  1. Postmortem CT Angiography Compared with Autopsy: A Forensic Multicenter Study.

    Science.gov (United States)

    Grabherr, Silke; Heinemann, Axel; Vogel, Hermann; Rutty, Guy; Morgan, Bruno; Woźniak, Krzysztof; Dedouit, Fabrice; Fischer, Florian; Lochner, Stefanie; Wittig, Holger; Guglielmi, Giuseppe; Eplinius, Franziska; Michaud, Katarzyna; Palmiere, Cristian; Chevallier, Christine; Mangin, Patrice; Grimm, Jochen M

    2018-05-01

    Purpose To determine if postmortem computed tomography (CT) and postmortem CT angiography help to detect more lesions than autopsy in postmortem examinations, to evaluate the strengths and weaknesses of each method, and to define their indications. Materials and Methods Postmortem CT angiography was performed on 500 human corpses and followed by conventional autopsy. Nine centers were involved. All CT images were read by an experienced team including one forensic pathologist and one radiologist, blinded to the autopsy results. All findings were recorded for each method and categorized by anatomic structure (bone, organ parenchyma, soft tissue, and vascular) and relative importance in the forensic case (essential, useful, and unimportant). Results Among 18 654 findings, autopsies helped to identify 61.3% (11 433 of 18 654), postmortem CT helped to identify 76.0% (14 179 of 18 654), and postmortem CT angiography helped to identify 89.9% (16 780 of 18 654; P < .001). Postmortem CT angiography was superior to autopsy, especially at helping to identify essential skeletal lesions (96.1% [625 of 650] vs 65.4% [425 of 650], respectively; P < .001) and vascular lesions (93.5% [938 of 1003] vs 65.3% [655 of 1003], respectively; P < .001). Among the forensically essential findings, 23.4% (1029 of 4393) were not detected at autopsy, while only 9.7% (428 of 4393) were missed at postmortem CT angiography (P < .001). The best results were obtained when postmortem CT angiography was combined with autopsy. Conclusion Postmortem CT and postmortem CT angiography and autopsy each detect important lesions not detected by the other method. More lesions were identified by combining postmortem CT angiography and autopsy, which may increase the quality of postmortem diagnosis. Online supplemental material is available for this article.

  2. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  3. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  4. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  5. Coronary CT angiography: Diagnostic value and clinical challenges.

    Science.gov (United States)

    Sabarudin, Akmal; Sun, Zhonghua

    2013-12-26

    Coronary computed tomography (CT) angiography has been increasingly used in the diagnosis of coronary artery disease due to improved spatial and temporal resolution with high diagnostic value being reported when compared to invasive coronary angiography. Diagnostic performance of coronary CT angiography has been significantly improved with the technological developments in multislice CT scanners from the early generation of 4-slice CT to the latest 320- slice CT scanners. Despite the promising diagnostic value, coronary CT angiography is still limited in some areas, such as inferior temporal resolution, motion-related artifacts and high false positive results due to severe calcification. The aim of this review is to present an overview of the technical developments of multislice CT and diagnostic value of coronary CT angiography in coronary artery disease based on different generations of multislice CT scanners. Prognostic value of coronary CT angiography in coronary artery disease is also discussed, while limitations and challenges of coronary CT angiography are highlighted.

  6. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  7. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    stenoses and two diagnostic studies using intracoronary pressure measurement as the reference standard (identification of functionally relevant stenoses were included in the medical evaluation. Meta-analysis of the nine studies of higher methodological quality showed that, CT coronary angiography with invasive coronary angiography as the reference standard, had a sensitivity of 96 % (95 % CI: 93 % to 98 %, specificity of 86 % (95 % CI: 83 % to 89 %, positive likelihood ratio of 6.38 (95 % CI: 5.18 to 7.87 and negative likelihood ratio of 0.06 (95 % CI: 0.03 to 0.10. However, due to non-diagnostic CT images approximately 3.6 % of the examined patients required a subsequent invasive coronary angiography. Using intracoronary pressure measurement as the reference standard, CT coronary angiography compared to invasive coronary angiography had a sensitivity of 80 % (95 % CI: 61 % to 92 % versus 67 % (95 % CI: 51 % to 78 %, a specificity of 67 % (95 % CI: 47 % to 83 % versus 75 % (95 % CI: 60 % to 86 %, an average positive likelihood ratio of 2.3 versus 2.6, and an average negative likelihood ratio 0.3 versus 0.4, respectively. Compared to invasive coronary angiography, the average effective radiation dose of CT coronary angiography was higher with retrospective electrocardiogram (ECG gating and relatively similar with prospective ECG gating. The health economic model using invasive coronary angiography as the reference standard showed that at a pretest probability of CHD of 50 % or lower, CT coronary angiography resulted in lower cost per patient with true positive diagnosis. At a pretest probability of CHD of 70 % or higher, invasive coronary angiography was associated with lower cost per patient with true positive diagnosis. Using intracoronary pressure measurement as the reference standard, both types of coronary angiographies resulted in substantially higher cost per patient with true positive diagnosis. Two publications dealing explicitly with ethical aspects were

  8. Detection of aneurysms in subarachnoidal hemorrhage - CT-angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Roehnert, W.; Haenig, V.; Hietschold, V.; Abolmaali, N.

    1998-01-01

    Purpose: The value of CT-angiography (CT-A) for the visualization of intracranial aneurysms was more closely defined by comparison with digital subtraction angiography (DSA). Methods: Over a period of 18 months a total of 106 patients in whom a subarachnoidal hemorrhage had been detected on native CT were examined in parallel by spiral CT and DSA. CT-angiography was performed under standardized parameters and included processing with 3D surface reconstructions. Results: In 64 patients (60.4%) at total of 72 aneurysms were detected. In four cases (6.2%) there were two and in two cases (3.1%) even three aneurysms. The findings of DSA and CTA agreed in 98 cases (92.5%). In four patients (3.8%) a false negative results was obtained in CTA and the initial DSA. Conclusions: Digital subtraction angiography must still be considered as the gold standard in the diagnosis of cerebral aneurysms. On account of its excellent spatial delineation of aneurysms and possibilities for exact measurements, CT-angiography represents a valuable, supplementary method - in some cases also an alternative method - to digital subtraction angiography. (orig.) [de

  9. Time-resolved CT angiography in aortic dissection

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Nikolaou, Konstantin; Weidenhagen, Rolf; Hellbach, Katharina; Helck, Andreas; Bamberg, Fabian; Reiser, Maximilian F.; Sommer, Wieland H.

    2012-01-01

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  10. Latest techniques in head and neck CT angiography

    International Nuclear Information System (INIS)

    Schuknecht, B.

    2004-01-01

    Continuous evolution of multi row CT is increasingly making CT angiography a viable imaging modality for assessment of the supraaortic and intracranial vessels as an anatomically and functionally coherent vascular system. Extended non-invasive examinations with reduced contrast volume have become feasible with the availability of 16 and 64 row MDCT scanners. Prerequisites to obtain high resolution CT angiographies of the head and neck vessels with superior detail include the administration of low contrast volume, high contrast density (400 mg I/ml) contrast media, adequate timing and data acquisition, optimal flow rate (4 ml/s) and saline flushing. Non-invasiveness, delineation of vessel calcification, virtual independence from hemodynamic conditions, and the ability to provide quantification without needing to correct for magnification are all attributes that favour CT angiography over digital subtraction angiography and to some extent even magnetic resonance angiography as an alternative non-invasive technique. CT angiography is established as a modality of choice for the assessment of patients with acute stroke and chronic steno-occlusive disease. CT angiography may indicate the presence of extra- or intracranial acute vessel occlusion and dissection, predisposing atherosclerotic steno-occlusive disease and thus indicate thrombo-embolism or local appositional thrombosis as the principle pathogenic factor. CT angiography is used to assess anatomy, and to depict the presence, location and extent of calcified and non-calcified plaque as a cause of high grade stenosis. Despite relatively limited sensitivity CT angiography is indicated for suspected or confirmed aneurysms that demand further verification of their presence, geometry, or relationship to parent artery branches and osseous anatomic landmarks. Low volume high density contrast media have substantially increased the ability of CT angiography to depict small aneurysms, small branches, and collateral vessels

  11. Diagnosis of clinical staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Kobayashi, Isao; Igawa, Mikio; Ohnishi, Yoshio; Nakano, Hiroshi; Nihira, Hiromi; Mori, Masaki; Okada, Mitsuo.

    1984-01-01

    The preoperative staging of bladder cancer is of fundamental importance for prognostic evaluation and surgical indication. We studied the accuracy of computed tomography (CT) and angiography in defining the extent of local invasion in 16 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 75 % and 50 % respectively. In low stage, the accuracy was 90 % in CT and 70 % in angiography. In high stage, the accuracy was 50 % in CT and 16.7 % in angiography. Our results seems to indicate lower accuracy in high stage bladder cancer compared with other research. Data from a much larger series are required to ascertain whether the additional information provided by CT and angiography will produce any improvement in patient management. (author)

  12. Comparative study of multi-slice spiral CT angiography and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity

    International Nuclear Information System (INIS)

    Li Wanjun; Lai Zhenhui; Cui Dong; Lin Xiupeng; Du Muxuan

    2010-01-01

    Objective: To compare the difference between multi-slice spiral CT angiography (MSCTA) and color doppler ultrasound in diagnosis of arteriosclerotic occlusive disease of lower extremity. Methods: Patients with arteriosclerosis occlusion were assessed by color doppler ultrasound, multi-slice spiral CT angiography and digital subtraction angiography (DSA). The image information of color doppler ultrasound and MSCTA were compared with that of DSA. Results: Color doppler ultrasound showed the anatomical shape and hemodynamics of the arteries of lower extremity. The sensitivity, specificity, and accuracy for diagnosis arteriosclerotic occlusive disease of lower extremity were 88.04%, 90.69% and 88.77% respectively. MSCTA showed the three dimensional structure of the arteries of lower extremity as well as the collateral arteries and the distal arterials. The sensitivity, specificity and accuracy of MSCTA were 97.69%, 96.90% and 97.66%, respectively. Conclusion: Multi-slice spiral CT angiography is an ideal imaging method for the diagnosis of arteriosclerotic occlusive disease of lower extremity. (authors)

  13. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  14. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chua, A. E.; Ridley, L. J.

    2008-01-01

    Full text: The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (x 2 = 3.5, P=0.6) and (x 2 - 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  15. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  16. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    International Nuclear Information System (INIS)

    Rajaram, Smitha; Swift, Andrew J.; Wild, Jim M.; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Kiely, David G.; Hurdman, Judith

    2012-01-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  17. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    International Nuclear Information System (INIS)

    Gao Sijia; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui; Zang Peizhuo; Shi Qiang; Wang Qiang; Liang Chuansheng; Xu Ke

    2009-01-01

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with χ 2 -test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show AVM not AVF. The

  18. The clinical application studies of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gao Sijia [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)], E-mail: scarlettgao@126.com; Zhang Mengwei; Liu Xiping; Zh Yushen; Liu Jinghong; Wang Zhonghui [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Zang Peizhuo [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Shi Qiang; Wang Qiang [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Liang Chuansheng [Department of Neurosurgery, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China); Xu Ke [Department of Radiology, No. 1 Affiliated Hospital of China Medical University, Shenyang 110001 (China)

    2009-07-15

    Background and purpose: To explore the value of CT spinal angiography with 64-detector row spiral CT in diagnosing spinal vascular malformations. Methods: Seventeen patients with initial MR and clinical findings suggestive of spinal vascular diseases underwent CT spinal angiography. Among these, 14 patients took DSA examination within 1 week after CT scan, 7 patients underwent surgical treatment, and 6 patients underwent vascular intervention embolotheraphy. CT protocol: TOSHIBA Aquilion 64 Slice CT scanner, 0.5 mm thickness, 0.5 s/r, 120 kV and 350 mA, positioned at the aortic arch level, and applied with 'sure start' technique with CT threshold of 180 Hu. Contrast agent Iohexol (370 mg I/ml) was injected at 6 ml/s velocity with total volume of 80 ml. The post-processing procedures included MPR, CPR, MIP, VR, etc. Among the 17 patients, four patients underwent fast dynamic contrast-enhanced 3D MR angiography imaging. CT spinal angiography and three-dimensional contrast-enhanced MR angiography (3D CE-MRA) images were compared and evaluated with DSA and operation results based on disease type, lesion range, feeding arteries, fistulas, draining veins of vascular malformation by three experienced neuroradiologists independently, using double blind method. The data were analyzed using SPSS analytic software with {chi}{sup 2}-test. We compared the results with DSA and operation results. Results: The statistical analysis of the diagnostic results by the three experienced neuroradiologists had no statistical difference (P > 0.05). All of the 17 patients showed clearly the abnormality of spinal cord vessels and the range of lesions by CT spinal angiography. Among them, one patient was diagnosed as arteriovenous fistulas (AVF) by MRI and CT spinal angiography, which was verified by surgical operation. DSA of the same patient, however, did not visualize the lesion. One case was diagnosed as AVM complicated with AVF by DSA, but CT spinal angiography could only show

  19. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    International Nuclear Information System (INIS)

    Marini, Davide; Agnoletti, Gabriella; Brunelle, Francis; Sidi, Daniel; Bonnet, Damien; Ou, Phalla

    2009-01-01

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 ± 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 ± 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surgery.

  20. CT Angiography in the Diagnosis of Brain Death

    International Nuclear Information System (INIS)

    Sawicki, Marcin; Bohatyrewicz, Romuald; Walecka, Anna; Sołek-Pastuszka, Joanna; Rowiński, Olgierd; Walecki, Jerzy

    2014-01-01

    Summary Brain death is defined as the irreversible cessation of functioning of the entire brain, including the brainstem. Brain death is principally established using clinical criteria including coma, absence of brainstem reflexes and loss of central drive to breathe assessed with apnea test. In situations in which clinical testing cannot be performed or when uncertainty exists about the reliability of its parts due to confounding conditions ancillary tests (i.a. imaging studies) may be useful. The objective of ancillary tests in the diagnosis of brain death is to demonstrate the absence of cerebral electrical activity (EEG and evoked potentials) or cerebral circulatory arrest. In clinical practice catheter cerebral angiography, perfusion scintigraphy, transcranial Doppler sonography, CT angiography and MR angiography are used. Other methods, like perfusion CT, xenon CT, MR spectroscopy, diffusion weighted MRI and functional MRI are being studied as potentially useful in the diagnosis of brain death. CT angiography has recently attracted attention as a promising alternative to catheter angiography – a reference test in the diagnosis of brain death. Since 1998 several major studies were published and national guidelines were introduced in several countries (e.g. in France, Austria, Switzerland, the Netherlands and Canada). This paper reviews technique, characteristic findings and criteria for the diagnosis of cerebral circulatory arrest in CT angiography

  1. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  2. Evaluation of spinal cord vessels using multi-slice CT angiography

    International Nuclear Information System (INIS)

    Chen Shuang; Zhu Ruijiang; Feng Xiaoyuan

    2006-01-01

    Objective: To evaluate the value of Multi-slice spiral CT angiography for spinal cord vessels. Methods: 11 adult subjects with suspected of myelopathy were performed with Multi-slice spiral CT angiography, An iodine contrast agent was injected at 3.5 ml/s, for total 100 ml. The parameters were axial 16 slice mode, 0.625 mm slice thickness, 0.8 s rotation, delay time depending on smartprep(15-25 s), multi-phase scan. The coronal and sagittal MPR and SSD were generated on a workstation compared with spinal digital subtraction angiography (DSA) to analyze normal or abnormal spinal cord vessels. Results: Normal findings at spinal CTA and digital subtraction angiography in six adult normal subjects and spinal cord vascular malformations (1 intradural extramedullary AVF, 4 dural AVFs) in five cases, Recognizable intradural vessels corresponding to anterior median (midline) veins and/or anterior spinal arteries were show in six adult normal subjects. Abnormal intradural vessels were detected in all five spinal cord vascular malformation with CT angiography, in comparison with digital subtraction angiography these vessels were primarily enlarged veins of the coronal venous plexus on the cord surface, radiculomedullary-dural arteries could not be clearly shown in four dural AVF, only one anterior spinal artery was detected in one patient with intradural medullary AVF, which direct shunt between anterior spinal artery and perimedullary vein with tortuous draining vessel. Conclusion: Multi-slice CT angiography is able to visualize the normal or abnormal spinal cord vessels. It could be used as a noninvasive method to screen the spinal cord vascular disease. (authors)

  3. The comparative study between multi-slice spiral CT angiography and color flow ultrasonography in hepatic and splenic trauma

    International Nuclear Information System (INIS)

    Yan Youxia; Zhang Jin'e; Chen Xiaocong; Cai Shufang

    2007-01-01

    Objective: To investigate the clinical value of multi-slice spiral CT angiography and color flow ultra- sonography in hepatic and splenic trauma. Methods Thirty-six cases of hepatic and splenic trauma were collected, the MSCT were analyzed and compared with that of color flow ultrasonography. Results: Seventeen cases were Hepatic trauma including nine cases of hepatic contusion, six cases of sub-envelope hematoma, two cases of both sub-envelope hematoma and hepatic contusion. Nineteen cases were splenic trauma including nine cases of splenic contusion, ten cases of sub-envelope hematoma. Conclusion: Multi-slice spiral CT angiography show hepatic and splenic trauma clearer than that of color flow ultrasonography, and can provide reliable basis for clinic diagnosis and therapy. (authors)

  4. Imaging of acute mesenteric ischemia using multidetector CT and CT angiography in a porcine model.

    Science.gov (United States)

    Rosow, David E; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I; Mueller, Peter R; Fernández-del Castillo, Carlos; Warshaw, Andrew L; Thayer, Sarah P

    2005-12-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly facilitates the use of CT angiography (CTA) in the clinical setting. We sought to determine whether M.D.CT-CTA could accurately demonstrate vascular anatomy and capture the earliest stages of mesenteric ischemia in a porcine model. Pigs underwent embolization of branches of the superior mesenteric artery, then imaging by M.D.CT-CTA with three-dimensional reconstruction protocols. After scanning, diseased bowel segments were surgically resected and pathologically examined. Multidetector row CT and CT angiography reliably defined normal and occluded mesenteric vessels in the pig. It detected early changes of ischemia including poor arterial enhancement and venous dilatation, which were seen in all ischemic animals. The radiographic findings--compared with pathologic diagnoses-- predicted ischemia, with a positive predictive value of 92%. These results indicate that M.D.CT-CTA holds great promise for the early detection necessary for successful treatment of acute mesenteric ischemia.

  5. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Özgen, Ali, E-mail: draliozgen@hotmail.com [Yeditepe University Hospital, Department of Radiology (Turkey); Sanioğlu, Soner [Yeditepe University Hospital, Department of Cardiovascular Surgery (Turkey); Bingöl, Uğur Anıl [Yeditepe University Hospital, Department of Plastic Surgery (Turkey)

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatinine levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.

  6. Prognostic value of combined CT angiography and myocardial perfusion imaging versus invasive coronary angiography and nuclear stress perfusion imaging in the prediction of major adverse cardiovascular events

    DEFF Research Database (Denmark)

    Chen, Marcus Y.; Rochitte, Carlos E.; Arbab-Zadeh, Armin

    2017-01-01

    Purpose: To compare the prognostic importance (time to major adverse cardiovascular event [MACE]) of combined computed tomography (CT) angiography and CT myocardial stress perfusion imaging with that of combined invasive coronary angiography (ICA) and stress single photon emission CT myocardial p...

  7. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  8. Spontaneous rectus sheath hematoma: The utility of CT angiography

    Directory of Open Access Journals (Sweden)

    Antonio Pierro, MD

    2018-04-01

    Full Text Available We described the utility of computed tomography (CT angiography in detection of bleeding vessels for a rapid percutaneous arterial embolization of the spontaneous rectus sheath hematoma. A 70-year-old woman comes to our attention with acute abdominal pain and a low hemoglobin level. An unenhanced CT was performed demonstrating a large rectus sheath hematoma. A conservative management was initially established. Despite this therapy, the abdominal pain increased together with a further decrease of hemoglobin values. A CT angiography was then performed, demonstrating an active bleeding within the hematoma and addressing the patient to a rapid percutaneous arterial embolization. Keywords: Rectus sheath hematoma, Acute abdomen, Arterial embolization, CT angiography, Active bleeding

  9. The Efficacy of Iopamidol (Pamiray 370) in Aortic and Extremity CT Angiography

    International Nuclear Information System (INIS)

    Lee, Yoo Jin; Lee, Jong Min; Lee, Hui Joong; Park, Ji Won

    2010-01-01

    To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray 370) during an aortic and extremity CT angiography. Between August and December of 2008, 100 patients (M:F=51:49; mean age, 59 years) underwent an aortic and extremity CT angiography using Pamiray 370 based with informed consent. All changes in vital signs, clinical symptoms, and adverse reactions to the contrast media were monitored. Two radiologists assessed the image quality of the CT angiography. A statistical comparison was conducted using an independent t-test and a Mann-Whitney test based on the 100-patient group studied using Optiray 350. The contrast enhancement of the descending aorta in the arterial phase showed a statistically greater efficacy (p<0.001) of Pamiray 370 compared to Optiray 350, which was the routine contrast media for CT angiography for our institute. Adverse reaction signs were evident in 3%(3/100) of the subjects. All of them showed mild and transient reactions such as vomiting (n=2) and coughing (n=1), with no medical treatment required. Contrast media related symptoms including dizziness (n=7), nausea (n=3), headaches (n=2), and injection site pain (n=1), were noted in 12%(12/100). The clinical efficacy of Pamiray 370 was acceptable for the aortic and extremity CT angiography, in terms of clinical safety, tolerance, and image quality

  10. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  11. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact

    International Nuclear Information System (INIS)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J.

    2002-01-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs

  12. Spiral CT-angiography of the aorta

    NARCIS (Netherlands)

    Balm, R.; Eikelboom, B. C.; van Leeuwen, M. S.; Noordzij, J.

    1994-01-01

    AIMS: To determine whether the new technique of CT-angiography was accurate in displaying the complex anatomy of the aorta and its major branches. METHODS: Seventeen patients with a variety of aortic pathology were examined. Using a spiral CT-scanner a volumetric scan was made during injection of

  13. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  14. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Almutairi, Abdulrahman Marzouq D.

    2010-01-01

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  15. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  16. First experience of combined cardiac PET/64-detector CT angiography with invasive angiographic validation

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Endozo, Raymondo; Menezes, Leon J.; Prvulovich, Elizabeth; Ell, Peter J.; Speechly-Dick, Marie-Elsya; McEwan, Jean; Pugliese, Francesca; Habib, Said B.

    2009-01-01

    Despite modern CT systems and expert evaluators, the diagnostic performance of coronary CT angiography is limited by overestimation of vessel stenosis which reduces the positive predictive value (PPV) of the test. The aim of this study was to evaluate the performance of combined cardiac PET/64-detector CT angiography. Included in this retrospective study were 33 consecutive patients (5 women, 28 men; mean age 61.6 years, range 47-87 years, mean BMI 27.3±5.2 kg/m 2 ) with clinically suspected flow-limiting coronary artery disease who underwent combined cardiac PET/64-detector CT angiography and invasive angiography. Combined PET/CT images were reported by an experienced dual-accredited radiologist/nuclear physician. An experienced cardiac CT radiologist re-read the CT images without PET. Stenotic disease was defined as >50% vessel narrowing. Invasive coronary angiography was used as a reference standard. Local ethics committee approval and patient consent were obtained. CT angiography (without PET data) was concordant with invasive angiography in 31/33 patients and at a patient level, the sensitivity in detecting significant coronary artery lesions was 100%, the specificity was 82%, the PPV was 92% and the negative predictive value (NPV) was 100%. Using combined PET/CT angiography the findings were concordant with invasive angiography in 32/33 patients and at a patient level, the sensitivity was 96%, the specificity was 100%, the PPV was 100% and the NPV was 91%. The use of integrated cardiac PET/64-detector CT angiography is feasible and appears to improve some aspects of the diagnostic performance of 64-detector coronary artery angiography in detecting coronary artery disease. (orig.)

  17. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  18. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  19. Vascular imaging with spiral CT. The way to CY angiography

    International Nuclear Information System (INIS)

    Prokop, M.; Schaefer, C.; Kalender, W.A.; Polacin, A.; Galanski, M.

    1993-01-01

    Spiral CT is a technique that allows for high-quality two-dimensional angiographic projections and 3D imaging of vascular structures. The authors present the technical and methodological principles of the technique, including scan parameters and parameters of contrast application for various clinical imaging tasks. They present their experience with over 150 clinical cases using spiral CT angiography. Suitable applications of this technique include cogenital anomalies, aneurysms, dissections, stenoses, thrombi and vascular tumor involvement. Given a problem-adapted examination technique, pathologic changes in vessels of as little as 2 mm can be visualized. In some cases with complex vascular anatomy, spiral CT angiography can be superior to arterial angiography. (orig.) [de

  20. Development of test bolus tracking method and usefulness in coronary CT angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Takayoshi; Takahashi, Daichi

    2009-01-01

    The test bolus tracking (TBT) method is a new injection method of contrast medium that we developed. The TBT method is an injection technique that continuously performs the test bolus injection and the main bolus injection, such that the best acquisition of scan timing and the improvement of examination efficiency can be expected. We compared the TBT method and the test injection method by coronary CT angiography. The results demonstrated that the contrast enhancement of the coronary arteries was high and the variation of the CT value was also small in the TBT method. When the scan timing expected by the TI method and the TBT method were compared, it was different of two seconds or more by the case with 43%. However, the variation of CT value was small for the TBT method in these cases. Therefore, the TBT method is a very useful method for coronary CT angiography (CCTA). (author)

  1. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    International Nuclear Information System (INIS)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G.; Hamami, M.E.; Poeppel, T.; Bockisch, A.; Ertle, J.; Hilgard, P.

    2010-01-01

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 ± 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  2. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  3. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    International Nuclear Information System (INIS)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo

    2013-01-01

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  4. Role of plain radiography and CT angiography in the evaluation of obstructed total anomalous pulmonary venous connection

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Quanli; Pa, Mier; Hu, Xihong; Wang, Junbo [Children' s Hospital, Fudan University, Department of Radiology, Shanghai (China)

    2013-07-15

    Obstructed total anomalous pulmonary venous connection (TAPVC) is frequently misdiagnosed as pulmonary disease and without operative correction early death is common. It is important to make a correct diagnosis before surgery. The purpose of this study was to describe the chest radiographic features of obstructed TAPVC and compare CT angiography with transthoracic echocardiography in the evaluation of obstructed TAPVC. Eighteen children with obstructed TAPVC were assessed. Their clinical and imaging data were retrospectively reviewed. The characteristic radiographic findings were analyzed and compared with surgical results, and the diagnostic accuracy of CT angiography and transthoracic echocardiography was evaluated in terms of pulmonary venous drainage and obstruction detection. The common radiographic features included pulmonary venous congestion or edema or both (16 of 18 cases, 89%), and absence of cardiomegaly (12 of 18 cases, 67%). CT angiography correctly diagnosed TAPVC and clearly revealed the draining sites in all children (five with supracardiac TAPVC, three with cardiac TAPVC, eight with infracardiac TAPVC and two with mixed TAPVC). The diagnostic agreement between CT angiography and surgery was 100%. Transthoracic echocardiography only correctly revealed the draining sites in 11 children (5 with supracardiac TAPVC, 2 with cardiac TAPVC and 4 with infracardiac TAPVC). The diagnostic agreement between transthoracic echocardiography and surgery was 61%. The diagnostic accuracy of CT angiography was higher than that of transthoracic echocardiography (P = 0.0156). Thirty-four sites of obstruction were correctly detected by CT angiography (11 in the mediastinum, 1 at the diaphragmatic level, 9 below the diaphragm and 13 stenotic individual pulmonary veins in the lung). The diagnostic agreement between CT angiography and surgery was 92%. Transthoracic echocardiography only correctly detected 15 sites of obstruction (11 in the mediastinum, 1 at the

  5. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  6. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  7. Intraarterial CT Angiography Using Ultra Low Volume of Iodine Contrast – Own Experiences

    International Nuclear Information System (INIS)

    Garcarek, Jerzy; Kurcz, Jacek; Guziński, Maciej; Banasik, Mirosław; Miś, Marcin; Gołębiowski, Tomasz

    2015-01-01

    High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1–2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6–8 mL of Iodixanol (320 mg/mL) diluted with saline to 18–24 mL was administered at a speed of 4–5 mL/s. Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of

  8. Usefulness of CT angiography after metallic stent implantation of the internal carotid artery

    International Nuclear Information System (INIS)

    Yoon, Man Won; Kim, Hyeon Chul; Kim, Jae Kyu; Seo, Jeong Jin; Jeong, Gwang Woo; Kang, Heoung Keun

    1999-01-01

    To evaluate the usefulness of CT angiography in patients with implantation of metallic stent for stenosed internal carotid artery. Seven patients with atherosclerotic stenosis of the internal carotid artery underwent metallic stent implantation. All were male and their ages ranged from 36 to 69 years. A total of seven stents were placed in the internal carotid artery in five patients and in the carotid bifurcation in two. Spiral CT scans were obtained and CT angiographic images were reconstructed using MPR or curved MPR techniques at a workstation. The interval between CT and conventional angiography did not exceed six days except in one patient, in whom it was 61days. CT and conventional angiography were compared for stent position with respect to the carotid bifurcation, stent deformation, intraluminal filling defect, and luminal caliber and outflow. Luminal patency of the implanted stent was measured according to NASCET(North American Symptomatic Carotid Endarterectomy Trial) criteria, and statistically processed (p>.05). The presence or absence of intrastent thrombus and vascular wall calcification was determined using axial source images. In all patients, CT angiographic findings matched those obtained by conventional angiography. Complications such as migration or deformation of an implanted stent, intraluminal filling defect, change of luminal caliber or outflow of implanted stent were not observed in any patient. In two studies in which Wilcoxon signed rank test was used, degree of stent expansion correlated closely(p=0.237). Axial source images showed that in no patient was an intrastent thrombus present, though in five, vascular wall calcification of internal carotid arteries outside the stent was noted. CT angiography is useful for the assessment of positional change, occlusion, and luminal patency of a stent-implanted internal carotid artery

  9. Conventional and CT angiography in children: dosimetry and dose comparisons

    International Nuclear Information System (INIS)

    Frush, Donald P.; Yoshizumi, Terry

    2006-01-01

    Tremendous advances have been made in imaging in children with both congenital and acquired heart disease. These include technical advances in cardiac catheterization and conventional angiography, especially with advancements in interventional procedures, as well as noninvasive imaging with MR and CT angiography. With rapid advances in multidetector CT (MDCT) technology, most recently 64-detector array systems (64-slice MDCT), have come a number of advantages over MR. However, both conventional and CT angiography impart radiation dose to children. Although the presence of radiation exposure to children has long been recognized, it is apparent that our ability to assess this dose, particularly in light of the rapid advancements, has been limited. Traditional methods of dosimetry for both conventional and CT angiography are somewhat cumbersome or involve a potential for substantial uncertainty. Recent developments in dosimetry, including metal oxide semiconductor field effect transistors (MOSFET) and the availability of anthropomorphic, tissue-equivalent phantoms have provided new opportunities for dosimetric assessments. Recent work with this technology in state-of-the-art cardiac angiography suites as well as with MDCT have offered direct comparisons of doses in infants and children undergoing diagnostic cardiac evaluation. It is with these dose data that assessment of risks, and ultimately the assessment of risk-benefit, can be better achieved. (orig.)

  10. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    International Nuclear Information System (INIS)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung

    1987-01-01

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed

  11. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  12. Likelihood of aneurysmal subarachnoid haemorrhage in patients with normal unenhanced CT, CSF xanthochromia on spectrophotometry and negative CT angiography.

    Science.gov (United States)

    Rana, A K; Turner, H E; Deans, K A

    2013-01-01

    Patients with suspected subarachnoid haemorrhage, a normal noncontrast computed tomography (CT) and cerebrospinal fluid (CSF) evidence of haemoglobin breakdown products often undergo CT angiography (CTA). If this is normal, then invasive catheter angiography may be offered. In current clinical practice, haemoglobin breakdown products are detected by spectrophotometry rather than visible xanthochromia, and CTA is performed on multidetector scanners. The aim of this study was to determine if such patients should still have a catheter angiography, given the associated risks. Patients positive for CSF spectrophotometry (n=26) were retrospectively identified from the clinical biochemistry information system and imaging data from the electronic radiology records were reviewed. Discharge letters were consulted to relate the biochemistry and radiology results to the final diagnosis. 15 patients with CT angiography were found. Nine patients had normal CT angiography. No causative aneurysms had been missed. One patient had small, coincidental aneurysms missed on initial reading of the CTA. The likelihood of a clinically significant aneurysm in a patient who is CT negative, lumbar puncture positive and CTA negative is low. Double reporting of negative CT angiograms may be advisable.

  13. First results of spiral CT angiography in the evaluation of carotid artery stenosis

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Brossmann, J.; Grabener, M.; Voss, C.; Heller, M.

    1995-01-01

    To determine the value of spiral CT angiography in Maximum Intensity Projection (MIP)-technique for evaluation of carotid artery stenosis. A comparison of the MIP technique with intraarterial DSA was done in 24 patients with 40 stenoses. Quantification of stenosis was determined according to the NASCET study: mild (0-29%), moderate (30-69%), severe (70-99%) and occlusion (100%). Totally the correlation of spiral CT angiography with DSA was 80% (r=0.93; p=0.0001). In the moderate stenosis group (r=1; p=0.1573), severe stenosis group (r=0.89; p=0.002) and the occlusion group (r=1; p=0.0009) there was a good correlation with DSA. In the mild stenosis group (r=0.55; p=0.0704) correlation of spiral CT angiography with DSA was poor. Spiral CT angiography allows an excellent delineation of calcifications. Tandem lesions and collateral flow cannot be shown with spiral CT angiography. (orig./MG) [de

  14. Appearance and impact of post-operative intracranial clips and coils on whole-brain CT angiography and perfusion

    International Nuclear Information System (INIS)

    Roach, Cayce J.; Russell, Cheryl L.; Hanson, Eric H.; Bluett, Brent; Orrison, William W.

    2012-01-01

    Background: To evaluate the effect of vascular clips and endovascular coils placed for intracranial aneurysms and arteriovenous malformations on whole-brain computed tomography (CT) angiography and perfusion. Methods: A 320-detector row dynamic volume CT system imaged 11 patients following surgical placement of vascular clips or endovascular coils. The extent of clip and coil subtraction by automated software was evaluated using CT digital subtraction angiography and CT perfusion. Impact on CT perfusion values by retained intracranial devices was compared to age- and gender-matched controls. Results: Clip and coil subtraction on CT angiography was graded as good in 8 and moderate in 3 cases. A residual neck and additional aneurysm were noted in 1 of 11 patients. Post-procedural axial slice level CT perfusion values decreased in reliability with increasing proximity to the metallic devices secondary to beam hardening. However, the intracranial devices did not affect axial slice level CTP values of cerebral blood volume, cerebral blood flow and mean transit time outside of the level of the device. Time to peak values was globally decreased outside of the immediate vascular intervention region. Conclusions: Advances in CT technology have provided clinically useful subtraction of intracranial clips and coils. While CT perfusion values were altered in device subtraction areas and within beam hardening artifact areas; they can provide valuable postoperative information on whole-brain hemodynamics. In selected cases, the combination of CT angiography and whole-brain CT perfusion can offer an alternative to conventional angiography that is a more invasive option.

  15. Diagnostic accuracy of high-definition CT coronary angiography in high-risk patients

    International Nuclear Information System (INIS)

    Iyengar, S.S.; Morgan-Hughes, G.; Ukoumunne, O.; Clayton, B.; Davies, E.J.; Nikolaou, V.; Hyde, C.J.; Shore, A.C.; Roobottom, C.A.

    2016-01-01

    Aim: To assess the diagnostic accuracy of computed tomography coronary angiography (CTCA) using a combination of high-definition CT (HD-CTCA) and high level of reader experience, with invasive coronary angiography (ICA) as the reference standard, in high-risk patients for the investigation of coronary artery disease (CAD). Materials and methods: Three hundred high-risk patients underwent HD-CTCA and ICA. Independent experts evaluated the images for the presence of significant CAD, defined primarily as the presence of moderate (≥50%) stenosis and secondarily as the presence of severe (≥70%) stenosis in at least one coronary segment, in a blinded fashion. HD-CTCA was compared to ICA as the reference standard. Results: No patients were excluded. Two hundred and six patients (69%) had moderate and 178 (59%) had severe stenosis in at least one vessel at ICA. The sensitivity, specificity, positive predictive value, and negative predictive value were 97.1%, 97.9%, 99% and 93.9% for moderate stenosis, and 98.9%, 93.4%, 95.7% and 98.3%, for severe stenosis, on a per-patient basis. Conclusion: The combination of HD-CTCA and experienced readers applied to a high-risk population, results in high diagnostic accuracy comparable to ICA. Modern generation CT systems in experienced hands might be considered for an expanded role. - Highlights: • Diagnostic accuracy of High-Definition CT Angiography (HD-CTCA) has been assessed. • Invasive Coronary angiography (ICA) is the reference standard. • Diagnostic accuracy of HD-CTCA is comparable to ICA. • Diagnostic accuracy is not affected by coronary calcium or stents. • HD-CTCA provides a non-invasive alternative in high-risk patients.

  16. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  17. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  18. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  19. Assessment of hepatic arterial variation using multidetector helical CT-angiography

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Lee, Jun Woo; Jun, Woong Bae; Lee, Suk Hong

    2001-01-01

    To evaluate the anatomy of the hepatic artery and normal variants using oblique thick-slab maximal intensity projection (MIP) 3-D CT angiography and multidetector helical CT technology. In 70 patients, axial three-phase CT together with multidetector helical CT and a nonionic contrast agent was used to evaluate liver disease. During the early arterial phase, the parameters were as follow: slice thickness, 2.5 mm; table speed, 15 mm/rotation, pitch, 6; contrast material, 4 ml/sec; total 120 ml. Using the MIP technique and an Advantage window voxtal 3.03 system (GE), the images obtained were reconstructed as 3D angiograms. In each case, the arterial anatomy and its variants were recorded. A typical anatomy was found in 53 cases (75.7%). Common variants were a left hepatic artery arising from the left gastric artery(8 cases, 11.4 %) and a right hepatic artery arising from the superior mesenteric artery(3 cases, 4.3%). Other variant cases were right hepatic artery arising from the gastroduodenal artery(2 cases, 2.9%), a proper hepatic artery arising from the left gastric artery (1 case, 1.4%), a hepatomesenteric trunk (1 case), a hepatogastric/splenomesenteric trunk(1 case), and a celiomesenteric trunk (1 case). 3-D hepatic angiography using multidetector helical CT technology is non-invasive and as accurate as conventional angiography for the evaluation of hepatic arterial anatomy. It is thus considered that 3-D CT angiography is very helpful for the evaluation of hepatic arterial anatomy prior to liver surgery such as transplantation or the treatment of hepatocellular carinoma

  20. Carbon dioxide hepatic arterial DSA and CT angiography in swine model

    International Nuclear Information System (INIS)

    Tan Huaqiao; Hu Hongjie; Huang Wenxin; Zhang Shizheng; Dong Yonghua; Zhou Dachun

    2005-01-01

    Objective: To evaluate the imaging findings of carbon dioxide hepatic arterial DSA and CT angiography in normal swine. Methods: In general anaesthesia, hepatic arterial DSA was performed with 10 ml iodinated contrast medium (5 ml/s, 10 ml) in 5 normal swine, and then repeated hepatic arterial CO 2 -DSA was performed with a total of 30-50 ml CO 2 injected by manually operated syringe at the velocity of 5-8 ml/s, followed by CO 2 -CT angiography. All the swine were sacrificed after the procedure, the selective hepatic segments were removed, and pathological examination was carried out. The radiological features of hepatic arterial DSA with iodinated contrast medium and CO 2 and CT angiography with CO 2 were analyzed. The ability of showing the arterio-venous shunt was compared. Results: Hepatic arterio-portal shunt was found in the advanced arterial phase of CO 2 -DSA in three of five swine, which was furthermore demonstrated by CO 2 -CT angiography, but iodinated contrast medium DSA showed no arterio-portal shunt in all swine. The gaseous CO 2 in portal vein was absorbed within 1-3 minutes. No CO 2 shunted into the hepatic vein during CO 2 -DSA and CO 2 -CTA. Histology didn't reveal any abnormal changes caused by CO 2 shunt in the swine liver. Conclusion: (1) Hepatic arterial CO 2 -DSA and CO 2 -CTA can reveal arterio-portal shunt that isn't seen with iodinated contrast medium, the gaseous CO 2 in portal vein was absorbed within 1-3 minutes. (2) The gaseous CO 2 can't shunt into hepatic vein when the hepatic artery is perfused with CO 2 in normal swine. (authors)

  1. Hepatic arterial supply in 1297 CT-angiographies; Die arterielle Leberversorgung in 1297 CT-Angiografien

    Energy Technology Data Exchange (ETDEWEB)

    Loeschner, C.; Kausche, S.; Teichgraeber, U. [Jena University Hospital, Jena (Germany). Dept. of Radiology; Nagel, S.N. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology

    2015-04-15

    Analysis, evaluation and classification of hepatic arterial supply variants and determination of their frequency distribution in CT-angiographies. CT-angiographies of 1,568 patients were evaluated retrospectively for the period between January 1, 2010 and August 30, 2012. The hepatic arterial anatomy was assessed and categorized according to Michels's classification. So far unclassified variants were considered separately. Results: CT-angiographies of 1297 patients were included in the study. Type I according to Michels was seen in 937 cases (72.2%), followed by type V in 114 patients (8.8%) and type III in 83 patients (6.4%). Type X could not be found in any of the patients. Not yet classified variants were discovered in 26 patients. The most frequent variant in this connection was a right hepatic artery originating from the superior mesenteric artery with the left hepatic artery originating from the left gastric artery (n=10). Michels's classification could be largely confirmed on the basis of a radiologically examined patient population. Not yet classified variants were categorized into subgroups of the existing classification.

  2. Budd-Chiari syndrome: dynamic enhancement findings with multi-slice helical CT and CT angiography analysis

    International Nuclear Information System (INIS)

    Meng Xiaochun; Shan Hong; Zhu Kangshun; Xu Chuan; Zhang Jiansheng; Liu Lingyun; Ye Binbin

    2005-01-01

    Objective: To investigate the dynamic enhancement regulations of liver and their mechanism in Budd-Chiari syndrome (BCS) by using multi-slice CT and evaluate the value of CT angiography in the diagnosis of BCS. Methods: 28 cases with BCS confirmed by digital subtraction angiography (DSA) were retrospectively analyzed. All patients underwent dynamic enhancement examinations with multi-slice CT within 1 week before DSA. The relevant vessels were reconstructed respectively with MIP, VR and MPR. Compared with the results of DSA, we analyzed the dynamic enhancement regulations of liver in BCS, estimated the value of dynamic enhancement CT exams and CTA techniques in judging the obstruction level and showing collateral vessels. Results: Of all 28 cases, CT correctly showed the obstruction level in 26 cases, and 2 had incorrect results which proved to be membranous obstruction of the inferior vena cava superior to diaphragm. In 22 cases with hepatic vein obstructions, hepatic parenchyma displayed typical patchy enhancement in 19, atypical patchy enhancement in 3.8 cases among these showed benign nodules. Simultaneously, CT showed stenosis and rigidity of portal vein branches in 20, enlargement of hepatic artery in 14, hepatic collateral vessels in 20 out of 22 cases. In 6 cases with simple obstruction of inferior vena cava, hepatic changes were not found. Collateral circulations in or out of liver corresponded to the obstruction level. Conclusion: Dynamic enhancement examinations with multi-slice CT can correctly reflect the hepatic hemodynamic changes. Transverse images, combined with CTA, can explicitly display the obstruction level of vascular lesions and collateral circulations in BCS. (authors)

  3. The psychological impact of test results following diagnostic coronary CT angiography.

    Science.gov (United States)

    Devcich, Daniel A; Ellis, Christopher J; Broadbent, Elizabeth; Gamble, Greg; Petrie, Keith J

    2012-11-01

    Coronary computed tomography (CT) angiography is an advanced cardiac imaging test commonly used for diagnosing early signs of ischemic heart disease. Despite its importance in cardiology, little is known about its psychological effect on patients. The present study sought to examine these effects in relation to illness perceptions, cardiac health behavior intentions, and subsequent health behaviors. Forty-five nonacute cardiac patients who were referred for diagnostic coronary CT angiography completed questionnaires prior to testing and following the receipt of test results, at which point illness perceptions and intentions to take cardiac medication, as well as diet and exercise intentions were measured. Exercise and dietary behaviors were measured at follow-up 6 weeks later. Changes on these variables were then compared between patients diagnosed with normal arteries and patients diagnosed with diseased arteries. Compared to positive-testing patients, patients with normal test results reported significant changes toward more positive illness perceptions following testing, with improvements in emotional effect of illness, illness concern, consequences, and personal control of illness. The illness perception of treatment control was seen as more important among positive-testing patients, whereas both groups reported increases in illness coherence. Health behavior intentions (cardiac medication intentions and exercise intentions) increased for positive-testing patients only, as did physical activity at follow-up. Diagnosis-dependent psychological effects can be detected following coronary CT angiography. These effects have important implications for patient health and health care in diagnostic contexts, and the results from this study can be used to guide further research in this area.

  4. Coronary CT angiography: How should physicians use it wisely and when do physicians request it appropriately?

    International Nuclear Information System (INIS)

    Sun Zhonghua; Aziz, Yang Faridah Abdul; Ng, Kwan-Hoong

    2012-01-01

    Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease due to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with 64- and more slice CT scanners and in selected patients, coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. Although the tremendous contributions of coronary CT angiography to cardiac imaging are acknowledged, appropriate use of cardiac CT as the first line technique by physicians has not been well established. Optimal selection of cardiac CT is essential to ensure acquisition of valuable diagnostic information and avoid unnecessary invasive procedures. This is of paramount importance since cardiac CT not only involves patient risk assessment, prediction of major cardiac events, but also impacts physician decision-making on patient management. Applications of CT in cardiac imaging include coronary artery calcium scoring for predicting the patient risk of developing major cardiac events, followed by coronary CT angiography which is commonly used to determine the diagnostic and prognostic accuracy in the coronary artery disease. This review presents an overview of the applications of CT in cardiac imaging in terms of coronary calcium scoring and coronary CT angiography. Judicious use of both cardiac CT tools will be discussed with regard to their value in different patient risk groups with the aim of identifying the appropriate criteria for choosing a cardiac CT modality. An effective diagnostic pathway is finally recommended to physicians for appropriate selection of cardiac CT in clinical practice.

  5. Bolus timing in high-pitch CT angiography of the aorta

    International Nuclear Information System (INIS)

    Beeres, Martin; Loch, Matthias; Schulz, Boris; Kerl, Matthias; Al-Butmeh, Firas; Bodelle, Boris; Herrmann, Eva; Gruber-Rouh, Tatjana; Lee, Clara; Jacobi, Volkmar; Vogl, Thomas J.

    2013-01-01

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished

  6. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki

    1996-01-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  7. Helical CT for emergency patients with cerebrovascular diseases. Diagnosis of cerebral aneurysms with subarachnoid hemorrhage (SAH) by three-dimensional CT angiography (3D-CTA)

    Energy Technology Data Exchange (ETDEWEB)

    Matsumoto, Masato; Satoh, Naoki; Kobayashi, Touru; Kodama, Namio; Nakano, Masayuki; Watanabe, Youichi; Fujii, Masayuki [Fukushima Medical School (Japan)

    1996-05-01

    Recently, the usefulness of three-dimensional CT angiography (3D-CTA) using helical CT has been reported. Although 3D-CTA has been applied for neurosurgical diseases, especially for surgical planning, it has not done for emergency patients because of the long time required for image reconstruction and location of a helical CT scanner. We studied emergency patients with SAH, and compared the 3D-CTA with angiography and surgical findings, using TOSHIBA X vigor. Twenty-two patients with SAH were evaluated. The helical CT was performed for 55 seconds with a bolus injection of 90 ml non-ionic, iodinated contrast medium at a rate of 3 ml/sec with a delay of 20 sec. Angiography was carried out immediately after the helical CT. Eighteen of 22 cases were operated on urgently. We were able to create the 3D-CTA in about 7 minutes, and diagnose aneurysms by the 3D-CTA before angiography. The 3D-CTA was able to demonstrate 30 of 31 aneurysms including 9 unruptured aneurysms. An unruptured internal carotid-posterior communicating artery aneurysm 1.3 mm in diameter and associated with a ruptured aneurysm was not detected by either the 3D-CTA or angiography. On the other hand, an unruptured Acom aneurysm 0.8 mm in diameter and associated with a ruptured aneurysm could be detected by the: 3D-CTA, but not by angiography. The 3D-CTA gave us useful information concerning the anatomical relationship of the aneurysm, its neck and parent artery, and the surrounding branches. There were no complications or side effects associated with the helical CT scan. Although the 3D-CTA requires further development of visualization of small arteries less than 1 mm in diameter, such as perforating arteries, subtraction technique of bony structure, and a method for checking cervical arteries, it is useful for diagnosis of emergency patients with SAH and urgent operations. We believe that an operation might be performed by only the 3D-CTA without the angiography in the near future. (author)

  8. Assessment of anemia during CT pulmonary angiography

    International Nuclear Information System (INIS)

    Jung, Caroline; Groth, Michael; Bley, Thorsten A.; Henes, Frank O.; Treszl, András; Adam, Gerhard; Bannas, Peter

    2012-01-01

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  9. Assessment of anemia during CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Caroline, E-mail: cjung@uke.de [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Groth, Michael; Bley, Thorsten A.; Henes, Frank O. [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Treszl, András [Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany)

    2012-12-15

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  10. CT pulmonary angiography using 64-row multi-slice spiral CT: a comparative study in low tube voltage setting combined with personalized contrast agent application

    International Nuclear Information System (INIS)

    Zhou Xuhui; Peng Zhenpeng; Zheng Lili; Li Shurong; Yang Zhiyun; Meng Quanfei; Chen Xing

    2009-01-01

    Objective: To investigate the feasibility of the low tube voltage setting and personalized contrast agent application in 64-row multi-slice spiral CT pulmonary angiography. Methods: Ninety patients with high risk of pulmonary artery embolism were sequentially enrolled in the study and divided into 3 groups employing completely randomized design: (l)Regular group included 30 patients using 120 kV and fixed dose of 70 ml contrast agent, (2)Another 30 patients were in 120 kV group, using 120 kV and the contrast amount was determined according to the patient weight (1.0 ml/kg), (3) The remaining 30 patients were included in 100 kV group, using 100 kV and the contrast amount was also determined according to the patient weight(1.0 ml/kg). Administration of contrast agent was completed within 20 seconds for all the patients, followed by 20 ml of saline. The objective and subjective indexes for assessing CT image quality, CT dose index volume (CTDIvol) and effective received dose (ERD) were compared between 120 kV group and 100 kV group; then the contrast media volume, injection rate, objective CT image indexes and subjective indexes for image quality was compared between the 100 kV group and regular group. The variance analysis and post hoc test were employed for the statistical analysis. Results: Compared with 120 kV group (3.4±0.7), the image quality of 100 kV group (5.2±1.8) had higher noise (52.9%), but subjective index for the image quality demonstrated no differences (q=0.272, P=0.063) in mediastinum window while CTDIvol and ERD decreased for 34.9% [(9.5±0.0) vs (14.6±0.0) mGy] and 36.8% [(3.8±0.6) vs (2.4±0.4) mSv]. The mean CT values on pulmonary artery of 100 kV group[ (269.2±54.7) HU] were 13.4% (31.8/237.4) higher than the 120 kV group [(237.4±62.9)HU], but there was no statistical differences compared to normal group (q=0.172,P=0.260). Conclusion: Using low kV setting (100 kV) to reduce radiation dose is proved to be effective and feasible in 64-MSCT

  11. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  12. Cost effectiveness of coronary angiography and calcium scoring using CT and stress MRI for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Dewey, Marc; Hamm, Bernd

    2007-01-01

    We compared the cost effectiveness of recent approaches [coronary angiography and calcium scoring using computed tomography (CT) and stress magnetic resonance imaging (MRI)] to the diagnosis of coronary artery disease (CAD) with those of the traditional diagnostic modalities [conventional angiography (CATH), exercise ECG, and stress echocardiography] using a decision tree model. For patients with a 10% to 50% pretest likelihood of coronary artery disease, non-invasive coronary angiography using CT was the most cost effective approach, with costs per correctly identified CAD patient of EUR4,435 (10% likelihood) to EUR1,469 (50% likelihood). Only for a pretest likelihood of 30% to 40% was calcium scoring using CT more cost effective than any of the traditional diagnostic modalities, while MRI was not cost effective for any pretest likelihood. At a pretest likelihood of 60%, CT coronary angiography and CATH were equally effective, while CATH was most cost effective for a pretest likelihood of at least 70%. In conclusion, up to a pretest likelihood for coronary artery disease of 50%, CT coronary angiography is the most cost-effective procedure, being superior to the other new modalities and the most commonly used traditional diagnostic modalities. With a very high likelihood for disease (above 60%), CATH is the most effective procedure from the perspective of society. (orig.)

  13. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  14. Diagnosis of arterial sequestration using multidetector CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu Hong, E-mail: yuhong.2002@hotmail.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Li Huimin, E-mail: lihuiminphd@163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Liu Shiyuan, E-mail: cjr.liushiyuan@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China); Xiao Xiangsheng, E-mail: cjr.xxsh@vip.163.com [Department of Radiology, Changzheng Hospital, Second Military Medical University, Shanghai, 200003 (China)

    2010-11-15

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  15. Diagnosis of arterial sequestration using multidetector CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Liu Shiyuan; Xiao Xiangsheng

    2010-01-01

    Background: Arterial sequestration is a rare congenital disorder. The diagnostic evaluation of this condition using multidetector computerized tomography (MDCT) has not been described previously. The purpose of this study was to describe the characteristic features of this disorder and to assess the use of MDCT in visualizing the characteristic anatomic features. Methods: We retrospectively reviewed the records of seven patients with anomalous systemic blood supply to left lower lobe of the lung. All the patients had undergone MDCT angiography. To evaluate the lung parenchyma, bronchial branching pattern, and vascular anatomy, four series of images were systematically reconstructed as follows: contiguous transverse CT scans viewed at mediastinal and pulmonary window settings, oblique coronal and sagittal maximum intensity projections (MIP), multiplanar reconstruction (MPR), and three-dimensional volume-rendered images (VR) of airway and thoracic vascular structures. Results: All 7 cases had isolated and tortuous arterial anatomy from the descending thoracic aorta to the basal segment of the left lower lobe; however, variable distribution of branches was observed. Characteristic findings of anomalous systemic arterial (ASA) supply were distinct from those seen in other pulmonary sequestration syndromes and were well visualized by the use of noninvasive MDCT. Conclusion: Complex CT findings allow clear imaging of arterial sequestration and the ASA blood supply; MDCT angiography has demonstrated its value and accuracy in diagnosing this condition, obviating the use of digital subtraction angiography and magnetic resonance angiography for the diagnosis of arterial sequestration.

  16. Evaluation of the relationship between extremity soft tissue sarcomas and adjacent major vessels using contrast-enhanced multidetector CT and three-dimensional volume-rendered CT angiography - A preliminary study

    International Nuclear Information System (INIS)

    Li, YangKang; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo; Zheng, Yu; Wei, XiaoLong; Cheng, Ying; Liu, GuoRui

    2013-01-01

    Background: Accurate description of the relationship between extremity soft tissue sarcoma and the adjacent major vessels is crucial for successful surgery. In addition to magnetic resonance imaging (MRI) or in patients who cannot undergo MRI, two-dimensional (2D) postcontrast computed tomography (CT) images and three-dimensional (3D) volume-rendered CT angiography may be valuable alternative imaging techniques for preoperative evaluation of extremity sarcomas. Purpose: To preoperatively assess extremity sarcomas using multidetector CT (MDCT), with emphasis on postcontrast MDCT images and 3D volume-rendered MDCT angiography in evaluating the relationship between tumors and adjacent major vessels. Material and Methods: MDCT examinations were performed on 13 patients with non-metastatic extremity sarcomas. Conventional CT images and 3D volume-rendered CT angiography were evaluated, with focus on the relationship between tumors and adjacent major vessels. Kappa consistency statistics were performed with surgery serving as the reference standard. Results: The relationship between sarcomas and adjacent vessels was described as one of three patterns: proximity, adhesion, and encasement. Proximity was seen in five cases on postcontrast CT images or in eight cases on volume-rendered images. Adhesion was seen in three cases on both postcontrast CT images and volume-rendered images. Encasement was seen in five cases on postcontrast CT images or in two cases on volume-rendered images. Compared to surgical results, postcontrast CT images had 100% sensitivity, 83.3% specificity, 87.5% positive predictive value, 100% negative predictive value, and 92.3% accuracy in the detection of vascular invasion (κ = 0.843, P = 0.002). 3D volume-rendered CT angiography had 71.4% sensitivity, 100% specificity, 100% positive predictive value, 75% negative predictive value, and 84.6% accuracy in the detection of vascular invasion (κ = 0.698, P = 0.008). On volume-rendered images, all cases

  17. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the

  18. Comparison of X-ray radiation exposure during digital subtraction angiography (DSA) and multislice CT angiography (CTA)

    International Nuclear Information System (INIS)

    Bai, Mei; Liu, Bin; Zheng, Junzheng

    2008-01-01

    Full text: Purpose: To compare radiation risk during digital subtraction angiography (DSA) and CT angiography (CTA). Materials and methods: Eighty patients randomly divided into two groups of 40 patients each, were evaluated for coronary atherosclerotic heart disease with 64-slice spiral CT angiography and DSA respectively. For CTA group we divided patients into two subgroups: regular mode and ECG modulation mode. Matix of thermoluminescent dosimeters (TLDs) were placed on patients' skin surface during each examination to access peak skin dose (PSD). A male ART phantom was equipped with TLDs in six different positions to assess achievable organ dose. Effective dose was calculated by commercially available computer programs. Results: For DSA, PSD was 64mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 11.07mGy, 5.87mGy, 1.42mGy, 2.11mGy, 6.76mGy and 0.001mGy respectively, and effective dose was 4mSv. For regular mode CTA, PSD was 74.5mGy, and CTD vol was 37.9mGy. Phantom organ dose for lung, heart, stomach, liver, kidney and brain were 58mGy, 64.2mGy, 6.6mGy, 9.9mGy, 2.7mGy, 0.072mGy respectively, and effective dose was 16mSv. For ECG modulation mode, PSD was 50.9mGy, and CTD vol was 26.3mGy. Conclusion: According to measured PSD value, deterministic radiation risk for regular mode CTA was little higher than DSA. However for stochastic radiation risk which can be indicated by organ dose and effective dose, regular mode CTA was much higher than DSA. Comparing with regular mode, ECG modulation mode can effectively reduce both stochastic and deterministic radiation risk. (author)

  19. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  20. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    International Nuclear Information System (INIS)

    Pugliese, Francesca; Krestin, Gabriel P.; Mollet, Nico R.A.; DeFeyter, Pim J.; Runza, Giuseppe; Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo; Malagutti, Patrizia; Cademartiri, Filippo

    2006-01-01

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as ≥ 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  1. TRIAGE OF PATIENTS TO ANGIOGRAPHY FOR DETECTION OF AORTIC RUPTURE AFTER BLUNT CHEST TRAUMA - COST-EFFECTIVENESS ANALYSIS OF USING CT

    NARCIS (Netherlands)

    HUNINK, MGM; BOS, JJ

    OBJECTIVE. The purpose of this study was to evaluate the cost-effectiveness of dynamic chest CT, compared with plain chest radiography and immediate angiography, in deciding when angiography should be performed in hemodynamically stable patients with suspected aortic rupture after blunt chest

  2. Feasibility of coronary calcium and stent image subtraction using 320-detector row CT angiography

    DEFF Research Database (Denmark)

    Fuchs, Andreas; Kühl, J Tobias; Chen, Marcus Y

    2015-01-01

    BACKGROUND: The reader confidence and diagnostic accuracy of coronary CT angiography (CCTA) can be compromised by the presence of calcified plaques and stents causing blooming artifacts. Compared to conventional invasive coronary angiography (ICA), this may cause an overestimation of stenosis....... We defined target segments on CCTAconv as motion-free coronary segments with calcification or stent and low reader confidence. The effect of CCTAsub was assessed. No approval from the ethics committee was required according to Danish law. RESULTS: A total of 76 target segments were identified...

  3. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  4. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols

    International Nuclear Information System (INIS)

    Neefjes, Lisan A.; Kate, Gert-Jan R. ten; Rossi, Alexia; Nieman, Koen; Papadopoulou, Stella L.; Dharampal, Anoeshka S.; Dedic, Admir; Feyter, Pim J. de; Mollet, Nico R.; Genders, Tessa S.S.; Hunink, M.G.M.; Schultz, Carl J.; Weustink, Annick C.; Dijkshoorn, Marcel L.; Straten, Marcel van; Cademartiri, Filippo; Krestin, Gabriel P.

    2013-01-01

    To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose. circle 128-slice dual-source CT coronary angiography offers several different acquisition protocols. (orig.)

  5. Dose modulated retrospective ECG-gated versus non-gated 64-row CT angiography of the aorta at the same radiation dose: Comparison of motion artifacts, diagnostic confidence and signal-to-noise-ratios

    International Nuclear Information System (INIS)

    Schernthaner, Ruediger E.; Stadler, Alfred; Beitzke, Dietrich; Homolka, Peter; Weber, Michael; Lammer, Johannes; Czerny, Martin; Loewe, Christian

    2012-01-01

    Purpose: To compare ECG-gated and non-gated CT angiography of the aorta at the same radiation dose, with regard to motion artifacts (MA), diagnostic confidence (DC) and signal-to-noise-ratios (SNRs). Materials and methods: Sixty consecutive patients prospectively randomized into two groups underwent 64-row CT angiography, with or without dose-modulated ECG-gating, of the entire aorta, due to several pathologies of the ascending aorta. MA and DC were both assessed using a four-point scale. SNRs were calculated by dividing the mean enhancement by the standard deviation. The dose-length-product (DLP) of each examination was recorded and the effective dose was estimated. Results: Dose-modulated ECG-gating showed statistically significant advantages over non-gated CT angiography, with regard to MA (p < 0.001) and DC (p < 0.001), at the aortic valve, at the origin of the coronary arteries, and at the dissection membrane, with a significant correlation (p < 0.001) between MA and DC. At the aortic wall, however, ECG-gated CT angiography showed statistically significant fewer MA (p < 0.001), but not a statistically significant higher DC (p = 0.137) compared to non-gated CT angiography. At the supra-aortic vessels and the descending aorta, the ECG-triggering showed no statistically significant differences with regard to MA (p = 0.861 and 0.526, respectively) and DC (p = 1.88 and 0.728, respectively). The effective dose of ECG-gated CT angiography (23.24 mSv; range, 18.43–25.94 mSv) did not differ significantly (p = 0.051) from that of non-gated CT angiography (24.28 mSv; range, 19.37–29.27 mSv). Conclusion: ECG-gated CT angiography of the entire aorta reduces MA and results in a higher DC with the same SNR, compared to non-gated CT angiography at the same radiation dose.

  6. Low-dose celiac CT angiography with fixed current-time product

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Li Xiaolin; Zhu Shiqiang; Zhang Jiaming; Wang Xiangming; Zou Xiaofeng

    2009-01-01

    Objective: To characterize the feasibility of low-dose CT angiography on 16-slice multi-slice computed tomography (16-MSCT), and its relationship to the noise in the pre-contrast image and enhancement value. Methods: Forty-three consecutive patients (male 21, female 22, mean age 59 years, median age 56 years) underwent abdominal 16-MSCT (Toshiba Aquilion 16) with constant scanning parameters including 120 kVp, a 0.5-second gantry rotation time, a pitch of 0.938: 1, and 16 x 1-mm detector collimation. The mA was set at 200 in the pre-contrast scan and 160 in the contrast-enhanced scan. The arterial phase images were retrospectively reconstructed with 1-mm slice thickness, 0.8 mm interval. The pre-contrast noise was defined as the standard deviation (SD) of the aorta at the level of right posterior crura of diaphragm. The enhancement of aorta was also measured at level of celiac artery. The volume rendering of CT angiography was made and classified into three grades (excellent, good, bad). Receiver operating characteristic curve (ROC) was used to evaluate the relationship between the image quality of CT angiography and noise in the pre-contrast image and enhancement value. Results: Twenty-five cases had the aorta enhancement between 300.0-400.0 HU. The sensitivity and specificity of excellent CTA image was 75% and 62%, respectively when the SD was 12.00. Eighteen cases had the aorta enhancement more than 400.0 HU. The sensitivity and specificity of excellent CTA image was all 100% when the SD was 12.25, and 100% and 75%, respectively when the SD was 13.35. The area under curve of CTA image quality and enhancement in receiver-operated characteristic analysis was 0.907. The enhancement was more than 356.7 HU when the sensitivity and specificity of excellent CTA image was 100% and 60%, respectively, and 389.8 HU when 78% and 80%. When the enhancement was more than 442.4 HU, the specificity of excellent CTA image was 100%. Conclusions: MSCT angiography with low radiation

  7. Spiral CT angiography of middle cerebral artery stenoses

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Neff, K.W.; Ries, S.; Sommer, A.; Steinke, W.; Georgi, M.

    1996-01-01

    Transcranial Doppler ultrasonography (TCD) and magnetic resonance angiography (MRA) are well-established techniques for ascertaining intracranial obstructive artery disease. The short examination time required for additional helical CT angiography (CTA) allows quick management of emergency patients already undergoing native CT. However, today the ability of CTA to detect stenoses of the middle cerebral artery (MCA) has not been proven. To analyse the value of CTA in the classification of atherosclerotic disease 23 MCA stenoses confirmed by TCD and MRA were investigated. CTA was performed on a Hispeed advantage scanner (GE) using a bolus injection of 70 ml KM and 40 ml NaCl with a flow rate of 2.5 ml/s, a thickness of 1 mm, a pitch of 1.5 and a 1 mm increment. CTA was presented as maximum intensity projection (MIP) and as multi-projection volume reconstruction (MPVR). A three-step classification of stenosis was compared with the results of TCD and MRA. Good opacification of the MCA was achieved in M1 and M2 segments in all patients. Classification of stenosis by CTA agreed with MRA and TCD in 14 cases; 7 stenoses were assigned to a lower classification by CTA. Two lowgrade stenoses could not be proven by CTA. Although MIP and MPVR yield the same result in stenosis classification MPVR showed a sharper image quality. In contrast to MRA, veins were highly opacified in CTA. Artery and vein were sometimes superimposed, which had to be avoided by changing the projection angle. Medium- and high-grade MCA stenoses can be demonstrated by CTA quickly and reliably. Compared to MRA and TCD, CTA provides lower grading of stenosis. (orig.) [de

  8. Prospective versus retrospective ECG-gated multislice CT coronary angiography: A systematic review of radiation dose and diagnostic accuracy

    International Nuclear Information System (INIS)

    Sun Zhonghua; Ng, Kwan-Hoong

    2012-01-01

    Purpose: To perform a systematic review of the radiation dose and diagnostic accuracy of prospective versus retrospective ECG-gated multislice CT coronary angiography. Materials and methods: A search of Pubmed/Medline and Sciencedirect databases for English literature was performed to identify studies comparing prospective and retrospective ECG-gated multislice CT angiography in the diagnosis of coronary artery disease. Effective dose, dose length product, image quality and diagnostic value were compared between two groups of studies. Results: 22 studies were included for analysis. The mean effective dose of prospective ECG-gated scans was 4.5 mSv (95% CI: 3.6, 5.3 mSv), which is significantly lower than that of retrospective scans, which is 13.8 mSv (95% CI: 11.5, 16.0 mSv) (p < 0.001). The mean dose length product was 225 mGy cm (95% CI: 188, 262 mGy cm) and 822 mGy cm (95% CI: 630, 1013 mGy cm) for the prospective and retrospective ECG-gated scans, respectively, indicating a statistically significant difference between these two protocols (p < 0.0001). The mean sensitivity and specificity of multislice CT angiography in the diagnosis of coronary artery disease was 97.7% (95% CI: 93.7%, 100%) and 92.1% (95% CI: 87.2%, 97%) for prospective ECG-gated scans; 95.2% (95% CI: 91%, 99.5%) and 94.4% (95% CI: 88.5%, 100%) for retrospective ECG-gated scans, respectively, with no significant difference for sensitivity but significant difference for specificity (p = 0.047). Conclusion: Multislice CT coronary angiography with prospective ECG-gating leads to a significant reduction of radiation dose when compared to that of retrospective ECG-gating, while offering comparable image quality and diagnostic value.

  9. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    International Nuclear Information System (INIS)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha

    2016-01-01

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  10. Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Cantador, Alex Aparecido; Siqueira, Daniel Emilio Dalledone; Jacobsen, Octavio Barcellos; Baracat, Jamal; Pereira, Ines Minniti Rodrigues; Menezes, Fabio Hüsemann; Guillaumon, Ana Terezinha, E-mail: alex_cantador@yahoo.com.br [Universidade Estadual de Campinas (FCM/UNICAMP), Campinas, SP (Brazil). Faculdade de Ciencias Medicas

    2016-07-15

    Objective: To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. Materials and Methods: This was a prospective study involving 30 patients who had undergone endovascular repair of infrarenal aortoiliac aneurysms. Duplex ultrasound and CT angiography were performed simultaneously by independent radiologists. Measurements of the aneurysm sac diameter were assessed, and the presence or absence of endoleaks was determined. Results: The average diameter of the aneurysm sac, as determined by duplex ultrasound and CT angiography was 6.09 ± 1.95 and 6.27 ± 2.16 cm, respectively. Pearson's correlation coefficient showing a statistically significant correlation (R = 0.88; p < 0.01). Comparing the duplex ultrasound and CT angiography results regarding the detection of endoleaks, we found that the former had a negative predictive value of 92.59% and a specificity of 96.15%. Conclusion: Our results show that there is little variation between the two methods evaluated, and that the choice between the two would have no significant effect on clinical management. Duplex ultrasound could replace CT angiography in the postoperative follow-up of endovascular aneurysm repair of the infrarenal aorta, because it is a low-cost procedure without the potential clinical complications related to the use of iodinated contrast and exposure to radiation. (author)

  11. Liver hydatid cyst ruptured into the thorax: CT angiography findings of a case

    International Nuclear Information System (INIS)

    Kara, K.; Ors, F.; Bozlar, U.; Tasar, M.

    2012-01-01

    Full text: Introduction: Intrathoracic rupture of hepatic hydatid cyst is a rare but severe condition causing a spectrum of lesions to the pleura, lung parenchyma, and bronchi. Pulmonary complications result from the proximity of hydatid cysts in the liver and the diaphragm. Objectives and tasks: In this report we aimed to present computed tomography (CT) angiography findings of a case with liver hydatid cyst ruptured into the thorax. The patient underwent CT angiography examination with suspicion of pulmonary embolism. Materials and methods: A 71-year-old female patient admitted to our emergency department with complaints of severe and persistent cough. Basal region of the right hemithorax could not get breath sounds on physical examination. Chest radiography revealed the presence of consolidation-effusion. The patient was treated with antibiotherapy for pneumonia and parapneumonic effusion. Because of the clinical symptoms and chest radiograph findings persisted the patient underwent CT angiography examination with suspicion of pulmonary embolism. Results: On CT angiography images pulmonary artery and its branches were normal. There were subtotal collapse in the right middle and lower lung lobes and complicated cystic lesion that has air densities in the basal interlobar space. Another thick walled complicated cystic lesion with multiple septations and air densities was detected in the right posterior liver lobe. The right hemidiaphragm was interrupted and the right liver lobe partially herniated into the thorax cavity. Serologic tests were positive for Echinococcus granulosus and there were prior therapy history for liver cyst hydatid. The diagnostic aspiration findings were consistent with hydatid cyst lesion. Conclusion: In patients with hepatic hydatid cyst associated with persistent and severe cough, thoracic rupture of the cyst should be considered in differential diagnosis. CT angiography is fast, non-invasive and effective method in the detection of

  12. Renal computed angiography. Part I: Renal CT arteriography in hypertension

    International Nuclear Information System (INIS)

    Al-Amin, M.; Hadjidekov, V.

    2012-01-01

    Visualization of renal vasculature is needed in several clinical condition among which hypertension is dominant. CT angiography now day replaces catheter angiography as non-invasive method. The goal of this study is to present initial authors experience in visualization of renal arteries using 64 MDCT and to evaluated the utility in hypertensive patients. MDCT assures excellent assessment of renal arteries conditions. Multiplanar reconstruction and allow better delineation in tortuous vessels course and anatomic variants. (authors)

  13. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose

    International Nuclear Information System (INIS)

    Arnoldi, E.; Ramos-Duran, L.; Abro, J.A.; Costello, P.; Zwerner, P.L.; Schoepf, U.J.; Nikolaou, K.; Reiser, M.F.

    2010-01-01

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses (≥50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6±1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [de

  14. Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography

    International Nuclear Information System (INIS)

    Young, N.; Kingston, R.J.; Markson, G.; Dorsch, N.W.C.; McMahon, J.

    2001-01-01

    The goal of this study was to assess the usefulness of spiral CT angiography (CTA) with three- dimensional reconstructions in defining intracranial aneurysms, particularly around the Circle of Willis. Two hundred consecutive patients with angiographic and/or surgical correlation were studied between 1993 and 1998, with CTA performed on a GE HiSpeed unit and Windows workstation. The following clinical situations were evaluated: conventional CT suspicion of an aneurysm; follow-up of treated aneurysm remnants or of untreated aneurysms; subarachnoid haemorrhage (SAH) and negative angiography; family or past aneurysm history; and for improved definition of aneurysm anatomy. Spiral CTA detected 140 of 144 aneurysms, and an overall sensitivity of 97%, including 30 of 32 aneurysms 3 mm or less in size. In 38 patients with SAH and negative angiography, CTA found six of the seven aneurysms finally diagnosed. There was no significant artefact in 17 of 23 patients (74%) with clips. The specificity of CTA was 86% with 8 false-positive cases. Spiral CTA is very useful in demonstrating intracranial aneurysms. (orig.)

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  18. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  19. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  20. 3D-CT angiography with ultrafast CT in the diagnosis of pulmonary thromboembolism

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Hamada, Seiki; Takamiya, Makoto; Imakita, Satoshi; Yamada, Naoaki; Takase, Kei; Iino, Misako; Nakanishi, Norifumi

    1995-01-01

    The usefulness of 3D-CT angiography (3D-CTA) with ultrafast CT (UFCT) in the diagnosis of pulmonary thromboembolism (PTE) was evaluated. UFCT was carried out in 10 patients with PTE (acute: 5 cases, chronic: 5 cases) and one case with pulmonary artery thrombosis secondary to pulmonary hypertension with atrial septal defect. CT scanning was performed with Imatron C-100XL and C-150L. For the imaging, single-slice step volume scan mode was used with scan time of 100 msec and slice thickness of 6 mm. Contiguous axial images were obtained after contrast enhancement with slice interval of 6 mm. 3D-CTA was reconstructed from 2D-CT images with workstation, and was compared with pulmonary angiograms (PAG) or operative findings. The images of 3D-CTA had good quality and they were more useful than 2D-CT images in better understanding of the configuration and the extent of the thrombi. In comparison with PAG, 3D-CTA gave equivalent information in terms of central pulmonary emboli. Moreover, 3D-CTA had advantages over PAG in demonstrating both the blood lumen and the thrombus on the same image with capability of multi-directional displays. 3D-CTA with UFCT is the useful non-invasive imaging modality in the diagnosis of PTE. (author)

  1. CT coronary angiography: examination technique, clinical results, and outlook on future developments

    International Nuclear Information System (INIS)

    Dewey, M.; Hamm, B.

    2007-01-01

    Multislice computed tomography (MSCT) after intravenous contrast agent administration enables visualization of the coronary arteries with high spatial resolution (voxel sizes down to 0.5 x 0.35 x 0.35 mm3) and a short scan time. Magnetic resonance imaging (MRI) is also intensively studied with respect to the noninvasive detection of coronary artery stenosis and thus the detection of coronary artery disease (CAD) without radiation exposure but is not equal to MSCT at present. This article provides an overview of the historical development of CT coronary angiography from 4-slice CT to 16-slice CT and 64-slice CT. A crucial aspect of this development is the improvement in image quality resulting from shorter breath-hold periods and the reduced gantry rotation time. Other techniques that appear to considerably improve image quality and accuracy and make CT independent of patient heart rates are multisegment reconstruction and dual-source CT. Sublingual nitroglycerin as well as oral or intravenous betablocker administration should be considered in relation to the diagnostic question to be answered and the patient's heart rate. In the studies available CT coronary angiography with at least 12 simultaneous detector rows has a sensitivity of 96.9 % and a specificity of 75.3 % at the patient level. Especially the negative predictive value of CT (94.6 %) emphasizes the idea that this technique may reliably exclude CAD in patients with intermediate pretest likelihood. In the near future, 256-slice CT will allow examination of the entire heart during one heartbeat or even 4D CT scanning with simultaneous assessment of myocardial perfusion. Automatic or semiautomatic software tools will assume a central place in detecting and quantifying coronary artery stenoses and plaques as well as in the analysis of cardiac function in the clinical setting over the next years. Prior to its routine clinical use, the cost-effectiveness of CT coronary angiography must be determined and the

  2. Carotid stenosis: a comparison between MR and spiral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Magarelli, N.; Carriero, A.; Bonomo, L. [Institute of Radiology, University ``G. D`Annunzio``, Chieti (Italy); Scarabino, T.; Simeone, A.L.; Florio, F. [IRCCS, Foggia (Italy); Salvolini, U. [Department of Neuroradiology, University of Ancona (Italy)

    1998-06-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.) With 6 figs., 4 tabs., 17 refs.

  3. Carotid stenosis: a comparison between MR and spiral CT angiography

    International Nuclear Information System (INIS)

    Magarelli, N.; Carriero, A.; Bonomo, L.; Scarabino, T.; Simeone, A.L.; Florio, F.; Salvolini, U.

    1998-01-01

    We performed a preliminary study comparing three-dimensional time-of-flight (3 D TOF) magnetic resonance angiography (MRA) and spiral CT angiography (SCTA) in the detection and assessment of internal carotid artery stenosis. Digital subtraction angiography (DSA) was the reference examination. We examined 20 patients with signs of cerebrovascular insufficiency, who underwent MRA, SCTA and DSA within a 3 day period. Both internal carotid arteries were assessed by three blinded readers for degree of stenosis at two different levels (bulb and remaining section) giving a total of 80 assessments. Interobserver variability, sensitivity, specificity, diagnostic accuracy, concordance, overestimation and underestimation were assessed. Interobserver variability was not statistically significant. MRA showed higher sensitivity, specificity, diagnostic accuracy and concordance than SCTA (92.0 % vs 80.8 %, 98.2 % vs 96.4 %, 96.3 % vs 91.3 % and 96.0 % vs 88.0 %, respectively). MRA gave rise to a 5.0 % overestimation rate, whereas SCTA occasioned a 7.5 % underestimation rate. These differences are not statistically significant. These results suggest that MRA is a more useful, noninvasive modality for assessment of the internal carotid artery with a more than 70 % stenosis. (orig.)

  4. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  5. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  6. CT angiography using electron-beam computed tomography (EBCT). A phantom study

    International Nuclear Information System (INIS)

    Uchino, Akira; Kato, Akira; Kudo, Sho

    1997-01-01

    The purpose of this study was to evaluate the accuracy of CT angiography in small vessels using electron-beam computed tomography (EBCT). Vessel phantoms with inner diameters of 8 mm, 6 mm, and 4 mm were prepared with segments of 75%, 50%, and 25% stenosis in each vessel. The vessels were filled with contrast medium (Iopamidol 300 at 1/24 dilution, approximately 380 HU). The EBCT apparatus used was an Imatron C-150. The step volume scan mode was used with slice thicknesses of 1.5 mm and 3.0 mm, scan time of 0.3 sec, and 210 mm field of view. Images with a slice thickness of 1.5 mm were definitely better than those with a slice thickness of 3.0 mm. The quality of maximum intensity projection (MIP) images was quite similar to that of three-dimensional (3D) images. Using the 8 mm vessel phantom, all stenotic segments were accurately visualized on CT angiography. The 50% stenotic segments were accurately estimated in all vessels. However, the 75% stenotic segments were slightly overestimated in smaller vessels, and the 25% stenotic segments were slightly underestimated in smaller vessels. We consider CT angiography using EBCT to be a useful, less invasive diagnostic modality for stenoocclusive lesions. (author)

  7. Comparative study of coronary plaque and stenosis: CT versus MR angiography

    International Nuclear Information System (INIS)

    Liu Xin; Zhao Xihai; Cheng Liuquan; Zhao Shaohong; Cai Zulong; Cai Youquan; Yang Li

    2006-01-01

    Objective: To investigate the effect of coronary plaque composition on the extent of stenosis and compare the accuracies of coronary CTA and MRA in detecting significant stenosis (≥50%) caused by different composition plaques. Methods: Thirty patients with coronary heart disease were examined with coronary CTA, MRA and conventional coronary, angiography (CAG) within two weeks. CTA and MRA were performed with a 16-slice CT scanner and hreathhold 3D FIESTA sequence respectively. The coronary plaques were grouped as non-calcified and calcified plaque on CTA images. The accuracies and agreement of CTA and MRA in detecting significant stenosis were evaluated by two experienced radiologists independently using CAG as reference. Results: Fifty-three plaques were detected on CTA. Twenty-eight were non-calcified and the other 25 were calcified. Twenty-one of 28 non-calcified plaques caused significant stenosis on CAG. The sensitivity and specificity of CTA and MRA in detecting significant stenosis were 85.7%, 85.7% and 47.6%, 71.4%, respectively, CTA showed good agreement with CAG (K=0.65). Six of 25 calcified plaques caused significant stenosis on CAG. The sensitivity and specificity of CTA and MRA in detecting significant stenosis were 83.3%, 31.6% and 83.3%, 73.7%, respectively, MRA showed moderate agreement with CAG (K=0.46). Conclusion: CTA was accurate for detecting non-calcified plaque and stenosis, while MRA had advantage to evaluate lumen with severe calcified plaque. (authors)

  8. Usefulness of the Negative Multidetector CT Angiography in Patients with Suspected Pulmonary Embolism

    International Nuclear Information System (INIS)

    Holguin Holguin, Alfonso Jose; Lombana, Milton; Collazos, Giovanny; Bravo, Hector; Abella Calle, Jose

    2012-01-01

    Objective: The aim of the study is to evaluate alternative findings in pulmonary CT angiography using MDCT reported as negative in patients with suspected pulmonary embolism. Material and method: Cross sectional study with 178 patients. We recognized other findings reported in pulmonary CT angiography using MDCT whose result was negative. Subsequently these findings were classified into six different categories of clinical relevance and their association with clinical scenario was analyzed. Results: from November 2004 to June 2007 we requested 231 pulmonary CT angiography using MDCT in patients with suspected pulmonary embolism. 217 patients were included in the final analysis. Of these, 39 (185) were positive for pulmonary embolism. The 178 remaining negative studies, 8.43% were normal, 53.37% were classified as category A, 20.79% category B, 14.04% category C; category D 1.12% and 2.25% were not interpretable. The most frequent diagnoses were pneumonia, interstitial lung disease and cardiogenic pulmonary edema. It was less likely to find a normal report whether the study was requested in the hospital department in emergency patients (OR = 0.38 95% 0.16 to 0.88, p = 0.0007). No differences were found in other categories or between patients younger or older than 65 years (p = 0.436). Conclusion: Pulmonary CT angiography as first line imaging tool in patients with suspected pulmonary embolism is useful, offering alternative diagnoses in hospitalized and emergency room patients, regardless of their age and clinical findings.

  9. Cone-beam CT angiography of the thorax. An experimental study

    International Nuclear Information System (INIS)

    Yoshida, Katsuya; Shimada, Kazuhiro; Tadokoro, Hiroyuki

    1999-01-01

    The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256 x 256 x 256 voxel volume with a voxel dimension of 0.9 x 0.9 x 0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging. (author)

  10. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schlattmann, Peter [University Hospital of Friedrich-Schiller University Jena, Department of Medical Statistics, Informatics and Documentation, Jena (Germany); Schuetz, Georg M. [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, Marc [Freie Universitaet Berlin, Charite, Medical School, Department of Radiology, Humboldt-Universitaet zu Berlin, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2011-09-15

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with {<=}16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  11. Influence of coronary artery disease prevalence on predictive values of coronary CT angiography: a meta-regression analysis

    International Nuclear Information System (INIS)

    Schlattmann, Peter; Schuetz, Georg M.; Dewey, Marc

    2011-01-01

    To evaluate the impact of coronary artery disease (CAD) prevalence on the predictive values of coronary CT angiography. We performed a meta-regression based on a generalised linear mixed model using the binomial distribution and a logit link to analyse the influence of the prevalence of CAD in published studies on the per-patient negative and positive predictive values of CT in comparison to conventional coronary angiography as the reference standard. A prevalence range in which the negative predictive value was higher than 90%, while at the same time the positive predictive value was higher than 70% was considered appropriate. The summary negative and positive predictive values of coronary CT angiography were 93.7% (95% confidence interval [CI] 92.8-94.5%) and 87.5% (95% CI, 86.5-88.5%), respectively. With 95% confidence, negative and positive predictive values higher than 90% and 70% were available with CT for a CAD prevalence of 18-63%. CT systems with >16 detector rows met these requirements for the positive (P < 0.01) and negative (P < 0.05) predictive values in a significantly broader range than systems with ≤16 detector rows. It is reasonable to perform coronary CT angiography as a rule-out test in patients with a low-to-intermediate likelihood of disease. (orig.)

  12. Variations in the origins of the thyroid arteries on CT angiography.

    Science.gov (United States)

    Esen, Kaan; Ozgur, Anil; Balci, Yuksel; Tok, Sermin; Kara, Engin

    2018-02-01

    To investigate the anatomical variations in the origins of the thyroid arteries on CT angiography images. The presence and the origins of the superior thyroid artery, the inferior thyroid artery, and the thyroidea ima artery were retrospectively evaluated based on carotid CT angiography examinations. The bifurcation level of the common carotid artery with respect to the cervical vertebrae and disc spaces was also determined. A total of 640 patients were included in the study. The right and left superior thyroid arteries arose from the external carotid artery in 413 (64.5%) and 254 (39.7%) patients, from the bifurcation of the common carotid artery in 131 (20.5%) and 148 (23.1%) patients, and from the common carotid artery in 90 (14.1%) and 226 (35.3%) patients, respectively. We could not observe the right and the left superior thyroid arteries in 6 (0.9%) and 12 (1.9%) of the patients, respectively. However, the right and left inferior thyroid arteries were not identified in 14 (2.2%) and 45 (7%) of the patients, respectively. The thyroidea ima artery was detected in 2.3% of the patients. The visualization of thyroid arteries on CT angiography images enables the anatomy of the arterial supply system of the thyroid gland to be explored in a noninvasive manner prior to surgery.

  13. Cerebral angiography with prospective ECG triggering preliminary study of dual-source CT

    International Nuclear Information System (INIS)

    Xue Yuejun; Qian Nong; Shao Yanhui; Pan Changjie; Rong Weiliang; Xu Yiqun

    2012-01-01

    Objective: To study the image quality and radiation dose in dual-source CT cerebral angiography with prospective ECG-triggered sequence mode (step-and-shoot, SAS). Methods: A total of forty-three patients with clinically suspected cerebral vascular disease underwent cerebral CT angiography with prospective ECG-triggering (step-and-shoot, SAS). Data acquisition was at 60% R-R interval of the ECG presentation mode. The post-processing included maximum intensity projection (MIP), multiplanar reformation (MPR) and volume rendering (VR). The CTA image quality, radiation dose and rates of excellent images were evaluated. Results: The CTA image quality score was 4.72 ± 0.50 and 97.7% (42/43) patients had excellent CTA images. The average effective dose of SAS-CTA was (0.22 ± 0.01)mSv, which was lower by 76.31% than that of DE-CTA. Conclusions: Prospective ECG-triggering sequence could be used in cerebral angiography with a significant reduction in radiation dose and diagnostic image quality. (authors)

  14. The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Bo; Gu, Guo-jun; Jiang, Hong; Guo, Yi [Medical School of Tongji University, Department of Medical Imaging, Tongji Hospital, Shanghai (China); Shen, Xing [Traditional Chinese Hospital, Department of Radiology, Kun Shan, Jiangsu Province (China); Li, Bo; Zhang, Wei [Medical School of Jiaotong University, Department of Medical Imaging, Renji Hospital, Shanghai (China)

    2017-11-15

    To validate the value of whole-brain computed tomography perfusion (CTP) and CT angiography (CTA) in the diagnosis of mild cognitive impairment (MCI) and Alzheimer's disease (AD). Whole-brain CTP and four-dimensional CT angiography (4D-CTA) images were acquired in 30 MCI, 35 mild AD patients, 35 moderate AD patients, 30 severe AD patients and 50 normal controls (NC). Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and correlation between CTP and 4D-CTA were analysed. Elevated CBF in the left frontal and temporal cortex was found in MCI compared with the NC group. However, TTP was increased in the left hippocampus in mild AD patients compared with NC. In moderate and severe AD patients, hypoperfusion was found in multiple brain areas compared with NC. Finally, we found that the extent of arterial stenosis was negatively correlated with CBF in partial cerebral cortex and hippocampus, and positively correlated with TTP in these areas of AD and MCI patients. Our findings suggest that whole-brain CTP and 4D-CTA could serve as a diagnostic modality in distinguishing MCI and AD, and predicting conversion from MCI based on TTP of left hippocampus. (orig.)

  15. The value of whole-brain CT perfusion imaging and CT angiography using a 320-slice CT scanner in the diagnosis of MCI and AD patients

    International Nuclear Information System (INIS)

    Zhang, Bo; Gu, Guo-jun; Jiang, Hong; Guo, Yi; Shen, Xing; Li, Bo; Zhang, Wei

    2017-01-01

    To validate the value of whole-brain computed tomography perfusion (CTP) and CT angiography (CTA) in the diagnosis of mild cognitive impairment (MCI) and Alzheimer's disease (AD). Whole-brain CTP and four-dimensional CT angiography (4D-CTA) images were acquired in 30 MCI, 35 mild AD patients, 35 moderate AD patients, 30 severe AD patients and 50 normal controls (NC). Cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), time to peak (TTP), and correlation between CTP and 4D-CTA were analysed. Elevated CBF in the left frontal and temporal cortex was found in MCI compared with the NC group. However, TTP was increased in the left hippocampus in mild AD patients compared with NC. In moderate and severe AD patients, hypoperfusion was found in multiple brain areas compared with NC. Finally, we found that the extent of arterial stenosis was negatively correlated with CBF in partial cerebral cortex and hippocampus, and positively correlated with TTP in these areas of AD and MCI patients. Our findings suggest that whole-brain CTP and 4D-CTA could serve as a diagnostic modality in distinguishing MCI and AD, and predicting conversion from MCI based on TTP of left hippocampus. (orig.)

  16. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Archana [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); St. Christopher' s Hospital for Children, Department of Radiology, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); New York Cardiovascular Institute at Lenox Hill Radiology, New York, NY (United States); Servaes, Sabah; Keller, Marc S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Schwartz, Mathew C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Levine Children' s Hospital, Sanger Heart and Vascular Institute, Charlotte, NC (United States); Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging/Radiology, Orlando, FL (United States)

    2017-03-15

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  17. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    International Nuclear Information System (INIS)

    Malik, Archana; Hellinger, Jeffrey C.; Servaes, Sabah; Keller, Marc S.; Schwartz, Mathew C.; Epelman, Monica

    2017-01-01

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  18. Improved Imaging in Cardiac Patients: echocardiography and CT-coronary angiography

    NARCIS (Netherlands)

    T.W. Galema (Tjebbe)

    2010-01-01

    textabstractDiff erent non-invasive imaging modalities are used for to assess cardiac anatomy and function. Echocardiography and MRI allow assessment of cardiac structures and function of the cardiac chambers and valves as well as perfusion of the left ventricular wall while CT-angiography in

  19. Diagnosis of preoperative staging of bladder cancer by CT and angiography

    International Nuclear Information System (INIS)

    Munechika, Hirotsugu; Saito, Kazuhiko; Tanaka, Osamu; Tomiie, Fumitaka; Aihara, Toshinori

    1982-01-01

    The accuracy of computed tomography (CT) and angiography in defining the extent of local invasion was studied retrospectively in 19 patients with surgically proven carcinoma of the bladder. The overall accuracy of CT and angiographic staging in these cases was 54 percent and 47 percent respectively. The diagnosis of carcinoma of the bladder by CT tended to do overstaging rather than understaging. A tangential view of the tumor-bearing area by the selective internal iliac arteriography allows an accurate estimation of the perivesical tumor extension. The topographic diagnosis should be made by CT prior to the angiographic study. (author)

  20. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    International Nuclear Information System (INIS)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip

    2008-01-01

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE

  1. Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Manghat, N.E.; Hamilton, M.C.K.; Joshi, D.; Lyen, S.M.; Negus, I.S.

    2014-01-01

    The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. (orig.)

  2. Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, J.C.L.; Manghat, N.E.; Hamilton, M.C.K. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); University Hospitals Bristol NHS Foundation Trust, National Institute for Health Research (NIHR) Cardiovascular Biomedical Research Unit, Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Joshi, D.; Lyen, S.M. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Negus, I.S. [University Hospitals Bristol NHS Foundation Trust, Department of Medical Physics and Bioengineering, Bristol Royal Infirmary, Bristol (United Kingdom)

    2014-10-15

    The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. (orig.)

  3. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  4. Preoperative CT angiography reduces surgery time in perforator flap reconstruction

    NARCIS (Netherlands)

    Smit, Jeroen M.; Dimopoulou, Angeliki; Liss, Anders G.; Zeebregts, Clark J.; Kildal, Morten; Whitaker, Iain S.; Magnusson, Anders; Acosta, Rafael

    The use of perforator flaps in breast reconstructions has increased considerably in the past decade. A disadvantage of the perforator flap is difficult dissection, which results in a longer procedure. During spring 2006, we introduced CT angiography (CTA) as part of the diagnostic work-up in

  5. Minimally invasive autopsy employing post-mortem CT and targeted coronary angiography: evaluation of its application to a routine Coronial service.

    Science.gov (United States)

    Roberts, Ian S D; Traill, Zoe C

    2014-01-01

    Post-mortem imaging is a potential alternative to traditional medicolegal autopsy. We investigate the reduction in number of invasive autopsies required by use of post-mortem CT ± coronary angiography. A total of 120 adult deaths referred to the Coroner were investigated by CT, with coronary angiography employed only for the second series of 60 cases, in order to determine the added value of angiography. The confidence of imaging cause of death was classified as definite (no autopsy), probable, possible or unascertained. Invasive autopsy was not required in 38% of cases without coronary angiography and 70% of cases with angiography. Full autopsy, including brain dissection, was required in only 9% of cases. There was complete agreement between autopsy and radiological causes of death in the cases with a 'probable' imaging cause of death, indicating that cases for which imaging provides an accurate cause of death without autopsy were identified correctly. In two patients, CT demonstrated unsuspected fractures, not detected at subsequent autopsy. A two-thirds reduction in the number of invasive coronial autopsies can be achieved by use of post-mortem CT plus coronary angiography. At the same time, use of post-mortem CT may improve accuracy of diagnosis, particularly for traumatic deaths. © 2013 John Wiley & Sons Ltd.

  6. Novel Application of Postmortem CT Angiography for Evaluation of the Intracranial Vascular Anatomy in Cadaver Heads.

    Science.gov (United States)

    van Eijk, Ruben P A; van der Zwan, Albert; Bleys, Ronald L A W; Regli, Luca; Esposito, Giuseppe

    2015-12-01

    Postmortem CT angiography is a common procedure used to visualize the entire human vasculature. For visualization of a specific organ's vascular anatomy, casting is the preferred method. Because of the permanent and damaging nature of casting, the organ cannot be further used as an experimental model after angiography. Therefore, there is a need for a minimally traumatic method to visualize organ-specific vascular anatomy. The purpose of this study was to develop and evaluate a contrast enhancement technique that is capable of visualizing the intracranial vascular anatomy while preserving the anatomic integrity in cadaver heads. Seven human heads were used in this study. Heads were prepared by cannulating the vertebral and internal carotid arteries. Contrast agent was injected as a mixture of tap water, polyethylene glycol 600, and an iodinated contrast agent. Postmortem imaging was executed on a 64-MDCT scanner. Primary image review and 3D reconstruction were performed on a CT workstation. Clear visualization of the major cerebral arteries and smaller intracranial branches was achieved. Adequate visualization was obtained for both the anterior and posterior intracranial circulation. The minimally traumatic angiography method preserved the vascular integrity of the cadaver heads. A novel application of postmortem CT angiography is presented here. The technique can be used for radiologic evaluation of the intracranial circulation in cadaver heads. After CT angiography, the specimen can be used for further experimental or laboratory testing and teaching purposes.

  7. The role of CT and cerebral angiography in the neurosurgical treatment of cerebrovascular diseases and their sequels

    International Nuclear Information System (INIS)

    Bock, W.J.

    1979-01-01

    It is found that for cerebro-vascular diseases which can be surgically treated, neither angiography nor CT alone yields sufficient information. Only a combination of the two methods can help to reach a clear decision; CT is better suited for course control while angiography helps to make a diagnosis and to decide upon the best surgical treatment. (orig./AJ) [de

  8. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  9. Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Julie M.; Vavere, Andrea L.; Arbab-Zadeh, Armin; Bush, David E.; Lardo, Albert C.; Texter, John; Brinker, Jeffery; Lima, Joao A.C. [Johns Hopkins Hospital, Johns Hopkins University, Department of Medicine, Division of Cardiology, Baltimore, MD (United States); Dewey, Marc [Charite - Universitaetsmedizin Berlin, Medical School, Humboldt-Universitaet und Freie Universitaet zu Berlin, Department of Radiology, Berlin, PO Box 10098 (Germany); Rochitte, Carlos E.; Lemos, Pedro A. [University of Sao Paulo Medical School, Heart Institute (InCor), Sao Paulo (Brazil); Niinuma, Hiroyuki [Iwate Medical University, Department of Cardiology, Morioka (Japan); Paul, Narinder [Toronto General Hospital, Department of Medical Imaging, Toronto (Canada); Hoe, John [Medi-Rad Associates Ltd, CT Centre, Mt Elizabeth Hospital, Singapore (Singapore); Roos, Albert de [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Yoshioka, Kunihiro [Iwate Medical University, Department of Radiology, Morioka (Japan); Cox, Christopher [Johns Hopkins Bloomberg School of Public Health, Department of Epidemiology, Baltimore, MD (United States); Clouse, Melvin E. [Harvard University, Department of Radiology, Beth Israel Deaconess, Boston, MA (United States)

    2009-04-15

    Multislice computed tomography (MSCT) for the noninvasive detection of coronary artery stenoses is a promising candidate for widespread clinical application because of its non-invasive nature and high sensitivity and negative predictive value as found in several previous studies using 16 to 64 simultaneous detector rows. A multi-centre study of CT coronary angiography using 16 simultaneous detector rows has shown that 16-slice CT is limited by a high number of nondiagnostic cases and a high false-positive rate. A recent meta-analysis indicated a significant interaction between the size of the study sample and the diagnostic odds ratios suggestive of small study bias, highlighting the importance of evaluating MSCT using 64 simultaneous detector rows in a multi-centre approach with a larger sample size. In this manuscript we detail the objectives and methods of the prospective ''CORE-64'' trial (''Coronary Evaluation Using Multidetector Spiral Computed Tomography Angiography using 64 Detectors''). This multi-centre trial was unique in that it assessed the diagnostic performance of 64-slice CT coronary angiography in nine centres worldwide in comparison to conventional coronary angiography. In conclusion, the multi-centre, multi-institutional and multi-continental trial CORE-64 has great potential to ultimately assess the per-patient diagnostic performance of coronary CT angiography using 64 simultaneous detector rows. (orig.)

  10. Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography

    International Nuclear Information System (INIS)

    Wang Min; Qi Hengtao; Wang Ximing; Wang Tao; Chen, Jiu-Hong; Liu Cheng

    2009-01-01

    Objective: To evaluate dose performance and image quality of 64-slice dual source CT (DSCT) in comparison to 64-slice single source CT (SSCT) in cardiac CT angiography (CTA). Methods: 100 patients examined by DSCT and 60 patients scanned by SSCT were included in this study. Objective indices such as image noise, contrast-to-noise ratio and signal-to-noise ratio were analyzed. Subjective image quality was assessed by two cardiovascular radiologists in consensus using a four-point scale (1 = excellent to 4 = not acceptable). Estimation of effective dose was performed on the basis of dose length product (DLP). Results: At low heart rates ( 0.05), but, at high heart rates (>70 bpm), DSCT provided robust image quality (P 70 bpm), DSCT is able to provide robust diagnostic image quality at doses far below that of SSCT.

  11. Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: Observations in an ex vivo model

    NARCIS (Netherlands)

    L. la Grutta (Ludovico); M. Galia (Massimo); G. Gentile; G. Lo Re (G.); E. Grassedonio (Emanuele); F. Coppolino; E. Maffei (Erica); E. Maresi (E.); A. Lo Casto (A.); F. Cademartiri (Filippo); M. Midiri (Massimo)

    2013-01-01

    textabstractObjective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT

  12. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  13. Coronary Vasospastic Angina: Assessment by Multidetector CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Koung Mi; Choi, Sang Il; Chun, Eun Ju; Kim, Jeong A; Youn, Tae Jin; Choi, Dong Ju [Seoul National University Bundang Hospital, Sungnam (Korea, Republic of)

    2012-01-15

    We aimed to describe the imaging findings of multidetector CT coronary angiography (MDCTA) in cases of vasospastic angina (VA) and to determine the accuracy of MDCTA in the identification of VA as compared with invasive coronary angiography with an ergonovine provocation test (CAG with an EG test). Fifty-three patients with clinically suspected VA were enrolled in this study. Two radiologists analyzed the stenosis degree, presence or absence of plaque, plaque composition, and a remodeling index of the related-segment in CAG with an EG test, which were used as a gold standard. We evaluated the diagnostic performances of MDCTA by comparing the MDCTA findings with those of CAG with an EG test. Among the 25 patients with positive CAG with an EG test, all 12 patients with significant stenosis showed no definite plaque with the negative arterial remodeling. Of the six patients with insignificant stenosis, three (50%) had non-calcified plaque (NCP), two (33%) had mixed plaque, and one (17%) had calcified plaque. When the criteria for significant stenosis with negative remodeling but no definite evidence of plaque as a characteristic finding of MDCTA were used, results showed sensitivities, specificities, positive predictive values (PPV), and negative predictive values (NPV) of 48%, 100%, 100%, and 68%, respectively. Significant stenosis with negative remodeling, but no definite evidence of plaque, is the characteristic finding on MDCTA of VA. Cardiac MDCTA shows good diagnostic performance with high specificity and PPV as compared with CAG with an EG test.

  14. Clinical application of three-dimensional spiral CT cerebral angiography with volume rendering

    International Nuclear Information System (INIS)

    Duan Shaoyin; Huang Xi'en; Kang Jianghe; Zhang Dantong; Lin Qingchi; Cai Guoxiang; Xu Meixin; Pang Ruilin

    2002-01-01

    Objective: To study the methodology and assess the clinical value of three-dimensional CT angiography (3D-CTA) with volume rendering (VR) in cerebral vessels. Methods: Sixty-two patients were examined by means of 3D-CTA with volume rendering. VR was used in the reconstruction of 3D images, and the demonstration of normal vessels and vascular lesions were particularly analyzed. At the same time, comparisons were made between the images of VR and SSD, MIP, and also between the diagnosis of VR-CTA and DSA or postoperative results. Results: In VR images, cerebral vessel routes and vessel cavities were showed clearly, while the relationship among vascular lesions, surrounding vessels, and neighboring structure was distinguished. 50 cases (80.6%) were found positive, 48 of which were correct and 2 were false-positive compared with DSA or postoperative results. The accurate rate of diagnosis was 96.0%. There was no obvious difference in showing the cerebral vessel among the images of VR, SSD and MIP (P > 0.25). Conclusion: Three-dimensional CT cerebral angiography with VR is a new noninvasive effective method. It can even partly replace the DSA. The 3D-images have the characteristics of showing the cerebral vascular cavity and overlapped vessels without cutting the skull

  15. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  16. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

    International Nuclear Information System (INIS)

    Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon

    2009-01-01

    Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.

  17. Clinical utility of coronary CT angiography with low-dose chest CT in the evaluation of patients with atypical chest pain: a preliminary report

    International Nuclear Information System (INIS)

    Lim, Soo Jin; Choo, Ki Seok; Kim, Chang Won

    2008-01-01

    To determine the clinical utility of coronary CT angiography (CCTA) with low-dose chest CT in the evaluation of patients with atypical chest pain. Ninety-six patients (mean age 60.2 years; age range, 41-68 years; 70 males) were referred for CCTA with low-dose chest CT (16-slice MDCT, Siemens) for an evaluation of atypical chest pain. When significant stenoses (lumen diameter reduction > 50%) were detected on CCTA, invasive coronary angiography (CA) was performed as the standard of reference. In all patients, medical chart review or telephone contact with patients was used to evaluate the contribution of CCTA with low-dose chest CT to the final clinical diagnosis, at least 6 months after performing CCTA. Among 96 patients, seven patients (7%) had significant stenoses as detected on CCTA, whereas two patients (2%) had significant stenoses and five patients had insignificant stenoses or no stenosis, as detected on conventional catheter angiography. In 18 (19%) of the 89 patients without significant stenosis detected on CCTA, this protocol provided additional information that suggested or confirmed an alternate clinical diagnosis. In patients with atypical chest pain, CCTA with low-dose chest CT could help to exclude ischemic heart disease and could provide important ancillary information for the final diagnosis

  18. Interobserver variability in the evaluation of internal carotid artery stenosis by CT angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Meli, Francisco; Sampere, Tulio; Capunay, Carlos; Sanchez, Flavio; Carrascosa, Jorge

    2001-01-01

    Ischemic cerebral vascular events are primarily due to atherosclerotic narrowing of carotid bifurcation. Catheter Angiography (CA) is the best test for determining carotid artery stenosis, but it is invasive and has some risks. The purpose of this study was to evaluate CT Angiography (CTA) as a non-invasive method compared with CA. Different estimate procedures (NASCET, ESCT and area quantification) were done to compare the Sensitivity (S) and Specificity (E) of each one with CA. Afterwards, interobserver variability of the three procedures was evaluated. Thirty-eight internal carotid arteries were studied in 19 patients with transient ischemic attacks. CTA studies were done in a helical CT scanner. The images were evaluated in a workstation by two radiologists, who were blinded to the percentage of stenosis determined by CA. For statistical analysis, the measurement of stenosis percentage was divided in two groups: a) Negative (0-69%) and b) Positive:(70-100%). Kappa analysis (K) was used to determine the agreement of stenosis. Results: Observer 1: Sensitivity (S) NASCET: 94%, ESCT: 77% and area 94% and Specificity (E): 91%, 87,5% and 87,5%. Observer 2: 77%, 77% and 74%. The interobserver K was 0.83, 0792 and 0.78 for NASCET, ESCT and area quantification methods respectively. In conclusion, CTA has high S and E especially in NASCET and area quantification. (author)

  19. Noninvasive evaluation of cerebral arteriovenous malformations by 4D-CT angiography using 320-detector row CT

    International Nuclear Information System (INIS)

    Tajiri, H.; Jin, L.; Tsukiyama, M.; Suzuki, Y.; Sekine, S.; Shimizu, T.; Ohiwa, T.

    2012-01-01

    Full text: Objective: Four-dimensional computed tomography angiography (4D-CTA) is a new and promising technique in the diagnosis of patients with cerebral arteriovenous malformations (AVMs). The purpose of this retrospective study was to investigate the utility of 4D-CTA using whole-brain 320-detector row CT for assessing cerebral AVMs compared with conventional angiography (CA). Materials and methods: Participants included patients admitted to our institution from November 2010 to March 2012 due to cerebral AVMs who underwent both 4D-CTA and CA within 14 days. The diagnosis of AVM was finally confirmed by CA. Two readers reviewed 4D-CTA and CA under consensus regarding AVM detection rate and each component of the AVM (feeders, nidi, drainers) using a four-point grading scale (excellent=3, good=2, fair=1, poor=0), and the Spetzler-Martin (S-M) grade. Results: During the study period, 11 patients met the inclusion criteria. The average score for feeders, nidi, and drainers was 2.0, 2.3, and 2.5 in 4D-CTA and 2.4, 2.6, and 2.7 in CA, respectively. The average S-M grade score was 2.0 in all patients. There were no statistically significant differences between the two modalities (P<.005). Conclusion: 4D-CTA using 320-detector row CT is a very reliable method and offers diagnostic performance equivalent to CA for detecting and predicting S-M classification of cerebral AVMs.

  20. Anomalous origin of coronary artery: the role of multislice CT Angiography: a case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Daniel Rocha; Barros, Marcio Vinicius Lins; Nunes, Maria do Carmo Pereira; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil)

    2012-07-15

    Anomalous origin of coronary arteries is a relatively rare entity and can present different clinical forms. Recently, CT angiography of the coronary arteries have demonstrated an important role in the diagnosis and management of these anomalies. We present the case of a young female without significant comorbidities who presented with cardiopulmonary arrest, being revived by a team of customer service mobile emergency. After completion of multislice CT angiography of the coronary arteries was observed anomalous origin of left main coronary artery in the right coronary artery, no signs of extrinsic compression. Patient received a defibrillator and had an uneventful follow-up performed. Multislice CT angiography is minimally invasive diagnostic methods to detect the origin and trajectory of the coronary arteries, allowing an alternative to cardiac catheterization for evaluation of patients with anomalous origin of coronary arteries. (author)

  1. Multiple detector-row CT angiography of the renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik. E-mail: dominik.fleischmann@univie.ac.at

    2003-03-01

    Computed tomography angiography (CTA) of the abdomen with multiple detector-row computed tomography (MD-CT) is an effective technique for minimally invasive imaging of the renal arteries and the visceral vasculature. This article reviews the clinical and technical aspects of MD-CT angiography in terms of image acquisition and reconstruction parameters, contrast medium application, and three-dimensional visualization with special attention to renal and mesenteric vascular imaging. Because of its high sensitivity to detect renal artery stenosis on the one hand, and because a normal renal CTA virtually excludes the presence of a significant renal artery stenosis on the other hand, renal CTA plays a useful role in the management of patients with suspected renovascular hypertension. Mesenteric CTA is a useful tool for visualizing normal vascular anatomy and its variants--particularly in the setting of organ transplantation. Vascular pathology, e.g. atherosclerotic disease (abdominal angina), or aneurysms of the visceral arteries are reliably assessed with CTA. Mesenteric CTA is an invaluable adjunct to abdominal CT in the setting of abdominal emergencies, because of its ability to detect the causes of acute intestinal ischemia (superior mesenteric artery embolism or thrombosis, superior mesenteric vein thrombosis). Accurate timing of the CTA acquisition and the subsequent parenchymal phase acquisition relative to the contrast medium transit time is critical to obtain excellent image quality in double-pass abdominal CT acquisitions.

  2. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    Energy Technology Data Exchange (ETDEWEB)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Neuroradiology, Tuebingen (Germany); Bongers, Malte Niklas [Eberhard Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-07-15

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  3. Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling - improved image quality by iterative metal artifact reduction

    International Nuclear Information System (INIS)

    Bier, Georg; Hempel, Johann-Martin; Oergel, Anja; Hauser, Till-Karsten; Ernemann, Ulrike; Hennersdorf, Florian; Bongers, Malte Niklas

    2017-01-01

    This paper aims to evaluate a new iterative metal artifact reduction algorithm for post-interventional evaluation of brain tissue and intracranial arteries. The data of 20 patients that underwent follow-up cranial CT and cranial CT angiography after clipping or coiling of an intracranial aneurysm was retrospectively analyzed. After the images were processed using a novel iterative metal artifact reduction algorithm, images with and without metal artifact reduction were qualitatively evaluated by two readers, using a five-point Likert scale. Moreover, artifact strength was quantitatively assessed in terms of CT attenuation and standard deviation alterations. The qualitative analysis yielded a significant increase in image quality (p = 0.0057) in iteratively processed images with substantial inter-observer agreement (k = 0.72), while the CTA image quality did not differ (p = 0.864) and even showed vessel contrast reduction in six cases (30%). The mean relative attenuation difference was 27% without metal artifact reduction vs. 11% for iterative metal artifact reduction images (p = 0.0003). The new iterative metal artifact reduction algorithm enhances non-enhanced CT image quality after clipping or coiling, but in CT-angiography images, the contrast of adjacent vessels can be compromised. (orig.)

  4. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  5. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT.

    Science.gov (United States)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kaetsu, Yasuhiro; Kitao, Shinichiro; Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro; Ogawa, Toshihide

    2017-07-01

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. • Computed tomography angiography tends to overestimate stenosis in calcified coronary artery. • Dual-energy CT enables us to suppress calcification of coronary artery lesions. • Calcification-suppressed material density imaging reduces false-positive diagnosis of calcified lesion.

  6. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  7. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose

  8. CT-angiography source images indicate less fatal outcome despite coma of patients in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Pallesen, Lars P; Khomenko, Andrei; Dzialowski, Imanuel; Barlinn, Jessica; Barlinn, Kristian; Zerna, Charlotte; van der Hoeven, Erik Jrj; Algra, Ale; Kapelle, L Jaap; Michel, Patrik; Bodechtel, Ulf; Demchuk, Andrew M; Schonewille, Wouter; Puetz, Volker

    2017-02-01

    Background Coma is associated with poor outcome in patients with basilar artery occlusion. Aims We sought to assess whether the posterior circulation Acute Stroke Prognosis Early CT Score and the Pons-Midbrain Index applied to CT angiography source images predict the outcome of comatose patients in the Basilar Artery International Cooperation Study. Methods Basilar Artery International Cooperation Study was a prospective, observational registry of patients with acute basilar artery occlusion with 48 recruiting centers worldwide. We applied posterior circulation Acute Stroke Prognosis Early CT Score and Pons-Midbrain Index to CT angiography source images of Basilar Artery International Cooperation Study patients who presented with coma. We calculated adjusted risk ratios to assess the association of dichotomized posterior circulation Acute Stroke Prognosis Early CT Score (≥8 vs. International Cooperation Study registry, CT angiography source images were available for review in 158 patients. Among these, 78 patients (49%) presented with coma. Compared to non-comatose patients, comatose patients were more likely to die (risk ratios 2.34; CI 95% 1.56-3.52) and less likely to have a favourable outcome (risk ratios 0.44; CI 95% 0.24-0.80). Among comatose patients, a Pons-Midbrain Index < 3 was related to reduced mortality (adjusted RR 0.66; 95% CI 0.46-0.96), but not to favourable outcome (adjusted RR 1.19; 95% CI 0.39-3.62). Posterior circulation Acute Stroke Prognosis Early CT Score dichotomized at ≥ 8 vs. <8 was not significantly associated with death (adjusted RR 0.70; 95% CI 0.46-1.05). Conclusion In comatose patients with basilar artery occlusion, the extent of brainstem ischemia appears to be related to mortality but not to favourable outcome.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  10. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Sakamoto, Ichiro [Kyushu University, Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Fukuoka (Japan); Yamamura, Kenichiro [Kyushu University, Department of Pediatrics, Graduate School of Medical Sciences, Fukuoka (Japan); Yabuuchi, Hidetake [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-02-15

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. (orig.)

  11. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography

    International Nuclear Information System (INIS)

    Yamasaki, Yuzo; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Honda, Hiroshi; Nagao, Michinobu; Kawanami, Satoshi; Sakamoto, Ichiro; Yamamura, Kenichiro; Yabuuchi, Hidetake

    2017-01-01

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. (orig.)

  12. A study of whole brain perfusion CT and CT angiography in hyperacute and acute cerebral infarction

    International Nuclear Information System (INIS)

    Zhang Yonghai; Bai Junhu; Zhang Ming; Yang Guocai; Tang Guibo; Fang Jun; Shi Wei; Li Xinghua; Liu Suping; Lu Qing; Tang Jun

    2005-01-01

    Objective: To evaluate the diagnostic value of whole-brain perfusion blood volume-weighted CT imaging (PWCT) and simultaneous CT angiography (CTA) on early stage of cerebral ischemic infarction. Methods: Non-contrast CT (NCCT), CT perfusion-weighted imaging (PWCT) and delayed CT (DCT) were conducted on 20 cases of early ischemic infarction of whose onset time ranged from 2 to 24 hours. All cases were reexamined with CT or MRI one week to one month later. CT values and perfusion blood volume (PBV) of central and peripheral low perfusion areas as well as those of collateral side were measured. CTA was reconstructed with PWCT as source images to evaluate occlusion or stenosis of blood vessel, and DCT was used to detect the collateral circulation. Results: Of the 20 cases, NCCT, PWCT and CTA were negative in 10 cases in which 6 were confirmed as Transient Ischemic Attack (TIA) on reexamined CT and clinical features, and the other 4 were confirmed as lacunar infarction. For the remaining 10 cases, a comparison was made with ANOVA between low perfusion area (central, peripheral inside and outside) and collateral side. The difference was significant (P<0.01). However, no significant difference was revealed in the central, peripheral inside and outside areas. PBV values were significant in low perfusion area and collateral side (P<0.05). The area of the final infarction was larger than that of the low perfusion area, and the percentage of enlargement exhibited medium negative correlation to the time of ischemia. CTA indicated that 2 cases suffered from left middle cerebral artery occlusion, meanwhile anterior and middle branches of MCA in the other 3 cases were not identified. The sensitivity of NCCT, PWCT and CTA were 28.5%, 71.4% and 35.7% respectively. DCT indicated that 5 cases had asymmetrical blood vessels. Conclusion: The whole-brain perfusion-weighted CT imaging and simultaneous CT angiography (CTA) is p roved to be a simple, timesaving and effective method for the

  13. Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography

    International Nuclear Information System (INIS)

    Meier, A.; Wurnig, M.; Desbiolles, L.; Leschka, S.; Frauenfelder, T.; Alkadhi, H.

    2015-01-01

    Aim: To investigate the value of advanced virtual monoenergetic image reconstruction (mono-plus) from dual-energy computed tomography (CT) for improving the contrast of CT pulmonary angiography (CTPA). Materials and methods: Forty consecutive patients (25 women, mean 62.5 years, range 28–87 years) underwent 192-section dual-source CTPA with dual-energy CT (90/150 SnkVp) after the administration of 60 ml contrast media (300 mg iodine/ml). Conventional virtual monochromatic images at 60 keV and 17 mono-plus image datasets from 40–190 keV (in 10 keV steps) were reconstructed. Subjective image quality (artefacts, subjective noise) was rated. Attenuation was measured in the pulmonary trunk and in the right lower lobe pulmonary artery; noise was measured in the periscapular musculature. The signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated for each patient and dataset. Comparisons between monochromatic images and mono-plus images were performed by repeated measures analysis of variance (ANOVA) with post-hoc Bonferroni correction. Results: Interreader agreement was good to excellent for subjective image quality (ICC: 0.616–0.889). As compared to conventional 60 keV images, artefacts occurred less (p=0.001) and subjective noise was rated lower (p<0.001) in mono-plus 40 keV images. Noise was lower (p<0.001), and the SNR and CNR in the pulmonary trunk and right lower lobe pulmonary artery were higher (both, p<0.001) in mono-plus 40 keV images compared to conventional monoenergetic 60 keV images. Transient interruption of contrast (TIC) was found in 14/40 (35%) of patients, with subjective contrast being similar 8/40 (20%) or higher 32/40 (80%) in mono-plus 40 keV as compared to conventional monoenergetic 60 keV images. Conclusions: Compared to conventional virtual monoenergetic imaging, mono-plus images at 40 keV improve the contrast of dual-energy CTPA. - Highlights: • Advanced monoenergetic image reconstruction from dual-energy CT

  14. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  15. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    International Nuclear Information System (INIS)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu; Bullier, Eric; Riviere, Annalisa; Dromer, Claire; Picard, Francois; Billes, Marc-Alain; Corneloup, Olivier

    2014-01-01

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  16. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [German] Die periphere arterielle Verschlusskrankheit (PAVK) ist eine wesentliche Komplikation des Diabetes mellitus und stellt aufgrund ausgepraegter Gefaessverkalkungen eine diagnostische

  17. Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

    Science.gov (United States)

    Kingston, Mitchell J; Perriman, Diana M; Neeman, Teresa; Smith, Paul N; Webb, Alexandra L

    2016-07-01

    Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Extent of hypoattenuation on CT angiography source images in basilar artery occlusion: prognostic value in the Basilar Artery International Cooperation Study.

    Science.gov (United States)

    Puetz, Volker; Khomenko, Andrei; Hill, Michael D; Dzialowski, Imanuel; Michel, Patrik; Weimar, Christian; Wijman, Christine A C; Mattle, Heinrich P; Engelter, Stefan T; Muir, Keith W; Pfefferkorn, Thomas; Tanne, David; Szabo, Kristina; Kappelle, L Jaap; Algra, Ale; von Kummer, Ruediger; Demchuk, Andrew M; Schonewille, Wouter J

    2011-12-01

    The posterior circulation Acute Stroke Prognosis Early CT Score (pc-ASPECTS) quantifies the extent of early ischemic changes in the posterior circulation with a 10-point grading system. We hypothesized that pc-ASPECTS applied to CT angiography source images predicts functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). BASICS was a prospective, observational registry of consecutive patients with acute symptomatic basilar artery occlusion. Functional outcome was assessed at 1 month. We applied pc-ASPECTS to CT angiography source images of patients with CT angiography for confirmation of basilar artery occlusion. We calculated unadjusted and adjusted risk ratios (RRs) of pc-ASPECTS dichotomized at ≥8 versus <8. Primary outcome measure was favorable outcome (modified Rankin Scale scores 0-3). Secondary outcome measures were mortality and functional independence (modified Rankin Scale scores 0-2). Of 158 patients included, 78 patients had a CT angiography source images pc-ASPECTS≥8. Patients with a pc-ASPECTS≥8 more often had a favorable outcome than patients with a pc-ASPECTS<8 (crude RR, 1.7; 95% CI, 0.98-3.0). After adjustment for age, baseline National Institutes of Health Stroke Scale score, and thrombolysis, pc-ASPECTS≥8 was not related to favorable outcome (RR, 1.3; 95% CI, 0.8-2.2), but it was related to reduced mortality (RR, 0.7; 95% CI, 0.5-0.98) and functional independence (RR, 2.0; 95% CI, 1.1-3.8). In post hoc analysis, pc-ASPECTS dichotomized at ≥6 versus <6 predicted a favorable outcome (adjusted RR, 3.1; 95% CI, 1.2-7.5). pc-ASPECTS on CT angiography source images independently predicted death and functional independence at 1 month in the CT angiography subgroup of patients in the BASICS registry.

  19. Detection of coronary calcification in ultrafast CT compared to coronary angiography

    International Nuclear Information System (INIS)

    Koesling, S.; Hoffmann, U.; Rother, T.; Lieberenz, S.; Heywang-Koebrunner, S.H.; Schulz, H.G.

    1994-01-01

    The angiographical findings of 24 patients with coronary artery disease were compared with qualitative and quantitative detection of coronary calcification by ultrafast CT. Doubts concerning the capabilities of the ultrafast CT for a screening of coronary artery disease arise when the results of one third false positive and fase negative findings are considered. Variations in the quantification of coronary calcification were too great to allow a realistic assessment of the degree of stenosis of the coronary arteries. (orig.) [de

  20. Determining the proportion of coronary segments assessable on 16-slice CT coronary angiography: a brief report

    International Nuclear Information System (INIS)

    Soon, K. H.; Cox, N.; Eccleston, D.; Lim, Y.; Chaitowitz, I.; Bell, K. W.; Kelly, A-M.

    2007-01-01

    Computed tomography coronary angiography (CT-CA) is becoming a popular non-invasive coronary imaging method. We aimed to determine the proportion of coronary segments assessable on a 16-slice CT in comparison with conventional selective coronary angiography (SCA). We identified all patients who had both 16-slice CT-CA and recent SCA (less than 12 months) from March 2004 to July 2005. Two CT reporters blinded to SCA independently classified coronary segment assessability on CT-CA. A cardiologist blinded to CT findings classified assess-ability of coronary segments on SCA. Data were analysed using descriptive statistics and proportion of agreement. Ninety-five study pairs were included in the analysis. Of those, 1161 coronary segments were deemed assessable on SCA and 1103 segments (95%) were also assessable on CT-CA. Nonassessable segments on CT-CA were predominantly in the distal segments and branches of coronary arteries. Reasons for nonassessability were small calibre (48.3%), motion artefacts (20.7%) and poorly reconstructed segments (22.4%). The 16-slice CT was able to assess a high proportion of but not all coronary segments. Nonassessable segments were predominantly distal segments or branches of coronary arteries. Motion artefacts due to heart-rate changes, small calibre and poorly reconstructed images were main causes of nonassessability on 16-slice CT-CA

  1. Comparison of the effect of radiation exposure from dual-energy CT versus single-energy CT on double-strand breaks at CT pulmonary angiography.

    Science.gov (United States)

    Tao, Shu Min; Li, Xie; Schoepf, U Joseph; Nance, John W; Jacobs, Brian E; Zhou, Chang Sheng; Gu, Hai Feng; Lu, Meng Jie; Lu, Guang Ming; Zhang, Long Jiang

    2018-04-01

    To compare the effect of dual-source dual-energy CT versus single-energy CT on DNA double-strand breaks (DSBs) in blood lymphocytes at CT pulmonary angiography (CTPA). Sixty-two patients underwent either dual-energy CTPA (Group 1: n = 21, 80/Sn140 kVp, 89/38 mAs; Group 2: n = 20, 100/Sn140 kVp, 89/76 mAs) or single-energy CTPA (Group 3: n = 21, 120 kVp, 110 mAs). Blood samples were obtained before and 5 min after CTPA. DSBs were assessed with fluorescence microscopy and Kruskal-Walls tests were used to compare DSBs levels among groups. Volume CT dose index (CTDIvol), dose length product (DLP) and organ radiation dose were compared using ANOVA. There were increased excess DSB foci per lymphocyte 5 min after CTPA examinations in three groups (Group 1: P = .001; Group 2: P = .001; Group 3: P = .006). There were no differences among groups regarding excess DSB foci/cell and percentage of excess DSBs (Group 1, 23%; Group 2, 24%; Group 3, 20%; P = .932). CTDIvol, DLP and organ radiation dose in Group 1 were the lowest among the groups (all P dual-source and single-source CTPA, while dual-source dual-energy CT protocols do not increase the estimated radiation dose and also do not result in a higher incidence of DNA DSBs in patients undergoing CTPA. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  3. Preoperative cerebral aneurysm assessment by three-dimensional CT angiography. Feasibility of surgery without cerebral angiography

    International Nuclear Information System (INIS)

    Kashiwagi, Shiro; Yamashita, Katsuhiro; Kato, Shoichi; Ito, Haruhide; Kurokawa, Kensuke; Watanabe, Yutaka

    1999-01-01

    The purpose of this study is to assess the capability of three-dimensional CT angiography (3D-CTA) to replace conventional catheter angiography as a preoperative examination for unruptured intracranial aneurysms. A prospective study was designed to evaluate 18 patients with 20 unruptured intracranial aneurysms (13 middle cerebral artery aneurysms, 6 anterior communicating artery aneurysms, and 1 internal carotid posterior communicating artery aneurysm) who underwent surgery. There were 12 women and 6 men with the average age of 63 years old. All patients were initially diagnosed as having intracranial aneurysms by MR angiography, followed by 3D-CTA and conventional catheter angiography for confirmation. Three experienced neurosurgeons were in charge of the operations. One of the neurosurgeons (surgeon 1) was provided with only 3D-CTA as the preoperative radiological evaluation, while the others (surgeon 2 and 3) were given through assessments with MRA, 3D-CTA, and conventional angiography. Surgeon 1 carried out the operations under careful observation by the surgeons 2 and 3. Problems encountered by the surgeon 1 during surgery were recorded. Neck clipping in 19 aneurysms and dome wrapping in 1 were successfully accomplished. All patients were discharged without complication. Surgeries went smoothly in 16 aneurysms with 3D-CTA alone. Discrepancies between the 3D-CTA findings and microsurgical anatomy were noted in 4 aneurysms: the size of the neck was overestimated in 3 aneurysms, the relationships to parent arteries were obscure in 2 aneurysms, and a perforating artery problematic to neck clipping was missed in 1 aneurysms by 3D-CTA. The results of this study support the notion that 3D-CTA can replace conventional catheter angiography as preoperative examination in the majority of regular-sized anterior circulation aneurysms. Nevertheless, surgeons should recognize and be prepared for the fact that 3D-CTA can give false impression about the aneurysm neck and

  4. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  5. CT Coronary Angiography vs. Coronary Artery Calcium Scoring for the Occupational Assessment of Military Aircrew.

    Science.gov (United States)

    Parsons, Iain; Pavitt, Chris; Chamley, Rebecca; d'Arcy, Jo; Nicol, Ed

    2017-02-01

    To ensure flight safety military aircrew undergo regular clinical and occupational assessment. Coronary artery calcium scoring (CACS) has been established as an imaging modality to noninvasively assess coronary artery disease (CAD). CT coronary angiography (CTCA) potentially offers a more accurate assessment of CAD, but has not been formally assessed in military aircrew. This retrospective cohort study is designed to compare the theoretical differences in downstream investigations and occupational outcomes in aircrew with suspected CAD comparing CTCA with existing CACS pathways. A 2-yr retrospective cohort study of consecutive UK military patients who underwent a CTCA and CACS was undertaken. Patient demographics, CTCA and CACS results, and initial and final occupational restrictions were analyzed comparing current UK, Canadian, and U.S. pathways. There were 44 patients who underwent CACS and CTCA. The commonest indication for a CTCA was a positive exercise ECG. Increasing CACS, stenosis severity, and stenosis burden were associated with significantly greater likelihood of occupational restriction (P = occupational restrictions. Two patients with a calcium score ≤10 had at least 1 single vessel stenosis ≥50%. A CTCA pathway is potentially a better discriminator of CAD burden in aircrew when compared with CACS and may reduce downstream testing, allowing a more efficacious approach to CAD assessment in military aircrew.Parsons I, Pavitt C, Chamley R, d'Arcy J, Nicol E. CT coronary angiography vs. coronary artery calcium scoring for the occupational assessment of military aircrew. Aerosp Med Hum Perform. 2017; 88(2):76-81.

  6. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  7. 320-detector row CT coronary angiography in patients with arrhythmia

    International Nuclear Information System (INIS)

    Lu Li; Zhang Zhaoqi; Xu Lei; Yang Lin

    2011-01-01

    Objective: To evaluate the feasibility of CT coronary angiography (CTCA) in patients with arrhythmia using 320-detector row CT. Methods: Thirty-one patients with persistent atrial fibrillation and 8 patients with premature ventricular contraction were enrolled in this study. All patients underwent 320- detector row CTCA. CT image quality was evaluated with 4-point grading scale by two radiologists. Inter- observer agreement was evaluated by Kappa statistics. The radiation dose was calculated. Results: In total 510 coronary segments, 496 (97.2%) segments met diagnostic standard. The mean effective dose was (12.7±4.8) mSv in this study. There was a good agreement in image quality scoring between the two reviewers (Kappa = 0.72). Conclusion: 320-detector row CTCA is feasible in patients with atrial fibrillation and premature ventricular contraction. Arrhythmia may not be considered as a contraindication to CTCA. (authors)

  8. Phantom-based standardization of CT angiography images for spot sign detection

    International Nuclear Information System (INIS)

    Morotti, Andrea; Rosand, Jonathan; Romero, Javier M.; Jessel, Michael J.; Vashkevich, Anastasia; Schwab, Kristin; Greenberg, Steven M.; Hernandez, Andrew M.; Boone, John M.; Burns, Joseph D.; Shah, Qaisar A.; Bergman, Thomas A.; Suri, M.F.K.; Ezzeddine, Mustapha; Kirmani, Jawad F.; Agarwal, Sachin; Hays Shapshak, Angela; Messe, Steven R.; Venkatasubramanian, Chitra; Palmieri, Katherine; Lewandowski, Christopher; Chang, Tiffany R.; Chang, Ira; Rose, David Z.; Smith, Wade; Hsu, Chung Y.; Liu, Chun-Lin; Lien, Li-Ming; Hsiao, Chen-Yu; Iwama, Toru; Afzal, Mohammad Rauf; Qureshi, Adnan I.; Cassarly, Christy; Hebert Martin, Renee; Goldstein, Joshua N.

    2017-01-01

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p < 0.001). All spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion. (orig.)

  9. Phantom-based standardization of CT angiography images for spot sign detection.

    Science.gov (United States)

    Morotti, Andrea; Romero, Javier M; Jessel, Michael J; Hernandez, Andrew M; Vashkevich, Anastasia; Schwab, Kristin; Burns, Joseph D; Shah, Qaisar A; Bergman, Thomas A; Suri, M Fareed K; Ezzeddine, Mustapha; Kirmani, Jawad F; Agarwal, Sachin; Shapshak, Angela Hays; Messe, Steven R; Venkatasubramanian, Chitra; Palmieri, Katherine; Lewandowski, Christopher; Chang, Tiffany R; Chang, Ira; Rose, David Z; Smith, Wade; Hsu, Chung Y; Liu, Chun-Lin; Lien, Li-Ming; Hsiao, Chen-Yu; Iwama, Toru; Afzal, Mohammad Rauf; Cassarly, Christy; Greenberg, Steven M; Martin, Renee' Hebert; Qureshi, Adnan I; Rosand, Jonathan; Boone, John M; Goldstein, Joshua N

    2017-09-01

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion.

  10. Phantom-based standardization of CT angiography images for spot sign detection

    Energy Technology Data Exchange (ETDEWEB)

    Morotti, Andrea; Rosand, Jonathan [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Romero, Javier M. [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Neuroradiology Service, Department of Radiology, Massachusetts General Hospital, Boston, MA (United States); Jessel, Michael J.; Vashkevich, Anastasia; Schwab, Kristin; Greenberg, Steven M. [Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Hernandez, Andrew M.; Boone, John M. [University of California Davis, Department of Radiology, Sacramento, CA (United States); Burns, Joseph D. [Lahey Hospital and Medical Center, Department of Neurology, Burlington, MA (United States); Shah, Qaisar A. [Abington Memorial Hospital, Abington, PA (United States); Bergman, Thomas A. [Hennepin County Medical Center, Minneapolis, MN (United States); Suri, M.F.K. [St. Cloud Hospital, St. Cloud, MN (United States); Ezzeddine, Mustapha [University of Minnesota, Minneapolis, MN (United States); Kirmani, Jawad F. [JFK Medical Center, Stroke and Neurovascular Center, Edison, NJ (United States); Agarwal, Sachin [Columbia University Medical Center, New York, NY (United States); Hays Shapshak, Angela [University of Alabama at Birmingham, Birmingham, AL (United States); Messe, Steven R. [University of Pennsylvania, Philadelphia, PA (United States); Venkatasubramanian, Chitra [Stanford University, Stanford, CA (United States); Palmieri, Katherine [The University of Kansas Health System, Kansas City, KS (United States); Lewandowski, Christopher [Henry Ford Hospital, Detroit, MI (United States); Chang, Tiffany R. [University of Texas Medical School, Houston, TX (United States); Chang, Ira [Colorado Neurological Institute, Swedish Medical Center, Englewood, CO (United States); Rose, David Z. [Tampa General Hospital, University of South Florida College of Medicine, Tampa, FL (United States); Smith, Wade [UCSF Medical Center, San Francisco, CA (United States); Hsu, Chung Y.; Liu, Chun-Lin [China Medical University Hospital, Taichung (China); Lien, Li-Ming; Hsiao, Chen-Yu [Shin Kong Wu Ho-Su Memorial Hospital, Taipei (China); Iwama, Toru [Gifu University Hospital, Gifu (Japan); Afzal, Mohammad Rauf; Qureshi, Adnan I. [University of Minnesota, Zeenat Qureshi Stroke Research Center, Minneapolis, MN (United States); Cassarly, Christy; Hebert Martin, Renee [Medical University of South Carolina, Department of Public Health Sciences, Charleston, SC (United States); Goldstein, Joshua N. [Harvard Medical School, Division of Neurocritical Care and Emergency Neurology, Department of Neurology, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, J. P. Kistler Stroke Research Center, Massachusetts General Hospital, Boston, MA (United States); Harvard Medical School, Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA (United States); Collaboration: ATACH-II and NETT Investigators

    2017-09-15

    The CT angiography (CTA) spot sign is a strong predictor of hematoma expansion in intracerebral hemorrhage (ICH). However, CTA parameters vary widely across centers and may negatively impact spot sign accuracy in predicting ICH expansion. We developed a CT iodine calibration phantom that was scanned at different institutions in a large multicenter ICH clinical trial to determine the effect of image standardization on spot sign detection and performance. A custom phantom containing known concentrations of iodine was designed and scanned using the stroke CT protocol at each institution. Custom software was developed to read the CT volume datasets and calculate the Hounsfield unit as a function of iodine concentration for each phantom scan. CTA images obtained within 8 h from symptom onset were analyzed by two trained readers comparing the calibrated vs. uncalibrated density cutoffs for spot sign identification. ICH expansion was defined as hematoma volume growth >33%. A total of 90 subjects qualified for the study, of whom 17/83 (20.5%) experienced ICH expansion. The number of spot sign positive scans was higher in the calibrated analysis (67.8 vs 38.9% p < 0.001). All spot signs identified in the non-calibrated analysis remained positive after calibration. Calibrated CTA images had higher sensitivity for ICH expansion (76 vs 52%) but inferior specificity (35 vs 63%) compared with uncalibrated images. Normalization of CTA images using phantom data is a feasible strategy to obtain consistent image quantification for spot sign analysis across different sites and may improve sensitivity for identification of ICH expansion. (orig.)

  11. Comparison of four different collateral scores in acute ischemic stroke by CT angiography.

    Science.gov (United States)

    Seker, Fatih; Potreck, Arne; Möhlenbruch, Markus; Bendszus, Martin; Pham, Mirko

    2016-11-01

    Multiple scores have been described for the assessment of collateralization in acute ischemic stroke. Currently, there is no gold standard for collateral assessment by CT angiography (CTA). This study compared four frequently used collateral scores with regard to their correlation with early infarct core and mismatch ratio. 30 consecutive patients with acute occlusion of the M1 segment or terminal carotid artery were reviewed retrospectively. Collaterals were assessed using dynamic and also single-phase CTA according to grading systems by the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR), Alberta Stroke Program Early CT Score (ASPECTS) (on collaterals), Christoforidis et al and Miteff et al. The Christoforidis and ASITN/SIR scores, which were initially designed for conventional angiography, were adapted to be applicable to CTA. The scores were compared with respect to early infarct core and mismatch ratio in perfusion CT estimated by RAPID software using Spearman correlation. ASITN/SIR and ASPECTS collateral scores showed good correlation with early infarct core (rho=-0.696, p<0.001 and rho=-0.677, p<0.001) and mismatch ratio (rho=0.609, p<0.001 and rho=0.581, p<0.001). In contrast, the Christoforidis and Miteff scores correlated less well with infarct core (rho=0.245, p=0.191 and rho=-0.272, p=0.145, respectively) and mismatch ratio (rho=-0.329, p=0.075 and rho=0.279, p=0.135, respectively). ASPECTS and ASITN/SIR showed excellent cross-correlation (rho=0.901, p<0.001). Compared with the Christoforidis and Miteff scores, the modified ASITN/SIR and ASPECTS collateral scores showed consistently higher correlation with the extent of early infarct core and mismatch volume. This is probably because these scores evaluate the extent and delay of vascular enhancement in the affected territory rather than the backflow of contrast medium to the occlusion. Published by the BMJ Publishing Group Limited. For

  12. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    International Nuclear Information System (INIS)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei

    2002-01-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  13. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  14. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  15. Diagnostic value of multislice computed tomography angiography in coronary artery disease: A meta-analysis

    International Nuclear Information System (INIS)

    Sun Zhonghua; Jiang Wen

    2006-01-01

    Purpose: To perform a meta-analysis of the diagnostic value of multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PubMed and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analyzed at segment-, vessel- and patient-based assessment. Results: 47 studies (67 comparisons) met the criteria and were included in our study. Pooled overall sensitivity, specificity and 95% confidence interval for MSCT angiography in the detection of CAD were 83% (79%, 89%), 93% (91%, 96%) at segment-based analysis; 90% (87%, 94%), 87% (80%, 93%) at vessel-based analysis; and 91% (88%, 95%), 86% (81%, 92%) at patient-based analysis, respectively. Diagnostic accuracy of MSCT angiography in evaluating assessable segments was significantly improved with 64-slice scanners when compared to that with 4- and 16-slice scanners (p < 0.05). Conclusion: Our meta-analysis showed that MSCT angiography has potential diagnostic accuracy in the detection of CAD. Diagnostic performance of MSCT angiography has been significantly improved with the latest 64-slice CT, with resultant high qualitative and quantitative diagnostic accuracy. 16-slice CT was limited in spatial resolution which makes it difficult to perform quantitative assessment of coronary artery stenoses

  16. Three dimensional CT angiography (3D-CTA) in ruptured aneurysm surgery on acute stage

    International Nuclear Information System (INIS)

    Matsumoto, Masato; Endo, Yuji; Nakano, Masayuki

    1998-01-01

    We evaluated three-dimensional CT angiography (3D-CTA) for the treatment of acutely ruptured cerebral aneurysms. Sixty patients with subarachnoid hemorrhage from cerebral aneurysms were investigated both by 3D-CTA and conventional angiography and 26 patients were studied using 3D-CTA without conventional angiography. In the 60 cases, both 3D-CTA and the conventional angiography revealed 100% accuracy in diagnosing ruptured aneurysms, and 3D-CTA and the conventional angiography showed 96% and 92% accuracy for unruptured aneurysms respectively. 3D-CTA was equal or superior to the conventional angiography. Based on these data, since December, 1996, we have operated on 26 consecutive patients with ruptured aneurysms located in the anterior circulation of the circle of Willis, using 3D-CTA without conventional angiography. Thirty-one aneurysms, including 5 associated unruptured aneurysms, were visualized by 3D-CTA and verified at surgery. All aneurysms were clipped successfully. We think that it will be possible to operate on most ruptured aneurysms using only 3D-CTA without the conventional angiography except for the cases of the following situations: if a cerebral infarction is present, conventional angiography is required to evaluate for a stenotic or occlusive lesion of the intracranial arteries, cervical carotid, or vertebral arteries; in cases of giant or large aneurysms, the dynamic information provided by the conventional angiography is needed in case bypass surgery is necessary; and for aneurysms close to bony structures, such as an internal carotid-ophthalmic artery aneurysm, conventional angiography is necessary. (author)

  17. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    Science.gov (United States)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  18. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hyeon Hoe [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors.

  19. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    International Nuclear Information System (INIS)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung; Kim, Hyeon Hoe

    2008-01-01

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors

  20. Optimal Monochromatic Energy Levels in Spectral CT Pulmonary Angiography for the Evaluation of Pulmonary Embolism

    Science.gov (United States)

    Wu, Huawei; Zhang, Qing; Hua, Jia; Hua, Xiaolan; Xu, Jianrong

    2013-01-01

    Background The aim of this study was to determine the optimal monochromatic spectral CT pulmonary angiography (sCTPA) levels to obtain the highest image quality and diagnostic confidence for pulmonary embolism detection. Methods The Institutional Review Board of the Shanghai Jiao Tong University School of Medicine approved this study, and written informed consent was obtained from all participating patients. Seventy-two patients with pulmonary embolism were scanned with spectral CT mode in the arterial phase. One hundred and one sets of virtual monochromatic spectral (VMS) images were generated ranging from 40 keV to 140 keV. Image noise, clot diameter and clot to artery contrast-to-noise ratio (CNR) from seven sets of VMS images at selected monochromatic levels in sCTPA were measured and compared. Subjective image quality and diagnostic confidence for these images were also assessed and compared. Data were analyzed by paired t test and Wilcoxon rank sum test. Results The lowest noise and the highest image quality score for the VMS images were obtained at 65 keV. The VMS images at 65 keV also had the second highest CNR value behind that of 50 keV VMS images. There was no difference in the mean noise and CNR between the 65 keV and 70 keV VMS images. The apparent clot diameter correlated with the keV levels. Conclusions The optimal energy level for detecting pulmonary embolism using dual-energy spectral CT pulmonary angiography was 65–70 keV. Virtual monochromatic spectral images at approximately 65–70 keV yielded the lowest image noise, high CNR and highest diagnostic confidence for the detection of pulmonary embolism. PMID:23667583

  1. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  2. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    Directory of Open Access Journals (Sweden)

    Moritz Kaup

    2016-12-01

    Full Text Available Background Computed tomography (CT low-dose (LD imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA. Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR and signal-to-noise ratios (SNR were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy. Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768. Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4. Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

  3. Low tube voltage and low contrast material volume cerebral CT angiography

    International Nuclear Information System (INIS)

    Luo, Song; Zhang, Long Jiang; Lu, Guang Ming; Meinel, Felix G.; McQuiston, Andrew D.; Zhou, Chang Sheng; Qi, Li; Schoepf, U.J.

    2014-01-01

    To evaluate the image quality, radiation dose and diagnostic accuracy of low kVp and low contrast material volume cerebral CT angiography (CTA) in intracranial aneurysm detection. One hundred twenty patients were randomly divided into three groups (n = 40 for each): Group A, 70 ml iodinated contrast agent/120 kVp; group B, 30 ml/100 kVp; group C, 30 ml/80 kVp. The CT numbers, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Subjective image quality was evaluated. For patients undergoing DSA, diagnostic accuracy of CTA was calculated with DSA as reference standard and compared. CT numbers of ICA and MCA were higher in groups B and C than in group A (P < 0.01). SNR and CNR in groups A and B were higher than in group C (both P < 0.05). There was no difference in subjective image quality among the three groups (P = 0.939). Diagnostic accuracy for aneurysm detection among these groups had no statistical difference (P = 1.00). Compared with group A, the radiation dose of groups B and C was decreased by 45 % and 74 %. Cerebral CTA at 100 or 80 kVp using 30 ml contrast agent can obtain diagnostic image quality with a low radiation dose while maintaining the same diagnostic accuracy for aneurysm detection. (orig.)

  4. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    International Nuclear Information System (INIS)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge

    2014-01-01

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  5. Effects of dual-energy CT with non-linear blending on abdominal CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Sulan; Wang, Chaoqin; Jiang, Xiao Chen; Xu, Ge [Dept. of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou (China)

    2014-08-15

    To determine whether non-linear blending technique for arterial-phase dual-energy abdominal CT angiography (CTA) could improve image quality compared to the linear blending technique and conventional 120 kVp imaging. This study included 118 patients who had accepted dual-energy abdominal CTA in the arterial phase. They were assigned to Sn140/80 kVp protocol (protocol A, n = 40) if body mass index (BMI) < 25 or Sn140/100 kVp protocol (protocol B, n = 41) if BMI ≥ 25. Non-linear blending images and linear blending images with a weighting factor of 0.5 in each protocol were generated and compared with the conventional 120 kVp images (protocol C, n = 37). The abdominal vascular enhancements, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were assessed. Statistical analysis was performed using one-way analysis of variance test, independent t test, Mann-Whitney U test, and Kruskal-Wallis test. Mean vascular attenuation, CNR, SNR and subjective image quality score for the non-linear blending images in each protocol were all higher compared to the corresponding linear blending images and 120 kVp images (p values ranging from < 0.001 to 0.007) except for when compared to non-linear blending images for protocol B and 120 kVp images in CNR and SNR. No significant differences were found in image noise among the three kinds of images and the same kind of images in different protocols, but the lowest radiation dose was shown in protocol A. Non-linear blending technique of dual-energy CT can improve the image quality of arterial-phase abdominal CTA, especially with the Sn140/80 kVp scanning.

  6. Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement

    International Nuclear Information System (INIS)

    Ruiz, Yolanda; Caballero, Paloma; Caniego, Jose Luis; Friera, Alfonsa; Olivera, Maria Jose; Tagarro, David; Alvarez-Sala, Rodolfo

    2003-01-01

    The objective of this prospective study was to evaluate the sensitivity, specificity, positive and negative predictive values, and interobserver agreement in the diagnosis of pulmonary embolism with helical CT, compared with pulmonary angiography, for both global results and for selective vascular territories. Helical CT and pulmonary angiography were performed on 66 consecutive patients with clinical suspicion of pulmonary embolism. The exams were blindly interpreted by a vascular radiologist and by two independent thoracic radiologists. Results were analyzed for the final diagnosis as well as separately for 20 different arterial territories in each patient. Pulmonary angiography revealed embolism in 25 patients (38%); 48% were main, 28% lobar, 16% segmental, and 8% subsegmental. The sensitivity, specificity, and positive and negative predictive values of helical CT for observer 1 were, respectively, 91, 81.5, 75, and 94%; in 7.5% of the patients the exam was considered indeterminate. For observer 2 the values were, respectively, 88, 86, 81.5, and 91%; in 9% of the patients the exam was considered indeterminate. Main arteries were considered as non-valuable in 0-0.8%, the lobar in 1.5%, the segmental in 7.5-8.5%, and the subsegmental in 55-60%. Interobserver agreement for the final diagnosis was 80% (kappa 0.65). For each vascular territory, this was 98% (kappa 0.91) for main arteries, 92% (kappa 0.78) for lobar arteries, 79% (kappa 0.56) for segmental arteries, and 59% (kappa 0.21) for subsegmental arteries. Helical CT is a reliable method for pulmonary embolism diagnosis, with good interobserver agreement for main, lobar, and segmental territories. Worse results are found for subsegmental arteries, with high incidence of non-valuable branches and poor interobserver agreement. (orig.)

  7. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna [Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow (India)

    2010-06-15

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  8. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    Science.gov (United States)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  9. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    International Nuclear Information System (INIS)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  10. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

    International Nuclear Information System (INIS)

    Beeres, Martin; Schell, Boris; Mastragelopoulos, Aristidis; Kerl, Josef Matthias; Gruber-Rouh, Tatjana; Lee, Clara; Siebenhandl, Petra; Bodelle, Boris; Zangos, Stephan; Vogl, Thomas J.; Jacobi, Volkmar; Bauer, Ralf W.; Herrmann, Eva

    2012-01-01

    To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). (orig.)

  11. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  12. Preliminary study of the scan-delay-time during the combined examation of CT perfusion and CT angiography after contrast media administration in cerebral and cervical CT angiography

    International Nuclear Information System (INIS)

    Cai Wu; Gong Jianping; Zhu Jiangtao; Qiao Fang; Chen Guangqiang; Zhang Bo; Yi Bixing; Qian Minghui

    2010-01-01

    Objective: To discuss the feasibility of the time to peak of cerebral CT perfusion (CTP) in predicting the scan-delay-time after contrast media administration in cerebral and cervical CT angiography (CTA). Methods: Retrospective Analysis was performed in eighty patients who had been examined with cerebral and cervical CTA, they were divided randomly into two groups. Group A:40 patients were performed by the method of experience of 20 seconds as scan-delay-time. Group B:the other 40 patients were examined with the combination scanning technology of CTP-CTA. They were all measured with enhancement value of CT in the M1 segment of left middle cerebral artery, superior sagittal sinus , left common carotid artery adjacent to the fourth cervical vertebrace and internal jugular vein, and then calculate the difference between the arterys and the veins in the same layer. Statistical significance was determined with t test. Results: (1)The enhancement value of CT in the cerebral and cervical artery vessels and the resolving power between the arterys and the veins in the same layer of group B were higher than that in group A. (2) Group B whose cerebral and cervical artery vessels rescontructed from the raw CT data set showed clearly; There were an advance in 3 cases (7.5%), a delay in 5 cases (12.5%) in group A whose cerebral and cervical artery vessels rescontructed from the raw CT data set didn't show clearly.Conclusion It's a satisfactory method based on successful cerebral and cervical CTA study to take the time to peak in CT perfusion as the scan-delay-time during the combined examination of CTP and CTA with 64-detector spiral CT. (authors)

  13. Quantification of coronary artery stenoses. Comparison of 64-slice and dual source CT angiography with cardiac catheterization

    International Nuclear Information System (INIS)

    Busch, Stephanie; Nikolaou, K.; Johnson, T.; Rist, C.; Knez, A.; Reiser, M.; Becker, C.

    2007-01-01

    Until now stenoses of the coronary arteries have been evaluated visually with CT angiography. Therefore, the results were highly dependent on subjective factors inherent in the examiner. New software tools for semiquantitative analysis (CT-QCA, quantitative coronary assessment) might be adequate to improve the diagnostic accuracy und reproducibility. CTAs of 20 patients were analyzed. Ten patients each were evaluated using 64-slice CT (64SCT) and dual source CT (DSCT) (Somatom Sensation 64 and Somatom Definition, Siemens Medical Solutions, Forchheim), respectively. Two radiologists independently evaluated the data visually and with the help of a software tool (Syngo Circulation, Siemens Medical Solutions, Forchheim). The results of the quantitative assessment of the invasive heart catheterization served as the reference standard. Sensitivity and specificity as well as the correlation coefficient, the systematic error, and the interobserver agreement (kappa) were determined. In each of both patient groups 12 stenoses were detected. For the detection of stenoses >75%, sensitivity and specificity for the visual evaluation using the 64SCT were 100% and 90%, and with the CT-QCA both were 100%. For the DSCT sensitivity and specificity were 100% for both the visual and semiautomated evaluation. The Bland-Altman plot of the results of the 64SCT showed an overestimation of 3.3% (±62.7%/56.2%) compared to the heart catheterization. The results of the DSCT exhibited an overestimation of 6.2% (±33.1%/19.8%). The interobserver agreement of the CT-QCA and the visual evaluation showed a kappa value of 0.75 and for DSCT of 1.0. The results showed a good correlation of grading stenosis between the software-assisted evaluation and the results of the coronary catheter angiography. The promising results of the DSCT are due to a superior temporal resolution compared to the 64SCT. Confirmation of these data by trials in larger patient collectives is warranted. (orig.) [de

  14. Generalised brain edema and brain infarct in ergotamine abuse: Visualization by CT, MR and angiography

    International Nuclear Information System (INIS)

    Toedt, C.; Hoetzinger, H.; Salbeck, R.; Beyer, H.K.

    1989-01-01

    Abuse of ergotamine can release a generalised brain edema and brain infarctions. This can be visualized by CT, MR and angiography. The reason, however, can only be found in the patients history. (orig.) [de

  15. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Wiesinger, Benjamin; Tepe, Gunnar; Luz, Oliver; Kopp, Andreas F.; Claussen, Claus D.; Duda, Stephan H.

    2007-01-01

    Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature. (orig.)

  16. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reichelt, Angela [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany)], E-mail: Reichelt.Angela@mh-hannover.de; Hoeper, Marius M. [Department of Respiratory Medicine, Hannover Medical School (Germany); Galanski, Michael [Department of Diagnostic Radiology, Hannover Medical School, Carl Neuberg Str. 1, 30625 Hannover (Germany); Keberle, Marc [Department of Diagnostic Radiology and Nuclear Medicine, Bruederkrankenhaus St. Josef Paderborn (Germany)

    2009-07-15

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  17. Chronic thromboembolic pulmonary hypertension: Evaluation with 64-detector row CT versus digital substraction angiography

    International Nuclear Information System (INIS)

    Reichelt, Angela; Hoeper, Marius M.; Galanski, Michael; Keberle, Marc

    2009-01-01

    The aim of the study was to evaluate the role of 64-row CT in the diagnostic workup of patients with chronic thromboembolic pulmonary hypertension (CTEPH) using digital substraction angiography (DSA) as the method of diagnostic reference. CT and DSA studies of 27 patients (54 main, 162 lobar and 540 segmental arteries) with a clinical suspicion of CTEPH were included in this retrospective and blinded analysis. Axial images and multiplanar thin maximum intensity projections (MIPs) (3 mm) were consequently used for exact image interpretation whereas additional reconstructed thick MIPs gave an overview of the entire vascular tree comparable to DSA. Sensitivity and specificity of CT regarding CTEPH-related pathological changes in general were 98.3% and 94.8% at main/lobar level and 94.1% and 92.9% at segmental level, respectively. Sensitivity and specificity of CT regarding the different pathological criteria of CTEPH (complete obstruction, intimal irregularities, bands and webs, indirect signs) were 88.9-100% and 96.1-100% at main/lobar level and 84.3-90.5% and 92-98.7% at segmental level, respectively. Our results show that CT is an accurate and reliable non-invasive alternative to conventional DSA in the diagnostic workup in patients with CTEPH.

  18. Closing in on the K Edge : Coronary CT Angiography at 100, 80, and 70 kV-Initial Comparison of a Second-versus a Third-Generation Dual-Source CT System

    NARCIS (Netherlands)

    Meyer, Mathias; Haubenreisser, Holger; Schoepf, U. Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O.; Henzler, Thomas

    2014-01-01

    Purpose: To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. Materials and Methods: All

  19. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    International Nuclear Information System (INIS)

    Anders, Katharina; Uder, Michael; Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias

    2013-01-01

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses ≥ 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  20. Multislice CT coronary angiography: evaluation of an automatic vessel detection tool

    International Nuclear Information System (INIS)

    Dewey, M.; Schnapauff, D.; Lembcke, A.; Hamm, B.; Rogalla, P.; Laule, M.; Borges, A.C.; Rutsch, W.

    2004-01-01

    Purpose: To investigate the potential of a new detection tool for multisliceCT (MSCT) coronary angiography with automatic display of curved multiplanar reformations and orthogonal cross-sections. Materials and Methods: Thirty-five patients were consecutively enrolled in a prospective intention-to-diagnose study and examined using a MSCT scanner with 16 x 0.5 mm detector collimation and 400 ms gantry rotation time (Aquilion, Toshiba). A multisegment algorithm using up to four segments was applied for ECG-gated reconstruction. Automatic and manual detection of coronary arteries was conducted using the coronary artery CT protocol of a workstation (Vitrea 2, Version 3.3, Vital Images) to detect significant stenoses (≥50%) in all segments of ≥1.5 mm in diameter. Each detection tool was used by one reader who was blinded to the results of the other detection method and the results of conventional coronary angiography. Results: The overall sensitivity, specificity, nondiagnostic rate, and accuracy of the automatic and manual approach were 90 vs. 94%, 89 vs. 84%, 6 vs. 6%, and 89 vs. 88%, respectively (p=n.s.). The vessel length detected with the automatic and manual approach were highly correlated for the left main/left anterior descending (143±30 vs. 146±24 mm, r=0.923, p [de

  1. Reduction of the estimated radiation dose and associated patient risk with prospective ECG-gated 256-slice CT coronary angiography

    International Nuclear Information System (INIS)

    Efstathopoulos, E P; Kelekis, N L; Pantos, I; Brountzos, E; Argentos, S; Grebac, J; Ziaka, D; Seimenis, I; Katritsis, D G

    2009-01-01

    Computed tomography (CT) coronary angiography has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but high radiation doses have been reported. Prospective ECG-gating using a 'step-and-shoot' axial scanning protocol has been shown to reduce radiation exposure effectively while maintaining diagnostic accuracy. 256-slice scanners with 80 mm detector coverage have been currently introduced into practice, but their impact on radiation exposure has not been adequately studied. The aim of this study was to assess radiation doses associated with CT coronary angiography using a 256-slice CT scanner. Radiation doses were estimated for 25 patients scanned with either prospective or retrospective ECG-gating. Image quality was assessed objectively in terms of mean CT attenuation at selected regions of interest on axial coronary images and subjectively by coronary segment quality scoring. It was found that radiation doses associated with prospective ECG-gating were significantly lower than retrospective ECG-gating (3.2 ± 0.6 mSv versus 13.4 ± 2.7 mSv). Consequently, the radiogenic fatal cancer risk for the patient is much lower with prospective gating (0.0176% versus 0.0737%). No statistically significant differences in image quality were observed between the two scanning protocols for both objective and subjective quality assessments. Therefore, prospective ECG-gating using a 'step-and-shoot' protocol that covers the cardiac anatomy in two axial acquisitions effectively reduces radiation doses in 256-slice CT coronary angiography without compromising image quality.

  2. Comparative assessment of image quality for coronary CT angiography with iobitridol and two contrast agents with higher iodine concentrations: iopromide and iomeprol. A multicentre randomized double-blind trial

    Energy Technology Data Exchange (ETDEWEB)

    Achenbach, Stephan [Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Department of Cardiology, Erlangen (Germany); Paul, Jean-Francois [Centre Chirurgical Marie Lannelongue, Department of Radiology, Le Plessis Robinson (France); Laurent, Francois [University of Bordeaux, Centre de Recherche Cardio-Thoracique de Bordeaux, U1045, Bordeaux (France); CHU de Bordeaux, Service d' Imagerie Thoracique et Cardiovasculaire, Pessac (France); Becker, Hans-Christoph [University Hospital Grosshadern, Department of Clinical Radiology, Munich (Germany); Rengo, Marco [Sapienza - University of Rome, ICOT Hospital, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy); Caudron, Jerome [University Hospital of Rouen, Department of Radiology, Rouen (France); Leschka, Sebastian [Saint Gallen Hospital, Department of Radiology, Saint Gallen (Switzerland); Vignaux, Olivier [Cochin Hospital, Department of Radiology, Paris (France); Knobloch, Gesine [La Charite, Department of Radiology, Berlin (Germany); Benea, Giorgio [Ospedale del Delta, Ferrara (Italy); Schlosser, Thomas [Elisabeth-Krankenhaus Hospital, Essen (Germany); Andreu, Jordi [Hospital Vall d' Hebron, Barcelona (Spain); Cabeza, Beatriz [Hospital Clinico San Carlos, Madrid (Spain); Jacquier, Alexis [La Timone Adult Hospital, Department of Radiology, Marseille (France); Souto, Miguel [Complejo Hospitalario Universitario, Santiago de Compostela (Spain); Revel, Didier [Louis Pradel Hospital, Department of Radiology, Lyon (France); Qanadli, Salah Dine [University of Lausanne, Department of Radiology, Lausanne (Switzerland); Cademartiri, Filippo [Giovanni XXIII Hospital, Department of Radiology, Monastier di Treviso (Italy); Collaboration: X-ACT Study Group

    2017-02-15

    To demonstrate non-inferiority of iobitridol 350 for coronary CT angiography (CTA) compared to higher iodine content contrast media regarding rate of patients evaluable for the presence of coronary artery stenoses. In this multicentre trial, 452 patients were randomized to receive iobitridol 350, iopromide 370 or iomeprol 400 and underwent coronary CTA using CT systems with 64-detector rows or more. Two core lab readers assessed 18 coronary segments per patient regarding image quality (score 0 = non diagnostic to 4 = excellent quality), vascular attenuation, signal and contrast to noise ratio (SNR, CNR). Patients were considered evaluable if no segment had a score of 0. Per-patient, the rate of fully evaluable CT scans was 92.1, 95.4 and 94.6 % for iobitridol, iopromide and iomeprol, respectively. Non-inferiority of iobitridol over the best comparator was demonstrated with a 95 % CI of the difference of [-8.8 to 2.1], with a pre-specified non-inferiority margin of -10 %. Although average attenuation increased with higher iodine concentrations, average SNR and CNR did not differ between groups. With current CT technology, iobitridol 350 mg iodine/ml is not inferior to contrast media with higher iodine concentrations in terms of image quality for coronary stenosis assessment. (orig.)

  3. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  5. Renal computed angiography. Part I: Renal CT phlebography. Renal veins variants

    International Nuclear Information System (INIS)

    Al-Amin, M.; Krupev, M.; Hadjidekov, V.; Plachkov, I.

    2012-01-01

    The changing trend in renal surgery, transplantation and minimal invasive urology implies preprocedure evaluation of renal veins. Development of imaging methods offers new possibilities for venographic visualization. The goal of this study is to present authors experience in visualization of renal veins using 64 MDCT and to evaluate the utility in assessments of their variants. 128 patients (68 females and 60 males, mean age 53,3) with urological complaints underwent 64MDCT examination including CT angiography. Contrast enhancement includes 3-4ml/sec injection flow of 90 ml contrast medium followed by 20 ml saline at the same rate. In 23 out of 128 examined patients some of the common variants of the renal vein is found. 64 MDCT angiography visualize very well renal veins and becomes method of choice in preoperative assessment of renal vein anatomy. (authors)

  6. Development and validation of a CT-3D rotational angiography registration method for AVM radiosurgery

    International Nuclear Information System (INIS)

    Stancanello, Joseph; Cavedon, Carlo; Francescon, Paolo; Cerveri, Pietro; Ferrigno, Giancarlo; Colombo, Federico; Perini, Stefano

    2004-01-01

    In this paper a novel technique is proposed and validated for radiosurgery treatment planning of arteriovenous malformations (AVMs). The technique was developed for frameless radiosurgery by means of the CyberKnife, a nonisocentric, linac-based system which allows highly conformed isodose surfaces to be obtained, while also being valid for other treatment strategies. The technique is based on registration between computed tomography (CT) and three-dimensional rotational angiography (3DRA). Tests were initially performed on the effectiveness of the correction method for distortion offered by the angiographic system. These results determined the registration technique that was ultimately chosen. For CT-3DRA registration, a twelve-parameter affine transformation was selected, based on a mutual information maximization algorithm. The robustness of the algorithm was tested by attempting to register data sets increasingly distant from each other, both in translation and rotation. Registration accuracy was estimated by means of the 'full circle consistency test'. A registration quality index (expressed in millimeters) based on these results was also defined. A hybrid subtraction between CT and 3DRA is proposed in order to improve 3D reconstruction. Preprocessing improved the ability of the algorithm to find an acceptable solution to the registration process. The robustness tests showed that data sets must be manually prealigned within approximately 15 mm and 20 deg. with respect to all three directions simultaneously. Results of the consistency test showed agreement between the quality index and registration accuracy stated by visual inspection in 20 good and 10 artificially worsened registration processes. The quality index showed values smaller than the maximum voxel size (mean 0.8 mm compared to 2 mm) for all successful registrations, while it resulted in much greater values (mean 20 mm) for unsuccessful registrations. Once registered, the two data sets can be used for

  7. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  8. Maximum-intensity-projection CT angiography for evaluating head and neck tumors. Usefulness of helical CT and auto bone masking method

    International Nuclear Information System (INIS)

    Sakai, Osamu; Nakashima, Noriko; Ogawa, Chiaki; Shen, Yun; Takata, Yasunori; Azemoto, Shougo.

    1994-01-01

    Angiographic images of 10 adult patients with head and neck tumors were obtained by helical computed tomography (CT) using maximum intensity projection (MIP). In all cases, the vasculature of the head and neck region was directly demonstrated. In the head and neck, bone masking is a more important problem than in other regions. We developed an effective automatic bone masking method (ABM) using 2D/3D connectivity. Helical CT angiography with MIP and ABM provided accurate anatomic depiction, and was considered to be helpful in preoperative evaluation of head and neck tumors. (author)

  9. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Gouliamos, A.; Gotsis, E.; Vlahos, L.; Samara, C.; Kapsalaki, E.; Rologis, D.; Kapsalakis, Z.; Papavasiliou, C.

    1992-01-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  10. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A. (Dept. of Radiology, Athens Univ. (Greece)); Gotsis, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Vlahos, L. (Dept. of Radiology, Athens Univ. (Greece)); Samara, C. (Dept. of Radiology, Athens Univ. (Greece)); Kapsalaki, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Rologis, D. (Dept. of Neurosurgery, Athens General Hospital (Greece)); Kapsalakis, Z. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Papavasiliou, C. (Dept. of Radiology, Athens Univ. (Greece))

    1992-12-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  11. Arteriovenous fistula complicating iliac artery pseudo aneurysm: diagnosis by CT angiography.

    Science.gov (United States)

    Huawei, L; Bei, D; Huan, Z; Zilai, P; Aorong, T; Kemin, C

    2002-01-01

    Fistula formation to the inferior vena cava is a rare complication of aortic aneurysm which is often misdiagnosed clinically. In one hundred of reported arteriocaval fistulae, none was originating from the right common iliac artery. We report a case of ileo-caval fistula due to a iatrogenic pseudoaneurysm. High resolution 3D imaging using breath-hold CT angiography is highly specific in identifying the location, extent of the aortocaval fistula as well as the neighbouring anatomic structures.

  12. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    International Nuclear Information System (INIS)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille; Liozon, Eric; Ly, Kim Heang; Lambert, Marc; Aide, Nicolas; Manrique, Alain

    2017-01-01

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  13. Giant-cell arteritis. Concordance study between aortic CT angiography and FDG-PET/CT in detection of large-vessel involvement

    Energy Technology Data Exchange (ETDEWEB)

    Boysson, Hubert de; Dumont, Anael; Boutemy, Jonathan; Maigne, Gwenola; Martin Silva, Nicolas; Sultan, Audrey; Bienvenu, Boris; Aouba, Achille [Caen University Hospital, Department of Internal Medicine, Caen (France); Liozon, Eric; Ly, Kim Heang [Limoges University Hospital, Department of Internal Medicine, Limoges (France); Lambert, Marc [Lille University Hospital, Department of Internal Medicine, Lille (France); Aide, Nicolas [Caen University Hospital, Department of Nuclear Medicine, Caen (France); INSERM U1086 ' ' ANTICIPE' ' , Francois Baclesse Cancer Centre, Caen (France); Manrique, Alain [Caen University Hospital, Department of Nuclear Medicine, Caen (France); Normandy University, Caen (France)

    2017-12-15

    The purpose of our study was to assess the concordance of aortic CT angiography (CTA) and FDG-PET/CT in the detection of large-vessel involvement at diagnosis in patients with giant-cell arteritis (GCA). We created a multicenter cohort of patients with GCA diagnosed between 2010 and 2015, and who underwent both FDG-PET/CT and aortic CTA before or in the first ten days following treatment introduction. Eight vascular segments were studied on each procedure. We calculated concordance between both imaging techniques in a per-patient and a per-segment analysis, using Cohen's kappa concordance index. We included 28 patients (21/7 women/men, median age 67 [56-82]). Nineteen patients had large-vessel involvement on PET/CT and 18 of these patients also presented positive findings on CTA. In a per-segment analysis, a median of 5 [1-7] and 3 [1-6] vascular territories were involved on positive PET/CT and CTA, respectively (p = 0.03). In qualitative analysis, i.e., positivity of the procedure suggesting a large-vessel involvement, the concordance rate between both procedures was 0.85 [0.64-1]. In quantitative analysis, i.e., per-segment analysis in both procedures, the global concordance rate was 0.64 [0.54-0.75]. Using FDG-PET/CT as a reference, CTA showed excellent sensitivity (95%) and specificity (100%) in a per-patient analysis. In a per-segment analysis, sensitivity and specificity were 61% and 97.9%, respectively. CTA and FDG-PET/CT were both able to detect large-vessel involvement in GCA with comparable results in a per-patient analysis. However, PET/CT showed higher performance in a per-segment analysis, especially in the detection of inflammation of the aorta's branches. (orig.)

  14. Pulmonary CT angiography: optimization of contrast enhancement technique

    International Nuclear Information System (INIS)

    Ma Lianju; Tang Guangjian; Fu Jiazhen

    2012-01-01

    Objective: To derive and evaluate the formula of exactly calculating the contrast dosage used during pulmonary CT angiography (CTPA). Methods: Time density curves in 27 patients who underwent CTPA were collected and analyzed,the formula for calculating contrast dosage during CTPA was derived. 68 patients suspected of pulmonary embolism (PE) clinically but no PE on CTPA were divided randomly into group A, with bolus tracing technique (n=26), and group B, with small dose injection contrast test (SDCT) (n=42). The CT values of the right main pulmonary artery (RMPA), right upper pulmonary vein (RUPV), right posterior basal PA, right lower PV (RLPV) and the aorta were calculated. The total contrast dosage and the hard beam artifact in the SVC were compared between the two groups.Student's t test, Chi-square test and Mann-Whitney U test were used. Results: The ratio of the time from starting injection to enhancement peak of caudal end of SVC and the time to enhancement peak of the main pulmonary trunk was 0.65 ±0.09 (about 2/3), the formula for contrast dosage calculation was derived as (DTs/3 + STs/2) FR ml/s. The CT values of RMPA and RLPA between the two groups [(301 ±117), (329 ± 122) and (283 ±95), (277 ±98) HU respectively] were not significantly different (t=1.060, P=0.292; t=2.056, P=0.044), but the differences of CT values in the paired PA and PV between the two groups (median were 22.5, 58.0 and 170.5, 166.5 HU respectively) were significant (U=292, P=0.001 and U=325, P=0.005), contrast artifact of the SVC (grade 1-3) in group B (n=34, 7, 1 respectively) was significantly less than in group A (n=11, 10, 5 respectively, χ 2 =10.714, P=0.002), the contrast dosage injected in group A was ( 87.6 ± 7.3) ml, and in group B was (40.0 ±5.4) ml (P<0.01). Conclusion: CTPA with SDCT technique is superior to that with conventional bolus tracing technique regarding contrast dosage and contrast artifact in the SVC. (authors)

  15. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  16. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria; Duka, Ejona [University of Insubria, Interventional Radiology, Department of Radiology (Italy); Radaelli, Alessandro [Philips Healthcare (Netherlands); Rivolta, Nicola; Piffaretti, Gabriele [University of Insubria, Vascular Surgery Department (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [University of Insubria, Interventional Radiology, Department of Radiology (Italy)

    2016-01-15

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

  17. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    International Nuclear Information System (INIS)

    Ierardi, Anna Maria; Duka, Ejona; Radaelli, Alessandro; Rivolta, Nicola; Piffaretti, Gabriele; Carrafiello, Gianpaolo

    2016-01-01

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration

  18. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    Energy Technology Data Exchange (ETDEWEB)

    Ayyala, Rama S.; Lee, Edward Y. [Boston Children' s Hospital and Harvard Medical School, Department of Radiology, Boston, MA (United States); Zurakowski, David [Boston Children' s Hospital and Harvard Medical School, Departments of Anesthesiology and Surgery, Boston, MA (United States)

    2015-11-15

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  19. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children

    International Nuclear Information System (INIS)

    Ayyala, Rama S.; Lee, Edward Y.; Zurakowski, David

    2015-01-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  20. Quality of abdominal computed tomography angiography: hand versus mechanical intravenous contrast administration in children.

    Science.gov (United States)

    Ayyala, Rama S; Zurakowski, David; Lee, Edward Y

    2015-11-01

    Abdominal CT angiography has been increasingly used for evaluation of various conditions related to abdominal vasculature in the pediatric population. However, no direct comparison has evaluated the quality of abdominal CT angiography in children using hand versus mechanical administration of intravenous (IV) contrast agent. To compare hand versus mechanical administration of IV contrast agent in the quality of abdominal CT angiography in the pediatric population. We retrospectively reviewed the electronic medical record to identify pediatric patients (≤18 years) who had abdominal CT angiography between August 2012 and August 2013. The information obtained includes: (1) type of administration of IV contrast agent (hand [group 1] versus mechanical [group 2]), (2) size (gauge) of IV catheter, (3) amount of contrast agent administered and (4) rate of contrast agent administration (ml/s). Two reviewers independently performed qualitative and quantitative evaluation of abdominal CT angiography image quality. Qualitative evaluation of abdominal CT angiography image quality was performed by visual assessment of the degree of contrast enhancement in the region of interest (ROI) based on a 4-point scale. Quantitative evaluation of each CT angiography examination was performed by measuring the Hounsfield unit (HU) using an ROI within the abdominal aorta at two levels (celiac axis and the inferior mesenteric artery) for each child. Analysis of variance (ANOVA) using the F-test was applied to compare contrast enhancement within the abdominal aorta at two levels (celiac axis and inferior mesenteric artery) between hand administration and mechanical administration of IV contrast methods with adjustment for age. We identified 46 pediatric patients (24 male, 22 female; mean age 7.3 ± 5.5 years; range 5 weeks to 18 years) with abdominal CT angiography performed during the study period. Of these patients, 16 (35%; 1.7 ± 2.2 years; range 5 weeks to 5 years) had hand

  1. Choice ofoptimal phase for liver angiography and multi-phase scanning with multi-slice spiral CT

    International Nuclear Information System (INIS)

    Fang Hong; Song Yunlong; Bi Yongmin; Wang Dong; Shi Huiping; Zhang Wanshi; Zhu Hongxian; Yang Hua; Ji Xudong; Fan Hongxia

    2008-01-01

    Objective: To evaluate the efficacy of test bolus technique with multi-slice spiral CT (MSCT) for determining the optimal scan delay time in CT Hepatic artery (HA)-portal vein (PV) angiography and multi-phase scanning. Methods: MSCT liver angiography and multi-phase scanning were performed in 187 patients divided randomly into two groups. In group A (n=59), the scan delay time was set according to the subjective experiences of operators; in group B (n=128), the scan delay time was determined by test bolus technique. Abdominal aorta and superior mesenteric, vein were selected as target blood vessels, and 50 HU was set as enhancement threshold value. 20 ml contrast agent was injected intravenously and time-density curve of target blood vessels were obtained, then HA-PV scanning delay time were calculated respectively. The quality of CTA images obtained by using these 2 methods were compared and statistically analysed using Chi-square criterion. Results: For hepatic artery phase, the images of group A are: excellent in 34 (58%), good in 17 (29%), and poor in 8 (13%), while those of group B are excellent in 128(100%), good in 0(0%), and poor in 0(0%). For portal vein phase, the images of group A are: excellent in 23 (39%), good in 27 (46%), and poor in 9 (15%), while those of group B are excellent in 96 (75%), good in 28 (22%), and poor in 4 (3%) respectively. There was statistically significant difference between the ratios of image quality in group A and group B (χ 2 =14.97, 9.18, P< 0.05). Conclusion: Accurate scan delay time was best determined by using test bolus technique, which can improve the image quality of liver angiography and multi-phase scanning. (authors)

  2. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    Science.gov (United States)

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  3. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    Directory of Open Access Journals (Sweden)

    Marwa Sayed Meshaal

    Full Text Available Infective endocarditis (IE is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs. These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention.The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%. Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32% had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%. The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.Routine brain CT/CTA resulted in changes in the treatment plan in a significant

  4. Efficacy of 'fine' focal spot imaging in CT abdominal angiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Lawrence Chia Wei; Devapalasundaram, Ashwini; Ardley, Nicholas [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing, and Health Sciences, Victoria (Australia); Buchan, Kevin [Phillips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Huynh, Minh [RMIT University, School of Mathematical and Geospatial Sciences, Victoria (Australia)

    2014-12-15

    To assess the efficacy of fine focal spot imaging in calcification beam-hardening artefact reduction and vessel clarity on CT abdominal angiography (CTAA). Adult patients of any age and gender who presented for CTAA were included. Thirty-nine patients were examined with a standard focal spot size (SFSS) of 1 x 1 mm in the first 3 months while 31 consecutive patients were examined with a fine focal spot size (FFSS) of 1 x 0.5 mm in the following 3 months. Vessel clarity and calcification beam-hardening artefacts of the abdominal aorta, celiac axis, superior mesenteric artery, inferior mesenteric artery, renal arteries, and iliac arteries were assessed using a 5-point grading scale by two blinded radiologists randomly. Cohen's Kappa test indicated that on average, there was substantial agreement among reviewers for vessel wall clarity and calcification artefact grading. Mann-Whitney test showed that there was a significant difference between the two groups, with FFSS performing significantly better for vessel clarity (U, 6481.50; p < 0.001; r, 0.73) and calcification artefact reduction (U, 1916; p < 0.001; r, 0.77). Fine focus CT angiography produces images with better vessel wall clarity and less vessel calcification beam-hardening artefact. (orig.)

  5. Laparoscopic resection aided by preoperative 3-D CT angiography for rectosigmoid colon cancer associated with a horseshoe kidney: A case report.

    Science.gov (United States)

    Maeda, Yoshiaki; Shinohara, Toshiki; Nagatsu, Akihisa; Futakawa, Noriaki; Hamada, Tomonori

    2014-11-01

    We herein report a case of laparoscopic high anterior resection with D3 lymph node dissection for rectosigmoid colon cancer with a horseshoe kidney. A 65-year-old Japanese man referred to our hospital for rectosigmoid colon cancer was found to have a horseshoe kidney on a CT scan. On 3-D CT angiography, an aberrant renal artery was visualized feeding the renal isthmus that arises from the aorta just below the root of the inferior mesenteric artery (IMA). Laparoscopic anterior rectal resection with D3 lymph node dissection was performed. During the operation, the IMA, left ureter, left gonadal vessels and hypogastric nerve plexus could be seen passing over the horseshoe kidney isthmus. With the aid of preoperative 3-D CT angiography, the root of the IMA was identified on the temporal side of the isthmus and divided safely just above the hypogastric nerve. As a horseshoe kidney is often accompanied by aberrant renal arteries and/or abnormal running of the ureter, 3-D CT angiography is useful for determining the location of these structures and avoiding intraoperative injury. © 2014 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  6. Detection of thin wall regions of unruptured cerebral aneurysms by ECG synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 slices per rotation CT

    International Nuclear Information System (INIS)

    Fujita, Shigekiyo

    2004-01-01

    The objective of this study was to evaluate the capability of electrocardiogram (ECG) synchronous reconstruction 3D-CT angiography (4D-CTA) using 16 sequence MD-CT to detect weak portions of unruptured cerebral aneurysm. 4D-CT angiography of unruptured cerebral aneurysms was performed on 26 patients, 28 cerebral aneurysms, using 16 sequence MD-CT (GE, HiLight Matrix II). Contrast material of iodine (300 mg/ml) was injected over 30 sec period into the ante-cubital vein with a rate of 0.06 ml/Kg/sec. ECG synchronous reconstruction images (10 images at intervals of 10% between R-R of ECG) were generated (GE, Workstation Advantage 4.1). After careful inspection of the wall motion of an aneurysm from many aspects, cine images were made from several directions. Acquisition of data required 9 seconds, total volume data were generated within 15 minutes, and ECG synchronous reconstruction image processing was performed in about 5 minutes. Animation creation for one direction was completed within one minute. Even in 3-mm aneurysms, changes of its form and size within a heartbeat were fully observed. Timing of maximum and minimum sizes were also recognized. The pulsatile changes and nipple extent, bleb, daughter, and dome of aneurysms were well visualized. The projecting motion of the pulsatory enlargement of nipple was detected in nine cases, and definite increases in bleb sizes were detected in five cases. Since the easily reptured thin walled portion of a cerebral aneurysm can be recognized by this method, 4D-CT angiography is likely to become indispensable in judging how to cope with unruptured cerebral aneurysms, in deciding whether to operate or observe. (author)

  7. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R.; Gaetani, P.; Rodriguez y Baena, R.; Cecchini, A.; Infuso, L.

    1998-01-01

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 ± 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 ± 0.12 cm vs 1.09 ± 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients. (orig.)

  8. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  9. Diagnostic accuracy of coronary CT angiography using 3"r"d-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    International Nuclear Information System (INIS)

    Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U.J.; Caruso, Damiano; Tesche, Christian; Steinberg, Daniel H.; Bayer, Richard R.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N.; Nikolaou, Konstantin

    2017-01-01

    To investigate diagnostic accuracy of 3"r"d-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m"2, n = 37) and B (≥30 kg/m"2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3"r"d-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  10. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    Energy Technology Data Exchange (ETDEWEB)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin [Istanbul University, Department of Radiology, Cerrahpasa Medical Faculty (Turkey); Senyuz, Osman F. [Istanbul University, Department of Paediatric Surgery, Cerrahpasa Medical Faculty (Turkey); Dervisoglu, Sergulen [Istanbul University, Department of Pathology, Cerrahpasa Medical Faculty (Turkey)

    2006-11-15

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  11. Radiological evaluation with Doppler sonography and multidetector CT angiography in congenital hepatic arteriovenous malformation in a newborn

    International Nuclear Information System (INIS)

    Adaletli, Ibrahim; Kurugoglu, Sebuh; Kilic, Fahrettin; Senyuz, Osman F.; Dervisoglu, Sergulen

    2006-01-01

    Although hepatic arteriovenous malformations are rarely reported, they frequently have life-threatening complications such as cardiac failure and are associated with a high mortality rate. Consequently, accurate prenatal and early postnatal diagnosis is important and therapeutic procedures depend on the imaging features. We report the early postnatal sonographic, Doppler sonographic, multidetector CT and CT angiography findings of a congenital hepatic arteriovenous malformation in a newborn. (orig.)

  12. Role of coronary CT angiography in asymptomatic patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Kamimura, Munehiro; Moroi, Masao; Hiroe, Michiaki; Isobe, Mitsuaki

    2012-01-01

    Diabetic patients with coronary artery disease are often asymptomatic, making appropriate care of such patients difficult. The purpose of this study was to investigate the prevalence of coronary lesions in asymptomatic diabetic patients. Coronary computed tomography (CT) angiography was performed in 120 consecutive diabetic patients (90 of whom were men, mean age 65, mean HbA1c 7.2%). Images from patients whose coronary artery calcium scores (CAC scores) were less than 400 were subjected to stenosis and plaque analysis. Significant stenosis was defined as coronary artery stenosis >70%. High-risk plaque was defined as plaque having both a CT density <30 Hounsfield Units (HU) and showing positive remodeling. Significant stenoses were identified in 30.5% of the patients. High-risk plaques were identified in 17.1% of the patients. Less than half of the high-risk plaques were obstructive plaques. There was a statistically significant association between significant stenosis and high-risk plaque by chi-square test (P=0.022). We found significant stenosis even in patients whose CAC score =0 at a rate of 5.0%. Using univariate logistic-regression analysis, we found that coronary risk factors associated with significant stenosis and high-risk plaque were dyslipidemia (P=0.033) and current smoking (P=0.030), respectively. We report for the first time, the prevalence of high-risk plaques in the arteries of patients with asymptomatic diabetes, as assessed by coronary CT angiography. (author)

  13. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    International Nuclear Information System (INIS)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J.; Xu, J.

    2010-01-01

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 ± 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  14. Prospective ECG triggering versus low-dose retrospective ECG-gated 128-channel CT coronary angiography: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Q.; Yin, Y.; Hua, X.; Zhu, R.; Hua, J. [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China); Xu, J., E-mail: xujianr@hotmail.co [Department of Radiology, Renji Hospital, Shanghai Jiaotong University School of Medicine, Shanghai (China)

    2010-10-15

    Aim: To evaluate image quality and radiation dose for 128-detector prospective electrocardiogram (ECG)-gated computed tomography coronary angiography (CTCA) compared with a low-dose retrospective ECG-gated imaging protocol. Materials and methods: Thirty-one and 47 patients suspected of having coronary artery disease were enrolled into groups examined using prospective and low-dose retrospective ECG-gated CT protocols respectively. All examinations were performed on a 128-detector CT system (Definition AS, Siemens Healthcare, Forchheim, Germany). Prospective CTCA was performed using following parameters: tube voltage 100 kV; tube current 205 mAs; centre of acquisition window 70% of the RR interval. The tube current for low-dose retrospective ECG-gated CTCA was full dose during 40-70% of the RR interval and partial dose for the rest of RR interval. The pitch varied between 0.2 and 0.5 depending on heart rate and patient size. Image quality of coronary arteries was evaluated using a four-point grading scale. The signal-to-noise ratios (SNRs) of enhanced arteries and myocardium were also measured, corresponding contrast-to-noise ratios (CNRs) were calculated, and the radiation doses received were recorded. Results: There was a significant difference in the image quality scores between the retrospective and prospective gating protocols (Chi-square = 15.331, p = 0.009). There was no significant difference between the SNRs of the contrasted artery and myocardium in these two groups, but the CNRs were increased in the prospective group. The mean radiation dose of prospective gating group was 2.71 {+-} 0.67 mSv (range, 1.67-3.59 mSv), which was significantly lower than that of the retrospective group (p < 0.001). Conclusion: Prospective CT angiography can achieve lower radiation dose than that of low-dose retrospective CT angiography, with preserved image quality.

  15. Radiation Dose and Image Quality from Coronary Angiography in 320-Detecor Row CT

    International Nuclear Information System (INIS)

    Thanomphudsa, J.; Krisanachinda, A.; Tumkosit, M.

    2012-01-01

    Introduction: Coronary Computed Tomography Angiography examinations are increasing rapidly. New Computed Tomography has been developed to improve image quality with the patient dose reduction. The purpose of this study is to evaluate radiation dose and image quality of Coronary Computed Tomography Angiography in patients using 320-detector row CT. Methods: Forty-one patients referred for cardiac CT examinations at King Chulalongkorn Memorial Hospital were included in this study. All coronary computed tomographic angiography (CCTA) examinations were performed on the 320-detector row CT, Toshiba Aquilion One. Scanning protocol was investigated on dose estimates and image quality. Patients were scanned base on heart rate (HR) by HR 75 bpm use retrospective with dose modulation. Scanning parameters, kVp, mAs, HR, BMI, CTDIvol(mGy) and DLP(mGy.cm), were recorded to study the factors affecting the image quality and patient dose. And mA and kVp setting depend on BMI of the patient. Effective dose is calculated from DLP using specific conversion factor. The image quality was evaluated in 4 vessels by two radiologists. Noise assessment was also studied quantitatively. Results: The patient effective dose in prospective gating 70-80% was 3.6 ± 0.9 mSv, prospective gating 30-80% (1R-R) was 6.3 ± 1.9 mSv, and 30-80% (2R-R) was 10.8 ± 1.8 mSv and in retrospective with tube current modulation was 12.1± 7.7 mSv. Image noise was highest in PGT 70-80% 1R-R and decreased in RGT with tube current modulation, PGT 30-80% 1R-R and lowest in PGT 30-80% 2 R-R. And overall qualitative image quality was mostly good to excellent score. Discussion: The heart rate, heart rate variability and disease of the patient are affecting in the radiation dose and image quality so the suitable acquisition protocol used could be necessary. the effective dose and the image noise for the image quality. (author)

  16. Triphasic contrast injection improves evaluation of dual energy lung perfusion in pulmonary CT angiography

    International Nuclear Information System (INIS)

    Kerl, J. Matthias; Bauer, Ralf W.; Renker, Matthias; Weber, Eva; Weisser, Philipp; Korkusuz, Huedayi; Schell, Boris; Larson, Maya Christina; Kromen, Wolfgang; Jacobi, Volkmar

    2011-01-01

    Purpose: Lung perfusion analysis at dual energy CT (DECT) is sensitive to beam hardening artifacts from dense contrast material (CM). We compared two scan and four CM injection protocols in terms of severity of artifacts and attenuation levels in the thoracic vessels. Methods and materials: Data of 120 patients who had undergone dual source dual energy CT pulmonary angiography for suspected acute pulmonary embolism were evaluated. Group 1 (n = 30) was scanned in craniocaudal direction using 64 × 0.6 mm collimation; groups 2–4 (n = 30 each) were scanned in caudocranial direction using 14 × 1.2 mm collimation. In groups 1–3 biphasic injection protocols with different amounts of CM and NaCl were investigated. In group 4 a split-bolus protocol with an initial CM bolus of 50 ml followed by 30 ml of a 70%:30% NaCl/CM mixture and a 50 ml NaCl chaser bolus was used. CT density values in the subclavian vein (SV), superior vena cava (SVC), pulmonary artery tree (PA), and the descending aorta (DA) were measured. Artifacts arising from the SV and SVC on DE pulmonary iodine distribution map were rated on a scale from 1 to 5 (1 = fully diagnostic; 5 = non-diagnostic) by two blinded readers. Results: In protocol 4 mean attenuation in the SV (645 ± 158 HU) and SVC (389 ± 114 HU) were significantly lower compared to groups 1–3 (p < 0.002). Artifacts in group 4 (1.1 ± 0.4 and 1.5 ± 0.7 for the SV and SVC, respectively) were rated significantly less severe compared to group 1 (3.2 ± 1.0 and 3.0 ± 1.1), 2 (2.6 ± 1.1 and 2.3 ± 1.0) and 3 (1.9 ± 0.9 and 1.9 ± 0.7) (p < 0.01 for all), whereas no significant difference was found between groups 1 and 2 for the subclavian vein (p = 0.07). Attenuation in the PA was also significantly lower in group 4 (282 ± 116 HU) compared to group 1 (397 ± 137 HU), group 2 (376 ± 115 HU) and group 3 (311 ± 104 HU), but still on a diagnostic level. Conclusion: Split-bolus injection provides sufficient attenuation for pulmonary DECT

  17. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    International Nuclear Information System (INIS)

    Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min; Rho, Ji Young; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun; White, Charles S.

    2011-01-01

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  18. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hwa Yeon; Song, In Sup (Dept. of Diagnostic Radiology Chung-Ang Univ. College of Medicine, Seoul (Korea, Republic of)); Yoo, Seung Min; Rho, Ji Young (Dept. of Diagnostic Radiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)), email: smyoo68@hanmail.net; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun (Dept. of Cardiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)); White, Charles S. (Dept. of Diagnostic Radiology Univ. of Maryland, Baltimore (United States))

    2011-05-15

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  19. CT coronary angiography: Influence of different cardiac reconstruction intervals on image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: marc.dewey@charite.de; Teige, Florian [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany); Rutsch, Wolfgang [Department of Cardiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: wolfgang.rutsch@charite.de; Schink, Tania [Department of Medical Biometry, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)], E-mail: peter.martus@charite.de; Hamm, Bernd [Department of Radiology, Charite Medical School, Humboldt-Universitaet zu Berlin (Germany)

    2008-07-15

    Purpose: To prospectively analyze image quality and diagnostic accuracy of different reconstruction intervals of coronary angiography using multislice computed tomography (MSCT). Materials and methods: For each of 47 patients, 10 ECG-gated MSCT reconstructions were generated throughout the RR interval from 0 to 90%, resulting in altogether 470 datasets. These datasets were randomly analyzed for image quality and accuracy and compared with conventional angiography. Statistical comparison of intervals was performed using nonparametric analysis for repeated measurements to account for clustering of arteries within patients. Results: Image reconstruction intervals centered at 80, 70, and 40% of the RR interval resulted (in that order) in the best overall image quality for all four main coronary vessels. Eighty percent reconstructions also yielded the highest diagnostic accuracy of all intervals. The combination of the three best intervals (80, 70, and 40%) significantly reduced the nondiagnostic rate as compared with 80% alone (p = 0.005). However, the optimal reconstruction interval combination achieved significantly improved specificities and nondiagnostic rates (p < 0.05). The optimal combination consisted of 1.7 {+-} 0.9 reconstruction intervals on average. In approximately half of the patients (49%, 23/47) a single reconstruction was optimal. In 18 (38%), 3 (6%), and 3 (6%) patients one, two, and three additional reconstruction intervals were required, respectively, to achieve optimal quality. In 28% of the patients the optimal combination consisted of reconstructions other than the three best intervals (80, 70, and 40%). Conclusion: Multiple image reconstruction intervals are essential to ensure high image quality and accuracy of CT coronary angiography.

  20. Dynamics of the aortic annulus in 4D CT angiography for transcatheter aortic valve implantation patients

    NARCIS (Netherlands)

    Elattar, Mustafa A.; Vink, Leon W.; van Mourik, Martijn S.; Baan, Jan; Vanbavel, Ed T.; Planken, R. Nils; Marquering, Henk A.

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) is a well-established treatment for patients with severe aortic valve stenosis. This procedure requires pre-operative planning by assessment of aortic dimensions on CT Angiography (CTA). It is well-known that the aortic root dimensions vary over the

  1. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siebert, E.; Bohner, G. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany); Dewey, M.; Bauknecht, C. [Department of Radiology, Charite Universitary Medicine Berlin (Germany); Klingebiel, R. [Department of Neuroradiology, Charite Universitary Medicine Berlin (Germany)], E-mail: randolf.klingebiel@charite.de

    2010-01-15

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  2. Dose related, comparative evaluation of a novel bone-subtraction algorithm in 64-row cervico-cranial CT angiography

    International Nuclear Information System (INIS)

    Siebert, E.; Bohner, G.; Dewey, M.; Bauknecht, C.; Klingebiel, R.

    2010-01-01

    Purpose: Comparative evaluation of a low-dose scan protocol for a novel bone-subtraction (BS) algorithm, applicable to 64-row cervico-cranial (cc) CT angiography (MSCTA). Methods and patients: BS algorithm assessment was performed in cadaveric phantom studies by stepwise variation of tube current and head malrotation using a 64-row CT scanner. In order to define minimum dose requirements and the rotation correction capacity, a low dose BS MSCTA protocol was defined and evaluated in 12 patients in comparison to a common manual bone removal algorithm. Standard MIPs of both modalities were evaluated in a blinded manner by two neuroradiologists for image quality composed, of vessel contour sharpness and bony vessel superposition, by using a five-point score each. Effective Dose (E) and data post-processing times were defined. Results: In experimental studies prescan tube current could be cut down to one-sixth of post-contrast scan doses without compromise of bone-subtraction whereas incomplete subtraction appeared from four degrees head malrotation on. Prescan E amounted to additional 1.1 mSv (+25%) in clinical studies. BS MSCTA performed significantly superior in terms of bony superposition for vascular segments C3-C7 (p < 0.001), V1-V2, V3-V4 (p < 0.05, p < 0.001 respectively) and the ophthalmic artery (p < 0.05), whereas vessel contour sharpness in BS MSCTA only proved superior for arterial segments V3-V4 (p < 0.001) and C3-C7 (p < 0.001). MBR MSCTA received higher ratings in vessel contour sharpness for C1-C2 (p < 0.001), callosomarginal artery (p < 0.001), M1, M2, M3 (p < 0.001 each) and the basilar artery (p < 0.001). Reconstruction times amounted to an average of 1.5 (BS MSCTA) and 3 min (MBR MSCTA) respectively. Conclusion: The novel BS algorithm provides superior skull base artery visualisation as compared to common manual bone removal algorithms, increasing the Effective Dose by one-fourth. Yet, inferior vessel contour sharpness was noted intracranially, thus

  3. Microsurgical management of cerebral aneurysms based in CT angiography with three-dimensional reconstruction (3D-CTA) and without preoperative cerebral angiography

    International Nuclear Information System (INIS)

    Gonzalez-Darder, J.M.; Pesudo-Martinez, J.V.; Feliu-Tatay, R.A.

    2001-01-01

    Objective. To study the possibilities of the microsurgical management of ruptured intracranial aneurysms with the sole preoperative information provided by computed tomography angiography with three-dimensional reconstruction (3D-CTA). Methods. Patients were studied with 3D-CTA after diagnosis of subarachnoid hemorrhage. If the study had an adequate quality and revealed an aneurysm congruent with the clinical findings or neurological examination and/or with the location of the bleeding on computed tomography (CT) scan an early microsurgical clipping of the lesion was done. When the quality of the 3D-CTA study was not adequate or the quality being adequate displayed no lesions or the findings were not accurate enough to warrant direct microsurgical treatment, the patient was studied with cerebral digital substraction (DS) angiography. A total of 44 consecutive patients harboring a total of 47 intracranial aneurysms diagnosed by 3D-CTA and without preoperative DS angiography were submitted to microsurgical clipping and included in the study. Results. The overall mortality was 15.9 % and the favorable results evaluated 6 months after discharge by means of the Glasgow outcome scale reached 70.4 %. All lesions were successfully clipped. Surgery was done a mean of 4.1 days after the admission bleeding. A total of four microlesions undiagnosed by 3D-CTA were found at surgery and clipped. Postoperative DS angiography and necropsy findings were also used as control of the 3D-CTA findings but no additional information was provided excepting the finding in DS angiography of an asymptomatic intracavemous aneurysm. Therefore the sensitivity of the 3D-CTA for diagnosis of symtomatic aneurysms was 100 % and the overall sensitivity 90.4 %. Conclusions. We have reached similar results in patients operated on with or without preoperative angiography. 3D-CTA provides very valuable anatomical information, which has an additional value in the microsurgical treatment of aneurysms of the

  4. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  5. Three-dimensional CT angiography in the diagnosis of cerebrovascular disease

    International Nuclear Information System (INIS)

    Eguchi, Takahiko; Nikaido, Yuji; Nakamura, Takeshi; Yoneda, Shigeru

    1995-01-01

    We reported the usefulness of three dimensional CT angiography (3 DCTA) in cerebrovascular disease. Twenty two of twenty three intracerebral aneurysms were visualized in 3 DCTA. 3 DTPA was especially useful for the evaluation of posterior-projection anterior communicating arteries and the distinction between a carotid-posterior communicating aneurysm and an infundibular dilatation. An anterior-projection carotid bifurcation aneurysm, which we missed in DSA, was visualized clearly in 3 DCTA. Stenotic cervical carotid artery lesions were well evaluated in 3 DCTA, including ulceration. 3 DCTA was not so useful for evaluation of intracranial artery stenosis. 3 DCTA was useful as a non-invasive method to evaluate cerebrovascular diseases. (author)

  6. Anomalous vessel in the middle ear: the role of CT and MR angiography

    International Nuclear Information System (INIS)

    Caldas, J.G.M.P.; Iffenecker, C.; Lasjaunias, P.; Doyon, D.; Attal, P.

    1998-01-01

    An 8-year-old child was examined because of conductive hearing loss with a retrotympanic mass on otoscopy. CT and MR angiography showed a large inferior tympanic artery traversing the hypotympanum and joining a thin, irregular internal carotid artery with a normal middle meningeal artery. These investigations, coupled with knowledge of the embryological development allowed a diagnosis of a complex vascular anomaly in the middle ear and avoided potential surgical complications. (orig.)

  7. Assessment of the usefulness of three-dimensional CT angiography after peripheral arterial bypass surgery

    International Nuclear Information System (INIS)

    Hayashi, Saihou; Sasaki, Masaru; Kawamoto, Jun

    1997-01-01

    Conventional CT and three-dimensional CT angiography (3D-CTA) were conducted after peripheral arterial bypass surgery on 17 patients (26 grafts) from October, 1994 to April, 1996. Seventeen grafts were patent. The following objectives were satisfied in these cases: 1. Prosthetic graft or saphenous vein was depicted by 3D-CTA, 2. The distal portion of the native artery was depicted by 3D-CTA, and 3. Opacification of the graft interior was recognized by transverse section of CT. Nine grafts were occluded but prosthetic grafts were depicted in 5 cases, and prosthetic grafts and the distal portions of native arteries in 3 cases. Opacification of the graft interior was not seen in any case. Achievement of the above three objectives was considered necessary to determine graft patency. (author)

  8. Variability and accuracy of coronary CT angiography including use of iterative reconstruction algorithms for plaque burden assessment as compared with intravascular ultrasound - an ex vivo study

    Energy Technology Data Exchange (ETDEWEB)

    Stolzmann, Paul [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Schlett, Christopher L.; Maurovich-Horvat, Pal; Scheffel, Hans; Engel, Leif-Christopher; Karolyi, Mihaly; Hoffmann, Udo [Massachusetts General Hospital and Harvard Medical School, Cardiac MR PET CT Program, Boston, MA (United States); Maehara, Akiko; Ma, Shixin; Mintz, Gary S. [Columbia University Medical Center, Cardiovascular Research Foundation, New York, NY (United States)

    2012-10-15

    To systematically assess inter-technique and inter-/intra-reader variability of coronary CT angiography (CTA) to measure plaque burden compared with intravascular ultrasound (IVUS) and to determine whether iterative reconstruction algorithms affect variability. IVUS and CTA data were acquired from nine human coronary arteries ex vivo. CT images were reconstructed using filtered back projection (FBPR) and iterative reconstruction algorithms: adaptive-statistical (ASIR) and model-based (MBIR). After co-registration of 284 cross-sections between IVUS and CTA, two readers manually delineated the cross-sectional plaque area in all images presented in random order. Average plaque burden by IVUS was 63.7 {+-} 10.7% and correlated significantly with all CTA measurements (r = 0.45-0.52; P < 0.001), while CTA overestimated the burden by 10 {+-} 10%. There were no significant differences among FBPR, ASIR and MBIR (P > 0.05). Increased overestimation was associated with smaller plaques, eccentricity and calcification (P < 0.001). Reproducibility of plaque burden by CTA and IVUS datasets was excellent with a low mean intra-/inter-reader variability of <1/<4% for CTA and <0.5/<1% for IVUS respectively (P < 0.05) with no significant difference between CT reconstruction algorithms (P > 0.05). In ex vivo coronary arteries, plaque burden by coronary CTA had extremely low inter-/intra-reader variability and correlated significantly with IVUS measurements. Accuracy as well as reader reliability were independent of CT image reconstruction algorithm. (orig.)

  9. Prostatic arterial supply: demonstration by multirow detector Angio CT and Catheter Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Bilhim, Tiago [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Pisco, Joao M. [Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Universidade Nova de Lisboa, Departamento Universitario de Radiologia, Faculdade de Ciencias Medicas, Lisbon (Portugal); Furtado, Andrea; Casal, Diogo; Pais, Diogo; O' Neill, Joao E.G. [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Campos Pinheiro, Luis [Universidade Nova de Lisboa, Departamento Universitario de Urologia, Faculdade de Ciencias Medicas, Lisbon (Portugal)

    2011-05-15

    To evaluate the prostatic arterial supply with multidetector Angio CT and Digital Subtraction Angiography (DSA). DSA was performed in 21 male patients (7 of these also underwent Pelvic Angio CT); a further 4 patients only underwent Angio CT. Prostatic arteries were classified according to their origin, direction, number of pedicles, termination and anastomoses with surrounding arteries in 50 pelvic sides. The most frequent origin was the internal pudendal artery (n = 28; 56%) with the common gluteal-pudendal trunk the next commonest (n = 14; 28%). Less frequent origins were the obturator artery (n = 6; 12%) or the inferior gluteal artery (n = 2; 4%). Two separate vascular pedicles were found in 12 pelvic sides (24%). There were anastomoses with the termination of the internal pudendal artery in 24% of cases (n = 12), with the contra-lateral prostatic arteries in 6 cases (12%), and to the superior vesical artery in 4 cases (8%). Defining prostatic artery origin and direction is paramount to allow selective catheterisation. Angio CT is very useful as a pre-intervention tool. The number of independent vascular pedicles and the presence of anastomoses with surrounding arteries should be taken into account when planning prostatic arterial embolisation. (orig.)

  10. Prostatic arterial supply: demonstration by multirow detector Angio CT and Catheter Angiography

    International Nuclear Information System (INIS)

    Bilhim, Tiago; Pisco, Joao M.; Furtado, Andrea; Casal, Diogo; Pais, Diogo; O'Neill, Joao E.G.; Campos Pinheiro, Luis

    2011-01-01

    To evaluate the prostatic arterial supply with multidetector Angio CT and Digital Subtraction Angiography (DSA). DSA was performed in 21 male patients (7 of these also underwent Pelvic Angio CT); a further 4 patients only underwent Angio CT. Prostatic arteries were classified according to their origin, direction, number of pedicles, termination and anastomoses with surrounding arteries in 50 pelvic sides. The most frequent origin was the internal pudendal artery (n = 28; 56%) with the common gluteal-pudendal trunk the next commonest (n = 14; 28%). Less frequent origins were the obturator artery (n = 6; 12%) or the inferior gluteal artery (n = 2; 4%). Two separate vascular pedicles were found in 12 pelvic sides (24%). There were anastomoses with the termination of the internal pudendal artery in 24% of cases (n = 12), with the contra-lateral prostatic arteries in 6 cases (12%), and to the superior vesical artery in 4 cases (8%). Defining prostatic artery origin and direction is paramount to allow selective catheterisation. Angio CT is very useful as a pre-intervention tool. The number of independent vascular pedicles and the presence of anastomoses with surrounding arteries should be taken into account when planning prostatic arterial embolisation. (orig.)

  11. Multi-slice spiral CT coronary angiography: influence of heart rate and reconstruction window on image quality

    International Nuclear Information System (INIS)

    Mao Dingbiao; Hua Yanqing; Wang Mingpeng; Zhang Guozhen; Wu Weilan; Hu Fei; Ge Xiaojun; Ding Qiyong

    2004-01-01

    Objective: To evaluate the influence of heart rate and reconstruction window on image quality of multi-slice spiral CT coronary angiography. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 80 healthy cases. Results: Four coronary (RCA, LM, LAD, LCX) segments were analyzed in each patient with regard to image quality. 82.1% (46/56) of the coronary segments were sufficient for analysis in patients with heart rate ≤60 bpm, 63.4% (104/164) with 61-70 bpm, 41.2%(28/68) with 71-80 bpm, and 31.2%(10/32) with>80 bpm, respectively. The left anterior descending artery, left circumflex artery, and the right coronary artery were best visualized when the reconstruction window was 60%-70%, 50%-60%, and 50%-70%, respectively. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate and reconstruction window

  12. Detection of coronary artery calcification by ultrafast CT and correlation with angiography

    International Nuclear Information System (INIS)

    Zhang Shaoxiong; Dai Ruping; Lu Bin

    1997-01-01

    To investigate the relationship between coronary calcification and significant coronary stenosis ninety patients including 81 men and 9 women were studied asithage ranging from 27∼72 years (mean, 58 years). All patients had both ultrafast CT (UFCT) examination and coronary angiography within one month. Single slice mode with ECG gating and thickness of 3 mm were used in UFCT scan. Selected coronary angiography was performed by the Judkins technique. Among 160 vessels in which coronary calcifications were identified, 74% had significant coronary stenosis (>50% stenosis), and 77% of 154 vessels with significant coronary stenosis had calcification demonstrable by UFCT. In the younger age group the sensitivity of calcification for evaluating stenosis of coronary artery was lower and the specificity was generally higher than those in the elderly group. UFCT is a promising procedure for detecting coronary arterial disease, since this examination has high sensitivity and specificity, easy to conduct, noninvasive, and widely applicable for screening a large population

  13. Clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease

    International Nuclear Information System (INIS)

    Tian Xinhua; Liu Jianhua; Gong Tingting; Geng Lili; Sun Yong

    2011-01-01

    Objective: To investigate the clinical application of ECG-gated 256-slice CT angiography for diagnosis of congenital heart disease, and to evaluate the relationship of the image quality and radiation dose between prospective ECG-gated and retrospective ECG-gated cardiac CT angiography (CTA). Methods: Sixty patients who doubt congenital heart disease underwent cardiac CTA, and they were randomly divided into two groups. Thirty patients in group A underwent prospective ECG-gated cardiac CTA, and thirty patients in group B underwent retrospective ECG-gated cardiac CTA. Then the homogeneous enhancement of vascular structures, stair-step artifact, overall image quality and radiation dose were evaluated. Results: The homogeneous enhancement of vascular structures were 2.8±0.3 and 2.7±0.6, respectively, in two groups; and there was no statistical significance (P>0.05). The stair-step artifact were 3.0±0.9 and 3.1±0.9, respectively, in two groups; and there was also no statistical significance (P>0.05). The overall image quality were 3.0±0.8 and 3.1±0.9, respectively, in two group; and there was statistical significance (P>0.05). However, the effective dose were (5.24±0.52) mSv and (16.68±1.49) mSv, respectively, in two groups; and there was statistical significance (P<0.001). Conclusion: Compared with retrospective ECG-gated cardiac CTA, prospective ECG-gated cardiac CTA can reduce radiation dose about 68.6% , while maintaining the image quality which could be made diagnosis. (authors)

  14. Studies on intracranial collateral circulation with multi-slice CT angiography in patients with symptomatic cerebral artery stenosis

    Directory of Open Access Journals (Sweden)

    Shu-qing ZHOU

    2011-06-01

    Full Text Available Objective To explore the features of intracranial collateral circulation in patients with symptomatic cerebral artery stenosis.Method Ninety-four patients with ischemic cerebrovascular disease admitted from Apr.2004 to Jun.2009 were involved in present study.All the patients were examined with cerebral multi-slice CT angiography,and the features of cerebral artery stenosis and intracranial collateral circulation were evaluated using maximum intensity projection(MIP and volume rendering(VR images of CT angiography.Result Of the 94 patients involved,48 were diagnosed as cerebral artery stenosis,including 29 cases of cerebral infarction,18 of transient ischemic attack(TIA and 1 of moyamoya disease(MMD.Among the 14 cases of severe cerebral artery stenosis or occlusion,cerebral infarction was found in 6 cases with lesser intracranial collateral vessels(including massive cerebral infarction in 4 cases and watershed infarction in 2 cases,and focal infarction of central semi-ovale in 1 case and TIA in 7 cases were found with abundant intracranial collateral vessels.Multiple lacunar infarction was found in 22 cases of mild or moderate cerebral artery stenosis,but there was no significant correlation between the stenosed arteries and infarction sites.Abundant intracranial collateral vessels were found in one patient with Moyamoya disease but no infarction was observed.Conclusions Intracranial collateral circulation plays an important role of compensation in patients with severe cerebral artery stenosis or occlusion.Cerebral angiography with multi-slice CT is of great significance in evaluation of cerebral artery stenosis and intracranial collateral circulation.

  15. Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Fan, Zhanming; Yu, Wei; Lv, Biao; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China)

    2011-05-15

    To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant ({>=}50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar's test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 {+-} 4.7 mSv. 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF. (orig.)

  16. Three-dimensional anatomical evaluation of bronchial artery with CT angiography

    International Nuclear Information System (INIS)

    Yu Hong; Li Huimin; Xiao Xiangsheng; Liu Shiyuan; Li Chengzhou; Tao Xiaofeng

    2006-01-01

    Objective: To evaluate the ability of CT angiography in identifying and demonstrating the origins and courses of bronchial arteries by using the three-dimensional reformation technique. Methods Four hundred and forty-three eases were examined with thin-section enhanced MSCT. Three-dimensional images of bronchial arteries were processed at the workstation. Spatial anatomical characters of the bronchial arteries using volume rendering(VR), muhiplanar reconstruction (MPR), and maxium intensity projection (MIP) were observed. Results: At least one bronchial artery was clearly displayed in VR in 359 eases. The right bronchial arteries mainly appeared to originate from the right intercostal artery (213/436, 48.85% ) and descending aorta (207/436, 47.48%), while the left bronchial arteries mainly from the descending aorta (363/371, 97.84%). The right bronchial arteries of the descending aorta were mainly arised from fight wall (95/207, 45.89%), and then the anterior wall (88/207, 42.51%), while the left bronchial arteries of the descending aorta mainly arised from anterior wall of the aorta (272/363, 74.93%). The common trunk originated from the descending aorta mainly positioned in the anterior wall (57/77, 74.03%). 49.31% (215/436) of the fight bronchial arteries were coursing across the posterior edge of the right main bronchi, 35.55% (155/436) coursing the inferior edge, while 60.11% (223/371) of left bronchial arteries coursing forward across the superior edger of the left main bronchi, the others coursing the inferior or the posterior edge. There were eleven bronchial artery distribution patterns, with the right and left ones predominating (192/359, 53.48%), and then two right and one left (63/359, 17.55%). Conclusion: The bronchial artery anatomy was complicated, and CT angiography could clearly visualize the features. (authors)

  17. CT angiography and CT perfusion improve prediction of infarct volume in patients with anterior circulation stroke

    Energy Technology Data Exchange (ETDEWEB)

    Seeters, Tom van; Schaaf, Irene C. van der; Dankbaar, Jan Willem; Horsch, Alexander D.; Niesten, Joris M.; Luitse, Merel J.A.; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, Geert Jan; Kappelle, L.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Vos, Jan Albert [St. Antonius Hospital, Department of Radiology, Nieuwegein (Netherlands); Schonewille, Wouter J. [St. Antonius Hospital, Department of Neurology, Nieuwegein (Netherlands); Walderveen, Marianne A.A. van [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Wermer, Marieke J.H. [Leiden University Medical Center, Department of Neurology, Leiden (Netherlands); Duijm, Lucien E.M. [Catharina Hospital, Department of Radiology, Eindhoven (Netherlands); Keizer, Koos [Catharina Hospital, Department of Neurology, Eindhoven (Netherlands); Bot, Joseph C.J. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Visser, Marieke C. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Lugt, Aad van der [Erasmus MC University Medical Center, Department of Radiology, Rotterdam (Netherlands); Dippel, Diederik W.J. [Erasmus MC University Medical Center, Department of Neurology, Rotterdam (Netherlands); Kesselring, F.O.H.W. [Rijnstate Hospital, Department of Radiology, Arnhem (Netherlands); Hofmeijer, Jeannette [Rijnstate Hospital, Department of Neurology, Arnhem (Netherlands); Lycklama a Nijeholt, Geert J. [Medical Center Haaglanden, Department of Radiology, The Hague (Netherlands); Boiten, Jelis [Medical Center Haaglanden, Department of Neurology, The Hague (Netherlands); Rooij, Willem Jan van [St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Kort, Paul L.M. de [St. Elisabeth Hospital, Department of Neurology, Tilburg (Netherlands); Roos, Yvo B.W.E.M. [Academic Medical Center, Department of Neurology, Amsterdam (Netherlands); Meijer, Frederick J.A. [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Pleiter, C.C. [St. Franciscus Hospital, Department of Radiology, Rotterdam (Netherlands); Graaf, Yolanda van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Collaboration: Dutch acute stroke study (DUST) investigators

    2016-04-15

    We investigated whether baseline CT angiography (CTA) and CT perfusion (CTP) in acute ischemic stroke could improve prediction of infarct presence and infarct volume on follow-up imaging. We analyzed 906 patients with suspected anterior circulation stroke from the prospective multicenter Dutch acute stroke study (DUST). All patients underwent baseline non-contrast CT, CTA, and CTP and follow-up non-contrast CT/MRI after 3 days. Multivariable regression models were developed including patient characteristics and non-contrast CT, and subsequently, CTA and CTP measures were added. The increase in area under the curve (AUC) and R{sup 2} was assessed to determine the additional value of CTA and CTP. At follow-up, 612 patients (67.5 %) had a detectable infarct on CT/MRI; median infarct volume was 14.8 mL (interquartile range (IQR) 2.8-69.6). Regarding infarct presence, the AUC of 0.82 (95 % confidence interval (CI) 0.79-0.85) for patient characteristics and non-contrast CT was improved with addition of CTA measures (AUC 0.85 (95 % CI 0.82-0.87); p < 0.001) and was even higher after addition of CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001) and combined CTA/CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001). For infarct volume, adding combined CTA/CTP measures (R{sup 2} = 0.58) was superior to patient characteristics and non-contrast CT alone (R{sup 2} = 0.44) and to addition of CTA alone (R{sup 2} = 0.55) or CTP alone (R{sup 2} = 0.54; all p < 0.001). In the acute stage, CTA and CTP have additional value over patient characteristics and non-contrast CT for predicting infarct presence and infarct volume on follow-up imaging. These findings could be applied for patient selection in future trials on ischemic stroke treatment. (orig.)

  18. [Giant aneurysm of posterior comunicating artery (PCoA) in cerebral panarteriography and CT angiography (CTA)].

    Science.gov (United States)

    Jaźwiec, Przemysław; Chwiszczuk, Luiza; Sasiadek, Marek; Całka, Karol; Kuniej, Tomasz; Plucińska, Irena

    2008-01-01

    We present a case of 32-year-old woman, who was admitted to the Department of Neurology in the emergency mode, due to: instantaneous pupillary dilation (mydriasis), ptosis of the left eyeball and double vision. We performed plain CT, panarteriography of cerebral vessels, CT angiography with RT3D (volume-rendered three-dimensional) reconstruction images. On the base of imaging studies the diagnosis of giant saccular aneurysm of the left posterior communicating artery was established. The patient was operated on and the giant aneurysm of left posterior communicating artery was clipped, confirming radiological diagnosis. During operation and postoperative period no complications were noted.

  19. Flat-panel detector volumetric CT for visualization of subarachnoid hemorrhage and ventricles: preliminary results compared to conventional CT

    International Nuclear Information System (INIS)

    Doelken, M.; Struffert, T.; Richter, G.; Engelhorn, T.; Doerfler, A.; Nimsky, C.; Ganslandt, O.; Hammen, T.

    2008-01-01

    The aim of this study was to compare flat-panel volumetric CT (VCT) to conventional CT (cCT) in the visualization of the extent of subarachnoid hemorrhage (SAH) and the width of the ventricles in patients with acute SAH. Included in the study were 22 patients with an acutely ruptured cerebral aneurysm who received VCT during coil embolization. VCT image quality, the extent of SAH (using a modified Fisher score and total slice number with SAH visible) and the width of the ventricles (Evans index) were evaluated by two experienced neuroradiologists (RAD1 and RAD2) and compared to the findings on cCT. Ten patients undergoing VCT for reasons other than SAH served as negative controls. Interobserver agreement in rating image quality was excellent for cCT (Kendall W value 0.94) and good for VCT (0.74). SAH was identified by RAD1 and RAD2 on VCT images in all patients. The modified Fisher scores underestimated the extent of SAH on VCT images in comparison with cCT images. Pearson's correlation coefficient (r) regarding the number of image slices with SAH visible on cCT images compared with the number on VCT images was 0.85 for RAD1 and 0.84 for RAD2. The r value for the degree of interobserver agreement for the number of slices with SAH visible was 0.99 for cCT, and 0.95 for VCT images (n 19), respectively. The width of the ventricles measured in terms of the Evans Index showed excellent concordance between the modalities (r = 0.81 vs. 0.82). Our preliminary results indicate that VCT is helpful in evaluating SAH in the angiography suite. Additionally, reliable evaluation of ventricle width is feasible. However, there are limitations with regard to the visibility of SAH on VCT images in comparison to cCT images. (orig.)

  20. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    International Nuclear Information System (INIS)

    Dewey, Marc; Teige, Florian; Hamm, Bernd; Laule, Michael

    2007-01-01

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p 74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  1. Axial CT of the brain compared with other clinical methods of examination in neuropaediatry

    International Nuclear Information System (INIS)

    Miller, E.

    1979-01-01

    CT of the neurocranium and EEC were carried out in 53 children aged 10 weeks to 15.5 years. In most of the children, also plain-film X-rays of the skull, echoencephalography, scintiscans of the brain, cerebral angiography and, in a few cases, pneumoencephalography were carried out. The methods of examination were comparatively evaluated for neoplastic, inflammatory, congenital and degenerative diseases and cerebral attacks. (APR) [de

  2. 18F-FDG-PET/CT Angiography for the Diagnosis of Infective Endocarditis.

    Science.gov (United States)

    Roque, A; Pizzi, M N; Cuéllar-Calàbria, H; Aguadé-Bruix, S

    2017-02-01

    This article reviews the current imaging role of 18 F-fluordeoxyglucose positron emission computed tomography ( 18 F-FDG-PET/CT) combined with cardiac CT angiography (CTA) in infective endocarditis and discusses the strengths and limitations of this technique. The diagnosis of infective endocarditis affecting prosthetic valves and intracardiac devices is challenging because echocardiography and, therefore, the modified Duke criteria have well-recognized limitations in this clinical scenario. The high sensitivity of 18 F-FDG-PET/CT for the detection of infection associated with the accurate definition of structural damage by gated cardiac CTA in a combined technique (PET/CTA) has provided a significant increase in diagnostic sensitivity for the detection of IE. PET/CTA has proven to be a useful diagnostic tool in patients with suspected infective endocarditis. The additional information provided by this technique improves diagnostic performance in prosthetic valve endocarditis when it is used in combination with the Duke criteria. The findings obtained in PET/CTA studies have been included as a major criterion in the recently updated diagnostic algorithm in infective endocarditis guidelines.

  3. Early detection of lung cancer using ultra-low-dose computed tomography in coronary CT angiography scans among patients with suspected coronary heart disease.

    Science.gov (United States)

    Zanon, Matheus; Pacini, Gabriel Sartori; de Souza, Vinicius Valério Silveiro; Marchiori, Edson; Meirelles, Gustavo Souza Portes; Szarf, Gilberto; Torres, Felipe Soares; Hochhegger, Bruno

    2017-12-01

    To assess whether an additional chest ultra-low-dose CT scan to the coronary CT angiography protocol can be used for lung cancer screening among patients with suspected coronary artery disease. 175 patients underwent coronary CT angiography for assessment of coronary artery disease, additionally undergoing ultra-low-dose CT screening to early diagnosis of lung cancer in the same scanner (80kVp and 15mAs). Patients presenting pulmonary nodules were followed-up for two years, repeating low-dose CTs in intervals of 3, 6, or 12 months based on nodule size and growth rate in accordance with National Comprehensive Cancer Network guidelines. Ultra-low-dose CT identified 71 patients with solitary pulmonary nodules (41%), with a mean diameter of 5.50±4.00mm. Twenty-eight were >6mm, and in 79% (n=22) of these cases they were false positive findings, further confirmed by follow-up (n=20), resection (n=1), or biopsy (n=1). Lung cancer was detected in six patients due to CT screening (diagnostic yield: 3%). Among these, four cases could not be detected in the cardiac field of view. Most patients were in early stages of the disease. Two patients diagnosed at advanced stages died due to cancer complications. The addition of the ultra-low-dose CT scan represented a radiation dose increment of 1.22±0.53% (effective dose, 0.11±0.03mSv). Lung cancer might be detected using additional ultra-low-dose protocols in coronary CT angiography scans among patients with suspected coronary artery disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Schabel, C.; Bongers, M.N.; Syha, R.; Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F.; Thomas, C.

    2015-01-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [de

  5. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siablis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece)]. E-mail: siablis@med.upatras.gr; Kagadis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karamessini, Maria T. [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Konstantinou, Dimitrios [Department of Neurosurgery, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Petsas, Theodore [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Nikiforidis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece)

    2005-07-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.

  6. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Kagadis, George C.; Karamessini, Maria T.; Konstantinou, Dimitrios; Karnabatidis, Dimitrios; Petsas, Theodore; Nikiforidis, George C.

    2005-01-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms

  7. Dual energy CT intracranial angiography: image quality, radiation dose and initial application results

    International Nuclear Information System (INIS)

    Chai Xue; Zhang Longjiang; Lu Guangming; Zhou Changsheng

    2009-01-01

    Objective: To assess the clinical value of dual-energy intracranial CT angiography (CTA). Methods: Forty-one patients suspected of intracranial vascular diseases underwent dual-energy intracranial CT angiography, and 41 patients who underwent conventional subtraction CT were enrolled as the control group. Image quality of intracranial and skull base vessels and radiation dose between dual-energy CTA and conventional subtraction CTA were compared using two independent sample nonparametric test and independent-samples t test, respectively. Prevalence and size of lesions detected by dual-energy CTA and digital subtraction CTA were compared using paired-samples t test and Spearman correlative analysis. Results: The percentage of image quality scored 5 was 70.7% (29/41) for dual-energy CTA and 75.6% (31/41) for conventional subtraction CTA. There was no significant difference between the two groups (Z= -0.455, P=0.650). Image quality of vessels at the skull base in conventional subtraction CTA was superior to that in dual-energy CTA, especially for the petrosal and syphon segment (Z=-4.087, P=0.000). Radiation exposure of dual energy CTA and conventional CTA were (396.54±17.43) and (1090.95±114.29) mGy·cm respectively. Radiation exposure was decreased by 64% (t=-38.52, P=0.000) by dual energy CTA compared with conventional subtraction CTA. Out of the 41 patients, 19 patients were diagnosed as intracranial aneurysm, 2 patients as arteriovenous malformation (AVM), 3 patients with Moya-moya's disease, and the remaining 17 patients with negative results. Nine patients with intracranial aneurysm, 2 patients with AVM, 3 patients with Moya-moya's disease, and 2 patients with negative findings underwent DSA or operation, with concordant findings from both techniques. Diameter of aneurysm neck, long axis and minor axis by dual-energy CTA was (2.90±1.61), (5.23±1.68) and (3.83±1.69) mm, respectively; Diameter of aneurysm neck, long axis and minor axis by DSA was (2.95±1

  8. Clinical evaluation of dual-energy bone removal in CT angiography of the head and neck: comparison with conventional bone-subtraction CT angiography

    International Nuclear Information System (INIS)

    Deng, K.; Liu, C.; Ma, R.; Sun, C.; Wang, X.-M.; Ma, Z.-T.; Sun, X.-L.

    2009-01-01

    Aim: To evaluate the bone-subtraction effect of dual-energy bone removal in computed tomography angiography (CTA) of the head and neck in comparison with conventional bone-subtraction CTA. Material and Methods: The study comprised 52 patients who were divided into two groups at random, and examined using dual-source CT for head and neck CTA. Dual-energy bone removal CTA and conventional bone-subtraction CTA were applied to each of the two groups, respectively. The bone subtraction was performed automatically in both methods. Vascular structures, as well as brain tissue remained visible. The subtracted images were further processed with maximum intensity projection (MIP) and volume-rendering technique (VRT) for image evaluation. Two experienced radiologists reviewed the resulting subtracted and non-subtracted volume data with respect to the delineation and detection of image quality and vascular pathology. Results: The means of the weighted CT dose index (CTDIvol) for bone-removal dual-energy CTA and conventional bone-subtraction CTA were 20.56 ± 0.01 mGy and 25.57 ± 0.56 mGy, respectively. There was a significant difference between them. The percentage of carotid and vertebral arteries and all other vessels that could be successfully assessed with these two methods were 87.8, 68, and 83%, and 93.5, 91.8, and 92.6%, respectively. There were no significant differences in the visualization of the carotid arteries; however, there were significant differences in the visualization of the vertebral arteries. Conclusion: Compared with conventional bone-subtraction CTA, dual-energy bone-removal CTA had a lower radiation dose. It eliminated most bones in the head and neck successfully; however, the bone subtraction effect around the vertebral artery was unsatisfactory. Dual-energy bone-removal CTA provides a new method for detecting vascular diseases in routine clinical work.

  9. Quality of CT pulmonary angiography for suspected pulmonary embolus in pregnancy

    International Nuclear Information System (INIS)

    U-King-Im, Jean Marie; Freeman, Susan J.; Boylan, Teresa; Cheow, Heok K.

    2008-01-01

    The main objective of this study was to assess the quality of CT pulmonary angiography (CTPA) for suspected pulmonary embolus (PE) in the pregnant population. We retrospectively identified 40 consecutive pregnant patients who underwent CTPA from January 2005 to December 2006. Forty consecutive age-matched non-pregnant women were used as a control group. Studies were subjectively graded according to overall image quality by two readers in consensus, in randomised and blinded manner. Moreover, contrast enhancement of pulmonary arteries was subjectively and objectively evaluated. The proportion of sub-optimal studies was more than three times higher in the pregnant group (27.5%, n = 11) compared with the non-pregnant group (7.5%, n = 3; p = 0.015). Mean contrast enhancement was consistently higher in the non-pregnant group compared with pregnant group, both subjectively and objectively. The percentage of inadequately opacified vascular segments was more than two times higher in the pregnant group (28.7%, n = 264) than in the non-pregnant group (13.3%, n 122; p = 0.0001). The incidence of sub-optimal CTPA studies is higher in pregnancy when compared with an age-matched non-pregnant control group. In addition to radiation issues, this should also be considered when implementing diagnostic strategies for suspected PE in pregnancy. (orig.)

  10. Hybrid ECG-gated versus non-gated 512-slice CT angiography of the aorta and coronary artery: image quality and effect of a motion correction algorithm.

    Science.gov (United States)

    Lee, Ji Won; Kim, Chang Won; Lee, Geewon; Lee, Han Cheol; Kim, Sang-Pil; Choi, Bum Sung; Jeong, Yeon Joo

    2018-02-01

    Background Using the hybrid electrocardiogram (ECG)-gated computed tomography (CT) technique, assessment of entire aorta, coronary arteries, and aortic valve can be possible using single-bolus contrast administration within a single acquisition. Purpose To compare the image quality of hybrid ECG-gated and non-gated CT angiography of the aorta and evaluate the effect of a motion correction algorithm (MCA) on coronary artery image quality in a hybrid ECG-gated aorta CT group. Material and Methods In total, 104 patients (76 men; mean age = 65.8 years) prospectively randomized into two groups (Group 1 = hybrid ECG-gated CT; Group 2 = non-gated CT) underwent wide-detector array aorta CT. Image quality, assessed using a four-point scale, was compared between the groups. Coronary artery image quality was compared between the conventional reconstruction and motion correction reconstruction subgroups in Group 1. Results Group 1 showed significant advantages over Group 2 in aortic wall, cardiac chamber, aortic valve, coronary ostia, and main coronary arteries image quality (all P ECG-gated CT significantly improved the heart and aortic wall image quality and the MCA can further improve the image quality and interpretability of coronary arteries.

  11. Intracranial CT angiography obtained from a cerebral CT perfusion examination

    International Nuclear Information System (INIS)

    Gratama van Andel, H. A. F.; Venema, H. W.; Majoie, C. B.; Den Heeten, G. J.; Grimbergen, C. A.; Streekstra, G. J.

    2009-01-01

    CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging

  12. The value of standard radiology, angiography and computed tomography for the diagnosis of primary and secondary bone tumors

    International Nuclear Information System (INIS)

    Wagner, R.

    1986-01-01

    The diagnostic value of X-ray images, angiography and computed tomography (CT) was compared using 45 benign, semi-malignant and malignant bone tumors. All around, computed tomography proved to be more accurate than angiography. CT is therefore recommended for use as the first non-invasive examination method after X-ray images have been made. (MBC) [de

  13. Diagnostic value of quantitative stenosis predictors with coronary CT angiography compared to invasive fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Renker, Matthias [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Kerckhoff Heart and Thorax Center, Benekestrasse 2-8, 61231 Bad Nauheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Wichmann, Julian L. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Fuller, Stephen R.; Rier, Jeremy D.; Bayer, Richard R.; Steinberg, Daniel H. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); De Cecco, Carlo N. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Departments of Radiological Sciences, Oncology, and Pathology, University of Rome “Sapienza”-Polo Pontino, Latina, Viale Regina Elena, 324-00161 Roma (Italy); Baumann, Stefan [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); First Department of Medicine, University Medical Centre Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2015-08-15

    Highlights: • Evaluation of the diagnostic performance of CCTA predictors for coronary stenosis. • TAG was unable to detect hemodynamically significant coronary lesions. • CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA. • CT-FFR was the best parameter. - Abstract: Objective: To evaluate the diagnostic performance of CCTA-derived stenosis predictors including CT-FFR for the detection of ischemia-inducing stenosis compared to invasive FFR. Materials and methods: Stenosis parameters were assessed using dual-source CT (DSCT). All patients underwent both CCTA and invasive FFR within 3 months and were retrospectively analyzed. Observers visually assessed all CCTA studies and performed multiple lesion measurements. Lesion length/minimal luminal diameter{sup 4} (LL/MLD{sup 4}), transluminal attenuation gradient (TAG), corrected coronary attenuation (CCO) and CT-FFR were calculated. Results: The cohort included 32 patients (58 ± 12 years, 66%male). Among 32 coronary lesions, 8 (25%) were considered hemodynamically significant with an FFR <0.80. Compared to invasive FFR, the per-vessel sensitivity and specificity of CCTA, CT-FFR, LL/MLD{sup 4}, CCO and TAG for detecting hemodynamically significant lesions were 100% and 54%, 100% and 91%, 85% and 92%, 66% and 88%, 37% and 58%, respectively. Receiver operating characteristics analysis resulted in an area under the curve of 0.91 for CT-FFR (p = 0.0005), 0.88 for LL/MLD{sup 4} (p < 0.0001), 0.85 for CCO (p < 0.0001). TAG with an AUC of 0.67 (p = 0.152) was unable to discriminate between vessels with or without hemodynamically significant lesions. Conclusion: CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA analysis alone for discrimination of hemodynamically significant coronary stenosis.

  14. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  15. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  16. Structured Head and Neck CT Angiography Reporting Reduces Resident Revision Rates.

    Science.gov (United States)

    Johnson, Tucker F; Brinjikji, Waleed; Doolittle, Derrick A; Nagelschneider, Alex A; Welch, Brian T; Kotsenas, Amy L

    2018-04-12

    This resident-driven quality improvement project was undertaken to assess the effectiveness of structured reporting to reduce revision rates for afterhours reports dictated by residents. The first part of the study assessed baseline revision rates for head and neck CT angiography (CTA) examinations dictated by residents during afterhours call. A structured report was subsequently created based on templates on the RSNA informatics reporting website and critical findings that should be assessed for on all CTA examinations. The template was made available to residents through the speech recognition software for all head and neck CTA examinations for a duration of 2 months. Report revision rates were then compared with and without use of the structured template. The structured template was found to reduce revision rates by approximately 50% with 10/41 unstructured reports revised and 2/17 structured reports revised. We believe that structured reporting can help reduce reporting errors, particularly in term of typographical errors, train residents to evaluate complex examinations in a systematic fashion, and assist them in recalling critical findings on these examinations. Copyright © 2018 Elsevier Inc. All rights reserved.

  17. Noninvasive FFR derived from coronary CT angiography in the management of coronary artery disease: technology and clinical update

    Directory of Open Access Journals (Sweden)

    Nakanishi R

    2016-06-01

    Full Text Available Rine Nakanishi, Mathew J Budoff Los Angeles Biomedical Research Institute, Harbor-UCLA Medical Center, Torrance, CA, USA Abstract: After a decade of clinical use of coronary computed tomographic angiography (CCTA to evaluate the anatomic severity of coronary artery disease, new methods of deriving functional information from CCTA have been developed. These methods utilize the anatomic information provided by CCTA in conjunction with computational fluid dynamics to calculate fractional flow reserve (FFR values from CCTA image data sets. Computed tomography-derived FFR (CT-FFR enables the identification of lesion-specific drop noninvasively. A three-dimensional CT-FFR modeling technique, which provides FFR values throughout the coronary tree (HeartFlow FFRCT analysis, has been validated against measured FFR and is now approved by the US Food and Drug Administration for clinical use. This technique requires off-site supercomputer analysis. More recently, a one-dimensional computational analysis technique (Siemens cFFR, which can be performed on on-site workstations, has been developed and is currently under investigation. This article reviews CT-FFR technology and clinical evidence for its use in stable patients with suspected coronary artery disease. Keywords: fractional flow reserve, coronary computed tomographic angiography, FFRCT, cFFR

  18. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    International Nuclear Information System (INIS)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva; Elsner, Andreas; Bolte, Matthias; Domik, Gitta; Hoff, Joerg van den

    2009-01-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  19. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    International Nuclear Information System (INIS)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R.; Grude, M.

    2003-01-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 ± 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  20. Quantification of coronary artery calcium on the basis of dual-energy coronary CT angiography.

    Science.gov (United States)

    Schwarz, Florian; Nance, John W; Ruzsics, Balazs; Bastarrika, Gorka; Sterzik, Alexander; Schoepf, U Joseph

    2012-09-01

    To evaluate the feasibility of using virtual noncontrast material-enhanced (VNC) computed tomographic (CT) series derived from dual-energy CT imaging studies for coronary artery calcium quantification. This HIPAA-compliant study was institutional review board approved; all patients provided written informed consent. Thirty-six patients prospectively underwent noncontrast-enhanced CT calcium scoring followed by coronary CT angiography performed in dual-energy mode. By using different reconstruction algorithms, three VNC series were generated and evaluated for noise and efficiency of virtual iodine removal. Two readers independently quantified calcium on VNC images and true noncontrast-enhanced conventional calcium scoring series. A leave-one-out cross validation was used to assess the accuracy of calcium score prediction from VNC series by means of linear regression. CT value histograms of the VNC series closely resembled the profile in the true noncontrast-enhanced series. There was excellent correlation between calcium volumes on the VNC series and true noncontrast-enhanced series on a per-patient (r = 0.94, P VNC series was excellent (r = 0.82). Multiethnic Study of Atherosclerosis rankings that were derived from the predicted calcium scores also showed excellent agreement (intraclass correlation coefficient = 0.909). Coronary artery calcium identification and quantification based on dual-energy coronary CT angiographic studies may obviate the need for dedicated CT calcium scoring studies. © RSNA, 2012

  1. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  3. A comparative study of planar, SPECT, x-ray CT and angiographic imaging in the detectability of space occupying lesion (SOL) of liver

    International Nuclear Information System (INIS)

    Manabe, Takao; Oda, Junro; Kamino, Toshio

    1986-01-01

    Planar, SPECT, X-CT, and angiography were compared in 47 patients with suspected SOL in the liver. SPECT had greater sensitivity and specificity in detecting SOLs than planar. Especially the detection of SOL less than 3 cm was improved, and the smallest SOL detected by SPECT was 1.0 cm in diameter. SPECT appears reliable procedure for screening SOLs in the liver. Compared with X-CT, SPECT had nearly equal sensitivity in detecting SOLs more than 3 cm, and X-CT had higher sensitivity in detecting SOLs less than 3 cm. But in some cases, for example isodensity SOL, SPECT could detect the SOL which was missed by X-CT. (author)

  4. Use of spiral CT angiography to judge central pulmonary vascular involvement from lung cancer

    International Nuclear Information System (INIS)

    Tan Qunyou; Zhao Shaohong; Wang Fangze; Cai Zulong

    2000-01-01

    Objective: To evaluate the accuracy of spiral CT angiography (SCTA) in judging central pulmonary vascular involvement from lung cancer located in the hilum and correlate the resultant images with pathologic and surgical findings. Methods: SCTA was done in 33 patients who were preoperatively diagnosed as having lung carcinoma located in the hilum. Contrast medium was injected at a rate of 3 ml/sec with a power injector. The delay time was from 20 to 25 seconds. The pitch was 1 with 3 mm-collimation. Images of central pulmonary arteries and veins were reconstructed with shaded surface display (SSD), maximum intensity projection (MIP), curved planar reformation (CPR), and multi-planar reformation (MPR). Then the relation between tumor and vessels was assessed prospectively on both 3 mm interval axial CT and SCTA images with comparison to subsequent pathologic or surgical findings. Results: (1) In showing the integrity of central pulmonary arteries and veins, images reconstructed by different ways of SCTA had different strong and weak points. (2) The grading standard in this study, with which the relation between vessels and tumor was judged, reflected the basic and common characters of central pulmonary vascular involvement by tumor located in the hilum. compared with axial CT images, SCTA was more accurate in judging the relation between central pulmonary vessels and tumor, and the correlation of SCTA imaging features with pathological patterns and surgical findings was better than that of axial CT images, P < 0.05 and P < 0.0001, respectively. Conclusion: It was feasible to show the relation between central pulmonary vessel and lung cancer located in the hilum with SCTA. And the accuracy of judging the vascular involvement with SCTA was higher than that with axial CT

  5. Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation

    Energy Technology Data Exchange (ETDEWEB)

    Carbone, Iacopo; Cannata, David; Algeri, Emanuela; Galea, Nicola; Napoli, Alessandro; Catalano, Carlo; Passariello, Roberto; Francone, Marco [Sapienza University of Rome, Department of Radiological, Onchological and Anatomopathological Sciences, Policlinico Umberto I, Rome (Italy); De Zorzi, Andrea [Bambino Gesu Hospital, Cardiology Division, Rome (Italy); Bosco, Giovanna; D' Agostino, Rita [Sapienza University of Rome, Unit of Paediatric Cardiology, Policlinico Umberto I, Rome (Italy); Menezes, Leon [University College of London, Institute of Nuclear Medicine, London (United Kingdom)

    2011-09-15

    Kawasaki disease (KD) is a systemic vasculitis that mainly affects coronary arteries in children, and requires regular follow-up from the time of diagnosis. To evaluate the feasibility of 64-slice CT angiography (CTA) for follow-up of patients with KD using previously performed invasive catheter coronary angiography (CCA) as reference standard. The study group comprised 12 patients (age 17.6 {+-} 2.9 years, mean{+-}SD) with a diagnosis of KD and a previously performed CCA (interval, 32.6 {+-} 13.5 months) who underwent 64-slice cardiac CTA. The quality of the images for establishing the presence of coronary abnormalities was determined by two observers. The CTA findings were compared with those from the prior CCA. Adequate image quality was obtained in all patients. Mean effective dose for CTA was 6.56 {+-} 0.95 mSv. CTA allowed accurate identification, characterization and measurement of all coronary aneurysms (n = 32), stenoses (n = 3) and occlusions (n = 9) previously demonstrated by CCA. One patient with disease progression went on to have percutaneous coronary intervention. Coronary lesions were reliably evaluated by 64-slice CTA in the follow-up of compliant patients with KD, reducing the need for repeated diagnostic invasive CCA. Hence, in an adequately selected patient population, the role of CCA could be limited almost only to therapeutic procedures. (orig.)

  6. Atherosclerotic Plaque Characteristics by CT Angiography Identify Coronary Lesions That Cause Ischemia: a Direct Comparison to Fractional Flow Reserve

    Science.gov (United States)

    Park, Hyung-Bok; Heo, Ran; Hartaigh, Bríain ó; Cho, Iksung; Gransar, Heidi; Nakazato, Ryo; Leipsic, Jonathon; Mancini, G.B. John; Koo, Bon-Kwon; Otake, Hiromasa; Budoff, Matthew J.; Berman, Daniel S.; Erglis, Andrejs; Chang, Hyuk-Jae; Min, James K.

    2014-01-01

    Objective We evaluated the association between atherosclerotic plaque characteristics (APCs) by coronary CT angiography (CT) and lesion ischemia by fractional flow reserve (FFR). Background FFR is the gold standard for determining lesion ischemia. While APCs by CT—including aggregate plaque volume % (%APV), positive remodeling (PR), low attenuation plaque (LAP) and spotty calcification (SC)—are associated with future coronary syndromes, their relationship to lesion ischemia is unclear. Methods 252 patients (17 centers, 5 countries) [mean age 63 years, 71% males] underwent CT, with FFR performed for 407 coronary lesions. CT was interpreted for 50% stenosis, with the latter considered obstructive. APCs by CT were defined as: (1) PR, lesion diameter/reference diameter >1.10; (2) LAP, any voxel 50% but not for 50%. PMID:25592691

  7. Multislice computed tomographic coronary angiography: experience in a UK centre

    International Nuclear Information System (INIS)

    Morgan-Hughes, G.J.; Marshall, A.J.; Roobottom, C.A.

    2003-01-01

    AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for 'assessability' and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition

  8. Reconstructions with identical filling (RIF) of the heart: a physiological approach to image reconstruction in coronary CT angiography

    International Nuclear Information System (INIS)

    Reinartz, S.D.; Diefenbach, B.S.; Kuhl, C.K.; Mahnken, A.H.; Allmendinger, T.

    2012-01-01

    To compare image quality in coronary artery computed tomography angiography (cCTA) using reconstructions with automated phase detection and Reconstructions computed with Identical Filling of the heart (RIF). Seventy-four patients underwent ECG-gated dual source CT (DSCT) between November 2009 and July 2010 for suspected coronary heart disease (n = 35), planning of transcatheter aortic valve replacement (n = 34) or evaluation of ventricular function (n = 5). Image data sets by the RIF formula and automated phase detection were computed and evaluated with the AHA 15-segment model and a 5-grade Likert scale (1: poor, 5: excellent quality). Subgroups regarding rhythm (sinus rhythm = SR; arrhythmia = ARR) and potential premedication were evaluated by a per-segment, per-vessel and per-patient analysis. RIF significantly improved image quality in 10 of 15 coronary segments (P < 0.05). More diagnostic segments were provided by RIF regarding the entire cohort (n = 693 vs. 590, P < 0.001) and all of the subgroups (e.g. ARR: n = 143 vs. 72, P < 0.001). In arrhythmic patients (n = 19), more diagnostic vessels (e.g. LAD: n = 10 vs. 3; P < 0.014) and complete data sets (n = 7 vs. 1; P < 0.001) were produced. RIF reconstruction is superior to automatic diastolic non-edited reconstructions, especially in arrhythmic patients. RIF theory provides a physiological approach for determining the optimal image reconstruction point in ECG-gated CT angiography. (orig.)

  9. Efficacy of dynamic CT perfusion imaging in conjunction with three dimensional CT angiography for the evaluation of acute ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Nakaguchi, Hiroshi; Teraoka, Akira; Adachi, Shinobu; Yanagibashi, Kazutaka [Teraoka Memorial Hospital, Shinichi, Hiroshima (Japan)

    2003-01-01

    Through the use of a high-speed spiral CT scanner (GEMedical HiSpeedZX/i), CT/P/A technique, where conventional CT, CT perfusion imaging (CTP) and CT angiography (CTA) are consecutively performed, can now be performed with an imaging time of 90 seconds and a total contrast medium volume of 100 ml. A prospective clinical study was performed to ascertain the effectiveness of CT/P/A in diagnosing acute ischemic strokes. Twenty-nine consecutive patients of Teraoka Memorial Hospital suspected of suffering from the occlusion or constriction of cerebral arteries and who underwent CT/P/A within 3 hours from the onset served as subjects. The sensitivity, specificity, or Odds ratio of CTP and CTA in detecting lesions that caused cerebral infarction was calculated. CTP detected a hypoperfusion area with a sensitivity, specificity, and Odds ratio of 80%, 64%, and 7.2. The sensitivity in lobar infarcts, white matter infarcts, basal ganglia infarcts, and brainstem infarcts was 100%, 100%, 100%, 0% (p=0.0022). The sensitivity and Odds ratio of CT/P/A in cerebral infarcts differed according to the diameter of the infarcts. That with infarcts of 10 mm or more was 91%, 20. That with infarcts smaller than 10 mm was 50%, 2. CTA detected arterial lesions that caused cerebral ischemic attack with a sensitivity of 94% and specificity of 90%. The examination time for CT/P/A was 18 minutes, total radiation time being 90 seconds. Although CT/P/A was ineffective for the diagnosis of brainstem infarcts and lesions smaller than 10 mm, CT/P/A was useful in detecting moderate-sized hypoperfusion areas and arterial lesions three-dimensionally before an infarct is completed. (author)

  10. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    International Nuclear Information System (INIS)

    Mastora, I.; Remy-Jardin, M.; Remy, J.; Suess, C.; Scherf, C.; Guillot, J.P.

    2001-01-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  11. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, I.; Remy-Jardin, M.; Remy, J. [Dept. of Radiology, University Center Hospital Calmette, Lille (France); Medical Research Group, Lille (France); Suess, C.; Scherf, C. [Siemens Medical Systems, Forcheim (Germany); Guillot, J.P. [Dept. of Radiology, University Center Hospital Calmette, Lille (France)

    2001-04-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  12. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  13. Removal of arterial wall calcifications in CT angiography by local subtraction

    International Nuclear Information System (INIS)

    Straten, Marcel van; Venema, Henk W.; Streekstra, Geert J.; Reekers, Jim A.; Heeten, Gerard J. den; Grimbergen, Cornelis A.

    2003-01-01

    CT Angiography (CTA) is an established technique for the minimally invasive imaging of arteries. The technique of maximum intensity projection (MIP) is often used to get a comprehensive overview of the vascular anatomy. On a MIP, however, arterial wall calcifications may hinder the visualization of the arterial lumen. These calcifications are in direct contact with the contrast-enhanced blood, which makes removal difficult. We present a local subtraction method for the automatic removal of these calcifications. In our approach a second CT scan has to be made, prior to contrast injection. The calcifications in both scans are registered prior to subtraction to compensate for displacements in between the two scans. Local subtraction results are compared with results obtained by thresholding. The method was tested in a phantom and with data from four patients. The phantom represented an artery with different types of stenosis. Data were used from patients for which CTA of the renal arteries was performed. For two patients the electrocardiogram (ECG) was recorded during the CTA examination, making retrospective cardiac gated reconstructions possible. Both the phantom and the patient study showed that the local subtraction method is capable of removing calcifications and visualizing the residual lumen. In the patient study it appeared that some artifacts remained for higher pitch values. We conclude that the local subtraction method is less subjective and more accurate than thresholding. Best results are obtained by use of a small pitch, at the expense of the volume covered during a single breath hold

  14. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    Science.gov (United States)

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  15. Topography of the accessory left gastric artery (ALGA) analyzed by CT angiography from the left hepatic artery

    International Nuclear Information System (INIS)

    Shioyama, Yasukazu; Takasaka, Isao; Onaya, Hiroaki

    2003-01-01

    To avoid gastric complications when we perform transcatheter treatment via left hepatic artery, we analyzed the topography of ALGA (accessory left gastric artery) by left hepatic arteriography and CT angiography from left hepatic artery. Six hundred seventy eight cases of CT angiography were performed between 1995 and 2000. Among them, selective left hepatic arteriography was done in 85 cases. We analyzed the frequency and the course of ALGA on the hepatic angiogram and CT angiogram. ALGA were identified in eighteen (21.2 %) of the 85 cases. We classified them into eleven cases of the proximal type and six cases of the distal type. When ALGA bifurcated from the left hepatic artery very close to the bifurcation of A2 (dorsolateral branch) and A3 (ventrolateral branch), we classified them as the distal type on hepatic angiogram. On the other hand, when ALGA bifurcated from the left hepatic artery apart from the bifurcation of A2 and A3 they were classified as the proximal type. In one rare case ALGA originated from the dorsolateral branch of the left hepatic artery. ALGA were classified as the distal and proximal types. Distal type of ALGA often overlapped dorsolateral branch of the left hepatic artery, and it was sometimes difficult to notice the existence of them. We should check the existence of ALGA on the arterial phase of dynamic CT before we plan to make a transcatheter treatment from the left hepatic artery. Then we can avoid gastric complications caused by a transcatheter treatment from the left hepatic artery. (author)

  16. Improved dynamic CT angiography visualization by flow territory masking

    Directory of Open Access Journals (Sweden)

    Søren Christensen

    2015-01-01

    Full Text Available Backgound and Purpose: Computerized tomography (CT perfusion (or CTP source images from CT scanners with small detector widths can be used to create a dynamic CT angiogram (CTA similar to digital subtraction angiography (DSA. Because CTP studies use a single intravenous injection, all arterial territories enhance simultaneously, and individual arterial territories [i.e., anterior cerebral artery (ACA, middle cerebral artery (MCA, and posterior cerebral artery (PCA] cannot be delineated. This limits the ability to assess collateral flow patterns on dynamic CTAs. The aim of this study was to devise and test a postprocessing method to selectively color-label the major arterial territories on dynamic CTA. Materials and Methods: We identified 22 acute-stroke patients who underwent CTP on a 320-slice CT scanner within 6 h from symptom onset. For each case, two investigators independently generated an arterial territory map from CTP bolus arrival maps using a semiautomated method. The volumes of the arterial territories were calculated for each map and the average relative difference between these volumes was calculated for each case as a measure of interrater agreement. Arterial territory maps were superimposed on the dynamic CTA to create a vessel-selective dynamic CTA with color-coding of the main arterial territories. Two experts rated the arterial territory maps and the color-coded CTAs for consistency with expected arterial territories on a 3-point scale (excellent, moderate, poor. Results: Arterial territory maps were generated for all 22 patients. The median difference in arterial territory volumes between investigators was 2.2% [interquartile range (IQR 0.6-8.5%]. Based on expert review, the arterial territory maps and the vessel-selective dynamic CTAs showed excellent consistency with the expected arterial territories in 18 of 22 patients, moderate consistency in 2 patients, and poor consistency in another 2 patients. Conclusion: Using a

  17. Low dose coronary CT angiography with 256-slice helical CT

    International Nuclear Information System (INIS)

    Zhang Xiaodong; Tang Binghang; Li Fangyun

    2011-01-01

    Objective: To compare the image quality and patient radiation dose of coronary computed tomography angiography (CCTA) received by prospectively-gated step-and-shoot (SAS) technique with those obtained by retrospectively-gated spiral ( RGS) technique on a 256-slice CT scanner. Methods: A total of 200 patients were enrolled in this study. One hundred patients underwent CCTA with SAS mode were subdivided into two groups: (1) 50 patients with an average heart rate (HR) ≤ 70 bpm were scanned with a data acquisition time window centered at the 75% of the R-R cycle (group A) and (2) 50 patients with HR > 70 bpm were scanned with the data acquisition time window centered at the 45% of the R-R cycle, including a phase tolerance of ± 5% (group B). Other 100 patients underwent CCTA with RGS mode and ECG-based tube current modulation were also subdivided into two groups: (3) 50 patients with HR ≤ 70 bpm were scanned with cardiac dose right set to phase of 75% ( group C) and (4) 50 patients with HR > 70 bpm were scanned with cardiac ose Rdight set to phases of 45% and 75% (group D). All patients were grouped in randomized order. The image quality of CCTA were evaluated using a rank scale from 1 to 4 (1: excellent; 4: non-assessable). Radiation dose of the four groups received was also estimated. The image quality between groups was compared by Mann-Whitney U test. The radiation dose between groups was compared by t test. For the 100 patients received by prospective ECG-gated CCTA, the receiver operating characteristic curve (ROC) was used to analyze the CCTA image quality and average heart rate to determine the uppercutoff of HR for obtaining diagnostic coronary images with SAS mode. A Spearman correlation analysis was also performed to analyze the correlation of HR and image quality in patients underwent CCTA with SAS mode. Results: Of 2338 coronary artery segments, excellent or good image quality (score of 1 or 2) was achieved in 96.5% (585 of 606) in group A, 77.7% (445

  18. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko [Sumi Hospital, Gifu (Japan); Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu

    1995-04-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author).

  19. Exploration of cervical carotid stenosis using helical CT angiography. A prospective trial on the detection of candidates for surgery in the Gujo area, Gifu

    International Nuclear Information System (INIS)

    Yamakawa, Hiroyasu; Sumi, Yasuhiko; Kaku, Yasuhiko; Sakai, Noboru; Yamada, Hiromu.

    1995-01-01

    To detect cervical carotid stenosis as a candidate for carotid endarterectomy (CEA), the authors attempted a prospective trial by exploring stenosis for one year in a rural district with a population of 20,000, employing helical CT angiography which apparently displayed three-dimensional reconstructed images of the carotid bifurcation. Thirty-three patients, 24 males and 9 females, with a mean age of 71.8 years, suffering from TIA, RIND or stroke were investigated for their carotid systems. The clinical symptoms of the patients were briefly as follows: motor weakness in 30 cases, dysarthria in 8 cases and aphasia in 4 cases; and 6 of 22 (27%) stroke cases had previously suffered an episode of TIA. The risk factors of the whole group of patients were hypertension in 13 cases, diabetes mellitus in 6, heart disease in 17, and hypercholesteremia in 4. Helical CT angiography was performed in 11 cases of TIA, 2 cases of RIND, and 16 cases of stroke. Only 3 cases of the TIA group and 3 cases of the stroke group were found to have extracranial carotid stenosis of more than 50%, which subsequently required conventional angiography. For the detection of stenosis, CT angiography was beneficial as well as conventional angiography. Finally, CEA was performed in 2 of 3 cases with severe carotid stonosis in the TIA group, while such cases in the stroke group were only observed. The above results meant that the occurrence of extracranial carotid stenosis was 6 out of 6,589 elderly inhabitants (over 60 years old), although the possible detection rate of candidates for CEA was 2 out of 20,000 population per year. (author)

  20. CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions

    Energy Technology Data Exchange (ETDEWEB)

    Muthusami, Prakash; Rea, Vanessa; Shroff, Manohar [The Hospital for Sick Children, Pediatric Neuroradiology and Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Shkumat, Nicholas [The Hospital for Sick Children, Medical Physics, Department of Diagnostic Imaging, Toronto, ON (Canada); Chiu, Albert H. [Institute of Neurological Sciences, Prince of Wales Hospital, Department of Interventional Neuroradiology, Randwick, NSW (Australia)

    2017-06-15

    Complex neurovascular lesions in children require precise anatomic understanding for treatment planning. Although 3DRA is commonly employed for volumetric reformation in neurointerventional procedures, the ability to reconstruct this data into CT-like images (3DRA-CT) is not widely utilized. This study demonstrates the feasibility and usefulness of 3DRA-CT and subsequent MRI fusion for problem solving in pediatric neuroangiography. This retrospective study includes 18 3DRA-CT studies in 16 children (age 9.6 ± 3.8 years, range 2-16 years) over 1 year. After biplane 2D-digital subtraction angiography (DSA), 5-second 3DRA was performed with selective vessel injection either with or without subtraction. Images were reconstructed into CT sections which were post-processed to generate multiplanar reformation (MPR) and maximum intensity projection (MIP) images. Fusion was performed with 3D T1 MRI images to precisely demonstrate neurovascular relationships. Quantitative radiation metrics were extracted and compared against those for the entire examination and for corresponding biplane 2D-DSA acquisitions. In all 18 cases, the 3DRA procedure and MRI fusion were technically successful and provided clinically useful information relevant to management. The unsubtracted and subtracted 3DRA acquisitions were measured to deliver 5.9 and 132.2%, respectively, of the mean radiation dose of corresponding biplane 2D-DSA acquisitions and contributed 1.2 and 12.5%, respectively, to the total procedure dose. Lower radiation doses, high spatial resolution, and multiplanar reformatting capability make 3DRA-CT a useful adjunct to evaluate neurovascular lesions in children. Fusing 3DRA-CT data with MRI is an additional capability that can further enhance diagnostic information. (orig.)

  1. Myocardial contrast defect associated with thrombotic coronary occlusion: Pre-autopsy diagnosis of a cardiac death with post-mortem CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Park, Hye Jin; Lee, Soo Kyoung; Yang, Kyung Moo [Dept. of Forensic Medicine, National Forensic Service, Wonju (Korea, Republic of)

    2015-10-15

    We report the case of a female who died of suspected acute myocardial infarction. Post-mortem CT angiography (PMCTA) was performed with intravascular contrast infusion before the standard autopsy, and it successfully demonstrated the complete thrombotic occlusion of a coronary artery and also a corresponding perfusion defect on myocardium. We herein describe the PMCTA findings of a cardiac death with special emphasis on the potential benefits of this novel CT technique in forensic practice.

  2. Identification of the segmental artery feeding the anterior spinal artery. Correlation between helical CT and angiography

    International Nuclear Information System (INIS)

    Nishimura, Jun-ichi; Lee, Jin; Koike, Shigeomi

    2005-01-01

    We investigated whether identification of the segmental artery feeding the anterior spinal artery (ASA) is possible by single-slice helical CT. Enhanced CT and angiography were performed in 14 patients with retroperitoneal, liver, or bone tumor. A single-slice helical CT scanner with 7 mm collimation and a 1.0 helical pitch was used. Scanning was started 25 to 30 sec after an intravenous injection of 100 ml of contrast medium at a rate of 3.0 ml/sec. We predicted the segmental artery feeding the ASA in all 14 patients using enhanced CT images. In 12 of the 14 patients, the segmental artery feeding the ASA was angiographically identified. In 7 of these 12 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was the same level as that predicted by enhanced CT. In the remaining 5 patients, the level of the segmental artery feeding the ASA identified on segmental arteriogram was one level higher or lower than the predicted spinal level. We could identify the segmental artery feeding the ASA by detailed examination and interpretation of single-slice helical CT images. (author)

  3. Prevalence and clinical significance of extravascular incidental findings in patients undergoing CT cervico-cerebral angiography

    International Nuclear Information System (INIS)

    Crockett, Matthew Thomas; Murphy, Blathnaid; Smith, Jennifer; Kavanagh, Eoin Carl

    2015-01-01

    Highlights: • CT cervico-cerebral angiography (CTCCA) is a commonly performed study for assessment of vascular pathologies of head and neck. • This study assessed the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. • This study demonstrated the presence of clinically significant incidental findings in 14% of patients undergoing CTCCA with 8% of these findings deemed to be highly significant. 19% of patients with highly clinically significant findings did not receive appropriate follow up. • A standardised method of reporting incidental findings, such as that used in this paper is suggested to aid radiologists and referring physicians in recording and communicating these findings. - Abstract: Introduction: CT cervico-cerebral angiography (CTCCA) is now the first line diagnostic imaging modality for the majority of vascular pathologies of the head and neck with diagnostic value comparable to or better than traditional angiographic techniques. The aim of this study was to assess the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. Materials and methods: A retrospective review of the CTCCA reports of 302 consecutive patients from 2009 to 2013 was undertaken. Extravascular incidental findings were classified, according to an adaptation of the CT colonography data and reporting system (CRADS), as EV1–EV4. EV1 = no incidental findings, EV2 = clinically insignificant incidental finding, EV3 = incidental finding of intermediate clinical significance, EV4 = highly clinically significant finding. Follow up of the electronic medical records of patients with EV3 or EV4 findings was undertaken to determine subsequent management. Results: Potentially clinically significant findings were demonstrated in 14.2% of patients with 8.6% of patients having a highly clinically significant finding. 4 incidental findings were confirmed to be malignant lesions and 5

  4. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  5. Influence of heart rate on diagnostic accuracy and image quality of 16-slice CT coronary angiography: comparison of multisegment and halfscan reconstruction approaches

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc; Teige, Florian; Hamm, Bernd [Charite - Universitaetsmedizin Berlin, Humboldt-Universitaet zu Berlin, Department of Radiology, Chariteplatz 1, P.O. Box 10098, Berlin (Germany); Laule, Michael [Department of Cardiology, Charite, Berlin (Germany)

    2007-11-15

    The lower the heart rate the better image quality in multislice computed tomography (MSCT) coronary angiography. We prospectively assessed the influence of heart rate on per-patient diagnostic accuracy and image quality of MSCT coronary angiography and compared adaptive multisegment and standard halfscan reconstruction. A consecutive cohort of 126 patients scheduled to undergo conventional coronary angiography was examined with 16-slice CT. For all heart rate groups, per-patient diagnostic accuracy was significantly higher for multisegment than halfscan reconstruction with values of 95 vs. 79% (p < 0.05, <65 bpm, 38 patients), 85 vs. 66% (p < 0.05, 65-74 bpm, 47 patients), and 78% vs. 41% (p < 0.001, >74 bpm, 41 patients). Differences in diagnostic accuracy between adjacent heart rate groups were only significant for halfscan reconstruction for the comparison between the 65-74 and >74 bpm group (p < 0.05). The vessel lengths free of motion artifacts were significantly longer with multisegment reconstruction in all heart rate groups and for all coronary arteries (p < 0.005). For noninvasive MSCT coronary angiography, both per-patient diagnostic accuracy and image quality decline with increasing heart rate, and multisegment reconstruction at high heart rates yields similar results as standard halfscan reconstruction at low heart rates. (orig.)

  6. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    International Nuclear Information System (INIS)

    Sabharwal, Rohan; Vladica, Philip; Coleman, Patrick

    2007-01-01

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  7. Detection of intra-cardiac thrombi and congestive heart failure in cats using computed tomographic angiography.

    Science.gov (United States)

    Vititoe, Kyle P; Fries, Ryan C; Joslyn, Stephen; Selmic, Laura E; Howes, Mark; Vitt, Jordan P; O'Brien, Robert T

    2018-04-16

    Arterial thromboembolism is a life-threatening condition in cats most commonly secondary to cardiac disease. Echocardiography is the reference standard to evaluate for presence of a thrombus. In humans, computed tomographic (CT) angiography is becoming widely used to detect left atrial thrombi precluding the use of sedation. The purpose of this prospective, controlled, methods comparison pilot study was threefold: (1) describe new CT angiography protocol used in awake cats with cardiac disease and congestive heart failure; (2) determine accuracy of continuous and dynamic acquisition CT angiography to identify and characterize cardiac thrombi from spontaneous echocardiographic contrast using transthoracic echocardiography as our reference standard; (3) identify known negative prognostic factors and comorbidities of the thorax that CT angiography may provide that complement or supersede echocardiographic examination. Fourteen cats with heart disease were recruited; 7 with thrombi and 7 with spontaneous echocardiographic contrast. Echocardiography and awake CT angiography were performed using a microdose of contrast. Six of 7 thrombi were identified on CT angiography as filling defects by at least one reviewer within the left auricle (n = 6) and right heart (n = 1). Highest sensitivity (71.4%) was in continuous phase and highest specificity (85.7%) was in dynamic studies with fair to moderate interobserver agreement (0.38 and 0.44). CT angiography identified prognostic cardiac information (left atrial enlargement, congestive heart failure, arterial thromboembolism) and comorbidities (suspected idiopathic pulmonary fibrosis, asthma). This study indicates CT angiography can readily identify cardiac thrombi, important prognostic information and comorbidities, and can be safely performed in cats with cardiac disease and congestive heart failure. © 2018 American College of Veterinary Radiology.

  8. Reconstruction-of-difference (RoD) imaging for cone-beam CT neuro-angiography

    Science.gov (United States)

    Wu, P.; Stayman, J. W.; Mow, M.; Zbijewski, W.; Sisniega, A.; Aygun, N.; Stevens, R.; Foos, D.; Wang, X.; Siewerdsen, J. H.

    2018-06-01

    Timely evaluation of neurovasculature via CT angiography (CTA) is critical to the detection of pathology such as ischemic stroke. Cone-beam CTA (CBCT-A) systems provide potential advantages in the timely use at the point-of-care, although challenges of a relatively slow gantry rotation speed introduce tradeoffs among image quality, data consistency and data sparsity. This work describes and evaluates a new reconstruction-of-difference (RoD) approach that is robust to such challenges. A fast digital simulation framework was developed to test the performance of the RoD over standard reference reconstruction methods such as filtered back-projection (FBP) and penalized likelihood (PL) over a broad range of imaging conditions, grouped into three scenarios to test the trade-off between data consistency, data sparsity and peak contrast. Two experiments were also conducted using a CBCT prototype and an anthropomorphic neurovascular phantom to test the simulation findings in real data. Performance was evaluated primarily in terms of normalized root mean square error (NRMSE) in comparison to truth, with reconstruction parameters chosen to optimize performance in each case to ensure fair comparison. The RoD approach reduced NRMSE in reconstructed images by up to 50%–53% compared to FBP and up to 29%–31% compared to PL for each scenario. Scan protocols well suited to the RoD approach were identified that balance tradeoffs among data consistency, sparsity and peak contrast—for example, a CBCT-A scan with 128 projections acquired in 8.5 s over a 180°  +  fan angle half-scan for a time attenuation curve with ~8.5 s time-to-peak and 600 HU peak contrast. With imaging conditions such as the simulation scenarios of fixed data sparsity (i.e. varying levels of data consistency and peak contrast), the experiments confirmed the reduction of NRMSE by 34% and 17% compared to FBP and PL, respectively. The RoD approach demonstrated superior performance in 3D angiography

  9. Optimizing CT angiography in patients with Fontan physiology: single-center experience of dual-site power injection

    International Nuclear Information System (INIS)

    Sandler, K.L.; Markham, L.W.; Mah, M.L.; Byrum, E.P.; Williams, J.R.

    2014-01-01

    Aim: To identify adult patients with single-ventricle congenital heart disease and Fontan procedure palliation who have been misdiagnosed with or incompletely evaluated for pulmonary embolism. Additionally, this study was designed to demonstrate that simultaneous, dual-injection of contrast medium into an upper and lower extremity vein is superior to single-injection protocols for CT angiography (CTA) of the chest in this population. Materials and methods: Patients included in the study were retrospectively selected from the Adult Congenital Heart Disease (ACHD) database. Search criteria included history of Fontan palliation and available chest CT examination. Patients were evaluated for (1) type of congenital heart disease and prior operations;(2) indication for initial CT evaluation;(3) route of contrast medium administration for the initial CT examination and resulting diagnosis;(4) whether or not anticoagulation therapy was initiated; and (5) final diagnosis and treatment plan. Results: The query of the ACHD database resulted in 28 individuals or patients with Fontan palliation (superior and inferior venae cavae anastomosed to the pulmonary arteries). Of these, 19 patients with Fontan physiology underwent CTA of the pulmonary circulation, and 17 had suboptimal imaging studies. Unfortunately, seven of these 17 patients (41%) were started on anticoagulation therapy due to a diagnosis of pulmonary embolism that was later excluded. Conclusion: Patients with single-ventricle/Fontan physiology are at risk of thromboembolic disease. Therefore, studies evaluating their complex anatomy must be performed with the optimal imaging protocol to ensure diagnostic accuracy, which is best achieved with dual-injection of an upper and lower extremity central vein. - Highlights: • The adult congenital heart disease population is growing. • Many of these patients have single ventricle/Fontan physiology. • Patients with Fontan physiology are at increased risk for

  10. Flat-detector computed tomography in the assessment of intracranial stents: comparison with multi detector CT and conventional angiography in a new animal model

    International Nuclear Information System (INIS)

    Struffert, Tobias; Ott, Sabine; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Doerfler, Arnd; Deuerling-Zheng, Yu

    2011-01-01

    Careful follow up is necessary after intracranial stenting because in-stent restenosis (ISR) or residual stenosis (RS) is not rare. A minimally invasive follow-up imaging technique is desirable. The objective was to compare the visualisation of stents in Flat Detector-CT Angiography (FD-CTA) after intravenous contrast medium injection (i.v.) with Multi Detector Computed Tomography Angiography (MD-CTA) and Digital Subtracted Angiography (DSA) in an animal model. Stents were implanted in the carotid artery of 12 rabbits. In 6 a residual stenosis (RS) was surgically created. Imaging was performed using FD-CTA, MD-CTA and DSA. Measurements of the inner and outer diameter and cross-section area of the stents were performed. Stenosis grade was calculated. In subjective evaluation FD-CTA was superior to MD-CTA. FD-CTA was more accurate compared with DSA than MD-CTA. Cross-sectional area of the stent lumen was significantly larger (p < 0.05) in FD-CTA in comparison to MD-CTA. Accurate evaluation of stenosis was impossible in MD-CTA. There was no statistically significant difference in the stenosis grade of DSA and FD-CTA. Our results show that visualisation of stent and stenosis using intravenous FD-CTA compares favourably with DSA and may replace DSA in the follow-up of patients treated with intracranial stents. (orig.)

  11. Noninvasive detection of coronary vasospastic angina using a double-acquisition coronary CT angiography protocol in the presence and absence of an intravenous nitrate: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun-Ju; Kim, Dong Won; Yoon, Seong Kuk; Lee, Ki-Nam [Dong-A University, Department of Radiology, College of Medicine, Busan (Korea, Republic of); Kim, Moo Hyun; Jin, Cai De [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Dong-A University Hospital, Global Clinical Trial Center, Busan (Korea, Republic of); Seo, Jeongmin; Park, Tae-Ho [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Choi, Sang Il [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si (Korea, Republic of); Yoon, Yeonyee Elizabeth [Seoul National University Bundang Hospital, Department of Cardiology, Seongnam-si (Korea, Republic of)

    2017-03-15

    To evaluate the feasibility of a double-acquisition coronary CT angiography (CCTA) protocol in the presence and absence of an intravenous (IV) vasodilator infusion for detecting vasospastic angina. Twenty patients with a high clinical probability of vasospastic angina were enrolled. All subjects underwent baseline CCTA without a vasodilator in the early morning followed by a catheterized coronary angiography with ergonovine provocation test. Within 3 days, all subjects underwent repeat CCTA during a continuous IV infusion of nitrate. Vasospastic angina as detected by CCTA was defined as significant stenosis (≥50 %) with negative remodelling without definite plaques or diffuse small diameter (<2 mm) of a major coronary artery with a beaded appearance on baseline CT that completely dilated on IV nitrate CT. The CCTA results were compared to the catheterized ergonovine provocation test as the reference standard. Among 20 patients, the catheterized ergonovine provocation test detected vasospasm in 15 patients. The sensitivity, specificity, positive predictive value and negative predictive value of CCTA in a per-patient-based analysis were 73, 100, 100 and 56 %, respectively. Double-acquisition CCTA in the presence and absence of IV infusion of nitrate allows noninvasive detection of vasospastic angina with moderate sensitivity and high specificity. (orig.)

  12. A database for estimating organ dose for coronary angiography and brain perfusion CT scans for arbitrary spectra and angular tube current modulation

    International Nuclear Information System (INIS)

    Rupcich, Franco; Badal, Andreu; Kyprianou, Iacovos; Schmidt, Taly Gilat

    2012-01-01

    Purpose: The purpose of this study was to develop a database for estimating organ dose in a voxelized patient model for coronary angiography and brain perfusion CT acquisitions with any spectra and angular tube current modulation setting. The database enables organ dose estimation for existing and novel acquisition techniques without requiring Monte Carlo simulations. Methods: The study simulated transport of monoenergetic photons between 5 and 150 keV for 1000 projections over 360° through anthropomorphic voxelized female chest and head (0° and 30° tilt) phantoms and standard head and body CTDI dosimetry cylinders. The simulations resulted in tables of normalized dose deposition for several radiosensitive organs quantifying the organ dose per emitted photon for each incident photon energy and projection angle for coronary angiography and brain perfusion acquisitions. The values in a table can be multiplied by an incident spectrum and number of photons at each projection angle and then summed across all energies and angles to estimate total organ dose. Scanner-specific organ dose may be approximated by normalizing the database-estimated organ dose by the database-estimated CTDI vol and multiplying by a physical CTDI vol measurement. Two examples are provided demonstrating how to use the tables to estimate relative organ dose. In the first, the change in breast and lung dose during coronary angiography CT scans is calculated for reduced kVp, angular tube current modulation, and partial angle scanning protocols relative to a reference protocol. In the second example, the change in dose to the eye lens is calculated for a brain perfusion CT acquisition in which the gantry is tilted 30° relative to a nontilted scan. Results: Our database provides tables of normalized dose deposition for several radiosensitive organs irradiated during coronary angiography and brain perfusion CT scans. Validation results indicate total organ doses calculated using our database are

  13. Diagnostic imaging of acute aortic dissection; Evaluation of thrombosed type aortic dissection by CT and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ohya, Tohru; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1991-01-01

    One hundred and nineteen patients with aortic dissection who underwent diagnostic imaging were reviewed and angiographic findings as well as those of CT were analysed. Thirty eight cases (43.1%) had non-contrast opacified false lumen, the type of which we call 'thrombosed type aortic dissection'. A comparative study of the thrombosed type with the patent type of false lumens was made particularly from the stand point of the characteristic diagnostic imagings (CT and angiography). At the same time, the pitfalls of these imagings in thrombosed type aortic dissection were studied. At the onset the average age of thrombosed type was 62.3 years old, while that of the patent type was 57.3. A statistical significance between the two groups was p<0.05. Thrombosed type in all cases was caused by atherosclerosis, whereas patent type was caused by the Marfan's syndrome in 11 cases. Other clinical findings, such as initial symptoms and blood pressure revealed no significant differences between the two groups. Pre-contrast CT in acute thrombosed type aortic dissection showed 'hyperdense crescent sign' in 89.4%. However, in 3 cases with thrombosed type in which the pre-contrast CT showed 'hyperdense crescent sign' contrast-enhanced CT detected no clear evidence of aortic dissection in the same site. This was due to obscurity induced by contrast medium. Angiographic findings of thrombosed type were classified into 3 groups: normal type, stenosed true lumen type and ulcer-like projection type. The incidence of normal type was estimated to be 48.4%, whereas stenosed true lumen type was 24.2% and ulcer-like projection was 27.7%. The present study concluded that thrombosed type is not rare in acute aortic dissection and contrast-enhanced CT as well as pre-contrast CT, is of great value in diagnosing thrombosed type. 'Hyperdense crescent sign' in pre-contrast CT is characteristic of intramural hematoma. (author).

  14. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Latson, Larry A.; Truong, Mylene T.; Aaltonen, Eric; Shiau, Maria C.; Girvin, Francis; Alpert, Jeffrey B.; Wickstrom, Maj; Ko, Jane P.

    2016-01-01

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  15. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: bedros.taslakian@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Latson, Larry A., E-mail: larry.latson@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Truong, Mylene T., E-mail: mtruong@mdanderson.org [Department of Radiology, University of Texas, MD Anderson Cancer Center, TX (United States); Aaltonen, Eric, E-mail: Eric.Aaltonen@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Shiau, Maria C., E-mail: Maria.Shiau@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Girvin, Francis, E-mail: Francis.Girvin@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Alpert, Jeffrey B., E-mail: Jeffrey.Alpert@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Wickstrom, Maj, E-mail: Maj.Wickstrom@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States); Ko, Jane P., E-mail: Jane.Ko@nyumc.org [Department of Radiology, NYU Langone Medical Center, NY (United States)

    2016-11-15

    Highlights: • CTPA plays a key role in the evaluation of pulmonary vascular diseases. • Improvements in CT technology have improved visualization of pulmonary arteries. • Knowledge of the technical pitfalls is essential for accurate diagnosis. • Dual energy CT imaging enables parenchymal iodine evaluation. • An awareness of the entities affecting the pulmonary arteries is important. - Abstract: Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  16. Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

    International Nuclear Information System (INIS)

    Takx, Richard A.P.; Schoepf, U. Joseph; Moscariello, Antonio; Das, Marco; Rowe, Garrett; Schoenberg, Stefan O.; Fink, Christian; Henzler, Thomas

    2013-01-01

    Objective: To prospectively compare subjective and objective image quality in 20% tube current coronary CT angiography (cCTA) datasets between an iterative reconstruction algorithm (SAFIRE) and traditional filtered back projection (FBP). Materials and methods: Twenty patients underwent a prospectively ECG-triggered dual-step cCTA protocol using 2nd generation dual-source CT (DSCT). CT raw data was reconstructed using standard FBP at full-dose (Group 1 a) and 80% tube current reduced low-dose (Group 1 b). The low-dose raw data was additionally reconstructed using iterative raw data reconstruction (Group 2 ). Attenuation and image noise were measured in three regions of interest and signal-to-noise-ratio (SNR) as well as contrast-to-noise-ratio (CNR) was calculated. Subjective diagnostic image quality was evaluated using a 4-point Likert scale. Results: Mean image noise of group 2 was lowered by 22% on average when compared to group 1 b (p 2 compared to group 1 b (p 2 (1.88 ± 0.63) was also rated significantly higher when compared to group 1 b (1.58 ± 0.63, p = 0.004). Conclusions: Image quality of 80% tube current reduced iteratively reconstructed cCTA raw data is significantly improved when compared to standard FBP and consequently may improve the diagnostic accuracy of cCTA

  17. Electron-beam CT coronary angiography in the patients with high heart rate arrhythmia or pacemaker

    International Nuclear Information System (INIS)

    Dong Zhi; Zhu Jiemin; Liu Zhe; Liu Junbo; Li Youjie; Qi Ji

    2006-01-01

    Objective: To report the clinical applicability of coronary angiography for patients with high heart rate, arrhythmia or cardiac pacing using the new-generation of electron-beam CT (e-Speed). Methods: EBCT (GE e-Speed) coronary angiography was performed in 36 eases (male 27, female 9, mean age 58), including the heart rate more than 90 bpm in 20 patients, frequent ectopic beats in 11 cases, implantation of cardiac pacemaker in 4 patients and the unacceptable MSCT image quality due to variability of interscan heart rate (from 82 bpm to 104 bpm) in 1 case. After volume data set was acquired using spiral mode with prospective ECG-gating, the reconstructions of MIP, CPR, VR and Cine were performed. The VR quality was evaluated using a five-point scale. Results: The quality of coronary imaging in all of 36 cases were acceptable. The total visualization rate of coronary artery branches was 80.0%. Left main, left anterior artery and right coronary artery were visualized in all patients and in 94.3% of all cases circumflex artery were visible. Conclusion: EBCT (e-Speed) is applicable in noninvasive coronary angiography for patients with high heart rate, arrhythmia or implanted cardiac pacemaker', and this examination can obtain satisfied diagnosis. (authors)

  18. 64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents

    International Nuclear Information System (INIS)

    Maintz, David; Seifarth, Harald; Rink, Michael; Oezguen, Murat; Heindel, Walter; Fischbach, Roman; Raupach, Rainer; Flohr, Thomas; Sommer, Torsten

    2006-01-01

    The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, (2) soft, 0.75, (3) medium soft, 0.6, and (4) stent-optimized sharp, 0.6. To evaluate visualization characteristics of of the stent, the lumen diameter, intraluminal density and noise were measured. The high-resolution kernel offered significantly better average lumen visualization (57% ±10%) and more realistic lumen attenuation (222 HU ±66 HU) at the expense of increased noise (15.3 HU ±3.7 HU) compared with the soft and medium-soft CT angiography (CTA) protocol (p<0.001 for all). Stents with a lumen visibility of more than 66% were: Arthos pico, Driver, Flex, Nexus2, S7, Tenax complete, Vision (all 67%), Symbiot, Teneo (70%), and Radius (73%). Only ten stents showed a lumen visibility of less than 50%. Stent lumen visibility largely varies depending on the stent type. Even with the improved spatial resolution of 64-slice CT, a stent-optimized kernel remains beneficial for stent visualization when compared with the standard medium-soft CTA protocol. Using 64-slice CT and high-resolution kernel, the majority of stent products show a lumen visibility of more than 50% of the stent

  19. Clinical evaluation of bone-subtraction CT angiography (BSCTA) in head and neck imaging

    International Nuclear Information System (INIS)

    Lell, M.; Anders, K.; Bautz, W.; Klotz, E.; Ditt, H.; Tomandl, B.F.

    2006-01-01

    Fifty-one patients were examined with bone subtraction CT angiography (BSCTA). Data were acquired on 4-and 64-slice spiral CT systems. The post-processing method is based on fully automatic registration of non-enhanced and contrast-enhanced CT data and subsequent selective bone removal. Vascular structures and brain tissue are retained with the original CTA noise level. Image quality and delineation of the pathologic process were assessed and artifacts introduced by the bone removal process recorded. The bone subtraction algorithm worked successfully in all examinations. The processing time was 6 min on average. Image quality was rated excellent in 20 (39%), good in 26 (51%) and acceptable in 5 (10%) patients. Ophthalmic arteries were visible in 12 (24%) patients bilaterally, in 13 (25%) patients unilaterally and in 26 (51%) patients at least at the origin. BSCTA improved visualization of the infraclinoid ICA and the vertebral arteries. The depiction of stenosis of the extracranial ICA and supraclinoid aneurysms was not significantly improved. In patients with suspicion of sinus thrombosis, BSCTA and conventional CTA yielded similar results. To conclude, BSCTA improves the visualization of vessels with close contact to bone and can improve the diagnostic accuracy and therapy planning of infraclinoid aneurysms. (orig.)

  20. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm

    International Nuclear Information System (INIS)

    Baumann, Stefan; Wang, Rui; Schoepf, U.J.; Steinberg, Daniel H.; Spearman, James V.; Bayer, Richard R.; Hamm, Christian W.; Renker, Matthias

    2015-01-01

    The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. (orig.)

  1. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  2. Improved Outcome Prediction Using CT Angiography in Addition to Standard Ischemic Stroke Assessment: Results from the STOPStroke Study

    Science.gov (United States)

    González, R. Gilberto; Lev, Michael H.; Goldmacher, Gregory V.; Smith, Wade S.; Payabvash, Seyedmehdi; Harris, Gordon J.; Halpern, Elkan F.; Koroshetz, Walter J.; Camargo, Erica C. S.; Dillon, William P.; Furie, Karen L.

    2012-01-01

    Purpose To improve ischemic stroke outcome prediction using imaging information from a prospective cohort who received admission CT angiography (CTA). Methods In a prospectively designed study, 649 stroke patients diagnosed with acute ischemic stroke had admission NIH stroke scale scores, noncontrast CT (NCCT), CTA, and 6-month outcome assessed using the modified Rankin scale (mRS) scores. Poor outcome was defined as mRS>2. Strokes were classified as “major” by the (1) Alberta Stroke Program Early CT Score (ASPECTS+) if NCCT ASPECTS was≤7; (2) Boston Acute Stroke Imaging Scale (BASIS+) if they were ASPECTS+ or CTA showed occlusion of the distal internal carotid, proximal middle cerebral, or basilar arteries; and (3) NIHSS for scores>10. Results Of 649 patients, 253 (39.0%) had poor outcomes. NIHSS, BASIS, and age, but not ASPECTS, were independent predictors of outcome. BASIS and NIHSS had similar sensitivities, both superior to ASPECTS (p10/BASIS+ had poor outcomes, versus 21.5% (77/358) with NIHSS≤10/BASIS− (p10/BASIS+ compared to patients who are NIHSS≤10/BASIS−; the odds ratio is 5.4 (95% CI: 3.5 to 8.5) when compared to patients who are only NIHSS>10 or BASIS+. Conclusions BASIS and NIHSS are independent outcome predictors. Their combination is stronger than either instrument alone in predicting outcomes. The findings suggest that CTA is a significant clinical tool in routine acute stroke assessment. PMID:22276182

  3. Helical CT angiography of renal arteries: two-years of experience

    International Nuclear Information System (INIS)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L.

    1997-01-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec. Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors)

  4. High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, Bernhard, E-mail: bernhard.bischoff@med.uni-muenchen.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Meinel, Felix G. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Del Prete, Alessandra [Department of Radiology Magrassi-Lanzara, Second University of Naples, Naples (Italy); Reiser, Maximilian F.; Becker, Hans-Christoph [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany)

    2013-12-01

    Background: Coronary CT angiography (CCTA) is usually performed during breath holding to reduce motion artifacts caused by respiration. However, some patients are not able to follow the breathing commands adequately due to deafness, hearing impairment, agitation or pulmonary diseases. The aim of this study was to evaluate the potential of high-pitch CCTA in free breathing patients when compared to breath holding patients. Methods: In this study we evaluated 40 patients (20 free breathing and 20 breath holding patients) with a heart rate of 60 bpm or below referred for CCTA who were examined on a 2nd generation dual-source CT system. Image quality of each coronary artery segment was rated using a 4-point grading scale (1: non diagnostic–4: excellent). Results: Mean heart rate during image acquisition was 52 ±5 bpm in both groups. There was no significant difference in mean image quality, slightly favoring image acquisition during breath holding (mean image quality score 3.76 ± 0.32 in breath holding patients vs. 3.61 ± 0.45 in free breathing patients; p = 0.411). Due to a smaller amount of injected contrast medium, there was a trend for signal intensity to be slightly lower in free breathing patients, but this was not statistically significant (435 ± 123 HU vs. 473 ± 117 HU; p = 0.648). Conclusion: In patients with a low heart rate who are not able to hold their breath adequately, CCTA can also be acquired during free breathing without substantial loss of image quality when using a high pitch scan mode in 2nd generation dual-source CT.

  5. Automated quantification of epicardial adipose tissue using CT angiography: evaluation of a prototype software

    International Nuclear Information System (INIS)

    Spearman, James V.; Silverman, Justin R.; Krazinski, Aleksander W.; Costello, Philip; Meinel, Felix G.; Geyer, Lucas L.; Schoepf, U.J.; Apfaltrer, Paul; Canstein, Christian; De Cecco, Carlo Nicola

    2014-01-01

    This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFV M segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFV A calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. The final EFV A (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P 0.9). Automated EFV A quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. (orig.)

  6. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  7. CT during selective arteriography: anatomical assessment of unruptured intracranial aneurysms before endovascular treatment

    International Nuclear Information System (INIS)

    Nomura, M.; Kida, S.; Uchiyama, N.; Yamashima, T.; Yamashita, J.; Sanada, J.; Yoshikawa, J.; Matsui, O.

    2001-01-01

    Our aim was to investigate the usefulness of helical CT during selective angiography (CT arteriography) in pretreatment assessment of unruptured intracranial aneurysms. We studied 47 unruptured aneurysms in 34 prospectively recruited patients for whom endovascular embolisation was initially considered. As pretreatment assessment, we performed rotational digital subtraction angiography (DSA) followed by CT arteriography. The findings on axial source images (axial images) and reconstructed three-dimensional CT angiography (3D-CTA) of CT arteriography were compared to those of rotational DSA, with particular attention to the neck of the aneurysm and arterial branches adjacent to it. Information provided by CT arteriography was more useful than that of rotational DSA as regards the neck in 25 (53 %) of 47 cases and as regards branches in 18 (49 %) of 37 aneurysms. On axial images, small arteries such as the anterior choroidal artery were seen in some cases. CT arteriography can provide valuable additional information about unruptured aneurysms, which cannot be obtained by rotational DSA alone. This technique is useful for obtaining anatomical information about aneurysm anatomy and for deciding the therapeutic strategy. (orig.)

  8. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  9. Cone-Beam CT with Flat-Panel-Detector Digital Angiography System: Early Experience in Abdominal Interventional Procedures

    International Nuclear Information System (INIS)

    Hirota, Shozo; Nakao, Norio; Yamamoto, Satoshi; Kobayashi, Kaoru; Maeda, Hiroaki; Ishikura, Reiichi; Miura, Koui; Sakamoto, Kiyoshi; Ueda, Ken; Baba, Rika

    2006-01-01

    We developed a cone-beam computed tomography (CBCT) system equipped with a large flat-panel detector. Data obtained by 200 o rotation imaging are reconstructed by means of CBCT to generate three-dimensional images. We report the use of CBCT angiography using CBCT in 10 patients with 8 liver malignancies and 2 hypersplenisms during abdominal interventional procedures. CBCT was very useful for interventional radiologists to confirm a perfusion area of the artery catheter wedged on CT by injection of contrast media through the catheter tip, although the image quality was slightly degraded, scoring as 2.60 on average by streak artifacts. CBCT is space-saving because it does not require a CT system with a gantry, and it is also time-saving because it does not require the transfer of patients

  10. Intra-arterial CT-angiography for cerebral arteriovenous malformation--initial experiences for treatment planning of radiosurgery

    International Nuclear Information System (INIS)

    Kunieda, Etsuo; Kawaguchi, Osamu; Onozuka, Satoshi; Momoshima, Suketaka; Takeda, Atsuya; Shigematsu, Naoyuki; Hashimoto, Subaru; Ohira, Takayuki; Kubo, Atsushi

    2002-01-01

    Purpose: To clarify the feasibility and effectiveness of intra-arterial CT angiography (IACTA) for treatment planning of arteriovenous malformation radiosurgery. Methods and Materials: A CT scanner installed in an angiographic examination room was used. Helical IACTA was performed in 22 patients during continuous intra-arterial infusion of contrast medium via the internal carotid or vertebral artery, and dynamic IACTA was performed in 20 of these patients with reconstruction at 0.2-s intervals. The dynamic IACTA was repeated for each 3- or 5-mm increment to encompass the nidus. Subtractions were performed in postembolization cases. A retrospective review of IACTA was performed to assess the effectiveness of dynamic scans. Results: No complications related to the angiographic procedure or CT imaging were detected. High contrast enhancement was obtained for both helical and dynamic IACTA. In 18 of the 20 cases (90%), draining veins were separated from the nidus by using the enhancement patterns, and in 13 cases (65%), feeding arteries were separated. Conclusion: Dynamic IACTA added important information for target-volume determinations. Conventional CT and MRI could be omitted from the protocol, and the period that patients wore the frame was substantially shortened. We conclude that IACTA is a practical and useful method for radiosurgical treatment planning of arteriovenous malformations

  11. Propagation of aortic dissection and visceral artery compromise. Three-dimensional analysis on CT angiography

    International Nuclear Information System (INIS)

    Minamiguchi, Hiroki

    2003-01-01

    The purpose of this study was to clarify the patterns of the propagation of aortic dissection with quantitative data from CT angiography and to verify the relationship between the propagation of aortic dissection and visceral artery compromise. The subjects were 67 cases (48 men, 19 women) with acute and subacute aortic dissection extending from the descending thoracic aorta to the aortic bifurcation. The mean age is 56.5±12.3 years old (range 34 to 80 years). Eight axial levels of the trunk of right pulmonary artery, left inferior pulmonary vein, coronary sinus, celiac axis, the orifice of superior mesenteric artery (SMA), the orifice of right real artery, the orifice of left renal artery and the orifice of inferior mesenteric artery were submitted to investigate the propagation of aortic dissection. The true lumen central angle was calculated in each level. The axial distance, branch angle difference and true distance between SMA and bilateral renal arteries were calculated. The trajectory of aortic dissection propagation from descending thoracic aorta to aortic bifurcation could be divided into two types of linear dissection type (n=41) and spiral dissection type (n=26). The latter were further subdivided into clockwise rotation type (n=14) and counter-clockwise rotation type (n=12). Younger age was significantly associated with the spiral dissection type as compared to older age (p=0.030). The spiral dissection type propagation pattern was found predominantly from the descending thoracic aorta to celiac axis, while at more distal levels linear type dissection was more common. The blood flow of SMA and celiac axis came from the true lumen or both lumens in all cases but single case from false lumen. The incidence (19.4%) of the right renal blood flow supplied from false lumen was lower than that (37.3%) of the left one supplied from false lumen. The shorter distance and the less angle difference between SMA and right renal artery than between SMA and left renal

  12. Evaluation of the anterior ethmoidal artery by 3D dual volume rotational digital subtraction angiography and native multidetector CT with multiplanar reformations. Initial findings.

    Science.gov (United States)

    Pandolfo, Ignazio; Vinci, Sergio; Salamone, Ignazio; Granata, Francesca; Mazziotti, Silvio

    2007-06-01

    Our purpose is to codify the anterior ethmoidal artery (AEA) course and its relationship with adjacent structures. Twenty patients with cerebrovascular disease underwent selective internal carotid dual volume angiography. Fusion of the vascular and bony images was obtained successively on a second console. MDCT of the cranium was performed in all patients. To identify the AEA course, multiplanar CT reformations were obtained. In all cases the entry-point of AEA and its course were identified by means of dual volume angiography. The information was confirmed by MDCT. In a second phase, we studied another 78 patients affected by inflammatory disease and polyposis only by means of MDCT, in order to confirm the previous data obtained by comparison between angiography and MDCT. In this second phase, 110/156 vessels were indirectly detected by means of visualization of the ethmoidal entry point. In the remaining cases, AEA was directly shown due to integrity of the thin ethmoidal bone lamellae or bony canal. Dual volume angiography is essential to identify the course of the AEA (standard of reference for the interpretation of CT). In patients with benign rhinosinusal pathology, where invasivity techniques are not justified, MPR reconstructions were of pivotal importance in the evaluation of the course of the artery with particular reference to its relationship with the frontal recess.

  13. Added value of CT perfusion compared to CT angiography in predicting clinical outcomes of stroke patients treated with mechanical thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Tsogkas, Ioannis; Knauth, Michael; Schregel, Katharina; Behme, Daniel; Psychogios, Marios Nikos [University Medicine Goettingen, Department of Neuroradiology, Goettingen (Germany); Wasser, Katrin; Maier, Ilko; Liman, Jan [University Medicine Goettingen, Department of Neurology, Goettingen (Germany)

    2016-11-15

    CTP images analyzed with the Alberta stroke program early CT scale (ASPECTS) have been shown to be optimal predictors of clinical outcome. In this study we compared two biomarkers, the cerebral blood volume (CBV)-ASPECTS and the CTA-ASPECTS as predictors of clinical outcome after thrombectomy. Stroke patients with thrombosis of the M1 segment of the middle cerebral artery were included in our study. All patients underwent initial multimodal CT with CTP and CTA on a modern CT scanner. Treatment consisted of full dose intravenous tissue plasminogen activator, when applicable, and mechanical thrombectomy. Three neuroradiologists separately scored CTP and CTA images with the ASPECTS score. Sixty-five patients were included. Median baseline CBV-ASPECTS and CTA-ASPECTS for patients with favourable clinical outcome at follow-up were 8 [interquartile range (IQR) 8-9 and 7-9 respectively]. Patients with poor clinical outcome showed a median baseline CBV-ASPECTS of 6 (IQR 5-8, P < 0.0001) and a median baseline CTA-ASPECTS of 7 (IQR 7-8, P = 0.18). Using CBV-ASPECTS and CTA-ASPECTS raters predicted futile reperfusions in 96 % and 56 % of the cases, respectively. CBV-ASPECTS is a significant predictor of clinical outcome in patients with acute ischemic stroke treated with mechanical thrombectomy. (orig.)

  14. Diagnosis and differential diagnosis of cerebro-vascular malformations by CT

    International Nuclear Information System (INIS)

    Schumacher, M.; Stoeter, P.; Voigt, K.

    1980-01-01

    In 38 patients, the diagnosis of a cerebrovascular malformation (17 arteriovenous angiomas including one low-flow- and two venous angiomas; 10 aneurysms; 4 arteriovenous fistulae of the cavernous sinus, the tentorium and one of the Great Vein of Galen; 6 megadolical basilar arteries) was initially made by computertomographic (CT) examination, including contrast enhancement. The characteristic and pathognomonic CT findings are described and compared with those of cerebral angiography also done in these cases. The problems of differential diagnosis and the reasons for a false CT diagnosis in 5 other patients with a cerebro-vascular malformation are investigated; and the diagnostic value of cerebral angiography and CT is discussed and their complementary functions are being pointed out. (orig.) 891 MG/orig. 892 MKO [de

  15. CT angiography - chest

    Science.gov (United States)

    ... your provider if you take the diabetes medication metformin (Glucophage). You may need to take extra precautions. ... Damage to kidneys from contrast dye CT scans use more radiation than regular x-rays. Having many ...

  16. Determining the haemodynamic significance of arterial stenosis: the relationship between CT angiography, computational fluid dynamics, and non-invasive fractional flow reserve

    International Nuclear Information System (INIS)

    Pang, C.L.; Alcock, R.; Pilkington, N.; Reis, T.; Roobottom, C.

    2016-01-01

    Coronary artery disease causes significant morbidity and mortality worldwide. Invasive coronary angiography (ICA) is currently the reference standard investigation. Fractional flow reserve (FFR) complements traditional ICA by providing extra information on blood flow, which has convincingly led to better patient management and improved cost-effectiveness. Computed tomography coronary angiography (CTCA) is suitable for the investigation of chest pain, especially in the low- and intermediate-risk groups. FFR generated using CT data (producing FFR_C_T) may improve the positive predictive value of CTCA. The basic science of FFR_C_T is like a “black box” to most imaging professionals. A fundamental principle is that good quality CTCA is likely to make any post-processing easier and more reliable. Both diagnostic and observational studies have suggested that the accuracy and the short-term outcome of using FFR_C_T are both comparable with FFR in ICA. More multidisciplinary research with further refined diagnostic and longer-term observational studies will hopefully pinpoint the role of FFR_C_T in existing clinical pathways.

  17. Dual Energy CT Angiography of Peripheral Arterial Disease: Feasibility of Using Lower Contrast Medium Volume.

    Directory of Open Access Journals (Sweden)

    Abdulrahman Almutairi

    Full Text Available One of the main drawbacks associated with Dual Energy Computed Tomography Angiography (DECTA is the risk of developing contrast medium-induced nephropathy (CIN. The aim of the present study was firstly, to design an optimal CT imaging protocol by determining the feasibility of using a reduced contrast medium volume in peripheral arterial DECTA, and secondly, to compare the results with those obtained from using routine contrast medium volume.Thirty four patients underwent DECTA for the diagnosis of peripheral arterial disease. They were randomly divided into two groups: Group 1 (routine contrast volume group with n = 17, injection rate 4-5 ml/s, and 1.5 ml/kg of contrast medium, and Group 2 ((low contrast volume group, with n = 17, injection rate 4-5ml/s, and contrast medium volume 0.75 ml/kg. A fast kilovoltage-switching 64-slice CT scanner in the dual-energy mode was employed for the study. A total of 6 datasets of monochromatic images at 50, 55, 60, 65, 70 and 75 keV levels were reconstructed with adaptive statistical iterative reconstruction (ASIR at 50%. A 4-point scale was the tool for qualitative analysis of results. The two groups were compared and assessed quantitatively for image quality on the basis of signal-to-noise ratio (SNR and contrast-to-noise-ratio (CNR. Radiation and contrast medium doses were also compared.The overall mean CT attenuation and mean noise for all lower extremity body parts was significantly lower for the low volume contrast group (p<0.001, and varied significantly between groups (p = 0.001, body parts (p<0.001 and keVs (p<0.001. The interaction between group body parts was significant with CT attenuation and CNR (p = 0.002 and 0.003 respectively, and marginally significant with SNR (p = 0.047, with minimal changes noticed between the two groups. Group 2 (low contrast volume group displayed the lowest image noise between 65 and 70 keV, recorded the highest SNR and CNR at 65 keV, and produced significantly lower

  18. Head-to-head comparison between {sup 18}F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela [University Hospitals of Strasbourg, Department of Radiology, Strasbourg (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Goichot, Bernard; Chabrier, Gerard [University Hospitals of Strasbourg, Department of Internal Medicine, Strasbourg (France); Petit-Thomas, Julie; Charpiot, Anne [University Hospitals of Strasbourg, Department of Otolaryngology and Maxillofacial Surgery, Strasbourg (France); Averous, Gerlinde [University Hospitals of Strasbourg, Department of Pathology, Strasbourg (France); Imperiale, Alessio [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Hautepierre University Hospital, Biophysics and Nuclear Medicine, Strasbourg Cedex (France)

    2017-06-15

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of {sup 18}F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both {sup 18}F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further {sup 18}F-FDOPA PET/CT and/or MRA. {sup 18}F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. {sup 18}F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. {sup 18}F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, {sup 18}F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. {sup 18}F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that {sup 18}F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when {sup 68

  19. Head-to-head comparison between "1"8F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    International Nuclear Information System (INIS)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques; Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela; Taieb, David; Goichot, Bernard; Chabrier, Gerard; Petit-Thomas, Julie; Charpiot, Anne; Averous, Gerlinde; Imperiale, Alessio

    2017-01-01

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of "1"8F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both "1"8F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further "1"8F-FDOPA PET/CT and/or MRA. "1"8F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. "1"8F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. "1"8F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, "1"8F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. "1"8F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that "1"8F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when "6"8Ga-labeled somatostatin analogues are

  20. Perfusion CT in acute stroke

    International Nuclear Information System (INIS)

    Eckert, Bernd; Roether, Joachim; Fiehler, Jens; Thomalla, Goetz

    2015-01-01

    Modern multislice CT scanners enable multimodal protocols including non-enhanced CT, CT angiography, and CT perfusion. A 64-slice CT scanner provides 4-cm coverage. To cover the whole brain, a 128 - 256-slice scanner is needed. The use of perfusion CT requires an optimized scan protocol in order to reduce exposure to radiation. As compared to non-enhanced CT and CT angiography, the use of CT perfusion increases detection rates of cerebral ischemia, especially small cortical ischemic lesions, while the detection of lacunar and infratentorial stroke lesions remains limited. Perfusion CT enables estimation of collateral flow in acute occlusion of large intra- or extracranial arteries. Currently, no established reliable thresholds are available for determining infarct core and penumbral tissue by CT perfusion. Moreover, perfusion parameters depend on the processing algorithms and the software used for calculation. However, a number of studies point towards a reduction of cerebral blood volume (CBV) below 2 ml/100 g as a critical threshold that identifies infarct core. Large CBV lesions are associated with poor outcome even in the context of recanalization. The extent of early ischemic signs on non-enhanced CT remains the main parameter from CT imaging to guide acute reperfusion treatment. Nevertheless, perfusion CT increases diagnostic and therapeutic certainty in the acute setting. Similar to stroke MRI, perfusion CT enables the identification of tissue at risk of infarction by the mismatch between infarct core and the larger area of critical hypoperfusion. Further insights into the validity of perfusion parameters are expected from ongoing trials of mechanical thrombectomy in stroke.

  1. Characteristics of coronary artery disease in symptomatic type 2 diabetic patients: evaluation with CT angiography

    Directory of Open Access Journals (Sweden)

    Zhu Zhi-yu

    2010-11-01

    Full Text Available Abstract Background Coronary artery disease (CAD is a common and severe complication of type 2 diabetes mellitus (DM. The aim of this study is to identify the features of CAD in diabetic patients using coronary CT angiography (CTA. Methods From 1 July 2009 to 20 March 2010, 113 consecutive patients (70 men, 43 women; mean age, 68 ± 10 years with type 2 DM were found to have coronary plaques on coronary CTA. Their CTA data were reviewed, and extent, distribution and types of plaques and luminal narrowing were evaluated and compared between different sexes. Results In total, 287 coronary vessels (2.5 ± 1.1 per patient and 470 segments (4.2 ± 2.8 per patient were found to have plaques, respectively. Multi-vessel disease was more common than single vessel disease (p p p p p = 0.855. Extent of CAD, types of plaques and luminal narrowing were not significantly different between male and female diabetic patients. Conclusions Coronary CTA depicted a high plaque burden in patients with type 2 DM. Plaques, which were mainly calcified, were more frequently detected in the proximal segment of the LAD artery, and increased attention should be paid to the significant prevalence of obstructive stenosis. In addition, DM reduced the sex differential in CT findings of CAD.

  2. Calcified Plaque of Coronary Artery: Factors Influencing Overestimation of Coronary Artery Stenosis on Coronary CT Angiography

    International Nuclear Information System (INIS)

    Kim, Mok Hee; Kim, Yun Hyeon; Choi, Song; Seon, Hyun Ju; Jeong, Gwang Woo; Park, Jin Gyoon; Kang, Heoung Keun; Ko, Joon Seok

    2010-01-01

    To assess the influence of calcified plaque characteristics on the overestimation of coronary arterial stenosis on a coronary CT angiography (CCTA). The study included 271 coronary arteries with calcified plaques identified by CCTA, and based on 928 coronary arteries from 232 patients who underwent both CCTA and invasive coronary angiography (ICA). Individual coronary arteries were classified into two groups by agreement based on the degree of stenosis from each CCTA and ICA: 1) group A includes patients with concordant CCTA and ICA results and, 2) group B includes patients with an overestimation of CCTA compared to ICA. Parameters including total calcium score, calcium score of an individual coronary artery, calcium burden number of an individual coronary artery, and the density of each calcified plaque (calcium score / number of calcium burden) for each individual coronary artery were compared between the two groups. Of the 271 coronary arteries, 164 (60.5%) were overestimated on CCTA. The left anterior descending artery (LAD) had a significantly low rate of overestimation (47.1%) compared to the other coronary arteries (p=0.001). No significant differences for total calcium score, calcium score of individual coronary artery, and the density of each calcified plaque from individual coronary arteries between two groups was observed. However, a decreasing tendency for the rate of overestimation on CCTA was observed with an increase in calcium burden of individual coronary arteries (p<0.05). The evaluation of coronary arteries suggests that the degree of coronary arterial stenosis had a tendency to be overestimated by calcified plaques on CCTA. However, the rate of overestimation for the degree of coronary arterial stenosis by calcified plaques was not significantly influenced by total calcium score, calcium score of individual coronary artery, and density of each calcified plaque

  3. Focal changes of the spleen in one case of Gaucher disease - assessed by ultrasonography, CT, MRI and angiography

    International Nuclear Information System (INIS)

    Aspestrand, F.; Charania, B.; Scheel, B.; Kolmannskog, F.; Jacobsen, M.

    1989-01-01

    Focal lesions of the spleen in one case of Gaucher disease are demonstrated by ultrasonography, CT, MRI and angiography. The sonographic and angiographic features differ from the findings presented in previous reports. The Gaucher manifestations in the spleen as demonstrated by CT, do not seem to have been reported previously. An earlier report on the MR findings in the liver and spleen in this disease did not disclose any focal abnormalities. In this case, ultrasonography and MRI revealed a targetlike configuration of the focal lesions. An attempt is made to analyze the more complex patterns disclosed by MRI against the background of the manifestations by the other imaging modalities and previous reports. (orig.) [de

  4. [Study of CT Automatic Exposure Control System (CT-AEC) Optimization in CT Angiography of Lower Extremity Artery by Considering Contrast-to-Noise Ratio].

    Science.gov (United States)

    Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki

    2016-01-01

    To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.

  5. Iterative model reconstruction: Improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Oda, Seitaro, E-mail: seisei0430@nifty.com [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States); Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto University, 1-1-1 Honjyo, Chuo-ku, Kumamoto, 860-8556 (Japan); Weissman, Gaby, E-mail: Gaby.Weissman@medstar.net [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States); Vembar, Mani, E-mail: mani.vembar@philips.com [CT Clinical Science, Philips Healthcare, c595 Miner Road, Cleveland, OH 44143 (United States); Weigold, Wm. Guy, E-mail: Guy.Weigold@MedStar.net [Department of Cardiology, MedStar Washington Hospital Center, 110 Irving Street, NW, Washington, DC 20010 (United States)

    2014-08-15

    Objectives: To investigate the effects of a new model-based type of iterative reconstruction (M-IR) technique, the iterative model reconstruction, on image quality of prospectively gated coronary CT angiography (CTA) acquired at low-tube-voltage. Methods: Thirty patients (16 men, 14 women; mean age 52.2 ± 13.2 years) underwent coronary CTA at 100-kVp on a 256-slice CT. Paired image sets were created using 3 types of reconstruction, i.e. filtered back projection (FBP), a hybrid type of iterative reconstruction (H-IR), and M-IR. Quantitative parameters including CT-attenuation, image noise, and contrast-to-noise ratio (CNR) were measured. The visual image quality, i.e. graininess, beam-hardening, vessel sharpness, and overall image quality, was scored on a 5-point scale. Lastly, coronary artery segments were evaluated using a 4-point scale to investigate the assessability of each segment. Results: There was no significant difference in coronary arterial CT attenuation among the 3 reconstruction methods. The mean image noise of FBP, H-IR, and M-IR images was 29.3 ± 9.6, 19.3 ± 6.9, and 12.9 ± 3.3 HU, respectively, there were significant differences for all comparison combinations among the 3 methods (p < 0.01). The CNR of M-IR was significantly better than of FBP and H-IR images (13.5 ± 5.0 [FBP], 20.9 ± 8.9 [H-IR] and 39.3 ± 13.9 [M-IR]; p < 0.01). The visual scores were significantly higher for M-IR than the other images (p < 0.01), and 95.3% of the coronary segments imaged with M-IR were of assessable quality compared with 76.7% of FBP- and 86.9% of H-IR images. Conclusions: M-IR can provide significantly improved qualitative and quantitative image quality in prospectively gated coronary CTA using a low-tube-voltage.

  6. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  7. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  8. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  9. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  10. Assessment of Myocardial Bridge and Mural Coronary Artery Using ECG-Gated 256-Slice CT Angiography: A Retrospective Study

    Directory of Open Access Journals (Sweden)

    En-sen Ma

    2013-01-01

    Full Text Available Recent clinical reports have indicated that myocardial bridge and mural coronary artery complex (MB-MCA might cause major adverse cardiac events. 256-slice CT angiography (256-slice CTA is a newly developed CT system with faster scanning and lower radiation dose compared with other CT systems. The objective of this study is to evaluate the morphological features of MB-MCA and determine its changes from diastole to systole phase using 256-slice CTA. The imaging data of 2462 patients were collected retrospectively. Two independent radiologists reviewed the collected images and the diagnosis of MB-MCA was confirmed when consistency was obtained. The length, diameter, and thickness of MB-MCA in diastole and systole phases were recorded, and changes of MB-MCA were calculated. Our results showed that among the 2462 patients examined, 336 have one or multiple MB-MCA (13.6%. Out of 389 MB-MCA segments, 235 sites were located in LAD2 (60.41%. The average diameter change of MCA in LAD2 from systole phase to diastole phase was  mm, and 34.9% of MCA have more than 50% diameter stenosis in systole phase. This study suggested that 256-slice CTA multiple-phase reconstruction technique is a reliable method to determine the changes of MB-MCA from diastole to systole phase.

  11. Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography

    International Nuclear Information System (INIS)

    Seifarth, Harald; Puesken, Michael; Wienbeck, Susanne; Wessling, Johannes; Maintz, David; Heindel, Walter; Juergens, Kai-Uwe; Kalafut, John F.

    2009-01-01

    The aim of this study was to determine whether individually tailored protocols for the injection of contrast medium (CM) result in higher and more homogeneous vascular attenuation throughout the coronary arteries at coronary CT angiography compared with conventional injection protocols using fixed injection parameters. Of 120 patients included in the study, 80 patients were randomized into two groups. Group 1 received 80 mL of CM at 6 mL/s. For group 2 injection parameters were individually adjusted to patient weight, the duration of CT data acquisition, and attenuation parameters following a test bolus. In the control group (group 3) the volume of CM was adjusted to the duration of CT data acquisition and injected at 5 mL/s. Attenuation was measured in the proximal, middle, and distal right coronary artery (RCA), in the proximal and middle left anterior descending artery (LAD), and in cranial and caudal sections of both ventricles. Patient parameters, scan delay, and scan duration did not differ significantly between the groups. Mean CM volume was 82.5 mL (flow rate 5.1 mL/s) in group 2 and 73.5 mL in group 3. Attenuation in both RCA and LAD was significantly higher for group 2 vs. group 3 (RCA: 414.9(±49.9)-396.1(±52.1) HU vs. 366.0(±64.3)-341.6(±72.5) HU; LAD: 398.9(±48.6)-364.6(±44.6) HU vs. 356.3(±69.5)-323.0(±67.2) HU). For group 1 vs. group 2 only attenuation in the distal RCA differed significantly: 396.1(±52.1) vs. 370.7(±70.5) HU. Individually tailored CM injection protocols yield higher attenuation, especially in the distal segments of the coronary vessels, compared with injection protocols using fixed injection parameters. (orig.)

  12. Cirsoid Aneurysm of Coronary Arteries Associated with Arterioventricular Fistula Evaluated by 64-Multidetector CT Coronary Angiography: Depiction of a Case

    International Nuclear Information System (INIS)

    Marrone, Gianluca; Mamone, Giuseppe; Milazzo, Mariapina; Caruso, Settimo; Baravoglia, Cesar Hernandez; Vitulo, Patrizio; Gridelli, Bruno; Luca, Angelo

    2009-01-01

    A female patient with severe pulmonary hypertension was admitted for lung transplant evaluation. As an incidental finding, the chest CT showed diffuse and dilated coronaries, not detected at previous echocardiography. A coronary CT angiography was then performed using a 64-multidetector computed tomography (MDCT) scanner to better evaluate the coronary tree. The images obtained after postprocessing demonstrated tremendously aneurysmatic and tortuous coronary arteries and the presence of a septal branch deepening into the myocardium and penetrating the right ventricle cavity, forming an abnormal arterioventricular fistula. A causal relation between the aneurysms and the fistula is suspected.

  13. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  14. Diagnostic accuracy of dual-source CT coronary angiography in patients with atrial fibrillation: Meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Zhi-wei [Department of Health Statistics, School of Public Health, Fourth Military Medical University, No. 169, Changle West Road, Xi’an, Shaanxi 710032 (China); Xu, Lin [Department of Medical Cardiology, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui; Ding, Juan; Li, Li [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jin, Zhi-tao [Department of Cardiology, General Hospital of the Second Artillery, Beijing 100088 (China)

    2013-10-01

    Rationale and objective: To synthesize the available data to underscore the diagnostic accuracy of dual-source CT (DSCT) coronary angiography in patients with atrial fibrillation (AF). Materials and methods: We searched in the electronic databases of PubMed for all published studies that examined patients with AF using DSCT. We used an exact binomial rendition of the bivariate mixed-effects regression model to synthesize the diagnostic data. Results: The positive and negative likelihood ratios (LRs) at the patient level were 6.0 (CI, 3.6–10.1) and 0.03(CI, 0.004–0.2), respectively. The negative predictive values higher than 90% were available for a CAD prevalence <78%. The pooled vessel- and segment-level estimates showed higher positive and negative LRs than the patient-level estimates (15.3 [CI, 9.8–23.9] and 0.1 [CI, 0.07–0.3]; 25.1 [CI, 10.8–58.5] and 0.2 [CI, 0.2–0.3], respectively). No statistically significant heterogeneity between studies and publication bias were found at the patient level estimate. A sensitivity analysis showed that no study influenced the pooled results larger than 0.02. Conclusions: Cardiac angiography with DSCT can be applied as an imaging test for ruling out CAD in patient with AF. However, DSCT angiography may be not an effective tool for risk stratification for the high negative LR at the artery and segment levels.

  15. Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Rihyeon; Park, Eun-Ah; Lee, Whal; Chung, Jin Wook [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2016-11-15

    To assess the image quality and diagnostic accuracy of 320-row area detector CT (320-ADCT) coronary angiography using 40 mL of contrast material in comparison with 60-mL protocol. This retrospective study included 183 patients who underwent 320-ADCT coronary angiography using 40 mL of contrast and additional 183 sex- and body mass index-matched patients using 60 mL of contrast constituting the control group. Both groups used the same 5-mL/sec injection rate. Quantitative image quality measurements and diagnostic accuracies were calculated and compared. Mean attenuation and contrast-to-noise ratio (CNR) at the aorta and all coronary arteries were lower in the 40-mL group than in the 60-mL group (all, p < 0.05), except for the CNR at proximal coronary arteries at 100 kVp (p = 0.073). However, the proportion of coronary segments with vessel attenuation >250 HU was not different between groups (all, p > 0.05), except for distal coronary arteries at 80 kVp (p = 0.001). Furthermore, there were no differences in per-patient and per-segment diagnostic accuracies between the groups (all, p > 0.05). 320-ADCT coronary angiography using 40 mL of contrast showed image quality and diagnostic accuracy comparable to the 60-mL protocol, demonstrating the clinical feasibility of lowering the risk of contrast-induced nephropathy through contrast volume reduction. (orig.)

  16. CT versus MR Techniques in the Detection of Cervical Artery Dissection.

    Science.gov (United States)

    Hanning, Uta; Sporns, Peter B; Schmiedel, Meilin; Ringelstein, Erich B; Heindel, Walter; Wiendl, Heinz; Niederstadt, Thomas; Dittrich, Ralf

    2017-11-01

    Spontaneous cervical artery dissection (sCAD) is an important etiology of juvenile stroke. The gold standard for the diagnosis of sCAD is convential angiography. However, magnetic resonance imaging (MRI)/MR angiography (MRA) and computed tomography (CT)/CT angiography (CTA) are frequently used alternatives. New developments such as multislice CT/CTA have enabled routine acquisition of thinner sections with rapid imaging times. The goal of this study was to compare the capability of recent developed 128-slice CT/CTA to MRI/MRA to detect radiologic features of sCAD. Retrospective review of patients with suspected sCAD (n = 188) in a database of our Stroke center (2008-2014), who underwent CT/CTA and MRI/MRA on initial clinical work-up. A control group of 26 patients was added. All Images were evaluated concerning specific and sensitive radiological features for dissection by two experienced neuroradiologists. Imaging features were compared between the two modalities. Forty patients with 43 dissected arteries received both modalities (29 internal carotid arteries [ICAs] and 14 vertebral arteries [VAs]). All CADs were identified in CT/CTA and MRI/MRA. The features intimal flap, stenosis, and lumen irregularity appeared in both modalities. One high-grade stenosis was identified by CT/CTA that was expected occluded on MRI/MRA. Two MRI/MRA-confirmed pseudoaneurysms were missed by CT/CTA. None of the controls evidenced specific imaging signs for dissection. CT/CTA is a reliable and better available alternative to MRI/MRA for diagnosis of sCAD. CT/CTA should be used to complement MRI/MRA in cases where MRI/MRA suggests occlusion. Copyright © 2017 by the American Society of Neuroimaging.

  17. Perfusion CT in childhood stroke—Initial observations and review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Zebedin, D., E-mail: doris.zebedin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria); Sorantin, E.; Riccabona, M. [Division of Pediatric Radiology, Department of Radiology, University Hospital LKH Graz (Austria)

    2013-07-15

    Introduction: To report the preliminary results of contrast-enhanced perfusion multi-detector CT for diagnoses of perfusion disturbances in children with clinical suspicion of stroke. Patients and methods: Within the last two years emergency perfusion CT was performed in ten children (age: 8–17 years, male:female = 3:7) for assessment of suspected childhood stroke. These intracranial perfusion CT, intracranial CT-digital subtraction angiography (CT-DSA) and extracranial CT-angiography (CTA) studies were retrospectively reviewed and compared with MRI, follow-up CT, catheter angiography and final clinical diagnosis. The total dose length product (DLP) for the entire examination was recorded. The image quality of perfusion CT-maps, CT-DSA and CTA were evaluated with a subjective three-point scale ranging from very good to non-diagnostic image quality rating perfusion disturbance, intracranial peripheral vessel depiction, and motion- or streak artifacts. Results: In nine of ten children perfusion CT showed no false positive or false negative results. In one of ten children suffering from migraine focal hypo-perfusion was read as perfusion impairment potentially indicating early stroke, but MRI and MRA follow-up were negative. Overall, perfusion-CT with CT-DSA was rated very good in 80% of cases for the detection of perfusion disturbances and vessel anatomy. Conclusions: In comparison to standard CT, contrast-enhanced perfusion CT improves CTs’ diagnostic capability in the emergency examination of children with a strong suspicion of ischemic cerebral infarction.

  18. SU-E-I-25: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Simulation Study

    International Nuclear Information System (INIS)

    Johnson, T; Ding, H; Lipinski, J; Molloi, S

    2015-01-01

    Purpose: To develop a physics-based model for accurate quantification of the cross-sectional area (CSA) of coronary arteries in CT angiography by measuring the integrated density to account for the partial volume effect. Methods: In this technique the integrated density of the object as compared with its local background is measured to account for the partial volume effect. Normal vessels were simulated as circles with diameters in the range of 0.1–3mm. Diseased vessels were simulated as 2, 3, and 4mm diameter vessels with 10–90% area stenosis, created by inserting circular plaques. A simplified two material model was used with the lumen as 8mg/ml Iodine and background as lipid. The contrast-to-noise ratio between lumen and background was approximately 26. Linear fits to the known CSA were calculated. The precision and accuracy of the measurement were quantified using the root-mean-square fit deviations (RMSD) and errors to the known CSA (RMSE). Results compared to manual segmentation of the vessel lumen. To assess the impact of random variations, coefficients of variation (CV) from 10 simulations for each vessel were computed to determine reliability. Measurements with CVs less than 10% were considered reliable. Results: For normal vessels, the precision and accuracy of the integrated density technique were 0.12mm 2 and 0.28mm 2 , respectively. The corresponding results for manual segmentation were 0.27mm 2 and 0.43mm 2 . For diseased vessels, the precision and accuracy of the integrated density technique were 0.14mm 2 and 0.19mm 2 . Corresponding results for manual segmentation were 0.42mm 2 and 0.71mm 2 . Reliable CSAs were obtained for normal vessels with diameters larger than 1 mm and for diseased vessels with area as low as 1.26mm2. Conclusion: The CSA based on integrated density showed improved precision and accuracy as compared with manual segmentation in simulation. These results indicate the potential of using integrated density to quantify CSA of

  19. Estimation of intrathoracic arterial diameter by means of computed tomographic angiography in Hispaniolan Amazon parrots.

    Science.gov (United States)

    Beaufrère, Hugues; Rodriguez, Daniel; Pariaut, Romain; Gaschen Dvm, Lorrie; Schnellbacher, Rodney; Nevarez, Javier G; Tully, Thomas N

    2011-02-01

    To establish a computed tomography (CT)-angiography protocol and measure the diameters of major arteries in parrots. 13 Hispaniolan Amazon parrots (Amazona ventralis). 16-slice CT scanning was used to measure the apparent diameter of the ascending aorta, abdominal aorta, pulmonary arteries, and brachiocephalic trunk. Before scanning, all birds underwent ECG and echocardiographic assessment and were considered free of detectable cardiovascular diseases. Each bird was anesthetized, and a precontrast helical CT scan was performed. Peak aortic enhancement was established with a test bolus technique via dynamic axial CT scan over a predetermined single slice. An additional bolus of contrast medium was then injected, and a helical CT-angiography scan was performed immediately afterward. Arterial diameter measurements were obtained by 2 observers via various windows before and after injection, and intra- and interobserver agreement was assessed. Reference limits were determined for arterial diameter measurements before and after contrast medium administration in pulmonary, mediastinal, and manual angiography windows. Ratios of vertebral body diameter to keel length were also calculated. Intraobserver agreement was high (concordance correlation coefficients ≥ 0.95); interobserver agreement was medium to high (intraclass correlation coefficients ≥ 0.65). CT-angiography was safe and is of potential diagnostic value in parrots. We recommend performing the angiography immediately after IV injection of 3 mL of iohexol/kg. Arterial diameter measurements at the described locations were reliable.

  20. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...

  1. Correlation of Color Doppler with Multidetector CT Angiography Findings in Carotid Artery Stenosis

    Directory of Open Access Journals (Sweden)

    Živorad N. Savic

    2010-01-01

    Full Text Available The aim of this paper was to examine the correlation between the Color Doppler ultrasound (CD-US and multidetector CT angiography (MDCTA diagnostic methods, and to define the degree and extent of stenosis in patients with internal carotid artery stenosis. This was a cross-sectional study with a consecutive series of patients. All US examinations were always carried out by the same physician-angiologist, while all CT examinations were always carried out by the same physician-radiologist. Both worked independently from each other. The stenosis area was measured at the narrowest point by NASCET criteria for US/CT. Peak systolic velocity (PSV over 210 cm/sec and end diastolic velocity (EDV over 110 cm/sec criteria were applied for stenoses with lumen narrowed over 70%, while PSV under 130 cm/sec and EDV under 100 cm/sec criteria were applied for those with lumen narrowed under 70%. A total of 124 carotid arteries were observed; namely, 89 narrowed and 68 surgically treated. All patients were reviewed by US and then by MDCTA; patients with 70–99% stenosis underwent surgery. The correlation coefficient between stenosis degree measured by US and MDCTA was 0.922; p 0.05. The US and CT matching level for stenoses from 70 to 99% was very high (κ = 0.778, p < 0.01. In conclusion, there is a highly significant statistical correlation among both diagnostic methods when measuring stenosis degree and extent. US is more dependent on the physician, while MDCTA is more objective and independent from the physician. We think it would be appropriate to undertake an MDCTA exam for those patients who are candidates for carotid endarterectomy.

  2. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    International Nuclear Information System (INIS)

    Hacker, M.; Hack, N.; Tiling, R.; Jakobs, T.; Nikolaou, K.; Becker, C.; Ziegler, F. von; Knez, A.; Koenig, A.; Klauss, V.

    2007-01-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 ± 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  3. Combined use of 64-slice computed tomography angiography and gated myocardial perfusion SPECT for the detection of functionally relevant coronary artery stenoses. First results in a clinical setting concerning patients with stable angina

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M.; Hack, N.; Tiling, R. [Klinikum Grosshadern (Germany). Dept. of Nuclear Medicine; Jakobs, T.; Nikolaou, K.; Becker, C. [Klinikum Grosshadern (Germany). Dept. of Clinical Radiology; Ziegler, F. von; Knez, A. [Klinikum Grosshadern (Germany). Dept. of Cardiology; Koenig, A.; Klauss, V. [Medizinische Poliklinik-Innenstadt, Univ. of Munich (Germany). Dept. of Cardiology

    2007-07-01

    Aim: In patients with stable angina pectoris both morphological and functional information about the coronary artery tree should be present before revascularization therapy is performed. High accuracy was shown for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to invasive coronary angiography (ICA) in detecting ''obstructive'' coronary artery disease (CAD). Gated myocardial SPECT (MPI) is an established method for the noninvasive assessment of functional significance of coronary stenoses. Aim of the study was to evaluate the combination of 64-slice CT angiography plus MPI in comparison to ICA plus MPI in the detection of hemodynamically relevant coronary artery stenoses in a clinical setting. Patients, methods: 30 patients (63 {+-} 10.8 years, 23 men) with stable angina (21 with suspected, 9 with known CAD) were investigated. MPI, 64-slice CT angiography and ICA were performed, reversible and fixed perfusion defects were allocated to determining lesions separately for MDCT angiography and ICA. The combination of MDCT angiography plus MPI was compared to the results of ICA plus MPI. Results: Sensitivity, specificity, negative and positive predictive value for the combination of MDCT angiography plus MPI was 85%, 97%, 98% and 79%, respectively, on a vessel-based and 93%, 87%, 93% and 88%, respectively, on a patient-based level. 19 coronary arteries with stenoses =50% in both ICA and MDCT angiography showed no ischemia in MPI. Conclusion: The combination of 64-slice CT angiography and gated myocardial SPECT enabled a comprehensive non-invasive view of the anatomical and functional status of the coronary artery tree. (orig.)

  4. High-resolution ex vivo magnetic resonance angiography: a feasibility study on biological and medical tissues

    Directory of Open Access Journals (Sweden)

    Boel Lene WT

    2010-03-01

    Full Text Available Abstract Background In biomedical sciences, ex vivo angiography is a practical mean to elucidate vascular structures three-dimensionally with simultaneous estimation of intravascular volume. The objectives of this study were to develop a magnetic resonance (MR method for ex vivo angiography and to compare the findings with computed tomography (CT. To demonstrate the usefulness of this method, examples are provided from four different tissues and species: the human placenta, a rice field eel, a porcine heart and a turtle. Results The optimal solution for ex vivo MR angiography (MRA was a compound containing gelatine (0.05 g/mL, the CT contrast agent barium sulphate (0.43 mol/L and the MR contrast agent gadoteric acid (2.5 mmol/L. It was possible to perform angiography on all specimens. We found that ex vivo MRA could only be performed on fresh tissue because formalin fixation makes the blood vessels permeable to the MR contrast agent. Conclusions Ex vivo MRA provides high-resolution images of fresh tissue and delineates fine structures that we were unable to visualise by CT. We found that MRA provided detailed information similar to or better than conventional CTA in its ability to visualize vessel configuration while avoiding interfering signals from adjacent bones. Interestingly, we found that vascular tissue becomes leaky when formalin-fixed, leading to increased permeability and extravascular leakage of MR contrast agent.

  5. New possibilities in the diagnosis of ischemia. CT-FFR and CT-Perfusion; Neue Moeglichkeiten der Ischaemiediagnostik. CT-FFR und CT-Perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Lehmkuhl, Lukas [Herz- und Gefaessklinik, Bad Neustadt an der Saale (Germany). Abt. fuer Radiologie; Krieghoff, Christian [Herzzentrum Leipzig (Germany); Gutberlet, Matthias [Herzzentrum Leipzig (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie; Leipzig Univ. (Germany). Kardiologische Bildgebung

    2017-12-15

    Coronary CT-angiography (CCTA) plays an increasing role in the primary diagnostics of coronary artery disease (CAD) according to the present guidelines but also in clinical reality. The sensitivity and negative predictive value of CCTA is very high, but the specificity could still be improved. Newer techniques to assess myocardial ischemia like CT-FFR and CT-Perfusion may help to achieve that goal.

  6. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  7. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Zhou, Chang Sheng; Zhao, Yan E.; Li, Xie; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Wang, Yining; Cao, Jian; Jin, Zhengyu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Schoepf, U.J. [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Gong, Jian Bin [Jinling Hospital, Medical School of Nanjing University, Department of Cardiology, Nanjing, Jiangsu (China)

    2016-03-15

    To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50 % stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. At CCTA, 94.3 % (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100 % and 93.0 % on a per-patient basis. Per-vessel and per-segment performances were 92.2 % and 89.5 %; 79.5 % and 88.3 %, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. (orig.)

  8. Vascular diameter measurement in CT angiography: comparison of model-based iterative reconstruction and standard filtered back projection algorithms in vitro.

    Science.gov (United States)

    Suzuki, Shigeru; Machida, Haruhiko; Tanaka, Isao; Ueno, Eiko

    2013-03-01

    The purpose of this study was to evaluate the performance of model-based iterative reconstruction (MBIR) in measurement of the inner diameter of models of blood vessels and compare performance between MBIR and a standard filtered back projection (FBP) algorithm. Vascular models with wall thicknesses of 0.5, 1.0, and 1.5 mm were scanned with a 64-MDCT unit and densities of contrast material yielding 275, 396, and 542 HU. Images were reconstructed images by MBIR and FBP, and the mean diameter of each model vessel was measured by software automation. Twenty separate measurements were repeated for each vessel, and variance among the repeated measures was analyzed for determination of measurement error. For all nine model vessels, CT attenuation profiles were compared along a line passing through the luminal center on axial images reconstructed with FBP and MBIR, and the 10-90% edge rise distances at the boundary between the vascular wall and the lumen were evaluated. For images reconstructed with FBP, measurement errors were smallest for models with 1.5-mm wall thickness, except those filled with 275-HU contrast material, and errors grew as the density of the contrast material decreased. Measurement errors with MBIR were comparable to or less than those with FBP. In CT attenuation profiles of images reconstructed with MBIR, the 10-90% edge rise distances at the boundary between the lumen and vascular wall were relatively short for each vascular model compared with those of the profile curves of FBP images. MBIR is better than standard FBP for reducing reconstruction blur and improving the accuracy of diameter measurement at CT angiography.

  9. Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose

    Energy Technology Data Exchange (ETDEWEB)

    Menke, Jan [University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany); Kowalski, Joerg [Dr. Lauterbach-Klinik, Department of Cardiology, Bad Liebenstein (Germany)

    2016-02-15

    To meta-analyze diagnostic accuracy, test yield and utility of coronary computed tomography angiography (CCTA) in coronary artery disease (CAD) by an intention-to-diagnose approach with inclusion of unevaluable results. Four databases were searched from 1/2005 to 3/2013 for prospective studies that used 16-320-row or dual-source CTs and provided 3 x 2 patient-level data of CCTA (positive, negative, or unevaluable) versus catheter angiography (positive or negative) for diagnosing ≥50 % coronary stenoses. A Bayesian multivariate 3 x 2 random-effects meta-analysis considered unevaluable CCTAs. Thirty studies (3422 patients) were included. Compared to 16-40 row CT, test yield and accuracy of CCTA has significantly increased with ≥64-row CT (P < 0.05). In ≥64-row CT, about 2.5 % (95 %-CI, 0.9-4.8 %) of diseased patients and 7.5 % (4.5-11.2 %) of non-diseased patients had unevaluable CCTAs. A positive likelihood ratio of 8.9 (6.1-13.5) indicated moderate suitability for identifying CAD. A negative likelihood ratio of 0.022 (0.01-0.04) indicated excellent suitability for excluding CAD. Unevaluable CCTAs had an equivocal likelihood ratio of 0.42 (0.22-0.71). In the utility analysis, CCTA was useful at intermediate pre-test probabilities (16-70 %). CCTA is useful at intermediate CAD pre-test probabilities. Positive CCTAs require verification to confirm CAD, unevaluable CCTAs require alternative diagnostics, and negative CCTAs exclude obstructive CAD with high certainty. (orig.)

  10. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  11. Benefit of cone-beam computed tomography angiography in acute management of angiographically undetectable ruptured arteriovenous malformations.

    Science.gov (United States)

    Rahal, Jason P; Malek, Adel M

    2013-10-01

    Ruptured arteriovenous malformations (AVMs) are a frequent cause of intracerebral hemorrhage (ICH). In some cases, compression from the associated hematoma in the acute setting can partially or completely occlude an AVM, making it invisible on conventional angiography techniques. The authors report on the successful use of cone-beam CT angiography (CBCT-A) to precisely identify the underlying angioarchitecture of ruptured AVMs that are not visible on conventional angiography. Three patients presented with ICH for which they underwent examination with CBCT-A in addition to digital subtraction angiography and other imaging modalities, including MR angiography and CT angiography. All patients underwent surgical evacuation due to mass effect from the hematoma. Clinical history, imaging studies, and surgical records were reviewed. Hematoma volumes were calculated. In all 3 cases, CBCT-A demonstrated detailed anatomy of an AVM where no lesion or just a suggestion of a draining vein had been seen with other imaging modalities. Magnetic resonance imaging demonstrated enhancement in 1 patient; CT angiography demonstrated a draining vein in 1 patient; 2D digital subtraction angiography and 3D rotational angiography demonstrated a suggestion of a draining vein in 2 cases and no finding in the third. In the 2 patients in whom CBCT-A was performed prior to surgery, the demonstrated AVM was successfully resected without evidence of a residual lesion. In the third patient, CBCT-A allowed precise targeting of the AVM nidus using Gamma Knife radiosurgery. Cone-beam CT angiography should be considered in the evaluation and subsequent treatment of ICH due to ruptured AVMs. In cases in which the associated hematoma compresses the AVM nidus, CBCT-A can have higher sensitivity and anatomical accuracy than traditional angiographic modalities, including digital subtraction angiography.

  12. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  13. Usefulness of computed tomography angiography for the detection of high-risk aortas for carotid artery stenting

    International Nuclear Information System (INIS)

    Yamamoto, Hiromichi; Kuwayama, Naoya; Hayashi, Nakamasa; Kubo, Michiya; Endo, Shunro

    2011-01-01

    This study evaluated the usefulness of computed tomography (CT) angiography for the detection of high-risk aortas for carotid artery stenting (CAS). We investigated changes in the treatment method and modifications of endovascular techniques according to the information from CT angiography. CT angiography using three-dimensional and multi-planar reconstruction was performed in 43 consecutive patients with carotid artery stenoses intended to undergo CAS. Two neurosurgeons evaluated the images and estimated the risk and difficulties of CAS. CT angiography clearly depicted the entire aorta, the supra-aortic vessels, and the ilio-femoral arteries in all patients. Abnormal vascular findings were found in 17 patients. High-risk aortic lesions for CAS were detected in 5 patients, including thick aortic plaques with thrombi in 2. We changed the treatment strategy from CAS to carotid endarterectomy (CEA) in these 2 patients. CT angiograms proved very useful in evaluating the approach routes of CAS in 12 patients. One patient had dissecting aneurysm of the thoracic aorta and another had aberrant right vertebral artery. In these two, the treatment strategy was changed from CAS to CEA. The treatment method was changed in 4 patients in total. CT angiography is useful for the detection of high-risk aortas for CAS and for the evaluation of safe approaches to the carotid artery. (author)

  14. CT and MR imaging of the kidney and adrenal glands: CT of the kidney

    International Nuclear Information System (INIS)

    Levine, E.

    1987-01-01

    Because of its high diagnostic yield, safety, and cost-effectiveness, CT has become a major imaging technique for evaluating the kidney. CT is highly accurate for determining the nature and extent of renal masses, and this has become the main indication for renal CT. However, CT is also valuable in assessing patients with renal cystic disease, trauma, inflammatory disease, infarction, hemorrhage and hydronephrosis of unknown cause. This presentation reviews the normal CT anatomy of the kidneys and the usefulness of CT in the diagnosis of all these conditions. Examination techniques are discussed with particular emphasis on avoiding diagnostic pitfalls and tailoring the examination to the nature of the clinical problem. CT findings in various renal disorders are compared with those of other imaging techniques, particularly US and angiography, and the place of CT in the diagnostic approach to these disorders is considered

  15. Pre-operative CT angiography and three-dimensional image post processing for deep inferior epigastric perforator flap breast reconstructive surgery.

    Science.gov (United States)

    Lam, D L; Mitsumori, L M; Neligan, P C; Warren, B H; Shuman, W P; Dubinsky, T J

    2012-12-01

    Autologous breast reconstructive surgery with deep inferior epigastric artery (DIEA) perforator flaps has become the mainstay for breast reconstructive surgery. CT angiography and three-dimensional image post processing can depict the number, size, course and location of the DIEA perforating arteries for the pre-operative selection of the best artery to use for the tissue flap. Knowledge of the location and selection of the optimal perforating artery shortens operative times and decreases patient morbidity.

  16. Non-invasive prediction of hemodynamically significant coronary artery stenoses by contrast density difference in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hell, Michaela M., E-mail: michaela.hell@uk-erlangen.de [Department of Cardiology, University of Erlangen (Germany); Dey, Damini [Department of Biomedical Sciences, Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Taper Building, Room A238, 8700 Beverly Boulevard, Los Angeles, CA 90048 (United States); Marwan, Mohamed; Achenbach, Stephan; Schmid, Jasmin; Schuhbaeck, Annika [Department of Cardiology, University of Erlangen (Germany)

    2015-08-15

    Highlights: • Overestimation of coronary lesions by coronary computed tomography angiography and subsequent unnecessary invasive coronary angiography and revascularization is a concern. • Differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve, were assessed. • At a threshold of ≥24%, contrast density difference predicted hemodynamically significant lesions with a specificity of 75%, sensitivity of 33%, PPV of 35% and NPV of 73%. • The determination of contrast density difference required less time than transluminal attenuation gradient measurement. - Abstract: Objectives: Coronary computed tomography angiography (CTA) allows the detection of obstructive coronary artery disease. However, its ability to predict the hemodynamic significance of stenoses is limited. We assessed differences in plaque characteristics and contrast density difference between hemodynamically significant and non-significant stenoses, as defined by invasive fractional flow reserve (FFR). Methods: Lesion characteristics of 59 consecutive patients (72 lesions) in whom invasive FFR was performed in at least one coronary artery with moderate to high-grade stenoses in coronary CTA were evaluated by two experienced readers. Coronary CTA data sets were acquired on a second-generation dual-source CT scanner using retrospectively ECG-gated spiral acquisition or prospectively ECG-triggered axial acquisition mode. Plaque volume and composition (non-calcified, calcified), remodeling index as well as contrast density difference (defined as the percentage decline in luminal CT attenuation/cross-sectional area over the lesion) were assessed using a semi-automatic software tool (Autoplaq). Additionally, the transluminal attenuation gradient (defined as the linear regression coefficient between intraluminal CT attenuation and length from the ostium) was determined

  17. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  18. Real-time fusion of coronary CT angiography with X-ray fluoroscopy during chronic total occlusion PCI

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshhajra, Brian B.; Takx, Richard A.P. [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Department of Radiology and Division of Cardiology, Boston, MA (United States); Stone, Luke L.; Yeh, Robert W.; Jaffer, Farouc A. [Harvard Medical School, Cardiac Cathetrization Laboratory, Cardiology Division, Massachusetts General Hospital, Boston, MA (United States); Girard, Erin E. [Siemens Healthcare, Princeton, NJ (United States); Brilakis, Emmanouil S. [Cardiology Division, Dallas VA Medical Center and UT Southwestern Medical Center, Dallas, TX (United States); Lombardi, William L. [University of Washington, Cardiology Division, Seattle, WA (United States)

    2017-06-15

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with X-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. (orig.)

  19. Vascular involvement in pancreatic carcinoma. Pre-operative assessment by multislice CT angiography

    International Nuclear Information System (INIS)

    Ling Huawei; Guan Yongjing; Ding Bei; Lin Xiaozhu; Zhang Huan; Chen Kemin

    2002-01-01

    Objective: To study the value of multislice CT angiography (MSCTA) in the pre-operative assessment of vascular involvement in pancreatic carcinoma. Methods: 33 cases with pathologically proven pancreatic carcinoma underwent MSCTA prior to surgical intervention. The MSCTA findings in each of the 33 patients were evaluated prospectively by four radiologists. Vascular involvement of pancreatic carcinoma was validated at the time of surgery, which was a reference standard for comparison. Correlation was made between MSCTA findings and surgical results. Results: 11 out of 33 cases with pancreatic carcinoma were considered to be resectable by MSCTA with a positive predictive value of 82% in comparison with surgical findings. MSCTA also had high correlation with surgical results in assessing the non-resectability of pancreatic carcinoma (positive predictive value =95%). Conclusion: MSCTA could delineate the vascular involvement of pancreatic carcinoma with high accuracy and provided valuable information in the preoperative assessment of pancreatic carcinoma

  20. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    International Nuclear Information System (INIS)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven; Mavili, Ertugrul; Durak, Ahmet Candan; Menkue, Ahmet

    2011-01-01

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  1. Intravenous coronary angiography by electron beam computed tomography : a clinical evaluation

    NARCIS (Netherlands)

    Rensing, B J; Bongaerts, A; van Geuns, R J; van Ooijen, P; Oudkerk, M; de Feyter, P J

    1998-01-01

    BACKGROUND: -Noninvasive detection of coronary stenoses with electron beam CT (EBCT) after intravenous injection of contrast medium has recently emerged. We sought to determine the diagnostic accuracy of EBCT angiography in the clinical setting using conventional coronary angiography as the "gold

  2. Watershed infarctions - a special type of infarction in cases with carotid artery stenosis or occlusion verified by CT and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Wodarz, R; Ratzka, M; Grosse, D

    1981-02-01

    Watershed infarctions appear in the axial CT-sections mostly as stained or striated hypodense areas in the white matter of the parietal and seldom temporal region, without or with extension into the supply area of the adjacent cerebral arteries. We observed these changes in approximately 40% of our series with carotid artery stenosis or occlusion. These findings may be very subtle, and in such cases angiography should be performed.

  3. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  4. The emerging age of endovascular treatment of acute ischaemic stroke and the role of CT angiography in patient work-up: a guide for the radiologist

    International Nuclear Information System (INIS)

    Loughborough, W.; Mahady, K.; Bradley, M.D.; Renowden, S.A.; Mortimer, A.M.

    2016-01-01

    Recent trial evidence suggests that for patients suffering large-vessel occlusive stroke, endovascular therapy based on the stent-retriever technique is associated with superior clinical outcomes when compared to intravenous thrombolysis alone. The challenge now is how this service is to be delivered. This may involve both centralisation of services around large cities and development of robust networks to receive patients from district general hospitals situated further afield. Both diagnostic and interventional neuroradiology will need to expand. Furthermore, we suggest that it would be advantageous for radiology departments in those hospitals receiving hyperacute stroke patients to perform computed tomography (CT) angiography in addition to non-contrast CT, which also has implications for service delivery in these units. This could swiftly aid identification of patients who might benefit from thrombectomy and improve decision-making through demonstration of occlusive thrombus and of collateral status.

  5. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Morsbach, Fabian; Gordic, Sonja; Husarik, Daniela; Frauenfelder, Thomas; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Desbiolles, Lotus; Leschka, Sebastian [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Kantonsspital St. Gallen, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Schmidt, Bernhard; Allmendinger, Thomas [Siemens AG, Healthcare Sector, Forchheim (Germany); Wildermuth, Simon [Kantonsspital St. Gallen, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland)

    2014-08-15

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. (orig.)

  6. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience

    International Nuclear Information System (INIS)

    Morsbach, Fabian; Gordic, Sonja; Husarik, Daniela; Frauenfelder, Thomas; Alkadhi, Hatem; Desbiolles, Lotus; Leschka, Sebastian; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon

    2014-01-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. (orig.)

  7. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Boris, E-mail: boris.schell@googlemail.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Heidenreich, Ralf, E-mail: ralf.heidenreich@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Heidenreich, Monika, E-mail: info@roentgen-consult.de [Röntgen-Consult Company, Schulhausstrasse 37, 79199 Kirchzarten (Germany); Eichler, Katrin, E-mail: k.eichler@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Thalhammer, Axel, E-mail: axel.thalhammer@kgu.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Naeem, Naguib Nagy Naguib, E-mail: nagynnn@yahoo.com [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas Josef, E-mail: T.Vogl@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Zangos, Stefan, E-mail: Zangos@em.uni-frankfurt.de [Goethe University Hospital, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany)

    2012-12-15

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  8. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications.

    Science.gov (United States)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-12-01

    To evaluate the radiation exposure for operating personnel associated with rotational flat-panel angiography and C-arm cone beam CT. Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8s/rotation, 20s/rotation and 5s/2 rotations), and 47 cm×18 cm (16s/2 rotations) and standard 2D angiography (10s, FOV 24 cm×18 cm). Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8s/rotation: 28.0 μSv, 20s/rotation: 79.3 μSv, 5s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20s/rotation). Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  9. Radiation exposure to operating staff during rotational flat-panel angiography and C-arm cone beam computed tomography (CT) applications

    International Nuclear Information System (INIS)

    Schulz, Boris; Heidenreich, Ralf; Heidenreich, Monika; Eichler, Katrin; Thalhammer, Axel; Naeem, Naguib Nagy Naguib; Vogl, Thomas Josef; Zangos, Stefan

    2012-01-01

    Purpose: To evaluate the radiation exposure for operating personel associated with rotational flat-panel angiography and C-arm cone beam CT. Materials and methods: Using a dedicated angiography-suite, 2D and 3D examinations of the liver were performed on a phantom to generate scattered radiation. Exposure was measured with a dosimeter at predefined heights (eye, thyroid, breast, gonads and knee) at the physician's location. Analysis included 3D procedures with a field of view (FOV) of 24 cm × 18 cm (8 s/rotation, 20 s/rotation and 5 s/2 rotations), and 47 cm × 18 cm (16 s/2 rotations) and standard 2D angiography (10 s, FOV 24 cm × 18 cm). Results: Measurements showed the highest radiation dose at the eye and thyroid level. In comparison to 2D-DSA (3.9 μSv eye-exposure), the 3D procedures caused an increased radiation exposure both in standard FOV (8 s/rotation: 28.0 μSv, 20 s/rotation: 79.3 μSv, 5 s/2 rotations: 32.5 μSv) and large FOV (37.6 μSv). Proportional distributions were measured for the residual heights. With the use of lead glass, irradiation of the eye lens was reduced to 0.2 μSv (2D DSA) and 10.6 μSv (3D technique with 20 s/rotation). Conclusion: Rotational flat-panel angiography and C-arm cone beam applications significantly increase radiation exposure to the attending operator in comparison to 2D angiography. Our study indicates that the physician should wear protective devices and leave the examination room when performing 3D examinations.

  10. Juvenile nasopharyngeal angiofibroma - study of the tumor extension and vascularization through computerized tomography (CT) scan and angiography and the patient's age

    International Nuclear Information System (INIS)

    Sennes, Luiz Ubirajara

    1997-01-01

    The juvenile nasopharyngeal angiofibroma is a rare benign tumor that affects male adolescents. It is a fibro-vascular tumor with an exuberant intra tumor blood flow and irrigated by several arteries. It originates from the lateral and posterior region of the nasal cavity and, due to its characteristic multidirectional growth, widely affects the paranasal sinuses and skull base, sometimes invading the cranial fossa or the cheek. The determinant factors of its growth and vascularisation are unknown. Attempting to clarify them, 33 patients from the University of Sao Paulo Medicine were studied from 1983 to 1995, with complete history and radiological documentation (CT scan and angiography), as well as with histological confirmation of the diagnosis. In order to take only tumors with natural evolution, patients with recidivant tumor and those already submitted to any previous treatment were excluded. The parameters evaluate were: patient age and tumor extension (by classification, degree of invasion and number of compromised sites in CT scan) and vascularisation (by number and degree of participation of bilateral arteries in angiography). The se data were tabled and correlated one with each other. (author)

  11. Usefulness of computed tomography (CT) in the diagnosis of portosystemic collaterals in liver cirrhosis

    International Nuclear Information System (INIS)

    Tsukune, Yoshihiko

    1984-01-01

    This study assesses the usefulness of computed tomography (CT) in the diagnosis of portosystemic collaterals in liver cirrhosis. Seventy-eight patients with liver cirrhosis underwent both CT and angiography. Comparison was made between CT and angiography on eleven types of collaterals, and many of them were demonstrated on CT scans better than angio. Especially, esophageal varices, paraesophageal varices, umbilical pathway and caput medusa were diagnostic on CT scans. Gastrorenal collaterals, splenorenal collaterals, retroperitoneal pathway are also well demonstrated. Dilatation of azygos systems and small veins in the liver surface are only observed on CT scans. However, coronary varices and short gastric varices are well diagnostic in angiography. But considering all types of collaterals, it was stressed that angiography can be eliminated by CT in evaluation of collaterals in liver cirrhosis. (author)

  12. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Higashihara, Hiroki; Osuga, Keigo; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Hori, Masatoshi; Kim, Tonsok; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2012-04-15

    This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. (orig.)

  13. The need for repeat angiography in subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Urbach, H.; Solymosi, L.; Zentner, J.

    1998-01-01

    This study was designed to assess the necessity for a second angiogram study in patients in whom initial angiography after primary subarachnoid haemorrhage (SAH) was negative. During a 12-year period, 122 of 694 patients (17.5 %) had negative initial angiograms. CT, available for 98 patients, showed a preponderance of subarachnoid blood in the perimesencephalic cisterns in 50 of 73 patients (68.5 %) in whom blood was visible on CT. Angiography, repeated in 67 patients, revealed an aneurysm in 4 (6 %): 2 had an aneurysm of the anterior communicating artery, 1 of the posterior inferior cerebellar artery, and 1 of the P2 segment of the posterior cerebral artery. CT showed subarachnoid blood in the interpeduncular and ambient cisterns in this last case, and a preponderance of subarachnoid blood outside the perimesencephalic cisterns in the remaining 3 patients. (orig.)

  14. The influence factors in image quality of multi-slice spiral CT coronary angiography (MSCTA)

    International Nuclear Information System (INIS)

    Zeng Huiliang; Zhu Xinjin; Liang Jianhao; Zhong Yingze; Chen Xueguang; Ou Weiqian; Wen Haomao; Li Peiwen

    2007-01-01

    Objective: To evaluate the influence of heart rate on image quality of multi-slice spiral CT coronary angiography(MSCTA) and the optimization of image reconstruction windows. Methods: Retrospectively ECG-gated MSCT coronary angiography were performed in 67 cases. The cases were divided into four groups by heart rate, groupl with heart rate less than 60 beats per minute(bpm), group 2 with heart rate 61-70 bpm, group 3 with heart rate 71-80 bpm and group 4 with heart rate over 81 bpm. The impact of heart rate on image quality of MSCTA and the optimization of image reconstruction windows were evaluated. Results: 4 coronary (RCA,LM,LAD,LCX) segments were analyzed in each patients with regard to image quality. 86.7%(112/128) of the coronary segments were sufficient for analysis in patients with heart rate less than 60 bpm,62.5%(55/88) with 61-70 bpm,40%(8/20) with 71-80 bpm and 12.5%(2/16) with heart rate over 81 bpm, respectively. There were statistically significances between every coronary segments of group 1 and 2, group 3 and 4 (P<0.05). All coronary segments of group 1 were optimally visualized on the image reconstructed at 75% image reconstruction window of' cardiac cycle; 89.5% cases at 75% in group 2; for group 3.55% of coronary artery were best presented at 75% image reconstruction window, 45% of coronary artery at 45%; All coronary segments of group 4 were optimally visualized on the image reconstructed at 45% image reconstruction window. Conclusion: Image quality of MSCT coronary angiography is highly dependent on heart rate. Coronary artery is usually best shown at 75% image reconstruction window of cardiac cycle for those with heart rate less than 70 bpm. 30%-90% image reconstruction should be performed when heart rate is over 71 bpm. (authors)

  15. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  16. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    Energy Technology Data Exchange (ETDEWEB)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Patrie, James T.; Xin, Wenjun [University of Virginia, Department of Public Health Sciences, Charlottesville, VA (United States); Wintermark, Max [University of Virginia, Department of Radiology and Medical Imaging, Division of Neuroradiology, PO Box 800170, Charlottesville, VA (United States); Centre Hospitalier Universitaire Vaudois, Department of Radiology, Lausanne (Switzerland)

    2014-03-15

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI{sub vol}), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI{sub vol} and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  17. Adaptive statistical iterative reconstruction reduces patient radiation dose in neuroradiology CT studies

    International Nuclear Information System (INIS)

    Komlosi, Peter; Zhang, Yanrong; Leiva-Salinas, Carlos; Ornan, David; Grady, Deborah; Patrie, James T.; Xin, Wenjun; Wintermark, Max

    2014-01-01

    Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDI vol ), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDI vol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality. (orig.)

  18. Variations in Branching Pattern of Renal Artery in Kidney Donors Using CT Angiography.

    Science.gov (United States)

    Munnusamy, Kumaresan; Kasirajan, Sankaran Ponnusamy; Gurusamy, Karthikeyan; Raghunath, Gunapriya; Bolshetty, Shilpakala Leshappa; Chakrabarti, Sudakshina; Annadurai, Priyadarshini; Miyajan, Zareena Begum

    2016-03-01

    Each kidney is supplied by a single renal artery originating from abdominal aorta. Since there are lots of renal surgeries happening now-a-days, it becomes mandatory for the surgeons to understand the abnormality and variations in the renal vasculature. To study the variations in the branching pattern of renal artery for the presence of early division and accessory renal artery in Indian kidney donors using CT angiography. The CT angiogram images of 100 normal individuals willing for kidney donation were analysed for early divisions and occurrence of accessory renal artery. A 51% of kidney donors showed variation in the renal artery. Out of 51% variations 38 individuals had accessory renal artery and 13 individuals had early division of renal artery. The distribution of accessory renal artery was equal on both sides (13% on right and left) and 12% of individuals had accessory renal artery on both sides. Out of 13% earlier divisions, 5% was on right side, 7% was on left side and 1% was on both sides. This study concludes that 51% of kidney donors had renal artery variations. Hence, awareness of variations by evaluating the donors is a must before renal transplantation, urological procedures and angiographic interventions.

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  20. Optimized contrast volume for dynamic CT angiography in renal transplant patients using a multiphase CT protocol

    International Nuclear Information System (INIS)

    Helck, A.; Bamberg, F.; Sommer, W.H.; Wessely, M.; Becker, C.; Clevert, D.A.; Notohamiprodjo, M.; Reiser, M.; Nikolaou, K.

    2011-01-01

    Objectives: To study the feasibility of an optimized multiphase renal-CT-angiography (MP-CTA) protocol in patients with history of renal transplantation compared with Doppler-ultrasound (DUS). Methods: 36 Patients underwent both DUS and time-resolved, MP-CTA (12 phases), with a mean contrast-volume of 34.4 ± 5.1 ml. Quality of MP-CTA was assessed quantitatively (vascular attenuation) and qualitatively (grades 1–4, 1 = best). For the assessment of clinical value of MP-CTA, cases were grouped into normal, macrovascular (arterial/venous) and microvascular complications (parenchymal perfusion defect). DUS served as the standard of reference. Results: Using the best of 12 phases in each patient, optimal attenuation was 353 ± 111 HU, 337 ± 98 HU and 164 ± 51 HU in the iliac arteries, renal arteries, and renal veins, respectively. Mean image quality was 1.1 ± 0.3 (n = 36) and 2.1 ± 0.6 (n = 30) for the transplant renal arteries and veins, respectively. Six renal veins were non-diagnostic in MP-CTA. In 36 patients, MP-CTA showed 13 vascular complications and 10 parenchymal perfusion defects. DUS was not assessable in eight patients. Overall, MP-CTA showed 15 cases with pathology (42%) not identifiable with DUS. The mean effective radiation dose of the MP-CTA protocol was 13.5 ± 5.2 mSv. Conclusion: MP-CTA can be sufficiently performed with reduced contrast volume at reasonable radiation dose in renal transplant patients, providing substantially higher diagnostic yield than DUS.

  1. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  2. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    International Nuclear Information System (INIS)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio; Sanfilippo, Roberto; Montisci, Roberto; Pascalis, Luigi

    2008-01-01

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value ± standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with ≥1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  3. Carotid artery wall thickness and ischemic symptoms: evaluation using multi-detector-row CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Caddeo, Giancarlo; Mallarini, Giorgio [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Radiology, Cagliari (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria Polo di Monserrato, Department of Vascular Surgery, Cagliari (Italy); Pascalis, Luigi [Azienda Ospedaliero Universitaria Polo di Cagliari, Division of II Internal Medicine, Cagliari (Italy)

    2008-09-15

    The purpose of this study was to determine if carotid artery wall thickness (CAWT) studied by using multi-detector-row CT angiography (MDCTA) can be considered an effective parameter predictive of increased risk of stroke. A total of 217 patients were retrospectively studied by using MDCTA. In all patients CAWT was measured with an internal digital caliper. Continuous data were described as the mean value {+-} standard deviation (SD), and they were compared with Student's t-test. Scatter plots to determine interobserver agreement were performed, and correlation coefficient was calculated with Pearson statistics. A P value <0.05 was considered to mean statistical significance. Measurements of the distal common CAWT ranged from 0.5 to 1.6 mm. In the patient group without stroke, average CAWT was 0.82 mm (0.22 SD), whereas in patient group with stroke it was 1.096 mm (0.21 SD). CAWT in patients without stroke showed statistical difference (P<0.0001) when compared to patients with stroke. By using a threshold of 1 mm, an important statistical association between thick CAWT and stroke was found (P<0.0001). In fact, patients with {>=}1 mm CAWT had stroke with an odds ratio of 8.16 when compared with patients with <1 mm CAWT. Resulting data suggested that an increased CAWT is an indicator for risk of stroke. This parameter should be considered in addition to other well-known risk factors such as diabetes, hypertension, smoking, and dyslipidemia. (orig.)

  4. Multidetector CT angiography influences the choice of treatment for blunt carotid artery injury.

    Science.gov (United States)

    Beliaev, Andrei M; Civil, Ian

    2014-08-06

    A 43-year-old woman presented with a 2 h history of left neck pain after striking her neck against a marble bench while playing with her son. The patient was screened for blunt cerebrovascular injury (BCVI) and a left carotid bruit was identified. Subsequently, she underwent multidetector CT angiography (MCTA) of the aortic arch and neck vessels, which demonstrated a flow-limiting dissection of the left common carotid artery (CCA). The patient was started on heparin infusion and underwent an emergency operation. At surgery, a circumferential intimal dissection was excised and the arteriotomy defect closed with an autologous venous patch. This case emphasises the importance of adequately examining patients with direct injury to the neck, screening relevant patients for BCVI and investigating them with MCTA that influences the choice of a treatment option. 2014 BMJ Publishing Group Ltd.

  5. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  6. Usefulness of CT in diagnosing and staging of kidney cancer

    International Nuclear Information System (INIS)

    Batycka-Ugorska, I.

    1993-01-01

    Article presents 170 patients with suspected kidney cancer and applicability of CT in the diagnosis. According to author CT imaging is better than others (ultrasonography, urography) in assessment of the tumor development and detection of metastases to lymphatic nodes of abdomen and other organs. The method is compared with angiography in diagnosis of metastases of kidney cancer to veins

  7. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  8. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  9. Case report: Isolated unilateral pulmonary vein atresia diagnosed on 128-slice multidetector CT

    Directory of Open Access Journals (Sweden)

    Rashmi Dixit

    2011-01-01

    Full Text Available Unilateral pulmonary venous atresia is an uncommon entity that is generally believed to be congenital. Most patients present in infancy or childhood with recurrent chest infections or hemoptysis. Pulmonary angiography is usually used for definitive diagnosis. However, the current multislice CT scanners may obviate the need for pulmonary angiography. We report two cases diagnosed using 128-slice CT angiography. On the CT angiography images both these cases demonstrated absent pulmonary veins on the affected side, with a small pulmonary artery and prominent bronchial or other systemic arterial supply.

  10. Differentiation of chronic total occlusion and subtotal occlusion of the femoropopliteal artery-role of retrograde flow sign and collateral circulation on CT angiography images.

    Science.gov (United States)

    Zhang, Shujun; Su, Yanfei; Chen, Haisong

    2017-08-01

    To study the value of a retrograde flow sign and the collateral circulation on CT angiography (CTA) for the differential diagnosis of chronic total occlusion from subtotal occlusion of the femoropopliteal artery (FPA). 50 patients with obstruction of the FPA underwent CTA and digital subtraction angiography examinations of the lower limbs. The frequency of a retrograde flow sign and collateral circulation on CTA in chronic total and subtotal occlusion was noted and analyzed, with the results of digital subtraction angiography as a standard to judge total or subtotal occlusion. The decreasing CT value from the distal to proximal direction on CTA suggests the existence of retrograde flow. There were significant differences in the occurrence rates of a retrograde flow sign on CTA in the chronic total and subtotal obstruction groups (X 2 = 13.1, p collateral circulation sign (X 2 = 13.5, p collateral circulation sign to diagnose chronic total obstruction of the FPA had a sensitivity of 92.3% and specificity of 89.8%. The retrograde flow sign combined with a collateral circulation sign is of great clinical value for differentiation of chronic total stenosis from severe stenosis (subtotal occlusion) of the FPA. Advances in knowledge: A retrograde flow sign combined with a collateral circulation sign is of great clinical value to differentiate between chronic total stenosis and severe stenosis (subtotal occlusion) of the FPA.

  11. The Role of Multi-slice Spiral CT Angiography in Patient Management After Endovascular Therapy

    International Nuclear Information System (INIS)

    Peloschek, P.; Sailer, J.; Loewe, C.; Schillinger, M.; Lammer, J.

    2006-01-01

    Objectives. To bring out the role of multi-slice spiral CT angiography (MS-CTA) in patient management after endovascular therapy of subclavian artery stenosis. Methods. Twenty-one consecutive patients with clinically suspected restenosis after endovascular treatment of subclavian artery stenosis or occlusion were included in the study. Eleven patients had been treated with percutaneous transluminal angioplasty (PTA) alone and 10 with PTA and stenting. The mean follow-up period after PTA or stenting was 57 (±27 SD) months. CTA was performed using a bolus-triggered high-resolution protocol with biphasic intravenous contrast medium injection. Axial images and curved planar reformations (CPRs) were rated by three readers with regard to patency of supra-aortic vessels. Imaging findings were correlated with a standardized clinical assessment. Results. All examinations were of diagnostic quality. Of 21 referred patients, 7 had significant reobstruction of the treated subclavian artery. Six of the 7 patients with significant restenosis on CTA were treated conservatively (antiplatelet agents), despite 2 of them being symptomatic on the standardized clinical assessment, which showed a sensitivity and specificity of 86% in predicting stenosis. One patient was treated with PTA and stent deployment because of strong subjective suffering. Conclusion. MS-CTA is useful for exclusion or quantification of clinically suspected restenosis in carefully selected patients after endovascular therapy where ultrasound is inconclusive and/or contrast-enhanced magnetic resonance angiography is contraindicated

  12. Contrast enhanced CT of spinal cord angioma

    International Nuclear Information System (INIS)

    Nakamura, Takahiko; Ebitani, Tsutomu; Honma, Takao; Sofue, Muroto; Nakamura, Shigeru

    1982-01-01

    Contrast enhanced CT on 6 patients with spinal cord angioma showed enhancement in 2 of them. The conditions to produce contrast enhancement were the window width of 100 - 200, and the window level of 0 - 50. In spinal cord angioma, contrast enhanced CT is presently only an adjunct to angiography and myelography. Nevertheless, contrast enhanced CT is useful in the screening test for spinal cord angioma, in the patients who are nonindicated to angiography, and in the postoperative follow-up. (Ueda, J.)

  13. Fusion of CT coronary angiography and whole-heart dynamic 3D cardiac MR perfusion: building a framework for comprehensive cardiac imaging.

    Science.gov (United States)

    von Spiczak, Jochen; Manka, Robert; Gotschy, Alexander; Oebel, Sabrina; Kozerke, Sebastian; Hamada, Sandra; Alkadhi, Hatem

    2018-04-01

    The purpose of this work was to develop a framework for 3D fusion of CT coronary angiography (CTCA) and whole-heart dynamic 3D cardiac magnetic resonance perfusion (3D-CMR-Perf) image data-correlating coronary artery stenoses to stress-induced myocardial perfusion deficits for the assessment of coronary artery disease (CAD). Twenty-three patients who underwent CTCA and 3D-CMR-Perf for various indications were included retrospectively. For CTCA, image quality and coronary diameter stenoses > 50% were documented. For 3D-CMR-Perf, image quality and stress-induced perfusion deficits were noted. A software framework was developed to allow for 3D image fusion of both datasets. Computation steps included: (1) fully automated segmentation of coronary arteries and heart contours from CT; (2) manual segmentation of the left ventricle in 3D-CMR-Perf images; (3) semi-automatic co-registration of CT/CMR datasets; (4) projection of the 3D-CMR-Perf values on the CT left ventricle. 3D fusion analysis was compared to separate inspection of CTCA and 3D-CMR-Perf data. CT and CMR scans resulted in an image quality being rated as good to excellent (mean scores 3.5 ± 0.5 and 3.7 ± 0.4, respectively, scale 1-4). 3D-fusion was feasible in all 23 patients, and perfusion deficits could be correlated to culprit coronary lesions in all but one case (22/23 = 96%). Compared to separate analysis of CT and CMR data, coronary supply territories of 3D-CMR-Perf perfusion deficits were refined in two cases (2/23 = 9%), and the relevance of stenoses in CTCA was re-judged in four cases (4/23 = 17%). In conclusion, 3D fusion of CTCA/3D-CMR-Perf facilitates anatomic correlation of coronary lesions and stress-induced myocardial perfusion deficits thereby helping to refine diagnostic assessment of CAD.

  14. SU-E-I-31: Differences Observed in Radiation Doses Across 2 Similar CT Scanners From Adult Brain-Neck CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, K [Graduate School of Medicine, Nagoya University, Nagoya, JP (Japan); UCLA School of Medicine, Los Angeles, CA (United States); McMillan, K; Bostani, M; Cagnon, C; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2015-06-15

    Purpose: The aim of this study is to evaluate the difference in radiation doses from adult Brain-Neck CT angiography (CTA) between two CT scanners. Methods: We collected CT dose index data (CTDIvol, DLP) from adult Brain-Neck CTA performed with two CT scanners (Sensation 64 (S64) and Definition AS (AS), Siemens Healthcare) performed at two of our facilities from Jan 1st to Dec 31th, 2014. X-ray dose management software (Radmetrics, Bayer Healthcare) was used to mine these data. All exams were performed with Tube Current Modulation (Care Dose 4D), tube voltage of 120 kVp, quality reference mAs of 300, beam collimation of 64*0.6 mm. The rotation time was set to 0.5 sec for S64 and 1.0 sec for AS. We also scanned an anthropomorphic skull and chest phantom under routine Brain-Neck CTA protocol with the two scanners and extracted the tube current values from the raw projection data. Results: The mean CTDIvol and DLP in Brain-Neck CTA was 72 mGy and 2554 mGy*cm for AS, which was substantially larger than the mean values of 46 mGy and 1699 mGy*cm for S64. The maximum tube current was 583 mA for most cases on the S64 while the maximum was 666 mA for AS even though the rotation time set for AS was 1.0 sec. Measurements obtained with the anthropomorphic phantom showed that the tube current reached 583 mA at the shoulder region for S64 while it reached to 666 mA for AS. Conclusion: The results of this study showed that substantially different CT doses can Result from Brain-Neck CTA protocols even when similar scanners and similar settings are used. Though both scanners have a similar maximum mA rating, differences in mA were observed through the shoulders, resulting in substantially different CTDIvol values.

  15. Comparative effectiveness of coronary CT angiography vs stress cardiac imaging in patients following hospital admission for chest pain work-up: The Prospective First Evaluation in Chest Pain (PERFECT) Trial.

    Science.gov (United States)

    Uretsky, Seth; Argulian, Edgar; Supariwala, Azhar; Agarwal, Shiv K; El-Hayek, Georges; Chavez, Patricia; Awan, Hira; Jagarlamudi, Ashadevi; Puppala, Siva P; Cohen, Randy; Rozanski, Alan

    2017-08-01

    Because the frequency of cardiac event rates is low among chest pain patients following either performance of coronary CT angiography (CCTA) or stress testing, there is a need to better assess how these tests influence the central management decisions that follow from cardiac testing. The present study was performed to assess the relative impact of CCTA vs stress testing on medical therapies and downstream resource utilization among patients admitted for the work-up of chest pain. The admitted patients were randomized in a 1:1 ratio to either cardiac imaging stress test or CCTA. Primary outcomes were time to discharge, change in medication usage, and frequency of downstream testing, cardiac interventions, and cardiovascular re-hospitalizations. We randomized 411 patients, 205 to stress testing, and 206 to CCTA. There were no differences in time to discharge or initiation of new cardiac medications at discharge. At 1 year follow-up, there was no difference in the number of patients who underwent cardiovascular downstream tests in the CCTA vs stress test patients (21% vs 15%, P = .1) or cardiovascular hospitalizations (14% vs 16%, P = .5). However, there was a higher frequency of invasive angiography in the CCTA group (11% vs 2%, P = .001) and percutaneous coronary interventions (6% vs 0%, P work-up to either CCTA or to stress testing resulted in similar discharge times, change in medical therapies at discharge, frequency of downstream noninvasive testing, and repeat hospitalizations. However, a higher frequency of invasive coronary angiography and revascularization procedures were performed in the CCTA arm. (ClinicalTrials.gov number, NCT01604655.).

  16. Magnetic resonance angiography of cerebral developmental venous anomalies: its role in differential diagnosis

    International Nuclear Information System (INIS)

    Ostertun, B.; Solymosi, L.

    1993-01-01

    CT, MRI and contrast angiography of 20 patients with 21 developmental venous anomalies (DVAs), so-called venous angiomas, were compared with magnetic resonance angiography employing a two-dimensional time-of-flight technique (2D-MRA). MRA was diagnostic in 17 DVAs, when both the primary 2D slices and the maximum-intensity-protection images were read. Contrast angiography still provides the best visualization of both DVA components: dilated medullary veins and transcerebral draining vein; however, it is an invasive procedure and delivers no information about brain parenchyma. We regard MRI as necessary in cases with a suspected DVA because of the high rate of association with cavernomas: 33% in this study. Acute neurological symptoms were caused by haemorrhage from an associated cavernoma and not from the DVA in 4 such cases. Thus MRA combined with MRI obviates angiography in most cases and offers a noninvasive diagnostic strategy adequate for DVAs. (orig.)

  17. The need for repeat angiography in subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Urbach, H; Solymosi, L [Department of Neuroradiology, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Zentner, J [Department of Neurosurgery, University of Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    1998-01-01

    This study was designed to assess the necessity for a second angiogram study in patients in whom initial angiography after primary subarachnoid haemorrhage (SAH) was negative. During a 12-year period, 122 of 694 patients (17.5 %) had negative initial angiograms. CT, available for 98 patients, showed a preponderance of subarachnoid blood in the perimesencephalic cisterns in 50 of 73 patients (68.5 %) in whom blood was visible on CT. Angiography, repeated in 67 patients, revealed an aneurysm in 4 (6 %): 2 had an aneurysm of the anterior communicating artery, 1 of the posterior inferior cerebellar artery, and 1 of the P2 segment of the posterior cerebral artery. CT showed subarachnoid blood in the interpeduncular and ambient cisterns in this last case, and a preponderance of subarachnoid blood outside the perimesencephalic cisterns in the remaining 3 patients. (orig.) With 2 figs., 1 tab., 32 refs.

  18. DNA double-strand breaks as potential indicators for the biological effects of ionising radiation exposure from cardiac CT and conventional coronary angiography: a randomised, controlled study

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik; Zimmermann, Elke; Rief, Matthias; Greupner, Johannes; Hamm, Bernd [Charite Medical School, Department of Radiology, Berlin (Germany); Laule, Michael; Knebel, Fabian [Charite Medical School, Department of Cardiology, Berlin (Germany); Dewey, Marc [Charite Medical School, Department of Radiology, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2012-08-15

    To prospectively compare induced DNA double-strand breaks by cardiac computed tomography (CT) and conventional coronary angiography (CCA). 56 patients with suspected coronary artery disease were randomised to undergo either CCA or cardiac CT. DNA double-strand breaks were assessed in fluorescence microscopy of blood lymphocytes as indicators of the biological effects of radiation exposure. Radiation doses were estimated using dose-length product (DLP) and dose-area product (DAP) with conversion factors for CT and CCA, respectively. On average there were 0.12 {+-} 0.06 induced double-strand breaks per lymphocyte for CT and 0.29 {+-} 0.18 for diagnostic CCA (P < 0.001). This relative biological effect of ionising radiation from CCA was 1.9 times higher (P < 0.001) than the effective dose estimated by conversion factors would have suggested. The correlation between the biological effects and the estimated radiation doses was excellent for CT (r = 0.951, P < 0.001) and moderate to good for CCA (r = 0.862, P < 0.001). One day after radiation, a complete repair of double-strand breaks to background levels was found in both groups. Conversion factors may underestimate the relative biological effects of ionising radiation from CCA. DNA double-strand break assessment may provide a strategy for individualised assessments of radiation. (orig.)

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... cavities (ventricles) in patients with hydrocephalus . diseases or malformations of the skull. CT scanning is also performed ... biopsy ) from the brain. assess aneurysms or arteriovenous malformations through a technique called CT angiography. For more ...

  20. CT angiography of the renal arteries and veins: normal anatomy and variants.

    Science.gov (United States)

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  1. Blurring of the vessels of the interhemispheric fissure in multislice CT angiography: a sign of meningeal carcinomatosis

    International Nuclear Information System (INIS)

    Ertl-Wagner, Birgit B.; Hoffmann, Ralf-Thorsten; Herrmann, Karin; Reiser, Maximilian F.; Bruening, Roland; Dichgans, Martin

    2004-01-01

    Meningeal carcinomatosis remains a challenging diagnosis to make, with both cerebrospinal fluid (CSF) analysis and radiological methods having a limited sensitivity. We aimed at describing a possible diagnostic sign of multislice CT angiography (MS-CTA) in the diagnosis of meningeal carcinomatosis. Upon retrospective analysis of MSCT angiographies of the brain, a conspicuous sign of the vessels of the interhemispheric fissure was noted in five patients. Cranial MSCT angiographies were performed with a standardized protocol (120 kV, 200 mA s, collimation of 4 x 1 mm, table feed per rotation 4 mm). We injected 120 ml of nonionic contrast medium as a bolus, and data acquisition was started after a fixed delay of 35 s. In order to elucidate the finding, correlation with clinical follow-up and/or CSF findings was performed for all patients. In five patients there was a blurring, an increased number, and a pathologic configuration of the vessels of the interhemispheric fissure. All five patients with this sign had clinical signs and symptoms of meningeal carcinomatosis. Three patients had positive CSF cytology, one further patient had follow-up spinal MRI 6 weeks later demonstrating meningeal carcinomatosis. One patient declined lumbar puncture. MS-CTA has the capacity to demonstrate a pathologic configuration of the vessels of the interhemispheric fissure in patients with meningeal carcinomatosis. This sign may serve as an indicator of meningeal carcinomatosis and should raise the suspicion of this disease entity. (orig.)

  2. Change in Imaging Findings on Angiography-Assisted CT During Balloon-Occluded Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoshimatsu, Rika [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Yamagami, Takuji, E-mail: yamagami@kochi-u.ac.jp [Kochi University, Department of Radiology (Japan); Ishikawa, Masaki; Kajiwara, Kenji [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan); Aikata, Hiroshi; Chayama, Kazuaki [Hiroshima University, Department of Gastroenterology and Metabolism, Institute of Biomedical and Health Sciences (Japan); Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences (Japan)

    2016-06-15

    PurposeTo evaluate changes in imaging findings on CT during hepatic arteriography (CTHA) and CT during arterial portography (CTAP) by balloon occlusion of the treated artery and their relationship with iodized oil accumulation in the tumor during balloon-occluded transcatheter arterial chemoembolization (B-TACE).MethodsBoth B-TACE and angiography-assisted CT were performed for 27 hepatocellular carcinomas. Tumor enhancement on selective CTHA with/without balloon occlusion and iodized oil accumulation after B-TACE were evaluated. Tumorous portal perfusion defect size on CTAP was compared with/without balloon occlusion. Factors influencing discrepancies between selective CTHA with/without balloon occlusion and the degree of iodized oil accumulation were investigated.ResultsAmong 27 tumors, tumor enhancement on selective CTHA changed after balloon occlusion in 14 (decreased, 11; increased, 3). In 18 tumors, there was a discrepancy between tumor enhancement on selective CTHA with balloon occlusion and the degree of accumulated iodized oil, which was higher than the tumor enhancement grade in all 18. The tumorous portal perfusion defect on CTAP significantly decreased after balloon occlusion in 18 of 20 tumors (mean decrease from 21.9 to 19.1 mm in diameter; p = 0.0001). No significant factors influenced discrepancies between selective CTHA with/without balloon occlusion. Central area tumor location, poor tumor enhancement on selective CTHA with balloon occlusion, and no decrease in the tumorous portal perfusion defect area on CTAP after balloon occlusion significantly influenced poor iodized oil accumulation in the tumor.ConclusionsTumor enhancement on selective CTHA frequently changed after balloon occlusion, which did not correspond to accumulated iodized oil in most cases.

  3. Pulmonary CT angiography protocol adapted to the hemodynamic effects of pregnancy.

    LENUS (Irish Health Repository)

    Ridge, Carole A

    2012-02-01

    OBJECTIVE: The purpose of this study was to compare the image quality of a standard pulmonary CT angiography (CTA) protocol with a pulmonary CTA protocol optimized for use in pregnant patients with suspected pulmonary embolism (PE). MATERIALS AND METHODS: Forty-five consecutive pregnant patients with suspected PE were retrospectively included in the study: 25 patients (group A) underwent standard-protocol pulmonary CTA and 20 patients (group B) were imaged using a protocol modified for pregnancy. The modified protocol used a shallow inspiration breath-hold and a high concentration, high rate of injection, and high volume of contrast material. Objective image quality and subjective image quality were evaluated by measuring pulmonary arterial enhancement, determining whether there was transient interruption of the contrast bolus by unopacified blood from the inferior vena cava (IVC), and assessing diagnostic adequacy. RESULTS: Objective and subjective image quality were significantly better for group B-that is, for the group who underwent the CTA protocol optimized for pregnancy. Mean pulmonary arterial enhancement and the percentage of studies characterized as adequate for diagnosis were higher in group B than in group A: 321 +\\/- 148 HU (SD) versus 178 +\\/- 67 HU (p = 0.0001) and 90% versus 64% (p = 0.05), respectively. Transient interruption of contrast material by unopacified blood from the IVC was observed more frequently in group A (39%) than in group B (10%) (p = 0.05). CONCLUSION: A pulmonary CTA protocol optimized for pregnancy significantly improved image quality by increasing pulmonary arterial opacification, improving diagnostic adequacy, and decreasing transient interruption of the contrast bolus by unopacified blood from the IVC.

  4. Detection and evaluation of intracranial aneurysms with 16-row multislice CT angiography

    International Nuclear Information System (INIS)

    Tipper, G.; U-King-Im, J.M.; Price, S.J.; Trivedi, R.A.; Cross, J.J.; Higgins, N.J.; Farmer, R.; Wat, J.; Kirollos, R.; Kirkpatrick, P.J.; Antoun, N.M.; Gillard, J.H.

    2005-01-01

    AIM: The aim of this study was to assess the usefulness of 16-row multislice CT angiography (CTA) in evaluating intracranial aneurysms, by comparison with conventional digital subtraction angiography (DSA) and intraoperative findings. METHODS: A consecutive series of 57 patients, scheduled for DSA for suspected intracranial aneurysm, was prospectively recruited to have CTA. This was performed with a 16-detector row machine, detector interval 0.75 mm, 0.5 rotation/s, table speed 10 mm/rotation and reconstruction interval 0.40 mm. CTA studies were independently and randomly assessed by two neuroradiologists and a vascular neurosurgeon blinded to the DSA and surgical findings. Review of CTA was performed on workstations with an interactive 3D volume-rendered algorithm. RESULTS: DSA or intraoperative findings or both confirmed 53 aneurysms in 44 patients. For both independent readers, sensitivity and specificity per aneurysm of DSA were 96.2% and 100%, respectively. Sensitivity and specificity of CTA were also 96.2% and 100%, respectively. Mean diameter of aneurysms was 6.3 mm (range 1.9 to 28.1 mm, SD 5.2 mm). For aneurysms of less than 3 mm, CTA had a sensitivity of 91.7% for each reader. Although the neurosurgeon would have been happy to proceed to surgery on the basis of CTA alone in all cases, he judged that DSA might have provided helpful additional anatomical information in 5 patients. CONCLUSION: The diagnostic accuracy of 16-slice CTA is promising and appears equivalent to that of DSA for detection and evaluation of intracranial aneurysms. A strategy of using CTA as the primary imaging method, with DSA reserved for cases of uncertainty, appears to be practical and safe

  5. Real-time fusion of coronary CT angiography with x-ray fluoroscopy during chronic total occlusion PCI.

    Science.gov (United States)

    Ghoshhajra, Brian B; Takx, Richard A P; Stone, Luke L; Girard, Erin E; Brilakis, Emmanouil S; Lombardi, William L; Yeh, Robert W; Jaffer, Farouc A

    2017-06-01

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with x-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. • Real-time semi-automated fusion of CTA/fluoroscopy is feasible during CTO PCI. • CTA fusion data can be toggled on/off as desired during CTO PCI • Real-time CT calcium and centreline overlay could benefit antegrade dissection/reentry-based CTO PCI.

  6. Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: Image quality, radiation dose and diagnostic performance

    International Nuclear Information System (INIS)

    Sun, Hao; Hou, Xin-Yi; Xue, Hua-Dan; Li, Xiao-Guang; Jin, Zheng-Yu; Qian, Jia-Ming; Yu, Jian-Chun; Zhu, Hua-Dong

    2015-01-01

    Highlights: • GIB is a common gastrointestinal emergency with a high mortality rate. • Detection and localization of GIB source are important for imaging modality. • DSDECTA using a dual-phase scan protocol is clinically feasible. • DSDECTA with VNE and iodine map images can diagnose the active GIB source accurately. • DSDECTA can reduce radiation dose compared with conventional CT examination in GIB. - Abstract: Objectives: To evaluate the clinical feasibility of dual-source dual-energy CT angiography (DSDECTA) with virtual non-enhanced images and iodine map for active gastrointestinal bleeding (GIB). Methods: From June 2010 to December 2012, 112 consecutive patients with clinical signs of active GIB underwent DSDECTA with true non-enhanced (TNE), arterial phase with single-source mode, and portal-venous phase with dual-energy mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs). Virtual non-enhanced CT (VNE) image sets and iodine map were reformatted from ‘Liver VNC’ software. The mean CT number, noise, signal to noise ratio (SNR), image quality and radiation dose were compared between TNE and VNE image sets. Two radiologists, blinded to clinical data, interpreted images from DSDECTA with TNE (protocol 1), and DSDECTA with VNE and iodine map (protocol 2) respectively, with discordant interpretation resolved by consensus. The standards of reference included digital subtraction angiography, endoscopy, surgery, or final pathology reports. Receiver–operating characteristic (ROC) analysis was undertaken and the area under the curve (AUC) calculated for CT protocols 1 and 2, respectively. Results: There was no significant difference in mean CT numbers of all organs (including liver, pancreas, spleen, kidney, abdominal aorta, and psoas muscle) (P > 0.05). Lower noise and higher SNR were found on VNE images than TNE images (P < 0.05). Image quality of VNE was lower than that of TNE without significant difference (P > 0.05). The active GIB source was identified

  7. Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: Image quality, radiation dose and diagnostic performance

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Hao, E-mail: sunhao_robert@126.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730 (China); Hou, Xin-Yi, E-mail: hxy_pumc@126.com [Department of Radiology, Beijing Tiantan Hospital, Capital Medical University, Beijing (China); Xue, Hua-Dan, E-mail: bjdanna95@hotmail.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730 (China); Li, Xiao-Guang, E-mail: xglee88@126.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730 (China); Jin, Zheng-Yu, E-mail: zhengyu_jin@126.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Shuaifuyuan No. 1, Wangfujing Street, Dongcheng District, Beijing 100730 (China); Qian, Jia-Ming, E-mail: qjiaming57@gmail.com [Department of Gastroenterology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Yu, Jian-Chun, E-mail: yu-jch@163.com [Department of General Surgery, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China); Zhu, Hua-Dong, E-mail: huadongzhu@hotmail.com [Department of Emergency, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing (China)

    2015-05-15

    Highlights: • GIB is a common gastrointestinal emergency with a high mortality rate. • Detection and localization of GIB source are important for imaging modality. • DSDECTA using a dual-phase scan protocol is clinically feasible. • DSDECTA with VNE and iodine map images can diagnose the active GIB source accurately. • DSDECTA can reduce radiation dose compared with conventional CT examination in GIB. - Abstract: Objectives: To evaluate the clinical feasibility of dual-source dual-energy CT angiography (DSDECTA) with virtual non-enhanced images and iodine map for active gastrointestinal bleeding (GIB). Methods: From June 2010 to December 2012, 112 consecutive patients with clinical signs of active GIB underwent DSDECTA with true non-enhanced (TNE), arterial phase with single-source mode, and portal-venous phase with dual-energy mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs). Virtual non-enhanced CT (VNE) image sets and iodine map were reformatted from ‘Liver VNC’ software. The mean CT number, noise, signal to noise ratio (SNR), image quality and radiation dose were compared between TNE and VNE image sets. Two radiologists, blinded to clinical data, interpreted images from DSDECTA with TNE (protocol 1), and DSDECTA with VNE and iodine map (protocol 2) respectively, with discordant interpretation resolved by consensus. The standards of reference included digital subtraction angiography, endoscopy, surgery, or final pathology reports. Receiver–operating characteristic (ROC) analysis was undertaken and the area under the curve (AUC) calculated for CT protocols 1 and 2, respectively. Results: There was no significant difference in mean CT numbers of all organs (including liver, pancreas, spleen, kidney, abdominal aorta, and psoas muscle) (P > 0.05). Lower noise and higher SNR were found on VNE images than TNE images (P < 0.05). Image quality of VNE was lower than that of TNE without significant difference (P > 0.05). The active GIB source was identified

  8. Arteriovenous fistula of the superior gluteal artery as a complication of posterior iliac crest bone graft harvesting: 3D-CT angiography and arterial embolization

    OpenAIRE

    Kong, Chae-Gwan; Park, Jong-Beom; Won, Yoo-Dong; Riew, K. Daniel

    2009-01-01

    Superior gluteal artery injuries are rare, but potentially serious complications that occur during posterior iliac crest bone graft harvesting. The authors reported an arteriovenous fistula of the superior gluteal artery, which occurred as a complication during posterior iliac crest bone graft harvesting and was diagnosed with 3D-CT angiography, then treated with arterial embolization.

  9. [Image fusion of gated-SPECT and CT angiography in coronary artery disease. Importance of anatomic-functional correlation].

    Science.gov (United States)

    Nazarena Pizzi, M; Aguadé Bruix, S; Cuéllar Calabria, H; Aliaga, V; Candell Riera, J

    2010-01-01

    A 77-year old patient was admitted for acute coronary syndrome without ST elevation. His risk was stratified using the myocardial perfusion gated SPECT, mild inferior ischemia being observed. Thus, medical therapy was optimized and the patient was discharged. He continued with exertional dyspnea so a coronary CT angiography was performed. It revealed severe lesions in the proximal RCA. SPECT-CT fusion images correlated the myocardial perfusion defect with a posterior descending artery from the RCA, in a co-dominant coronary area. Subsequently, cardiac catheterism was indicated for his treatment. The current use of image fusion studies is limited to patients in whom it is difficult to attribute a perfusion defect to a specific coronary artery. In our patient, the fusion images helped to distinguish between the RCA and the circumflex artery as the culprit artery of ischemia. Copyright © 2010 Elsevier España, S.L. y SEMNIM. All rights reserved.

  10. Pulmonary embolism in pregnancy: comparison of pulmonary CT angiography and lung scintigraphy.

    LENUS (Irish Health Repository)

    Ridge, Carole A

    2012-02-01

    OBJECTIVE: The purpose of this study was to retrospectively compare the diagnostic adequacy of lung scintigraphy with that of pulmonary CT angiography (CTA) in the care of pregnant patients with suspected pulmonary embolism. MATERIALS AND METHODS: Patient characteristics, radiology report content, additional imaging performed, final diagnosis, and diagnostic adequacy were recorded for pregnant patients consecutively referred for lung scintigraphy or pulmonary CTA according to physician preference. Measurements of pulmonary arterial enhancement were performed on all pulmonary CTA images of pregnant patients. Lung scintigraphy and pulmonary CTA studies deemed inadequate for diagnosis at the time of image acquisition were further assessed, and the cause of diagnostic inadequacy was determined. The relative contribution of the inferior vena cava to the right side of the heart was measured on nondiagnostic CTA images and compared with that on CTA images of age-matched nonpregnant women, who were the controls. RESULTS: Twenty-eight pulmonary CTA examinations were performed on 25 pregnant patients, and 25 lung scintigraphic studies were performed on 25 pregnant patients. Lung scintigraphy was more frequently adequate for diagnosis than was pulmonary CTA (4% vs 35.7%) (p = 0.0058). Pulmonary CTA had a higher diagnostic inadequacy rate among pregnant than nonpregnant women (35.7% vs 2.1%) (p < 0.001). Transient interruption of contrast material by unopacified blood from the inferior vena cava was identified in eight of 10 nondiagnostic pulmonary CTA studies. CONCLUSION: We found that lung scintigraphy was more reliable than pulmonary CTA in pregnant patients. Transient interruption of contrast material by unopacified blood from the inferior vena cava is a common finding at pulmonary CTA of pregnant patients.

  11. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Chalumeau-Lemoine, Ludivine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine_khalil@yahoo.fr [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Pathological Angiogenesis and Vessel Normalization, Center for Interdisciplinary Research in Biology, CNRS UMR 7241/INSERM U1050, Collège de France, Paris (France); Prigent, Hélène [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Carette, Marie-France [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Fartoukh, Muriel [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Parrot, Antoine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France)

    2013-11-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting.

  12. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    International Nuclear Information System (INIS)

    Chalumeau-Lemoine, Ludivine; Khalil, Antoine; Prigent, Hélène; Carette, Marie-France; Fartoukh, Muriel; Parrot, Antoine

    2013-01-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting

  13. Diagnosis and screening of small hepatocellular carcinomas. Comparison of radionuclide imaging, ultrasound, computed tomography, hepatic angiography, and alpha 1-fetoprotein assay

    International Nuclear Information System (INIS)

    Takashima, T.; Matsui, O.; Suzuki, M.; Ida, M.

    1982-01-01

    Twenty-nine small (less than 5 cm) hepatocellular carcinomas in 18 patients were examined by radionuclide imaging (RN), ultrasound (US), computed tomography (CT), hepatic angiography, and serum alpha 1-fetoprotein (AFP) assay. Sensitivity was 39% with RN, 50% with US, 56% with CT, and 94% with angiography, including infusion hepatic angiography (IHA). Lesions larger than 3 cm could be detected by all of these methods; those between 2 and 3 cm were generally shown by US and CT but not RN. IHA was essential for diagnosis of lesions less than 2 cm, which were otherwise difficult or impossible to detect except with angiography. As a screening method, AFP was best, followed by US and CT. The authors recommend using AFP and US to minimize expense and radiation exposure. In questionable cases, IHA should be performed

  14. Treatment Effect of Balloon Pulmonary Angioplasty in Chronic Thromboembolic Pulmonary Hypertension Quantified by Automatic Comparative Imaging in Computed Tomography Pulmonary Angiography.

    Science.gov (United States)

    Zhai, Zhiwei; Ota, Hideki; Staring, Marius; Stolk, Jan; Sugimura, Koichiro; Takase, Kei; Stoel, Berend C

    2018-05-01

    Balloon pulmonary angioplasty (BPA) in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) can have variable outcomes. To gain more insight into this variation, we designed a method for visualizing and quantifying changes in pulmonary perfusion by automatically comparing computed tomography (CT) pulmonary angiography before and after BPA treatment. We validated these quantifications of perfusion changes against hemodynamic changes measured with right-sided heart catheterization. We studied 14 consecutive CTEPH patients (12 women; age, 70.5 ± 24), who underwent CT pulmonary angiography and right-sided heart catheterization, before and after BPA. Posttreatment images were registered to pretreatment CT scans (using the Elastix toolbox) to obtain corresponding locations. Pulmonary vascular trees and their centerlines were detected using a graph cuts method and a distance transform method, respectively. Areas distal from vessels were defined as pulmonary parenchyma. Subsequently, the density changes within the vascular centerlines and parenchymal areas were calculated and corrected for inspiration level differences. For visualization, the densitometric changes were displayed in color-coded overlays. For quantification, the median and interquartile range of the density changes in the vascular and parenchymal areas (ΔVD and ΔPD) were calculated. The recorded changes in hemodynamic parameters, including changes in systolic, diastolic, and mean pulmonary artery pressure (ΔsPAP, ΔdPAP, and ΔmPAP, respectively) and vascular resistance (ΔPVR), were used as reference assessments of the treatment effect. Spearman correlation coefficients were employed to investigate the correlations between changes in perfusion and hemodynamic changes. Comparative imaging maps showed distinct patterns in perfusion changes among patients. Within pulmonary vessels, the interquartile range of ΔVD correlated significantly with ΔsPAP (R = -0.58, P = 0.03),

  15. Computed tomography angiography in acute stroke (revisiting the 4Ps of imaging).

    Science.gov (United States)

    Varadharajan, Shriram; Saini, Jitender; Acharya, Ullas V; Gupta, Arun Kumar

    2016-02-01

    Imaging in acute stroke has traditionally focussed on the 4Ps-parenchyma, pipes, perfusion, and penumbra-and has increasingly relied upon advanced techniques including magnetic resonance imaging to evaluate such patients. However, as per European Magnetic Resonance Forum estimates, the availability of magnetic resonance imaging scanners for the general population in India (0.5 per million inhabitants) is quite low as compared to Europe (11 per million) and United States (35 per million), with most of them only present in urban cities. On the other hand, computed tomography (CT) is more widely available and has reduced scanning duration. Computed tomography angiography of cervical and intracranial vessels is relatively simpler to perform with extended coverage and can provide all pertinent information required in such patients. This imaging review will discuss relevant imaging findings on CT angiography in patients with acute ischemic stroke through illustrated cases. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Coronary artery imaging with 64-slice spiral CT in atrial fibrillation patients: initial experience

    International Nuclear Information System (INIS)

    Zhou Xuhui; Yan Chaogui; Xie Hongbo; Li Xiangmin; Li Ziping; Meng Quanfei; Chen Xing

    2008-01-01

    Objective: To discuss the clinical value of coronary artery imaging using 64-slice spiral CT in patient with atrial fibrillation. Methods: The images of 31 patients with atrial fibrillation who underwent contrast-enhanced CT coronary angiography were evaluated. The presence of stenosis on each segment of coronary arteries was recorded and their degree of stenosis was measured using the vessel analysis software. Ten patients additionally underwent conventional coronary angiography. The results of conventional coronary angiography were compared with CT coronary angiography of the 10 patients. Results: Image reconstruction was based on absolute timing. The image quality of 364 coronary vessel segments on the images from 31 patients was evaluated and defined as excellent, fine, moderate or poor. The image quality was excellent, fine, moderate and poor in 85, 41, 5, and 8 vessel segments respectively in patient group with heart rate between 47 beat per minent (bpm) and 69 bpm; and in 63, 16, 13, and 15 vessel segments respectively in patent group with heart rate between 70 bpm and 79 bpm;and in 46, 25, 23, and 24 vessel segments in patient group with heart rate between 80 bpm and 105 bpm. There was significant difference among the three patient groups (H=22.08, P<0.01). Comparison was carried out between CT angiographic findings and conventional angiographic findings of the 125 segments of the coronary arteries in the 10 patients who underwent conventional coronary angiography. The sensitivity and specificity of CT angiography for diagnosing vessel with significant coronary stenosis (≥50% narrowing) was 85.0% (17/20) and 95.2% (100/105), respectively. Positive predictive value was 77.3% (17/22), and negative predictive value was 97.1% (100/103). Coronary CTA underestimated the lesions of 3 vessel segments and overestimated the lesions of 5 vessel segments. Conclusion: Coronary artery imaging with 64-slice row CT had clinical value for patients with atrial fibrillation

  17. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  18. Patent foramen ovale in patients with pulmonary embolism: A prognostic factor on CT pulmonary angiography?

    Science.gov (United States)

    Zhang, Meng; Tan, Stephanie; Patel, Vishal; Zalta, Benjamin A; Shmukler, Anna; Levsky, Jeffrey M; Jain, Vineet R; Shaban, Nada M; Haramati, Linda B

    2017-12-02

    Patent foramen ovale (PFO) in patients with acute pulmonary embolism (PE) represents a risk factor for mortality, but this has not been evaluated for CT pulmonary angiography (CTPA). The purpose of the present study was to assess the relationship between PFO and mortality in patients with acute PE diagnosed on CTPA. This retrospective study included 268 adults [173 women, mean age 61 (range 22-98) years] diagnosed with acute PE on non-ECG-gated 64-slice CTPA in 2012 at our medical center. The images were reviewed for PFO by a panel of cardiothoracic radiologists with an average of 11 years of experience (range 1-25 years). CT signs of right heart strain and PE level were noted. Transthoracic echocardiograms (TTE), when available (n = 207), were reviewed for PFO by a cardiologist with subspecialty training in advanced imaging and with 3 years of experience. The main outcome was 30-day mortality. Fischer's exact test was utilized to compare mortality. PFO prevalence on CTPA was 22% (58/268) and 4% (9/207) on TTE. Overall 30-day mortality was 6% (16/268), 9% (5/58) for patients with PFO and 5% (11/210) for those without (p = 0.35). CT signs of right heart strain trended with higher mortality, but statistically significant only for hepatic vein contrast reflux [14% (6/44) vs 4% (10/224), p = 0.03]; right ventricular (RV) to left ventricular (LV) diameter ratio >1 [8% (13/156) vs RV:LV ≤ 1 3% (3/112), p = 0.07], septal bowing [10% (4/42) vs without 5% (12/226), p = 0.30]. PFO was demonstrated on CTPA in a proportion similar to the known population prevalence, while routine TTE was less sensitive. Mortality was non-significantly higher in patients with acute PE and PFO in this moderate-sized study. A larger study to answer this clinically important question is worthwhile. Copyright © 2017 Society of Cardiovascular Computed Tomography. All rights reserved.

  19. Angiography and interventional radiology of the kidneys; Angiographie und interventionelle Radiologie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W. [Heidelberg Univ. (Germany). Abt. Radiodiagnostik

    1999-05-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  20. Widening of coronary sinus in CT pulmonary angiography indicates right ventricular dysfunction in patients with acute pulmonary embolism

    International Nuclear Information System (INIS)

    Staskiewicz, Grzegorz; Czekajska-Chehab, Elzbieta; Trojanowska, Agnieszka; Drop, Andrzej; Przegalinski, Jerzy; Tomaszewski, Andrzej; Torres, Kamil; Torres, Anna; Maciejewski, Ryszard

    2010-01-01

    Right ventricular dysfunction (RVD) may occur in the course of acute pulmonary embolism (PE). Patients with RVD need more intensive treatment, and the prognosis is more severe. The aim of this study was to evaluate the usefulness of the measurement of the coronary sinus in the assessment of RVD in patients with acute PE and to compare it with other indicators of RVD. Retrospective assessment of 55 CT pulmonary angiography examinations with signs of acute PE was performed. Pulmonary artery systolic pressure (PASP) was echocardiographically assessed in all patients, and RVD was defined as PASP values greater than 30 mmHg. CT measurements included the size of the heart ventricles, mediastinal vessels and the width of the coronary sinus. Median width of the coronary sinus was 16 mm (range 12-24 mm) in patients with increased PASP and 10 mm (range 7-22 mm) in patients with normal PASP (p = 0.001). Best cut-off value was assessed to be 12.5 mm, with sensitivity 94% and specificity 75%. It was characterised by the largest area under ROC curve (0.82) among analysed parameters. Width of the coronary sinus seems to be a promising parameter for identification of RVD in patients with acute PE. A prospective study should be undertaken to further assess its clinical and prognostic applicability. (orig.)

  1. Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque - a comparison with histology

    International Nuclear Information System (INIS)

    Puchner, Stefan B.; Ferencik, Maros; Maurovich-Horvat, Pal; Nakano, Masataka; Otsuka, Fumiyuki; Virmani, Renu; Kauczor, Hans-Ulrich; Hoffmann, Udo; Schlett, Christopher L.

    2015-01-01

    To evaluate whether iterative reconstruction algorithms improve the diagnostic accuracy of coronary CT angiography (CCTA) for detection of lipid-core plaque (LCP) compared to histology. CCTA and histological data were acquired from three ex vivo hearts. CCTA images were reconstructed using filtered back projection (FBP), adaptive-statistical (ASIR) and model-based (MBIR) iterative algorithms. Vessel cross-sections were co-registered between FBP/ASIR/MBIR and histology. Plaque area 2 : 5.78 ± 2.29 vs. 3.39 ± 1.68 FBP; 5.92 ± 1.87 vs. 3.43 ± 1.62 ASIR; 6.40 ± 1.55 vs. 3.49 ± 1.50 MBIR; all p < 0.0001). AUC for detecting LCP was 0.803/0.850/0.903 for FBP/ASIR/MBIR and was significantly higher for MBIR compared to FBP (p = 0.01). MBIR increased sensitivity for detection of LCP by CCTA. Plaque area <60 HU in CCTA was associated with LCP in histology regardless of the reconstruction algorithm. However, MBIR demonstrated higher accuracy for detecting LCP, which may improve vulnerable plaque detection by CCTA. (orig.)

  2. Comparative evaluation of cerebral aneurysms with selective arterially enhanced CT and DSA

    International Nuclear Information System (INIS)

    Vanderschelden, P.; Flandroy, P.; Dondelinger, R.F.; Martin, D.; Lenelle, J.

    1998-01-01

    The purpose of our study was to compare selective arterially enhanced spiral computed tomographs (ACT) with digital subtraction angiographies (DSA) in the presurgical assessment of cerebral aneurysms. A total of 24 aneurysms in 18 patients were explored in a prospective study by ACT and DSA, using an interactive combined CT-angiography suite. Dimensions of the aneurysm, its relation to the parent vessel, and the aneurysmal index were defined on DSA and on surface-shaded display of 3D reformatted images obtained from ACT. Results were correlated with surgical findings. Three aneurysms suspected on DSA were not confirmed by ACT. One fusiform aneurysm suspected on DSA corresponded to a sacciform aneurysm on ACT. Surgical findings confirmed 20 sacciform aneurysms. The aneurysmal index could be measured in all 20 cases of sacciform aneurysms on ACT and could not be determined with confidence in 55 % of the cases on DSA. DSA and ACT gave identical results in 35 % of cases. In 10 %, the index measured by ACT was superior to that determined by DSA for aneurysms which had a diameter of less than 3 mm. In conclusion, the combination of DSA and ACT improved the results of DSA alone. ACT is a reliable method to measure the aneurysmal index in aneurysms with a diameter superior to 3 mm. (orig.)

  3. Low-dose prospectively electrocardiogram-gated axial dual-source CT angiography in patients with pulsatile bilateral bidirectional Glenn Shunt: an alternative noninvasive method for postoperative morphological estimation.

    Directory of Open Access Journals (Sweden)

    Xiaopeng Ji

    Full Text Available To explore the clinical value of low-dose prospectively electrocardiogram-gated axial dual-source CT angiography (low-dose PGA scanning, CTA in patients with pulsatile bilateral bidirectional Glenn shunt (bBDG as an alternative noninvasive method for postoperative morphological estimation.Twenty patients with pulsatile bBDG (mean age 4.2±1.6 years underwent both low-dose PGA scanning and conventional cardiac angiography (CCA for the morphological changes. The morphological evaluation included the anatomy of superior vena cava (SVC and pulmonary artery (PA, the anastomotic location, thrombosis, aorto-pulmonary collateral circulation, pulmonary arteriovenous malformations, etc. Objective and subjective image quality was assessed. Bland-Altman analysis and linear regression analyses were used to evaluate the correlation on measurements between CTA and CCA. Effective radiation dose of both modalities was calculated.The CT attenuation value of bilateral SVC and PA was higher than 300 HU. The average subjective image quality score was 4.05±0.69. The morphology of bilateral SVC and PA was displayed completely and intuitively by CTA images. There were 24 SVC above PA and 15 SVC beside PA. Thrombosis was found in 1 patient. Collateral vessels were detected in 13 patients. No pulmonary arteriovenous malformation was found in our study. A strong correlation (R2>0.8, P0.The mean effective dose of CTA and CCA was 0.50±0.17 mSv and 4.85±1.34 mSv respectively.CT angiography with a low-dose PGA scanning is an accurate and reliable noninvasive examination in the assessment of morphological changes in patients with pulsatile bBDG.

  4. Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?

    International Nuclear Information System (INIS)

    Noergaard, B.L.; Jensen, J.M.; Leipsic, J.

    2015-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is the gold standard for lesion-specific decisions on coronary revascularization in patients with stable coronary artery disease (CAD). Current guidelines recommend non-invasive functional or anatomic testing as a gatekeeper to the catheterization laboratory. However, the ''holy grail'' in non-invasive testing of CAD is to establish a single test that quantifies both coronary lesion severity and the associated ischemia. Most evidence to date of such a test is based on the addition of computational analysis of FFR to the anatomic information obtained from standard-acquired coronary CTA data sets at rest (FFR CT ). This review summarizes the clinical evidence for the use of FFR CT in stable CAD in context to the diagnostic performance of other non-invasive testing modalities. (orig.)

  5. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, P.D. [Sheffield Univ. (United Kingdom). Academic Dept. of Radiology; Beveridge, C.J.; Gholkar, A. [Newcastle General Hospital, Newcastle upon Tyne (United Kingdom). Dept. of Neuroradiology

    1997-09-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.).

  6. Angiography in non-traumatic brain haematoma. An analysis of 100 cases

    International Nuclear Information System (INIS)

    Griffiths, P.D.; Beveridge, C.J.; Gholkar, A.

    1997-01-01

    Purpose: The primary purpose of this project was to study the anatomical characteristics of intracerebral haematoma (ICH) in order to determine features that may negate the need for angiography in some patients. Material and Methods: The study was prospective and designed to investigate the underlying cause of non-traumatic ICH in 100 cases assessed by conventional angiography. Patients were excluded if there was a history of trauma or known pre-existing brain abnormality. All patients were examined with CT and angiography within 4 days of the ictus. Results: Ruptured aneurysms or arteriovenous malformations (AVMs) were diagnosed on the initial angiogram in 49% of cases: 27 AVMs and 22 aneurysms. One case of superior sagittal sinus thrombosis was also detected. Vascular abnormalities were found most frequently in the under-40 age group and in cases in which subarachnoid haemorrhage, intraventricular haemorrhage or extracerebral haematoma accompanied the ICH. The temporal lobe was the most frequent anatomical location (37%). When a temporal lobe haematoma extended into the Sylvian fissure from the inferior pole of the temporal lobe or when it was associated with subarachnoid haemorrhage, structural abnormalities were found in over 90% of cases. Conclusions: There are groups of patients with ICH in whom the CT features are highly suggestive of AVM or aneurysm rupture. If the initial angiography is negative in these cases, careful follow up by repeat angiography and/or MR imaging is essential. However, potentially treatable abnormalities cannot be excluded with certainty by the distribution of the haematoma on CT alone, even if there is a history of pre-existing hypertension. (orig.)

  7. Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting.

    Science.gov (United States)

    André, Florian; Fortner, Philipp; Vembar, Mani; Mueller, Dirk; Stiller, Wolfram; Buss, Sebastian J; Kauczor, Hans-Ulrich; Katus, Hugo A; Korosoglou, Grigorios

    The aim of this study was to assess the potential for radiation dose reduction using knowledge-based iterative model reconstruction (K-IMR) algorithms in combination with ultra-low dose body mass index (BMI)-adapted protocols in coronary CT angiography (coronary CTA). Forty patients undergoing clinically indicated coronary CTA were randomly assigned to two groups with BMI-adapted (I: quality was significantly better in the ULD group using K-IMR CR 1 compared to FBP, iD 2 and iD 5 in the LD group, resulting in fewer non-diagnostic coronary segments (2.4% vs. 11.6%, 9.2% and 6.1%; p quality compared to LD protocols with FBP or hybrid iterative algorithms. Therefore, K-IMR allows for coronary CTA examinations with high diagnostic value and very low radiation exposure in clinical routine. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review

    International Nuclear Information System (INIS)

    Abdullah, Kamarul Amin; McEntee, Mark F.; Reed, Warren; Kench, Peter L.

    2016-01-01

    The aim of this systematic review is to evaluate the radiation dose reduction achieved using iterative reconstruction (IR) compared to filtered back projection (FBP) in coronary CT angiography (CCTA) and assess the impact on diagnostic image quality. A systematic search of seven electronic databases was performed to identify all studies using a developed keywords strategy. A total of 14 studies met the criteria and were included in a review analysis. The results showed that there was a significant reduction in radiation dose when using IR compared to FBP (P 0.05). The mean ± SD difference of image noise, signal-noise ratio (SNR) and contrast-noise ratio (CNR) were 1.05 ± 1.29 HU, 0.88 ± 0.56 and 0.63 ± 1.83 respectively. The mean ± SD percentages of overall image quality scores were 71.79 ± 12.29% (FBP) and 67.31 ± 22.96% (IR). The mean ± SD percentages of coronary segment analysis were 95.43 ± 2.57% (FBP) and 97.19 ± 2.62% (IR). In conclusion, this review analysis shows that CCTA with the use of IR leads to a significant reduction in radiation dose as compared to the use of FBP. Diagnostic image quality of IR at reduced dose (30–41%) is comparable to FBP at standard dose in the diagnosis of CAD.

  9. Coexistent coronary artery disease or myocardial bridging in patients with hypertrophic cardiomyopathy using coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hwan; Chun, Eun Ju; Kim, Yeo Koon; Yoo, Jin Young; Choi, Sang Il; Choi, Dong Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-07-15

    To evaluate the prevalence of coexistent coronary artery disease (CAD) or myocardial bridging (MB) in patients with hypertrophic cardiomyopathy (HCM) using coronary CT angiography (CCTA) and assess the role of CCTA. The prevalence of obstructive CAD (> 50% luminal reduction) and MB (partial and full encasement) were assessed in 150 patients with HCM diagnosed by clinical findings, electrocardiography, and echocardiography of 19588 consecutive patients who underwent CCTA for suspected CAD. The overall feasibility of coronary artery visualization was 98.9% with CCTA. In patients with HCM, the prevalence of obstructive CAD and MB (14.7% partial and 28.0% full encasement) were 23.3% and 42.7%, respectively. Age, hypertension, family history of premature CAD, Framingham risk score and severe chest pain were associated with CAD, whereas male gender and septal type were associated with MB (all p < 0.05). In comparison to invasive coronary angiography (n = 37), the diagnostic accuracy of CCTA for the detection of CAD and full encasement MB was 89.2% and 86.5%, respectively. One-quarter of patients with HCM had coexistent obstructive CAD or full encasement MB. CCTA can be a feasible and accurate noninvasive imaging modality for the detection of CAD and MB in patients with HCM.

  10. Diagnostic performance of calcification-suppressed coronary CT angiography using rapid kilovolt-switching dual-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Yunaga, Hiroto; Ohta, Yasutoshi; Kitao, Shinichiro; Ogawa, Toshihide [Tottori University, Division of Radiology, Department of Pathophysiological Therapeutic Science, Faculty of Medicine, Yonago City, Tottori (Japan); Kaetsu, Yasuhiro [Kakogawa Higashi Hospital, Department of Cardiology, Kakogawa (Japan); Watanabe, Tomomi; Furuse, Yoshiyuki; Yamamoto, Kazuhiro [Tottori University, Division of Cardiology, Department of Molecular Medicine and Therapeutics, Faculty of Medicine, Yonago (Japan)

    2017-07-15

    Multi-detector-row computed tomography angiography (MDCTA) plays an important role in the assessment of patients with suspected coronary artery disease. However, MDCTA tends to overestimate stenosis in calcified coronary artery lesions. The aim of our study was to evaluate the diagnostic performance of calcification-suppressed material density (MD) images produced by using a single-detector single-source dual-energy computed tomography (ssDECT). We enrolled 67 patients with suspected or known coronary artery disease who underwent ssDECT with rapid kilovolt-switching (80 and 140 kVp). Coronary artery stenosis was evaluated on the basis of MD images and virtual monochromatic (VM) images. The diagnostic performance of the two methods for detecting coronary artery disease was compared with that of invasive coronary angiography as a reference standard. We evaluated 239 calcified segments. In all the segments, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy for detecting significant stenosis were respectively 88%, 88%, 75%, 95% and 88% for the MD images, 91%, 71%, 56%, 95% and 77% for the VM images. PPV was significantly higher on the MD images than on the VM images (P < 0.0001). Calcification-suppressed MD images improved PPV and diagnostic performance for calcified coronary artery lesions. (orig.)

  11. Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

    International Nuclear Information System (INIS)

    Shen, Junlin; Du, Xiangying; Guo, Daode; Cao, Lizhen; Gao, Yan; Bai, Mei; Li, Pengyu; Liu, Jiabin; Li, Kuncheng

    2013-01-01

    Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17–35.08 HU) and Group 3 (34.34–35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose

  12. Prospective electrocardiogram-gated axial 64-detector computed tomographic angiography vs retrospective gated helical technique to assess coronary artery bypass graft anastomosis. Comparison of image quality and patient radiation dose

    International Nuclear Information System (INIS)

    Machida, Haruhiko; Masukawa, Ai; Tanaka, Isao; Fukui, Rika; Suzuki, Kazufumi; Ueno, Eiko; Kodera, Kojiro; Nakano, Kiyoharu; Shen, Y.

    2010-01-01

    In the present study the effective dose and image quality at distal anastomoses were retrospectively compared between prospective electrocardiogram (ECG)-gated axial and retrospective ECG-gated helical techniques on 64-detector computed tomographic (CT) angiography following coronary artery bypass graft surgery. Following bypass surgery, 52 patients with a heart rate <65 beats/min underwent CT angiography: 26 patients each with prospective and retrospective ECG gating techniques. The effective dose was compared between the 2 groups using a 4-point scale (4, excellent; 1, poor) to grade the quality of curved multiplanar reformation images at distal anastomoses. Patient characteristics of the 2 groups were well matched, and the same CT scan parameters were used for both, except for the interval between surgery and CT examination, tube current, and image noise index. Image quality scores did not differ significantly (3.26±0.95 vs 3.35±0.87; P=0.63), but the effective dose was significantly lower in the prospective (7.3±1.8 mSv) than in the retrospective gating group (23.6±4.5 mSv) (P<0.0001). Following bypass surgery, 64-detector CT angiography using prospective ECG gating is superior to retrospective gating in limiting the radiation dose and maintaining the image quality of distal anastomoses. (author)

  13. Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging.

    Science.gov (United States)

    Suntharalingam, Saravanabavaan; Mikat, Christian; Stenzel, Elena; Erfanian, Youssef; Wetter, Axel; Schlosser, Thomas; Forsting, Michael; Nassenstein, Kai

    2017-01-01

    To evaluate the image quality and radiation dose of submillisievert standard-pitch CT pulmonary angiography (CTPA) with ultra-low dose contrast media administration in comparison to standard CTPA. Hundred patients (56 females, 44 males, mean age 69.6±15.4 years; median BMI: 26.6, IQR: 5.9) with suspected pulmonary embolism were examined with two different protocols (n = 50 each, group A: 80 kVp, ref. mAs 115, 25 ml of contrast medium; group B: 100 kVp, ref. mAs 150, 60 ml of contrast medium) using a dual-source CT equipped with automated exposure control. Objective and subjective image qualities, radiation exposure as well as the frequency of pulmonary embolism were evaluated. There was no significant difference in subjective image quality scores between two groups regarding pulmonary arteries (p = 0.776), whereby the interobserver agreement was excellent (group A: k = 0.9; group B k = 1.0). Objective image analysis revealed that signal intensities (SI), signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the pulmonary arteries were equal or significantly higher in group B. There was no significant difference in the frequency of pulmonary embolism (p = 0.65). Using the low dose and low contrast media protocol resulted in a radiation dose reduction by 71.8% (2.4 vs. 0.7 mSv; pcontrast agent volume can obtain sufficient image quality to exclude or diagnose pulmonary emboli while reducing radiation dose by approximately 71%.

  14. Three-dimensional helical (spiral) CT angiography. Visualization of vessels in the maxillofacial regions

    International Nuclear Information System (INIS)

    Hanawa, Shigeo; Sakamoto, Hidetomo; Mori, Shin-ichiro; Kagawa, Toyohiro; Seze, Ryosuke; Ishioka, Hisakazu; Tashiro, Himiko; Ogawa, Kazuhisa; Wada, Tadako

    1998-01-01

    Authors performed the contrast helical CT for tumors on the maxillofacial regions, and reconstituted these data into the three-dimensional helical (spiral) CT angiography (CTA). Furthermore the conditions of photographing and the clinical significance of CTA were discussed. The subjects were 24 cases (including 13 of malignant tumors, 4 of benign tumors, 4 of inflammation and 3 of malformations), to which the contrast helical CT was performed transvenously. The photographing condition was set in principal to 140 kV of the tube voltage, 160 (200) mA of the tube current, 3 mm of the X-ray beam width, 3 mm/sec (pitch=1) of the turn-table moving speed. The relationship between the beam width and the pitch was determined by the phantom experiments. The scanning was carried out maximally for continuous 60 sec as the scanning time of a turn/sec. Of all cases, CTA visualized three-dimensionally vessels, but it was hard in the total carotid arteries and the internal-external carotid arteries. Authors analyzed the axial and the multiplanar reconstitution (MPR) images as the two-dimensional display, and the surface rendering (SR), the volume rendering and the maximum intensity projections (MIP) as the three-dimensional display. The axial and MPR image of the facial arteries and the lingual arteries as the branched vessels from the external carotid arteries were recognized easily. By SR, it was easily to understand the anatomical relationship among vessels, gnathic bone and cervical vertebrae, and by MIP sufficiently observe the concentration dependent calcification of the vessel walls. Three-dimensional CTA is very useful to get the three-dimensional visual information about the anatomical structures of the maxillofacial regions which is necessary for oral surgeons to plan the pre-operational strategies. (K.H.)

  15. CT coronary angiography in patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Kovacs, A.; Sommer, T.; Leiss, A.; Naehle, P.; Schild, H.; Flacke, S.; Probst, C.; Welz, A.

    2005-01-01

    Purpose: Reliable visualization of the coronary arteries with multislice spiral CT angiography (MSCTA) in patients with atrial fibrillation (AF) remains a challenge despite retrospective ECG gating. A recently developed new algorithm automatically compensates dynamic changes in the heart rate during the scan, thus reducing misregistration and motion artifacts. The HeartBeat-RT algorithm combines a fixed percent delay determined from the first R wave and the fixed offset delay based on the second R wave in the ECG cycle. The purpose of this study was to find out the optimal reconstruction window in MSCTA in patients with AF for each of the three major coronary arteries during the cardiac cycle. Materials and methods: 20 patients with permanent AF were imaged on a 16-slice scanner (slice collimation: 16 x 0.75 mm; rotation time 0.42 s; 140 kV; 380 mAs; 120 ml Ultravist 370 registered i.v.). The patients had not received any previous drugs for heart frequency regulation. Acquisition was started after bolus tracking of a biphasic bolus of 120 ml Ultravist 370 injected intravenously. Each coronary segment was reconstructed at 0%-90% of the cardiac cycle in increments of 10%. For image analysis we used coronary segments as defined by the American Heart Association. Two blinded independent readers assessed the image quality in terms of visibility and artifacts (five-point rating scale 1=very poor, 2=poor, 3=fair, 4=good and 5=excellent) and the degree of stenosis (five-point rating scale 1=0%, 2=1%-49%, 3=50%-74%, 4=75%-99%, 5=100%) on axial slices, multiplanar reconstructions and three-dimensional volume-rendered images. (orig.)

  16. Impact of Collateral Status Evaluated by Dynamic Computed Tomographic Angiography on Clinical Outcome in Patients With Ischemic Stroke

    NARCIS (Netherlands)

    van den Wijngaard, Ido R.; Boiten, Jelis; Holswilder, Ghislaine; Algra, Ale; Dippel, Diederik W J; Velthuis, Birgitta K.; Wermer, Marieke J H; van Walderveen, Marianne A A

    2015-01-01

    BACKGROUND AND PURPOSE—: Status of collateral circulation is a strong predictor of outcome after acute ischemic stroke. Our aim was to compare the predictive value of strategies for collateral blood flow assessment with dynamic computed tomographic angiography (CTA) and conventional single-phase CT

  17. Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging

    NARCIS (Netherlands)

    Peters, R. J.; Kok, W. E.; Pasterkamp, G.; von Birgelen, C.; Prins, M. [=Martin H.; Serruys, P. W.

    2000-01-01

    AIMS: To assess the value of videodensitometric quantification of the coronary lumen after angioplasty by comparison to two other techniques of coronary artery lumen quantification. METHODS AND RESULTS: Videodensitometric quantitative angiography, edge detection quantitative angiography and 30 MHz

  18. SPECT-CT in the diagnosis of coronary artery disease; SPECT-CT in der Diagnostik der koronaren Herzerkrankung

    Energy Technology Data Exchange (ETDEWEB)

    Hacker, M. [Klinik und Poliklinik fuer Nuklearmedizin, Klinikum der Univ. Muenchen (Germany)

    2006-09-15

    Two-dimensional invasive coronary angiography (ICA), although showing high temporal and spatial resolution, is neither able to predict the physiologic relevance of a stenosis nor able to determine the prognosis of both symptomatic and asymptomatic patients. Therefore, the ICA can hardly represent the sole gold standard in clinical decision making. Additionally, the small but distinct morbidity and mortality rate of this method and the inconvenience of patients undergoing ICA have strengthened the search for a non-invasive alternative. Recent publications have shown high accuracy for spiral computed tomography (MDCT) angiography acquired with a 64-slice CT scanner compared to ICA in detecting 'obstructive' coronary artery disease, defined as stenosis of more than 50%. Otherwise, although well known limitations of MDCT like motion artifacts or severe vessel calcifications could be clearly reduced with the newest scanner generation, this technique lacks of delivering exact lumen quantification compared to ICA in a clinical setting. Furthermore, there is evidence that exact quantification of coronary artery stenoses is of minor impact on clinical decision making, if lesion location and functional status are known. A first publication showed that combined imaging of MDCT angiography and PET myocardinal perfusion scanning with [{sup 13}N]ammonia was feasible with an integrated PET/CT scanner and reported high sensitivity and specificity to detect hemodynamically relevant coronary artery stenoses compared to the combination of PET plus ICA. However, PET perfusion tracers are not widely available at present and the well accepted reference for detecting myocardial ischemia, based on numerous publications, is myocardial perfusion SPECT (MPI). MPI is an established method for the non-invasive assessment of functional significance of coronary stenoses and delivers valuable information for risk stratification. Patients with stable angina and normal stress sestamibi

  19. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    Science.gov (United States)

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  20. Role of multidetector CT angiography in the evaluation of suspected mesenteric ischemia

    International Nuclear Information System (INIS)

    Barmase, Meghna; Kang, Mandeep; Wig, Jaidev; Kochhar, Rakesh; Gupta, Rajesh; Khandelwal, Niranjan

    2011-01-01

    Objective: To assess the role of multidetector CT angiography (MDCTA) in the diagnosis of acute mesenteric ischemia (AMI) and to compare the diagnostic utility of axial images with reconstructed images. Materials and methods: In this Institute Review Board approved prospective study, MDCTA was performed on 31 patients who presented with the clinical suspicion of AMI (25M; 6F, age range: 16–73 years). Axial and reconstructed images of each patient were evaluated independently by two radiologists for evidence of bowel wall thickening, abnormal mucosal enhancement, bowel dilatation or obstruction, mesenteric stranding, ascites, solid organ infarcts, pneumatosis intestinalis or porto-mesenteric gas, and mesenteric arterial or venous occlusion. MDCT findings were correlated with the surgical findings and clinical outcome. Patients were later divided into two groups: a study group of patients with proven AMI and a control group of patients with an alternate diagnosis, for the purpose of statistical analysis. Results: AMI was correctly diagnosed in all 16 patients on MDCTA (100% sensitivity and specificity) of whom nine patients underwent surgical exploration. Three patients expired before surgery and the remaining 5 patients were proven based on positive clinical and laboratory findings. Mesenteric arterial occlusion was seen in 7 patients while 5 patients had portomesenteric venous thrombosis. Reconstructed images using minimum intensity projection, volume rendering and multiplanar volume reconstruction were found to perform better for the detection of vascular abnormalities and improved the diagnostic confidence of both radiologists in the evaluation of bowel and mesenteric abnormalities. Conclusion: MDCTA is an effective non-invasive modality for the diagnosis of mesenteric ischemia.

  1. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Lundin, Margareta; Liden, Mats; Geijer, Haakan; Andersson, Torbjoern [Dept. of Radiology, Oerebro Univ. Hospital, Oerebro Univ., Oerebro (Sweden)], E-mail: margareta.lundin@orebroll.se; Magnuson, Anders [Clinical Epidemiology and Biostatistic Unit, Oerebro Univ. Hospital, Oerebro (Sweden); Mohammed, Ahmed Abdulilah [Dept. of Radiology, Linkoeping Univ. Hospital, Linkoeping (Sweden); Persson, Anders [CMIV Center for Medical Image Science and Visualization, Linkoeping (Sweden)

    2012-07-15

    Background. Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. Purpose. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Material and Methods. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. Results. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Conclusion. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.

  2. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study.

    Science.gov (United States)

    Lundin, Margareta; Lidén, Mats; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Geijer, Håkan; Andersson, Torbjörn; Persson, Anders

    2012-07-01

    Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system.

  3. Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study

    International Nuclear Information System (INIS)

    Lundin, Margareta; Liden, Mats; Geijer, Haakan; Andersson, Torbjoern; Magnuson, Anders; Mohammed, Ahmed Abdulilah; Persson, Anders

    2012-01-01

    Background. Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation. Purpose. To compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model. Material and Methods. Thirty patients referred for evaluation of hematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard. Results. The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition. Conclusion. Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However, the difference is smaller with the new compared to the older system

  4. CT myocardial perfusion imaging. Ready for prime time?

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P.; Celeng, Csilla [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Ashley River Tower, Heart and Vascular Center, Charleston, SC (United States)

    2018-03-15

    The detection of functional coronary artery stenosis with coronary CT angiography (CCTA) is suboptimal. Additional CT myocardial perfusion imaging (CT-MPI) may be helpful to identify patients with myocardial ischaemia in whom coronary revascularization therapy would be beneficial. CT-MPI adds incremental diagnostic and prognostic value over obstructive disease on CCTA. It allows for the quantitation of myocardial blood flow and calculation of coronary flow reserve and shows good correlation with {sup 15}O-H{sub 2}O positron emission tomography and invasive fractional flow reserve. In addition, patients prefer CCTA/CT-MPI over SPECT, MRI and invasive coronary angiography. CT-MPI is ready for clinical use for detecting myocardial ischaemia caused by obstructive disease. Nevertheless, the clinical utility of CT-MPI to identify ischaemia in patients with non-obstructive/microvascular disease still has to be established. (orig.)

  5. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  6. Clinical application of gadolinium-enhanced three-dimensional pulmonary MR angiography

    International Nuclear Information System (INIS)

    Takano, Katsuyuki

    1999-01-01

    Twenty-nine patients with suspected pulmonary lesions, and three normal volunteers, underwent gadolinium-enhanced three-dimensional (3D) pulmonary MR angiography (MRA). The MRA were obtained during intravenous administration of gadolinium-based contrast material, in a single breath-hold. Conspicuity of the normal pulmonary segmental arteries was estimated on the MRA. Abnormal findings such as ''vascular involvement'', ''abnormal connection'', stenosis'', or ''dilatation'' on the MRA were compared with those on conventional angiography or CT. Normal pulmonary segmental arteries, except for A 4,5,6,8and9 of the left pulmonary artery, could be clearly visualized. Blind reading of four different findings lead to characteristic findings for each pulmonary disease that can be aid in their differential diagnoses. This technique shows promise as a noninvasive diagnosis of lung diseases. (author)

  7. Evaluation of intra-aortic CT angiography performances for the visualisation of spinal vascular malformations' angioarchitecture

    International Nuclear Information System (INIS)

    Clarencon, Frederic; Gabrieli, Joseph; Chiras, Jacques; Di Maria, Federico; Sourour, Nader-Antoine; Shotar, Eimad; Cormier, Evelyne; Fahed, Robert; Nouet, Aurelien; Cornu, Philippe

    2016-01-01

    To evaluate the performances of the CT-angiography by direct intra-aortic contrast media injection (IA-CTA) for spinal vascular malformations (SVMs)' imaging. Thirteen patients (8 males, 5 females, mean age: 56 y) with suspected SVM underwent IA-CTAs by direct intra-aortic iodinated contrast media injection (5 cc/s; 100 cc) via an arterial femoral or humeral access. Two independent observers evaluated the angioarchitecture of the SVMs and the visualisation of both the Adamkiewicz artery and the anterior spinal artery. Then a consensus was obtained between the 2 reviewers; the results of the IA-CTA were finally compared with those of the full spinal DSA evaluated in consensus. The IA-CTA was feasible in all cases and depicted the SVM in all except one case (92 %). Interrater agreement was good for the location of the SVMs' level. Intermodality (IA-CTA/DSA) agreement was excellent for the level and side of the shunt point, as well as for the SVM subtype evaluation. In 77 % of the cases, the Adamkiewicz artery was satisfactorily seen at the same time on IA-CTA. IA-CTA is a new technique that seems helpful to reach a better understanding of SMVs and may help to tailor more precisely their treatment. (orig.)

  8. Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries.

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    Full Text Available PURPOSE: To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol, compared with single coronary CTA. MATERIALS AND METHODS: 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47 underwent combined heart, neck, and head CTA using prospectively ECG-triggered high-pitch spiral (Flash scan protocol with a single-phase intravenous injection of iodinated contrast and saline flush; Group 2 (n = 51 underwent single coronary CTA with Flash scan protocol; and Group 3 (n = 53 underwent single coronary CTA with prospective sequence scan protocol. All patients were examined on a dual source CT (Definition FLASH. The image quality was determined for each CT study. RESULTS: Patients of scanning protocol Group 1, 2, and 3 showed no significant differences in age, sex, heart rates, and BMI. Evaluation of coronary artery image quality showed comparable results in the three scanning protocol groups on a per patient-based analysis. In group 1, image quality was found to be sufficient to be diagnostic in all arterial segments of carotid arteries. The mean dose-length product (DLP for group 1 was 256.3±24.5 mGy×cm and was significantly higher in comparison with group 2 (93.4±19.9 mGy×cm; p < 0.001. However, there was no significant difference of DLP between group 1 and group 3 (254.1±69.9 mGy×cm. CONCLUSIONS: The combined heart, neck, and head arteries scan using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol in 1 single examination resulted in an excellent opacification of the aorta, the carotid arteries, and the coronary arteries and provided a good image quality with low radiation dose.

  9. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    International Nuclear Information System (INIS)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker; Floegel, Thomas; Kitzler, Hagen H.; Alexandrov, Andrei V.

    2016-01-01

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r s = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  10. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Floegel, Thomas [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Kitzler, Hagen H. [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Alexandrov, Andrei V. [The University of Tennessee Health Science Center, Department of Neurology, Memphis, TN (United States)

    2016-09-15

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r{sub s} = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  11. Spiral CT for evaluation of chest trauma; Spiral-CT beim Thoraxtrauma

    Energy Technology Data Exchange (ETDEWEB)

    Roehnert, W. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik; Weise, R. [Universitaetsklinikum Dresden (Germany). Inst. und Poliklinik fuer Radiologische Diagnostik

    1997-07-01

    After implementation of spiral CT in our department, we carried out an analysis for determining anew the value of CT as a modality of chest trauma diagnosis in the emergency department. The retrospective study covers a period of 10 months and all emergency patients with chest trauma exmined by spiral CT. The major lesions of varying seriousness covered by this study are: pneumothorax, hematothorax, pulmonary contusion or laceration, mediastinal hematoma, rupture of a vessel, injury of the heart and pericardium. The various fractures are not included in this study. In many cases, spiral CT within relatively short time yields significant diagnostic findings, frequently saving additional angiography. A rigid diagnostic procedure cannot be formulated. Plain-film chest radiography still remains a diagnostic modality of high value. (Orig.) [Deutsch] Nach Einfuehrung der Spiral-CT in unserer Einrichtung versuchten wir, den Stellenwert der Computertomographie in der Notfalldiagnostik des Thoraxtraumas neu zu bestimmen. Dazu wurden retrospektiv ueber einen Zeitraum von 10 Monaten alle mittels Spiral-CT untersuchten Notfallpatienten mit Thoraxverletzungen ausgewertet. Im Vordergrund standen folgende Befunde unterschiedlichen Schweregrades: Pneumothorax, Haematothorax, Lungenkontusion/-lazeration, Mediastinalhaematom, Gefaessruptur, Herz- und Herzbeutelverletzung. Auf die unterschiedlichen Frakturen wird bewusst nicht naeher eingegangen. In vielen Faellen liefert die Spiral-CT mit relativ geringem Zeitaufwand wesentliche diagnostische Aussagen. Haeufig kann auf eine Angiographie verzichtet werden. Ein starres diagnostisches Stufenschema laesst sich nicht definieren. Die Thoraxuebersichtsaufnahme besitzt einen unveraendert hohen Stellenwert. (orig.)

  12. Coronary Computed Tomography Angiography Derived Fractional Flow Reserve and Plaque Stress

    DEFF Research Database (Denmark)

    Nørgaard, Bjarne Linde; Leipsic, Jonathon; Koo, Bon-Kwon

    2016-01-01

    Fractional flow reserve (FFR) measured during invasive coronary angiography is an independent prognosticator in patients with coronary artery disease and the gold standard for decision making in coronary revascularization. The integration of computational fluid dynamics and quantitative anatomic...... and physiologic modeling now enables simulation of patient-specific hemodynamic parameters including blood velocity, pressure, pressure gradients, and FFR from standard acquired coronary computed tomography (CT) datasets. In this review article, we describe the potential impact on clinical practice...... and the science behind noninvasive coronary computed tomography (CT) angiography derived fractional flow reserve (FFRCT) as well as future applications of this technology in treatment planning and quantifying forces on atherosclerotic plaques....

  13. Ectopic origin of bronchial arteries: assessment with multidetector helical CT angiography

    International Nuclear Information System (INIS)

    Hartmann, Ieneke J.C.; Remy-Jardin, Martine; Menchini, Laura; Teisseire, Antoine; Khalil, Chadi; Remy, Jacques

    2007-01-01

    The purpose of this study was to determine non-invasively the frequency of ectopic bronchial arteries (BA) (i.e., bronchial arteries originating at a level of the descending aorta other than T5-T6 or from any aortic collateral vessel) on multidetector-row CT angiograms (CTA) obtained in patients with hemoptysis. Over a 5-year period (2000-2005), 251 consecutive patients with hemoptysis underwent multidetector-row CT angiography of the thorax. From this population, 37 patients were excluded because of a suboptimal CTA examination (n = 19), the presence of extensive mediastinal disease (n = 15) or severe chest deformation (n = 3) precluding any precise analysis of the bronchial arteries at CTA. Our final study group included 214 patients who underwent a thin-collimated CT angiogram (contrast agent: 300 to 350 mg/ml) on a 4- (n = 56), 16- (n = 119) and 64- (n = 39) detector-row scanner. The site of origin and distribution of bronchial arteries were analyzed on transverse CT scans, maximum intensity projections and volume-rendered images. The site of the ostium of a bronchial artery was coded as orthotopic when the artery originated from the descending aorta between the levels of the fifth and sixth thoracic vertebrae; all other bronchial arteries were considered ectopic. From the studied population, 137 (64%) patients had only orthotopic bronchial arteries, whereas 77 patients (36%) had at least one bronchial artery of ectopic origin. A total of 147 ectopic arteries were depicted, originating as common bronchial trunks (n = 23; 19%) or isolated right or left bronchial arteries (n = 101; 81%). The most frequent sites of origin of the 124 ostiums were the concavity of the aortic arch (92/124; 74%), the subclavian artery (13/124; 10.5%) and the descending aorta (10/124; 8.5%). The isolated ectopic bronchial arteries supplied the ipsilateral lung in all but three cases. Bronchial artery embolization was indicated in 26 patients. On the basis of CTA information, (1

  14. Evaluation of diagnostic and operative problems in basal meningioma by two-plane CT and angiography

    International Nuclear Information System (INIS)

    Inoue, Hiroshi; Tamura, Masaru; Kawafuchi, Jun-ichi

    1982-01-01

    Basal meningiomas were investigated using two-plane computed tomography (CT) with an ordinary section combined with a reverse section to ascertain the precise site of the origin, size, extension, properties and relation to adjacent tissue. Furthermore, with information obtained from angiography, operative difficulty and operative indications were investigated, to determine a therapeutic policy taking neurofunctional prognosis into consideration. The factors directly affecting the operative difficulty were the large size of the tumor, deformity of the hypothamus and brain stem, supratentorial or infratentorial extension, bone erosion, calcification of the tumor, direct effect on the major vessels and high vascularity. It is considered to be difficult or impossible to perform operations in cases accompanied by more than three of these factors and, in the case of posterior fossa tumors, more than two. Tumor density, extent of enhancement, perifocal low-density, ventricular dilatation, transtentorial herniation, brain or brain stem displacement, bone erosion on CT scans as well as tumor vascularity, feeding arteries, and changes in the major vessels on angiograms were also studied, and therapeutic problems as well as their countermeasures regarding these findings were discussed. It is emphasized that obtaining more accurate information concerning the preoperative state is the first step towards the improvement of therapeutic results in basal meningiomas. (author)

  15. Automated quantification of epicardial adipose tissue using CT angiography: evaluation of a prototype software

    Energy Technology Data Exchange (ETDEWEB)

    Spearman, James V.; Silverman, Justin R.; Krazinski, Aleksander W.; Costello, Philip [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Meinel, Felix G.; Geyer, Lucas L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Apfaltrer, Paul [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University Medical Center Mannheim, Medical Faculty Mannheim - Heidelberg University, Institute of Clinical Radiology and Nuclear Medicine, Mannheim (Germany); Canstein, Christian [Siemens Medical Solutions USA, Inc., Malvern, PA (United States); De Cecco, Carlo Nicola [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' - Polo Pontino, Department of Radiological Sciences, Oncology and Pathology, Latina (Italy)

    2014-02-15

    This study evaluated the performance of a novel automated software tool for epicardial fat volume (EFV) quantification compared to a standard manual technique at coronary CT angiography (cCTA). cCTA data sets of 70 patients (58.6 ± 12.9 years, 33 men) were retrospectively analysed using two different post-processing software applications. Observer 1 performed a manual single-plane pericardial border definition and EFV{sub M} segmentation (manual approach). Two observers used a software program with fully automated 3D pericardial border definition and EFV{sub A} calculation (automated approach). EFV and time required for measuring EFV (including software processing time and manual optimization time) for each method were recorded. Intraobserver and interobserver reliability was assessed on the prototype software measurements. T test, Spearman's rho, and Bland-Altman plots were used for statistical analysis. The final EFV{sub A} (with manual border optimization) was strongly correlated with the manual axial segmentation measurement (60.9 ± 33.2 mL vs. 65.8 ± 37.0 mL, rho = 0.970, P < 0.001). A mean of 3.9 ± 1.9 manual border edits were performed to optimize the automated process. The software prototype required significantly less time to perform the measurements (135.6 ± 24.6 s vs. 314.3 ± 76.3 s, P < 0.001) and showed high reliability (ICC > 0.9). Automated EFV{sub A} quantification is an accurate and time-saving method for quantification of EFV compared to established manual axial segmentation methods. (orig.)

  16. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity

    International Nuclear Information System (INIS)

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M.; Schlattmann, Peter; Dewey, Marc

    2013-01-01

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item (''Uninterpretable Results'') showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with ''no fulfilment'' increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. (orig.)

  17. Methodological quality of diagnostic accuracy studies on non-invasive coronary CT angiography: influence of QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) items on sensitivity and specificity

    Energy Technology Data Exchange (ETDEWEB)

    Schueler, Sabine; Walther, Stefan; Schuetz, Georg M. [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite Medical School, Department of Radiology, Berlin (Germany); Schlattmann, Peter [University Hospital of Friedrich Schiller University Jena, Department of Medical Statistics, Informatics, and Documentation, Jena (Germany); Dewey, Marc [Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Charite Medical School, Department of Radiology, Berlin (Germany); Charite, Institut fuer Radiologie, Berlin (Germany)

    2013-06-15

    To evaluate the methodological quality of diagnostic accuracy studies on coronary computed tomography (CT) angiography using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies included in systematic reviews) tool. Each QUADAS item was individually defined to adapt it to the special requirements of studies on coronary CT angiography. Two independent investigators analysed 118 studies using 12 QUADAS items. Meta-regression and pooled analyses were performed to identify possible effects of methodological quality items on estimates of diagnostic accuracy. The overall methodological quality of coronary CT studies was merely moderate. They fulfilled a median of 7.5 out of 12 items. Only 9 of the 118 studies fulfilled more than 75 % of possible QUADAS items. One QUADAS item (''Uninterpretable Results'') showed a significant influence (P = 0.02) on estimates of diagnostic accuracy with ''no fulfilment'' increasing specificity from 86 to 90 %. Furthermore, pooled analysis revealed that each QUADAS item that is not fulfilled has the potential to change estimates of diagnostic accuracy. The methodological quality of studies investigating the diagnostic accuracy of non-invasive coronary CT is only moderate and was found to affect the sensitivity and specificity. An improvement is highly desirable because good methodology is crucial for adequately assessing imaging technologies. (orig.)

  18. Adrenal pseudomasses due to varices: angiographic-CT-MRI-pathologic correlations

    International Nuclear Information System (INIS)

    Brady, T.M.; Gross, B.H.; Glazer, G.M.; Williams, D.M.

    1985-01-01

    Periadrenal and adrenal portosystemic collaterals are a recently reported cause of adrenal pseudotumor on computed tomography (CT). Nine patients with this left adrenal pseudotumor illustrate its typical position and appearance on CT, angiography, CT-angiography, and magnetic resonance imaging (MRI). The anatomic basis for variceal adrenal pseudotumors is the left inferior phrenic vein, which passes immediately anterior to the left adrenal gland and which serves as a collateral pathway from splenic to left renal vein in portal hypertension. Thus, unlike previously described adrenal pseudotumors, these venous collaterals are not anatomically distinguishable from the adrenal gland on CT. Bolus dynamic CT is usually diagnostic, but in equivocal cases, MRI may prove useful

  19. Adrenal pseudomasses due to varices: angiographic-CT-MRI-pathologic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Brady, T.M.; Gross, B.H.; Glazer, G.M. Williams, D.M.

    1985-08-01

    Periadrenal and adrenal portosystemic collaterals are a recently reported cause of adrenal pseudotumor on computed tomography (CT). Nine patients with this left adrenal pseudotumor illustrate its typical position and appearance on CT, angiography, CT-angiography, and magnetic resonance imaging (MRI). The anatomic basis for variceal adrenal pseudotumors is the left inferior phrenic vein, which passes immediately anterior to the left adrenal gland and which serves as a collateral pathway from splenic to left renal vein in portal hypertension. Thus, unlike previously described adrenal pseudotumors, these venous collaterals are not anatomically distinguishable from the adrenal gland on CT. Bolus dynamic CT is usually diagnostic, but in equivocal cases, MRI may prove useful.

  20. Coronary Computed Tomographic Angiography-Derived Fractional Flow Reserve for Therapeutic Decision Making.

    Science.gov (United States)

    Tesche, Christian; Vliegenthart, Rozemarijn; Duguay, Taylor M; De Cecco, Carlo N; Albrecht, Moritz H; De Santis, Domenico; Langenbach, Marcel C; Varga-Szemes, Akos; Jacobs, Brian E; Jochheim, David; Baquet, Moritz; Bayer, Richard R; Litwin, Sheldon E; Hoffmann, Ellen; Steinberg, Daniel H; Schoepf, U Joseph

    2017-12-15

    This study investigated the performance of coronary computed tomography angiography (cCTA) with cCTA-derived fractional flow reserve (CT-FFR) compared with invasive coronary angiography (ICA) with fractional flow reserve (FFR) for therapeutic decision making in patients with suspected coronary artery disease (CAD). Seventy-four patients (62 ± 11 years, 62% men) with at least 1 coronary stenosis of ≥50% on clinically indicated dual-source cCTA, who had subsequently undergone ICA with FFR measurement, were retrospectively evaluated. CT-FFR values were computed using an on-site machine-learning algorithm to assess the functional significance of CAD. The therapeutic strategy (optimal medical therapy alone vs revascularization) and the appropriate revascularization procedure (percutaneous coronary intervention vs coronary artery bypass grafting) were selected using cCTA-CT-FFR. Thirty-six patients (49%) had a functionally significant CAD based on ICA-FFR. cCTA-CT-FFR correctly identified a functionally significant CAD and the need of revascularization in 35 of 36 patients (97%). When revascularization was deemed indicated, the same revascularization procedure (32 percutaneous coronary interventions and 3 coronary artery bypass grafting) was chosen in 35 of 35 patients (100%). Overall, identical management strategies were selected in 73 of the 74 patients (99%). cCTA-CT-FFR shows excellent performance to identify patients with and without the need for revascularization and to select the appropriate revascularization strategy. cCTA-CT-FFR as a noninvasive "one-stop shop" has the potential to change diagnostic workflows and to directly inform therapeutic decision making in patients with suspected CAD. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Kuhlman, Taylor S.; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Duguay, Taylor M. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Department of Cardiology, Heart Centre Munich-Bogenhausen, Munich (Germany); Vogl, Thomas J. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt (Germany); Nikolaou, Konstantin [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2017-01-15

    Highlights: • TAVR-planning CT was performed with automated tube voltage selection. • Automated tube voltage selection enables individual tube voltage adaptation. • Image quality was diagnostic while radiation exposure was significantly decreased. - Abstract: Purpose: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.

  2. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure

    International Nuclear Information System (INIS)

    Mangold, Stefanie; De Cecco, Carlo N.; Schoepf, U. Joseph; Kuhlman, Taylor S.; Varga-Szemes, Akos; Caruso, Damiano; Duguay, Taylor M.; Tesche, Christian; Vogl, Thomas J.; Nikolaou, Konstantin

    2017-01-01

    Highlights: • TAVR-planning CT was performed with automated tube voltage selection. • Automated tube voltage selection enables individual tube voltage adaptation. • Image quality was diagnostic while radiation exposure was significantly decreased. - Abstract: Purpose: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.

  3. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    Science.gov (United States)

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  4. Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kai [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Li, Kuncheng, E-mail: cjr.likuncheng@vip.163.com [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Han, Ruijuan [Department of Cardiology, Chaoyang Hospital, Capital Medical University, Beijing 100020 (China); Li, Wenhuan; Chen, Nan; Yang, Qi; Du, Xiangying; Wang, Chen [Department of Radiology, Xuanwu Hospital, Capital Medical University, Beijing 100053 (China); Liu, Guorong; Li, Yuechun [Department of Neurology Baotou Central Hospital, Inner Mongolia, Baotou 014040 (China); Zhou, Maorong [Department of Radiology, Baotou Central Hospital, Inner Mongolia, Baotou 014040 (China); Li, Ligang; Heidrun, Endt [CT BM Clinic Marketing, Siemens Healthcare, Beijing 100102 (China)

    2015-03-15

    Objectives: To explore the feasibility and diagnostic accuracy of a combined one-step high-pitch dual-source computed tomography angiography (CTA) technique for evaluation of coronary and carotid-cerebrovascular arteries. Materials and methods: 85 symptomatic patients suspected of coronary artery and cerebrovascular disease referred for simultaneous coronary and carotid-cerebrovascular CTA were included. Additional invasive angiography of the coronary and cerebral arteries was performed within 30 days in 23 and 13 patients, respectively. The objective parameters of image quality, the mean CT attenuations, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. The subjective image quality of vessels was also assessed by 2 independent radiologists blinded to the patients’ medical history and scan protocols. The diagnostic performance of CTA including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the detection or exclusion of significant artery stenosis was calculated using the chi-squared test of contingency and correlated with the results of invasive angiography representing the standard of reference. Results: Image quality was rated excellent (score 1) in 95.3% (1074/1127), good (score 2) in 3.3% (37/1127), adequate (score 3) in 1.0% (11/1127), and non-diagnostic (score 4) in 0.4% (5/1127) of coronary segments. Image quality of carotid and cerebral vessels was rated mostly excellent (score 1, 95.12% [78/82]; score 2, 3.66% [3/82]; score 3, 1.22% [1/82]). The sensitivity, specificity, PPV and NPV for the detection of coronary stenosis were 92.2% (81.1–97.7%), 95.2% (91.7–97.5%), 79.6% (67.1–89.1%) and 98.3% (95.8–99.5%), respectively. For the detection of carotid and cerebral artery stenosis, CTA demonstrated a sensitivity of 92.8% (80.5–98.4%), a specificity of 93.5% (88.3–96.8%), a PPV of 79.6% (65.6–89.7%) and a NPV of 97.9% (94.1–99.5%). The effective

  5. CT angiography - head and neck

    Science.gov (United States)

    ... your provider if you take the diabetes medicine metformin (Glucophage). You may need to take extra precautions. ... to the kidneys from the dye CT scans use more radiation than regular x-rays. Having many ...

  6. Impact of new technologies on dose reduction in CT

    International Nuclear Information System (INIS)

    Lee, Ting-Yim; Chhem, Rethy K.

    2010-01-01

    The introduction of slip ring technology enables helical CT scanning in the late 1980's and has rejuvenated CT's role in diagnostic imaging. Helical CT scanning has made possible whole body scanning in a single breath hold and computed tomography angiography (CTA) which has replaced invasive catheter based angiography in many cases because of its easy of operation and lesser risk to patients. However, a series of recent articles and accidents have heightened the concern of radiation risk from CT scanning. Undoubtedly, the radiation dose from CT studies, in particular, CCTA studies, are among the highest dose studies in diagnostic imaging. Nevertheless, CT has remained the workhorse of diagnostic imaging in emergent and non-emergent situations because of their ubiquitous presence in medical facilities from large academic to small regional hospitals and their round the clock accessibility due to their ease of use for both staff and patients as compared to MR scanners. The legitimate concern of radiation dose has sparked discussions on the risk vs benefit of CT scanning. It is recognized that newer CT applications, like CCTA and perfusion, will be severely curtailed unless radiation dose is reduced. This paper discusses the various hardware and software techniques developed to reduce radiation dose to patients in CT scanning. The current average effective dose of a CT study is ∼10 mSv, with the implementation of dose reduction techniques discussed herein; it is realistic to expect that the average effective dose may be decreased by 2-3 fold.

  7. Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation.

    Science.gov (United States)

    Andreini, Daniele; Pontone, Gianluca; Mushtaq, Saima; Mancini, Maria Elisabetta; Conte, Edoardo; Guglielmo, Marco; Volpato, Valentina; Annoni, Andrea; Baggiano, Andrea; Formenti, Alberto; Ditali, Valentina; Perchinunno, Marco; Fiorentini, Cesare; Bartorelli, Antonio L; Pepi, Mauro

    2018-04-01

    To evaluate image quality, coronary evaluability and radiation exposure of coronary CT angiography (CCTA) performed with whole-heart coverage cardiac-CT in patients with atrial fibrillation (AF). We prospectively enrolled 164 patients with AF who underwent a clinically indicated CCTA with a 16-cm z-axis coverage scanner. In all patients CCTA was performed using prospective ECG-triggering with targeted RR interval. We evaluated image quality, coronary evaluability and effective dose (ED). Patients were divided in two subgroups based on heart rate (HR) during imaging. Group 1: 64 patients with low HR (ethics committee approved the study protocol. In a segment-based analysis, coronary evaluability was 98.4 % (2,577/2,620 segments) in the whole population, without significant differences between groups (1,013/1,024 (98.9 %) and 1,565/1,596 (98.1 %), for groups 1 and 2, respectively, p=0.15). Mean ED was similar in both groups (3.8±1.9 mSv and 3.9±2.1 mSv in groups 1 and 2, respectively, p=0.75) CONCLUSIONS: The whole-heart-coverage scanner could evaluate coronary arteries with high image quality and without increase in radiation exposure in AF patients, even in the high HR group. • Last-generation CT scanner improves coronary artery assessment in AF patients. • The new CT scanner enables low radiation exposure in AF patients. • Diagnostic ICA maybe avoided in AF patients with suspected CAD. • Whole-heart coverage CT scanner enables low radiation exposure in AF patients.

  8. Exacerbation of radiation induced meningioma due to hemorrhage after cerebral angiography. A case report

    International Nuclear Information System (INIS)

    Yamaguchi, Shinya; Matsuo, Yoshihiro; Uesaka, Toshio; Matsukado, Koichiro; Suzuki, Satoshi O.; Iwaki, Toru

    2011-01-01

    We report the case of a 34-year-old woman who exhibited acute deterioration in her condition after cerebral angiography for evaluation of a large meningioma. She had undergone surgery and irradiation for a glioma in the right occipital lobe 23 years before this episode. She experienced incapacity at work. On CT and MRI, a large meningioma was detected on the left frontal convexity; this tumor was thought to be radiation-induced. Cerebral angiography was performed to assess the vascularization of the tumor. Her condition began to deteriorate 2.5 h after the cerebral angiography. CT revealed an increase in the mass of the tumor, and a high density area in the tumor. We immediately removed the tumor. Histopathological examinationrevealed the tumor to be a meningothelial meningioma. New hemorrhagic foci were identified in the tumor. In addition, macrophages containing hemosiderin were detected, and some of the tumor vessels exhibited hyaline degeneration. We suspected that angiography triggered bleeding in the meningioma, which was already predisposed to hemorrhage. (author)

  9. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  10. CT findings as confirmatory criteria of brain death

    International Nuclear Information System (INIS)

    Shiogai, Toshiyuki; Takeuchi, Kazuo

    1983-01-01

    The absence of cerebral circulation and electrocerebral silence have served as an accurate index of irreversible brain death. It is proposed that computed tomography (CT) findings be evaluated as confirmatory criteria of brain death. To this end, CT evaluation of 14 patients satisfying the conventional criteria of brain death was performed. A CT finding of severe compression or dissappearance of the ventricular system, or so called ''brain tamponade'', was seen in 7 (50 %) of the 14 patients. Enhanced contrast CT, especially dynamic CT, usually distinctly reveals the cerebral vessels whenever the cerebral blood flow is preserved; conversely, the lack of enhanced brain structures, even comparing attenuation values, indicates the absence of cerebral blood flow. In 7 (70 %) of 10 patients, however, there was enhanced contrast of vascular brain structures, especially the circle of Willis, major cerebral arteries, choroid plexuses, and venous sinuses. It is suggested that this result is due to the improvement of demonstrability by CT. The usefulness of CT in the confirmation of brain death lies in visualization of the pathological changes associated with a dead brain, such as ''brain tamponade'', and the lack of enhanced contrast indicating the absence of cerebral blood flow. The latter point is still problematic as angiography revealed an extremely low cerebral blood flow in a few cases of ''dead brain'' patients. It is recommended that cerebral blood flow in brain death be evaluated by dynamic CT scanning and correlated with other methods of cerebral blood flow determination (e.g., intravenous digital subtraction angiography). (Author)

  11. CT findings as confirmatory criteria of brain death

    Energy Technology Data Exchange (ETDEWEB)

    Shiogai, Toshiyuki; Takeuchi, Kazuo (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine)

    1983-12-01

    The absence of cerebral circulation and electrocerebral silence have served as an accurate index of irreversible brain death. It is proposed that computed tomography (CT) findings be evaluated as confirmatory criteria of brain death. To this end, CT evaluation of 14 patients satisfying the conventional criteria of brain death was performed. A CT finding of severe compression or dissappearance of the ventricular system, or so called ''brain tamponade'', was seen in 7 (50 %) of the 14 patients. Enhanced contrast CT, especially dynamic CT, usually distinctly reveals the cerebral vessels whenever the cerebral blood flow is preserved; conversely, the lack of enhanced brain structures, even comparing attenuation values, indicates the absence of cerebral blood flow. In 7 (70 %) of 10 patients, however, there was enhanced contrast of vascular brain structures, especially the circle of Willis, major cerebral arteries, choroid plexuses, and venous sinuses. It is suggested that this result is due to the improvement of demonstrability by CT. The usefulness of CT in the confirmation of brain death lies in visualization of the pathological changes associated with a dead brain, such as ''brain tamponade'', and the lack of enhanced contrast indicating the absence of cerebral blood flow. The latter point is still problematic as angiography revealed an extremely low cerebral blood flow in a few cases of ''dead brain'' patients. It is recommended that cerebral blood flow in brain death be evaluated by dynamic CT scanning and correlated with other methods of cerebral blood flow determination (e.g., intravenous digital subtraction angiography).

  12. Diagnostic performance of CT and MRI on the detection of symptomatic intracranial dural arteriovenous fistula: a meta-analysis with indirect comparison

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yen-Heng [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China); Lin, Hsien-Ho [National Taiwan University, Institute of Epidemiology and Preventive Medicine, Taipei (China); Liu, Hon-Man; Lee, Chung-Wei; Chen, Ya-Fang [National Taiwan University Hospital in Taipei and Yuan-Lin Branch, Department of Medical Imaging and Radiology, Hospital and Medical College, Taipei (China)

    2016-08-15

    This study aims to review the diagnostic performance of computed tomography (CT) and magnetic resonance imaging (MRI) in symptomatic dural arteriovenous fistula (DAVF). EMBASE, PubMed, and Cochrane Library were searched until April 2015 for studies which compared CT, MRI, or both with angiography for the detection of DAVF. The diagnostic performances of MRI and CT were indirectly compared using modality as a covariate in the analysis. Thirteen studies met our inclusion criteria. MRI had a sensitivity of 0.90 (95 % confidence interval (CI) = 0.83-0.94) and specificity of 0.94 (95 % CI = 0.90-0.96). CT had a sensitivity of 0.80 (95 % CI = 0.62-0.90) and specificity of 0.87 (95 % CI = 0.74-0.94). MRI showed better diagnostic performance than CT (p = 0.02). Contrast medium use and time-resolved MR angiography did not improve MRI diagnostic performance (p = 0.31 and 0.44, respectively). Both CT and MRI had good diagnostic performance. MRI was better than CT on the detection of symptomatic intracranial dural arteriovenous fistula in the indirect comparison. (orig.)

  13. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  14. Intravenous spiral CT angiography for assessment before orthotopic liver transplantation: Comparison between tomography, MIP, 3-dimensional surface imaging and intraarterial DSA

    International Nuclear Information System (INIS)

    Hidajat, N.; Vogl, T.J.; Moeller, M.; Bechstein, W.O.; Felix, R.

    1996-01-01

    Purpose: To analyse the efficacy of intravenous spiral CT angiography (SCTA) for the evaluation before orthotopic liver transplantation (oLT) compared with DSA. Methods: Spiral CT was performed on 31 potential recipients of a liver graft in order to examine hepatic vessels, coeliac axis, splenic artery and superior mesenteric artery. The arterial vessels were reconstructed in 'Maximum Intensity Projection (MIP)' and 'Shaded Surface Display (SSD)'-technique. The axial images, MIP and SSD were compared in 25 patients with DSA with regard to the visualisation of the vascular anatomy, detectability of stenosis and vascular diameters. Results: The type of arterial liver supply could be determined via SCTA in all patients. Stenosis of the coeliac axis was seen in ten patients on the DSA, MIP and SSD and in eight patients on the axial images. Occlusion of the hepatic artery was clearly visualised in two patients on the DSA, axial images and MIP and in one patient on the SSD. There was no false positive diagnosis with SCTA. SSD was seen as the best technique to visualise the vessels without overshadowing. There were no significant differences between the diamters measured from the axial images, MIP and SSD images in transversal direction and the DSA images (p>0.05). Conclusion: SCTA is a greatly promising method for the imaging of vessels supplying the liver before oLT, and may convey more diagnostic information than DSA. (orig.) [de

  15. Metal artifact reduction for flat panel detector intravenous CT angiography in patients with intracranial metallic implants after endovascular and surgical treatment.

    Science.gov (United States)

    Pjontek, Rastislav; Önenköprülü, Belgin; Scholz, Bernhard; Kyriakou, Yiannis; Schubert, Gerrit A; Nikoubashman, Omid; Othman, Ahmed; Wiesmann, Martin; Brockmann, Marc A

    2016-08-01

    Flat panel detector CT angiography with intravenous contrast agent injection (IV CTA) allows high-resolution imaging of cerebrovascular structures. Artifacts caused by metallic implants like platinum coils or clips lead to degradation of image quality and are a significant problem. To evaluate the influence of a prototype metal artifact reduction (MAR) algorithm on image quality in patients with intracranial metallic implants. Flat panel detector CT after intravenous application of 80 mL contrast agent was performed with an angiography system (Artis zee; Siemens, Forchheim, Germany) using a 20 s rotation protocol (200° rotation angle, 20 s acquisition time, 496 projections). The data before and after MAR of 26 patients with a total of 34 implants (coils, clips, stents) were independently evaluated by two blinded neuroradiologists. MAR improved the assessability of the brain parenchyma and small vessels (diameter metallic implants and at a distance of 6 cm (p<0.001 each, Wilcoxon test). Furthermore, MAR significantly improved the assessability of parent vessel patency and potential aneurysm remnants (p<0.005 each, McNemar test). MAR, however, did not improve assessability of stented vessels. When an intravenous contrast protocol is used, MAR significantly ameliorates the assessability of brain parenchyma, vessels, and treated aneurysms in patients with intracranial coils or clips. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Step-and-shoot prospectively ECG-gated vs. retrospectively ECG-gated with tube current modulation coronary CT angiography using 128-slice MDCT patients with chest pain: diagnostic performance and radiation dose

    International Nuclear Information System (INIS)

    Kim, Jeong Su; Choo, Ki Seok; Jeong, Dong Wook

    2011-01-01

    Background With increasing awareness for radiation exposure, the study of diagnostic accuracy of coronary CT angiography (CCTA) with low radiation dose techniques is mandatory to both radiologist and clinician. Purpose To compare diagnostic performance and effective radiation dose between step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with tube current modulation (TCM) CCTA using 128-slice multidetector computed tomography (MDCT). Material and Methods We retrospectively evaluated 60 patients who underwent CCTA with either of two different low-dose techniques using 128-slice MDCT (23 patients for step-and shoot-prospectively ECG-gated and 37 patients for retrospectively ECG-gated with TCM CCTA) followed by conventional coronary angiography. All coronary arteries and all segments thereof, except anatomical variants or small size (< 1.5 mm) ones, were included in analysis. Results In per-segment analysis, sensitivity, specificity, positive predictive value, and negative predictive value were 91/96%, 95/94%, 75/73%, and 98/99% for step-and-shoot prospectively ECG-gated and retrospectively ECG gated with TCM CCTA, respectively, relative to conventional coronary angiography. Effective radiation dose were 1.75 ± 0.83 mSv, 4.91 ± 1.71 mSv in the step-and-shoot prospectively ECG-gated and retrospectively ECG-gated with TCM CCTA groups, respectively. Conclusion The two low-radiation dose CCTA techniques using 128-slice MDCT yields comparable diagnostic performance for coronary artery disease in symptomatic patients with low heart rates

  17. A contrast enhancement and scanning techniques for CT angiography of head and neck. One phase injection method for simultaneous imaging of vessels and tumor

    International Nuclear Information System (INIS)

    Morita, Yasuhiko; Indo, Hiroko; Noikura, Takenori

    1999-01-01

    We report on a method of CT-Angiography useful for examining lesion of the head and neck using three-dimensional images and measured CT value. This study focused on some of the important blood vessels in the head and neck. The aim of this method was to obtain high-contrast enhancement for both vessels and tumors at same time. A total amount of 100 ml nonionic contrast media (Omnipaque 240, 240 mg iodine per milliliter, Daiichi seiyaku, Tokyo, Japan) was injected intravenously with a flow of 1.5 ml/sec. Spiral scans, 24 rotations with 24 seconds, were started at a time when remaining amount of contrast media had become 30 to 20 ml. All CT scans were performed using double speed spiral scan technique with a slice thickness of 2 to 3 mm and table speeds from 3 to 5 mm/rotation. The patients populations consisted of 9 men and 6 women who ranged in age from 37 to 85 years. Sixteen CT-angiography were performed according to this method. Mean CT values of major blood vessels were measured in order to find out threshold at the level of submandibular gland in 13 examinations for 12 subjects. Important vessels like the common, internal, and the external artery, internal and external jugular vein were clearly visible in all subjects. Three dimensional images of these vessels could also be reconstructed for 15 of the subjects. Mean CT values were 211 Hounsfield units (HU) and 209 HU for the right and left internal carotid artery, respectively, and 204 HU and 206 HU for the right and left external carotid artery, respectively. Mean CT values for right and left internal jugular vein were 195 HU and 194 HU respectively. Measured CT values at each important blood vessels showed this method could yields acceptable enhancements. Good enhancement effect of tumor and blood vessels in the same scan seems to be mutually incompatible. One very important trade-off is the early enhancement effect at blood vessels versus the late enhancement effect at tumors. The other important trade

  18. Comparison of diagnostic accuracy of dual-source CT and conventional angiography in detecting congenital heart diseases

    International Nuclear Information System (INIS)

    Sedaghat, Fariborz; Pouraliakbar, Hamidreza; Motevalli, Marzieh; Karimi, Mohammad Ali; Armand, Sandbad

    2014-01-01

    Cardiac dual-source computed tomography (DSCT) is primarily used for coronary arteries. There are limited studies about the application of DSCT for congenital heart diseases. The aim of this study was to determine the diagnostic value of DSCT in the cardiac anomalies. The images of DSCTs and conventional angiographies of 36 patients (21 male; mean age: 8.5 month) with congenital heart diseases were reviewed and the parameters of diagnostic value of these methods were compared. Cardiac surgery was the gold standard. A total of 105 cardiac anomalies were diagnosed at surgery. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of DSCT were 98.25%, 97.9%, 98.1%, 99.07%, and 98.2%, respectively. The corresponding values of angiography were 95.04%, 98.7%, 97.8%, 98.1%, and 98%, respectively. Only one atrial septal defect (ASD) and two patent ductus arteriosus (PDA) were missed by DSCT. Angiography missed two ASD and two PDA. DSCT also provided important additional findings (n=35) about the intrathoracic or intraabdominal organs. DSCT is a highly accurate diagnostic modality for congenital heart diseases, obviating the need for invasive modalities. Beside its noninvasive nature, the advantage of DSCT over the angiography is its ability to provide detailed anatomical information about the heart, vessels, lungs and intraabdominal organs

  19. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  20. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    Science.gov (United States)

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.