  1. Cardiac CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Siripornpitak, Suvipaporn, E-mail: ssiripornpitak@yahoo.com [Division of Diagnostic Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok (Thailand); Pornkul, Ratanaporn [Division of Diagnostic Radiology, Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok (Thailand); Khowsathit, Pongsak [Pediatric Cardiac Unit, Department of Pediatrics, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok (Thailand); Layangool, Thanarat; Promphan, Worakan [Pediatric Cardiology Unit, Queen Sirikit National Institute of Child Health, Bangkok (Thailand); Pongpanich, Boonchob [Pediatric Cardiac Unit, Department of Pediatrics, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok (Thailand)

    2013-07-15

    Cardiac imaging plays an important role in both congenital and acquired heart diseases. Cardiac computed tomography (angiography) cCT(A) is a non-invasive, increasingly popular, complementary modality to echocardiography in evaluation of congenital heart diseases (CHD) in children. Despite radiation exposure, cCT(A) is now commonly used for evaluation of the complex CHD, giving information of both intra-cardiac and extra-cardiac anatomy, coronary arteries, and vascular structures. This review article will focus on the fundamentals and essentials for performing cCT(A) in children, including radiation dose awareness, basic techniques, and strengths and weaknesses of cCT(A) compared with cardiac magnetic resonance imaging (cMRI), and applications. The limitations of this modality will also be discussed, including the CHD for which cMRI may be substituted.

  2. CT coronary angiography versus conventional invasive coronary angiography. The view of the referring physician

    Energy Technology Data Exchange (ETDEWEB)

    Maurer, Martin H. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Universitaetsspital Bern (Switzerland). Dept. fuer Diagnostische, Interventionelle und Paediatrische Radiologie; Zimmermann, E.; Hamm, B. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiology; Dewey, M.

    2014-12-15

    Assessment of experience gained by local referring physicians with the procedure of coronary computed tomographic angiography (CCTA) in the everyday clinical routine. A 25-item questionnaire was sent to 179 physicians, who together had referred a total of 1986 patients for CCTA. They were asked about their experience to date with CCTA, the indications for coronary imaging, and their practice in referring patients for noninvasive CCTA or invasive catheter angiography. 53 questionnaires (30%) were assessable, corresponding to more than 72% of the patients referred. Of the referring physicians who responded, 94% saw a concrete advantage of CCTA in the treatment of patients, whereby 87% were 'satisfied' or 'very satisfied' with the reporting. For excluding coronary heart disease (CHD) where there was a low pre-test probability of disease, the physicians considered CCTA to be superior to conventional coronary diagnosis (4.2 on a scale of 1-5) and vice versa for acute coronary syndrome (1.6 of 5). The main reasons for unsuitability of CCTA for CT diagnosis were claustrophobia and the absence of a sinus rhythm. The level of exposure to radiation in CCTA was estimated correctly by only 42% of the referring physicians. 90% of the physicians reported that their patients evaluated their coronary CT overall as 'positive' or 'neutral', while 87% of the physicians whose patients had undergone both procedures reported that the patients had experienced CCTA as the less disagreeable of the two. CCTA is accepted by the referring physicians as an alternative imaging procedure for the exclusion of CHD and received a predominantly positive assessment from both the referring physicians and the patients.

  3. Incremental prognostic utility of coronary CT angiography for asymptomatic patients based upon extent and severity of coronary artery calcium: Results from the COronary CT Angiography EvaluatioN For Clinical Outcomes InteRnational Multicenter (CONFIRM) Study

    NARCIS (Netherlands)

    I. Cho (Iksung); H.-J. Chang (Hyuk-Jae); B.T. Hartaigh (Bríain ó); S. Shin (Sanghoon); J.M. Sung (Ji Min); F.Y. Lin (Fay); S. Achenbach (Stephan); R. Heo (Ran); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); T.Q. Callister (Tracy); M. Al-Mallah (Mouaz); F. Cademartiri (Filippo); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); A.M. Dunning (Allison M.); A. Delago (Augustin); T.C. Villines (Todd); M. Hadamitzky (Martin); J. Hausleiter (Jörg); J. Leipsic (Jonathon); L.J. Shaw (Leslee); P.A. Kaufmann (Philipp A.); R.C. Cury (Ricardo); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); E. Maffei (Erica); G.L. Raff (Gilbert); G. Pontone (Gianluca); D. Andreini (Daniele); J.K. Min (James K.)

    2015-01-01

    textabstractAim Prior evidence observed no predictive utility of coronary CT angiography (CCTA) over the coronary artery calcium score (CACS) and the Framingham risk score (FRS), among asymptomatic individuals. Whether the prognostic value of CCTA differs for asymptomatic patients, when stratified b

  4. Incremental prognostic utility of coronary CT angiography for asymptomatic patients based upon extent and severity of coronary artery calcium: Results from the COronary CT Angiography EvaluatioN For Clinical Outcomes InteRnational Multicenter (CONFIRM) Study

    NARCIS (Netherlands)

    I. Cho (Iksung); H.-J. Chang (Hyuk-Jae); B.T. Hartaigh (Bríain ó); S. Shin (Sanghoon); J.M. Sung (Ji Min); F.Y. Lin (Fay); S. Achenbach (Stephan); R. Heo (Ran); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); T.Q. Callister (Tracy); M. Al-Mallah (Mouaz); F. Cademartiri (Filippo); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); A.M. Dunning (Allison M.); A. Delago (Augustin); T.C. Villines (Todd); M. Hadamitzky (Martin); J. Hausleiter (Jörg); J. Leipsic (Jonathon); L.J. Shaw (Leslee); P.A. Kaufmann (Philipp A.); R.C. Cury (Ricardo); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); E. Maffei (Erica); G.L. Raff (Gilbert); G. Pontone (Gianluca); D. Andreini (Daniele); J.K. Min (James K.)

    2015-01-01

    textabstractAim Prior evidence observed no predictive utility of coronary CT angiography (CCTA) over the coronary artery calcium score (CACS) and the Framingham risk score (FRS), among asymptomatic individuals. Whether the prognostic value of CCTA differs for asymptomatic patients, when stratified b

  5. Diagnostic performance of coronary CT angiography for stenosis detection according to calcium score : systematic review and meta-analysis

    NARCIS (Netherlands)

    den Dekker, Martijn; de Smet, K.; de Bock, G.H.; Tio, R.A.; Oudkerk, M.; Vliegenthart, R.

    2012-01-01

    Objectives A systematic review and meta-analysis to assess sensitivity and specificity of coronary CT angiography (CCTA) for significant stenosis at different degrees of coronary calcification. Methods A literature search was performed including studies describing test characteristics of CCTA for

  6. Diagnostic Performance of First-Pass Myocardial Perfusion Imaging without Stress with Computed Tomography (CT) Compared with Coronary CT Angiography Alone, with Fractional Flow Reserve as the Reference Standard.

    Science.gov (United States)

    Osawa, Kazuhiro; Miyoshi, Toru; Miki, Takashi; Koyama, Yasushi; Sato, Shuhei; Kanazawa, Susumu; Ito, Hiroshi

    2016-01-01

    Coronary computed tomography angiography (CCTA) in combination with first-pass CT myocardial perfusion imaging (MPI) has a better diagnostic performance than CCTA alone, compared with invasive coronary angiography as the reference standard. The aim of this study was to investigate the additional diagnostic value of first-pass CT-MPI without stress for detecting hemodynamic significance of coronary stenosis, compared with invasive fractional flow reserve (FFR). We recruited 53 patients with suspected coronary artery disease undergoing both CCTA and first-pass CT-MPI without stress and invasive FFR, and 75 vessels were analyzed. We used the same raw data for CCTA and CT-MPI. First-pass CT-MPI was reconstructed by examining the diastolic signal densities as a bull's eye map. Invasive FFR CT-MPI and CCTA alone was 0.81 (0.73-0.90) and 0.70 (0.61-0.81), respectively (P = 0.036). CCTA plus first-pass CT-MPI without stress showed 0.73 sensitivity, 0.74 specificity, 0.53 positive predictive value, and 0.87 negative predictive value for detecting hemodynamically significant coronary stenosis. First-pass CT-MPI without stress correctly reclassified 38% of CCTA false-positive vessels as true negative. First-pass CT-MPI without stress combined with CCTA demonstrated excellent diagnostic accuracy, compared with invasive FFR as the reference standard. This technique could complement CCTA for diagnosis of coronary artery disease.

  7. Automatic coronary calcium scoring in cardiac CT angiography using convolutional neural networks

    NARCIS (Netherlands)

    Wolterink, Jelmer M.; Leiner, Tim; Viergever, Max A.; Isgum, I

    2015-01-01

    The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular events. Non-contrast enhanced cardiac CT is considered a reference for quantification of CAC. Recently, it has been shown that CAC may be quantified in cardiac CT angiography (CCTA). We present

  8. Diagnostic performance of coronary CT angiography for stenosis detection according to calcium score: systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dekker, Martijn A.M. den; Oudkerk, Matthijs; Vliegenthart, Rozemarijn [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Radiology, Hanzeplein 1, P.O. Box 30001, Groningen (Netherlands); Smet, Kristof de [University of Brussels, Department of Radiology, Brussels (Belgium); Bock, Geertruida H. de [University of Groningen, University Medical Center Groningen, Center for Medical Imaging - North East Netherlands, Department of Epidemiology, Groningen (Netherlands); Tio, Rene A. [University of Groningen, University Medical Center Groningen, Department of Cardiology, Groningen (Netherlands)

    2012-12-15

    A systematic review and meta-analysis to assess sensitivity and specificity of coronary CT angiography (CCTA) for significant stenosis at different degrees of coronary calcification. A literature search was performed including studies describing test characteristics of CCTA for significant stenosis, performed with at least 16-MDCT and according to calcium score (CS). Invasive coronary angiography was the reference standard. Pooled sensitivity and specificity of CCTA by CS categories and CT equipment were calculated. Of 14,121 articles, 51 studies reported on the impact of calcium scoring on diagnostic performance of CCTA and could be included in the systematic review. Twenty-seven of these studies (5,203 participants) were suitable for meta-analysis. On a patient-basis, sensitivity of CCTA for significant stenosis was 95.8, 95.6, 97.6 and 99.0% for CS 0-100, 101-400, 401-1,000 and >1,000 respectively. Specificity was 91.2, 88.2, 50.6 and 84.0% respectively. Specificity of CCTA was significantly lower for CS 401-1,000 due to lack of patients without significant stenosis. Sensitivity and specificity of 16-MDCT were significantly lower compared to more modern CT systems. Even in cases of severe coronary calcification, sensitivity and specificity of CCTA for significant stenosis are high. With 64-MDCT and newer CT systems, a CS cut-off for performing CCTA no longer seems indicated. (orig.)

  9. Current trends in patients with chronic total occlusions undergoing coronary CT angiography

    NARCIS (Netherlands)

    M.P. Opolski (Maksymilian P.); B.T. Hartaigh (Bríain ó); D.S. Berman (Daniel S.); M.J. Budoff (Matthew J.); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); J.K. Min (James)

    2015-01-01

    textabstractObjective: Data describing the prevalence, characteristics and management of coronary chronic total occlusions (CTOs) in patients undergoing coronary CT angiography (CCTA) have not been reported. The purpose of this study was to determine the prevalence, characteristics and treatment str

  10. Current trends in patients with chronic total occlusions undergoing coronary CT angiography

    NARCIS (Netherlands)

    M.P. Opolski (Maksymilian P.); B.T. Hartaigh (Bríain ó); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee J.); T.C. Villines (Todd); J.K. Min (James)

    2015-01-01

    textabstractObjective Data describing the prevalence, characteristics and management of coronary chronic total occlusions (CTOs) in patients undergoing coronary CT angiography (CCTA) have not been reported. The purpose of this study was to determine the prevalence, characteristics and treatment stra

  11. Current trends in patients with chronic total occlusions undergoing coronary CT angiography

    NARCIS (Netherlands)

    M.P. Opolski (Maksymilian P.); B.T. Hartaigh (Bríain ó); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee J.); T.C. Villines (Todd); J.K. Min (James)

    2015-01-01

    textabstractObjective Data describing the prevalence, characteristics and management of coronary chronic total occlusions (CTOs) in patients undergoing coronary CT angiography (CCTA) have not been reported. The purpose of this study was to determine the prevalence, characteristics and treatment stra

  12. Current trends in patients with chronic total occlusions undergoing coronary CT angiography

    NARCIS (Netherlands)

    M.P. Opolski (Maksymilian P.); B.T. Hartaigh (Bríain ó); D.S. Berman (Daniel S.); M.J. Budoff (Matthew J.); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); J.K. Min (James)

    2015-01-01

    textabstractObjective: Data describing the prevalence, characteristics and management of coronary chronic total occlusions (CTOs) in patients undergoing coronary CT angiography (CCTA) have not been reported. The purpose of this study was to determine the prevalence, characteristics and treatment str

  13. Coexistent coronary artery disease or myocardial bridging in patients with hypertrophic cardiomyopathy using coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hwan; Chun, Eun Ju; Kim, Yeo Koon; Yoo, Jin Young; Choi, Sang Il; Choi, Dong Ju [Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-07-15

    To evaluate the prevalence of coexistent coronary artery disease (CAD) or myocardial bridging (MB) in patients with hypertrophic cardiomyopathy (HCM) using coronary CT angiography (CCTA) and assess the role of CCTA. The prevalence of obstructive CAD (> 50% luminal reduction) and MB (partial and full encasement) were assessed in 150 patients with HCM diagnosed by clinical findings, electrocardiography, and echocardiography of 19588 consecutive patients who underwent CCTA for suspected CAD. The overall feasibility of coronary artery visualization was 98.9% with CCTA. In patients with HCM, the prevalence of obstructive CAD and MB (14.7% partial and 28.0% full encasement) were 23.3% and 42.7%, respectively. Age, hypertension, family history of premature CAD, Framingham risk score and severe chest pain were associated with CAD, whereas male gender and septal type were associated with MB (all p < 0.05). In comparison to invasive coronary angiography (n = 37), the diagnostic accuracy of CCTA for the detection of CAD and full encasement MB was 89.2% and 86.5%, respectively. One-quarter of patients with HCM had coexistent obstructive CAD or full encasement MB. CCTA can be a feasible and accurate noninvasive imaging modality for the detection of CAD and MB in patients with HCM.

  14. CT angiography and CT perfusion in acute ischemic stroke

    NARCIS (Netherlands)

    Seeters, T. van

    2016-01-01

    CT angiography and CT perfusion are used in patients with acute ischemic stroke for diagnostic purposes and to select patients for treatment. In this thesis, the reproducibility of CT angiography and CT perfusion is examined, the additional value of CT angiography and CT perfusion for stroke outcome

  15. Image Quality in Reduced-Dose Coronary CT Angiography

    NARCIS (Netherlands)

    Gagarina, Nina V.; Irwan, Roy; Gordina, Galina; Fominykh, Ekaterina; Sijens, Paul E.

    2011-01-01

    Rationale and Objectives: Concerns for patient's risk of radiation-induced cancer have increased demand for reduced-dose coronary computed tomography angiography (CCTA). Previous comparisons of full and reduced-dose CCTA were not conclusive, because results were compared in different groups of patie

  16. A practical approach for a patient-tailored dose protocol in coronary CT angiography using prospective ECG triggering

    NARCIS (Netherlands)

    Dijk, van J.D.; Huizing, E.D.; Jager, P.L.; Ottervanger, J.P.; Knollema, S.; Slump, C.H.; Dalen, van J.A.

    2015-01-01

    To derive and validate a practical patient-specific dose protocol to obtain an image quality, expressed by the image noise, independent of patients’ size and a better radiation dose justification in coronary CT angiography (CCTA) using prospective ECG triggering. 43 patients underwent clinically ind

  17. Coronary CT angiography for acute chest pain triage: Techniques for radiation exposure reduction; 128 vs. 64 multidetector CT

    Energy Technology Data Exchange (ETDEWEB)

    Goitein, Orly; Eshet, Yael; Konen, Eli (Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, and the Sackler Faculty of Medicine, Tel Aviv Univ., Tel Aviv (Israel)), email: orly.goitein@sheba.health.gov.il; Matetzky, Shlomi (Heart Inst., Sheba Medical Center, Tel Hashomer, and the Sackler Faculty of Medicine, Tel Aviv Univ., Tel Aviv (Israel)); Goitein, David (Surgery C, Sheba Medical Center, Tel Hashomer, and the Sackler Faculty of Medicine, Tel Aviv Univ., Tel Aviv (Israel)); Hamdan, Ashraf; Di Segni, Elio (Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, and the Sackler Faculty of Medicine, Tel Aviv Univ., Tel Aviv (Israel); Heart Inst., Sheba Medical Center, Tel Hashomer, and the Sackler Faculty of Medicine, Tel Aviv Univ., Tel Aviv (Israel))

    2011-10-15

    Background. Coronary CT angiography (CCTA) is used daily in acute chest pain triage, although exposing patients to significant radiation dosage. CCTA using prospective ECG gating (PG CCTA) enables significant radiation reduction Purpose. To determine whether the routine use of 128 vs. 64 multidetector CT (MDCT) can increase the proportion of patients scanned using PG CCTA technique, lowering radiation exposure, without decreasing image quality. Material and Methods. The study comprised 232 patients, 116 consecutive patients scanned using 128 MDCT (mean age 49 years, 79 men, BMI 28) and 116 consecutive patients (mean age 50 years, 75 men, BMI 28) which were scanned using 64 MDCT. PG CCTA was performed whenever technically permissible by each type of scanner: 64 MDCT = stable heart rate (HR) <60/min and weight <110 kg; 128 MDCT = stable HR < 70/min and weight <140 kg. All coronary segments were evaluated for image quality using a visual scale of 1-5. An estimated radiation dose was recorded. Results. PC CCTA was performed in 84% and 49% of the 128 and 64 MDCT groups, respectively (P < 0.0001). Average image quality score were 4.6 +- 0.3 and 4.7 +- 0.1 for the 128 and 64 MDCT, respectively (P = 0.08). The mean radiation dose exposure was 6.2 +- 4.8 mSv and 10.4 +- 7.5 mSv for the 128 and 64 MDCT, respectively (P = 0.008). Conclusion. The 128 MDCT scanner enables utilization of PG CCTA technique in a greater proportion of patients, thereby decreasing the related radiation significantly, without hampering image quality

  18. Coronary CT Angiography in Heavily Calcified Coronary Arteries: Improvement of Coronary Lumen Visualization and Coronary Stenosis Assessment With Image Postprocessing Methods

    Science.gov (United States)

    Sun, Zhonghua; Ng, Curtise K.C.; Xu, Lei; Fan, Zhanming; Lei, Jing

    2015-01-01

    Abstract To compare the diagnostic value of coronary CT angiography (CCTA) with use of 2 image postprocessing methods (CCTA_S) and (CCTA_OS) and original data (CCTA_O) for the assessment of heavily calcified plaques. Fifty patients (41 men, 9 women; mean age 61.9 years ± 9.1) with suspected coronary artery disease who underwent CCTA and invasive coronary angiography (ICA) examinations were included in the study. Image data were postprocessed with “sharpen” and smooth reconstruction algorithms in comparison with the original data without undergoing any image postprocessing to determine the effects on suppressing blooming artifacts due to heavy calcification in the coronary arteries. Minimal lumen diameter and degree of stenosis were measured and compared between CCTA_S, CCTA_OS, and CCTA_O with ICA as the reference method. The area under the curve (AUC) by receiver-operating characteristic curve analysis (ROC) was also compared among these 3 CCTA techniques. On a per-vessel assessment, the sensitivity, specificity, positive predictive value and negative predictive value, and 95% confidence interval (CI) were 100% (95% CI: 89%, 100%), 33% (95% CI: 22%, 45%), 41% (95% CI: 30%, 53%), 100% (95% CI: 85%, 100%) for CCTA_O, 94% (95% CI: 79%, 99%), 66% (95% CI: 54%, 77%), 57% (95% CI: 43%, 70%), and 95% (95% CI: 85%, 99%) for CCTA_S, 94% (95% CI: 79%, 99%), 44% (95% CI: 32%, 57%), 44% (95% CI: 32%, 57%), and 97% (95% CI: 79%, 99%) for CCTA_OS, respectively. The AUC by ROC curve analysis for CCTA_S showed significant improvement for detection of >50% coronary stenosis in left anterior descending coronary artery compared to that of CCTA_OS and CCTA_O methods (P coronary stenosis in the left circumflex and right coronary arteries (P > 0.05). CCTA with “sharpen” reconstruction reduces blooming artifacts from heavy calcification, thus, leading to significant improvement of specificity and positive predictive value of CCTA in patients with heavily calcified

  19. Noninvasive detection of coronary vasospastic angina using a double-acquisition coronary CT angiography protocol in the presence and absence of an intravenous nitrate: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun-Ju; Kim, Dong Won; Yoon, Seong Kuk; Lee, Ki-Nam [Dong-A University, Department of Radiology, College of Medicine, Busan (Korea, Republic of); Kim, Moo Hyun; Jin, Cai De [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Dong-A University Hospital, Global Clinical Trial Center, Busan (Korea, Republic of); Seo, Jeongmin; Park, Tae-Ho [Dong-A University, Department of Cardiology, College of Medicine, Busan (Korea, Republic of); Choi, Sang Il [Seoul National University Bundang Hospital, Department of Radiology, Seongnam-si (Korea, Republic of); Yoon, Yeonyee Elizabeth [Seoul National University Bundang Hospital, Department of Cardiology, Seongnam-si (Korea, Republic of)

    2017-03-15

    To evaluate the feasibility of a double-acquisition coronary CT angiography (CCTA) protocol in the presence and absence of an intravenous (IV) vasodilator infusion for detecting vasospastic angina. Twenty patients with a high clinical probability of vasospastic angina were enrolled. All subjects underwent baseline CCTA without a vasodilator in the early morning followed by a catheterized coronary angiography with ergonovine provocation test. Within 3 days, all subjects underwent repeat CCTA during a continuous IV infusion of nitrate. Vasospastic angina as detected by CCTA was defined as significant stenosis (≥50 %) with negative remodelling without definite plaques or diffuse small diameter (<2 mm) of a major coronary artery with a beaded appearance on baseline CT that completely dilated on IV nitrate CT. The CCTA results were compared to the catheterized ergonovine provocation test as the reference standard. Among 20 patients, the catheterized ergonovine provocation test detected vasospasm in 15 patients. The sensitivity, specificity, positive predictive value and negative predictive value of CCTA in a per-patient-based analysis were 73, 100, 100 and 56 %, respectively. Double-acquisition CCTA in the presence and absence of IV infusion of nitrate allows noninvasive detection of vasospastic angina with moderate sensitivity and high specificity. (orig.)

  20. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Yamasaki, Yuzo; Kamitani, Takeshi; Sagiyama, Koji; Yamanouchi, Torahiko; Honda, Hiroshi [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences, 3-1-1 Maidashi, Higashi-ku, Fukuoka (Japan); Nagao, Michinobu; Kawanami, Satoshi [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences, Fukuoka (Japan); Sakamoto, Ichiro [Kyushu University, Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Fukuoka (Japan); Yamamura, Kenichiro [Kyushu University, Department of Pediatrics, Graduate School of Medical Sciences, Fukuoka (Japan); Yabuuchi, Hidetake [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences, Fukuoka (Japan)

    2017-02-15

    To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements. Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test. Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size. 256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively. (orig.)

  1. CT Angiography (CTA)

    Science.gov (United States)

    ... during the procedure. Metal objects, including jewelry, eyeglasses, dentures and hairpins, may affect the CT images and ... of the procedure, you may be asked to complete a questionnaire to ensure your safety during this ...

  2. Technical feasibility and validation of a coronary artery calcium scoring system using CT coronary angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Pavitt, Christopher W. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Harron, Katie [Institute of Child Health, UCL, Centre for Paediatric Epidemiology and Biostatistics, London (United Kingdom); Lindsay, Alistair C.; Ray, Robin [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Zielke, Sayeh; Rubens, Michael B. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Gordon, Daniel [Royal Marsden Hospital, Department of Physics, London (United Kingdom); Padley, Simon P. [Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom); Nicol, Edward D. [Royal Brompton Hospital, Department of Cardiology, London (United Kingdom); Royal Brompton Hospital, Department of Radiology, London (United Kingdom); Imperial College, Faculty of Medicine, London (United Kingdom)

    2016-05-15

    We validate a novel CT coronary angiography (CCTA) coronary calcium scoring system. Calcium was quantified on CCTA images using a new patient-specific attenuation threshold: mean + 2SD of intra-coronary contrast density (HU). Using 335 patient data sets a conversion factor (CF) for predicting CACS from CCTA scores (CCTAS) was derived and validated in a separate cohort (n = 168). Bland-Altman analysis and weighted kappa for MESA centiles and Agatston risk groupings were calculated. Multivariable linear regression yielded a CF: CACS = (1.185 x CCTAS) + (0.002 x CCTAS x attenuation threshold). When applied to CCTA data sets there was excellent correlation (r = 0.95; p < 0.0001) and agreement (mean difference -10.4 [95 % limits of agreement -258.9 to 238.1]) with traditional calcium scores. Agreement was better for calcium scores below 500; however, MESA percentile agreement was better for high risk patients. Risk stratification was excellent (Agatston groups k = 0.88 and MESA centiles k = 0.91). Eliminating the dedicated CACS scan decreased patient radiation exposure by approximately one-third. CCTA calcium scores can accurately predict CACS using a simple, individualized, semiautomated approach reducing acquisition time and radiation exposure when evaluating patients for CAD. This method is not affected by the ROI location, imaging protocol, or tube voltage strengthening its clinical applicability. (orig.)

  3. Correlation between coronary computed tomographic angiography and fractional flow reserve

    DEFF Research Database (Denmark)

    Kristensen, Thomas Skaarup; Engstrøm, Thomas; Kelbæk, Henning

    2010-01-01

    Coronary CT angiography (CCTA) has become an important modality to evaluate the presence of coronary artery disease. Coronary artery stenosis of intermediate severity remains a therapeutic dilemma. Measurement of fractional flow reserve (FFR) during coronary angiography is the most established...... technique to determine the hemodynamic severity of a coronary artery lesion. The aim of this study was to compare CCTA with FFR....

  4. Incremental prognostic utility of coronary CT angiography for asymptomatic patients based upon extent and severity of coronary artery calcium: results from the COronary CT Angiography EvaluatioN For Clinical Outcomes InteRnational Multicenter (CONFIRM) Study

    Science.gov (United States)

    Cho, Iksung; Chang, Hyuk-Jae; Ó Hartaigh, Bríain; Shin, Sanghoon; Sung, Ji Min; Lin, Fay Y.; Achenbach, Stephan; Heo, Ran; Berman, Daniel S.; Budoff, Matthew J.; Callister, Tracy Q.; Al-Mallah, Mouaz H.; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; Dunning, Allison M.; DeLago, Augustin; Villines, Todd C.; Hadamitzky, Martin; Hausleiter, Joerg; Leipsic, Jonathon; Shaw, Leslee J.; Kaufmann, Philipp A.; Cury, Ricardo C.; Feuchtner, Gudrun; Kim, Yong-Jin; Maffei, Erica; Raff, Gilbert; Pontone, Gianluca; Andreini, Daniele; Min, James K.

    2015-01-01

    Aim Prior evidence observed no predictive utility of coronary CT angiography (CCTA) over the coronary artery calcium score (CACS) and the Framingham risk score (FRS), among asymptomatic individuals. Whether the prognostic value of CCTA differs for asymptomatic patients, when stratified by CACS severity, remains unknown. Methods and results From a 12-centre, 6-country observational registry, 3217 asymptomatic individuals without known coronary artery disease (CAD) underwent CACS and CCTA. Individuals were categorized by CACS as: 0–10, 11–100, 101–400, 401–1000, >1000. For CCTA analysis, the number of obstructive vessels—as defined by the per-patient presence of a ≥50% luminal stenosis—was used to grade the extent and severity of CAD. The incremental prognostic value of CCTA over and above FRS was measured by the likelihood ratio (LR) χ2, C-statistic, and continuous net reclassification improvement (NRI) for prediction, discrimination, and reclassification of all-cause mortality and non-fatal myocardial infarction. During a median follow-up of 24 months (25th–75th percentile, 17–30 months), there were 58 composite end-points. The incremental value of CCTA over FRS was demonstrated in individuals with CACS >100 (LRχ2, 25.34; increment in C-statistic, 0.24; NRI, 0.62, all P 0.05). For subgroups with CACS >100, the utility of CCTA for predicting the study end-point was evident among individuals whose CACS ranged from 101 to 400; the observed predictive benefit attenuated with increasing CACS. Conclusion Coronary CT angiography provides incremental prognostic utility for prediction of mortality and non-fatal myocardial infarction for asymptomatic individuals with moderately high CACS, but not for lower or higher CACS. PMID:25205531

  5. Influence of observer experience and training on proficiency in coronary CT angiography interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Herzog, Christopher [Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425 (United States); Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Radiologie München, Burgstraße 7, 80331 Munich (Germany); Kerl, J. Matthias [Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425 (United States); Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); De Rosa, Salvatore [Department of Cardiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Tekin, Tuna [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Boehme, Eike [Department of Cardiology, Bayerwaldklinik, Cham, Klinikstraße 22, 93413 Cham (Germany); Liem, Sven [Kardiologie am Rotkreuzplatz, Volkartstr. 5, 80634 Munich (Germany); Scheuchenzuber, Miriam [Radiologie München, Burgstraße 7, 80331 Munich (Germany); Kim, He-Ri [Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Bauer, Ralf W. [Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425 (United States); Department of Diagnostic and Interventional Radiology, Johann Wolfgang Goethe-University, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Silverman, Justin R. [Department of Radiology and Radiological Science, Medical University of South Carolina, 25 Courtenay Drive, Charleston, SC 29425 (United States); and others

    2013-08-15

    Purpose: To assess the influence of experience and training on the proficiency in coronary CT angiography (CCTA) interpretation of practitioners with different levels of experience. Methods and materials: Nine radiologist and cardiologist observers with varying prior CCTA experience ranging from novice to expert independently analyzed two case series of 50 catheter-correlated CCTA studies for coronary artery stenosis (0%, ≤49%, 50–74%, 75–99%, or 100%). Results of the first case series were unblinded and presented along with catheter angiography results to each reader before proceeding to the second series. Diagnostic accuracy on a per-segment basis was compared for all readers and both case series, respectively. Results: Correlation coefficients between CCTA and catheter angiography initially ranged between good (r = 0.87) and poor (r = 0.26), depending on reader experience, and significantly (p < 0.05) improved in the second case series (range: r = 0.42 to r = 0.91). Diagnostic accuracy was significantly (p < 0.05) higher for more experienced readers (range: 96.5–97.8%) as compared to less experienced observers (range: 90.7–93.6%). After completion of the second case series for less experienced readers sensitivity and PPV significantly (p < 0.05) improved (range: 62.7–67.8%/51.4–84.1%), but still remained significantly (p < 0.05) lower as compared to more experienced observers (range: 89.8–93.3%/80.6–93.3%). Conclusion: The level of experience appears to be a strong determinant of proficiency in CCTA interpretation. Limited one-time training improves proficiency in novice readers, but not to clinically satisfactory levels.

  6. Cardiac CT angiography for device surveillance after endovascular left atrial appendage closure.

    Science.gov (United States)

    Saw, Jacqueline; Fahmy, Peter; DeJong, Peggy; Lempereur, Mathieu; Spencer, Ryan; Tsang, Michael; Gin, Kenneth; Jue, John; Mayo, John; McLaughlin, Patrick; Nicolaou, Savvas

    2015-11-01

    Left atrial appendage (LAA) device imaging after endovascular closure is important to assess for device thrombus, residual leak, positioning, surrounding structures, and pericardial effusion. Cardiac CT angiography (CCTA) is well suited to assess these non-invasively. We report our consecutive series of non-valvular atrial fibrillation patients who underwent CCTA post-LAA closure with Amplatzer Cardiac Plug (ACP), Amulet (second generation ACP), or WATCHMAN devices. Patients underwent CCTA typically 1-6 months post-implantation. Prospective cardiac-gated CCTA was performed with Toshiba 320-detector or Siemens 2nd generation 128-slice dual-source scanners, and images interpreted with VitreaWorkstation™. GFR Amulet, 18 WATCHMAN). Average age was 75.5 ± 8.9 years, mean CHADS2 score 3.1 ± 1.3, and CHADS-VASc score 4.9 ± 1.6. All had contraindications to oral anticoagulation. Post-procedure, 41 (91.1%) were discharged on DAPT. There was one device embolization (ACP, successfully retrieved percutaneously) and one thrombus (WATCHMAN, resolved with 3 months of warfarin). There were two pericardial effusions, both pre-existing and not requiring intervention. Residual leak (patency) was seen in 28/44 (63.6%), and the mechanisms of leak were readily identified by CCTA (off-axis device, gaps at orifice, or fabric leak). Mean follow-up was 1.2 ± 1.1year, with no death, stroke, or systemic embolism. CCTA appears to be a feasible alternative to transoesophageal echocardiography for post-LAA device surveillance to evaluate for device thrombus, residual leak, embolization, position, and pericardial effusion. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  7. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  8. Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque - a comparison with histology

    Energy Technology Data Exchange (ETDEWEB)

    Puchner, Stefan B. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-Guided Therapy, Vienna (Austria); Ferencik, Maros [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Harvard Medical School, Division of Cardiology, Massachusetts General Hospital, Boston, MA (United States); Maurovich-Horvat, Pal [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Semmelweis University, MTA-SE Lenduelet Cardiovascular Imaging Research Group, Heart and Vascular Center, Budapest (Hungary); Nakano, Masataka; Otsuka, Fumiyuki; Virmani, Renu [CV Path Institute Inc., Gaithersburg, MD (United States); Kauczor, Hans-Ulrich [University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Hoffmann, Udo [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); Schlett, Christopher L. [Massachusetts General Hospital, Harvard Medical School, Cardiac MR PET CT Program, Department of Radiology, Boston, MA (United States); University Hospital Heidelberg, Ruprecht-Karls-University of Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany)

    2015-01-15

    To evaluate whether iterative reconstruction algorithms improve the diagnostic accuracy of coronary CT angiography (CCTA) for detection of lipid-core plaque (LCP) compared to histology. CCTA and histological data were acquired from three ex vivo hearts. CCTA images were reconstructed using filtered back projection (FBP), adaptive-statistical (ASIR) and model-based (MBIR) iterative algorithms. Vessel cross-sections were co-registered between FBP/ASIR/MBIR and histology. Plaque area <60 HU was semiautomatically quantified in CCTA. LCP was defined by histology as fibroatheroma with a large lipid/necrotic core. Area under the curve (AUC) was derived from logistic regression analysis as a measure of diagnostic accuracy. Overall, 173 CCTA triplets (FBP/ASIR/MBIR) were co-registered with histology. LCP was present in 26 cross-sections. Average measured plaque area <60 HU was significantly larger in LCP compared to non-LCP cross-sections (mm{sup 2}: 5.78 ± 2.29 vs. 3.39 ± 1.68 FBP; 5.92 ± 1.87 vs. 3.43 ± 1.62 ASIR; 6.40 ± 1.55 vs. 3.49 ± 1.50 MBIR; all p < 0.0001). AUC for detecting LCP was 0.803/0.850/0.903 for FBP/ASIR/MBIR and was significantly higher for MBIR compared to FBP (p = 0.01). MBIR increased sensitivity for detection of LCP by CCTA. Plaque area <60 HU in CCTA was associated with LCP in histology regardless of the reconstruction algorithm. However, MBIR demonstrated higher accuracy for detecting LCP, which may improve vulnerable plaque detection by CCTA. (orig.)

  9. Long-term prognostic impact of CT-Leaman score in patients with non-obstructive CAD: Results from the COronary CT Angiography EvaluatioN For Clinical Outcomes InteRnational Multicenter (CONFIRM) study.

    Science.gov (United States)

    Andreini, Daniele; Pontone, Gianluca; Mushtaq, Saima; Gransar, Heidi; Conte, Edoardo; Bartorelli, Antonio L; Pepi, Mauro; Opolski, Maksymilian P; Ó Hartaigh, Bríain; Berman, Daniel S; Budoff, Matthew J; Achenbach, Stephan; Al-Mallah, Mouaz; Cademartiri, Filippo; Callister, Tracy Q; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J W; Cury, Ricardo; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Feuchtner, Gudrun; Kim, Yong-Jin; Kaufmann, Philipp A; Leipsic, Jonathon; Lin, Fay Y; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J; Villines, Todd C; Dunning, Allison; Marques, Hugo; Rubinshtein, Ronen; Hindoyan, Niree; Gomez, Millie; Min, James K

    2017-03-15

    Non-obstructive coronary artery disease (CAD) identified by coronary computed tomography angiography (CCTA) demonstrated prognostic value. CT-adapted Leaman score (CT-LeSc) showed to improve the prognostic stratification. Aim of the study was to evaluate the capability of CT-LeSc to assess long-term prognosis of patients with non-obstructive (CAD). From 17 centers, we enrolled 2402 patients without prior CAD history who underwent CCTA that showed non-obstructive CAD and provided complete information on plaque composition. Patients were divided into a group without CAD and a group with non-obstructive CAD (CAD. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Best-Quality Vessel Identification Using Vessel Quality Measure in Multiple-Phase Coronary CT Angiography

    Science.gov (United States)

    Liu, Jordan; Chan, Heang-Ping; Zhou, Chuan; Wei, Jun; Chughtai, Aamer; Kuriakose, Jean; Agarwal, Prachi; Kazerooni, Ella

    2016-01-01

    The detection of stenotic plaques strongly depends on the quality of the coronary arterial tree imaged with coronary CT angiography (cCTA). However, it is time consuming for the radiologist to select the best-quality vessels from the multiple-phase cCTA for interpretation in clinical practice. We are developing an automated method for selection of the best-quality vessels from coronary arterial trees in multiple-phase cCTA to facilitate radiologist's reading or computerized analysis. Our automated method consists of vessel segmentation, vessel registration, corresponding vessel branch matching, vessel quality measure (VQM) estimation, and automatic selection of best branches based on VQM. For every branch, the VQM was calculated as the average radial gradient. An observer preference study was conducted to visually compare the quality of the selected vessels. 167 corresponding branch pairs were evaluated by two radiologists. The agreement between the first radiologist and the automated selection was 76% with kappa of 0.49. The agreement between the second radiologist and the automated selection was also 76% with kappa of 0.45. The agreement between the two radiologists was 81% with kappa of 0.57. The observer preference study demonstrated the feasibility of the proposed automated method for the selection of the best-quality vessels from multiple cCTA phases.

  11. Coronary CT angiography and MR angiography of Kawasaki disease

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Department of Radiology, Asan Medical Center, 388-1 Poongnap-2dong, Songpa-gu, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [University of Ulsan College of Medicine, Department of Paediatric Cardiology, Asan Medical Center, Seoul (Korea)

    2006-07-15

    Although the incidence of coronary artery aneurysms has diminished in patients with Kawasaki disease, coronary artery involvement is still regarded as a major complication of the disease, significantly affecting morbidity and mortality. Recent technical advances in coronary CT angiography (CTA) and MR angiography (MRA) have led to the possibility of using these two imaging methods as minimally invasive alternatives to the more invasive diagnostic catheter angiography in evaluating coronary artery abnormalities, such as aneurysm, stenosis, and occlusion. In this article, we describe imaging techniques and findings of coronary CTA and MRA in Kawasaki disease. (orig.)

  12. Changes in Medical Management after Coronary CT Angiography

    Directory of Open Access Journals (Sweden)

    Vânia Mairi Naue

    2015-01-01

    Full Text Available Abstract Introduction: Coronary computed tomography angiography (CCTA allows for non-invasive coronary artery disease (CAD phenotyping. There are still some uncertainties regarding the impact this knowledge has on the clinical care of patients. Objective: To determine whether CAD phenotyping by CCTA influences clinical decision making by the prescription of cardiovascular drugs and their impact on non-LDL cholesterol (NLDLC levels. Methods: We analysed consecutive patients from 2008 to 2011 submitted to CCTA without previous diagnosis of CAD that had two serial measures of NLDLC, one up to 3 months before CCTA and the second from 3 to 6 months after. Results: A total of 97 patients were included, of which 69% were men, mean age 64 ± 12 years. CCTA revealed that 18 (18% patients had no CAD, 38 (39% had non-obstructive (< 50% lesions and 41 (42% had at least one obstructive ≥ 50% lesion. NLDLC was similar at baseline between the grups (138 ± 52 mg/dL vs. 135 ± 42 mg/dL vs. 131 ± 44 mg/dL, respectively, p = 0.32. We found significative reduction in NLDLC among patients with obstrctive lesions (-18%, p = 0.001. We also found a positive relationship between clinical treatment intensification with aspirin and cholesterol reducing drugs and the severity of CAD. Conclusion: Our data suggest that CCTA results were used for cardiovascular clinical treatment titration, with especial intensification seen in patients with obstructive ≥50% CAD.

  13. Changes in Medical Management after Coronary CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Naue, Vânia Mairi, E-mail: vania_naue@yahoo.com.br; Camargo, Gabriel; Sabioni, Letícia Roberto; Lima, Ronaldo de Souza Leão; Derenne, Maria Eduarda; Lorenzo, Andréa Rocha de; Freire, Monica Di Calafiori; Azevedo Filho, Clério Francisco; Resende, Elmiro Santos; Gottlieb, Ilan [CDPI - Clínica de Diagnóstico por Imagem (Brazil)

    2015-10-15

    Coronary computed tomography angiography (CCTA) allows for non-invasive coronary artery disease (CAD) phenotyping. There are still some uncertainties regarding the impact this knowledge has on the clinical care of patients. To determine whether CAD phenotyping by CCTA influences clinical decision making by the prescription of cardiovascular drugs and their impact on non-LDL cholesterol (NLDLC) levels. We analysed consecutive patients from 2008 to 2011 submitted to CCTA without previous diagnosis of CAD that had two serial measures of NLDLC, one up to 3 months before CCTA and the second from 3 to 6 months after. A total of 97 patients were included, of which 69% were men, mean age 64 ± 12 years. CCTA revealed that 18 (18%) patients had no CAD, 38 (39%) had non-obstructive (< 50%) lesions and 41 (42%) had at least one obstructive ≥ 50% lesion. NLDLC was similar at baseline between the grups (138 ± 52 mg/dL vs. 135 ± 42 mg/dL vs. 131 ± 44 mg/dL, respectively, p = 0.32). We found significative reduction in NLDLC among patients with obstrctive lesions (-18%, p = 0.001). We also found a positive relationship between clinical treatment intensification with aspirin and cholesterol reducing drugs and the severity of CAD. Our data suggest that CCTA results were used for cardiovascular clinical treatment titration, with especial intensification seen in patients with obstructive ≥50% CAD.

  14. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience

    Energy Technology Data Exchange (ETDEWEB)

    Morsbach, Fabian; Gordic, Sonja; Husarik, Daniela; Frauenfelder, Thomas; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Desbiolles, Lotus; Leschka, Sebastian [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Kantonsspital St. Gallen, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Schmidt, Bernhard; Allmendinger, Thomas [Siemens AG, Healthcare Sector, Forchheim (Germany); Wildermuth, Simon [Kantonsspital St. Gallen, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland)

    2014-08-15

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. (orig.)

  15. Learning-based automatic detection of severe coronary stenoses in CT angiographies

    Science.gov (United States)

    Melki, Imen; Cardon, Cyril; Gogin, Nicolas; Talbot, Hugues; Najman, Laurent

    2014-03-01

    3D cardiac computed tomography angiography (CCTA) is becoming a standard routine for non-invasive heart diseases diagnosis. Thanks to its high negative predictive value, CCTA is increasingly used to decide whether or not the patient should be considered for invasive angiography. However, an accurate assessment of cardiac lesions using this modality is still a time consuming task and needs a high degree of clinical expertise. Thus, providing automatic tool to assist clinicians during the diagnosis task is highly desirable. In this work, we propose a fully automatic approach for accurate severe cardiac stenoses detection. Our algorithm uses the Random Forest classi cation to detect stenotic areas. First, the classi er is trained on 18 CT cardiac exams with CTA reference standard. Then, then classi cation result is used to detect severe stenoses (with a narrowing degree higher than 50%) in a 30 cardiac CT exam database. Features that best captures the di erent stenoses con guration are extracted along the vessel centerlines at di erent scales. To ensure the accuracy against the vessel direction and scale changes, we extract features inside cylindrical patterns with variable directions and radii. Thus, we make sure that the ROIs contains only the vessel walls. The algorithm is evaluated using the Rotterdam Coronary Artery Stenoses Detection and Quantication Evaluation Framework. The evaluation is performed using reference standard quanti cations obtained from quantitative coronary angiography (QCA) and consensus reading of CTA. The obtained results show that we can reliably detect severe stenosis with a sensitivity of 64%.

  16. Automatic coronary artery calcium scoring in cardiac CT angiography using paired convolutional neural networks.

    Science.gov (United States)

    Wolterink, Jelmer M; Leiner, Tim; de Vos, Bob D; van Hamersvelt, Robbert W; Viergever, Max A; Išgum, Ivana

    2016-12-01

    The amount of coronary artery calcification (CAC) is a strong and independent predictor of cardiovascular events. CAC is clinically quantified in cardiac calcium scoring CT (CSCT), but it has been shown that cardiac CT angiography (CCTA) may also be used for this purpose. We present a method for automatic CAC quantification in CCTA. This method uses supervised learning to directly identify and quantify CAC without a need for coronary artery extraction commonly used in existing methods. The study included cardiac CT exams of 250 patients for whom both a CCTA and a CSCT scan were available. To restrict the volume-of-interest for analysis, a bounding box around the heart is automatically determined. The bounding box detection algorithm employs a combination of three ConvNets, where each detects the heart in a different orthogonal plane (axial, sagittal, coronal). These ConvNets were trained using 50 cardiac CT exams. In the remaining 200 exams, a reference standard for CAC was defined in CSCT and CCTA. Out of these, 100 CCTA scans were used for training, and the remaining 100 for evaluation of a voxel classification method for CAC identification. The method uses ConvPairs, pairs of convolutional neural networks (ConvNets). The first ConvNet in a pair identifies voxels likely to be CAC, thereby discarding the majority of non-CAC-like voxels such as lung and fatty tissue. The identified CAC-like voxels are further classified by the second ConvNet in the pair, which distinguishes between CAC and CAC-like negatives. Given the different task of each ConvNet, they share their architecture, but not their weights. Input patches are either 2.5D or 3D. The ConvNets are purely convolutional, i.e. no pooling layers are present and fully connected layers are implemented as convolutions, thereby allowing efficient voxel classification. The performance of individual 2.5D and 3D ConvPairs with input sizes of 15 and 25 voxels, as well as the performance of ensembles of these Conv

  17. Single-centre cohort study of gender influence in coronary CT angiography in patients with a low to intermediate pretest probability of coronary heart disease

    DEFF Research Database (Denmark)

    Nørgaard, Kirsten Schou; Isaksen, Christin; Buhl, Jørgen Selmer;

    2015-01-01

    BACKGROUND: In 'real-world' patient populations undergoing coronary CT angiography (CCTA), it is unclear whether a correlation exists between gender, coronary artery calcium (CAC) score and subsequent referral for invasive coronary angiography and coronary revascularisation. We therefore investig......BACKGROUND: In 'real-world' patient populations undergoing coronary CT angiography (CCTA), it is unclear whether a correlation exists between gender, coronary artery calcium (CAC) score and subsequent referral for invasive coronary angiography and coronary revascularisation. We therefore...... investigated the relationship between gender, CAC and use of subsequent invasive coronary angiography and coronary revascularisation in a cohort of patients with chest discomfort and low to intermediate pretest probability of coronary artery disease who underwent a CCTA at our diagnostic centre. METHODS......-up was 28.5% in men versus 18.3% in women (pCAC-adjusted HR in women versus men was 0.98 (95% CI 0.85 to 1.13) for invasive coronary angiography and 0.73 (95% CI 0.57 to 0.93) for coronary...

  18. Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Zhou, Chang Sheng; Zhao, Yan E.; Li, Xie; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Wang, Yining; Cao, Jian; Jin, Zhengyu [Peking Union Medical College Hospital, Department of Radiology, Beijing (China); Schoepf, U.J. [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China); Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Meinel, Felix G. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Ludwig-Maximilians-University Hospital, Institute for Clinical Radiology, Munich (Germany); Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Charleston, SC (United States); Gong, Jian Bin [Jinling Hospital, Medical School of Nanjing University, Department of Cardiology, Nanjing, Jiangsu (China)

    2016-03-15

    To investigate image quality, radiation dose, and diagnostic performance of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) at 70 kVp compared to invasive coronary angiography (ICA) as reference standard. Forty-three patients underwent prospectively ECG-triggered high-pitch CCTA at 70 kVp using 30 cc (11 g iodine) contrast medium and ICA. Subjective and objective image quality was evaluated for each CCTA study. CCTA performance for diagnosing ≥50 % stenosis was assessed. Results were stratified according to heart rate (HR), body mass index (BMI), Agatston score, and image quality. At CCTA, 94.3 % (500/530) of coronary segments were of diagnostic quality. Using ICA as reference standard, sensitivity and accuracy were 100 % and 93.0 % on a per-patient basis. Per-vessel and per-segment performances were 92.2 % and 89.5 %; 79.5 % and 88.3 %, respectively. No differences were found in diagnostic accuracy between different HR, BMI, and calcification subgroups (all P > 0.05) on a per-patient basis. However, low image quality reduced diagnostic accuracy on a per-patient, per-vessel and per-segment basis (all P < 0.05). The mean effective radiation dose was 0.2 ± 0.0 mSv. Our presented protocol results in an effective radiation dose of 0.2 mSv and high diagnostic accuracy for stenosis detection in a selected, non-obese population. (orig.)

  19. CT angiography - abdomen and pelvis

    Science.gov (United States)

    Computed tomography angiography - abdomen and pelvis; CTA - abdomen and pelvis; Renal artery - CTA; Aortic - CTA; Mesenteric CTA ... belly or pelvis Masses and tumors in the abdomen or pelvis, including cancer, when needed to help ...

  20. Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT

    Science.gov (United States)

    Gu, Jin; Shi, He-Shui; Han, Ping; Yu, Jie; Ma, Gui-Na; Wu, Sheng

    2016-10-01

    This study sought to compare the image quality and radiation dose of coronary computed tomography angiography (CCTA) from prospectively triggered 128-slice CT (128-MSCT) versus dual-source 64-slice CT (DSCT). The study was approved by the Medical Ethics Committee at Tongji Medical College of Huazhong University of Science and Technology. Eighty consecutive patients with stable heart rates lower than 70 bpm were enrolled. Forty patients were scanned with 128-MSCT, and the other 40 patients were scanned with DSCT. Two radiologists independently assessed the image quality in segments (diameter >1 mm) according to a three-point scale (1: excellent; 2: moderate; 3: insufficient). The CCTA radiation dose was calculated. Eighty patients with 526 segments in the 128-MSCT group and 544 segments in the DSCT group were evaluated. The image quality 1, 2 and 3 scores were 91.6%, 6.9% and 1.5%, respectively, for the 128-MSCT group and 97.6%, 1.7% and 0.7%, respectively, for the DSCT group, and there was a statistically significant inter-group difference (P ≤ 0.001). The effective doses were 3.0 mSv in the 128-MSCT group and 4.5 mSv in the DSCT group (P ≤ 0.001). Compared with DSCT, CCTA with prospectively triggered 128-MSCT had adequate image quality and a 33.3% lower radiation dose.

  1. Coronary CT angiography-derived fractional flow reserve correlated with invasive fractional flow reserve measurements - initial experience with a novel physician-driven algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, Stefan [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); University Medical Centre Mannheim (UMM), University of Heidelberg, First Department of Medicine, Faculty of Medicine Mannheim, Mannheim (Germany); Wang, Rui [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Beijing Anzhen Hospital, Capital Medical University, Department of Radiology, Beijing (China); Schoepf, U.J.; Steinberg, Daniel H.; Spearman, James V.; Bayer, Richard R. [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Hamm, Christian W. [Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany); Renker, Matthias [Medical University of South Carolina, Heart and Vascular Center, Charleston, SC (United States); Giessen University, Department of Internal Medicine I, Cardiology/Angiology, Giessen (Germany)

    2015-04-01

    The present study aimed to determine the feasibility of a novel fractional flow reserve (FFR) algorithm based on coronary CT angiography (cCTA) that permits point-of-care assessment, without data transfer to core laboratories, for the evaluation of potentially ischemia-causing stenoses. To obtain CT-based FFR, anatomical coronary information and ventricular mass extracted from cCTA datasets were integrated with haemodynamic parameters. CT-based FFR was assessed for 36 coronary artery stenoses in 28 patients in a blinded fashion and compared to catheter-based FFR. Haemodynamically relevant stenoses were defined by an invasive FFR ≤0.80. Time was measured for the processing of each cCTA dataset and CT-based FFR computation. Assessment of cCTA image quality was performed using a 5-point scale. Mean total time for CT-based FFR determination was 51.9 ± 9.0 min. Per-vessel analysis for the identification of lesion-specific myocardial ischemia demonstrated good correlation (Pearson's product-moment r = 0.74, p < 0.0001) between the prototype CT-based FFR algorithm and invasive FFR. Subjective image quality analysis resulted in a median score of 4 (interquartile ranges, 3-4). Our initial data suggest that the CT-based FFR method for the detection of haemodynamically significant stenoses evaluated in the selected population correlates well with invasive FFR and renders time-efficient point-of-care assessment possible. (orig.)

  2. Post-mortem CT-coronary angiography

    DEFF Research Database (Denmark)

    Pøhlsgaard, Camilla; Leth, Peter Mygind

    2007-01-01

    post-mortem coronary angiography and computerized tomography.  We describe how to prepare and inject the contrast medium, and how to establish a CT-protocol that optimizes spatial resolution, low contrast resolution and noise level. Testing of the method on 6 hearts, showed that the lumen...

  3. Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Gordic, Sonja; Husarik, Daniela B.; Alkadhi, Hatem [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Desbiolles, Lotus; Leschka, Sebastian [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Kantonsspital, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland); Sedlmair, Martin; Schmidt, Bernhard [Siemens Healthcare, Computed Tomography Division, Forchheim (Germany); Manka, Robert [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); University Hospital Zurich, University of Zurich, Clinic of Cardiology, Zurich (Switzerland); University and ETH Zurich, Institute for Biomedical Engineering, Zurich (Switzerland); Plass, Andre; Maisano, Francesco [University Hospital Zurich, University of Zurich, Clinic for Cardiovascular Surgery, Zurich (Switzerland); Wildermuth, Simon [Kantonsspital, Divison of Radiology and Nuclear Medicine, St. Gallen (Switzerland)

    2016-02-15

    To evaluate the potential of advanced modeled iterative reconstruction (ADMIRE) for optimizing radiation dose of high-pitch coronary CT angiography (CCTA). High-pitch 192-slice dual-source CCTA was performed in 25 patients (group 1) according to standard settings (ref. 100 kVp, ref. 270 mAs/rot). Images were reconstructed with filtered back projection (FBP) and ADMIRE (strength levels 1-5). In another 25 patients (group 2), high-pitch CCTA protocol parameters were adapted according to results from group 1 (ref. 160 mAs/rot), and images were reconstructed with ADMIRE level 4. In ten patients of group 1, vessel sharpness using full width at half maximum (FWHM) analysis was determined. Image quality was assessed by two independent, blinded readers. Interobserver agreements for attenuation and noise were excellent (r = 0.88/0.85, p < 0.01). In group 1, ADMIRE level 4 images were most often selected (84 %, 21/25) as preferred data set; at this level noise reduction was 40 % compared to FBP. Vessel borders showed increasing sharpness (FWHM) at increasing ADMIRE levels (p < 0.05). Image quality in group 2 was similar to that of group 1 at ADMIRE levels 2-3. Radiation dose in group 2 (0.3 ± 0.1 mSv) was significantly lower than in group 1 (0.5 ± 0.3 mSv; p < 0.05). In a selected population, ADMIRE can be used for optimizing high-pitch CCTA to an effective dose of 0.3 mSv. (orig.)

  4. Coronary CT angiography in coronary artery disease: Opportunities and challenges

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2016-06-01

    Full Text Available Coronary CT angiography is widely recognised as a reliable imaging modality for the diagnosis of coronary artery disease. Coronary CT angiography not only provides excellent visualisation of anatomical changes in the coronary artery with high diagnostic value in the detection of lumen stenosis or occlusion, but also offers quantitative characterisation of coronary plaque components. Furthermore, coronary CT angiography allows myocardial perfusion imaging with diagnostic value comparable to the reference standard method. Coronary CT angiography-derived haemodynamic analysis has the potential to evaluate functional significance of coronary lesions. This review article aims to provide an overview of clinical applications of coronary CT angiography in coronary artery disease.

  5. Computer-aided stenosis detection at coronary CT angiography: effect on performance of readers with different experience levels

    Energy Technology Data Exchange (ETDEWEB)

    Thilo, Christian [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Herzzentrum Augsburg-Schwaben, Department of Cardiology, Klinikum Augsburg, Augsburg (Germany); Gebregziabher, Mulugeta [Medical University of South Carolina, Department of Biostatistics, Bioinformatics and Epidemiology, Charleston, SC (United States); Meinel, Felix G.; Arnoldi, Elisabeth M. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Ludwig-Maximilians-University Hospital Munich, Institute for Clinical Radiology, Munich (Germany); Goldenberg, Roman [Rcadia Medical Imaging, Haifa (Israel); Nance, John W.; Soma, Lashonda D.; Ebersberger, Ullrich; Blanke, Philip; Coursey, Richard L. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Rosenblum, Michael A.; Zwerner, Peter L. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2014-10-15

    To evaluate the effect of a computer-aided detection (CAD) algorithm for coronary CT angiography (cCTA) on the performance of readers with different experience levels. We studied 50 patients (18 women, 58 ± 11 years) who had undergone cCTA and quantitative coronary angiography (QCA). Eight observers with varying experience levels evaluated all studies for ≥50 % coronary artery stenosis. After 3 months, the same observers re-evaluated all studies, this time guided by a CAD system. Their performance with and without the CAD system (sensitivity, specificity, positive predictive value and negative predictive value) was assessed using the Likelihood Ratio Χ{sup 2} test both at the per-patient and per-vessel levels. The sensitivity of the CAD system alone for stenosis detection was 71 % per-vessel and 100 % per-patient. There were 54 false positive (FP) findings within 199 analyzed vessels, most of them associated with non-obstructive (<50 %) lesions. With CAD, one (out of three, 33 %) inexperienced reader's per-patient sensitivity and negative predictive value significantly improved from 79 % to 100 % (P = 0.046) and from 90 % to 100 % (P = 0.034), respectively. Other readers' performance indices showed no statistically significant change. Our results suggest that CAD can improve some inexperienced readers' sensitivity for diagnosing coronary artery stenosis at cCTA. (orig.)

  6. Cardiac CT Angiography in Congestive Heart Failure.

    Science.gov (United States)

    Levine, Avi; Hecht, Harvey S

    2015-06-01

    Cardiac CT angiography has become an important tool for the diagnosis and treatment of congestive heart failure. Differentiation of ischemic from nonischemic cardiomyopathy; evaluation of myocardial perfusion; characterization of hypertrophic cardiomyopathy, left ventricular noncompaction, and arrhythmogenic right ventricular dysplasia; and delineation of congenital heart defects and valvular abnormalities are the primary diagnostic applications. Therapeutic use includes visualization of the coronary venous anatomy for optimal implementation of cardiac resynchronization therapy and evaluation of left ventricular assist devices and transplant vasculopathy.

  7. Triple rule-out CT angiography protocol with restricting field of view for detection of pulmonary thromboembolism and aortic dissection in emergency department patients: simulation of modified CT protocol for reducing radiation dose.

    Science.gov (United States)

    Kim, Hyun Su; Kim, Sung Mok; Cha, Min Jae; Kim, Yoo Na; Kim, Hae Jin; Choi, Jin-Ho; Choe, Yeon Hyeon

    2017-05-01

    Background Triple rule-out computed tomography (TRO CT) is a CT protocol designed to simultaneously evaluate the coronary, aorta, and pulmonary arteries. Purpose To evaluate potential diagnostic performance of TRO CT with restricted volume coverage for detection of pulmonary thromboembolism (PTE) and aortic dissection (AD). Material and Methods This study included 1224 consecutive patients with acute chest pain who visited the emergency department and underwent TRO CT using a 128-slice dual-source CT. Image data were reconstructed according to the display field of view (DFOV) of coronary CT angiography (CCTA) and TRO CT protocols in each patient. The presence of PTE and AD was evaluated by independent observers in each DFOV. The radiation dose was calculated to evaluate the potential benefits by restricting z-axis coverage to cardiac scan range instead of the whole thorax. Results Among all patients, 22 cases with PTE (1.9%) and nine cases with AD (0.8%) were found. Except for one PTE case, all cases were detected on both DFOV of TRO CT and CCTA. Mean effective dose for evaluation of entire thorax and cardiac scan coverage were 5.9 ± 1.1 mSv and 3.5 ± 0.7 mSv, respectively. Conclusion Isolated PTE and AD outside the CCTA DFOV rarely occur. Therefore, modified TRO CT protocol using cardiac scan coverage can be adopted to detect PTE and AD with reduced radiation dose.

  8. Can segmented 3D images be used for stenosis evaluation in coronary CT angiography?

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Chunliang [Linkoeping Univ., Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping Univ., Div. of Radiological Sciences, Linkoeping (Sweden)], e-mail: chunliang.wang@liu.se; Persson, Anders; De Geer, Jakob; Smedby, Oerjan [Linkoeping Univ., Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping Univ., Div. of Radiological Sciences, Linkoeping (Sweden); Linkoeping Univ. Hospital, Dept. of Radiology, Linkoeping (Sweden); Engvall, Jan [Linkoeping Univ., Center for Medical Image Science and Visualization, Linkoeping (Sweden); Linkoeping Univ. Hospital, Dept. of Clinical Physiology, Linkoeping (Sweden); Czekierda, Waldemar; Bjoerkholm, Anders [Linkoeping Univ. Hospital, Dept. of Radiology, Linkoeping (Sweden); Fransson, Sven-Goeran [Linkoeping Univ., Div. of Radiological Sciences, Linkoeping (Sweden); Linkoeping Univ. Hospital, Dept. of Radiology, Linkoeping (Sweden)

    2012-10-15

    Background Thanks to the development of computed tomography (CT) scanners and computer software, accurate coronary artery segmentation can be achieved with minimum user interaction. However, the question remains whether we can use these segmented images for reliable diagnosis. Purpose To retrospectively evaluate the diagnostic accuracy of coronary CT angiography (CCTA) using segmented 3D data for the detection of significant stenosis. Material and Methods CCTA data-sets from 30 patients were acquired with a 64-slice CT scanner and segmented using the region growing (RG) method and the 'virtual contrast injection' (VC) method. Three types of images of each patient were reviewed by different reviewers for the presence of stenosis with diameter reduction of 50% or more. The evaluation was performed on four main arteries of each patient (120 arteries in total). For the original series, the reviewer was allowed to use all the 2D and 3D visualization tools available (conventional method). For the segmented results from RG and VC, only maximum intensity projection was used. Evaluation results were compared with catheter angiography (CA) for each artery in a blinded fashion. Results Overall, 34 arteries with significant stenosis were identified by CA. The percentage of evaluable arteries, accuracy and negative predictive value for detecting stenosis were, respectively, 86%, 74%, and 93% for the conventional method, 83%, 71%, and 92% for VC, and 64%, 56%, and 93% for RG. Accuracy was significantly lower for the RG method than for the other two methods (P < 0.01), whereas there was no significant difference in accuracy between the VC method and the conventional method (P = 0.22). Conclusion The diagnostic accuracy for the RG-segmented 3D data is lower than those with access to 2D images, whereas the VC method shows diagnostic accuracy similar to the conventional method.

  9. High-pitch coronary CT angiography in dual-source CT during free breathing vs. breath holding in patients with low heart rates

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, Bernhard, E-mail: bernhard.bischoff@med.uni-muenchen.de [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Meinel, Felix G. [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany); Del Prete, Alessandra [Department of Radiology Magrassi-Lanzara, Second University of Naples, Naples (Italy); Reiser, Maximilian F.; Becker, Hans-Christoph [Institute for Clinical Radiology, Ludwig-Maximilians-University Hospital Munich (Germany); DZHK (German Centre for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich (Germany)

    2013-12-01

    Background: Coronary CT angiography (CCTA) is usually performed during breath holding to reduce motion artifacts caused by respiration. However, some patients are not able to follow the breathing commands adequately due to deafness, hearing impairment, agitation or pulmonary diseases. The aim of this study was to evaluate the potential of high-pitch CCTA in free breathing patients when compared to breath holding patients. Methods: In this study we evaluated 40 patients (20 free breathing and 20 breath holding patients) with a heart rate of 60 bpm or below referred for CCTA who were examined on a 2nd generation dual-source CT system. Image quality of each coronary artery segment was rated using a 4-point grading scale (1: non diagnostic–4: excellent). Results: Mean heart rate during image acquisition was 52 ±5 bpm in both groups. There was no significant difference in mean image quality, slightly favoring image acquisition during breath holding (mean image quality score 3.76 ± 0.32 in breath holding patients vs. 3.61 ± 0.45 in free breathing patients; p = 0.411). Due to a smaller amount of injected contrast medium, there was a trend for signal intensity to be slightly lower in free breathing patients, but this was not statistically significant (435 ± 123 HU vs. 473 ± 117 HU; p = 0.648). Conclusion: In patients with a low heart rate who are not able to hold their breath adequately, CCTA can also be acquired during free breathing without substantial loss of image quality when using a high pitch scan mode in 2nd generation dual-source CT.

  10. Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols

    Energy Technology Data Exchange (ETDEWEB)

    Beitzke, D.; Berger-Kulemann, V.; Unterhumer, S.; Loewe, C.; Wolf, F. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Cardiovascular and Interventional Radiology, Vienna (Austria); Schoepf, V. [Medical University Vienna, Department of Biomedical Imaging and Image Guided Therapy, Division of Neuroradiology and Musculoskeletal Radiology, Vienna (Austria); Spitzer, E. [Bern University Hospital, Department of Cardiology, Bern (Switzerland); Feuchtner, G.M. [Innsbruck Medical University, Department of Radiology II, Innsbruck (Austria); Gyoengyoesi, M. [Medical University Vienna, Department of Cardiology, Vienna (Austria); Uyanik-Uenal, K.; Zuckermann, A. [Medical University Vienna, Department of Cardiac Surgery, Vienna (Austria)

    2015-08-15

    To prospectively evaluate image quality (IQ) and radiation dose of dual-source cardiac computed tomography (CCTA) using different imaging protocols. CCTA was performed in 150 patients using the retrospective ECG-gated spiral technique (rECG) the prospective ECG-gated technique (pECG), or the prospective ECG-gated technique with systolic imaging and automated tube voltage selection (pECGsys). IQ was rated using a 16-segment coronary artery model. Techniques were compared for overall IQ, IQ of the large and the small coronary artery segments. Effective dose was used for comparison of radiation dose. Overall IQ and IQ of the large segments showed no differences between the groups. IQ analysis of the small segments showed lowered IQ in pECGsys compared to rECG (p = 0.02), but not to pECG (p = 0.6). Effective dose did not differ significantly between rECG and pECG (p = 0.13), but was significantly lower for pECGsys (p < 0.001 vs. rECG and pECG). Radiation dose of dual-source CCTA in heart transplant recipients is significantly reduced by using prospective systolic scanning and automated tube voltage selection, while overall IQ and IQ of the large coronary segments are maintained. IQ appears to be lower compared to retrospective techniques with regard to small coronary segments. (orig.)

  11. Spiral CT angiography of renal arteries: comparison with angiography

    Energy Technology Data Exchange (ETDEWEB)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D. [Inst. fuer Roentgendiagnostik der Universitaet Wuerzburg (Germany)

    1999-04-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.) With 2 figs., 1 tab., 25 refs.

  12. Assessment of anemia during CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Caroline, E-mail: cjung@uke.de [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Groth, Michael; Bley, Thorsten A.; Henes, Frank O. [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Treszl, András [Department of Medical Biometry and Epidemiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany); Adam, Gerhard; Bannas, Peter [Department of Diagnostic and Interventional Radiology, University Hospital Eppendorf, Martinistrasse 52, 20246 Hamburg (Germany)

    2012-12-15

    Objectives: Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. Material and Methods: 150 consecutive patients (median age 64 ± 16 years) with suspected PE underwent pulmonary CT angiography. Two radiologists, blinded to laboratory results, performed HU measurements in the single unenhanced trigger scan independently by region-based analysis (ROI). HU values from ascending and descending aorta and the calculated mean of both were correlated with serum hemoglobin levels. Inter- and intraobserver variability was determined for HU measurements, and ROC analysis was performed for diagnosis of anemia. Calculated linear models were used to assess formulas for estimation of hemoglobin levels from HU measurements. Results: HU measurements revealed high intra- and interrater reliability (ICC > 0.981 and ICC > 0.965, respectively). Calculated mean HU values showed a strong correlation with serum hemoglobin levels (r = 0.734), which allowed generation of different formulas for calculation of hemoglobin levels from HU measurements. ROC analyses confirmed a high sensitivity (80.4 for men; 91.3 for women) and specificity (84.0 for men; 84.9 for women) for diagnosing anemia. Conclusion: Diagnosis of anemia and quantification of hemoglobin levels upon a single unenhanced trigger scan of pulmonary CT angiography is feasible. We suggest disclosing the anemic state in the radiological report, independent of the presence of PE, since anemia carries increased risks of morbidity and mortality.

  13. Coronary stent on coronary CT angiography: Assessment with model-based iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Chae; Kim, Yeo Koon; Chun, Eun Ju; Choi, Sang IL [Dept. of of Radiology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2016-05-15

    To assess the performance of model-based iterative reconstruction (MBIR) technique for evaluation of coronary artery stents on coronary CT angiography (CCTA). Twenty-two patients with coronary stent implantation who underwent CCTA were retrospectively enrolled for comparison of image quality between filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR) and MBIR. In each data set, image noise was measured as the standard deviation of the measured attenuation units within circular regions of interest in the ascending aorta (AA) and left main coronary artery (LM). To objectively assess the noise and blooming artifacts in coronary stent, we additionally measured the standard deviation of the measured attenuation and intra-luminal stent diameters of total 35 stents with dedicated software. All image noise measured in the AA (all p < 0.001), LM (p < 0.001, p = 0.001) and coronary stent (all p < 0.001) were significantly lower with MBIR in comparison to those with FBP or ASIR. Intraluminal stent diameter was significantly higher with MBIR, as compared with ASIR or FBP (p < 0.001, p = 0.001). MBIR can reduce image noise and blooming artifact from the stent, leading to better in-stent assessment in patients with coronary artery stent.

  14. Clinical evaluation of new automatic coronary-specific best cardiac phase selection algorithm for single-beat coronary CT angiography.

    Science.gov (United States)

    Wang, Hui; Xu, Lei; Fan, Zhanming; Liang, Junfu; Yan, Zixu; Sun, Zhonghua

    2017-01-01

    The aim of this study was to evaluate the workflow efficiency of a new automatic coronary-specific reconstruction technique (Smart Phase, GE Healthcare-SP) for selection of the best cardiac phase with least coronary motion when compared with expert manual selection (MS) of best phase in patients with high heart rate. A total of 46 patients with heart rates above 75 bpm who underwent single beat coronary computed tomography angiography (CCTA) were enrolled in this study. CCTA of all subjects were performed on a 256-detector row CT scanner (Revolution CT, GE Healthcare, Waukesha, Wisconsin, US). With the SP technique, the acquired phase range was automatically searched in 2% phase intervals during the reconstruction process to determine the optimal phase for coronary assessment, while for routine expert MS, reconstructions were performed at 5% intervals and a best phase was manually determined. The reconstruction and review times were recorded to measure the workflow efficiency for each method. Two reviewers subjectively assessed image quality for each coronary artery in the MS and SP reconstruction volumes using a 4-point grading scale. The average HR of the enrolled patients was 91.1±19.0bpm. A total of 204 vessels were assessed. The subjective image quality using SP was comparable to that of the MS, 1.45±0.85 vs 1.43±0.81 respectively (p = 0.88). The average time was 246 seconds for the manual best phase selection, and 98 seconds for the SP selection, resulting in average time saving of 148 seconds (60%) with use of the SP algorithm. The coronary specific automatic cardiac best phase selection technique (Smart Phase) improves clinical workflow in high heart rate patients and provides image quality comparable with manual cardiac best phase selection. Reconstruction of single-beat CCTA exams with SP can benefit the users with less experienced in CCTA image interpretation.

  15. Multislice CT angiography of interrupted aortic arch

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dong Hyun; Goo, Hyun Woo [Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea); Seo, Dong-Man; Yun, Tae-Jin; Park, Jeong-Jun [Asan Medical Center, University of Ulsan College of Medicine, Department of Paediatric Cardiac Surgery, Seoul (Korea); Park, In-Sook; Ko, Jae Kon; Kim, Young Hwee [Asan Medical Center, University of Ulsan College of Medicine, Department of Paediatric Cardiology, Seoul (Korea)

    2008-01-15

    Interrupted aortic arch (IAA) is defined as complete luminal and anatomic discontinuity between the ascending and descending aorta. Because almost all patients with IAA become critically ill during the neonatal period, they should undergo urgent corrective surgery. This clinical urgency necessitates a fast and accurate noninvasive diagnostic method. Although echocardiography remains the primary imaging tool for this purpose, it is not always sufficient for planning surgical correction of IAA, principally due to a limited acoustic window and the inexperience of imagers. In this context, multislice CT angiography is regarded as an appropriate imaging technique complementary to echocardiography because it is fast, accurate, and objective for the diagnosis of IAA. In this article we describe what cardiac radiologists should know about IAA in their clinical practice, including clinicopathological features, CT features with contemporary surgical methods and postoperative complications, and differentiation from coarctation of the aorta and aortic arch atresia. (orig.)

  16. Coronary CT angiography in symptomatic patients

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.R. [Inst. of Radiologic Diagnostic, Univ. of Munich, Klinikum Grosshadern, Munich (Germany)

    2005-02-01

    The currently best available spatial and temporal resolution for retrospectively ECG gated coronary multi-detector-row CT angiography is 0.4 mm and 165 ms, respectively. These acquisition parameters are already rather close to cardiac catheter. Studies so far compared non-invasive coronary CT and convention angiography for the detection of coronary artery stenoses. The most promising result reported by all authors was the high negative predictive value of the CTA. It now needs to be determined if CTA is a reliable tool to rule out coronary artery stenoses in a patient cohort with low likelihood of CAD, such as those with atypical chest pain or ambiguous stress test. CTA may furthermore establish as a rapid and widely available tool to detect vulnerable plaques or intracoronary thrombus in patients with acute coronary syndrome and unstable angina. In patients with chronic stable angina, tools that determine myocardial ischemia under stress such as SPECT and MRI are probably better suited to determine the relevance of coronary artery stenoses. In this particular cohort, by displaying the extent and morphology of coronary atherosclerosis, CTA may help to direct the therapy to either intervention or surgery. (orig.)

  17. Discordance between CT and angiography in the PIOPED II study.

    Science.gov (United States)

    Wittram, Conrad; Waltman, Arthur C; Shepard, Jo-Anne O; Halpern, Elkan; Goodman, Lawrence R

    2007-09-01

    To retrospectively evaluate the causes of discordant computed tomographic (CT)-angiographic readings from the Prospective Investigation of Pulmonary Embolism Diagnosis, or PIOPED, II study. Institutional review board approval was obtained for this HIPAA-compliant study. Of 1036 patients suspected of having pulmonary embolism who were examined with CT, 226 underwent angiography; 206 patients had concordant results and 20 had discordant results according to two independent readers. Of these 20 patients, 10 were men and 10 were women (mean age, 49 years). Among the 20 studies with discordant results, central readers identified seven cases as negative and 13 as positive for pulmonary embolism at CT; these findings were reversed at angiography. Side-by-side comparisons of discordant studies were performed in consensus. The time between CT and angiography and all locations of pulmonary embolism vascular territory were recorded. The McNemar binomial test was used. One patient had false-positive findings at angiography, 13 patients had false-negative findings at angiography, and two patients had false-negative findings at CT. Four patients had true-negative findings at CT; however, findings were positive for thrombus at angiography. The sensitivity for the detection of pulmonary embolism was 87% for CT and 32% for angiography (P=.007). The largest missed thrombus at angiography was subsegmental in eight patients, segmental in two patients, and lobar in three patients; at CT it was subsegmental in two patients. The mean time between CT and angiography was 40 hours+/-21 (standard deviation) (range, 10-97 hours). In the interval between CT and angiography, thrombi can remain the same, resolve, develop, or result from angiography. Copyright (c) RSNA, 2007.

  18. Step and shoot coronary CT angiography using 256-slice CT: effect of heart rate and heart rate variability on image quality

    Energy Technology Data Exchange (ETDEWEB)

    Muenzel, D.; Noel, P.B.; Dorn, F.; Dobritz, M.; Rummeny, E.J.; Huber, A. [Klinikum rechts der Isar der Technischen Universitaet Muenchen, Department of Radiology, Munich (Germany)

    2011-11-15

    To evaluate the effect of heart rate variability (HRV) and heart rate (HR) on intra-image ''motion'' and inter-image ''stairstep'' artefacts in step-and-shoot coronary CT angiography (CCTA) using a wide detector CT scanner. 66 patients underwent step-and-shoot CCTA using 256-slice CT. Patients were divided into two groups (Group 1: HR <65 bpm, Group 2 {>=}65bpm). Motion artefacts were quantified using a 5-point-scale. Stairstep artefacts were defined by measurements of misalignment. Image noise, contrast-to-noise-ratio (CNR), signal-to-noise-ratio (SNR), and radiation dose were assessed. Mean HR was 66 {+-} 16.7 bpm (range: 45-125 bpm) and mean HRV was 10.7 {+-} 17.5 bpm. A significant correlation between HR and stairstep artefacts (r = 0.46, p < 0.001) and motion artefacts (r = 0.63, p < 0.001) was found. Group 2 showed significantly increased step artefacts with a mean misalignment of 1.4 mm compared to 0.4 mm in Group 1 (p < 0.001). There was no significant effect of HRV on stairstep artefacts (r = 0.15, p = 0.416) and motion artefacts (r = 0.13, p = 0.311). No significant differences in image noise, CNR, SNR, and radiation dose were seen. Unlike CCTA using narrow CT detectors, HRV has no significant effect on motion and stairstep artefacts using a wide CT detector with high z-coverage. However, a higher HR still increases stairstep and motion artefacts. (orig.)

  19. Moyamoya disease: diagnosis with three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Kyorin Univ. School of Medicine, Tokyo (Japan)); Makita, K. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Radiology, Social Health Insurance Medical Center, Tokyo (Japan)); Furui, S. (Dept. of Radiology, National Defense Medical Coll., Saitama (Japan) Dept. of Diagnostic Radiology, Toranomon Kyosai Hospital, Tokyo (Japan))

    1994-08-01

    Our purpose was to assess the value of three-dimensional (3D) CT angiography in the diagnosis of moyamoya disease. We studied seven patients with moyamoya disease proved by conventional angiography. Three-dimensional (3D) CT angiography was performed using rapid sequence or helical (spiral) scanning in conjunction with a bolus injection of intravenous contrast medium. All seven patients could be diagnosed as having moyamoya disease on the basis of the following 3D CT angiographic findings: poor visualisation of the main trunks and/or major branches of anterior and middle cerebral arteries (7 patients); dilated leptomeningeal anastomotic channels from the posterior cerebral arteries (4); and demonstration of ''moyamoya vessels'' in the basal ganglia (2). Although conventional angiography remains the principal imaging technique for demonstrating anatomical changes in detail, less invasive 3D CT angiography provides a solid means of diagnosing moyamoya disease when it is suspected on CT, MRI, or clinical grounds. (orig.)

  20. Prospectively ECG-triggered sequential dual-source coronary CT angiography in patients with atrial fibrillation: comparison with retrospectively ECG-gated helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China); Wang, Yining; Jin, Zhengyu [Chinese Academy of Medical Sciences, Department of Radiology, Peking Union Medical College Hospital, Beijing (China); Zhang, Longjiang; Lu, Guangming [Nanjing University, Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing, Jiangsu (China)

    2013-07-15

    To investigate the feasibility of applying prospectively ECG-triggered sequential coronary CT angiography (CCTA) to patients with atrial fibrillation (AF) and evaluate the image quality and radiation dose compared with a retrospectively ECG-gated helical protocol. 100 patients with persistent AF were enrolled. Fifty patients were randomly assigned to a prospective protocol and the other patients to a retrospective protocol using a second-generation dual-source CT (DS-CT). Image quality was evaluated using a four-point grading scale (1 = excellent, 2 = good, 3 = moderate, 4 = poor) by two reviewers on a per-segment basis. The coronary artery segments were considered non-diagnostic with a quality score of 4. The radiation dose was evaluated. Diagnostic segment rate in the prospective group was 99.4 % (642/646 segments), while that in the retrospective group was 96.5 % (604/626 segments) (P < 0.001). Effective dose was 4.29 {+-} 1.86 and 11.95 {+-} 5.34 mSv for each of the two protocols (P < 0.001), which was a 64 % reduction in the radiation dose for prospective sequential imaging compared with retrospective helical imaging. In AF patients, prospectively ECG-triggered sequential CCTA is feasible using second-generation DS-CT and can decrease >60 % radiation exposure compared with retrospectively ECG-gated helical imaging while improving diagnostic image quality. (orig.)

  1. Diagnostic performance of coronary CT angiography, stress dual-energy CT perfusion, and stress perfusion single-photon emission computed tomography for coronary artery disease: Comparison with combined invasive coronary angiography and stress perfusion cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hyun Woo; Ko, Sung Min; Hwang, Hweung Kon; So, Young; Yi, Jeong Geun [Konkuk University Medical Center, Research Institute of Biomedical Science, Konkuk University School of Medicine, Seoul (Korea, Republic of); Lee, Eun Jeong [Dept. of Nuclear Medicine, Seoul Medical Center, Seoul (Korea, Republic of)

    2017-06-15

    To investigate the diagnostic performance of coronary computed tomography angiography (CCTA), stress dual-energy computed tomography perfusion (DE-CTP), stress perfusion single-photon emission computed tomography (SPECT), and the combinations of CCTA with myocardial perfusion imaging (CCTA + DE-CTP and CCTA + SPECT) for identifying coronary artery stenosis that causes myocardial hypoperfusion. Combined invasive coronary angiography (ICA) and stress perfusion cardiac magnetic resonance (SP-CMR) imaging are used as the reference standard. We retrospectively reviewed the records of 25 patients with suspected coronary artery disease, who underwent CCTA, DE-CTP, SPECT, SP-CMR, and ICA. The reference standard was defined as ≥ 50% stenosis by ICA, with a corresponding myocardial hypoperfusion on SP-CMR. For per-vascular territory analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 96, 96, 68, 93, and 68%, respectively, and specificities were 72, 75, 89, 85, and 94%, respectively. The areas under the receiver operating characteristic curve (AUCs) were 0.84 ± 0.05, 0.85 ± 0.05, 0.79 ± 0.06, 0.89 ± 0.04, and 0.81 ± 0.06, respectively. For per-patient analysis, the sensitivities of CCTA, DE-CTP, SPECT, CCTA + DE-CTP, and CCTA + SPECT were 100, 100, 89, 100, and 83%, respectively; the specificities were 14, 43, 57, 43, and 57%, respectively; and the AUCs were 0.57 ± 0.13, 0.71 ± 0.11, 0.73 ± 0.11, 0.71 ± 0.11, and 0.70 ± 0.11, respectively. The combination of CCTA and DE-CTP enhances specificity without a loss of sensitivity for detecting hemodynamically significant coronary artery stenosis, as defined by combined ICA and SP-CMR.

  2. Prognostic Value of Negative Coronary CT Angiography in Severely Obese Patients Prior to Bariatric Surgery: a Follow-Up After 6 Years.

    Science.gov (United States)

    Messerli, Michael; Maywald, Céline; Wälti, Stephan; Warschkow, René; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian; Schiesser, Marc

    2017-08-01

    This study aims to determine the long-term prognostic value of coronary CT angiography (CCTA) prior to bariatric surgery in severely obese patients with a body mass index (BMI) ≥35 kg/m(2). Seventy consecutive patients undergoing cardiac CT for coronary assessment prior to bariatric surgery were prospectively included. Images were analysed for the presence of coronary calcification and for non-obstructive (50% stenosis) coronary artery disease (CAD). A median clinical follow-up of 6.1 years in 54 patients was obtained for major adverse cardiovascular events (MACEs), defined as death, non-fatal myocardial infarction or coronary revascularisation. Weight loss and BMI decrease following bariatric surgery were recorded. The median BMI prior to surgery was 46.9 kg/m(2). The median percentage of excess BMI loss after surgery was 75%. CT showed coronary calcification in 26 (48%) patients, whereas 28 (52%) patients had no calcification. CCTA revealed normal coronaries in 47 (87%) and non-obstructive CAD in 7 (13%) patients. No obstructive CAD was found. All patients successfully underwent bariatric surgery, and no MACE occurred neither perioperatively nor in the follow-up period. The negative predictive value of CCTA was 100% (95% confidence interval of 90.1-100.0%). In severely obese patients, the absence of obstructive CAD in cardiac CT prior to bariatric surgery with subsequently marked weight reduction has strong long-term prognostic implications for ruling out major adverse cardiac events in the postoperative period.

  3. Diagnostic value of quantitative stenosis predictors with coronary CT angiography compared to invasive fractional flow reserve

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Rui [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, 100029 Beijing (China); Renker, Matthias [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Kerckhoff Heart and Thorax Center, Benekestrasse 2-8, 61231 Bad Nauheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Wichmann, Julian L. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Fuller, Stephen R.; Rier, Jeremy D.; Bayer, Richard R.; Steinberg, Daniel H. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); De Cecco, Carlo N. [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); Departments of Radiological Sciences, Oncology, and Pathology, University of Rome “Sapienza”-Polo Pontino, Latina, Viale Regina Elena, 324-00161 Roma (Italy); Baumann, Stefan [Heart & Vascular Center, Medical University of South Carolina, Ashley River Tower, 25 Courtenay Drive Charleston, SC 29425-2260 (United States); First Department of Medicine, University Medical Centre Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2015-08-15

    Highlights: • Evaluation of the diagnostic performance of CCTA predictors for coronary stenosis. • TAG was unable to detect hemodynamically significant coronary lesions. • CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA. • CT-FFR was the best parameter. - Abstract: Objective: To evaluate the diagnostic performance of CCTA-derived stenosis predictors including CT-FFR for the detection of ischemia-inducing stenosis compared to invasive FFR. Materials and methods: Stenosis parameters were assessed using dual-source CT (DSCT). All patients underwent both CCTA and invasive FFR within 3 months and were retrospectively analyzed. Observers visually assessed all CCTA studies and performed multiple lesion measurements. Lesion length/minimal luminal diameter{sup 4} (LL/MLD{sup 4}), transluminal attenuation gradient (TAG), corrected coronary attenuation (CCO) and CT-FFR were calculated. Results: The cohort included 32 patients (58 ± 12 years, 66%male). Among 32 coronary lesions, 8 (25%) were considered hemodynamically significant with an FFR <0.80. Compared to invasive FFR, the per-vessel sensitivity and specificity of CCTA, CT-FFR, LL/MLD{sup 4}, CCO and TAG for detecting hemodynamically significant lesions were 100% and 54%, 100% and 91%, 85% and 92%, 66% and 88%, 37% and 58%, respectively. Receiver operating characteristics analysis resulted in an area under the curve of 0.91 for CT-FFR (p = 0.0005), 0.88 for LL/MLD{sup 4} (p < 0.0001), 0.85 for CCO (p < 0.0001). TAG with an AUC of 0.67 (p = 0.152) was unable to discriminate between vessels with or without hemodynamically significant lesions. Conclusion: CT-FFR, LL/MLD{sup 4} and CCO provide enhanced diagnostic performance over CCTA analysis alone for discrimination of hemodynamically significant coronary stenosis.

  4. Feasibility of prospectively ECG-triggered high-pitch coronary CT angiography with 30 mL iodinated contrast agent at 70 kVp: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Long Jiang; Qi, Li; Tang, Chun Xiang; Zhou, Chang Sheng; Ji, Xue Man; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Wang, Jing [Medical School of Nanjing University, Department of Cardiology, Jinling Hospital, Nanjing, Jiangsu (China); Spearman, James V.; De Cecco, Carlo Nicola; Meinel, Felix G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2014-07-15

    To evaluate the feasibility, image quality and radiation dose of prospectively ECG-triggered high-pitch coronary CT angiography (CCTA) with 30 mL contrast agent at 70 kVp. Fifty-eight patients with suspected coronary artery disease, a body mass index (BMI) of less than 25 kg/m{sup 2}, sinus rhythm and a heart rate (HR) of less than 70 beats per minute (bpm) were prospectively enrolled in this study. Thirty mL of 370 mg I/mL iodinated contrast agent was administrated at a flow rate of 5 mL/s. All patients underwent prospectively ECG-triggered high-pitch CCTA on a second-generation dual-source CT system at 70 kVp using automated tube current modulation. Fifty-six patients (96.6 %) had diagnostic CCTA images and two patients (3.4 %) had one vessel with poor image quality each rated as non-diagnostic. No significant effects of HR, HR variability and BMI on CCTA image quality were observed (all P > 0.05). Effective dose was 0.17 ± 0.02 mSv and the size-specific dose estimate was 1.03 ± 0.13 mGy. Prospectively ECG-triggered high-pitch CCTA at 70 kVp with 30 mL of contrast agent can provide diagnostic image quality at a radiation dose of less than 0.2 mSv in patients with a BMI of less than 25 kg/m{sup 2} and an HR of less than 70 bpm. (orig.)

  5. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  6. Quantification of left coronary bifurcation angles and plaques by coronary computed tomography angiography for prediction of significant coronary stenosis: A preliminary study with dual-source CT

    Science.gov (United States)

    Cui, Yue; Zeng, Wenjuan; Yu, Jie; Lu, Jing; Hu, Yuannan; Diao, Nan; Liang, Bo; Han, Ping; Shi, Heshui

    2017-01-01

    Purpose To evaluate the diagnostic performance of left coronary bifurcation angles and plaque characteristics for prediction of coronary stenosis by dual-source CT. Methods 106 patients suspected of coronary artery disease undergoing both coronary computed tomography angiography (CCTA) and invasive coronary angiography (CAG) within three months were included. Left coronary bifurcation angles including the angles between the left anterior descending artery and left circumflex artery (LAD-LCx), left main coronary artery and left anterior descending artery (LM-LAD), left main coronary artery and left circumflex artery (LM-LCx) were measured on CT images. CCTA plaque parameters were calculated by plaque analysis software. Coronary stenosis ≥ 50% by CAG was defined as significant. Results 106 patients with 318 left coronary bifurcation angles and 126 vessels were analyzed. The bifurcation angle of LAD-LCx was significantly larger in left coronary stenosis ≥ 50% than stenosis coronary stenosis (OR = 1.423, P = 0.002). In ROC curve analysis, LAD-LCx predicted significant left coronary stenosis with a sensitivity of 66.7%, specificity of 78.4%, positive predictive value of 85.2% and negative predictive value of 55.8%. The lipid plaque volume improved the diagnostic performance of CCTA diameter stenosis (AUC: 0.854 vs. 0.900, P = 0.045) in significant coronary stenosis. Conclusions The bifurcation angle of LAD-LCx could predict significant left coronary stenosis. Wider LAD-LCx is related to non-calcified lesions. Lipid plaque volume could improve the diagnostic performance of CCTA for coronary stenosis prediction. PMID:28346530

  7. Automated selection of the optimal cardiac phase for single-beat coronary CT angiography reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Stassi, D.; Ma, H.; Schmidt, T. G., E-mail: taly.gilat-schmidt@marquette.edu [Department of Biomedical Engineering, Marquette University, Milwaukee, Wisconsin 53201 (United States); Dutta, S.; Soderman, A.; Pazzani, D.; Gros, E.; Okerlund, D. [GE Healthcare, Waukesha, Wisconsin 53188 (United States)

    2016-01-15

    Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, making it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiac CT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three

  8. Coronary CT Angiography as a Diagnostic and Prognostic Tool: Perspectives from the SCOT-HEART Trial.

    Science.gov (United States)

    Doris, Mhairi; Newby, David E

    2016-02-01

    Coronary artery disease is the leading cause of death worldwide. Many trials to date have investigated the diagnostic accuracy of coronary computed tomography angiography (CCTA) when compared to the gold standard diagnostic test, invasive coronary angiography. However, whether the use of a non-invasive anatomical test, such as CCTA, can translate into improved patient risk stratification, management and outcome has yet to be established. The Scottish COmputed Tomography of the HEART (SCOT-HEART) trial sought to address these questions and determined whether CCTA, when used in addition to standard care, could aid the diagnosis, further investigation and treatment of patients referred to the cardiology clinic with suspected angina due to coronary heart disease. In this trial, CCTA clarified the diagnosis of angina due to coronary heart disease in a quarter of patients and this led to major alterations in treatment and management that appeared to reduce the risk of subsequent coronary heart disease death or non-fatal myocardial infarction. The SCOT-Heart trial has established that CCTA is a valuable diagnostic test in patients with suspected angina pectoris due to coronary heart disease and leads to greater clarity, more focused appropriate treatments and better coronary heart disease outcomes.

  9. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  10. Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: A comparison between patients with chronic Atrial Fibrillation and subjects in normal sinus rhythm by propensity analysis

    Energy Technology Data Exchange (ETDEWEB)

    Di Cesare, Ernesto, E-mail: ernesto.dicesare@cc.univaq.it [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Gennarelli, Antonio; Di Sibio, Alessandra; Felli, Valentina; Splendiani, Alessandra [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy); Gravina, Giovanni Luca [Department of Biotechnological and Applied Clinical Sciences, Division of Radiotherapy, Laboratory of Radiobiology, University of L’Aquila (Italy); Masciocchi, Carlo [Department of Biotechnological and Applied Clinical Sciences, Division of Radiology, Laboratory of Radiobiology, University of L’Aquila (Italy)

    2015-04-15

    Highlights: •Atrial Fibrillation (AF) may affect CCTA image quality. •We compare the results of single heartbeat CCTA in subjects with chronic AF and in sinus rhythm. •Single heartbeat CCTA may be feasible also in subjects with cAF and HR <72 bpm. •In cAF patients with heart rate higher than 72 bpm, CCTA has more movement-associated artefacts. •Mean effective dose of single heartbeat CCTA in cAF group was higher than in sinus rhythm one. -- Abstract: Objectives: To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. Methods: A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) and HR ≤ 65 bpm using a matched by propensity analysis. All subjects underwent a single heartbeat CCTA with prospective gating. In subjects with cAF, we manually established the acquisition of data only from a single heartbeat. Mean effective dose and image quality, with both objective and subjective measures, were assessed. Results: 96.4% of all segments in the cAF group had diagnostic image quality. The rate of subjects with at least one non-diagnostic segment was 14% and 2.8% (p = 0.031) in the cAF and NRS groups, respectively. In the cAF group, the percentage of patients with at least one non-diagnostic segment for acquisition HR ≤ 72 was 1.8% (1/55), and it did not significantly differ from the NSR group (2.8%; 2/71) (p = 1.0). Objective quality parameters did not show a statistically significant difference between the two groups. The mean effective dose was 4.24 ± 1.24 mSv in the cAF group and 2.67 ± 0.5 mSv in the sinus rhythm group (p < 0.0001) with an increase by 59% in the cAF group with respect to the SNR group. Conclusions: A single heartbeat acquisition protocol with a 640-slice prospectively ECG-triggered CT angiography may be feasible in patients with cAF and HR below 72

  11. Step-and-shoot prospectively ECG-gated versus retrospectively ECG-gated with tube current modulation coronary CT angiography using the 128-slice MDCT: comparison of image quality and radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Dong Wook (Dept. of Family Medicine, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do, (Korea, Republic of)); Choo, Ki Seok; Baik, Seung Kug; Kim, Yong Woo; Jeon, Ung Bae (Dept. of Radiology, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do, (Korea, Republic of)), email: kschoo0618@naver.com; Kim, Jeong Soo (Dept. of Cardiology, Medial Research Institute, Pusan National Univ. Yangsan Hospital, School of Medicine, Gyeongsangnam-do (Korea, Republic of)); Lim, Soo Jin (Dept. of Cardiology, Kim Hae Joongang Hospital, Gyeongsangnam-do (Korea, Republic of))

    2011-02-15

    Background: Little is known regarding image quality and the required radiation dose for step-and-shoot and retrospective coronary computed tomography angiography (CCTA) with tube current modulation (TCM) in 128-slice multidetector CT (MDCT) coronary angiography. Purpose: To compare image quality and radiation dose in patients who underwent 128-slice MDCT by the step-and- shoot method with those in patients who underwent 128-slice MDCT with retrospective CCTA with TCM. Material and Methods: CCTA obtained with 128-slice MDCT was retrospectively evaluated in 160 patients. Two independent reviewers separately scored the subjective image quality of the coronary artery segments (1, excellent; 4, poor) for step-and-shoot (68, mean heart rate [HR]: 59.3+-6.8) and retrospective CCTA with TCM (77, mean HR: 59.1+-9.8). Interobserver variability was calculated. Effective radiation doses of both scan techniques were calculated with dose-length product. Results: There was good agreement for quality scores of coronary artery segment images between the independent reviewers (k=0.72). The number of coronary artery segments that could not be evaluated was 2.85% (27 of 947) in the step-and-shoot and 1.87% (20 of 1071) in retrospective CCTA with TCM. Image quality scores were not significantly different (P>.05). Mean patient radiation dose was 63% lower for step-and-shoot (1.94+-0.70 mSv) than for retrospective CCTA with TCM (4.51+-1.18 mSv) (P<0.0001). For patients who underwent step-and-shoot or retrospective CCTA with TCM, an average HR of 63.5 beats per minute was identified as the threshold for the prediction of non-diagnostic image quality for both protocols. There were no significant differences in the image quality of both methods between obese (body mass index [BMI>=25) and non-obese patients (BMI<25), but radiation doses were higher in the obesity group than in the non-obesity group for both methods. Conclusion: Both step-and-shoot and retrospective CCTA with TCM using 128

  12. Diagnostic accuracy and utility of coronary CT angiography with consideration of unevaluable results: A systematic review and multivariate Bayesian random-effects meta-analysis with intention to diagnose

    Energy Technology Data Exchange (ETDEWEB)

    Menke, Jan [University Medical Center Goettingen, Institute for Diagnostic and Interventional Radiology, Goettingen (Germany); Kowalski, Joerg [Dr. Lauterbach-Klinik, Department of Cardiology, Bad Liebenstein (Germany)

    2016-02-15

    To meta-analyze diagnostic accuracy, test yield and utility of coronary computed tomography angiography (CCTA) in coronary artery disease (CAD) by an intention-to-diagnose approach with inclusion of unevaluable results. Four databases were searched from 1/2005 to 3/2013 for prospective studies that used 16-320-row or dual-source CTs and provided 3 x 2 patient-level data of CCTA (positive, negative, or unevaluable) versus catheter angiography (positive or negative) for diagnosing ≥50 % coronary stenoses. A Bayesian multivariate 3 x 2 random-effects meta-analysis considered unevaluable CCTAs. Thirty studies (3422 patients) were included. Compared to 16-40 row CT, test yield and accuracy of CCTA has significantly increased with ≥64-row CT (P < 0.05). In ≥64-row CT, about 2.5 % (95 %-CI, 0.9-4.8 %) of diseased patients and 7.5 % (4.5-11.2 %) of non-diseased patients had unevaluable CCTAs. A positive likelihood ratio of 8.9 (6.1-13.5) indicated moderate suitability for identifying CAD. A negative likelihood ratio of 0.022 (0.01-0.04) indicated excellent suitability for excluding CAD. Unevaluable CCTAs had an equivocal likelihood ratio of 0.42 (0.22-0.71). In the utility analysis, CCTA was useful at intermediate pre-test probabilities (16-70 %). CCTA is useful at intermediate CAD pre-test probabilities. Positive CCTAs require verification to confirm CAD, unevaluable CCTAs require alternative diagnostics, and negative CCTAs exclude obstructive CAD with high certainty. (orig.)

  13. Subtraction CT angiography for evaluation of intracranial aneurysms: comparison with conventional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, Qi; Li, Kewei; Xie, Peng [The First Affiliated Hospital, Chongqing Medical University, Department of Neurology, Chongqing (China); Lv, Fajin; Li, Yongmei; Luo, Tianyou [The First Affiliated Hospital, Chongqing Medical University, Department of Radiology, Chongqing (China)

    2009-09-15

    The purpose of our study was to compare the diagnostic performance of subtraction computed tomography angiography (CTA) with conventional nonsubtracted CTA and digital subtraction angiography (DSA) for the detection of intracranial aneurysms. A total of 76 patients underwent both subtraction CTA and conventional CTA for the detection and therapy planning of suspected intracranial aneurysms. Subtraction and conventional CTA images were independently assessed by two readers in a blinded manner. The possibility of endovascular treatment or surgical clipping was also assessed based on information provided by CT angiograms alone. In 64 patients, 75 aneurysms were present on DSA. On a per-aneurysm basis, the sensitivity of subtraction CTA was 98.6% for reader 1, and 100% for reader 2. However, sensitivity of conventional CTA was 94.6% for reader 1, and 93.3% for reader 2. Therapeutic decisions could be made regarding 63 patients based on information provided by subtraction CTA images. However, conventional CTA provided sufficient information to make this decision for 55 patients. Conventional CTA has limited sensitivity in detecting very small aneurysms as well as aneurysms adjacent to bone. Subtraction CTA performed on a 64-row multidetector CT is an accurate and promising diagnostic tool that seems to be equivalent to 2D DSA for the detection and pretreatment planning of intracranial aneurysms. (orig.)

  14. Coronary CT angiography: Comparison of a novel iterative reconstruction with filtered back projection for reconstruction of low-dose CT—Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Takx, Richard A.P. [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Moscariello, Antonio [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Policlinico Universitario Campus Bio-Medico, Rome (Italy); Das, Marco [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Rowe, Garrett [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoenberg, Stefan O.; Fink, Christian [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany); Henzler, Thomas [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University (Germany)

    2013-02-15

    Objective: To prospectively compare subjective and objective image quality in 20% tube current coronary CT angiography (cCTA) datasets between an iterative reconstruction algorithm (SAFIRE) and traditional filtered back projection (FBP). Materials and methods: Twenty patients underwent a prospectively ECG-triggered dual-step cCTA protocol using 2nd generation dual-source CT (DSCT). CT raw data was reconstructed using standard FBP at full-dose (Group{sub 1}a) and 80% tube current reduced low-dose (Group{sub 1}b). The low-dose raw data was additionally reconstructed using iterative raw data reconstruction (Group{sub 2}). Attenuation and image noise were measured in three regions of interest and signal-to-noise-ratio (SNR) as well as contrast-to-noise-ratio (CNR) was calculated. Subjective diagnostic image quality was evaluated using a 4-point Likert scale. Results: Mean image noise of group{sub 2} was lowered by 22% on average when compared to group{sub 1}b (p < 0.0001–0.0033), while there were no significant differences in mean attenuation within the same anatomical regions. The lower image noise resulted in significantly higher SNR and CNR ratios in group{sub 2} compared to group{sub 1}b (p < 0.0001–0.0232). Subjective image quality of group{sub 2} (1.88 ± 0.63) was also rated significantly higher when compared to group{sub 1}b (1.58 ± 0.63, p = 0.004). Conclusions: Image quality of 80% tube current reduced iteratively reconstructed cCTA raw data is significantly improved when compared to standard FBP and consequently may improve the diagnostic accuracy of cCTA.

  15. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  16. 320-row CT coronary angiography predicts freedom from revascularisation and acts as a gatekeeper to defer invasive angiography in stable coronary artery disease: a fractional flow reserve-correlated study

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Brian S.; Wong, Dennis T.L.; Cameron, James D.; Leung, Michael; Meredith, Ian T.; Nerlekar, Nitesh; Antonis, Paul; Harper, Richard; Malaiapan, Yuvaraj; Seneviratne, Sujith K. [Southern Health and Monash University, Monash Cardiovascular Research Centre, MonashHEART, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Leong, Darryl P. [University of Adelaide, Discipline of Medicine, Adelaide (Australia); Flinders University, Adelaide (Australia); Crossett, Marcus; Troupis, John [Southern Health and Monash University, Monash Cardiovascular Research Centre, MonashHEART, Department of Medicine Monash Medical Centre (MMC), Melbourne (Australia); Southern Health and Monash University, Department of Diagnostic Imaging, MMC, Melbourne (Australia)

    2014-03-15

    To determine the accuracy of 320-row multidetector coronary computed tomography angiography (M320-CCTA) to detect functional stenoses using fractional flow reserve (FFR) as the reference standard and to predict revascularisation in stable coronary artery disease. One hundred and fifteen patients (230 vessels) underwent M320-CCTA and FFR assessment and were followed for 18 months. Diameter stenosis on invasive angiography (ICA) and M320-CCTA were assessed by consensus by two observers and significant stenosis was defined as ≥50 %. FFR ≤0.8 indicated functionally significant stenoses. M320-CCTA had 94 % sensitivity and 94 % negative predictive value (NPV) for FFR ≤0.8. Overall accuracy was 70 %, specificity 54 % and positive predictive value 65 %. On receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) for CCTA to predict FFR ≤0.8 was 0.74 which was comparable with ICA. The absence of a significant stenosis on M320-CCTA was associated with a 6 % revascularisation rate. M320-CCTA predicted revascularisation with an AUC of 0.71 which was comparable with ICA. M320-CCTA has excellent sensitivity and NPV for functional stenoses and therefore may act as an effective gatekeeper to defer ICA and revascularisation. Like ICA, M320-CCTA lacks specificity for functional stenoses and only has moderate accuracy to predict the need for revascularisation. (orig.)

  17. Multislice Cardiac CT-Angiography; A Review on Accepted Indications and Potentials for Other Applications Regarding the Newest Development

    Directory of Open Access Journals (Sweden)

    M. Motevalli

    2007-05-01

    Full Text Available There were not any clear-cut criteria available for clinical use of cardiac CT-angiography (CCTA up to October 2006 in which the American College of Car-diology (ACC, American College of Radiology (ACR and six other medical institutions released a joint consensus on clinical indications of cardiac CT and MRI. A statement was released by the American Heart Association together with two other radiology and cardiology institutions in the same month on the same matter. An illustrated review will be presented on the newly accepted indications of cardiac CT, especially CCTA. Some prominent indications are as follow: 1. Evaluation of chest pain syndrome in patient with intermediate pretest probability of coronary artery disease (CAD when exercise test is not feasible. 2. Evaluation of acute chest pain in patient with in-termediate pretest probability of CAD and negative ECG and enzymes. 3. Uninterpretable or equivocal stress test (exercise, perfusion scan, or stress echo. 4. Evaluation of coronary arteries in patients with new onset heart failure. 5. Assessment of congenital coronary and cardiac anomalies. 6. Noninvasive coronary vein mapping prior to placement of biventricular pacemaker. 7. Noninvasive coronary arterial mapping, including internal mammary artery prior to repeat cardiac sur-gical revascularization. Some recent research indicated that CCTA is useful in some other specific situations too, like evaluating in-stent re-stenosis for stainless steel or cobalt stents more than 3mm in diameter and has also some roles in the evaluation of coronary bypass grafts, etc. Fi-nally, the newer progressions in the field of multislice CT are promising of even better performance which may widen the scope of its indications. Dual-source CT scanners have shown better performance com-pared with 64-slice CT scanners in the preliminary studies, namely slice-thickness of 0.25mm vs. 0.4mm, temporal resolution of 83ms vs.165ms, assessable segments of 98.6% vs. 97

  18. Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wei, Jun, E-mail: jvwei@umich.edu; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella [Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2014-08-15

    Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features

  19. Diagnostic accuracy of CT angiography in acute gastrointestinal bleeding.

    Science.gov (United States)

    Chua, A E; Ridley, L J

    2008-08-01

    The aim of the study was to carry out a systematic review determining the accuracy of CT angiography in the diagnosis of acute gastrointestinal bleeding. A search of published work in Medline and manual searching of reference lists of articles was conducted. Studies were included if they compared CT angiography to a reference standard of upper gastrointestinal endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute gastrointestinal bleeding. Eight published studies evaluating 129 patients were included. Data were used to form 2 x 2 tables. Computed tomography angiography showed pooled sensitivity of 86% (95% confidence interval 78-92%) and specificity of 95% (95% confidence interval 76-100%), without showing significant heterogeneity (chi(2) = 3.5, P = 0.6) and (chi(2) = 5.4, P = 0.6), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.93. Computed tomography angiography is accurate in the diagnosis of acute gastrointestinal bleeding and can show the precise location and aetiology of bleeding, thereby directing further management. Strong recommendations for use of CT cannot be made from this review because of the methodological limitations and further large prospective studies are needed to define the role of CT in acute gastrointestinal bleeding.

  20. Improved non-calcified plaque delineation on coronary CT angiography by sonogram-affirmed iterative reconstruction with different filter strength and relationship with BMI.

    Science.gov (United States)

    Zhao, Lei; Plank, Fabian; Kummann, Moritz; Burghard, Philipp; Klauser, Andrea; Dichtl, Wolfgang; Feuchtner, Gudrun

    2015-04-01

    To prospectively compare non-calcified plaque delineation and image quality of coronary computed tomography angiography (CCTA) obtained with sinogram-affirmed iterative reconstruction (IR) with different filter strengths and filtered back projection (FBP). A total of 57 patients [28.1% females; body mass index (BMI) 29.2±6.5 kg/m(2)] were investigated. CCTA was performed using 128-slice dual-source CT. Images were reconstructed with standard FBP and sinogram-affirmed IR using different filter strength (IR-2, IR-3, IR-4) (SAFIRE, Siemens, Germany). Image quality of CCTA and a non-calcified plaque outer border delineation score were evaluated by using a 5-scale score: from 1= poor to 5= excellent. Image noise, contrast-to-noise ratio (CNR) of aortic root, left main (LM) and right coronary artery, and the non-calcified plaque delineation were quantified and compared among the 4 image reconstructions, and were compared between different BMI groups (BMI BMI groups within same reconstruction (all P>0.05). Significant differences in image quality and plaque delineation scores among different image reconstructions both in low and high BMI groups (all PBMI is increasing. Importantly, 18% of non-calcified plaques were missed with FBP. IR-4 shows the best image quality score and plaque delineation score among the different IR-filter strength.

  1. CT angiography by means of intra-arterial contrast infusion

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Junichiro; Watanabe, Hiroshi; Shiogai, Toshiyuki; Konishi, Yoshifumi; Hara, Mitsuhiro (Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine)

    1983-10-01

    CT angiography (CT-AG) by means of intra-arterial contrast infusion was carried out, and its clinical usefulness was evaluated in various intracranial lesions. The practical and diagnostic merits of CT-AG are as follows: a selective enhancement of the cerebral vessels by an extremely small amount of the contrast substance, accompanied by a satisfactory resolution of fine arterioles and arteries. The excellent ability of the CT to detect differences in the X-ray absorption coefficients surpasses that of cerebral angiography. An intracranial aneurysm which was not visualized by the angiography appeared between arterial branches upon CT-AG. The three-dimensional configuration of the aneurysmal body and its related artery, the pointing direction of the aneurysm, and the angle between the aneurysmal axis and the afferent artery were clearly shown. The fine structure of arteriovenous malformation could be shown concurrently with the cerebral tissue and the ventricle. The axial view of the circle of Willis gives important information for surgical intervention. Concerning brain tumors, the structural correlation between the tumor and the cerebral arteries became apparent when the CT-AG was carried out immediately after a conventional contrast-enhancement. Such a ''double contrast'' allows safe surgical access to the intracranial tumor. CT-AG in the case of ''Moyamoya'' disease visualized fine moyamoya vessels extending all over the cerebral hemisphere; those vessels were less prominent in the ordinary angiograms. The vascular networks of the arteriovenous malformation, which were not evident in the ordinary angiograms, were also revealed by the CT-AG. For the patient with poor prospects, CT-AG will be were valid as a screening study than ordinary angiography because of its less invasive procedure using a small amount of the contrast substance. CT-AG on a dynamic scan mode possible optimal timing in the visualization of the

  2. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: prospective, multicentre cohort study

    OpenAIRE

    van Asch, Charlotte J. J.; Birgitta K Velthuis; Rinkel, Gabriël J E; Algra, Ale; de Kort, Gerard A. P.; Witkamp, Theo D.; de Ridder, Johanna C M; van Nieuwenhuizen, Koen M.; De Leeuw, Frank Erik; Schonewille, Wouter J.; de Kort, Paul L. M.; Dippel, Diederik W; Raaymakers, Theodora W M; Hofmeijer, Jeannette; Wermer, Marieke J. H.

    2015-01-01

    Study question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This prospective diagnostic study enrolled 298 adults (18-70 years) treated in 22 hospitals in the Netherlands over six years. CT angiography was performed within seven days of haemorrhage. If the result was negative, MRI/MR...

  3. CT Pulmonary Angiography and Suspected Acute Pulmonary Embolism

    Energy Technology Data Exchange (ETDEWEB)

    Enden, T.; Kloew, N.E. [Ullevaal Univ. Hospital, Oslo (Norway). Dept. of Cardiovascular Radiology

    2003-05-01

    Purpose: To evaluate the use and quality of CT pulmonary angiography in our department, and to relate the findings to clinical parameters and diagnoses. Material and Methods: A retrospective study of 324 consecutive patients referred to CT pulmonary angiography with clinically suspected pulmonary embolism (PE). From the medical records we registered clinical parameters, blood gases, D-dimer, risk factors and the results of other relevant imaging studies. Results: 55 patients (17%) had PE detected on CT. 39 had bilateral PE, and 8 patients had isolated peripheral PE. 87% of the examinations showing PE had satisfactory filling of contrast material including the segmental pulmonary arteries, and 60% of the subsegmental arteries. D-dimer test was performed in 209 patients, 85% were positive. A negative D-dimer ruled out PE detected at CT. Dyspnea and concurrent symptoms or detection of deep vein thrombosis (DVT), contraceptive pills and former venous thromboembolism (VTE) were associated with PE. The presence of only one clinical parameter indicated a negative PE diagnosis (p < 0.017), whereas two or more suggested a positive PE diagnosis (p < 0.002). CT also detected various ancillary findings such as consolidation, pleural effusion, nodule or tumor in nearly half of the patients; however, there was no association with the PE diagnosis. Conclusion: The quality of CT pulmonary angiography was satisfactory as a first-line imaging of PE. CT also showed additional pathology of importance in the chest. Our study confirmed that a negative D-dimer ruled out clinically suspected VTE.

  4. Time-resolved CT angiography in aortic dissection

    Energy Technology Data Exchange (ETDEWEB)

    Meinel, Felix G., E-mail: felix.meinel@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Nikolaou, Konstantin, E-mail: konstantin.nikolaou@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Weidenhagen, Rolf, E-mail: rolf.weidenhagen@med.uni-muenchen.de [Department of Surgery, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Hellbach, Katharina, E-mail: katharina.hellbach@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Helck, Andreas, E-mail: andreas.helck@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Bamberg, Fabian, E-mail: fabian.bamberg@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Reiser, Maximilian F., E-mail: maximilian.reiser@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany); Sommer, Wieland H., E-mail: wieland.sommer@med.uni-muenchen.de [Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany)

    2012-11-15

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 {+-} 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 {+-} 3.5 mSv. CT density of the true lumen peaked at 355 {+-} 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  5. Acute gastrointestinal bleeding: CT angiography with multi-planar reformatting.

    Science.gov (United States)

    Steiner, Kate; Gollub, Frank; Stuart, Sam; Papadopoulou, Anthie; Woodward, Nick

    2011-04-01

    Acute gastrointestinal bleeding is a common medical emergency, which carries a significant mortality. CT Angiography is an important non-invasive diagnostic tool, which can be used to plan subsequent endovascular or surgical management. The cases presented demonstrate that a meticulous and systematic approach to image interpretation is necessary, in particular, to detect focal sites of contrast extravasation and small pseudoaneurysms.

  6. Reconstructions with identical filling (RIF) of the heart: a physiological approach to image reconstruction in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Reinartz, S.D.; Diefenbach, B.S.; Kuhl, C.K.; Mahnken, A.H. [University Hospital, RWTH Aachen University, Department of Diagnostic and Interventional Radiology, Aachen (Germany); Allmendinger, T. [Siemens Healthcare Sector, Department of Computed Tomography, Forchheim (Germany)

    2012-12-15

    To compare image quality in coronary artery computed tomography angiography (cCTA) using reconstructions with automated phase detection and Reconstructions computed with Identical Filling of the heart (RIF). Seventy-four patients underwent ECG-gated dual source CT (DSCT) between November 2009 and July 2010 for suspected coronary heart disease (n = 35), planning of transcatheter aortic valve replacement (n = 34) or evaluation of ventricular function (n = 5). Image data sets by the RIF formula and automated phase detection were computed and evaluated with the AHA 15-segment model and a 5-grade Likert scale (1: poor, 5: excellent quality). Subgroups regarding rhythm (sinus rhythm = SR; arrhythmia = ARR) and potential premedication were evaluated by a per-segment, per-vessel and per-patient analysis. RIF significantly improved image quality in 10 of 15 coronary segments (P < 0.05). More diagnostic segments were provided by RIF regarding the entire cohort (n = 693 vs. 590, P < 0.001) and all of the subgroups (e.g. ARR: n = 143 vs. 72, P < 0.001). In arrhythmic patients (n = 19), more diagnostic vessels (e.g. LAD: n = 10 vs. 3; P < 0.014) and complete data sets (n = 7 vs. 1; P < 0.001) were produced. RIF reconstruction is superior to automatic diastolic non-edited reconstructions, especially in arrhythmic patients. RIF theory provides a physiological approach for determining the optimal image reconstruction point in ECG-gated CT angiography. (orig.)

  7. Usefulness of 3D-CT angiography using multislice CT for diagnosing cardiovascular anomalies in infants

    Energy Technology Data Exchange (ETDEWEB)

    Kani, Hiroyuki; Matsuki, Mitsuru; Masuda, Kiyohiro; Narabayashi, Isamu; Katayama, Hiroshi; Mori, Yasuhiko; Tamai, Hiroshi [Osaka Medical Coll., Takatsuki (Japan)

    2003-05-01

    We compared three-dimensional computed tomographic angiography using multislice CT (3D-CTA) with echocardiography and angiography in terms of usefulness in the diagnosis of 13 infants with cardiovascular anomalies. 3D-CTA clearly depicted stenoses of the pulmonary artery and vein, and coarctation of the aorta in some cases, which could not be revealed by echocardiography and angiography. Moreover, it provided objectively more information on vascular morphologic characteristics and 3D anatomic relations than echocardiography and angiography. 3D-CTA is a noninvasive and convenient diagnostic technique for cardiovascular anomalies in infants. (author)

  8. Noninvasive Physiologic Assessment of Coronary Stenoses Using Cardiac CT

    Directory of Open Access Journals (Sweden)

    Lei Xu

    2015-01-01

    Full Text Available Coronary CT angiography (CCTA has become an important noninvasive imaging modality in the diagnosis of coronary artery disease (CAD. CCTA enables accurate evaluation of coronary artery stenosis. However, CCTA provides limited information on the physiological significance of stenotic lesions. A noninvasive “one-stop-shop” diagnostic test that can provide both anatomical significance and functional significance of stenotic lesions would be beneficial in the diagnosis and management of CAD. Recently, with the introduction of novel techniques, such as myocardial CT perfusion, CT-derived fractional flow reserve (FFRCT, and transluminal attenuation gradient (TAG, CCTA has emerged as a noninvasive method for the assessment of both anatomy of coronary lesions and its physiological consequences during a single study. This review provides an overview of the current status of new CT techniques for the physiologic assessments of CAD.

  9. Usefulness of CT angiography in diagnosing acute gastrointestinal bleeding:A meta-analysis

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    AIM: To analyze the accuracy of computed tomography (CT) angiography in the diagnosis of acute gastrointestinal (GI) bleeding. METHODS: The MEDLINE, EMBASE, Cancerlit, Cochrane Library database, Sciencedirect, Springerlink and Scopus, from January 1995 to December 2009, were searched for studies evaluating the accuracy of CT angiography in diagnosing acute GI bleeding. Studies were included if the ycompared CT angiography to a reference standard of upper GI endoscopy, colonoscopy, angiography or surgery in ...

  10. Transluminal attenuation gradient in coronary computed tomography angiography for determining stenosis severity of calcified coronary artery: a primary study with dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen; Wei, Mengqi; Wen, Didi; Zhao, Hongliang; Liu, Ying; Li, Jian [Fourth Military Medical University, Department of Radiology, Xijing Hospital, Xi' an, Shaanxi Province (China); Li, Jiayi [Fourth Military Medical University, Department of Cardiology, Xijing Hospital, Xi' an, Shaanxi Province (China)

    2015-05-01

    To evaluate the diagnostic accuracy of transluminal attenuation gradient (TAG) for stenosis severity of calcified lesions assessed by coronary computed tomography angiography (CCTA). One hundred seven patients who underwent CCTA and coronary angiography (CAG) were enrolled. TAGs of 309 major epicardial coronary arteries were measured. The impact of plaque composition, Agatston scores, and lesion length ratio on TAG were analyzed. Diagnostic performance vs. CAG of TAG, CCTA, and combined TAG/CCTA were evaluated, and incremental value of TAG for reclassification of CCTA stenosis severity in calcified lesions was also analyzed. TAG decreased consistently with stenosis severity. TAG was significantly lower in coronary arteries with calcification scores >300 and lesion length ratios >2/3. TAG improved diagnostic accuracy of CCTA (c-statistic =0.982 vs. 0.942, P = 0.0001) in calcified lesions, and the sensitivity, specificity, positive, and negative predictive values of TAG cutoff ≤ -11.33 were 72 %, 91 %, 88 %, and 78 %, respectively. The addition of TAG to CCTA resulted in significant reclassification (NRI =0.093, P = 0.022) in calcified vessels. Measurement of TAG may improve diagnostic performance and reclassification of CCTA in coronary stenosis caused by calcified lesions. (orig.)

  11. [CT coronary angiography: indications, image acquisition, and interpretation].

    Science.gov (United States)

    Schoepf, U J; Thilo, C; Fernández, M J; Costello, P

    2008-01-01

    Intense scientific and clinical evaluation have brought about great improvements in cardiac CT. This is no longer merely an experimental technique, rather it has become a clinical application that is ready to fulfill its promise of replacing invasive cardiac catheterization in certain patient populations. Among the proven indications is the evaluation of patients with atypical chest pain, the morphological evaluation of the coronary arteries in cases of suspected congenital anomalies, and before surgical intervention, as well as the evaluation of coronary revascularizations. The use of CT angiography for the exhaustive evaluation of cardiac and non-cardiac pathology in patients with acute chest pain in the emergency department is currently being investigated. Because the heart is continuously moving, CT coronary angiography represents a greater technical challenge than other applications of CT. On the other hand, rapid technical development requires acquisition protocols to be adjusted constantly. However, users that know the general techniques of computed tomography can overcome these challenges. The aim of this article is to provide those interested and involved in CT angiography with a manual to enable them to follow our method step by step. We include considerations regarding the correct selection of patients, patient medication, radiological protection, contrast enhancement, acquisition and reconstruction parameters, image display, image analysis techniques, and the radiological report. Our recommendations are based on our experience, which runs from the evolution of multiple-row detector CT scanners for cardiac applications from its beginnings to the most modern presentations of advanced acquisition modalities, including dual-source CT, which we consider to be the precursor of this test in routine clinical practice.

  12. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    Energy Technology Data Exchange (ETDEWEB)

    Hyare, Harpreet [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom)]. E-mail: hhyare@doctors.org.uk; Desigan, Sharmini [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom); Nicholl, Helen [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom); Guiney, Michael J. [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom); Brookes, Jocelyn A. [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom); Lees, William R. [Department of Imaging, University College London Hospitals NHS Foundation Trust, University College Hospital, 235 Euston Road, London NW1 2BU (United Kingdom)

    2006-08-15

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients.

  13. Noninvasive detection of vertebral artery stenosis: a comparison of contrast-enhanced MR angiography, CT angiography, and ultrasound.

    Science.gov (United States)

    Khan, Sofia; Rich, Philip; Clifton, Andrew; Markus, Hugh S

    2009-11-01

    Vertebral stenosis is associated with a high risk of recurrent stroke, but noninvasive imaging techniques to identify it have lacked sensitivity. Contrast-enhanced MR angiography and CT angiography have been recently developed and appear to have better sensitivity. However, no prospective studies have compared both of these techniques with ultrasound against the gold standard of intra-arterial angiography in the same group of patients. Forty-six patients were prospectively recruited in whom intra-arterial angiography was being performed. Contrast-enhanced MR angiography, CT angiography, and duplex ultrasound were also performed. Angiographic images were analyzed blinded to patient identity by 2 experienced neuroradiologists. Contrast-enhanced MR angiography had the highest sensitivity and specificity (Radiologist 1, 0.83 and 0.91, respectively; Radiologist 2, 0.89 and 0.87) for detecting >or=50% stenosis. CT angiography had good sensitivity (Radiologist 1, 0.68; Radiologist 2, 0.58) and excellent specificity (Radiologist 1, 0.92; Radiologist 2, 0.93), whereas duplex had low sensitivity (0.44) but excellent specificity (0.95). For vertebral origin stenosis >or=50%, sensitivities were similar for contrast-enhanced MR angiography (Radiologist 1, 0.91; Radiologist 2, 0.82) but relatively higher for CT angiography (Radiologist 1, 0.82; Radiologist 2, 0.82) and duplex (0.67). Contrast-enhanced MR angiography is the most sensitive noninvasive technique to detect vertebral artery stenosis and also has high specificity. CT angiography has good sensitivity and high specificity. In contrast, ultrasound has low sensitivity and will miss many vertebral stenoses.

  14. Coronary CT angiography-derived quantitative markers for predicting in-stent restenosis

    NARCIS (Netherlands)

    Tesche, Christian; De Cecco, Carlo N.; Vliegenthart, Rozemarijn; Duguay, Taylor M.; Stubenrauch, Andrew C.; Rosenberg, Russell D.; Varga-Szemes, Akos; Bayer, Richard R.; Yang, Junjie; Ebersberger, Ullrich; Baguet, Moritz; Jochheim, David; Hoffmann, Ellen; Steinberg, Daniel H.; Chiaramida, Salvatore A.; Schoepf, U. Joseph

    2016-01-01

    Objective: To evaluate quantitative markers derived from coronary CT angiography (coronary CTA) performed prior to percutaneous coronary intervention (PCI) with stent placement for predicting in-stent restenosis (ISR) as defined by quantitative coronary angiography (QCA). Materials and methods: We

  15. Prospective ECG-triggered coronary CT angiography: clinical value of noise-based tube current reduction method with iterative reconstruction.

    Directory of Open Access Journals (Sweden)

    Junlin Shen

    Full Text Available OBJECTIVES: To evaluate the clinical value of noise-based tube current reduction method with iterative reconstruction for obtaining consistent image quality with dose optimization in prospective electrocardiogram (ECG-triggered coronary CT angiography (CCTA. MATERIALS AND METHODS: We performed a prospective randomized study evaluating 338 patients undergoing CCTA with prospective ECG-triggering. Patients were randomly assigned to fixed tube current with filtered back projection (Group 1, n = 113, noise-based tube current with filtered back projection (Group 2, n = 109 or with iterative reconstruction (Group 3, n = 116. Tube voltage was fixed at 120 kV. Qualitative image quality was rated on a 5-point scale (1 = impaired, to 5 = excellent, with 3-5 defined as diagnostic. Image noise and signal intensity were measured; signal-to-noise ratio was calculated; radiation dose parameters were recorded. Statistical analyses included one-way analysis of variance, chi-square test, Kruskal-Wallis test and multivariable linear regression. RESULTS: Image noise was maintained at the target value of 35HU with small interquartile range for Group 2 (35.00-35.03HU and Group 3 (34.99-35.02HU, while from 28.73 to 37.87HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 20% and 51% reduction in effective dose for Group 2 (2.9 mSv and Group 3 (1.8 mSv were achieved compared with Group 1 (3.7 mSv. After adjustment for scan characteristics, iterative reconstruction was associated with 26% reduction in effective dose. CONCLUSION: Noise-based tube current reduction method with iterative reconstruction maintains image noise precisely at the desired level and achieves consistent image quality. Meanwhile, effective dose can be reduced by more than 50%.

  16. 3D-CT angiography. Intracranial arterial lesions

    Energy Technology Data Exchange (ETDEWEB)

    Asato, Mikio; Tong, X.Q.; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan)] [and others

    1997-06-01

    Since its introduction, three dimensional CT angiography (3D-CTA) on spiral (helical) CT has played an important role in clinical imaging. Initially it was reported to be useful in depicting aortic abnormalities, afterwards the merit in detecting intracranial aneurysm by 3D-CTA was also described. We have investigated the usefullness of 3D-CTA in detecting patients of intracranial aneurysm as well as arterio-venous malformation (AVM), Moyamoya disease and stenosis of middle cerebral artery, meanwhile the MR angiography (MRA) and digital subtraction angiography (DSA) examination of these patients were also studied as comparison to the 3D-CTA results. The sensitivity and specificity on investigating intracranial aneurysm were similar with other reports so far. 3D-CTA was possible to identify the feeding artery, nidus and draining vein of AVM, although DSA showed higher detectability. Occlusion of internal carotid artery and post-operative anastomosis in Moyamoya disease were all demonstrated by 3D-CTA, however the Moyamoya collaterals were shown better on MRA. 3D-CTA revealed the site of stenosis of middle cerebral artery in all of our cases, but in general maximum intensity projection (MIP) images can provide more exact information about the degree of stenosis. Five years has passed since the emergence of spiral CT and utilizing of 3D-CTA in clinical applications. With the development of hard and soft ware in the near future, it is possible to delineate more small vessels by 3D-CTA. We predict that 3D-CTA would be widely used for detecting vasculature of the whole body, and may take the place of conventional angiography in many cases. (author)

  17. Patient satisfaction with coronary CT angiography, myocardial CT perfusion, myocardial perfusion MRI, SPECT myocardial perfusion imaging and conventional coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Feger, S.; Rief, M.; Zimmermann, E.; Richter, F.; Roehle, R. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Dewey, M. [Freie Universitaet Berlin, Department of Radiology, Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Berlin (Germany); Institut fuer Radiologie, Berlin (Germany); Schoenenberger, E. [Medizinische Hochschule Hannover, Department of Medicine, Hannover (Germany)

    2015-07-15

    To evaluate patient acceptance of noninvasive imaging tests for detection of coronary artery disease (CAD), including single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI), stress perfusion magnetic resonance imaging (MRI), coronary CT angiography (CTA) in combination with CT myocardial stress perfusion (CTP), and conventional coronary angiography (CCA). Intraindividual comparison of perception of 48 patients from the CORE320 multicentre multinational study who underwent rest and stress SPECT-MPI with a technetium-based tracer, combined CTA and CTP (both with contrast agent, CTP with adenosine), MRI, and CCA. The analysis was performed by using a validated questionnaire. Patients had significantly more concern prior to CCA than before CTA/CTP (p < 0.001). CTA/CTP was also rated as more comfortable than SPECT-MPI (p = 0.001). Overall satisfaction with CT was superior to that of MRI (p = 0.007). More patients preferred CT (46 %; p < 0.001) as a future diagnostic test. Regarding combined CTA/CTP, CTP was characterised by higher pain levels and an increased frequency of angina pectoris during the examination (p < 0.001). Subgroup analysis showed a higher degree of pain during SPECT-MPI with adenosine stress compared to physical exercise (p = 0.016). All noninvasive cardiac imaging tests are well accepted by patients, with CT being the preferred examination. (orig.)

  18. Dynamic CT head phantom for perfusion and angiography studies

    Science.gov (United States)

    Russell, K.; Blazeski, A.; Dannecker, K.; Lee, Q. Y.; Holscher, C.; Donahue, C.; van Kampen, W.

    2010-03-01

    Contrast imaging is a compelling enhancement for the portable, flat panel-based brain CT scanner currently under development at Xoran. Due to the relative low temporal resolution of flat panel detectors, enabling tomographic imaging on such platform requires optimizing the imaging and injection protocols. A dynamic CT head phantom was designed to facilitate this task. The Dynamic Perfusion and Angiography Model (PAM), mimics tissue attenuation in CT images, provides physiological timing for angiography and perfusion studies, and moves fluid with properties similar to those of blood. The design consists of an arterial system, which contains bifurcating vessels that feed into perfusion chambers, mimicking blood flow through capillaries and smaller vessels, and a venous system, which is symmetrical to the arterial side and drains the perfusion chambers. The variation of geometry and flow rate in the phantom provides the physiological total time that fluid spends in the head, and the difference in material densities correlates to CT numbers for biological tissues. This paper discusses the design of Dynamic PAM and shows experimental results demonstrating its ability to realistically simulate blood flow. Results of dynamic imaging studies of the phantom are also presented.

  19. Image Quality and Radiation Exposure in Coronary CT Angiography According to Tube Voltage and Body Mass Index

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Kyung [Korea University Guro Hospital, Seoul (Korea, Republic of); Kim, Yoo Kyung [Ewha Womans University MokDong Hospital, Seoul (Korea, Republic of)

    2010-01-15

    To investigate the image quality and radiation dose of a coronary CT angiography (CCTA) according to tube voltage and body mass index (BMI). This study included 139 patients who underwent CCTA using a retrospective electrocardiography- gating technique. A total of 48 patients (BMI <2 5, group A) were examined with 100 kVp, 45 patients (BMI > 25, group B) with 120 kVp, and 46 patients (BMI < 25, group C) with 120 kVp. Attenuation and image noise of the aorta and coronary arteries was measured. Moreover, the image quality of 9 coronary segments was graded on a scale of 1-5, where grade 4 or 5 was considered to be diagnostic. Image quality parameters and radiation dose were compared using a t-test or Chi-squared test. Results: Vessel attenuation in group A was significantly higher than in groups B or C (group A, 592 {+-} 85 HU; group B, 437 {+-} 46 HU; group C, 469 {+-} 62 HU, p<0.001). Image noise was similar in group A and group B (23 {+-} 5 HU versus 22 {+-} 6 HU, p=0.427), but significantly higher in group A compared to group C (23 {+-} 5 HU versus 17 {+-} 4 HU, p<0.001). A significant difference was observed in the signal-to-noise ratio between the three groups (group A, 24 {+-} 6; group B, 19 {+-} 3; group C, 27 {+-} 5: p<0.05). Moreover, the contrast-to-noise ratio was significantly higher in group A than group B (group A 18 {+-} 5 versus group B 14 {+-} 3, p < 0.001) but not significantly different between group A and group C (group C 20 {+-} 4, p=0.127). The percentage of coronary segments with diagnostic image quality was 97.9% in group A, 96.0% in group B, and 99.0% in group C. The mean image quality score was 4.5 {+-} 0.5 in group A, 4.1 {+-} 0.4 in group B, and 4.2 {+-} 0,4 in group C (p<0.001). The effective radiation doses were 8.5 {+-} 0.8 mSv in group A, 14.3 {+-} 1.3 mSv in group B, and 14.9 {+-} 1.3 mSv in group C. A 42% reduction in mean effective radiation dose in group A was observed compared with groups B and C. In patients with BMI less than 25

  20. Relation of aortic calcification, wall thickness, and distensibility with severity of coronary artery disease: evaluation with coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Seonah; Yong, Hwan Seok; Doo, Kyung Won; Kang, Eun-Young; Woo, Ok Hee; Choi, Eun Jung [Dept. of Radiology, Korea Univ. Guro Hospital, Korea Univ. College of Medicine, Seoul (Korea, Republic of)], e-mail: yhwanseok@naver.com

    2012-10-15

    Background Three known risk factors for aortic atherosclerosis predict the severity of coronary artery disease (CAD): aortic calcification (AC), aortic wall thickness (AWT), and aortic distensibility (AD). Purpose To determine the relationship of AC, AWT, and AD with the severity of CAD. Material and Methods A total of 104 patients who underwent both coronary CT angiography (CCTA) and invasive coronary angiography were enrolled. The severity of CAD was assessed by three methods: the segment involvement score (SIS), the segment stenosis score (SSS), and the modified Gensini score (mG). We quantified AC using the Agatston method on low-dose ungated chest CT (LDCT). We measured AWT at the thickest portion of the descending thoracic aorta on CCTA. AD was calculated as the difference between the maximum and minimum areas of the ascending aorta and the pulse pressure. The relationships between the severity of CAD and the three aortic factors were assessed. Results The AC and AWT of the thoracic aorta were significantly higher in the occlusive CAD (OCAD) group (1984.21 {+-} 2986.10 vs. 733.00 {+-} 1648.71, P = 0.01; 4.13 {+-} 1.48 vs. 3.40 {+-} 1.01, P = 0.22). Patients with OCAD had more than one epicardial coronary artery with >50% luminal stenosis. The AC (r = 0.453 with SIS; r = 0.454 with SSS; r = 0.427 with mG) and the AWT (r = 0.279 with SIS; r = 0.324 with SSS; r = 0.304 with mG) were significantly correlated with all three methods, and the AD was negatively correlated with the SIS (r = - 0.221, P < 0.05, respectively) in the unadjusted model. After adjustment for cardiovascular risk factors, only the correlations between AC and all three methods assessing CAD remained significant. Conclusion There are significant relationships between AC, AWT and AD and severity of CAD. In particular, AC measured on LDCT is the most consistent predictor of severity of CAD.

  1. Intravenous Contrast Material Administration at High-pitch Dual-source CT Coronary Angiography: Bolus-tracking Technique with Shortened Time of Respiratory Instruction Versus Test Bolus Technique

    Institute of Scientific and Technical Information of China (English)

    Kai Sun; Guo-rong Liu; Yue-chun Li; Rui-juan Han; Li-fang Cui; Li-jun Ma; Li-gang Li; Chang-yong Li

    2012-01-01

    Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique.Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study.The patients were randomly divided into two groups.Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode),while those in the group B (n=92) underwent CCTA with test bolus technique.The attenuation in the ascending aorta,image noise,contrast-to-noise ratio and radiation doses of the two groups were assessed.Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs.498.7±83.51 HU,P=0.183),image noise (21.4±4.5 HU vs.20.9±4.3 HU,P=0.414),contrast-to-noise ratio (12.1±4.2 vs.13.8±5.1,P=0.31) between the groups A and B.There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs.0.062±0.018 mSv,P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs.0.96±0.15 mSv,P=0.926) between the two groups,while 15 mL less contrast material volume was administered in the group A than the group B.Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.

  2. CT angiography in patients with spontaneous intracerebral hematoma

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Dae Young; Shim, Joo Eun; Yi, Jeong Geun; Kim, Ho Chul; Choi, Chul Soon; Bae, Sang Hoon [Hallym University College of Medicine, Choonchun (Korea, Republic of)

    1998-01-01

    The purpose of this study was to assess the usefulness of CT angiography (CTA) in patients with intracerebral hematoma. Eighteen patients with spontaneous intracerebral hematoma underwent CTA; 20-30 seconds after the onset of an injection of contrast media (100mL), with the use of a power injector, at a rate of 3mL/sec, scanning (30-second continuous exposure and 60-90mm length) was performed with a table speed of 2-3 mm/sec and section thickness of 2mm. The starting point selected was the floor of the sella turcica. The resulting data were reformatted by maximum intensity projection (MIP) after reconstruction at 1-mm intervals, and CTA findings were compared with those of conventional angiography (n=17), surgery (n=6), and postcontrast CT(n=10). The diagnostic findings of CTA included five arteriovenous malformations, two aneurysms, one venous angioma, and one venous sinus occlusion, while the remaining nine patients had no vascular lesion. In all cases, CTA findings correlated well with those of postcontrast CT. In one cases of arteriovenous malformation, however, the feeding artery and draining vein were not definite on CTA, and in one case of sinus occlusion, the full length of the superior sagittal sinus could not be delineated. In patients with spontaneous intracerebral hematoma, CTA is a valuable screening method. (author). 15 refs., 4 figs.

  3. Comparing Measurements of CT Angiography, TEE, and Fluoroscopy of the Left Atrial Appendage for Percutaneous Closure.

    Science.gov (United States)

    Saw, Jacqueline; Fahmy, Peter; Spencer, Ryan; Prakash, Roshan; McLaughlin, Patrick; Nicolaou, Savvas; Tsang, Michael

    2016-04-01

    Left atrial appendage (LAA) closure requires accurate preprocedural measurements, and trans-esophageal echocardiography (TEE), cardiac computed tomography angiography (CCTA) and fluoroscopy can be utilized. However, correlations between these measurements remain inadequately assessed. Patients who underwent LAA closure at Vancouver General Hospital who had baseline LAA measurements by CCTA, TEE, and fluoroscopy were included in this analysis. CCTAs were performed with prospective-ECG-gating with Toshiba 320-detector or Siemens second generation 128-slice dual-source scanners, and images interpreted with VitreaWorkstation.™ LAA maximal dimensions were obtained for all patients at: (1) Amplatzer Cardiac Plug (ACP)/Amulet landing zone 10 mm within orifice, (2) WATCHMAN ostium, and (3) WATCHMAN depth measurements. Correlations and agreements were compared. We report 50 consecutive patients who underwent LAA closure (8 ACP, 10 Amulet, 32 WATCHMAN). Average age was 75.2 ± 8.7 years, mean CHADS2 score 3.0 ± 1.3, and CHA2 DS2 -VASc 4.7 ± 1.5. Procedural device implantation success was 100%. For ACP landing zone, mean maximal measurements were 24.1 ± 4.7 mm with CCTA, 22.3 ± 4.9 mm TEE, and 19.9 ± 5.6 mm fluoroscopy (P < 0.001); R value 0.81 fluoroscopy/CTA, 0.67 fluoroscopy/TEE, and 0.80 CTA/TEE. For WATCHMAN ostium, mean maximal measurements were 25.8 ± 4.7 mm CCTA (P < 0.001 vs. fluoroscopy, P = 0.16 vs. TEE), 25.1 ± 4.4 mm TEE (P = 0.016 vs. fluoroscopy), and 23.8 ± 4.9 mm fluoroscopy; R value 0.71 fluoroscopy/CTA, 0.65 fluoroscopy/TEE, and 0.74 CTA/TEE. Depth measurements were 34.3 ± 5.7 mm with CCTA, 31.1 ± 6.5 mm TEE, and 27.8 ± 7.1 mm fluoroscopy (all P < 0.01); and correlations with R value 0.28 fluoroscopy/CTA, 0.22 fluoroscopy/TEE, and 0.56 CTA/TEE. All 3 imaging modalities correlated with ACP landing zone and WATCHMAN ostium measurements, with CCTA providing the largest measurements, followed by TEE and fluoroscopy. © 2016 Wiley Periodicals, Inc.

  4. Accuracy of coronary plaque detection and assessment of interobserver agreement for plaque quantification using automatic coronary plaque analysis software on coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Laqmani, A.; Quitzke, M.; Creder, D.D.; Adam, G.; Lund, G. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology and Nuclearmedicine; Klink, T. [Wuerzburg Univ. (Germany). Inst. of Diagnostic and Interventional Radiology

    2016-10-15

    To evaluate the accuracy of automatic plaque detection and the interobserver agreement of automatic versus manually adjusted quantification of coronary plaques on coronary CT angiography (cCTA) using commercially available software. 10 cCTA datasets were evaluated using plaque software. First, the automatically detected plaques were verified. Second, two observers independently performed plaque quantification without revising the automatically constructed plaque contours (automatic approach). Then, each observer adjusted the plaque contours according to plaque delineation (adjusted approach). The interobserver agreement of both approaches was analyzed. 32 of 114 automatically identified findings were true-positive plaques, while 82 (72 %) were false-positive. 20 of 52 plaques (38 %) were missed by the software (false-negative). The automatic approach provided good interobserver agreement with relative differences of 0.9 ± 16.0 % for plaque area and -3.3 ± 33.8 % for plaque volume. Both observers independently adjusted all contours because they did not represent the plaque delineation. Interobserver agreement decreased for the adjusted approach with relative differences of 25.0 ± 24.8 % for plaque area and 20.0 ± 40.4 % for plaque volume. The automatic plaque analysis software is of limited value due to high numbers of false-positive and false-negative plaque findings. The automatic approach was reproducible but it necessitated adjustment of all constructed plaque contours resulting in deterioration of the interobserver agreement.

  5. Marketing cardiac CT programs.

    Science.gov (United States)

    Scott, Jason

    2010-01-01

    There are two components of cardiac CT discussed in this article: coronary artery calcium scoring (CACS) and coronary computed tomography angiography (CCTA).The distinctive advantages of each CT examination are outlined. In order to ensure a successful cardiac CT program, it is imperative that imaging facilities market their cardiac CT practices effectively in order to gain a competitive advantage in this valuable market share. If patients receive quality care by competent individuals, they are more likely to recommend the facility's cardiac CT program. Satisfied patients will also be more willing to come back for any further testing.

  6. Multidetector CT angiography for acute gastrointestinal bleeding: technique and findings.

    Science.gov (United States)

    Artigas, José M; Martí, Milagros; Soto, Jorge A; Esteban, Helena; Pinilla, Inmaculada; Guillén, Eugenia

    2013-01-01

    Acute gastrointestinal bleeding is a common reason for emergency department admissions and an important cause of morbidity and mortality. Factors that complicate its clinical management include patient debility due to comorbidities; intermittence of hemorrhage; and multiple sites of simultaneous bleeding. Its management, therefore, must be multidisciplinary and include emergency physicians, gastroenterologists, and surgeons, as well as radiologists for diagnostic imaging and interventional therapy. Upper gastrointestinal tract bleeding is usually managed endoscopically, with radiologic intervention reserved as an alternative to be used if endoscopic therapy fails. Endoscopy is often less successful in the management of acute lower gastrointestinal tract bleeding, where colonoscopy may be more effective. The merits of performing bowel cleansing before colonoscopy in such cases might be offset by the resultant increase in response time and should be weighed carefully against the deficits in visualization and diagnostic accuracy that would result from performing colonoscopy without bowel preparation. In recent years, multidetector computed tomographic (CT) angiography has gained acceptance as a first-line option for the diagnosis and management of lower gastrointestinal tract bleeding. In selected cases of upper gastrointestinal tract bleeding, CT angiography also provides accurate information about the presence or absence of active bleeding, its source, and its cause. This information helps shorten the total diagnostic time and minimizes or eliminates the need for more expensive and more invasive procedures.

  7. Current but not past smoking increases the risk of cardiac events: Insights from coronary computed tomographic angiography

    NARCIS (Netherlands)

    R. Nakanishi (Rine); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); H. Gransar (Heidi); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); V.Y. Cheng (Victor Y.); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee J.); T.C. Villines (Todd); A. Dunning (Allison); J.K. Min (James)

    2015-01-01

    textabstractAims We evaluated coronary artery disease (CAD) extent, severity, and major adverse cardiac events (MACEs) in never, past, and current smokers undergoing coronary CT angiography (CCTA). Methods and results We evaluated 9456 patients (57.1 ± 12.3 years, 55.5% male) without known CAD (1588

  8. Current but not past smoking increases the risk of cardiac events: Insights from coronary computed tomographic angiography

    NARCIS (Netherlands)

    R. Nakanishi (Rine); D.S. Berman (Daniel); M.J. Budoff (Matthew J.); H. Gransar (Heidi); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); V.Y. Cheng (Victor Y.); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); M. Hadamitzky (Martin); J. Hausleiter (Jörg); G.M. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); P.A. Kaufmann (Philipp A.); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee J.); T.C. Villines (Todd); A. Dunning (Allison); J.K. Min (James)

    2015-01-01

    textabstractAims We evaluated coronary artery disease (CAD) extent, severity, and major adverse cardiac events (MACEs) in never, past, and current smokers undergoing coronary CT angiography (CCTA). Methods and results We evaluated 9456 patients (57.1 ± 12.3 years, 55.5% male) without known CAD (1588

  9. Radiation dose in cerebral angiography and flat detector CT applications in neuroradiology; Strahlendosis bei zerebraler Angiographie und Flachdetektor-CT-Applikationen in der Neuroradiologie

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, T.; Lang, S.; Doerfler, A. [Universitaetsklinikum Erlangen, Friedrich-Alexander-Universitaet Erlangen-Nuernberg, Abteilung fuer Neuroradiologie, Erlangen (Germany); Scholz, R. [Siemens Healthcare GmbH, Forchheim (Germany); Hauer, M. [Klinikum Nuernberg Sued, Institut fuer Radiologie und Neuroradiologie, Nuernberg (Germany)

    2015-08-15

    Flat detectors (FD) have completely replaced image intensifiers in angiography. Due to this development not only the image quality of 2D digital subtraction angiography series (2-D-DSA) could be improved but also the acquisition of computed tomography (CT)-like cross-sectional images (FD-CT) within the angio suite became feasible. These techniques are now being used in daily clinical routine. Only little information about effective doses of these applications to patients has been published in the literature. We describe the effective patient dose of current applications in the field of angiography and demonstrate strategies to minimize the dose to the patient. In addition, we compare FD-CT applications to standard multislice CT applications. (orig.) [German] Flachdetektoren haben Bildverstaerker in der Angiographie vollstaendig abgeloest. Mit dieser Entwicklung verbesserte sich nicht nur die Bildqualitaet subtrahierter 2-D-Angiographieserien (2-D-DSA), sondern auch die Akquisition CT-aehnlicher Schnittbilder (FD-CT) mit unterschiedlichen Indikationen wurde moeglich. Diese Techniken werden nun in der taeglichen klinischen Routine eingesetzt. Angaben zur effektiven Patientendosis dieser Applikationen sind bis jetzt in der Literatur nur wenige publiziert worden. Wir beschreiben die effektive Patientendosis aktueller Anwendungen im Bereich der Angiographie und zeigen Strategien zur Minimierung der Dosis fuer den Patienten auf. Zudem vergleichen wir FD-CT-Applikationen mit Standard-Multislice-CT-Anwendungen. (orig.)

  10. Cardiac CT angiography after coronary artery surgery in children using 64-slice CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Marini, Davide; Agnoletti, Gabriella [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); Brunelle, Francis [University Paris Descartes, UFR Necker-Enfants Malades, Department of Pediatric Radiology, APHP, Paris (France); Sidi, Daniel; Bonnet, Damien [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); Ou, Phalla [Centre de Reference Malformations Cardiaques Congenitales Complexes-M3C, Universite Paris Descartes, UFR Necker-Enfants Malades, Paris (France); University Paris Descartes, UFR Necker-Enfants Malades, Department of Pediatric Radiology, APHP, Paris (France)], E-mail: phalla.ou@nck.aphp.fr

    2009-09-15

    Objective: The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. Population and methods: Fifteen consecutive children (8 male and 7 female; age 9.2 {+-} 6.1 years) underwent 64-slice CT because of chest pain or ECG changes mean 4.8 {+-} 3.7 years after surgical coronary artery surgery; 10 patients had coronary angioplasty using a patch from the saphenous vein, four had mammary artery bypass, and one had saphenous vein bypass. Six main segments of the coronary arteries and all the bypass graft considered as a single segment were analyzed and compared with invasive angiography used as the reference standard. Results: CT correctly identified the four children with coronary angioplasty and mammary graft lesions that were confirmed by conventional angiography: one patient had a significant stenosis (>50% stenosis) at the mammary bypass graft anastomosis site; three other had non-significant stenosis (<50% stenosis) including a mild lesion of the saphenous vein patch in two patients and a mild lesion at the anastomosis site of the mammary bypass in one. All segments identified as normal by CT in the other 11 children were also found to be normal by conventional angiography. Conclusion: In centers expert in this technique, 64-slice CT scanning is a promising, rapid, and useful diagnostic technique for evaluating both coronary angioplasty and bypass graft lesions in children who had undergone coronary artery surge0008.

  11. MR imaging compared with CT, angiography, and myelography supplemented with CT in the diagnosis of spinal tumors

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro; Uchino, Akira; Matsumoto, Shunichi; Fujii, Kiyotaka; Fukui, Masashi; Masuda, Kouji (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    To clarify the significance of MR imaging and the present status of CT, angiography, and myelography supplemented by CT (M-CTM), the radiological findings of 50 spinal tumors were reviewed and analyzed. MR imaging was most effective for visualizing morphological features such as the margins and/or inner structures of the tumors. CT was also effective for imaging 'dumbbell' neurinomas and extradural tumors. Angiography was necessary in one hemangioblastoma and in cervical extradural tumors. M-CTM visualized the morphology of intradural extramedullary tumors and extradural tumors, but provided no new information in most of these cases. It was concluded that when using MR the indications for CT, angiography, and M-CTM are limited and that CT or angiography should be performed only in selected cases. M-CTM appeared to be unnecessary. (author).

  12. CT angiography versus 3D rotational angiography in patients with subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Bechan, R.S.; Peluso, J.P.; Sluzewski, M.; Rooij, W.J. van [Sint Elisabeth Ziekenhuis Tilburg, Department of Radiology, Tilburg (Netherlands); Rooij, S.B. van [Medisch Centrum Alkmaar, Department of Radiology, Alkmaar (Netherlands); Sprengers, M.E.; Majoie, C.B. [Academisch Medisch Centrum, Department of Radiology, Amsterdam (Netherlands)

    2015-12-15

    CT angiography (CTA) is increasingly used as primary diagnostic tool to replace digital subtraction angiography (DSA) in patients with subarachnoid hemorrhage (SAH). However, 3D rotational angiography (3DRA) has substituted DSA as a reference standard. In this prospective observational study, we compare CTA with 3DRA of all cerebral vessels in a large cohort of patients with SAH. Of 179 consecutive patients with SAH admitted between March 2013 and July 2014, 139 underwent 64- to 256-detector row CTA followed by complete cerebral 3DRA within 24 h. In 86 patients (62 %), 3DRA was performed under general anesthesia. Two observers from outside hospitals reviewed CTA data. In 118 of 139 patients (85 %), 3DRA diagnosed the cause of hemorrhage: 113 ruptured aneurysms, three arterial dissections, one micro-arteriovenous malformation (AVM), and one reversible vasoconstriction syndrome. On CTA, both observers missed all five non-aneurysmal causes of SAH. Sensitivity of CTA in depicting ruptured aneurysms was 0.88-0.91, and accuracy was 0.88-0.92. Of 113 ruptured aneurysms, 28 were ≤3 mm (25 %) and of 95 additional aneurysms, 71 were ≤3 mm (75 %). Sensitivity of depicting aneurysms ≤3 mm was 0.28-0.43. Of 95 additional aneurysms, the two raters missed 65 (68 %) and 58 (61 %). Sensitivity in detection was lower in aneurysms of the internal carotid artery than in other locations. CTA had some limitations as primary diagnostic tool in patients with SAH. All non-aneurysmal causes for SAH and one in ten ruptured aneurysms were missed. Performance of CTA was poor in aneurysms ≤3 mm. The majority of additional aneurysms were not depicted on CTA. (orig.)

  13. Age-related risk of major adverse cardiac event risk and coronary artery disease extent and severity by coronary CT angiography: results from 15 187 patients from the International Multisite CONFIRM Study

    Science.gov (United States)

    Nakazato, Ryo; Arsanjani, Reza; Achenbach, Stephan; Gransar, Heidi; Cheng, Victor Y.; Dunning, Allison; Lin, Fay Y.; Al-Mallah, Mouaz; Budoff, Matthew J.; Callister, Tracy Q.; Chang, Hyuk-Jae; Cademartiri, Filippo; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; DeLago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Kaufmann, Philipp; Raff, Gilbert; Shaw, Leslee J.; Villines, Todd; Cury, Ricardo C.; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Berman, Daniel S.; Min, James K.

    2014-01-01

    Aims Prior studies evaluating the prognostic utility of cardiac CT angiography (CCTA) have been largely constrained to an all-cause mortality endpoint, with other cardiac endpoints generally not reported. To this end, we sought to determine the relationship of extent and severity of coronary artery disease (CAD) by CCTA to risk of incident major adverse cardiac events (MACEs) (defined as death, myocardial infarction, and late revascularization). Methods and results We identified subjects without prior known CAD who underwent CCTA and were followed for MACE. CAD by CCTA was defined as none (0% luminal stenosis), mild (1–49% luminal stenosis), moderate (50–69% luminal stenosis), or severe (≥70% luminal stenosis), and ≥50% luminal stenosis was considered as obstructive. CAD severity was judged on per-patient, per-vessel, and per-segment basis. Time to MACE was estimated using univariable and multivariable Cox proportional hazards models. Among 15 187 patients (57 ± 12 years, 55% male), 595 MACE events (3.9%) occurred at a 2.4 ± 1.2 year follow-up. In multivariable analyses, an increased risk of MACE was observed for both non-obstructive [hazard ratio (HR) 2.43, P < 0.001] and obstructive CAD (HR: 11.21, P < 0.001) when compared with patients with normal CCTA. Risk-adjusted MACE increased in a dose–response relationship based on the number of vessels with obstructive CAD ≥50%, with increasing hazards observed for non-obstructive (HR: 2.54, P < 0.001), obstructive one-vessel (HR: 9.15, P < 0.001), two-vessel (HR: 15.00, P < 0.001), or three-vessel or left main (HR: 24.53, P < 0.001) CAD. Among patients stratified by age <65 vs. ≥65 years, older individuals experienced higher risk-adjusted hazards for MACE for non-obstructive, one-, and two-vessel, with similar event rates for three-vessel or left main (P < 0.001 for all) compared with normal individuals age <65. Finally, there was a dose relationship of CAD findings by CCTA and MACE event rates with each

  14. Usefulness of helical CT angiography for diagnosis of anomalous origin of coronary artery. Comparison with coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Shinozaki, Hitoshi; Kondo, Takeshi; Ishikawa, Emiko [Fujita Health Univ., Toyoake, Aichi (Japan)] [and others

    1998-07-01

    Usefulness of helical CT angiography with reconstruction image of diastolic phase synchronized with electrocardiogram was compared with that of coronary angiography for diagnosis of anomalous origin of coronary artery. Patients were 2 males and 3 females, and average age was 66.4 year. Three cardiologists judged images and did not confirmed the origin and direction of coronary artery in 60% of cases. Helical CT was carried out with heartbeat <60/min by oral administration of propranolol (10-20 mg) one hour before the test. Half image was reconstructed by using data of diastolic phase which is 600 msec back from R-wave of an electrocardiogram. Multiplanar reconstruction (MPR) image and 3D image were provided. Two radiologists judged these images. A judgment was completed with 4 cases among 5 cases, and two judgments agreed well. For diagnosis of anomalous origin of coronary artery, helical CT had good accuracy and was more sensitive than coronary angiography. (K.H.)

  15. Hepatic arterial supply in 1297 CT-angiographies; Die arterielle Leberversorgung in 1297 CT-Angiografien

    Energy Technology Data Exchange (ETDEWEB)

    Loeschner, C.; Kausche, S.; Teichgraeber, U. [Jena University Hospital, Jena (Germany). Dept. of Radiology; Nagel, S.N. [Charite Universitaetsmedizin Berlin (Germany). Dept. of Radiology

    2015-04-15

    Analysis, evaluation and classification of hepatic arterial supply variants and determination of their frequency distribution in CT-angiographies. CT-angiographies of 1,568 patients were evaluated retrospectively for the period between January 1, 2010 and August 30, 2012. The hepatic arterial anatomy was assessed and categorized according to Michels's classification. So far unclassified variants were considered separately. Results: CT-angiographies of 1297 patients were included in the study. Type I according to Michels was seen in 937 cases (72.2%), followed by type V in 114 patients (8.8%) and type III in 83 patients (6.4%). Type X could not be found in any of the patients. Not yet classified variants were discovered in 26 patients. The most frequent variant in this connection was a right hepatic artery originating from the superior mesenteric artery with the left hepatic artery originating from the left gastric artery (n=10). Michels's classification could be largely confirmed on the basis of a radiologically examined patient population. Not yet classified variants were categorized into subgroups of the existing classification.

  16. Pulmonary embolism during pregnancy: diagnosis with lung scintigraphy or CT angiography?

    Science.gov (United States)

    Revel, Marie-Pierre; Cohen, Stéphanie; Sanchez, Olivier; Collignon, Marie-Anne; Thiam, Rokhaya; Redheuil, Alban; Meyer, Guy; Frija, Guy

    2011-02-01

    To evaluate the rate of positive, negative, and indeterminate results and the agreement between initial and expert readings for lung scintigraphy and computed tomographic (CT) angiography performed in patients suspected of having pulmonary embolism (PE) during pregnancy. Institutional review board approval was obtained. The authors retrospectively analyzed the images from lung scintigraphy and CT angiography performed in pregnant patients during the past 9 years. Images from 46 CT angiographic examinations performed in 43 patients and 91 of 94 lung scintigraphic examinations were reviewed by experts, whose readings were then compared with the initial reports. For CT angiography, the quality of opacification was graded as good, suboptimal, or poor and intraarterial attenuation was measured. The rates of positive findings (seven of 43 patients [16%] with CT angiography and 10 of 91 patients [11%] with scintigraphy, P = .36), negative findings (28 of 43 patients [65%] with CT angiography and 64 of 91 patients [70%] with scintigraphy, P = .54), and indeterminate findings (eight of 43 patients [19%] with CT angiography and 17 of 91 patients [19%] with scintigraphy, P = .99) were similar for CT angiography and lung scintigraphy. There were four discrepancies between initial and expert readings for CT angiography (κ = 0.84; confidence interval: 0.68, 0.99) and 14 for lung scintigraphy (κ = 0.75; 95% confidence interval: 0.63, 0.87). Opacification was classified as good for only 23 of the 46 CT angiographic examinations (50%). Attenuation values were significantly different among the groups with good, suboptimal, or poor opacification. Alternative diagnoses unsuspected at chest radiography were demonstrated at CT angiography in five of the 43 patients (12%). The mean maternal radiation dose was 0.9 mSv for lung scintigraphy and 7.3 mSv for CT angiography. Lung scintigraphy and CT angiography have comparable performances for PE diagnosis during pregnancy. Interobserver

  17. Comparative evaluation of 64-slice CT angiography and digital subtraction angiography in assessing the cervicocranial vasculature

    Directory of Open Access Journals (Sweden)

    Randolf Klingebiel

    2008-08-01

    Full Text Available Randolf Klingebiel1, Max Kentenich3, Hans-Christian Bauknecht3, Florian Masuhr2, Eberhard Siebert1, Markus Busch2, Georg Bohner11Department of Neuroradiology, 2Department of Neurology, 3Department of Radiology, Charité Universitary Medicine Berlin, GermanyBackground: Noninvasive 64-slice computed tomography angiography (64-MSCTA closely approximates conventional catheter angiography (DSA in terms of detail resolution. Objective: Retrospective evaluation of cervicocranial (cc 64-MSCTA in comparison with DSA in patients with presumptive cc vascular disorders.Material and methods: Twenty-four 64-MSCTA studies (32 mm detector width, slice thickness 0.5 mm, 120 kv, 150 mAs, pitch 0.75 of patients with presumptive cc vascular pathology (13 men, 11 women, mean age 38.3 ± 11.3 yrs, range 19–54 yrs were assessed in comparison with DSA studies without abnormal findings in age-matched patients (11 men, 13 women, mean age 39.7 ± 11.9 yrs, range 18–54 yrs. Study readings were performed in a blinded manner by two neuroradiologists with respect to image quality and assessibility of various cc vascular segments by using a five-point scale. Radiation exposure was calculated for 64-MSCTA.Results: Each reader assessed 384/528 different vessel segments (64-MSCTA/DSA. Superior image quality was attributed to DSA with respect to the C1 ICA–C6 ICA, A3 ACA, and P3 PCA segments as well the AICA and SCA. 64-MSCTA was scored superior for C7 ICA and V4 VA segments. A significantly increased number of nonassessable V2- and V3 VA segments in DSA studies was noted. The effective dose for 64-MSCTA amounted to 2.2 mSv.Conclusions: 64-MSCTA provides near-equivalent diagnostic information of the cc vasculature as compared with DSA. According to our results, DSA should be considered primarily when peripheral vessels (A3/P3 or ICA segments close to the skull base (C2-5 are of interest, such as in primary angiitis or stenoocclusive ICA disease, respectively.Keywords: CT-angiography

  18. The effect of low-dose β-blocker on heart rate and heart rate variability in health subjects wth a resting heart rate of less than 65 beats per minute: Effect on the quality of prospective electrocardiography-gated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chul Hwan; Kim, Tae Hoon [Dept. of Radiology and Research Institute of Radiological Science, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Sang Min [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Hong, Yoo Jin [Dept. of Radiology and Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2015-02-15

    We assessed the effect of a low-dose β-blocker on heart rate (HR), HR variability (HRV) and image quality of prospective electrocardiography-gated coronary CT angiography (CCTA) in healthy subjects with low HR. CCTA was performed with a 64-slice CT in 75 subjects with a HR of less than 65 beats per minute (bpm). Subjects were divided into 2 groups: Group 1 (G1), 35 with a low dose β-blocker; and Group 2 (G2), 40 without pre-medication. The image quality (IQ) of the CCTA was assessed on a 4-point grading scale (1, poor; 4, excellent). Initial HR (bpm) was not different between the 2 groups. HR during CCTA was lower in G1 than G2 (50.3 ± 5.6 vs. 53.3 ± 4.8, p = 0.016). HRV was not different between the 2 groups. Per-segment analysis showed better IQ at the mid-segment of the right coronary artery (3.0 ± 0.9 vs. 2.5 ± 1.1, p = 0.039) and the first diagonal branch (3.4 ± 0.6 vs. 3.1 ± 0.7, p = 0.024), in the G1 than the G2 group, respectively. The IQ was negatively correlated with HR, but no correlation was found between HRV and IQ. The IQs in the per-vessel analysis were not different between the 2 groups. Low-dose β-blocker reduced HR and improved the IQ of CCTA in a few segments, even at a HR of less than 65 bpm. However the effect was limited.

  19. Angiography-based C-arm CT for the assessment of extrahepatic shunting before radioembolization

    Energy Technology Data Exchange (ETDEWEB)

    Heusner, Till Alexander; Hahn, S.; Forsting, M.; Antoch, G. [Inst. fuer Diagnostische und Interventionelle Radiologie und Neuroradiologie, Universitaetsklinik Essen (Germany); Hamami, M.E.; Poeppel, T.; Bockisch, A. [Klinik fuer Nuklearmedizin, Universitaetsklinik Essen (Germany); Ertle, J.; Hilgard, P. [Klinik fuer Gastroenterologie, Universitaetsklinik Essen (Germany)

    2010-07-15

    Purpose: to retrospectively assess the accuracy of angiography-based C-arm CT for the detection of extrahepatic shunting before SIRT. Materials and methods: 30 patients (mean age: 64 {+-} 12 years) with hypervascularized hepatic tumors underwent hepatic angiography, coil embolization of gastrointestinal collaterals and 99mTc-macroaggregated albumin (MAA) SPECT/CT before SIRT. Before MAA injection via a microcatheter from the intended treatment position, an angiography and angiography-based C-arm CT (XperCT trademark, Philips Healthcare) were acquired. Angiographies and XperCT trademark were performed from 48 microcatheter positions followed by MAA injections and MAA-SPECT/CT. MAA-SPECT/CT served as the reference standard for determining the accuracy of hepatic arteriography and C-arm CT for the detection of extrahepatic shunting. Results: MAA-SPECT/CT revealed extrahepatic shunting in 5 patients (17%). Hepatic arteriography yielded a true negative in 22 (73%), a false negative in 5 (17%), and an unclear result in 3 patients (10%). C-arm CT yielded a true positive in 3 (10%), true negative in 24 (80%), false positive in 1 (3%), and false negative in 2 patients (7%). The specificity and the NPV of hepatic arteriography for the detection of extrahepatic shunting were 88% and 81%, respectively. For C-arm CT the sensitivity, specificity, PPV, NPV, and accuracy for the detection of extrahepatic shunting were 60%, 96%, 75%, 92%, and 90%, respectively. Conclusion: C-arm CT offers additional information to angiography when assessing SIRT patients for extrahepatic shunting. More accurate detection of extrahepatic shunting may optimize the workflow in SIRT preparations by avoiding unnecessary repeat angiographies. (orig.)

  20. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  1. CT angiography and Color Doppler ultrasonography features and sensitivity in detection of carotid arteries diseases

    Directory of Open Access Journals (Sweden)

    Samir Kamenjaković

    2013-04-01

    Full Text Available Introduction: The aim of this research was to compare specifi city and sensitivity of Color Doppler ultrasonographywith CT angiography.Methods: A total of one hundred patients suffering from carotid artery disease (n=200 were tested in this research in the period from June till October, 2011. Average age of the patients was 61.5 years, and most of the patients were in the age group ranging from 55 to 65 years. The level of carotid artery stenosis is measured according to Standards of the North America Symptomatic Carotid Endarterectomy Trail study,by method of Color Doppler ultrasonography and CT angiography.Results: Stenosis <50% registered by Doppler ultrasonography was found in 62% and by CT angiography in 64% patients. Stenosis from 70 to 79% registered by Doppler ultrasonography was found in 88% and by CT angiography in 82% patients. In patients with level of stenosis 70-79% there was a tendencyof registering the stenosis to be higher by Color Doppler ultrasonography, than by CT angiography. In the case of the occlusion, there was also the similar observation, with variation of 8% carotid arteries.Conclusion: Extracranial Doppler and color duplex ultrasound enable reliable detection of both stenosis and occlusion of carotid arteries and accordingly they occupy an important place in radiological algorithm. When it comes to CT angiography it can be concluded that it can provide accurate and exact information regarding the condition of blood vessels as good as Digital Subtractive Angiography can.

  2. Assessment Of Coronary Arterial Stents By Multislice-CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Maintz, D.; Fallenberg, E. M.; Heindel, W.; Fischbach, R. [Univ. of Muenster (Germany). Dept. of Clinical Radiology; Grude, M. [Univ. of Muenster (Germany). Dept. of Cardiology and Angiology

    2003-11-01

    Purpose: To assess patency and lumen visibility of coronary artery stents by multislice-CT angiography (MSCTA) in comparison with conventional coronary angiography as the standard of reference. Material and Methods: 47 stents of 13 different types were evaluated in 29 patients. MSCTA was performed on a 4-slice scanner with a standard coronary protocol (detector collimation 4 x 1 mm; table feed 1.5 mm/rotation, 400 mAs, 120 kV). Image evaluation was performed by two readers who were blinded to the reports from the catheter angiography. MIP reconstructions were evaluated for image quality on a 4-point scale (1 = poor, 4 = excellent) and stent patency (contrast distal to the stent as an indirect patency sign). Axial images and multiplanar reformations through the stents were used for assessment of stent lumen visibility (measurement of the visible stent lumen diameter) and detection of relevant in-stent stenosis (50%). Results: Image quality was fair to good on average (score 2.64 {+-} 1.0) and depended on the heart rate (heart rate 45-60: average score 3.2, heart rate 61-70: average score 2.8, heart rate >71: average score 1.4). Thirty-seven stents were correctly classified as patent, 1 was correctly classified as occluded and 9 stents were not assessable due to insufficient image quality because of triggering artifacts. Parts of the stent lumen could be visualized in 30 cases. On average, 20-40% of the stent lumen diameter was visible. Twenty-five stents were correctly classified as having no stenosis, 1 was falsely classified as stenosed, 1 was correctly classified as occluded. In 20 stents lumen visibility was not sufficient for stenosis evaluation. Conclusion: Although the stent lumen may be partly visualized in most stents, a reliable evaluation of in-stent stenoses does not seem practical by 4-slice MSCT. Nevertheless, for stent patency evaluation, MS-CTA might provide valuable clinical information. With submillimeter MSCT (e.g. 16-slice scanners) and more

  3. Application of 70 kV Third-generation High-pitch Dual-source Coronary CT Angiography in Patients with Different Body Mass Index.

    Science.gov (United States)

    Yi, Yan; Cao, Jian; Lin, Lu; Kong, Lingyan; Jiang, Shu; Li, Xiao; Liu, Peijun; Wang, Ming; Wang, Man; Wang, Yun; Jin, Zhengyu; Wang, Yining

    2017-02-20

    Objective  To investigate the optimized range of body mass index (BMI) selection for patients undergoing 70 kV high-pitch dual-source coronary CT angiography (CCTA) on the third-generation dual-source CT (DSCT). Methods  Patients undergoing prospective high-pitch ultra-low contrast media (CM) CCTA on the third-generation DSCT using the automatic tube voltage selection at 70 kV were included and divided into three groups:group A,with BMI≤24 kg/m(2);group B,with 24 kg/m(2)image quality results,and effective dose (ED) were evaluated and compared. Results  No significant difference was found in age (H=2.36,P=0.78),heart rate (H=3.51,P=0.80),and ED(H=1.77,P=0.12) among three groups. The noise of the aortic root in group A was (21.66±4.00)HU,which was significantly lower than that in group C [(23.61±4.20)HU](F=2.05,P=0.03). The signal to noise ratio of aortic root in group A (18.61±5.28) was significantly better than that in group C (14.75±2.58) (F=5.31,P=0.02). No other significant difference in quantitative image quality were found among the three groups (all P >0.05). Subjective image quality in group A(Z=2.91,P=0.004) and B(Z=2.27,P=0.021) were both significantly better than that in group C. Conclusion  The ultra-low tube voltage (70 kV) combined with ultra-low CM CCTA protocol on third-generation high-pitch DSCT may be better for patients with BMI<28 kg/m2 than those with BMI ≥28 kg/m(2) in China.

  4. Anatomic distribution of embolus at CT pulmonary angiography in patients suspected acute pulmonary embolism

    Institute of Scientific and Technical Information of China (English)

    朱力

    2013-01-01

    Objective To summarize and analyze the morphology and distribution of embolus in patients suspected acute pulmonary embolism. Methods The CT pulmonary angiography(CTPA) imagings of 279 patients suspected acute pulmonary embolism were analyzed retrospectively in

  5. What Have We Learned from CONFIRM? Prognostic Implications from a Prospective Multicenter International Observational Cohort Study of Consecutive Patients Undergoing Coronary Computed Tomographic Angiography

    Science.gov (United States)

    Otaki, Yuka; Arsanjani, Reza; Gransar, Heidi; Cheng, Victor Y.; Dey, Damini; Labounty, Troy; Lin, Fay Y.; Achenbach, Stephan; Al-Mallah, Mouaz; Budoff, Matthew J.; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin J. W.; Delago, Augustin; Hadamitzky, Martin; Hausleiter, Joerg; Kaufmann, Philipp; Maffei, Erica; Raff, Gilbert; Shaw, Leslee J.; Villines, Todd C.; Dunning, Allison; Cury, Ricardo C.; Feuchtner, Gudrun; Kim, Yong-Jin; Leipsic, Jonathon; Berman, Daniel S.; Min, James K.

    2014-01-01

    Coronary computed tomographic angiography (CCTA) employing CT scanners of 64-detector rows or greater represents a novel noninvasive method for detection of coronary artery disease (CAD), providing excellent diagnostic information when compared to invasive angiography. In addition to its high diagnostic performance, prior studies have shown that CCTA can provide important prognostic information, although these prior studies have been generally limited to small cohorts at single centers. The Coronary CT Angiography EvaluatioN For clinical Outcomes: An InterRnational Multicenter Registry, or CONFIRM, is a large, prospective, multinational, dynamic observational cohort study of patients undergoing CCTA. This registry currently represents more than 32,000 consecutive adults suspected of having CAD who underwent ≥ 64–detector row CCTA at 12 centers in 6 countries between 2005 and 2009. Based on its large sample size and adequate statistical power, the data derived from CONFIRM registry has and will continue to provide key answers to many important topics regarding CCTA. Based on its multisite international national design, the results derived from CONFIRM should be considered as more generalizable than prior smaller single-center studies. This article summarizes the current status of several studies from CONFIRM registry. PMID:22689072

  6. Coronary CT Angiography Versus Standard Emergency Department Evaluation for Acute Chest Pain and Diabetic Patients: Is There Benefit With Early Coronary CT Angiography? Results of the Randomized Comparative Effectiveness ROMICAT II Trial.

    Science.gov (United States)

    Truong, Quynh A; Schulman-Marcus, Joshua; Zakroysky, Pearl; Chou, Eric T; Nagurney, John T; Fleg, Jerome L; Schoenfeld, David A; Udelson, James E; Hoffmann, Udo; Woodard, Pamela K

    2016-03-22

    Cardiac computed tomography angiography (CCTA) reduces emergency department length of stay compared with standard evaluation in patients with low- and intermediate-risk acute chest pain. Whether diabetic patients have similar benefits is unknown. In this prespecified analysis of the Rule Out Myocardial Ischemia/Infarction by Computer Assisted Tomography (ROMICAT II) multicenter trial, we randomized 1000 patients (17% diabetic) with symptoms suggestive of acute coronary syndrome to CCTA or standard evaluation. The rate of acute coronary syndrome was 8% in both diabetic and nondiabetic patients (P=1.0). Length of stay was unaffected by the CCTA strategy for diabetic patients (23.9 versus 27.2 hours, P=0.86) but was reduced for nondiabetic patients compared with standard evaluation (8.4 versus 26.5 hours, Pemergency department discharge in both groups (each P≤0.0001, P interaction=0.27). No difference in hospital admissions was seen between the 2 strategies in diabetic and nondiabetic patients (P interaction=0.09). Both groups had more downstream testing and higher radiation doses with CCTA, but these were highest in diabetic patients (all P interaction≤0.04). Diabetic patients had fewer normal CCTAs than nondiabetic patients (32% versus 50%, P=0.003) and similar normalcy rates with standard evaluation (P=0.70). Notably, 66% of diabetic patients had no or mild stenosis by CCTA with short length of stay comparable to that of nondiabetic patients (P=0.34), whereas those with >50% stenosis had a high prevalence of acute coronary syndrome, invasive coronary angiography, and revascularization. Knowledge of coronary anatomy with CCTA is beneficial for diabetic patients and can discriminate between lower risk patients with no or little coronary artery disease who can be discharged immediately and higher risk patients with moderate to severe disease who warrant further workup. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT01084239. © 2016 The Authors

  7. Clinical utility and cost-effectiveness of CT-angiography in the diagnosis of nontraumatic subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Jabbarli, Ramazan; Shah, Mukesch; Hippchen, Beate; Velthoven, Vera van [University Hospital of Freiburg, Department of Neurosurgery, Freiburg/Breisgau (Germany); Taschner, Christian [University Hospital of Freiburg, Department of Neuroradiology, Freiburg (Germany); Kaier, Klaus [University Hospital of Freiburg, Institute for Medical Biometry and Medical Informatics, Freiburg (Germany)

    2014-10-15

    CT-angiography gains an increasing role in the initial diagnosis of patients with nontraumatic subarachnoid hemorrhage (SAH). However, the implementation of CT-angiography does not always exclude the necessity of conventional angiography. Our objective was to determine the practical utility and cost-effectiveness of CT-angiography. All patients with nontraumatic subarachnoid hemorrhage admitted to our university hospital after implementation of CT-angiography between June 1, 2011 and June 30, 2012 were retrospectively analyzed in regard to factors of treatment flow, radiation exposure, harms of contrast medium loading, and diagnostic costs. A control group of the same size was assembled from previously admitted SAH patients, who did not undergo pretreatment CT-angiography. Furthermore, cost-effectiveness analysis was performed. The final analysis consisted of 93 patients in each group. Of 93 patients with pretreatment CT-angiography, 74 had to undergo conventional angiography for diagnostic and/or therapeutic purposes. CT-angiography had significant impact on the reduction of collective effective radiation dose by 4.419 mSv per person (p = 0.0002) and was not associated with additional harms. Despite the significantly earlier detection of aneurysms with CT-angiography (p < 0.0001), there were no significant differences in the timing of aneurysm repair and duration of ICU and general hospital stay. There was an increase of diagnostic costs - the cost-effectiveness analysis showed, however, that benefits of CT-angiography in respect to radiation exposure and risk of conventional angiography-related complications justify the additional costs of CT-angiography. Although the implementation of CT-angiography in SAH diagnosis cannot completely replace conventional angiography, it can be approved in regard to radiation hygiene and cost-effectiveness. (orig.)

  8. Improved dynamic CT angiography visualization by flow territory masking

    Directory of Open Access Journals (Sweden)

    Søren Christensen

    2015-01-01

    Full Text Available Backgound and Purpose: Computerized tomography (CT perfusion (or CTP source images from CT scanners with small detector widths can be used to create a dynamic CT angiogram (CTA similar to digital subtraction angiography (DSA. Because CTP studies use a single intravenous injection, all arterial territories enhance simultaneously, and individual arterial territories [i.e., anterior cerebral artery (ACA, middle cerebral artery (MCA, and posterior cerebral artery (PCA] cannot be delineated. This limits the ability to assess collateral flow patterns on dynamic CTAs. The aim of this study was to devise and test a postprocessing method to selectively color-label the major arterial territories on dynamic CTA. Materials and Methods: We identified 22 acute-stroke patients who underwent CTP on a 320-slice CT scanner within 6 h from symptom onset. For each case, two investigators independently generated an arterial territory map from CTP bolus arrival maps using a semiautomated method. The volumes of the arterial territories were calculated for each map and the average relative difference between these volumes was calculated for each case as a measure of interrater agreement. Arterial territory maps were superimposed on the dynamic CTA to create a vessel-selective dynamic CTA with color-coding of the main arterial territories. Two experts rated the arterial territory maps and the color-coded CTAs for consistency with expected arterial territories on a 3-point scale (excellent, moderate, poor. Results: Arterial territory maps were generated for all 22 patients. The median difference in arterial territory volumes between investigators was 2.2% [interquartile range (IQR 0.6-8.5%]. Based on expert review, the arterial territory maps and the vessel-selective dynamic CTAs showed excellent consistency with the expected arterial territories in 18 of 22 patients, moderate consistency in 2 patients, and poor consistency in another 2 patients. Conclusion: Using a

  9. Improved diagnosis of actively bleeding aneurysm on CT angiography using delayed CT images

    Energy Technology Data Exchange (ETDEWEB)

    Kathuria, Sudhir, E-mail: skathur2@jhmi.edu [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Division of Interventional Neuroradiology, Department of Neurology and Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Deveikis, John P.; Westesson, Per-Lennart [Division of Diagnostic and Interventional Neuroradiology, Department of Imaging Sciences, University of Rochester Medical Center, Rochester, NY 14642 (United States); Gandhi, Dheeraj [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, MD (United States); Division of Interventional Neuroradiology, Department of Neurology and Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, MD (United States)

    2011-08-15

    Computed tomographic angiography (CTA) is being increasingly utilized in the non-invasive diagnosis of aneurysmal subarachnoid hemorrhage (SAH). There are emerging reports of diagnosis of active aneurysmal bleeding on CTA, furthering our understanding of imaging features of active extravasation on cross-sectional studies. We demonstrate imaging characteristics of two such cases of active contrast extravasation from intracranial aneurysms. Additionally, we demonstrate that delayed CT images greatly improve the confidence of this diagnosis by demonstrating pooling of contrast in the subarachnoid space. Prompt recognition and management can improve prognosis of this potentially lethal condition.

  10. Timing-Invariant CT Angiography Derived from CT Perfusion Imaging in Acute Stroke : A Diagnostic Performance Study

    NARCIS (Netherlands)

    Smith, E. J.; Vonken, E. -J.; Meijer, F. J. A.; Dankbaar, J. W.; Horsch, A. D.; van Ginneken, B.; Velthuis, B.; van der Schaaf, I.; Prokop, M.

    2015-01-01

    BACKGROUND AND PURPOSE: Timing-invariant (or delay-insensitive) CT angiography derived from CT perfusion data may obviate a separate cranial CTA in acute stroke, thus enhancing patient safety by reducing total examination time, radiation dose, and volume of contrast material. We assessed the diagnos

  11. Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States); Juan, Yu-Hsiang [Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States); Chang Gung Memorial Hospital, Linkou and Chang Gung University, Department of Medical Imaging and Intervention, Taoyuan (China); Wang, Qiushi; Huang, Hongfei; Yang, Lin [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Xie, Zhaofeng [Guangdong Academy of Medical Sciences, Department of Pediatric Cardiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Chen, Jimei; Zhang, Xiaoshen [Guangdong Academy of Medical Sciences, Department of Cardiovascular Surgery, Guangdong General Hospital, GuangZhou, GuangDong (China); Liang, Changhong [Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, GuangZhou, GuangDong (China); Guangdong Academy of Medical Sciences, Department of Radiology, Guangdong General Hospital, Guangzhou (China); Chung, Taylor [Children' s Hospital and Research Center Oakland, Department of Diagnostic Imaging, Oakland, CA (United States); Kwong, Raymond Y.; Saboo, Sachin S. [Brigham and Women' s Hospital, Harvard Medical School, Cardiovascular Imaging Program, Department of Medicine (Division of Cardiovascular Medicine) and Radiology, Boston, MA (United States)

    2014-12-15

    To analyze 15 cases of malposition of branch pulmonary arteries (MBPA) for the hospital-based prevalence, clinical information, surgical outcome, imaging findings, associated cardiovascular and airway abnormalities on cardiovascular computed tomography angiography (CCTA). We retrospectively searched for patients with MBPA from our database consisting of patients referred for CCTA due to known or suspected congenital heart disease and also from all patients receiving chest computed tomography (CT) during the same time period. We analyzed the hospital-based prevalence, image findings, associated cardiovascular anomalies, airway compression, and recorded the clinical information and surgical outcome. Our study showed 15 patients with MBPA (hospital-based prevalence: 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving chest CT or CCTA). Classic type was more common than lesser type (67 % versus 33 %). All patients had associated cardiovascular anomalies, including aortic arch abnormalities (80 %) and secondary airway compression (33 %). Surgery was performed in 67 % of cardiovascular anomalies and 60 % of airway stenoses. MBPA has a hospital-based prevalence of 0.33 % among patients with congenital heart disease and 0.06 % in all patients receiving either chest CT or CCTA. CCTA can delineate the anatomy of MBPA, associated cardiovascular and airway abnormalities for preoperative evaluation. (orig.)

  12. Titanium plate artefact mimicking popliteal artery dissection on digital subtraction CT angiography.

    Science.gov (United States)

    Woodacre, Timothy; Wienand-Barnett, Sophie

    2013-04-05

    Titanium plates used for the internal fixation of long bone fractures cause significant artefact on CT scans but have not been reported to affect digital subtraction CT angiography. We present a patient with clinical suspicion of popliteal artery injury following a high tibial osteotomy. The osteotomy was stabilised with a titanium locking plate. During the digital subtraction process used to produce reconstruction CT angiography, removal of artefact caused by the titanium plate produced CT images mimicking the appearance of a popliteal artery dissection. The imaging inaccuracy was realised prior to the patient undergoing further intervention. We highlight the potential error caused by titanium plates on digital subtraction CT angiography and recommend careful analysis of such images prior to further treatment.

  13. Intravenous flat detector CT angiography for non-invasive visualisation of intracranial flow diverter: technical feasibility.

    Science.gov (United States)

    Struffert, Tobias; Saake, Marc; Ott, Sabine; Engelhorn, Tobias; Gölitz, Philipp; Kloska, Stephan; Doelken, Marc; Doerfler, Arnd

    2011-08-01

    To demonstrate the feasibility of intravenous Flat Detector CT Angiography (FD-CTA) for visualisation of intracranial Flow Diverting Devices. Flow Diverting Devices are used increasingly for treatment of intracranial aneurysms. A close follow up is necessary because it becomes obvious that a significant proportion of aneurysms treated with these devices remain patent. A minimally invasive method is highly desirable. In two patients treated with flow diverters a Flat Detector CT (FD-CT) with intravenous contrast medium application was performed. Post-processing was performed using commercially available software. In both patients the lumen of the device and the lumen of the aneurysm could be clearly evaluated. Some beam hardening artefacts due to the marker wires of the device were obvious. Flat Detector CT with intravenous contrast material application to evaluate flow-diverting devices seems to be feasible. Further studies are necessary to perform comparative evaluation of FD-CTA with angiography and other techniques like MRA or conventional CT angiography.

  14. Radiological findings of dissecting aneurysm -a correlative study of CT with angiography-

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Tae Yeong; Park, Jae Hyung; Kim, Seung Hyup; Han, Man Chung [College of Medicine, Seoul National University, Seoul (Korea, Republic of)

    1987-06-15

    This study comprised 16 patients with aortic dissecting aneurysm who were admitted to Seoul National University Hospital from May 1984 to January 1987. CT findings in 16 cases of aortic dissecting aneurysm were correlated with angiographic findings retrospectively. The results were analysed. 1. Number of male was 11 and that of female was 5. Male patients in fifties were most common and 4 in number. 13 patients had hypertension or history of hypertension among 14 patients. There were one case of Marfan's syndrome, preeclampsia and Takayasu's arteritis respectively. 2. There were 5 cases of DeBakey type I, 1 case of type II and 9 cases of types III dissecting aneurysm. Type III was most common. 3. CT confirmed as superior vena cava which was not identified whether it was superior vena cava or unopacified false lumen by angiography in one case. Regarding distal extent, authors defined A whose extent was proximal to diaphragm and B beyond it for convenience sake. There was one false negative case in CT among 16 cases which was diagnosed as dissecting aneurysm type IIIB by angiography and confirmed as type III surgically. One case was diagnosed as type IB by CT and as type IIIB by angiography and confirmed as type I surgically. Extent was more accurate in CT than angiography. One case was diagnosed as type II by CT but misdiagnosed as right atrial tumor by angiography. 4. Diagnostic sensitivities of CT and angiography in this study were 94% (15/16) respectively. CT was more advantageous in hemothorax, hemopericardium, hemomediastinum, unopacified false lumen, aortic wall calcification and getting information about mediastinum. In angiography aortic regurgitation and tear site and involvement of abdominal vessels could be observed.

  15. Usefulness of CT angiography in diagnosing acute gastrointestinal bleeding: A meta-analysis

    Science.gov (United States)

    Wu, Lian-Ming; Xu, Jian-Rong; Yin, Yan; Qu, Xin-Hua

    2010-01-01

    AIM: To analyze the accuracy of computed tomography (CT) angiography in the diagnosis of acute gastrointestinal (GI) bleeding. METHODS: The MEDLINE, EMBASE, Cancerlit, Cochrane Library database, Sciencedirect, Springerlink and Scopus, from January 1995 to December 2009, were searched for studies evaluating the accuracy of CT angiography in diagnosing acute GI bleeding. Studies were included if they compared CT angiography to a reference standard of upper GI endoscopy, colonoscopy, angiography or surgery in the diagnosis of acute GI bleeding. Meta-analysis methods were used to pool sensitivity and specificity and to construct summary receiver-operating characteristic. RESULTS: A total of 9 studies with 198 patients were included in this meta-analysis. Data were used to form 2 × 2 tables. CT angiography showed pooled sensitivity of 89% (95% CI: 82%-94%) and specificity of 85% (95% CI: 74%-92%), without showing significant heterogeneity (χ2 = 12.5, P = 0.13) and (χ2 = 22.95, P = 0.003), respectively. Summary receiver operating characteristic analysis showed an area under the curve of 0.9297. CONCLUSION: CT angiography is an accurate, cost-effective tool in the diagnosis of acute GI bleeding and can show the precise location of bleeding, thereby directing further management. PMID:20712058

  16. Left ventricular functional parameters and geometric patterns in Korean adults on coronary CT angiography with a 320-detector-row CT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Eun Ju; Lee, Ki Nam; Cho, Won Jin; Kim, Young Dae [College of Medicine, Dong-A University, Busan (Korea, Republic of); Shin, Kyung Min; Lim, Jae Kwang; Lee, Jong Min [Dept. of Radiology, Kyungpook National University, Daegu (Korea, Republic of)

    2017-08-01

    To assess the normal reference values of left ventricle (LV) functional parameters in Korean adults on coronary CT angiography (CCTA) with a 320-detector-row CT scanner, and to analyze sex-related differences and correlations with various clinical characteristics. This study retrospectively enrolled 172 subjects (107 men and 65 women; age, 58 ± 10.9 years; body surface area [BSA], 1.75 ± 0.2 m{sup 2}) who underwent CCTA without any prior history of cardiac disease. The following parameters were measured by post-processing the CT data: LV volume, LV functional parameters (ejection fraction, stroke volume, cardiac output, etc.), LV myocardial mass, LV inner diameter, and LV myocardial thickness (including septal wall thickness [SWT], posterior wall thickness [PWT], and relative wall thickness [RWT = 2 × PWT / LV inner diameter]). All of the functional or volumetric parameters were normalized using the BSA. The general characteristics and co-morbidities for the enrolled subjects were recorded, and the correlations between these factors and the LV parameters were then evaluated. The LV myocardial thickness (SWT, 1.08 ± 0.18 cm vs. 0.90 ± 0.17 cm, p < 0.001; PWT, 0.91 ± 0.15 cm vs. 0.78 ± 0.10 cm, p < 0.001; RWT, 0.38 ± 0.08 cm vs. 0.33 ± 0.05 cm, p < 0.001), LV volume (LV end-diastolic volume, 112.9 ± 26.1 mL vs. 98.2 ± 21.0 mL, p < 0.001; LV end-systolic volume, 41.7 ± 14.7 mL vs. 33.7 ± 12.2 mL, p = 0.001) and mass (145.0 ± 29.1 g vs. 107.9 ± 20.0 g, p < 0.001) were significantly greater in men than in women. However, these differences were not significant after normalization using BSA, except for the LV mass (LV mass index, 79.6 ± 14.0 g/m{sup 2} vs. 66.2 ± 11.0 g/m{sup 2},p < 0.001). The cardiac output and ejection fraction were not significantly different between the men and women (cardiac output, 4.3 ± 1.0 L/min vs. 4.2 ± 0.9 L/min, p = 0.452; ejection fraction, 63.4 ± 7.7% vs. 66.4 ± 7.6%, p = 0.079). Most of the LV parameters were

  17. Evaluation of malposition of the branch pulmonary arteries using cardiovascular computed tomography angiography.

    Science.gov (United States)

    Liu, Hui; Juan, Yu-Hsiang; Wang, Qiushi; Xie, Zhaofeng; Chen, Jimei; Huang, Hongfei; Zhang, Xiaoshen; Yang, Lin; Liang, Changhong; Chung, Taylor; Kwong, Raymond Y; Saboo, Sachin S

    2014-12-01

    To analyze 15 cases of malposition of branch pulmonary arteries (MBPA) for the hospital-based prevalence, clinical information, surgical outcome, imaging findings, associated cardiovascular and airway abnormalities on cardiovascular computed tomography angiography (CCTA). We retrospectively searched for patients with MBPA from our database consisting of patients referred for CCTA due to known or suspected congenital heart disease and also from all patients receiving chest computed tomography (CT) during the same time period. We analyzed the hospital-based prevalence, image findings, associated cardiovascular anomalies, airway compression, and recorded the clinical information and surgical outcome. Our study showed 15 patients with MBPA (hospital-based prevalence: 0.33% among patients with congenital heart disease and 0.06% in all patients receiving chest CT or CCTA). Classic type was more common than lesser type (67% versus 33%). All patients had associated cardiovascular anomalies, including aortic arch abnormalities (80%) and secondary airway compression (33%). Surgery was performed in 67% of cardiovascular anomalies and 60% of airway stenoses. MBPA has a hospital-based prevalence of 0.33% among patients with congenital heart disease and 0.06% in all patients receiving either chest CT or CCTA. CCTA can delineate the anatomy of MBPA, associated cardiovascular and airway abnormalities for preoperative evaluation. MBPA has a hospital-based prevalence of 0.33% among congenital heart disease patients. Classic type of MBPA was more common than lesser type. All MBPA patients had associated cardiovascular anomalies, 33% had secondary airway compression. CCTA delineates the anatomy of MBPA, associated cardiovascular and airway abnormalities. CCTA is beneficial in MBPA for preoperative evaluation and planning.

  18. Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

    OpenAIRE

    Cai, Weixing; zhao,binghui; Conover, David; Liu, Jiangkun; Ning, Ruola

    2012-01-01

    Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan.

  19. The clinical application of combined dualenergy CT pulmonary angiography and indirect venography

    Institute of Scientific and Technical Information of China (English)

    富青

    2013-01-01

    Objective To assess the usefulness of combined dual-energy CT pulmonary angiography (DE-CTPA) and indirect CT venography(CTV) in the diagnosis of venous thromboembolism(VTE). Methods Forty-nine patients with leg swelling suspected of pulmonary embolism(PE) underwent both DE-CTPA combined with CTV and lower

  20. Multidetector-row CT angiography of upper- and lower-extremity peripheral arteries

    Energy Technology Data Exchange (ETDEWEB)

    Willmann, J.K.; Wildermuth, S. [Inst. of Diagnostic Radiology, Univ. Hospital Zurich, Zurich (Switzerland)

    2005-11-15

    With the introduction of multidetector-row CT (MDCT) technology indications for MDCT angiography have expanded to include assessment of the peripheral arteries of the upper and lower extremities. Combined with patient- and scanner-adjusted CT data acquisition and contrast medium application strategies, an accurate and reliable evaluation of the peripheral arteries of the upper and lower extremities is possible. MDCT angiography is cost-effective and accurate for detection of arterial stenosis and occlusion in patients with peripheral arterial disease (PAD). MDCT angiography allows postoperative assessment of peripheral arterial bypass grafts, including bypass graft stenosis and occlusion, as well as presence of aneurysms or arteriovenous fistulas. In addition, MDCT angiography is helpful in particular for visualization of arterial bypass grafts with a complicated extra-anatomical course. Furthermore, pre-operative peripheral vascular mapping can be performed by using MDCT angiography. Finally, due to the integration of MDCT scanners in many trauma centres, MDCT angiography is increasingly being used for assessment of traumatic arterial injuries. This article gives an overview of technical aspects of peripheral MDCT angiography, including scanning parameters, contrast medium application, image postprocessing and radiation exposure, and summarizes the most frequent acute and non-acute indications of MDCT angiography for assessment of the upper- and lower-extremity peripheral arteries. (orig.)

  1. Minimally invasive post-mortem CT-angiography in a case involving a gunshot wound.

    Science.gov (United States)

    Ruder, Thomas D; Ross, Steffen; Preiss, Ulrich; Thali, Michael J

    2010-05-01

    Non-contrast post-mortem computed tomography (pm-CT) is useful in the evaluation of bony pathologies, whereas minimally invasive pm-CT-angiography allows for the detection of subtle vascular lesions. We present a case of an accidentally self-inflicted fatal bullet wound to the chest where pm-CT-angiography revealed a small laceration of the anterior interventricular branch of the left coronary artery and a tiny disruption of the right ventricle with pericardial and pleural effusion. Subsequent autopsy confirmed our radiological findings. Post-mortem CT-angiography has a great potential for the detection of vascular lesions and can be considered equivalent to autopsy for selected cases in forensic medicine.

  2. CT angiography and CT perfusion improve prediction of infarct volume in patients with anterior circulation stroke

    Energy Technology Data Exchange (ETDEWEB)

    Seeters, Tom van; Schaaf, Irene C. van der; Dankbaar, Jan Willem; Horsch, Alexander D.; Niesten, Joris M.; Luitse, Merel J.A.; Mali, Willem P.T.M.; Velthuis, Birgitta K. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Biessels, Geert Jan; Kappelle, L.J. [University Medical Center Utrecht, Department of Neurology, Brain Center Rudolf Magnus, Utrecht (Netherlands); Majoie, Charles B.L.M. [Academic Medical Center, Department of Radiology, Amsterdam (Netherlands); Vos, Jan Albert [St. Antonius Hospital, Department of Radiology, Nieuwegein (Netherlands); Schonewille, Wouter J. [St. Antonius Hospital, Department of Neurology, Nieuwegein (Netherlands); Walderveen, Marianne A.A. van [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Wermer, Marieke J.H. [Leiden University Medical Center, Department of Neurology, Leiden (Netherlands); Duijm, Lucien E.M. [Catharina Hospital, Department of Radiology, Eindhoven (Netherlands); Keizer, Koos [Catharina Hospital, Department of Neurology, Eindhoven (Netherlands); Bot, Joseph C.J. [VU University Medical Center, Department of Radiology, Amsterdam (Netherlands); Visser, Marieke C. [VU University Medical Center, Department of Neurology, Amsterdam (Netherlands); Lugt, Aad van der [Erasmus MC University Medical Center, Department of Radiology, Rotterdam (Netherlands); Dippel, Diederik W.J. [Erasmus MC University Medical Center, Department of Neurology, Rotterdam (Netherlands); Kesselring, F.O.H.W. [Rijnstate Hospital, Department of Radiology, Arnhem (Netherlands); Hofmeijer, Jeannette [Rijnstate Hospital, Department of Neurology, Arnhem (Netherlands); Lycklama a Nijeholt, Geert J. [Medical Center Haaglanden, Department of Radiology, The Hague (Netherlands); Boiten, Jelis [Medical Center Haaglanden, Department of Neurology, The Hague (Netherlands); Rooij, Willem Jan van [St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Kort, Paul L.M. de [St. Elisabeth Hospital, Department of Neurology, Tilburg (Netherlands); Roos, Yvo B.W.E.M. [Academic Medical Center, Department of Neurology, Amsterdam (Netherlands); Meijer, Frederick J.A. [Radboud University Medical Center, Department of Radiology, Nijmegen (Netherlands); Pleiter, C.C. [St. Franciscus Hospital, Department of Radiology, Rotterdam (Netherlands); Graaf, Yolanda van der [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Collaboration: Dutch acute stroke study (DUST) investigators

    2016-04-15

    We investigated whether baseline CT angiography (CTA) and CT perfusion (CTP) in acute ischemic stroke could improve prediction of infarct presence and infarct volume on follow-up imaging. We analyzed 906 patients with suspected anterior circulation stroke from the prospective multicenter Dutch acute stroke study (DUST). All patients underwent baseline non-contrast CT, CTA, and CTP and follow-up non-contrast CT/MRI after 3 days. Multivariable regression models were developed including patient characteristics and non-contrast CT, and subsequently, CTA and CTP measures were added. The increase in area under the curve (AUC) and R{sup 2} was assessed to determine the additional value of CTA and CTP. At follow-up, 612 patients (67.5 %) had a detectable infarct on CT/MRI; median infarct volume was 14.8 mL (interquartile range (IQR) 2.8-69.6). Regarding infarct presence, the AUC of 0.82 (95 % confidence interval (CI) 0.79-0.85) for patient characteristics and non-contrast CT was improved with addition of CTA measures (AUC 0.85 (95 % CI 0.82-0.87); p < 0.001) and was even higher after addition of CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001) and combined CTA/CTP measures (AUC 0.89 (95 % CI 0.87-0.91); p < 0.001). For infarct volume, adding combined CTA/CTP measures (R{sup 2} = 0.58) was superior to patient characteristics and non-contrast CT alone (R{sup 2} = 0.44) and to addition of CTA alone (R{sup 2} = 0.55) or CTP alone (R{sup 2} = 0.54; all p < 0.001). In the acute stage, CTA and CTP have additional value over patient characteristics and non-contrast CT for predicting infarct presence and infarct volume on follow-up imaging. These findings could be applied for patient selection in future trials on ischemic stroke treatment. (orig.)

  3. Evaluation of a Chest Circumference-Adapted Protocol for Low-Dose 128-Slice Coronary CT Angiography with Prospective Electrocardiogram Triggering

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Chenying; Wang, Zufei; Ji, Jiansong; Wang, Hailin; Hu, Xianghua; Chen, Chunmiao [Department of Radiology, Lishui Central Hospital, The Fifth Affiliated Hospital of Wenzhou Medical College, Lishui, Zhejiang 323000 (China)

    2015-11-01

    To assess the effect of chest circumference-adapted scanning protocol on radiation exposure and image quality in patients undergoing prospective electrocardiogram (ECG)-triggered coronary CT angiography (CCTA). One hundred-eighty-five consecutive patients, who had undergone prospective ECG triggering CCTA with a 128-slice CT, were included in the present study. Nipple-level chest circumference, body weight and height were measured before CT examinations. Patients were divided into four groups based on kV/ref·mAs = 100/200, 100/250, 120/200, and 120/250, when patient's chest circumference was ≤ 85.0 (n = 56), 85.0-90.0 (n = 53), 90.0-95.0 (n = 44), and > 95.0 (n = 32), respectively. Image quality per-segment was independently assessed by two experienced observers. Image noise and attenuation were also measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The effective radiation dose was calculated using CT dose volume index and the dose-length product. A significant correlation was observed between patients' chest circumference and body mass index (r = 0.762, p < 0.001). Chest circumference ranged from 74 to 105 cm, and the mean effective radiation dose was 1.9-3.8 mSv. Diagnostic image quality was obtained in 98.5% (2440/2478) of all evaluated coronary segments without any significant differences among the four groups (p = 0.650). No significant difference in image noise was observed among the four groups (p = 0.439), thus supporting the validity of the chest circumference-adapted scanning protocol. However, vessel attenuation, SNR and CNR were significantly higher in the 100 kV groups than in the 120 kV groups (p < 0.05). A measure of chest circumference can be used to adapt tube voltage and current for individualized radiation dose control, with resultant similar image noise and sustained diagnostic image quality.

  4. The Efficacy of Iopamidol (Pamiray 370) in Aortic and Extremity CT Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoo Jin; Lee, Jong Min; Lee, Hui Joong; Park, Ji Won [Kyungpook National University Hospital, Daegu (Korea, Republic of)

    2010-01-15

    To evaluate the clinical safety and radiological feasibility of a domestic iopamidol-based contrast media (Pamiray 370) during an aortic and extremity CT angiography. Between August and December of 2008, 100 patients (M:F=51:49; mean age, 59 years) underwent an aortic and extremity CT angiography using Pamiray 370 based with informed consent. All changes in vital signs, clinical symptoms, and adverse reactions to the contrast media were monitored. Two radiologists assessed the image quality of the CT angiography. A statistical comparison was conducted using an independent t-test and a Mann-Whitney test based on the 100-patient group studied using Optiray 350. The contrast enhancement of the descending aorta in the arterial phase showed a statistically greater efficacy (p<0.001) of Pamiray 370 compared to Optiray 350, which was the routine contrast media for CT angiography for our institute. Adverse reaction signs were evident in 3%(3/100) of the subjects. All of them showed mild and transient reactions such as vomiting (n=2) and coughing (n=1), with no medical treatment required. Contrast media related symptoms including dizziness (n=7), nausea (n=3), headaches (n=2), and injection site pain (n=1), were noted in 12%(12/100). The clinical efficacy of Pamiray 370 was acceptable for the aortic and extremity CT angiography, in terms of clinical safety, tolerance, and image quality.

  5. Reliability of visual assessment of non-contrast CT, CT angiography source images and CT perfusion in patients with suspected ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Tom van Seeters

    Full Text Available BACKGROUND AND PURPOSE: Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA rule and the Alberta Stroke Program Early CT Score (ASPECTS for different CT modalities in patients suspected of acute ischemic stroke. METHODS: We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement. RESULTS: Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps. Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps. CONCLUSION: Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging.

  6. Persistent hypoglossal artery and its variants diagnosed by CT and MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Uchino, Akira; Saito, Naoko; Okada, Yoshitaka; Kozawa, Eito; Nishi, Naoko; Mizukoshi, Waka; Inoue, Kaiji; Nakajima, Reiko; Takahashi, Masahiro [Saitama Medical University International Medical Center, Department of Diagnostic Radiology, Hidaka, Saitama (Japan)

    2013-01-15

    Persistent hypoglossal artery (PHA) is the second most common anastomosis between the carotid and vertebrobasilar systems and demonstrates some variations. We evaluated the prevalence of PHA on computed tomography (CT) angiography. We also evaluated characteristic features of PHA and its variants on magnetic resonance (MR) angiography. We retrospectively reviewed our database of 2,074 CT angiographic images obtained using either of two 64-slice multidetector CT scanners. We also reviewed our database of 7,646 MR angiographic images obtained using either of two 1.5-T or one 3.0-T imager. We could not determine the exact number of patients whose MR angiography included the hypoglossal canal. Most patients had or were suspected of having cerebrovascular diseases. We found six usual PHAs arising from the cervical internal carotid artery on CT angiography among 2,074 patients. On MR angiography, we also found six additional usual PHAs (total 12, right/left = 6/6, male/female = 3/9), three right PHAs originating from the external carotid artery (ECA), and two posterior inferior cerebellar arteries (PICAs) arising from the ECA without connection to the vertebral artery. The prevalence of usual PHA diagnosed by CT angiography was 0.29 %, slightly higher than that reported for angiography and may be due to selection bias in the examined patients. We propose naming usual PHA ''type 1 PHA''; PHA originating from the ECA, of which we found three, ''type 2 PHA''; and PICA arising from the ECA, of which we found two, ''type 2 PHA variant''. (orig.)

  7. Preoperative evaluation of the artery of adamkiewicz by MR angiography and CT angiography in patients with a thoracic aortic aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Niinuma, Hiroyuki; Ohira, Atsushi; Makita, Shinji; Moriai, Yoshiteru; Hiramori, Katsuhiko [Iwate Medical Univ., Morioka (Japan). School of Medicine; Yoshioka, Kunihiro; Nakajima, Takayuki; Kawazoe, Kohei [Iwate Medical Univ., Morioka (Japan). Memorial Heart Center

    2002-08-01

    Paraplegia is known as an extremely serious and important complication of surgical repair in patients with a thoraco-abdominal aortic aneurysm. It is important to evaluate the artery of Adamkiewicz (AdA) before surgical repair to prevent paraplegia. But the AdA is difficult to visualize by the invasive and hazardous, conventional selective angiography. The aim of this study was to visualize AdA by MR angiography (MRA) and CT angiography (CTA). Twenty-one consecutive patients with a thoracic aortic aneurysm underwent both gadolinium-enhanced, three-dimensional MRA and CTA using multislice helical CT. The AdA was successfully visualized in 15 of the 21 patients (71.4%) by MRA, and in 17 of those 21 patients (80.9%) by CTA. Its continuity was depicted in 12 of 15 patients (80%) by MRA, and in 9 of 17 patients (47%) by CTA. AdA was visualized at 85.7% by MRA or CTA, respectively. This study shows that CTA is a much more sensitive method to detect AdA than MRA. On the other hand, MRA is better to evaluate the continuity of AdA from the descending aorta to the anterior spinal artery, than CTA. Therefore, MRA and CTA are both useful for a preoperative evaluation of AdA and its detailed vascular anatomy from the aorta to the anterior spinal artery. (author)

  8. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  9. Cerebral artery evaluation of dual energy CT angiography with dual source CT

    Institute of Scientific and Technical Information of China (English)

    MA Rui; LIU Cheng; DENG Kai; SONG Shao-juan; WANG Dao-ping; HUANG Ling

    2010-01-01

    Background Conventional computed tomography angiography (CTA) is time consuming, user-dependent and has poor image quality in skull base region. This study assessed the feasibility of a new method, dual energy CTA for depicting the cerebral artery.Methods Phantom scan was done with head CTA sequences on dual source CT and 64 spiral CT for radiation dose calculation. Dual energy CTA was done with dual source CT on 36 patients who were suspected of having cerebral vascular disease. Three series axial images in 0.75 mm thick, 0.4 mm increment were acquired, which were named with 80 kV, 140 kV and merged images; 80 kV and 140 kV images were transferred into dual energy software, and maximum intensity projection (MIP) image was generated quickly by dual energy bone remove (DEBR group); merged images were transferred into In Space software to acquire MIP image through manual conventional bone remove (CoBR group). Post processing time and reading time were compared. Image qualities of the two groups were compared, mainly focusing on skull base segments of internal carotid artery and bone subtraction. ANOVA and SNK tests were applied for radiation dose comparison. Student's t test and Wilcoxon rank sum test were applied for assessing differences between data for significance. Cohen's kappa was used for interobserver agreement. Results Radiation dose of phantom scan showed dual energy CTA was between digital bone subtraction and conventional CTA. The post processing time and reading time were much shorter in DEBR than CoBR, and image quality in skull base was much higher in DEBR than CoBR (P0.5). Interobserver agreement for all vessel segments was excellent (kappa=0.97). Conclusions Dual energy CTA is a reliable, new modality for depicting cerebral artery, overcoming the limitation of conventional CTA in the skull base region. It can save much time in post processing and reading than conventional CTA.

  10. Diagnostic performance of CT angiography in neck vessel trauma: systematic review and meta-analysis.

    Science.gov (United States)

    Morales-Uribe, Carlos; Ramírez, Ana; Suarez-Poveda, Tatiana; Ortiz, Margarita; Sanabria, Alvaro

    2016-10-01

    This study was conducted in order to define the diagnostic performance of CT angiography for vascular injuries compared with angiography in patients with neck trauma. CT angiography is the cornerstone of diagnosis for hemodynamically stable patients with wounds suspicious of vascular trauma in the limbs, chest, or abdomen. Available evidence for the use of CT angiography in neck vascular trauma comes from small case series and few randomized controlled trials, and high-quality information does not exist regarding its performance. A protocol using the recommendations of the Cochrane Collaboration was designed. A systematic search of diagnostic studies without limits on language or time was carried out to December 2014. Studies including patients with neck trauma with retrospective or prospective data collection that assessed CT angiography compared with other methods were selected. Methodological quality was assessed using the QUADAS-2 tool. A hierarchical model ROC curve and a bivariate random effects model were used for the pooled analysis. Sixteen studies were selected and reviewed, and nine studies with 693 patients were included in this review. The overall sensitivity was 97 % (95 % CI 0.77-1.00; I (2) = 65.7 % (41.4-90.0)), while the overall specificity was 99 % (95 % CI 0.93-1.00; I (2) = 0). The hierarchic ROC curve showed an area under the curve of 0.99. Publication bias was not identified in this study. CT angiography can be stated as the gold standard for diagnosing vascular injuries in hemodynamically stable patients with neck trauma.

  11. A newly developed technique involving the optimization of flow velocity compensation for lower extremity CT angiography

    Institute of Scientific and Technical Information of China (English)

    ZHANG Lei; XU Dong; LI KunCheng; JIN ErHu; BARNES Bret

    2013-01-01

    Advanced computed tomography (CT) technology has allowed for faster and more robust imaging.However,it has been a technical challenge to correctly synchronize CT acquisition with adequate and uniform arterial enhancement in the entire peripheral arterial tree.In this summary,we introduce a method of injection/acquisition optimization strategy based on a velocity-compensated CT angiography technique for the peripheral artery system,which is currently used in the United States.We believe that this imaging technique will provide additional information for our daily CT services in China.

  12. Whole-brain dynamic CT angiography and perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Orrison, W.W. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Department of Medical Education, University of Nevada School of Medicine, Reno, NV (United States); Snyder, K.V.; Hopkins, L.N. [Department of Neurosurgery, Millard Fillmore Gates Circle Hospital, Buffalo, NY (United States); Roach, C.J. [School of Life Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Ringdahl, E.N. [Department of Psychology, University of Nevada Las Vegas, Las Vegas, NV (United States); Nazir, R. [Shifa International Hospital, Islamabad (Pakistan); Hanson, E.H., E-mail: eric.hanson@amigenics.co [College of Osteopathic Medicine, Touro University Nevada, Henderson, NV (United States); Department of Health Physics and Diagnostic Sciences, University of Nevada Las Vegas, Las Vegas, NV (United States); Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States)

    2011-06-15

    The availability of whole brain computed tomography (CT) perfusion has expanded the opportunities for analysing the haemodynamic parameters associated with varied neurological conditions. Examples demonstrating the clinical utility of whole-brain CT perfusion imaging in selected acute and chronic ischaemic arterial neurovascular conditions are presented. Whole-brain CT perfusion enables the detection and focused haemodynamic analyses of acute and chronic arterial conditions in the central nervous system without the limitation of partial anatomical coverage of the brain.

  13. Feasibility of low contrast media volume in CT angiography of the aorta

    NARCIS (Netherlands)

    Seehofnerová, Anna; Kok, Madeleine; Mihl, Casper; Douwes, Dave; Sailer, Anni; Nijssen, Estelle; de Haan, Michiel J W; Wildberger, Joachim E; Das, Marco

    2015-01-01

    OBJECTIVES: Using smaller volumes of contrast media (CM) in CT angiography (CTA) is desirable in terms of cost reduction and prevention of contrast-induced nephropathy (CIN). The purpose was to evaluate the feasibility of low CM volume in CTA of the aorta. METHODS: 77 patients referred for CTA of th

  14. Bilateral internal carotid agenesis: value of CT angiography and correlation to embryogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Pilleul, F.; Rouviere, O. [Dept. of Radiology, Hopital Edouard Herriot, Lyon (France); Guibaud, L.; Pracros, J.P. [Dept. of Pediatric Imaging, Hopital Debrousse, Lyon (France); Badinand, N. [Dept. of Pediatric Neurology, Hopital Debrousse, Lyon (France)

    2001-05-01

    Bilateral internal carotid artery agenesis is an uncommon disease, difficult to differentiate from bilateral carotid artery thrombosis. A few case reports have described the contribution of conventional angiogram to make the diagnosis and recognize the anatomic details of this rare malformation. Advantages of CT angiography as a non-invasive radiologic tool are discussed in this case report. (orig.)

  15. Quantitative analysis of arterial flow properties for detection of non-calcified plaques in ECG-gated coronary CT angiography

    Science.gov (United States)

    Wei, Jun; Zhou, Chuan; Chan, Heang-Ping; Chughtai, Aamer; Agarwal, Prachi; Kuriakose, Jean; Hadjiiski, Lubomir; Patel, Smita; Kazerooni, Ella

    2015-03-01

    We are developing a computer-aided detection system to assist radiologists in detection of non-calcified plaques (NCPs) in coronary CT angiograms (cCTA). In this study, we performed quantitative analysis of arterial flow properties in each vessel branch and extracted flow information to differentiate the presence and absence of stenosis in a vessel segment. Under rest conditions, blood flow in a single vessel branch was assumed to follow Poiseuille's law. For a uniform pressure distribution, two quantitative flow features, the normalized arterial compliance per unit length (Cu) and the normalized volumetric flow (Q) along the vessel centerline, were calculated based on the parabolic Poiseuille solution. The flow features were evaluated for a two-class classification task to differentiate NCP candidates obtained by prescreening as true NCPs and false positives (FPs) in cCTA. For evaluation, a data set of 83 cCTA scans was retrospectively collected from 83 patient files with IRB approval. A total of 118 NCPs were identified by experienced cardiothoracic radiologists. The correlation between the two flow features was 0.32. The discriminatory ability of the flow features evaluated as the area under the ROC curve (AUC) was 0.65 for Cu and 0.63 for Q in comparison with AUCs of 0.56-0.69 from our previous luminal features. With stepwise LDA feature selection, volumetric flow (Q) was selected in addition to three other luminal features. With FROC analysis, the test results indicated a reduction of the FP rates to 3.14, 1.98, and 1.32 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. The study indicated that quantitative blood flow analysis has the potential to provide useful features for the detection of NCPs in cCTA.

  16. Color-coded cerebral computed tomographic angiography: implementation of a convolution-based algorithm and first clinical evaluation in patients with acute ischemic stroke.

    Science.gov (United States)

    Thierfelder, Kolja M; Havla, Lukas; Beyer, Sebastian E; Ertl-Wagner, Birgit; Meinel, Felix G; von Baumgarten, Louisa; Janssen, Hendrik; Ditt, Hendrik; Reiser, Maximilian F; Sommer, Wieland H

    2015-05-01

    The objective of this study was to develop a new method of displaying dynamic cerebral computed tomographic (CT) angiography (CTA) data sets in which the time delay to maximum enhancement (Tdelay) is displayed in a range of colors (color-coded CT angiography [cCTA]). This institutional review board-approved study included multiparametric CT data sets from 16 patients with different types of supra-aortic large vessel occlusions. Color-coded CT angiography was reconstructed from CT perfusion raw data sets. All voxel enhancement curves were fitted to f(t) = α · AIFmtt(t - Δt), with AIFmtt(t), indicating enhancement of AIF dilated by convolution with boxcar function (with mean transit time [mtt]); α, scaling factor; and [INCREMENT]t, transition along the time. The time delay to maximum enhancement was defined as Tdelay = Δt +0.5 · mtt. Values of Tdelay were color-coded and superimposed on temporal maximum intensity projections CTA resulting in colored angiographic composite images. For a pilot clinical evaluation, diagnostic confidence in determining the pathology, quality of the visualization of leptomeningeal collaterals, and additional diagnostic information were assessed. The reconstruction of cCTA was technically feasible in all 16 patients. Both diagnostic confidence (P < 0.01) and the quality of the visualization of collaterals (P < 0.0001) were significantly higher when using the combination of single-phase CTA and cCTA compared with single-phase CTA alone. Additional diagnostic information was obtained with cCTA regarding occlusion type (reader 1: 5 cases and reader 2: 4 cases), differentiation between arteries and veins (11/13), differentiation between antegrade and retrograde filling (12/13), as well as leptomeningeal collateralization (13/14). Color-coded CT angiography is a technically feasible technique that provides additional information on cerebral hemodynamics in ischemic stroke patients.

  17. Preoperative planning for endovascular aortic repair of abdominal aortic aneurysms: feasibility of nonenhanced MR angiography versus contrast-enhanced CT angiography.

    Science.gov (United States)

    Goshima, Satoshi; Kanematsu, Masayuki; Kondo, Hiroshi; Kawada, Hiroshi; Kojima, Toshihisa; Sakurai, Kota; Watanabe, Haruo; Shimabukuro, Katsuya; Matsuno, Yukihiro; Ishida, Narihiro; Takemura, Hirofumi; Bae, Kyongtae T

    2013-06-01

    To compare vascular measurements to determine stent types and configurations for abdominal endovascular aneurysm repair (EVAR) by comparing results of contrast material-enhanced computed tomographic (CT) angiography and nonenhanced magnetic resonance (MR) angiography. This prospective study was institutional review board approved, and all patients provided written informed consent. Fifty patients (45 men and five women; mean age, 76.0 years) admitted for elective abdominal EVAR underwent preoperative abdominal CT angiography (triplanar reformatted images; section thickness of 1-3 mm) and nonenhanced MR angiography (triplanar two-dimensional single-shot turbo field-echo images; section thickness of 6 mm). Two observers independently completed standard measurement and device selection forms for endovascular stent planning for CT and MR angiography. Pearson and intraclass correlation coefficients were calculated to evaluate intermodality and interobserver differences. No significant difference was found in aortic neck diameter (observer 1: CT, 18.5 mm; MR, 19.0 mm; P = .43) (observer 2: CT, 19.6 mm; MR, 19.3 mm; P = .59), aortic neck diameter 15 mm distal to the lowest renal artery (observer 1: CT, 19.2 mm; MR, 19.2 mm; P = .38) (observer 2: CT, 19.6 mm; MR, 19.6 mm; P = .91), aortic neck length (observer 1: CT, 43.6 mm; MR, 43.6 mm; P = .85) (observer 2: CT, 44.4 mm; MR, 44.0 mm; P = .93), or other key vascular measurements (P = .23-.99) for preoperative planning. These included aneurysm diameter, lowest renal artery to aortic bifurcation length, aortic bifurcation diameter, common iliac artery diameters, external iliac artery diameters, length between orifices of lower renal and internal iliac arteries, and iliac artery sealing length. CT and MR angiography measurements showed very strong correlation (r = 0.92-0.99). Intraclass correlation coefficients between observers ranged from 0.90 to 0.98. Stent types and configurations determined with CT measurements remained

  18. Intravenous flat detector CT angiography for non-invasive visualisation of intracranial flow diverter: technical feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Struffert, Tobias; Saake, Marc; Ott, Sabine; Engelhorn, Tobias; Goelitz, Philipp; Kloska, Stephan; Doelken, Marc; Doerfler, Arnd [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany)

    2011-08-15

    To demonstrate the feasibility of intravenous Flat Detector CT Angiography (FD-CTA) for visualisation of intracranial Flow Diverting Devices. Flow Diverting Devices are used increasingly for treatment of intracranial aneurysms. A close follow up is necessary because it becomes obvious that a significant proportion of aneurysms treated with these devices remain patent. A minimally invasive method is highly desirable. In two patients treated with flow diverters a Flat Detector CT (FD-CT) with intravenous contrast medium application was performed. Post-processing was performed using commercially available software. In both patients the lumen of the device and the lumen of the aneurysm could be clearly evaluated. Some beam hardening artefacts due to the marker wires of the device were obvious. Flat Detector CT with intravenous contrast material application to evaluate flow-diverting devices seems to be feasible. Further studies are necessary to perform comparative evaluation of FD-CTA with angiography and other techniques like MRA or conventional CT angiography. (orig.)

  19. Three-dimensional CT angiography with volume rendering for the dignosis of multiple intracranial aneurysms

    Institute of Scientific and Technical Information of China (English)

    FANG Bing; LI Tie-lin; ZHANG Jian-min; DUAN Chuan-zhi; WANG Qiu-jing; ZAO Qing-ping

    2004-01-01

    Objective:To evaluate the importance of 3D-CTA with volume rendering for the diagnosis of multiple intracranial aneurysms. Methods: Axial source images were obtained by helical CT scanning and reconstruction of 3D-CTA images was done by volume rendering technique in conjunction with multiplanar reformation. Results: In the past one year,there were 10 patients diagnosed as having multiple intracranial aneurysms by 3D-CTA and altogether 24 aneurysms were visualized,including 10 small aneurysms(≤5mm.Three dimensional CT angiography with volume rendering demonstrated aneurysms very well and provided useful information concerning the site,shape,size and spatial relationship with the surrounding vessels and bone anatomy. Conclusion: Three-dimensional CT angiography with volume rendering is a quick,reliable,and relatively noninvasive method for diagnosing multiple intracranial aneurysms.It delineates detailed aneurysmal morphology,and provides useful information for planning microsurgical approaches.

  20. Detection of hemorrhage source: the diagnostic value of post-mortem CT-angiography.

    Science.gov (United States)

    Palmiere, C; Binaghi, S; Doenz, F; Bize, P; Chevallier, C; Mangin, P; Grabherr, S

    2012-10-10

    The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

  1. Incremental prognostic value of coronary computed tomographic angiography over coronary artery calcium score for risk prediction of major adverse cardiac events in asymptomatic diabetic individuals

    NARCIS (Netherlands)

    J.K. Min (James); T.M. LaBounty (Troy); M. Gomez (Millie); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); M.J. Budoff (Matthew); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); V.Y. Cheng (Victor); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); A.M. Dunning (Allison); G.M. Feuchtner (Gudrun); M. Hadamitzky (Martin); J. Hausleiter (Jörg); P.A. Kaufmann (Philipp); Y-J. Kim (Yong-Jin); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); D.S. Berman (Daniel)

    2014-01-01

    textabstractBackground: Coronary artery disease (CAD) diagnosis by coronary computed tomographic angiography (CCTA) is useful for identification of symptomatic diabetic individuals at heightened risk for death. Whether CCTA-detected CAD enables improved risk assessment of asymptomatic diabetic indiv

  2. Incremental prognostic value of coronary computed tomographic angiography over coronary artery calcium score for risk prediction of major adverse cardiac events in asymptomatic diabetic individuals

    NARCIS (Netherlands)

    J.K. Min (James); T.M. LaBounty (Troy); M. Gomez (Millie); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); M.J. Budoff (Matthew); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); V.Y. Cheng (Victor); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); A.M. Dunning (Allison); G.M. Feuchtner (Gudrun); M. Hadamitzky (Martin); J. Hausleiter (Jörg); P.A. Kaufmann (Philipp); Y-J. Kim (Yong-Jin); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); D.S. Berman (Daniel)

    2014-01-01

    textabstractBackground: Coronary artery disease (CAD) diagnosis by coronary computed tomographic angiography (CCTA) is useful for identification of symptomatic diabetic individuals at heightened risk for death. Whether CCTA-detected CAD enables improved risk assessment of asymptomatic diabetic indiv

  3. Prevalence of non-cardiovascular findings on CT angiography in children with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Malik, Archana [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); St. Christopher' s Hospital for Children, Department of Radiology, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); New York Cardiovascular Institute at Lenox Hill Radiology, New York, NY (United States); Servaes, Sabah; Keller, Marc S. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Schwartz, Mathew C. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Levine Children' s Hospital, Sanger Heart and Vascular Institute, Charlotte, NC (United States); Epelman, Monica [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Nemours Children' s Health System/Nemours Children' s Hospital, Department of Medical Imaging/Radiology, Orlando, FL (United States)

    2017-03-15

    CT angiography is gaining broader acceptance in the evaluation of children with known or suspected congenital heart disease. These studies include non-cardiovascular structures such as the mediastinum, lung parenchyma and upper abdominal organs. It is important to inspect all these structures for potential abnormalities that might be clinically important and, in some cases, may impact care plans. To determine the prevalence of non-cardiovascular findings in CT angiography of children with congenital heart disease. During 28 months, 300 consecutive children (170 males; mean age: 7.1 years, age range: 6 h-26 years), referred from a tertiary pediatric cardiology center, underwent clinically indicated CT angiography to evaluate known or suspected congenital heart disease. Slightly more than half (n = 169) of the patients were postoperative or post-intervention. Examinations were retrospectively reviewed, and non-cardiovascular findings were recorded and tabulated by organ system, congenital heart disease and operative procedure in conjunction with outcomes from medical charts. Non-cardiovascular findings were identified in 83% (n = 250 / 300) of the studies for a total of 857 findings. In 221 patients (n = 73.7% of 300) a total of 813 non-cardiovascular findings were clinically significant, while in 9.7% (n = 29 / 300) of patients, 5.1% (n = 44 / 857) of the findings were nonsignificant. In 38.3% (n = 115 / 300) of patients with significant non-cardiovascular pathology, the findings were unexpected and directly impacted patient care plans. Commonly involved organs with non-cardiovascular findings were the lungs with 280 non-cardiovascular findings in 176 / 300 (58.7%) of patients, the airway with 139 non-cardiovascular findings in 103 / 300 (34.3%) of patients and the liver with 108 non-cardiovascular findings in 72 / 300 (24.0%) of patients. Syndromic associations were noted in 22% (n = 66 / 300) of the patients. Non-cardiovascular findings are common in children with

  4. CT coronary angiography in patients with atrial fibrillation; CT-Koronarangiographie bei Patienten mit Vorhofflimmern

    Energy Technology Data Exchange (ETDEWEB)

    Kovacs, A.; Sommer, T.; Leiss, A.; Naehle, P.; Schild, H.; Flacke, S. [Universitaetsklinikum Bonn, Radiologische Klinik (Germany); Probst, C.; Welz, A. [Universitaetsklinikum Bonn, Klinik fuer Herzchirurgie (Germany)

    2005-12-15

    Purpose: Reliable visualization of the coronary arteries with multislice spiral CT angiography (MSCTA) in patients with atrial fibrillation (AF) remains a challenge despite retrospective ECG gating. A recently developed new algorithm automatically compensates dynamic changes in the heart rate during the scan, thus reducing misregistration and motion artifacts. The HeartBeat-RT algorithm combines a fixed percent delay determined from the first R wave and the fixed offset delay based on the second R wave in the ECG cycle. The purpose of this study was to find out the optimal reconstruction window in MSCTA in patients with AF for each of the three major coronary arteries during the cardiac cycle. Materials and methods: 20 patients with permanent AF were imaged on a 16-slice scanner (slice collimation: 16 x 0.75 mm; rotation time 0.42 s; 140 kV; 380 mAs; 120 ml Ultravist 370 {sup registered} i.v.). The patients had not received any previous drugs for heart frequency regulation. Acquisition was started after bolus tracking of a biphasic bolus of 120 ml Ultravist 370 injected intravenously. Each coronary segment was reconstructed at 0%-90% of the cardiac cycle in increments of 10%. For image analysis we used coronary segments as defined by the American Heart Association. Two blinded independent readers assessed the image quality in terms of visibility and artifacts (five-point rating scale 1=very poor, 2=poor, 3=fair, 4=good and 5=excellent) and the degree of stenosis (five-point rating scale 1=0%, 2=1%-49%, 3=50%-74%, 4=75%-99%, 5=100%) on axial slices, multiplanar reconstructions and three-dimensional volume-rendered images. (orig.)

  5. Spiral-CT angiography after intraarterial iliac stent placement; Spiral-CT-Angiographie nach arterieller iliakaler Stentapplikation

    Energy Technology Data Exchange (ETDEWEB)

    Freund, M. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Palmie, S. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Wesner, F. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik; Heller, M. [Kiel Univ. (Germany). Klinik fuer Radiologische Diagnostik

    1995-10-01

    In a prospective study 32 patients underwent CT-A after stent placement in the iliac arteries. The vascular morphology was analyzed regarding neointimal hyperplasia and calcification pattern. The results were compared with those of clinical findings (walking distance), Doppler ultrasound (ankle-brachial index) and DSA. All 47 stents were visible and patent (100%). One misplacement was identified. A good correlation was found between an improved ankle-brachial index and CT-A (88.5%) and extension of the walking distance and CT-A (92.3%). Concerning location, number and grade of stenoses the results between CT-A and DSA matched in 42.1%. An exact mapping of calcified plaques was possible in all cases. (orig./MG) [Deutsch] Nach perkutaner transluminaler Angioplastie (PTA) und Stenteinlage wurden 32 Patienten prospektiv mittels CT-A untersucht. Es erfolgte eine Analyse der Gefaessmorphologie hinsichtlich neointimaler Hyperplasien und Verkalkungsmuster. Weiterhin wurden die Ergebnisse mit denen der intraarteriellen digitalen Subtraktionsangiographie (i.a. DSA), dem klinischen Befund (Gehstrecke) und der Doppler-Ultraschalluntersuchung (Arm-Knoechel-Index/AKI) verglichen. Alle 47 Stents konnten in der CT-A exakt lokalisiert und als offen identifiziert werden (100%). Eine Stentfehllage wurde diagnostiziert. Der Nachweis neointimaler Hyperplasie gelang aufgrund von Metallartefakten im Stentniveau nicht. Verkalkungen waren in allen Faellen nachweisbar. Eine Uebereinstimmung zwischen DSA und CT-A hinsichtlich des Schweregrades, der Anzahl und Lokalisation von Stenosen fand sich nur in 42,1%. In 88,5% der Faelle bestand eine Uebereinstimmung zwischen CT-morphologischem Befund und verbessertem AKI, in 92,3% mit verlaengerter Gehstrecke. (orig./MG)

  6. Prediction of outcome in patients with suspected acute ischaemic stroke with CT perfusion and CT angiography: the Dutch acute stroke trial (DUST) study protocol

    NARCIS (Netherlands)

    Seeters, T. van; Biessels, G.J.; Schaaf, I.C. van der; Dankbaar, J.W.; Horsch, A.D.; Luitse, M.J.; Niesten, J.M.; Mali, W.P.Th.; Kappelle, L.J.; Graaf, Y. van der; Velthuis, B.K.; Dijk, E.J. van

    2014-01-01

    BACKGROUND: Prediction of clinical outcome in the acute stage of ischaemic stroke can be difficult when based on patient characteristics, clinical findings and on non-contrast CT. CT perfusion and CT angiography may provide additional prognostic information and guide treatment in the early stage. We

  7. Evaluation of spinal cord vessels using multi-slice CT angiography

    Institute of Scientific and Technical Information of China (English)

    陈爽; 钱建国; 冯晓源

    2004-01-01

    @@ Compared with the large number of head and neck vascular studies, computer tomography (CT) angiography of spinal vascular lesions has received relatively little attention. Several series and a few isolated cases of spinal vascular malformations demonstrated with magnetic resonance (MR) angiography have been reported.1-3 Selective digital subtraction angiography (DSA) is gold standard for diagnosis of spinal vascular lesions.4 However, it is invasive, time consuming, expensive, and dependent on the skills of the operator. Based on the DSA appearance and the surgical findings, spinal vascular malformations are generally, although not universally, classified as intradural (intramedullary and/or extramedullary) arteriovenous malformation (AVM) or arteriovenous fistula (AVF), and dural AVF. Recommended treatments of dural AVF consist of surgical obliteration and/or embolization.5-8

  8. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  9. Stent fracture and longitudinal compression detected on coronary CT angiography in the first- and new-generation drug-eluting stents.

    Science.gov (United States)

    Chung, Mi Sun; Yang, Dong Hyun; Kim, Young-Hak; Roh, Jae-Hyung; Song, Jihyun; Kang, Joon-Won; Ahn, Jung-Min; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Lee, Cheol Whan; Park, Seong-Wook; Park, Seung-Jung; Lim, Tae-Hwan

    2016-04-01

    To evaluated prevalence and clinical implication of stent fracture and longitudinal compression in first- and new-generation drug-eluting stents (DES) using coronary computed tomography angiography (CCTA). The incidence of stent fracture and longitudinal compression were compared between first- and new-generation DES in 374 patients who underwent coronary stenting using DES and follow-up CCTA due to recurrent angina. 235 and 139 patients received 322 first- and 213 new-generation DES, respectively. The crude per-stent incidence of longitudinal compression (6.1 vs. 0.3 %, p stent fracture (11.3 vs. 8.1 %, p = 0.23) was comparable. On follow-up coronary angiography for 347 stents, stent fracture (3.2 %) and longitudinal compression (0.9 %) were less detected than those on CCTA. Ostial stenting was a risk factor of longitudinal compression (p Stent fracture was associated with younger patients (p = 0.03), longer stent (p = 0.010), and excessively tortuous lesions (p = 0.001). The presence of stent fracture or longitudinal compression was not associated with poor clinical outcomes. The longitudinal compression more frequently occurred after new-generation DES implantation. The stent fracture was comparable between two DES. However, the occurrence of such mechanical deformities did not translate into a poor clinical outcome.

  10. Hybrid CT angiography and quantitative (15)O-water PET for assessment of coronary artery disease

    DEFF Research Database (Denmark)

    Thomassen, Anders; Petersen, Henrik; Diederichsen, Axel C P;

    2013-01-01

    CT angiography (CTA) can rule out significant stenoses with a very high reliability, whereas its ability to confirm significant stenoses is suboptimal. In contrast, measurements of myocardial blood flow (MBF) provide information on the haemodynamic consequences of stenoses. Therefore, a combinati...... of the two might improve diagnostic accuracy. We conducted a head-to-head comparison of CTA, measurement of MBF by (15)O-water PET, and hybrid PET/CTA for the detection of significant coronary artery stenoses....

  11. Diagnosis of Persistent Primitive Olfactory Artery Using CT Angiography: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Yeo, Soo Hyun; Rho, Byung Hak; Kim, Eal Maan; Chang, Hyuk Won [Keimyung University College of Medicine, Daegu (Korea, Republic of); Sohn, Chul Ho [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2009-09-15

    A persistent primitive olfactory artery is a rare vascular anomaly and is incidentally found without any associated symptom for the most part. However, it has clinical significance in view of its high association with the development of cerebral aneurysms occurring at the hairpin turn. We present a case of a persistent primitive olfactory artery incidentally diagnosed by a CT angiography as well as a literature review of related previous articles

  12. Arteriovenous fistula complicating iliac artery pseudo aneurysm: diagnosis by CT angiography.

    Science.gov (United States)

    Huawei, L; Bei, D; Huan, Z; Zilai, P; Aorong, T; Kemin, C

    2002-01-01

    Fistula formation to the inferior vena cava is a rare complication of aortic aneurysm which is often misdiagnosed clinically. In one hundred of reported arteriocaval fistulae, none was originating from the right common iliac artery. We report a case of ileo-caval fistula due to a iatrogenic pseudoaneurysm. High resolution 3D imaging using breath-hold CT angiography is highly specific in identifying the location, extent of the aortocaval fistula as well as the neighbouring anatomic structures.

  13. Diagnostic accuracy of 64 multislice CT angiography in the assessment of coronary in-stent restenosis: A meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sun Zhonghua [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, WA (Australia)], E-mail: z.sun@curtin.edu.au; Almutairi, Abdulrahman Marzouq D. [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, Perth, WA (Australia)

    2010-02-15

    Purpose: The aim of this study was to perform a meta-analysis of the diagnostic accuracy of 64-slice CT angiography for the detection of coronary in-stent restenosis in patients treated with coronary stents when compared to conventional coronary angiography. Materials and methods: A search of PUBMED/MEDLINE, ProQuest and Cochrane library databases for English literature was performed. Only studies comparing 64-slice CT angiography with conventional coronary angiography for the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model. Results: Fourteen studies met selection criteria for inclusion in the analysis. The mean value of assessable stents was 89%. Prevalence of in-stent restenosis following coronary stenting was 20% among these studies. Pooled estimates of the sensitivity and specificity of overall 64-slice CT angiography for the detection of coronary in-stent restenosis was 90% (95% CI: 86%, 94%) and 91% (95% CI: 90%, 93%), respectively, based on the evaluation of assessable stents. Diagnostic value of 64-slice CT angiography was found to decrease significantly when the analysis was performed with inclusion of nonassessable segments in five studies, with pooled sensitivity and specificity being 79% (95% CI: 68%, 88%) and 81% (95% CI: 77%, 84%). Stent diameter is the main factor affecting the diagnostic value of 64-slice CT angiography. Conclusion: Our results showed that 64-slice CT angiography has high diagnostic value (both sensitivity and specificity) for detection of coronary in-stent restenosis based on assessable segments when compared to conventional coronary angiography.

  14. Multilevel segmentation of intracranial aneurysms in CT angiography images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yan [Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, California 94122 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Zhang, Yue, E-mail: y.zhang525@gmail.com [Veterans Affairs Medical Center, San Francisco, California 94121 and University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France); Navarro, Laurent [Ecole Nationale Superieure des Mines de Saint-Etienne, Saint-Etienne 42015 (France); Eker, Omer Faruk [CHU Montpellier, Neuroradiologie, Montpellier 34000 (France); Corredor Jerez, Ricardo A. [Ecole Polytechnique Federale de Lausanne, Lausanne 1015 (Switzerland); Chen, Yu; Zhu, Yuemin; Courbebaisse, Guy [University of Lyon, CREATIS, CNRS UMR 5220, INSERM U1206, UCB Lyon1, INSA Lyon, Lyon 69100 (France)

    2016-04-15

    Purpose: Segmentation of aneurysms plays an important role in interventional planning. Yet, the segmentation of both the lumen and the thrombus of an intracranial aneurysm in computed tomography angiography (CTA) remains a challenge. This paper proposes a multilevel segmentation methodology for efficiently segmenting intracranial aneurysms in CTA images. Methods: The proposed methodology first uses the lattice Boltzmann method (LBM) to extract the lumen part directly from the original image. Then, the LBM is applied again on an intermediate image whose lumen part is filled by the mean gray-level value outside the lumen, to yield an image region containing part of the aneurysm boundary. After that, an expanding disk is introduced to estimate the complete contour of the aneurysm. Finally, the contour detected is used as the initial contour of the level set with ellipse to refine the aneurysm. Results: The results obtained on 11 patients from different hospitals showed that the proposed segmentation was comparable with manual segmentation, and that quantitatively, the average segmentation matching factor (SMF) reached 86.99%, demonstrating good segmentation accuracy. Chan–Vese method, Sen’s model, and Luca’s model were used to compare the proposed method and their average SMF values were 39.98%, 40.76%, and 77.11%, respectively. Conclusions: The authors have presented a multilevel segmentation method based on the LBM and level set with ellipse for accurate segmentation of intracranial aneurysms. Compared to three existing methods, for all eleven patients, the proposed method can successfully segment the lumen with the highest SMF values for nine patients and second highest SMF values for the two. It also segments the entire aneurysm with the highest SMF values for ten patients and second highest SMF value for the one. This makes it potential for clinical assessment of the volume and aspect ratio of the intracranial aneurysms.

  15. CT pulmonary angiography: increasingly diagnosing less severe pulmonary emboli.

    Directory of Open Access Journals (Sweden)

    Andrew J Schissler

    Full Text Available BACKGROUND: It is unknown whether the observed increase in computed tomography pulmonary angiography (CTPA utilization has resulted in increased detection of pulmonary emboli (PEs with a less severe disease spectrum. METHODS: Trends in utilization, diagnostic yield, and disease severity were evaluated for 4,048 consecutive initial CTPAs performed in adult patients in the emergency department of a large urban academic medical center between 1/1/2004 and 10/31/2009. Transthoracic echocardiography (TTE findings and peak serum troponin levels were evaluated to assess for the presence of PE-associated right ventricular (RV abnormalities (dysfunction or dilatation and myocardial injury, respectively. Statistical analyses were performed using multivariate logistic regression. RESULTS: 268 CTPAs (6.6% were positive for acute PE, and 3,780 (93.4% demonstrated either no PE or chronic PE. There was a significant increase in the likelihood of undergoing CTPA per year during the study period (odds ratio [OR] 1.05, 95% confidence interval [CI] 1.04-1.07, P<0.01. There was no significant change in the likelihood of having a CTPA diagnostic of an acute PE per year (OR 1.03, 95% CI 0.95-1.11, P = 0.49. The likelihood of diagnosing a less severe PE on CTPA with no associated RV abnormalities or myocardial injury increased per year during the study period (OR 1.39, 95% CI 1.10-1.75, P = 0.01. CONCLUSIONS: CTPA utilization has risen with no corresponding change in diagnostic yield, resulting in an increase in PE detection. There is a concurrent rise in the likelihood of diagnosing a less clinically severe spectrum of PEs.

  16. Efficiency of ultrasonography and CT angiography in follow-up studies of carotid stent and percutaneous transluminal angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Chang Woo; Lee, Byung Hee; Chung, Bong Sub; Ahn, Jung Yong; Heo, Kyung; Kho, Young Sik [Pundang CHA General Hospital, Pochon CHA Univ. College of Medicine, Pochon (Korea, Republic of)

    1999-12-01

    The aim of this study was to determine a more appropriate method for follow-up of carotid stenting by comparing the efficiency of US and CT angiography. Eleven carotid arteries of seven patients(men:5, women:2, mean age:56.4years) who underwent stent placement and percutaneous transluminal angioplasty(PTA) because of carotid stenosis were studied. The follow-up periods ranged from three to eleven (mean, five) months, and US and CT angiography were performed in one day. Color duplex sonography was performed with a 10 MHz linear array transducer. After spiral CT scan were obtained, MPR images were reconstructed on a workstation. Retrospective imaging analysis specifically focused on [1] stent configuration, [2] the accuracy of internal diameter measurement, [3] the detection of blood flow and the measurement of blood flow velocity, [4] the presence of atheroma and intraluminal thrombi, [5] the measurement of stent location, and [6] artifacts. US was more accurate than CT angiography for measuring internal diameter. In all cases, US and CT angiography were able to detect the blood flow at carotid artery, and utilizing the Doppler spectrum, flow velocity was measured. US showed atheromas in all cases but CT angiography demonstrated calcified atheromas in three cases only. In six cases, US failed to determine stent location, though in this respect CT angiography was successful in all cases. Artifacts of US were small reverberation artifact(11/11) of the stent and a defective color Doppler signal caused by acoustic shadowing of atheroma calcification(3/11). Artifacts of CT angiogrpahy were hardbeam artifact of the stent(11/11) and motion artifact(3/11). US was superior to CT angiography in accuracy of measuring stent diameter, hemodynamic assessment, high-resolution views of the luminal state of the stent and minimal artifacts for the non-invasive follow-up studies of carotid stenting.

  17. Multi-detector CT angiography for lower gastrointestinal bleeding: Can it select patients for endovascular intervention?

    Science.gov (United States)

    Foley, P T; Ganeshan, A; Anthony, S; Uberoi, R

    2010-02-01

    This is a retrospective review of the results at our institution of using multi-detector CT angiography (CTA) to localise lower gastrointestinal (GI) bleeding. We hypothesised that in our patient population: (i) CTA was unlikely to demonstrate bleeding in patients who were haemodynamically stable; (ii) in haemodynamically unstable patients in whom CTA was undertaken, the results could be used to select patients who would benefit from catheter angiography; and (iii) in haemodynamically unstable patients in whom CTA was undertaken, a subgroup of patients could be identified who would benefit from primary surgical treatment, avoiding invasive angiography completely. A retrospective review was conducted of the clinical records of all patients undergoing CTA for lower GI haemorrhage at our institution between 1 January 2005 and 30 June 2007. Out of the 20 patients examined, 10 had positive CTAs demonstrating the bleeding site. Nine were haemodynamically unstable at the time of the study. Four patients with positive CT angiograms were able to be treated directly with surgery and avoided invasive angiography. Ten patients had negative CTAs. Four of these were haemodynamically unstable, six haemodynamically stable. Only one required intervention to secure haemostasis, the rest stopped spontaneously. No haemodynamically stable patient who had a negative CTA required intervention. CTA is a useful non-invasive technique for localising the site of lower GI bleeding. In our patient population, in the absence of haemodynamic instability, the diagnostic yield of CTA was low and bleeding was likely to stop spontaneously. In haemodynamically unstable patients, a positive CTA allowed patients to be triaged to surgery or angiography, whereas there was a strong association between a negative CTA and spontaneous cessation of bleeding.

  18. Peripheral arterial occlusive disease: diagnostic performance and effect on therapeutic management of 64-section CT angiography.

    Science.gov (United States)

    Napoli, Alessandro; Anzidei, Michele; Zaccagna, Fulvio; Cavallo Marincola, Beatrice; Zini, Chiara; Brachetti, Giulia; Cartocci, Gaia; Fanelli, Fabrizio; Catalano, Carlo; Passariello, Roberto

    2011-12-01

    To evaluate the diagnostic performance and effect on therapeutic management of 64-section computed tomographic (CT) angiography in the assessment of steno-occlusive disease in patients with peripheral arterial disease (PAD), with conventional digital subtraction angiography (DSA) as the reference standard. The study protocol was approved by the institutional review board, and written informed consent was obtained from all patients. A total of 212 patients with symptomatic PAD underwent CT angiography and subsequent DSA. For stenosis analysis (≥ 70% stenosis), the arterial bed was divided into 35 segments and evaluated by three readers. Interobserver agreement was determined with generalized κ statistics. Accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) were calculated. In addition, according to the TransAtlantic Inter-Society Consensus (TASC) Document on Management of Peripheral Arterial Disease guidelines, treatment recommendations based on CT angiographic and DSA findings were compared. McNemar test was used to prove significant differences between CT angiographic and DSA findings. A total of 7420 arterial segments were evaluated, with excellent agreement between readers (κ ≥ 0.928). On a segmental basis, both sensitivity and specificity for stenosis of 70% or more were at least 96% (3072 of 3113 segments and 4141 of 4279 segments, respectively), with an accuracy of 98% (7213 of 7392 segments), a PPV of 96% (3072 of 3187 segments), an NPV of 99% (3141 of 3187 segments), a PLR of 36.7, and an NLR of 0.013. There was no significant difference between CT angiographic and DSA findings (P = .62-.87). In accordance with TASC II guidelines, 49 patients were referred for conservative treatment, 87 underwent endovascular procedures, 38 underwent surgery, and 17 received hybrid treatment. Therapy recommendations based on CT angiographic findings

  19. CT perfusion imaging and CT subtraction angiography in the diagnosis of ischemic cerebrovascular disease within 24 hours

    Institute of Scientific and Technical Information of China (English)

    管小亭; 于学英; 刘翔; 龙洁; 戴建平

    2003-01-01

    Objective To evaluate the value of the clinical use of CT perfusion imaging (CTPI) and CT subtraction angiography (CTSA) for diagnosing acute ischemic cerebrovascular disease (AICVD). Methods Twenty-four patients with AICVD onset within 24 hours were examined with regular CT, CTPI, and CTSA. Some cases received CTPI, magnetic resonance imaging (MRI), magnetic resonance angiography (MRA), digital subtraction angiography (DSA) or single photon emission computer tomography (SPECT) during follow-up examinations.Results Of the 24 cases, 11 had negative results from regular CT scans 3-6 hours after onset of stroke in 6 cases, 6-12 hours in 3 cases, and 12-24 hours in 2 cases. Ten of these cases were then confirmed by CTPI as having ischemic lesions, 2 with middle cerebral artery occlusion (MCAO), and 1 case with transient ischemic attack (TIA) with CTPI negative. Of the 24 cases, 13 had positive results from regular CT, 9 were diagnosed with ischemic lesions larger by using CTPI than regular CT, 1 case had MCAO and 1 had internal carotid artery occlusion (ICAO). There were 4 cases with ischemic lesions observed with regular CT having nearly the same range as that of lacunar infarctions using CTPI. Another 4 cases had more than 2 lesion areas. The peak time (PT), mean transit time (MTT) and relative flow (RF) of 24 cases were markedly different. The sides of ischemic lesions compared to each other and the core of the lesion compared to peripheral zones were also altered significantly (P<0.01).Conclusions Combined CTPI with CTSA can detect acute ischemic lesions at early and hyper-early stages and could distinguish between TIA, lacunar infarction and a larger area of infarction. Using semiquantitative blood perfusion analysis status, CTPI with CTSA could define position, area and range of the ischemic lesion and penumbra. These scans can also analyze the brain blood perfusion status. It is important to early diagnose the occlusion of the entire division of the internal

  20. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris

    Energy Technology Data Exchange (ETDEWEB)

    Pugliese, Francesca; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Mollet, Nico R.A.; deFeyter, Pim J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Runza, Giuseppe [University of Palermo, Department of Radiology, Palermo (Italy); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy); Mieghem, Carlos van; Meijboom, Willem B.; Baks, Timo [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); Malagutti, Patrizia [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands); University of Ferrara, Department of Cardiology, Ferrara (Italy); Cademartiri, Filippo [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Azienda Ospedaliera di Parma, Department of Radiology, Parma (Italy)

    2006-03-15

    Multislice computed tomography (CT) is an emerging technique for the non-invasive detection of coronary stenoses. While the diagnostic accuracy of 4-slice scanners was limited, 16-slice CT imagers showed promising results due to increased temporal and spatial resolution. These technical advances prompted us to evaluate the diagnostic performance of 64-slice CT coronary angiography in the detection of significant stenoses (defined as {>=} 50% luminal diameter reduction) versus invasive quantitative coronary angiography (QCA). Thirty-five patients with stable angina pectoris underwent CT coronary angiography performed with a 64-slice scanner (gantry rotation time 330 ms, individual detector width 0.6 mm) prior to conventional coronary angiography. Patients with heart rates >70 beats/min received 100 mg metoprolol orally. One hundred millilitres of contrast agent with an iodine concentration of 400 mgl/ml were injected at a rate of 5 ml/s into the antecubital vein. The CT scan was triggered with the bolus tracking technique. The sensitivity, specificity and the positive and negative predictive values of 64-slice CT were 99%, 96%, 78% and 99%, respectively, on a per-segment basis. The values obtained on a per-patient basis were 100%, 90%, 96% and 100%, respectively. When referral to catheterisation is questionable, CT coronary angiography may identify subjects with normal angiograms and consistently decrease the number of unnecessary invasive procedures. (orig.)

  1. Use of coronary CT angiography in the diagnosis of patients with suspected coronary artery disease: findings and clinical indications

    Institute of Scientific and Technical Information of China (English)

    Zhong-Hua Sun; Yu-Pin Liu; Dong-Jin Zhou; Yan Qi

    2012-01-01

    Objective To investigate the clinical applications of coronary CT angiography in patients with suspected coronary artery disease and identify factors that affect CT findings. Methods Medical records of patients suspected of coronary artery disease over a period of 12 months from a tertiary teaching hospital were retrospectively reviewed. Patient age, sex (male/female), duration of symptoms and abnormal rates of coronary CT angiography scans were analysed to investigate the relationship among these parameters. The patients by age were duration of symptoms was also classified into five groups: less than one week, one week to one month, one to three months, three to six months and more than six months. Results Of the 880 patient records reviewed, 800 met the above study criteria. Five hundred and forty nine patients demonstrated abnormal CT findings (68.6%). There was no significant difference in the percentage of abnormal CT findings based on patient sex and the duration of symptoms (P = 0.14). The abnormal rates of coronary CT angiography, however, increased significantly with increasing age (P < 0.001); with patients over 65 years of age 2.5 times more likely to have an abnormal CT scan relative to a patient under 45 years. A significant difference was found between abnormal coronary CT angiography and the duration of symptoms (P = 0.012). Conclusions Our results indicate coronary CT angiography findings are significantly related to the patient age group and duration of symptoms. Clinical referral for coronary CT angiography of patients with suspected coronary artery disease needs to be justified with regard to the judicious use of this imaging modality.

  2. Multidetector CT angiography in acute gastrointestinal bleeding: why, when, and how.

    Science.gov (United States)

    Geffroy, Yann; Rodallec, Mathieu H; Boulay-Coletta, Isabelle; Jullès, Marie-Christine; Fullès, Marie-Christine; Ridereau-Zins, Catherine; Zins, Marc

    2011-01-01

    Acute gastrointestinal (GI) bleeding remains an important cause of emergency hospital admissions, with substantial related morbidity and mortality. Bleeding may relate to the upper or lower GI tract, with the dividing anatomic landmark between these two regions being the ligament of Treitz. The widespread availability of endoscopic equipment has had an important effect on the rapid identification and treatment of the bleeding source. However, the choice of upper or lower GI endoscopy is largely dictated by the clinical presentation, which in many cases proves misleading. Furthermore, there remains a large group of patients with negative endoscopic results or failed endoscopy, in whom additional techniques are required to identify the source of GI bleeding. Multidetector computed tomography (CT) with its speed, resolution, multiplanar techniques, and angiographic capabilities allows excellent visualization of both the small and large bowel. Multiphasic multidetector CT allows direct demonstration of bleeding into the bowel and is helpful in the acute setting for visualization of the bleeding source and its characterization. Thus, multidetector CT angiography provides a time-efficient method for directing and planning therapy for patients with acute GI bleeding. The additional information provided by multidetector CT angiography before attempts at therapeutic angiographic procedures leads to faster selective catheterization of bleeding vessels, thereby facilitating embolization. Supplemental material available at http://radiographics.rsna.org/lookup/suppl/doi:10.1148/rg.313105206/-/DC1.

  3. Correlation between abdominal perforator vessels identified with preoperative CT angiography and intraoperative fluorescent angiography in the microsurgical breast reconstruction patient.

    Science.gov (United States)

    Pestana, Ivo A; Zenn, Michael R

    2014-01-01

    CT angiography (CTA) has become a reliable method of perforator vessel identification. Indocyanine green fluorescent angiography (ICGLA) produces a real-time image of large- and small-caliber blood vessels. The aim of this prospective study was to compare ICGLA with CTA to evaluate its reliability of vessel identification and correlation to perforator vessel size and number determined preoperatively by CTA. The effect of both imaging techniques on flap design or intraoperative plan was also evaluated. Over a 1-year period, patients presenting for free-tissue transfer breast reconstruction underwent preoperative CTA mapping of abdominal perforators followed by intraoperative ICGLA. Using visualization software, scaling factors were calculated so CTA and ICGLA data could be compared. Eighteen patients (24 breast reconstructions) were included. Larger CTA perforator size was associated with larger actual size (P = 0.04). The largest CTA perforator or largest actual perforator was used 78% of the time. Increasing body mass index was not associated with larger CTA perforator size (P = 0.67) or more intense ICGLA blushes (P = 0.13). No significant correlation was found between CTA perforator location and ICGLA skin blush location, size, or intensity. CTA or SPY guided intraoperative procedure adjustments in 72% of patients. ICGLA identified poor soft-tissue perfusion and guided flap resection in 46% of patients. ICGLA skin blush location, size, and intensity do not correlate with CTA-identified perforating vessel location or actual perforating vessel size. Despite this, the ICGLA information was useful for evaluation of soft-tissue perfusion and flap design.

  4. [Comparative assessment of ct-bypass angiography and invasive coronary angiography in patients after coronary bypass surgery in the late postoperative period].

    Science.gov (United States)

    Men'kov, I A; Trufanov, G E; Zhelezniak, I S; Rud', S D; Kniazev, E A

    2013-10-01

    The aim of the study was to evaluate the diagnostic accuracy of ct-bypass angiography in the evaluation of significant stenosis and occlusion of grafts, recipient and nongrafted vessels in patients after coronary bypass surgery in the late postoperative period. Ct-bypass angiography was performed on 64-slice ct scanner with a slice thickness of 0.5 mm and a gantry rotation time of 0.4 s. All results were compared with quantitative invasive coronary angiography. 43 patients with 113 grafts were included in the study. Sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy for the evaluation of significant stenosis were 94%, 95%, 88%, 98%, 95%, respectively. Diagnostic accuracy for the evaluation of significant stenosis in the recipient and nongrafted vessels were 91% and 90%, respectively. The diagnostic accuracy for the evaluation graft occlusion, recipient and nongrafted vessels was 100%, 100% and 98%, respectively. Ct-bypass angiography allows accurate non-invasive assessment of significant stenosis and occlusion of coronary bypass grafts and native coronary arteries in patients after coronary bypass surgery in the late postoperative period.

  5. Determining the organ of origin of large pelvic masses in females using multidetector CT angiography and three-dimensional volume rendering CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Li, YangKang; Chen, JunWei; Chen, XueYin; Lin, JianBang; Cai, AiQun; Zhou, XiuGuo [Cancer Hospital, Shantou University Medical College, Department of Radiology, Shantou, Guangdong Province (China); Zheng, Yu [Cancer Hospital, Shantou University Medical College, Department of Clinical Pharmacology, Shantou (China)

    2015-04-01

    To study the value of tumour feeding arteries and the ovarian vein in determining the organ of origin of large pelvic tumours in females using multidetector CT. One hundred and thirty patients with 131 pathologically proven tumours (>6.5 cm) were retrospectively reviewed. Conventional CT images and CT angiography were evaluated, with focus on assessing the value of tumour feeding arteries and the ovarian vein in differentiating ovarian from non-ovarian tumours. For 97 ovarian tumours, the feeding arteries included the ovarian artery (n = 51) and the ovarian branch of uterine artery (n = 64). For 34 non-ovarian tumours, the feeding arteries included the ovarian artery (n = 2), the uterine artery (n = 21), the mesenteric artery (n = 5), and the internal iliac artery (n = 1). The ovarian vein was identified in 86 ovarian tumours and 12 non-ovarian tumours. When the feeding arteries and the ovarian vein were combined to confirm ovarian origin, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 97.8 %, 84.2 %, 93.8 %, 94.1 %, and 93.9 %, respectively. The accuracy was significantly higher than that of independently using the ovarian vein or the ovarian feeding arteries. Combined application of tumour feeding arteries and the ovarian vein is valuable to differentiate large ovarian from non-ovarian tumours. (orig.)

  6. Multislice CT angiography in aortic stent grafting: Relationship between image noise and body mass index

    Energy Technology Data Exchange (ETDEWEB)

    Sun Zhonghua [Discipline of Medical Imaging, Department of Imaging and Applied Physics, Curtin University of Technology, GPO Box U1987, Perth, Western Australia 6845 (Australia)]. E-mail: z.sun@curtin.edu.au

    2007-03-15

    Purpose: To investigate the correlation between image noise and body mass index (BMI) in multislice CT angiography (MSCT) for patients with abdominal aortic aneurysm (AAA) treated with endovascular stent grafts. Materials and methods: Seventeen patients who underwent MSCT following endovascular repair of AAA were included in the study. Image noise (standard deviation of the CT attenuation: S.D.) and signal to noise ratio (SNR) were plotted against BMI to demonstrate the correlation using a linear regression method. Image quality of 3D reconstructions was correlated to the SNR and BMI. Results: The r-value of linear regression between S.D. and BMI was 0.578 (p < 0.05), 0.835 and 0.802 (p < 0.001), respectively, at the level of renal artery, aortic aneurysm and common iliac artery. The r-value of linear regression between SNR and BMI was 0.332, 0.516 and 0.552 (p < 0.05), respectively, at above three levels. Image quality of 3D reconstructions was compromised in five patients and diagnosis was affected in two patients with BMI more than 30. Conclusion: A significant correlation was observed between image noise and BMI in MSCT angiography of endovascular repair of AAA. Our findings are valuable for optimisation of MSCT angiography scanning protocols and reduction of radiation dose in MSCT examinations.

  7. Pre-test probability of obstructive coronary stenosis in patients undergoing coronary CT angiography: Comparative performance of the modified diamond-Forrester algorithm versus methods incorporating cardiovascular risk factors.

    Science.gov (United States)

    Ferreira, António Miguel; Marques, Hugo; Tralhão, António; Santos, Miguel Borges; Santos, Ana Rita; Cardoso, Gonçalo; Dores, Hélder; Carvalho, Maria Salomé; Madeira, Sérgio; Machado, Francisco Pereira; Cardim, Nuno; de Araújo Gonçalves, Pedro

    2016-11-01

    Current guidelines recommend the use of the Modified Diamond-Forrester (MDF) method to assess the pre-test likelihood of obstructive coronary artery disease (CAD). We aimed to compare the performance of the MDF method with two contemporary algorithms derived from multicenter trials that additionally incorporate cardiovascular risk factors: the calculator-based 'CAD Consortium 2' method, and the integer-based CONFIRM score. We assessed 1069 consecutive patients without known CAD undergoing coronary CT angiography (CCTA) for stable chest pain. Obstructive CAD was defined as the presence of coronary stenosis ≥50% on 64-slice dual-source CT. The three methods were assessed for calibration, discrimination, net reclassification, and changes in proposed downstream testing based upon calculated pre-test likelihoods. The observed prevalence of obstructive CAD was 13.8% (n=147). Overestimations of the likelihood of obstructive CAD were 140.1%, 9.8%, and 18.8%, respectively, for the MDF, CAD Consortium 2 and CONFIRM methods. The CAD Consortium 2 showed greater discriminative power than the MDF method, with a C-statistic of 0.73 vs. 0.70 (pMDF method. Adoption of these scores may improve disease prediction and change the diagnostic pathway in a significant proportion of patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Arterial enhancement at abdominal CT angiography: Low- versus high-osmolality contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Rouviere, O.; Berger, P.; Pangaud, C.; Lyonnet, D. [Hopital E. Herriot, Lyon (France). Dept. of Vascular and Genitourinary Radiology; Ecochard, R. [Hospices Civils de Lyon (France). Dept of Biostatistics; Fontaine, B. [Laboratoire Guerbet, Roissy (France)

    2000-09-01

    Purpose: To evaluate the effects of contrast media pharmokinetic differences on aortic enhancement at abdominal CT angiography and to determine whether these effects are of clinical relevance. Material and Methods: Two hundred and twelve patients referred for abdominal CT angiography were included in the study. All abdominal CT angiograms were performed with the same parameters (collimation 3 mm, pitch ratio 1.7, scan delay 30 s) after i.v. injection of 120 ml of contrast medium at 3 ml/s. After randomization, patients received either iobitridol 300 (low-osmolar, 300 mg I/ml), iobitridol 350 (low-osmolar, 350 mg I/ml) or ioxithalamate 350 (high-osmolar, 350 mg I/ml). The time attenuation curves obtained with the three contrast media were compared. Results: The time attenuation curve obtained with ioxithalamate 350 was not parallel to those obtained with iobitridol 300 and iobitridol 350. Mean peak enhancements obtained with iobitridol 350 and ioxithalamate 350 were not significantly different but iobitridol 350 provided higher mean peak enhancement than iobitridol 300. Mean delays of the peak enhancements were the same with the three contrast media. After peak enhancement, the decrease of aortic opacification under a selected threshold of 200 HU was significantly slower with iobitridol 350 than with iobitridol 300 and ioxithalamate 350, whereas iobitridol 300 and ioxithalamate 350 showed no significant differences. Conclusion: For a given iodine concentration, low-osmolality contrast media provide longer aortic opacification and may be recommended for CT angiography when long acquisition times are needed.

  9. Data of evolutionary structure change: 1CCTA-1ZNCA [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available Chain>A 1CCTA VHWNT--KYGDF ure...Chain>A 1CCTA FLKVG-SAKPG ure>... A 1CCTA LKFRK-LNFNG ...1CCTA-1ZNCA 1CCT 1ZNC A A WGY--GKHNG------PEHWHKDFPIAKGERQSPVDIDT...ex>0 1CCT A 1CCTA

  10. CT-angiography source images indicate less fatal outcome despite coma of patients in the Basilar Artery International Cooperation Study

    NARCIS (Netherlands)

    Pallesen, Lars P.; Khomenko, Andrei; Dzialowski, Imanuel; Barlinn, Jessica; Barlinn, Kristian; Zerna, Charlotte; van der Hoeven, Erik J R J; Algra, Ale; Kapelle, L. Jaap; Michel, Patrik; Bodechtel, Ulf; Demchuk, Andrew M.; Schonewille, Wouter; Puetz, Volker

    2017-01-01

    Background: Coma is associated with poor outcome in patients with basilar artery occlusion. Aims: We sought to assess whether the posterior circulation Acute Stroke Prognosis Early CT Score and the Pons-Midbrain Index applied to CT angiography source images predict the outcome of comatose patients

  11. Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

    Energy Technology Data Exchange (ETDEWEB)

    Cai Weixing; Zhao Binghui; Conover, David; Liu Jiangkun; Ning Ruola [Department of Imaging Sciences, University of Rochester, 601 Elmwood Avenue, Rochester, New York 14642 (United States); Department of Radiology, Shanghai 6th People' s Hospital, 600 Yishan Road, Xuhui, Shanghai (China); Koning Corporation, Lennox Tech Enterprise Center, 150 Lucius Gordon Drive Suite 112, West Henrietta, New York 14586 (United States); Department of Imaging Sciences, University of Rochester, 601 Elmwood Avenue, Rochester, New York 14642 (United States); Department of Imaging Sciences, University of Rochester, 601 Elmwood Avenue, Rochester, New York 14642 (United States) and Koning Corporation, Lennox Tech Enterprise Center, 150 Lucius Gordon Drive Suite 112, West Henrietta, New York 14586 (United States)

    2012-01-15

    Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

  12. Pitfalls in post-mortem CT-angiography--intravascular contrast induces post-mortem pericardial effusion.

    Science.gov (United States)

    Berger, Nicole; Martinez, Rosita; Winklhofer, Sebastian; Flach, Patricia M; Ross, Steffen; Ampanozi, Garyfalia; Gascho, Dominic; Thali, Michael J; Ruder, Thomas D

    2013-11-01

    We present a case where multi-phase post-mortem computed tomography angiography (PMCTA) induced a hemorrhagic pericardial effusion during the venous phase of angiography. Post-mortem non-contrast CT (PMCT) suggested the presence of a ruptured aortic dissection. This diagnosis was confirmed by PMCTA after pressure controlled arterial injection of contrast. During the second phase of multi-phase PMCTA the presence of contrast leakage from the inferior cava vein into the pericardial sac was noted. Autopsy confirmed the post-mortem nature of this vascular tear. This case teaches us an important lesson: it underlines the necessity to critically analyze PMCT and PMCTA images in order to distinguish between artifacts, true pathologies and iatrogenic findings. In cases with ambiguous findings such as the case reported here, correlation of imaging findings with autopsy is elementary.

  13. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  14. Diagnostic accuracy of dual energy CT angiography in patients with diabetes mellitus; Diagnostische Genauigkeit der Dual-energy-CT-Angiographie bei Patienten mit Diabetes mellitus

    Energy Technology Data Exchange (ETDEWEB)

    Schabel, C.; Bongers, M.N.; Syha, R. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Klinikum der Eberhard-Karls-Universitaet, Sektion fuer Experimentelle Radiologie der Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Ketelsen, D.; Homann, G.; Notohamiprodjo, M.; Nikolaou, K.; Bamberg, F. [Klinikum der Eberhard-Karls-Universitaet, Abteilung fuer Diagnostische und Interventionelle Radiologie, Tuebingen (Germany); Thomas, C. [Universitaetsklinikum Duesseldorf, Abteilung fuer Diagnostische und Interventionelle Radiologie, Duesseldorf (Germany)

    2015-04-01

    Peripheral arterial disease (PAD) represents a major and highly prevalent complication in patients with diabetes mellitus. The diagnostic, non-invasive work-up by computed tomography angiography (CTA) is limited in the presence of extensive calcification. The aim of the study was to determine the diagnostic accuracy of dual energy CTA (DE-CTA) for the detection and characterization of PAD in patients with diabetes mellitus. In this study 30 diabetic patients with suspected or known PAD were retrospectively included in the analysis. All subjects underwent DE-CTA (Somatom Definition Flash, Siemens Healthcare, Erlangen, Germany) prior to invasive angiography, which served as the reference standard. Blinded analysis included assessment of the presence and degree of peripheral stenosis on curved multiplanar reformatting (MPR) and maximum intensity projections (MIP). Conventional measures of diagnostic accuracy were derived. Among the 30 subjects included in the analysis (83 % male, mean age 70.0 ± 10.5 years, 83 % diabetes type 2), the prevalence of critical stenosis in 331 evaluated vessel segments was high (30 %). Dual energy CT identified critical stenoses with a high sensitivity and good specificity using curved MPR (100 % and 93.1 %, respectively) and MIP images (99 % and 91.8 %, respectively). In stratified analysis, the diagnostic accuracy was higher for stenosis pertaining to the pelvic and thigh vessels as compared with the lower extremities (curved MPR accuracy 97.1 % vs. 99.2 vs. 90.9 %; respectively, p < 0.001). The use of DE-CTA allows reliable detection and characterization of peripheral arterial stenosis in patients with diabetes mellitus with higher accuracy in vessels in the pelvic and thigh regions compared with the vessels in the lower legs. (orig.) [German] Die periphere arterielle Verschlusskrankheit (PAVK) ist eine wesentliche Komplikation des Diabetes mellitus und stellt aufgrund ausgepraegter Gefaessverkalkungen eine diagnostische

  15. High-pitch coronary CT angiography with third generation dual-source CT: limits of heart rate.

    Science.gov (United States)

    Gordic, Sonja; Husarik, Daniela B; Desbiolles, Lotus; Leschka, Sebastian; Frauenfelder, Thomas; Alkadhi, Hatem

    2014-08-01

    To determine the average heart rate (HR) and heart rate variability (HRV) required for diagnostic imaging of the coronary arteries in patients undergoing high-pitch CT-angiography (CTA) with third-generation dual-source CT. Fifty consecutive patients underwent CTA of the thoracic (n = 8) and thoracoabdominal (n = 42) aorta with third-generation dual-source 192-slice CT with prospective electrocardiography (ECG)-gating at a pitch of 3.2. No β-blockers were administered. Motion artifacts of coronary arteries were graded on a 4-point scale. Average HR and HRV were noted. The average HR was 66 ± 11 beats per minute (bpm) (range 45-96 bpm); the HRV was 7.3 ± 4.4 bpm (range 3-20 bpm). Interobserver agreement on grade of image quality for the 642 coronary segments evaluated by both observers was good (κ = 0.71). Diagnostic image quality was found for 608 of the 642 segments (95%) in 43 of 50 patients (86%). In 14% of the patients, image quality was nondiagnostic for at least one segment. HR (p = 0.001) was significantly higher in patients with at least one non-diagnostic segment compared to those without. There was no significant difference (p > 0.05) in HRV between patients with nondiagnostic segments and those with diagnostic images of all segments. All patients with a HR CT allows for coronary angiography in the prospectively ECG-gated high-pitch mode with diagnostic image quality at HR up to 70 bpm. HRV is not significantly related to image quality of coronary CTA.

  16. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hyeon Hoe [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors.

  17. Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique

    Energy Technology Data Exchange (ETDEWEB)

    Klass, Oliver; Jeltsch, Martin; Feuerlein, Sebastian; Brunner, Horst; Brambs, Hans-Juergen; Hoffmann, Martin H.K. [University Hospital of Ulm, Department of Diagnostic and Interventional Radiology, Ulm (Germany); Nagel, Hans-Dieter [Philips Healthcare, Department of Science and Technology, Hamburg (Germany); Walker, Matthew J. [CT Clinical Science, Philips Healthcare, Cleveland, OH (United States)

    2009-04-15

    To assess image quality and radiation exposure with prospectively gated axial CT coronary angiography (PGA) compared to retrospectively gated helical techniques (RGH). Forty patients with suspected coronary artery disease (CAD) and a stable heart rate below 65 bpm underwent CT coronary angiography (CTCA) using a 64-channel CT system. The patient cohort consisted of 20 consecutive patients examined using a PGA technique and 20 patients examined using a standard RGH technique. Both groups were matched demographically according to age, gender, body mass index, and heart rate. For both groups, two independent observers assessed image quality for all coronary segments on an ordinal scale from 1 (nonassessable) to 5 (excellent quality). Image quality and radiation exposure were compared between patient groups. There were no significant differences in vessel-based image quality between the two groups (P > 0.05). Mean ({+-} SD) effective radiation exposure in the PGA group was 3.7 {+-} 0.8 mSv compared to 18.9 {+-} 3.8 mSv in the RGH group without ECG-based tube current modulation (P < 0.001). Preliminary experience shows PGA technique to be a promising approach for CTCA resulting in a substantial reduction in radiation exposure with image quality comparable to that of standard RGH technique. (orig.)

  18. Diagnostic performance of 320-detector CT coronary angiography in patients with atrial fibrillation: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Lei; Yang, Lin; Fan, Zhanming; Yu, Wei; Lv, Biao; Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing Anzhen Hospital, Beijing (China)

    2011-05-15

    To evaluate the feasibility, diagnostic accuracy, and radiation dose of CT coronary angiography (CTCA) in patients with atrial fibrillation (AF) using 320-detector CT. Thirty-seven patients with persistent AF and suspected coronary artery disease (CAD) were enrolled. All patients underwent both 320-detector CTCA and conventional coronary angiography (CCA). CT image quality and the presence of significant ({>=}50%) stenosis were evaluated by two radiologists blinded to the results of CCA. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated using CCA as the reference standard. Differences in detection of coronary artery stenosis between 320-detector CTCA and CCA were evaluated with McNemar's test. Patient radiation dose was calculated by multiplying dose length product by conversion coefficient of 0.017. In total 474 evaluated coronary segments, 459 (96.8%) segments were diagnostically evaluable. On per-segment analysis, sensitivity, specificity, PPV and NPV were 90.0% (18 of 20), 99.3% (436 of 439), 85.7% (18 of 21) and 99.5% (436 of 438). No significant difference was found between 320-detector CTCA and CCA on the detection of significant stenosis (P = 1.000). Effective doses of 320-detector CTCA was 13.0 {+-} 4.7 mSv. 320-detector CTCA is feasible and accurate in excluding CAD in patients with AF. (orig.)

  19. Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why.

    Science.gov (United States)

    Fishman, Elliot K; Ney, Derek R; Heath, David G; Corl, Frank M; Horton, Karen M; Johnson, Pamela T

    2006-01-01

    The introduction and widespread availability of 16-section multi-detector row computed tomographic (CT) technology and, more recently, 64-section scanners, has greatly advanced the role of CT angiography in clinical practice. CT angiography has become a key component of state-of-the-art imaging, with applications ranging from oncology (eg, staging of pancreatic or renal cancer) to classic vascular imaging (eg, evaluation of aortic aneurysms and renal artery stenoses) as well as newer techniques such as coronary artery imaging and peripheral runoff studies. With an average of 400-1000 images in each volume data set, three-dimensional postprocessing is crucial to volume visualization. Radiologists now have workstations that provide capabilities for evaluation of these data sets by using a range of software programs and processing tools. Although different systems have unique capabilities and functionality, all provide the options of volume rendering and maximum intensity projection for image display and analysis. These two postprocessing techniques have different advantages and disadvantages when used in clinical practice, and it is important that radiologists understand when and how each technique should be used. Copyright RSNA, 2006.

  20. Bolus timing in high-pitch CT angiography of the aorta

    Energy Technology Data Exchange (ETDEWEB)

    Beeres, Martin, E-mail: beeres@gmx.net [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Loch, Matthias, E-mail: MatthiasLoch@gmx.net [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Schulz, Boris, E-mail: boris.schell@googlemail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Kerl, Matthias, E-mail: matthias.kerl@gmail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Al-Butmeh, Firas, E-mail: Firas.Albutmeh@gmail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Bodelle, Boris, E-mail: bbodelle@googlemail.com [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Herrmann, Eva, E-mail: Herrmann@Med.Uni-Frankfurt.de [Clinic of the Goethe University, Department of Biostatistics, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Gruber-Rouh, Tatjana, E-mail: tatjanagruber2004@yahoo.de [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Lee, Clara, E-mail: Clara.Lee@kgu.de [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Jacobi, Volkmar, E-mail: Volkmar.Jacobi@kgu.de [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); Vogl, Thomas J., E-mail: T.Vogl@em.uni-frankfurt.de [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt (Germany); and others

    2013-06-15

    Objective: To investigate the bolus geometry in high-pitch CT angiography (CTA) of the aorta without ECG synchronisation in comparison to single-source CT. Methods: Overall 160 consecutive patients underwent CTA either in conventional single-source mode with a pitch of 1.2 (group 1), or in dual-source mode with a pitch of 3.0 (groups 2, 3 and 4) using different contrast media timings with bolus triggering at 140 HU (5 s, group 1; 10 s, group 2; 12 s, group 3; 14 s, group 4). Contrast material, saline flush, flow rate and kV/mAs settings were kept equal for optimum comparability. Aortic attenuation was measured along the z-axis of the patient at different anatomic landmarks and subjective image quality was compared. Results: The most homogeneous enhancement of the aorta was reached with a delay of 10 s after reaching the trigger threshold. The imaging length was not significantly different, but the examination time was significantly (p < 0.001) shorter in the high-pitch group (7.7 s vs. 1.7 s for group 1 vs. 2, 3 and 4). Conclusion: In high-pitch CT angiography using a start delay of 10 s after a trigger threshold of 140 HU in the descending aorta is reached, a homogenous contrast along the z-axis is accomplished.

  1. The frequency of intracranial arterial fenestrations: A study with 64-detector CT-angiography

    Energy Technology Data Exchange (ETDEWEB)

    Bayrak, Aylin Hasanefendioglu, E-mail: aylin_has@yahoo.com [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Senturk, Senem, E-mail: ssenturk@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Akay, Hatice Ozturkmen, E-mail: hozturkmen@gmail.com [Veni Vidi Hospital, Diyarbakir (Turkey); Ozmen, Cihan Akgul, E-mail: cihanakgul@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Bukte, Yasar, E-mail: ybukte@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey); Nazaroglu, Hasan, E-mail: hnazarog@dicle.edu.tr [Dicle University, School of Medicine, Radiology Department, Diyarbakir (Turkey)

    2011-03-15

    Fenestration is a vascular variation that begins with a common origin, then splits into two parallel luminal channels and rejoins distally. Potential association between anomalies of cerebral circulation and increased occurrence of aneurysm makes intracranial arterial fenestrations important. The planning of intracranial arterial interventions may be complicated if a fenestration occurs proximal to the site of intended treatment. This study is planned to determine the frequency of fenestrations on CT angiography and to search whether there is relationship between aneurysms and fenestrations. CT angiographies of 395 consecutive patients, performed by 64-detector CT, were retrospectively reviewed for aneurysms and fenestrations. Overall fenestration frequency, fenestration frequency in patients with and without aneurysm, and aneurysm frequency in patients with and without fenestration were searched. Demographic characteristics of patients were also compared. Overall fenestration frequency was 12.9%. Vertebrobasilar system (5.56%) and anterior communicating region (5.32%) were the two most frequent sites of fenestration. The rate of fenestrations was not significantly different between patients who had and did not have aneurysms. Mean age was significantly higher, and females were predominant in patients with aneurysms. However our results did not show significant difference in age and sex of patients with fenestrations. The frequency of fenestrations in this study is higher than in previously published radiological studies, suggesting that fenestrations are relatively common. There is no significant relationship between the frequency of aneurysms and fenestrations.

  2. Digital subtraction angiography in the diagnosis of invasive hydatidiform mole. Comparison with PAG, CT and USG

    Energy Technology Data Exchange (ETDEWEB)

    Ikuma, Kenichiro; Daimon, Michiko; Muranaka, Junko; Suno, Shigeo; Takayasu, Yukio; Shibahara, Hiroaki; Sawai, Hideaki

    1987-11-01

    Pelvic angiography (PAG) by Seldinger is one of the most useful examinations for the diagnosis of trophoblastic disease and also for the assessment of the therapeutic results. This technique, however, causes some stress to the patient. Therefore, noninvasive method, such as computed tomography (CT) and ultrasonography (USG) have recently been introduced. In the 1980s, digital subtraction angiography (DSA) was developed. It is now being used increasingly in the fields of Obstetrics and Gynecology as a substitute for the conventional PAG. In this report, the results of DSA, PAG, CT and USG which were carried out before and after chemotherapy in a patient with invasive hydatidiform mole were compared. In terms of the location, size and shape of the lesion, the CT findings were almost the same as those of USG. In terms of the angiographic findings in the affected area, intravenous DSA (IVDSA) was a sufficiently substitutional examination for conventional PAG. With IVDSA, arterial images can be obtained following the intravenous injection of a contrast medium. Therefore, this technique is excellent in terms of simplicity and safety. From now on, DSA will be utilized instead of PAG as an effective diagnostic method for trophoblastic disease and for follow-up such cases.

  3. Cone-beam CT angiography of the thorax. An experimental study

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Katsuya; Shimada, Kazuhiro [Chiba Univ. (Japan). School of Medicine; Tadokoro, Hiroyuki (and others)

    1999-10-01

    The authors recently developed a cone-beam computed tomography (CT) scanner and this report presents their evaluation of its potential for thoracic vascular imaging. An X-ray tube and a video-fluoroscopic system were rotated around the objects and 360 projected images were collected in a 12-s scan. Each image was digitized and a 3 dimensional (D) image (256 x 256 x 256 voxel volume with a voxel dimension of 0.9 x 0.9 x 0.9 mm) was reconstructed. Two different 3D-CT angiographies were investigated in 2 pigs: right atriography and thoracic aortography. Each pig was anesthetized, mechanically ventilated and positioned within the scanner. Contrast agent was infused through the right atrium or the aortic root at a rate of 3 ml/s during the scan. The right atriography scan clearly delineated the anatomy of the pulmonary artery, heart chambers and thoracic aorta. The thoracic aortography scan also clearly delineated the aortic anatomy including the internal thoracic and intercostal arteries. In conclusion, cone-beam CT angiography is potentially useful for thoracic vascular imaging. (author)

  4. Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT

    Energy Technology Data Exchange (ETDEWEB)

    Hein, Patrick A.; May, Juliane; Rogalla, Patrik; Hamm, Bernd; Lembcke, Alexander [Charite-University Hospital, Department of Radiology, Berlin (Germany); Butler, Craig [Charite-University Hospital, Department of Radiology, Berlin (Germany); University of Alberta, Department of Cardiology, Edmonton, Alberta (Canada)

    2010-06-15

    To assess reduced volumes of contrast agent on image quality for coronary computed tomography angiography (CCTA) by using single-beat cardiac imaging with 320-slice CT. Forty consecutive male patients (mean age: 55.8 years) undergoing CCTA with body weight {<=}85 kg, heart rate {<=}65 bpm, and ejection fraction {>=}55% were included. Image acquisition protocol was standardized (120 kV, 400 mA, and prospective ECG-triggered single-beat nonspiral CCTA). Patients were randomly assigned to one of four groups (G1: received 40 ml, G2: 50 ml, G3: 60 ml, G4: 70 ml). Groups were compared with respect to aortic attenuation, image noise, and image quality. CT values (mean {+-} standard deviation) in the aortic root were measured as 423 {+-} 38 HU in G1, and 471 {+-} 68, 463 {+-} 60, and 476 {+-} 78 HU in G2-4, respectively. There were no statistically significant differences in attenuation among the groups (P > 0.068). All 40 CT datasets were rated diagnostic, and image noise and image quality were not statistically different among groups. Using 320-slice volume CT, diagnostic image quality can be achieved with 40 ml of contrast material in CCTA in patients with normal body weight, cardiac function, and low heart rate. (orig.)

  5. Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Leschka, Sebastian; Husmann, Lars; Desbiolles, Lotus M.; Boehm, Thomas; Marincek, Borut; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Gaemperli, Oliver; Schepis, Tiziano; Koepfli, Pascal [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Center for Integrative Human Physiology, Zurich (Switzerland)

    2006-09-15

    The reconstruction intervals providing best image quality for non-invasive coronary angiography with 64-slice computed tomography (CT) were evaluated. Contrast-enhanced, retrospectively electrocardiography (ECG)-gated 64-slice CT coronary angiography was performed in 80 patients (47 male, 33 female; mean age 62.1{+-}10.6 years). Thirteen data sets were reconstructed in 5% increments from 20 to 80% of the R-R interval. Depending on the average heart rate during scanning, patients were grouped as <65 bpm (n=49) and {>=}65 bpm (n=31). Two blinded and independent readers assessed the image quality of each coronary segment with a diameter {>=}1.5 mm using the following scores: 1, no motion artifacts; 2, minor artifacts; 3, moderate artifacts; 4, severe artifacts; and 5, not evaluative. The average heart rate was 63.3{+-}13.1 bpm (range 38-102). Acceptable image quality (scores 1-3) was achieved in 99.1% of all coronary segments (1,162/1,172; mean image quality score 1.55{+-}0.77) in the best reconstruction interval. Best image quality was found at 60% and 65% of the R-R interval for all patients and for each heart rate subgroup, whereas motion artifacts occurred significantly more often (P<0.01) at other reconstruction intervals. At heart rates <65 bpm, acceptable image quality was found in all coronary segments at 60%. At heart rates {>=}65 bpm, the whole coronary artery tree could be visualized with acceptable image quality in 87% (27/31) of the patients at 60%, while ten segments in four patients were rated as non-diagnostic (scores 4-5) at any reconstruction interval. In conclusion, 64-slice CT coronary angiography provides best overall image quality in mid-diastole. At heart rates <65 bpm, diagnostic image quality of all coronary segments can be obtained at a single reconstruction interval of 60%. (orig.)

  6. Coronary computed tomography and triple rule out CT in patients with acute chest pain and an intermediate cardiac risk for acute coronary syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Henzler, Thomas, E-mail: thomas.henzler@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Gruettner, Joachim, E-mail: joachim.gruettner@umm.de [Emergency Department, University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); Meyer, Mathias, E-mail: mr.meyer.mathias@gmail.com [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Rothhaar, Baerbel, E-mail: baerbel.rothhaar@umm.de [Business Development – Medical Controlling, University Medical Center, Mannheim (Germany); Apfaltrer, Paul, E-mail: Paul.Apfaltrer@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Metzger, Franz, E-mail: franz.metzger@umm.de [Business Development – Medical Controlling, University Medical Center, Mannheim (Germany); Borggrefe, Martin, E-mail: martin.borggrefe@umm.de [1st Department of Medicine (Cardiology), University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoenberg, Stefan O., E-mail: stefan.schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center, Medical Faculty Mannheim, Heidelberg University, Mannheim (Germany); and others

    2013-01-15

    Objective: To evaluate the economic impact of integrating coronary CT angiography (cCTA) or whole chest “triple-rule-out” CTA (TRO-CTA) in the work-up of patients with acute chest pain. Materials and methods: 100 consecutive emergency department patients with acute chest pain and an intermediate cardiac risk for ACS underwent cCTA or TRO-CTA (cCTA group). Diagnostic performance, rate and length of hospitalization, hospital costs, hospital reimbursement and hospital profit were analyzed. All findings were compared to those of 100 different patients with acute chest pain that were evaluated with a standard of care (SOC) diagnostic algorithm (SOC group) that did not include cCTA. Diagnostic performance (“safety”) of both algorithms was defined as the absence of major adverse cardiac events (MACE) over a 90-day follow-up period. Results: In the cCTA group 60/100 patients were safely discharged at the same day. 19/100 patients were hospitalized due to significant coronary stenosis on cCTA, which was confirmed by invasive coronary catheterization (ICC) in 17/19 patients. Relevant non-coronary disease that led to hospitalization were found in 21 patients of the cCTA group. In the SOC group all patients were hospitalized. 87 of these hospitalized patients underwent ICC for exclusion of coronary artery stenosis. A significant coronary artery stenosis was found in only 25 of these patients. Within the cCTA group no patient suffered from MACE over the 90-day follow-up period. In the SOC group 2 patients were rehospitalized during the 90-day follow-up period due to recurrent chest pain and 1 patient because of a pseudoaneurym of the left femoral artery after ICC. The median hospital costs per patient were significantly lower in the cCTA group than in the SOC group (428.9€ vs. 1575.0€, p < 0.001). The median reimbursement of the cCTA group was less compared to the SOC group (589.8€ vs. 2412.1€, p < 0.001) and patients in the cCTA group gained less profit than

  7. Downstream resource utilization following hybrid cardiac imaging with an integrated cadmium-zinc-telluride/64-slice CT device

    Energy Technology Data Exchange (ETDEWEB)

    Fiechter, Michael; Kaufmann, Philipp A. [University Hospital Zurich, Department of Radiology, Cardiac Imaging, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology (ZIHP), Zurich (Switzerland); Ghadri, Jelena R.; Wolfrum, Mathias; Kuest, Silke M.; Pazhenkottil, Aju P.; Nkoulou, Rene N.; Herzog, Bernhard A.; Gebhard, Catherine; Fuchs, Tobias A.; Gaemperli, Oliver [University Hospital Zurich, Department of Radiology, Cardiac Imaging, Zurich (Switzerland)

    2012-03-15

    Low yield of invasive coronary angiography and unnecessary coronary interventions have been identified as key cost drivers in cardiology for evaluation of coronary artery disease (CAD). This has fuelled the search for noninvasive techniques providing comprehensive functional and anatomical information on coronary lesions. We have evaluated the impact of implementation of a novel hybrid cadmium-zinc-telluride (CZT)/64-slice CT camera into the daily clinical routine on downstream resource utilization. Sixty-two patients with known or suspected CAD were referred for same-day single-session hybrid evaluation with CZT myocardial perfusion imaging (MPI) and coronary CT angiography (CCTA). Hybrid MPI/CCTA images from the integrated CZT/CT camera served for decision-making towards conservative versus invasive management. Based on the hybrid images patients were classified into those with and those without matched findings. Matched findings were defined as the combination of MPI defect with a stenosis by CCTA in the coronary artery subtending the respective territory. All patients with normal MPI and CCTA as well as those with isolated MPI or CCTA finding or combined but unmatched findings were categorized as ''no match''. All 23 patients with a matched finding underwent invasive coronary angiography and 21 (91%) were revascularized. Of the 39 patients with no match, 5 (13%, p < 0.001 vs matched) underwent catheterization and 3 (8%, p < 0.001 vs matched) were revascularized. Cardiac hybrid imaging in CAD evaluation has a profound impact on patient management and may contribute to optimal downstream resource utilization. (orig.)

  8. Dose reduction during CT coronary angiography; La reduction de dose en coroscanographie

    Energy Technology Data Exchange (ETDEWEB)

    Willoteaux, S.; Sibileau, E.; Caroff, J.; Nedelcu, C.; Thouveny, F. [Service de Radiologie, Hopital Larrey, CHU d' Angers, 49 - Angers (France); Abi Kalil, W.; Delepine, S. [Service de Cardiologie, Hopital Larrey, CHU d' Angers, 49 - Angers (France)

    2010-11-15

    Dose delivery during CT coronary angiography with retrospective ECG gating is high especially due to the important slice overlapping. Optimization of the acquisition parameters is necessary to reduce patient exposure. First, the height of the scan field should be limited to the heart. Both kV and mA should be adjusted based on patient morphology. ECG gated exposure modulation with mA reduction during systole, a technique most applicable for patients with slow and regular heart rate, can result in a dose reduction up to 50%. The use of prospective ECG gating can also reduce patient dose. This technique also requires patients with slow and regular heart rate. (authors)

  9. Comparison of Coronary CT Angiography, SPECT, PET, and Hybrid Imaging for Diagnosis of Ischemic Heart Disease Determined by Fractional Flow Reserve.

    Science.gov (United States)

    Danad, Ibrahim; Raijmakers, Pieter G; Driessen, Roel S; Leipsic, Jonathon; Raju, Rekha; Naoum, Chris; Knuuti, Juhani; Mäki, Maija; Underwood, Richard S; Min, James K; Elmore, Kimberly; Stuijfzand, Wynand J; van Royen, Niels; Tulevski, Igor I; Somsen, Aernout G; Huisman, Marc C; van Lingen, Arthur A; Heymans, Martijn W; van de Ven, Peter M; van Kuijk, Cornelis; Lammertsma, Adriaan A; van Rossum, Albert C; Knaapen, Paul

    2017-08-16

    At present, the choice of noninvasive testing for a diagnosis of significant coronary artery disease (CAD) is ambiguous, but nuclear myocardial perfusion imaging with single-photon emission tomography (SPECT) or positron emission tomography (PET) and coronary computed tomography angiography (CCTA) is predominantly used for this purpose. However, to date, prospective head-to-head studies are lacking regarding the diagnostic accuracy of these imaging modalities. Furthermore, the combination of anatomical and functional assessments configuring a hybrid approach may yield improved accuracy. To establish the diagnostic accuracy of CCTA, SPECT, and PET and explore the incremental value of hybrid imaging compared with fractional flow reserve. A prospective clinical study involving 208 patients with suspected CAD who underwent CCTA, technetium 99m/tetrofosmin-labeled SPECT, and [15O]H2O PET with examination of all coronary arteries by fractional flow reserve was performed from January 23, 2012, to October 25, 2014. Scans were interpreted by core laboratories on an intention-to-diagnose basis. Hybrid images were generated in case of abnormal noninvasive anatomical or functional test results. Hemodynamically significant stenosis in at least 1 coronary artery as indicated by a fractional flow reserve of 0.80 or less and relative diagnostic accuracy of SPECT, PET, and CCTA in detecting hemodynamically significant CAD. Of the 208 patients in the study (76 women and 132 men; mean [SD] age, 58 [9] years), 92 (44.2%) had significant CAD (fractional flow reserve ≤0.80). Sensitivity was 90% (95% CI, 82%-95%) for CCTA, 57% (95% CI, 46%-67%) for SPECT, and 87% (95% CI, 78%-93%) for PET, whereas specificity was 60% (95% CI, 51%-69%) for CCTA, 94% (95% CI, 88%-98%) for SPECT, and 84% (95% CI, 75%-89%) for PET. Single-photon emission tomography was found to be noninferior to PET in terms of specificity (P  .99) using the predefined absolute margin of 10%. Diagnostic accuracy was

  10. Preoperative diagnosis of the thoracic aortic aneurysm by three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Hideo; Ino, Takashi; Ide, Hirofumi; Mizuhara, Akihiro; Yamaguchi, Atsushi; Kawahito, Koji; Kobayashi, Yasuyuki; Nagai, Jun (Jichi Medical School, Minamikawachi, Tochigi (Japan))

    1993-09-01

    Serial eight patients with thoracic aortic aneurysms were evaluated by a newly developed three-dimensional CT angiography (3D-CT) from December 1992 to January 1993. The patients include 3 aortic dissections, 3 aortic arch aneurysms, one descending aortic aneurysm and one thoraco-abdominal aortic aneurysm. The surgical treatment was performed after the evaluation of 3D-CT, and the operative findings were compared to the three-dimensional images reconstructed by 3D-CT in all patients. Three-dimensional displays were achieved using the unique method of data collection of the helical (spinal) scanner with continuous tube rotation and continuous table feed. An intravenous contrast material was used to image the thoracic aorta and major aortic branches with the single-breath-hold technique. Two and three-dimensional images reconstructed by 3D-CT were displayed within 10-20 minutes after the scanning. These three-dimensional images of the aortic lesions could be displayed in any angle we chose. Three-dimensional structures of the thoracic aorta and major aortic branches were clearly visualized and easily recognized by 3D-CT. These images were similar to the intraoperative findings and were quite useful to determine the operative procedure. The successful repair of thoracic aortic aneurysm was achieved in all cases. 3D-CT is a new and attractive modality to assess the vascular system. Although our experience is limited, 3D-CT may be a useful and powerful diagnostic method for the surgical treatment of thoracic aortic aneurysm. (author).

  11. Comparative Study on 16-slice CT Coronary Angiography vs Conventional Coronary Angiography-A Report of 38 Cases

    Institute of Scientific and Technical Information of China (English)

    Yan CHEN; Ping HAN; Bo LIANG; Huimin LIANG; Ziqiao LEI; Zhiliang TIAN; Gansheng FENG; Jie XIAO

    2008-01-01

    The clinical application of 16-slice CT coronary angiography (CTCA) and the impact of plaques differently characterized on assessing coronary artery stenosis were evaluated. Thirty-eight patients with coronary artery disease diagnosed by conventional coronary angiography (CAG) un- derwent 16-slice CTCA (collimation: 16×0.75 mm; rotation time: 420 msec; kernel: 35f; effective current: 500 mAs; tube voltage: 120 kV). The interval between CTCA and CAG was within one month. CTCA was evaluated by consensus of two independent experienced radiologists unknowing CAG findings. Original images, maximum intensity projections and multiplanar reconstructions were used to assess coronary artery stenosis. For a determined plaque an attenuation value≥130 HU was considered as calcified, and <130 HU noncalcified. The plaques were then classified into significant calcification (extensive calcification), medium calcification (small isolated calcification) and noncal- cification. The diagnostic accuracy of 16-slice CTCA findings as well as to detect ≥50% stenoses caused by plaques was evaluated respectively regarding CAG as the standard of reference. In com- parison with CAG findings, the sensitivity, specificity, positive and negative predictive value derived from CTCA for mild stenosis (<50%) were 72.7%, 38.5%, 50%, 62.5%, respectively; for moderate stenosis (50%-75%) 82.4%, 72.7%, 70%, 84.2%, resepctively; and for severe coronary stenosis (>75%) 85%, 90.5%, 81%, 92.7% respectively. With the increase of stenoses degree, the value of CTCA was greater. For the classification of the plaque calcification with ≥50% stenosis CTCA at- tained the sensitivity, specificity, positive and negative predictive value for severe calcificatoin 73.3%, 22.2%, 61.1% and 33.3%, respectively; for moderate calcification 70%, 55.6%, 63.6% and 62.5%, respectively; for noncalcification 93.8%, 85.7%, 93.8% and 85.7% respectively. CTCA was restricted in assessing coronary artery stenosis in the

  12. Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Jensen, Claus Verner

    2009-01-01

    The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have...... high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare...

  13. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    Science.gov (United States)

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  14. Diagnosis of the thoracic aortic aneurysm by three-dimensional CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Adachi, Hideo; Ino, Takafumi; Kobayashi, Yasuyuki; Nagai, Jun; Ide, Hirofumi; Mizuhara, Akihiro; Yamaguchi, Atsushi; Kawahito, Koji (Jichi Medical School, Minamikawachi, Tochigi (Japan))

    1993-07-01

    Twenty patients with thoracic aortic aneurysms were evaluated by a newly developed three-dimensional CT angiography (3D-CT) from December 1992 to February 1993. The patients included 12 aortic dissections, 7 true thoracic aortic aneurysms and one thoraco-abdominal aortic aneurysm. Three-dimensional displays were achieved rapidly in all cases using helical (spinal) CT which is a new technology with continuous tube rotation and continuous table feed. An intravenous contrast material was used to image the thoracic aortic aneurysm and the major aortic branches with single-breath-hold technique. Surgical treatment was performed in eight of 20 patients, and the aortic lesions in three cases were confirmed intraoperatively. Three-dimensional structures of the thoracic aorta and major branches were clearly visualized by 3D-CT and these images were useful to determine the operative procedure in surgical cases. 3D-CT is a new modality of evaluating the vascular system and may be a powerful and useful diagnostic method for the surgical intervention of thoracic aortic aneurysm. (author).

  15. CT coronary angiography: new risks for low-risk chest pain.

    Science.gov (United States)

    Radecki, Ryan Patrick

    2013-10-01

    Widespread conservative management of low-risk chest pain has motivated the development of a rapid triage strategy based on CT coronary angiography (CTCA) in the Emergency Department (ED). Recently, three prominent trials using this technology in the ED setting have presented results in support of its routine use. However, these studies fail to show the incremental prognostic value of CTCA over clinical and biomarker-based risk-stratification strategies, demonstrate additional downstream costs and interventions, and result in multiple harms associated with radio-contrast and radiation exposure. Observing the widespread overdiagnosis of pulmonary embolism following availability of CT pulmonary angiogram as a practice pattern parallel, CTCA use for low-risk chest pain in the ED should be advanced only with caution.

  16. From 3D to 4D: Integration of temporal information into CT angiography studies.

    Science.gov (United States)

    Haubenreisser, Holger; Bigdeli, Amir; Meyer, Mathias; Kremer, Thomas; Riester, Thomas; Kneser, Ulrich; Schoenberg, Stefan O; Henzler, Thomas

    2015-12-01

    CT angiography is the current clinical standard for the imaging many vascular illnesses. This is traditionally done with a single arterial contrast phase. However, advances in CT technology allow for a dynamic acquisition of the contrast bolus, thus adding temporal information to the examination. The aim of this article is to highlight the clinical possibilities of dynamic CTA using 2 examples. The accuracy of the detection and quantification of stenosis in patients with peripheral arterial occlusive disease, especially in stadium III and IV, is significantly improved when performing dynamic CTA examinations. The post-interventional follow-up of examinations of EVAR benefit from dynamic information, allowing for a higher sensitivity and specificity, as well as allowing more accurate classification of potential endoleaks. The described radiation dose for these dynamic examinations is low, but this can be further optimized by using lower tube voltages. There are a multitude of applications for dynamic CTA that need to be further explored in future studies.

  17. Anomalous origin of coronary artery: the role of multislice CT Angiography: a case report and literature review

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Daniel Rocha; Barros, Marcio Vinicius Lins; Nunes, Maria do Carmo Pereira; Siqueira, Maria Helena Albernaz, E-mail: marciovlbarros@uol.com.br [Hospital Mater Dei, Belo Horizonte, MG (Brazil)

    2012-07-15

    Anomalous origin of coronary arteries is a relatively rare entity and can present different clinical forms. Recently, CT angiography of the coronary arteries have demonstrated an important role in the diagnosis and management of these anomalies. We present the case of a young female without significant comorbidities who presented with cardiopulmonary arrest, being revived by a team of customer service mobile emergency. After completion of multislice CT angiography of the coronary arteries was observed anomalous origin of left main coronary artery in the right coronary artery, no signs of extrinsic compression. Patient received a defibrillator and had an uneventful follow-up performed. Multislice CT angiography is minimally invasive diagnostic methods to detect the origin and trajectory of the coronary arteries, allowing an alternative to cardiac catheterization for evaluation of patients with anomalous origin of coronary arteries. (author)

  18. Non-ECG-gated CT pulmonary angiography and the prediction of right ventricular dysfunction in patients suspected of pulmonary embolism

    DEFF Research Database (Denmark)

    Gutte, Henrik; Mortensen, Jann; Mørk, Mette Louise;

    2016-01-01

    PURPOSE: Right ventricular dysfunction (RVD) is an important prognostic factor of 30-day mortality in patients with acute pulmonary embolism (PE). The aim of our study was to evaluate whether non-electrocardiogram (ECG)-gated cardiovascular parameters attained during computed tomography pulmonary...... angiography (CTPA) could predict RVD in patients suspected of PE using ECG-gated cardiac CT angiography as reference. METHODS: Consecutive patients suspected of PE were referred to a ventilation/perfusion single-photon emission tomography (V/Q-SPECT) as first-line imaging procedure. Patients had a V....../Q-SPECT/CT, a CTPA and an ECG-gated cardiac CT angiography performed the same day. RESULTS: A total of 71 patients were available for analysis. Seventeen patients (24%) had RVD. The non-ECG-gated dimensions of left and right ventricle and the major vessels were correlated with ECG-gated cardiac dimensions. The size...

  19. Data of evolutionary structure change: 2Q1LB-3CCTA [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available A 3CCTA LETLIETHERGV ...2Q1LB-3CCTA 2Q1L 3CCT B A ------------------AKFLSDAEIIQLVNAKHIPAY...MTRGPVVRLPRACDSAEVKAWLETSEGFAVIKEAFDSTSRFARLQKLHTSIAGRNLYIRFQSRSGDAMGMNMISKGTEKALSKLHEYFPEMQILAVSGNYCTDKKPAA...INWIEGRGKSVVCEAVIPAKVVREVLKTTTEAMIEVNINKNLVGSAMAGSIGGYNAHAANIVTAIYIACGQDAAQNVGSSNCITLMEASGPTNEDLYISCT...AGRNLYIRFQSRSGDAMGMNMISKGTEKALSKLHEYFPEMQILAVSGNYCTDKKPAAINWIEGRGKSVVCEAVIPAKVVREVLKTTTEAMIEVNINKNLVGSAMAGSI

  20. Coronary CT angiography in clinical triage of patients at high risk of coronary artery disease

    DEFF Research Database (Denmark)

    Kühl, J Tobias; Hove, Jens D; Kristensen, Thomas S

    2017-01-01

    in patients with high likelihood of coronary artery disease and could, in theory, be used to triage high risk patients. As many obstacles remain, including logistical and safety issues, our study does not support the use of CCTA as an additional diagnostic test before ICA in an all-comer NSTEMI population.......%) coronary artery diameter stenosis with a sensitivity, specificity, and positive and negative predictive value of 99%, 81%, 96% and 95%, respectively. CCTA was used to triage patients into guideline defined treatment groups of "no or medical treatment", "referral to percutaneous coronary intervention...

  1. Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Tomizawa, Nobuo, E-mail: tomizawa-tky@umin.ac.jp [Department of Radiology, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Suzuki, Fumio; Akahane, Masaaki [Department of Radiology, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Torigoe, Rumiko [Toshiba Medical Systems Corporation, Tokyo Metropolitan Regional Office, 1-6, Tsukuda 2-Chome, Chuo-ku, Tokyo 104-0051 (Japan); Kiryu, Shigeru [Department of Radiology, Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo 108-8639 (Japan); Ohtomo, Kuni [Department of Radiology, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2013-08-15

    Objective: To investigate the effect of saline flush on coronary CT angiography of proximal, middle, and distal coronary artery segments, using 320-row CT, and to compare two injection duration protocols as to amount of contrast in the right heart chambers. Methods: This retrospective study was approved by the local ethics committee, and the requirement for informed consent to participate in this study was waived. The final study group included 108 patients who underwent coronary CT angiography. The first 36 patients received contrast medium without saline flush (group 1); the next 36 patients received contrast medium for 14 s and saline flush (group 2); the last 36 patients received contrast medium for 12 s and saline flush (group 3). The CT number, noise, contrast-to-noise ratio (CNR), and number of segments with a CT number greater than 325 Hounsfield units (HU) were recorded for proximal, middle, and distal segments. Results: The CT numbers and the CNR in groups 2 and 3 were significantly higher than that in group 1 (p < 0.005); the difference between groups 2 and 3 was not significant. The proportion of segments greater than 325 HU improved with saline flush (p < 0.05), with a larger improvement in the distal segments. Conclusions: Saline flush improves enhancement and CNR of coronary arteries, particularly of distal segments, in coronary CT angiography using 320-row CT. An average contrast medium injection of 44 mL was feasible using a saline flush.

  2. Dual-energy CT perfusion and angiography in chronic thromboembolic pulmonary hypertension: diagnostic accuracy and concordance with radionuclide scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Dournes, Gael; Verdier, Damien; Montaudon, Michel; Laurent, Francois; Lederlin, Mathieu [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France); University Bordeaux Segalen, Bordeaux Cedex (France); Bullier, Eric; Riviere, Annalisa [Hopital Haut-Leveque, CHU Bordeaux, Department of Nuclear Medicine, Pessac (France); Dromer, Claire [Hopital Haut-Leveque, CHU Bordeaux, Department of Respiratory Diseases, Pessac (France); Picard, Francois [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiology, Pessac (France); Billes, Marc-Alain [Hopital Haut-Leveque, CHU Bordeaux, Department of Cardiac Surgery, Pessac (France); Corneloup, Olivier [Hopital Haut-Leveque, CHU Bordeaux, Department of Medical Imaging, Pessac (France)

    2014-01-15

    To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) perfusion and angiography versus ventilation/perfusion (V/Q) scintigraphy in chronic thromboembolic pulmonary hypertension (CTEPH), and to assess the per-segment concordance rate of DECT and scintigraphy. Forty consecutive patients with proven pulmonary hypertension underwent V/Q scintigraphy and DECT perfusion and angiography. Each imaging technique was assessed for the location of segmental defects. Diagnosis of CTEPH was established when at least one segmental perfusion defect was detected by scintigraphy. Diagnostic accuracy of DECT perfusion and angiography was assessed and compared with scintigraphy. In CTEPH patients, the per-segment concordance between scintigraphy and DECT perfusion/angiography was calculated. Fourteen patients were diagnosed with CTEPH and 26 with other aetiologies. DECT perfusion and angiography correctly identified all CTEPH patients with sensitivity/specificity values of 1/0.92 and 1/0.93, respectively. At a segmental level, DECT perfusion showed moderate agreement (κ = 0.44) with scintigraphy. Agreement between CT angiography and scintigraphy ranged from fair (κ = 0.31) to slight (κ = 0.09) depending on whether completely or partially occlusive patterns were considered, respectively. Both DECT perfusion and angiography show satisfactory performance for the diagnosis of CTEPH. DECT perfusion is more accurate than angiography at identifying the segmental location of abnormalities. (orig.)

  3. The clinical application of multi-slice spiral CT angiography in abdominal aortic disease

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    Objective: To evaluate the clinical application of multi-slice spiral CT angiography(MSCTA) in the assessment of abdominal aortic disease. Methods: Fifty-four patients underwent multi-slice spiral CT angiography of abdomen. Contrast agent (Omnipaque 300 I g/L) 1.5 ml/kg was injected and the injection rate was 3 ml/s. The delay time was determined by bolus tracking technique,Tll level abdominal aorta was set as the target vessel and the threshold was 180-200 Hu, slice width was 3 mm and with a pitch of 4-6.Original data were transferred to working-station to perform functional reconstruction. Results: Ten cases were normal, twenty-eight cases were abdominal aortic aneurysms, five abdominal aortic dissecting aneurysms (Debakay type Ⅲ ) and eleven aortic sclerosis. SSD showed the body of aneurysm and the relationship between aneurysm and adjacent blood vessel, MIP better displayed calcification of blood vessel wall and condition of the stent, MPR demonstrated true and false lumen, rupture site of abdominal aorta intima and mural thrombus. Conclusion: MSCTA axial and reconstruction image can show the extent of abdominal aortic disease and the relationship with adjacent blood vessels. It is a safe, simple and non-invasive examination method.

  4. Prevalence of clinically important posterior fossa emissary veins on CT angiography

    Directory of Open Access Journals (Sweden)

    Yeliz Pekcevik

    2014-01-01

    Full Text Available Purpose: We assessed the prevalence of the clinically important posterior fossa emissary veins detected on computed tomography (CT angiography. Materials and Methods: A total of 182 consecutive patients who underwent 64-slice CT angiography were retrospectively reviewed to determine the clinically important posterior fossa emissary veins. Results: Of 166 patients, the mastoid emissary vein (MEV was not identified in 37 (22.3% patients. It was found bilaterally in 82 (49.4% and unilaterally in 47 (28.3% patients. Only six patients had more than one MEV that were very small (5 mm veins. The posterior condylar vein (PCV was not identified in 39 (23.5% patients. It was found bilaterally in 97 (58.4% and unilaterally in 30 (18.1% patients. Only 15 patients had a very large (>5 mm PCV. The petrosquamosal sinus (PSS was identified only in one patient (0.6% on the left side. The occipital sinus was found in two patients (1.2%. Conclusions: The presence of the clinically important posterior fossa emissary veins is not rare. Posterior fossa emissary veins should be identified and systematically reported, especially prior to surgeries involving the posterior fossa and mastoid region.

  5. Efficacy of 'fine' focal spot imaging in CT abdominal angiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Lawrence Chia Wei; Devapalasundaram, Ashwini; Ardley, Nicholas [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing, and Health Sciences, Victoria (Australia); Buchan, Kevin [Phillips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Huynh, Minh [RMIT University, School of Mathematical and Geospatial Sciences, Victoria (Australia)

    2014-12-15

    To assess the efficacy of fine focal spot imaging in calcification beam-hardening artefact reduction and vessel clarity on CT abdominal angiography (CTAA). Adult patients of any age and gender who presented for CTAA were included. Thirty-nine patients were examined with a standard focal spot size (SFSS) of 1 x 1 mm in the first 3 months while 31 consecutive patients were examined with a fine focal spot size (FFSS) of 1 x 0.5 mm in the following 3 months. Vessel clarity and calcification beam-hardening artefacts of the abdominal aorta, celiac axis, superior mesenteric artery, inferior mesenteric artery, renal arteries, and iliac arteries were assessed using a 5-point grading scale by two blinded radiologists randomly. Cohen's Kappa test indicated that on average, there was substantial agreement among reviewers for vessel wall clarity and calcification artefact grading. Mann-Whitney test showed that there was a significant difference between the two groups, with FFSS performing significantly better for vessel clarity (U, 6481.50; p < 0.001; r, 0.73) and calcification artefact reduction (U, 1916; p < 0.001; r, 0.77). Fine focus CT angiography produces images with better vessel wall clarity and less vessel calcification beam-hardening artefact. (orig.)

  6. Optimal sequence timing of CT angiography and perfusion CT in patients with stroke

    Energy Technology Data Exchange (ETDEWEB)

    Morhard, D., E-mail: morhard@nrad.de [Institute of Clinical Radiology, University of Munich, Munich (Germany); Institute of Diagnostic and Interventional Radiology, Neuroradiology and Nuclear Medicine, Klinikum Muenchen-Harlaching, Munich (Germany); Wirth, C.D. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Department of General Internal Medicine, University Hospital Inselspital, University of Bern, Bern (Switzerland); Reiser, M.F. [Institute of Clinical Radiology, University of Munich, Munich (Germany); Schulte-Altedorneburg, G. [Institute of Diagnostic and Interventional Radiology, Neuroradiology and Nuclear Medicine, Klinikum Muenchen-Harlaching, Munich (Germany); Ertl-Wagner, B. [Institute of Clinical Radiology, University of Munich, Munich (Germany)

    2013-06-15

    Objective: Standard stroke CT protocols start with non-enhanced CT followed by perfusion-CT (PCT) and end with CTA. We aimed to evaluate the influence of the sequence of PCT and CTA on quantitative perfusion parameters, venous contrast enhancement and examination time to save critical time in the therapeutic window in stroke patients. Methods and materials: Stroke CT data sets of 85 patients, 47 patients with CTA before PCT (group A) and 38 with CTA after PCT (group B) were retrospectively analyzed by two experienced neuroradiologists. Parameter maps of cerebral blood flow, cerebral blood volume, time to peak and mean transit time and contrast enhancements (arterial and venous) were compared. Results: Both readers rated contrast of brain-supplying arteries to be equal in both groups (p = 0.55 (intracranial) and p = 0.73 (extracranial)) although the extent of venous superimposition of the ICA was rated higher in group B (p = 0.04). Quantitative perfusion parameters did not significantly differ between the groups (all p > 0.18), while the extent of venous superimposition of the ICA was rated higher in group B (p = 0.04). The time to complete the diagnostic CT examination was significantly shorter for group A (p < 0.01). Conclusion: Performing CTA directly after NECT has no significant effect on PCT parameters and avoids venous preloading in CTA, while examination times were significantly shorter.

  7. Blunt polytrauma: evaluation with 64-section whole-body CT angiography.

    Science.gov (United States)

    Dreizin, David; Munera, Felipe

    2012-01-01

    Blunt polytrauma remains a leading cause of death and disability worldwide. With the major advances in computed tomography (CT) technology over the past decade, whole-body CT is increasingly recognized as the emerging standard for providing rapid and accurate diagnoses within the narrow therapeutic window afforded to trauma victims with multiple severe injuries. With a single continuous acquisition, whole-body CT angiography is able to demonstrate all potentially injured organs, as well as vascular and bone structures, from the circle of Willis to the symphysis pubis. As its use becomes more widespread, the large volume of information inherent to whole-body CT poses new challenges to radiologists in providing efficient and timely interpretation. An awareness of trauma scoring systems and injury mechanisms is essential to maintain an appropriate level of suspicion in the search for multiple injuries, and the use of multiplanar reformation and three-dimensional postprocessing techniques is important to maximize efficiency in the search. Knowledge of the key injuries that require urgent surgical or percutaneous intervention, including major vascular injuries and active hemorrhage, diaphragmatic rupture, unstable spinal fractures, pancreatic injuries with ductal involvement, and injuries to the mesentery and hollow viscera, is also necessary.

  8. Prostatic arterial supply: demonstration by multirow detector Angio CT and Catheter Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Bilhim, Tiago [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Pisco, Joao M. [Hospital Saint Louis, Interventional Radiology, Lisbon (Portugal); Universidade Nova de Lisboa, Departamento Universitario de Radiologia, Faculdade de Ciencias Medicas, Lisbon (Portugal); Furtado, Andrea; Casal, Diogo; Pais, Diogo; O' Neill, Joao E.G. [Departamento Universitario de Anatomia, Faculdade de Ciencias Medicas, Universidade Nova de Lisboa, Lisbon (Portugal); Campos Pinheiro, Luis [Universidade Nova de Lisboa, Departamento Universitario de Urologia, Faculdade de Ciencias Medicas, Lisbon (Portugal)

    2011-05-15

    To evaluate the prostatic arterial supply with multidetector Angio CT and Digital Subtraction Angiography (DSA). DSA was performed in 21 male patients (7 of these also underwent Pelvic Angio CT); a further 4 patients only underwent Angio CT. Prostatic arteries were classified according to their origin, direction, number of pedicles, termination and anastomoses with surrounding arteries in 50 pelvic sides. The most frequent origin was the internal pudendal artery (n = 28; 56%) with the common gluteal-pudendal trunk the next commonest (n = 14; 28%). Less frequent origins were the obturator artery (n = 6; 12%) or the inferior gluteal artery (n = 2; 4%). Two separate vascular pedicles were found in 12 pelvic sides (24%). There were anastomoses with the termination of the internal pudendal artery in 24% of cases (n = 12), with the contra-lateral prostatic arteries in 6 cases (12%), and to the superior vesical artery in 4 cases (8%). Defining prostatic artery origin and direction is paramount to allow selective catheterisation. Angio CT is very useful as a pre-intervention tool. The number of independent vascular pedicles and the presence of anastomoses with surrounding arteries should be taken into account when planning prostatic arterial embolisation. (orig.)

  9. Combined CT Angiography and CT Venography in Thromboembolic disease: clinical impact; Angio TC y flebo TC combinados en el diagnostico de la enfermedad tramboembolica: impacto clinico

    Energy Technology Data Exchange (ETDEWEB)

    Bouzas, R.; Migueles, Y.; Gomez, S.; Mallo, R.; Garcia-Tejedor, J. L.; Diaz Vega, M. J. [Complejo Hospitalario Xerar-Cies. Vigo. Pontevedra (Spain)

    2002-07-01

    Combined CT Venography and Pulmonary Angiography was described in 1998 as a tool for diagnostic Thromboembolic Disease. The purpose is to relate our own experience with this technique in a population with suspected pulmonary embolism. 46 consecutive patients with suspected pulmonary embolism underwent combined CT Venography after Pulmonary CT Angiography to depict Deep Venous Thrombosis (DVT). CT Venography where obtained with a 3 minutes delay from injection, without additional intravenous contrast, from upper abdomen to fibular head. A prospective study from emergency reports where used. The reports where aimed by nine different radiologist at diary emergency room (images where not retrospective review). We report if a pulmonary embolus or deep venous thrombus or another alternative diagnostic where done. An endo luminal thrombus in any pulmonary arteries was assessed as a positive study for PE. A Thrombus in the leg veins or in an abdominal vein without diminished size of vein was assessed as an acute DVT. In those patients with a CT negative to Thromboembolic Disease was the clinician who decide if more proves where needed. Those patients without evidence in CT of Thromboembolic Disease where asked for symptoms related to the episode in a 3 months period after initial CT. Patients free of symptoms for 3 months without anticoagulation therapy where considered true negative for CT. CT shows Thromboembolic Disease in 23 of 46 patients. 21PE, 14 DVT 2 of 14 patients with DVT don't show PE, CT excluded thromboembolic disease in 23 patients and in 15 of those patients an alternative diagnostic was shown. In 22 of those 23 patients CT excluded correctly Thromboembolic Disease. One patient result in a false negative CT, Pulmonary Angiography of that patient shows us a subsegmentary embolus. (Author) 9 refs.

  10. The Interobserver Agreement between Residents and Experienced Radiologists for Detecting Pulmonary Embolism and DVT with Using CT Pulmonary Angiography and Indirect CT Venography

    Energy Technology Data Exchange (ETDEWEB)

    Yavas, Ulas Savas; Calisir, Cuneyt; Ozkan; Ibrahim Ragip [Eskisehir Osmangazi University, Eskisehir (Turkmenistan)

    2008-12-15

    We wanted to prospectively evaluate the interobserver agreement between radiology residents and expert radiologists for interpreting CT images for making the diagnosis of pulmonary embolism (PE). We assessed 112 consecutive patients, from April 2007 to August 2007, who were referred for combined CT pulmonary angiography and indirect CT venography for clinically suspected acute PE. CT scanning was performed with a 64x0.5 collimation multi-detector CT scanner. The CT studies were initially interpreted by the radiology residents alone and then the CT images were subsequently interpreted by a consensus of the resident plus an experienced general radiologist and an experienced chest radiologist. Two of the 112 CTs were unable to be interpreted (1.7%). Pulmonary artery clots were seen on 36 of the thoracic CT angiographies (32%). The interobserver agreement between the radiology residents and the consensus interpretation was good (a kappa index of 0.73). All of the disagreements (15 cases) were instances of overcall by the resident on the initial interpretation. Deep venous thrombosis was detected in 72% (26 of 36) of the patients who had PE seen on thoracic CT. The initial and consensus interpretations of the CT venography images disagreed for two cases (kappa statistic: 0.96). It does not seem adequate to base the final long-term treatment of PE on only the resident's reading, as false positives occurred in 13% of such cases. Timely interpretation of the CT pulmonary angiography and CT venography images should be performed by experienced radiologists for the patients with suspected PE.

  11. Prospectively ECG Gated CT pulmonary angiography versus helical ungated CT pulmonary angiography: Impact on cardiac related motion artifacts and patient radiation dose

    Energy Technology Data Exchange (ETDEWEB)

    Shuman, William P., E-mail: wshuman@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Leipsic, Jonathon A., E-mail: JLeipsic@providencehealth.bc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Busey, Janet M., E-mail: jbonny@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Green, Douglas E., E-mail: dougreen@uw.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Pipavath, Sudhakar N., E-mail: snjp@u.wwashington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States); Hague, Cameron J., E-mail: cjhague@interchange.ubc.ca [University of British Columbia and St. Paul' s Hospital, Department of Radiology, 1081 Burrard Street, Vancouver, BC, V6Z1Y6 (Canada); Koprowicz, Kent M., E-mail: kentk@u.washington.edu [Department of Radiology, 1959 NE Pacific Street, Box 357115, Seattle, WA 98195 (United States)

    2012-09-15

    Objective: To compare prospectively ECG gated CT pulmonary angiography (CTPA) with routine helical ungated CTPA for cardiac related motion artifacts and patient radiation dose. Subjects and methods: Twenty patients with signs and symptoms suspicious for pulmonary embolism and who had a heart rate below 85 were scanned with prospectively ECG gated CTPA. These gated exams were matched for several clinical parameters to exams from twenty similar clinical patients scanned with routine ungated helical CTPA. Three blinded independent reviewers subjectively evaluated all exams for overall pulmonary artery enhancement and for several cardiac motion related artifacts, including vessel blurring, intravascular shading, and double line. Reviewers also measured pulmonary artery intravascular density and image noise. Patient radiation dose for each technique was compared. Fourteen clinical prospectively ECG gated CTPA exams from a second institution were evaluated for the same parameters. Results: Prospectively ECG gated CTPA resulted in significantly decreased motion-related image artifact scores in lung segments adjacent to the heart compared to ungated CTPA. Measured image noise was not significantly different between the two types of CTPA exams. Effective dose was 28% less for prospectively ECG gated CTPA (4.9 mSv versus 6.8 mSv, p = 0.02). Similar results were found in the prospectively ECG gated exams from the second institution. Conclusion: Compared to routine helical ungated CTPA, prospectively ECG gated CTPA may result in less cardiac related motion artifact in lung segments adjacent to the heart and significantly less patient radiation dose.

  12. Dose reduction in spiral CT angiography of thoracic outlet syndrome by anatomically adapted tube current modulation

    Energy Technology Data Exchange (ETDEWEB)

    Mastora, I.; Remy-Jardin, M.; Remy, J. [Dept. of Radiology, University Center Hospital Calmette, Lille (France); Medical Research Group, Lille (France); Suess, C.; Scherf, C. [Siemens Medical Systems, Forcheim (Germany); Guillot, J.P. [Dept. of Radiology, University Center Hospital Calmette, Lille (France)

    2001-04-01

    The aim of this study was to evaluate dose reduction in spiral CT angiography of the thoracic outlet by on-line tube-current control. Prospectively, 114 patients undergoing spiral CT angiography of the subclavian artery for thoracic outlet arterial syndromes were evaluated with and without tube-current modulation at the same session (scanning parameters for the two successive angiograms, one in the neutral position and one after the postural maneuver): 140 kV; 206 mA; scan time 0.75 s; collimation 3 mm; pitch = (1). The dose reduction system was applied in the neutral position in the first 92 consecutive patients and after postural maneuver in the remaining 22 consecutive patients. Dose reduction and image quality were analyzed in the overall study group (group 1; n = 114). The influence of the arm position was assessed in 44 of the 114 patients (group 2), matched by the transverse diameter of the upper thorax. The mean dose reduction was 33 % in group 1 (range 22-40 %) and 34 % in group 2 (range 26-40 %). In group 2 the only difference in image quality was a significantly higher frequency of graininess on low-dose scans compared with reference scans whatever the patient's arm position, graded as minimal in 38 of the 44 patients (86 %). When the low-dose technique was applied after postural maneuver in group 2: (a) the mean dose reduction was significantly higher (35 vs 32 % in the neutral position; p = 0.006); (b) graininess was less frequent (82 vs 91 % in the neutral position); and (c) the percentage of graininess graded as minimal was significantly higher (83 vs 70 % in the neutral position; p = 0.2027). On-line tube-current modulation enables dose reduction on high-quality, diagnostic spiral CT angiograms of the thoracic outlet and should be applied during data acquisition in the neutral position and after postural maneuver for optimal use. (orig.)

  13. Low-dose CT pulmonary angiography on a 15-year-old CT scanner: a feasibility study

    Directory of Open Access Journals (Sweden)

    Moritz Kaup

    2016-12-01

    Full Text Available Background Computed tomography (CT low-dose (LD imaging is used to lower radiation exposure, especially in vascular imaging; in current literature, this is mostly on latest generation high-end CT systems. Purpose To evaluate the effects of reduced tube current on objective and subjective image quality of a 15-year-old 16-slice CT system for pulmonary angiography (CTPA. Material and Methods CTPA scans from 60 prospectively randomized patients (28 men, 32 women were examined in this study on a 15-year-old 16-slice CT scanner system. Standard CT (SD settings were 100 kV and 150 mAs, LD settings were 100 kV and 50 mAs. Attenuation of the pulmonary trunk, various anatomic landmarks, and image noise were quantitatively measured; contrast-to-noise ratios (CNR and signal-to-noise ratios (SNR were calculated. Three independent blinded radiologists subjectively rated each image series using a 5-point grading scale. Results CT dose index (CTDI in the LD series was 66.46% lower compared to the SD settings (2.49 ± 0.55 mGy versus 7.42 ± 1.17 mGy. Attenuation of the pulmonary trunk showed similar results for both series (SD 409.55 ± 91.04 HU; LD 380.43 HU ± 93.11 HU; P = 0.768. Subjective image analysis showed no significant differences between SD and LD settings regarding the suitability for detection of central and peripheral PE (central SD/LD, 4.88; intra-class correlation coefficients [ICC], 0.894/4.83; ICC, 0.745; peripheral SD/LD, 4.70; ICC, 0.943/4.57; ICC, 0.919; all P > 0.4. Conclusion The LD protocol, on a 15-year-old CT scanner system without current high-end hardware or post-processing tools, led to a dose reduction of approximately 67% with similar subjective image quality and delineation of central and peripheral pulmonary arteries.

  14. Impact of routine cerebral CT angiography on treatment decisions in infective endocarditis.

    Directory of Open Access Journals (Sweden)

    Marwa Sayed Meshaal

    Full Text Available Infective endocarditis (IE is commonly complicated by cerebral embolization and hemorrhage secondary to intracranial mycotic aneurysms (ICMAs. These complications are associated with poor outcome and may require diagnostic and therapeutic plans to be modified. However, routine screening by brain CT and CT angiography (CTA is not standard practice. We aimed to study the impact of routine cerebral CTA on treatment decisions for patients with IE.From July 2007 to December 2012, we prospectively recruited 81 consecutive patients with definite left-sided IE according to modified Duke's criteria. All patients had routine brain CTA conducted within one week of admission. All patients with ICMA underwent four-vessel conventional angiography. Invasive treatment was performed for ruptured aneurysms, aneurysms ≥ 5 mm, and persistent aneurysms despite appropriate therapy. Surgical clipping was performed for leaking aneurysms if not amenable to intervention.The mean age was 30.43 ± 8.8 years and 60.5% were males. Staph aureus was the most common organism (32.3%. Among the patients, 37% had underlying rheumatic heart disease, 26% had prosthetic valves, 23.5% developed IE on top of a structurally normal heart and 8.6% had underlying congenital heart disease. Brain CT/CTA revealed that 51 patients had evidence of cerebral embolization, of them 17 were clinically silent. Twenty-six patients (32% had ICMA, of whom 15 were clinically silent. Among the patients with ICMAs, 11 underwent endovascular treatment and 2 underwent neurovascular surgery. The brain CTA findings prompted different treatment choices in 21 patients (25.6%. The choices were aneurysm treatment before cardiac surgery rather than at follow-up, valve replacement by biological valve instead of mechanical valve, and withholding anticoagulation in patients with prosthetic valve endocarditis for fear of aneurysm rupture.Routine brain CT/CTA resulted in changes in the treatment plan in a significant

  15. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose

  16. Cardiovascular CT angiography in neonates and children : Image quality and potential for radiation dose reduction with iterative image reconstruction techniques

    NARCIS (Netherlands)

    Tricarico, Francesco; Hlavacek, Anthony M.; Schoepf, U. Joseph; Ebersberger, Ullrich; Nance, John W.; Vliegenthart, Rozemarijn; Cho, Young Jun; Spears, J. Reid; Secchi, Francesco; Savino, Giancarlo; Marano, Riccardo; Schoenberg, Stefan O.; Bonomo, Lorenzo; Apfaltrer, Paul

    2013-01-01

    To evaluate image quality (IQ) of low-radiation-dose paediatric cardiovascular CT angiography (CTA), comparing iterative reconstruction in image space (IRIS) and sinogram-affirmed iterative reconstruction (SAFIRE) with filtered back-projection (FBP) and estimate the potential for further dose reduct

  17. Whole-brain CT digital subtraction angiography of cerebral dural arteriovenous fistula using 320-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Hirokazu; Momoshima, Suketaka; Kuribayashi, Sachio [Keio University, Department of Diagnostic Radiology, School of Medicine, Tokyo (Japan); Akiyama, Takenori [Keio University, Department of Neurosurgery, School of Medicine, Tokyo (Japan)

    2013-07-15

    The purpose of this study was to evaluate the usefulness of CT digital subtraction angiography (CTDSA) by using 320-detector row CT in the diagnosis and classification of cerebral dural arteriovenous fistula (dAVF) and comparing it with DSA as the standard reference. A total of 29 CTDSA/DSA from 25 patients with dAVF were retrospectively evaluated by two neuroradiologists. The presence, Cognard classification, and feeding arteries of dAVFs on CTDSA were assessed according to DSA. DSA depicted 33 dAVFs in 28 cases. By consensus reading, CTDSA correctly detected 32 dAVFs in 27 cases and properly graded 31 lesions. The intermodality agreement for the presence and classification of dAVFs was excellent (kappa = 0.955 and 0.921, respectively). CTDSA detected 77 of 109 feeding arteries (70.6 %) in 25 cases. The intermodality agreement for the feeding arteries was good (kappa = 0.713). Although CTDSA is limited in temporal and spatial resolution in comparison with DSA, it is an effective non-invasive tool for the detection and classification of dAVF. (orig.)

  18. Diagnostic accuracy of dual-source CT coronary angiography in patients with atrial fibrillation: Meta analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Zhi-wei [Department of Health Statistics, School of Public Health, Fourth Military Medical University, No. 169, Changle West Road, Xi’an, Shaanxi 710032 (China); Xu, Lin [Department of Medical Cardiology, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui; Ding, Juan; Li, Li [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jin, Zhi-tao [Department of Cardiology, General Hospital of the Second Artillery, Beijing 100088 (China)

    2013-10-01

    Rationale and objective: To synthesize the available data to underscore the diagnostic accuracy of dual-source CT (DSCT) coronary angiography in patients with atrial fibrillation (AF). Materials and methods: We searched in the electronic databases of PubMed for all published studies that examined patients with AF using DSCT. We used an exact binomial rendition of the bivariate mixed-effects regression model to synthesize the diagnostic data. Results: The positive and negative likelihood ratios (LRs) at the patient level were 6.0 (CI, 3.6–10.1) and 0.03(CI, 0.004–0.2), respectively. The negative predictive values higher than 90% were available for a CAD prevalence <78%. The pooled vessel- and segment-level estimates showed higher positive and negative LRs than the patient-level estimates (15.3 [CI, 9.8–23.9] and 0.1 [CI, 0.07–0.3]; 25.1 [CI, 10.8–58.5] and 0.2 [CI, 0.2–0.3], respectively). No statistically significant heterogeneity between studies and publication bias were found at the patient level estimate. A sensitivity analysis showed that no study influenced the pooled results larger than 0.02. Conclusions: Cardiac angiography with DSCT can be applied as an imaging test for ruling out CAD in patient with AF. However, DSCT angiography may be not an effective tool for risk stratification for the high negative LR at the artery and segment levels.

  19. Low tube voltage and low contrast material volume cerebral CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Song [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Xuzhou Medical College, School of Medical Imaging, Xuzhou, Jiangsu (China); Zhang, Long Jiang; Lu, Guang Ming [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Meinel, Felix G.; McQuiston, Andrew D. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States); Zhou, Chang Sheng; Qi, Li [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Schoepf, U.J. [Medical School of Nanjing University, Department of Medical Imaging, Jinling Hospital, Nanjing, Jiangsu (China); Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2014-07-15

    To evaluate the image quality, radiation dose and diagnostic accuracy of low kVp and low contrast material volume cerebral CT angiography (CTA) in intracranial aneurysm detection. One hundred twenty patients were randomly divided into three groups (n = 40 for each): Group A, 70 ml iodinated contrast agent/120 kVp; group B, 30 ml/100 kVp; group C, 30 ml/80 kVp. The CT numbers, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured in the internal carotid artery (ICA) and middle cerebral artery (MCA). Subjective image quality was evaluated. For patients undergoing DSA, diagnostic accuracy of CTA was calculated with DSA as reference standard and compared. CT numbers of ICA and MCA were higher in groups B and C than in group A (P < 0.01). SNR and CNR in groups A and B were higher than in group C (both P < 0.05). There was no difference in subjective image quality among the three groups (P = 0.939). Diagnostic accuracy for aneurysm detection among these groups had no statistical difference (P = 1.00). Compared with group A, the radiation dose of groups B and C was decreased by 45 % and 74 %. Cerebral CTA at 100 or 80 kVp using 30 ml contrast agent can obtain diagnostic image quality with a low radiation dose while maintaining the same diagnostic accuracy for aneurysm detection. (orig.)

  20. Clinical evaluation of automatic tube voltage selection in chest CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Tilo; Henry, Simon; Faivre, Jean-Baptiste; Yasunaga, Kanna; Bendaoud, Sofiane; Simeone, Ariana; Remy, Jacques [University Lille Nord de France, Department of Thoracic Imaging, Hospital Calmette (EA 2694), Lille (France); Duhamel, Alain [University Lille Nord de France, Department of Medical Statistics (EA 2694), Lille (France); Flohr, Thomas [Siemens Medical Systems, Department of Research and Development, Forchheim (Germany); Remy-Jardin, Martine [Hospital Calmette, Department of Thoracic Imaging, Lille cedex (France)

    2013-10-15

    To evaluate the clinical impact of automatic tube voltage selection on chest CT angiography (CTA). Ninety-three patients were prospectively evaluated with a CT protocol aimed at comparing two successive CTAs acquired under similar technical conditions except for the kV selection: (1) the initial CTA was systematically obtained at 120 kVp and 90 ref mAs; (2) the follow-up CTA was obtained with an automatic selection of the kilovoltage (Care KV; Siemens Healthcare) for optimised CTA. At follow-up, 90 patients (97 %) underwent CTA with reduced tube voltage, 100 kV (n = 26; 28 %) and 80 kV (n = 64; 69 %), resulting in a significant dose-length-product reduction (follow-up: 87.27; initial: 141.88 mGy.cm; P < 0.0001; mean dose reduction: 38.5 %) and a significant increase in the CNR at follow-up (follow-up: 11.5 {+-} 3.5 HU; initial: 10.9 {+-} 3.7 HU; P = 0.03). The increase in objective image noise at follow-up (follow-up: 23.2 {+-} 6.7 HU vs. 17.8 {+-} 5.1 HU; P < 0.0001) did not alter the diagnostic value of images. Automatic tube voltage selection reduced the radiation dose delivered during chest CT angiograms by 38.5 % while improving the contrast-to-noise ratio of the examinations. (orig.)

  1. Interleaving cerebral CT perfusion with neck CT angiography. Pt. II. Clinical implementation and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Oei, Marcel T.H.; Meijer, Frederick J.A.; Woude, Willem-Jan van der; Smit, Ewoud J.; Ginneken, Bram van; Manniesing, Rashindra; Prokop, Mathias [Radboud University Medical Centre, Department of Radiology and Nuclear Medicine, P.O. Box 9101, Nijmegen (Netherlands)

    2017-06-15

    Feasibility evaluation of the One-Step Stroke Protocol, which is an interleaved cerebral computed tomography perfusion (CTP) and neck volumetric computed tomography angiography (vCTA) scanning technique using wide-detector computed tomography, and to assess the image quality of vCTA. Twenty patients with suspicion of acute ischaemic stroke were prospectively scanned and evaluated with a head and neck CTA and with the One-Step Stroke Protocol. Arterial enhancement and contrast-to-noise ratio (CNR) in the carotid arteries was assessed. Three observers scored artefacts and image quality of the cervical arteries. The total z-coverage was evaluated. Mean enhancement in the carotid bifurcation was rated higher in the vCTA (595 ± 164 HU) than CTA (441 ± 117 HU). CNR was rated higher in vCTA. Image quality scores showed no significant difference in the region of the carotid bifurcation between vCTA and CTA. Lower neck image quality scores were slightly lower for vCTA due to artefacts, although not rated as diagnostically relevant. In ten patients, the origin of the left common carotid artery was missed by 1.6 ± 0.8 cm. Mean patient height was 1.8 ± 0.09 m. Carotid bifurcation and origin of vertebral arteries were covered in all patients. The One-Step Stroke Protocol is feasible with good diagnostic image quality of vCTA, although full z-coverage is limited in tall patients. (orig.)

  2. Dual-energy direct bone removal CT angiography for evaluation of intracranial aneurysm or stenosis: comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Yoshiyuki [National Cardiovascular Center, Department of Radiology, Osaka (Japan); St. Luke' s International Hospital, Department of Radiology, Tokyo (Japan); Uotani, Kensuke; Nakazawa, Tetsuro; Higashi, Masahiro; Yamada, Naoaki; Hori, Yoshiro; Kanzaki, Suzu; Fukuda, Tetsuya; Naito, Hiroaki [National Cardiovascular Center, Department of Radiology, Osaka (Japan); Itoh, Toshihide [Siemens Asahi Medical Technologies, Tokyo (Japan)

    2009-04-15

    Dual-energy CT can be applied for bone elimination in cerebral CT angiography (CTA). The aim of this study was to compare the results of dual-energy direct bone removal CTA (DE-BR-CTA) with those of digital subtraction angiography (DSA). Twelve patients with intracranial aneurysms and/or ICA stenosis underwent a dual-source CT in dual-energy mode. Post-processing software selectively removed bone structures using the two energy data sets. Three-dimensional images with and without bone removal were reviewed and compared to DSA. Dual-energy bone removal was successful in all patients. For 10 patients, bone removal was good and CTA maximum-intensity projection (MIP) images could be used for vessel evaluation. For two patients, bone removal was moderate with some bone remnants, but this did not inhibit the three-dimensional visualization. Three aneurysms adjacent to the skull base were only partially visible in conventional CTA but were fully visible in DE-BR-CTA. In five patients with ICA stenosis, DE-BR-CTA revealed the stenotic lesions on the MIP images. The correlation between DSA and DE-BR-CTA was good (R {sup 2}=0.822), but DE-BR-CTA led to an overestimation of stenosis. DE-BR-CTA was able to eliminate bone structure using only a single CT data acquisition and is useful to evaluate intracranial aneurysms and stenosis. (orig.)

  3. Application of Monte Carlo software in estimating patients' radiation dose during CCTA and confirmation by anthropomorphic phantom study%冠状动脉CT血管造影辐射剂量蒙特卡罗软件模拟计算及仿真体模验证

    Institute of Scientific and Technical Information of China (English)

    刘潇; 曾勇明; 彭盛坤; 郁仁强; 王杰; 孙静坤

    2014-01-01

    目的 应用蒙特卡罗(Monte Carlo)数学模型计算冠状动脉CT血管造影(CCTA)检查中患者的辐射剂量,并验证其准确性和有效性.方法 采用3组管电压(80、100、120 kV)对人体仿真体模行双源CT检查,使用数学模型软件(ImpactDose 2.0)模拟方法测量CCTA 3组管电压的患者器官吸收剂量并转换有效剂量,采用人体仿真体模置入热释光剂量计实验对数学模型模拟的结果进行验证.结果 除肺部以外,利用蒙特卡罗软件模拟计算的所有器官剂量值均小于利用仿真体模测量的;两种方法的相对误差在±50%以内.结论 利用蒙特卡罗软件模拟计算CCTA患者辐射剂量误差在可接受范围内,可用于估算CCTA检查辐射剂量水平.%Objective To evaluate the accuracy and efficiency of the Monte Carlo software in measuring the radiation dose to the patients who received the CCTA (Coronary Computed Tomography Angiography) examination.Methods A anthropomorphic chest phantom underwent CCTA using three scan parameters (tube voltage 80 kV,100 kV and 120 kV).Computer Software ImpactDose 2.0 was used to compute the chest organ dose on the basis of the three groups tube voltage CT scan characteristic,and the stimulation results of ImpactDose 2.0 software was verified by use of anthropomorphic phantom thermoluminescence dosimeter experiment method.Results For all the measured organs except for lung,the absorbed organ dose and effective dose of three groups of tube voltages of CCTA measured by the InpactDose 2.0 was lower than those as measured by anthropomorphic phantom study.The relative error of both methods was within ± 50%.Conclusions Monte Carlo software can be used to estimate the levels of radiation dose during CCTA examination with a tolerable error within the acceptable range.

  4. Adolescent Kawasaki disease: usefulness of 64-slice CT coronary angiography for follow-up investigation

    Energy Technology Data Exchange (ETDEWEB)

    Carbone, Iacopo; Cannata, David; Algeri, Emanuela; Galea, Nicola; Napoli, Alessandro; Catalano, Carlo; Passariello, Roberto; Francone, Marco [Sapienza University of Rome, Department of Radiological, Onchological and Anatomopathological Sciences, Policlinico Umberto I, Rome (Italy); De Zorzi, Andrea [Bambino Gesu Hospital, Cardiology Division, Rome (Italy); Bosco, Giovanna; D' Agostino, Rita [Sapienza University of Rome, Unit of Paediatric Cardiology, Policlinico Umberto I, Rome (Italy); Menezes, Leon [University College of London, Institute of Nuclear Medicine, London (United Kingdom)

    2011-09-15

    Kawasaki disease (KD) is a systemic vasculitis that mainly affects coronary arteries in children, and requires regular follow-up from the time of diagnosis. To evaluate the feasibility of 64-slice CT angiography (CTA) for follow-up of patients with KD using previously performed invasive catheter coronary angiography (CCA) as reference standard. The study group comprised 12 patients (age 17.6 {+-} 2.9 years, mean{+-}SD) with a diagnosis of KD and a previously performed CCA (interval, 32.6 {+-} 13.5 months) who underwent 64-slice cardiac CTA. The quality of the images for establishing the presence of coronary abnormalities was determined by two observers. The CTA findings were compared with those from the prior CCA. Adequate image quality was obtained in all patients. Mean effective dose for CTA was 6.56 {+-} 0.95 mSv. CTA allowed accurate identification, characterization and measurement of all coronary aneurysms (n = 32), stenoses (n = 3) and occlusions (n = 9) previously demonstrated by CCA. One patient with disease progression went on to have percutaneous coronary intervention. Coronary lesions were reliably evaluated by 64-slice CTA in the follow-up of compliant patients with KD, reducing the need for repeated diagnostic invasive CCA. Hence, in an adequately selected patient population, the role of CCA could be limited almost only to therapeutic procedures. (orig.)

  5. Differentiation of total occlusion and high-grade stenosis in coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Erffa, J. von; Ropers, D.; Pflederer, T.; Schmid, M.; Marwan, M.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Internal Medicine 2, Erlangen (Germany)

    2008-12-15

    In coronary CT angiography (CTA), both high-grade stenoses and total occlusions of a coronary artery may appear as a complete interruption of the contrast-enhanced lumen. Parameters to differentiate between occlusions and stenoses have not been systematically assessed. We evaluated 40 consecutive patients with a lesion demonstrating complete interruption of the contrast-enhanced lumen in coronary CTA and in whom invasive coronary angiography was available. Length of the vessel segment without luminal contrast enhancement; luminal enhancement proximal, in and distal to the lesion; degree of coronary remodelling; and the degree of lesion calcification were assessed by a blinded observer unaware of the invasive angiogram. Mean length of complete occlusions (n = 20; range 4-54 mm; mean 16.6 {+-} 3.5 mm) was significantly longer than for high-grade stenoses (n = 20; 2-8 mm; mean 4.6 {+-} 1.7 mm, p < 0.001). A lesion length {>=} 9 mm was 100% specific and 70% sensitive for an occlusion. No significant differences were found for vessel enhancement in or distal to the lesion, remodelling index or degree of calcification. Lesion length is the only parameter that may differentiate complete occlusions and high-grade stenoses in coronary CTA. For lesions {>=} 9 mm, an occlusion is very likely. (orig.)

  6. CT angiography for evaluation of cerebral vasospasm following acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Shankar, Jai Jai Shiva [Dalhousie University, Division of Neuroradiology, Department of Diagnostic Imaging, QEII Health Sciences Center, Halifax (Canada); Tan, Irene Y.L.; Krings, Timo; Terbrugge, Karel; Agid, Ronit [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2012-03-15

    Cerebral vasospasm (CV) is one of the most dreaded complications in patients who survive acute subarachnoid haemorrhage (SAH), and conventional cerebral angiography (DSA) is the gold standard for its diagnosis. We evaluated CT angiography (CTA) as a non-invasive alternative for diagnosis of CV and assessed if CTA could have a role in choosing appropriate treatment. Consecutive patients with SAH and suspected vasospasm were included when DSA was performed within 24 h from CTA. Two neuro-radiologists retrospectively analysed CTA and DSA studies independently. Assessment included presence of central and peripheral vasospasm and grading of severity of central CV. A treatment recommendation based on CTA was compared to actual treatment received. Final analysis included 34 patients. CTA was more accurate for diagnosis of central then for peripheral CV with high sensitivity (reader 1, 91%; reader 2, 92%), specificity (reader 1, 73%; reader 2, 90%), accuracy, positive predictive value and negative predictive value for central vasospasm. For grading the severity of CV CTA's sensitivity, specificity and accuracy were high for most central arteries. The reader's recommendation of angioplasty according to CTA was significantly predictive of actual receipt of angioplasty but overestimated actual receipt of triple H treatment. CTA is adequate for detecting central vasospasm in symptomatic SAH patients. A negative result should not prevent further investigation especially when evaluating arterial segments adjacent to metal artefacts from coils or clips. CTA is helpful in treatment decision making specifically regarding the need for balloon angioplasty. (orig.)

  7. Is urgent CT angiography necessary in cases of acute lower gastrointestinal bleeding?

    Science.gov (United States)

    Díaz, A Martín; Rodríguez, L Fernández; de Gracia, M Martí

    2017-01-06

    Acute lower gastrointestinal bleeding usually presents as hematochezia, rectal bleeding or melena and represents 1-2% of the medical appointments in the Emergency Services. Mortality reaches the 30-40% and it is highly related with the severity and associated comorbidity. Most clinical practice guidelines include colonoscopy at some point in the diagnostic and therapeutic process (urgent for severe cases and ambulatory for mild ones) and look for predictors of severity. In the last years, there have been numerous studies where is clear the relevance and complementarity of advanced diagnostic imaging techniques, gradually incorporated as an alternative or second step in severe cases. Therefore, we have made a review of current scientific evidence to establish a clinical prediction rule for optimal indication of CT angiography in these patients. However, future studies providing greater robustness and level of evidence are necessary.

  8. Helical CT angiography of renal arteries: two-years of experience; Angioscanographie helicoidale des arteres renales

    Energy Technology Data Exchange (ETDEWEB)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L. [Centre Hospitalier Universitaire, 59 - Lille (France)

    1997-08-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec). Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors).

  9. Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery: Diagnosis with CT Angiography

    Directory of Open Access Journals (Sweden)

    Guray Oncel

    2013-01-01

    Full Text Available Anomalous origin of the left coronary artery from the pulmonary artery (ALCAPA is a rare congenital anomaly. It is associated with early infant mortality and sudden death in adults. Traditionally, ALCAPA has been diagnosed by angiography or autopsy; however, the development of cardiac computed tomography (CT and magnetic resonance imaging (MRI has allowed noninvasive evaluation of the coronary anatomy by direct visualization of the origin of the left coronary artery (LCA from the pulmonary artery. We report a case of 10-year-old girl who has been on follow up for dilated cardiomyopathy for 4 years. The definitive diagnosis of ALCAPA is reached by multislice computed tomography (MSCT. The MSCT scan showed an anomalous origin of LCA from the pulmonary trunk, with a tortuous and dilated right coronary artery and right-to-left collateralization. Consequently, the patient was successfully treated with surgery.

  10. Myopericarditis diagnosed by a 64-slice coronary CT angiography "triple rule out" protocol

    Science.gov (United States)

    Ku, Bon S.; Halpern, Ethan J.

    2010-01-01

    We report a case of myopericarditis in a 30-year-old male complaining of shortness of breath. In an emergency department (ED) setting, the symptoms of myopericarditis may overlap with many disease entities and can be a challenging diagnosis to make. However, with the use of a 64-section coronary CT angiography in a “triple rule out” (TRO) protocol, we were able to detect a large pericardial effusion surrounding the heart and moderate global hypokinesis in the setting of normal-sized heart chambers and normal coronary arteries. We were further able to exclude pulmonary embolism and thoracic dissection. This is the first reported case of diagnosing myopericarditis using a TRO protocol. It demonstrates the usefulness of TRO in making an emergent diagnosis of myopericarditis while excluding other life-threatening diseases that can lead to earlier appropriate ED disposition and care. PMID:21373320

  11. Automatic segmentation of vertebral arteries in CT angiography using combined circular and cylindrical model fitting

    Science.gov (United States)

    Lee, Min Jin; Hong, Helen; Chung, Jin Wook

    2014-03-01

    We propose an automatic vessel segmentation method of vertebral arteries in CT angiography using combined circular and cylindrical model fitting. First, to generate multi-segmented volumes, whole volume is automatically divided into four segments by anatomical properties of bone structures along z-axis of head and neck. To define an optimal volume circumscribing vertebral arteries, anterior-posterior bounding and side boundaries are defined as initial extracted vessel region. Second, the initial vessel candidates are tracked using circular model fitting. Since boundaries of the vertebral arteries are ambiguous in case the arteries pass through the transverse foramen in the cervical vertebra, the circle model is extended along z-axis to cylinder model for considering additional vessel information of neighboring slices. Finally, the boundaries of the vertebral arteries are detected using graph-cut optimization. From the experiments, the proposed method provides accurate results without bone artifacts and eroded vessels in the cervical vertebra.

  12. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension.

    Science.gov (United States)

    Rajaram, Smitha; Swift, Andrew J; Capener, David; Telfer, Adam; Davies, Christine; Hill, Catherine; Condliffe, Robin; Elliot, Charles; Hurdman, Judith; Kiely, David G; Wild, Jim M

    2012-02-01

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall.

  13. Diagnostic accuracy of contrast-enhanced MR angiography and unenhanced proton MR imaging compared with CT pulmonary angiography in chronic thromboembolic pulmonary hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Rajaram, Smitha [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Academic Unit of Radiology, C Floor, Royal Hallamshire Hospital, Sheffield (United Kingdom); Swift, Andrew J.; Wild, Jim M. [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Capener, David; Telfer, Adam [Unit of Academic Radiology, University of Sheffield, Sheffield (United Kingdom); Davies, Christine; Hill, Catherine [Sheffield Teaching Hospitals Trust, Department of Radiology, Sheffield (United Kingdom); Condliffe, Robin; Elliot, Charles; Kiely, David G. [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom); Sheffield Cardiovascular Biomedical Research Unit, Sheffield (United Kingdom); Hurdman, Judith [Sheffield Pulmonary Vascular Disease Unit, Royal Hallamshire Hospital, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield (United Kingdom)

    2012-02-15

    To evaluate the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) and the added benefit of unenhanced proton MR angiography compared with CT pulmonary angiography (CTPA) in patients with chronic thromboembolic disease (CTE). A 2 year retrospective study of 53 patients with chronic thromboembolic pulmonary hypertension who underwent CTPA and MRI for suspected pulmonary hypertension and a control group of 36 patients with no CT evidence of pulmonary embolism. The MRI was evaluated for CTE and the combined diagnostic accuracy of ce-MRA and unenhanced proton MRA was determined. CE-MRA generated lung perfusion maps were also assessed. The overall sensitivity and specificity of CE-MRA in diagnosing proximal and distal CTE were 98% and 94%, respectively. The sensitivity improved from 50% to 88% for central vessel disease when CE-MRA images were analysed with unenhanced proton MRA. The CE-MRA identified more stenoses (29/18), post-stenosis dilatation (23/7) and occlusions (37/29) compared with CTPA. The CE-MRA perfusion images showed a sensitivity of 92% for diagnosing CTE. CE-MRA has high sensitivity and specificity for diagnosing CTE. The sensitivity of CE-MRA for visualisation of adherent central and lobar thrombus significantly improves with the addition of unenhanced proton MRA which delineates the vessel wall. (orig.)

  14. Small vessel stents for intracranial angioplasty: in vitro evaluation of in-stent stenoses using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Trossbach, M.; Hartmann, M.; Braun, C.; Sartor, K.; Haehnel, S. [Division of Neuroradiology of the Department of Neurology, University of Heidelberg Medical Center, Im Neuenheimer Feld 400, 69120, Heidelberg (Germany)

    2004-06-01

    Our aim was to determine whether CT angiography is suitable for the evaluation of in-stent restenoses in small vessel stents for intracranial angioplasty. Therefore, we simulated stenoses with degrees of 25, 50, 75 and 90% in a total of 12 stents with different designs (MEDTRONIC AVE; ABBOT BioDivYsio, GUIDANT Neurolink, TERUMO Tsunami, COOK V-Flex Plus) and sizes (3.0 mm, 4.0 mm). For each stenosis, the apparent stenotic degree (ASD) was measured by CT angiography. Subjective (viewing at the CT images) and objective (acquisition of a density profile) evaluations were made after the stents were filled with a solution of 0.9% NaCl and with a diluted contrast medium. It was not possible to visualize the patent lumen in any of the stenotic stent segments by viewing at the CT images. After objective evaluation, the degree of the stenoses was generally overestimated. In the group with the 3.0-mm stents, ASD ranged from 73.6 to 100% in 25% degree stenoses. With the exception of one stent, stenoses with a degree of more than 25% appeared as vessel obstruction (ASD =100%) in the 3.0-mm group. In the 4.0-mm group, the mean ASD was 60% for 25% degree stenoses, 76% for 50% degree stenoses, 91% for 75% degree stenoses and 96% for 95% degree stenoses. The minimum diameter of stents for differentiation between in-stent restenosis and vessel occlusion using CT angiography is 4.0 mm. In CT angiography, the degrees of in-stent stenoses are generally overestimated. The evaluation of in-stent restenoses only seems to be possible when CT angiographic images before and after contrast application are evaluated objectively by density profiles. (orig.)

  15. Deformable known component model-based reconstruction for coronary CT angiography

    Science.gov (United States)

    Zhang, X.; Tilley, S.; Xu, S.; Mathews, A.; McVeigh, E. R.; Stayman, J. W.

    2017-03-01

    Purpose: Atherosclerosis detection remains challenging in coronary CT angiography for patients with cardiac implants. Pacing electrodes of a pacemaker or lead components of a defibrillator can create substantial blooming and streak artifacts in the heart region, severely hindering the visualization of a plaque of interest. We present a novel reconstruction method that incorporates a deformable model for metal leads to eliminate metal artifacts and improve anatomy visualization even near the boundary of the component. Methods: The proposed reconstruction method, referred as STF-dKCR, includes a novel parameterization of the component that integrates deformation, a 3D-2D preregistration process that estimates component shape and position, and a polyenergetic forward model for x-ray propagation through the component where the spectral properties are jointly estimated. The methodology was tested on physical data of a cardiac phantom acquired on a CBCT testbench. The phantom included a simulated vessel, a metal wire emulating a pacing lead, and a small Teflon sphere attached to the vessel wall, mimicking a calcified plaque. The proposed method was also compared to the traditional FBP reconstruction and an interpolation-based metal correction method (FBP-MAR). Results: Metal artifacts presented in standard FBP reconstruction were significantly reduced in both FBP-MAR and STF- dKCR, yet only the STF-dKCR approach significantly improved the visibility of the small Teflon target (within 2 mm of the metal wire). The attenuation of the Teflon bead improved to 0.0481 mm-1 with STF-dKCR from 0.0166 mm-1 with FBP and from 0.0301 mm-1 with FBP-MAR - much closer to the expected 0.0414 mm-1. Conclusion: The proposed method has the potential to improve plaque visualization in coronary CT angiography in the presence of wire-shaped metal components.

  16. Utility of CT angiography in cervical spine trauma: analysis of radiation and cost

    Directory of Open Access Journals (Sweden)

    Waqas Shuaib

    2014-12-01

    Full Text Available Purpose: Vertebral artery injuries (VAIs can be seen in cervical injuries. This investigation was conducted to assess the impact of head and neck computed tomography (CT angiography (CTA on planning treatment of vertebral artery injuries, if these tests were ordered appropriately, and to estimate cost and associated exposure to radiation and contrast material. Methods: This retrospective review included all patients who underwent CT of the cervical spine and CTA of the head and neck from March 2011 to October 2012 at a single institution. Patients were divided into two groups, those with and those without cervical spine fracture appreciated on CT of the cervical spine. The frequency of vascular injury on CTA in those with a cervical fracture was assessed. The frequency of vascular injury treatment and modifications owed to a positive CTA of head and neck were also assessed. A study was considered appropriate if it was ordered in accordance with the modified Denver Screening criteria. Effective radiation dose (mSv was calculated by multiplying dose length product (DLP from the scanner with the standard conversion coefficient (k (k = 0.0021 mSv/mGy x cm.Results: In the 387 CTAs of head and neck, a cervical injury was recorded in 128 patients. Twenty CTA scans were correctly ordered for non-spinal indications, and 19 were ordered off protocol. CTA was found positive in 1 patient for whom the imaging was off protocol and 1 for whom the clinical indication was non-cervical. There were 19 positive CTA cases of head and neck, none of which underwent surgical intervention. CTA was positive in 13 of 48 patients who had suffered a C2 fracture; this accounted for 13 of the 19 positive CTA studies (p < 0.01. Estimated fee for CTA was $3783, and radiation exposure was 4 mSv with a standard deviation (±1.3. Conclusion: CTA of head and neck ordered off an institutional imaging protocol has a low probability of being positive. Adherence to protocols for CTA of

  17. Spiral CT angiography and surgical correlations in the evaluation of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Preda, L.; Di Maggio, E.M.; La Fianza, A.; Dore, R.; Fulle, I.; Solcia, M.; Campani, R. [Istituto di Radiologia, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy); Gaetani, P.; Rodriguez y Baena, R. [Neurosurgery, Istituto Clinico ``Humanitas``, I-20089 Rozzano (Midway Islands) (Italy); Cecchini, A. [Servizio di Radiodiagnostica, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy); Infuso, L. [Neurochirurgia, Dipartimento di Chirurgia, IRCCS Policlinico S. Matteo, p.le C. Golgi, 2, I-27 100 Pavia (Italy)

    1998-06-02

    We investigated the accuracy of spiral computed tomography angiography (CTA) in the detection and study of intracranial aneurysms by comparing CTA with selective angiograms and surgical findings. Twenty-six patients (9 men and 17 women; mean age 53.1 {+-} 1.8 years) with suspected intracranial aneurysms were submitted to CTA (1- to 2-mm slices, pitch 1:1, 24 s, RI = 1) after a conventional CT examination showing subarachnoid hemorrhage (SAH) in 19 cases and during neuroradiological investigations performed for other reasons in 7 cases. One hundred twenty to 150 ml iodate contrast agent (0.3-0.4 gI/ml) were injected intravenously at 5 ml/s rate and with 12- to 25-s delay calculated with a preliminary test bolus. Three-dimensional shaded surface display (3D SSD) and maximum intensity projection (MIP) reconstructions were obtained from axial images. Then, within 48 h, all patients were submitted to digital subtraction angiography (DSA), with separate assessment of CTA and DSA findings. Twenty-two aneurysms shown by CTA were confirmed at DSA and surgery (true positives), whereas the vascular lesion was not confirmed at DSA in 2 cases (false positives). The presence of intracranial aneurysms was excluded at both CTA and subsequent DSA in 7 cases (true negatives) and there were no false negatives; sensitivity was 100 %, specificity 77.8 %, and diagnostic accuracy 93.5 %. Computed tomography angiography aneurysm location was confirmed at surgery in all cases, with very high accuracy in assessing the presence of an aneurysm neck (100 %). Computed tomography angiography accurately depicted the aneurysm shape in 20 of 22 cases, but failed to depict its multilobed nature in 2 cases. The mean aneurysm diameter calculated at CTA was 0.99 {+-} 0.12 cm vs 1.09 {+-} 0.11 cm at surgery (p < 0.01). The present results suggest that the high sensitivity of CTA, if confirmed by further studies, might help in avoiding having to resort to arteriography after negative CTA in SAH patients

  18. Value of automatic bone subtraction in cranial CT angiography: comparison of bone-subtracted vs. standard CT angiography in 100 patients

    Energy Technology Data Exchange (ETDEWEB)

    Morhard, Dominik; Fink, Christian; Becker, Christoph; Reiser, Maximilian F.; Nikolaou, Konstantin [Ludwig-Maximilians-University of Munich, Institute of Clinical Radiology, Munich (Germany)

    2008-05-15

    Non-contrast-enhanced cranial computed tomography (NECT) and CT angiography (CTA) are the most frequently used modalities in the triage of patients with acute ischemic and hemorrhagic stroke. CTA bone removal can improve the delineation of vasculature closely adjacent to bony structures, which is sometimes limited in standard CTA. The aim of this study was the evaluation of the clinical benefit of bone subtraction (BS) regarding delineation of cerebral vasculature, reading time and depiction of vascular pathologies compared to standard CTA without BS. A total of 100 patients who underwent NECT and supraaortic CTA on a 64-slice CT system were retrospectively included in the study. Bone removal was performed by subtraction of the NECT data from the CTA data using a dedicated workstation. Standard and BS CTA of each patient was reviewed for delineation of cerebral vasculature (grading scale from 1 = 'excellent delineation' to 10 = 'hardly any delineation'), reading time and depiction of vascular pathologies (standardized catalog) by two blinded readers. For BS data sets, the quality of BS was rated by a combination of the criteria complete bone removal, depiction of vascular structures and sufficient quality for diagnostic evaluation. The use of BS significantly reduced reading time from 4.60 min to 3.49 min (p < 0.001). Performing BS, the quality of vascular delineation of the cerebral arteries, cerebral veins and cavernous segment of the ICA increased significantly as compared to standard CTA (1.70 vs. 2.70; 2.60 vs. 4.12; 2.35 vs. 4.40, all p < 0.001). Consensus reading showed 41 pathologies in 35 patients. Diagnosis was missed or wrong overall in 15 cases, with 3 missed aneurysms (CTA: 2 vs. BS: 1), 8 wrong stenotic findings (CTA: 3 vs. BS: 5) and 4 missed partial thromboses (CTA: 2 vs. BS: 2). Performing BS in supraaortic CTA for the evaluation of cerebral vasculature reduces reading time and improves delineation of vessels. Diagnostic

  19. Multimodality evaluation of dural arteriovenous fistula with CT angiography, MR with arterial spin labeling, and digital subtraction angiography: case report.

    Science.gov (United States)

    Alexander, Matthew; McTaggart, Ryan; Santarelli, Justin; Fischbein, Nancy; Marks, Michael; Zaharchuk, Greg; Do, Huy

    2014-01-01

    Dural arteriovenous fistulae (DAVF) are cerebrovascular lesions with pathologic shunting into the venous system from arterial feeders. Digital subtraction angiography (DSA) has long been considered the gold standard for diagnosis, but advances in noninvasive imaging techniques now play a role in the diagnosis of these complex lesions. Herein, we describe the case of a patient with right-side pulsatile tinnitus and DAVF diagnosed using computed tomography angiography, magnetic resonance with arterial spin labeling, and DSA. Implications for imaging analysis of DAVFs and further research are discussed.

  20. Coronary computed tomography angiography using ultra-low-dose contrast media: radiation dose and image quality.

    Science.gov (United States)

    Komatsu, Sei; Kamata, Teruaki; Imai, Atsuko; Ohara, Tomoki; Takewa, Mitsuhiko; Ohe, Ryoko; Miyaji, Kazuaki; Yoshida, Junichi; Kodama, Kazuhisa

    2013-08-01

    To analyze the invasiveness and image quality of coronary CT angiography (CCTA) with 80 kV. We enrolled 181 patients with low body weight and low calcium level. Of these, 154 patients were randomly assigned to 1 of 3 groups: 280 HU/80 kV (n = 51); 350 HU/80 kV (n = 51); or 350 HU/120 kV (n = 52). The amount of contrast media (CM) was decided with a CT number-controlling system. Twenty-seven patients were excluded because of an invalid time density curve by timing bolus. The predicted amount of CM, volume CT dose index, dose-length product, effective dose, image noise, and 5-point image quality were measured. The amounts of CM for the 80 kV/280 HU, 80 kV/350 HU, and 120 kV/350 HU groups were 10 ± 4 mL, 15 ± 7 mL, and 30 ± 6 mL, respectively. Although image noise was greater at 80 than 120 kV, there was no significant difference in image quality between 80 kV/350 HU and 120 kV/350 HU (p = 0.390). There was no significant difference in image quality between 80 kV/280 HU and 80 kV/350 HU (4.4 ± 0.7 vs. 4.7 ± 0.4, p = 0.056). The amount of CM and effective dose was lower for 80 kV CCTA than for 120 kV CCTA. CCTA at 80 kV/280 HU may decrease the amount of CM and radiation dose necessary while maintaining image quality.

  1. Stent-assisted intracranial angioplasty: potentials and limitations of pre- and postinterventional CT angiography; Stentgestuetzte intrakranielle Angioplastie: Moeglichkeiten und Grenzen der prae- und postinterventionellen CT-Angiografie

    Energy Technology Data Exchange (ETDEWEB)

    Schloetzer, W.; Schmitz, B.L. [Universitaetsklinikum Ulm (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie; Huber, R. [Universitaetsklinikum Ulm (Germany). Klinik fuer Neurologie

    2009-02-15

    CT angiography (CTA) is a noninvasive technique for evaluating intracranial arterial stenoses and for following up on intracranial stents. We analyzed a series of patients to assess the capabilities of CTA with respect to preinterventional und postinterventional diagnostic imaging for stent-assisted intracranial angioplasty. We examined 8 patients with 9 symptomatic intracranial arterial stenoses before and after stent placement with CTA. CT angiographies were compared to the periprocedural conventional angiography with regard to the quality of the visualization as well as the dimensions of the identified stenoses and the implanted stents. The extent of the preinterventional intracranial stenoses identified with CTA differed between -15 % to + 12 % from conventional angiography. In any case we were able to assess stent position, expansion, and perfusion with postinterventional CTA. The mean residual stenosis after stent placement was 33 % (13 - 48 %) measured with conventional angiography and it was accurately estimated with a difference of {+-} 15 % in 5 of 9 stents by CTA. 4 residual stenoses were underestimated or overestimated between -20 % and + 26 %. Further CTA controls of several patients showed good visualization of in-stent neointimal hyperplasia. CTA is useful for stent planning and follow-up of symptomatic intracranial stenoses. Intracranial stents and their lumina are adequately visualized by CTA, especially in vertebrobasilar vessels. However, residual stenosis and restenosis especially in the intracranial internal carotid artery and in the presence of calcified plaques may be incorrectly estimated by CTA. In case of doubt patients must undergo invasive angiography. In summary the use of CTA is a possibility for the primary follow-up of intracranial stents. It cannot generally prevent further diagnostics, but it is a potential method for reducing invasive angiography. (orig.)

  2. The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries.

    Science.gov (United States)

    Kemerink, G J; De Haan, M W; Vasbinder, G B C; Frantzen, M J; Schultz, F W; Zoetelief, J; Jansen, J Th M; Van Engelshoven, J M A

    2003-09-01

    Patient radiation dose in angiography of the renal arteries was assessed and optimized after installing new radiological equipment. In three separate studies (n=50, 25 and 20) patient exposure was monitored in detail. For the first study default factory settings were used, for the second the number of digital subtraction angiography (DSA) images was halved and the X-ray beam filtering during fluoroscopy was increased, and for the third study filtering during DSA was increased as well. Standard projections were derived and used in Monte Carlo simulations to derive dose conversion coefficients to calculate effective dose from the dose-area product (DAP). Dose conversion coefficients were also calculated for CT angiography (CTA). Using default factory settings on the new angiography system, DAP, number of images and effective dose were much higher than on the replaced unit. For the studies given above, DAP was reduced from 144 Gy cm(2) to 65 Gy cm(2) to 32 Gy cm(2), and effective dose from 22 mSv to 11 mSv to 9.1 mSv, respectively. Effective dose due to CTA was 5.2 mSv. It is concluded that modern angiography systems, resulting in high customer satisfaction, may readily cause much higher patient exposure than older systems. These doses may also be much higher than necessary. Optimization before putting such systems into use is absolutely essential. Internationally accepted recommendations for image quality and technique factors in angiography would be of great help.

  3. Diagnosis of lower gastrointestinal bleeding by multi-slice CT angiography: A meta-analysis.

    Science.gov (United States)

    He, Bosheng; Yang, Jushun; Xiao, Jing; Gu, Jinhua; Chen, Feixiang; Wang, Lin; Zhao, Chengjin; Qian, Junbo; Gong, Shenchu

    2017-08-01

    To estimate the diagnostic value of multi-slice spiral CT angiography (CTA) in lower gastrointestinal bleeding by a meta-analysis. The relevant clinical studies on the diagnostic value of CTA were searched on PubMed, Embase and other electronic documents databases with the deadline of 2016 September. Language was limited to English. A diagnostic meta-analysis was performed by using Meta-DiSc software. The effect sizes included sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) and 95% confidence interval (CI). The Cochran-Q test and I(2) statistic based on χ(2) test were used for estimation of the heterogeneity. Meta-regression was performed to explore the source of heterogeneity. SROC curve was established. A total of 14 articles including 549 patients with lower gastrointestinal bleeding were enrolled in the meta-analysis. The combined PLR, NLR and DOR were respectively 8.149, 0.158 and 56.213. There were significant heterogeneities in all estimations but we could not find the sources by meta-regression based on study design, study location, CT slices and sample size. The AUC and Q index under the fixed effect model was respectively 0.9463 and 0.8856. The multi-slice CTA has high diagnostic value for lower gastrointestinal bleeding. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Prospective ECG-gated 320-row CT angiography of the whole aorta and coronary arteries

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yu.; Fan, Zhanming; Xu, Lei; Yang, Lin; Xin, Haiyan; Zhang, Nan [Capital Medical University, Department of Radiology, Beijing An Zhen Hospital, Beijing (China); Capital Medical University, Ministry of Education, The Key Laboratory of Remodeling-Related Cardiovascular Diseases, Beijing An Zhen Hospital, Beijing (China); Zhang, Zhaoqi [Capital Medical University, Department of Radiology, Beijing An Zhen Hospital, Beijing (China)

    2012-11-15

    To investigate the feasibility of using a prospective ECG-gated wide-volume protocol in CT angiography (CTA) of the whole aorta and coronary arteries (CA). A total of 61 consecutive patients with suspected acute aortic diseases underwent CTA of the whole aorta using a prospective ECG-gated wide-volume CT protocol without heart rate (HR) control. The exposure window was set at 40-50 % of R-R interval (HR {>=}70 bpm) or 70-80 % of R-R interval (HR <70 bpm) in a single heartbeat. The image quality of the ascending aorta, aortic valve and CA was evaluated for motion artefacts. The mean attenuation was measured at different levels of the aorta. The radiation dose and contrast medium volume were recorded. All of the examinations were performed successfully. The image quality was acceptable in the ascending aorta, aortic valve (100 %) and CA (94.4 %). The mean radiation dose was 18.42 {+-} 5.02 mSv. Of 61 patients, 14 were diagnosed with aortic aneurysm and 35 were diagnosed with aortic dissection or intramural haematoma. Coronary artery stenosis was detected in 12 patients. For patients with aortic diseases, CTA of the whole aorta using a prospective ECG-gated wide-volume protocol has the potential to provide additional information about the CA and aortic valve with lower radiation exposure. (orig.)

  5. Characteristics of coronary artery disease in symptomatic type 2 diabetic patients: evaluation with CT angiography

    Directory of Open Access Journals (Sweden)

    Zhu Zhi-yu

    2010-11-01

    Full Text Available Abstract Background Coronary artery disease (CAD is a common and severe complication of type 2 diabetes mellitus (DM. The aim of this study is to identify the features of CAD in diabetic patients using coronary CT angiography (CTA. Methods From 1 July 2009 to 20 March 2010, 113 consecutive patients (70 men, 43 women; mean age, 68 ± 10 years with type 2 DM were found to have coronary plaques on coronary CTA. Their CTA data were reviewed, and extent, distribution and types of plaques and luminal narrowing were evaluated and compared between different sexes. Results In total, 287 coronary vessels (2.5 ± 1.1 per patient and 470 segments (4.2 ± 2.8 per patient were found to have plaques, respectively. Multi-vessel disease was more common than single vessel disease (p p p p p = 0.855. Extent of CAD, types of plaques and luminal narrowing were not significantly different between male and female diabetic patients. Conclusions Coronary CTA depicted a high plaque burden in patients with type 2 DM. Plaques, which were mainly calcified, were more frequently detected in the proximal segment of the LAD artery, and increased attention should be paid to the significant prevalence of obstructive stenosis. In addition, DM reduced the sex differential in CT findings of CAD.

  6. Role of Early Arterial Phase Multislice Helical CT Angiography in Evaluation of Hepatocellular Carcinoma

    Institute of Scientific and Technical Information of China (English)

    TANGBinghang; HEYaqi; LILiangcai; HUANGDecheng; WURenguo; YUYuanlong

    2005-01-01

    Objective: To investigate the clinical application of early arterial phase multislice CT angiography (MSCTA) of hepatic vessels in evaluation of middle or advanced stage hepatocellular carcinoma.Methods: Trigger Bolus program was used to carry out MSCTA in early and late arterial phases and portal vein phase with single breath holding. Hepatic vessels were reconstructed from the original images of early arterial phase by post processing. The blood supply of tumor and normal liver tissue and the appearances of venous thrombosis and arteriovenous shunts were analyzed. Results: The MSCTA with early arterial phase could perfectly display the origin, shape and amount of feeding vessels to normal liver tissue and tumor in middle or advanced stage hepatocellular carcinoma. It had the ability of displaying the arteriovenous shunts better than that in conventional dual phased liver scanning. Conclusion: MSCTA of hepatic vessels with early arterial phase acquisition using multislice helical CT in middle or advance stage hepatocellular carcinoma has favorable and promising application. It can be used as an imaging method for comprehensive assessment of the hepatocellular carcinoma before treatment.

  7. Procedural success of CTO recanalization: Comparison of the J-CTO score determined by coronary CT angiography to invasive angiography.

    Science.gov (United States)

    Li, Yuehua; Xu, Nan; Zhang, Jiayin; Li, Minghua; Lu, Zhigang; Wei, Meng; Lu, Bin; Zhang, Yang

    2015-01-01

    The J-CTO score is based on invasive angiography, combines several parameters of chronic total coronary occlusions (CTO), and is well established to predict the likelihood of success of percutaneous recanalization. The purpose of this study was to evaluate and validate a J-CTOCT score derived from coronary computed tomography angiography (coronary CTA). Between April 2011 and December 2014, 159 consecutive patients were retrospectively included. All had at least one CTO in invasive angiography, had coronary CTA performed at an interval of no more than one week from invasive angiography, and had an attempt at percutaneous coronary intervention (PCI) following coronary CTA In parallel to the angiographic J-CTO score, the J-CTOCT score was determined by awarding one point each for a blunt vessel stump, bending > 45°, occlusion length ≥ 20 mm, presence of calcium covering > 50% of any vessel cross-section within the occlusion, or a previously failed attempt at PCI. a. Both scores were compared regarding their ability to predict successful recanalization. A total of 171 CTO lesions were analyzed. Intraobserver (k = 0.814, p CTO score (mean: 1.8 ± 1.3, r = 0.856, p CTO score (area under curve: 0.868, p CTO score. . Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. MULTIDETECTOR CT ANGIOGRAPHY V/S COLOUR DOPPLER ULTRASONOGRAPHY IN THE DIAGNOSIS OF PERIPHERAL ARTERIAL DISEASES OF LOWER EXTREMITIES

    Directory of Open Access Journals (Sweden)

    Rezia Udinoor Peedikayil

    2016-08-01

    ultrasound, CT angiography is used prior to any vascular intervention is required in peripheral arterial diseases.

  9. Prevalence and clinical significance of extravascular incidental findings in patients undergoing CT cervico-cerebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Crockett, Matthew Thomas, E-mail: crockettmt@gmail.com; Murphy, Blathnaid, E-mail: blathnaidmurphy@hotmail.com; Smith, Jennifer, E-mail: jennifer.js.smith@gmail.com; Kavanagh, Eoin Carl, E-mail: kavanaghec@gmail.com

    2015-08-15

    Highlights: • CT cervico-cerebral angiography (CTCCA) is a commonly performed study for assessment of vascular pathologies of head and neck. • This study assessed the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. • This study demonstrated the presence of clinically significant incidental findings in 14% of patients undergoing CTCCA with 8% of these findings deemed to be highly significant. 19% of patients with highly clinically significant findings did not receive appropriate follow up. • A standardised method of reporting incidental findings, such as that used in this paper is suggested to aid radiologists and referring physicians in recording and communicating these findings. - Abstract: Introduction: CT cervico-cerebral angiography (CTCCA) is now the first line diagnostic imaging modality for the majority of vascular pathologies of the head and neck with diagnostic value comparable to or better than traditional angiographic techniques. The aim of this study was to assess the prevalence, clinical significance and management of extravascular incidental findings detected on CTCCA. Materials and methods: A retrospective review of the CTCCA reports of 302 consecutive patients from 2009 to 2013 was undertaken. Extravascular incidental findings were classified, according to an adaptation of the CT colonography data and reporting system (CRADS), as EV1–EV4. EV1 = no incidental findings, EV2 = clinically insignificant incidental finding, EV3 = incidental finding of intermediate clinical significance, EV4 = highly clinically significant finding. Follow up of the electronic medical records of patients with EV3 or EV4 findings was undertaken to determine subsequent management. Results: Potentially clinically significant findings were demonstrated in 14.2% of patients with 8.6% of patients having a highly clinically significant finding. 4 incidental findings were confirmed to be malignant lesions and 5

  10. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  11. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Ming Yen [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada); The University of Hong Kong, Queen Mary Hospital, Department of Diagnostic Radiology, Hong Kong (China); Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T. [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2016-10-15

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  12. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    Energy Technology Data Exchange (ETDEWEB)

    Sabharwal, Rohan [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia)]. E-mail: rohan50000@yahoo.com; Vladica, Philip [Department of Radiology, Westmead Hospital, Sydney, NSW (Australia); Coleman, Patrick [Department of Renal Medicine, Westmead Hospital, Sydney, NSW (Australia)

    2007-03-15

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  13. Motion correction for improving the accuracy of dual-energy myocardial perfusion CT imaging

    Science.gov (United States)

    Pack, Jed D.; Yin, Zhye; Xiong, Guanglei; Mittal, Priya; Dunham, Simon; Elmore, Kimberly; Edic, Peter M.; Min, James K.

    2016-03-01

    Coronary Artery Disease (CAD) is the leading cause of death globally [1]. Modern cardiac computed tomography angiography (CCTA) is highly effective at identifying and assessing coronary blockages associated with CAD. The diagnostic value of this anatomical information can be substantially increased in combination with a non-invasive, low-dose, correlative, quantitative measure of blood supply to the myocardium. While CT perfusion has shown promise of providing such indications of ischemia, artifacts due to motion, beam hardening, and other factors confound clinical findings and can limit quantitative accuracy. In this paper, we investigate the impact of applying a novel motion correction algorithm to correct for motion in the myocardium. This motion compensation algorithm (originally designed to correct for the motion of the coronary arteries in order to improve CCTA images) has been shown to provide substantial improvements in both overall image quality and diagnostic accuracy of CCTA. We have adapted this technique for application beyond the coronary arteries and present an assessment of its impact on image quality and quantitative accuracy within the context of dual-energy CT perfusion imaging. We conclude that motion correction is a promising technique that can help foster the routine clinical use of dual-energy CT perfusion. When combined, the anatomical information of CCTA and the hemodynamic information from dual-energy CT perfusion should facilitate better clinical decisions about which patients would benefit from treatments such as stent placement, drug therapy, or surgery and help other patients avoid the risks and costs associated with unnecessary, invasive, diagnostic coronary angiography procedures.

  14. Prospective Coronary Heart Disease Screening in Asymptomatic Hodgkin Lymphoma Patients Using Coronary Computed Tomography Angiography: Results and Risk Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); M’Kacher, Radhia [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Lessard, Nathalie [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Koscielny, Serge [Biostatistics and Epidemiology Unit, Institut Gustave Roussy, Villejuif (France); Elfassy, Eric; Raoux, François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France); Carde, Patrice [Department of Hematology, Institut Gustave Roussy, Villejuif (France); Santos, Marcos Dos [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Margainaud, Jean-Pierre [Department of Head and Neck Surgery, Institut Gustave Roussy, Villejuif (France); Sabatier, Laure [Laboratory of Radiobiology and Oncology, Institut de Radiobiologie Cellulaire et Moleculaire/Direction des Sciences Vivantes/Commissariat Energie Atomique, Fontenay aux Roses (France); Ghalibafian, Mithra [Department of Radiation Oncology, Institut Gustave Roussy, Villejuif (France); Paul, Jean-François [Department of Radiology, Marie Lannelongue, Chatenay-Malabry (France)

    2014-05-01

    Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patients (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.

  15. Meta-Analysis of Diagnostic Performance of Coronary Computed Tomography Angiography, Computed Tomography Perfusion, and Computed Tomography-Fractional Flow Reserve in Functional Myocardial Ischemia Assessment Versus Invasive Fractional Flow Reserve.

    Science.gov (United States)

    Gonzalez, Jorge A; Lipinski, Michael J; Flors, Lucia; Shaw, Peter W; Kramer, Christopher M; Salerno, Michael

    2015-11-01

    We sought to compare the diagnostic performance of coronary computed tomography angiography (CCTA), computed tomography perfusion (CTP), and computed tomography (CT)-fractional flow reserve (FFR) for assessing the functional significance of coronary stenosis as defined by invasive FFR in patients with known or suspected coronary artery disease (CAD). CCTA has proved clinically useful for excluding obstructive CAD because of its high sensitivity and negative predictive value (NPV); however, the ability of CTA to identify functionally significant CAD has remained challenging. We searched PubMed/Medline for studies evaluating CCTA, CTP, or CT-FFR for the noninvasive detection of obstructive CAD compared with catheter-derived FFR as the reference standard. Pooled sensitivity, specificity, PPV, NPV, likelihood ratios, and odds ratio of all diagnostic tests were assessed. Eighteen studies involving a total of 1,535 patients were included. CTA demonstrated a pooled sensitivity of 0.92, specificity 0.43, PPV of 0.56, and NPV of 0.87 on a per-patient level. CT-FFR and CTP increased the specificity to 0.72 and 0.77, respectively (p = 0.004 and p = 0.0009) resulting in higher point estimates for PPV 0.70 and 0.83, respectively. There was no improvement in the sensitivity. The CTP protocol involved more radiation (3.5 mSv CCTA vs 9.6 mSv CTP) and a higher volume of iodinated contrast (145 ml). In conclusion, CTP and CT-FFR improve the specificity of CCTA for detecting functionally significant stenosis as defined by invasive FFR on a per-patient level; both techniques could advance the ability to noninvasively detect the functional significance of coronary lesions.

  16. Optimization of kV Selection on Third-generation High-pitch Dual-source Coronary CT Angiography Using Ultra-low Contrast Media Protocols in Patients with Body Mass Index between 20-30 kg/m(2) under Automatic Tube Voltage Selection.

    Science.gov (United States)

    Wang, Ming; Yi, Yan; Cao, Jian; Wang, Yining; Qi, Bing; Ma, Shuo; Wang, Yun

    2017-02-20

    Objective To investigate the application of automatic tube voltage selection (CARE-kV)coronary CT angiography (CCTA)using ultra-low contrast media (CM)protocols in patients with body mass index (BMI)between 20 kg/m(2) and 30 kg/m(2) on third-generation dual-source CT (DSCT). Methods We prospectively included 134 consecutive patients with BMI between 20 kg/m(2) and 30 kg/m(2)who underwent CARE-kV prospective high-pitch CCTA on third-generation DSCT using the ultra-low CM protocols and divided them into two groups according to the CARE-kV results:70 kV group(n=91):65 patients with normal BMI(20 kg/m(2)≤BMI≤25 kg/m(2))and 26 patients with high BMI(25 kg/m(2)image quality (IQ),and results of patients in each group and subgroup were evaluated and compared.ResultsThe ED of 70 kV group was(0.24±0.04)mSv,which was 53% lower(H=3.37,P=0.02)than that of 80 kV group [(0.51±0.05)mSv]. No significant difference of CNR and SNR had been found in normal BMI patients(H=1.81,P=0.23)and high BMI patients (H=0.91,P=0.84)among 70 kV group and 80 kV group,as well as the subjective IQ in normal BMI patients(Z=0.79,P=0.76)and high BMI patients (Z=0.77,P=0.81)among 70 kV group and 80 kV group. Conclusion sWhen patients with BMI between 20 kg/m(2) and 30 kg/m(2) receive CARE-kV prospective high-pitch CCTA on third-generation DSCT,the CARE-kV results for a portion of patients may be higher than other patients with the same BMI level,so as to guarantee the equivalent IQ. The CARE-kV can help to select the patients' optimal tube voltage value more accurately and reasonably.

  17. Diagnostic accuracy of dual-source CT coronary angiography with prospective ECG-triggering on different heart rate patients

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Ming-li; Lu, Bin; Han, Lei; Liu, Gang; Yu, Fang-Fang; Hou, Zhi-hui; Gao, Yang; Wang, Hong-yu; Jiang, Shiliang [Peking Union Medical College, Department of Radiology, Cardiovascular Institute and Fu Wai Hospital, Chinese Academy of Medical Sciences, Beijing (China); Wu, Run-ze; Johnson, Laura [CT Research Collaboration, Siemens Healthcare, Shang Hai (China); Yang, Yue-jin; Qiao, Shu-bin [Chinese Academy of Medical Sciences, Peking Union Medical College, Department of Cardiology, Division of Coronary Heart Disease, Cardiovascular Institute and Fu Wai Hospital, Beijing (China)

    2011-08-15

    To evaluate the diagnostic accuracy of dual-source CT (DSCT) prospective ECG-triggering coronary angiography in patients with different heart rate (HR). 103 patients with suspected coronary artery disease underwent DSCT prospective ECG-triggered coronary angiography and invasive coronary angiography (ICA). The patients were grouped by HR during CT scans: low HR ({<=}60 bpm, n = 34); medium HR (60 < HR {<=} 70 bpm, n = 36) and high HR (>70 bpm, n = 33). The sensitivity and specificity of DSCT in detecting {>=}50% stenosis were compared among subgroups where ICA was the gold standard. Image quality was scored using a 4-point scale. A total of 1,580 (95.9%) coronary artery segments were evaluable. Sensitivity and specificity were 82.8% and 98.4%, 88.3% and 98.7%, and 80.3% and 98.6% for different subgroups (all p > 0.05). The overall area under the curve of the receiver-operating characteristic analysis was 0.94. The image quality scores were 3.1 {+-} 0.3, 3.1 {+-} 0.3 and 3.0 {+-} 0.4 for subgroups (p > 0.05). The overall average effective radiation dose was 3.60 {+-} 1.60 mSv. DSCT coronary angiography with prospective ECG-triggering could be just as accurate in patients with medium to high HR compared to those with low HR. (orig.)

  18. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    Energy Technology Data Exchange (ETDEWEB)

    San Millan Ruiz, Diego, E-mail: dsanmil1@jhmi.ed [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States); Murphy, Kieran, E-mail: KMURPHY@jhmi.ed [Division of Interventional Neuroradiology, Department of Radiology, The Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States); Gailloud, Philippe, E-mail: pgailloud@cerebrovascular.ne [Division of Interventional Neuroradiology, Department of Radiology, Johns Hopkins Hospital, 600 North Wolfe Street, B-100, Baltimore, MD 21287 (United States)

    2010-06-15

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  19. Is CT angiography of the pulmonary arteries indicated in patients with high clinical probability of pulmonary embolism?

    Science.gov (United States)

    Martínez Montesinos, L; Plasencia Martínez, J M; García Santos, J M

    2017-06-30

    When a diagnostic test confirms clinical suspicion, the indicated treatment can be administered. A problem arises when the diagnostic test does not confirm the initially suspected diagnosis; when the suspicion is grounded in clinically validated predictive rules and is high, the problem is even worse. This situation arises in up to 40% of patients with high suspicion for acute pulmonary embolism, raising the question of whether CT angiography of the pulmonary arteries should be done systematically. This paper reviews the literature about this issue and lays out the best evidence about the relevant recommendations for patients with high clinical suspicion of acute pulmonary embolism and negative findings on CT angiography. It also explains the probabilistic concepts derived from Bayes' theorem that can be useful for ascertaining the most appropriate approach in these patients. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic tube, ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ...

  2. Triple-rule-out CT angiography for evaluation of acute chest pain and possible acute coronary syndrome.

    Science.gov (United States)

    Halpern, Ethan J

    2009-08-01

    Triple-rule-out (TRO) computed tomographic (CT) angiography can provide a cost-effective evaluation of the coronary arteries, aorta, pulmonary arteries, and adjacent intrathoracic structures for the patient with acute chest pain. TRO CT is most appropriate for the patient who is judged to be at low to intermediate risk for acute coronary syndrome (ACS) and whose symptoms may also be attributed to acute pathologic conditions of the aorta or pulmonary arteries. Although a regular cardiac rhythm remains an important factor in coronary CT image quality, newer CT scanners with 64 or more detector rows afford rapid electrocardiographically (ECG) gated imaging to provide high-quality TRO CT studies in patients with a heart rate of up to 80 beats per minute. Injection of iodinated contrast material ( 300 HU) and in the pulmonary arteries (> 200 HU). To limit radiation exposure, the TRO CT examination does not include the entire chest but is constrained to incorporate the aortic arch down through the heart. Scanning parameters, including prospective ECG tube current modulation and prospective ECG gating with the "step-and-shoot" technique, are tailored to reduce radiation exposure (optimally, 5-9 mSv). When performed with appropriate attention to timing and technique, TRO CT provides coronary image quality equal to that of dedicated coronary CT angiography and pulmonary arterial images that are free of motion artifact related to cardiac pulsation. In an appropriately selected emergency department patient population, TRO CT can safely eliminate the need for further diagnostic testing in over 75% of patients.

  3. Focal changes of the spleen in one case of Gaucher disease - assessed by ultrasonography, CT, MRI and angiography

    Energy Technology Data Exchange (ETDEWEB)

    Aspestrand, F.; Charania, B.; Scheel, B.; Kolmannskog, F.; Jacobsen, M. (Rikshospitalet, Oslo (Norway). Dept. of Diagnostic Radiology)

    1989-11-01

    Focal lesions of the spleen in one case of Gaucher disease are demonstrated by ultrasonography, CT, MRI and angiography. The sonographic and angiographic features differ from the findings presented in previous reports. The Gaucher manifestations in the spleen as demonstrated by CT, do not seem to have been reported previously. An earlier report on the MR findings in the liver and spleen in this disease did not disclose any focal abnormalities. In this case, ultrasonography and MRI revealed a targetlike configuration of the focal lesions. An attempt is made to analyze the more complex patterns disclosed by MRI against the background of the manifestations by the other imaging modalities and previous reports. (orig.).

  4. Placing two parallel catheters by Seldinger`s approach through the femoral artery for CT angiography and CT during arterioportography. Evaluation of efficacy and safety

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Kazuhiro; Goto, Yasuyuki; Saito, Toshitaka [Musashino Red Cross Hospital, Tokyo (Japan); Wakabayashi, Yukari; Abe, Kimihiko

    1998-02-01

    The purpose of this study was to evaluate the efficacy and safety of placing two parallel catheters by Seldinger`s approach through the femoral artery for CT angiography (CTA) and CT during arterioportography (CTAP). We performed an analysis of 30 patients. Two introducers were successfully placed in all cases. Only one minor complication was observed, a localized inguinal hematoma. The CTA/CTAP procedures were successful in all patients except six who had anatomical variations of the hepatic arterial supply. Our methods proved to be useful and safe for patients with standard hepatic arterial supply. (author)

  5. Dual-energy CT angiography of the lung in patients with suspected pulmonary embolism. Initial results

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C.; Michaely, H.J. [Inst. fuer Klinische Radiologie und Nuklearmedizin, Universitaetsklinikum Mannheim, Univ. Heidelberg (Germany); Inst. fuer Klinische Radiologie, Campus Grosshadern, Klinikum der Univ. Muenchen (Germany); Johnson, T.R.; Morhard, D.; Becker, C.; Reiser, M.; Nikolaou, K. [Inst. fuer Klinische Radiologie, Campus Grosshadern, Klinikum der Univ. Muenchen (Germany)

    2008-10-15

    To evaluate the feasibility of dual-energy CT angiography (CTA) of the lung in patients with suspected pulmonary embolism (PE). 24 patients with suspected PE were examined with a single-acquisition, dual-energy CTA protocol (A-system: 140 kV/65 mAsref, B-system: 80 kV/190 mAsref) on a dual-source CT system. Lung perfusion was visualized by color-coding voxels containing iodine and air using dedicated dual-energy post-processing software. Perfusion defects were classified by two blinded radiologists as being consistent or non-consistent with PE. Subjective image quality of perfusion maps and CTA was rated using a 5-point scale (1: excellent, 5: poor). The reading of a third independent radiologist served as the standard of reference for the diagnosis of PE. In all patients with PE (n = 4), perfusion defects classified as being consistent with PE were identified in lung areas affected by PE. Both readers did not record perfusion defects classified as being consistent with PE in any of the patients without PE. Thus, on a per patient basis the sensitivity and specificity for the assessment of PE was 100% for both readers. On a per segment basis the sensitivity and specificity ranged between 60 - 66.7% and 99.5 - 99.8%. The interobserver agreement was good (k = 0.81). Perfusion defects rated as non-consistent with PE were most frequently caused by streak artifacts from dense contrast material in the great thoracic vessels. The median score of the image quality of both the perfusion maps and CTA was 2. In conclusion, dual-energy CTA of pulmonary embolism is feasible and allows the assessment of perfusion defects caused by pulmonary embolism. Further optimization of the injection protocol is required to reduce artifacts from dense contrast material. (orig.)

  6. 3D-CT angiography in high-grade aneurysmal subarachnoid hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, Kenji; Suda, Yoshitaka; Shioya, Hitoshi; Shindo, Kenjiro [Yuri Kumiai General Hospital, Honjo, Akita (Japan)

    1998-03-01

    We analyzed the role of 3D-CT angiography (3D-CTA) in the management of high-grade patients with severe subarachnoid hemorrhage (SAH) who were classified as Grade 5 by the Hunt-Kosnik grading system. From February 1995 to January 1997, 86 out of 92 patients with SAH were studied using 3D-CTA. There were 30 Grade 5 SAH patients (32.6%) including 5 patients who arrived in cardiopulmonary arrest (CPA). There were 13 men and 17 women, ranging in age from 46 to 89 years. Two-thirds were older than age 65 years. All patients underwent CT scan and were diagnosed with SAH. Excluding 5 CPA patients and one other patient, the remaining 24 patients successfully underwent 3D-CTA. As a result, ruptured aneurysms responsible for the SAH were clearly delineated in 19 patients (79.2%), and their anatomical relationships to the surrounding vessels were easily assessed. There were 8 patients with ICA aneurysms, 5 with MCA aneurysms, 2 with ACoA aneurysms, 2 with VA aneurysms, 1 with distal ACA aneurysm and 1 with distal PICA aneurysm. Intracranial vessels were not seen in 4 patients, 3 of whom had huge intracerebral hematomas associated with severe SAH. Proximal clipping was performed in a 46-years-old man with dissecting VA aneurysm. He later gained consciousness and became a surgical candidate. A 62-years-old woman underwent coil embolization for the large ICPC aneurysm after the level of her consciousness improved slightly following ventricular drainage. In conclusion, 3D-CTA can be performed safely and has a high detection rate of ruptured aneurysm even in patients with severe SAH. The results from these studies may gain further insight into epidemiology of SAH and ruptured aneurysms. (author)

  7. Development and validation of intracranial thrombus segmentation on CT angiography in patients with acute ischemic stroke.

    Directory of Open Access Journals (Sweden)

    Emilie M M Santos

    Full Text Available Thrombus characterization is increasingly considered important in predicting treatment success for patients with acute ischemic stroke. The lack of intensity contrast between thrombus and surrounding tissue in CT images makes manual delineation a difficult and time consuming task. Our aim was to develop an automated method for thrombus measurement on CT angiography and validate it against manual delineation.Automated thrombus segmentation was achieved using image intensity and a vascular shape prior derived from the segmentation of the contralateral artery. In 53 patients with acute ischemic stroke due to proximal intracranial arterial occlusion, automated length and volume measurements were performed. Accuracy was assessed by comparison with inter-observer variation of manual delineations using intraclass correlation coefficients and Bland-Altman analyses.The automated method successfully segmented the thrombus for all 53 patients. The intraclass correlation of automated and manual length and volume measurements were 0.89 and 0.84. Bland-Altman analyses yielded a bias (limits of agreement of -0.4 (-8.8, 7.7 mm and 8 (-126, 141 mm3 for length and volume, respectively. This was comparable to the best interobserver agreement, with an intraclass correlation coefficients of 0.90 and 0.85 and a bias (limits of agreement of -0.1 (-11.2, 10.9 mm and -17 (-216, 185 mm3.The method facilitates automated thrombus segmentation for accurate length and volume measurements, is relatively fast and requires minimal user input, while being insensitive to high hematocrit levels and vascular calcifications. Furthermore, it has the potential to assess thrombus characteristics of low-density thrombi.

  8. Electrocardiogram-gated coronary CT angiography dose estimates using ImPACT.

    Science.gov (United States)

    Kobayashi, Masanao; Asada, Yasuki; Matsubara, Kosuke; Suzuki, Shouichi; Koshida, Kichiro; Matsunaga, Yuta; Haba, Tomonobu; Kawaguchi, Ai; Toyama, Hiroshi; Kato, Ryouichi

    2016-07-08

    The primary study objective was to assess radiation doses using a modified form of the Imaging Performance Assessment of Computed Tomography (CT) scanner (ImPACT) patient dosimetry for cardiac applications on an Aquilion ONE ViSION Edition scanner, including the Ca score, target computed tomography angiography (CTA), prospective CTA, continuous CTA/cardiac function analysis (CFA), and CTA/CFA modulation. Accordingly, we clarified the CT dose index (CTDI) to determine the relationship between heart rate (HR) and X-ray exposure. As a secondary objective, we compared radiation doses using modified ImPACT, a whole-body dosimetry phantom study, and the k-factor method to verify the validity of the dose results obtained with modified ImPACT. The effective dose determined for the reference person (4.66 mSv at 60 beats per minute (bpm) and 33.43 mSv at 90bpm) were approximately 10% less than those determined for the phantom study (5.28 mSv and 36.68 mSv). The effective doses according to the k-factor (0.014 mSv•mGy-1•cm-1; 2.57 mSv and 17.10 mSv) were significantly lower than those obtained with the other two methods. In the present study, we have shown that ImPACT, when modified for cardiac applications, can assess both absorbed and effective doses. The results of our dose comparison indicate that modified ImPACT dose assessment is a promising and practical method for evaluating coronary CTA.

  9. Spontaneous obliteration of MRI-silent cerebral angiomatosis revealed by CT angiography in a patient with Sturge-Weber syndrome.

    Science.gov (United States)

    Aguglia, Umberto; Latella, Maria Adele; Cafarelli, Franco; Le Piane, Emilio; Gangemi, Antonio; Labate, Angelo; Gambardella, Antonio; Quattrone, Aldo

    2008-01-15

    Type I Sturge-Weber syndrome (SWS) is a neurocutaneous syndrome characterized by facial port wine stain and ipsilateral leptomeningeal angiomatosis. It is commonly complicated by glaucoma and neurological disturbances including seizures, hemiparesis, transient stroke-like deficits, and behavioral problems. Gadolinium-enhanced MRI is the study of choice for demonstrating the leptomeningeal angiomatosis, and is particularly useful for making the diagnosis. Cerebral hematoma and spontaneous obliteration of cerebral angiomatosis have never been reported in SWS. We describe a patient with type I SWS in which a hemorrhage in the left temporal lobe was caused by an underlying angiomatosis. No arteriovenous malformations were detected by brain CT or gadolinium-enhanced MRI, whereas a small angiomatous nidus draining into an ectasic venous collector near the hematoma was disclosed by brain CT angiography. Carotid angiography, performed 3 years after the hemorrhage, demonstrated the spontaneous obliteration of the angioma. This description expands the phenotypic spectrum of type I SWS in which the occurrence of cerebral hemorrhage and MRI-silent cerebral angiomatosis should be included, and emphasizes the need of performing a brain CT angiography in SWS patients whose routine neuroimaging studies fail to detect potentially harmful vessel malformation.

  10. High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Beeres, Martin; Schell, Boris; Mastragelopoulos, Aristidis; Kerl, Josef Matthias; Gruber-Rouh, Tatjana; Lee, Clara; Siebenhandl, Petra; Bodelle, Boris; Zangos, Stephan; Vogl, Thomas J.; Jacobi, Volkmar; Bauer, Ralf W. [Clinic of the Goethe University, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Herrmann, Eva [Clinic of the Goethe University, Department of Biostatistics, Frankfurt (Germany)

    2012-01-15

    To investigate the feasibility, image quality and radiation dose for high-pitch dual-source CT angiography (CTA) of the whole aorta without ECG synchronisation. Each group of 40 patients underwent CTA either on a 16-slice (group 1) or dual-source CT device with conventional single-source (group 2) or high-pitch mode with a pitch of 3.0 (group 3). The presence of motion or stair-step artefacts of the thoracic aorta was independently assessed by two readers. Subjective and objective scoring of motion and artefacts were significantly reduced in the high-pitch examination protocol (p < 0.05). The imaging length was not significantly different, but the imaging time was significantly (p < 0.001) shorter in the high-pitch group (12.2 vs. 7.4 vs. 1.7 s for groups 1, 2 and 3). The ascending aorta and the coronary ostia were reliably evaluable in all patients of group 3 without motion artefacts as well. High-pitch dual-source CT angiography of the whole aorta is feasible in unselected patients. As a significant advantage over regular pitch protocols, motion-free imaging of the aorta is possible without ECG synchronisation. Thus, this CT mode bears potential to become a standard CT protocol before trans-catheter aortic valve implantation (TAVI). (orig.)

  11. Automatic detection of plaques with severe stenosis in coronary vessels of CT angiography

    Science.gov (United States)

    Dinesh, M. S.; Devarakota, Pandu; Kumar, Jitendra

    2010-03-01

    Coronary artery disease is the end result of the accumulation of atheromatous plaques within the walls of coronary arteries and is the leading cause of death worldwide. Computed tomography angiography (CTA) has been proved to be very useful for accurate noninvasive diagnosis and quantification of plaques. However, the existing methods to measure the stenosis in the plaques are not accurate enough in mid and distal segments where the vessels become narrower. To alleviate this, we propose a method that consists of three stages namely, automatic extraction of coronary vessels; vessels straightening; lumen extraction and stenosis evaluation. In the first stage, the coronary vessels are segmented using a parametric approach based on circular vessel model at each point on the centerline. It is assumed that centerline information is available in advance. Vessel straightening in the second stage performs multi-planar reformat (MPR) to straighten the curved vessels. MPR view of a vessel helps to visualize and measure the plaques better. On the straightened vessel, lumen and vessel wall are segregated using a nearest neighbor classification. To detect the plaques with severe stenosis in the vessel lumen, we propose a "Diameter Luminal Stenosis" method for analyzing the smaller segments of the vessel. Proposed measurement technique identifies the segments that have plaques and reports the top three severely stenosed segments. Proposed algorithm is applied on 24 coronary vessels belonging to multiple cases acquired from Sensation 64 - slice CT and initial results are promising.

  12. Multi-parametric ultrasound criteria for internal carotid artery disease - comparison with CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Barlinn, Kristian; Kepplinger, Jessica; Siepmann, Timo; Pallesen, Lars-Peder; Bodechtel, Ulf; Reichmann, Heinz; Puetz, Volker [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Floegel, Thomas [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neurology, Dresden (Germany); Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Kitzler, Hagen H. [Carl Gustav Carus University Hospital, Technische Universitaet Dresden, Department of Neuroradiology, Dresden (Germany); Alexandrov, Andrei V. [The University of Tennessee Health Science Center, Department of Neurology, Memphis, TN (United States)

    2016-09-15

    The German Society of Ultrasound in Medicine (known by its acronym DEGUM) recently proposed a novel multi-parametric ultrasound approach for comprehensive and accurate assessment of extracranial internal carotid artery (ICA) steno-occlusive disease. We determined the agreement between duplex ultrasonography (DUS) interpreted by the DEGUM criteria and CT angiography (CTA) for grading of extracranial ICA steno-occlusive disease. Consecutive patients with acute cerebral ischemia underwent DUS and CTA. Internal carotid artery stenosis was graded according to the DEGUM-recommended criteria for DUS. Independent readers manually performed North American Symptomatic Carotid Endarterectomy Trial-type measurements on axial CTA source images. Both modalities were compared using Spearman's correlation and Bland-Altman analyses. A total of 303 acute cerebral ischemia patients (mean age, 72 ± 12 years; 58 % men; median baseline National Institutes of Health Stroke Scale score, 4 [interquartile range 7]) provided 593 DUS and CTA vessel pairs for comparison. There was a positive correlation between DUS and CTA (r{sub s} = 0.783, p < 0.001) with mean difference in degree of stenosis measurement of 3.57 %. Bland-Altman analysis further revealed widely varying differences (95 % limits of agreement -29.26 to 22.84) between the two modalities. Although the novel DEGUM criteria showed overall good agreement between DUS and CTA across all stenosis ranges, potential for wide incongruence with CTA underscores the need for local laboratory validation to avoid false screening results. (orig.)

  13. Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Gaemperli, Oliver; Valenta, Ines; Schepis, Tiziano [University Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); Husmann, Lars; Scheffel, Hans; Desbiolles, Lotus; Leschka, Sebastian; Alkadhi, Hatem [University Hospital Zurich, Institute of Diagnostic Radiology, Zurich (Switzerland); Kaufmann, Philipp A. [University Hospital Zurich NUK C 32, Cardiovascular Center, Zurich (Switzerland); University of Zurich, Zurich Center for Integrative Human Physiology (ZIHP), Zurich (Switzerland)

    2008-06-15

    The aim of this study was to assess the prognostic value of 64-slice CT angiography (CTA) in patients with known or suspected coronary artery disease (CAD). Sixty-four-slice coronary CTA was performed in 220 patients [mean age 63 {+-} 11 years, 77 (35%) female] with known or suspected CAD. CTA images were analyzed with regard to the presence and number of coronary lesions. Patients were followed-up for the occurrence of the following clinical endpoints: death, nonfatal myocardial infarction, unstable angina, and coronary revascularization. During a mean follow-up of 14 {+-} 4 months, 59 patients (27%) reached at least one of the predefined clinical endpoints. Patients with abnormal coronary arteries on CTA (i.e., presence of coronary plaques) had a 1st-year event rate of 34%, whereas in patients with normal coronary arteries no events occurred (event rate, 0%, p < 0.001). Similarly, obstructive lesions ({>=}50% luminal narrowing) on CTA were associated with a high first-year event rate (59%) compared to patients without stenoses (3%, p < 0.001). The presence of obstructive lesions was a significant independent predictor of an adverse cardiac outcome. Sixty-four-slice CTA predicts cardiac events in patients with known or suspected CAD. Conversely, patients with normal coronary arteries on CTA have an excellent mid-term prognosis. (orig.)

  14. Optimal iodine dose for 3-dimensional multidetector-row CT angiography of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Ichikawa, Tomoaki, E-mail: ichikawa@yamanashi.ac.jp [Department of Radiology, University of Yamanashi, Yamanashi (Japan); Motosugi, Utaroh; Morisaka, Hiroyuki; Sou, Hironobu; Onohara, Kojiro; Sano, Katsuhiro; Araki, Tsutomu [Department of Radiology, University of Yamanashi, Yamanashi (Japan)

    2012-09-15

    Purpose: To clarify the optimal iodine dose of contrast material for 3-dimensional multidetector-row CT angiography (3D-MDCTA) of the venous vasculature of the liver using volume rendering technique. Materials and methods: This study included 103 patients who were randomly assigned to 5 contrast-enhanced MDCT protocol groups with different body-weight-tailored doses of contrast material: 500, 600, 630, 650, and 700 mgI/kg body weight. The arterial, portal, and hepatic parenchymal phases were obtained to evaluate enhancement values of the aorta, portal vein, and hepatic vein. Visualization of the portal and hepatic veins on the volume-rendering images of 3D-MDCTA was evaluated using a 5-point grade. Dunnett's test was used to compare the mean enhancement value and mean grades of image quality (700 mgI/kg dose group was control). Results: The mean enhancement values of portal and hepatic vein in the group with 500 and 600 mgI/kg were significantly lower than those of the control group. During visual assessment, a significantly lower mean grades were observed in 500 mgI/kg groups for the portal vein, and 500 and 600 mgI/kg groups for hepatic vein. There were no significant intergroup differences in mean enhancement values and visual assessment among the groups using 630 mgI/kg or more. Conclusion: Iodine doses of 630 mgI/kg was recommended for 3D-MDCTA.

  15. Aortic valve stenosis: non-invasive preoperative evaluation using 64-slice CT angiography.

    Science.gov (United States)

    Ciolina, F; Sedati, P; Zaccagna, F; Galea, N; Noce, V; Miraldi, F; Cavarretta, E; Francone, M; Carbone, I

    2015-10-01

    In patients affected by aortic valve stenosis (AS) it is mandatory to rule out coronary artery disease (CAD). The role of retrospectively ECG-gated 64-slice CT angiography (64-SCTA) was assessed in patients with AS referred for surgical valve replacement. Forty-two patients with AS underwent ECG-gated 64-SCTA of thoracic aorta, including the heart and coronary arteries, before surgical valve replacement. Images were evaluated by two independent readers and compared with surgical findings in terms of aortic valve calcification grading, valvular morphology, aortic valve annulus and sino-tubular junction diameters, and valvular area planimetry. Quantitative evaluation of cusps opening was also performed. Finally, the presence of CAD, thoracic aortic aneurysm and left ventricle hypertrophy were assessed. Visualization of the aortic valve without motion artefacts was possible in 38 patients (90.5%). Valvular morphology was correctly assessed in all cases (100%). 64-SCTA correctly determined aortic valve calcification grading and the aortic valve annulus and sinotubular junction diameters in 100% of cases. The aortic valve planimetric area was assessed in 38 cases (90.5%). Ascending aortic aneurysms requiring surgical replacement were detected in 12 patients (28.6%). Significant left ventricle hypertrophy was found in 30 patients (71%). Preoperative evaluation of patients undergoing surgical replacement for AS with 64-SCTA is feasible. 64-SCTA can rule out CAD and evaluate the status of the aortic valve and thoracic aorta in the same examination, obtaining relevant information for surgical planning.

  16. Pulmonary embolism in pregnancy: comparison of pulmonary CT angiography and lung scintigraphy.

    Science.gov (United States)

    Ridge, Carole A; McDermott, Shaunagh; Freyne, Bridget J; Brennan, Donal J; Collins, Conor D; Skehan, Stephen J

    2009-11-01

    The purpose of this study was to retrospectively compare the diagnostic adequacy of lung scintigraphy with that of pulmonary CT angiography (CTA) in the care of pregnant patients with suspected pulmonary embolism. Patient characteristics, radiology report content, additional imaging performed, final diagnosis, and diagnostic adequacy were recorded for pregnant patients consecutively referred for lung scintigraphy or pulmonary CTA according to physician preference. Measurements of pulmonary arterial enhancement were performed on all pulmonary CTA images of pregnant patients. Lung scintigraphy and pulmonary CTA studies deemed inadequate for diagnosis at the time of image acquisition were further assessed, and the cause of diagnostic inadequacy was determined. The relative contribution of the inferior vena cava to the right side of the heart was measured on nondiagnostic CTA images and compared with that on CTA images of age-matched nonpregnant women, who were the controls. Twenty-eight pulmonary CTA examinations were performed on 25 pregnant patients, and 25 lung scintigraphic studies were performed on 25 pregnant patients. Lung scintigraphy was more frequently adequate for diagnosis than was pulmonary CTA (4% vs 35.7%) (p = 0.0058). Pulmonary CTA had a higher diagnostic inadequacy rate among pregnant than nonpregnant women (35.7% vs 2.1%) (p lung scintigraphy was more reliable than pulmonary CTA in pregnant patients. Transient interruption of contrast material by unopacified blood from the inferior vena cava is a common finding at pulmonary CTA of pregnant patients.

  17. Evaluation of intracranial aneurysms with CT angiography: current status and future direction

    Science.gov (United States)

    Sato, Yutaka; Sickels, William; Quets, Jerome; Crosby, Daniel; Chang, Shereen; Cook-Granroth, Janice; Hoffman, Eric A.

    1997-05-01

    Purpose: To develop a valid, reliable and accurate system of measurement of intracranial aneurysm geometry using volumetric data obtained by CT angiography. Materials and methods: A simple model of lateral saccular aneurysm was created. Three models were prepared with different size of aneurysm sac and neck. Volumetric data was acquired using a Toshiba Xpress SX helical scanner. Geometry of an aneurysm model obtained by workstation linked to the scanner applying volume rendering display and dedicated UNIX based computer applying MPR based method. These results were compared with actual caliper measurements of the model. A clinical case of lateral aneurysm arising from the supraclinoid internal carotid artery was also studied. Results: Both the volume rendered image based method and MPR based method provided accurate geometric information of an aneurysm sac and its neck. Conclusions: Volume rendering technique requires editing by a well-informed operator and subjective, while the MPR based method is more objective and better suited for quantitative analysis. Using these mutually complimentary tools, critical geometric information of an aneurysm can be extracted from volumetric data provided by CTA.

  18. Multidetector-CT angiography in pulmonary embolism - can image parameters predict clinical outcome?

    Energy Technology Data Exchange (ETDEWEB)

    Heyer, Christoph M.; Lemburg, Stefan P.; Nicolas, Volkmar; Roggenland, Daniela [Berufsgenossenschaftliches Universitaetsklinikum Bergmannsheil GmbH, Ruhr-University of Bochum, Institute of Diagnostic Radiology, Interventional Radiology and Nuclear Medicine, Bochum (Germany); Knoop, Heiko [Berufsgenossenschaftliches Universitaetsklinikum Bergmannsheil GmbH, Medical Clinic III - Pneumology, Allergology, and Sleep Medicine, Bochum (Germany); Holland-Letz, Tim [Ruhr-University of Bochum, Department of Medical Informatics, Biometry and Epidemiology, Bochum (Germany)

    2011-09-15

    To assess if pulmonary CT angiography (CTA) can predict outcome in patients with pulmonary embolism (PE). Retrospective analysis of CTA studies of patients with PE and documentation of pulmonary artery (PA)/aorta ratio, right ventricular (RV)/left ventricular (LV) ratio, superior vena cava (SVC) diameter, pulmonary obstruction index (POI), ventricular septal bowing (VSB), venous contrast reflux (VCR), pulmonary infarction and pleural effusion. Furthermore, duration of total hospital stay, necessity for/duration of ICU therapy, necessity for mechanical ventilation and mortality were recorded. Comparison was performed by logistic/linear regression analysis with significance at 5%. 152 patients were investigated. Mean duration of hospital stay was 21 {+-} 24 days. 66 patients were admitted to the ICU; 20 received mechanical ventilation. Mean duration of ICU therapy was 3 {+-} 8 days. Mortality rate was 8%. Significant positive associations of POI, VCR and pulmonary infarction with necessity for ICU therapy were shown. VCR was significantly associated with necessity for mechanical ventilation and duration of ICU treatment. Pleural effusions were significantly associated with duration of total hospital stay whereas the RV/LV ratio correlated with mortality. Selected CTA findings showed significant associations with the clinical course of PE and may thus be used as predictive parameters. (orig.)

  19. In vivo small-animal imaging using micro-CT and digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Badea, C T; Johnson, G A [Center for In Vivo Microscopy, Department of Radiology, Duke University, Durham, NC 27710 (United States); Drangova, M; Holdsworth, D W [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, ON N6A 5K8 (United States)], E-mail: Cristian.Badea@duke.edu

    2008-10-07

    Small-animal imaging has a critical role in phenotyping, drug discovery and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo x-ray based small-animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging. (topical reviews)

  20. Impact of multidetector CT-angiography on the emergency management of severe hemoptysis

    Energy Technology Data Exchange (ETDEWEB)

    Chalumeau-Lemoine, Ludivine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Khalil, Antoine, E-mail: antoine_khalil@yahoo.fr [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Pathological Angiogenesis and Vessel Normalization, Center for Interdisciplinary Research in Biology, CNRS UMR 7241/INSERM U1050, Collège de France, Paris (France); Prigent, Hélène [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Carette, Marie-France [Service de Radiologie, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Fartoukh, Muriel [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France); Université Pierre et Marie Curie, Paris VI (France); Parrot, Antoine [Service de Pneumologie et Réanimation, Hôpital Tenon, HUEP, APHP, 4 rue de la Chine, 75020 Paris (France)

    2013-11-01

    Background: Multidetector CT-angiography (MDCTA) is commonly used in patients with severe haemoptysis requiring admission to intensive care unit. However, the impact of MDCTA on the management of severe haemoptysis in emergency setting is poorly evaluated. Methods: We prospectively compared data provided by clinical bedside evaluation (clinical examination, chest-X-ray and fiberoptic bronchoscopy) to MDCTA data in terms of lateralization, location of the bleeding site, etiology as well as impact on the treatment choice. Results: Over a 13-month period, 87 patients (men n = 58, median age = 61 years, median haemoptysis expectorated volume = 180 mL) were included. Etiology was mainly (67%) bronchiectasis, tuberculosis sequelae and tumor. MDCTA and clinical bedside evaluation were equally effective in determining lateralization (87.4% and 93.1%, respectively, p = 0.23) and location (85% and 82.7%, respectively, p = 0.82) of the bleeding site. MDCTA was significantly more accurate than the clinical bedside strategy in determining the haemoptysis cause (86% and 70%, respectively, p = 0.007). Moreover, MDCTA suggested the involvement of systemic arteries as bleeding mechanism in 92% of cases, leading to the modification of the treatment initially considered after bedside evaluation in 21.8% of patients. Conclusion: MDCTA provides useful information for the management of patients with severe haemoptysis, especially in the treatment choice. Thus, in the absence of emergency fiberoptic bronchoscopy (FOB) requirement for airways management, MDCTA should be the first-line procedure performed in emergency clinical setting.

  1. Comparison of 16-row multislice CT angiography with conventional angiography for detection and evaluation of intracranial aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Donmez, Halil; Serifov, Elman; Kahriman, Guven [University of Erciyes, School of Medicine, Department of Radiology, Kayseri (Turkey); Mavili, Ertugrul, E-mail: ertmavili@yahoo.com [University of Erciyes, School of Medicine, Department of Radiology, Kayseri (Turkey); Durak, Ahmet Candan [University of Erciyes, School of Medicine, Department of Radiology, Kayseri (Turkey); Menkue, Ahmet [University of Erciyes, School of Medicine, Department of Neurosurgery, Kayseri (Turkey)

    2011-11-15

    Purpose: The aim of this study is to compare the diagnostic performance of 16-row computed tomographic angiography (MDCTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms in patients with nontraumatic subarachnoid hemorrhages (SAH). Materials and methods: One-hundred and twelve consecutive patients with suspected intracranial aneurysm underwent both 16-row MDCTA and DSA. The MDCT angiograms were interpreted in a blinded fashion by using combination with VRI, MIP and MPR techniques. Sensitivity specificity and accuracy were calculated for the CTA and DSA. The results were compared with each other. The DSA reader's interpretation was accepted as the reference standard. Results: A total of 164 aneurysms were detected at DSA in 112 patients, no aneurysms were detected by DSA and MDCTA in 16 patients. Eight aneurysms were missed by MDCTA. The overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 95.1%, 94.1%, and 95%, respectively. According to the size of the aneurysm less than 3 mm; sensitivity, specificity and diagnostic accuracy of MDCTA were 86.1%, 94.1%, 88.6%, respectively. Conclusion: This study suggests that MDCTA is equally as sensitive as DSA in the detection of intracranial aneurysms of greater than 3 mm, and it also reveals 100% detection rate for ruptured aneurysms.

  2. Magnetic resonance angiography and CT angiography of persistent primitive olfactory artery: Incidence and association rate with aneurysm in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Bo Ra; Yeo, Soo Hyun; Chang, Hyuk Won; Kim, Mi Jeong; Lee, Sung Moon; Kim, Ealmaan; Kim, Mi Kyung; Cho, Ho Chan; Kim, Hye Soon [Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2012-06-15

    Japanese data indicates an incidence of persistent primitive olfactory artery (PPOA) of 0.14%. We studied the incidence of PPOA and associated cerebral vascular variation or anomalies in Korea. We retrospectively reviewed cranial magnetic resonance angiography (MRA) and computed tomography angiography (CTA) images of a total of 9841 patients of our institution. The diagnostic criterion of PPOA is extreme anterioinferior course of the proximal anterior cerebral artery, with a hairpin turn of the lateral projection. We found 29 cases (0.29%) with PPOA. The PPOA location was on the left in 19 cases, bilateral in 3 cases, and on the right in 7 cases. An aneurysm was found at the hairpin turn in 2 patients. There were aneurysms in other sites in 3 cases. There were hypoplasia of anterior cerebral artery in 3 cases, and fenestration of intracranial artery in 1 case. In Korean populations, the incidence of PPOA found in MRA and CTA was twice as high as that shown in the previous Japanese data. Within Korea, left side laterality is more common than right side or bilalterality. Aneurysmal dilatations at the hairpin turning point and aneurysms at other sites were found, and other vascular variations were observed in several cases.

  3. Myocardial perfusion imaging with dual energy CT.

    Science.gov (United States)

    Jin, Kwang Nam; De Cecco, Carlo N; Caruso, Damiano; Tesche, Christian; Spandorfer, Adam; Varga-Szemes, Akos; Schoepf, U Joseph

    2016-10-01

    Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  4. Assessment of coronary artery disease using coronary computed tomography angiography and biochemical markers

    Institute of Scientific and Technical Information of China (English)

    Gitsios; Gitsioudis; Hugo; A; Katus; Grigorios; Korosoglou

    2014-01-01

    Chronic inflammatory mechanisms in the arterial wall lead to atherosclerosis,and include endothelial cell damage,inflammation,apoptosis,lipoprotein deposition,calcification and fibrosis.Cardiac computed tomography angiography(CCTA)has been shown to be a promising tool for non-invasive assessment of theses specific compositional and structural changes in coronary arteries.This review focuses on the technical background of CCTA-based quantitative plaque characterization.Furthermore,we discuss the available evidence for CCTA-based plaque characterization and the potential role of CCTA for risk stratification of patients with coronary artery disease.

  5. Data of evolutionary structure change: 1CCTA-3FE4B [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available A 1CCTA LSVSY--DQATS ...dbChain>A 1CCTA LPESL-DYWTY 3FE4 A B WGYGKHNGPEHWHKDFPIAKGERQSPVDIDTHTAKYDPS...YPGQRTTLTGLDVQDMLPRNLQHYYTYHGSLTTPPCTENVHWFVLADFVKLSRTQVWKLENSLLDH----RNKTIHNDYRRTQPLNHRVVESNFPN 0 1CCT

  6. Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography. Validation of a new fusion and visualisation software

    Energy Technology Data Exchange (ETDEWEB)

    Fricke, Harald; Weise, Reiner; Burchert, Wolfgang; Fricke, Eva [Inst. of Radiology, Nuclear Medicine and Molecular Imaging, Heart and Diabetes Centre North Rhine-Westphalia, Ruhr-Univ. Bochum, Bad Oeynhausen (Germany); Elsner, Andreas; Bolte, Matthias; Domik, Gitta [Research Group Computergraphics, Visualization and Image Processing, Univ. of Paderborn (Germany); Hoff, Joerg van den [PET Center, Inst. of Radiopharmacy, Research Center Rossendorf, Dresden (Germany)

    2009-07-01

    Aim: Dynamic perfusion PET offers a clinical relevant advantage over myocardial perfusion scintigraphy due to its ability to measure myocardial blood flow quantitatively. This leads to an improved detection of multivessel disease and the possibility to assess not only the culprit lesion but lower grade stenoses as well. For appropriate revascularization, perfusion defects must be matched to coronary lesions. It has been shown that image fusion of morphological and functional images is superior to side-by-side analysis. Still, software for quantitative perfusion PET combined with CT angiography is rare. In this paper we present a new software tool for image fusion and visualization of quantitative perfusion PET and coronary morphology derived from CT angiography. Methods: In our software, a PET uptake image is used for manual co-registration. Co-registration results are then applied to the functional data derived from compartment modelling. To evaluate the reproducibility of the manual co-registration, we calculated the deviation between a series of manual co-registrations performed on nine pairs of unregistered PET and CT datasets by five trained participants. Two dimensional transfer functions were used to highlight the coronary arteries from the CT study in the combined data sets. Results: The average Euclidian distances for three references points were between 3.7 and 4.1 mm. The maximum distance was 10.6 mm. By the use of the two dimensional transfer functions, coronary anatomy could be easily visualised either by user-interaction or automatically by use of neuronal networks. Conclusions: With this approach it is possible to combine quantitative perfusion PET with coronary anatomy derived from CT angiography. Our first experiences indicate that manual image fusion with our tool is reproducible and that visualisation of the combined datasets is achieved within short time. (orig.)

  7. Coronary artery abnormalities in Kawasaki disease - Comparison between CT and MR coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Woo; Goo, Hyun Woo [Dept. of Radiology and Research Inst. of Radiology, Univ. of Ulsan Coll. of Medicine, Asan Medical Center, Seoul (Korea, Republic of)], e-mail: hwoogoo@amc.seoul.kr

    2013-03-15

    Background: Although CT coronary angiography (CTCA) and MR coronary angiography (MRCA) are increasingly used in patients with Kawasaki disease, comparison of coronary artery assessability and diagnostic performance between the two imaging modalities has been rarely performed. Purpose: To investigate which imaging modality, CTCA or MRCA, is better for evaluating coronary artery abnormalities in patients with Kawasaki disease. Material and Methods: Between 2003 and 2011, 56 patients (38 boys/men; age range, 1-24 years) with Kawasaki disease underwent CTCA or MRCA (group A). Of these, 17 underwent both CTCA and MRCA (group B). Visibility of 11 coronary arterial segments in each patient was graded on a four-point scale. Coronary artery aneurysm, stenosis, and occlusion were evaluated by CTCA and MRCA, based on a reference standard obtained from cardiac catheterization, echocardiography, follow-up CTCA and MRCA, and clinical history. Coronary artery assessability and diagnostic performance were compared between CTCA and MRCA. Results: In per-segment analysis, more segments were assessable on CTCA than on MRCA in both groups. In per-patient analysis of group B, no significant difference in the assessability was found between CTCA (95.0%, 128.3/135 segments) and MRCA (92.4%, 124.8/135 segments) (P > 0.05). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CTCA vs. MRCA were 93.1% vs. 77.9% (P < 0.001), 99.2% vs. 99.7% (P = 0.65), 96.8% vs. 98.7% (P = 0.65), 98.2% vs. 94.1% (P < 0.001), and 98.0% vs. 94.9% (P = 0.008), respectively, in group A, and 91.8% vs. 70.4% (P < 0.001), 99.5% vs. 99.5% (P = 1.000), 98.5% vs. 98.0% (P = 1.000), 97.2% vs. 91.1% (P = 0.006), and 97.6% vs. 92.3% (P = 0.004), respectively, in group B. Conclusion: Although CTCA and MRCA show comparable assessability in per-patient analysis, CTCA shows higher diagnostic performance than MRCA for evaluating coronary artery abnormalities in patients with Kawasaki

  8. Rotational micro-CT using a clinical C-arm angiography gantry

    Energy Technology Data Exchange (ETDEWEB)

    Patel, V.; Hoffmann, K. R.; Ionita, C. N.; Keleshis, C.; Bednarek, D. R.; Rudin, S. [Toshiba Stroke Research Center, Department of Physics, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Neurosurgery, Department of Physics, Department of Physiology and Biophysics, Department of Mechanical and Aerospace Engineering, and Department of Computer Science, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Radiology, Department of Neurosurgery, Department of Physics, and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Toshiba Stroke Research Center, Department of Radiology, Department of Neurosurgery, Department of Physiology and Biophysics, Department of Mechanical and Aerospace Engineering, and Department of Electrical Engineering, State University of New York at Buffalo, Buffalo, New York 14214 (United States)

    2008-10-15

    Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution (<4 lp/mm). Micro-computed tomography (micro-CT) systems have better resolution (>10 lp/mm) but to date have relied either on rotating object imaging or small bore geometry for small animal imaging, and thus are not used for clinical imaging. The authors report here the development and use of a 3D rotational micro-angiography (RMA) system created by mounting a micro-angiographic fluoroscope (MAF) [35 {mu}m pixel, resolution >10 lp/mm, field of view (FOV)=3.6 cm] on a standard clinical FPD-based RA gantry (Infinix, Model RTP12303J-G9E, Toshiba Medical Systems Corp., Tustin, CA). RA image sequences are obtained using the MAF and reconstructed. To eliminate artifacts due to image truncation, lower-dose (compared to MAF acquisition) full-FOV (FFOV) FPD RA sequences (194 {mu}m pixel, FOV=20 cm) were also obtained to complete the missing data. The RA gantry was calibrated using a helical bead phantom. To ensure high-quality high-resolution reconstruction, the high-resolution images from the MAF were aligned spatially with the lower-dose FPD images, and the pixel values in the FPD image data were scaled to match those of the MAF. Images of a rabbit with a coronary stent placed in an artery in the Circle of Willis were obtained and reconstructed. The MAF images appear well aligned with the FPD images (average correlation coefficient before and after alignment: 0.65 and 0.97, respectively) Greater details without any visible truncation artifacts are seen in 3D RMA (MAF-FPD) images than in those of the FPD alone. The FWHM of line profiles of stent struts (100 {mu}m diameter) are approximately 192{+-}21 and 313{+-}38 {mu}m for the 3D RMA and FPD data, respectively. In addition, for the dual-acquisition 3D RMA

  9. Is metabolic syndrome predictive of prevalence, extent, and risk of coronary artery disease beyond its components? Results from the multinational coronary CT angiography evaluation for clinical outcome: an international multicenter registry (CONFIRM.

    Directory of Open Access Journals (Sweden)

    Amir Ahmadi

    Full Text Available Although metabolic syndrome is associated with increased risk of cardiovascular disease and events, its added prognostic value beyond its components remains unknown. This study compared the prevalence, severity of coronary artery disease (CAD, and prognosis of patients with metabolic syndrome to those with individual metabolic syndrome components. The study cohort consisted of 27125 consecutive individuals who underwent ≥ 64-detector row coronary CT angiography (CCTA at 12 centers from 2003 to 2009. Metabolic syndrome was defined as per NCEP/ATP III criteria. Metabolic syndrome patients (n = 690 were matched 1:1:1 to those with 1 component (n = 690 and 2 components (n = 690 of metabolic syndrome for age, sex, smoking status, and family history of premature CAD using propensity scoring. Major adverse cardiac events (MACE were defined by a composite of myocardial infarction (MI, acute coronary syndrome, mortality and late target vessel revascularization. Patients with 1 component of metabolic syndrome manifested lower rates of obstructive 1-, 2-, and 3-vessel/left main disease compared to metabolic syndrome patients (9.4% vs 13.8%, 2.6% vs 4.5%, and 1.0% vs 2.3%, respectively; p 0.05. At 2.5 years, metabolic syndrome patients experienced a higher rate of MACE compared to patients with 1 component (4.4% vs 1.6%; p = 0.002, while no difference observed compared to individuals with 2 components (4.4% vs 3.2% p = 0.25 of metabolic syndrome. In conclusion, Metabolic syndrome patients have significantly greater prevalence, severity, and prognosis of CAD compared to patients with 1 but not 2 components of metabolic syndrome.

  10. Is Metabolic Syndrome Predictive of Prevalence, Extent, and Risk of Coronary Artery Disease beyond Its Components? Results from the Multinational Coronary CT Angiography Evaluation for Clinical Outcome: An International Multicenter Registry (CONFIRM)

    Science.gov (United States)

    Ahmadi, Amir; Leipsic, Jonathon; Feuchtner, Gudrun; Gransar, Heidi; Kalra, Dan; Heo, Ran; Achenbach, Stephan; Andreini, Daniele; Al-Mallah, Mouaz; Berman, Daniel S.; Budoff, Matthew; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Chinnaiyan, Kavitha; Chow, Benjamin; Cury, Ricardo C.; Delago, Augustin; Gomez, Millie J.; Hadamitzky, Martin; Hausleiter, Joerg; Hindoyan, Niree; Kaufmann, Philipp A.; Kim, Yong-Jin; Lin, Fay; Maffei, Erica; Pontone, Gianluca; Raff, Gilbert L.; Shaw, Leslee J.; Villines, Todd C.; Dunning, Allison; Min, James K.

    2015-01-01

    Although metabolic syndrome is associated with increased risk of cardiovascular disease and events, its added prognostic value beyond its components remains unknown. This study compared the prevalence, severity of coronary artery disease (CAD), and prognosis of patients with metabolic syndrome to those with individual metabolic syndrome components. The study cohort consisted of 27125 consecutive individuals who underwent ≥64-detector row coronary CT angiography (CCTA) at 12 centers from 2003 to 2009. Metabolic syndrome was defined as per NCEP/ATP III criteria. Metabolic syndrome patients (n=690) were matched 1:1:1 to those with 1 component (n=690) and 2 components (n=690) of metabolic syndrome for age, sex, smoking status, and family history of premature CAD using propensity scoring. Major adverse cardiac events (MACE) were defined by a composite of myocardial infarction (MI), acute coronary syndrome, mortality and late target vessel revascularization. Patients with 1 component of metabolic syndrome manifested lower rates of obstructive 1-, 2-, and 3-vessel/left main disease compared to metabolic syndrome patients (9.4% vs 13.8%, 2.6% vs 4.5%, and 1.0% vs 2.3%, respectively; p0.05). At 2.5 years, metabolic syndrome patients experienced a higher rate of MACE compared to patients with 1 component (4.4% vs 1.6%; p=0.002), while no difference observed compared to individuals with 2 components (4.4% vs 3.2% p=0.25) of metabolic syndrome. In conclusion, Metabolic syndrome patients have significantly greater prevalence, severity, and prognosis of CAD compared to patients with 1 but not 2 components of metabolic syndrome. PMID:25734639

  11. 64-slice coronary computed tomography angiography using low tube voltage of 80 kV in subjects with normal body mass indices: comparative study using 120 kV

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Bo Ram; Yong, Hwan Seok; Kang, Eun-Young; Woo, Ok Hee; Choi, Eun Jung [Department of Radiology, Korea University Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)], E-mail: yhwanseok@naver.com

    2012-12-15

    Background. The radiation dose of coronary computed tomography (CT) angiography (CCTA) is generally higher than that of CT scans of other parts of the body, and there is concern that the high radiation dose may result in increased cancer risk. Although various techniques have recently been introduced to lower the radiation dose of CCTA, there has been no direct comparison between protocols with 80 and 120 kV. Purpose. To assess the image quality and radiation dose of 80-kV electrocardiography (ECG)-gated CCTA in subjects with a normal body mass index (BMI), compared to 120-kV ECG-gated CCTA. Material and Methods. This retrospective study was approved by our local ethics board, and the requirement of written informed consent was waived. We analyzed the CCTA images of 100 subjects with BMIs <25 kg/m2. Fifty subjects underwent 120-kV CCTA, and the other 50 subjects underwent 80-kV CCTA. Two blinded observers independently evaluated the subjective image quality of the coronary arteries. The objective image quality (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and radiation dose were also measured in each group. Results. Although the objective image quality of the 80-kV protocol images was significantly poorer than that of 120-kV protocol images (mean SNR, 14.9 {+-} 4.7 vs. 19.8 {+-} 4.4, P < 0.0001; mean CNR, 15.2 {+-} 4.8 vs. 21.6 {+-} 4.7, P < 0.0001), there was no significant difference in the subjective image quality between the two groups (mean image score, 4.7 {+-} 1.1 vs. 4.5 {+-} 0.7 for radiologist 1, P 0.273; 5.0 {+-} 1.0 vs. 4.8 {+-} 1.0 for radiologist 2, P = 0.197). The radiation dose was reduced by 70% with the 80-kV protocol and by 88% with the 80-kV and ECG-based tube current modulation than with the 120-kV protocol (3.42 {+-} 1.16 and 2.9 {+-} 0.8 vs. 11.49 {+-} 3.62 mSv, P < 0.0001). Conclusion. The low tube voltage CCTA protocol using 80 kV allows significant reduction of the radiation dose without impairing the subjective image

  12. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ...

  13. Accuracy of automated software-guided detection of significant coronary artery stenosis by CT angiography: comparison with invasive catheterisation

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Katharina; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany); Achenbach, Stephan; Petit, Isabel; Daniel, Werner G.; Pflederer, Tobias [University of Erlangen, Department of Internal Medicine 2 (Cardiology), Erlangen (Germany)

    2013-05-15

    True automated detection of coronary artery stenoses might be useful whenever expert evaluation is not available, or as a ''second reader'' to enhance diagnostic confidence. We evaluated the accuracy of a PC-based stenosis detection tool alone and combined with expert interpretation. One hundred coronary CT angiography datasets were evaluated with the automated software alone, by manual interpretation (axial images, multiplanar reformations and maximum intensity projections in free double-oblique planes), and by expert interpretation aware of the automated findings. Stenoses {>=} 50 % were noted per-vessel and per-patient, and compared with invasive angiography. Automated post-processing was successful in 90 % of patients (88 % of vessels). When excluding uninterpretable datasets, per-patient sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 89 %, 79 %, 74 % and 92 % (per-vessel: 82 %, 85 %, 48 % and 96 %). All 100 datasets were evaluable by expert interpretation. Per-patient sensitivity, specificity, PPV and NPV were 95 %, 95 %, 93 % and 97 % (per-vessel: 89 %,98 %, 88 % and 98 %). Knowing the results of automated interpretation did not improve the performance of expert readers. Automated off-line post-processing of coronary CT angiography shows adequate sensitivity, but relatively low specificity in coronary stenosis detection. It does not increase accuracy of expert interpretation. Failure of post-processing in 10 % of all patients necessitates additional manual image work-up. (orig.)

  14. Pulmonary CT angiography protocol adapted to the hemodynamic effects of pregnancy.

    LENUS (Irish Health Repository)

    Ridge, Carole A

    2012-02-01

    OBJECTIVE: The purpose of this study was to compare the image quality of a standard pulmonary CT angiography (CTA) protocol with a pulmonary CTA protocol optimized for use in pregnant patients with suspected pulmonary embolism (PE). MATERIALS AND METHODS: Forty-five consecutive pregnant patients with suspected PE were retrospectively included in the study: 25 patients (group A) underwent standard-protocol pulmonary CTA and 20 patients (group B) were imaged using a protocol modified for pregnancy. The modified protocol used a shallow inspiration breath-hold and a high concentration, high rate of injection, and high volume of contrast material. Objective image quality and subjective image quality were evaluated by measuring pulmonary arterial enhancement, determining whether there was transient interruption of the contrast bolus by unopacified blood from the inferior vena cava (IVC), and assessing diagnostic adequacy. RESULTS: Objective and subjective image quality were significantly better for group B-that is, for the group who underwent the CTA protocol optimized for pregnancy. Mean pulmonary arterial enhancement and the percentage of studies characterized as adequate for diagnosis were higher in group B than in group A: 321 +\\/- 148 HU (SD) versus 178 +\\/- 67 HU (p = 0.0001) and 90% versus 64% (p = 0.05), respectively. Transient interruption of contrast material by unopacified blood from the IVC was observed more frequently in group A (39%) than in group B (10%) (p = 0.05). CONCLUSION: A pulmonary CTA protocol optimized for pregnancy significantly improved image quality by increasing pulmonary arterial opacification, improving diagnostic adequacy, and decreasing transient interruption of the contrast bolus by unopacified blood from the IVC.

  15. Pulmonary embolism in pregnancy: comparison of pulmonary CT angiography and lung scintigraphy.

    LENUS (Irish Health Repository)

    Ridge, Carole A

    2012-02-01

    OBJECTIVE: The purpose of this study was to retrospectively compare the diagnostic adequacy of lung scintigraphy with that of pulmonary CT angiography (CTA) in the care of pregnant patients with suspected pulmonary embolism. MATERIALS AND METHODS: Patient characteristics, radiology report content, additional imaging performed, final diagnosis, and diagnostic adequacy were recorded for pregnant patients consecutively referred for lung scintigraphy or pulmonary CTA according to physician preference. Measurements of pulmonary arterial enhancement were performed on all pulmonary CTA images of pregnant patients. Lung scintigraphy and pulmonary CTA studies deemed inadequate for diagnosis at the time of image acquisition were further assessed, and the cause of diagnostic inadequacy was determined. The relative contribution of the inferior vena cava to the right side of the heart was measured on nondiagnostic CTA images and compared with that on CTA images of age-matched nonpregnant women, who were the controls. RESULTS: Twenty-eight pulmonary CTA examinations were performed on 25 pregnant patients, and 25 lung scintigraphic studies were performed on 25 pregnant patients. Lung scintigraphy was more frequently adequate for diagnosis than was pulmonary CTA (4% vs 35.7%) (p = 0.0058). Pulmonary CTA had a higher diagnostic inadequacy rate among pregnant than nonpregnant women (35.7% vs 2.1%) (p < 0.001). Transient interruption of contrast material by unopacified blood from the inferior vena cava was identified in eight of 10 nondiagnostic pulmonary CTA studies. CONCLUSION: We found that lung scintigraphy was more reliable than pulmonary CTA in pregnant patients. Transient interruption of contrast material by unopacified blood from the inferior vena cava is a common finding at pulmonary CTA of pregnant patients.

  16. Value of CT angiography in anterior circulation large vessel occlusive stroke: Imaging findings, pearls, and pitfalls

    Energy Technology Data Exchange (ETDEWEB)

    Power, Sarah, E-mail: drsarahpower@gmail.com [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); McEvoy, Sinead H., E-mail: sineadmcevoy@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Cunningham, Jane, E-mail: janecunningham0708@gmail.com [Department of Radiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Ti, Joanna P., E-mail: joannapearlyti@gmail.com [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Looby, Seamus, E-mail: seamuslooby@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); O' Hare, Alan, E-mail: alanohare@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Williams, David, E-mail: davidwilliams@rcsi.ie [Department of Geriatrics and Stroke Medicine, Royal College of Surgeons in Ireland (RCSI) and Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Brennan, Paul, E-mail: paulbrennan@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland); Thornton, John, E-mail: johnthornton@beaumont.ie [Department of Neuroradiology, Beaumont Hospital, P.O. Box 1297, Beaumont Rd, Dublin 9 (Ireland)

    2015-07-15

    Highlights: • Site of occlusion determines potential collateralization routes and impacts outcome. • Multifocality of arterial occlusion is common, seen in approximately 20% of cases. • ICA false occlusion sign can be seen in setting of ICA stenosis or carotid T occlusion. • False patency sign: hyperdense thrombus/calcified occlusive plaque misinterpreted as patent vessel. • Additional abnormalities on CTA may infer stroke mechanism or alter decision making. - Abstract: Hyperacute stroke imaging is playing an increasingly important role in determining management decisions in acute stroke patients, particularly patients with large vessel occlusive stroke who may benefit from endovascular intervention. CT angiography (CTA) is an important tool in the work-up of the acute stroke patient. It reliably detects large occlusive thrombi in proximal cerebral arteries and is a quick and highly accurate method in identifying candidates for endovascular stroke treatment. In this article we review the imaging findings on CTA in acute large vessel occlusive stroke using a pictorial case based approach. We retrospectively reviewed CTA studies in 48 patients presenting with acute anterior circulation large vessel occlusive stroke who were brought for intra-arterial acute stroke intervention. We discuss and illustrate patterns of proximal intracranial arterial occlusion, collateralization to the occluded territory, as well as reviewing some important pearls, pitfalls and teaching points in CTA assessment of the acute stroke patient. Performed from the level of the aortic arch CTA also gives valuable information regarding the state of other vessels in the acute stroke patient, identifying additional significant vascular stenoses or occlusions, and as we illustrate, can demonstrate other clinically significant findings which may impact on patient management and outcome.

  17. Three-dimensional CT angiography study on the relations between the vertebral artery and atlantoaxial joint

    Institute of Scientific and Technical Information of China (English)

    DUAN Shao-yin; LU Shao-mao; YE Feng; LIN Qing-chi; CHEN Liao-bin

    2009-01-01

    Background The vertebral artery (VA) and atlantoaxial joint (AAJ), with complicated structures, are located in the depths of the head-neck boundary area, the regional anatomy of which cannot be shown globally and directly. This study aims to evaluate three-dimensional CT angiography (3DCTA) in displaying the AAJ, atlantoaxial segment of the vertebral artery (ASVA) and the identification of their interrelations.Methods Sixty-eight subjects without pathology of the ASVA and AAJ were selected from head-neck CTA examination. All the 3D images were formed with volume rendering (VR) together with techniques of separating, fusing, opacifying and false-coloring (SFOF). On the 3D images, the ASVA and AAJ were observed, and their interrelations were measured.Results All the 3DCTA images were of high quality and up to our requirements. They could cleady and directly show the ASVA, ascending along the AAJ. There were 5 curves in the course of the ASVA, of which 2 curves were away from the atlantoaxial joint, one in the 2nd curve of 0.0 mm-5.4 mm, the other in the 4th of 2.6 mm-9.2 mm. There was no significant difference in the measurements between left and dght (P>0.05). The curved parts of the ASVA slightly expanded, with the biggest diameter of 5.6 mm in the 4th curve. Statistical comparison shows that the left ASVA is larger than the right (P<0.05). Variations of the ASVA were found in 8 cases and of the AAJ in 12.Conclusions 3DCTA can globally and directly demonstrate the structures of the AAJ, ASVA and their interrelations. The 3D imaging data make up and enrich the research contents of regional anatomy and lay the foundation for related study and applications.

  18. Alternative diagnoses based on CT angiography of the chest in patients with suspected pulmonary thromboembolism

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Eleci Vaz; Gazzana, Marcelo Basso; Seligman, Renato; Knorst, Marli Maria, E-mail: mknorst@gmail.com [Hospital de Clinicas de Porto Alegre, Porto Alegre, RS (Brazil); Guerra, Vinicius Andre [Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre, RS (Brazil). Faculdade de Medicina. Programa de Pos-Graduacao em Ciencias Pneumologicas; Sarmento, Muriel Bossle; Guazzelli, Pedro Arends; Hoffmeister, Mariana Costa [Universidade Federal do Rio Grande do Sul (UFRS), Porto Alegre (Brazil). Faculdade de Medicina

    2016-01-15

    Objective: To determine the prevalence of alternative diagnoses based on chest CT angiography (CTA) in patients with suspected pulmonary thromboembolism (PTE) who tested negative for PTE, as well as whether those alternative diagnoses had been considered prior to the CTA. Methods: This was a cross-sectional, retrospective study involving 191 adult patients undergoing CTA for suspected PTE between September of 2009 and May of 2012. Chest X-rays and CTAs were reviewed to determine whether the findings suggested an alternative diagnosis in the cases not diagnosed as PTE. Data on symptoms, risk factors, comorbidities, length of hospital stay, and mortality were collected. Results: On the basis of the CTA findings, PTE was diagnosed in 47 cases (24.6%). Among the 144 patients not diagnosed with PTE via CTA, the findings were abnormal in 120 (83.3%). Such findings were consistent with an alternative diagnosis that explained the symptoms in 75 patients (39.3%). Among those 75 cases, there were only 39 (20.4%) in which the same alterations had not been previously detected on chest X-rays. The most common alternative diagnosis, made solely on the basis of the CTA findings, was pneumonia (identified in 20 cases). Symptoms, risk factors, comorbidities, and the in-hospital mortality rate did not differ significantly between the patients with and without PTE. However, the median hospital stay was significantly longer in the patients with PTE than in those without (18.0 and 9.5 days, respectively; p = 0.001). Conclusions: Our results indicate that chest CTA is useful in cases of suspected PTE, because it can confirm the diagnosis and reveal findings consistent with an alternative diagnosis in a significant number of patients. (author)

  19. CT angiography spot sign in intracerebral hemorrhage predicts active bleeding during surgery.

    Science.gov (United States)

    Brouwers, H Bart; Raffeld, Miriam R; van Nieuwenhuizen, Koen M; Falcone, Guido J; Ayres, Alison M; McNamara, Kristen A; Schwab, Kristin; Romero, Javier M; Velthuis, Birgitta K; Viswanathan, Anand; Greenberg, Steven M; Ogilvy, Christopher S; van der Zwan, Albert; Rinkel, Gabriel J E; Goldstein, Joshua N; Klijn, Catharina J M; Rosand, Jonathan

    2014-09-02

    To determine whether the CT angiography (CTA) spot sign marks bleeding complications during and after surgery for spontaneous intracerebral hemorrhage (ICH). In a 2-center study of consecutive spontaneous ICH patients who underwent CTA followed by surgical hematoma evacuation, 2 experienced readers (blinded to clinical and surgical data) reviewed CTAs for spot sign presence. Blinded raters assessed active intraoperative and postoperative bleeding. The association between spot sign and active intraoperative bleeding, postoperative rebleeding, and residual ICH volumes was evaluated using univariable and multivariable logistic regression. A total of 95 patients met inclusion criteria: 44 lobar, 17 deep, 33 cerebellar, and 1 brainstem ICH; ≥1 spot sign was identified in 32 patients (34%). The spot sign was the only independent marker of active bleeding during surgery (odds ratio [OR] 3.4; 95% confidence interval [CI] 1.3-9.0). Spot sign (OR 4.1; 95% CI 1.1-17), female sex (OR 6.9; 95% CI 1.7-37), and antiplatelet use (OR 4.6; 95% CI 1.2-21) were predictive of postoperative rebleeding. Larger residual hematomas and postoperative rebleeding were associated with higher discharge case fatality (OR 3.4; 95% CI 1.1-11) and a trend toward increased case fatality at 3 months (OR 2.9; 95% CI 0.9-8.8). The CTA spot sign is associated with more intraoperative bleeding, more postoperative rebleeding, and larger residual ICH volumes in patients undergoing hematoma evacuation for spontaneous ICH. The spot sign may therefore be useful to select patients for future surgical trials. © 2014 American Academy of Neurology.

  20. Alternative diagnoses based on CT angiography of the chest in patients with suspected pulmonary thromboembolism

    Science.gov (United States)

    Ferreira, Eleci Vaz; Gazzana, Marcelo Basso; Sarmento, Muriel Bossle; Guazzelli, Pedro Arends; Hoffmeister, Mariana Costa; Guerra, Vinicius André; Seligman, Renato; Knorst, Marli Maria

    2016-01-01

    Objective : To determine the prevalence of alternative diagnoses based on chest CT angiography (CTA) in patients with suspected pulmonary thromboembolism (PTE) who tested negative for PTE, as well as whether those alternative diagnoses had been considered prior to the CTA. Methods : This was a cross-sectional, retrospective study involving 191 adult patients undergoing CTA for suspected PTE between September of 2009 and May of 2012. Chest X-rays and CTAs were reviewed to determine whether the findings suggested an alternative diagnosis in the cases not diagnosed as PTE. Data on symptoms, risk factors, comorbidities, length of hospital stay, and mortality were collected. Results : On the basis of the CTA findings, PTE was diagnosed in 47 cases (24.6%). Among the 144 patients not diagnosed with PTE via CTA, the findings were abnormal in 120 (83.3%). Such findings were consistent with an alternative diagnosis that explained the symptoms in 75 patients (39.3%). Among those 75 cases, there were only 39 (20.4%) in which the same alterations had not been previously detected on chest X-rays. The most common alternative diagnosis, made solely on the basis of the CTA findings, was pneumonia (identified in 20 cases). Symptoms, risk factors, comorbidities, and the in-hospital mortality rate did not differ significantly between the patients with and without PTE. However, the median hospital stay was significantly longer in the patients with PTE than in those without (18.0 and 9.5 days, respectively; p = 0.001). Conclusions : Our results indicate that chest CTA is useful in cases of suspected PTE, because it can confirm the diagnosis and reveal findings consistent with an alternative diagnosis in a significant number of patients. PMID:26982039

  1. Duplex ultrasonography for the detection of vertebral artery stenosis: A comparison with CT angiography.

    Science.gov (United States)

    Rozeman, Anouk D; Hund, Hajo; Westein, Michel; Wermer, Marieke J H; Lycklama À Nijeholt, Geert J; Boiten, Jelis; Schimsheimer, Robert-Jan; Algra, Ale

    2017-08-01

    Vertebrobasilar stenosis is frequent in patients with posterior circulation stroke and it increases risk of recurrence. We investigated feasibility of duplex ultrasonography (DUS) for screening for extracranial vertebral artery stenosis and compared it with CT angiography (CTA). We gathered data on 337 consecutive patients who had DUS because of posterior circulation stroke or TIA. Matching CTA studies were retrieved and used as reference. Stenosis on CTA was considered "significant" if >50%, at DUS if Peak Systolic Velocity (PSV) > 140 cm/s for the V1 segment and PSV > 125 cm/s for the V2 segment. We determined the area under the ROC curve (AUROC). In addition, we calculated which PSV cut-off value resulted in highest sensitivity with acceptable specificity. DUS was able to make an adequate measurement in 378 of 674 V1 segments and 673 of 674 V2 segments. DUS detected a significant stenosis in 52 of 378 V1 segments; 12 were confirmed by CTA (AUROC 0.73, 95% Confidence Interval 0.63-0.83). The optimal DUS PSV cut-off value for this segment was 90 cm/s. For the V2 segment there were too few stenoses to allow reliable assessment of diagnostic characteristics of DUS. Although DUS has a fair AUROC for detecting significant stenosis, adequate assessment of the V1 segment is often not possible due to anatomic difficulties. Assessment of the V2 segment is feasible but yielded few stenoses. Hence, we consider usefulness of DUS for screening of extracranial vertebral artery stenosis limited.

  2. Alternative diagnoses based on CT angiography of the chest in patients with suspected pulmonary thromboembolism

    Directory of Open Access Journals (Sweden)

    Eleci Vaz Ferreira

    2016-02-01

    Full Text Available Objective : To determine the prevalence of alternative diagnoses based on chest CT angiography (CTA in patients with suspected pulmonary thromboembolism (PTE who tested negative for PTE, as well as whether those alternative diagnoses had been considered prior to the CTA. Methods : This was a cross-sectional, retrospective study involving 191 adult patients undergoing CTA for suspected PTE between September of 2009 and May of 2012. Chest X-rays and CTAs were reviewed to determine whether the findings suggested an alternative diagnosis in the cases not diagnosed as PTE. Data on symptoms, risk factors, comorbidities, length of hospital stay, and mortality were collected. Results : On the basis of the CTA findings, PTE was diagnosed in 47 cases (24.6%. Among the 144 patients not diagnosed with PTE via CTA, the findings were abnormal in 120 (83.3%. Such findings were consistent with an alternative diagnosis that explained the symptoms in 75 patients (39.3%. Among those 75 cases, there were only 39 (20.4% in which the same alterations had not been previously detected on chest X-rays. The most common alternative diagnosis, made solely on the basis of the CTA findings, was pneumonia (identified in 20 cases. Symptoms, risk factors, comorbidities, and the in-hospital mortality rate did not differ significantly between the patients with and without PTE. However, the median hospital stay was significantly longer in the patients with PTE than in those without (18.0 and 9.5 days, respectively; p = 0.001. Conclusions : Our results indicate that chest CTA is useful in cases of suspected PTE, because it can confirm the diagnosis and reveal findings consistent with an alternative diagnosis in a significant number of patients.

  3. [The Difference of CT Value Related to Monitor Position in the Head CT-angiography Bolus Tracking Method for Patients with Subarachnoid Hemorrhage].

    Science.gov (United States)

    Mizui, Masato; Mizoguchi, Yuji; Tashiro, Takao

    2016-01-01

    The head computed tomography-angiography (head CT-A) examination is excellent for the detection and diagnosis of cerebral artery aneurysm. If we use bolus tracking method when implementing this examination, we must choose a monitoring point. We investigated the influence which the monitoring point (MCA or carotid-A) exerts on the CT value. As for the result, MCA monitoring point method was more excellent than the carotid artery monitoring point method. The CT value was higher about 50 HU in the MCA monitoring point than in the carotid artery monitoring point (average;carotid artery: 349.6±57.8 HU, MCA: 413.2±67.9 HU). So, we conclude that in the bolus tracking method of monitoring point of head CTA, MCA monitoring point should be used.

  4. [A comparison of ventilation/perfusion single photon emission CT and CT pulmonary angiography for diagnosis of pulmonary embolism].

    Science.gov (United States)

    Meng, Jing-jing; Zhang, Li-jun; Wang, Qian; Fang, Wei; Dai, Hao-jie; Yan, Jue; Wang, Tie; Yao, Zhi-ming; He, Jia; Li, Mei; Mi, Hong-zhi; Jiao, Jian; Zheng, Yu-min

    2013-03-01

    To assess the diagnostic accuracy of ventilation/perfusion (V/Q) single photon emission CT (SPECT) as compared to computed tomographic pulmonary angiography (CTPA) for pulmonary embolism (PE). In this prospective multicenter study, 111 patients in whom acute or sub-acute PE was clinically confirmed or suspected were enrolled. The patients underwent one-day method V/Q lung scan (including SPECT and planar imaging) within 3 days before and after completion of CTPA. The European Association of Nuclear Medicine (EANM) guidelines for ventilation/perfusion scintigraphy (2009) reference was used as the evaluation criteria of V/Q SPECT imaging. The refined modified prospective investigation of pulmonary embolism diagnosis (RM-PIOPED) criteria was used for evaluation of planar imaging. According to the direct and indirect signs of PE, the imaging of CTPA was evaluated. All patients were followed for at least 6 months. A diagnosis was finally made by consensus of respiratory physicians, radiologists and nuclear medicine physicians based on the clinical data, laboratory tests, imaging features and follow-up results. The difference among diagnostic methods was evaluated for significance using chi-square test. The receiver operator characteristic (ROC) curve was drawn according to the results of the 3 diagnostic tests. The area under ROC curve (AUC) was calculated and compared. P < 0.05 was considered statistically significant. Among the 111 patients, PE was confirmed in 80, and excluded in 31. The diagnostic sensitivity/specificity/accuracy of V/Q SPECT, planar imaging, and CTPA were 85.9%/93.5%/88.1%, 75.7%/92.9%/81.4%, and 85.5%/90.0%/86.8%, respectively. By ROC curve analysis, the AUC values of V/Q SPECT, planar imaging and CTPA were 0.898, 0.838, and 0.877, respectively; with 95% confidence intervals [CI] 0.831 to 0.966, 0.759 to 0.917, and 0.801 to 0.954, respectively. The area of the fitted smooth ROC curve was statistically significant (P < 0.05) as compared with the

  5. Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: Observations in an ex vivo model

    NARCIS (Netherlands)

    L. la Grutta (Ludovico); M. Galia (Massimo); G. Gentile; G. Lo Re (G.); E. Grassedonio (Emanuele); F. Coppolino; E. Maffei (Erica); E. Maresi (E.); A. Lo Casto (A.); F. Cademartiri (Filippo); M. Midiri (Massimo)

    2013-01-01

    textabstractObjective: To compare the influence of different iodinated contrast media with several dilutions on plaque attenuation in an ex vivo coronary model studied by multislice CT coronary angiography. Methods: In six ex vivo left anterior descending coronary arteries immersed in oil, CT (slice

  6. Effects of Propranolol on the Left Ventricular Volume of Normal Subjects During CT Coronary Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Yuan Heng; Jaw, Fu Shan [National Taiwan University, Taipei, Taiwan (China); Wang, Yung Cheng; Jeng, Chin Ming [Fu Jen Catholic University, Taipei, Taiwan (China); Peng, Shinn Forng [National Taiwan University Hospital, Taipei, Taiwan (CN)

    2011-06-15

    The purpose of this study is to determine the effects of propranolol on the left ventricular (LV) volume during CT coronary angiography. The LV volume of 252 normal Chinese subjects (126 subjects with propranolol medication and 126 age- and gender-matched Chinese subjects without medication) was estimated using 64 slices multi-detector CT (MDCT). The heart rate difference was analyzed by the logistic linear regression model with variables that included gender, age, body height, body weight, systolic blood pressure (SBP), diastolic blood pressure (DBP) and the dosage of propranolol. The following global LV functional parameters were calculated: the real-end diastolic volume (EDV), the real-end systolic volume (ESV) and the real-ejection fraction (EF). The female subjects had a greater decrease of heart rate after taking propranolol. The difference of heart rate was negatively correlated with the dosage of propranolol. The real-EDV, the real-ESV and the real-EF ranged from 48.1 to 109 mL/m2, 6.1 to 57.1 mL/m2 and 41% to 88%, respectively. There was no significant difference in the SBP and DBP between the groups without and with propranolol medication (123 {+-} 17 and 80 {+-} 10 mmHg; 120 {+-} 14 and 80 {+-} 11 mmHg, respectively). The real-EDV showed no significant difference between these two groups, but the real-ESV and real-EF showed significant differences between these two groups (69.4 {+-} 9.3 and 70.6 {+-} 8.9 mL/m2; 23.5 {+-} 5.7 and 25.6 {+-} 3.7 mL/m2, 66.5 {+-} 5.1% and 63.5 {+-} 4.6%, respectively). The difference of heart rate is significantly influenced by gender and the dosage of propranolol. Propranolol will also increase the ESV, which contributes to a decreased EF, while the SBP, DBP and EDV are not statistically changed.

  7. CT血管造影图像后处理技术%Image Processing Technology of CT Angiography

    Institute of Scientific and Technical Information of China (English)

    安静

    2014-01-01

    This paper introduces the concepts and characteristics of various image processing technologies of CT angiography (CTA) including multiplanar reconstruction (MPR), minimum intensity projection (MinIP), volume rendering (VR), maximum intensity projection (MIP), virtual endoscopy (VE), Surface Shaded Displace (SSD). Then discusses the advantages of CTA by comparing CTA with digital subtraction angiography (DSA).%本文阐述了多层面重建法(MPR)、最小密度投影法(MinIP)、容积再现(VR)、最大密度投影(MIP)、仿真内窥镜法(VE)、表面遮盖法(SSD)等CT血管造影(CTA)方法的概念及技术特点,并通过与脑血管造影(DSA)检查进行比较,探讨了CTA的优势。

  8. Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yining [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@hotmail.com; Zhang Zhuhua [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@sina.com; Kong Lingyan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: klyan78@hotmail.com; Song Lan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: sallysonglan@sina.com; Merges, Reto D. [CT Research Collaboration, Siemens Ltd. (China)], E-mail: reto.merges@siemens.com; Chen Jiuhong [CT Research Collaboration, Siemens Ltd. (China)], E-mail: jiuhong.chen@siemens.com; Jin Zhengyu [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: jin_zhengyu@sina.com

    2008-12-15

    Objective: To evaluate the performance of dual-source computed tomography (DSCT) for the visualization of the coronary arteries in a population with atrial fibrillation (AF) compared to single-source CT (SSCT) and to explore the impact of patients' heart rate (HR) on image quality (IQ) and reconstruction timing. Methods: Thirty consecutive patients (11 male, 19 female; 69.0 {+-} 9.2 years old) with suspected coronary artery disease and permanent AF were examined on a DSCT scanner (120 kV, 400 mAs/rot, 0.33 s rotation time, 64 x 0.6 mm collimation, pitch 0.20-0.28, Siemens Somatom Definition). Patients were divided into two groups: low and medium HR group (HR {<=} 80 bpm, n = 14) and high HR group (HR > 80 bpm, n = 16). Five of the patients also underwent conventional coronary angiography (CAG). The raw data from both tube detector arrays were reconstructed as DSCT data using a routine algorithm (temporal resolution of 83 ms). The raw data from one tube detector array was reconstructed separately on the same system using a routine single source algorithm (temporal resolution of 83-165 ms) and defined as virtual SSCT data. Image quality was assessed using a four-point grading scale from excellent (1) to non-assessable (4). Results: IQ of the DSCT data was significantly better than that of the virtual SSCT data (mean score 1.33 {+-} 0.61 vs. 1.80 {+-} 1.02; Z = -8.755, P = 0.000). 98.6% of the segments shown in DSCT were diagnostic, compared with 89.9% of the segments in virtual SSCT, {chi}{sup 2} = 32.595, P = 0.000. In DSCT group, IQ of low HR group was also better than that of high HR group, although the difference was not as big (mean score 1.25 {+-} 0.52 vs. 1.38 {+-} 0.66; Z = -2.227, P = 0.026). The mean HR of low HR group and high HR group were 67.4 {+-} 8.5 beats per minute (bpm) and 94.2 {+-} 8.8 bpm (t = -8.499, P = 0.000). The range of the variation of HR was higher in high HR group than in low HR group (mean difference between maximum and minimum HR

  9. Meta-analysis: diagnostic accuracy of coronary CT angiography with prospective ECG gating based on step-and-shoot, Flash and volume modes for detection of coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Linfeng; Zhou, Tao; Zhang, Ruijie; Peng, Zhaohui; Ding, Juan; Wang, Sen; Li, Min; Sun, Gang [Jinan Military General Hospital, Department of Medical Imaging, Jinan, Shandong Province (China); Xu, Lin [Jinan Military General Hospital, Department of Medical Cardiology, Jinan, Shandong Province (China)

    2014-10-15

    To investigate the diagnostic performance of coronary computed tomographic angiography (CCTA) with prospective electrocardiograph (ECG) gating based on step-and-shoot (SAS), Flash and volume imaging modes. We searched the electronic databases PubMed for all published studies regarding CCTA. We used an exact binomial rendition of the bivariate mixed-effects regression model developed for synthesis of diagnostic data. A total of 21,852 segments, 4,851 vessels and 1,375 patients were identified using database searches. Patient-level pooled sensitivity was 0.99 (95 % confidence interval [CI], 0.98-1.00); specificity was 0.88 (CI, 0.85-0.91). The results showed that the sensitivity and specificity for detection of significant stenosis did not differ in the three protocols (P = 0.24). No heterogeneity was found at the patient level for sensitivity (Q = 26.23; P = 0.12; I {sup 2} = 27.56 % [CI, 0.00-67.02 %]) and specificity (Q = 19.54; P = 0.42; I {sup 2} = 2.78 % [CI, 0.00-66.26 %]). CCTA with prospective ECG gating has similar high diagnostic value to rule out CAD in all three presented modes. (orig.)

  10. Intraobserver and interobserver variability in CT angiography and MR angiography measurements of the size of cerebral aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hye Jeong [Hallym University College of Medicine, Department of Radiology, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of); Yoon, Dae Young; Lee, Hyung Jin [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Kim, Eun Soo [Hallym University College of Medicine, Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, Gyeonggi-do (Korea, Republic of); Jeon, Hong Jun; Lee, Jong Young; Cho, Byung-Moon [Hallym University College of Medicine, Department of Neurosurgery, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of)

    2017-05-15

    Accurate and reliable measurement of aneurysm size is important for treatment planning. The purpose of this study was to determine intraobserver and interobserver variability of CTA and MRA for measurement of the size of cerebral aneurysms. Thirty patients with 33 unruptured cerebral aneurysms (saccular, >3 mm in their maximal dimension, with no daughter sacs or lobulations) who underwent 256-row multislice CTA, 3-D TOF MRA at 3.0T, and 3D rotational angiography (3DRA) were retrospectively analyzed. Three independent observers measured the neck, height, and width of the aneurysms using the CTA and MRA images. Intraobserver and interobserver variability of CTA and MRA measurements was evaluated using the standardized difference and intraclass correlation coefficient, with 3DRA measurements as the reference standard. In addition, the mean values of the measurements using CTA and MRA were compared with those using 3DRA. The overall intraobserver and interobserver standardized differences in CTA/MRA were 12.83-15.92%/13.48-17.45% and 14.08-17.00%/12.08-17.67%, respectively. The overall intraobserver and interobserver intraclass correlation coefficients of CTA/MRA were 0.88-0.98/0.84-0.96 and 0.86-0.98/0.85-0.95, respectively. Compared to the height and width measurements, measurements of the neck dimensions showed higher intraobserver and interobserver variability. The sizes of the cerebral aneurysms measured by CTA and MRA were 1.13-9.26 and 5.20-9.67% larger than those measured by 3DRA, respectively; however, these differences were not statistically significant. There were no noticeable differences between intraobserver and interobserver variability for both CTA- and MRA-based measurements of the size of cerebral aneurysms. (orig.)

  11. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols

    Energy Technology Data Exchange (ETDEWEB)

    Neefjes, Lisan A.; Kate, Gert-Jan R. ten [Erasmus Medical Center, Department of Cardiology, Room Hs 207, P.O. Box 2040, Rotterdam (Netherlands); Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Interuniversity Cardiology Institute of the Netherlands, Utrecht (Netherlands); Rossi, Alexia; Nieman, Koen; Papadopoulou, Stella L.; Dharampal, Anoeshka S.; Dedic, Admir; Feyter, Pim J. de; Mollet, Nico R. [Erasmus Medical Center, Department of Cardiology, Room Hs 207, P.O. Box 2040, Rotterdam (Netherlands); Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Genders, Tessa S.S.; Hunink, M.G.M. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Erasmus Medical Center, Department of Epidemiology, Rotterdam (Netherlands); Schultz, Carl J. [Erasmus Medical Center, Department of Cardiology, Room Hs 207, P.O. Box 2040, Rotterdam (Netherlands); Weustink, Annick C.; Dijkshoorn, Marcel L.; Straten, Marcel van; Cademartiri, Filippo; Krestin, Gabriel P. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2013-03-15

    To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 {+-} 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 {+-} 0.60 vs. 3.82 {+-} 1.65 mSv, P < 0.001). In group B (228 patients, 132 men, mean heart rate 75 {+-} 11 bpm), per-segment sensitivity, specificity, PPV and NPV were comparable (94 %, 95 %, 67 %, 99 % vs. 92 %, 95 %, 66 %, 99 %, P > 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 {+-} 2.58 vs. 8.13 {+-} 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose. circle 128-slice dual-source CT coronary angiography offers several different acquisition protocols. (orig.)

  12. Studies on intracranial collateral circulation with multi-slice CT angiography in patients with symptomatic cerebral artery stenosis

    Directory of Open Access Journals (Sweden)

    Shu-qing ZHOU

    2011-06-01

    Full Text Available Objective To explore the features of intracranial collateral circulation in patients with symptomatic cerebral artery stenosis.Method Ninety-four patients with ischemic cerebrovascular disease admitted from Apr.2004 to Jun.2009 were involved in present study.All the patients were examined with cerebral multi-slice CT angiography,and the features of cerebral artery stenosis and intracranial collateral circulation were evaluated using maximum intensity projection(MIP and volume rendering(VR images of CT angiography.Result Of the 94 patients involved,48 were diagnosed as cerebral artery stenosis,including 29 cases of cerebral infarction,18 of transient ischemic attack(TIA and 1 of moyamoya disease(MMD.Among the 14 cases of severe cerebral artery stenosis or occlusion,cerebral infarction was found in 6 cases with lesser intracranial collateral vessels(including massive cerebral infarction in 4 cases and watershed infarction in 2 cases,and focal infarction of central semi-ovale in 1 case and TIA in 7 cases were found with abundant intracranial collateral vessels.Multiple lacunar infarction was found in 22 cases of mild or moderate cerebral artery stenosis,but there was no significant correlation between the stenosed arteries and infarction sites.Abundant intracranial collateral vessels were found in one patient with Moyamoya disease but no infarction was observed.Conclusions Intracranial collateral circulation plays an important role of compensation in patients with severe cerebral artery stenosis or occlusion.Cerebral angiography with multi-slice CT is of great significance in evaluation of cerebral artery stenosis and intracranial collateral circulation.

  13. Quantification of Intracranial Aneurysm Morphodynamics from ECG-gated CT Angiography

    NARCIS (Netherlands)

    Firouzian, A.; Manniesing, R.; Metz, C.T.; Risselada, R.; Klein, S.; Kooten, F. van; Sturkenboom, M.C.; Lugt, A. van der; Niessen, W.J.

    2013-01-01

    Rationale and Objectives: Aneurysm morphodynamics is potentially relevant for assessing aneurysm rupture risk. A method is proposed for automated quantification and visualization of intracranial aneurysm morphodynamics from ECG-gated computed tomography angiography (CTA) data. Materials and Methods:

  14. Incidence and classification of neointimal proliferation and in-stent restenosis in post-stenting patients at 1-year interval: Findings from non-invasive coronary computed tomography angiography

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Nan, E-mail: southmuch@hotmail.com [Department of Radiology, East Hospital, Tongji University School of Medicine, No. 150, Jimo Road, Shanghai 200120 (China); Zhang, Jiayin, E-mail: andrewssmu@msn.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Li, Minghua, E-mail: drliminghua@gmail.com [Department of Radiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Pan, Jingwei, E-mail: drpanjingwei@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China); Lu, Zhigang, E-mail: drluzhigang@gmail.com [Department of Cardiology, Shanghai Jiao Tong University Affiliated Sixth People' s Hospital, No. 600, Yishan Road, Shanghai 200233 (China)

    2014-10-15

    Highlights: • The incidence of silent in-stent restenosis at 1-year as revealed by CT is 7.6%. • The incidence of neointimal proliferation at 1-year as revealed by CT is 12.6%. • Diabetes are associated with higher incidence of neointimal proliferation. - Abstract: Objectives: To evaluate the incidence of coronary in-stent restenosis (ISR) and neointimal proliferation by coronary CT angiography (CCTA) at 1-year follow-up in asymptomatic patients. Methods: 234 patients (mean age: 67 ± 10.2 years, range 39–88 years, 180 males and 54 females) with 379 stents were prospectively enrolled in this study. Binary ISR was classified by CCTA into 4 types using Mehran classification. Neointimal proliferation was similarly classified into focal and diffuse types. All patients with CCTA-revealed ISR or neointimal proliferation underwent further invasive coronary angiography (ICA) for validation. Fisher's exact test was used for comparison. Results: ICA revealed patent stents with neointimal proliferation in 39 patients (16.7%, 39/234) and binary ISR in 23 patients (9.8%, 23/234). Lesion-based analysis showed 12 type I ISR lesions, 4 type II ISR lesions, 1 type III ISR lesion and 7 type IV ISR lesions. Among cases with neointimal proliferation, 27 lesions were classified as focal type whereas 13 lesions were classified as diffuse type. Patients with diabetes mellitus were associated with higher incidence of CCTA-revealed neointimal proliferation (21/77 vs. 18/157, p = 0.002) as well as ISR (12/77 vs. 11/157, p = 0.038), compared to patients without diabetes. CCTA was found to have good diagnostic performance for neointimal proliferation and ISR detection as well as classification, with an overall accuracy of 84.4% (54/64). Conclusions: Silent ISR as well as neointimal proliferation is not uncommon findings in asymptomatic post-stenting patients at 1-year interval, as revealed by CCTA. Patients with diabetes are prone to have higher incidence of neointimal

  15. All-cause mortality benefit of coronary revascularization vs. medical therapy in patients without known coronary artery disease undergoing coronary computed tomographic angiography: results from CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: An InteRnational Multicenter Registry)

    Science.gov (United States)

    Min, James K.; Berman, Daniel S.; Dunning, Allison; Achenbach, Stephan; Al-Mallah, Mouaz; Budoff, Matthew J.; Cademartiri, Filippo; Callister, Tracy Q.; Chang, Hyuk-Jae; Cheng, Victor; Chinnaiyan, Kavitha; Chow, Benjamin J.W.; Cury, Ricardo; Delago, Augustin; Feuchtner, Gudrun; Hadamitzky, Martin; Hausleiter, Joerg; Kaufmann, Philipp; Karlsberg, Ronald P.; Kim, Yong-Jin; Leipsic, Jonathon; Lin, Fay Y.; Maffei, Erica; Plank, Fabian; Raff, Gilbert; Villines, Todd; Labounty, Troy M.; Shaw, Leslee J.

    2012-01-01

    Aims To date, the therapeutic benefit of revascularization vs. medical therapy for stable individuals undergoing invasive coronary angiography (ICA) based upon coronary computed tomographic angiography (CCTA) findings has not been examined. Methods and results We examined 15 223 patients without known coronary artery disease (CAD) undergoing CCTA from eight sites and six countries who were followed for median 2.1 years (interquartile range 1.4–3.3 years) for an endpoint of all-cause mortality. Obstructive CAD by CCTA was defined as a ≥50% luminal diameter stenosis in a major coronary artery. Patients were categorized as having high-risk CAD vs. non-high-risk CAD, with the former including patients with at least obstructive two-vessel CAD with proximal left anterior descending artery involvement, three-vessel CAD, and left main CAD. Death occurred in 185 (1.2%) patients. Patients were categorized into two treatment groups: revascularization (n = 1103; 2.2% mortality) and medical therapy (n = 14 120, 1.1% mortality). To account for non-randomized referral to revascularization, we created a propensity score developed by logistic regression to identify variables that influenced the decision to refer to revascularization. Within this model (C index 0.92, χ2 = 1248, P < 0.0001), obstructive CAD was the most influential factor for referral, followed by an interaction of obstructive CAD with pre-test likelihood of CAD (P = 0.0344). Within CCTA CAD groups, rates of revascularization increased from 3.8% for non-high-risk CAD to 51.2% high-risk CAD. In multivariable models, when compared with medical therapy, revascularization was associated with a survival advantage for patients with high-risk CAD [hazards ratio (HR) 0.38, 95% confidence interval 0.18–0.83], with no difference in survival for patients with non-high-risk CAD (HR 3.24, 95% CI 0.76–13.89) (P-value for interaction = 0.03). Conclusion In an intermediate-term follow-up, coronary revascularization is

  16. Spiral CT angiography for demonstrating cerebral aneurysms before and after treatment with titanium clips; Spiral-CT-Angiographie zur Darstellung von zerebralen Aneurysmen vor und nach Versorgung mit Titan-Clips

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.; Volkmar, C.; Weber, J.; Fink, U.; Holzknecht, N.; Reiser, M. [Institut fuer Radiologische Diagnostik, Klinikum Grosshadern, Universitaet Muenchen (Germany); Yousry, T. [Abteilung fuer Neuroradiologie, Institut fuer Radiologische Diagnostik, Klinikum Grosshadern, Universitaet Muenchen (Germany); Steiger, H.J. [Klinik fuer Neurochirurgie, Klinikum Grosshadern, Universitaet Muenchen (Germany)

    1997-11-01

    Purpose: To determine the suitability of spiral CT angiography (SCTA) in patients with intracerebral titanium aneurysm clips. Material and Method: The section parameters were optimised using a phantom. 16 patients were examined preoperatively and 18 following treatment of aneurysms with clips. Results: The resolution, sensitivity and specificity for demonstrating cerebral aneurysms measuring{>=}3 mm was 91.3% and 75% respectively. In 15 patients with intracerebral clips there were no or only minor artefacts; three examinations were of no value because of major metal artefacts. Amongst six aneurysms demonstrated angiographically, two, which measured more than 3 mm, could be shown by SCTA. Conclusion: SCTA was able to demonstrate intracerebral aneurysms measuring{>=}3 mm. Titanium clips did not usually affect image quality significantly. (orig.) [Deutsch] Ziel: Unsere Untersuchungen sollten die Eignung der Spiral-CT-Angiographie (SCTA) fuer Patienten mit intrazerebralen Titan-Aneurysma-Clips pruefen. Material und Methode: An einem Phantom wurden die Schichtparameter optimiert. 16 Patienten wurden praeopertiv und 18 nach operativer Clippung eines Aneurysmas untersucht. Ergebnisse: Die untere Nachweisgrenze, Sensitivitaet und Spezifitaet fuer den Nachweis von zerebralen Aneurysmen lag bei{>=}3 mm, 91,3% und 75%. Bei Patienten mit intrazerebralen Clips wiesen 15 Untersuchungen keine oder geringe Artefakte auf, drei Untersuchungen konnten wegen ausgepraegter Metallartefakte nicht ausgewertet werden. Von den 6 angiographisch nachweisbaren Restaneurysmen konnten zwei mittels SCTA dargestellt werden, deren Durchmesser ueber 3 mm lag. Schlussfolgerung: Mit der SCTA koennen intrazerebrale Aneurysmen und Restaneurysmen{>=}3 mm nachgewiesen werden. Titanclips beeintraechtigen dabei die Bildqualitaet meist nicht nachhaltig. (orig.)

  17. Cardiac magnetic resonance and computed tomography angiography for clinical imaging of stable coronary artery disease. Diagnostic classification and risk stratification

    Science.gov (United States)

    Korosoglou, Grigorios; Giusca, Sorin; Gitsioudis, Gitsios; Erbel, Christian; Katus, Hugo A.

    2014-01-01

    Despite advances in the pharmacologic and interventional treatment of coronary artery disease (CAD), atherosclerosis remains the leading cause of death in Western societies. X-ray coronary angiography has been the modality of choice for diagnosing the presence and extent of CAD. However, this technique is invasive and provides limited information on the composition of atherosclerotic plaque. Coronary computed tomography angiography (CCTA) and cardiac magnetic resonance (CMR) have emerged as promising non-invasive techniques for the clinical imaging of CAD. Hereby, CCTA allows for visualization of coronary calcification, lumen narrowing and atherosclerotic plaque composition. In this regard, data from the CONFIRM Registry recently demonstrated that both atherosclerotic plaque burden and lumen narrowing exhibit incremental value for the prediction of future cardiac events. However, due to technical limitations with CCTA, resulting in false positive or negative results in the presence of severe calcification or motion artifacts, this technique cannot entirely replace invasive angiography at the present time. CMR on the other hand, provides accurate assessment of the myocardial function due to its high spatial and temporal resolution and intrinsic blood-to-tissue contrast. Hereby, regional wall motion and perfusion abnormalities, during dobutamine or vasodilator stress, precede the development of ST-segment depression and anginal symptoms enabling the detection of functionally significant CAD. While CT generally offers better spatial resolution, the versatility of CMR can provide information on myocardial function, perfusion, and viability, all without ionizing radiation for the patients. Technical developments with these 2 non-invasive imaging tools and their current implementation in the clinical imaging of CAD will be presented and discussed herein. PMID:25147526

  18. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Elijovich, Lucas [NYU Medical Center, Department of Neurology, New York, NY (United States); Kazmi, Khuram [NYU Medical Center, Department of Neurology, New York, NY (United States); NYU Medical Center, Department of Radiology, New York, NY (United States); Gauvrit, Jean Y. [NYU Medical Center, Department of Radiology, New York, NY (United States); Hopital Salengro, Department of Neuroradiology, Lille (France); Law, Meng [NYU Medical Center, Department of Radiology, New York, NY (United States)

    2006-09-15

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  19. Diagnostic accuracy of three-dimensional contrast-enhanced MR angiography at 3-T for acute pulmonary embolism detection: comparison with multidetector CT angiography.

    Science.gov (United States)

    Zhang, Long Jiang; Luo, Song; Yeh, Benjamin M; Zhou, Chang Sheng; Tang, Chun Xiang; Zhao, Yan'e; Li, Lin; Zheng, Ling; Huang, Wei; Lu, Guang Ming

    2013-10-12

    Three-dimensional contrast-enhanced MR pulmonary angiography (MRPA) is a suitable option for pulmonary embolism (PE) detection. However, there have been few reports on the diagnostic accuracy of MRPA for PE detection in a 3-T MR system. The purpose of this study was to evaluate the accuracy of MRPA in a 3-T MR system to detect acute PE with multidetector CT pulmonary angiography (CTPA) as reference standard. Twenty-seven patients (18 males and 9 females, mean age 38.9±14.4 years) underwent both MRPA and CTPA within 3 days (range, 0-3 days) for evaluating PE. Pulmonary emboli in MRPA were independently analyzed on a per-patient and per-lobe basis by two radiologists. CTPA was regarded as reference standard, which was evaluated by another two radiologists in consensus. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for PE detection were calculated. Weighted κ values were calculated to evaluate agreement between readers. Twenty-four patients had PE in 55 lung lobes in CTPA, while 3 patients had no PE detected. Readers 1 and 2 correctly detected 47 and 46 lung lobes having clots in 24 and 23 patients, corresponding to sensitivities, specificities, PPV, NPV, and accuracies of 100%, 100%, 100%, 100%, 100%; 100%, 66.7%, 96.0%, 100%, 96.4% on a per-patient basis and 85.5%, 100%, 100%, 90.9%, 94.1%; 83.6%, 93.7%, 90.2%, 89.2%, 89.6% on a per-lobe basis; respectively. Excellent inter-reader agreement (κ values=1.00 and 0.934; both Pcontrast-enhanced MRPA with a 3-T MR system is a suitable alternative modality to CTPA to detect PE on a per-patient basis based on this small cohort study. © 2013.

  20. Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?

    Energy Technology Data Exchange (ETDEWEB)

    Noergaard, B.L.; Jensen, J.M. [Aarhus University Hospital Skejby, Department of Cardiology B, Aarhus N (Denmark); Leipsic, J. [St. Paul' s Hospital, Department Radiology, Vancouver, British Columbia (Canada)

    2015-08-15

    Fractional flow reserve (FFR) measured during invasive coronary angiography is the gold standard for lesion-specific decisions on coronary revascularization in patients with stable coronary artery disease (CAD). Current guidelines recommend non-invasive functional or anatomic testing as a gatekeeper to the catheterization laboratory. However, the ''holy grail'' in non-invasive testing of CAD is to establish a single test that quantifies both coronary lesion severity and the associated ischemia. Most evidence to date of such a test is based on the addition of computational analysis of FFR to the anatomic information obtained from standard-acquired coronary CTA data sets at rest (FFR{sub CT}). This review summarizes the clinical evidence for the use of FFR{sub CT} in stable CAD in context to the diagnostic performance of other non-invasive testing modalities. (orig.)

  1. [Imaging techniques in the preoperative diagnosis of soft tissue tumors. A comparison of MRT, CT, sonography, angiography and conventional x-rays].

    Science.gov (United States)

    Roeren, T; Gindele, A; Grosspietsch, C; Dueck, M; Kauffmann, G W

    1992-12-01

    In a study on 51 patients with histologically confirmed soft tissue tumors (STT), we retrospectively evaluated the preoperative use of imaging procedures (MRI, CT, ultrasound, angiography, plain film) for identification of tumor size, delineation, and determination of malignancy and tissue type. The findings were correlated with intraoperative findings and histological diagnosis. The overall diagnostic method of choice for preoperative imaging of STT is MRI, followed by CT. Ultrasound, although sensitive, lacks the required specificity. Angiography and plain film can only be used for specific indications, as they generally do not make it possible to stage the tumor. Combining our results with those from the more recent literature, we propose a diagnostic algorithm according to which MRI would generally be performed for preoperative staging of STT. CT and plain film should only be used if bony infiltration is suspected; angiography is indicated for planning intraarterial chemotherapy or embolization or if vascular infiltration is probable.

  2. Imaging of Blood Flow in Cerebral Arteries with Dynamic Helical Computed Tomography Angiography (DHCTA) Using a 64-Row CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Pekkola, J.; Kangasniemi, M. (Helsinki Medical Imaging Center, Helsinki Univ. Central Hospital, Helsinki (Finland))

    2009-08-15

    Background: Cerebral computed tomography angiography (CTA) depicts a structural image of intracranial arteries without providing much time-resolved information on blood flow dynamics. Current CT technology allows obtaining of rapidly repeated helical scans during the arterial contrast filling phase after an intravenous contrast injection. Purpose: To report our experience on dynamic CT imaging in determining the direction of contrast filling within proximal intracranial arteries of operated cerebral artery aneurysm patients. Such dynamic information can help detect vascular occlusion or severe spasm. The method is here referred to as dynamic helical CT angiography (DHCTA). Material and Methods: We retrospectively collected image and related technical data for 23 patients who underwent DHCTA and CTA during their first postoperative day after cerebral artery aneurysm surgery. For DHCTA, we had helically scanned a 4-cm tissue volume three times in succession with a 64-row CT scanner at intervals of 2.6 s during arterial contrast filling after an intravenous contrast injection. We assessed how well DHCTA succeeded in demonstrating the direction of contrast filling in the proximal intracranial arteries, evaluated clinically relevant structural information provided by DHCTA and CTA, and compared radiation doses for the two methods. Results: For 21 patients, DHCTA outlined the direction of contrast filling in proximal intracranial arteries. As to arterial spasm and residual filling of the operated aneurysm, CTA and DHCTA gave similar information. Radiation doses were higher (P<0.000001) for DHCTA than for CTA at 120 kV tube voltage. At 100 kV, the difference was smaller, but doses for DHCTA still exceeded (P<0.05) those for CTA. Conclusion: DHCTA gave dynamic information unobtainable with CTA and could prove useful in selected clinical settings

  3. Coronary CT angiography using prospective ECG triggering. High diagnostic accuracy with low radiation dose; CT-Angiographie der Koronarien mit prospektivem EKG-Triggering. Hohe diagnostische Genauigkeit bei niedriger Strahlendosis

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldi, E. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Klinikum der Ludwigs-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany); Ramos-Duran, L.; Abro, J.A.; Costello, P. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Zwerner, P.L.; Schoepf, U.J. [Medical University of South Carolina, Charleston, Department of Radiology and Radiological Science, Charleston (United States); Medical University of South Carolina, Charleston, Department of Medicine, Division of Cardiology, Charleston (United States); Nikolaou, K.; Reiser, M.F. [Klinikum der Ludwigs-Maximilians-Universitaet Muenchen, Campus Grosshadern, Institut fuer Klinische Radiologie, Muenchen (Germany)

    2010-06-15

    The purpose of this study was to evaluate the diagnostic performance of coronary CT angiography (coronary CTA) using prospective ECG triggering (PT) for the detection of significant coronary artery stenosis compared to invasive coronary angiography (ICA). A total of 20 patients underwent coronary CTA with PT using a 128-slice CT scanner (Definition trademark AS+, Siemens) and ICA. All coronary CTA studies were evaluated for significant coronary artery stenoses ({>=}50% luminal narrowing) by 2 observers in consensus using the AHA-15-segment model. Findings in CTA were compared to those in ICA. Coronary CTA using PT had 88% sensitivity in comparison to 100% with ICA, 95% to 88% specificity, 80% to 92% positive predictive value and 97% to 100% negative predictive value for diagnosing significant coronary artery stenosis on per segment per patient analysis, respectively. Mean effective radiation dose-equivalent of CTA was 2.6{+-}1 mSv. Coronary CTA using PT enables non-invasive diagnosis of significant coronary artery stenosis with high diagnostic accuracy in comparison to ICA and is associated with comparably low radiation exposure. (orig.) [German] Ziel unserer Untersuchungen war es, die CT-Angiographie der Koronarien (Koronar-CTA) unter Verwendung des prospektiven EKG-Triggerings (PT) hinsichtlich ihrer diagnostischen Genauigkeit zur Detektion signifikanter Koronarstenosen mit der Herzkatheteruntersuchung (HK) zu vergleichen. Bei 20 Patienten wurden eine Koronar-CTA mit PT an einem 128-Zeilen-CT-Scanner (Definition trademark, AS+, Siemens) und eine HK durchgefuehrt. Alle CTA-Studien wurden von 2 Radiologen bzgl. signifikanter Koronarstenosen ({>=}50% Lumeneinengung) anhand des 15-Segment-Modells der American Heart Association (AHA) im Konsensus ausgewertet. Die Ergebnisse der CTA wurden mit den Befunden der HK verglichen. Die Koronar-CTA mit PT zeigte fuer die Diagnose signifikanter Stenosen im Vergleich zur HK eine Sensitivitaet von 88 bzw. 100%, eine Spezifitaet

  4. CT reconstruction and MRI fusion of 3D rotational angiography in the evaluation of pediatric cerebrovascular lesions

    Energy Technology Data Exchange (ETDEWEB)

    Muthusami, Prakash; Rea, Vanessa; Shroff, Manohar [The Hospital for Sick Children, Pediatric Neuroradiology and Image Guided Therapy, Department of Diagnostic Imaging, Toronto, ON (Canada); Shkumat, Nicholas [The Hospital for Sick Children, Medical Physics, Department of Diagnostic Imaging, Toronto, ON (Canada); Chiu, Albert H. [Institute of Neurological Sciences, Prince of Wales Hospital, Department of Interventional Neuroradiology, Randwick, NSW (Australia)

    2017-06-15

    Complex neurovascular lesions in children require precise anatomic understanding for treatment planning. Although 3DRA is commonly employed for volumetric reformation in neurointerventional procedures, the ability to reconstruct this data into CT-like images (3DRA-CT) is not widely utilized. This study demonstrates the feasibility and usefulness of 3DRA-CT and subsequent MRI fusion for problem solving in pediatric neuroangiography. This retrospective study includes 18 3DRA-CT studies in 16 children (age 9.6 ± 3.8 years, range 2-16 years) over 1 year. After biplane 2D-digital subtraction angiography (DSA), 5-second 3DRA was performed with selective vessel injection either with or without subtraction. Images were reconstructed into CT sections which were post-processed to generate multiplanar reformation (MPR) and maximum intensity projection (MIP) images. Fusion was performed with 3D T1 MRI images to precisely demonstrate neurovascular relationships. Quantitative radiation metrics were extracted and compared against those for the entire examination and for corresponding biplane 2D-DSA acquisitions. In all 18 cases, the 3DRA procedure and MRI fusion were technically successful and provided clinically useful information relevant to management. The unsubtracted and subtracted 3DRA acquisitions were measured to deliver 5.9 and 132.2%, respectively, of the mean radiation dose of corresponding biplane 2D-DSA acquisitions and contributed 1.2 and 12.5%, respectively, to the total procedure dose. Lower radiation doses, high spatial resolution, and multiplanar reformatting capability make 3DRA-CT a useful adjunct to evaluate neurovascular lesions in children. Fusing 3DRA-CT data with MRI is an additional capability that can further enhance diagnostic information. (orig.)

  5. Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT

    Science.gov (United States)

    Segars, W. P.; Taguchi, K.; Fung, G. S. K.; Fishman, E. K.; Tsui, B. M. W.

    2006-03-01

    We investigate the effect of heart rate on the quality and artifact generation in coronary artery images obtained using multi-slice computed tomography (MSCT) with the purpose of finding the optimal time resolution for data acquisition. To perform the study, we used the 4D NCAT phantom, a computer model of the normal human anatomy and cardiac and respiratory motions developed in our laboratory. Although capable of being far more realistic, the 4D NCAT cardiac model was originally designed for low-resolution imaging research, and lacked the anatomical detail to be applicable to high-resolution CT. In this work, we updated the cardiac model to include a more detailed anatomy and physiology based on high-resolution clinical gated MSCT data. To demonstrate its utility in high-resolution dynamic CT imaging research, the enhanced 4D NCAT was then used in a pilot simulation study to investigate the effect of heart rate on CT angiography. The 4D NCAT was used to simulate patients with different heart rates (60-120 beats/minute) and with various cardiac plaques of known size and location within the coronary arteries. For each simulated patient, MSCT projection data was generated with data acquisition windows ranging from 100 to 250 ms centered within the quiet phase (mid-diastole) of the heart using an analytical CT projection algorithm. CT images were reconstructed from the projection data, and the contrast of the plaques was then measured to assess the effect of heart rate and to determine the optimal time resolution required for each case. The 4D NCAT phantom with its realistic model for the cardiac motion was found to provide a valuable tool from which to optimize CT cardiac applications. Our results indicate the importance of optimizing the time resolution with regard to heart rate and plaque location for improved CT images at a reduced patient dose.

  6. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  7. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Juan; Sun, Gang; Yu, Bling Bing; Li, Min; Li, Guo Ying; Peng, Zhao Hui; Zhang, Xu Ping [Dept. of Medical Imaging, Jinan Military General Hospital, Jinan (China); Lu, Yang [Dept. of Radiology, University of Illinois College of Medicine, Illinois (United States)

    2012-11-15

    To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 {+-} 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 {+-} 0.01 mSv) (p < 0.001). 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.

  8. Sequential SPECT/CT imaging starting with stress SPECT in patients with left bundle branch block suspected for coronary artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Engbers, Elsemiek M.; Mouden, Mohamed [Isala, Department of Cardiology, Zwolle (Netherlands); Isala, Department of Nuclear Medicine, Zwolle (Netherlands); Timmer, Jorik R.; Ottervanger, Jan Paul [Isala, Department of Cardiology, Zwolle (Netherlands); Knollema, Siert; Jager, Pieter L. [Isala, Department of Nuclear Medicine, Zwolle (Netherlands)

    2017-01-15

    To investigate the impact of left bundle branch block (LBBB) on sequential single photon emission computed tomography (SPECT)/ CT imaging starting with stress-first SPECT. Consecutive symptomatic low- to intermediate-risk patients without a history of coronary artery disease (CAD) referred for SPECT/CT were included from an observational registry. If stress SPECT was abnormal, additional rest SPECT and, if feasible, coronary CT angiography (CCTA) were acquired. Of the 5,018 patients, 218 (4.3 %) demonstrated LBBB. Patients with LBBB were slightly older than patients without LBBB (65±12 vs. 61±11 years, p<0.001). Stress SPECT was more frequently abnormal in patients with LBBB (82 % vs. 46 %, p<0.001). After reviewing stress and rest images, SPECT was normal in 43 % of the patients with LBBB, compared to 77 % of the patients without LBBB (p<0.001). Sixty-four of the 124 patients with LBBB and abnormal stress-rest SPECT underwent CCTA (52 %), which could exclude obstructive CAD in 46 of the patients (72 %). Sequential SPECT/CT imaging starting with stress SPECT is not the optimal imaging protocol in patients with LBBB, as the majority of these patients have potentially false-positive stress SPECT. First-line testing using CCTA may be more appropriate in low- to intermediate-risk patients with LBBB. (orig.)

  9. Head-to-head comparison between {sup 18}F-FDOPA PET/CT and MR/CT angiography in clinically recurrent head and neck paragangliomas

    Energy Technology Data Exchange (ETDEWEB)

    Heimburger, Celine; Hubele, Fabrice; Namer, Izzie Jacques [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Veillon, Francis; Riehm, Sophie; Cavalcanti, Marcela [University Hospitals of Strasbourg, Department of Radiology, Strasbourg (France); Taieb, David [Aix-Marseille University, Department of Nuclear Medicine, La Timone University Hospital, Marseille (France); Aix-Marseille University, European Center for Research in Medical Imaging, Marseille (France); Institut Paoli-Calmettes, Inserm UMR1068 Marseille Cancerology Research Center, Marseille (France); Goichot, Bernard; Chabrier, Gerard [University Hospitals of Strasbourg, Department of Internal Medicine, Strasbourg (France); Petit-Thomas, Julie; Charpiot, Anne [University Hospitals of Strasbourg, Department of Otolaryngology and Maxillofacial Surgery, Strasbourg (France); Averous, Gerlinde [University Hospitals of Strasbourg, Department of Pathology, Strasbourg (France); Imperiale, Alessio [University Hospitals of Strasbourg, Department of Biophysics and Nuclear Medicine, Strasbourg (France); CNRS/University of Strasbourg, ICube, UMR 7357, Strasbourg (France); University of Strasbourg, FMTS, Faculty of Medicine, Strasbourg (France); Hautepierre University Hospital, Biophysics and Nuclear Medicine, Strasbourg Cedex (France)

    2017-06-15

    Head and neck paragangliomas (HNPGLs) can relapse after primary treatment. Optimal imaging protocols have not yet been established for posttreatment evaluation. The aim of the present study was to assess the diagnostic value of {sup 18}F-FDOPA PET/CT and MR/CT angiography (MRA/CTA) in HNPGL patients with clinical relapse during their follow-up. Sixteen consecutive patients presenting with local pain, tinnitus, dysphagia, hoarse voice, cranial nerve involvement, deafness, or retrotympanic mass appearing during follow-up after the initial treatment of HNPGLs were retrospectively evaluated. Patients underwent both {sup 18}F-FDOPA PET/CT and MRA (15 patents) or CTA (1 patent). Both methods were first assessed under blinded conditions and afterwards correlated. Head and neck imaging abnormalities without histological confirmation were considered true-positive results based on a consensus between radiologists and nuclear physicians and on further {sup 18}F-FDOPA PET/CT and/or MRA. {sup 18}F-FDOPA PET/CT and MRA/CTA were concordant in 14 patients and in disagreement in 2 patients. {sup 18}F-FDOPA PET/CT and MRA/CTA identified, respectively, 12 and 10 presumed recurrent HNPGLs in 12 patients. The two lesions diagnosed by PET/CT only were confirmed during follow-up by otoscopic examination and MRA performed 29 and 17 months later. {sup 18}F-FDOPA PET/CT images were only slightly influenced by the posttreatment sequelae, showing a better interobserver reproducibility than MRA/CTA. Finally, in 2 of the 16 studied patients, {sup 18}F-FDOPA PET/CT detected two additional synchronous primary HNPGLs. {sup 18}F-FDOPA PET/CT is highly sensitive in posttreatment evaluation of patients with HNPGLs, and also offers better interobserver reproducibility than MRA/CTA and whole-body examination. We therefore suggest that {sup 18}F-FDOPA PET/CT is performed as the first diagnostic imaging modality in symptomatic patients with suspicion of HNPGL relapse after primary treatment when {sup 68

  10. Tube potential can be lowered to 80 kVp in test bolus phase of CT coronary angiography (CTCA) and CT pulmonary angiography (CTPA) to save dose without compromising diagnostic quality

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, J.C.L.; Manghat, N.E.; Hamilton, M.C.K. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); University Hospitals Bristol NHS Foundation Trust, National Institute for Health Research (NIHR) Cardiovascular Biomedical Research Unit, Bristol Heart Institute, Bristol Royal Infirmary, Bristol (United Kingdom); Joshi, D.; Lyen, S.M. [University Hospitals Bristol NHS Foundation Trust, Department of Radiology, Bristol Royal Infirmary, Bristol (United Kingdom); Negus, I.S. [University Hospitals Bristol NHS Foundation Trust, Department of Medical Physics and Bioengineering, Bristol Royal Infirmary, Bristol (United Kingdom)

    2014-10-15

    The purpose of this study was to determine whether performing the test bolus (TB) of computed tomography coronary angiography (CTCA) and computed tomography pulmonary angiography (CTPA) at 80 kVp reduces dose without compromising diagnostic quality. An 80 kVp TB protocol for CTCA and CTPA was retrospectively compared to standard TB protocol (non-obese: 100 kVp, obese: 120 kVp). CT angiogram parameters were unchanged between cohorts. Thirty-seven consecutive 80 kVp TB CTCA images were compared to 53 standard CTCA images. Fifty consecutive CTPAs from each protocol were analysed. Diagnostic quality of the CT angiogram was assessed by: mean attenuation, signal-to-noise ratio (SNR) in the ascending aorta (AA) in CTCA and in the main pulmonary artery (MPA) in CTPA, diagnostic rate, and number of repeated monitoring scans. Mean effective dose was estimated using the dose-length product. Mean TB effective doses were significantly lower (P < 0.0001) for 80 kVp scans compared to the standard in non-obese CTCA (0.15 ± 0.04 mSv Vs 0.33 ± 0.09 mSv), obese CTCA (0.17 ± 0.06 mSv Vs 0.57 ± 0.12 mSv), and CTPA patients (0.07 ± 0.03 mSv Vs 0.15 ± 0.06 mSv). No difference was demonstrated in mean attenuation, SNR (AA), SNR (MPA), diagnostic rates, or number of repeated monitoring scans between protocols. Routinely performing TB at 80 kVp, regardless of body habitus, in CTCA and CTPA results in a small but significant dose reduction, without compromising CT angiogram diagnostic quality. (orig.)

  11. The safe practice of CT coronary angiography in adult patients in UK imaging departments.

    Science.gov (United States)

    Harden, S P; Bull, R K; Bury, R W; Castellano, E A; Clayton, B; Hamilton, M C K; Morgan-Hughes, G J; O'Regan, D; Padley, S P G; Roditi, G H; Roobottom, C A; Stirrup, J; Nicol, E D

    2016-08-01

    Computed tomography coronary angiography is increasingly used in imaging departments in the investigation of patients with chest pain and suspected coronary artery disease. Due to the routine use of heart rate controlling medication and the potential for very high radiation doses during these scans, there is a need for guidance on best practice for departments performing this examination, so the patient can be assured of a good quality scan and outcome in a safe environment. This article is a summary of the document on 'Standards of practice of computed tomography coronary angiography (CTCA) in adult patients' published by the Royal College of Radiologists (RCR) in December 2014.

  12. Improving CCTA-based lesions' hemodynamic significance assessment by accounting for partial volume modeling in automatic coronary lumen segmentation.

    Science.gov (United States)

    Freiman, Moti; Nickisch, Hannes; Prevrhal, Sven; Schmitt, Holger; Vembar, Mani; Maurovich-Horvat, Pál; Donnelly, Patrick; Goshen, Liran

    2017-03-01

    The goal of this study was to assess the potential added benefit of accounting for partial volume effects (PVE) in an automatic coronary lumen segmentation algorithm that is used to determine the hemodynamic significance of a coronary artery stenosis from coronary computed tomography angiography (CCTA). Two sets of data were used in our work: (a) multivendor CCTA datasets of 18 subjects from the MICCAI 2012 challenge with automatically generated centerlines and 3 reference segmentations of 78 coronary segments and (b) additional CCTA datasets of 97 subjects with 132 coronary lesions that had invasive reference standard FFR measurements. We extracted the coronary artery centerlines for the 97 datasets by an automated software program followed by manual correction if required. An automatic machine-learning-based algorithm segmented the coronary tree with and without accounting for the PVE. We obtained CCTA-based FFR measurements using a flow simulation in the coronary trees that were generated by the automatic algorithm with and without accounting for PVE. We assessed the potential added value of PVE integration as a part of the automatic coronary lumen segmentation algorithm by means of segmentation accuracy using the MICCAI 2012 challenge framework and by means of flow simulation overall accuracy, sensitivity, specificity, negative and positive predictive values, and the receiver operated characteristic (ROC) area under the curve. We also evaluated the potential benefit of accounting for PVE in automatic segmentation for flow simulation for lesions that were diagnosed as obstructive based on CCTA which could have indicated a need for an invasive exam and revascularization. Our segmentation algorithm improves the maximal surface distance error by ~39% compared to previously published method on the 18 datasets from the MICCAI 2012 challenge with comparable Dice and mean surface distance. Results with and without accounting for PVE were comparable. In contrast

  13. Noninvasive Detection of Coronary Artery Stenosis Using 16-slice Spiral CT: a Comparison with Selective X-ray Coronary Angiography

    Institute of Scientific and Technical Information of China (English)

    SHI Heshui; HAN Ping; KONG Xiangquan; FENG Gansheng; Martin HK Hoffmann

    2006-01-01

    The role of 16-slice spiral CT was evaluated in the diagnosis of coronary stenosis, with selective X-ray coronary angiography (SCA) serving as the reference standard. Sixty-five patients who were suspected of having coronary heart disease, without percutaneous transluminal coronary angioplasty or coronary bypass-grafting, were investigated using 16-slice CT. Eight patients with pre-scan heart rate of more than 80 beats/min were given β-blockers. After the retrospectively ECG-gated axial imaging reconstruction, volume redering (VR), multi-planar reconstruction (MPR), curved MPR and maximum intensity projection (MIP) were used to reconstruct. Every segment of coronary artery with a diameter ≥1.5 mm was assessed, and the presence on CT with a stenosis exceeding 50% diameter reduction was compared with that on SCA. The reasons which lead to some segments unevaluable were analysed. Compared with SCA, 93% coronary segments and 94 % main branches were evaluable. Residual cardiac motion artifacts, severe calcification and poor opacification made 58%, 28% and 14% of the remaining 60 segments unevaluable respectively. Without routine administration of β-blockers, good coronary imaging quality can be acquired using 16-slice spiral CT. It is a reliable noninvasive method for detection of obstructive coronary artery disease.

  14. Preoperative CT-Angiography Predicts Ex Vivo Vein Length for Right Kidneys After Laparoscopic Donor Nephrectomy

    NARCIS (Netherlands)

    Özdemir-van Brunschot, D.M.D.; Rottier, S.J.; Ouden, J.E. den; Jagt, M.F.P. van der; D'Ancona, F.C.H.; Kloke, H.J.; Vliet, D. van der; Schultze Kool, L.J.; Warle, M.C.

    2015-01-01

    BACKGROUND Implantation of a kidney with a short renal vein is technically more challenging and therefore prone for technique-related complications. It remains unclear whether pre-operative computed tomography angiography (CTA), to assess vascular anatomy of the donor kidney, can be used to predict

  15. Pre-treatment with a sinus node blockade, ivabradine, before coronary CT angiography

    DEFF Research Database (Denmark)

    Lambrechtsen, J; Egstrup, K

    2013-01-01

    To evaluate whether a simple pre-treatment regimen of sinus node inhibition by ivabradine taken at home for only 1 day resulted in a lower pre-scanning heart rate (HR) and reduced the need for intravenous beta-blockers (BB) prior to coronary computed tomography angiography (CTA)....

  16. Flat-detector computed tomography with intravenous contrast material application in experimental aneurysms: comparison with multislice CT and conventional angiography.

    Science.gov (United States)

    Struffert, Tobias; Doelken, Marc; Adamek, Edyta; Schwarz, Marc; Engelhorn, Tobias; Kloska, Stephan; Ott, Sabine; Doerfler, Arnd

    2010-05-01

    Despite limited soft tissue resolution flat-detector computed tomography (FD-CT) provides substantial superior spatial resolution in comparison with multislice computed tomography (MS-CT). This may add value in the visualization of small vascular structures if intravenous contrast application leads to substantial opacification and visibility of intracranial vessels or aneurysms. To evaluate the feasibility of visualization of vascular structures by FD-CT angiography (FD-CTA) after intravenous contrast injection compared with MS-CTA and intra-arterial digital subtracted angiography (IADSA) in an animal model. Aneurysms were created in the right common carotid artery in six New Zealand White Rabbits using the elastase technique. Imaging was performed using FD-CTA, MS-CTA (injection of 1 ml/kg body weight) and IADSA. Anonymized volume rendering reconstruction (VRT), maximum intensity projection (MIP), and multiplanar reconstruction (MPR) images were reconstructed and evaluated by two experienced reviewers for aneurysm geometry and vascular structure anatomy using standard tools of a dedicated workstation. Aneurysms could be successfully created in all animals. Measurements of aneurysm geometry (aneurysm height, width, neck width) and vascular structures (brachiocephalic trunk, carotid artery diameter and plane) were nearly identical in all three modalities. Intra- and inter-observer correlations of the different parameters showed high r values between 0.83 and 0.99. Our results show the feasibility of FD-CTA in comparison with MS-CTA and IADSA in an animal model. Despite limited soft tissue resolution, opacification of vascular structures with sufficient contrast to the surrounding structures was possible in all animals. Vascular structures appeared better delineated in FD-CTA than in MS-CTA, probably due to the superior spatial resolution.

  17. Automatic selection of an optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography

    Science.gov (United States)

    Seifarth, H.; Puesken, M.; Wienbeck, S.; Maintz, D.; Heindel, W.; Juergens, K.-U.

    2008-03-01

    Purpose: To assess the performance of a motion map algorithm to automatically determine the optimal systolic and diastolic reconstruction window for coronary CT Angiography using Dual Source CT. Materials and Methods: Dual Source coronary CT angiography data sets (Somatom Definition, Siemens Medical Solutions) from 50 consecutive patients were included in the analysis. Optimal systolic and diastolic reconstruction windows were determined using a motion map algorithm (BestPhase, Siemens Medical Solutions). Additionally data sets were reconstructed in 5% steps throughout the RR-interval. For each major vessel (RCA, LAD and LCX) an optimal systolic and diastolic reconstruction window was manually determined by two independent readers using volume rendering displays. Image quality was rated using a five-point scale (1 = no motion artifacts, 5 = severe motion artifacts over entire length of the vessel). Results: The mean heart rate during the scan was 72.4bpm (+/-15.8bpm). Median systolic and diastolic reconstruction windows using the BestPhase algorithm were at 37% and 73% RR. The median manually selected systolic reconstruction window was 35 %, 30% and 35% for RCA, LAD, and LCX. For all vessels the median observer selected diastolic reconstruction window was 75%. Mean image quality using the BestPhase algorithm was 2.4 +/-0.9 for systolic reconstructions and 1.9 +/-1.1 for diastolic reconstructions. Using the manual approach, the mean image quality was 1.9 +/-0.5 and 1.7 +/-0.8 respectively. There was a significant difference in image quality between automatically and manually determined systolic reconstructions (p<0.01) but there was no significant difference in image quality in diastolic reconstructions. Conclusion: Automatic determination of the optimal reconstruction interval using the BestPhase algorithm is feasible and yields reconstruction windows similar to observer selected reconstruction windows. In diastolic reconstructions overall image quality is similar

  18. DIAGNÓSTICO DE UN TROMBOEMBOLISMO PULMONAR AGUDO POR ANGIOTC / Diagnosis of acute pulmonary thomboembolism by CT angiography

    Directory of Open Access Journals (Sweden)

    Mario E. Nápoles Lizano

    2012-10-01

    Full Text Available ResumenEl tromboembolismo pulmonar agudo tiene mayor morbilidad y mortalidad en los ancianos, pero puede presentarse en adultos jóvenes; por eso el diagnóstico certero es muy importante en este grupo etario. En este artículo se presenta el caso de un hombre de 37 años de edad, que acude al cuerpo de guardia por dolor precordial, sin alteraciones electrocardiográficas y dilatación de las cavidades derechas en el ecocardiograma. Se realizó AngioTC y se observó una dilatación del tronco de la arteria pulmonar, donde había una imagen hipodensa que ocupaba su porción distal, en relación con tromboembolismo pulmonar agudo. El paciente evolucionó favorablemente con el tratamiento. Mediante este estudio, se evidencia la importancia del AngioTC con tomógrafo de doble fuente, para la evaluación del dolor torácico agudo, en el paciente que no tiene manifestaciones electrocardiográficas, ni enzimáticas de infarto agudo de miocardio. / AbstractAcute pulmonary thromboembolism have increased morbidity and mortality in the elderly, but it can also occur in young adults, which is why an accurate diagnosis is very important in this age group. This article presents the case of a 37-year-old man, who comes to the emergency room for chest pain without electrocardiographic abnormalities and dilatation of the right chambers on echocardiography. CT angiography was performed and it showed a dilated pulmonary trunk, where there was a hypodense image occupying its distal portion, in relation to acute pulmonary thromboembolism. The patient responded favorably to treatment. Through this study, the importance of CT angiography with dual-source CT scanner for evaluation of acute chest pain, in patients with no electrocardiographic manifestations or enzymatic myocardial infarction is demonstrated.

  19. Myocardial contrast defect associated with thrombotic coronary occlusion: Pre-autopsy diagnosis of a cardiac death with post-mortem CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon; Cha, Jang Gyu [Dept. of Radiology, Soonchunhyang University Hospital, Bucheon (Korea, Republic of); Park, Hye Jin; Lee, Soo Kyoung; Yang, Kyung Moo [Dept. of Forensic Medicine, National Forensic Service, Wonju (Korea, Republic of)

    2015-10-15

    We report the case of a female who died of suspected acute myocardial infarction. Post-mortem CT angiography (PMCTA) was performed with intravascular contrast infusion before the standard autopsy, and it successfully demonstrated the complete thrombotic occlusion of a coronary artery and also a corresponding perfusion defect on myocardium. We herein describe the PMCTA findings of a cardiac death with special emphasis on the potential benefits of this novel CT technique in forensic practice.

  20. CT angiography with three-dimensional techniques for the early diagnosis of intracranial aneurysms. Comparison with intra-arterial DSA and the surgical findings

    Energy Technology Data Exchange (ETDEWEB)

    Karamessini, Maria T.; Kagadis, George C.; Petsas, Theodore; Karnabatidis, Dimitrios; Konstantinou, Dimitrios; Sakellaropoulos, George C.; Nikiforidis, George C.; Siablis, Dimitrios E-mail: siablis@med.upatras.gr

    2004-03-01

    Introduction: Cerebral CT angiography (CTA) is an established method applied to both the detection and treatment planning of intracranial aneurysms. The aim of our study was to compare CTA and digital subtraction angiography (DSA) findings with the surgical results mainly in patients with acute SAH and to evaluate the clinical usefulness of CTA. Materials and methods: During the last 2 years, 82 consecutive patients were admitted under clinical symptoms and signs suggestive of harboring an intracranial aneurysm. CT angiography performed immediately afterwards the plain CT, while DSA was performed within the first 48 h of admission. All aneurysms detected were confirmed during surgery or endovascular embolization. Repeat DSA was performed in all patients having both the initial CTA and the DSA 15 days after the onset of symptoms negative. CT angiograms and conventional angiographies were studied by a consensus of two radiologists for each technique, who performed aneurysm detection, morphological features characterization and evaluation of the technique. Results: Surgical or/and endovascular treatment was performed in 45 patients and 53 aneurysms were confirmed. Using 3D-CT angiography, we detected 47 aneurysms in 42 patients. Conventional angiography depicted 43 aneurysms in 39 patients. The sensitivity of CTA for the detection of all aneurysms versus surgery was 88.7%, the specificity 100%, the positive predictive value (PPV) 100%, the negative predictive value (NPV) 80.7% and the accuracy 92.3%. Accordingly, the sensitivity of DSA was 87.8%, the specificity 98%, the PPV 97.7%, the NPV 89.1% and the accuracy 92.9%. Considering aneurysms {>=}3 mm, CTA showed a sensitivity ranging from 93.3 to 100%, equal to that of DSA. Conclusion: Cerebral CT angiography has an equal sensitivity to DSA in the detection of intracranial aneurysms >3 mm. It has also 100% detection rate in AcoA and MCA bifurcation aneurysms, while some locations, like posterior communicating artery

  1. Didactics and training in cardiovascular computed tomography angiography.

    Science.gov (United States)

    Bhojraj, Sanjay D; Al-Mallah, Mouaz H

    2009-01-01

    As the role of cardiovascular computed tomography angiography (CCTA) is further expanded through research, the use of this technology will expand as a result of demand both from medical professionals and the public. To ensure a standardized quality of interpretation of these scans in the face of an increased demand for physicians qualified to interpret these studies, the Society of Cardiovascular Computed Tomography, along with several other professional societies, has proposed a didactic curriculum for the study of CCTA. This review highlights the currently proposed didactic curriculum for the study of CCTA, examines current trends in training for both medical trainees and physicians in practice, and proposes future directions for the study of CCTA.

  2. Role of multi-slice CT coronary angiography in evaluating the different patterns of coronary artery disease in patients with unstable angina

    Directory of Open Access Journals (Sweden)

    Gamal Eldine M. Niazi

    2015-09-01

    Conclusion: Non-invasive multi-slice CT coronary angiography is a reliable technique of high ability to detect coronary artery disease and estimate the degree of obstruction, number of affected arteries and the pattern of their affection and can be used in workup in patients with unstable angina.

  3. Acute subarachnoid hemorrhage: using 64-slice multidetector CT angiography to ''triage'' patients' treatment

    Energy Technology Data Exchange (ETDEWEB)

    Agid, R.; Lee, S.K.; Willinsky, R.A.; Farb, R.I.; TerBrugge, K.G. [Toronto Western Hospital, Division of Neuroradiology, Department of Medical Imaging, Toronto, Ontario (Canada)

    2006-11-15

    To evaluate the clinical role of CT angiography (CTA) in patients with acute subarachnoid hemorrhage (SAH) for treatment decision-making. Consecutive patients with acute SAH had CTA using a 64-slice scanner for initial clinical decision-making. Image processing included multiplanar volume reformatted (MPVR) maximum intensity projections (MIP) and 3D volume-rendered reconstructions. CTAs were used for (1) evaluating the cause of SAH, and (2) triaging aneurysm-bearing patients to the more appropriate management, either surgical clipping or endovascular coiling. CTA findings were confirmed by neurosurgical exploration or catheter angiography (digital subtraction angiography, DSA). Successful coiling provided evidence that triaging to endovascular treatment was correct. Included in the study were 73 patients. CTA findings were confirmed by DSA or neurosurgical operation in 65 patients, and of these 65, 47 had aneurysmal SAH, 3 had vasculitis, 1 had arterial dissection and 14 had no underlying arterial abnormality. The cause of SAH was detected with CTA in 62 out of the 65 patients (95.4%, sensitivity 94%, specificity 100%). CTA revealed the aneurysm in 46 of 47 patients (98%, sensitivity 98%, specificity 100%, positive predictive value 100%, negative predictive value 82.3%), 1 of 3 vasculitides and 1 of 1 dissection. Of the 46 patients with aneurysm, 44 (95.7%) were referred for treatment based on CTA. In 2 patients (2 of 46, 4.4%) CTA was not informative enough to choose treatment requiring DSA. Of the 44 patients, 27 (61.4%) were referred to endovascular treatment and successful coiling was achieved in 25 (25 of 27, 92.6%). CTA using a 64-slice scanner is an accurate tool for detecting and characterizing aneurysms in acute SAH. CTA is useful in the decision process whether to coil or clip an aneurysm. (orig.)

  4. Observer reliability of CT angiography in the assessment of acute ischaemic stroke: data from the Third International Stroke Trial

    Energy Technology Data Exchange (ETDEWEB)

    Mair, Grant; Farrall, Andrew J.; Sellar, Robin J.; Mollison, Daisy; Sakka, Eleni; Palmer, Jeb; Wardlaw, Joanna M. [University of Edinburgh, Western General Hospital, Division of Neuroimaging Sciences, Edinburgh (United Kingdom); Kummer, Ruediger von [Dresden University Stroke Centre, University Hospital, Department of Neuroradiology, Dresden (Germany); Adami, Alessandro [Sacro Cuore-Don Calabria Hospital, Stroke Center, Department of Neurology, Negrar (Italy); White, Philip M. [Stroke Research Group, Newcastle upon Tyne (United Kingdom); Adams, Matthew E. [National Hospital for Neurology and Neurosurgery, Department of Neuroradiology, London (United Kingdom); Yan, Bernard [Royal Melbourne Hospital, Neurovascular Research Group, Parkville (Australia); Demchuk, Andrew M. [Calgary Stroke Program, Department of Clinical Neurosciences, Calgary (Canada); Ramaswamy, Rajesh; Rodrigues, Mark A.; Samji, Karim; Baird, Andrew J. [Royal Infirmary of Edinburgh, Department of Radiology, Edinburgh (United Kingdom); Boyd, Elena V. [Northwick Park Hospital, Department of Radiology, Harrow (United Kingdom); Cohen, Geoff; Perry, David; Sandercock, Peter A.G. [University of Edinburgh, Western General Hospital, Division of Clinical Neurosciences, Edinburgh (United Kingdom); Lindley, Richard [University of Sydney, Westmead Hospital Clinical School and The George Institute for Global Health, Sydney (Australia); Collaboration: The IST-3 Collaborative Group

    2014-10-07

    CT angiography (CTA) is often used for assessing patients with acute ischaemic stroke. Only limited observer reliability data exist. We tested inter- and intra-observer reliability for the assessment of CTA in acute ischaemic stroke. We selected 15 cases from the Third International Stroke Trial (IST-3, ISRCTN25765518) with various degrees of arterial obstruction in different intracranial locations on CTA. To assess inter-observer reliability, seven members of the IST-3 expert image reading panel (>5 years experience reading CTA) and seven radiology trainees (<2 years experience) rated all 15 scans independently and blind to clinical data for: presence (versus absence) of any intracranial arterial abnormality (stenosis or occlusion), severity of arterial abnormality using relevant scales (IST-3 angiography score, Thrombolysis in Cerebral Infarction (TICI) score, Clot Burden Score), collateral supply and visibility of a perfusion defect on CTA source images (CTA-SI). Intra-observer reliability was assessed using independently repeated expert panel scan ratings. We assessed observer agreement with Krippendorff's-alpha (K-alpha). Among experienced observers, inter-observer agreement was substantial for the identification of any angiographic abnormality (K-alpha = 0.70) and with an angiography assessment scale (K-alpha = 0.60-0.66). There was less agreement for grades of collateral supply (K-alpha = 0.56) or for identification of a perfusion defect on CTA-SI (K-alpha = 0.32). Radiology trainees performed as well as expert readers when additional training was undertaken (neuroradiology specialist trainees). Intra-observer agreement among experts provided similar results (K-alpha = 0.33-0.72). For most imaging characteristics assessed, CTA has moderate to substantial observer agreement in acute ischaemic stroke. Experienced readers and those with specialist training perform best. (orig.)

  5. [Evaluation of the variable-speed injection method for three-dimensional CT angiography of the trunk].

    Science.gov (United States)

    Muroga, Koji; Hatcho, Atsushi; Terasawa, Kazuaki

    2005-01-20

    In three-dimensional CT angiography (3DCTA) studies, the CT values within blood vessels ideally should be uniform because the reproducibility and detectability of the morphological characteristics of blood vessels change depending on the threshold value selected. The time-density curve (TDC) therefore should be maintained at a certain level. However, conventional contrast medium injectors have a fixed injection speed, and the injection speed must therefore be changed in a stepwise manner. This means that it is not possible to maintain the TDC precisely. However, recent advances in the performance capabilities of contrast medium injectors allow the injection speed to be changed continuously with a user-selectable injection-speed ratio, permitting studies to be performed using the so-called "variable-speed injection method". We have conducted studies using this new method to determine the optimal injection speed ratio that permits the TDC to be maintained at the desired level. Our results showed that an injection-speed ratio of 0.5 permits the TDC to be maintained at the optimal level, improving the reproducibility and detectability of blood vessel morphology in 3DCTA studies. In addition, when contrast medium injection was terminated at a time point > or =50% of the preset contrast medium injection time, the mean CT value was not adversely affected (i.e., was not significantly reduced), making it possible to reduce the amount of contrast medium administered to the patient.

  6. Evaluation of radiation dose of triple rule-out coronary angiography protocols with different scan length using 256-slice CT

    Science.gov (United States)

    Tsai, Chia-Jung; Lee, Jason J. S.; Chen, Liang-Kuang; Mok, Greta S. P.; Hsu, Shih-Ming; Wu, Tung-Hsin

    2011-10-01

    Triple rule-out coronary CT angiography (TRO-CTA) is a new approach for providing noninvasive visualization of coronary arteries with simultaneous evaluation of pulmonary arteries, thoracic aorta and other intrathoracic structures. The increasing use of TRO-CTA examination with longer scan length is associated with the concerns about radiation dose and their corresponding cancer risk. The purpose of this study is to evaluate organ dose and effective dose for the TRO-CTA examination with 2 scan lengths: TRO std and TRO ext, using 256-slice CT. TRO-CTA examinations were performed on a 256-slice CT scanner without ECG-based tube current modulation. Absorbed organ doses were measured using an anthropomorphic phantom and thermal-luminance dosimeters (TLDs). Effective dose was determined by taking a sum of the measured absorbed organ doses multiplied with the tissue weighting factor based on ICRP-103, and compared to that calculated using the dose-length product (DLP) method. We obtained high organ doses in the thyroid, esophagus, breast, heart and lung in both TRO-CTA protocols. Effective doses of the TRO std and TRO ext protocols with the phantom method were 26.37 and 42.49 mSv, while those with the DLP method were 19.68 and 38.96 mSv, respectively. Our quantitative dose information establishes a relationship between radiation dose and scanning length, and can provide a practical guidance to best clinical practice.

  7. Real-time fusion of coronary CT angiography with X-ray fluoroscopy during chronic total occlusion PCI

    Energy Technology Data Exchange (ETDEWEB)

    Ghoshhajra, Brian B.; Takx, Richard A.P. [Harvard Medical School, Cardiac MR PET CT Program, Massachusetts General Hospital, Department of Radiology and Division of Cardiology, Boston, MA (United States); Stone, Luke L.; Yeh, Robert W.; Jaffer, Farouc A. [Harvard Medical School, Cardiac Cathetrization Laboratory, Cardiology Division, Massachusetts General Hospital, Boston, MA (United States); Girard, Erin E. [Siemens Healthcare, Princeton, NJ (United States); Brilakis, Emmanouil S. [Cardiology Division, Dallas VA Medical Center and UT Southwestern Medical Center, Dallas, TX (United States); Lombardi, William L. [University of Washington, Cardiology Division, Seattle, WA (United States)

    2017-06-15

    The purpose of this study was to demonstrate the feasibility of real-time fusion of coronary computed tomography angiography (CTA) centreline and arterial wall calcification with X-ray fluoroscopy during chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Patients undergoing CTO PCI were prospectively enrolled. Pre-procedural CT scans were integrated with conventional coronary fluoroscopy using prototype software. We enrolled 24 patients who underwent CTO PCI using the prototype CT fusion software, and 24 consecutive CTO PCI patients without CT guidance served as a control group. Mean age was 66 ± 11 years, and 43/48 patients were men. Real-time CTA fusion during CTO PCI provided additional information regarding coronary arterial calcification and tortuosity that generated new insights into antegrade wiring, antegrade dissection/reentry, and retrograde wiring during CTO PCI. Overall CTO success rates and procedural outcomes remained similar between the two groups, despite a trend toward higher complexity in the fusion CTA group. This study demonstrates that real-time automated co-registration of coronary CTA centreline and calcification onto live fluoroscopic images is feasible and provides new insights into CTO PCI, and in particular, antegrade dissection reentry-based CTO PCI. (orig.)

  8. Diagnostic value of 64-slice spiral CT angiography in the diagnosis of multiple intracranial aneurysms: a report of 25 cases

    Directory of Open Access Journals (Sweden)

    Hong-sheng WANG

    2013-02-01

    Full Text Available Objective  To evaluate the diagnostic value of 64-slice spiral CT angiography (CTA in multiple intracranial aneurysms (MIA. Methods  Twenty-five patients (9 males and 16 females, aged from 17 to 68 years with suspected MIA underwent 64-slice spiral CTA with slice thickness of 0.625mm. The data of all patients were reconstructed with multiplanar reconstruction (MPR, 3-dimensional shade surface display (3-SSD, volume rendering (VR and maximum intensity projection (MIP. The clinical diagnostic value was evaluated with the results of surgery or interventional embolization therapy. Results  A total of 61 aneurysms were detected by 64-slice spiral CTA in 25 patients, among them 17 patients were with 2 aneurysms, 6 patients with 3 aneurysms, 1 patient with 4 aneurysms and 1 patient with 5 aneurysms. The 64-slice spiral CTA could not only clearly demonstrate MIA, but also the size, neck, axis point and parent artery of each aneurysm, and the spatial relationship between aneurysm and the adjacent vessels and bone structures. Twenty-one patients underwent microsurgery and four underwent embolization, the location, size and shape of aneurysm and its spatial relationship with adjacent structures were in accordance with the findings of 64-slice spiral CTA. Conclusion  The 64-slice spiral CTA could be used as the first choice in the diagnosis of MIA for its high accuracy, and may be an important adjunct to digital subtraction angiography (DSA in MIA treatment.

  9. Long-Term Clinical Impact of Coronary CT Angiography in Patients With Recent Acute-Onset Chest Pain

    DEFF Research Database (Denmark)

    Linde, Jesper J; Hove, Jens D; Sørgaard, Mathias

    2015-01-01

    was a composite of cardiac death, myocardial infarction (MI), hospitalization for unstable angina pectoris (UAP), late symptom-driven revascularizations, and readmission for chest pain. RESULTS: We randomized 299 patients to coronary CTA-guided strategy and 301 to standard care. After inclusion, 24 patients......OBJECTIVES: The aim of the CATCH (CArdiac cT in the treatment of acute CHest pain) trial was to investigate the long-term clinical impact of a coronary computed tomographic angiography (CTA)-guided treatment strategy in patients with recent acute-onset chest pain compared to standard care....... BACKGROUND: The prognostic implications of a coronary CTA-guided treatment strategy have not been compared in a randomized fashion to standard care in patients referred for acute-onset chest pain. METHODS: Patients with acute chest pain but normal electrocardiograms and troponin values were randomized...

  10. Right cerebellar infarction due to ipsilateral neck-rotation-induced right vertebral artery compression and occlusion, demonstrated by CT angiography

    Directory of Open Access Journals (Sweden)

    Rongli Wu, MD

    2015-01-01

    Full Text Available Rotation-induced vertebral artery compression and occlusion with the outcome of cerebellar infarction (as opposed to the outcome of transient ischemia from hemodynamic insufficiency, known as bow hunter's stroke is extremely rare. We report a 40-year-old male who suffered from ipsilateral neck-rotation-induced right vertebral artery compression and occlusion that resulted in right cerebellar infarction. In most reported cases, the rotation-compressed vertebral artery is located at the C1–2 level; however, our patient's compressed artery was located at the C6–7 level as demonstrated clearly by 3-dimensional CT angiography. This case report is based on a literature review and an investigation of the likely factors of this specific incident via the patient's personal details, clinical course, and diagnostic images.

  11. Anterior communicating artery aneurysms and an unusual variations of anterior comminicating artery detected by 3-D CT angiography

    Directory of Open Access Journals (Sweden)

    Hasan Emre Aydın

    2014-04-01

    Full Text Available Aneurysmal subarachnoid haemorrhage which has a serious mortality and morbitity ratio, occurs approximately 10/100 000 population per year and it is usally caused by rupture of a cerebral artery aneurysm. Aneurysms are classified sacculer, fusiform or dissecan by morphlogical description. Vascular congenital anomalies of the cerebral vessels contribute to saccular aneurysm formation by increasing hemodynamic stress on the vessel wall. Although anterior communicating artery (ACoA is the most seen site of vascular anomalies associated with aneurysmal formation, the agenesis of the anterior commmunicating artery is very rare. Here, we present unusual anatomical variations of ACoA detected by three-dimensional CT angiography after subarachnoid hemorrhage.

  12. Comparison of ultrafast-CT, MRA, and angiography for detection of coronary artery bypass graft patency; Vergleich von ultraschneller Computertomographie, Magnetresonanzangiographie und selektiver Angiographie zum Nachweis der Durchgaengigkeit koronarer Bypasses

    Energy Technology Data Exchange (ETDEWEB)

    Smekal, A. von [Inst. fuer Radiologische Diagnostik, Klinikum Grosshadern, Muenchen Univ. (Germany); Knez, A. [Medizinische Klinik 1, Klinikum Grosshadern, Muenchen Univ. (Germany); Seelos, K.C. [Inst. fuer Radiologische Diagnostik, Klinikum Grosshadern, Muenchen Univ. (Germany); Haberl, R. [Medizinische Klinik 1, Klinikum Grosshadern, Muenchen Univ. (Germany); Spiegl, F. [Inst. fuer Radiologische Diagnostik, Klinikum Grosshadern, Muenchen Univ. (Germany); Reichart, B. [Herzchirurgische Klinik, Klinikum Grosshadern, Muenchen Univ. (Germany); Steinbeck, G. [Medizinische Klinik 1, Klinikum Grosshadern, Muenchen Univ. (Germany); Reiser, M. [Inst. fuer Radiologische Diagnostik, Klinikum Grosshadern, Muenchen Univ. (Germany)

    1997-03-01

    Purpose: Validation of ultrafast-CT and MR-angiography (MRA) in comparison with angiography for detection of early postsurgical arterial and venous coronary artery bypass graft (CABG) patency. Methods: 21 patients with a total of 55 CABG (34 venous and 21 arterial) were studied with angiography, ultrafast-CT (EBT), and MRA. Results: With EBT, patency of 43/45 angiographically patent CABG could be correctly assessed (sensitivity: 96%). With MRA 26 CABG (17 venous and 9 arterial) were identified as patent (sensitivity: 67%). It was not possible to quantify proximal stenosis of three grafts (>40%) and to evaluate the distal bypass anastomosis with both EBT and MRA. Conclusions: Ultrafast-CT is a promising minimal invasive screening method for the evaluation of venous and arterial CABG patency. The diagnostic significance of MRA is remarkably reduced. (orig.) [Deutsch] Ziel: Validierung von ultraschneller Computertomographie und Magnetresonanzangiographie im Vergleich zur selektiven Angiographie fuer die fruehe postoperative Beurteilung der Durchgaengigkeit venoeser und arterieller koronarer Bypasses. Methoden: Vergleichend mit der Angiographie wurden 21 Patienten mit insgesamt 55 Bypasses (34 venoese, 21 arterielle) mittels ultraschneller Computertomographie (Electron Beam Tomography=EBT) und Magnetresonanzangiographie (MRT) untersucht. Ergebnisse: Mit EBT konnten 43 von 45 angiographisch offenen Bypasses korrekt als durchgaengig nachgewiesen werden (Sensitivitaet 96%). Durch MRA wurden 26 von 39 offenen Bypasses (17 venoes und 9 arteriell) eindeutig als durchgaengig beurteilt. Dies entspricht einer Sensitivitaet von 67%. Proximale Stenosen (>40%) von drei Bypasses konnten weder mit EBT noch durch MRA quantifiziert werden. Eine Beurteilung der Insertionsstelle der Bypasses auf das Nativgefaess war mit beiden Verfahren nicht moeglich. Schlussfolgerung: Die ultraschnelle Computertomographie ist ein vielversprechendes, wenig belastendes Screeningverfahren fuer die

  13. Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stenzel, Fabian; Rief, Matthias; Zimmermann, Elke; Greupner, Johannes; Richter, Felicitas; Dewey, Marc [Charite - Universitaetsmedizin Berlin, Department of Radiology, Berlin (Germany)

    2014-06-15

    Comparison of bolus tracking with a fixed threshold versus a manual fast start for coronary CT angiography. We retrospectively analysed 320-row coronary CT angiography of 50 patients with suspected or known coronary artery disease. Twenty-five examinations were initiated by a bolus tracking method (group 1), 25 examinations with a manual fast surestart (group 2). Mean attenuation values in the ascending aorta were 519 ± 111 Hounsfield units (HU) in group 1 and 476 ± 65 HU in group 2 (p = 0.10). Assessable vessel lengths were 171 ± 44 mm vs 172 ± 29 mm for the right coronary artery (p = 0.91), 11 ± 4 mm vs 12 ± 4 mm for the left main (p = 0.9), 163 ± 28 mm vs 151 ± 26 mm for the left anterior descending coronary artery (p = 0.11) and 125 ± 41 mm vs 110 ± 37 mm for the left circumflex coronary artery (p = 0.18). Image quality for all coronary arteries was not significantly different between the groups (p > 0.41). The attenuation ratio between the left and right ventricle was 2.8 ± 0.7 vs 3.6 ± 1.0 (p = 0.003). Significantly less contrast agent was used in group 2 (64 ± 6 ml vs 80 ± 0 ml; p < 0.001). Bolus tracking with a fixed threshold and with a manual fast start are both suitable methods; the fast start allowed a reduction of contrast agent volumes. (orig.)

  14. The utility of perfusion CT and CT angiography on early diagnosis and the management of vasospasm after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Samira Zabihyan

    2015-01-01

    Full Text Available Subarachnoid hemorrhage is one of the most important and dangerous neurologic emergencies worldwide. It is characterized by a sudden and severe headache caused most commonly by the rupture of intracranial aneurysm. Cerebral vasospasm is the most important cause of disability and death in whom survived from the first event. Early diagnosis and management of cerebral vasospasm could prevent and reduce its morbidity and mortality. Thus, an ideal technique must be able to detect the vasospasm before the occurrence of neurological deficits. Perfusion computed tomography could assess vascularity of brain including cerebral blood flow, cerebral blood volume, time to peak and mean transit time. For this application, perfusion computed tomography and computed tomography angiography techniques offer significant advantages and can result in early diagnosis of vasospasm. In this review, we discuss the utility of these two techniques and their safety in the diagnosis and the management of vasospasm following subarachnoid hemorrhage.

  15. Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Han, Ari; Yoon, Dae Young; Chang, Suk Ki (Dept. of Radiology, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)), email: evee0914@chollian.net; Lim, Kyoung Ja (Dept. of Radiology, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of); Dept. of Radiology, Kangwon National Univ. College of Medicine, Chuncheon, Kangwon-do (Korea, Republic of)); Cho, Byung-Moon (Dept. of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)); Shin, Yoon Cheol (Dept. of Thoracic Surgery, Kangdong Seong-Sim Hospital, Hallym Univ. College of Medicine, Seoul (Korea, Republic of)); Kim, Sam Soo (Dept. of Radiology, Kangwon National Univ. College of Medicine, Chuncheon, Kangwon-do (Korea, Republic of)); Kim, Keon Ha (Dept. of Radiology, Samsung Medical Center, Sungkyunkwan Univ. College of Medicine, Seoul (Korea, Republic of))

    2011-10-15

    Background Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases. Purpose To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis. Material and Methods One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-com A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CTA volume-rendered images. The CTA results were then compared with findings on the corresponding DSA images (reference standard). Results The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CTA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%. Conclusion CTA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments

  16. Electrocardiographically triggered CT angiography of the whole aorta and coronary arteries with high-pitch dual-source CT

    Institute of Scientific and Technical Information of China (English)

    张楠

    2013-01-01

    Objective To investigate the feasibility of comprehensive assessment of the whole aorta and coronary arteries(CA)simultaneously with high-pitch128-slice dualsource CT ECG-gated FLASH protocol.Methods A totalof 48 consecutive patients with suspected aortic diseases

  17. Data of evolutionary structure change: 1CCTA-3D0NA [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available A 1CCTA VHWNT-KYGDF ...1CCTA-3D0NA 1CCT 3D0N A A ------WGYGKHNGPEHWHKDFPIAKGERQSPVDIDTHT...SIKEKGKQTRFTNFDLLSLLPPSWDYWTYPGSLTVPPLLESVTWIVLKQPINISSQQLAKFRSLLCTAEGEAAAFLVSNHRPPQPLKGRKVRASFH 0 1CCT...ure>EEEEE-GG Hure> ATOM 933 CA VAL A 121 -11.826 4.712 15

  18. Data of evolutionary structure change: 1CCTA-3D0NB [Confc[Archive

    Lifescience Database Archive (English)

    Full Text Available ID> A 1CCTA VHWNT-KYGDF ...1CCTA-3D0NB 1CCT 3D0N A B ------WGYGKHNGPEHWHKDFPIAKGERQSPVDIDTHT...SIKEKGKQTRFTNFDLLSLLPPSWDYWTYPGSLTVPPLLESVTWIVLKQPINISSQQLAKFRSLLCTAEGEAAAFLVSNHRPPQPLKGRKVRASFH 0 1CCTEEEEE-GG Hure> ATOM 933 CA VAL A 121 -11.826 4.712 15.895

  19. Comparison of the Effect of Iterative Reconstruction versus Filtered Back Projection on Cardiac CT Postprocessing

    NARCIS (Netherlands)

    Spears, J. Reid; Schoepf, U. Joseph; Henzler, Thomas; Joshi, Gayatri; Moscariello, Antonio; Vliegenthart, Rozemarijn; Cho, Young Jun; Apfaltrer, Paul; Rowe, Garrett; Weininger, Markus; Ebersberger, Ullrich

    2014-01-01

    Rationale and Objectives: To investigate the impact of iterative reconstruction in image space (IRIS) on image noise, image quality (10), and postprocessing at coronary computed tomography angiography (cCTA) compared to traditional filtered back-projection (FBP). Materials and Methods: The cCTA resu

  20. Comparison of the Effect of Iterative Reconstruction versus Filtered Back Projection on Cardiac CT Postprocessing

    NARCIS (Netherlands)

    Spears, J. Reid; Schoepf, U. Joseph; Henzler, Thomas; Joshi, Gayatri; Moscariello, Antonio; Vliegenthart, Rozemarijn; Cho, Young Jun; Apfaltrer, Paul; Rowe, Garrett; Weininger, Markus; Ebersberger, Ullrich

    2014-01-01

    Rationale and Objectives: To investigate the impact of iterative reconstruction in image space (IRIS) on image noise, image quality (10), and postprocessing at coronary computed tomography angiography (cCTA) compared to traditional filtered back-projection (FBP). Materials and Methods: The cCTA resu

  1. Prognostic and accuracy data of multidetector CT coronary angiography in an established clinical service

    Energy Technology Data Exchange (ETDEWEB)

    Van Lingen, R. [Department of Cardiology, Derriford Hospital, Plymouth, Devon (United Kingdom)], E-mail: Robin.vanLingen@rcht.cornwall.nhs.uk; Kakani, N.; Veitch, A.; Manghat, N.E.; Roobottom, C.A. [Department of Clinical Radiology, Derriford Hospital, Plymouth, Devon (United Kingdom); Morgan-Hughes, G.J. [Department of Cardiology, Derriford Hospital, Plymouth, Devon (United Kingdom)

    2009-06-15

    Aim: To assess the accuracy of clinical coronary computed tomography angiography (CTA) data compared to invasive coronary angiography, and to determine the prognostic value of a negative coronary CTA examination in symptomatic, intermediate-risk patients. Methods: Thirty-seven months of coronary CTA data were audited. Seventy-eight patients were identified who had undergone coronary CTA followed by invasive coronary angiography (ICA) to determine the accuracy of CTA versus ICA. One hundred and seventy-eight patients were identified who had a 'negative' coronary CTA to enable evaluation of the prognostic value of a negative CTA examination. Results: Of the 78 patients in the accuracy analysis group there were 43 true-negative, two false-negative, 26 true-positive, and seven false-positive results producing a sensitivity of 92.9%, specificity of 86%, negative predictive value of 95.6%, and positive predictive value of 78.8%. The 178 patients who had a negative coronary CTA examination were followed up for a mean of 366 days and were all alive (0% mortality) with no episodes of myocardial infarction or unstable angina; two patients underwent elective revascularization procedures (1.1%). Conclusion: According to medium-term analysis, the accuracy of the clinical coronary CTA programme is in line with published trial data, producing excellent sensitivity and negative predictive values. The finding of a negative coronary CTA in symptomatic, intermediate-risk patients appears to confer a good prognosis, at mean follow-up of 1 year, with no deaths or episodes of myocardial infarction or unstable angina. This suggests that the prognostic value of a negative coronary CTA may be similar to that conferred by negative myocardial perfusion scintigraphy or stress echocardiography.

  2. Development and Validation of Intracranial Thrombus Segmentation on CT Angiography in Patients with Acute Ischemic Stroke

    NARCIS (Netherlands)

    Santos, E.M.M.; Marquering, H.A.; Berkhemer, O.A.; Van Zwam, W.H.; Van der Lugt, A.; Majoie, C.B.; Niessen, W.J.

    2014-01-01

    Background and Purpose: Thrombus characterization is increasingly considered important in predicting treatment success for patients with acute ischemic stroke. The lack of intensity contrast between thrombus and surrounding tissue in CT images makes manual delineation a difficult and time consuming

  3. Development and validation of intracranial thrombus segmentation on CT angiography in patients with acute ischemic stroke

    NARCIS (Netherlands)

    Santos, E.M.; Marquering, H.A.; Berkhemer, O.A.; Zwam, W.H. van; Lugt, A. van der; Majoie, C.B.; Niessen, W.J.; Dijk, E.J. van

    2014-01-01

    BACKGROUND AND PURPOSE: Thrombus characterization is increasingly considered important in predicting treatment success for patients with acute ischemic stroke. The lack of intensity contrast between thrombus and surrounding tissue in CT images makes manual delineation a difficult and time consuming

  4. CT pulmonary angiography of adult pulmonary vascular diseases: Technical considerations and interpretive pitfalls.

    Science.gov (United States)

    Taslakian, Bedros; Latson, Larry A; Truong, Mylene T; Aaltonen, Eric; Shiau, Maria C; Girvin, Francis; Alpert, Jeffrey B; Wickstrom, Maj; Ko, Jane P

    2016-11-01

    Computed tomography pulmonary angiography (CTPA) has become the primary imaging modality for evaluating the pulmonary arteries. Although pulmonary embolism is the primary indication for CTPA, various pulmonary vascular abnormalities can be detected in adults. Knowledge of these disease entities and understanding technical pitfalls that can occur when performing CTPA are essential to enable accurate diagnosis and allow timely management. This review will cover a spectrum of acquired abnormalities including pulmonary embolism due to thrombus and foreign bodies, primary and metastatic tumor involving the pulmonary arteries, pulmonary hypertension, as well as pulmonary artery aneurysms and stenoses. Additionally, methods to overcome technical pitfalls and interventional treatment options will be addressed.

  5. Automatic segmentation and quantification of the cardiac structures from non-contrast-enhanced cardiac CT scans

    Science.gov (United States)

    Shahzad, Rahil; Bos, Daniel; Budde, Ricardo P. J.; Pellikaan, Karlijn; Niessen, Wiro J.; van der Lugt, Aad; van Walsum, Theo

    2017-05-01

    Early structural changes to the heart, including the chambers and the coronary arteries, provide important information on pre-clinical heart disease like cardiac failure. Currently, contrast-enhanced cardiac computed tomography angiography (CCTA) is the preferred modality for the visualization of the cardiac chambers and the coronaries. In clinical practice not every patient undergoes a CCTA scan; many patients receive only a non-contrast-enhanced calcium scoring CT scan (CTCS), which has less radiation dose and does not require the administration of contrast agent. Quantifying cardiac structures in such images is challenging, as they lack the contrast present in CCTA scans. Such quantification would however be relevant, as it enables population based studies with only a CTCS scan. The purpose of this work is therefore to investigate the feasibility of automatic segmentation and quantification of cardiac structures viz whole heart, left atrium, left ventricle, right atrium, right ventricle and aortic root from CTCS scans. A fully automatic multi-atlas-based segmentation approach is used to segment the cardiac structures. Results show that the segmentation overlap between the automatic method and that of the reference standard have a Dice similarity coefficient of 0.91 on average for the cardiac chambers. The mean surface-to-surface distance error over all the cardiac structures is 1.4+/- 1.7 mm. The automatically obtained cardiac chamber volumes using the CTCS scans have an excellent correlation when compared to the volumes in corresponding CCTA scans, a Pearson correlation coefficient (R) of 0.95 is obtained. Our fully automatic method enables large-scale assessment of cardiac structures on non-contrast-enhanced CT scans.

  6. Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Zhaoping; Wang, Ximing; Duan, Yanhua; Wu, Lebin; Wu, Dawei; Chao, Baoting; Liu, Cheng; Xu, Zhuodong [Shandong University, Shandong Medical Imaging Research Institute, Jinan, Shandong (China); Li, Hongxin; Liang, Fei [Shandong Provincial Hospital, Department of Cardiovascular Surgery, Jinan, Shandong (China); Xu, Jian; Chen, Jiuhong [Siemens. Ltd. China, CT Research Collaboration, Beijing (China)

    2010-10-15

    To explore the clinical value of low-dose prospective ECG-triggering dual-source CT (DSCT) angiography in infants and children with complex congenital heart disease (CHD) compared with transthoracic echocardiography (TTE). Thirty-five patients (mean age: 16 months, range: 2 months to 6 years; male 15; mean weight: 12 kg) underwent low-dose prospective ECG-triggering DSCT angiography and TTE. Surgeries were performed in 29 patients, and conventional cardiac angiography (CCA) was performed in 8 patients. The accuracy was calculated based on the surgical and/or CCA findings. The overall imaging quality was evaluated on a five-point scale. A total of 146 separate cardiovascular deformities were confirmed. DSCT missed three atrial septal defects and a patent ductus arteriosus. The accuracy of DSCT angiography and TTE was 97.3% (142/146) and 92.5% (135/146), respectively. Overall test parameters for DSCT angiography and TTE were similar (sensitivity, 97.3% vs 92.5%; specificity, 99.8% vs 99.8%). The average subjective image quality score was 4.3 {+-} 0.7. The mean effective dose was 0.38 {+-} 0.09 mSv. Prospective ECG-triggering DSCT angiography with a very low effective radiation dose allows the accurate diagnosis of anomalies in infants and children with complex CHD compared with TTE. It has great promise to become a commonly used second-line technique for complex CHD. (orig.)

  7. Fusion of CT Angiography or MR Angiography with Unenhanced CBCT and Fluoroscopy Guidance in Endovascular Treatments of Aorto-Iliac Steno-Occlusion: Technical Note on a Preliminary Experience

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria; Duka, Ejona [University of Insubria, Interventional Radiology, Department of Radiology (Italy); Radaelli, Alessandro [Philips Healthcare (Netherlands); Rivolta, Nicola; Piffaretti, Gabriele [University of Insubria, Vascular Surgery Department (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [University of Insubria, Interventional Radiology, Department of Radiology (Italy)

    2016-01-15

    AimTo evaluate the feasibility of image fusion (IF) of pre-procedural arterial-phase CT angiography or MR angiography with intra-procedural fluoroscopy for road-mapping in endovascular treatment of aorto-iliac steno-occlusive disease.Materials and MethodsBetween September and November, 2014, we prospectively evaluated 5 patients with chronic aorto-iliac steno-occlusive disease, who underwent endovascular treatment in the angiography suite. Fusion image road-mapping was performed using angiographic phase CT images or MR images acquired before and intra-procedural unenhanced cone-beam CT. Radiation dose of the procedure, volume of intra-procedural iodinated contrast medium, fluoroscopy time, and overall procedural time were recorded. Reasons for potential fusion imaging inaccuracies were also evaluated.ResultsImage co-registration and fusion guidance were feasible in all procedures. Mean radiation dose of the procedure was 60.21 Gycm2 (range 55.02–63.75 Gycm2). The mean total procedure time was 32.2 min (range 27–38 min). The mean fluoroscopy time was 12 min and 3 s. The mean procedural iodinated contrast material dose was 24 mL (range 20–40 mL).ConclusionsIF gives Interventional Radiologists the opportunity to use new technologies in order to improve outcomes with a significant reduction of contrast media administration.

  8. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Chu, W.C.W.; Lam, W.W.M. [Department of Diagnostic Radiology and Organ Imaging, Chinese Univ. of Hong Kong, Shatin (China); Mok, G.C.F.; Yam, M.; Sung, R.Y.T. [Dept. of Pediatrics, Chinese Univ. of Hong Kong, Shatin (China)

    2006-11-15

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size.

  9. The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography

    Directory of Open Access Journals (Sweden)

    Toon Van Cauteren

    2017-01-01

    Full Text Available Objectives. To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR techniques on the iodine dose in coronary CTA. Methods. Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR, and contrast-to-noise ratio (CNR in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann–Whitney U test and Chi-square analysis. Results. Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11, except for streak artifacts (p=0.02 which were considered to be more severe, although acceptable, with the 80 kVp protocol. Conclusions. Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.

  10. Contrast material and radiation dose reduction strategy for triple-rule-out cardiac CT angiography: feasibility study of non-ECG-gated low kVp scan of the whole chest following coronary CT angiography.

    Science.gov (United States)

    Kidoh, Masafumi; Nakaura, Takeshi; Nakamura, Shinichi; Namimoto, Tomohiro; Nozaki, Toshimitsu; Sakaino, Naritsugu; Harada, Kazunori; Yamashita, Yasuyuki

    2014-12-01

    Dedicated coronary computed tomography (CT) scan has been proven to be an accurate diagnostic modality in evaluating coronary artery disease. A second phase scan starting immediately after the coronary CT scan might enable visualization of the different vascular territories of the entire chest. To investigate the feasibility of a contrast material and radiation dose reduction triple-rule-out (TRO) CT angiography (CTA) protocol with serial non-ECG-gated low kVp scan of the whole chest, which utilizes a recirculated contrast agent. Thirty patients were scanned with the new TRO-CTA protocol; after the coronary scan with retrospective ECG-gating, non-ECG-gated whole-chest CTA was performed at 80 kVp to evaluate aortic arch (AAr) and pulmonary trunk (PT). Another 30 patients were scanned by our conventional TRO-CTA protocol at 120 kVp with retrospective ECG-gating. We compared the estimated effective dose (ED), contrast material (CM) dose, contrast-to-noise ratio (CNR) of the ascending aorta (AAo), and the rate of patients who could achieve adequate attenuation of the AAr and PT between the two protocols. The total ED of the new TRO-CTA protocol was 29.6% lower than that of the conventional protocol (P TRO-CTA protocol was significantly lower than in the conventional protocol (60.1 ± 9.6 mL vs. 91.8 ± 22.6 mL, P TRO-CTA protocol than with the conventional protocol (P 0.05). The new TRO-CTA protocol can reduce the total dose of radiation and the contrast dose and yield adequate vascular enhancement compared with the conventional protocol. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  11. Added value of CT perfusion compared to CT angiography in predicting clinical outcomes of stroke patients treated with mechanical thrombectomy

    Energy Technology Data Exchange (ETDEWEB)

    Tsogkas, Ioannis; Knauth, Michael; Schregel, Katharina; Behme, Daniel; Psychogios, Marios Nikos [University Medicine Goettingen, Department of Neuroradiology, Goettingen (Germany); Wasser, Katrin; Maier, Ilko; Liman, Jan [University Medicine Goettingen, Department of Neurology, Goettingen (Germany)

    2016-11-15

    CTP images analyzed with the Alberta stroke program early CT scale (ASPECTS) have been shown to be optimal predictors of clinical outcome. In this study we compared two biomarkers, the cerebral blood volume (CBV)-ASPECTS and the CTA-ASPECTS as predictors of clinical outcome after thrombectomy. Stroke patients with thrombosis of the M1 segment of the middle cerebral artery were included in our study. All patients underwent initial multimodal CT with CTP and CTA on a modern CT scanner. Treatment consisted of full dose intravenous tissue plasminogen activator, when applicable, and mechanical thrombectomy. Three neuroradiologists separately scored CTP and CTA images with the ASPECTS score. Sixty-five patients were included. Median baseline CBV-ASPECTS and CTA-ASPECTS for patients with favourable clinical outcome at follow-up were 8 [interquartile range (IQR) 8-9 and 7-9 respectively]. Patients with poor clinical outcome showed a median baseline CBV-ASPECTS of 6 (IQR 5-8, P < 0.0001) and a median baseline CTA-ASPECTS of 7 (IQR 7-8, P = 0.18). Using CBV-ASPECTS and CTA-ASPECTS raters predicted futile reperfusions in 96 % and 56 % of the cases, respectively. CBV-ASPECTS is a significant predictor of clinical outcome in patients with acute ischemic stroke treated with mechanical thrombectomy. (orig.)

  12. A prospective two-center study on the associations between microalbuminuria, coronary atherosclerosis and long-term clinical outcome in asymptomatic patients with type 2 diabetes mellitus: evaluation by coronary CT angiography.

    Science.gov (United States)

    Kim, Jin-Jin; Hwang, Byung-Hee; Choi, Ik Jun; Choo, Eun-Ho; Lim, Sungmin; Koh, Yoon-Seok; Lee, Jong Min; Kim, Pum-Joon; Seung, Ki-Bae; Lee, Seung-Hwan; Cho, Jae-Hyung; Jung, Jung Im; Chang, Kiyuk

    2015-01-01

    This study assessed the associations between microalbuminuria in asymptomatic patients with type 2 diabetes and the presence, extent, and severity of coronary atherosclerosis, as measured by coronary computed tomography angiography (CCTA), and the long-term clinical outcomes. In total, the study enrolled 284 consecutive eligible asymptomatic patients with type 2 diabetes and without known coronary artery disease (CAD), who then underwent CCTA and 24 h urine albumin measurements. Microalbuminuria was defined as 30-300 mg/day urinary albumin excretion. Obstructive CAD, as measured by CCTA, was defined as maximum intra-luminal stenosis ≥50 %. Patients with and without microalbuminuria were compared in terms of obstructive CAD prevalence, and the extent and severity of coronary atherosclerosis. They were evaluated using the following data: coronary artery calcium score (CACS), atheroma burden obstructive score (ABOS), segment involvement score (SIS) and segment stenosis score (SSS). All-cause mortality within a follow-up period of 5 years was also compared. Compared to patients without microalbuminuria, patients with microalbuminuria were more likely to have obstructive CAD (p = 0.004). Microalbuminuria was associated with higher ABOS (p = 0.010), SIS (p = 0.029), and SSS (p = 0.011), except for CACS (p = 0.058). Multivariable analyses adjusted for conventional cardiovascular risk factors revealed that microalbuminuria was an independent predictor of obstructive CAD [odds ratio 2.255, confidence intervals (CI) 1.121-4.538, p = 0.023] and all-cause mortality (hazard ratio 3.469, CI 1.319-9.121, p = 0.012). In asymptomatic patients with type 2 diabetes, microalbuminuria was associated with increased risk of CAD and poorer clinical outcomes.

  13. Coronary CT Angiography in Coronary Artery Disease: Correlation between Virtual Intravascular Endoscopic Appearances and Left Bifurcation Angulation and Coronary Plaques

    Directory of Open Access Journals (Sweden)

    Zhonghua Sun

    2013-01-01

    Full Text Available The aim of this study is to investigate the relationship between intraluminal appearances of coronary plaques and left coronary bifurcation angle and plaque components using coronary CT virtual intravascular endoscopy (VIE. Fifty patients suspected of coronary artery disease undergoing coronary CT angiography were included in the study. The left bifurcation angle in patients with diseased left coronary artery which was measured as 94.3° ± 16.5 is significantly larger than that in patients with normal left coronary artery, which was measured as 76.5° ± 15.9 (P<0.001. Irregular VIE appearances were found in 10 out of 11 patients with mixed plaques in the left anterior descending (LAD and left circumflex (LCx, while, in 29 patients with calcified plaques in the LAD and LCx, irregular VIE appearances were only noticed in 5 patients. Using 80° as a cut-off value to determine coronary artery disease, smooth VIE appearances were found in 95% of patients (18/19 with left bifurcation angle of less than 80°, while irregular VIE appearances were observed in nearly 50% of patients (15/31 with left bifurcation angle of more than 80°. This preliminary study shows that VIE appearances of the coronary lumen are directly related to the types of plaques.

  14. Widening of coronary sinus in CT pulmonary angiography indicates right ventricular dysfunction in patients with acute pulmonary embolism

    Energy Technology Data Exchange (ETDEWEB)

    Staskiewicz, Grzegorz [Medical University of Lublin, 1. Department of Radiology, Lublin (Poland); Medical University of Lublin, Department of Human Anatomy, Lublin (Poland); Czekajska-Chehab, Elzbieta; Trojanowska, Agnieszka; Drop, Andrzej [Medical University of Lublin, 1. Department of Radiology, Lublin (Poland); Przegalinski, Jerzy; Tomaszewski, Andrzej [Medical University of Lublin, Chair and Department of Cardiology, Lublin (Poland); Torres, Kamil; Torres, Anna [Medical University of Lublin, Department of Human Anatomy, Lublin (Poland); Maciejewski, Ryszard [Medical University of Lublin, Department of Human Anatomy, Lublin (Poland); UITM Rzeszow, Medical Emergency Department, Rzeszow (Poland)

    2010-07-15

    Right ventricular dysfunction (RVD) may occur in the course of acute pulmonary embolism (PE). Patients with RVD need more intensive treatment, and the prognosis is more severe. The aim of this study was to evaluate the usefulness of the measurement of the coronary sinus in the assessment of RVD in patients with acute PE and to compare it with other indicators of RVD. Retrospective assessment of 55 CT pulmonary angiography examinations with signs of acute PE was performed. Pulmonary artery systolic pressure (PASP) was echocardiographically assessed in all patients, and RVD was defined as PASP values greater than 30 mmHg. CT measurements included the size of the heart ventricles, mediastinal vessels and the width of the coronary sinus. Median width of the coronary sinus was 16 mm (range 12-24 mm) in patients with increased PASP and 10 mm (range 7-22 mm) in patients with normal PASP (p = 0.001). Best cut-off value was assessed to be 12.5 mm, with sensitivity 94% and specificity 75%. It was characterised by the largest area under ROC curve (0.82) among analysed parameters. Width of the coronary sinus seems to be a promising parameter for identification of RVD in patients with acute PE. A prospective study should be undertaken to further assess its clinical and prognostic applicability. (orig.)

  15. Coronary CT angiography: IVUS image fusion for quantitative plaque and stenosis analyses

    Science.gov (United States)

    Marquering, Henk A.; Dijkstra, Jouke; Besnehard, Quentin J. A.; Duthé, Julien P. M.; Schuijf, Joanne D.; Bax, Jeroen J.; Reiber, Johan H. C.

    2008-03-01

    Rationale and Objective: Due to the limited temporal and spatial resolution, coronary CT angiographic image quality is not optimal for robust and accurate stenosis quantification, and plaque differentiation and quantification. By combining the high-resolution IVUS images with CT images, a detailed representation of the coronary arteries can be provided in the CT images. Methods: The two vessel data sets are matched using three steps. First, vessel segments are matched using anatomical landmarks. Second, the landmarks are aligned in cross-sectional vessel images. Third, the semi-automatically detected IVUS lumen contours are matched to the CTA data, using manual interaction and automatic registration methods. Results: The IVUS-CTA fusion tool facilitates the unique combined view of the high-resolution IVUS segmentation of the outer vessel wall and lumen-intima transitions on the CT images. The cylindrical projection of the CMPR image decreases the analysis time with 50 percent. The automatic registration of the cross-vessel views decreases the analyses time with 85 percent. Conclusions: The fusion of IVUS images and their segmentation results with coronary CT angiographic images provide a detailed view of the lumen and vessel wall of coronary arteries. The automatic fusion tool makes such a registration feasible for the development and validation of analysis tools.

  16. Coronary dominance and prognosis in patients undergoing coronary computed tomographic angiography: Results from the CONFIRM (COronary CTAngiography EvaluatioN for Clinical Outcomes: An InteRnational Multicenter) registry

    NARCIS (Netherlands)

    C. Gebhard (Catherine); T.A. Fuchs (Tobias A.); J. Stehli (Julia); H. Gransar (Heidi); D.S. Berman (Daniel S.); M.J. Budoff (Matthew); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); M. Gomez (Millie); M. Hadamitzky (Martin); J. Hausleiter (Jörg); N. Hindoyan (Niree); G. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); A.M. Dunning (Allison M.); J.K. Min (James); P.A. Kaufmann (Philipp)

    2015-01-01

    textabstractAims: Coronary computed tomographic angiography (CCTA) has become an important tool for non-invasive diagnosis of coronary artery disease (CAD). Coronary dominance can be assessed by CCTA; however, the predictive value of coronary dominance is controversially discussed. The aim of this s

  17. Coronary dominance and prognosis in patients undergoing coronary computed tomographic angiography: Results from the CONFIRM (COronary CTAngiography EvaluatioN for Clinical Outcomes: An InteRnational Multicenter) registry

    NARCIS (Netherlands)

    C. Gebhard (Catherine); T.A. Fuchs (Tobias A.); J. Stehli (Julia); H. Gransar (Heidi); D.S. Berman (Daniel S.); M.J. Budoff (Matthew); S. Achenbach (Stephan); M. Al-Mallah (Mouaz); D. Andreini (Daniele); F. Cademartiri (Filippo); T.Q. Callister (Tracy); H.-J. Chang (Hyuk-Jae); K. Chinnaiyan (Kavitha); B.J.W. Chow (Benjamin); R.C. Cury (Ricardo); A. Delago (Augustin); M. Gomez (Millie); M. Hadamitzky (Martin); J. Hausleiter (Jörg); N. Hindoyan (Niree); G. Feuchtner (Gudrun); Y.-J. Kim (Yong-Jin); J. Leipsic (Jonathon); F.Y. Lin (Fay); E. Maffei (Erica); G. Pontone (Gianluca); G.L. Raff (Gilbert); L.J. Shaw (Leslee); T.C. Villines (Todd); A.M. Dunning (Allison M.); J.K. Min (James); P.A. Kaufmann (Philipp)

    2015-01-01

    textabstractAims: Coronary computed tomographic angiography (CCTA) has become an important tool for non-invasive diagnosis of coronary artery disease (CAD). Coronary dominance can be assessed by CCTA; however, the predictive value of coronary dominance is controversially discussed. The aim of this s</