capacity (TLC), functional residual capacity (FRC), and mean inspiratory capacity (MIC). Volumetric differences assessed by four commercial software packages were compared with analysis of variance (ANOVA) for repeated measurements and benchmarked against the threshold for acceptable variability between spirometric measurements. Mean lung density (MLD) and parenchymal heterogeneity (MLD-SD) were also compared with ANOVA. Volumetric differences ranged from 12 to 213 ml (0.20 % to 6.45 %). Although 16/18 comparisons (among four software packages at TLC, MIC, and FRC) were statistically significant (P < 0.001 to P = 0.004), only 3/18 comparisons, one at MIC and two at FRC, exceeded the spirometry variability threshold. MLD and MLD-SD significantly increased with decreasing volumes, and were significantly larger in lower compared to upper lobes (P < 0.001). Lung volumetric differences provided by different software packages are small. These differences should not be interpreted based on statistical significance alone, but together with absolute volumetric differences. (orig.)

  10. Inter-algorithm lesion volumetry comparison of real and 3D simulated lung lesions in CT

    Science.gov (United States)

    Robins, Marthony; Solomon, Justin; Hoye, Jocelyn; Smith, Taylor; Ebner, Lukas; Samei, Ehsan

    2017-03-01

    The purpose of this study was to establish volumetric exchangeability between real and computational lung lesions in CT. We compared the overall relative volume estimation performance of segmentation tools when used to measure real lesions in actual patient CT images and computational lesions virtually inserted into the same patient images (i.e., hybrid datasets). Pathologically confirmed malignancies from 30 thoracic patient cases from Reference Image Database to Evaluate Therapy Response (RIDER) were modeled and used as the basis for the comparison. Lesions included isolated nodules as well as those attached to the pleura or other lung structures. Patient images were acquired using a 16 detector row or 64 detector row CT scanner (Lightspeed 16 or VCT; GE Healthcare). Scans were acquired using standard chest protocols during a single breath-hold. Virtual 3D lesion models based on real lesions were developed in Duke Lesion Tool (Duke University), and inserted using a validated image-domain insertion program. Nodule volumes were estimated using multiple commercial segmentation tools (iNtuition, TeraRecon, Inc., Syngo.via, Siemens Healthcare, and IntelliSpace, Philips Healthcare). Consensus based volume comparison showed consistent trends in volume measurement between real and virtual lesions across all software. The average percent bias (+/- standard error) shows -9.2+/-3.2% for real lesions versus -6.7+/-1.2% for virtual lesions with tool A, 3.9+/-2.5% and 5.0+/-0.9% for tool B, and 5.3+/-2.3% and 1.8+/-0.8% for tool C, respectively. Virtual lesion volumes were statistically similar to those of real lesions (.05 in most cases. Results suggest that hybrid datasets had similar inter-algorithm variability compared to real datasets.

  11. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  12. Serial automated quantitative CT analysis in idiopathic pulmonary fibrosis. Functional correlations and comparison with changes in visual CT scores

    International Nuclear Information System (INIS)

    Jacob, Joseph; Bartholmai, Brian J.; Rajagopalan, Srinivasan; Kokosi, Maria; Wells, Athol U.; Egashira, Ryoko; Brun, Anne Laure; Nair, Arjun; Walsh, Simon L.F.; Karwoski, Ronald

    2018-01-01

    To determine whether computer-based CT quantitation of change can improve on visual change quantification of parenchymal features in IPF. Sixty-six IPF patients with serial CT imaging (6-24 months apart) had CT features scored visually and with a computer software tool: ground glass opacity, reticulation and honeycombing (all three variables summed as interstitial lung disease extent [ILD]) and emphysema. Pulmonary vessel volume (PVV) was estimated by computer only. Relationships between changes in CT features and forced vital capacity (FVC) were examined using univariate and multivariate linear regression analyses. On univariate analysis, changes in computer variables demonstrated stronger linkages to FVC change than changes in visual scores (CALIPER ILD:R 2 =0.53, p<0.0001; Visual ILD:R 2 =0.16, p=0.001). PVV increase correlated most strongly with relative FVC change (R 2 =0.57). When PVV constituents (vessel size and location) were examined, an increase in middle zone vessels linked most strongly to FVC decline (R 2 =0.57) and was independent of baseline disease severity (characterised by CT fibrosis extent, FVC, or DLco). An increase in PVV, specifically an increase in middle zone lung vessels, was the strongest CT determinant of FVC decline in IPF and was independent of baseline disease severity. (orig.)

  13. Comparison of CT and MRI in patients with tibial plateau fracture: can CT findings predict ligament tear or meniscal injury?

    International Nuclear Information System (INIS)

    Mui, Leonora W.; Engelsohn, Eliyahu; Umans, Hilary

    2007-01-01

    (1) To determine the accuracy of computed tomography (CT) in the evaluation of ligament tear and avulsion in patients with tibial plateau fracture. (2) To evaluate whether the presence or severity of fracture gap and articular depression can predict meniscal injury. A fellowship-trained musculoskeletal radiologist retrospectively reviewed knee CT and MRI examinations of 41 consecutive patients presenting to a level 1 trauma center with tibial plateau fractures. Fracture gap, articular depression, ligament tear and footprint avulsions were assessed on CT examinations. The MRI studies were examined for osseous and soft tissue injuries, including meniscal tear, meniscal displacement, ligament tear, and ligament avulsion. CT demonstrated torn ligaments with 80% sensitivity and 98% specificity. Only 2% of ligaments deemed intact on careful CT evaluation had partial or complete tears on MRI. Although the degree of fracture gap and articular depression was significantly greater in patients with meniscal injury compared with those without meniscal injury, ROC analysis demonstrated no clear threshold for gap or depression that yielded a combination of high sensitivity and specificity. In the acute setting, CT offers high sensitivity and specificity for depicting osseous avulsions, as well as high negative predictive value for excluding ligament injury. However, MRI remains necessary for the preoperative detection of meniscal injury. (orig.)

  14. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  15. Serial automated quantitative CT analysis in idiopathic pulmonary fibrosis. Functional correlations and comparison with changes in visual CT scores

    Energy Technology Data Exchange (ETDEWEB)

    Jacob, Joseph; Bartholmai, Brian J.; Rajagopalan, Srinivasan [Mayo Clinic Rochester, Division of Radiology, Rochester, MN (United States); Kokosi, Maria; Wells, Athol U. [Royal Brompton and Harefield NHS Foundation Trust, Interstitial Lung Disease Unit, Royal Brompton Hospital, London (United Kingdom); Egashira, Ryoko [Saga Daigaku, Department of Radiology, Saga (Japan); Brun, Anne Laure [Whittington Hospital, Department of Radiology, London (United Kingdom); Nair, Arjun [Guys and St Thomas' NHS Foundation Trust, Department of Radiology, London (United Kingdom); Walsh, Simon L.F. [Kings College Hospital NHS Foundation Trust, Department of Radiology, London (United Kingdom); Karwoski, Ronald [Mayo Clinic Rochester, Department of Physiology and Biomedical Engineering, Rochester, MN (United States)

    2018-03-15

    To determine whether computer-based CT quantitation of change can improve on visual change quantification of parenchymal features in IPF. Sixty-six IPF patients with serial CT imaging (6-24 months apart) had CT features scored visually and with a computer software tool: ground glass opacity, reticulation and honeycombing (all three variables summed as interstitial lung disease extent [ILD]) and emphysema. Pulmonary vessel volume (PVV) was estimated by computer only. Relationships between changes in CT features and forced vital capacity (FVC) were examined using univariate and multivariate linear regression analyses. On univariate analysis, changes in computer variables demonstrated stronger linkages to FVC change than changes in visual scores (CALIPER ILD:R{sup 2}=0.53, p<0.0001; Visual ILD:R{sup 2}=0.16, p=0.001). PVV increase correlated most strongly with relative FVC change (R{sup 2}=0.57). When PVV constituents (vessel size and location) were examined, an increase in middle zone vessels linked most strongly to FVC decline (R{sup 2}=0.57) and was independent of baseline disease severity (characterised by CT fibrosis extent, FVC, or DLco). An increase in PVV, specifically an increase in middle zone lung vessels, was the strongest CT determinant of FVC decline in IPF and was independent of baseline disease severity. (orig.)

  16. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT

    Energy Technology Data Exchange (ETDEWEB)

    Hutt, Antoine; Faivre, Jean-Baptiste; Remy, Jacques; Remy-Jardin, Martine [CHRU et Universite de Lille, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain; Deken, Valerie [CHRU et Universite de Lille, Department of Biostatistics (EA 2694), Lille (France); Molinari, Francesco [Centre Hospitalier General de Tourcoing, Department of Radiology, Tourcoing (France)

    2016-06-15

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. (orig.)

  17. Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.

    Science.gov (United States)

    Li, Yongrui; Li, Ye; Jackson, Alan; Li, Xiaodong; Huang, Ning; Guo, Chunjie; Zhang, Huimao

    2017-01-01

    To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT. 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing. The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%. VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine

  18. WE-AB-202-07: Ventilation CT: Voxel-Level Comparison with Hyperpolarized Helium-3 & Xenon-129 MRI

    Energy Technology Data Exchange (ETDEWEB)

    Tahir, B; Marshall, H; Hughes, P; Stewart, N; Horn, F; Collier, G; Norquay, G; Hart, K; Swinscoe, J; Hatton, M; Wild, J; Ireland, R [University of Sheffield, Sheffield (United Kingdom)

    2016-06-15

    Purpose: To compare the spatial correlation of ventilation surrogates computed from inspiratory and expiratory breath-hold CT with hyperpolarized Helium-3 & Xenon-129 MRI in a cohort of lung cancer patients. Methods: 5 patients underwent expiration & inspiration breath-hold CT. Xenon-129 & {sup 1}H MRI were also acquired at the same inflation state as inspiratory CT. This was followed immediately by acquisition of Helium-3 & {sup 1}H MRI in the same breath and at the same inflation state as inspiratory CT. Expiration CT was deformably registered to inspiration CT for calculation of ventilation CT from voxel-wise differences in Hounsfield units. Inspiration CT and the Xenon-129’s corresponding anatomical {sup 1}H MRI were registered to Helium-3 MRI via the same-breath anatomical {sup 1}H MRI. This enabled direct comparison of CT ventilation with Helium-3 MRI & Xenon-129 MRI for the median values in corresponding regions of interest, ranging from finer to coarser in-plane dimensions of 10 by 10, 20 by 20, 30 by 30 and 40 by 40, located within the lungs as defined by the same-breath {sup 1}H MRI lung mask. Spearman coefficients were used to assess voxel-level correlation. Results: The median Spearman’s coefficients of ventilation CT with Helium-3 & Xenon-129 MRI for ROIs of 10 by 10, 20 by 20, 30 by 30 and 40 by 40 were 0.52, 0.56, 0.60 and 0.68 and 0.40, 0.42, 0.52 and 0.70, respectively. Conclusion: This work demonstrates a method of acquiring CT & hyperpolarized gas MRI (Helium-3 & Xenon-129 MRI) in similar breath-holds to enable direct spatial comparison of ventilation maps. Initial results show moderate correlation between ventilation CT & hyperpolarized gas MRI, improving for coarser regions which could be attributable to the inherent noise in CT intensity, non-ventilatory effects and registration errors at the voxel-level. Thus, it may be more beneficial to quantify ventilation at a more regional level.

  19. Comparison of CT during arterial portography, delayed iodine CT, and MR imaging for the preoperative evaluation of hepatic tumors

    International Nuclear Information System (INIS)

    Nelson, R.C.; Chezmar, J.L.; Sugarbaker, P.H.; Bernardino, M.E.

    1988-01-01

    Twenty-eight patients with neoplastic involvement of the liver were studied with CT during arterial portography, delayed iodine CT, and MR imaging, to determine the number, size, and location of focal hepatic lesions prior to hepatic tumor surgery. The MR pulse-sequences used included T1- and T2-weighted spin-echo (SE) sequences and inversion-recovery (IR) sequences at 0.5 T, 1.5 T, or both. Results were compared with operative and pathologic findings. The sensitivities for the detection of individual focal lesions are as follows: CT during arterial portography, delayed iodine CT, 77%, IR at 0.5 T, 74%; T1-weighted SE at 0.5 T, 69%; T2-weighted SE at 1.5 T, 55%, IR at 1.5 T, 50%; T2-weighted SE at 0.5 T, 48%, and T1-weighted SE at 1.5 T, 31%. The positive predictive values ranged from 88% to 100% for all techniques. The authors' data suggest that CT during arterial portography is a superior technique for evaluating patients prior to hepatic tumor surgery

  20. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Yoshikawa, Takeshi; Takenaka, Daisuke; Fujisawa, Yasuko; Sugihara, Naoki; Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro

    2017-01-01

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV 1 . Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV 1 (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  1. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  2. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  3. CT patterns of fungal pulmonary infections of the lung: Comparison of standard-dose and simulated low-dose CT

    International Nuclear Information System (INIS)

    Christe, Andreas; Lin, Margaret C.; Yen, Andrew C.; Hallett, Rich L.; Roychoudhury, Kingshuk; Schmitzberger, Florian; Fleischmann, Dominik; Leung, Ann N.; Rubin, Geoffry D.; Vock, Peter; Roos, Justus E.

    2012-01-01

    Purpose: To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients. Materials and methods: Raw data of thoracic CT scans (64 × 0.75 mm, 120 kVp, 300 reference mAs) from 41 consecutive patients with clinical suspicion of pulmonary fungal infection were collected. In 32 patients fungal infection could be proven (median age of 55.5 years, range 35–83). A total of 267 cuboids showing CT patterns of fungal infection and 27 cubes having no disease were reconstructed at the original and 6 simulated tube currents of 100, 40, 30, 20, 10, and 5 reference mAs. Eight specific fungal CT patterns were analyzed by three radiologists: 76 ground glass opacities, 42 ground glass nodules, 51 mixed, part solid, part ground glass nodules, 36 solid nodules, 5 lobulated nodules, 6 spiculated nodules, 14 cavitary nodules, and 37 foci of air-space disease. The standard of reference was a consensus subjective interpretation by experts whom were not readers in the study. Results: The mean sensitivity and standard deviation for detecting pathological cuboids/disease using standard dose CT was 0.91 ± 0.07. Decreasing dose did not affect sensitivity significantly until the lowest dose level of 5 mAs (0.87 ± 0.10, p = 0.012). Nodular pattern discrimination was impaired below the dose level of 30 reference mAs: specificity for fungal ‘mixed nodules’ decreased significantly at 20, 10 and 5 reference mAs (p < 0.05). At lower dose levels, classification drifted from ‘solid’ to ‘mixed nodule’, although no lesion was missed. Conclusion: Our simulation data suggest that tube current levels can be reduced from 300 to 30 reference mAs without impairing the diagnostic information of specific CT patterns of pulmonary fungal infections

  4. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    International Nuclear Information System (INIS)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M.; Welte, T.; Kropf, S.

    2000-01-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  5. Diagnostic potential of virtual bronchoscopy: advantages in comparison with axial CT slices, MPR and mIP?

    Energy Technology Data Exchange (ETDEWEB)

    Rapp-Bernhardt, U.; Doehring, W.; Bernhardt, T.M. [Department of Diagnostic Radiology, Otto-von-Guericke University, Magdeburg (Germany); Welte, T. [Department of Cardiology, Angiology, and Pneumology, Otto-von-Guericke University, Magdeburg (Germany); Kropf, S. [Department of Biometrics and Medical Informatics, Otto-von-Guericke University, Magdeburg (Germany)

    2000-06-01

    The aim of this study was to evaluate the diagnostic potential of virtual endoscopy (VE) and to compare it with axial CT slices, multiplanar reconstructions (MPR), minimal intensity projections (mIP), and bronchoscopy in patients diagnosed with bronchogenic carcinoma. Thirty patients underwent a spiral CT. Axial CT images were transferred to an Onyx workstation (Silicon Graphics, Sun Microsystems, Mountain View, Calif.) for performing virtual endoscopy. Accuracy for this procedure was tested by three radiologists on a monitor in comparison with axial CT slices, MPR, mIP, and bronchoscopy concerning the localization and degree of stenoses. Endoluminal tumors were identified by virtual bronchoscopy with no statistically significant difference of localization or grading of stenosis in comparison with bronchoscopy, axial CT slices, MPR and mIP. Axial CT slices, MPR, and mIP showed poorer results with over- or underestimation of stenoses compared with VE and bronchoscopy. Passing of stenoses was only possible with VE in 5 patients. Virtual endoscopy is a non-invasive method for identification of endoluminal tumors and is comparable to real bronchoscopy. (orig.)

  6. Comparison between plain chest film and CT in estimating the size of pneumothorax

    International Nuclear Information System (INIS)

    Seto, Yuichi

    1995-01-01

    Regarding the patients diagnosed as having traumatic and spontaneous pneumothorax at our emergency center within the past 6 years we examined the distribution of pneumothorax shown by plain chest film and CT, and compared the pneumothorax rate evaluated by Kircher's method with plain chest film and that by one slice method with CT, which was based on full slice integration method with CT. Occult pneumothorax was found in 47.6% of traumatic cases and 11.1% of spontaneous cases. The distribution of pneumothoraces showed no significant differences. However, as compared with classical pneumothorax, the ratio of pneumothoraces in the apicolateral recess in the occult pneumothoraces tended to be lower, whereas the ratio of the ones in the anteromedial recess and in the subpulmonic recess tended to be comparatively high. The plain chest film of occult pneumothorax had been taken on supine position in most cases of traumatic pneumothorax and in more than half the cases of spontaneous pneumothorax. This was considered to be the cause of the unique distribution of pneumothorax. The pneumothorax rate evaluated by Kircher's method tended to be underestimated in comparison with the basic rate, where the correlation coefficient was R=0.84 for traumatic pneumothorax and R=0.14 for spontaneous pneumothorax. Especially in the cases of low pneumothorax rate the correlation was poor. The pneumothorax rate calculated by one slice method produced better figures with the correlation coefficient of R=0.92 for traumatic pneumothorax and R=0.85 for spontaneous pneumothorax. The one slice method was considered to be effective in evaluation of the degree of serious cases, and also for the choice of treatment modality for pneumothorax. (author)

  7. Comparison of an adaptive local thresholding method on CBCT and µCT endodontic images

    Science.gov (United States)

    Michetti, Jérôme; Basarab, Adrian; Diemer, Franck; Kouame, Denis

    2018-01-01

    Root canal segmentation on cone beam computed tomography (CBCT) images is difficult because of the noise level, resolution limitations, beam hardening and dental morphological variations. An image processing framework, based on an adaptive local threshold method, was evaluated on CBCT images acquired on extracted teeth. A comparison with high quality segmented endodontic images on micro computed tomography (µCT) images acquired from the same teeth was carried out using a dedicated registration process. Each segmented tooth was evaluated according to volume and root canal sections through the area and the Feret’s diameter. The proposed method is shown to overcome the limitations of CBCT and to provide an automated and adaptive complete endodontic segmentation. Despite a slight underestimation (-4, 08%), the local threshold segmentation method based on edge-detection was shown to be fast and accurate. Strong correlations between CBCT and µCT segmentations were found both for the root canal area and diameter (respectively 0.98 and 0.88). Our findings suggest that combining CBCT imaging with this image processing framework may benefit experimental endodontology, teaching and could represent a first development step towards the clinical use of endodontic CBCT segmentation during pulp cavity treatment.

  8. A comparison between intrastomal 3D ultrasonography, CT scanning and findings at surgery in patients with stomal complaints.

    Science.gov (United States)

    Näsvall, P; Wikner, F; Gunnarsson, U; Rutegård, J; Strigård, K

    2014-10-01

    Since there are no reliable investigative tools for imaging parastomal hernia, new techniques are needed. The aim of this study was to assess the validity of intrastomal three-dimensional ultrasonography (3D) as an alternative to CT scanning for the assessment of stomal complaints. Twenty patients with stomal complaints, indicating surgery, were examined preoperatively with a CT scan in the supine position and 3D intrastomal ultrasonography in the supine and erect positions. Comparison with findings at surgery, considered to be the true state, was made. Both imaging methods, 3D ultrasonography and CT scanning, showed high sensitivity (ultrasound 15/18, CT scan 15/18) and specificity (ultrasound 2/2, CT scan 1/2) when judged by a dedicated radiologist. Corresponding values for interpretation of CT scans in routine clinical practice was for sensitivity 17/18 and for specificity 1/2. 3D ultrasonography has a high validity and is a promising alternative to CT scanning in the supine position to distinguish a bulge from a parastomal hernia.

  9. Preoperative evaluation of synchronous colorectal cancer using MR colonography

    DEFF Research Database (Denmark)

    Achiam, Michael P; Holst Andersen, Lars P; Klein, Mads

    2009-01-01

    RATIONALE AND OBJECTIVES: It is well known that synchronous cancers (incidence, 2%-11%) and polyps (incidence, 12%-58%) occur in patients with colorectal cancer. Magnetic resonance colonography (MRC) seems like the obvious choice as a diagnostic tool in preoperative evaluation, because...... a full conventional colonoscopy or in whom full conventional colonoscopy was not possible. MATERIALS AND METHODS: In a 13-month period, 47 patients diagnosed with rectal or sigmoid colon cancer scheduled for operation were included in the study. MRC was performed with bowel purgation either the night...... before surgery or as ambulatory MRC the week before surgery. RESULTS: Full MRC was performed in 98% of the patients. In four patients, 12 synchronous lesions (one cancer, two plaques of carcinosis, and nine adenomas) were found. One flat adenoma and five small polyps were missed by MRC and perioperative...

  10. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    International Nuclear Information System (INIS)

    Atzingen, Augusto Castelli von; Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares; D'Ippolito, Giuseppe

    2012-01-01

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  11. Parallel imaging enhanced MR colonography using a phantom model.

    LENUS (Irish Health Repository)

    Morrin, Martina M

    2008-09-01

    To compare various Array Spatial and Sensitivity Encoding Technique (ASSET)-enhanced T2W SSFSE (single shot fast spin echo) and T1-weighted (T1W) 3D SPGR (spoiled gradient recalled echo) sequences for polyp detection and image quality at MR colonography (MRC) in a phantom model. Limitations of MRC using standard 3D SPGR T1W imaging include the long breath-hold required to cover the entire colon within one acquisition and the relatively low spatial resolution due to the long acquisition time. Parallel imaging using ASSET-enhanced T2W SSFSE and 3D T1W SPGR imaging results in much shorter imaging times, which allows for increased spatial resolution.

  12. Common findings and pseudolesions at computed tomography colonography: pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Atzingen, Augusto Castelli von [Clinical Radiology, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); Tiferes, Dario Ariel; Matsumoto, Carlos Alberto; Nunes, Thiago Franchi; Maia, Marcos Vinicius Alvim Soares [Abdominal Imaging Section, Department of Imaging Diagnosis - Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil); D' Ippolito, Giuseppe, E-mail: giuseppe_dr@uol.com.br [Department of Imaging Diagnosis, Universidade Federal de Sao Paulo (UNIFESP), Sao Paulo, SP (Brazil)

    2012-05-15

    Computed tomography colonography is a minimally invasive method for screening for polyps and colorectal cancer, with extremely unusual complications, increasingly used in the clinical practice. In the last decade, developments in bowel preparation, imaging, and in the training of investigators have determined a significant increase in the method sensitivity. Images interpretation is accomplished through a combined analysis of two-dimensional source images and several types of three-dimensional renderings, with sensitivity around 96% in the detection of lesions with dimensions equal or greater than 10 mm in size, when analyzed by experienced radiologists. The present pictorial essay includes examples of diseases and pseudolesions most frequently observed in this type of imaging study. The authors present examples of flat and polypoid lesions, benign and malignant lesions, diverticular disease of the colon, among other conditions, as well as pseudolesions, including those related to inappropriate bowel preparation and misinterpretation. (author)

  13. Intra-individual diagnostic image quality and organ-specific-radiation dose comparison between spiral cCT with iterative image reconstruction and z-axis automated tube current modulation and sequential cCT

    International Nuclear Information System (INIS)

    Wenz, Holger; Maros, Máté E.; Meyer, Mathias; Gawlitza, Joshua; Förster, Alex; Haubenreisser, Holger; Kurth, Stefan; Schoenberg, Stefan O.; Groden, Christoph; Henzler, Thomas

    2016-01-01

    •Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose.•Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT.•State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. Superiority of spiral versus sequential cCT in image quality and organ-specific-radiation dose. Spiral cCT: lower organ-specific-radiation-dose in eye lense compared to tilted sequential cCT. State-of-the-art IR spiral cCT techniques has significant advantages over sequential cCT techniques. To prospectively evaluate image quality and organ-specific-radiation dose of spiral cranial CT (cCT) combined with automated tube current modulation (ATCM) and iterative image reconstruction (IR) in comparison to sequential tilted cCT reconstructed with filtered back projection (FBP) without ATCM. 31 patients with a previous performed tilted non-contrast enhanced sequential cCT aquisition on a 4-slice CT system with only FBP reconstruction and no ATCM were prospectively enrolled in this study for a clinical indicated cCT scan. All spiral cCT examinations were performed on a 3rd generation dual-source CT system using ATCM in z-axis direction. Images were reconstructed using both, FBP and IR (level 1–5). A Monte-Carlo-simulation-based analysis was used to compare organ-specific-radiation dose. Subjective image quality for various anatomic structures was evaluated using a 4-point Likert-scale and objective image quality was evaluated by comparing signal-to-noise ratios (SNR). Spiral cCT led to a significantly lower (p < 0.05) organ-specific-radiation dose in all targets including eye lense. Subjective image quality of spiral cCT datasets with an IR reconstruction level 5 was rated significantly higher compared to the sequential cCT acquisitions (p < 0.0001). Consecutive mean SNR was significantly higher in all spiral datasets (FBP, IR 1–5) when compared to sequential cCT with a mean

  14. Spectral detector CT-derived virtual non-contrast images: comparison of attenuation values with unenhanced CT.

    Science.gov (United States)

    Ananthakrishnan, Lakshmi; Rajiah, Prabhakar; Ahn, Richard; Rassouli, Negin; Xi, Yin; Soesbe, Todd C; Lewis, Matthew A; Lenkinski, Robert E; Leyendecker, John R; Abbara, Suhny

    2017-03-01

    To assess virtual non-contrast (VNC) images obtained on a detection-based spectral detector CT scanner and determine how attenuation on VNC images derived from various phases of enhanced CT compare to those obtained from true unenhanced images. In this HIPAA compliant, IRB approved prospective multi-institutional study, 46 patients underwent pre- and post-contrast imaging on a prototype dual-layer spectral detector CT between October 2013 and November 2015, yielding 84 unenhanced and VNC pairs (25 arterial, 39 portal venous/nephrographic, 20 urographic). Mean attenuation was measured by one of three readers in the liver, spleen, kidneys, psoas muscle, abdominal aorta, and subcutaneous fat. Equivalence testing was used to determine if the mean difference between unenhanced and VNC attenuation was less than 5, 10, or 15 HU. VNC image quality was assessed on a 5 point scale. Mean difference between unenhanced and VNC attenuation was VNC attenuation were equivalent in all tissues except fat using a threshold of VNC overestimated the HU relative to unenhanced images. VNC image quality was rated as excellent or good in 84% of arterial phase and 85% of nephrographic phase cases, but only 40% of urographic phase. VNC images derived from novel dual layer spectral detector CT demonstrate attenuation values similar to unenhanced images in all tissues evaluated except for subcutaneous fat. Further study is needed to determine if attenuation thresholds currently used clinically for common pathology should be adjusted, particularly for lesions containing fat.

  15. Quantitative comparison of noise texture across CT scanners from different manufacturers

    International Nuclear Information System (INIS)

    Solomon, Justin B.; Christianson, Olav; Samei, Ehsan

    2012-01-01

    Purpose: To quantitatively compare noise texture across computed tomography (CT) scanners from different manufacturers using the noise power spectrum (NPS). Methods: The American College of Radiology CT accreditation phantom (Gammex 464, Gammex, Inc., Middleton, WI) was imaged on two scanners: Discovery CT 750HD (GE Healthcare, Waukesha, WI), and SOMATOM Definition Flash (Siemens Healthcare, Germany), using a consistent acquisition protocol (120 kVp, 0.625/0.6 mm slice thickness, 250 mAs, and 22 cm field of view). Images were reconstructed using filtered backprojection and a wide selection of reconstruction kernels. For each image set, the 2D NPS were estimated from the uniform section of the phantom. The 2D spectra were normalized by their integral value, radially averaged, and filtered by the human visual response function. A systematic kernel-by-kernel comparison across manufacturers was performed by computing the root mean square difference (RMSD) and the peak frequency difference (PFD) between the NPS from different kernels. GE and Siemens kernels were compared and kernel pairs that minimized the RMSD and |PFD| were identified. Results: The RMSD (|PFD|) values between the NPS of GE and Siemens kernels varied from 0.01 mm 2 (0.002 mm −1 ) to 0.29 mm 2 (0.74 mm −1 ). The GE kernels “Soft,”“Standard,”“Chest,” and “Lung” closely matched the Siemens kernels “B35f,”“B43f,”“B41f,” and “B80f” (RMSD 2 , |PFD| −1 , respectively). The GE “Bone,”“Bone+,” and “Edge” kernels all matched most closely with Siemens “B75f” kernel but with sizeable RMSD and |PFD| values up to 0.18 mm 2 and 0.41 mm −1 , respectively. These sizeable RMSD and |PFD| values corresponded to visually perceivable differences in the noise texture of the images. Conclusions: It is possible to use the NPS to quantitatively compare noise texture across CT systems. The degree to which similar texture across scanners could be achieved varies and is

  16. Comparison of two different segmentation methods on planar lung perfusion scan with reference to quantitative value on SPECT/CT

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Min Seok; Kang, Yeon Koo; Ha, Seung Gyun [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); and others

    2017-06-15

    Until now, there was no single standardized regional segmentation method of planar lung perfusion scan. We compared planar scan based two segmentation methods, which are frequently used in the Society of Nuclear Medicine, with reference to the lung perfusion single photon emission computed tomography (SPECT)/computed tomography (CT) derived values in lung cancer patients. Fifty-five lung cancer patients (male:female, 37:18; age, 67.8 ± 10.7 years) were evaluated. The patients underwent planar scan and SPECT/CT after injection of technetium-99 m macroaggregated albumin (Tc-99 m-MAA). The % uptake and predicted postoperative percentage forced expiratory volume in 1 s (ppoFEV1%) derived from both posterior oblique (PO) and anterior posterior (AP) methods were compared with SPECT/CT derived parameters. Concordance analysis, paired comparison, reproducibility analysis and spearman correlation analysis were conducted. The % uptake derived from PO method showed higher concordance with SPECT/CT derived % uptake in every lobe compared to AP method. Both methods showed significantly different lobar distribution of % uptake compared to SPECT/CT. For the target region, ppoFEV1% measured from PO method showed higher concordance with SPECT/CT, but lower reproducibility compared to AP method. Preliminary data revealed that every method significantly correlated with actual postoperative FEV1%, with SPECT/CT showing the best correlation. The PO method derived values showed better concordance with SPECT/CT compared to the AP method. Both PO and AP methods showed significantly different lobar distribution compared to SPECT/CT. In clinical practice such difference according to different methods and lobes should be considered for more accurate postoperative lung function prediction.

  17. A comparison of the value of MRI and CT in patients with Nelson syndrome

    International Nuclear Information System (INIS)

    Kersjes, W.; Allmendinger, S.; Christ, F.; Stiebler, H.; Bockisch, A.; Klingmueller, D.

    1992-01-01

    The hypophyses of 13 patients with Nelson syndrome following bilateral adrenalectomy were examined by MRI and CT. Diffuse enlargement of the hypophysis was demonstrated in 8 patients by CT and in 9 by MRI. Compared with CT, MRI provides better demonstration of tumour development, such as abnormal convexity of the cranial margin of the hypophysis (MRI 4/13, CT 1/13), displacement of the infundibulum (MRI 4/13, CT 0/13) or optic chiasm (MRI 2/13, CT 0/13). MRI also provides diagnostically important differentiation between scar tissue and recurrence of tumour following hypophysectomy (MRI 1/3, CT 0/3) and more accurate demonstration of infiltration of the cavernous sinus (MRI 4/13, CT 2/13). CT is superior only in showing the floor of the sella. MRI is the method of choice for imaging in cases of Nelson syndrome. (orig.) [de

  18. Patient acceptance of MR colonography with improved fecal tagging versus conventional colonoscopy

    International Nuclear Information System (INIS)

    Achiam, M.P.; Logager, V.; Chabanova, E.; Thomsen, H.S.; Rosenberg, J.

    2010-01-01

    Objective: Conventional colonoscopy (CC) is the gold standard for colonic examinations. However, patient acceptance is not high. Patient acceptance is influenced by several factors, notably anticipation and experience. This has led to the assumption that patient acceptance would be higher in non-invasive examinations such as MR/CT colonography (MRC/CTC) and perhaps even higher without bowel preparation. The purpose of this study was to evaluate patient acceptance of MRC with fecal tagging versus CC. Materials and methods: In a 14-month period, all patients first-time referred to our department for CC were asked to participate in the study. Two days prior to MRC, patients ingested an oral contrast mixture (barium/ferumoxsil) together with four meals each day. Standard bowel purgation was performed before CC. Before and after MRC and CC a number of questions were addressed. Results: Sixty-four (34 men, 30 women) patients referred for CC participated in the study. 27% had some discomfort ingesting the contrast mixture, and 49% had some discomfort with the bowel purgation. As a future colonic examination preference, 71% preferred MRC, 13% preferred CC and 15% had no preference. If MRC was to be performed with bowel purgation, 75% would prefer MRC, 12% would prefer CC and 12% had no preference. Conclusion: This study shows that there is a potential gain in patient acceptance by using MRC for colonic examination, since MRC is considered less painful and less unpleasant than CC. In addition, the results indicate that patients in this study prefer fecal tagging instead of bowel purgation.

  19. Computed tomographic colonography (CTC) performance: one-year clinical follow-up

    International Nuclear Information System (INIS)

    Duff, S.E.; Murray, D.; Rate, A.J.; Richards, D.M.; Kumar, N.A. Mahesh

    2006-01-01

    Aim: Computed tomographic colonography (CTC) represents a valuable advance in imaging technology for patients with colonic symptoms who are unfit for or fail to complete investigation with conventional techniques of colonoscopy or barium enema. The aim of this study was to examine whether CTC was sufficient to exclude colorectal cancer in such a population. As our patients were unfit for or unable to complete conventional investigations, we used 1 year clinical follow-up to exclude colonic malignancy. Materials and Methods: CTC examination was performed using multi-slice CT in patients fitting pre-determined criteria. All patients who had completed 12 months of follow-up after CTC were included. Data were extracted from patient records and lack of presentation within the 12 months following a negative CTC was assumed to equate to lack of colorectal cancer at initial investigation. Results: One hundred and twelve patients underwent CTC with a median age of 78 years (range 39-95) and median follow-up of 18 months (range 12-26). CTC detected 7 colorectal cancers, with 3 false positives and 1 false negative, giving a sensitivity of 87.5% and specificity of 97.1% for the detection of colorectal cancer. Conclusions: CTC is a good imaging tool for the exclusion of colorectal cancer in a population unfit for or unable to complete colonoscopy or barium enema, with reasonable sensitivity and specificity for detection of colorectal cancer. However, the optimum investigative strategy for fitter symptomatic individuals is still debated and should be clarified by the results of ongoing randomised controlled trials

  20. Availability, Indications, and Technical Performance of Computed Tomographic Colonography: A National Survey

    International Nuclear Information System (INIS)

    Fisichella, V.; Hellstroem, M.

    2006-01-01

    Purpose: To determine the availability, indications, and technique of computed tomographic colonography (CTC) in Sweden and to investigate opinions on its future role in colon imaging. Material and Methods: In May 2004, a questionnaire on CTC was mailed to all Departments of Radiology in Sweden, and one year later a telephone interview was conducted with the departments that intended to start a CTC service. Results: Ninety-nine departments (83%) answered the questionnaire, indicating that 23/99 (23.2%) offered a CTC service. Reasons for non-implementation of CTC were lack of CTC training in 34/73 (46.6%) and non-availability of multi-detector row CT scanners in 33/73 (45.2%), while 26% were awaiting further scientific documentation on CTC. Incomplete colonoscopy was the main indication for CTC in 21/23 (91.3%) departments performing CTC. Dual positioning, room air insufflation, and thin-slice collimation were used in all the responding departments. The number of CTC studies performed varied from 1-5 (26.1%) to more than 200 (17.4%). Intravenous contrast material was routinely administered by 9/23 (39.1%) departments. Out of 30 (39.5%) departments that in 2004 intended to start CTC, 9 (30%) had done so by June 2005. A total of 32/99 (32.3%) departments had therefore started CTC by June 2005. Half of the departments that replied believed that CTC would absolutely or probably replace barium enema in the future. Conclusion: The survey shows relatively limited diffusion of CTC practice in Sweden, with approximately one-third of radiology departments offering a CTC service, mostly on a small scale. A wider dissemination of CTC requires further scientific documentation of its capability, intensified educational efforts, and additional funding

  1. Cost-effectiveness of computed tomography colonography in colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Hanly, Paul; Skally, Mairead; Fenlon, Helen; Sharp, Linda

    2012-10-01

    The European Code Against Cancer recommends individuals aged ≥ 50 should participate in colorectal cancer screening. CT-colonography (CTC) is one of several screening tests available. We systematically reviewed evidence on, and identified key factors influencing, cost-effectiveness of CTC screening. PubMed, Medline, and the Cochrane library were searched for cost-effectiveness or cost-utility analyses of CTC-based screening, published in English, January 1999 to July 2010. Data was abstracted on setting, model type and horizon, screening scenario(s), comparator(s), participants, uptake, CTC performance and cost, effectiveness, ICERs, and whether extra-colonic findings and medical complications were considered. Sixteen studies were identified from the United States (n = 11), Canada (n = 2), and France, Italy, and the United Kingdom (1 each). Markov state-transition (n = 14) or microsimulation (n = 2) models were used. Eleven considered direct medical costs only; five included indirect costs. Fourteen compared CTC with no screening; fourteen compared CTC with colonoscopy-based screening; fewer compared CTC with sigmoidoscopy (8) or fecal tests (4). Outcomes assessed were life-years gained/saved (13), QALYs (2), or both (1). Three considered extra-colonic findings; seven considered complications. CTC appeared cost-effective versus no screening and, in general, flexible sigmoidoscopy and fecal occult blood testing. Results were mixed comparing CTC to colonoscopy. Parameters most influencing cost-effectiveness included: CTC costs, screening uptake, threshold for polyp referral, and extra-colonic findings. Evidence on cost-effectiveness of CTC screening is heterogeneous, due largely to between-study differences in comparators and parameter values. Future studies should: compare CTC with currently favored tests, especially fecal immunochemical tests; consider extra-colonic findings; and conduct comprehensive sensitivity analyses.

  2. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography.

    Science.gov (United States)

    Tao, Shu Min; Li, Xie; Schoepf, U Joseph; Nance, John W; Jacobs, Brian E; Zhou, Chang Sheng; Gu, Hai Feng; Lu, Meng Jie; Lu, Guang Ming; Zhang, Long Jiang

    2018-04-01

    To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Diagnosis of Meningeoma: A comparison of costs before CT, during CT and after introduction of MR imaging

    International Nuclear Information System (INIS)

    Laurila, J.; Suramo, I.; Brommels, M.; Servo, A.; Kotikangas, J.; Standertskjoeld-Nordenstam, C.G.

    2000-01-01

    To assess whether the capital investment required by advances in radiological technology is offset by savings in the direct costs of diagnostic services. Material and Methods: Meningeoma was used as an indicator case. All meningeoma patients from three study periods were included: Twenty patients in 1976-77 before the introduction of CT, 22 patients in 1984-85 when CT was used and 16 patients in 1992 when MR imaging had replaced CT as the most informative imaging modality. Radiological and other diagnostic investigations, and the hospital stay were identified and cost analyzed. Results: The costs of radiological examinations increased from 293 Euros in 1976/77 to 513 Euros in 1992. The average number of diagnostic examinations per patient decreased from 5.1 in 1976/77 to 2.4 in 1992. The length of hospital stay decreased from 11.5 to 2.7 days and the total costs of the diagnostic work-up decreased to one-third of the original, i.e. from 3423 Euros in 1976-77 to 1282 Euros in 1992. Conclusion: The costs of the radiological examinations rose, but the development of radiological technology simplified the diagnostic practice. The hospital stay drastically decreased. The total costs of diagnostic work-up per patient dropped to one-third of the baseline costs

  4. Comparison of the image quality between volumetric and conventional high-resolution CT with 64-slice row CT

    International Nuclear Information System (INIS)

    Gao Yanli; Zhang Lei; Zhao Xia; Ma Min; Zhai Renyou

    2008-01-01

    Objective: To compare the image quality between volumetric high-resolution CT (VHRCT) and conventional high-resolution CT (CHRCT), and investigate the feasibility of VHRCT. Methods: Catphan 412 phantom was scanned with protocols of CHRCT and VHRCT on a set of GE Lightspeed VCT. The spatial-resolution (LP/cm), noise (standard deviation in an ROI) and radiation close (CTDI) were recorded for each CT scan. Difference of noise between CHRCT and VHRCT were evaluated by paired t test. In clinical study, 32 patients were scanned with VHRCT and CHRCT protocols. The image quality of CHRCT and VHRCT was rated and compared. The quality difference between CHRCT and VHRCT was assessed by Wilcoxon paired signed rank sum test. Results: In phantom study, the in-plane spatial-resolution of both VHRCT and CHRCT was 11 LP/cm for axial images and 12 LP/cm for coronal reformatted images. The noise of VHRCT and CHRCT was (69.18±2.77)HU and (54.62±2.12) HU respectively (t=-15.929, P 0.05). The quality assessment scores of VHRCT coronal reformatted images and CHRCT coronal reformatted images were 3.05 and 1.88 respectively with significant difference (Z= -5.088, P<0.01). Conclusion: The image quality of VHRCT cross-sectional image is similar to that of CHRCT. Multiplanar images with high resolution of VHRCT are recommended. The radiation dose of VHRCT remains to be optimized. (authors)

  5. Value of micro-CT as an Investigative Tool for Osteochondritis Dissecans. A preliminary study with comparison to histology

    International Nuclear Information System (INIS)

    Mohr, A.; Bergmann, I.; Muhle, C.; Heller, M.; Heiss, C.; Schrader, C.; Roemer, F.W.; Lynch, J.A.; Genant, H.K.

    2003-01-01

    Purpose: To evaluate micro computed tomography (micro-CT) for the assessment of osteochondritis dissecans in comparison with histology. Material and Methods: Osteochondritis dissecans lesions of 3 patients were evaluated using micro-CT (0.125 mA, 40 keV, 60 m slice thickness, 60 m isotropic resolution, entire sample) and light microscopy (toluidine blue, 3-5 m slice thickness). The methods were compared regarding preparation time, detectability of tissue types and morphologic features of bone and cartilage. Results: Non-destructive micro-CT imaging of the entire sample was faster than histologic preparation of a single slice for light microscopy. Morphologic features of bone and cartilage could be imaged in a comparable way to histology. It was not possible to image cells or different tissue types of bone and cartilage with micro-CT. Conclusion: Micro-CT is a fast, non-destructive tool that may be a supplement or, if detailed histologic information is not necessary, an alternative to light microscopy for the investigation of osteochondritis dissecans. Osteochondritis dissecans micro-CT histology comparative investigation

  6. Xenon-enhanced CT using subtraction CT: Basic and preliminary clinical studies for comparison of its efficacy with that of dual-energy CT and ventilation SPECT/CT to assess regional ventilation and pulmonary functional loss in smokers

    Energy Technology Data Exchange (ETDEWEB)

    Ohno, Yoshiharu, E-mail: yosirad@kobe-u.ac.jp [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Yoshikawa, Takeshi [Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan); Advanced Biomedical Imaging Research Center, Kobe University Graduate School of Medicine, Kobe (Japan); Takenaka, Daisuke [Department of Radiology, Hyogo Cancer Center, Akashi (Japan); Fujisawa, Yasuko; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara (Japan); Kishida, Yuji; Seki, Shinichiro; Koyama, Hisanobu; Sugimura, Kazuro [Division of Radiology, Department of Radiology, Kobe University Graduate School of Medicine (Japan)

    2017-01-15

    Purpose: To prospectively and directly compare the capability for assessments of regional ventilation and pulmonary functional loss in smokers of xenon-ventilation CT obtained with the dual-energy CT (DE-CT) and subtraction CT (Sub-CT) Materials and methods: Twenty-three consecutive smokers (15 men and 8 women, mean age: 69.7 ± 8.7 years) underwent prospective unenhanced and xenon-enhanced CTs, the latter by Sub-CT and DE-CT methods, ventilation SPECT and pulmonary function tests. Sub-CT was generated from unenhanced and xenon-enhanced CT, and all co-registered SPECT/CT data were produced from SPECT and unenhanced CT data. For each method, regional ventilation was assessed by using a 11-point scoring system on a per-lobe basis. To determine the functional lung volume by each method, it was also calculated for individual sublets with a previously reported method. To determine inter-observer agreement for each method, ventilation defect assessment was evaluated by using the χ2 test with weighted kappa statistics. For evaluation of the efficacy of each method for pulmonary functional loss assessment, functional lung volume was correlated with%FEV{sub 1}. Results: Each inter-observer agreement was rated as substantial (Sub-CT: κ = 0.69, p < 0.0001; DE-CT: κ = 0.64, p < 0.0001; SPECT/CT: κ = 0.64, p < 0.0001). Functional lung volume for each method showed significant to good correlation with%FEV{sub 1} (Sub-CT: r = 0.72, p = 0.0001; DE-CT: r = 0.74, p < 0.0001; SPECT/CT: r = 0.66, p = 0.0006). Conclusion: Xenon-enhanced CT obtained by Sub-CT can be considered at least as efficacious as that obtained by DE-CT and SPECT/CT for assessment of ventilation abnormality and pulmonary functional loss in smokers.

  7. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O'Connell, Avice M; Conover, David L

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of MGD to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9 ± 4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4 ± 6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum–minimum) of MGD from dedicated breast CT was lower than

  8. Comparison of CT and anatomic pathological findings of the abdomen in HIV infection

    International Nuclear Information System (INIS)

    Tosch, U.; Witt, H.; Jautzke, G.; Ruf, B.

    1990-01-01

    In a retrospective study the results of abdominal computed tomography (CT) from 48 patients, who died of the complications of HIV infection, were compared with those obtained at autopsy. The CT diagnosis was confirmed at autopsy in 39 cases (81.3%). In nine patients CT results did not correlate with the postmortal findings. This was caused by lack of cooperation, cachexia and the time between the last CT study and the death of the patients. Nevertheless, CT with its standardised imaging planes is an important method for diagnosing and monitoring HIV-related diseases of the abdomen. (orig.) [de

  9. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2012-06-15

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 {mu}Sv), followed by AZ3000CT (332.4 {mu}Sv), Somatom Emotion 6 (199.38 {mu}Sv), and 3D eXaM (111.6 {mu}Sv); it was the lowest for Implagraphy (83.09 {mu}Sv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  10. Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

    International Nuclear Information System (INIS)

    Jeong, Dae Kyo; Lee, Sang Chul; Huh, Kyung Hoe; Yi, Won Jin; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. The effective dose was the highest for Somatom Sensation 10 (425.84 μSv), followed by AZ3000CT (332.4 μSv), Somatom Emotion 6 (199.38 μSv), and 3D eXaM (111.6 μSv); it was the lowest for Implagraphy (83.09 μSv). The CBCT showed significant variation in dose level with different device. The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

  11. Direct Determination of Lean Body Mass by CT in F-18 FDG PET/CT Studies: Comparison with Estimates Using Predictive Equations.

    Science.gov (United States)

    Kim, Chang Guhn; Kim, Woo Hyoung; Kim, Myoung Hyoun; Kim, Dae-Weung

    2013-06-01

    The purpose of this study was to estimate lean body mass (LBM) using CT (LBM CTs) and compare the results with LBM estimates of four different predictive equations (LBM PEs) to assess whether LBM CTs and LBM PEs can be used interchangeably for SUV normalization. Whole-body F-18 FDG PET/CT studies were conducted on 392 patients. LBM CT1 is modified adipose tissue-free body mass, and LBM CT2 is adipose tissue-free body mass. Four different PEs were used for comparison (LBM PE1-4). Agreement between the two measurement methods was assessed by Bland-Altman analysis. We calculated the difference between two methods (bias), the percentage of difference, and the limits of agreement, expressed as a percentage. For LBM CTs vs. LBM PEs, except LBM PE3, the ranges of biases and limits of agreement were -3.77 to 3.81 kg and 26.60-35.05 %, respectively, indicating the wide limits of agreement and differing magnitudes of bias. For LBM CTs vs. LBM PE3, LBM PE3 had wider limits of agreement and greater positive bias (44.28-46.19 % and 10.49 to 14.04 kg, respectively), showing unacceptably large discrepancies between LBM CTs and LBM PE3. This study demonstrated that there are substantial discrepancies between individual LBM CTs and LBM PEs, and this should be taken into account when LBM CTs and LBM PEs are used interchangeably between patients.

  12. Accuracy and reliability of different cone beam computed tomography (CBCT) devices for structural analysis of alveolar bone in comparison with multislice CT and micro-CT.

    Science.gov (United States)

    Van Dessel, Jeroen; Nicolielo, Laura Ferreira Pinheiro; Huang, Yan; Coudyzer, Walter; Salmon, Benjamin; Lambrichts, Ivo; Jacobs, Reinhilde

    The aim of this study was to assess whether cone beam computed tomography (CBCT) may be used for clinically reliable alveolar bone quality assessment in comparison to its clinical alternatives, multislice computed tomography and the gold standard (micro-CT). Six dentate mandibular bone samples were scanned with seven CBCT devices (ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170, Carestream 9300, Scanora 3D, I-CAT Next generation), one micro-CT scanner (SkyScan 1174) and one MSCT machine (Somatom Definition Flash) using two protocols (standard and high-resolution). MSCT and CBCT images were automatically spatially aligned on the micro-CT scan of the corresponding sample. A volume of interest was manually delineated on the micro-CT image and overlaid on the other scanning devices. Alveolar bone structures were automatically extracted using the adaptive thresholding algorithm. Based on the resulting binary images, an automatic 3D morphometric quantification was performed in a CT-Analyser (Bruker, Kontich, Belgium). The reliability and measurement errors were calculated for each modality compared to the gold standard micro-CT. Both MSCT and CBCT were associated with a clinically and statistically (P max, bone surface density -0.47 mm-1 min to 0.16 mm-1 max and trabecular thickness 0.15 mm min to 0.31 mm max) were significantly (P max and fractal dimension 0.08 min to 0.17 max) in all scanners compared to micro-CT. However, the structural pattern of the alveolar bone remained similar compared to that of the micro-CT for the ProMax 3D Max, NewTom GiANO, Cranex 3D, 3D Accuitomo 170 and Carestream 9300. On the other hand, the Scanora 3D, i-CAT Next Generation, standard and high-resolution MSCT displayed an overrated bone quantity and aberrant structural pattern compared to other scanning devices. The calculation of morphometric indices had an overall high reliability (intraclass correlation coefficient [ICC] 0.62 min to 0.99 max), except

  13. Comparison of dosimetry between PET/CT and PET alone using 11C-ITMM

    International Nuclear Information System (INIS)

    Ito, Kimiteru; Sakata, Muneyuki; Wagarsuma, Kei; Toyohara, Jun; Ishibashi, Kenji; Ishii, Kenji; Ishiwata, Kiichi; Oda, Keiichi

    2016-01-01

    We used a new tracer, N-[4-[6-(isopropylamino) pyrimidin-4-yl]-1,3-thiazol-2-yl]-4- 11 C-methoxy-N-methylbenzamide ( 11 C-ITMM), to compare radiation doses from positron emission tomography (PET)/computed tomography (CT) with previously published doses from PET alone. Twelve healthy volunteers [six males (mean age ± SD, 27.7 ± 6.7 years) and six females (31.8 ± 14.5 years)] in 12 examinations were recruited. Dose estimations from PET/CT were compared with those from PET alone. Regions of interest (ROIs) in PET/CT were delineated on the basis of low-dose CT (LD-CT) images acquired during PET/CT. Internal and external radiation doses were estimated using OLINDA/EXM 1.0 and CT-Expo software. The effective dose (ED) for 11 C-ITMM calculated from PET/CT was estimated to be 4.7 ± 0.5 μSv/MBq for the male subjects and 4.1 ± 0.7 μSv/MBq for the female subjects. The mean ED for 11 C-ITMM calculated from PET alone in a previous report was estimated to be 4.6 ± 0.3 μSv/MBq (males, n = 3). The ED values for 11 C-ITMM calculated from PET/CT in the male subjects were almost identical to those from PET alone. The absorbed doses (ADs) of the gallbladder, stomach, red bone marrow, and spleen calculated from PET/CT were significantly different from those calculated from PET alone. The EDs of 11 C-ITMM calculated from PET/CT were almost identical to those calculated from PET alone. The ADs in several organs calculated from PET/CT differed from those from PET alone. LD-CT images acquired during PET/CT may facilitate organ identification.

  14. Image quality comparison between single energy and dual energy CT protocols for hepatic imaging

    International Nuclear Information System (INIS)

    Yao, Yuan; Pelc, Norbert J.; Ng, Joshua M.; Megibow, Alec J.

    2016-01-01

    Purpose: Multi-detector computed tomography (MDCT) enables volumetric scans in a single breath hold and is clinically useful for hepatic imaging. For simple tasks, conventional single energy (SE) computed tomography (CT) images acquired at the optimal tube potential are known to have better quality than dual energy (DE) blended images. However, liver imaging is complex and often requires imaging of both structures containing iodinated contrast media, where atomic number differences are the primary contrast mechanism, and other structures, where density differences are the primary contrast mechanism. Hence it is conceivable that the broad spectrum used in a dual energy acquisition may be an advantage. In this work we are interested in comparing these two imaging strategies at equal-dose and more complex settings. Methods: We developed numerical anthropomorphic phantoms to mimic realistic clinical CT scans for medium size and large size patients. MDCT images based on the defined phantoms were simulated using various SE and DE protocols at pre- and post-contrast stages. For SE CT, images from 60 kVp through 140 with 10 kVp steps were considered; for DE CT, both 80/140 and 100/140 kVp scans were simulated and linearly blended at the optimal weights. To make a fair comparison, the mAs of each scan was adjusted to match the reference radiation dose (120 kVp, 200 mAs for medium size patients and 140 kVp, 400 mAs for large size patients). Contrast-to-noise ratio (CNR) of liver against other soft tissues was used to evaluate and compare the SE and DE protocols, and multiple pre- and post-contrasted liver-tissue pairs were used to define a composite CNR. To help validate the simulation results, we conducted a small clinical study. Eighty-five 120 kVp images and 81 blended 80/140 kVp images were collected and compared through both quantitative image quality analysis and an observer study. Results: In the simulation study, we found that the CNR of pre-contrast SE image mostly

  15. Comparison of computational to human observer detection for evaluation of CT low dose iterative reconstruction

    Science.gov (United States)

    Eck, Brendan; Fahmi, Rachid; Brown, Kevin M.; Raihani, Nilgoun; Wilson, David L.

    2014-03-01

    Model observers were created and compared to human observers for the detection of low contrast targets in computed tomography (CT) images reconstructed with an advanced, knowledge-based, iterative image reconstruction method for low x-ray dose imaging. A 5-channel Laguerre-Gauss Hotelling Observer (CHO) was used with internal noise added to the decision variable (DV) and/or channel outputs (CO). Models were defined by parameters: (k1) DV-noise with standard deviation (std) proportional to DV std; (k2) DV-noise with constant std; (k3) CO-noise with constant std across channels; and (k4) CO-noise in each channel with std proportional to CO variance. Four-alternative forced choice (4AFC) human observer studies were performed on sub-images extracted from phantom images with and without a "pin" target. Model parameters were estimated using maximum likelihood comparison to human probability correct (PC) data. PC in human and all model observers increased with dose, contrast, and size, and was much higher for advanced iterative reconstruction (IMR) as compared to filtered back projection (FBP). Detection in IMR was better than FPB at 1/3 dose, suggesting significant dose savings. Model(k1,k2,k3,k4) gave the best overall fit to humans across independent variables (dose, size, contrast, and reconstruction) at fixed display window. However Model(k1) performed better when considering model complexity using the Akaike information criterion. Model(k1) fit the extraordinary detectability difference between IMR and FBP, despite the different noise quality. It is anticipated that the model observer will predict results from iterative reconstruction methods having similar noise characteristics, enabling rapid comparison of methods.

  16. The diagnostic value of multiplanar reconstruction on MDCT colonography for the preoperative staging of colorectal cancer

    International Nuclear Information System (INIS)

    Jin, Kwang Nam; Kim, Se Hyung; Lee, Jae Young; Lee, Jeong Min; Han, Joon Koo; Choi, Byung Ihn; Shin, Kyung-Sook

    2006-01-01

    The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists' performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both A Z (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P 0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641-0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone. (orig.)

  17. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  18. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  19. Comparison between whole-body MRI and Fluorine-18-Fluorodeoxyglucose PET or PET/CT in oncology: a systematic review

    International Nuclear Information System (INIS)

    Ciliberto, Mario; Maggi, Fabio; Treglia, Giorgio; Padovano, Federico; Calandriello, Lucio; Giordano, Alessandro; Bonomo, Lorenzo

    2013-01-01

    The aim of the article is to systematically review published data about the comparison between positron emission tomography (PET) or PET/computed tomography (PET/CT) using Fluorine-18-Fluorodeoxyglucose (FDG) and whole-body magnetic resonance imaging (WB-MRI) in patients with different tumours. A comprehensive literature search of studies published in PubMed/MEDLINE, Scopus and Embase databases through April 2012 and regarding the comparison between FDG-PET or PET/CT and WB-MRI in patients with various tumours was carried out. Forty-four articles comprising 2287 patients were retrieved in full-text version, included and discussed in this systematic review. Several articles evaluated mixed tumours with both diagnostic methods. Concerning the specific tumour types, more evidence exists for lymphomas, bone tumours, head and neck tumours and lung tumours, whereas there is less evidence for other tumour types. Overall, based on the literature findings, WB-MRI seems to be a valid alternative method compared to PET/CT in oncology. Further larger prospective studies and in particular cost-effectiveness analysis comparing these two whole-body imaging techniques are needed to better assess the role of WB-MRI compared to FDG-PET or PET/CT in specific tumour types

  20. The diagnosis of cerebrospinal fluid hypovolemia. The comparison between CT myelography and RI cisternography

    International Nuclear Information System (INIS)

    Watanabe, Keisuke; Hashizume, Keiji; Inoue, Satoki; Fujiwara, Aki; Furuya, Hitoshi

    2008-01-01

    The comparison in the title is performed in cases with suspicious hypovolemia of cerebrospinal fluid (CSF) and its leak at the lumbar region is also examined in whiplash injury. Subjects are 25 cases (M 14/F 11, av. age 36.9 y) with traffic (13 cases), whiplash (4) and null (8) injuries. CT myelography (CTM) is conducted by injection of iotrolan through the lumbar puncturing needle to get 700 images of the whole spine of 1 mm slice thickness, which after animated, are observed visually. RI cisternography (RIC) is done immediately, 2 and 24 hr after injection of 10 MBq of diethylenetriamine pentaacetic acid (DTPA)-In through the puncturing needle. In 15 cases exhibiting positive RIC findings, CTM gives a positive leak at cervical and thoracic regions only in 2 cases and a false positive in other 13. In contrast, RIC fails to detect 2 cases of 4 with a leak at cervical and thoracic regions. Thus RIC is less reliable, and often observable RI accumulation at the lumbar area in RIC is not always a leak. (R.T.)

  1. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    International Nuclear Information System (INIS)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker; Floegel, Thomas; Kitzler, Hagen H.; Alexandrov, Andrei V.

    2016-01-01

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r s = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  2. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Floegel, Thomas [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Kitzler, Hagen H. [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Alexandrov, Andrei V. [The University of Tennessee Health Science Center, Department of Neurology, Memphis, TN (United States)

    2016-09-15

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r{sub s} = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  3. Multidetector CT enteroclysis: comparison of the reading performance for axial and coronal views

    International Nuclear Information System (INIS)

    Schmidt, Sabine; Chalaron, Marc; Schnyder, Pierre; Denys, Alban; Chevallier, Patrick; Bessoud, Bertrand; Verdun, Francis R.; Frascarolo, Philippe

    2005-01-01

    The purpose of this study was to compare the diagnostic performance of axial and coronal views in multidetector CT enteroclysis (MDCTE). We retrospectively evaluated 48 patients with pathological correlation investigated by MDCTE for small bowel disorders. After nasojejunal administration of 2 l of 5% methylcellulose axial arterial and venous acquisition of MDCTE was followed by coronal reconstructions using equal slice thicknesses of 2.5 mm with 2 mm increments. Spatial resolution of both planes was evaluated by phantom. Three radiologists independently read axial and coronal images concerning 12 pathological features. The interobserver agreement and time of reading was calculated. Sensitivity and specificity resulted from comparison with histopathology (n=39) or follow-up (n=9). Phantom study revealed higher spatial resolution for axial than coronal views, whatever reconstruction interval was used. However, spatial frequency always remained high. Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and intraperitoneal fluid (IPF), showed better interobserver agreement on axial than coronal views (BWT: 0.61 vs. 0.44; BWE: 0.56 vs. 0.5; IPF:0.53 vs. 0.43). The Wilcoxon signed-rank test revealed significantly higher sensitivity for axial than coronal views (P=0.0453); the time of reading was significantly shorter for the latter (P=0.0146). The diagnostic value of axial slices is superior to coronal reconstructions despite the reduced data volume and display of the physiological course of bowel loops on the coronal plane. (orig.)

  4. Demonstration of infective endocarditis by cardiac CT and transoesophageal echocardiography: comparison with intra-operative findings.

    Science.gov (United States)

    Koo, Hyun Jung; Yang, Dong Hyun; Kang, Joon-Won; Lee, Joo Yeon; Kim, Dae-Hee; Song, Jong-Min; Kang, Duk-Hyun; Song, Jae-Kwan; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae-Won; Lim, Tae-Hwan

    2018-02-01

    We aimed to compare imaging findings of infective endocarditis between computed tomography (CT) and transoesophageal echocardiography (TEE) using surgical inspection as a reference standard. Forty-nine patients (aged 54 ± 17 years, 69% men) who underwent pre-operative CT and TEE for infective endocarditis were included. Twelve of these patients had prosthetic valve endocarditis. Imaging findings of infective endocarditis were classified as vegetation, leaflet perforation, abscess/pseudoaneurysm, and paravalvular leakage. Diagnostic performances of CT and TEE were evaluated using surgical inspection as a reference standard. Interobserver agreements for CT findings were obtained using Cohen's κ test. The detection rates of infective endocarditis per patient with CT and TEE were 93.9% (46/49) and 95.9% (47/49), respectively. In per-imaging analysis, the sensitivities of CT and TEE were not significantly different for both native and prosthetic valve infective endocarditis (sensitivity: vegetation, 100% in TEE and 90.9% in CT; leaflet perforation, 87.5% in TEE and 50.0% in CT; abscess/pseudoaneurysm, 40.0% in TEE and 60.0% in CT; paravalvular leakage, 100% in TEE and 50.0% in CT). Interobserver agreements for CT findings were substantial or excellent (0.79-0.88). Cardiac CT can accurately demonstrate infective endocarditis in pre-operative patients with a similar diagnostic accuracy to TEE. The interobserver agreements for the CT findings of infective endocarditis were excellent. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  5. SU-F-J-88: Comparison of Two Deformable Image Registration Algorithms for CT-To-CT Contour Propagation

    International Nuclear Information System (INIS)

    Gopal, A; Xu, H; Chen, S

    2016-01-01

    Purpose: To compare the contour propagation accuracy of two deformable image registration (DIR) algorithms in the Raystation treatment planning system – the “Hybrid” algorithm based on image intensities and anatomical information; and the “Biomechanical” algorithm based on linear anatomical elasticity and finite element modeling. Methods: Both DIR algorithms were used for CT-to-CT deformation for 20 lung radiation therapy patients that underwent treatment plan revisions. Deformation accuracy was evaluated using landmark tracking to measure the target registration error (TRE) and inverse consistency error (ICE). The deformed contours were also evaluated against physician drawn contours using Dice similarity coefficients (DSC). Contour propagation was qualitatively assessed using a visual quality score assigned by physicians, and a refinement quality score (0 0.9 for lungs, > 0.85 for heart, > 0.8 for liver) and similar qualitative assessments (VQS 0.75 for lungs). When anatomical structures were used to control the deformation, the DSC improved more significantly for the biomechanical DIR compared to the hybrid DIR, while the VQS and RQS improved only for the controlling structures. However, while the inclusion of controlling structures improved the TRE for the hybrid DIR, it increased the TRE for the biomechanical DIR. Conclusion: The hybrid DIR was found to perform slightly better than the biomechanical DIR based on lower TRE while the DSC, VQS, and RQS studies yielded comparable results for both. The use of controlling structures showed considerable improvement in the hybrid DIR results and is recommended for clinical use in contour propagation.

  6. Comparison of two imaging protocols for acute stroke: unenhanced cranial CT versus a multimodality cranial CT protocol with perfusion imaging

    International Nuclear Information System (INIS)

    Langer, R. D.; Gorkom, K. Neidl van.; Kaabi, Ho Al.; Torab, F.; Czechowski, J.; Nagi, M.; Ashish, G. M.

    2007-01-01

    Full text: The aim of the study was to validate a multimodality cranial computed tomography (CCT) protocol for patients with acute stroke in the United Arab Emirates as a basic imaging procedure for a stroke unit. Therefore, a comparative study was conducted between two groups: retrospective, historical group 1 with early unenhanced CCT and prospective group 2 undergoing a multimodality CCT protocol. Follow-up unenhanced CCT >48 h served as gold standard in both groups. Group 1: Early unenhanced CCT of 50 patients were evaluated retrospectively, using Alberta Stroke Program Early CT Score, and compared with the definite infarction on follow-up CCT. Group 2: 50 patients underwent multimodality CCT (unenhanced CCT, perfusion studies: cerebral blood flow, cerebral blood volume, mean transit time and CT angiography) <8 h after clinical onset and follow-up studies. Modified National Institute of Health Stroke Scale was used clinically in both groups. Group 1 showed 38 men, 12 women, clinical onset 2-8 h before CCT and modified National Institute of Health Stroke Scale 0-28. Group 2 included 38 men, 12 women, onset 3-8 h before CCT, modified National Institute of Health Stroke Scale 0-28. Sensitivity was 58.3% in group 1 and 84.2% in group 2. Computed tomography angiography detected nine intracranial occlusions/stenoses. The higher sensitivity of the multimodality CCT protocol justifies its use as a basic diagnostic tool for the set-up of a first-stroke unit in the United Arab Emirates

  7. SU-F-J-88: Comparison of Two Deformable Image Registration Algorithms for CT-To-CT Contour Propagation

    Energy Technology Data Exchange (ETDEWEB)

    Gopal, A; Xu, H; Chen, S [University of Maryland School of Medicine, Columbia, MD (United States)

    2016-06-15

    Purpose: To compare the contour propagation accuracy of two deformable image registration (DIR) algorithms in the Raystation treatment planning system – the “Hybrid” algorithm based on image intensities and anatomical information; and the “Biomechanical” algorithm based on linear anatomical elasticity and finite element modeling. Methods: Both DIR algorithms were used for CT-to-CT deformation for 20 lung radiation therapy patients that underwent treatment plan revisions. Deformation accuracy was evaluated using landmark tracking to measure the target registration error (TRE) and inverse consistency error (ICE). The deformed contours were also evaluated against physician drawn contours using Dice similarity coefficients (DSC). Contour propagation was qualitatively assessed using a visual quality score assigned by physicians, and a refinement quality score (0 0.9 for lungs, > 0.85 for heart, > 0.8 for liver) and similar qualitative assessments (VQS < 0.35, RQS > 0.75 for lungs). When anatomical structures were used to control the deformation, the DSC improved more significantly for the biomechanical DIR compared to the hybrid DIR, while the VQS and RQS improved only for the controlling structures. However, while the inclusion of controlling structures improved the TRE for the hybrid DIR, it increased the TRE for the biomechanical DIR. Conclusion: The hybrid DIR was found to perform slightly better than the biomechanical DIR based on lower TRE while the DSC, VQS, and RQS studies yielded comparable results for both. The use of controlling structures showed considerable improvement in the hybrid DIR results and is recommended for clinical use in

  8. Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods

    Science.gov (United States)

    Marchant, T. E.; Joshi, K. D.; Moore, C. J.

    2018-03-01

    Radiotherapy dose calculations based on cone-beam CT (CBCT) images can be inaccurate due to unreliable Hounsfield units (HU) in the CBCT. Deformable image registration of planning CT images to CBCT, and direct correction of CBCT image values are two methods proposed to allow heterogeneity corrected dose calculations based on CBCT. In this paper we compare the accuracy and robustness of these two approaches. CBCT images for 44 patients were used including pelvis, lung and head & neck sites. CBCT HU were corrected using a ‘shading correction’ algorithm and via deformable registration of planning CT to CBCT using either Elastix or Niftyreg. Radiotherapy dose distributions were re-calculated with heterogeneity correction based on the corrected CBCT and several relevant dose metrics for target and OAR volumes were calculated. Accuracy of CBCT based dose metrics was determined using an ‘override ratio’ method where the ratio of the dose metric to that calculated on a bulk-density assigned version of the same image is assumed to be constant for each patient, allowing comparison to the patient’s planning CT as a gold standard. Similar performance is achieved by shading corrected CBCT and both deformable registration algorithms, with mean and standard deviation of dose metric error less than 1% for all sites studied. For lung images, use of deformed CT leads to slightly larger standard deviation of dose metric error than shading corrected CBCT with more dose metric errors greater than 2% observed (7% versus 1%).

  9. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  10. Staging of untreated nasopharyngeal carcinoma with PET/CT: comparison with conventional imaging work-up

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Chan, Sheng-Chieh; Yen, Tzu-Chen; Liu, Feng-Yuan; Chang, Joseph Tung-Chieh; Fan, Kang-Hsing; Liao, Chun-Ta; Ko, Sheung-Fat; Chin, Shu-Chyn; Hsu, Cheng-Lung

    2009-01-01

    We prospectively compared PET/CT and conventional imaging for initial staging of nasopharyngeal carcinoma (NPC). A total of 111 patients with histologically proven NPC were investigated with PET/CT and conventional imaging (head-and-neck MRI, chest X-ray, abdominal ultrasound, and bone scan) before treatment. The respective findings were reviewed independently and then compared with each other. With regard to T staging, PET/CT showed a discrepancy with head-and-neck MRI in 36 (32.4%) of the study subjects. With regard to N staging, PET/CT showed a discrepancy with head-and-neck MRI in 15 (13.5%) patients. Among the discordant cases, MRI was superior in demonstrating tumor involvement in the parapharyngeal space, skull base, intracranial area, sphenoid sinus, and retropharyngeal nodes while PET/CT was superior in demonstrating neck nodal metastasis. PET/CT disclosed 13 of 16 patients with distant malignancy compared with four patients disclosed by conventional imaging work-up. The false-positive rate of PET/CT was 18.8%. PET/CT correctly modified M staging in eight patients (7.2%) and disclosed a second primary lung malignancy in one patient (0.9%). In NPC patients, MRI appears to be superior to PET/CT for the assessment of locoregional invasion and retropharyngeal nodal metastasis. PET/CT is more accurate than MRI for determining cervical nodal metastasis and should be the better reference for the neck status. PET/CT has an acceptable diagnostic yield and a low false-positive rate for the detection of distant malignancy and can replace conventional work-up to this aim. PET/CT and head-and-neck MRI are suggested for the initial staging of NPC patients. (orig.)

  11. Hypothalamic-pituitary dwarfism: Comparison between MR imaging and CT findings

    International Nuclear Information System (INIS)

    Maghnie, M.; Larizza, D.; Severi, F.; Triulzi, F.; Scotti, G.; Beluffi, G.; Cecchini, A.

    1990-01-01

    Magnetic Resonance (MR) imaging was carried out on 33 patients with idiopathic growth hormone deficiency, in 22 of whom CT scan had been carried out previously. Twenty-one patients presented some complications at birth. Both MR and CT were positive in the evaluation of the sella. MR imaging exhibited a higher degree of accuracy than CT in the evaluation of pituitary gland, pituitary stalk and brain anomalies. (orig.)

  12. Volume-artifact reduction modality by helical CT of the anterior, middle and posterior carnial fossae. Comparison with conventional CT; Volumen-Artefakt-Reduktionstechnik mittels Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube. Vergleich mit der konventionellen kranialen CT

    Energy Technology Data Exchange (ETDEWEB)

    Dorenbeck, U.; Finkenzeller, T.; Hill, K.; Feuerbach, S.; Link, J. [Regensburg Univ. (Germany). Inst. fuer Roentgendiagnostik

    2000-04-01

    Purpose: The object of this study was to determine the extent to which a new volume-artifact reduction (VAR) modality using helical CT was able to reduce artifacts in the anterior, middle and posterior fossae in comparison with conventional CT (sequential mode). Methods: In a prospective, randomized trial, 50 patients underwent helical CT (VAR) and 50 underwent sequential CT. The results were evaluated by three radiologists; influences on image quality where scaled between 1 (no artifact) and 4 (not assessable). Eight regions of the anterior, middle and posterior fossae were evaluated. Results: On average, artifacts were scaled at 2.5 in helical CT (VAR) and 3.1 in conventional CT. Significant differences were seen at the eyeball, anterior to the petrosol bone, at the internal occipital crest, and at the level of the transverse sinus (p<0.005). Conclusions: Helical CT with the VAR modality is superior to conventional, sequential CT in the area of the anterior, middle and posterior fossae. (orig.) [German] Ziel: Das Ziel dieser Studie war herauszufinden, inwieweit ein neuer Volumen-Artefakt-Reduktionsmodus (VAR) im Spiral-CT in der vorderen, mittleren und hinteren Schaedelgrube gegenueber der Einzelschicht-CT zu einer Artefaktverringerung beitragen kann. Methoden: In einer prospektiven randomisierten Studie wurden 50 Untersuchungen mit Spiral-CT und 50 mit Einzelschicht-CT bezueglich Artefakten verglichen. Die Auswertung erfolgte durch drei Radiologen, die Bildqualitaet wurde in einer Skala zwischen 1 (kein Artefakt) und 4 (Beurteilung der Region wegen Artefakten nicht moeglich) angegeben. Acht anatomische Regionen in der vorderen, mittleren und hinteren Schaedelgrube wurden auf Beeintraechtigung durch Artefakte untersucht. Ergebnisse: Im Durchschnitt betrug die Bewertung fuer die Artefaktbeeintraechtigung beim Spiral-CT (VAR) 2,5 gegenueber 3,1 bei der Einzelschicht-CT. Der VAR-Modus ermoeglichte in der mittleren und hinteren Schaedelgrube sowie im Balbus oculi

  13. Utility of bolus dynamic CT for the detection of hypervascular malignant hepatic tumors. Mainly referring to the comparison with delayed phase contrast-enhanced CT

    International Nuclear Information System (INIS)

    Matsuda, Hiromichi; Abe, Kimihiko; Freeny, P.C.

    1996-01-01

    In order to analyze the usefulness of dynamic contrast-enhanced CT, 84 patients who had hepatocellular carcinoma or suspected hypervascular metastases were studied with conventional incremental dynamic CT (CID-CT) or double helical CT (DH-CT). Delayed phase contrast-enhanced CT studies were consecutively performed in all patients. Thirty-six of 84 patients had malignant hepatic neoplasms; six had hepatocellular carcinoma and 30 had metastatic tumors. At first, the detectability of hepatic lesions was evaluated with bolus dynamic CT and delayed phase CT. Dynamic CT has detected more lesions than delayed CT. Some hepatic lesions described as isodensity were missed on CID-CT. Therefore, delayed phase CT cannot be eliminated when CID-CT is performed. Secondly, hepatic lesion detectability with CID-CT was compared with that of DH-CT. DH-CT did not miss the hepatic lesions picked up by delayed phase CT and was expected to provide excellent detectability of hypervascular hepatic neoplasms. In addition, first helical CT showed most hepatic lesions as areas of obvious hyperdensity, while CID-CT did not show their correct vascularities. So-called hypervascular hepatic tumors, however, were not always hypervascular and were demonstrated as areas of iso-hypodensity even on initial helical scanning. Second helical CT was useful to detect these so-called hypervascular, but actually hypovascular lesions. In conclusion, dynamic CT was helpful in detecting hypervascular hepatic malignant neoplasms, and DH-CT was more accurate than-CID-CT for the detection of hepatic lesions and the evaluation of vascular lesion. (author)

  14. A short comparison between mT2 and mCT

    International Nuclear Information System (INIS)

    Serna, Mario

    2008-01-01

    We compare m T2 with m CT ; both are kinematic variables designed to find relationships between masses of pair-produced new states with symmetric decay chains. We find that for massless visible particles m CT equals m T2 in a particular limit. We identify advantages and disadvantages to the use of each variable. Tovey's paper on m CT also introduced a powerful concept of extracting mass information from an analysis at intermediate stages of a symmetric decay chain. We suggest that m T2 is a better tool for performing this analysis than m CT due to m T2 's better properties under initial state radiation.

  15. Detection and preoperative staging of carcinoma of the cervix: Comparison between MR imaging and CT

    International Nuclear Information System (INIS)

    Mayr, B.; Schmidt, H.; Baieri, P.; Scheidel, P.; Meier, W.; Schramm, T.

    1986-01-01

    Twenty-four patients with carcinoma of the cervix were examined preoperatively by MR imaging and CT. In all patients histopathologic confirmation was available for specimens obtained either by radical hysterectomy or at staging laparotomy. MR imaging was equivalent to contrast CT in the detection and evaluation of tumor extension in the cervix. Tumor extension to the parametria and pelvic wall was difficult to evaluate on both modalities, as neither had a higher accuracy than pelvic examination conducted under anesthesia. Nodal staging was nearly equivalent on MR imaging and CT. In the detection and staging of carcinoma of the cervix, MR imaged proved to be as good as CT with contrast agent enhancement

  16. Comparison of CT and CMR for detection and quantification of carotid artery calcification

    DEFF Research Database (Denmark)

    Mujaj, Blerim; Lorza, Andrés M. Arias; van Engelen, Arna

    2017-01-01

    interscan interval: 4.9 ± 1.2 years). We investigated the correlation between the amount of calcification measured on CT and CMR using Spearman's correlation coefficient, Bland-Altman plots, and linear regression. In addition, using logistic regression modeling, we assessed the association of CT and CMR...... larger. Finally, calcification volume assessed with either imaging modality was associated with a history of stroke with similar effect estimates (odds ratio (OR) per 1-SD increase in calcification volume: 1.52 (95% CI:1.00;2.30) for CT, and 1.47 (95% CI:1.01;2.14) for CMR. CONCLUSION: CT based and CMR...

  17. 18F-FDG PET/CT in paediatric lymphoma: comparison with conventional imaging

    International Nuclear Information System (INIS)

    London, Kevin; Cross, Siobhan; Dalla-Pozza, Luciano; Onikul, Ella; Howman-Giles, Robert

    2011-01-01

    In children with Hodgkin's disease and non-Hodgkin's lymphoma, the ability of 18 F-fluoro-2-deoxy-D-glucose PET/CT and conventional imaging (CI) to detect malignant lesions and predict poor lesion response to therapy was assessed and compared. A retrospective review of findings reported on PET/CT and CI was performed using a lesion-based analysis of 16 lymph node and 8 extra-nodal regions. Lesions were defined by histopathological findings or follow-up > 6 months. The study included 209 PET/CT scans with a valid CI comparator. A total of 5,014 regions (3,342 lymph node, 1,672 extra-nodal) were analysed. PET/CT performed significantly better than CI in the detection of malignant lesions with sensitivity and specificity of 95.9 and 99.7% compared to 70.1 and 99.0%, respectively. For predicting poor lesion response to therapy, PET/CT had fewer false-positive lesions than CI. The specificity for predicting poor lesion response to treatment for PET/CT was 99.2% compared to 96.9% for CI. PET/CT was the correct modality in 86% of lesions with discordant findings. PET/CT is more accurate than CI in detecting malignant lesions in childhood lymphoma and in predicting poor lesion response to treatment. In lesions with discordant findings, PET/CT results are more likely to be correct. (orig.)

  18. {sup 68}Ga-DOTATATE PET/CT in recurrent medullary thyroid carcinoma: a lesion-by-lesion comparison with {sup 111}In-octreotide SPECT/CT and conventional imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yamaga, Lilian Yuri Itaya; Cunha, Marcelo L.; Campos Neto, Guilherme C.; Garcia, Marcio R.T.; Wagner, Jairo; Funari, Marcelo B.G. [Hospital Israelita Albert Einstein, Imaging Department, Sao Paulo (Brazil); Yang, Ji H.; Camacho, Cleber P. [Universidade Federal de Sao Paulo, Multiple Neoplasia Outpatiet Clinic, Sao Paulo (Brazil)

    2017-09-15

    The aim of this study was to prospectively compare the detection rate of {sup 68}Ga-DOTATATE PET-CT with {sup 111}In-octreotide SPECT-CT and conventional imaging (CI) in medullary thyroid carcinoma (MTC) patients with increased calcitonin (Ctn) levels but negative CI after thyroidectomy. Fifteen patients with raised Ctn levels and/or CI evidence of recurrence underwent {sup 68}Ga-DOTATATE PET-CT, {sup 111}In-octreotide SPECT-CT and CI. Histopathology, CI and biochemical/clinical/imaging follow-up were used as the reference standard. PET/CT, SPECT/CT and CI were compared in a lesion-based and organ-based analysis. PET/CT evidenced recurrence in 14 of 15 patients. There were 13 true positive (TP), 1 true negative (TN), 1 false positive (FP) and no false negative (FN) cases, resulting in a sensitivity and accuracy of 100% and 93%. SPECT/CT was positive in 6 of 15 cases. There were 6 TP, 2 TN, 7 FN and no FP cases, resulting in a sensitivity of 46% and accuracy of 53%. CI procedures detected tumor lesions in 14 of 15 patients. There were 13 TP, 1TN, 1 FP and no FN cases with a sensitivity of 100% and accuracy of 93%. A significantly higher number of lesions was detected by PET/CT (112 lesions, p = 0.005) and CI (109 lesions, p = 0.005) in comparison to SPECT/CT (16 lesions). There was no significant difference between PET/CT and CI for the total number of detected lesions (p = 0.734). PET/CT detected more lesions than SPECT/CT regardless of the organ. PET/CT detected more bone lesions but missed some neck nodal metastases evidenced by CI. The number of lesions per region demonstrated by PET/CT and CI were similar in the other sites. {sup 68}Ga-DOTATATE PET/CT is superior to {sup 111}In-octreotide SPECT/CT for the detection of recurrent MTC demonstrating a significantly higher number of lesions. {sup 68}Ga-DOTATATE PET/CT showed a superior detection rate compared to CI in demonstrating bone metastases. (orig.)

  19. CT-guided percutaneous lung biopsy: Comparison of conventional CT fluoroscopy to CT fluoroscopy with electromagnetic navigation system in 60 consecutive patients

    Energy Technology Data Exchange (ETDEWEB)

    Grand, David Justin, E-mail: dgrand@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Atalay, Michael A., E-mail: matalay@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Cronan, John J., E-mail: cronan@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Mayo-Smith, William W., E-mail: wmayo-smith@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States); Dupuy, Damian E., E-mail: ddupuy@lifespan.org [Department of Diagnostic Imaging, Warren Alpert School of Medicine, Brown University, Providence, RI 02903 (United States)

    2011-08-15

    Purpose: To determine if use of an electromagnetic navigation system (EMN) decreases radiation dose and procedure time of CT fluoroscopy guided lung biopsy in lesions smaller than 2.5 cm. Materials/methods: 86 consecutive patients with small lung masses (<2.5 cm) were approached. 60 consented and were randomized to undergo biopsy with CT fluoroscopy (CTF) (34 patients) or EMN (26 patients). Technical failure required conversion to CTF in 8/26 EMN patients; 18 patients completed biopsy with EMN. Numerous biopsy parameters were compared as described below. Results: Average fluoroscopy time using CTF was 28.2 s compared to 35.0 s for EMN (p = 0.1). Average radiation dose was 117 mGy using CTF and 123 mGy for EMN (p = 0.7). Average number of needle repositions was 3.7 for CTF and 4.4 for EMN (p = 0.4). Average procedure time was 15 min for CTF and 20 min for EMN (p = 0.01). There were 7 pneumothoracesin the CTF group and 6 pneumothoraces in the EMN group (p = 0.7). One pneumothorax in the CTF group and 3 pneumothoraces in the EMN group required chest tube placement (p = 0.1). One pneumothorax patient in each group required hospital admission. Diagnostic specimens were obtained in 31/34 patients in the CTF group and 22/26 patients in the EMN group (p = 0.4). Conclusions: EMN was not statistically different than CTF for fluoroscopy time, radiation dose, number of needle repositions, incidence of pneumothorax, need for chest tube, or diagnostic yield. Procedure time was increased with EMN.

  20. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    Energy Technology Data Exchange (ETDEWEB)

    Cornelis, F.; Takaki, H. [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States); Laskhmanan, M. [Perfint Healthcare Inc (India); Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G., E-mail: srimaths@mskcc.org [Memorial Sloan-Kettering Cancer Center, Interventional Radiology Service, Department of Radiology (United States)

    2015-10-15

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy.

  1. Comparison of CT Fluoroscopy-Guided Manual and CT-Guided Robotic Positioning System for In Vivo Needle Placements in Swine Liver

    International Nuclear Information System (INIS)

    Cornelis, F.; Takaki, H.; Laskhmanan, M.; Durack, J. C.; Erinjeri, J. P.; Getrajdman, G. I.; Maybody, M.; Sofocleous, C. T.; Solomon, S. B.; Srimathveeravalli, G.

    2015-01-01

    PurposeTo compare CT fluoroscopy-guided manual and CT-guided robotic positioning system (RPS)-assisted needle placement by experienced IR physicians to targets in swine liver.Materials and MethodsManual and RPS-assisted needle placement was performed by six experienced IR physicians to four 5 mm fiducial seeds placed in swine liver (n = 6). Placement performance was assessed for placement accuracy, procedure time, number of confirmatory scans, needle manipulations, and procedure radiation dose. Intra-modality difference in performance for each physician was assessed using paired t test. Inter-physician performance variation for each modality was analyzed using Kruskal–Wallis test.ResultsPaired comparison of manual and RPS-assisted placements to a target by the same physician indicated accuracy outcomes was not statistically different (manual: 4.53 mm; RPS: 4.66 mm; p = 0.41), but manual placement resulted in higher total radiation dose (manual: 1075.77 mGy/cm; RPS: 636.4 mGy/cm; p = 0.03), required more confirmation scans (manual: 6.6; RPS: 1.6; p < 0.0001) and needle manipulations (manual: 4.6; RPS: 0.4; p < 0.0001). Procedure time for RPS was longer than manual placement (manual: 6.12 min; RPS: 9.7 min; p = 0.0003). Comparison of inter-physician performance during manual placement indicated significant differences in the time taken to complete placements (p = 0.008) and number of repositions (p = 0.04) but not in other study measures (p > 0.05). Comparison of inter-physician performance during RPS-assisted placement suggested statistically significant differences in procedure time (p = 0.02) and not in other study measures (p > 0.05).ConclusionsCT-guided RPS-assisted needle placement reduced radiation dose, number of confirmatory scans, and needle manipulations when compared to manual needle placement by experienced IR physicians, with equivalent accuracy

  2. Comparison of plain radiography and CT in postoperative evaluation of ankle fractures

    International Nuclear Information System (INIS)

    Chen, Y.; Zhang, K.; Qiang, M.; Li, H.; Dai, H.

    2015-01-01

    Aim: To compare postoperative plain radiographs with computed tomography (CT) post-processing images in evaluating the quality of anatomical reduction and internal fixation of ankle fractures. Materials and methods: A total of 168 patients who sustained closed ankle fracture and were treated with open reduction and internal fixation in East Hospital were reviewed. Postoperative plain radiographs and CT post-processing images were evaluated. The observation was performed under volume-rendering mode and multiplanar reconstruction mode. The assessment was performed by two independent orthopaedic surgeons. The inter- and intra-observer variations were analysed by kappa statistics. The differences between plain radiographs and CT post-processing images were compared using χ 2 test (McNemar's test). Results: Inter- and intra-observer agreement was almost perfect (0.813–1.000) using CT post-processing images, which was higher than that using plain radiographs (0.323–0.848). More non-anatomical reduction could be recognised in the supination–external rotation (SER), supination–adduction (SAD), pronation–external rotation (PER), and overall groups (p<0.05) and more poor internal fixation could be recognised in the SER, SAD, and overall groups (p<0.05) using CT post-processing images than using radiographs. Conclusion: More residual articular step, fracture fragment displacement, and poor internal fixation could be detected by CT post-processing images than plain radiographs. -- Highlights: •We compared postoperative X-rays with CT images in ankle fractures. •The evaluation agreement using CT images was higher than X-rays. •CT images detect more residual articular steps than X-rays. •CT images detect more fracture fragment displacement than X-rays. •CT images detect more poor internal fixation than X-rays

  3. Cost-effectiveness of computed tomographic colonography screening for colorectal cancer in the medicare population

    NARCIS (Netherlands)

    A.B. Knudsen (Amy); I. Lansdorp-Vogelaar (Iris); C.M. Rutter (Carolyn); J.E. Savarino (James); M. van Ballegooijen (Marjolein); K.M. Kuntz (Karen); A. Zauber (Ann)

    2010-01-01

    textabstractBackground The Centers for Medicare and Medicaid Services (CMS) considered whether to reimburse computed tomographic colonography (CTC) for colorectal cancer screening of Medicare enrollees. To help inform its decision, we evaluated the reimbursement rate at which CTC screening could be

  4. Combined Fluoroscopy- and CT-Guided Transthoracic Needle Biopsy Using a C-Arm Cone-Beam CT System: Comparison with Fluoroscopy-Guided Biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Joo Yeon; Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee [School of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    2011-02-15

    The aim of this study was to evaluate the usefulness of combined fluoroscopy- and CT-guided transthoracic needle biopsy (FC-TNB) using a cone beam CT system in comparison to fluoroscopy-guided TNB (F-TNB). We retrospectively evaluated 74 FC-TNB cases (group A) and 97 F-TNB cases (group B) to compare their respective diagnostic accuracies according to the size and depth of the lesion, as well as complications, procedure time, and radiation dose. The sensitivity for malignancy and diagnostic accuracy for small (< 30 mm in size) and deep ({>=} 50 mm in depth) lesions were higher in group A (91% and 94%, 92% and 94%) than in group B (73% and 81%, 84% and 88%), however not statistically significant (p > 0.05). Concerning lesions {>=} 30 mm in size and < 50 mm in depth, both groups displayed similar results (group A, 91% and 92%, 80% and 87%: group B, 90% and 92%, 86% and 90%). Pneumothorax occurred 26% of the time in group A and 14% for group B. The mean procedure time and patient skin dose were significantly higher in group A (13.6 {+-} 4.0 minutes, 157.1 {+-} 76.5 mGy) than in group B (9.0 {+-} 3.5 minutes, 21.9 {+-} 15.2 mGy) (p < 0.05). Combined fluoroscopy- and CT-guided TNB allows the biopsy of small (< 30 mm) and deep lesions ({>=} 50 mm) with high diagnostic accuracy and short procedure times, whereas F-TNB is still a useful method for large and superficial lesions with a low radiation dose

  5. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    Energy Technology Data Exchange (ETDEWEB)

    Ciet, Pierluigi [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands); Serra, Goffredo; Catalano, Carlo [University of Rome ' ' Sapienza' ' , Radiology, Rome (Italy); Bertolo, Silvia; Morana, Giovanni [General Hospital Ca' Foncello, Radiology Department, Treviso (Italy); Spronk, Sandra [Erasmus MC, Radiology, Rotterdam (Netherlands); Erasmus MC, Epidemiology, Rotterdam (Netherlands); Ros, Mirco [Ca' Foncello Hospital, Pediatrics, Treviso (Italy); Fraioli, Francesco [University College London (UCL), Institute of Nuclear Medicine, London (United Kingdom); Quattrucci, Serena [University of Rome Sapienza, Pediatrics, Rome (Italy); Assael, M.B. [Azienda Ospedaliera di Verona, Verona CF Center, Verona (Italy); Pomerri, Fabio [University of Padova, Department of Medicine-DIMED, Padova (Italy); Tiddens, Harm A.W.M. [Sophia Children' s Hospital, Pediatric Pulmonology Erasmus MC, Rotterdam (Netherlands); Erasmus MC, Radiology, Rotterdam (Netherlands)

    2016-03-15

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  6. A study of long boone measurement by CT scanogram - Comparison with spot scanogram -

    International Nuclear Information System (INIS)

    Suh, Chang Hae; Kang, Heung Sik; Jung, Jin Wook; Yeon, Kyung Mo

    1987-01-01

    CT scanogram is a new technique for measuring leg length discrepancy and has many advantage as compared with conventional spot scanogram. 30 dried bones were measured by direct measurement, spot scanogram and CT scanogram. Accuracy of CT scanogram was compared with spot scanogram. For evaluation of systemic error of CT, steel rulers and dried bones were measured at two different window settings. Decentering error in spot scanogram was measured by using dried bones, and 180 spots of 30 clinical cases of Beli-thompson studies were reviewed for evaluation of incidence and degree of decentering. The results of measurements of CT and spot scanogram in ideal position and technique were equivalent to those of direct measurements. But in spot scanogram, significant errors were noted in flexion status and decentered film. 54 spot (42.9%) of 30 clinical cases were decentered more than 1 cm. In CT scanogram, decentering error was completely excluded and shortening due to flexion deformity was overcomed by lateral scanogram. CT scanogram is a simple and accurate method for leg length measurement. Thus we recommend CT scanogram as a routine use for evaluation of leg length discrepancy.

  7. Usefulness of preoperative three dimensional CT in laparoscopic cholecystectomy. Especially, its comparison to ERC

    International Nuclear Information System (INIS)

    Machida, Hiromichi; Nakaya, Yuzou; Kojima, Kojirou

    1996-01-01

    We studied the usefulness of three dimensional helical CT (3D-CT) combined with drip infusion cholangiography for determining the application of laparoscopic cholecystectomy (LC) and evaluating the cholecyst severity. The subjects were 56 patients who underwent LC with preoperative 3D-CT. Particularly, in 42 patients undergoing endoscopic retrograde cholangiography (ERC) and 3D-CT simultaneously, the results with both methods were compared. The detection rates of the original site, forward and backward direction, and left and right direction in the confluence form of the cystic duct by means of 3D-CT versus ERC were 100% vs. 92.9% 92.9% vs. 71.4%, and 92.9% vs. 88.1%, respectively. Abnormal biliary distribution was visualized in 5 cases and all of them were depicted by 3D-CT. The 3D-CT was superior to ERC in terms of X-ray dose and cost. These results indicate the usefulness of 3D-CT as a LC preoperative examination. (author)

  8. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  9. Paediatric urological investigations - dose comparison between urology-related and CT irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Page, Mark; Florescu, Cosmin [Southern Health, Diagnostic Imaging, Melbourne (Australia); Johnstone, Lilian [Monash Children' s Hospital, Department of Paediatrics, Melbourne (Australia); Habteslassie, Daniel [Monash University, Department of Medicine, Melbourne (Australia); Ditchfield, Michael [Southern Health, Diagnostic Imaging, Melbourne (Australia); Monash Children' s Hospital, Diagnostic Imaging, Melbourne (Australia); Monash University, Department of Medicine, Melbourne (Australia)

    2013-07-15

    Urological investigation in children frequently involves high radiation doses; however, the issue of radiation for these investigations receives little attention compared with CT. To compare the radiation dose from paediatric urological investigations with CT, which is commonly regarded as the more major source of radiation exposure. We conducted a retrospective audit in a tertiary paediatric centre of the number and radiation dose of CT scans, micturating cystourethrography exams and urological nuclear medicine scans from 2006 to 2011. This was compared with radiation doses in the literature and an audit of the frequency of these studies in Australia. The tertiary centre audit demonstrated that the ratio of the frequency of urological to CT examinations was 0.8:1 in children younger than 17 years. The ratio of the radiation dose of urological to CT examinations was 0.7:1. The ratio in children younger than 5 years was 1.9:1. In Australia the frequency of urological procedures compared with CT was 0.4:1 in children younger than 17 years and 3.1:1 in those younger than 5 years. The ratio of radiation-related publications was 1:9 favouring CT. The incidence and radiation dose of paediatric urological studies is comparable to those of CT. Nevertheless the radiation dose of urological procedures receives considerably less attention in the literature. (orig.)

  10. Inter-laboratory comparison of medical computed tomography (CT) scanners for industrial applications in the slaughterhouses

    DEFF Research Database (Denmark)

    Christensen, Lars Bager; Angel, Jais Andreas Breusch

    2013-01-01

    differences in CT performance. The presented Round Robin scheme has demonstrated its potential as such a method. The benefit of the phantom set is that it provides a convenient way of comparing volume determination between different CT scanners. The suggested phantoms are mimicking important carcass features...

  11. Measurement of skeletal muscle area: Comparison of CT and MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sinelnikov, Andrey, E-mail: sinelnikovas@upmc.edu [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Qu, Chuanxing [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Fetzer, David T. [Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Pelletier, Jean-Sébastien [Department of Surgery, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Dunn, Michael A. [Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Tsung, Allan [Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Furlan, Alessandro [Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, PA (United States)

    2016-10-15

    Objective: To investigate the intra- and inter-observer agreement and correlation between CT and MR measurements of skeletal muscle area (SMA) in the abdomen. Methods: CT and MR images from twelve patients were analyzed by two blinded observers using segmentation software (MITK-3M3, Mint Medical and Slice-O-Matic, Tomovision) to quantify SMA. MR images included T1w “in-phase”, T1w “out-of-phase”, and T2w sequences. Inter- and intra-observer agreement was assessed using the intraclass correlation coefficient (ICC). Pearson correlation coefficient (r) was used to correlate measurements obtained on MR with CT. CT and MR measurements were compared with Bland-Altman plots. Results: Intra- and inter-observer agreement for SMA was high for CT and MR. For MR, the measurements on T2w images showed the highest inter-observer agreement (ICC = 0.96). CT SMA correlated closely with MR, with T2w images showing the highest correlation (r = 0.98; P < 0.01). Bland-Altman plots showed a 1.7%–3.9% bias between CT and MR measurements, lowest for T2w images. Conclusions: MR SMA measurements are reproducible and correlate closely with CT. The T2w sequence is recommended to quantify SMA on MR images.

  12. Assessment of CF lung disease using motion corrected PROPELLER MRI: a comparison with CT

    International Nuclear Information System (INIS)

    Ciet, Pierluigi; Serra, Goffredo; Catalano, Carlo; Bertolo, Silvia; Morana, Giovanni; Spronk, Sandra; Ros, Mirco; Fraioli, Francesco; Quattrucci, Serena; Assael, M.B.; Pomerri, Fabio; Tiddens, Harm A.W.M.

    2016-01-01

    To date, PROPELLER MRI, a breathing-motion-insensitive technique, has not been assessed for cystic fibrosis (CF) lung disease. We compared this technique to CT for assessing CF lung disease in children and adults. Thirty-eight stable CF patients (median 21 years, range 6-51 years, 22 female) underwent MRI and CT on the same day. Study protocol included respiratory-triggered PROPELLER MRI and volumetric CT end-inspiratory and -expiratory acquisitions. Two observers scored the images using the CF-MRI and CF-CT systems. Scores were compared with intra-class correlation coefficient (ICC) and Bland-Altman plots. The sensitivity and specificity of MRI versus CT were calculated. MRI sensitivity for detecting severe CF bronchiectasis was 0.33 (CI 0.09-0.57), while specificity was 100 % (CI 0.88-1). ICCs for bronchiectasis and trapped air were as follows: MRI-bronchiectasis (0.79); CT-bronchiectasis (0.85); MRI-trapped air (0.51); CT-trapped air (0.87). Bland-Altman plots showed an MRI tendency to overestimate the severity of bronchiectasis in mild CF disease and underestimate bronchiectasis in severe disease. Motion correction in PROPELLER MRI does not improve assessment of CF lung disease compared to CT. However, the good inter- and intra-observer agreement and the high specificity suggest that MRI might play a role in the short-term follow-up of CF lung disease (i.e. pulmonary exacerbations). (orig.)

  13. Comparison of Three English-to-Dutch Machine Translations of SNOMED CT Procedures

    NARCIS (Netherlands)

    Cornet, Ronald; Hill, Carly; de Keizer, Nicolette

    2017-01-01

    Dutch interface terminologies are needed to use SNOMED CT in the Netherlands. Machine translation may support in their creation. The aim of our study is to compare different machine translations of procedures in SNOMED CT. Procedures were translated using Google Translate, Matecat, and Thot. Google

  14. Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT

    International Nuclear Information System (INIS)

    Wang Yining; Zhang Zhuhua; Kong Lingyan; Song Lan; Merges, Reto D.; Chen Jiuhong; Jin Zhengyu

    2008-01-01

    Objective: To evaluate the performance of dual-source computed tomography (DSCT) for the visualization of the coronary arteries in a population with atrial fibrillation (AF) compared to single-source CT (SSCT) and to explore the impact of patients' heart rate (HR) on image quality (IQ) and reconstruction timing. Methods: Thirty consecutive patients (11 male, 19 female; 69.0 ± 9.2 years old) with suspected coronary artery disease and permanent AF were examined on a DSCT scanner (120 kV, 400 mAs/rot, 0.33 s rotation time, 64 x 0.6 mm collimation, pitch 0.20-0.28, Siemens Somatom Definition). Patients were divided into two groups: low and medium HR group (HR ≤ 80 bpm, n = 14) and high HR group (HR > 80 bpm, n = 16). Five of the patients also underwent conventional coronary angiography (CAG). The raw data from both tube detector arrays were reconstructed as DSCT data using a routine algorithm (temporal resolution of 83 ms). The raw data from one tube detector array was reconstructed separately on the same system using a routine single source algorithm (temporal resolution of 83-165 ms) and defined as virtual SSCT data. Image quality was assessed using a four-point grading scale from excellent (1) to non-assessable (4). Results: IQ of the DSCT data was significantly better than that of the virtual SSCT data (mean score 1.33 ± 0.61 vs. 1.80 ± 1.02; Z = -8.755, P = 0.000). 98.6% of the segments shown in DSCT were diagnostic, compared with 89.9% of the segments in virtual SSCT, χ 2 = 32.595, P = 0.000. In DSCT group, IQ of low HR group was also better than that of high HR group, although the difference was not as big (mean score 1.25 ± 0.52 vs. 1.38 ± 0.66; Z = -2.227, P = 0.026). The mean HR of low HR group and high HR group were 67.4 ± 8.5 beats per minute (bpm) and 94.2 ± 8.8 bpm (t = -8.499, P = 0.000). The range of the variation of HR was higher in high HR group than in low HR group (mean difference between maximum and minimum HR 79.5 ± 21.0 vs. 49.9 ± 21

  15. Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yining [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@hotmail.com; Zhang Zhuhua [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@sina.com; Kong Lingyan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: klyan78@hotmail.com; Song Lan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: sallysonglan@sina.com; Merges, Reto D. [CT Research Collaboration, Siemens Ltd. (China)], E-mail: reto.merges@siemens.com; Chen Jiuhong [CT Research Collaboration, Siemens Ltd. (China)], E-mail: jiuhong.chen@siemens.com; Jin Zhengyu [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: jin_zhengyu@sina.com

    2008-12-15

    Objective: To evaluate the performance of dual-source computed tomography (DSCT) for the visualization of the coronary arteries in a population with atrial fibrillation (AF) compared to single-source CT (SSCT) and to explore the impact of patients' heart rate (HR) on image quality (IQ) and reconstruction timing. Methods: Thirty consecutive patients (11 male, 19 female; 69.0 {+-} 9.2 years old) with suspected coronary artery disease and permanent AF were examined on a DSCT scanner (120 kV, 400 mAs/rot, 0.33 s rotation time, 64 x 0.6 mm collimation, pitch 0.20-0.28, Siemens Somatom Definition). Patients were divided into two groups: low and medium HR group (HR {<=} 80 bpm, n = 14) and high HR group (HR > 80 bpm, n = 16). Five of the patients also underwent conventional coronary angiography (CAG). The raw data from both tube detector arrays were reconstructed as DSCT data using a routine algorithm (temporal resolution of 83 ms). The raw data from one tube detector array was reconstructed separately on the same system using a routine single source algorithm (temporal resolution of 83-165 ms) and defined as virtual SSCT data. Image quality was assessed using a four-point grading scale from excellent (1) to non-assessable (4). Results: IQ of the DSCT data was significantly better than that of the virtual SSCT data (mean score 1.33 {+-} 0.61 vs. 1.80 {+-} 1.02; Z = -8.755, P = 0.000). 98.6% of the segments shown in DSCT were diagnostic, compared with 89.9% of the segments in virtual SSCT, {chi}{sup 2} = 32.595, P = 0.000. In DSCT group, IQ of low HR group was also better than that of high HR group, although the difference was not as big (mean score 1.25 {+-} 0.52 vs. 1.38 {+-} 0.66; Z = -2.227, P = 0.026). The mean HR of low HR group and high HR group were 67.4 {+-} 8.5 beats per minute (bpm) and 94.2 {+-} 8.8 bpm (t = -8.499, P = 0.000). The range of the variation of HR was higher in high HR group than in low HR group (mean difference between maximum and minimum HR

  16. Comparison of CT findings with upper GI series and surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Jin Kyo; Suh, Soo Jhi; Kim, Soon Yong [School of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1981-09-15

    The authors made comparative studies of CT findings with upper GI series and surgical findings in 20 cases of histologically proven gastric cancers. The identification of chickening of gastric wall and local and remote metastasis by CT was thought to be great value in treatment planning and prediction of prognosis of the patients. The results were as follows: 1. Of 20 cases, 19 cases demonstrated thickening of gastric wall. Among 3 cases suggested as early cancer on upper GI series, 2 cases demonstrated thickened gastric wall on CT and it was proved to be advanced cancer at surgery. 2. Out of 8 cases showed no definite metastasis on CT, 4 cases had malignant infiltration histologically in the regional lymph nodes. But they were less than 1.5 cm in diameter. 3. The frequency order of remote metastasis found by CT was pancreas, liver, left adrenal gland and lung in organs and retroperitoneal, retrocrural and regional nodes in lymph nodes.

  17. Comparison of human and automatic segmentations of kidneys from CT images

    International Nuclear Information System (INIS)

    Rao, Manjori; Stough, Joshua; Chi, Y.-Y.; Muller, Keith; Tracton, Gregg; Pizer, Stephen M.; Chaney, Edward L.

    2005-01-01

    Purpose: A controlled observer study was conducted to compare a method for automatic image segmentation with conventional user-guided segmentation of right and left kidneys from planning computerized tomographic (CT) images. Methods and materials: Deformable shape models called m-reps were used to automatically segment right and left kidneys from 12 target CT images, and the results were compared with careful manual segmentations performed by two human experts. M-rep models were trained based on manual segmentations from a collection of images that did not include the targets. Segmentation using m-reps began with interactive initialization to position the kidney model over the target kidney in the image data. Fully automatic segmentation proceeded through two stages at successively smaller spatial scales. At the first stage, a global similarity transformation of the kidney model was computed to position the model closer to the target kidney. The similarity transformation was followed by large-scale deformations based on principal geodesic analysis (PGA). During the second stage, the medial atoms comprising the m-rep model were deformed one by one. This procedure was iterated until no changes were observed. The transformations and deformations at both stages were driven by optimizing an objective function with two terms. One term penalized the currently deformed m-rep by an amount proportional to its deviation from the mean m-rep derived from PGA of the training segmentations. The second term computed a model-to-image match term based on the goodness of match of the trained intensity template for the currently deformed m-rep with the corresponding intensity data in the target image. Human and m-rep segmentations were compared using quantitative metrics provided in a toolset called Valmet. Metrics reported in this article include (1) percent volume overlap; (2) mean surface distance between two segmentations; and (3) maximum surface separation (Hausdorff distance

  18. Diagnostic performance of radiographers as compared to radiologists in magnetic resonance colonography

    International Nuclear Information System (INIS)

    Zijta, F.M.; Florie, J.; Jensch, S.; Bipat, S.; Nievelstein, R.A.J.; Poulus, M.; Thomassen-de Graaf, M.A.; Montauban van Swijndregt, A.D.; Stoker, J.

    2010-01-01

    Purpose: To evaluate the diagnostic performance of radiographers compared to radiologists in the detection of colorectal lesions in MR colonography. Material and methods: 159 patients at increased risk of colorectal cancer were included. Four different experienced observers, one MR radiologist, one radiologist in training and two radiographers evaluated all MR colonography examinations. The protocol included T1-weighted and T2-weighted sequences in prone and supine position. Colonoscopy was used as reference standard. Mean sensitivity rates with 95% confidence intervals (CIs) were determined on a per-patient and per-polyp basis, segmented by size (≥6 mm and ≥10 mm). Specificity was calculated on a per-patient basis. The McNemar and chi-square (χ 2 ) test was used to determine significant differences. Results: At colonoscopy 74 patients (47%) had normal findings; 23 patients had 40 polyps with a size ≥6 mm. In 10 patients at least 1 polyp ≥10 mm was found (20 polyps in total). Similar sensitivities for patients with lesions ≥10 mm were found for radiologists and radiographers (65% (95%CI: 44-86%) vs. 50% (95%CI: 28-72%)) (p = n.s.). For lesions ≥10 mm combined per-patient specificity for radiologists and radiographers was 96% (95%CI: 94-98%) and 73% (95%CI: 68-79%) (p < 0.0001). Combined per-patient sensitivity for lesions ≥6 mm differed significantly between both groups of observers (57% (95%CI: 42-71%) vs. 33% (95%CI: 19-46%)) (p = 0.03). Conclusion: Radiographers have comparable sensitivity but lower specificity relative to radiologists in the detection of colorectal lesions ≥10 mm at MR colonography. Adequate training in evaluating MR colonography is necessary, especially for readers with no prior experience with colonography.

  19. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    International Nuclear Information System (INIS)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F.

    1998-01-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.)

  20. Evaluation of patellar cartilage surface lesions: comparison of CT arthrography and fat-suppressed FLASH 3D MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Daenen, B.R.; Ferrara, M.A.; Marcelis, S.; Dondelinger, R.F. [Department of Medical Imaging, University Hospital Sart-Tilman, Liege (Belgium)

    1998-07-01

    The aim of this study was to evaluate the sensitivity and specificity of fat-suppressed fast low-angle shot (FLASH) 3D MR imaging in the detection of patellar cartilage surface lesions in comparison with CT arthrography. Fifty patients, with or without symptoms of chondromalacia, were prospectively examined by CT arthrography and fat-suppressed 3D gradient-echo MR imaging. All MR examinations were evaluated by three observers, two of them reaching a consensus interpretation. The lesions were graded according to their morphology and their extent. The CT arthrography was considered as the reference examination. For both sets of observers, the final diagnosis of chondromalacia was obtained in 92.5 %. The specificity was 60 % on a patient-by-patient basis. Fissures were missed in 83 and 60 %, respectively, but were isolated findings only in 2.5 % of the cases. Considering ulcers involving more than 50 % of the cartilage thickness, 65 and 88 %, respectively, were recognized. Fat-suppressed FLASH 3D is an adequate pulse sequence for the detection of patellar cartilage ulcers. It can be applied on a routine clinical basis, but it does not show as many fissures as CT arthrography and is less precise for grading of lesions. (orig.) With 4 figs., 3 tabs., 21 refs.

  1. Shallow and deep breath lung tumor volume as estimated by spiral volumetric CT in comparison to standard axial CT using virtual simulation

    International Nuclear Information System (INIS)

    Quader, M.A.; Kalend, A.M.; Deutsch, M.; Greenberger, J.S.

    1995-01-01

    Purpose/Objective: In order to assess an individual patient tumor volume (TV) margins that are sufficient to design a beam-eye-view (BEW) conformal portal, the radiographic extent of gross tumor volume (GTV) dimensions and its fluctuation with breathing are measured by fast spiral CT scanning of patients treated for Stage II, III lung cancers using 5-6 field multi-collimated conformal beams. Materials and Methods: Over the course of conformal radiotherapy for lung cancer, a full thorax CT scans of the patient were taken by conventional axial CT scanning with patients immobilized in the treatment position and breathing normally. Patient(s) with good pulmonary function test (PFT) status were selected to perform deep breathing and re-scanned by fast spiral techniques in order to re-acquire the tomographic variation in the (GTV) with breathing. A Picker spiral ZAP-100 software running on the AQSim-PQ-2000 was used with a variable helical pitch of 1.0, 1.5 and 2.0. The variable pitch spirals were limited to tumor bed, diaphragm and lung apex area for measurements. Effect of breathing motion along x,y,z direction were then assessed for each beam-eye-view portal as seen in digitally reconstructed radiography (DRR) at the treated gantry angle. Results: Comparison of axial and spiral scans shows the progression of lung and diaphram motion with breathing can be gauged better in spiral scans. The movement of the diaphragm during shallow breathing has been found to be 2-3cm by measuring the distance between the most inferior and superior slices where diaphragm is present. The variation of the tumor dimensions along AP/PA and lateral direction seems to be less sensitive to breathing than those along inferior-superior direction. Conclusion: The fast spiral CT scanning is sensitive to patient lung motion and can be used to determine the fluctuations of the gross tumor volume with breathing. The extent of the fluctuation is location dependent and increases as one moves from the

  2. PET/MRI and PET/CT in advanced gynaecological tumours: initial experience and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Marcelo A.; Schulthess, Gustav von; Veit-Haibach, Patrick [University Hospital Zurich, Department Medical Radiology, Nuclear Medicine, Zurich (Switzerland); University Hospital Zurich, Department Medical Radiology, Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Kubik-Huch, Rahel A.; Freiwald-Chilla, Bianka [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Hauser, Nik [Kantonsspital Baden AG, Department of Gynaecology, Baden (Switzerland); Froehlich, Johannes M. [Guerbet AG, Zurich (Switzerland)

    2015-08-15

    To compare the diagnostic accuracy of PET/MRI and PET/CT for staging and re-staging advanced gynaecological cancer patients as well as identify the potential benefits of each method in such a population. Twenty-six patients with suspicious or proven advanced gynaecological cancer (12 ovarian, seven cervical, one vulvar and four endometrial tumours, one uterine metastasis, and one primary peritoneal cancer) underwent whole-body imaging with a sequential trimodality PET/CT/MR system. Images were analysed regarding primary tumour detection and delineation, loco-regional lymph node staging, and abdominal/extra-abdominal distant metastasis detection (last only by PET/CT). Eighteen (69.2 %) patients underwent PET/MRI for primary staging and eight patients (30.8 %) for re-staging their gynaecological malignancies. For primary tumour delineation, PET/MRI accuracy was statistically superior to PET/CT (p < 0.001). Among the different types of cancer, PET/MRI presented better tumour delineation mainly for cervical (6/7) and endometrial (2/3) cancers. PET/MRI for local evaluation as well as PET/CT for extra-abdominal metastases had therapeutic consequences in three and one patients, respectively. PET/CT detected 12 extra-abdominal distant metastases in 26 patients. PET/MRI is superior to PET/CT for primary tumour delineation. No differences were found in detection of regional lymph node involvement and abdominal metastases detection. (orig.)

  3. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    Science.gov (United States)

    Osman, N. D.; Shamsuri, S. B. M.; Tan, Y. W.; Razali, M. A. S. M.; Isa, S. M.

    2017-05-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDIvol and CTDIw) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDIw ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients.

  4. A clinical comparison between Technegas SPECT, CT, and pulmonary function tests in patients with emphysema

    International Nuclear Information System (INIS)

    Satoh, Katashi; Nakano, Satoru; Tanabe, Masatada

    1997-01-01

    Pulmonary emphysema can be easily diagnosed by X-ray CT (CT) as low attenuation areas. Recently 99m Tc Technegas has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of SPECT images using Technegas scintigraphy and CT, as compared with pulmonary function tests in patients with pulmonary emphysema. Fifteen patients were examined. We classified and defined the score according to the findings of Technegas scintigraphy (Technegas) images into four grades, from Score 0 to Score 3, and those of CT into five grades, from Score 0 to Score 4, both from normal to severe. The right lung was divided into nine segments, and the left into eight. To obtain the average of the entire lung, the total score from both lungs was divided by 17. These average scores in for SPECT and CT were compared with the results of pulmonary function tests. The average score of Technegas correlated well with % forced expiratory volume in one second (%FEV 1.0 ) (r=0.87), and forced expiratory volume in one second % (FEV 1.0 %) (r=0.83). These results were better than those provided by CT. The average scores of the upper and lower lung fields were also calculated. The score in the upper lung field was higher than that in the lower field. Technegas can assess ventilation impairment in pulmonary emphysema more easily than CT, especially in the upper lung field. (author)

  5. Comparison of AMI-25 enhanced MRI and helical dynamic CT in the detection of hepatic lesions

    International Nuclear Information System (INIS)

    Saitou, Kazuhiro; Matsuda, Hiromichi; Fukushima, Hiroaki; Kanzaki, Hiroshi; Hirose, Takashi; Karizaki, Dai; Abe, Kimihiko; Amino, Saburou

    1994-01-01

    We performed AMI-25 enhanced MRI and helical dynamic CT in 12 cases of hepatic lesions. Nine of these were hepatocellular carcinomas. Two cases were metastatic liver tumors (the primary lesion was gastric in one and the other was gallbladder cancer). One case was suspected to be adenomatous hyperplasia. Thirty-two lesions were detected in T2-weighted SE images before AMI-25 administration, while 46 lesions were detected in AMI-25 enhanced MRI images. In particular, AMI-25 enhanced MRI was superior to plain MRI in lesions less than 10 mm in size. A total of 48 lesions were detected in helical dynamic CT. Although AMI-25 enhanced MRI almost equaled helical dynamic CT in the detection of liver tumors, helical dynamic CT was slightly superior to AMI-25 enhanced MRI in the detection of subphrenic lesions. It was possible to know the hemodynamics in each hepatic lesion by helical dynamic CT. AMI-25 enhanced MRI was useful to know the inclusion of reticuloendothelial system, and that yielded different diagnoses in adenomatous hyperplasia and well differentiated hepatocellular carcinoma. Helical dynamic CT was useful for qualitative diagnosis. Both AMI-25 enhanced MRI and helical dynamic CT contributed to the detection of liver tumor and qualitative diagnosis. (author)

  6. Comparison of CT and diffusion-weighted MRI in acute ischemic stroke

    International Nuclear Information System (INIS)

    Moriwaki, Hiroshi; Okazaki, Shuhei; Yamada, Naoaki; Naritomi, Hiroaki

    2006-01-01

    Non-contrast CT and diffusion-weighted MRI (DWI) are widely used for assessing patients with acute ischemic stroke including candidates for thrombolytic therapy. Early CT signs, still a gold standard as the diagnostic measure for thrombolysis, are quite subtle and strongly depend on image quality. We evaluated 76 patients (47 male, mean age 71.0 yrs) with ischemic stroke of the anterior cerebral circulation who underwent CT and DWI within 6 hours of onset. The scans were examined separately by two neurologists in a blinded fashion with knowledge of the affected hemisphere. Detection of acute ischemic changes were significantly higher on DWI (72/76, 95%) compared with that on CT (50/76, 66%) (P<0.0001), especially in cases with subcortical lesions (P<0.001). Detection of the lesion with more than 33% of MCA involvement, which should exclude from the thrombolitic therapy, was somewhat higher for DWI (26/26, 100%) compared with CT (22/26, 85%). DWI is more sensitive than CT in the identification of acute ischemic stroke and can visualize major ischemia more easily than CT. Additional studies are required to determine whether these advantages of DWI are clinically relevant in the management of patients with acute stroke. (author)

  7. A single institution study of radiation dose received from CT imaging: A comparison to Malaysian NDRL

    International Nuclear Information System (INIS)

    Osman, N D; Shamsuri, S B M; Razali, M A S M; Isa, S M; Tan, Y W

    2017-01-01

    Advancement of CT technology has led to an increase in CT scanning as it improves the diagnosis. However, it is important to assess health risk of patients associated with ionising radiation received from CT. This study evaluated current dose distributions at Advanced Medical and Dental Institute (AMDI), Malaysia and was used to establish Local Diagnostic Reference Level (LDRL). Dose indicators such as CT Dose Index (CTDI vol and CTDI w ) and Dose-Length Product (DLP) were gathered for all routine CT examinations performed at the Imaging Unit, AMDI from January 2015 to June 2016. The first and third quartile values for each dose indicator were determined. A total of 364 CT studies were performed during that period with the highest number of cases being Thorax-Abdomen-Pelvis (TAP) study (57% of total study). The CTDI w ranged between 2.0 mGy to 23.4 mGy per procedure. DLP values were ranged between 94 mGy.cm to 1687 mGy.cm. The local dose data was compared with the national DRL to monitor the current CT practice at AMDI and LDRL will be established from the calculated third quartile values of dose distribution. From the results, some of the local dose values exceeded the Malaysian and further evaluation is important to ensure the dose optimisation for patients. (paper)

  8. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  9. Visualization of the thymus in myasthenia gravis. Comparison between pneumomediastinography and CT of the anterior mediastinum

    Energy Technology Data Exchange (ETDEWEB)

    Komatsu, Midori; Tanaka, Makoto; Morimatsu, Mitsunori; Hirai, Shunsaku; Heshiki, Atsuko (Gunma Univ., Maebashi (Japan). School of Medicine)

    1982-12-01

    We investigated whether CT had any advantage over pneumomediastinography (PMG) for the visualization of thymus in twenty-one patients with myasthenia gravis (MG). In two cases of thymoma which had been suspected with chest radiography, CT demonstrated an anterior mediastinal tumor distinguishable from other mediastinal organs, and for these cases PMG was not performed. Excluding three patients who were submitted to PMG only, CT of the anterior mediastinum was carried out in sixteen patients of MG, revealing thymic shadows in seven (44%). PMG followed by conventional tomography was done subsequently in three of these seven cases, for whom thymectomy was indicated because of uncontrollable myasthenic symptoms, and in all patients finger-like thymic shadows were disclosed. The vertical extension of thymus was more easily demonstrable by PMG than CT. PMG was carried out in six of nine patients in whom CT was negative, and in all cases thymic shadows were obvious with subsequent conventional tomography. Consequently, false negative rate of CT was at least 38% (6/16) with regard to the visualization of the nontumorous thymus. Although CT of the anterior mediastinum is useful as a screening method because of its non-invasiveness, its negative result does not rule out an absence of the pathologic thymus in view of its high false negative rate. In this regard, PMG is still necessary for the final determination of the thymic configuration in the MG patients.

  10. Detecting subarachnoid hemorrhage: Comparison of combined FLAIR/SWI versus CT

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Rajeev Kumar, E-mail: rajeev.verma@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kottke, Raimund, E-mail: raimund.kottke@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Andereggen, Lukas, E-mail: lukas.andereggen@insel.ch [Department of Neurosurgery, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Weisstanner, Christian, E-mail: christian.weisstanner@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Zubler, Christoph, E-mail: christoph.zubler@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Gralla, Jan, E-mail: jan.gralla@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Kiefer, Claus, E-mail: claus.kiefer@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); Slotboom, Johannes, E-mail: johannes.slotboom@insel.ch [University Institute of Diagnostic and Interventional Neuroradiology, Support Center for Advanced Neuroimaging, University of Bern, Inselspital, Freiburgstrasse 4, 3010 Bern (Switzerland); and others

    2013-09-15

    Objectives: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. Methods: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n = 9), ruptured aneurysm (n = 6), ruptured arteriovenous malformation (n = 2), and spontaneous bleeding (n = 8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. Results: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. Conclusions: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.

  11. Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

    International Nuclear Information System (INIS)

    Souvatzoglou, M.; Ziegler, S.I.; Martinez, M.J.; Dzewas, G.; Schwaiger, M.; Bengel, F.; Busch, R.

    2007-01-01

    In PET/CT, CT-derived attenuation factors may influence standardised uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET. Therefore, we compared PET/CT-derived SUVs intra-individually in various organs and tumour lesions with stand-alone PET-derived SUVs. Thirty-five patients with known or suspected cancer were prospectively included. Sixteen patients underwent FDG PET using an ECAT HR+scanner, and subsequently a second scan using a Biograph Sensation 16PET/CT scanner. Nineteen patients were scanned in the reverse order. All images were reconstructed with an iterative algorithm (OSEM). Suspected lesions were grouped as paradiaphragmatic versus distant from the diaphragm. Mean and maximum SUVs were also calculated for brain, lung, liver, spleen and vertebral bone. The attenuation coefficients (μ values) used for correction of emission data (bone, soft tissue, lung) in the two data sets were determined. A body phantom containing six hot spheres and one cold cylinder was measured using the same protocol as in patients. Forty-six lesions were identified. There was a significant correlation of maximum and mean SUVs derived from PET and PET/CT for 14 paradiaphragmatic lesions (r=0.97 respectively; p<0.001 respectively) and for 32 lesions located distant from the diaphragm (r=0.87 and r=0.89 respectively; p<0.001 respectively). No significant differences were observed in the SUVs calculated with PET and PET/CT in the lesions or in the organs. In the phantom, radioactivity concentration in spheres calculated from PET and from PET/CT correlated significantly (r=0.99; p<0.001). SUVs of cancer lesions and normal organs were comparable between PET and PET/CT, supporting the usefulness of PET/CT-derived SUVs for quantification of tumour metabolism. (orig.)

  12. Comparison of SPECT and CT in detecting skull base invasion in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Zhang Li; Wang Jinchuan; Pu Nuo; Song Wenzhong; Chen Mingxi

    2002-01-01

    Objective: To investigate the detecting ability of single photon emission computed tomography (SPECT) and CT in skull base invasion in nasopharyngeal carcinoma. Methods: Sixty-three patients with nasopharyngeal carcinoma were examined by whole body and skull base SPECT and CT of nasopharynx and skull base before radiotherapy. The results were double-blind compared and evaluated. Results: The overall positive rates of skull base invasion detected by SPECT and CT were 63.5% and 25.4%. In patients with headache, cranial nerve palsy and both, they were 87.9%, 93.3%, 92.3% and 42.4%, 46.7%, 46.2%. In patients with T 1 + T 2 and T 3 + T 4 lesions, they were 37.5%, 90.3% and 0.0%, 51.6%. In patients with N 0 + N 1 and N 2 + N 3 lesions, they were 63.9%, 63.0% and 19.4%, 33.3%. The positive rates of SPECT were higher than those of CT (McNemar Test, P < 0.05). The conformation rate between SPECT and CT was 61.9% and the dissimilitude rate was 38.1%. Binary Logistic regression analysis showed that headache and T stages were risk factors of positive SPECT rate (ORheadache = 3.864, ORTstage= 6.422) while Tstage and Nstage were the risk factors for positive CT rate (ORTstage = 48.932, ORNstage = 2.860). Conclusions: The detection sensitivity of SPECT in skull base invasion in nasopharyngeal carcinoma is superior to that of CT. But its specificity is inferior to that of CT. The detecting results in SPECT are better related to symptoms, signs and stage. Combining headache and cranial nerve palsy with T and N stage, the authors may much improve the results of SPECT and CT in the detection of skull base invasion in nasopharyngeal carcinoma. Further study is warranted

  13. Hyaline cartilage thickness in radiographically normal cadaveric hips: comparison of spiral CT arthrographic and macroscopic measurements.

    Science.gov (United States)

    Wyler, Annabelle; Bousson, Valérie; Bergot, Catherine; Polivka, Marc; Leveque, Eric; Vicaut, Eric; Laredo, Jean-Denis

    2007-02-01

    To assess spiral multidetector computed tomographic (CT) arthrography for the depiction of cartilage thickness in hips without cartilage loss, with evaluation of anatomic slices as the reference standard. Permission to perform imaging studies in cadaveric specimens of individuals who had willed their bodies to science was obtained from the institutional review board. Two independent observers measured the femoral and acetabular hyaline cartilage thickness of 12 radiographically normal cadaveric hips (from six women and five men; age range at death, 52-98 years; mean, 76.5 years) on spiral multidetector CT arthrographic reformations and on coronal anatomic slices. Regions of cartilage loss at gross or histologic examination were excluded. CT arthrographic and anatomic measurements in the coronal plane were compared by using Bland-Altman representation and a paired t test. Differences between mean cartilage thicknesses at the points of measurement were tested by means of analysis of variance. Interobserver and intraobserver reproducibilities were determined. At CT arthrography, mean cartilage thickness ranged from 0.32 to 2.53 mm on the femoral head and from 0.95 to 3.13 mm on the acetabulum. Observers underestimated cartilage thickness in the coronal plane by 0.30 mm +/- 0.52 (mean +/- standard error) at CT arthrography (P cartilage thicknesses at the different measurement points was significant for coronal spiral multidetector CT arthrography and anatomic measurement of the femoral head and acetabulum and for sagittal and transverse CT arthrography of the femoral head (P cartilage thickness from the periphery to the center of the joint ("gradients") were found by means of spiral multidetector CT arthrography and anatomic measurement. Spiral multidetector CT arthrography depicts cartilage thickness gradients in radiographically normal cadaveric hips. (c) RSNA, 2007.

  14. Diagnosing and staging of cystic echinococcosis: how do CT and MRI perform in comparison to ultrasound?

    Directory of Open Access Journals (Sweden)

    Marija Stojkovic

    Full Text Available BACKGROUND: Imaging plays the key role in diagnosing and staging of CE. The description of CE-specific imaging features and the WHO CE cyst classification is based on ultrasound. The reproducibility of the ultrasound-defined features of CE cysts is variable in MR- and CT-imaging. This is of particular importance for cysts that are not accessible by US and because of the increasing availability and overuse of CT and MR imaging. METHODOLOGY/PRINCIPAL FINDINGS: Retrospective analysis of patients with abdominal CE cysts of an interdisciplinary CE clinic who had CT and/or MRI scans performed additionally to US imaging. All images were read and interpreted by the same senior radiologist experienced in the diagnosis of CE. US, CT and MR images were staged according to the WHO classification criteria. The agreement beyond chance was quantified by kappa coefficients (κ. 107 patients with 187 CE cysts met the inclusion criteria. All cysts were assessed by US, 138 by CT, and 125 by MRI. The level of agreement beyond chance of the individual CE stages 1-4 was clearly lower for CT, with κ ranging from 0.62 to 0.72, compared to MRI with values of κ between 0.83 and 1.0. For CE5 cysts CT (κ = 0.95 performed better than MRI (κ = 0.65. CONCLUSIONS: Ultrasound remains the corner stone of diagnosis, staging and follow up of CE cysts. MRI reproduces the ultrasound-defined features of CE better than CT. If US cannot be performed due to cyst location or patient-specific reasons MRI with heavily T2-weighted series is preferable to CT.

  15. Comparison of cerebrospinal fluid dynamics studied by computed tomography (CT) and radioisotope (RI) cisternography

    International Nuclear Information System (INIS)

    Tamaki, N.; Kanazawa, Y.; Asada, M.; Kusunoki, T.; Matsumoto, S.

    1978-01-01

    CT and RI cisternography were done on 55 cases with normal and abnormal CSF circulation. Of 19 cases in which both studies were done, 14 cases disclosed a good correspondence. The remaining five cases showed no correspondence because of technical failure. Analyzing the results, CT cisternography demonstrates pathology of the CSF dynamics in a more precise and quantitative manner than RI cisternography does. Metrizamide CT cisternography will soon be the most reliable method of investigation for the evaluation of the CSF kinetics. (orig.) [de

  16. CT findings in ten patients with failed renal allografts: comparison with findings in functional grafts

    International Nuclear Information System (INIS)

    Gayer, Gabriela; Apter, Sara; Katz, Rama; Ben-David, Aharon; Katzir, Ze'ev; Hertz, Marjorie

    2000-01-01

    Our aim is to report the computed tomography (CT) features of the long-term failed renal allograft. Ten patients with failed renal transplants in whom the graft was left in situ underwent CT for various unrelated indications. The majority of the failed grafts showed marked shrinkage and coarse punctate diffuse parenchymal calcifications. Small cysts were seen in four grafts. A long-term failed renal transplant appeared on CT as a small rounded soft tissue mass. The graft was almost always heavily calcified. Lack of awareness of the nature of such a mass may mislead the radiologist in interpreting it as a space-occupying lesion

  17. Comparison of MR imaging and CT in the evaluation of uterine tumors

    International Nuclear Information System (INIS)

    Janus, C.L.; Dottino, P.; Brodman, M.; Goodman, H.; Gendal, E.S.; Rabinowitz, J.G.

    1987-01-01

    The authors compared the usefulness of MR imaging and CT in staging uterine tumors. Forty women with known cervical carcinoma, endometrial cancer, or leiomyosarcoma underwent CT and MR imaging within 1 week prior to surgery. MR imaging was better than CT for localizing tumors to the endometrium of myometrium and in the evaluation of lymph node involvement and extension to the cervix and parametria. MR imaging, with its superior ability to demonstrate pelvic anatomy and its lack of ionizing radiation and risk from iodinated contrast media, has an important place in the staging of uterine tumors

  18. Magnetic resonance imaging of the central nervous system. Comparison with X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Kajima, Toshio; Kagawa, Yoshihiro; Katsuta, Shizutomo.

    1987-06-01

    Magnetic resonance imaging (MRI) and X-ray computed tomography (X-ray CT) have been performed in 169 consecutive patients with central nervous system diseases. The findings from the two methods were compared for the capacity to defect lesions. Magnetic resonance imaging was more sensitive than or equivalent to X-ray CT in detecting lesions - especially detecting. Arnold-Chiari malformation, syringomyelia, spinal cord injury, and pituitary adenoma - in 158 patients (94 %). In six patients (10 %), lesion detection was possible only by MRI. Magnetic resonance imaging was inferior to X-ray CT in 11 patients (7 %) in detecting calcified lesions, meningioma, and cavernous hemangioma. (Namekawa, K.).

  19. Comparison of MR imaging and CT in neuroendrocrine disorders in children

    International Nuclear Information System (INIS)

    Garreh, M.K.; Ball, W.S.; Brody, A.S.; Dolan, L.; Burton, E.M.

    1989-01-01

    MR imaging has been shown to be superior in imaging the adult hypothalamicpituitary axis. The authors have reviewed the CT and MR findings in children with known abnormalities, including hamartoma of the tuber cinereum, craniopharyngiomas,. pituitary adenoma, Rathke cleft cyst, incomplete pituitary stalk, and septo-optic dysplasia. Clinical correlation and typical CT and MR features were analyzed. In four cases, abnormalities were not visualized on CT. The authors conclude that because of its unique sensitivity and excellent anatomic resolution, MR imaging is the modality of choice in the imaging of neuroendocrine disorders in children

  20. Quantification of neonatal lung parenchymal density via ultrashort echo time MRI with comparison to CT.

    Science.gov (United States)

    Higano, Nara S; Fleck, Robert J; Spielberg, David R; Walkup, Laura L; Hahn, Andrew D; Thomen, Robert P; Merhar, Stephanie L; Kingma, Paul S; Tkach, Jean A; Fain, Sean B; Woods, Jason C

    2017-10-01

    To demonstrate that ultrashort echo time (UTE) magnetic resonance imaging (MRI) can achieve computed tomography (CT)-like quantification of lung parenchyma in free-breathing, non-sedated neonates. Because infant CTs are used sparingly, parenchymal disease evaluation via UTE MRI has potential for translational impact. Two neonatal control cohorts without suspected pulmonary morbidities underwent either a research UTE MRI (n = 5; 1.5T) or a clinically-ordered CT (n = 9). Whole-lung means and anterior-posterior gradients of UTE-measured image intensity (arbitrary units, au, normalized to muscle) and CT-measured density (g/cm 3 ) were compared (Mann-Whitney U-test). Separately, a diseased neonatal cohort (n = 5) with various pulmonary morbidities underwent both UTE MRI and CT. UTE intensity and CT density were compared with Spearman correlations within ∼33 anatomically matched regions of interest (ROIs) in each diseased subject, spanning low- to high-density tissues. Radiological classifications were evaluated in all ROIs, with mean UTE intensities and CT densities compared in each classification. In control subjects, whole-lung UTE intensities (0.51 ± 0.04 au) were similar to CT densities (0.44 ± 0.09 g/cm 3 ) (P = 0.062), as were UTE (0.021 ± 0.020 au/cm) and CT (0.034 ± 0.024 [g/cm 3 ]/cm) anterior-posterior gradients (P = 0.351). In diseased subjects' ROIs, significant correlations were observed between UTE and CT (P ≤0.007 in each case). Relative differences between UTE and CT were small in all classifications (4-25%). These results demonstrate a strong association between UTE image intensity and CT density, both between whole-lung tissue in control patients and regional radiological pathologies in diseased patients. This indicates the potential for UTE MRI to longitudinally evaluate neonatal pulmonary disease and to provide visualization of pathologies similar to CT, without sedation/anesthesia or ionizing radiation

  1. Temporal lobe epilepsy: Comparison of CT and MR in 100 patients

    International Nuclear Information System (INIS)

    Schoerner, W.; Meencke, H.J.; Sander, B.; Henkes, H.; Felix, R.; Klinikum Rudolf Virchow, Berlin

    1989-01-01

    The value of CT and MR was studied in 100 patients with temporal lobe epilepsy. Axial CT scans were obtained before and after contrast injection. Coronary MR scans were carried out with T 1 -(SE 400/30, GE 315/14) and T 2 -weighted sequences (SE 1600/30 + 70). A circumscribed lesion was demonstrated in fifteen patients by CT and in 25 patients by MR. With the exception of a small area of calcification, all lesions seen on CT could also be recognized on MR. Better sensitivity and improved demonstration of the temporal lobes makes MR the method of choice in the diagnosis of temporal lobe epilepsy. (orig./GDG) [de

  2. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    International Nuclear Information System (INIS)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W.; DiMartino, E.; Prescher, A.; Kinzel, S.

    2004-01-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  3. Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, G.A.; Schmitz-Rode, T.; Haage, P.; Guenther, R.W. [Department of Diagnostic Radiology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); DiMartino, E. [Department of Otorhinolaryngology, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Prescher, A. [Department of Anatomy, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany); Kinzel, S. [Department of Experimental Veterinary Medicine, University of Technology, Pauwelstrasse 30, 52057, Aachen (Germany)

    2004-04-01

    We assessed the value of MRI for delineation of dehiscence of the superior or posterior semicircular canal, as compared with CT, the current standard study for this entity. We reviewed heavily T2-weighted fast spin-echo images and high-resolution CT of the temporal bones of 185 patients independently semicircular canal dehiscence and its extent. In 30 patients (19 men, 11 women) we identified dehiscence of the bone over the superior and/or posterior semicircular canal on MRI. In 27 of these cases CT also showed circumscribed bone defects. In one patient dehiscence of the superior semicircular canal was initially overlooked on MRI, but seen on CT. MRI imaging thus had a sensitivity of 96% and specificity of 98%. Knowledge of the appearances of this entity on MRI may contribute to early diagnosis in patients with vertigo due to semicircular canal dehiscence. (orig.)

  4. A comparison of micro-CT, microradiography and histomorphometry in bone research

    NARCIS (Netherlands)

    Gielkens, Pepijn F. M.; Schortinghuis, Jurjen; de Jong, Johan R.; Huysmans, Marie Charlotte D. N. J. M.; van Leeuwen, M. Barbara M.; Raghoebar, Gerry M.; Bos, Ruud R. M.; Stegenga, Boudewijn

    Objective: Intraobserver reliability and agreement were determined for microradiography (MR), micro-computed tomography (mu CT) and histomorphometry (HM). These three modalities were compared for quantitative measurements of bone formation and graft modelling in rat mandibular defects and grafts.

  5. Comparison of Ct and MRI in the study of the pituitary gland

    International Nuclear Information System (INIS)

    Juliani, G.; Avataneo, T.; Potenzoni, F.; Sorrentino, T

    1989-01-01

    Normal CT and MR anatomy was studied in two series (53 and 25 cases respectively) of young volunteers of both sexes, asymptomatic and certainly without lesions of the pituitary gland. 115 other pathological cases (73 hyperprolactinemias, 8 acromegalies, 15 Cushing syndromes, 2 hyperthyroidisms, 17 non-secreting adenomas) were examined using both CT and MRI. Both an accurate review of the relative literature and the results of our own series prove that MR is superior to CT in diagnosing pituitary microadenomas (3.2% not diagnosed with MRI and 25.8% not diagnosed with CT), in the follow-up of prolactinomas subjected to medical therapy and in the study of extrasellar involvement of pituitery adenomas, particularly with regard to the demonstration of compression of the optic chiasma

  6. Proton MRI in the evaluation of pulmonary sarcoidosis: Comparison to chest CT

    International Nuclear Information System (INIS)

    Chung, Jonathan H.; Little, Brent P.; Forssen, Anna V.; Yong, Jin; Nambu, Atsushi; Kazlouski, Demitry; Puderbach, Michael; Biederer, Juergen; Lynch, David A.

    2013-01-01

    Purpose: The purpose of this study was to determine the feasibility of proton MRI of the lung in sarcoidosis patients and the agreement between the imaging appearance of pulmonary sarcoidosis on MRI and CT. Materials and methods: Chest CT scans and dedicated pulmonary MRI scans (including HASTE, VIBE, and TrueFISP sequences) were performed within 90 days of each other in 29 patients. The scans were scored for gross parenchymal opacification, reticulation, nodules, and masses using a 3-point lobar scale. Total and subset scores for corresponding MRI and CT scans were compared using the Spearman correlation test, Bland–Altman plots, and Cohen's quadratic-weighted kappa analysis. MRI scores were compared to CT by lobe and disease category, using percentage agreement, Spearman rank correlation, and Cohen's quadratic-weighted kappa. Results: The mean (±s.d.) time between MRI and CT scans was 33 ± 32 days. There was substantial correlation and agreement between total disease scoring on MRI and CT with a Spearman correlation coefficient of 0.774 (p < 0.0001) and a Cohen's weighted kappa score of 0.646. Correlation and agreement were highest for gross parenchymal opacification (0.695, 0.528) and reticulation (0.609, 0.445), and lowest in the setting of nodules (0.501, 0.305). Agreement testing was not performed for mass scores due to low prevalence. Upper lobe scoring on MRI and CT demonstrated greater agreement compared to the lower lobes (average difference in Cohen's weighted kappa score of 0.112). Conclusion: There is substantial correlation and agreement between MRI and CT in the scoring of pulmonary sarcoidosis, though MRI evaluation in the upper lobes may be more accurate than in the lower lobes

  7. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  8. MRI-guided and CT-guided cervical nerve root infiltration therapy. A cost comparison

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, M.H.; Froeling, V.; Roettgen, R.; Bucourt, M. de; Hamm, B.; Streitparth, F. [Charite University Medicine Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Bretschneider, T. [Magdeburg Univ. (Germany). Dept. of Radiology and