WorldWideScience

Sample records for coupled plasma sector

  1. Inductively Coupled Plasma: Fundamental Particle Investigations with Laser Ablation and Applications in Magnetic Sector Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Saetveit, Nathan Joe [Iowa State Univ., Ames, IA (United States)

    2008-01-01

    Particle size effects and elemental fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are investigated with nanosecond and femtosecond laser ablation, differential mobility analysis, and magnetic sector ICP-MS. Laser pulse width was found to have a significant influence on the LA particle size distribution and the elemental composition of the aerosol and thus fractionation. Emission from individual particles from solution nebulization, glass, and a pressed powder pellet are observed with high speed digital photography. The presence of intact particles in an ICP is shown to be a likely source of fractionation. A technique for the online detection of stimulated elemental release from neural tissue using magnetic sector ICP-MS is described. Detection limits of 1 μg L-1 or better were found for P, Mn, Fe, Cu, and Zn in a 60 μL injection in a physiological saline matrix.

  2. Inductively Coupled Plasma: Fundamental Particle Investigations with Laser Ablation and Applications in Magnetic Sector Mass Spectrometry

    International Nuclear Information System (INIS)

    Nathan Joe Saetveit

    2008-01-01

    Particle size effects and elemental fractionation in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) are investigated with nanosecond and femtosecond laser ablation, differential mobility analysis, and magnetic sector ICP-MS. Laser pulse width was found to have a significant influence on the LA particle size distribution and the elemental composition of the aerosol and thus fractionation. Emission from individual particles from solution nebulization, glass, and a pressed powder pellet are observed with high speed digital photography. The presence of intact particles in an ICP is shown to be a likely source of fractionation. A technique for the online detection of stimulated elemental release from neural tissue using magnetic sector ICP-MS is described. Detection limits of 1 (micro)g L -1 or better were found for P, Mn, Fe, Cu, and Zn in a 60 (micro)L injection in a physiological saline matrix

  3. Comparison of methods for the determination of total selenium in plasma by magnetic sector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Featherstone, Alison M.; Townsend, Ashley T.; Jacobson, Glenn A.; Peterson, Gregory M.

    2004-01-01

    Three sample preparation methods (dilution, microwave digestion and ethanol addition) were evaluated for the determination of Se in human plasma using magnetic sector inductively coupled plasma mass spectrometry (ICP-MS). A number of instrumental parameters were also considered, namely the choice of internal standard (Sc, Rh, In) and pre-defined spectral resolution (m/Δm ∼300 (low resolution, LR) and ∼7500 (high resolution, HR)). The isotopes 77 Se and 82 Se were selected for analysis avoiding the major and unresolvable Ar dimer interferences associated with other Se isotopes. Ethanol addition was found to be the most suitable and reliable sample preparation method. The optimum ethanol concentration for a 1+9 dilution of the plasma sample was 0.5% (v/v). Indium or Sc were selected over Rh as internal standards as Seronorm TM Level 1 target values were achieved at lower concentrations of ethanol modifier. Representative ICP-MS detection limits for this method using 77 Se(HR) and 82 Se(HR), were 0.1 and 0.2 μg l -1 . Accurate analysis of Se in Seronorm TM Level 1 (MI0181) was found using either 77 Se or 82 Se and HR (86±5 and 83±5 μg l -1 respectively, n=5, In internal standard, target value=83±6 μg l -1 ). Although offering improved precision (e.g. 82 Se LR: 0-3% versus HR: 1-6%), accurate results were only obtained with LR for the Seronorm TM Level 1 sample when using 82 Se (86±1 μg l -1 ). The major 40 Ar 37 Cl interference precluded accurate Se analysis using 77 Se and LR for all samples considered. Reliable Se concentrations were only found for a 'real' pooled sample when using 82 Se(HR), in part a result of non-negligible and unresolved 81 Br 1 H interference when using LR. Consistently elevated Se concentrations were found under all conditions when Seronorm TM Level 2 (NO0371) was analysed. These results were confirmed by independent GF-AAS analysis. Magnetic sector ICP-MS with 82 Se(HR), in combination with the ethanol addition sample preparation

  4. Determination of total chlorine and bromine in solid wastes by sintering and inductively coupled plasma-sector field mass spectrometry

    International Nuclear Information System (INIS)

    Osterlund, Helene; Rodushkin, Ilia; Ylinenjaervi, Karin; Baxter, Douglas C.

    2009-01-01

    A sample preparation method based on sintering, followed by analysis by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) for the simultaneous determination of chloride and bromide in diverse and mixed solid wastes, has been evaluated. Samples and reference materials of known composition were mixed with a sintering agent containing Na 2 CO 3 and ZnO and placed in an oven at 560 deg. C for 1 h. After cooling, the residues were leached with water prior to a cation-exchange assisted clean-up. Alternatively, a simple microwave-assisted digestion using only nitric acid was applied for comparison. Thereafter the samples were prepared for quantitative analysis by ICP-SFMS. The sintering method was evaluated by analysis of certified reference materials (CRMs) and by comparison with US EPA Method 5050 and ion chromatography with good agreement. Median RSDs for the sintering method were determined to 10% for both chlorine and bromine, and median recovery to 96% and 97%, respectively. Limits of detection (LODs) were 200 mg/kg for chlorine and 20 mg/kg for bromine. It was concluded that the sintering method is suitable for chlorine and bromine determination in several matrices like sewage sludge, plastics, and edible waste, as well as for waste mixtures. The sintering method was also applied for determination of other elements present in anionic forms, such as sulfur, arsenic, selenium and iodine

  5. Measurement of airborne gunshot particles in a ballistics laboratory by sector field inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Diaz, Ernesto; Sarkis, Jorge E Souza; Viebig, Sônia; Saldiva, Paulo

    2012-01-10

    The present study aimed determines lead (Pb), antimony (Sb) and barium (Ba) as the major elements present in GSR in the environmental air of the Ballistics Laboratory of the São Paulo Criminalistics Institute (I.C.-S.P.), São Paulo, SP, Brazil. Micro environmental monitors (mini samplers) were located at selected places. The PM(2.5) fraction of this airborne was collected in, previously weighted filters, and analyzed by sector field inductively coupled plasma mass spectrometer (SF-HR-ICP-MS). The higher values of the airborne lead, antimony and barium, were found at the firing range (lead (Pb): 58.9 μg/m(3); barium (Ba): 6.9 μg/m(3); antimony (Sb): 7.3 μg/m(3)). The mean value of the airborne in this room during 6 monitored days was Pb: 23.1 μg/m(3); Ba: 2.2 μg/m(3); Sb: 1.5 μg/m(3). In the water tank room, the air did not show levels above the limits of concern. In general the airborne lead changed from day to day, but the barium and antimony remained constant. Despite of that, the obtained values suggest that the workers may be exposed to airborne lead concentration that can result in an unhealthy environment and could increase the risk of chronic intoxication. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Evaluating the accuracy of uranium isotope amount ratio measurements performed by a quadrupole and a multi-collector magnetic sector inductively coupled plasma mass spectrometers for nuclear safeguards

    International Nuclear Information System (INIS)

    Pereira de Oliveira, O. Jr.; Sarkis, J.E.S.; Ponzevera, E.; Alonso, A.; De Bolle, W.; Quetel, C.

    2008-01-01

    The n(U 235 )/n(U 238 ) isotope amount ratio in a set of samples was measured using two modern analytical techniques: quadrupole inductively coupled plasma mass spectrometry (ICP-QMS) and multi-collector magnetic sector inductively coupled plasma mass spectrometry (MC-ICPMS). The measured ratios were compared to the certified ratios provided by the high accuracy gas source mass spectrometry (GSMS). The components of the uncertainty were identified and their contribution to the combined standard uncertainty was estimated using the recommendations of the ISO-GUM guide. The values of the measurement uncertainty and bias were determined and then compared to the International Target Values for Measurement Uncertainties in Safeguarding Nuclear Materials. It appears that only the measurements performed by MC-ICPMS can meet the stringent requirements of international nuclear safeguards. (authors)

  7. Trace amounts of rare earth elements in high purity samarium oxide by sector field inductively coupled plasma mass spectrometry after separation by HPLC

    Energy Technology Data Exchange (ETDEWEB)

    Pedreira, W.R. [Instituto de Geociencias, Universidade de Brasilia (UnB), 70910-900 Brasilia, DF (Brazil) and Fundacao Jorge Duprat Figueiredo de Seguranca e Medicina do Trabalho (FUNDACENTRO), 05409-002 Sao Paulo, SP (Brazil)]. E-mail: walter.pedreira@fundacentro.gov.br; Queiroz, C.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), 05508-900 Sao Paulo, SP (Brazil); Abrao, A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), 05508-900 Sao Paulo, SP (Brazil); Rocha, S.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), 05508-900 Sao Paulo, SP (Brazil); Vasconcellos, M.E. de [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), 05508-900 Sao Paulo, SP (Brazil); Boaventura, G.R. [Instituto de Geociencias, Universidade de Brasilia (UnB), 70910-900 Brasilia, DF (Brazil); Pimentel, M.M. [Instituto de Geociencias, Universidade de Brasilia (UnB), 70910-900 Brasilia, DF (Brazil)

    2006-07-20

    Today there is an increasing need for high purity rare earth compounds in various fields, the optical, the electronics, the ceramic, the nuclear and geochemistry. Samarium oxide has special uses in glass, phosphors, lasers and thermoelectric devices. Calcium chloride crystals treated with samarium have been employed in lasers, which produce light beams intense enough to burn metal. In general, the inductively coupled plasma mass spectrometry (ICP-MS) presents some advantages for trace element analysis, due to high sensitivity and resolution, when compared with other analytical techniques such as ICP optical emission spectrometry (ICP-OES). In this work, sector field inductively coupled plasma mass spectrometry was used. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the ICP-MS system using a concentration gradient method. The detection limits with the ICP-MS system were about 0.2 (La) pg mL{sup -1} to 8 (Gd) pg mL{sup -1}. The %R.S.D. of the methods varying between 0.9 and 1.5% for a set of five (n = 5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two high pure samarium oxides samples (IPEN and JMC) was performed. IPEN's material is highly pure (>99.99%) and was successfully analyzed without spectral interference (MO{sup +} and MOH{sup +})

  8. Rapid speciation and determination of vanadium compounds using ion-pair reversed-phase ultra-high-performance liquid chromatography inductively coupled plasma-sector field mass spectrometry.

    Science.gov (United States)

    Kilibarda, Nikola; Afton, Scott E; Harrington, James M; Yan, Fei; Levine, Keith E

    2013-08-23

    Environmental vanadium contamination is a potential concern to public health, as evidenced by its place on the U.S. Environmental Protection Agency Drinking Water Contaminant Candidate List as a priority contaminant. Vanadium toxicity varies significantly between different oxidation states; therefore, it is crucial to be able to monitor the speciation of vanadium in environmental samples. In this study, a novel method is described that utilizes ion-pair reversed-phase ultra-high-performance liquid chromatography with inductively coupled plasma-sector field mass spectrometry (IP-RP-UHPLC-ICP-SFMS) to separate vanadyl and vanadate ions and resolve a major polyatomic spectral interference ((35)Cl(16)O(+)) in less than a minute. Detection limits were obtained in the low ngL(-1) (part per trillion) range with linear calibrations across several orders of magnitude (50ngL(-1)-100μgL(-1)). The mechanism of chromatographic retention was elucidated through investigation of the role of ethylenediaminetetraacetic acid, tetrabutylammonium ion and pH on elution. The optimized method was then applied to the speciation of vanadium in local lake water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Determination of iodine at ppt level in a nitric acid medium by inductively coupled plasma sector field mass spectrometry: influence of the chemical forms

    International Nuclear Information System (INIS)

    Langlois, B.

    2001-01-01

    Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP/SFMS) was used to determine several chemical forms of iodine, at ppt level, in a nitric acid media. Ascorbic acid was added as a reducing agent in order to maintain iodine as iodide. In a preliminary approach, the influence of the chemical form was studied by comparing inorganic iodine (NaI) and organic iodine (CH3I). Different signal responses were observed. With a conventional sample introduction system, sensitivities obtained for iodo-methane could differ by a factor of 5. This was not caused by a problem of atomization or by a change in the ionization efficiency of the iodo-compound into the plasma. The low volatilization temperature of iodo-methane (315.5 K) seemed to be the main explanation of this phenomena. Actually, nebulization resulted in the volatilization of a 2% nitric acid solution containing iodo-methane. As a result, the transport efficiency of iodo-methane between the nebulizer and the torch was approaching 100%. A Direct Injection High Efficiency Nebulizer (DIHEN) allowed us to minimize the behavior difference between the two iodine species, but the sensitivity ratio was inverted and still differed by 20 - 40%. Moreover, the association of a guard electrode and the direct injection system was studied in order to apply these equipments to the determination of iodine. This association allowed us to improve the sensitivity by a factor of 10 and to minimize memory effects, when compared with a conventional system. Further studies indicated that signal responses obtained with different iodine-containing species, except for iodo-methane, were found to be similar. (author)

  10. Method Development for Rapid Analysis of Natural Radioactive Nuclides Using Sector Field Inductively Coupled Plasma Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, J.M.; Ji, Y.Y.; Lee, H.; Park, J.H.; Jang, M.; Chung, K.H.; Kang, M.J.; Choi, G.S. [Korea Atomic Energy Research Institute (Korea, Republic of)

    2014-07-01

    sector field ICP-MS (SPECTRO MS) was used for a rapid determination of radionuclides concentration. For an evaluation of the accuracy and precision of the method, certified reference materials (CRMs) were analyzed using an established process. The analytical results of CRM samples were in agreement with the certified concentration values. Thus, one may conclude that the analytical results derived using fusion and ICP-MS are fairly reliable. Finally, the radioactivity concentration in raw materials (e.g., bauxite, bentonite, ceramic, clay, monazite, and zirconium sand) and by-products (e.g., coal fly and bottom ash) was determined. Document available in abstract form only. (authors)

  11. Stirring Strongly Coupled Plasma

    CERN Document Server

    Fadafan, Kazem Bitaghsir; Rajagopal, Krishna; Wiedemann, Urs Achim

    2009-01-01

    We determine the energy it takes to move a test quark along a circle of radius L with angular frequency w through the strongly coupled plasma of N=4 supersymmetric Yang-Mills (SYM) theory. We find that for most values of L and w the energy deposited by stirring the plasma in this way is governed either by the drag force acting on a test quark moving through the plasma in a straight line with speed v=Lw or by the energy radiated by a quark in circular motion in the absence of any plasma, whichever is larger. There is a continuous crossover from the drag-dominated regime to the radiation-dominated regime. In the crossover regime we find evidence for significant destructive interference between energy loss due to drag and that due to radiation as if in vacuum. The rotating quark thus serves as a model system in which the relative strength of, and interplay between, two different mechanisms of parton energy loss is accessible via a controlled classical gravity calculation. We close by speculating on the implicati...

  12. Method validation for high resolution sector field inductively coupled plasma mass spectrometry determination of the emerging contaminants in the open ocean: Rare earth elements as a case study

    Science.gov (United States)

    Wysocka, Irena; Vassileva, Emilia

    2017-02-01

    Analytical procedure for the determination of fourteen rare earth elements (REEs) in the seawater samples has been developed and validated. The elements (La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, Lu) at ultra-trace level were measured by high resolution sector field inductively coupled plasma mass spectrometry (HR ICP-SFMS) after off-line analytes pre-concentration and matrix separation. The sample pre-treatment was carried out by commercially available automated system seaFAST-pico™, which is a low-pressure ion chromatography technique, based on solid phase extraction principles. Efficient elimination of seawater matrix and up to 50-fold pre-concentration of REEs enabled their accurate and precise quantification at ng L- 1 level. A validation approach in line with the requirements of ISO/IEC 17025 standard and Eurachem guidelines were followed. With this in mind, selectivity, working range, linearity, recovery (from 92% to 102%), repeatability (1%-4%), intermediate precision (2%-6%), limits of detection (0.001-0.08 ng L- 1) were systematically assessed. The total uncertainty associated to each result was estimated and the main sources of uncertainty sorted out. All major contributions to the combined uncertainty of the obtained results were identified and propagated together, following the ISO/GUM guidelines. The relative expanded uncertainty was estimated at range from 10.4% to 11.6% (k = 2). Demonstration of traceability of measurement results was also presented. Due to the low limits of detection, this method enables the determination of ultra-low levels of REEs in the open seawater as well as small variations in their concentrations. The potential of the proposed analytical procedure, based on combination of seaFAST-pico™ for sample preparation and HR ICP-SFMS, was demonstrated by direct analysis of seawater form different regions of the world.

  13. Determination of precise ¹³⁵Cs/¹³⁷Cs ratio in environmental samples using sector field inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Russell, Ben C; Croudace, Ian W; Warwick, Phil E; Milton, J Andy

    2014-09-02

    Recent advances in sector field inductively coupled plasma mass spectrometry (ICP-SFMS) have led to significant sensitivity enhancements that expand the range of radionuclides measurable by ICP-MS. The increasing capability and performance of modern ICP-MS now allows analysis of medium-lived radionuclides previously undertaken using radiometric methods. A new generation ICP-SFMS was configured to achieve sensitivities up to 80,000 counts per second for a 1 ng/L (133)Cs solution, providing a detection limit of 1 pg/L. To extend this approach to environmental samples it has been necessary to develop an effective chemical separation scheme using ultrapure reagents. A procedure incorporating digestion, chemical separation and quantification by ICP-SFMS is presented for detection of the significant fission product radionuclides of cesium ((135)Cs and (137)Cs) at concentrations found in environmental and low level nuclear waste samples. This in turn enables measurement of the (135)Cs/(137)Cs ratio, which varies with the source of nuclear contamination, and can therefore provide a powerful dating and forensic tool compared to radiometric detection of (137)Cs alone. A detection limit in sediment samples of 0.05 ng/kg has been achieved for (135)Cs and (137)Cs, corresponding to 2.0 × 10(-3) and 160 mBq/kg, respectively. The critical issue is ensuring removal of barium to eliminate isobaric interferences arising from (135)Ba and (137)Ba. The ability to reliably measure (135)Cs/(137)Cs using a high specification laboratory ICP-SFMS now enables characterization of waste materials destined for nuclear waste repositories as well as extending options in environmental geochemical and nuclear forensics studies.

  14. Determination of trace sulfur in biodiesel and diesel standard reference materials by isotope dilution sector field inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amais, Renata S. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Long, Stephen E. [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States); Nóbrega, Joaquim A. [Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, São Carlos, SP (Brazil); Christopher, Steven J., E-mail: steven.christopher@nist.gov [Chemical Sciences Division, National Institute of Standards and Technology, Charleston, SC (United States)

    2014-01-02

    Graphical abstract: -- Highlights: •Sulfur mass fractions are measured below 10 mg kg{sup −1} in diesel fuel materials. •SF-ICP-MS resolves molecular interferences, including oxygen and sulfur hydrides. •A detection limit of 0.7 mg kg{sup −1} (in the fuel sample) was obtained. -- Abstract: A method is described for quantification of sulfur at low concentrations on the order of mg kg{sup −1} in biodiesel and diesel fuels using isotope dilution and sector field inductively coupled plasma mass spectrometry (ID-SF-ICP-MS). Closed vessel microwave-assisted digestion was employed using a diluted nitric acid and hydrogen peroxide decomposition medium to reduce sample dilution volumes. Medium resolution mode was employed to eliminate isobaric interferences at {sup 32}S and {sup 34}S related to polyatomic phosphorus and oxygen species, and sulfur hydride species. The method outlined yielded respective limits of detection (LOD) and limits of quantification (LOQ) of 0.7 mg kg{sup −1} S and 2.5 mg kg{sup −1} S (in the sample). The LOD was constrained by instrument background counts at {sup 32}S but was sufficient to facilitate value assignment of total S mass fraction in NIST SRM 2723b Sulfur in Diesel Fuel Oil at 9.06 ± 0.13 mg kg{sup −1}. No statistically significant difference at a 95% confidence level was observed between the measured and certified values for certified reference materials NIST SRM 2773 B100 Biodiesel (Animal-Based), CENAM DRM 272b and NIST SRM 2723a Sulfur in Diesel Fuel Oil, validating method accuracy.

  15. Inductively coupled helium plasma torch

    Science.gov (United States)

    Montaser, Akbar; Chan, Shi-Kit; Van Hoven, Raymond L.

    1989-01-01

    An inductively coupled plasma torch including a base member, a plasma tube and a threaded insert member within the plasma tube for directing the plasma gas in a tangential flow pattern. The design of the torch eliminates the need for a separate coolant gas tube. The torch can be readily assembled and disassembled with a high degree of alignment accuracy.

  16. Physics of Strongly Coupled Plasma

    Energy Technology Data Exchange (ETDEWEB)

    Kraeft, Wolf-Dietrich [Universitat Rostock (Germany)

    2007-07-15

    Strongly coupled plasmas (or non-ideal plasmas) are multi-component charged many-particle systems, in which the mean value of the potential energy of the system is of the same order as or even higher than the mean value of the kinetic energy. The constituents are electrons, ions, atoms and molecules. Dusty (or complex) plasmas contain still mesoscopic (multiply charged) particles. In such systems, the effects of strong coupling (non-ideality) lead to considerable deviations of physical properties from the corresponding properties of ideal plasmas, i.e., of plasmas in which the mean kinetic energy is essentially larger than the mean potential energy. For instance, bound state energies become density dependent and vanish at higher densities (Mott effect) due to the interaction of the pair with the surrounding particles. Non-ideal plasmas are of interest both for general scientific reasons (including, for example, astrophysical questions), and for technical applications such as inertially confined fusion. In spite of great efforts both experimentally and theoretically, satisfactory information on the physical properties of strongly coupled plasmas is not at hand for any temperature and density. For example, the theoretical description of non-ideal plasmas is possible only at low densities/high temperatures and at extremely high densities (high degeneracy). For intermediate degeneracy, however, numerical experiments have to fill the gap. Experiments are difficult in the region of 'warm dense matter'. The monograph tries to present the state of the art concerning both theoretical and experimental attempts. It mainly includes results of the work performed in famous Russian laboratories in recent decades. After outlining basic concepts (chapter 1), the generation of plasmas is considered (chapter 2, chapter 3). Questions of partial (chapter 4) and full ionization (chapter 5) are discussed including Mott transition and Wigner crystallization. Electrical and

  17. High-Performance Method for Determination of Pu Isotopes in Soil and Sediment Samples by Sector Field-Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Wang, Zhongtang; Zheng, Jian; Ni, Youyi; Men, Wu; Tagami, Keiko; Uchida, Shigeo

    2017-02-21

    Plutonium is extensively studied in radioecology (e.g., soil to plant transfer and radiological assessment) and geochemistry (e.g., sediment dating). Here, we reported a new chemical separation method for rapid determination of Pu in soil and sediment samples, based on the following investigations: extraction behaviors of interfering elements (IEs, for inductively coupled plasma mass spectrometry (ICPMS) measurement) on TEVA resin; decontamination of U using TEVA, UTEVA, and DGA resins; and the impact of coprecipitation on Pu determination. The developed method consists of four steps: HNO 3 leaching for Pu release; CaF 2 /LaF 3 coprecipitation for the removal of major metals and U; the proposed TEVA + UTEVA + DGA procedure for the removal of U, Pb, Bi, Tl, Hg, Hf, Pt, and Dy; and ICPMS measurement. The accuracy of this method in determining 239+240 Pu activity and 240 Pu/ 239 Pu and 241 Pu/ 239 Pu isotopic ratios was validated by analyzing five standard reference materials (soil, fresh water sediment, and ocean sediment). This method is characterized by its stable and high Pu recovery (90-97% for soil; 92-98% for sediment) and high decontamination factor of U (1.6 × 10 7 ), which is the highest reported for soil and sediment samples. In addition, the short analytical time of 12 h and the method detection limits, which are the lowest yet reported in literature, of 0.56 μBq g -1 (0.24 fg g -1 ) for 239 Pu, 1.2 μBq g -1 (0.14 fg g -1 ) for 240 Pu, and 0.34 mBq g -1 (0.09 fg g -1 ) for 241 Pu (calculated on the basis of a 1 g soil sample) allow the rapid determination of ultratrace level Pu in soil and sediment samples.

  18. Automated preconcentration of Fe, Zn, Cu, Ni, Cd, Pb, Co, and Mn in seawater with analysis using high-resolution sector field inductively-coupled plasma mass spectrometry.

    Science.gov (United States)

    Rapp, Insa; Schlosser, Christian; Rusiecka, Dagmara; Gledhill, Martha; Achterberg, Eric P

    2017-07-11

    A rapid, automated, high-throughput analytical method capable of simultaneous analysis of multiple elements at trace and ultratrace levels is required to investigate the biogeochemical cycle of trace metals in the ocean. Here we present an analytical approach which uses a commercially available automated preconcentration device (SeaFAST) with accurate volume loading and in-line pH buffering of the sample prior to loading onto a chelating resin (WAKO) and subsequent simultaneous analysis of iron (Fe), zinc (Zn), copper (Cu), nickel (Ni), cadmium (Cd), lead (Pb), cobalt (Co) and manganese (Mn) by high-resolution inductively-coupled plasma mass spectrometry (HR-ICP-MS). Quantification of sample concentration was undertaken using isotope dilution for Fe, Zn, Cu, Ni, Cd and Pb, and standard addition for Co and Mn. The chelating resin is shown to have a high affinity for all analyzed elements, with recoveries between 83 and 100% for all elements, except Mn (60%) and Ni (48%), and showed higher recoveries for Ni, Cd, Pb, Co and Mn in direct comparison to an alternative resin (NOBIAS Chelate-PA1). The reduced recoveries for Ni and Mn using the WAKO resin did not affect the quantification accuracy. A relatively constant retention efficiency on the resin over a broad pH range (pH 5-8) was observed for the trace metals, except for Mn. Mn quantification using standard addition required accurate sample pH adjustment with optimal recoveries at pH 7.5 ± 0.3. UV digestion was necessary to increase recovery of Co and Cu in seawater by 15.6% and 11.4%, respectively, and achieved full break-down of spiked Co-containing vitamin B 12 complexes. Low blank levels and detection limits could be achieved (e.g., 0.029 nmol L -1 for Fe and 0.028 nmol L -1 for Zn) with the use of high purity reagents. Precision and accuracy were assessed using SAFe S, D1, and D2 reference seawaters, and results were in good agreement with available consensus values. The presented method is ideal for

  19. Coupling of Plasmas and Liquids

    Science.gov (United States)

    Lindsay, Alexander David

    Plasma-liquids have exciting applications to several important socioeconomic areas, including agriculture, water treatment, and medicine. To realize their application potential, the basic physical and chemical phenomena of plasma-liquid systems must be better understood. Additionally, system designs must be optimized in order to maximize fluxes of critical plasma species to the liquid phase. With objectives to increase understanding of these systems and optimize their applications, we have performed both comprehensive modeling and experimental work. To date, models of plasma-liquids have focused on configurations where diffusion is the dominant transport process in both gas and liquid phases. However, convection plays a key role in many popular plasma source designs, including jets, corona discharges, and torches. In this dissertation, we model momentum, heat, and neutral species mass transfer in a convection-dominated system based on a corona discharge. We show that evaporative cooling produced by gas-phase convection can lead to a significant difference between gas and liquid phase bulk temperatures. Additionally, convection induced in the liquid phase by the gas phase flow substantially increases interfacial mass transfer of hydrophobic species like NO and NO2. Finally, liquid kinetic modeling suggests that concentrations of highly reactive species like OH and ONOOH are several orders of magnitude higher at the interface than in the solution bulk. Subsequent modeling has focused on coupling discharge physics with species transport at and through the interface. An assumption commonly seen in the literature is that interfacial loss coefficients of charged species like electrons are equal to unity. However, there is no experimental evidence to either deny or support this assumption. Without knowing the true interfacial behavior of electrons, we have explored the effects on key plasma-liquid variables of varying interfacial parameters like the electron and energy

  20. Determination of trace amounts of rare-earth elements in highly pure neodymium oxide by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) and high-performance liquid chromatography (HPLC) techniques

    International Nuclear Information System (INIS)

    Pedreira, W.R.; Sarkis, J.E.S.; Silva Queiroz, C.A. da; Rodrigues, C.; Tomiyoshi, I.A.; Abrao, A.

    2003-01-01

    Recently rare-earth elements (REE) have received much attention in fields of geochemistry and industry. Rapid and accurate determinations of them are increasingly required as industrial demands expand. Sector field inductively coupled plasma mass spectrometry (ICP-SFMS) with high-performance liquid chromatography (HPLC) has been applied to the determination of REE. HR ICP-MS was used as an element-selective detector for HPLC in highly pure materials. The separation of REE with HPLC helped to avoid erroneous analytical results due to spectral interferences. Sixteen elements (Sc, Y and 14 lanthanides) were determined selectively with the HPLC/ICP-SFMS system using a concentration gradient methods. The detection limits with the HPLC/ICP-SFMS system were about 0.5-10 pg mL -1 . The percentage recovery ranged from 90% to 100% for different REE. The %RSD of the methods varying between 2.5% and 4.5% for a set of five (n=5) replicates was found for the IPEN's material and for the certificate reference sample. Determination of trace REEs in two highly pure neodymium oxides samples (IPEN and Johnson Matthey Company) were performed. In short, the IPEN's materials which are highly pure (>99.9%) were successfully analyzed without spectral interferences

  1. Method for Ultratrace Level (241)Am Determination in Large Soil Samples by Sector Field-Inductively Coupled Plasma Mass Spectrometry: With Emphasis on the Removal of Spectral Interferences and Matrix Effect.

    Science.gov (United States)

    Wang, Zhongtang; Zheng, Jian; Cao, Liguo; Tagami, Keiko; Uchida, Shigeo

    2016-07-19

    A new method using sector field-inductively coupled plasma mass spectrometry (SF-ICPMS) was developed for the determination of (241)Am in large soil samples to provide realistic soil-plant transfer parameter data for dose assessment of nuclear waste disposal plans. We investigated four subjects: extraction behaviors of interfering elements (Bi, Tl, Hg, Pb, Hf, and Pt) on DGA resin (normal type, abbreviated as DGA-N); soil matrix element removal (Mg, Fe, Al, K, Na) using Fe(OH)3, CaF2, and CaC2O4 coprecipitations; Am and rare earth elements (REEs) separation on DGA-N and TEVA resins; and optimization of SF-ICPMS (equipped with a high efficiency nebulizer (HEN)) for Am determination. Our method utilized concentrated HNO3 to leach Am from 2 to 20 g soil samples. The CaC2O4 coprecipitation was used to remove major metals in soil and followed by Am/interfering elements separation using the proposed UTEVA + DGA-N procedure. After a further separation of REEs on TEVA resin, (241)Am was determined by HEN-SF-ICPMS. This method eliminated the matrix effect in ICPMS (241)Am measurement for large soil samples. The high decontamination factors (DFs) of interfering elements enable their thorough removal, and in particular, the DF of Pu (7 × 10(5)) was the highest ever reported in (241)Am studies; thus, this method is capable of analyzing (241)Pu-contaminated Fukushima Daiichi Nuclear Power Plant (FDNPP) sourced soil samples. A low detection limit of 0.012 mBq g(-1) for (241)Am was achieved. The chemical recovery of Am (76-82%) was stable for soil samples. This method can be employed for the low level (241)Am determination in large size soil samples that are contaminated with (241)Pu.

  2. Theory and simulation of laser plasma coupling

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1979-01-01

    The theory and simulation of these coupling processes are considered. Particular emphasis is given to their nonlinear evolution. First a brief introduction to computer simulation of plasmas using particle codes is given. Then the absorption of light via the generation of plasma waves is considered, followed by a discussion of stimulated scattering of intense light. Finally these calculations are compared with experimental results

  3. Comparison of microconcentric and membrane-desolvation sample introduction systems for determination of low rare earth element concentrations in surface and subsurface waters using sector field inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chung, C.-H. [Department of Earth Sciences and Earth Dynamic System Research Center (EDSRC), National Cheng Kung University, Tainan, 70101, Taiwan (China); Brenner, Isaac [Department of Earth Sciences and Earth Dynamic System Research Center (EDSRC), National Cheng Kung University, Tainan, 70101, Taiwan (China)], E-mail: Brenner@cc.huji.ac.il; You, C.-F. [Department of Earth Sciences and Earth Dynamic System Research Center (EDSRC), National Cheng Kung University, Tainan, 70101, Taiwan (China)

    2009-09-15

    Analytical performances of a microconcentric nebulizer (MCN) and a membrane-desolvation sample introduction system (Aridus) were compared for determination of low concentrations of rare earth elements (REEs) in surface and subsurface waters using a double focusing sector field inductively coupled plasma mass spectrometer. Conventional figures of merit were employed, such as sensitivities, limits of detection (LOD), REE-O{sup +} formation, matrix induced interferences, long term signal variations, and recovery from spiked sea water samples and a pristine water CRM. Sensitivity as a function of mass for the MCN was quite flat with the exception of light REE (LREE{sup +}) which was dependent on REE-O{sup +} generation. Signal responses using the Aridus were enhanced by factors of 4-10. Large sensitivity enhancements were observed for {sup 139}La{sup +}, {sup 140}Ce{sup +} and {sup 141}Pr{sup +}, due to the attenuation of their REE-O{sup +} (where the Aridus {sup 140}Ce{sup 16}O{sup +}/{sup 140}Ce{sup +} was three orders of magnitude lower than that determined using the MCN) as a result of water analysis reduction in the plasma. Despite higher sensitivities, Aridus LODs were not significantly different from those obtained using the MCN, and values varied from 0.05 to 0.2 ng L{sup - 1} and 0.1 to 0.2 ng L{sup - 1} for the MCN and Aridus systems, respectively. When using the MCN, LREE{sup +} signals were closely associated with REE-O bond strengths, implying that LREE-O{sup +} production and breakdown are related to the strength of REE-O bonds in REE-O{sup +} ions suggesting that medium REE (MREE)-O{sup +} and heavy REE (HREE)-O{sup +} if formed, were thermally unstable in the plasma. In the presence of conservative Na concentrations, MCN LREE{sup +} signal suppressions varied from about 15 to 25% and about 5 to 10% for MREE{sup +} and HREE{sup +}. In contrast, regular 15% signal suppressions for all REE{sup +} were observed for the Aridus. In the case of the MCN, more

  4. Impurity screening in strongly coupled plasma systems

    CERN Document Server

    Kyrkos, S

    2003-01-01

    We present an overview of the problem of screening of an impurity in a strongly coupled one-component plasma within the framework of the linear response (LR) theory. We consider 3D, 2D and quasi-2D layered systems. For a strongly coupled plasma the LR can be determined by way of the known S(k) structure functions. In general, an oscillating screening potential with local overscreening and antiscreening regions emerges. In the case of the bilayer, this phenomenon becomes global, as overscreening develops in the layer of the impurity and antiscreening in the adjacent layer. We comment on the limitations of the LR theory in the strong coupling situation.

  5. Plasma edge modelling with ICRF coupling

    Directory of Open Access Journals (Sweden)

    Zhang Wei

    2017-01-01

    Full Text Available The physics of Radio-Frequency (RF wave heating in the Ion Cyclotron Range of Frequencies (ICRF in the core plasmas of fusion devices are relatively well understood while those in the Scrape-Off Layer (SOL remain still unresolved. This paper is dedicated to study the ICRF interactions with the plasma edge, mainly from the theoretical and numerical point of view, in particular with the 3D edge plasma fluid and neutral transport code EMC3-EIRENE and various wave codes. Here emphasis is given to the improvement of ICRF coupling with local gas puffing and to the ICRF induced density convection in the SOL.

  6. Dark Sectors and New, Light, Weakly-Coupled Particles

    Energy Technology Data Exchange (ETDEWEB)

    Essig, Rouven [YITP, Stony Brook; Jaros, John A. [SLAC; Wester, William [Fermilab

    1900-01-01

    Dark sectors, consisting of new, light, weakly-coupled particles that do not interact with the known strong, weak, or electromagnetic forces, are a particularly compelling possibility for new physics. Nature may contain numerous dark sectors, each with their own beautiful structure, distinct particles, and forces. This review summarizes the physics motivation for dark sectors and the exciting opportunities for experimental exploration. It is the summary of the Intensity Frontier subgroup \\New, Light, Weakly-coupled Particles" of the Community Summer Study 2013 (Snowmass). We discuss axions, which solve the strong CP problem and are an excellent dark matter candidate, and their generalization to axion-like particles. We also review dark photons and other dark-sector particles, including sub-GeV dark matter, which are theoretically natural, provide for dark matter candidates or new dark matter interactions, and could resolve outstanding puzzles in particle and astro-particle physics. In many cases, the exploration of dark sectors can proceed with existing facilities and comparatively modest experiments. A rich, diverse, and lowcost experimental program has been identied that has the potential for one or more game-changing discoveries. These physics opportunities should be vigorously pursued in the US and elsewhere.

  7. Determination of iodine at ppt level in a nitric acid medium by inductively coupled plasma sector field mass spectrometry: influence of the chemical forms; Etude de la determination de traces d'iode en solution par spectrometrie de masse a secteur magnetique utilisant un plasma a couplage inductif comme source d'ionisation: influence de la forme chimique

    Energy Technology Data Exchange (ETDEWEB)

    Langlois, B

    2001-07-01

    Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP/SFMS) was used to determine several chemical forms of iodine, at ppt level, in a nitric acid media. Ascorbic acid was added as a reducing agent in order to maintain iodine as iodide. In a preliminary approach, the influence of the chemical form was studied by comparing inorganic iodine (NaI) and organic iodine (CH3I). Different signal responses were observed. With a conventional sample introduction system, sensitivities obtained for iodo-methane could differ by a factor of 5. This was not caused by a problem of atomization or by a change in the ionization efficiency of the iodo-compound into the plasma. The low volatilization temperature of iodo-methane (315.5 K) seemed to be the main explanation of this phenomena. Actually, nebulization resulted in the volatilization of a 2% nitric acid solution containing iodo-methane. As a result, the transport efficiency of iodo-methane between the nebulizer and the torch was approaching 100%. A Direct Injection High Efficiency Nebulizer (DIHEN) allowed us to minimize the behavior difference between the two iodine species, but the sensitivity ratio was inverted and still differed by 20 - 40%. Moreover, the association of a guard electrode and the direct injection system was studied in order to apply these equipments to the determination of iodine. This association allowed us to improve the sensitivity by a factor of 10 and to minimize memory effects, when compared with a conventional system. Further studies indicated that signal responses obtained with different iodine-containing species, except for iodo-methane, were found to be similar. (author)

  8. Intense Shock Waves and Strongly Coupled Plasmas

    Science.gov (United States)

    Fortov, Vladimir

    2005-07-01

    The report presents the recent results of experimental investigations of equations of state, compositions, thermodynamical and transport properties, electrical conductivity and opacity of strongly coupled plasmas generated by intense shock and rarefaction waves. The experimental methods for generation of high energy densities in matter, drivers for shock waves and fast diagnostic tools are discussed. Application of intense shock waves to solid and porous targets generates nonideal plasmas in megabar-gigabar pressure range. Compression of plasma by a series of reverberating shock waves allows us to decrease irreversible heating effects. To increase the irreversibility effects and to generate high temperature plasma states the experiments on shock compression of porous samples (fine metal powder, aerogels) were performed. The adiabatic expansion of matter initially compressed by intense shocks up to megabars allows investigating the intermediate region between the solid and vapor phase of nonideal plasmas, including the metal-insulator transition phase and the high temperature saturation curve with critical points of metals. The shock-wave-induced non-equilibrium phenomena at fast melting, spallation and adiabatic condensation are analyzed in the framework of the interspinodal decomposition model. The spall strength of single and polycrystal metals at extremely fast deformation produced by fast shock waves is discussed. The ``pressure ionization'' phenomena in hydrogen, helium, argon, xenon, krypton, neon, iodine, silica, sulfur, fullerenes, and some metals are analyzed on the base of multiple shock compression experiments. For some simple metals (Li, Na, Ca) the effect of ``dielectrization'' as a result of multiple shock compression are discussed.

  9. Double plasma system with inductively coupled source plasma and quasi-quiescent target plasma

    International Nuclear Information System (INIS)

    Massi, M.; Maciel, H.S.

    1995-01-01

    Cold plasmas have successfully been used in the plasma-assisted material processing industry. An understanding of the physicochemical mechanisms involved in the plasma-surface interaction is needed for a proper description of deposition and etching processes at material surfaces. Since these mechanisms are dependent on the plasma properties, the development of diagnostic techniques is strongly desirable for determination of the plasma parameters as well as the characterization of the electromagnetic behaviour of the discharge. In this work a dual discharge chamber, was specially designed to study the deposition of thin films via plasma polymerization process. In the Pyrex chamber an inductively coupled plasma can be excited either in the diffuse low density E-mode or in the high density H-mode. This plasma diffuses into the cylindrical stainless steel chamber which is covered with permanent magnets to produce a multidipole magnetic field configuration at the surface. By that means a double plasma is established consisting of a RF source plasma coupled to a quasi-quiescent target plasma. The preliminary results presented here refer to measurements of the profiles of plasma parameters along the central axis of the double plasma apparatus. Additionally a spectrum analysis performed by means of a Rogowski coil probe immersed into the source plasma is also presented. The discharge is made in argon with pressure varying from 10 -2 to 1 torr, and the rf from 10 to 150 W

  10. Titanium oxidation by rf inductively coupled plasma

    International Nuclear Information System (INIS)

    Valencia-Alvarado, R; López-Callejas, R; Barocio, S R; Mercado-Cabrera, A; Peña-Eguiluz, R; Muñoz-Castro, A E; Rodríguez-Méndez, B G; De la Piedad-Beneitez, A; De la Rosa-Vázquez, J M

    2014-01-01

    The development of titanium dioxide (TiO 2 ) films in the rutile and anatase phases is reported. The films have been obtained from an implantation/diffusion and sputtering process of commercially pure titanium targets, carried out in up to 500 W plasmas. The experimental outcome is of particular interest, in the case of anatase, for atmospheric pollution degradation by photocatalysis and, as to the rutile phase, for the production of biomaterials required by prosthesis and implants. The reactor employed consists in a cylindrical pyrex-like glass vessel inductively coupled to a 13.56 MHz RF source. The process takes place at a 5×10 −2 mbar pressure with the target samples being biased from 0 to -3000 V DC. The anatase phase films were obtained from sputtering the titanium targets over glass and silicon electrically floated substrates placed 2 cm away from the target. The rutile phase was obtained by implantation/diffusion on targets at about 700 °C. The plasma was developed from a 4:1 argon/oxygen mixture for ∼5 hour processing periods. The target temperature was controlled by means of the bias voltage and the plasma source power. The obtained anatase phases did not require annealing after the plasma oxidation process. The characterization of the film samples was conducted by means of x-ray diffraction, scanning electron microscopy, x-ray photoelectron spectroscopy and Raman spectroscopy

  11. Instabilities in a capacitively coupled oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Küllig, C., E-mail: kuellig@physik.uni-greifswald.de; Wegner, Th., E-mail: physics@thwegner.com; Meichsner, J., E-mail: meichsner@physik.uni-greifswald.de [Institute of Physics, University of Greifswald, Felix-Hausdorff-Str. 6, 17489 Greifswald (Germany)

    2015-04-15

    Periodic fluctuations in the frequency range from 0.3 to 3 kHz were experimentally investigated in capacitively coupled radio frequency (13.56 MHz) oxygen plasma. The Gaussian beam microwave interferometry directly provides the line integrated electron density fluctuations. A system of two Langmuir probes measured the floating potential spatially (axial, radial) and temporally resolved. Hence, the floating potential fluctuation development is mapped within the discharge volume and provides a kind of discharge breathing and no wave propagation. Finally, it was measured the optical emission pattern of atomic oxygen during the fluctuation as well as the RF phase resolved optical emission intensity at selected phase position of the fluctuation by an intensified charge-coupled device camera. The deduced excitation rate pattern reveals the RF sheath dynamics and electron heating mechanisms, which is changing between low and high electronegativity during a fluctuation cycle. A perturbation calculation was taken into account using a global model with 15 elementary collision processes in the balance equations for the charged plasma species (O{sub 2}{sup +}, e, O{sup −}, O{sub 2}{sup −}) and a harmonic perturbation. The calculated frequencies agree with the experimentally observed frequencies. Whereby, the electron attachment/detachment processes are important for the generation of this instability.

  12. Electromagnetic modes in cold magnetized strongly coupled plasmas

    OpenAIRE

    Tkachenko, I. M.; Ortner, J.; Rylyuk, V. M.

    1999-01-01

    The spectrum of electromagnetic waves propagating in a strongly coupled magnetized fully ionized hydrogen plasma is found. The ion motion and damping being neglected, the influence of the Coulomb coupling on the electromagnetic spectrum is analyzed.

  13. Hydrogen atom kinetics in capacitively coupled plasmas

    Science.gov (United States)

    Nunomura, Shota; Katayama, Hirotaka; Yoshida, Isao

    2017-05-01

    Hydrogen (H) atom kinetics has been investigated in capacitively coupled very high frequency (VHF) discharges at powers of 16-780 mW cm-2 and H2 gas pressures of 0.1-2 Torr. The H atom density has been measured using vacuum ultra violet absorption spectroscopy (VUVAS) with a micro-discharge hollow cathode lamp as a VUV light source. The measurements have been performed in two different electrode configurations of discharges: conventional parallel-plate diode and triode with an intermediate mesh electrode. We find that in the triode configuration, the H atom density is strongly reduced across the mesh electrode. The H atom density varies from ˜1012 cm-3 to ˜1010 cm-3 by crossing the mesh with 0.2 mm in thickness and 36% in aperture ratio. The fluid model simulations for VHF discharge plasmas have been performed to study the H atom generation, diffusion and recombination kinetics. The simulations suggest that H atoms are generated in the bulk plasma, by the electron impact dissociation (e + H2 \\to e + 2H) and the ion-molecule reaction (H2 + + H2 \\to {{{H}}}3+ + H). The diffusion of H atoms is strongly limited by a mesh electrode, and thus the mesh geometry influences the spatial distribution of the H atoms. The loss of H atoms is dominated by the surface recombination.

  14. Plasma blobs associated with plasma bubbles observed in the Brazilian sector

    Science.gov (United States)

    Tardelli-Coelho, F.; Pimenta, A. A.; Tardelli, A.; Abalde, J. R.; Venkatesh, K.

    2017-10-01

    In this paper we present a case of plasma blobs associated with plasma bubbles which were observed by emission of OI 630.0 nm airglow, using ground-based (all-sky images) and DMSP-F15 satellite data on 23 February 2007, over a low latitude station São José dos Campos (SJC) (23.21°S, 45.86°W; dip latitude 18.3°S) in the Brazilian sector. We calculated the zonal drift velocities of the plasma bubble and plasma blobs, and the longitudinal drift of the blobs that occurred that night using the linearization method presented by Pimenta et al. (2001). The north/south and east/west extensions of plasma blobs have also been estimated. The mean velocity of the plasma bubble is found to be 74 ± 8 m/s and the plasma blob zonal drift is 61 ± 6 m/s. The average velocity of the longitudinal drift of the plasma blob was 85 ± 13 m/s and the analyzed blobs had the mean north/south extension of 591 km and east/west extension of 328 and 263 km.

  15. On coupling fluid plasma and kinetic neutral physics models

    OpenAIRE

    Joseph, I.; Rensink, M.E.; Stotler, D.P.; Dimits, A.M.; LoDestro, L.L.; Porter, G.D.; Rognlien, T.D.; Sjogreen, B.; Umansky, M.V.

    2017-01-01

    The coupled fluid plasma and kinetic neutral physics equations are analyzed through theory and simulation of benchmark cases. It is shown that coupling methods that do not treat the coupling rates implicitly are restricted to short time steps for stability. Fast charge exchange, ionization and recombination coupling rates exist, even after constraining the solution by requiring that the neutrals are at equilibrium. For explicit coupling, the present implementation of Monte Carlo correlated sa...

  16. Inductively coupled plasma-atomic emission spectroscopy

    International Nuclear Information System (INIS)

    Winge, R.K.; Fassel, V.A.; Peterson, V.J.; Floyd, M.A.

    1985-01-01

    This atlas of inductively coupled plasma-atomic emission spectroscopy records the spectra of the elements in a way that would reveal the general nature of the spectra, in all their simplicity or complexity; and offers a definitive summary of the most prominent spectral lines of the elements, i.e., those most likely to be useful for the determination of trace and ultratrace concentrations; it provides reliable estimates, based on the recorded experimental spectra, of the powers of detection of the listed prominent lines; and assesses the very important problem of spectral interferences. The atlas is composed of three main sections. Part I is concerned with the historical aspects of compilations of spectral information. Part II is based on 232 wavelength scans of 70 elements. Each of the wavelength scans covers an 80 nm spectral region. These scans allow a rapid comparison of the background and spectral line intensities emitted in the ICP and provide a ready means for identification of the most prominent lines of each element and for estimation of the trace element analytical capabilities of these lines. A listing of 973 prominent lines with associated detection limits is also presented. Part III addresses the problem of spectral interferences. On this topic a detailed collection of coincidence profiles is presented for 281 of the most prominent lines, each with profiles of ten of the most prevalent concomitants superimposed. (Auth.)

  17. Shear viscosities of photons in strongly coupled plasmas

    Directory of Open Access Journals (Sweden)

    Di-Lun Yang

    2016-09-01

    Full Text Available We investigate the shear viscosity of thermalized photons in the quark gluon plasma (QGP at weak coupling and N=4 super Yang–Mills plasma (SYMP at both strong and weak couplings. We find that the shear viscosity due to the photon–parton scattering up to the leading order of electromagnetic coupling is suppressed when the coupling of the QGP/SYMP is increased, which stems from the blue-shift of the thermal-photon spectrum at strong coupling. In addition, the shear viscosity rapidly increases near the deconfinement transition in a phenomenological model analogous to the QGP.

  18. A Method to Construct Plasma with Nonlinear Density Enhancement Effect in Multiple Internal Inductively Coupled Plasmas

    International Nuclear Information System (INIS)

    Chen Zhipeng; Li Hong; Liu Qiuyan; Luo Chen; Xie Jinlin; Liu Wandong

    2011-01-01

    A method is proposed to built up plasma based on a nonlinear enhancement phenomenon of plasma density with discharge by multiple internal antennas simultaneously. It turns out that the plasma density under multiple sources is higher than the linear summation of the density under each source. This effect is helpful to reduce the fast exponential decay of plasma density in single internal inductively coupled plasma source and generating a larger-area plasma with multiple internal inductively coupled plasma sources. After a careful study on the balance between the enhancement and the decay of plasma density in experiments, a plasma is built up by four sources, which proves the feasibility of this method. According to the method, more sources and more intensive enhancement effect can be employed to further build up a high-density, large-area plasma for different applications. (low temperature plasma)

  19. Ideal gas behavior of a strongly coupled complex (dusty) plasma.

    Science.gov (United States)

    Oxtoby, Neil P; Griffith, Elias J; Durniak, Céline; Ralph, Jason F; Samsonov, Dmitry

    2013-07-05

    In a laboratory, a two-dimensional complex (dusty) plasma consists of a low-density ionized gas containing a confined suspension of Yukawa-coupled plastic microspheres. For an initial crystal-like form, we report ideal gas behavior in this strongly coupled system during shock-wave experiments. This evidence supports the use of the ideal gas law as the equation of state for soft crystals such as those formed by dusty plasmas.

  20. Energy coupling to the plasma in repetitive nanosecond pulse discharges

    International Nuclear Information System (INIS)

    Adamovich, Igor V.; Nishihara, Munetake; Choi, Inchul; Uddi, Mruthunjaya; Lempert, Walter R.

    2009-01-01

    A new analytic quasi-one-dimensional model of energy coupling to nanosecond pulse discharge plasmas in plane-to-plane geometry has been developed. The use of a one-dimensional approach is based on images of repetitively pulsed nanosecond discharge plasmas in dry air demonstrating that the plasma remains diffuse and uniform on a nanosecond time scale over a wide range of pressures. The model provides analytic expressions for the time-dependent electric field and electron density in the plasma, electric field in the sheath, sheath boundary location, and coupled pulse energy. The analytic model predictions are in very good agreement with numerical calculations. The model demonstrates that (i) the energy coupled to the plasma during an individual nanosecond discharge pulse is controlled primarily by the capacitance of the dielectric layers and by the breakdown voltage and (ii) the pulse energy coupled to the plasma during a burst of nanosecond pulses decreases as a function of the pulse number in the burst. This occurs primarily because of plasma temperature rise and resultant reduction in breakdown voltage, such that the coupled pulse energy varies approximately proportionally to the number density. Analytic expression for coupled pulse energy scaling has been incorporated into the air plasma chemistry model, validated previously by comparing with atomic oxygen number density measurements in nanosecond pulse discharges. The results of kinetic modeling using the modified air plasma chemistry model are compared with time-resolved temperature measurements in a repetitively pulsed nanosecond discharge in air, by emission spectroscopy, and purely rotational coherent anti-Stokes Raman spectroscopy showing good agreement.

  1. Driven transverse shear waves in a strongly coupled dusty plasma

    International Nuclear Information System (INIS)

    Bandyopadhyay, P.; Prasad, G.; Sen, A.; Kaw, P.K.

    2008-01-01

    The linear dispersion properties of transverse shear waves in a strongly coupled dusty plasma are experimentally studied in a DC discharge device by exciting them in a controlled manner with a variable frequency external source. The dusty plasma is maintained in the strongly coupled fluid regime with (1 c ) where Γ is the Coulomb coupling parameter and Γ c is the crystallization limit. A dispersion relation for the transverse waves is experimentally obtained over a frequency range of 0.1 Hz to 2 Hz and found to show good agreement with viscoelastic theoretical results

  2. Solar terrestrial coupling through space plasma processes

    International Nuclear Information System (INIS)

    Birn, J.

    2000-01-01

    This is the final report of a three-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The project investigates plasma processes that govern the interaction between the solar wind, charged particles ejected from the sun, and the earth's magnetosphere, the region above the ionosphere governed by the terrestrial magnetic field. Primary regions of interest are the regions where different plasma populations interact with each other. These are regions of particularly dynamic plasma behavior, associated with magnetic flux and energy transfer and dynamic energy release. The investigations concerned charged particle transport and energization, and microscopic and macroscopic instabilities in the magnetosphere and adjacent regions. The approaches combined space data analysis with theory and computer simulations

  3. SU-8 etching in inductively coupled oxygen plasma

    DEFF Research Database (Denmark)

    Rasmussen, Kristian Hagsted; Keller, Stephan Sylvest; Jensen, Flemming

    2013-01-01

    Structuring or removal of the epoxy based, photo sensitive polymer SU-8 by inductively coupled plasma reactive ion etching (ICP-RIE) was investigated as a function of plasma chemistry, bias power, temperature, and pressure. In a pure oxygen plasma, surface accumulation of antimony from the photo......-initiator introduced severe roughness and reduced etch rate significantly. Addition of SF6 to the plasma chemistry reduced the antimony surface concentration with lower roughness and higher etch rate as an outcome. Furthermore the etch anisotropy could be tuned by controlling the bias power. Etch rates up to 800 nm...

  4. A strongly coupled quark-gluon plasma

    Energy Technology Data Exchange (ETDEWEB)

    Shuryak, Edward [Department of Physics and Astronomy, University at Stony Brook, NY 11794 (United States)

    2004-08-01

    Successful description of robust collective flow phenomena at RHIC by ideal hydrodynamics, recent observations of bound c-barc,q-barq states on the lattice, and other theoretical developments indicate that QGP produced at RHIC, and probably in a wider temperature region T{sub c} < T < 4T{sub c}, is not a weakly coupled quasiparticle gas as believed previously. We discuss how strong the interaction is and why it seems to generate hundreds of binary channels with bound states, surviving well inside the QGP phase. We in particular discuss their effect on pressure and viscosity. We conclude by reviewing the similar phenomena for other 'strongly coupled systems', such as (i) strongly coupled supersymmetric theories studied via Maldacena duality; (ii) trapped ultra-cold atoms with very large scattering length, tuned to Feschbach resonances.

  5. Search for Anomalous Couplings in the Higgs Sector at LEP

    CERN Document Server

    Achard, P; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Anderhub, H; Andreev, V P; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Baldew, S V; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, Maurice; Braccini, S; Branson, J G; Brochu, F; Burger, J D; Burger, W J; Cai, X D; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A M; Casaus, J; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Chamizo-Llatas, M; Chang, Y H; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, Luisa; Cindolo, F; Clare, I; Clare, R; Coignet, G; Colino, N; Costantini, S; de la Cruz, B; Cucciarelli, S; van Dalen, J A; De Asmundis, R; Déglon, P L; Debreczeni, J; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Dionisi, C; Dittmar, M; Doria, A; Dova, M T; Duchesneau, D; Duda, M; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Extermann, P; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Fisk, I; Forconi, G; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gentile, S; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; van Gulik, R; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hou, S R; Hu, Y; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kaur, M; Kienzle-Focacci, M N; Kim, J K; Kirkby, Jasper; Kittel, E W; Klimentov, A; König, A C; Kopal, M; Koutsenko, V F; Kräber, M H; Krämer, R W; Krüger, A; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Le Goff, J M; Leiste, R; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Luci, C; Luminari, L; Lustermann, W; Ma Wen Gan; Malgeri, L; Malinin, A; Maña, C; Mans, J; Martin, J P; Marzano, F; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Meschini, M; Metzger, W J; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Muanza, G S; Muijs, A J M; Musicar, B; Musy, M; Nagy, S; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Pal, I; Palomares, C; Paolucci, P; Paramatti, R; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Pedace, M; Pensotti, S; Perret-Gallix, D; Petersen, B; Piccolo, D; Pierella, F; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Pothier, J; Prokofev, D; Prokofiev, D O; Quartieri, J; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P A; Ren, D; Rescigno, M; Reucroft, S; Riemann, S; Riles, K; Roe, B P; Romero, L; Rosca, A; Rosemann, C; Rosenbleck, C; Rosier-Lees, S; Roth, S; Rubio, J A; Ruggiero, G; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Schäfer, C; Shchegelskii, V; Schopper, Herwig Franz; Schotanus, D J; Sciacca, C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A V; Son, D; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Szillási, Z; Tang, X W; Tarjan, P; Tauscher, Ludwig; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Ulbricht, J; Valente, E; Van de Walle, R T; Vásquez, R; Veszpremi, V; Vesztergombi, G; Vetlitskii, I; Vicinanza, D; Viertel, Gert M; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Wadhwa, M; Wang, Q; Wang, X L; Wang, Z M; Weber, M; Wilkens, H; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Yeh, S C; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zimmermann, B; Zöller, M

    2004-01-01

    Anomalous couplings of the Higgs boson are searched for through the processes e^+ e^- -> H gamma, e^+ e^- -> e^+ e^- H and e^+ e^- -> HZ. The mass range 70 GeV ffbar, H -> gamma gamma, H -> Z\\gamma and H -> WW^(*) are considered and no evidence is found for anomalous Higgs production or decay. Limits on the anomalous couplings d, db, Delta(g1z), Delta(kappa_gamma) and xi^2 are derived as well as limits on the H -> gamma gamma and H -> Z gamma decay rates.

  6. High efficiency nebulization for helium inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Jorabchi, Kaveh; McCormick, Ryan; Levine, Jonathan A.; Liu Huiying; Nam, S.-H.; Montaser, Akbar

    2006-01-01

    A pneumatically-driven, high efficiency nebulizer is explored for helium inductively coupled plasma mass spectrometry. The aerosol characteristics and analyte transport efficiencies of the high efficiency nebulizer for nebulization with helium are measured and compared to the results obtained with argon. Analytical performance indices of the helium inductively coupled plasma mass spectrometry are evaluated in terms of detection limits and precision. The helium inductively coupled plasma mass spectrometry detection limits obtained with the high efficiency nebulizer at 200 μL/min are higher than those achieved with the ultrasonic nebulizer consuming 2 mL/min solution, however, precision is generally better with high efficiency nebulizer (1-4% vs. 3-8% with ultrasonic nebulizer). Detection limits with the high efficiency nebulizer at 200 μL/min solution uptake rate approach those using ultrasonic nebulizer upon efficient desolvation with a heated spray chamber followed by a Peltier-cooled multipass condenser

  7. Development of a low-cost inductively coupled argon plasma

    International Nuclear Information System (INIS)

    Ripson, P.A.M.

    1983-01-01

    The aim of this investigation is to drastically reduce running costs of an inductively coupled plasma. This is done by reducing the argon consumption from 20 l/min to about 1 l/min. First, a sample introduction system operating on 0.1 l/min of carrier argon is described. This system ensures a high ratio of plasma argon and carrier argon even at the low total argon consumptions intended. Next, the developed low consumption plasma is presented. In the proposed design, air is blown perpendicularly against the outside of the torch. A different coil has been developed to make air-cooling efficient. Preliminary data on coupling efficiency for the air-cooled plasma are presented. A similarly low argon consumption has been achieved with water as an external coolant medium. It is concluded that a cheaper alternative to the current ICP has become available. (Auth.)

  8. Non-local heating theory inductively coupled plasma discharge

    International Nuclear Information System (INIS)

    Yoon, N.S.; You, K.I.; Hwang, S.M.; Choi, D.I.

    1998-01-01

    Recently developed one- and two-dimensional non-local heating theories of planar type inductively coupled plasma discharge are reviewed and some extensions of the results are presented. The important results of the one- and two-dimensional theories are integrated into the representative concepts of surface impedance and impedance of plasma respectively. Relevant physics are discussed and the works in progress are presented. (author)

  9. Equation of state of strongly coupled plasma mixtures

    International Nuclear Information System (INIS)

    DeWitt, H.E.

    1984-01-01

    Thermodynamic properties of strongly coupled (high density) plasmas of mixtures of light elements have been obtained by Monte Carlo simulations. For an assumed uniform charge background the equation of state of ionic mixtures is a simple extension of the one-component plasma EOS. More realistic electron screening effects are treated in linear response theory and with an appropriate electron dielectric function. Results have been obtained for the ionic pair distribution functions, and for the electric microfield distribution

  10. Transport Phenomena in Magnetized Plasmas across Coupling Regimes

    Science.gov (United States)

    Baalrud, Scott; Daligault, Jerome

    2015-11-01

    Plasmas with components that are magnetized, strongly coupled, or both arise in a variety of frontier plasma physics experiments including magnetized dusty plasmas, magnetized ICF concepts, as well as from self-generated fields in ICF. Here, a theory is described that treats classical mixtures of magnetized and unmagnetized species across coupling regimes. The approach is based on an extension of the recent effective potential transport theory to include a magnetic field. The utility of this approach is that it can be incorporated into magnetohydrodynamic descriptions by modification of the Coulomb logarithm in the transport coefficients. Like weakly coupled plasma theory, the magnetic field is found to suppress cross-field transport. However, the ratio of parallel to cross field transport rates is much closer to unity at strong coupling. Not only cross field, but also parallel, transport rates are found to be reduced by the field. Results are compared with classical molecular dynamics simulations of self-diffusion of the one component plasma, and with simulations of parallel to perpendicular temperature equilibration of an initially anisotropic distribution. The authors gratefully acknowledge support from Los Alamos National Laboratory grant LDRD 20150520ER.

  11. A Tightly Coupled Non-Equilibrium Magneto-Hydrodynamic Model for Inductively Coupled RF Plasmas

    Science.gov (United States)

    2016-02-29

    Journal Article 3. DATES COVERED (From - To) 12 May 2015 – 06 Oct 2015 4. TITLE AND SUBTITLE A Tightly Coupled Non- Equilibrium Magneto-Hydrodynamic...development a tightly coupled magneto-hydrodynamic model for Inductively Coupled Radio- Frequency (RF) Plasmas. Non Local Thermodynamic Equilibrium (NLTE...effects are described based on a hybrid State-to-State (StS) approach. A multi-temperature formulation is used to account for thermal non- equilibrium

  12. Plasma ICR heating antennas: adaptation, radiated field structure, coupling

    International Nuclear Information System (INIS)

    Pegourie, B.

    1982-01-01

    The transmission line theory has been used to find the antenna adapattion improvement possibilities, so as to optimize the power transfer from generator to plasma. ICR heating antennas are described, radiated magnetic field is measured, and superstructures (diaphragms and electrostatic screen) is studied from a mock-up and a numerical model. Results about antenna radiation and electric property modifications due to superstructures, without plasma, are presented. At last, TFR antenna coupling properties, in terms of frequency, electromagnetic wave and plasma conditions, are studied. In the whole work, we tried to define, when possible the construction criteria fitted to cyclotron heating in the big tokamak experiments under construction [fr

  13. Strongly coupled stimulated Brillouin amplification in pump-ionizing plasma

    Science.gov (United States)

    Peng, H.; Wu, Z. H.; Zuo, Y. L.; Zhou, K. N.; Wang, X. D.; Li, Q.; Zhu, H. Y.; Su, J. Q.

    2018-02-01

    Laser amplification based on strongly coupled stimulated Brillouin scattering in plasma is investigated. The pump and seed are at the same wavelength of 800 nm and the same duration of 3.5 ps, but with a different intensity. The plasma is produced by the front part of the pump via tunnel ionization from hydrogen. The hydrogen is fully ionized to eliminate small-scale density fluctuations in the plasma, so the transmission level of the seed is enhanced to 22%, and a relative amplification factor of 6 is obtained.

  14. Radial Distribution Functions of Strongly Coupled Two-Temperature Plasmas

    Science.gov (United States)

    Shaffer, Nathaniel R.; Tiwari, Sanat Kumar; Baalrud, Scott D.

    2017-10-01

    We present tests of three theoretical models for the radial distribution functions (RDFs) in two-temperature strongly coupled plasmas. RDFs are useful in extending plasma thermodynamics and kinetic theory to strong coupling, but they are usually known only for thermal equilibrium or for approximate one-component model plasmas. Accurate two-component modeling is necessary to understand the impact of strong coupling on inter-species transport, e.g., ambipolar diffusion and electron-ion temperature relaxation. We demonstrate that the Seuferling-Vogel-Toeppfer (SVT) extension of the hypernetted chain equations not only gives accurate RDFs (as compared with classical molecular dynamics simulations), but also has a simple connection with the Yukawa OCP model. This connection gives a practical means to recover the structure of the electron background from knowledge of the ion-ion RDF alone. Using the model RDFs in Effective Potential Theory, we report the first predictions of inter-species transport coefficients of strongly coupled plasmas far from equilibrium. This work is supported by NSF Grant No. PHY-1453736, AFSOR Award No. FA9550-16-1-0221, and used XSEDE computational resources.

  15. Antenna coupling study for ICWC plasma characterization in TEXTOR

    Indian Academy of Sciences (India)

    2013-01-06

    Jan 6, 2013 ... factory antenna coupling in the mode conversion scenario along with reproducible generation of. ICRF plasmas .... on the determination of the standing wave pattern in the transmission lines between the. ICRH generator ... and rotating poloidal Bp = 1 mT/1–10 Hz (resultant of vertical and radial oscillating.

  16. Antenna coupling study for ICWC plasma characterization in TEXTOR

    Indian Academy of Sciences (India)

    2015-11-27

    Home; Journals; Pramana – Journal of Physics; Volume 80; Issue 1. Antenna coupling study for ICWC plasma characterization in ... Proceedings of the International Workshop/Conference on Computational Condensed Matter Physics and Materials Science (IWCCMP-2015). Posted on November 27, 2015. Guest Editors: ...

  17. Numerical experiments on 2D strongly coupled complex plasmas

    International Nuclear Information System (INIS)

    Hou Lujing; Ivlev, A V; Thomas, H M; Morfill, G E

    2010-01-01

    The Brownian Dynamics simulation method is briefly reviewed at first and then applied to study some non-equilibrium phenomena in strongly coupled complex plasmas, such as heat transfer processes, shock wave excitation/propagation and particle trapping, by directly mimicking the real experiments.

  18. Effects of assistant anode on planar inductively coupled magnetized argon plasma in plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Tang, Deli; Chu, Paul K.

    2003-01-01

    The enhancement of planar radio frequency (RF) inductively coupled argon plasma is studied in the presence of an assistant anode and an external magnetic field at low pressure. The influence of the assistant anode and magnetic field on the efficiency of RF power absorption and plasma parameters is investigated. An external axial magnetic field is coupled into the plasma discharge region by an external electromagnetic coil outside the discharge chamber and an assistant cylindrical anode is inserted into the discharge chamber to enhance the plasma discharge. The plasma parameters and density profile are measured by an electrostatic Langmuir probe at different magnetic fields and anode voltages. The RF power absorption by the plasma can be effectively enhanced by the external magnetic field compared with the nonmagnetized discharge. The plasma density can be further increased by the application of a voltage to the assistant anode. Owing to the effective power absorption and enhanced plasma discharge by the assistant anode in a longitudinal magnetic field, the plasma density can be enhanced by more than a factor of two. Meanwhile, the nonuniformity of the plasma density is less than 10% and it can be achieved in a process chamber with a diameter of 600 mm

  19. Electron energy distributions in a magnetized inductively coupled plasma

    International Nuclear Information System (INIS)

    Song, Sang-Heon; Yang, Yang; Chabert, Pascal; Kushner, Mark J.

    2014-01-01

    Optimizing and controlling electron energy distributions (EEDs) is a continuing goal in plasma materials processing as EEDs determine the rate coefficients for electron impact processes. There are many strategies to customize EEDs in low pressure inductively coupled plasmas (ICPs), for example, pulsing and choice of frequency, to produce the desired plasma properties. Recent experiments have shown that EEDs in low pressure ICPs can be manipulated through the use of static magnetic fields of sufficient magnitudes to magnetize the electrons and confine them to the electromagnetic skin depth. The EED is then a function of the local magnetic field as opposed to having non-local properties in the absence of the magnetic field. In this paper, EEDs in a magnetized inductively coupled plasma (mICP) sustained in Ar are discussed with results from a two-dimensional plasma hydrodynamics model. Results are compared with experimental measurements. We found that the character of the EED transitions from non-local to local with application of the static magnetic field. The reduction in cross-field mobility increases local electron heating in the skin depth and decreases the transport of these hot electrons to larger radii. The tail of the EED is therefore enhanced in the skin depth and depressed at large radii. Plasmas densities are non-monotonic with increasing pressure with the external magnetic field due to transitions between local and non-local kinetics

  20. Improved planar radio frequency inductively coupled plasma configuration in plasma immersion ion implantation

    International Nuclear Information System (INIS)

    Tang, D.L.; Fu, R.K.Y.; Tian, X.B.; Chu, P.K.

    2003-01-01

    Plasmas with higher density and better uniformity are produced using an improved planar radio frequency (rf) inductively coupled plasma configuration in plasma immersion ion implantation (PIII). An axial magnetic field is produced by external electromagnetic coils outside the discharge chamber. The rf power can be effectively absorbed by the plasma in the vicinity of the electron gyrofrequency due to the enhanced resonant absorption of electromagnetic waves in the whistler wave range, which can propagate nearly along the magnetic field lines thus greatly increases the plasma density. The plasma is confined by a longitudinal multipolar cusp magnetic field made of permanent magnets outside the process chamber. It can improve the plasma uniformity without significantly affecting the ion density. The plasma density can be increased from 3x10 9 to 1x10 10 cm -3 employing an axial magnetic field of several Gauss at 1000 W rf power and 5x10 -4 Torr gas pressure. The nonuniformity of the plasma density is less than 10% and can be achieved in a process chamber with a diameter of 600 mm. Since the plasma generation and process chambers are separate, plasma extinction due to the plasma sheath touching the chamber wall in high-energy PIII can be avoided. Hence, low-pressure, high-energy, and high-uniformity ion implantation can be accomplished using this setup

  1. Multilayer optics provides laser--plasma-coupling insight

    International Nuclear Information System (INIS)

    Godwin, R.P.

    1995-01-01

    The Herpin theorem permits the reflectance of an arbitrary medium to be reproduced with a substrate of one complex refractive index overlaid with a coating film of a second complex refractive index and an appropriate thickness. The reflectances of a variety of laser--plasma-coupling experiments can be matched with a simple and physically meaningful procedure for choosing the fitting parameters. For short-pulse experiments, s-light coupling is dominated by substrate interactions at electron densities above critical and p-light coupling is dominated by resonance at the critical density. The weak dependence of resonance absorption on damping is the result of the harmonic-oscillator resonance form. As the plasma scale length becomes vanishingly small, the reflectance is that of the Fresnel equations, but surprisingly small plasma scale lengths have dramatic effects on the p-light reflectance. Film--substrate and WKB models predict similar resonance absorption, where both models are valid approximations and both should agree with multilayer and Helmholtz wave-optics calculations. For plasma scale lengths well below a wavelength, the film--substrate and the vacuum-heating models are closely related

  2. Pair correlation functions of strongly coupled two-temperature plasma

    Science.gov (United States)

    Shaffer, Nathaniel R.; Tiwari, Sanat Kumar; Baalrud, Scott D.

    2017-09-01

    Using molecular dynamics simulations, we perform the first direct tests of three proposed models for the pair correlation functions of strongly coupled plasmas with species of unequal temperature. The models are all extensions of the Ornstein-Zernike/hypernetted-chain theory used to good success for equilibrium plasmas. Each theory is evaluated at several coupling strengths, temperature ratios, and mass ratios for a model plasma in which the electrons are positively charged. We show that the model proposed by Seuferling et al. [Phys. Rev. A 40, 323 (1989)] agrees well with molecular dynamics over a wide range of mass and temperature ratios, as well as over a range of coupling strength similar to that of the equilibrium hypernetted-chain (HNC) theory. The SVT model also correctly predicts the strength of interspecies correlations and exhibits physically reasonable long-wavelength limits of the static structure factors. Comparisons of the SVT model with the Yukawa one-component plasma (YOCP) model are used to show that ion-ion pair correlations are well described by the YOCP model up to Γe≈1 , beyond which it rapidly breaks down.

  3. Strongly coupled dusty plasmas: crystals, liquids, clusters and waves

    International Nuclear Information System (INIS)

    Jeng-Mei Liu; Wen-Tau Juan; Ju-Wang Hsu; Zen-Hong Huang; Lin I

    1999-01-01

    The dusty plasma is a system that consists of many strongly-charged fine dust particles suspended in a plasma background. The slow dynamics and strong coupling due to the large mass and charges lead to the formation of highly-ordered dust crystal structures suspended in the plasma background, which can be directly observed. The dusty plasma forms a link to the area of condensed matter physics for the study of many interesting microscopic phenomena from order to disorder. In this paper, we introduce the special properties of this system from the viewpoint of conventional plasma physics, then we briefly review past works on the structure and dynamical behaviour from the highly-ordered state, through the melting and liquid states with associated vortex-type excitation and anomalous diffusion, to the state with self-organized macroscopic dust waves after losing microscopic order. The first observation of strongly-coupled dust Coulomb clusters with small numbers of particles from a few to a few hundred, which resemble classical atoms, is also demonstrated. (author)

  4. A versatile new torch for inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Ebdon, L.; Mowthorpe, D.J.; Cave, M.R.

    1980-01-01

    A modified torch for optical emission spectrometry with an inductively coupled plasma source is described. The demountable torch incorporates a flared intermediate tube, a capillary injector tube and interchangeable jets at the gas inlets. The optimised performance of the torch is compared with that of a conventional torch. The new torch can be operated over a wide range of gas flows and shows considerable promise in work with an argon-cooled plasma. The ability to operate at high or low gas flow rates, and the possibility of interchanging tubes and jets easily illustrate the versatility of the new design. (Auth.)

  5. Coupled plasma filtration adsorption improves hemodynamics in septic shock.

    Science.gov (United States)

    Franchi, Matteo; Giacalone, Marilù; Traupe, Ippolito; Rago, Rocco; Baldi, Giacomo; Giunta, Francesco; Forfori, Francesco

    2016-06-01

    Septic shock involves a dysregulation of the immune response to an infection. This may lead to hemodynamic dysfunction and multiple-organ failure. The main aim of this study was to evaluate the effect of coupled plasma filtration adsorption (CPFA) on the hemodynamic profile in patients with septic shock. We retrospectively analyzed data from 21 adult patients admitted to the intensive care unit with a diagnosis of septic shock, comparing data between pre-CPFA and post-CPFA treatment. They received a maximum of 5 cycles of treatment. Coupled plasma filtration adsorption treatment was associated with a significant increase of mean arterial pressure (P septic shock patients, ameliorating organ failure. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Wave stimulated phenomena in inductively coupled magnetized plasmas

    International Nuclear Information System (INIS)

    Shamrai, K P; Shinohara, S; Virko, V F; Slobodyan, V M; Virko, Yu V; Kirichenko, G S

    2005-01-01

    Linear and nonlinear wave phenomena and their influence on the discharge performance are considered in the helicon plasma (HP) and magnetized inductively coupled plasma (MICP). Magnetic field configuration is shown to result in strong variation in the efficiency of plasma production caused by alterations of the character of wave processes rather than by the particle confinement. Effects of magnetic configuration are found to be dominant in operation of the compact HP with permanent magnet. Low frequency turbulence in the megahertz range is revealed to be inherent for both the HP and MICP and to depend strongly on the magnetic configuration. Enhanced axial electric field arising in front of the metal end plate in the HP is argued to be a potential source of the nonlinear effects

  7. Diagnostic studies of ion beam formation in inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, Jenee L. [Iowa State Univ., Ames, IA (United States)

    2015-01-01

    This dissertation describes a variety of studies focused on the plasma and the ion beam in inductively coupled plasma mass spectrometry (ICP-MS). The ability to use ICP-MS for measurements of trace elements in samples requires the analytes to be efficiently ionized. Updated ionization efficiency tables are discussed for ionization temperatures of 6500 K and 7000 K with an electron density of 1 x 1015 cm-3. These values are reflective of the current operating parameters of ICP-MS instruments. Calculations are also discussed for doubly charged (M2+) ion formation, neutral metal oxide (MO) ionization, and metal oxide (MO+) ion dissociation for similar plasma temperature values. Ionization efficiency results for neutral MO molecules in the ICP have not been reported previously.

  8. Equilibrium statistical mechanics of strongly coupled plasmas by numerical simulation

    International Nuclear Information System (INIS)

    DeWitt, H.E.

    1977-01-01

    Numerical experiments using the Monte Carlo method have led to systematic and accurate results for the thermodynamic properties of strongly coupled one-component plasmas and mixtures of two nuclear components. These talks are intended to summarize the results of Monte Carlo simulations from Paris and from Livermore. Simple analytic expressions for the equation of state and other thermodynamic functions have been obtained in which there is a clear distinction between a lattice-like static portion and a thermal portion. The thermal energy for the one-component plasma has a simple power dependence on temperature, (kT)/sup 3 / 4 /, that is identical to Monte Carlo results obtained for strongly coupled fluids governed by repulsive l/r/sup n/ potentials. For two-component plasmas the ion-sphere model is shown to accurately represent the static portion of the energy. Electron screening is included in the Monte Carlo simulations using linear response theory and the Lindhard dielectric function. Free energy expressions have been constructed for one and two component plasmas that allow easy computation of all thermodynamic functions

  9. Measurement of titanium in hip-replacement patients by inductively coupled plasma optical emission spectroscopy.

    Science.gov (United States)

    Harrington, Chris F; McKibbin, Craig; Rahanu, Monika; Langton, David; Taylor, Andrew

    2017-05-01

    Background Patients with metal-on-metal hip replacements require testing for cobalt and chromium. There may also be a need to test for titanium, which is used in the construction of the femoral stem in total hip replacements. It is not possible to use quadrupole inductively coupled plasma mass spectrometry due to interferences. Methods Titanium was measured using inductively coupled plasma optical emission spectroscopy using the emission line at 336.1 nm and Y (internal standard) at 371.0 nm. Internal quality control materials were prepared for blood and serum and concentrations assigned using a sector field-inductively coupled plasma mass spectrometer. A candidate whole blood certified reference material was also evaluated. Results The method had detection and quantitation limits of 0.6 and 1.9 µg/L, respectively. The respective bias (%) and measurement uncertainty ( U) (k = 2) were 3.3% and 2.0 µg/L (serum) and - 1.0% and 1.4 µg/L (whole blood). The respective repeatability and intermediate precision (%) were 5.1% and 10.9% (serum) and 2.4% and 8.6% (whole blood). The concentration of titanium was determined in patients' samples, serum (median = 2.4 µg/L, n = 897) and whole blood (median = 2.4 µg/L, n = 189). Serum is recommended for monitoring titanium in patients, since the concentration is higher than in whole blood and the matrix less problematic. In hip fluid samples, the concentrations were much higher (mean 58.5 µg/L, median 5.1 µg/L, n = 83). Conclusions A method based on inductively coupled plasma optical emission spectroscopy was developed and validated for measuring titanium in clinical samples.

  10. Study of plasma parameters influencing fractionation in laser ablation-inductively coupled plasma-mass spectrometry

    Science.gov (United States)

    Gäckle, M.; Merten, D.

    2010-12-01

    Methods permitting to test the influence of the matrix as well as of its local and temporal distribution on the plasma conditions in laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) are developed. For this purpose, the MS interface is used as plasma probe allowing to investigate the average plasma condition within the ICP zone observed in terms of temporal and spatial distribution of the matrix. Inserted matrix particles, particularly when being atomized and ionized, can cause considerable changes in both electron density and plasma temperature thus influencing the ionization equilibrium of the individual analytes. In this context, the plasma probe covers a region of the plasma for which no local thermodynamic equilibrium can be assumed. The differences in temperature, identified within the region of the plasma observed, amounted up to 3000 K. While in the central region conditions were detected that would not allow efficient atomization and ionization of the matrix, these conditions improve considerably towards the margin of the area observed. Depending on the nature as well as on the temporally and locally variable density of the matrix, this can lead to varying intensity ratios of the analytes and explain fractionation effects. By means of a derived equation it is shown that the deviation of the intensity ratio from the concentration ratio turns out to be more serious the higher the difference of the ionization potential of the analytes observed, the lower the plasma temperature and the higher the matrix concentration within the area observed.

  11. Influence of operating frequency and coupling coefficient on the efficiency of microfabricated inductively coupled plasma sources

    International Nuclear Information System (INIS)

    Iza, F; Hopwood, J

    2002-01-01

    Microfabricated inductively coupled plasma (mICP) generators, operating at 690 and 818 MHz, have been constructed and characterized. The mICP consists of a single-turn coil that is 5 mm in diameter and a microfabricated matching network. Ion densities of ∼9x10 10 cm -3 in argon at 400 mTorr consuming only 1 W were obtained. This ion density is three times larger than previous mICP sources under the same conditions. The influence of the frequency of operation and the coupling coefficient on the power efficiency has also been studied. Contrary to what was observed in former generations of mICP sources operating at lower frequencies, the efficiency of the new mICP sources decreases as the frequency increases. A model that incorporates the electron inertia, the power dependence of the plasma resistance and the frequency dependence of the coil resistance agrees with the new experimental results as well as with the results of previous mICP sources. It was also observed that bringing the coil closer to the plasma increases the coupling coefficient of the ICP sources and thereby improves the efficiency of the device. The improvement in efficiency, however, is limited by the non-scalable plasma sheath width near the coil

  12. Effect of capacitive coupling in a miniature inductively coupled plasma source

    International Nuclear Information System (INIS)

    Takao, Yoshinori; Eriguchi, Koji; Ono, Kouichi

    2012-01-01

    Two-dimensional axisymmetric particle-in-cell simulations with a Monte Carlo collision algorithm (PIC-MCC) have been conducted to investigate the effect of capacitive coupling in a miniature inductively coupled plasma source (mICP) by using two models: an inductive model and a hybrid model. The mICP is 3 mm in radius and 6 mm in height with a three-turn planar coil, where argon plasma is sustained. In the inductive model, the coil is assumed to be electrostatically shielded, and thus the discharge is purely inductive coupling. In the hybrid model, we assume that the different turns of the coil act like electrodes in capacitive discharge to include the effect of capacitive coupling. The voltage applied to these electrodes decreases linearly from the powered end of the coil towards the grounded end. The numerical analysis has been performed for rf frequencies in the range of 100-1000 MHz, and the power absorbed by the plasma in the range of 5-50 mW at a fixed pressure of 500 mTorr. The PIC-MCC results show that potential oscillations at the plasma-dielectric interface are not negligible, and thus the major component of the absorbed power is caused by the axial motion of electrons in the hybrid model, although almost all of the power absorption is due to the azimuthal motion of electrons in the inductive model. The effect of capacitive coupling is more significant at lower rf frequencies and at higher absorbed powers under the calculation conditions examined. Moreover, much less coil currents are required in the hybrid model.

  13. Effect of single aerosol droplets on plasma impedance in the inductively coupled plasma

    International Nuclear Information System (INIS)

    Chan, George C.-Y.; Zhu, Zhenli; Hieftje, Gary M.

    2012-01-01

    The impedance of an inductively coupled plasma was indirectly monitored by two different means—through a RF-probe coil placed inside the torch housing and from tapping the phase-detector signal of the impedance-matching network. During single-droplet introduction, temporal spikes in both the RF-probe coil and the phase-detector signals were readily observed, indicating a momentary change in plasma impedance. The changes in plasma impedance were found to be due solely to plasma perturbation by droplet introduction, and not to an artifact caused by imperfect automatic impedance matching. The temporal changes in plasma impedance were found to be directly proportional to the temporally integrated atomic emission of hydrogen, which is assumed in turn to be directly proportional to the volume of the introduced droplet. A small satellite droplet, with an estimated diameter of 27 μm (i.e., ∼ 10 pL in volume), caused a readily measurable change in plasma impedance. By assuming that the change in RF-probe voltage is directly proportional to the variation in RF power delivered by the load coil, the instantaneous power change coupled to the plasma during single-droplet introduction was estimated. Typical increases in peak RF power and total energy coupled to the plasma, for a single 50-μm droplet introduction, were thereby estimated to be around 8 to 11 W and 0.03 to 0.04 J, respectively. This impedance change was also exploited as a trigger to signal the droplet-introduction event into the plasma. This trigger signal was obtained through a combination of the RF-probe and the phase-detector signals and offered typical jitter from 1 to 2 ms. With the proper choice of a trigger threshold, no trigger misfire resulted and the achievable efficiencies of the trigger signal were 99.95, 97.18 and 74.33% for plasma forward power levels of 900, 1200, and 1500 W, respectively. The baseline noise on the RF-probe coil and the phase-detector signals, which increase with plasma forward

  14. Thermodynamics and instabilities of a strongly coupled anisotropic plasma

    Science.gov (United States)

    Mateos, David; Trancanelli, Diego

    2011-07-01

    We extend our analysis of a IIB supergravity solution dual to a spatially anisotropic finite-temperature mathcal{N} = 4 super Yang-Mills plasma. The solution is static, possesses an anisotropic horizon, and is completely regular. The full geometry can be viewed as a renormalization group flow from an AdS geometry in the ultraviolet to a Lifshitz-like geometry in the infrared. The anisotropy can be equivalently understood as resulting from a position-dependent θ-term or from a non-zero number density of dissolved D7-branes. The holographic stress tensor is conserved and anisotropic. The presence of a conformal anomaly plays an important role in the thermodynamics. The phase diagram exhibits homogeneous and inhomogeneous (i.e. mixed) phases. In some regions the homogeneous phase displays instabilities reminiscent of those of weakly coupled plasmas. We comment on similarities with QCD at finite baryon density and with the phenomenon of cavitation.

  15. Prostaglandins release plasma 'reciprocal coupling factor' in anaesthetized rats.

    Science.gov (United States)

    Hoult, J. R.; Moore, P. K.

    1981-01-01

    1. Prostaglandins E1, E2, I2 and endoperoxide analogue U46619 injected intra-arterially (i.a.) into anaesthetized rats at 2 micrograms/kg caused a substantial increase within 60 min of the plasma activity of prostaglandin 'reciprocal coupling factor' (RCF). RCF is the provisional name for the component(s) of plasma which inhibit microsomal prostaglandin synthesis and enhance cytosolic prostaglandin breakdown. 2. RCF is not released by inactive metabolite 13,14-dihydro-15-keto prostaglandin E2 (10 micrograms/kg, i.a.) or acetylcholine or histamine (2 micrograms/kg, i.a.). 3. We suggest that release by prostaglandins of RCF would provide the basis in vivo for a negative feedback mechanism controlling the activity of the prostaglandin system. PMID:7032632

  16. Magnetohydrodynamic stability of tokamak plasmas with poloidal mode coupling

    International Nuclear Information System (INIS)

    Shigueoka, H.; Sakanaka, P.H.

    1987-01-01

    The stability behavior with respect to internal modes is examined for a class of tokamak equilibria with non-circular cross sections. The surfaces of the constant poloidal magnetic flux ψ (R,Z) are obtained numerically by solving the Grad-Shafranov's equation with a specified shape for the outmost plasma surface. The equation of motion for ideal MHD stability is written in a ortogonal coordinate system (ψ, χ, φ). Th e stability analysis is performance numerically in a truncated set of coupled m (poloidal wave number) equations. The calculations involve no approximations, and so all parameters of the equilibrium solution can be arbitrarily varied. (author) [pt

  17. On the heterotic effective action at one-loop, gauge couplings and the gravitational sector

    CERN Document Server

    Kiritsis, E.; Petropoulos, P.M.; Rizos, J.

    1996-01-01

    We present in detail the procedure for calculating the heterotic one-loop effective action. We focus on gravitational and gauge couplings. We show that the two-derivative couplings of the gravitational sector are not renormalized at one loop when the ground state is supersymmetric. Arguments are presented that this non-renormalization theorem persists to all orders in perturbation theory. Arguments are presented that this non-renormalization theorem persists to all orders in perturbation theory. We also derive the full one-loop correction to the gauge coupling. For a class of N=2 ground states, namely those that are obtained by toroidal compactification to four dimensions of generic six-dimensional N=1 models, we give an explicit formula for the gauge-group independent thresholds, and show that these are equal within the whole family.

  18. Determination of the profit rate of plasma treated production in the food sector

    Science.gov (United States)

    Gok, Elif Ceren; Uygun, Emre; Eren, Esin; Oksuz, Lutfi; Uygun Oksuz, Aysegul

    2017-10-01

    Recently, plasma is one of an emerging, green processing technologies used for diverse applications especially food industry. Plasma treatment proposes diverse opportunities in food industry such as surface decontamination, modification of surface properties and improvement in mass transfer with respect for foods and food-related compounds. Sometimes manufacturers use chemical treatment to demolish pathogenic flora, but its capabilities are rather limited. New methods of food sterilization consisting of ionizing radiation, exposure to magnetic fields, high-power ultrasonic treatment are needed expensive equipment or have not yet been developed for industrial use. Plasma could be used for the above mentioned reasons. In this study, the profit rate of plasma treated production in food sector was calculated.

  19. Modeling viscosity and diffusion of plasma mixtures across coupling regimes

    Science.gov (United States)

    Arnault, Philippe

    2014-10-01

    Viscosity and diffusion of plasma for pure elements and multicomponent mixtures are modeled from the high-temperature low-density weakly coupled regime to the low-temperature high-density strongly coupled regime. Thanks to an atom in jellium modeling, the effect of electron screening on the ion-ion interaction is incorporated through a self-consistent definition of the ionization. This defines an effective One Component Plasma, or an effective Binary Ionic Mixture, that is representative of the strength of the interaction. For the viscosity and the interdiffusion of mixtures, approximate kinetic expressions are supplemented by mixing laws applied to the excess viscosity and self-diffusion of pure elements. The comparisons with classical and quantum molecular dynamics results reveal deviations in the range 20--40% on average with almost no predictions further than a factor of 2 over many decades of variation. Applications in the inertial confinement fusion context could help in predicting the growth of hydrodynamic instabilities.

  20. Transient plasma potential in pulsed dual frequency inductively coupled plasmas and effect of substrate biasing

    Directory of Open Access Journals (Sweden)

    Anurag Mishra

    2016-09-01

    Full Text Available An electron emitting probe in saturated floating potential mode has been used to investigate the temporal evolution of plasma potential and the effect of substrate RF biasing on it for pulsed dual frequency (2 MHz/13.56 MHz inductively coupled plasma (ICP source. The low frequency power (P2MHz has been pulsed at 1 KHz and a duty ratio of 50%, while high frequency power (P13.56MHz has been used in continuous mode. The substrate has been biased with a separate bias power at (P12.56MHz Argon has been used as a discharge gas. During the ICP power pulsing, three distinct regions in a typical plasma potential profile, have been identified as ‘initial overshoot’, pulse ‘on-phase’ and pulse ‘off-phase’. It has been found out that the RF biasing of the substrate significantly modulates the temporal evolution of the plasma potential. During the initial overshoot, plasma potential decreases with increasing RF biasing of the substrate, however it increases with increasing substrate biasing for pulse ‘on-phase’ and ‘off-phase’. An interesting structure in plasma potential profile has also been observed when the substrate bias is applied and its evolution depends upon the magnitude of bias power. The reason of the evolution of this structure may be the ambipolar diffusion of electron and its dependence on bias power.

  1. Low-pressure water-cooled inductively coupled plasma torch

    Science.gov (United States)

    Seliskar, Carl J.; Warner, David K.

    1988-12-27

    An inductively coupled plasma torch is provided which comprises an inner tube, including a sample injection port to which the sample to be tested is supplied and comprising an enlarged central portion in which the plasma flame is confined; an outer tube surrounding the inner tube and containing water therein for cooling the inner tube, the outer tube including a water inlet port to which water is supplied and a water outlet port spaced from the water inlet port and from which water is removed after flowing through the outer tube; and an r.f. induction coil for inducing the plasma in the gas passing into the tube through the sample injection port. The sample injection port comprises a capillary tube including a reduced diameter orifice, projecting into the lower end of the inner tube. The water inlet is located at the lower end of the outer tube and the r.f. heating coil is disposed around the outer tube above and adjacent to the water inlet.

  2. Matrix effects in inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiaoshan [Iowa State Univ., Ames, IA (United States)

    1995-07-07

    The inductively coupled plasma is an electrodeless discharge in a gas (usually Ar) at atmospheric pressure. Radio frequency energy generated by a RF power source is inductively coupled to the plasma gas through a water cooled load coil. In ICP-MS the "Fassel" TAX quartz torch commonly used in emission is mounted horizontally. The sample aerosol is introduced into the central flow, where the gas kinetic temperature is about 5000 K. The aerosol is vaporized, atomized, excited and ionized in the plasma, and the ions are subsequently extracted through two metal apertures (sampler and skimmer) into the mass spectrometer. In ICP-MS, the matrix effects, or non-spectroscopic interferences, can be defined as the type of interferences caused by dissolved concomitant salt ions in the solution. Matrix effects can be divided into two categories: (1) signal drift due to the deposition of solids on the sampling apertures; and/or (2) signal suppression or enhancement by the presence of the dissolved salts. The first category is now reasonably understood. The dissolved salts, especially refractory oxides, tend to deposit on the cool tip of the sampling cone. The clogging of the orifices reduces the ion flow into the ICP-MS, lowers the pressure in the first stage of ICP-MS, and enhances the level of metal oxide ions. Because the extent of the clogging increases with the time, the signal drifts down. Even at the very early stage of the development of ICP-MS, matrix effects had been observed. Houk et al. found out that the ICP-MS was not tolerant to solutions containing significant amounts of dissolved solids.

  3. Matrix effects in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Chen, Xiaoshan.

    1995-01-01

    The inductively coupled plasma is an electrodeless discharge in a gas (usually Ar) at atmospheric pressure. Radio frequency energy generated by a RF power source is inductively coupled to the plasma gas through a water cooled load coil. In ICP-MS the open-quotes Fasselclose quotes TAX quartz torch commonly used in emission is mounted horizontally. The sample aerosol is introduced into the central flow, where the gas kinetic temperature is about 5000 K. The aerosol is vaporized, atomized, excited and ionized in the plasma, and the ions are subsequently extracted through two metal apertures (sampler and skimmer) into the mass spectrometer. In ICP-MS, the matrix effects, or non-spectroscopic interferences, can be defined as the type of interferences caused by dissolved concomitant salt ions in the solution. Matrix effects can be divided into two categories: (1) signal drift due to the deposition of solids on the sampling apertures; and/or (2) signal suppression or enhancement by the presence of the dissolved salts. The first category is now reasonably understood. The dissolved salts, especially refractory oxides, tend to deposit on the cool tip of the sampling cone. The clogging of the orifices reduces the ion flow into the ICP-MS, lowers the pressure in the first stage of ICP-MS, and enhances the level of metal oxide ions. Because the extent of the clogging increases with the time, the signal drifts down. Even at the very early stage of the development of ICP-MS, matrix effects had been observed. Houk et al. found out that the ICP-MS was not tolerant to solutions containing significant amounts of dissolved solids

  4. ICRF plasma production in Tore Supra: analysis of antenna coupling and plasma properties

    International Nuclear Information System (INIS)

    Beaumont, B.; Becoulet, A.; Lyssoivan, A.

    1999-01-01

    A study of RF plasma production frequency range ω. 2ω ci has been undertaken on Tore Supra taking into account antenna coupling predictions of theory and the TEXTOR-94 database. Two scenarios for RF discharges have been tested (fixed frequency of the RF generator): operation with pure toroidal magnetic field, at standard and lower B T and operation in the magnetic configuration with a small vertical (B V ) field superimposed on B T (B V T ). (authors)

  5. Efficient laser-overdense plasma coupling via surface plasma waves and steady magnetic field generation

    Energy Technology Data Exchange (ETDEWEB)

    Bigongiari, A. [CEA/DSM/LSI, CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); TIPS/LULI, Universite Paris 6, CNRS, CEA, Ecole Polytechnique, 3, rue Galilee 94200, Ivry-sur-Seine (France); Raynaud, M. [CEA/DSM/LSI, CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); Riconda, C. [TIPS/LULI, Universite Paris 6, CNRS, CEA, Ecole Polytechnique, 3, rue Galilee 94200, Ivry-sur-Seine (France); Heron, A. [CPHT, CNRS, Ecole Polytechnique, 91128 Palaiseau Cedex (France); Macchi, A. [Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica (CNR/INO), Dipartimento di Fisica ' ' E. Fermi' ' , Largo B. Pontecorvo 3, 56127 Pisa (Italy)

    2011-10-15

    The efficiency of laser overdense plasma coupling via surface plasma wave excitation is investigated. Two-dimensional particle-in-cell simulations are performed over a wide range of laser pulse intensity from 10{sup 15} to 10{sup 20} W cm{sup -2}{mu}m{sup 2} with electron density ranging from 25 to 100n{sub c} to describe the laser interaction with a grating target where a surface plasma wave excitation condition is fulfilled. The numerical studies confirm an efficient coupling with an enhancement of the laser absorption up to 75%. The simulations also show the presence of a localized, quasi-static magnetic field at the plasma surface. Two interaction regimes are identified for low (I{lambda}{sup 2} < 10{sup 17} W cm{sup -2}{mu}m{sup 2}) and high (I{lambda}{sup 2} > 10{sup 17} W cm{sup -2}{mu}m{sup 2}) laser pulse intensities. At ''relativistic'' laser intensity, steady magnetic fields as high as {approx}580 MG {mu}m/{lambda}{sub 0} at 7 x 10{sup 19} W cm{sup -2}{mu}m{sup 2} are obtained in the simulations.

  6. Electromagneto-mechanical coupling analysis of a test module in J-TEXT Tokamak during plasma disruption

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Haijie; Yuan, Zhensheng; Yuan, Hongwei; Pei, Cuixiang [State Key Laboratory for Strength and Vibration of Mechanical Structures, Shanxi Engineering Research Center for NDT and Structural Integrity Evaluation Xi’an Jiaotong University, Xi’an 710049 (China); Chen, Zhenmao, E-mail: chenzm@mail.xjtu.edu.cn [State Key Laboratory for Strength and Vibration of Mechanical Structures, Shanxi Engineering Research Center for NDT and Structural Integrity Evaluation Xi’an Jiaotong University, Xi’an 710049 (China); Yang, Jinhong; Wang, Weihua [Institute of Applied Physics of AOA, Hefei 230031 (China)

    2016-11-01

    In this paper, the dynamic response during plasma disruption of a test blanket module in vacuum vessel (VV) of the Joint TEXT (J-TEXT), which is an experimental Tokamak device with iron core, was simulated by applying a program developed by authors on the ANSYS platform using its parametric design language (APDL). The moving coordinate method as well as the load transfer and sequential coupling strategy were adopted to cope with the electromagneto-mechanical coupling effect. To establish the numerical model, the influence of the iron core on the eddy current and electromagnetic (EM) force during disruption was numerically investigated at first and the influence was found not significant. Together with the geometrical features of the J-TEXT Tokamak structure, 180° sector models without magnetic core were finally established for the EM field and the structural response simulations. To obtain the source plasma current, the plasma current evolution during disruption was simulated by using the Tokamak Simulation Code (TSC). With the numerical models and the source plasma current, the dynamic response of both the VV structure and the test module were calculated. The numerical results show that the maximum stress of the test module is in safe range, and the magnetic damping effect can weaken vibration of the test module. In addition, simulation without considering the coupling effect was carried out, which shows that the influence of coupling effect is not significant for the peak stress of the J-TEXT disruption problem.

  7. Quantification of {sup 232}Th, {sup 234}U, {sup 235}U and {sup 238}U in river mollusks by magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS); Cuantificacion de {sup 232}Th, {sup 234}U, {sup 235}U y {sup 238}U en moluscos de rios por espectrometria de masas de sector magnetico con fuente de plasma acoplado inductivamente (ICP-SFMS)

    Energy Technology Data Exchange (ETDEWEB)

    Arevalo R, D. L.; Hernandez M, H.; Romero G, E. T.; Lara A, N. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Alfaro de la T, M. C., E-mail: arevalo0591@hotmail.com [Universidad Autonoma de San Luis Potosi, Dr. Salvador Nava s/n, Zona Universitaria, 78290 San Luis Potosi, SLP (Mexico)

    2016-09-15

    The present work deals with the methodology established for the quantification of {sup 232}Th, {sup 234}U, {sup 238}U and {sup 235}U in the shell of gastropod mollusks collected in the rivers Valles, Coy and Axtla of San Luis Potosi, Mexico, which belong to the Panuco River basin; these rivers have as main source of pollution the discharge of municipal sewage, waste from small industries, agricultural and cattle residues and from natural sources. Conventional methods for measuring radio-nuclides are confronted with certain conditions related to the requirement in measurement, basically in the characterization that is related to the concepts of precision and accuracy. The analysis of the gastropod mollusk shell was performed by the Icp-SFMS technique; the main advantages of this technique lie in the isotope quantification capacity, the high precision and the low limits of detection, in this study are very important because these elements are in concentrations between ppb and ppt. This technique allowed the analysis of the samples having a complex matrix by the presence CaCO{sub 3} minimizing the interferences thanks to the ionization efficiency of the Ar plasma. For the species Pachychilus monachus were found concentrations of {sup 232}Th of 0.16-5.37 μg/g and of total U of 0.101-4.081 μg/g being this species where the highest values of total U were found. For Thiara (melanoids) tuberculata the lowest values were found among the different species ({sup 232}Th 0.61-3.61 μg/g and total U 0.006-0.042 μg/g), for Pachychilus suturalis, values of {sup 232}Th of 0.58-6.4 μg/g and for Pachychilus sp. were found between 0.26-7.62 μg/g and for total U values between 0.28-3.33 μg/g. The method offers several advantages: speed, good precision, low values of quantification limits and high sensitivity in the measurement of radio-nuclides and heavy metals. (Author)

  8. Computer simulations of an oxygen inductively coupled plasma used for plasma-assisted atomic layer deposition

    International Nuclear Information System (INIS)

    Tinck, S; Bogaerts, A

    2011-01-01

    In this paper, an O 2 inductively coupled plasma used for plasma enhanced atomic layer deposition of Al 2 O 3 thin films is investigated by means of modeling. This work intends to provide more information about basic plasma properties such as species densities and species fluxes to the substrate as a function of power and pressure, which might be hard to measure experimentally. For this purpose, a hybrid model developed by Kushner et al is applied to calculate the plasma characteristics in the reactor volume for different chamber pressures ranging from 1 to 10 mTorr and different coil powers ranging from 50 to 500 W. Density profiles of the various oxygen containing plasma species are reported as well as fluxes to the substrate under various operating conditions. Furthermore, different orientations of the substrate, which can be placed vertically or horizontally in the reactor, are taken into account. In addition, special attention is paid to the recombination process of atomic oxygen on the different reactor walls under the stated operating conditions. From this work it can be concluded that the plasma properties change significantly in different locations of the reactor. The plasma density near the cylindrical coil is high, while it is almost negligible in the neighborhood of the substrate. Ion and excited species fluxes to the substrate are found to be very low and negligible. Finally, the orientation of the substrate has a minor effect on the flux of O 2 , while it has a significant effect on the flux of O. In the horizontal configuration, the flux of atomic oxygen can be up to one order of magnitude lower than in the vertical configuration.

  9. Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, Douglas C., E-mail: douglas.baxter@alsglobal.com [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Faarinen, Mikko [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Osterlund, Helene; Rodushkin, Ilia [ALS Scandinavia AB, Aurorum 10, 977 75 Lulea (Sweden); Division of Geosciences, Lulea University of Technology, 977 87 Lulea (Sweden); Christensen, Morten [ALS Scandinavia AB, Maskinvaegen 2, 183 53 Taeby (Sweden)

    2011-09-09

    Highlights: {center_dot} We determine methylmercury in serum and plasma using isotope dilution calibration. {center_dot} Separation by gas chromatography and detection by inductively coupled plasma mass spectrometry. {center_dot} Data for 50 specimens provides first reference range for methylmercury in serum. {center_dot} Serum samples shown to be stable for 11 months in refrigerator. - Abstract: A method for the determination of methylmercury in plasma and serum samples was developed. The method uses isotope dilution with {sup 198}Hg-labeled methylmercury, extraction into dichloromethane, back-extraction into water, aqueous-phase ethylation, purge and trap collection, thermal desorption, separation by gas chromatography, and mercury isotope specific detection by inductively coupled plasma mass spectrometry. By spiking 2 mL sample with 1.2 ng tracer, measurements in a concentration interval of (0.007-2.9) {mu}g L{sup -1} could be performed with uncertainty amplification factors <2. A limit of quantification of 0.03 {mu}g L{sup -1} was estimated at 10 times the standard deviation of concentrations measured in preparation blanks. Within- and between-run relative standard deviations were <10% at added concentration levels of 0.14 {mu}g L{sup -1}, 0.35 {mu}g L{sup -1} and 2.8 {mu}g L{sup -1}, with recoveries in the range 82-110%. Application of the method to 50 plasma/serum samples yielded a median (mean; range) concentration of methylmercury of 0.081 (0.091; <0.03-0.19) {mu}g L{sup -1}. This is the first time methylmercury has been directly measured in this kind of specimen, and is therefore the first estimate of a reference range.

  10. Coupled tearing modes in plasmas with differential rotation

    International Nuclear Information System (INIS)

    Dewar, R.L.; Persson, M.

    1993-08-01

    The global asymptotic matching equations for multiple coupled resistive modes of arbitrary parity in a cylindrical plasma are derived. Three different variational principles are given for the outer region matching data, while the inner-region analysis features a careful treatment of the symmetry-breaking effect of a gradient in the equilibrium current for a zero-β slab model. It is concluded that the usual constant-ψ result remains valid and constrains the matrix matching formalism. The dispersion relation is compared with initial value calculations of a double tearing mode when there are small relative rotation velocities between the rational surfaces. In treating differential rotation within the asymptotic matching formalism, flow is ignored in the outer region and is assumed to affect the inner response solely through a Doppler shift. It is shown that the relative rotation can have a strong stabilizing effect by making all but one rational surface effectively ideal. 40 refs., 6 figs

  11. A new nebulizer for inductively coupled plasma spectrometry

    International Nuclear Information System (INIS)

    Rademeyer, C.D.; Collins, C.; Butler, L.; Human, C.

    1989-01-01

    A nebulizer for use in Inductively Coupled Plasma Emission Spectroscopy (ICP-ES) is designed. An unusual concept is used to generate the aerosol. The system is mechanically reliable, relatively simple and cheap to construct compared to the currently available commercial systems. The effect of geometrical design parameters (e.g. the droplet size mass distribution of the aerosol particles) on performance of the system is presented. The analytical merit of the newly designed system is determined by measuring its analytical performance. Detection limits and analytical range are measured for Cu, Ag, Au, Pt, Pb, Cd, V, Fe, Mn, Mo, B, Se and Zn. These values are compared with detection limits and analytical ranges obtained with commercial systems. The persistence of memory effects is found to be the major disadvantage of the system. Results are presented showing these effects and possible ways to eliminate them. (author)

  12. Beam-plasma coupling physics in support of active experiments

    Science.gov (United States)

    Yakymenko, K.; Delzanno, G. L.; Roytershteyn, V.

    2017-12-01

    The recent development of compact relativistic accelerators might open up a new era of active experiments in space, driven by important scientific and national security applications. Examples include using electron beams to trace magnetic field lines and establish causality between physical processes occurring in the magnetosphere and those in the ionosphere. Another example is the use of electron beams to trigger waves in the near-Earth environment. Waves could induce pitch-angle scattering and precipitation of energetic electrons, acting as an effective radiation belt remediation scheme. In this work, we revisit the coupling between an electron beam and a magnetized plasma in the framework of linear cold-plasma theory. We show that coupling can occur through two different regimes. In the first, a non-relativistic beam radiates through whistler waves. This is well known, and was in fact the focus of many rockets and space-shuttle campaigns aimed at demonstrating whistler emissions in the eighties. In the second regime, the beam radiates through extraordinary (R-X) modes. Nonlinear simulations with a highly-accurate Vlasov code support the theoretical results qualitatively and demonstrate that the radiated power through R-X modes can be much larger than in the whistler regime. Test-particle simulations in the wave electromagnetic field will also be presented to assess the efficiency of these waves in inducing pitch-angle scattering via wave-particle interactions. Finally, the implications of these results for a rocket active experiment in the ionosphere and for a radiation belt remediation scheme will be discussed.

  13. Effect of electron thermal motion on plasma heating in a magnetized inductively coupled plasma

    International Nuclear Information System (INIS)

    Aman-ur-Rehman; Pu Yikang

    2007-01-01

    Power absorbed inside the magnetized inductively coupled plasma (MICP) is calculated using three different warm MICP models and is then compared with the result of the cold MICP model. The comparison shows that in the propagating region (ω e vertical bar), under the cavity resonance conditions, warm plasma heating S warm is significantly less than the cold plasma heating S cold , unless the distance traveled by the electrons due to their thermal motion, during the effective wave period, becomes significantly less than the wavelength of the cavity wave. Furthermore, in the propagating region, when ω≅ vertical bar Ω e vertical bar, there appears a valley on the plot of η(ω)=S warm /S cold versus ω showing the negative effect of electron thermal motion on plasma heating. This valley widens and gets smoother with an increase in the plasma length. In the nonpropagating region (ω> vertical bar Ω e vertical bar), the maximum value of η(ω) exists when ω- vertical bar Ω e vertical bar ≅v th /δ, showing that, in the presence of the external magnetic field, the thermal motion of the electrons leads to a Doppler shift of the frequencies, at which collisionless heating is the dominant mode of electron heating. Furthermore, in the nonpropagating region, when ω≅ vertical bar Ω e vertical bar, the skin depth of the right circularly polarized electric field decreases with magnetic field. This decrease in the skin depth results in an increase of collisionless heating under the Doppler-shifted wave particle resonant condition of ω- vertical bar Ω e vertical bar ≅v th /δ. It is also observed that, for large plasma length, the results of all the three warm MICP models are consistent with each other

  14. The Hematocrit Affects the Volume of Plasma Treated With Coupled Plasma Filtration and Adsorption With Predilution.

    Science.gov (United States)

    Finazzi, Stefano; Garbero, Elena; Trussardi, Giampietro; Bertolini, Guido

    2017-05-01

    Coupled plasma filtration and adsorption (CPFA) is an extracorporeal blood purification technique proposed for the treatment of septic-shock. By removing pro- and anti-inflammatory mediators from plasma, CPFA is supposed to have a therapeutic effect on the abnormal inflammatory response seen in this condition. Recently, blood predilution with citrate solution has been adopted to prevent clotting in the CPFA circuit-one of the main problems of the technique. Taking into account the patient's hematocrit, we worked out a formula for the volume of plasma effectively treated by CPFA after predilution. Neglecting this effect, as is commonly done, introduces significant distortions in the estimation of the volume, possibly causing under-treatment. The distortion is stronger when the hematocrit and the predilution fraction are large and weaker when both values shrink. By correctly indicating the daily dose of plasma adsorption received by patients, this formula is essential for assessing the therapeutic efficacy of CPFA and, subsequently, establishing its optimal doses. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. Microwave power coupling in a surface wave excited plasma

    Directory of Open Access Journals (Sweden)

    Satyananda Kar

    2015-01-01

    Full Text Available In recent decades, different types of plasma sources have been used for various types of plasma processing, such as, etching and thin film deposition. The critical parameter for effective plasma processing is high plasma density. One type of high density plasma source is Microwave sheath-Voltage combination Plasma (MVP. In the present investigation, a better design of MVP source is reported, in which over-dense plasma is generated for low input microwave powers. The results indicate that the length of plasma column increases significantly with increase in input microwave power.

  16. New methodical and instrumental developments in laser ablation inductively coupled plasma mass spectrometry1

    Science.gov (United States)

    Hoffmann, E.; Lüdke, C.; Skole, J.; Stephanowitz, H.; Wollbrandt, J.; Becker, W.

    2002-10-01

    Many tasks in bulk analysis, micro analysis and depth profile analysis can be solved advantageously by laser ablation inductively coupled plasma mass spectrometry (Laser ICP-MS) in particular, when both the chemical and elemental distributions in the sample are to be determined. However, the analyst has to take into account that the analytical precision and accuracy of the Laser ICP-MS is influenced decisively by signal standardization, the homogeneity of the samples as well as calibration standards and the mass-spectrometric measuring mode, which is usually sequential when performed with scanning mass spectrometers such as quadrupol- or sector-based instruments. Using the ablated mass as standard, an excellent level of the analytical precision and accuracy (relative standard deviation R.S.D.ASIC) was developed, which permits a time resolution of 1 ns. The analytical performance of the TOF when used in combination with an ICP is demonstrated in terms of resolution, ion extraction rate, detection limits and dynamic range. The determination of 39K + and 40Ca + at trace level can be realized in a cool plasma condition (high central gas flow) only with a small interference by 40Ar +. Detection limits of 23 elements were measured with typical values in the lower nanograms per liter range. The ion extraction rates, measured for a sample mass of 1 ng in terms of counts per second divided by the relative isotope abundance, are one order of magnitude higher than those obtained with a quadrupol-based instrument.

  17. Analysis of plasma coupling with the prototype DIII-D ICRF antenna

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, P.M.; Hoffman, D.J.; Bigelow, T.S.; Baity, F.W.; Gardner, W.L.; Mayberry, M.J.; Rothe, K.E.

    1988-01-01

    Coupling to plasma in the H-mode is essential to the success of future ignited machines such as CIT. To ascertain voltage and current requirements for high-power second harmonic heating (2 MW in a 35- by 50-cm port), coupling to the DIII-D tokamak with a prototype compact loop antenna has been measured. The results show good loading for L-mode and limiter plasmas, but coupling 2 MW to an H-mode plasma demands voltages and currents near the limit of present technology. We report the technological analysis and progress that allow coupling of these power densities. 5 refs., 4 figs.

  18. Analysis of plasma coupling with the prototype DIII-D ICRF antenna

    International Nuclear Information System (INIS)

    Ryan, P.M.; Hoffman, D.J.; Bigelow, T.S.; Baity, F.W.; Gardner, W.L.; Mayberry, M.J.; Rothe, K.E.

    1988-01-01

    Coupling to plasma in the H-mode is essential to the success of future ignited machines such as CIT. To ascertain voltage and current requirements for high-power second harmonic heating (2 MW in a 35- by 50-cm port), coupling to the DIII-D tokamak with a prototype compact loop antenna has been measured. The results show good loading for L-mode and limiter plasmas, but coupling 2 MW to an H-mode plasma demands voltages and currents near the limit of present technology. We report the technological analysis and progress that allow coupling of these power densities. 5 refs., 4 figs

  19. -3000 V dc bias Ti oxidation by inductively coupled plasma

    International Nuclear Information System (INIS)

    Valencia-Alvarado, R; Lopez-Callejas, R; Barocio, S R; Mercado-Cabrera, A; Pena-Eguiluz, R; Munoz-Castro, A E; De la Piedad-Beneitez, A; De la Rosa-Vazquez, J

    2008-01-01

    Broadening the outer oxidized layer of titanium by means of plasmas commands considerable interest in the biomedical research area due to its potential in human biocompatibility enhancement. Some early results of titanium substrate superficial oxidation experiments which have been conducted in a cylindrical vessel inductively coupled to a 13.56 MHz RF generator with a 500 W output are presented. The oxidation process was carried out in a 20 % oxygen and 80 % argon mixture at work pressures in the 5x10 -3 -1 mbar range, while the samples were dc biased down to -3000 V. The substrate temperature appears to be directly dependent on this voltage, reaching 685 deg. C at the maximum bias when a diffusive oxidation process gives rise to the TiO 2 and α-TiO rutile phases. These were characterized by means of x-ray diffraction and scanning electron microscopy revealing atomic percentage concentrations of oxygen, with respect to those of titanium, between 68 and 13 at.%. The optimum modified layer depth reached 5 μm at a 5x10 -2 mbar work pressure.

  20. Experimental study of reduced size inductively coupled plasma torches

    International Nuclear Information System (INIS)

    Allemand, C.D.; Barnes, R.M.; Wohlers, C.C.

    1979-01-01

    A new design of inductively coupled plasma torches embodies smooth contours and sharp edges to achieve laminar flow for sample confinement and an optimized ratio of the diameter of the two outer tubes to ease maintenance and operation of the discharge. Results are presented for a 13-mm and a 9-mm version of the new configuration and are compared to data for a standard 8-mm version. For spectrochemical analyses, the detection limits obtained with the 13-mm torch were about the same as obtained with the standard 18-mm and those obtained with the 9-mm torch were similar or poorer. The theoretical prediction that smaller torches require higher magnetic flux densities was confirmed quantitatively by operation of the 9-mm torch. The 13-mm torch consumed less power and gas than the standard 18-mm torch at equivelent analytical performance level. The torches were compared for the determination of Al, As, Ba, Ca, Cd, Co, Cr(II), Cr(I), Cu, Fe, K, Mg, Mn, Mo, P, Pb, Sn, Sr, Ti, U, V, and Zn

  1. Effect of random charge fluctuation on strongly coupled dusty Plasma

    Science.gov (United States)

    Issaad, M.; Rouiguia, L.; Djebli, M.

    2008-09-01

    Modeling the interaction between particles is an open issue in dusty plasma. We dealt with strongly coupled dust particles in two dimensional confined system. For small number of clusters, we investigate the effect of random charge fluctuation on background configuration. The study is conducted for a short rang as well as a long rang potential interaction. Numerical simulation is performed using Monte-Carlo simulation in the presence of parabolic confinement and at low temperature. We have studied the background configurations for a dust particles with constant charge and in the presence of random charge fluctuation due to the discrete nature of charge carriers. The latter is studied for a positively charged dust when the dominant charging process is due to photo-emission from the dust surface. It is found, for small classical cluster consisting of small number of particles, short rang potential gives the same result as long rang one. It is also found that the random charge fluctuation affect the background configurations.

  2. Uranium quantification in semen by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Todorov, Todor; Ejnik, John W.; Guandalini, Gustavo S.; Xu, Hanna; Hoover, Dennis; Anderson, Larry W.; Squibb, Katherine; McDiarmid, Melissa A.; Centeno, Jose A.

    2013-01-01

    In this study we report uranium analysis for human semen samples. Uranium quantification was performed by inductively coupled plasma mass spectrometry. No additives, such as chymotrypsin or bovine serum albumin, were used for semen liquefaction, as they showed significant uranium content. For method validation we spiked 2 g aliquots of pooled control semen at three different levels of uranium: low at 5 pg/g, medium at 50 pg/g, and high at 1000 pg/g. The detection limit was determined to be 0.8 pg/g uranium in human semen. The data reproduced within 1.4–7% RSD and spike recoveries were 97–100%. The uranium level of the unspiked, pooled control semen was 2.9 pg/g of semen (n = 10). In addition six semen samples from a cohort of Veterans exposed to depleted uranium (DU) in the 1991 Gulf War were analyzed with no knowledge of their exposure history. Uranium levels in the Veterans’ semen samples ranged from undetectable (<0.8 pg/g) to 3350 pg/g. This wide concentration range for uranium in semen is consistent with known differences in current DU body burdens in these individuals, some of whom have retained embedded DU fragments.

  3. Silicon dioxide etching yield measurements with inductively coupled fluorocarbon plasmas

    International Nuclear Information System (INIS)

    Chae, Heeyeop; Vitale, Steven A.; Sawin, Herbert H.

    2003-01-01

    Oxide etching yield has been measured directly with inductively coupled fluorocarbon plasmas. The yields measurement technique of this work can provide useful information for feature profile evolution modeling, which is essential to understand various issues in oxide etching such as reactive ion etching (RIE) lag, inverse RIE lag, etch stop, microtrenching, bowing, etc. Etching and deposition yields per ion were measured using quartz crystal microbalance (QCM) as a function of ion bombardment energy, ion-to-neutral flux ratio, and ion-impinging angle. C 2 HF 5 , C 2 F 6 , C 2 H 4 F 2 , and C 4 F 8 were used for the oxide etching. Oxide etching mechanism with those gases is complex because etching and deposition are involved at the same time. In highly selective processes fluorocarbon deposition plays important role in determining etching characteristics. Two fluorocarbon deposition mechanisms are identified in this work: neutral deposition and ion-enhanced deposition. The low-energy ions are believed to enhance the deposition rates by creating active sites and fluorocarbon neutrals deposit on the active sites with higher sticking probability. A surface kinetic model is suggested to explain the ion-enhanced mechanism and shows good agreement with experimental data. Angular yield measurement shows that when fluorocarbon deposition is relatively severe, etching yield decreases significantly as the incident angle increases and deposit fluorocarbon at a high incident angle above 60 deg. C

  4. Plasma-based localized defect for switchable coupling applications

    International Nuclear Information System (INIS)

    Varault, Stefan; Gabard, Benjamin; Sokoloff, Jerome; Bolioli, Sylvain

    2011-01-01

    We report in this paper experimental measurements in order to validate the concept of switchable electromagnetic band gap filters based on plasma capillaries in the microwave regime. The plasma tube is embedded inside the structure to create a bistable (plasma on or off) punctual defect. We first investigate two kinds of discharge tubes: Ar-Hg and pure Ne, which we then use to experimentally achieve plasma-based reconfigurable applications, namely, a two-port coupler and a two-port demultiplexer.

  5. Diagonalization of coupled scalars and its application to the supersymmetric neutral Higgs sector

    International Nuclear Information System (INIS)

    Diaz, M.A.

    1997-05-01

    We introduce a momentum dependent mixing angle α(p 2 ) which allow us to diagonalize at any external momentum p the one-loop corrected inverse propagator matrix of two coupled scalar fields while keeping the full momentum dependence in the self energies. We compare this method with more traditional techniques applied to the diagonalization of coupled scalars at the one-loop level. This method is applied to the CP-even Higgs sector of the Minimal Supersymmetric Model, defining the momentum dependent mixing angle α(p 2 ), and calculating the two CP-even Higgs masses and the mixing angle at these two scales. We compare the results obtained in this way with alternative techniques. We make explicit the relation between α(p 2 ) and the running mixing angle. We find differences between the mixing angle calculated with our method compared with more traditional methods, and these differences are relevant for Higgs searches at LEP2. (author). 22 refs, 4 figs

  6. Affection and Couple Election among Teenagers from Popular Sectors of Cali

    Directory of Open Access Journals (Sweden)

    Fernando Urrea Giraldo

    2006-01-01

    Full Text Available This article explores the affection and the couple election production logics among teenagers from heterogeneous popular sectors of Cali city (Colombia, according to class, gender and race factors. Without seeking to look directly into the conjugality, anyway the text enters in the matter of couple’s election, under the restrictions of adolescent and post adolescent life cycle of our research program through the courtship, eventually with the option to cohabit and to have an offspring; in accordance with the information picked up to level of the interviews and the focal groups. In second place, when having the opportunity of a statistical data through household survey series between 1998 and the 2003 in Cali and the Valle del Cauca urban region, where Cali is placed, on Afrocolombian and non Afrocolombian population, we have been able to attempt a first approach to the racial homogamy phenomenon for the complete households (it means, with spouse’s presence, establishing the necessary links with the qualitative data to look from a macro social perspective the behavior of these logics among the teenagers. For that reason, the class, gender and race factors are seen through the racial homogamy category, in the sense of coming closer to the social constraints of the sexuality as a social practice, the affection and the intent of conjugal couple conformation in the Cali society.

  7. Equatorial nighttime vertical f-region plasma drifts during disturbed-time in the african sector

    Science.gov (United States)

    Oyekola, O. S.; Ojo, A.; Akinrimisi, J.

    The terrestrial ionosphere deals with the basic structure and variability of plasma within the upper atmosphere of the Earth Furthermore the ionosphere comprises less than one percent of the mass of the upper atmosphere yet it has a significant influence on advanced communication and navigation systems both have important economic consequences As society beings to rely on more complex technologies those systems become more susceptible to environmental effects However there is still considerable difficulty in the understanding of the equatorial ionospheric phenomena under different solar and geomagnetic conditions despite all extensive studies in the middle and high latitudes and in equatorial and low latitude American and Indian sectors By contrast there is a remarkably sparse database at equatorial African continent of the globe Consequently we infer F-region vertical plasma drifts at the magnetic equatorial station Ibadan 7 4 o N 3 9 o E 6 o S dip from the time variation of the hourly recorded ionosonde virtual height of F layer h F data obtained during 1957-58 International Geophysical Year IGY period corresponding to a year of high solar flux under geomagnetic disturbed night hours 1800-0600 LT The results show a strong geomagnetic control of ionospheric plasma drifts velocities variability in month-to-month and at three different seasonal conditions The largest random fluctuations are observed in June solstice months The evening and morning reversal times are highly variable The average magnitude of the downward

  8. Simulating the evolution of the Amundsen Sea Sector with a coupled ice-ocean model

    Science.gov (United States)

    Seroussi, H. L.; Nakayama, Y.; Menemenlis, D.; Larour, E. Y.; Morlighem, M.; Rignot, E. J.

    2017-12-01

    Ice shelves and floating glacier termini play an important role in the stability of ice sheets and interact strongly with the ocean. They account for much of the buttressing against the flow of inland glaciers that drain the Antarctic ice sheet. Changes in their geometry due to ice-front retreat, thinning or even collapse profoundly affect the flow of their tributary glaciers, which in turn affects the volume of grounded ice carried by these tributary glaciers into the ocean, and the extent of resulting sea level rise. Recent simulations of glaciers in Antarctica show that the largest climatic impact on ice dynamics is the rate of ice shelf melting, which rapidly affects glaciers' speed over several hundreds of kilometers upstream of the grounding line. These melting rates, however, as well as their spatial and temporal evolution remain largely unknown. In the absence of direct long-term observations, coupled ice-ocean models are the best available approach to address this question. In a previous study, we simulated the coupled ice-ocean system near Thwaites Glacier using a new two-way coupled system between the Massachusetts Institute of Technology general circulation model (MITgcm) and the Ice Sheet System Model (ISSM). Our results highlighted the impact of ocean conditions on glacier evolution and demonstrated the importance of simulating the coupled ice-ocean system to produce accurate melting rates under the ice shelf and at the grounding line. In this study, we focus on the entire Amundsen Sea sector, a region that experienced glacier acceleration, thinning and grounding line retreat over the past three decades. We investigate the feedbacks between changes in the ice and ocean, and the dynamic response of the glacier to changes in the ocean circulation. The simulations suggest that this region is likely to undergo substantial changes in the coming decades. This work was performed at the Jet Propulsion Laboratory, California Institute of Technology, under a

  9. Inductively coupled plasma nanoetching of atomic layer deposition alumina

    DEFF Research Database (Denmark)

    Han, Anpan; Chang, Bingdong; Todeschini, Matteo

    2018-01-01

    Al2O3 thin-film deposited by atomic layer deposition is an attractive plasma etch mask for Micro and Nano Electro-Mechanical Systems (MEMS and NEMS). 20-nm-thick Al2O3 mask enables through silicon wafer plasma etching. Al2O3 is also an excellent etch mask for other important MEMS materials...

  10. A Concept for Directly Coupled Pulsed Electromagnetic Acceleration of Plasmas

    Science.gov (United States)

    Thio, Y.C. Francis; Cassibry, Jason T.; Eskridge, Richard; Smith, James; Wu, S. T.; Rodgers, Stephen L. (Technical Monitor)

    2001-01-01

    Plasma jets with high momentum flux density are required for a variety of applications in propulsion research. Methods of producing these plasma jets are being investigated at NASA Marshall Space Flight Center. The experimental goal in the immediate future is to develop plasma accelerators which are capable of producing plasma jets with momentum flux density represented by velocities up to 200 km/s and ion density up to 10(exp 24) per cu m, with sufficient precision and reproducibility in their properties, and with sufficiently high efficiency. The jets must be sufficiently focused to allow them to be transported over several meters. A plasma accelerator concept is presented that might be able to meet these requirements. It is a self-switching, shaped coaxial pulsed plasma thruster, with focusing of the plasma flow by shaping muzzle current distribution as in plasma focus devices, and by mechanical tapering of the gun walls. Some 2-D MHD modeling in support of the conceptual design will be presented.

  11. Analysis of equatorial plasma bubble zonal drift velocities in the Pacific sector by imaging techniques

    Directory of Open Access Journals (Sweden)

    D. Yao

    2007-03-01

    Full Text Available Using 1024 nights of data from 2002–2005 taken by the Cornell Narrow Field Imager (CNFI, we examine equatorial plasma bubble (EPB zonal drift velocity characteristics. CNFI is located at the Maui Space Surveillance Site on the Haleakala Volcano (geographic: 20.71° N, 203.83° E; geomagnetic: 21.03° N, 271.84° E on the island of Maui, Hawaii. The imager is set up to view in a magnetic field-aligned geometry in order to maximize its resolution. We calculate the zonal drift velocities using two methods: a correlation routine and an EPB west-wall intensity gradient tracking routine. These two methods yield sizeable differences in the evenings, suggesting strong pre-local midnight EPB development. An analysis of the drift velocities is also performed based on the three influencing factors of season, geomagnetic activity, and solar activity. In general, our data match published trends and drift characteristics from past studies. However, we find that the drift magnitudes are much lower than results from other imagers at similar latitude sectors but at different longitude sectors, suggesting that zonal drift velocities have a longitudinal dependence.

  12. Ideal gas behavior of a strongly-coupled complex (dusty) plasma

    OpenAIRE

    Oxtoby, Neil P.; Griffith, Elias J.; Durniak, Céline; Ralph, Jason F.; Samsonov, Dmitry

    2012-01-01

    In a laboratory, a two-dimensional complex (dusty) plasma consists of a low-density ionized gas containing a confined suspension of Yukawa-coupled plastic microspheres. For an initial crystal-like form, we report ideal gas behavior in this strongly coupled system during shock-wave experiments. This evidence supports the use of the ideal gas law as the equation of state for soft crystals such as those formed by dusty plasmas.

  13. Self-diffusion for a weakly-coupled plasma in a magnetic field

    NARCIS (Netherlands)

    Cohen, J.S.; Suttorp, L.G.

    1984-01-01

    The longitudinal self-diffusion coefficient for a magnetized plasma with a small plasma parameter is calculated from kinetic theory in the weak-coupling approximation. Asymptotic expressions for this coefficient are derived in the limits of weak and of strong magnetic field. For intermediate

  14. Sample Preparation Problem Solving for Inductively Coupled Plasma-Mass Spectrometry with Liquid Introduction Systems I. Solubility, Chelation, and Memory Effects.

    Science.gov (United States)

    Pappas, R Steven

    2012-05-01

    This tutorial was adapted from the first half of a course presented at the 7th International Conference on Sector Field Inductively Coupled Plasma Mass Spectrometry in 2008 and the 2012 Winter Conference on Plasma Spectrochemistry on sample preparation for liquid introduction systems. Liquid introduction in general and flow injection specifically are the most widely used sample introduction methods for inductively coupled plasma-mass spectrometry. Nevertheless, problems persist in determination of analytes that are commonly investigated, as well as in specialty applications for those seldom considered by most analysts. Understanding the chemistry that is common to different groups of analytes permits the development of successful approaches to rinse-out and elimination of memory effects. This understanding also equips the analyst for development of successful elemental analytical approaches in the face of a broad spectrum of matrices and other analytical challenges, whether the sample is solid or liquid.

  15. Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry by direct injection nebulization for selenium speciation

    DEFF Research Database (Denmark)

    Bendahl, Lars; Gammelgaard, Bente; Jons, O.

    2001-01-01

    A demountable direct injection high efficiency nebulizer operating at low sample uptake rates was developed and used for coupling of capillary electrophoresis (CE) with inductively coupled plasma mass spectrometry (ICP-MS). When the nebulizer was used for continuous sample introduction, detection...

  16. Electromagnetic waves in an axion-active relativistic plasma non-minimally coupled to gravity

    International Nuclear Information System (INIS)

    Balakin, Alexander B.; Muharlyamov, Ruslan K.; Zayats, Alexei E.

    2013-01-01

    We consider cosmological applications of a new self-consistent system of equations, accounting for a non-minimal coupling of the gravitational, electromagnetic and pseudoscalar (axion) fields in a relativistic plasma. We focus on dispersion relations for electromagnetic perturbations in an initially isotropic ultrarelativistic plasma coupled to the gravitational and axion fields in the framework of isotropic homogeneous cosmological model of the de Sitter type. We classify the longitudinal and transversal electromagnetic modes in an axionically active plasma and distinguish between waves (damping, instable or running), and nonharmonic perturbations (damping or instable). We show that for the special choice of the guiding model parameters the transversal electromagnetic waves in the axionically active plasma, non-minimally coupled to gravity, can propagate with the phase velocity smaller than the speed of light in vacuum, thus displaying a possibility for a new type of resonant particle-wave interactions. (orig.)

  17. A comprehensive study of different gases in inductively coupled plasma torch operating at one atmosphere

    International Nuclear Information System (INIS)

    Punjabi, Sangeeta B.; Joshi, N. K.; Mangalvedekar, H. A.; Lande, B. K.; Das, A. K.; Kothari, D. C.

    2012-01-01

    A numerical study is done to understand the possible operating regimes of RF-ICP torch (3 MHz, 50 kW) using different gases for plasma formation at atmospheric pressure. A two dimensional numerical simulation of RF-ICP torch using argon, nitrogen, oxygen, and air as plasma gas has been investigated using computational fluid dynamic (CFD) software fluent (c) . The operating parameters varied here are central gas flow, sheath gas flow, RF-power dissipated in plasma, and plasma gas. The temperature contours, flow field, axial, and radial velocity profiles were investigated under different operating conditions. The plasma resistance, inductance of the torch, and the heat distribution for various plasma gases have also been investigated. The plasma impedance of ICP torch varies with different operating parameters and plays an important role for RF oscillator design and power coupling. These studies will be useful to decide the design criteria for ICP torches required for different material processing applications.

  18. ICRH antenna S-matrix measurements and plasma coupling characterisation at JET

    Science.gov (United States)

    Monakhov, I.; Jacquet, P.; Blackman, T.; Bobkov, V.; Dumortier, P.; Helou, W.; Lerche, E.; Kirov, K.; Milanesio, D.; Maggiora, R.; Noble, C.; Contributors, JET

    2018-04-01

    The paper is dedicated to the characterisation of multi-strap ICRH antenna coupling to plasma. Relevance of traditional concept of coupling resistance to antennas with mutually coupled straps is revised and the importance of antenna port excitation consistency for application of the concept is highlighted. A method of antenna S-matrix measurement in presence of plasma is discussed allowing deeper insight into the problem of antenna-plasma coupling. The method is based entirely on the RF plant hardware and control facilities available at JET and it involves application of variable phasing between the antenna straps during the RF plant operations at  >100 kW. Unlike traditional techniques relying on low-power (~10 mW) network analysers, the applied antenna voltage amplitudes are relevant to practical conditions of ICRH operations; crucially, they are high enough to minimise possible effects of antenna loading non-linearity due to the RF sheath effects and other phenomena which could affect low-power measurements. The method has been successfully applied at JET to conventional 4-port ICRH antennas energised at frequencies of 33 MHz, 42 MHz and 51 MHz during L-mode plasma discharges while different gas injection modules (GIMs) were used to maintain comparable plasma densities during the pulses. The S-matrix assessment and its subsequent processing yielding ‘global’ antenna coupling resistances in conditions of equalised port maximum voltages allowed consistent description of antenna coupling to plasma at different strap phasing, operational frequencies and applied GIMs. Comprehensive experimental characterisation of mutually coupled antenna straps in presence of plasma also provided a unique opportunity for in-depth verification of TOPICA computer simulations.

  19. Effects of coupling efficiency on atomic spectrometry with a microwave-induced plasma

    International Nuclear Information System (INIS)

    Burns, B.A.

    1987-01-01

    The atmospheric-pressure, microwave-induced argon plasma from a TM 010 mode cavity is made nearly 100% efficient by matching the impedance of the generator to the impedance of the load. The impedance match is achieved by increasing the size of the coupling probe and by varying cavity permittivity and microwave probe position to lower the reflected power to nearly zero watts. The efficient microwave plasma is capable of operating with as little as 5 watts of power, producing plasma plumes of 16 cm in length when operated at 100 watts, reflecting almost no measurable power, and generating virtually no cavity heat. With plasma power known for all operating conditions, experiments were performed to help create a model for the efficient operation of the cavity at all input powers. This model was used to correlate the plasma electron density with plasma power for a further fundamental understanding of the microwave-induced plasma. The model for the efficient microwave plasma is related to the changes in cavity E-field intensity with changes in plasma electron production. The model describes the flow of power from the generator to the plasma and allows correlation of observed phenomena, i.e., plasma electron density and analyte emission intensity, with plasma power

  20. Morphology of equatorial plasma bubbles during low and high solar activity years over Indian sector

    Science.gov (United States)

    Kumar, Sanjay

    2017-05-01

    In the present study, slant total electron content (STEC) data computed from ground based GPS measurements over Hyderabad (Geog. Lat. 17.41° N, geog. long. 78.55° E, mag. lat. 08.81° N) and two close stations at Bangalore (Geog. Lat. 13.02°/13.03° N, geog. long. 77.57°/77.51° E, mag. lat. 04.53°/04.55° N) in Indian region during 2007-2012, have been used to study the occurrences and characteristics of equatorial plasma bubbles (EPBs). The analysis found maximum EPB occurrences during the equinoctial months and minimum during the December solstice throughout 2007-2012 except during the solar minimum years in 2007-2009. During 2007-2009, the maximum EPB occurrences were observed in June solstice which could not be predicted by the model proposed by Tsunoda (J. Geophys. Res., 90:447-456, 1985). The equinox maximum in EPB occurrences for high solar activity years could be caused by the vertical F-layer drift due to pre-reversal electric field (PRE), and expected to be maximum when day-night terminator aligns with the magnetic meridian i.e. during the equinox months whereas maximum occurrences during the solstice months of solar minimum could be caused by the seed perturbation in plasma density induced by gravity waves from tropospheric origins. Generally EPB occurrences are found to be more prominent during nighttime hours (2000-2400 hours) than the daytime hours. Peak in EPB occurrences is in early night for high solar activity years whereas same is late night for low solar activity. The day and nighttime EPB occurrences have been analyzed and found to vary in accordance with solar activity with an annual correlation coefficient (R) of ˜0.99 with F_{10.7} cm solar Flux. Additionally, solar activity influence on EPB occurrences is seasonal dependent with a maximum influence during the equinox season (R=0.88) and a minimum during winter season (R =0.73). The solar activity influences on EPB occurrences are found in agreement with the previous works reported in

  1. Measuring the EOS of a Dense, Strongly Coupled Plasma; Description of the Technique

    International Nuclear Information System (INIS)

    Benage, John F. Jr.; Kyraka, George; Workman, Jonathan; Tierney, Thomas

    1997-08-01

    This paper describes a new experimental design which we believe can produce reasonably accurate data for the equation of state (EOS) of a dense plasma. This design takes advantage of the standard shock technique used for determining the high pressure EOS of solids. It also utilizes recently developed experimental techniques for producing dense, strongly coupled plasmas as well as new diagnostic techniques for measuring the properties of these plasmas. The results should be able to distinguish among theoretical models for plasmas at just under solid density and temperatures of 10's of eV

  2. Antenna coupling study for ICWC plasma characterization in TEXTOR

    Indian Academy of Sciences (India)

    2013-01-06

    Jan 6, 2013 ... and TORE SUPRA [15,17]. At such low density (ne ∼ 5 × 1016 m. −3), fast magne- tosonic waves (FW) are non-propagating for the antenna k -spectrum corresponding to dipole phasing. More homogeneous plasma formation in the vessel was obtained in the. MC scenario in gas (He+H2)-mixture, ...

  3. Measurements of time average series resonance effect in capacitively coupled radio frequency discharge plasma

    International Nuclear Information System (INIS)

    Bora, B.; Bhuyan, H.; Favre, M.; Wyndham, E.; Chuaqui, H.; Kakati, M.

    2011-01-01

    Self-excited plasma series resonance is observed in low pressure capacitvely coupled radio frequency discharges as high-frequency oscillations superimposed on the normal radio frequency current. This high-frequency contribution to the radio frequency current is generated by a series resonance between the capacitive sheath and the inductive and resistive bulk plasma. In this report, we present an experimental method to measure the plasma series resonance in a capacitively coupled radio frequency argon plasma by modifying the homogeneous discharge model. The homogeneous discharge model is modified by introducing a correction factor to the plasma resistance. Plasma parameters are also calculated by considering the plasma series resonances effect. Experimental measurements show that the self-excitation of the plasma series resonance, which arises in capacitive discharge due to the nonlinear interaction of plasma bulk and sheath, significantly enhances both the Ohmic and stochastic heating. The experimentally measured total dissipation, which is the sum of the Ohmic and stochastic heating, is found to increase significantly with decreasing pressure.

  4. Ratio of bulk to shear viscosity in a quasigluon plasma: from weak to strong coupling

    CERN Document Server

    Bluhm, M; Redlich, K

    2012-01-01

    The ratio of bulk to shear viscosity is expected to exhibit a different behaviour in weakly and in strongly coupled systems. This can be expressed by the dependence of the ratio on the squared sound velocity. In the high temperature QCD plasma at small running coupling, the viscosity ratio is uniquely determined by a quadratic dependence on the conformality measure, whereas in certain strongly coupled and nearly conformal theories this dependence is linear. Employing an effective kinetic theory of quasiparticle excitations with medium-modified dispersion relation, we analyze the ratio of bulk to shear viscosity of the gluon plasma. We show that in this approach the viscosity ratio comprises both dependencies found by means of weak coupling perturbative and strong coupling holographic techniques.

  5. Coupled two-dimensional edge plasma and neutral gas modeling of tokamak scrape-off-layers

    International Nuclear Information System (INIS)

    Maingi, R.

    1992-08-01

    The objective of this study is to devise a detailed description of the tokamak scrape-off-layer (SOL), which includes the best available models of both the plasma and neutral species and the strong coupling between the two in many SOL regimes. A good estimate of both particle flux and heat flux profiles at the limiter/divertor target plates is desired. Peak heat flux is one of the limiting factors in determining the survival probability of plasma-facing-components at high power levels. Plate particle flux affects the neutral flux to the pump, which determines the particle exhaust rate. A technique which couples a two-dimensional (2-D) plasma and a 2-D neutral transport code has been developed (coupled code technique), but this procedure requires large amounts of computer time. Relevant physics has been added to an existing two-neutral-species model which takes the SOL plasma/neutral coupling into account in a simple manner (molecular physics model), and this model is compared with the coupled code technique mentioned above. The molecular physics model is benchmarked against experimental data from a divertor tokamak (DIII-D), and a similar model (single-species model) is benchmarked against data from a pump-limiter tokamak (Tore Supra). The models are then used to examine two key issues: free-streaming-limits (ion energy conduction and momentum flux) and the effects of the non-orthogonal geometry of magnetic flux surfaces and target plates on edge plasma parameter profiles

  6. Modelling of plasma-antenna coupling and non-linear radio frequency wave-plasma-wall interactions in the magnetized plasma device under ion cyclotron range of frequencies

    International Nuclear Information System (INIS)

    Lu, LingFeng

    2016-01-01

    Ion Cyclotron Resonant Heating (ICRH) by waves in 30-80 MHz range is currently used in magnetic fusion plasmas. Excited by phased arrays of current straps at the plasma periphery, these waves exist under two polarizations. The Fast Wave tunnels through the tenuous plasma edge and propagates to its center where it is absorbed. The parasitically emitted Slow Wave only exists close to the launchers. How much power can be coupled to the center with 1 A current on the straps? How do the emitted radiofrequency (RF) near and far fields interact parasitically with the edge plasma via RF sheath rectification at plasma-wall interfaces? To address these two issues simultaneously, in realistic geometry over the size of ICRH antennas, this thesis upgraded and tested the Self-consistent Sheaths and Waves for ICH (SSWICH) code. SSWICH couples self-consistently RF wave propagation and Direct Current (DC) plasma biasing via non-linear RF and DC sheath boundary conditions (SBCs) at plasma/wall interfaces. Its upgrade is full wave and was implemented in two dimensions (toroidal/radial). New SBCs coupling the two polarizations were derived and implemented along shaped walls tilted with respect to the confinement magnetic field. Using this new tool in the absence of SBCs, we studied the impact of a density decaying continuously inside the antenna box and across the Lower Hybrid (LH) resonance. Up to the memory limits of our workstation, the RF fields below the LH resonance changed with the grid size. However the coupled power spectrum hardly evolved and was only weakly affected by the density inside the box. In presence of SBCs, SSWICH-FW simulations have identified the role of the fast wave on RF sheath excitation and reproduced some key experimental observations. SSWICH-FW was finally adapted to conduct the first electromagnetic and RF-sheath 2D simulations of the cylindrical magnetized plasma device ALINE. (author) [fr

  7. The effect of hydrogen on B4C coatings fabrication in inductively coupled plasma torch

    Directory of Open Access Journals (Sweden)

    Q. J. Guo

    2018-02-01

    Full Text Available Boron carbide (B4C coatings are prepared by an RF inductively coupled plasma (ICP torch with different amounts of hydrogen introduced into the sheath gas. The effects of the added hydrogen on the characteristics of the plasma are diagnosed by optical emission spectroscopy and high speed photography. The effects on the melting of B4C particles in the plasma are studied by scanning electron microscopy (SEM. The microstructure of the B4C coatings was determined with SEM imaging and x-ray diffraction analysis. The results show that adding hydrogen to the sheath gas leads to plasma contraction, which results in higher gas temperature of plasma. It also enhances B4C particles spheroidizing and improves the compactness of B4C coatings. Plasma processing does not change the main phase of boron carbide. The obtained results on B4C coatings on Cu substrates allows for improving the B4C coatings fabrication process.

  8. Use of plasma-source multicollector magnetic-sector mass spectrometry for uranium and plutonium analysis in environmental samples

    International Nuclear Information System (INIS)

    Price Russ, G.; Williams, Ross

    2001-01-01

    Full text: The ability to detect and isotopically characterize uranium and plutonium in environmental samples is of primary importance in the search for nuclear proliferation. The utility of isotope ratio measurements for environmental monitoring is limited by sample preparation costs, measurement precision, and sensitivity. This is particularly true for wide-area monitoring where the number of samples required varies inversely with obtainable precision and sensitivity. Historically isotopic measurements have been made by thermal ionization mass spectrometry (TIMS). While requiring extensive sample preparation, no other technique matched its precision and sensitivity for such measurements. Inductively-coupled-plasma, magnetic-sector, multicollector, mass spectrometry offers the prospect of extending the state-of-the-art to higher precision while increasing sensitivity and reducing costs through more rapid analysis and reduced sample preparation. At LLNL this technique is being implemented in the form of an IsoProbe (Micromass, UK). This paper will present data for both standards and IAEA supplied samples demonstrating the power and limitations of the technique. The precision and sensitivity of the IsoProbe results will be compared to TIMS performance for comparable samples. For 48 determinations of natural uranium, using the double spike to correct for bias, a relative standard deviation of 0.04% (1σ) for 238 U/ 235 U has been obtained in a preliminary study. This is a substantial improvement over the TIMS result of 0.1% reported at the previous conference. Further improvements can be expected as we gain a better understanding of the background peaks occurring in the IsoProbe spectra. (author)

  9. Determination of selenoprotein P in human plasma by solid phase extraction and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L.; Sidenius, U.; Gammelgaard, Bente

    2000-01-01

    A method based on solid phase extraction was developed for the determination of selenoprotein P as selenium in human plasma. Separation of selenoprotein P from other selenium-containing proteins was accomplished by immobilized metal-ion affinity chromatography. The selenium content was subsequently...... measured by inductively coupled plasma mass spectrometry (ICP-MS) monitoring the Se-82 isotope. Linear response was observed in the concentration range 0.3-70.8 mu g/l selenium as selenoprotein P with a correlation coefficient of 0.9994. The precision expressed as relative standard deviation was better...

  10. Strong Helioseismic Constraints on Weakly-Coupled Plasmas

    Science.gov (United States)

    Nayfonov, Alan

    The extraordinary accuracy of helioseismic data allows detailed theoretical studies of solar plasmas. The necessity to produce solar models matching the experimental results in accuracy imposes strong constrains on the equations of state of solar plasmas. Several discrepancies between the experimental data and models have been successfully identified as the signatures of various non-ideal phenomena. Of a particular interest are questions of the position of the energy levels and the continuum edge and of the effect of the excited states in the solar plasma. Calculations of energy level and continuum shifts, based on the Green function formalism, appeared recently in the literature. These results have been used to examine effects of the shifts on the thermodynamic quantities. A comparison with helioseismic data has shown that the calculations based on lower-level approximations, such as the static screening in the effective two-particle wave equation, agree very well with the experimental data. However, the case of full dynamic screening produces thermodynamic quantities inconsistent with observations. The study of the effect of different internal partition functions on a complete set of thermodynamic quantities has revealed the signature of the excited states in the MHD (Mihalas, Hummer, Dappen) equation of state. The presence of exited states causes a characteristic 'wiggle' in the thermodynamic quantities due to the density-dependent occupation probabilities. This effect is absent if the ACTEX (ACTivity EXpansion) equation of state is used. The wiggle has been found to be most prominent in the quantities sensitive to density. The size of this excited states effect is well within the observational power of helioseismology, and very recent inversion analyses of helioseismic data seem to indicate the presence of the wiggle in the sun. This has a potential importance for the helioseismic determination of the helium abundance of the sun.

  11. Collisional Thermalization in Strongly Coupled Ultracold Neutral Plasmas

    Science.gov (United States)

    2017-01-25

    NUMBER 5b. GRANT NUMBER FA9550-12-1-0267 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Thomas C Killian 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT...density plasmas such as inertial confinement fusion experiments and in nature in the interiors of gas giant planets and the crusts of neutron stars...report, e.g. AFOSR-82-1234. 5c. PROGRAM ELEMENT NUMBER. Enter all program element numbers as they appear in the report, e.g. 61101A. 5d. PROJECT

  12. A new air-cooled argon/helium-compatible inductively coupled plasma torch.

    Science.gov (United States)

    Miyahara, Hidekazu; Iwai, Takahiro; Kaburaki, Yuki; Kozuma, Tomokazu; Shigeta, Kaori; Okino, Akitoshi

    2014-01-01

    A new inductively coupled plasma (ICP) torch with an air-cooling system has been designed and developed for both argon and helium plasma. The same torch and impedance-matching network could be used to generate stable Ar- and He-ICP. The torch consists of three concentric quartz tubes. The carrier gas, plasma gas, and cooling gas flow through the intervals between each tube. In an experiment, it was found that Ar-ICP could form a stable plasma under the following conditions: RF power of 1 kW, plasma gas flow rate of 11 L min(-1), and cooling gas flow rate of 20 L min(-1). For He-ICP, an input RF power of 2 kW, which is two-times higher than that of a conventional He-ICP, could be constantly applied to the plasma with plasma gas and cooling gas flow rates of 15 and 20 L min(-1), respectively. Using this torch, it is possible to realize lower plasma gas consumption for Ar- and He-ICP and a high-power drive for He-ICP. It has been found that the air-cooling gas stabilizes the shape of the plasma due to the pressure difference between the cooling gas and the plasma gas.

  13. Recent observations of traveling ionospheric disturbances and plasma bubbles using Optical Mesosphere Thermosphere Imagers in Asian and African sectors

    Science.gov (United States)

    Shiokawa, K.; Otsuka, Y.; Tsuchiya, S.; Moral, A. C.; Okoh, D.

    2017-12-01

    We review recent observational results of medium-scale traveling ionospheric disturbances (MSTIDs) and equatorial plasma bubbles obtained by using airglow imagers and Fabry-Perot interferometers of the Optical Mesosphere Thermosphere Imagers (OMTIs) at Asian and African sectors. The OMTIs contains 20 airglow imagers and 5 Fabry-Perot interferometers (FPIs) at Canada, USA (Alaska), Russia, Finland, Norway, Iceland, Japan, Thailand, Indonesia, Australia, and Nigeria (http://stdb2.isee.nagoya-u.ac.jp/omti/). The 3-dimentional Fast Fourier Transformation of airglow images makes it possible to analyze 16-year airglow images obtained at Shigaraki (34.8N) and Rikubetsu (43.5N), Japan, to obtain phase velocity spectra of gravity waves and MSTIDs. The MSTIDs spectra show clear southwestward preference of propagation and minor northeastward propagation over Japan. We also found clear negative correlation between MSTID power and solar F10.7 flux, indicating that MSTIDs becomes more active during solar quiet time. This fact suggest the control of ionospheric Perkins and E-F coupling instabilities by solar activities. Three TIDs in airglow images over Indonesia, including midnight brightness waves (MBWs), were compared with CHAMP-satellite overpass to investigate neutral density variations in the thermosphere associated with the TIDs. We found clear correspondence in variations between the airglow intensities and neutral densities, suggesting that the observed TIDs over the equatorial region is caused by gravity waves. We also compare average thermospheric temperatures measured by the four FPIs for 3-4 years with the MSIS90E and GAIA models. The comparison shows that GAIA generally shows better fitting than the MSIS90E, but at the equatorial stations, GAIA tends to fail to reproduce the FPI temperature, probably due to ambiguity of location of the midnight temperature maximum. We also made statistics of plasma bubble occurrence using airglow imager and GNSS receiver at Abuja (9

  14. Dynamic properties of one-component strongly coupled plasmas: The sum-rule approach

    International Nuclear Information System (INIS)

    Arkhipov, Yu. V.; Askaruly, A.; Davletov, A. E.; Ballester, D.; Tkachenko, I. M.; Zwicknagel, G.

    2010-01-01

    The dynamic characteristics of strongly coupled one-component plasmas are studied within the moment approach. Our results on the dynamic structure factor and the dynamic local-field correction satisfy the sum rules and other exact relations automatically. A quantitative agreement is obtained with numerous simulation data on the plasma dynamic properties, including the dispersion and decay of collective modes. Our approach allows us to correct and complement the results previously found with other treatments.

  15. HAIFA: A modular, fiber-optic coupled, spectroscopic diagnostic for plasmas

    International Nuclear Information System (INIS)

    Ramsey, A.T.; Turner, S.L.

    1987-01-01

    HAIFA is a modular, multichannel, fiber optically coupled spectroscopy diagnostic for tokamak plasmas. It operates in the visible, measuring H/sub α/ radiation, the visible continuum from thermal bremsstrahlung, and selected impurity lines. HAIFA is characterized by high modularity and flexibility, good radiation resistance, high noise immunity, and low cost. Details of design, construction, and calibration are given. The analysis of visible bremsstrahlung radiation measurements to deduce the effective ionic charge in a plasma is discussed

  16. Effects of Reentry Plasma Sheath on Mutual-Coupling Property of Array Antenna

    Directory of Open Access Journals (Sweden)

    B. W. Bai

    2015-01-01

    Full Text Available A plasma sheath enveloping a reentry vehicle would cause the failure of on-board antennas, which is an important effect that contributes to the “blackout” problem. The method of replacing the on-board single antenna with the array antennas and using beamforming technology has been proposed to mitigate “blackout” problem by many other researchers. Because the plasma sheath is a reflective medium, plasma will alter the mutual coupling between array elements and degrade the beamforming performance of array antenna. In this paper, the effects of the plasma sheath on the mutual coupling properties between adjacent array elements are studied utilizing the algorithm of finite integration technique. Results show that mutual coupling coefficients of array elements are deteriorating more seriously with the decrease of collision frequency. Moreover, when electron density and collision frequency are both large, plasma sheath improves the mutual coupling property of array elements; this conclusion suggests that replacing the on-board single antenna with the array antennas and using beamforming technology can be adopted to mitigate the blackout problem in this condition.

  17. Influence of coupling on atmosphere, sea ice and ocean regional models in the Ross Sea sector, Antarctica

    Energy Technology Data Exchange (ETDEWEB)

    Jourdain, Nicolas C. [LGGE, UMR 5183, CNRS-UJF, Grenoble (France); LEGI, UMR 5519, CNRS-UJF-INPG, Grenoble (France); Mathiot, Pierre; Barnier, Bernard [LEGI, UMR 5519, CNRS-UJF-INPG, Grenoble (France); Gallee, Hubert [LGGE, UMR 5183, CNRS-UJF, Grenoble (France)

    2011-04-15

    Air-sea ice-ocean interactions in the Ross Sea sector form dense waters that feed the global thermohaline circulation. In this paper, we develop the new limited-area ocean-sea ice-atmosphere coupled model TANGO to simulate the Ross Sea sector. TANGO is built up by coupling the atmospheric limited-area model MAR to a regional configuration of the ocean-sea ice model NEMO. A method is then developed to identify the mechanisms by which local coupling affects the simulations. TANGO is shown to simulate realistic sea ice properties and atmospheric surface temperatures. These skills are mostly related to the skills of the stand alone atmospheric and oceanic models used to build TANGO. Nonetheless, air temperatures over ocean and winter sea ice thickness are found to be slightly improved in coupled simulations as compared to standard stand alone ones. Local atmosphere ocean feedbacks over the open ocean are found to significantly influence ocean temperature and salinity. In a stand alone ocean configuration, the dry and cold air produces an ocean cooling through sensible and latent heat loss. In a coupled configuration, the atmosphere is in turn moistened and warmed by the ocean; sensible and latent heat loss is therefore reduced as compared to the stand alone simulations. The atmosphere is found to be less sensitive to local feedbacks than the ocean. Effects of local feedbacks are increased in the coastal area because of the presence of sea ice. It is suggested that slow heat conduction within sea ice could amplify the feedbacks. These local feedbacks result in less sea ice production in polynyas in coupled mode, with a subsequent reduction in deep water formation. (orig.)

  18. Interstellar turbulence model : A self-consistent coupling of plasma and neutral fluids

    International Nuclear Information System (INIS)

    Shaikh, Dastgeer; Zank, Gary P.; Pogorelov, Nikolai

    2006-01-01

    We present results of a preliminary investigation of interstellar turbulence based on a self-consistent two-dimensional fluid simulation model. Our model describes a partially ionized magnetofluid interstellar medium (ISM) that couples a neutral hydrogen fluid to a plasma through charge exchange interactions and assumes that the ISM turbulent correlation scales are much bigger than the shock characteristic length-scales, but smaller than the charge exchange mean free path length-scales. The shocks have no influence on the ISM turbulent fluctuations. We find that nonlinear interactions in coupled plasma-neutral ISM turbulence are influenced substantially by charge exchange processes

  19. Stable explicit coupling of the Yee scheme with a linear current model in fluctuating magnetized plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Filipe da, E-mail: tanatos@ipfn.ist.utl.pt [Instituto de Plasmas e Fusão Nuclear, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa (Portugal); Pinto, Martin Campos, E-mail: campos@ann.jussieu.fr [CNRS, UMR 7598, Laboratoire Jacques-Louis Lions, F-75005, Paris (France); Sorbonne Universités, UPMC Univ Paris 06, UMR 7598, Laboratoire Jacques-Louis Lions, F-75005, Paris (France); Després, Bruno, E-mail: despres@ann.jussieu.fr [Sorbonne Universités, UPMC Univ Paris 06, UMR 7598, Laboratoire Jacques-Louis Lions, F-75005, Paris (France); CNRS, UMR 7598, Laboratoire Jacques-Louis Lions, F-75005, Paris (France); Heuraux, Stéphane, E-mail: stephane.heuraux@univ-lorraine.fr [Institut Jean Lamour, UMR 7198, CNRS – University Lorraine, Vandoeuvre (France)

    2015-08-15

    This work analyzes the stability of the Yee scheme for non-stationary Maxwell's equations coupled with a linear current model with density fluctuations. We show that the usual procedure may yield unstable scheme for physical situations that correspond to strongly magnetized plasmas in X-mode (TE) polarization. We propose to use first order clustered discretization of the vectorial product that gives back a stable coupling. We validate the schemes on some test cases representative of direct numerical simulations of X-mode in a magnetic fusion plasma including turbulence.

  20. Solid Carbon Produced in an Inductively Coupled Plasma Torch with a Titan Like Atmosphere

    Directory of Open Access Journals (Sweden)

    D. Vacher

    2013-01-01

    Full Text Available Solid carbon is deposited on the surfaces of an inductively coupled plasma torch operating with a Titan like atmosphere plasma gas. The frame of the initial research is the study of the radiative properties of plasma encountered around a spacecraft during its hypersonic entry in upper layers of planetary atmosphere. Deposition of carbon is observed not only on the quartz tube outside the inductor but also on the ceramic protection of the torch injector. Carbon exhibits two types of morphology more or less dense and it is analyzed by various analytic devices as MEB, SEM, TEM, EDS and Raman spectroscopy. The gathered carbon powder shows the presence of nanostructured particles.

  1. Energy Conservation Tests of a Coupled Kinetic-kinetic Plasma-neutral Transport Code

    Energy Technology Data Exchange (ETDEWEB)

    Stotler, D. P.; Chang, C. S.; Ku, S. H.; Lang, J.; Park, G.

    2012-08-29

    A Monte Carlo neutral transport routine, based on DEGAS2, has been coupled to the guiding center ion-electron-neutral neoclassical PIC code XGC0 to provide a realistic treatment of neutral atoms and molecules in the tokamak edge plasma. The DEGAS2 routine allows detailed atomic physics and plasma-material interaction processes to be incorporated into these simulations. The spatial pro le of the neutral particle source used in the DEGAS2 routine is determined from the uxes of XGC0 ions to the material surfaces. The kinetic-kinetic plasma-neutral transport capability is demonstrated with example pedestal fueling simulations.

  2. Inductively Coupled Plasma-Induced Etch Damage of GaN p-n Junctions

    International Nuclear Information System (INIS)

    SHUL, RANDY J.; ZHANG, LEI; BACA, ALBERT G.; WILLISON, CHRISTI LEE; HAN, JUNG; PEARTON, S.J.; REN, F.

    1999-01-01

    Plasma-induced etch damage can degrade the electrical and optical performance of III-V nitride electronic and photonic devices. We have investigated the etch-induced damage of an Inductively Coupled Plasma (ICP) etch system on the electrical performance of mesa-isolated GaN pn-junction diodes. GaN p-i-n mesa diodes were formed by Cl 2 /BCl 3 /Ar ICP etching under different plasma conditions. The reverse leakage current in the mesa diodes showed a strong relationship to chamber pressure, ion energy, and plasma flux. Plasma induced damage was minimized at moderate flux conditions (≤ 500 W), pressures ≥2 mTorr, and at ion energies below approximately -275 V

  3. Inductively Coupled Plasma-Induced Etch Damage of GaN p-n Junctions

    Energy Technology Data Exchange (ETDEWEB)

    SHUL,RANDY J.; ZHANG,LEI; BACA,ALBERT G.; WILLISON,CHRISTI LEE; HAN,JUNG; PEARTON,S.J.; REN,F.

    1999-11-03

    Plasma-induced etch damage can degrade the electrical and optical performance of III-V nitride electronic and photonic devices. We have investigated the etch-induced damage of an Inductively Coupled Plasma (ICP) etch system on the electrical performance of mesa-isolated GaN pn-junction diodes. GaN p-i-n mesa diodes were formed by Cl{sub 2}/BCl{sub 3}/Ar ICP etching under different plasma conditions. The reverse leakage current in the mesa diodes showed a strong relationship to chamber pressure, ion energy, and plasma flux. Plasma induced damage was minimized at moderate flux conditions ({le} 500 W), pressures {ge}2 mTorr, and at ion energies below approximately -275 V.

  4. Inductively coupled hydrogen plasma processing of AZO thin films for heterojunction solar cell applications

    International Nuclear Information System (INIS)

    Zhou, H.P.; Xu, S.; Zhao, Z.; Xiang, Y.

    2014-01-01

    Highlights: • A high-density plasma reactor of inductively coupled plasma source is used in this work. • The conductivity and transmittance can be enhanced simultaneously in the hydrogen process. • The formation of additional donors and passivation due to the hydrogen plasma processing. • The photovoltaic improvement due to the improved AZO layer and hetero-interface quality in the solar cells. - Abstract: Al-doped ZnO (AZO) thin films deposited by means of RF magnetron sputtering were processed in a low frequency inductively coupled plasma of H 2 , aiming at heterojunction (HJ) solar cell applications. A variety of characterization results show that the hydrogen plasma processing exerts a significant influence on the microstructures, electrical and optical properties of the AZO films. The incorporation of hydrogen under the optimum treatment simultaneously promoted the transmittance and conductivity due to the hydrogen associated passivation effect on the native defects and the formation of shallow donors in the films, respectively. A p-type c-Si based HJ solar cell with a front AZO contact was also treated in as-generated non-equilibrium hydrogen plasma and the photovoltaic performance of the solar cell was prominently improved. The underlying mechanism was discussed in terms of the beneficial impacts of high-density hydrogen plasma on the properties of AZO itself and the hetero-interfaces involved in the HJ structure (interface defect and energy band configuration)

  5. Influence of driving frequency on oxygen atom density in O2 radio frequency capacitively coupled plasma

    International Nuclear Information System (INIS)

    Kitajima, Takeshi; Noro, Kouichi; Nakano, Toshiki; Makabe, Toshiaki

    2004-01-01

    The influence of the driving frequency on the absolute oxygen atom density in an O 2 radio frequency (RF) capacitively coupled plasma (CCP) was investigated using vacuum ultraviolet absorption spectroscopy with pulse modulation of the main plasma. A low-power operation of a compact inductively coupled plasma light source was enabled to avoid the significant measurement errors caused by self-absorption in the light source. The pulse modulation of the main plasma enabled accurate absorption measurement for high plasma density conditions by eliminating background signals due to light emission from the main plasma. As for the effects of the driving frequency, the effect of VHF (100 MHz) drive on oxygen atom production was small because of the modest increase in plasma density of electronegative O 2 in contrast to the significant increase in electron density previously observed for electropositive Ar. The recombination coefficient of oxygen atoms on the electrode surface was obtained from a decay rate in the afterglow by comparison with a diffusion model, and it showed agreement with previously reported values for several electrode materials

  6. Characteristics of an elongated plasma column produced by magnetically coupled hollow cathode plasma source

    Science.gov (United States)

    Bhuva, M. P.; Karkari, S. K.; Kumar, Sunil

    2018-03-01

    An elongated plasma column in the presence of an axial magnetic field has been formed using a cylindrical hollow cathode (HC) and a constricted anode (CA). The plasma characteristics of the central line have been found to vary with the magnetic field strength and the axial distance from the source. It is believed that the primary electrons constituting the discharge current are steered by the axial magnetic field to undertake ionizing collisions along the plasma column. The current carrying electrons from the HC reach the anode by cross-field diffusion towards the central line. The above observation has been substantiated using a phenomenological model which links the observed characteristics of the source with the plasma column. The experimental results are found to be in qualitative agreement with the model.

  7. Induced magnetic-field effects in inductively coupled plasmas

    International Nuclear Information System (INIS)

    Cohen, R.H.; Rognlien, T.D.

    1995-01-01

    In inductive plasma sources, the rapid spatial decay of the electric field arising from the skin effect produces a large radio frequency (RF) magnetic field via Faraday's law. We previously determined that this magnetic field leads to a reduction of the electron density in the skin region, as well as a reduction in the collisionless heating rate. The electron deficit leads to the formation of an electrostatic potential which pulls electrons in to restore quasineutrality. Here we calculate the electron density including both the induced and electrostatic fields. If the wave frequency is not too low, the ions respond only to the averaged fields, and hence the electrostatic field is oscillatory, predominantly at the second harmonic of the applied field. We calculate the potential required to establish a constant electron density, and compare with numerical orbit-code calculations. For times short compared to ion transit times, the quasineutral density is just the initial ion density. For timescales long enough that the ions can relax, the density profile can be found from the solution of fluid equations with an effective (ponderomotive-like) potential added. Although the time-varying electrostatic potential is an extra source of heating, the net effect of the induced magnetic and electrostatic fields through trapping, early turning, and direct heating is a significant reduction in collisionless heating for parameters of interest

  8. In situ calibration of inductively coupled plasma-atomic emission and mass spectroscopy

    Science.gov (United States)

    Braymen, Steven D.

    1996-06-11

    A method and apparatus for in situ addition calibration of an inductively coupled plasma atomic emission spectrometer or mass spectrometer using a precision gas metering valve to introduce a volatile calibration gas of an element of interest directly into an aerosol particle stream. The present situ calibration technique is suitable for various remote, on-site sampling systems such as laser ablation or nebulization.

  9. Fast-Projectile Stopping Power of Quantal Multicomponent Strongly Coupled Plasmas

    International Nuclear Information System (INIS)

    Ballester, D.; Tkachenko, I. M.

    2008-01-01

    The Bethe-Larkin formula for the fast-projectile stopping power is extended to multicomponent plasmas. The results are to contribute to the correct interpretation of the experimental data, which could permit us to test existing and future models of thermodynamic, static, and dynamic characteristics of strongly coupled Coulomb systems

  10. Efficient coupling of 527 nm laser beam power to a long scale-length plasma

    International Nuclear Information System (INIS)

    Moody, J.D.; Divol, L.; Glenzer, S.H.; MacKinnon, A.J.; Froula, D.H.; Gregori, G.; Kruer, W.L.; Meezan, N.B.; Suter, L.J.; Williams, E.A.; Bahr, R.; Seka, W.

    2006-01-01

    We experimentally demonstrate that application of laser smoothing schemes including smoothing by spectral dispersion (SSD) and polarization smoothing (PS) increases the intensity range for efficient coupling of frequency doubled (527 nm) laser light to a long scale-length plasma with n e /n cr equals 0.14 and T e equals 2 keV. (authors)

  11. Polymerization by plasma of trichloroethylene by means of resistive and inductive coupling

    International Nuclear Information System (INIS)

    Vasquez, M.; Cruz, G.; Olayo, M.G.; Timoshina, T.; Morales, J.; Olayo, R.

    2004-01-01

    It was carried out the polymerization for plasma of the trichloroethylene by means of two types of coupling, resistive and inductive with the objective of studying the structure, morphology and the electric properties of the polymers obtained under these conditions. The structure and morphology of the polymers were studied by means of EDS and FT-IR spectroscopies. (Author)

  12. Atlas of atomic spectral lines of plutonium emitted by an inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Edelson, M.C.; DeKalb, E.L.; Winge, R.K.; Fassel, V.A.

    1986-09-01

    Optical emission spectra from high-purity Pu-242 were generated with a glovebox-enclosed inductively coupled plasma (ICP) source. Spectra covering the 2280 to 7008 Angstrom wavelength range are presented along with general commentary on ICP-Pu spectroscopy.

  13. Determination of Arsenic in Sinus Wash and Tap Water by Inductively Coupled Plasma-Mass Spectrometry

    Science.gov (United States)

    Donnell, Anna M.; Nahan, Keaton; Holloway, Dawone; Vonderheide, Anne P.

    2016-01-01

    Arsenic is a toxic element to which humans are primarily exposed through food and water; it occurs as a result of human activities and naturally from the earth's crust. An experiment was developed for a senior level analytical laboratory utilizing an Inductively Coupled Plasma-Mass Spectrometer (ICP-MS) for the analysis of arsenic in household…

  14. Enhanced thermal photon and dilepton production in strongly coupled = 4 SYM plasma in strong magnetic field

    Science.gov (United States)

    Mamo, Kiminad A.

    2013-08-01

    We calculate the DC conductivity tensor of strongly coupled = 4 super-Yang-Mills (SYM) plasma in a presence of a strong external magnetic field B ≫ T 2 by using its gravity dual and employing both the RG flow approach and membrane paradigm which give the same results. We find that, since the magnetic field B induces anisotropy in the plasma, different components of the DC conductivity tensor have different magnitudes depending on whether its components are in the direction of the magnetic field B. In particular, we find that a component of the DC conductivity tensor in the direction of the magnetic field B increases linearly with B while the other components (which are not in the direction of the magnetic field B) are independent of it. These results are consistent with the lattice computations of the DC conductivity tensor of the QCD plasma in an external magnetic field B. Using the DC conductivity tensor, we calculate the soft or low-frequency thermal photon and dilepton production rates of the strongly coupled = 4 SYM plasma in the presence of the strong external magnetic field B ≫ T 2. We find that the strong magnetic field B enhances both the thermal photon and dilepton production rates of the strongly coupled = 4 SYM plasma in a qualitative agreement with the experimentally observed enhancements at the heavy-ion collision experiments.

  15. Two-dimensional simulation of a miniaturized inductively coupled plasma reactor

    International Nuclear Information System (INIS)

    Nam, Sang Ki; Economou, Demetre J.

    2004-01-01

    A two-dimensional self-consistent simulation of a miniaturized inductively coupled plasma (mICP) reactor was developed. The coupled equations for plasma power deposition, electron temperature, and charged and neutral species densities, were solved to obtain the spatial distribution of an argon discharge. The effect of control parameters, such as power and pressure, on the evolution of plasma density and electron temperature was investigated. Strong ion density gradients were observed which can make spatially resolved Langmuir probe measurements particularly challenging. Simulation results were in reasonable agreement with available experimental data. The neutral gas temperature was predicted to be close to the wall temperature, due to the small length scale of the mICP, allowing for efficient heat transfer

  16. Inductively coupled plasma and ion sources: History and state-of-the-art

    International Nuclear Information System (INIS)

    Hopwood, J.

    1994-01-01

    Over 100 years ago Hittorf first generated an electrodeless ''ring'' discharge by electromagnetic induction and began a 40 year controversy as to the true physical origin of such a discharge. Even Tesla advocated that these plasmas were merely the result of large electrostatic potential differences rather than electric fields induced by high frequency currents. Through clever experiments using crude spark gaps and leyden jars, the inductive nature of the discharge was confirmed in the late 1920's by MacKinnon, thus supporting the theories and experiments of Sir J.J. Thomson, perhaps the most staunch advocate of the induction mechanism. Today the authors routinely exploit the intense plasmas which are generated by induction. In this talk, the characteristics of inductively coupled plasma (ICP) and ion sources will be reviewed and future applications of intense plasma sources will be discussed. The inductively coupled plasma is Joule heated at moderate gas pressures, but the electromagnetic field penetration of these dense plasmas is limited by the plasma skin depth, typically a few millimeters to a few centimeters. The induction plasma is thus edge heated, a fact that constrains uniformity over large areas if helical induction coils are used. Flat, spiral coils may be used to improve uniformity by driving the plasma using a planar geometry. Issues of dimensional and frequency scaling will be discussed as they apply to large diameter sources. Ion beams extracted from ICPs are used for many applications including space propulsion, high power neutral beams, and materials processing. Broad ion beam (∼10 cm) current densities in excess of 100 mA-cm 2 at 100 keV are obtained in pulsed mode operation. Recently, however, more consumer-oriented applications of less intense ICPs are emerging

  17. Low-frequency, high-density, inductively coupled plasma sources: Operation and applications

    Science.gov (United States)

    Xu, S.; Ostrikov, K. N.; Li, Y.; Tsakadze, E. L.; Jones, I. R.

    2001-05-01

    Operation regimes, plasma parameters, and applications of the low-frequency (˜500 kHz) inductively coupled plasma (ICP) sources with a planar external coil are investigated. It is shown that highly uniform, high-density (ne˜9×1012 cm-3) plasmas can be produced in low-pressure argon discharges with moderate rf powers. The low-frequency ICP sources operate in either electrostatic (E) or electromagnetic (H) regimes in a wide pressure range without any Faraday shield or an external multipolar magnetic confinement, and exhibit high power transfer efficiency, and low circuit loss. In the H mode, the ICP features high level of uniformity over large processing areas and volumes, low electron temperatures, and plasma potentials. The low-density, highly uniform over the cross-section, plasmas with high electron temperatures and plasma and sheath potentials are characteristic to the electrostatic regime. Both operation regimes offer great potential for various plasma processing applications. As examples, the efficiency of the low-frequency ICP for steel nitriding and plasma-enhanced chemical vapor deposition of hydrogenated diamond-like carbon (DLC) films, is demonstrated. It appears possible to achieve very high nitriding rates and dramatically increase micro-hardness and wear resistance of the AISI 304 stainless steel. It is also shown that the deposition rates and mechanical properties of the DLC films can be efficiently controlled by selecting the discharge operating regime.

  18. Investigations into the origins of polyatomic ions in inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McIntyre, Sally M. [Iowa State Univ., Ames, IA (United States)

    2010-01-01

    An inductively coupled plasma-mass spectrometer (ICP-MS) is an elemental analytical instrument capable of determining nearly all elements in the periodic table at limits of detection in the parts per quadrillion and with a linear analytical range over 8-10 orders of magnitude. Three concentric quartz tubes make up the plasma torch. Argon gas is spiraled through the outer tube and generates the plasma powered by a looped load coil operating at 27.1 or 40.6 MHz. The argon flow of the middle channel is used to keep the plasma above the innermost tube through which solid or aqueous sample is carried in a third argon stream. A sample is progressively desolvated, atomized and ionized. The torch is operated at atmospheric pressure. To reach the reduced pressures of mass spectrometers, ions are extracted through a series of two, approximately one millimeter wide, circular apertures set in water cooled metal cones. The space between the cones is evacuated to approximately one torr. The space behind the second cone is pumped down to, or near to, the pressure needed for the mass spectrometer (MS). The first cone, called the sampler, is placed directly in the plasma plume and its position is adjusted to the point where atomic ions are most abundant. The hot plasma gas expands through the sampler orifice and in this expansion is placed the second cone, called the skimmer. After the skimmer traditional MS designs are employed, i.e. quadrupoles, magnetic sectors, time-of-flight. ICP-MS is the leading trace element analysis technique. One of its weaknesses are polyatomic ions. This dissertation has added to the fundamental understanding of some of these polyatomic ions, their origins and behavior. Although mainly continuing the work of others, certain novel approaches have been introduced here. Chapter 2 includes the first reported efforts to include high temperature corrections to the partition functions of the polyatomic ions in ICP-MS. This and other objections to preceeding

  19. Continuum Lowering and Fermi-Surface Rising in Strongly Coupled and Degenerate Plasmas

    Science.gov (United States)

    Hu, S. X.

    2017-08-01

    Continuum lowering is a well known and important physics concept that describes the ionization potential depression (IPD) in plasmas caused by thermal- or pressure-induced ionization of outer-shell electrons. The existing IPD models are often used to characterize plasma conditions and to gauge opacity calculations. Recent precision measurements have revealed deficits in our understanding of continuum lowering in dense hot plasmas. However, these investigations have so far been limited to IPD in strongly coupled but nondegenerate plasmas. Here, we report a first-principles study of the K -edge shifting in both strongly coupled and fully degenerate carbon plasmas, with quantum molecular dynamics calculations based on the all-electron density-functional theory. The resulting K -edge shifting versus plasma density, as a probe to the continuum lowering and the Fermi-surface rising, is found to be significantly different from predictions of existing IPD models. In contrast, a simple model of "single-atom-in-box," developed in this work, accurately predicts K -edge locations as ab initio calculations provide.

  20. Effective coupling of ultraintense laser pulse to funnel-mouthed plasma waveguides

    International Nuclear Information System (INIS)

    Wu Jianzhou; Cooley, James H.; Antonsen, Thomas M. Jr.; Milchberg, Howard M.

    2005-01-01

    The injection of laser pulses into hydrodynamically preformed plasma channels can be hindered by the conditions at the entrance of the channel. In particular, neutral gas and narrowing of the channel prevent efficient coupling of laser pulse entering into the channel. To solve this problem, a funnel-shaped plasma lens can be grafted onto the channel using an auxiliary formation pulse. Simulations of channel formation show that such a funnel can be made in the density ramp of a gas jet. Simulations of laser pulse propagation show that such a funnel efficiently couples pulse energy into the channel. For a backfill target with a funnel, the coupling efficiency is lower and required funnel parameters are more restrictive than for the gas jet case

  1. Fluid simulation of the phase-shift effect in hydrogen capacitively coupled plasmas: II. Radial uniformity of the plasma characteristics

    International Nuclear Information System (INIS)

    Zhang Yuru; Xu Xiang; Wang Younian; Bogaerts, Annemie

    2012-01-01

    A two-dimensional fluid model, including the full set of Maxwell equations, has been developed and applied to investigate the effect of a phase shift between two power sources on the radial uniformity of several plasma characteristics in a hydrogen capacitively coupled plasma. This study was carried out at various frequencies in the range 13.56-200 MHz. When the frequency is low, at 13.56 MHz, the plasma density is characterized by an off-axis peak when both power sources are in-phase (φ = 0), and the best radial uniformity is obtained at φ = π. This trend can be explained because the radial nonuniformity caused by the electrostatic edge effect can be effectively suppressed by the phase-shift effect at a phase difference equal to π. When the frequency rises to 60 MHz, the plasma density profiles shift smoothly from edge-peaked over uniform to centre-peaked as the phase difference increases, due to the pronounced standing-wave effect, and the best radial uniformity is reached at φ = 0.3π. At a frequency of 100 MHz, a similar behaviour is observed, except that the maximum of the plasma density moves again towards the radial edge at the reverse-phase case (φ = π), because of the dominant skin effect. When the frequency is 200 MHz, the bulk plasma density increases significantly with increasing phase-shift values, and a better uniformity is obtained at φ = 0.4π. This is because the density in the centre increases faster than at the radial edge as the phase difference rises, due to the increasing power deposition P z in the centre and the decreasing power density P r at the radial edge. As the phase difference increases to π, the maximum near the radial edge becomes obvious again. This is because the skin effect has a predominant influence on the plasma density under this condition, resulting in a high density at the radial edge. Moreover, the axial ion flux increases monotonically with phase difference, and exhibits similar profiles to the plasma density

  2. Higgs quartic coupling and neutrino sector evolution in 2UED models

    KAUST Repository

    Abdalgabar, A.

    2014-05-20

    Two compact universal extra-dimensional models are an interesting class of models for different theoretical and phenomenological issues, such as the justification of having three standard model fermion families, suppression of proton decay rate, dark matter parity from relics of the six-dimensional Lorentz symmetry, origin of masses and mixings in the standard model. However, these theories are merely effective ones, with typically a reduced range of validity in their energy scale. We explore two limiting cases of the three standard model generations all propagating in the bulk or all localised to a brane, from the point of view of renormalisation group equation evolutions for the Higgs sector and for the neutrino sector of these models. The recent experimental results of the Higgs boson from the LHC allow, in some scenarios, stronger constraints on the cutoff scale to be placed, from the requirement of the stability of the Higgs potential. 2014 The Author(s).

  3. Experimental and simulation investigation of electrical and plasma parameters in a low pressure inductively coupled argon plasma

    Science.gov (United States)

    Jian, YANG; Angjian, WU; Xiaodong, LI; Yang, LIU; Fengsen, ZHU; Zhiliang, CHEN; Jianhua, YAN; Ruijuan, CHEN; Wangjun, SHEN

    2017-11-01

    The electrical and plasma parameters of a low pressure inductively coupled argon plasma are investigated over a wide range of parameters (RF power, flow rate and pressure) by diverse characterizations. The external antenna voltage and current increase with the augment of RF power, whereas decline with the enhancement of gas pressure and flow rate conversely. Compared with gas flow rate and pressure, the power transfer efficiency is significantly improved by RF power, and achieved its maximum value of 0.85 after RF power injected excess 125 W. Optical emission spectroscopy (OES) provides the local mean values of electron excited temperature and electron density in inductively coupled plasma (ICP) post regime, which vary in a range of 0.81 eV to 1.15 eV and 3.7× {10}16 {{{m}}}-3 to 8.7× {10}17 {{{m}}}-3, respectively. Numerical results of the average magnitudes of electron temperature and electron density in two-dimensional distribution exhibit similar variation trend with the experimental results under different operating condition by using COMSOL Multiphysics. By comprehensively understanding the characteristics in a low pressure ICP, optimized operating conditions could be anticipated aiming at different academic and industrial applications.

  4. Theory and modelling of second harmonic ICRF coupling and heating in inhomogeneous plasmas

    International Nuclear Information System (INIS)

    Shokair, I.R.; Conn, R.W.; Mau, T.K.

    1988-01-01

    The combined theory of ion cyclotron wave coupling, mode conversion and absorption is developed for bounded inhomogeneous plasmas in slab geometry. The plasma response to the RF waves is described by the linearized Vlasov equation, with an equilibrium distribution function and a poloidal magnetic field profile which are self-consistent solutions of the equilibrium Vlasov and Maxwell's equations. A general form of the wave equation, valid to arbitrary order in Larmor radius and including first order gradient terms, is derived. Expressions are also derived for the plasma intrinsic impedance. The wave equation, keeping second order terms in Larmor radius, is solved numerically for a plasma bounded by two conducting walls using the INTOR tokamak design parameters. It was found that the effect of the one-dimensional poloidal field is small. Also, a rough estimate of the error due to truncation to second order in Larmor radius was made and was found to be very small except in the high temperature regions. The effects of plasma boundedness and reflections from the mode conversion region on the coupling of waves from the RF source as a function of the plasma parameters and antenna spectra are studied. It is found that, at certain values of the plasma and antenna parameters, eigenmodes are formed, resulting in an increase in the loading impedance. It is verified that the impedance is not symmetric with respect to the spectrum in the poloidal direction, with highly peaked resonances. As the plasma temperature is increased, the resonances broaden and eventually disappear at very high temperatures. This is attributed to increased single pass absorption and decreasing reflection from the mode conversion region. (author). 20 refs, 15 figs, 2 tabs

  5. Precise determination of dissolved silica in seawater by ion-exclusion chromatography isotope dilution inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Nonose, Naoko; Cheong, Chikako; Ishizawa, Yukari; Miura, Tsutomu; Hioki, Akiharu

    2014-08-20

    Ion exclusion chromatograph (IEC) isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) (IEC-ID-ICP-MS) was developed for measurement of dissolved silica in seawater, which was applied to production of certified reference materials (CRMs) of three concentration levels of nutrients (high, medium and low levels). IEC-ICP-MS has been employed to separate dissolved silica from seawater matrix. In the present study, in order to solve substantial problems due to spectral interference in ICP-MS and to improve the accuracy of IEC-ICP-MS beyond standard addition or conventional calibration methods, ID method was coupled with ICP-sector field mass spectrometry (operated under medium resolution,i.e., m/Δm=4000). In addition, effects of various operating parameters in ICP-MS on a silicon background level were also investigated to obtain lower background equivalent concentration (BEC). As a result, 3 ng g(-1) of the BEC and 0.5 % of relative standard uncertainties were achieved in the analyses of dissolved silica in seawater samples at concentration levels from 4.0 mg kg (-1) to 0.8 mg kg(-1) as silicon. The developed method was successfully validated by analyses of an artificial seawater containing a known amount of silicate and the seawater certified reference material MOOS-2 produced by the National Research Council Canada. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Anisotropic shear viscosity of a strongly coupled non-Abelian plasma from magnetic branes

    Science.gov (United States)

    Critelli, R.; Finazzo, S. I.; Zaniboni, M.; Noronha, J.

    2014-09-01

    Recent estimates for the electromagnetic fields produced in the early stages of noncentral ultrarelativistic heavy ion collisions indicate the presence of magnetic fields B ˜O(0.1-15mπ2), where mπ is the pion mass. It is then of special interest to study the effects of strong (Abelian) magnetic fields on the transport coefficients of strongly coupled non-Abelian plasmas, such as the quark-gluon plasma formed in heavy ion collisions. In this paper we study the anisotropy in the shear viscosity induced by an external magnetic field in a strongly coupled N =4 super Yang-Mills (SYM) plasma. Due to the spatial anisotropy created by the magnetic field, the most general viscosity tensor of a magnetized plasma has five shear viscosity coefficients and two bulk viscosities. We use the holographic correspondence to evaluate two of the shear viscosities, η⊥≡ηxyxy (perpendicular to the magnetic field) and η∥≡ηxzxz=ηyzyz (parallel to the field). When B ≠0 the shear viscosity perpendicular to the field saturates the viscosity bound η⊥/s=1/(4π), while in the direction parallel to the field the bound is violated since η∥/s<1/(4π). However, the violation of the bound in the case of strongly coupled SYM is minimal even for the largest value of B that can be reached in heavy ion collisions.

  7. Capacitively Coupled RF Plasmas for the Synthesis of Silicon Nanocrystals: Scaling and Mechanisms

    Science.gov (United States)

    Markosyan, Aram H.; Le Picard, Romain; Porter, David H.; Girshick, Steven L.; Kushner, Mark J.

    2015-09-01

    Silicon nanocrystals (SNCs) are of interest for light emitting electronics, photovoltaics, and biotechnology. SNCs are produced in low pressure capacitively coupled plasmas (CCPs) sustained in SiH4 containing mixtures. To optimize these applications, it is necessary to control the size distribution of the SNCs. Particles 3-5 nm diameter are typically tailored by flow rates and power, however the fundamental processes responsible for this size control are not well understood. We developed a 2-d computer model for RF powered CCPs to predict the synthesis of SNCs. An aerosol sectional model was incorporated into the Hybrid Plasma Equipment Model. The reactor is a quartz tube a few mm in diameter through which 100 sccm Ar and 15 sccm He/SiH4 = 95/5 at 2 Torr are flowed. The SNC residence time is 1-2 ms in the dense plasma region near the electrodes. We found that the distribution of plasma potential is important in determining the growth and size distribution of the SNCs. The SNCs having long residence times in the plasma, thereby enabling growth, are usually negatively charged. To ultimately allow these SNCs to flow out of the plasma, the distribution of the plasma potential must enable the particles to be entrained in the neutral gas flow without a significant potential barrier. We also found that agglomeration of particles of <1 nm is important in the rate of growth of SNCs. Work supported by DOE (DE-SC0001939) and NSF (CHE-124752).

  8. Time-resolved spatial distribution measurements of pulse-modulated argon plasmas in an inductively coupled plasma reactor

    Science.gov (United States)

    Park, Ji-Hwan; Kim, Dong-Hwan; Kim, Yu-Sin; Chung, Chin-Wook

    2017-05-01

    The time variation of the plasma parameters along with their spatial distributions were measured in pulse-modulated (PM) inductively coupled argon plasma via the phase delay harmonic analysis method (PDHAM). During the initial active-glow, the distributions of both the ion flux and the electron temperature in the plasma bulk have M-shaped profiles due to the antenna geometry. Then, while the plasma is approaching a steady state, the spatial distribution evolves into a profile with a convex shape. The effects of the antenna geometry and the time evolution on the distribution profile are lesser under low gas pressure, and diminish at the wafer level. The diffusion of the charged particles and the nonlocal electron kinetics account for these characteristics. It is observed that the initial distribution of the electron temperature is affected by the electron density distribution of the previous after-glow at the wafer level. The distribution profiles at different pulse frequencies were also measured. At higher pulse frequencies, the distribution profile is more frequently smoothed by diffusion during the after-glow, leading to higher uniformity.

  9. Simulation of Main Plasma Parameters of a Cylindrical Asymmetric Capacitively Coupled Plasma Micro-Thruster using Computational Fluid Dynamics

    Directory of Open Access Journals (Sweden)

    Amelia eGreig

    2015-01-01

    Full Text Available Computational fluid dynamics (CFD simulations of a radio-frequency (13.56 MHz electro-thermal capacitively coupled plasma (CCP micro-thruster have been performed using the commercial CFD-ACE+ package. Standard operating conditions of a 10 W, 1.5 Torr argon discharge were used to compare with previously obtained experimental results for validation. Results show that the driving force behind plasma production within the thruster is ion-induced secondary electrons ejected from the surface of the discharge tube, accelerated through the sheath to electron temperatures up to 33.5 eV. The secondary electron coefficient was varied to determine the effect on the discharge, with results showing that full breakdown of the discharge did not occur for coefficients coefficients less than or equal to 0.01.

  10. Large loop-coupling enhancement of a heavy pseudoscalar from a light dark sector

    Energy Technology Data Exchange (ETDEWEB)

    Di Chiara, Stefano, E-mail: stefano.dichiara@kbfi.ee [National Institute of Chemical Physics and Biophysics, Rävala pst. 10, 10143 Tallinn (Estonia); Hektor, Andi; Kannike, Kristjan [National Institute of Chemical Physics and Biophysics, Rävala pst. 10, 10143 Tallinn (Estonia); Marzola, Luca; Raidal, Martti [National Institute of Chemical Physics and Biophysics, Rävala pst. 10, 10143 Tallinn (Estonia); Institute of Physics, University of Tartu, Ravila 14c, 50411 Tartu (Estonia)

    2017-04-15

    The small background and the sensitivity to charged particles via a leading order loop coupling make the diphoton channel a privileged experimental test for new physics models. We propose a simple archetypal scenario to generate a sharp di-photon resonance as a result of threshold enhancements in the effective coupling between a heavy pseudoscalar particle and new vector-like leptons. We therefore study three different scenarios consistent with the current experimental limits and deviating from the Standard Model at the 2 σ level. The model also introduces a natural dark matter candidate able to match the observed dark matter abundance and comfortably respect the current direct detection constraints.

  11. Final Report on Hierarchical Coupled Modeling and Prediction of Regional Climate Change in the Atlantic Sector

    Energy Technology Data Exchange (ETDEWEB)

    Saravanan, Ramalingam [Texas A& M University

    2011-10-30

    During the course of this project, we have accomplished the following: a) Carried out studies of climate changes in the past using a hierarchy of intermediate coupled models (Chang et al., 2008; Wan et al 2009; Wen et al., 2010a,b) b) Completed the development of a Coupled Regional Climate Model (CRCM; Patricola et al., 2011a,b) c) Carried out studies testing hypotheses testing the origin of systematic errors in the CRCM (Patricola et al., 2011a,b) d) Carried out studies of the impact of air-sea interaction on hurricanes, in the context of barrier layer interactions (Balaguru et al)

  12. Linking the Power and Transport Sectors—Part 2: Modelling a Sector Coupling Scenario for Germany

    Directory of Open Access Journals (Sweden)

    Martin Robinius

    2017-07-01

    Full Text Available “Linking the power and transport sectors—Part 1” describes the general principle of “sector coupling” (SC, develops a working definition intended of the concept to be of utility to the international scientific community, contains a literature review that provides an overview of relevant scientific papers on this topic and conducts a rudimentary analysis of the linking of the power and transport sectors on a worldwide, EU and German level. The aim of this follow-on paper is to outline an approach to the modelling of SC. Therefore, a study of Germany as a case study was conducted. This study assumes a high share of renewable energy sources (RES contributing to the grid and significant proportion of fuel cell vehicles (FCVs in the year 2050, along with a dedicated hydrogen pipeline grid to meet hydrogen demand. To construct a model of this nature, the model environment “METIS” (models for energy transformation and integration systems we developed will be described in more detail in this paper. Within this framework, a detailed model of the power and transport sector in Germany will be presented in this paper and the rationale behind its assumptions described. Furthermore, an intensive result analysis for the power surplus, utilization of electrolysis, hydrogen pipeline and economic considerations has been conducted to show the potential outcomes of modelling SC. It is hoped that this will serve as a basis for researchers to apply this framework in future to models and analysis with an international focus.

  13. Transport Theory for Plasmas that are Strongly Magnetized and Strongly Coupled

    Science.gov (United States)

    Baalrud, Scott; Daligault, Jerome

    2016-10-01

    Plasmas with components that are magnetized, strongly coupled, or both arise in a variety of frontier plasma physics experiments including magnetized dusty plasmas, nonneutral plasmas, magnetized ICF concepts, as well as from self-generated fields in ICF. Here, a species is considered strongly magnetized if the gyroradius is smaller than the spatial scale over which Coulomb interactions occur. A theory for transport properties is described that treats a wide range of both coupling and magnetization strengths. The approach is based on an extension of the recent effective potential transport theory to include a strong magnetic field. The underlying kinetic theory is based on an extension of the Boltzmann equation to include a strong magnetic field in the dynamics of binary scattering events. Corresponding magnetohydrodynamic equations are derived by solving the kinetic equation using a Chapman-Enskog like spectral method. Results are compared with classical molecular dynamics simulations of self-diffusion of the one component plasmas, and with simulations of parallel to perpendicular temperature equilibration of an initially anisotropic distribution. This material is based upon work supported by AFOSR Award FA9550-16-1-0221 and DOE OFES Award DE-SC0016159.

  14. Experimental benchmark of kinetic simulations of capacitively coupled plasmas in molecular gases

    Science.gov (United States)

    Donkó, Z.; Derzsi, A.; Korolov, I.; Hartmann, P.; Brandt, S.; Schulze, J.; Berger, B.; Koepke, M.; Bruneau, B.; Johnson, E.; Lafleur, T.; Booth, J.-P.; Gibson, A. R.; O'Connell, D.; Gans, T.

    2018-01-01

    We discuss the origin of uncertainties in the results of numerical simulations of low-temperature plasma sources, focusing on capacitively coupled plasmas. These sources can be operated in various gases/gas mixtures, over a wide domain of excitation frequency, voltage, and gas pressure. At low pressures, the non-equilibrium character of the charged particle transport prevails and particle-based simulations become the primary tools for their numerical description. The particle-in-cell method, complemented with Monte Carlo type description of collision processes, is a well-established approach for this purpose. Codes based on this technique have been developed by several authors/groups, and have been benchmarked with each other in some cases. Such benchmarking demonstrates the correctness of the codes, but the underlying physical model remains unvalidated. This is a key point, as this model should ideally account for all important plasma chemical reactions as well as for the plasma-surface interaction via including specific surface reaction coefficients (electron yields, sticking coefficients, etc). In order to test the models rigorously, comparison with experimental ‘benchmark data’ is necessary. Examples will be given regarding the studies of electron power absorption modes in O2, and CF4-Ar discharges, as well as on the effect of modifications of the parameters of certain elementary processes on the computed discharge characteristics in O2 capacitively coupled plasmas.

  15. External control of the synchronization dynamics of two inductively coupled glow discharge plasma sources

    Science.gov (United States)

    Chaubey, Neeraj; Mukherjee, S.; Sen, A.

    2017-10-01

    An experimental investigation of the influence of an external periodic forcing on the synchronization dynamics of two inductively coupled plasma sources is reported. The driven response of the coupled system is found to have a rich structure in the parameter space of the frequency and the amplitude of the external driver. In particular, there is a strong impact on the nature of the phase-flip transitions between anti-phase and in-phase synchronized states of the system and the frequency bifurcation structure of the collective states. The external driver provides a convenient tool for accessing various collective states of the system and controlling the collective dynamics of the two coupled systems through a proper choice of its frequency and amplitude. Our experimental results are qualitatively supported by numerical simulation results from a theoretical model of two environmentally coupled van der Pol equations, one of which is also driven externally.

  16. The determination of transition probabilities with an inductively-coupled plasma discharge

    International Nuclear Information System (INIS)

    Nieuwoudt, G.

    1984-03-01

    The 27 MHz inductively-coupled plasma discharge (ICP) is used for the determination of relative transition probabilities of the 451, 459 and 470 nm argon spectral lines. The temperature of the argon plasma is determined with hydrogen as thermometric specie, because of the accurate transition probabilities ( approximately 1% uncertainty) there of. The relative transition probabilities of the specific argon spectral lines were determined by substitution of the measured spectral radiances thereof, together with the hydrogen temperature, in the two-line equation of temperature measurement

  17. Line photon transport in a non-homogeneous plasma using radiative coupling coefficients

    International Nuclear Information System (INIS)

    Florido, R.; Gil, J.M.; Rodriguez, R.; Rubiano, J.G.; Martel, P.; Florido, R.; Gil, J.M.; Rodriguez, R.; Rubiano, J.G.; Martel, P.; Minguez, E.

    2006-01-01

    We present a steady-state collisional-radiative model for the calculation of level populations in non-homogeneous plasmas with planar geometry. The line photon transport is taken into account following an angle- and frequency-averaged escape probability model. Several models where the same approach has been used can be found in the literature, but the main difference between our model and those ones is that the details of geometry are exactly treated in the definition of coupling coefficients and a local profile is taken into account in each plasma cell. (authors)

  18. The influence of gas pressure on E↔H mode transition in argon inductively coupled plasmas

    OpenAIRE

    Xiao Zhang; Zhong-kai Zhang; Jin-xiang Cao; Yu Liu; Peng-cheng Yu

    2018-01-01

    Considering the gas pressure and radio frequency power change, the mode transition of E↔H were investigated in inductively coupled plasmas. It can be found that the transition power has almost the same trend decreasing with gas pressure, whether it is in H mode or E mode. However, the transition density increases slowly with gas pressure from E to H mode. The transition points of E to H mode can be understood by the propagation of electromagnetic wave in the plasma, while the H to E should be...

  19. Linearly coupled oscillations in fully degenerate pair and warm pair-ion astrophysical plasmas

    Science.gov (United States)

    Khan, S. A.; Ilyas, M.; Wazir, Z.; Ehsan, Zahida

    2014-08-01

    In this paper we study the coexisting low frequency oscillations in strongly degenerate, magnetized, (electron-positron) pair and warm pair-ion plasma. The dispersion relations are obtained for both the cases in macroscopic quantum hydrodynamics approximation. In pair-ion case, the dispersion equation shows coupling of electrostatic and (shear) electromagnetic modes under certain circumstances with important role of ion temperature. Domain of existence of such waves and their relevance to dense degenerate astrophysical plasmas is pointed out. Results are analyzed numerically for typical systems with variation of ion concentration and ion temperature.

  20. Viscosity calculated in simulations of strongly coupled dusty plasmas with gas friction

    International Nuclear Information System (INIS)

    Feng Yan; Goree, J.; Liu Bin

    2011-01-01

    A two-dimensional strongly coupled dusty plasma is modeled using Langevin and frictionless molecular dynamical simulations. The static viscosity η and the wave-number-dependent viscosity η(k) are calculated from the microscopic shear in the random motion of particles. A recently developed method of calculating the wave-number-dependent viscosity η(k) is validated by comparing the results of η(k) from the two simulations. It is also verified that the Green-Kubo relation can still yield an accurate measure of the static viscosity η in the presence of a modest level of friction as in dusty plasma experiments.

  1. Experimental Measurement of Self-Diffusion in a Strongly Coupled Plasma

    Science.gov (United States)

    2016-08-04

    and ni for all the analysis regions are shown with vertical error bars representing the standard deviation . ωp and Γi are calculated from Ti and ni for... standard - deviation uncertainties of the mean values, which we use in the main article to calculate the uncer- tainties in hΔvxðtÞiþ=hΔvxð0Þiþ. The fits to...Areas: Atomic and Molecular Physics, Plasma Physics, Statistical Physics I. INTRODUCTION In strongly coupled plasmas [1], the Coulomb interaction energy

  2. Computation and analysis of the electron transport properties for nitrogen and air inductively-coupled plasmas

    Science.gov (United States)

    Yu, Minghao; Kihara, Hisashi; Abe, Ken-ichi; Takahashi, Yusuke

    2015-06-01

    A relatively simple method for calculating accurately the third-order electron transport properties of nitrogen and air thermal plasmas is presented. The electron transport properties, such as the electrical conductivity and the electron thermal conductivity, were computed with the best and latest available collision cross-section data in the temperature and pressure ranges of T = 300 - 15000 K and p = 0.01 - 1.0 atm, respectively. The results obtained under the atmospheric pressure condition showed good agreements with the experimental and the high-accuracy theoretical results. The presently-introduced method has good application potential in numerical simulations of nitrogen and air inductively-coupled plasmas.

  3. Electron beam instabilities in unmagnetized plasmas via the Stieltjes transform (linear theory and nonlinear mode coupling)

    International Nuclear Information System (INIS)

    Krishan, S.

    2007-01-01

    The Stieltjes transform has been used in place of a more common Laplace transform to determine the time evolution of the self-consistent field (SCF) of an unmagnetized semi-infinite plasma, where the plasma electrons together with a primary and a low-density secondary electron beam move perpendicular to the boundary surface. The secondary beam is produced when the primary beam strikes the grid. Such a plasma system has been investigated by Griskey and Stanzel [M. C. Grisky and R. L. Stenzel, Phys. Rev. Lett. 82, 556 (1999)]. The physical phenomenon, observed in their experiment, has been named by them as ''secondary beam instability.'' The character of the instability observed in the experiment is not the same as predicted by the conventional treatments--the field amplitude does not grow with time. In the frequency spectrum, the theory predicts peak values in the amplitude of SCF at the plasma frequency of plasma and secondary beam electrons, decreasing above and below it. The Stieltjes transform for functions, growing exponentially in the long time limit, does not exist, while the Laplace transform technique gives only exponentially growing solutions. Therefore, it should be interesting to know the kind of solutions that an otherwise physically unstable plasma will yield. In the high-frequency limit, the plasma has been found to respond to any arbitrary frequency of the initial field differentiated only by the strength of the resulting SCF. The condition required for exponential growth in the conventional treatments, and the condition for maximum amplitude (with respect to frequency) in the present treatment, have been found to be the same. Nonlinear mode coupling between the modes excited by the plasma electrons and the low-density secondary beam gives rise to two frequency-dependent peaks in the field amplitude, symmetrically located about the much stronger peak due to the plasma electrons, as predicted by the experiment

  4. The coupling of capillary electrophoresis-inductively coupled plasma mass spectrometer as a speciation instrument for actinides at trace level

    International Nuclear Information System (INIS)

    Delorme, A.

    2004-01-01

    An interface between the separation technique (capillary electrophoresis) and the analytical technique (Inductively Coupled Plasma - Mass Spectrometer) was developed. In that sense, bibliographic and parametric studies allowed to define necessary conditions for the good working of both techniques. The results obtained led to the realisation of an interface capillary electrophoresis / ICP-MS (CE / ICP-MS). This one was experimentally validated on classical separations (alkalis / earth-alkalis and lanthanides) and the detection limit of the analytical system was determined equal to 4 x 10 -11 mol.L -1 for plutonium. This result exhibits a gain in detection limit of a factor higher than 10 4 compared to the capillary electrophoresis in standard detection (UV). The studies were made in order to check the capacity of the CE / ICP-MS coupling as a speciation instrument for actinides at trace level and to define the associated analytical procedures. The coupling turned out to be a suited instrument for the determination of absolute electrophoretic mobilities at infinite dilution (physico-chemical property which allows to predict the migration time of an ion under an electrical field in a given electrolyte), for the determination of thermodynamic constants and for the separation of different actinide oxidation states in solution. (author)

  5. Separation of actinides using capillary extraction chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Peterson, Dominic S; Montoya, Velma M

    2009-08-01

    Trace levels of actinides have been separated on capillary extraction chromatography columns. Detection of the actinides was achieved using an inductively coupled plasma mass spectrometer, which was coupled with the extraction chromatography system. In this study, we compare 30-cm long, 4.6 mm i.d. columns to capillary columns (750 microm i.d.) with lengths from 30 cm up to 150 cm. The columns that were tested were packed with TRU resin. We were able to separate a mixture of five actinides ((232)Th, (238)U, (237)Np, (239)Pu, and (241)Am). This work has application to rapid bioassay as well as automated separations of actinide materials.

  6. Structure of the strongly coupled classical plasma in the self-consistent mean spherical approximation

    International Nuclear Information System (INIS)

    Chaturvedi, D.K.; Senatore, G.; Tosi, M.P.

    1980-10-01

    An analytic theory is presented for the static structure factor of the one-component classical plasma at strong couplings. The theory combines the hard-core model of Gillan for short-range correlations in the Coulomb fluid with a semiempirical representation of intermediate-range correlations, through which the requirement of thermodynamic consistency on the ''compressibility'' and the known equation of state of the system are satisfied. Excellent agreement is found with the available computer simulation data on the structure of the fluid. The approach becomes inapplicable at intermediate and weak couplings where effects of penetration in the Coulomb hole of each particle become important. (author)

  7. The concept of coupling impedance in the self-consistent plasma wake field excitation

    International Nuclear Information System (INIS)

    Fedele, R.; Akhter, T.; De Nicola, S.; Migliorati, M.; Marocchino, A.; Massimo, F.; Palumbo, L.

    2016-01-01

    Within the framework of the Vlasov–Maxwell system of equations, we describe the self-consistent interaction of a relativistic charged-particle beam with the surroundings while propagating through a plasma-based acceleration device. This is done in terms of the concept of coupling (longitudinal) impedance in full analogy with the conventional accelerators. It is shown that also here the coupling impedance is a very useful tool for the Nyquist-type stability analysis. Examples of specific physical situations are finally illustrated.

  8. Fundamental studies of the plasma extraction and ion beam formation processes in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Niu, Hongsen.

    1995-01-01

    The fundamental and practical aspects are described for extracting ions from atmospheric pressure plasma sources into an analytical mass spectrometer. Methodologies and basic concepts of inductively coupled plasma mass spectrometry (ICP-MS) are emphasized in the discussion, including ion source, sampling interface, supersonic expansion, slumming process, ion optics and beam focusing, and vacuum considerations. Some new developments and innovative designs are introduced. The plasma extraction process in ICP-MS was investigated by Langmuir measurements in the region between the skimmer and first ion lens. Electron temperature (T e ) is in the range 2000--11000 K and changes with probe position inside an aerosol gas flow. Electron density (n e ) is in the range 10 8 --10 10 -cm at the skimmer tip and drops abruptly to 10 6 --10 8 cm -3 near the skimmer tip and drops abruptly to 10 6 --10 8 cm -3 downstream further behind the skimmer. Electron density in the beam leaving the skimmer also depends on water loading and on the presence and mass of matrix elements. Axially resolved distributions of electron number-density and electron temperature were obtained to characterize the ion beam at a variety of plasma operating conditions. The electron density dropped by a factor of 101 along the centerline between the sampler and skimmer cones in the first stage and continued to drop by factors of 10 4 --10 5 downstream of skimmer to the entrance of ion lens. The electron density in the beam expansion behind sampler cone exhibited a 1/z 2 intensity fall-off (z is the axial position). An second beam expansion originated from the skimmer entrance, and the beam flow underwent with another 1/z 2 fall-off behind the skimmer. Skimmer interactions play an important role in plasma extraction in the ICP-MS instrument

  9. Online Coupling of Flow-Field Flow Fractionation and Single Particle Inductively Coupled Plasma-Mass Spectrometry: Characterization of Nanoparticle Surface Coating Thickness and Aggregation State

    Science.gov (United States)

    Surface coating thickness and aggregation state have strong influence on the environmental fate, transport, and toxicity of engineered nanomaterials. In this study, flow-field flow fractionation coupled on-line with single particle inductively coupled plasma-mass spectrometry i...

  10. Estimation of rare earth elements in gadolinium oxide by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Kumar, Sanjukta A.; Venkataramani, B.; Kotekar, M.K.

    2007-01-01

    A method was developed for the direct determination of trace quantities of rare earth elements (REEs) in gadolinium oxide dissolved in nitric acid by inductively coupled plasma mass spectrometry. The matrix suppression effect of Gd on the ion peak signals of REEs impurities was effectively compensated with spiking In as an internal standard. The recoveries of spiked sample for REEs were found to be in the range of 91-109% by using the proposed method. The relative standard deviation varied between 1.5 to 6%. The methodology had been found to be suitable for the direct determination of trace REEs in Gd 2 O 3 and the results obtained from this method keep in good agreement with that acquired from inductively coupled plasma emission spectrometry. (author)

  11. Self-consistent simulation study on magnetized inductively coupled plasma for 450 mm semiconductor wafer processing

    International Nuclear Information System (INIS)

    Lee, Ho-Jun; Kim, Yun-Gi

    2012-01-01

    The characteristics of weakly magnetized inductively coupled plasma (MICP) are investigated using a self-consistent simulation based on the drift–diffusion approximation with anisotropic transport coefficients. MICP is a plasma source utilizing the cavity mode of the low-frequency branch of the right-hand circularly polarized wave. The model system is 700 mm in diameter and has a 250 mm gap between the radio-frequency window and wafer holder. The model chamber size is chosen to verify the applicability of this type of plasma source to the 450 mm wafer process. The effects of electron density distribution and external axial magnetic field on the propagation properties of the plasma wave, including the wavelength modulation and refraction toward the high-density region, are demonstrated. The restricted electron transport and thermal conductivity in the radial direction due to the magnetic field result in small temperature gradient along the field lines and off-axis peak density profile. The calculated impedance seen from the antenna terminal shows that MICP has a resistance component that is two to threefold higher than that of ICP. This property is practically important for large-size, low-pressure plasma sources because high resistance corresponds to high power-transfer efficiency and stable impedance matching characteristics. For the 0.665 Pa argon plasma, MICP shows a radial density uniformity of 6% within 450 mm diameter, which is much better than that of nonmagnetized ICP.

  12. Quality assurance in the elemental analysis of foods by inductively coupled plasma spectroscopy

    Science.gov (United States)

    Wolnik, Karen A.; Fricke, Fred L.; Gaston, Cynthia M.

    The U.S. Food and Drug Administration, Department of Agriculture, and Environmental Protection Agency are conducting a joint study of elemental background levels in raw agricultural crops. More than three thousand samples have been analysed for 12 elements by inductively coupled plasma-optical emission spectroscopy (ICP). A quality assurance program has been designed to assure the accuracy and reliability of these analyses. The development and rationale for this program are described and illustrated by analytical results.

  13. Numerical methods for TVD transport and coupled relaxing processes in gases and plasmas

    Science.gov (United States)

    Cambier, Jean-Luc

    1990-01-01

    The construction of second-order upwind schemes for nonequilibrium plasmas, for both one- and two-fluid formulations is demonstrated. Coupled relaxation processes, including ionization kinetics and radiative processes and their algorithms for nonequilibrium, multiple temperature conditions are described as well. The paper applies the numerical techniques on some simple test cases, points out critical problems and their solutions, and makes qualitative comparisons with known results, whenever possible.

  14. Study of hard diamond-like carbon films deposited in an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Yu Shiji; Ma Tengcai

    2003-01-01

    Chemical vapor deposition of the hard diamond-like carbon (DLC) films was achieved using an inductively coupled plasma source (ICPS). The microscopy, microhardness, deposition rate and structure characteristic of the DLC films were analyzed. It is shown that the ICPS is suitable for the hard DLC film deposition at relatively low substrate negative bias voltage, and the substrate negative bias voltage greatly affects chemical vapor deposition of the DLC film and its quality

  15. Reduction of plyatomic ion interferences in indictively coupled plasma mass spectrometry with cryogenic desolvation

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Luis C. [Iowa State Univ., Ames, IA (United States)

    1993-09-01

    A desolvation scheme for introducing aqueous and organic samples into an argon inductively coupled plasma is described; the aerosol generated by nebulizer is heated (+140 C) and cooled (-80 C) repeatedly, and the dried aerosol is then injected into the mass spectrometer. Polyatomic ions are greatly suppressed. This scheme was validated with analysis of seawater and urine reference samples. Finally, the removal of organic solvents by cryogenic desolvation was studied.

  16. 2D elemental mapping of sections of human kidney stones using laser ablation inductively-coupled plasma-mass spectrometry: Possibilities and limitations

    Science.gov (United States)

    Vašinová Galiová, Michaela; Čopjaková, Renata; Škoda, Radek; Štěpánková, Kateřina; Vaňková, Michaela; Kuta, Jan; Prokeš, Lubomír; Kynický, Jindřich; Kanický, Viktor

    2014-10-01

    A 213 nm Nd:YAG-based laser ablation (LA) system coupled to quadrupole-based inductively coupled plasma-mass spectrometer and an ArF* excimer-based LA-system coupled to a double-focusing sector field inductively coupled plasma-mass spectrometer were employed to study the spatial distribution of various elements in kidney stones (uroliths). Sections of the surfaces of uroliths were ablated according to line patterns to investigate the elemental profiles for the different urolith growth zones. This exploratory study was mainly focused on the distinguishing of the main constituents of urinary calculus fragments by means of LA-ICP-mass spectrometry. Changes in the ablation rate for oxalate and phosphate phases related to matrix density and hardness are discussed. Elemental association was investigated on the basis of 2D mapping. The possibility of using NIST SRM 1486 Bone Meal as an external standard for calibration was tested. It is shown that LA-ICP-MS is helpful for determination of the mineralogical composition and size of all phases within the analyzed surface area, for tracing down elemental associations and for documenting the elemental content of urinary stones. LA-ICP-MS results (elemental contents and maps) are compared to those obtained with electron microprobe analysis and solution analysis ICP-MS.

  17. Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

    Energy Technology Data Exchange (ETDEWEB)

    Luong, Elise [Iowa State Univ., Ames, IA (United States)

    1999-05-10

    This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 ± 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-trace concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 ± 0.4 ng/g, while the certified value is 11.5 ± 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 ± 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry (GC-combustion-IRMS). Trytophan, myoglobin, and β-cyclodextrin are chosen for the study, initial observation of spectral interference of 13C+ with 12C 1H+ comes from the incomplete dissociation of myoglobin and/or β-cyclodextrin.

  18. Nonlinear electromagnetic fields in 0.5 MHz inductively coupled plasmas

    DEFF Research Database (Denmark)

    Ostrikov, K.N.; Tsakadze, E.L.; Xu, S.

    2003-01-01

    Radial profiles of magnetic fields in the electrostatic (E) and electromagnetic (H) modes of low-frequency (similar to500 kHz) inductively coupled plasmas have been measured using miniature magnetic probes. In the low-power (similar to170 W) E-mode, the magnetic field pattern is purely linear......, with the fundamental frequency harmonics only. After transition to higher-power (similar to1130 W) H-mode, the second-harmonic nonlinear azimuthal magnetic field B-phi(2omega) that is in 4-6 times larger than the fundamental frequency component B-phi(omega), has been observed. A simplified plasma fluid model...... explaining the generation of the second harmonics of the azimuthal magnetic field in the plasma source is proposed. The nonlinear second harmonic poloidal (r-z) rf current generating the azimuthal magnetic field B-phi(2omega) is attributed to nonlinear interactions between the fundamental frequency radial...

  19. Multi-chord fiber-coupled interferometry of supersonic plasma jets (invited)

    International Nuclear Information System (INIS)

    Merritt, Elizabeth C.; Lynn, Alan G.; Gilmore, Mark A.; Thoma, Carsten; Loverich, John; Hsu, Scott C.

    2012-01-01

    A multi-chord fiber-coupled interferometer is being used to make time-resolved density measurements of supersonic argon plasma jets on the Plasma Liner Experiment. The long coherence length of the laser (>10 m) allows signal and reference path lengths to be mismatched by many meters without signal degradation, making for a greatly simplified optical layout. Measured interferometry phase shifts are consistent with a partially ionized plasma in which both positive and negative phase shift values are observed depending on the ionization fraction. In this case, both free electrons and bound electrons in ions and neutral atoms contribute to the index of refraction. This paper illustrates how the interferometry data, aided by numerical modeling, are used to derive total jet density, jet propagation velocity (∼15–50 km/s), jet length (∼20–100 cm), and 3D expansion.

  20. Viscosity of two-dimensional strongly coupled dusty plasma modified by a perpendicular magnetic field.

    Science.gov (United States)

    Feng, Yan; Lin, Wei; Murillo, M S

    2017-11-01

    Transport properties of two-dimensional (2D) strongly coupled dusty plasmas have been investigated in detail, but never for viscosity with a strong perpendicular magnetic field; here, we examine this scenario using Langevin dynamics simulations of 2D liquids with a binary Yukawa interparticle interaction. The shear viscosity η of 2D liquid dusty plasma is estimated from the simulation data using the Green-Kubo relation, which is the integration of the shear stress autocorrelation function. It is found that, when a perpendicular magnetic field is applied, the shear viscosity of 2D liquid dusty plasma is modified substantially. When the magnetic field is increased, its viscosity increases at low temperatures, while at high temperatures its viscosity diminishes. It is determined that these different variational trends of η arise from the different behaviors of the kinetic and potential parts of the shear stress under external magnetic fields.

  1. The Integrated Plasma Simulator: A Flexible Python Framework for Coupled Multiphysics Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Samantha S [ORNL; Elwasif, Wael R [ORNL; Bernholdt, David E [ORNL

    2011-11-01

    High-fidelity coupled multiphysics simulations are an increasingly important aspect of computational science. In many domains, however, there has been very limited experience with simulations of this sort, therefore research in coupled multiphysics often requires computational frameworks with significant flexibility to respond to the changing directions of the physics and mathematics. This paper presents the Integrated Plasma Simulator (IPS), a framework designed for loosely coupled simulations of fusion plasmas. The IPS provides users with a simple component architecture into which a wide range of existing plasma physics codes can be inserted as components. Simulations can take advantage of multiple levels of parallelism supported in the IPS, and can be controlled by a high-level ``driver'' component, or by other coordination mechanisms, such as an asynchronous event service. We describe the requirements and design of the framework, and how they were implemented in the Python language. We also illustrate the flexibility of the framework by providing examples of different types of simulations that utilize various features of the IPS.

  2. Purification of the gas after pyrolysis in coupled plasma-catalytic system

    Directory of Open Access Journals (Sweden)

    Młotek Michał

    2017-12-01

    Full Text Available Gliding discharge and coupled plasma-catalytic system were used for toluene conversion in a gas composition such as the one obtained during pyrolysis of biomass. The chosen catalyst was G-0117, which is an industrial catalyst for methane conversion manufactured by INS Pulawy (Poland. The effects of discharge power, initial concentration of toluene, gas flow rate and the presence of the bed of the G-0117 catalyst on the conversion of C7H8, a model tars compounds were investigated. Conversion of coluene increases with discharge power and the highest one was noted in the coupled plasma-catalytic system. It was higher than that in the homogeneous system of gliding discharge. When applying a reactor with reduced G-0117 and CO (0.15 mol%, CO2 (0.15 mol%, H2 (0.30 mol%, N2 (0.40 mol%, 4000 ppm of toluene and gas flow rate of 1.5 Nm3/h, the conversion of toluene was higher than 99%. In the coupled plasma-catalytic system with G-0117 methanation of carbon oxides was observed.

  3. HEMOFILTRATION AND COUPLED PLASMA FILTRATION ADSORPTION IMPACT ON TACROLIMUS BLOOD CONCENTRATION IN RENAL TRANSPLANT RECIPIENTS

    Directory of Open Access Journals (Sweden)

    A.V. Vatazin

    2014-01-01

    Full Text Available Aim. To study the effect of hemofi ltration and coupled plasma fi ltration adsorption on tacrolimus blood concentration in renal transplant recipients.Methods and results. The study included 8 renal transplant recipients. In these patients immediately after the operation was performed the coupled plasma fi ltration adsorption with hemofiltration using a cartridge Mediasorb to reduce the severity of reperfusion injury. We have found that during this extracorporeal blood correction procedure there was statistically not signifi cant decrease of tacrolimus blood concentration. However, concentration of tacrolimus remained in the therapeutic range even after the procedure and it was not signifi cantly different from the control point С0.Conclusion. Coupled plasma fi ltration adsorption is safe in renal transplant recipients and has no signifi cant impact on tacrolimus blood concentration. However, the downward trend in the concentration of tacrolimus in the course of these procedures, especially in continuous or semicontinuous mode, as well as in patients with low hematocrit and hypoalbuminemia, requires individual monitoring.

  4. Determination of selenoprotein P in human plasma by solid phase extraction and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Bendahl, L.; Sidenius, U.; Gammelgaard, Bente

    2000-01-01

    A method based on solid phase extraction was developed for the determination of selenoprotein P as selenium in human plasma. Separation of selenoprotein P from other selenium-containing proteins was accomplished by immobilized metal-ion affinity chromatography. The selenium content was subsequent...... than 2% in this range. The estimated limit of detection was 2 mu g/l and the experimentally verified quantification limit was 5 mu g/l, giving a relative standard deviation less than 2%. (C) 2000 Elsevier Science B.V. All rights reserved......A method based on solid phase extraction was developed for the determination of selenoprotein P as selenium in human plasma. Separation of selenoprotein P from other selenium-containing proteins was accomplished by immobilized metal-ion affinity chromatography. The selenium content was subsequently...... measured by inductively coupled plasma mass spectrometry (ICP-MS) monitoring the Se-82 isotope. Linear response was observed in the concentration range 0.3-70.8 mu g/l selenium as selenoprotein P with a correlation coefficient of 0.9994. The precision expressed as relative standard deviation was better...

  5. Si-compatible cleaning process for graphene using low-density inductively coupled plasma.

    Science.gov (United States)

    Lim, Yeong-Dae; Lee, Dae-Yeong; Shen, Tian-Zi; Ra, Chang-Ho; Choi, Jae-Young; Yoo, Won Jong

    2012-05-22

    We report a novel cleaning technique for few-layer graphene (FLG) by using inductively coupled plasma (ICP) of Ar with an extremely low plasma density of 3.5 × 10(8) cm(-3). It is known that conventional capacitively coupled plasma (CCP) treatments destroy the planar symmetry of FLG, giving rise to the generation of defects. However, ICP treatment with extremely low plasma density is able to remove polymer resist residues from FLG within 3 min at a room temperature of 300 K while retaining the carbon sp(2)-bonding of FLG. It is found that the carrier mobility and charge neutrality point of FLG are restored to their pristine defect-free state after the ICP treatment. Considering the application of graphene to silicon-based electronic devices, such a cleaning method can replace thermal vacuum annealing, electrical current annealing, and wet-chemical treatment due to its advantages of being a low-temperature, large-area, high-throughput, and Si-compatible process.

  6. Inductively coupled plasma etching of poly-SiC in SF6 chemistries

    Science.gov (United States)

    Kuah, S. H.; Wood, P. C.

    2005-07-01

    A study was made to find a low-cost and robust etching solution for silicon carbide (SiC) using a commercially available inductively coupled plasma etching tool. Sulfur hexafluoride (SF6) was selected because of its high degree of F dissociation and nonhazardous nature. A parametric study of the etching characteristics of poly-SiC in inductively coupled plasma (ICP) SF6 chemistries was performed. Etch chemistry was found to greatly affect etch rate, selectivity, and the postetch surface condition. Etch rates as high as 5884 A˚/min were achieved with high SiC/Cr selectivity (36) using a SF6/CF4/He gas mixture, but the etched surface was relatively rough (134 A˚ rms). He addition was found to increase the SiC etch rate, and this effect is believed to be caused by increased ionization of SF6 in the plasma and the resulting increases in the SF3+ and fluorine (F) radical concentrations. The formation of pillar-like structures and sidewall deposition was observed on the etched SiC surfaces under some conditions. These unwanted etch byproducts exhibited a high concentration of chromium (Cr) and fluorine. However, an argon (Ar) plasma preclean of the substrate, high ICP, and/or bias powers, and CF4 addition reduced the pillar formation significantly.

  7. Initial design for an experimental investigation of strongly coupled plasma behavior in the ATLAS facility

    CERN Document Server

    Munson, C P; Taylor, A J; Trainor, R J; Wood, B P; Wysocki, F J

    1999-01-01

    Summary form only given. Atlas is a high current (~30 MA peak, with a current risetime ~4.5 mu sec), high energy (E/sub stored/=24 MJ, E /sub load/=3-6 MJ), pulsed power facility which is being constructed at Los Alamos National Laboratory with a scheduled completion date in the year 2000. When operational, this facility will provide a platform for experiments in high pressure shocks (>20 Mbar), adiabatic compression ( rho / rho /sub 0/>5, P>10 Mbar), high magnetic fields (~2000 T), high strain and strain rates ( epsilon >200, d epsilon /dt~10/sup 4/ to 10/sup 6/ s/sup -1/), hydrodynamic instabilities of materials in turbulent regimes, magnetized target fusion, equation of state, and strongly coupled plasmas. For the strongly coupled plasma experiments, an auxiliary capacitor bank will be used to generate a moderate density (<0.1 solid), relatively cold (~1 eV) plasma by ohmic heating of a conducting material of interest such as titanium. This target plasma will be compressed against a central column conta...

  8. Review of inductively coupled plasmas: Nano-applications and bistable hysteresis physics

    Science.gov (United States)

    Lee, Hyo-Chang

    2018-03-01

    Many different gas discharges and plasmas exhibit bistable states under a given set of conditions, and the history-dependent hysteresis that is manifested by intensive quantities of the system upon variation of an external parameter has been observed in inductively coupled plasmas (ICPs). When the external parameters (such as discharge powers) increase, the plasma density increases suddenly from a low- to high-density mode, whereas decreasing the power maintains the plasma in a relatively high-density mode, resulting in significant hysteresis. To date, a comprehensive description of plasma hysteresis and a physical understanding of the main mechanism underlying their bistability remain elusive, despite many experimental observations of plasma bistability conducted under radio-frequency ICP excitation. This fundamental understanding of mode transitions and hysteresis is essential and highly important in various applied fields owing to the widespread use of ICPs, such as semiconductor/display/solar-cell processing (etching, deposition, and ashing), wireless light lamp, nanostructure fabrication, nuclear-fusion operation, spacecraft propulsion, gas reformation, and the removal of hazardous gases and materials. If, in such applications, plasma undergoes a mode transition and hysteresis occurs in response to external perturbations, the process result will be strongly affected. Due to these reasons, this paper comprehensively reviews both the current knowledge in the context of the various applied fields and the global understanding of the bistability and hysteresis physics in the ICPs. At first, the basic understanding of the ICP is given. After that, applications of ICPs to various applied fields of nano/environmental/energy-science are introduced. Finally, the mode transition and hysteresis in ICPs are studied in detail. This study will show the fundamental understanding of hysteresis physics in plasmas and give open possibilities for applications to various applied

  9. Coupled two-dimensional edge-plasma and neutral gas modelling of the DIII-D scrape-off-layer

    International Nuclear Information System (INIS)

    Maingi, R.; Gilligan, J.; Hankins, O.; Rensink, M.; Owen, L.; Klepper, C.; Mioduszewski, P.

    1992-01-01

    This paper reports that in order to do consistent scrape-off-layer plasma and neutral transport calculations, the 2-D fluid code, B2 has been externally coupled to the neutral transport code, DEGAS, for Dlll-D. The coupling procedure is similar to recent simulations done for TFTR, Tore Supra, and ClT. An averaged source approach is utilized to allow convergence between the two codes. Initial comparison of plasma quantities between the coupled code set and the B2 code alone shows that a colder, denser plasma may exist at the divertor targets than predicted by the B2 code with its internal recycling model

  10. Eletroforese capilar acoplada à espectrometria com plasma: uma ferramenta eficiente para a especiação Capillary electrophoresis coupled to plasma spectrometry: an efficient tool for speciation

    Directory of Open Access Journals (Sweden)

    Ana Paula G. Gervasio

    2003-01-01

    Full Text Available The most important features of the CE-ICP hyphenation, as well as its advantages and drawbacks as a tool for speciation are discussed. The fundamental principles of capillary electrophoresis and inductively coupled plasma mass spectrometry are also presented. Some applications involving different designs proposed in the literature to couple CE and ICP system for elemental speciation are reviewed.

  11. The Efficiency of Quartz Particles Evaporation in the Argon Plasma Flow of the RF Inductively Coupled Plasma Torch

    Directory of Open Access Journals (Sweden)

    Yu. M. Grishin

    2017-01-01

    Full Text Available Owing to high-power density and high-purity plasma, a RF inductively coupled plasma torch (ICPT is widely used both in research laboratory and in industry. The potential RF ICPT application areas are powders spheroidisation, waste treatment, thermal spraying, etc.In the last decade the investigation was focused on the treatment processes of quartz into polycrystalline silicon. An analysis of these results has shown that the increasing productivity and producing high-purity silicon can be achieved only when using the electrodeless radio-frequency induction plasma torches and in case the optimum conditions for evaporation of SiO2solid particles are realized.Optimization of the RF ICPT design and power parameters calls for a wide range of computational studies. In spite of the fact that to date a large number of efforts to calculate the evaporation efficiency of powder materials have been made, a number of issues, as applied to the problem of obtaining silicon, require further research.In this paper, we present the results of a two-dimensional numerical simulation of the heating and evaporation of quartz particles in the RF ICPT channel with axial flow of gases. The main aim is to determine how the axial position of the central tube (through which the particles are injected into the discharge zone, the dispersion of the quartz powder, the amplitude of the discharge current (and, respectively, flow regimes impact on the evaporation efficiency of quartz particles.The paper presented the numerical modeling results of heating and evaporation processes of quartz particles supplied by transporting gas to the RF ICPT channel with axial gas flow (argon. Defined the impact of the axial position of the central tube, the plasma flow regime, the discharge current, the flow rate of transporting gas, and other parameters on the evaporation efficiency of quartz particles.It is shown that the evaporation efficiency of particles reaches its maximum when their

  12. Coupling systems and designs in use in the Gold and Platinum sector

    CSIR Research Space (South Africa)

    Van der Walt, PG

    2000-11-01

    Full Text Available possibility.” They have developed the “Auto Lock Safety Buffer”. This buffer, they claim: • Is 100 percent compatible with conventional buffers; • Couples automatically; • Replaces the link pin, which is often lost, with a latch (permanently hinged inside....1: Typical semi-automatic ‘dolly’ type coupler operated from either side by gear mounted on both ends of the car………………………………….36 Figure 2.1: Willison Coupler………………………………………………………………37 Figure 3.1: The Hudson Hook and Link coupler………………………………………..38...

  13. On the evolution of jet energy and opening angle in strongly coupled plasma

    International Nuclear Information System (INIS)

    Chesler, Paul M.; Rajagopal, Krishna

    2016-01-01

    We calculate how the energy and the opening angle of jets in N=4 SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet /dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet /dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say the opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N=4 SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N=4 SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. We close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.

  14. Methods for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry

    Science.gov (United States)

    Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN

    2010-08-03

    A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.

  15. Synthesis of ultrafine particles and processing of nano-structured films with inductively coupled plasma

    International Nuclear Information System (INIS)

    Nutsch, G.; Blum, J.; Herrmann, A.; Schwenk, A.; Weiss, K.-H.

    2001-01-01

    The inductively coupled plasma (ICP) at atmospheric pressure is particularly suited for melting and evaporation of materials. The electrodeless ICP can be generated without limitation of the kind of plasma forming gases. Therefore, using an argon-oxygen gas mixture as sheath gas of the ICP nanoparticles can be processed by combustion of metal-organic liquid precursors injected in the hot plasma core. By this way, nanoparticles of alumina, titania and of a perovskite type oxide are produced. The powder particles are collected by an electrostatic filter. They are characterized by a log-normal size distribution with a median diameter of about 10 nm depending on the plasma parameters used. Interesting metastable phases and exactly doped, very pure materials can be obtained. Nanophase coatings synthesized by the ICP are made from the same precursor materials. For depositions, the plasma jet has to be supersonic. Impinging onto the substrate placed near the nozzle thin and dense coatings are obtained. The composition and the grain size of as-deposited coatings are analyzed by XRD. (author)

  16. Study of dual radio frequency capacitively coupled plasma: an analytical treatment matched to an experiment

    Science.gov (United States)

    Saikia, P.; Bhuyan, H.; Escalona, M.; Favre, M.; Wyndham, E.; Maze, J.; Schulze, J.

    2018-01-01

    The behavior of a dual frequency capacitively coupled plasma (2f CCP) driven by 2.26 and 13.56 MHz radio frequency (rf) source is investigated using an approach that integrates a theoretical model and experimental data. The basis of the theoretical analysis is a time dependent dual frequency analytical sheath model that casts the relation between the instantaneous sheath potential and plasma parameters. The parameters used in the model are obtained by operating the 2f CCP experiment (2.26 MHz + 13.56 MHz) in argon at a working pressure of 50 mTorr. Experimentally measured plasma parameters such as the electron density, electron temperature, as well as the rf current density ratios are the inputs of the theoretical model. Subsequently, a convenient analytical solution for the output sheath potential and sheath thickness was derived. A comparison of the present numerical results is done with the results obtained in another 2f CCP experiment conducted by Semmler et al (2007 Plasma Sources Sci. Technol. 16 839). A good quantitative correspondence is obtained. The numerical solution shows the variation of sheath potential with the low and high frequency (HF) rf powers. In the low pressure plasma, the sheath potential is a qualitative measure of DC self-bias which in turn determines the ion energy. Thus, using this analytical model, the measured values of the DC self-bias as a function of low and HF rf powers are explained in detail.

  17. The charge-exchange induced coupling between plasma-gas counterflows in the heliosheath

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    Full Text Available Many hydrodynamic models have been presented which give similar views of the interaction of the solar wind plasma bubble with the counterstreaming partially ionized interstellar medium. In the more recent of these models it is taken into account that the solar and interstellar hydrodynamic flows of neutral atoms and protons are coupled by mass-, momentum-, and energy-exchange terms due to charge exchange processes. We shall reinvestigate the theoretical basis of this coupling here by use of a simplified description of the heliospheric interface and describe the main physics of the H-atom penetration through the more or less standing well-known plasma wall ahead of the heliopause. Thereby we can show that the type of charge exchange coupling terms used in up-to-now hydrodynamic treatments unavoidably leads to an O-type critical point at the sonic point of the H-atom flow, thus not allowing for a continuation of the integration of the hydrodynamic set of differential equations. The remedy for this problem is given by a more accurate formulation of the momentum exchange term for quasi-and sub-sonic H-atom flows. With a refined momentum exchange term derived from basic kinetic Boltzmann principles, we instead arrive at a characteristic equation with an X-type critical point, allowing for a continuous solution from supersonic to subsonic flow conditions. This necessitates that the often treated problem of the propagation of inter-stellar H-atoms through the heliosheath has to be solved using these newly derived, differently effective plasma – gas friction forces. Substantially different results are to be expected from this context for the filtration efficiency of the heliospheric interface.

    Key words. Interplanetary physics (heliopause and solar wind termination; interstellar gas – Ionosphere (plasma temperature and density

  18. The charge-exchange induced coupling between plasma-gas counterflows in the heliosheath

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    2003-06-01

    Full Text Available Many hydrodynamic models have been presented which give similar views of the interaction of the solar wind plasma bubble with the counterstreaming partially ionized interstellar medium. In the more recent of these models it is taken into account that the solar and interstellar hydrodynamic flows of neutral atoms and protons are coupled by mass-, momentum-, and energy-exchange terms due to charge exchange processes. We shall reinvestigate the theoretical basis of this coupling here by use of a simplified description of the heliospheric interface and describe the main physics of the H-atom penetration through the more or less standing well-known plasma wall ahead of the heliopause. Thereby we can show that the type of charge exchange coupling terms used in up-to-now hydrodynamic treatments unavoidably leads to an O-type critical point at the sonic point of the H-atom flow, thus not allowing for a continuation of the integration of the hydrodynamic set of differential equations. The remedy for this problem is given by a more accurate formulation of the momentum exchange term for quasi-and sub-sonic H-atom flows. With a refined momentum exchange term derived from basic kinetic Boltzmann principles, we instead arrive at a characteristic equation with an X-type critical point, allowing for a continuous solution from supersonic to subsonic flow conditions. This necessitates that the often treated problem of the propagation of inter-stellar H-atoms through the heliosheath has to be solved using these newly derived, differently effective plasma – gas friction forces. Substantially different results are to be expected from this context for the filtration efficiency of the heliospheric interface.Key words. Interplanetary physics (heliopause and solar wind termination; interstellar gas – Ionosphere (plasma temperature and density

  19. A validated inductively coupled plasma mass spectrometry (ICP-MS) method for the quantification of total platinum content in plasma, plasma ultrafiltrate, urine and peritoneal fluid.

    Science.gov (United States)

    Lemoine, Lieselotte; Thijssen, Elsy; Noben, Jean-Paul; Adriaensens, Peter; Carleer, Robert; Speeten, Kurt Van der

    2018-04-15

    Oxaliplatin is a platinum (Pt) 1 containing antineoplastic agent that is applied in current clinical practice for the treatment of colon and appendiceal neoplasms. A fully validated, highly sensitive, high throughput inductively coupled plasma mass spectrometry (ICP-MS) method is provided to quantify the total Pt content in plasma, plasma ultrafiltrate, urine and peritoneal fluid. In this ICP-MS approach, the only step of sample preparation is a 1000-fold dilution in 0.5% nitric acid, allowing the analysis of 17 samples per hour. Detection of Pt was achieved over a linear range of 0.01-100 ng/mL. The limit of quantification was 18.0 ng/mL Pt in plasma, 8.0 ng/mL in ultrafiltrate and 6.1 ng/mL in urine and peritoneal fluid. The ICP-MS method was further validated for inter-and intraday precision and accuracy (≤15%), recovery, robustness and stability. Short-term storage of the biofluids, for 14 days, can be performed at -4 °C, -24 °C and -80 °C. As to long-term stability, up to 5 months, storage at -80 °C is encouraged. Furthermore, a timeline assessing the total and unbound Pt fraction in plasma and ultrafiltrate over a period of 45 h is provided. Following an incubation period of 5 h at 37 °C, 19-21% of Pt was recovered in the ultrafiltrate, emphasizing the extensive and rapid binding of oxaliplatin-derived Pt to plasma proteins. The described method can easily be implemented in a routine setting for pharmacokinetic studies in patients treated with oxaliplatin-based hyperthermic intraperitoneal perioperative chemotherapy. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Momentum Broadening in Weakly Coupled Quark-Gluon Plasma (with a view to finding the quasiparticles within liquid quark-gluon plasma)

    CERN Document Server

    D'Eramo, Francesco; Liu, Hong; Rajagopal, Krishna

    2013-01-01

    We calculate P(k_\\perp), the probability distribution for an energetic parton that propagates for a distance L through a medium without radiating to pick up transverse momentum k_\\perp, for a medium consisting of weakly coupled quark-gluon plasma. We use full or HTL self-energies in appropriate regimes, resumming each in order to find the leading large-L behavior. The jet quenching parameter \\hat q is the second moment of P(k_\\perp), and we compare our results to other determinations of this quantity in the literature, although we emphasize the importance of looking at P(k_\\perp) in its entirety. We compare our results for P(k_\\perp) in weakly coupled quark-gluon plasma to expectations from holographic calculations that assume a plasma that is strongly coupled at all length scales. We find that the shape of P(k_\\perp) at modest k_\\perp may not be very different in weakly coupled and strongly coupled plasmas, but we find that P(k_\\perp) must be parametrically larger in a weakly coupled plasma than in a strongl...

  1. Resonant RF network antennas for large-area and large-volume inductively coupled plasma sources

    International Nuclear Information System (INIS)

    Hollenstein, Ch; Howling, A A; Guittienne, Ph

    2013-01-01

    Large-area and large-volume radio frequency (RF) plasmas are produced by different arrangements of an elementary electrical mesh consisting of two conductors interconnected by a capacitor at each end. The obtained cylindrical and planar RF networks are resonant and generate very high RF currents. The input impedance of such RF networks shows the behaviour of an RLC parallel resonance equivalent circuit. The real impedance at the resonance frequency is of great advantage for power matching compared with conventional inductive devices. Changes in the RLC equivalent circuit during the observed E–H transition will allow future interpretation of the plasma–antenna coupling. Furthermore, high power transfer efficiencies are found during inductively coupled plasma (ICP) operation. For the planar RF antenna network it is shown that the E–H transition occurs simultaneously over the entire antenna. The underlying physics of these discharges induced by the resonant RF network antenna is found to be identical to that of the conventional ICP devices described in the literature. The resonant RF network antenna is a new versatile plasma source, which can be adapted to applications in industry and research. (paper)

  2. Determination of trace elements in petroleum products by inductively coupled plasma techniques: A critical review

    Science.gov (United States)

    Sánchez, Raquel; Todolí, José Luis; Lienemann, Charles-Philippe; Mermet, Jean-Michel

    2013-10-01

    The fundamentals, applications and latter developments of petroleum products analysis through inductively coupled plasma optical emission spectrometry (ICP-OES) and mass spectrometry (ICP-MS) are revisited in the present bibliographic survey. Sample preparation procedures for the direct analysis of fuels by using liquid sample introduction systems are critically reviewed and compared. The most employed methods are sample dilution, emulsion or micro-emulsion preparation and sample decomposition. The first one is the most widely employed due to its simplicity. Once the sample has been prepared, an organic matrix is usually present. The performance of the sample introduction system (i.e., nebulizer and spray chamber) depends strongly upon the nature and properties of the solution finally obtained. Many different devices have been assayed and the obtained results are shown. Additionally, samples can be introduced into the plasma by using an electrothermal vaporization (ETV) device or a laser ablation system (LA). The recent results published in the literature showing the feasibility, advantages and drawbacks of latter alternatives are also described. Therefore, the main goal of the review is the discussion of the different approaches developed for the analysis of crude oil and its derivates by inductively coupled plasma (ICP) techniques.

  3. The strongly coupled fourth family and a first-order electroweak phase transition. 1. Quark sector

    International Nuclear Information System (INIS)

    Kikukawa, Yoshio; Kohda, Masaya; Yasuda, Junichiro

    2009-01-01

    In models of dynamical electroweak symmetry breaking due to strongly coupled fourth-family quarks and leptons, their low-energy effective descriptions may involve multiple composite Higgs fields, leading to a possibility that the electroweak phase transition at finite temperature is first-order due to the Coleman-Weinberg mechanism. We examine the behavior of the electroweak phase transition on the basis of the effective renormalizable Yukawa theory, which consists of the fourth-family quarks and two SU(2)-doublet Higgs fields corresponding to the bilinear operators of the fourth-family quarks with/without imposing the compositeness condition. The strength of the first-order phase transition is estimated using the finite-temperature effective potential at one loop with ring improvement. In the Yukawa theory without the compositeness condition, it is found that there is a parameter region where the first-order phase transition is sufficiently strong for the electroweak baryogenesis with the experimentally acceptable Higgs boson and fourth-family quark masses. On the other hand, when the compositeness condition is imposed, the phase transition turns out to be weakly first-order, or possibly second-order, although the result is rather sensitive to the details of the compositeness condition. By combining with the result of the Yukawa theory without the compositeness condition, it is argued that with the fourth-family quark masses in the range of 330-480 GeV, corresponding to the compositeness scale in the range of 1.0-2.3 TeV, the four-fermion interaction among the fourth-family quarks does not lead to the strongly first-order electroweak phase transition. (author)

  4. Holographic current correlators at finite coupling and scattering off a supersymmetric plasma

    Science.gov (United States)

    Hassanain, Babiker; Schvellinger, Martin

    2010-04-01

    By studying the effect of the mathcal {O} (α'3) string theory corrections to type IIB supergravity, including those corrections involving the Ramond-Ramond five-form field strength, we obtain the corrected equations of motion of an Abelian perturbation of the AdS5-Schwarzschild black hole. We then use the gauge theory/string theory duality to examine the coupling-constant dependence of vector current correlators associated to a gauged U(1) sub-group of the global mathcal {R} -symmetry group of strongly-coupled mathcal {N} = 4 super-symmetric Yang-Mills theory at finite temperature. The corrections induce a set of higher-derivative operators for the U(1) gauge field, but their effect is highly suppressed. We thus find that the mathcal {O} (α'3) corrections affect the vector correlators only indirectly, through the corrected metric. We apply our results to investigate scattering off a supersymmetric Yang-Mills plasma at low and high energy. In the latter regime, where Deep Inelastic Scattering is expected to occur, we find an enhancement of the plasma structure functions in comparison with the infinite ’t Hooft coupling result.

  5. Inductively coupled plasma mass spectrometry in the analysis of biological samples and pharmaceutical drugs

    Science.gov (United States)

    Ossipov, K.; Seregina, I. F.; Bolshov, M. A.

    2016-04-01

    Inductively coupled plasma mass spectrometry (ICP-MS) is widely used in the analysis of biological samples (whole blood, serum, blood plasma, urine, tissues, etc.) and pharmaceutical drugs. The shortcomings of this method related to spectral and non-spectral interferences are manifested in full measure in determination of the target analytes in these complex samples strongly differing in composition. The spectral interferences are caused by similarity of masses of the target component and sample matrix components. Non-spectral interferences are related to the influence of sample matrix components on the physicochemical processes taking place during formation and transportation of liquid sample aerosols into the plasma, on the value and spatial distribution of plasma temperature and on the transmission of the ion beam from the interface to mass spectrometer detector. The review is devoted to analysis of different mechanisms of appearance of non-spectral interferences and to ways for their minimization or elimination. Special attention is paid to the techniques of biological sample preparation, which largely determine the mechanisms of the influence of sample composition on the results of element determination. The ways of lowering non-spectral interferences by instrumental parameter tuning and application of internal standards are considered. The bibliography includes 189 references.

  6. Interleaflet Coupling, Pinning, and Leaflet Asymmetry—Major Players in Plasma Membrane Nanodomain Formation

    Science.gov (United States)

    Fujimoto, Toyoshi; Parmryd, Ingela

    2017-01-01

    The plasma membrane has a highly asymmetric distribution of lipids and contains dynamic nanodomains many of which are liquid entities surrounded by a second, slightly different, liquid environment. Contributing to the dynamics is a continuous repartitioning of components between the two types of liquids and transient links between lipids and proteins, both to extracellular matrix and cytoplasmic components, that temporarily pin membrane constituents. This make plasma membrane nanodomains exceptionally challenging to study and much of what is known about membrane domains has been deduced from studies on model membranes at equilibrium. However, living cells are by definition not at equilibrium and lipids are distributed asymmetrically with inositol phospholipids, phosphatidylethanolamines and phosphatidylserines confined mostly to the inner leaflet and glyco- and sphingolipids to the outer leaflet. Moreover, each phospholipid group encompasses a wealth of species with different acyl chain combinations whose lateral distribution is heterogeneous. It is becoming increasingly clear that asymmetry and pinning play important roles in plasma membrane nanodomain formation and coupling between the two lipid monolayers. How asymmetry, pinning, and interdigitation contribute to the plasma membrane organization is only beginning to be unraveled and here we discuss their roles and interdependence. PMID:28119914

  7. Dry etching of ITO by magnetic pole enhanced inductively coupled plasma for display and biosensing devices

    Energy Technology Data Exchange (ETDEWEB)

    Meziani, T. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Vatican City State, Holy See,) (Italy)]. E-mail: tarik.meziani@jrc.it; Colpo, P. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy)]. E-mail: pascal.colpo@jrc.it; Lambertini, V. [Centro Ricerche Fiat, Strada Torino 50, 10043 Orbassano (TO) (Italy); Ceccone, G. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy); Rossi, F. [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Va) (Italy)

    2006-03-15

    The dry etching of indium tin oxide (ITO) layers deposited on glass substrates was investigated in a high density inductively coupled plasma (ICP) source. This innovative low pressure plasma source uses a magnetic core in order to concentrate the electromagnetic energy on the plasma and thus provides for higher plasma density and better uniformity. Different gas mixtures were tested containing mainly hydrogen, argon and methane. In Ar/H{sub 2} mixtures and at constant bias voltage (-100 V), the etch rate shows a linear dependence with input power varying the same way as the ion density, which confirms the hypothesis that the etching process is mainly physical. In CH{sub 4}/H{sub 2} mixtures, the etch rate goes through a maximum for 10% CH{sub 4} indicating a participation of the radicals to the etching process. However, the etch rate remains quite low with this type of gas mixture (around 10 nm/min) because the etching mechanism appears to be competing with a deposition process. With CH{sub 4}/Ar mixtures, a similar feature appeared but the etch rate was much higher, reaching 130 nm/min at 10% of CH{sub 4} in Ar. The increase in etch rate with the addition of a small quantity of methane indicates that the physical etching process is enhanced by a chemical mechanism. The etching process was monitored by optical emission spectroscopy that appeared to be a valuable tool for endpoint detection.

  8. Plasma analysis of inductively coupled impulse sputtering of Cu, Ti and Ni

    Science.gov (United States)

    Loch, D. A. L.; Aranda Gonzalvo, Y.; Ehiasarian, A. P.

    2017-06-01

    Inductively coupled impulse sputtering (ICIS) is a new development in the field of highly ionised pulsed PVD processes. For ICIS the plasma is generated by an internal inductive coil, replacing the need for a magnetron. To understand the plasma properties, measurements of the current and voltage waveforms at the cathode were conducted. The ion energy distribution functions (IEDFs) were measured by energy resolved MS and plasma chemistry was analysed by OES and then compared to a model. The target was operated in pulsed DC mode and the coil was energised by pulsed RF power, with a duty cycle of 7.5%. At a constant pressure (14 Pa) the set peak RF power was varied from 1000-4000 W. The DC voltage to the target was kept constant at 1900 V. OES measurements have shown a monotonic increase in intensity with increasing power. Excitation and ionisation processes were single step for ICIS of Ti and Ni and multi-step for Cu. The latter exhibited an unexpectedly steep rise in ionisation efficiency with power. The IEDFs measured by MS show the material- and time-dependant plasma potential in the range of 10-30 eV, ideal for increased surface mobility without inducing lattice defects. A lower intensity peak, of high energetic ions, is visible at 170 eV during the pulse.

  9. Characterization of stationary and pulsed inductively coupled RF discharges for plasma sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Gans, T [Institute for Plasma and Atomic Physics, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Osiac, M [Institute for Plasma and Atomic Physics, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); O' Connell, D [Institute for Plasma and Atomic Physics, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Kadetov, V A [Institute for Plasma and Atomic Physics, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Czarnetzki, U [Institute for Plasma and Atomic Physics, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Schwarz-Selinger, T [Centre for Interdisciplinary Plasma Science, Max-Planck-Institute for Plasma Physics, 85748 Garching (Germany); Halfmann, H [Institute for Electrical Engineering and Plasma Technology, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany); Awakowicz, P [Institute for Electrical Engineering and Plasma Technology, CPST, Ruhr-Universitaet Bochum, 44780 Bochum (Germany)

    2005-05-01

    Sterilization of bio-medical materials using radio frequency (RF) excited inductively coupled plasmas (ICPs) has been investigated. A double ICP has been developed and studied for homogenous treatment of three-dimensional objects. Sterilization is achieved through a combination of ultraviolet light, ion bombardment and radical treatment. For temperature sensitive materials, the process temperature is a crucial parameter. Pulsing of the plasma reduces the time average heat strain and also provides additional control of the various sterilization mechanisms. Certain aspects of pulsed plasmas are, however, not yet fully understood. Phase resolved optical emission spectroscopy and time resolved ion energy analysis illustrate that a pulsed ICP ignites capacitively before reaching a stable inductive mode. Time resolved investigations of the post-discharge, after switching off the RF power, show that the plasma boundary sheath in front of a substrate does not fully collapse for the case of hydrogen discharges. This is explained by electron heating through super-elastic collisions with vibrationally excited hydrogen molecules.

  10. Rocket experiment in a coupling process between neutral atmosphere and plasma

    Science.gov (United States)

    Watanabe, S.; Liu, H.; Abe, T.; Ono, T.; Otsuka, Y.; Saito, A.; Yamamoto, M.; Yamamoto, M. Y.

    Rocket experiment is carried out to investigate a coupling process between neutral atmosphere and plasma of thermosphere and ionosphere at Kagoshima Space Center KSC of JAXA The rocket launch window is in the evening of July 31 - August 15 2007 Momentum transfer through collisional process of the neutral atmosphere and the plasma is a basic problem of atmospheric circulation and super rotation in the low latitude thermosphere and a medium scale traveling ionospheric disturbance MS-TID occurring in the mid-latitude ionosphere but the direct observation is not yet performed In the rocket experiment we observe plasma drift velocity plasma density and temperature and its fluctuations electric field magnetic field and neutral wind The neutral winds are estimated from the movements of Lithium clouds which are released at altitudes between 150km and 300km and scatter sunlight by resonance scattering with wavelength of 670 nm The Lithium clouds are observed by CCD imagers on ground The plan of rocket experiment ground observation system and science objectives are presented

  11. Capacitively coupled radio-frequency plasmas excited by tailored voltage waveforms

    International Nuclear Information System (INIS)

    Lafleur, T; Delattre, P A; Booth, J P; Johnson, E V

    2013-01-01

    By applying certain types of ‘tailored’ voltage waveforms (TVWs) to capacitively coupled plasmas, a dc self-bias and an asymmetric plasma response can be produced, even in geometrically symmetric reactors. Furthermore, these arbitrary applied waveforms can produce a number of interesting phenomena that are not present in typical single-frequency sinusoidal discharges. This electrical asymmetry effect presents emerging possibilities for the improved control of the ion energy and ion flux in these systems; parameters of vital importance to both etching and deposition applications for materials processing. With a combined research approach utilizing both experimental measurements, and particle-in-cell simulations, we review and extend recent investigations that study a particular class of TVW. The waveforms used have a pulse-type shape and are composed of a varying number of harmonic frequencies. This allows a strong self-bias to be produced, and causes most of the applied voltage to be dropped across a single sheath. Additionally, decreasing the pulse width (by increasing the number of harmonics), allows the plasma density and ion flux to be increased. Simulation and experimental results both demonstrate that this type of waveform can be used to separately control the ion flux and ion energy, while still producing a uniform plasma over large area (50 cm diameter) rf electrodes. (paper)

  12. Simulations of Laser Pulse Coupling and Transmission Efficiency in Plasma Channels

    CERN Document Server

    Giacone, Rodolfo; Cary, John R; Dimitrov, Dimitre; Esarey, Eric; Geddes, Cameron G R; Leemans, Wim; Messmer, Peter

    2005-01-01

    Optical guiding of the laser pulse in a laser wakefield accelerator (LWFA) via plasma channels can greatly increase the interaction length and, hence, the maximun energy of trapped electrons.* Energy efficient coupling of laser pulses from vacuum into plasma channels is very important for optimal LWFA performance. We present 2D particle-in-cell simulations of this problem using the VORPAL code.** Some of the mechanisms considered are enhanced leakage of laser energy transversely through the channel walls, enhanced refraction due to tunneling ionization of neutral gas on the periphery of the gas jet, ionization of neutral gas by transverse wings of the laser pulse and effect of the pulse being off axis of the channel. Using power spectral diagnostics,*** we are able to differentiate between pump depletion and leakage from the channel. The results from our simulations show that for short (≈λp

  13. Simulation of a large size inductively coupled plasma generator and comparison with experimental data

    Science.gov (United States)

    Lei, Fan; Li, Xiaoping; Liu, Yanming; Liu, Donglin; Yang, Min; Yu, Yuanyuan

    2018-01-01

    A two-dimensional axisymmetric inductively coupled plasma (ICP) model with its implementation in the COMSOL (Multi-physics simulation software) platform is described. Specifically, a large size ICP generator filled with argon is simulated in this study. Distributions of the number density and temperature of electrons are obtained for various input power and pressure settings and compared. In addition, the electron trajectory distribution is obtained in simulation. Finally, using experimental data, the results from simulations are compared to assess the veracity of the two-dimensional fluid model. The purpose of this comparison is to validate the veracity of the simulation model. An approximate agreement was found (variation tendency is the same). The main reasons for the numerical magnitude discrepancies are the assumption of a Maxwellian distribution and a Druyvesteyn distribution for the electron energy and the lack of cross sections of collision frequencies and reaction rates for argon plasma.

  14. Violation of the Holographic Viscosity Bound in a Strongly Coupled Anisotropic Plasma

    Science.gov (United States)

    Rebhan, Anton; Steineder, Dominik

    2012-01-01

    We study the conductivity and shear viscosity tensors of a strongly coupled N=4 super-Yang-Mills plasma which is kept anisotropic by a θ parameter that depends linearly on one of the spatial dimensions. Its holographic dual is given by an anisotropic axion-dilaton-gravity background and has recently been proposed by Mateos and Trancanelli as a model for the preequilibrium stage of quark-gluon plasma in heavy-ion collisions. By applying the membrane paradigm which we also check by numerical evaluation of Kubo formula and lowest lying quasinormal modes, we find that the shear viscosity purely transverse to the direction of anisotropy saturates the holographic viscosity bound, whereas longitudinal shear viscosities are smaller, providing the first such example not involving higher-derivative theories of gravity and, more importantly, with fully known gauge-gravity correspondence.

  15. Removal of model proteins by means of low-pressure inductively coupled plasma discharge

    Energy Technology Data Exchange (ETDEWEB)

    Kylian, O; Rauscher, H; Gilliland, D; Bretagnol, F; Rossi, F [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, Via E Fermi 2749, 21027 Ispra (Italy)], E-mail: francois.rossi@jrc.it

    2008-05-07

    Surgical instruments are intended to come into direct contact with the patients' tissues and thus interact with their first immune defence system. Therefore they have to be cleaned, sterilized and decontaminated, in order to prevent any kind of infections and inflammations or to exclude the possibility of transmission of diseases. From this perspective, the removal of protein residues from their surfaces constitutes new challenges, since certain proteins exhibit high resistance to commonly used sterilization and decontamination techniques and hence are difficult to remove without inducing major damages to the object treated. Therefore new approaches must be developed for that purpose and the application of non-equilibrium plasma discharges represents an interesting option. The possibility to effectively remove model proteins (bovine serum albumin, lysozyme and ubiquitin) from surfaces of different materials (Si wafer, glass, polystyrene and gold) by means of inductively coupled plasma discharges sustained in different argon containing mixtures is demonstrated and discussed in this paper.

  16. Removal of model proteins by means of low-pressure inductively coupled plasma discharge

    Science.gov (United States)

    Kylián, O.; Rauscher, H.; Gilliland, D.; Brétagnol, F.; Rossi, F.

    2008-05-01

    Surgical instruments are intended to come into direct contact with the patients' tissues and thus interact with their first immune defence system. Therefore they have to be cleaned, sterilized and decontaminated, in order to prevent any kind of infections and inflammations or to exclude the possibility of transmission of diseases. From this perspective, the removal of protein residues from their surfaces constitutes new challenges, since certain proteins exhibit high resistance to commonly used sterilization and decontamination techniques and hence are difficult to remove without inducing major damages to the object treated. Therefore new approaches must be developed for that purpose and the application of non-equilibrium plasma discharges represents an interesting option. The possibility to effectively remove model proteins (bovine serum albumin, lysozyme and ubiquitin) from surfaces of different materials (Si wafer, glass, polystyrene and gold) by means of inductively coupled plasma discharges sustained in different argon containing mixtures is demonstrated and discussed in this paper.

  17. Collaborative project: research on strongly coupled plasmas. Final technical report for period July 15, 1998--July 14, 2002

    Energy Technology Data Exchange (ETDEWEB)

    Golden, Kenneth I.

    2002-09-16

    The main research accomplishments/findings of the project were the following: (1) Publication of an in-depth review article in Physics of Plasmas on the quasilocalized charge approximation (QLCA) in strongly coupled plasma physics and its application to a variety of Coulomb systems: the model one-component plasma in three and two dimensions, binary ionic mixtures, charged particle bilayers, and laboratory dusty plasmas. (2) In the strongly coupled Coulomb liquid phase, the physical basis of the QLCA, namely, the caging of particles trapped in slowly fluctuating local potential minima, is supported by molecular dynamics simulation of the classical three-dimensional one-component plasma. (3) The QLCA theory, when applied to the analysis of the collective modes in strongly coupled charged particle bilayers, predicts the existence of a remarkable long-wavelength energy gap in the out-of-phase excitation spectrum. More recent theoretical calculations based on the three principal frequency-moment sum rules reveal that the gap persists for arbitrary coupling strengths and over the entire classical to quantum domain all the way down to zero temperature. The existence of the energy gap has now been confirmed in a molecular dynamics simulation of the charged particle bilayer. (4) New compressibility and third-frequency-moment sum rules for multilayer plasmas were formulated and applied to the analysis of the dynamical structure function of charged particle bilayers and superlattices. (5) An equivalent of the Debye-Huckel weak coupling equilibrium theory for classical charged particle bilayer and superlattice plasmas was formulated. (6) The quadratic fluctuation-dissipation theorem (QFDT) for layered classical plasmas was formulated. (7) The QFDT was applied to a powerful kinetic theory-based description of the density-density response function and long-wavelength plasma mode behavior in strongly coupled two-dimensional Coulomb fluids in the weakly degenerate quantum domain.

  18. A generalized electron energy probability function for inductively coupled plasmas under conditions of nonlocal electron kinetics

    Science.gov (United States)

    Mouchtouris, S.; Kokkoris, G.

    2018-01-01

    A generalized equation for the electron energy probability function (EEPF) of inductively coupled Ar plasmas is proposed under conditions of nonlocal electron kinetics and diffusive cooling. The proposed equation describes the local EEPF in a discharge and the independent variable is the kinetic energy of electrons. The EEPF consists of a bulk and a depleted tail part and incorporates the effect of the plasma potential, Vp, and pressure. Due to diffusive cooling, the break point of the EEPF is eVp. The pressure alters the shape of the bulk and the slope of the tail part. The parameters of the proposed EEPF are extracted by fitting to measure EEPFs (at one point in the reactor) at different pressures. By coupling the proposed EEPF with a hybrid plasma model, measurements in the gaseous electronics conference reference reactor concerning (a) the electron density and temperature and the plasma potential, either spatially resolved or at different pressure (10-50 mTorr) and power, and (b) the ion current density of the electrode, are well reproduced. The effect of the choice of the EEPF on the results is investigated by a comparison to an EEPF coming from the Boltzmann equation (local electron kinetics approach) and to a Maxwellian EEPF. The accuracy of the results and the fact that the proposed EEPF is predefined renders its use a reliable alternative with a low computational cost compared to stochastic electron kinetic models at low pressure conditions, which can be extended to other gases and/or different electron heating mechanisms.

  19. Hollow cathode modeling: I. A coupled plasma thermal two-dimensional model

    Science.gov (United States)

    Sary, Gaétan; Garrigues, Laurent; Boeuf, Jean-Pierre

    2017-05-01

    A two-dimensional axisymmetric quasi-neutral fluid model of an emissive hollow cathode that includes neutral xenon, single charge ions and electrons has been developed. The gas discharge is coupled with a thermal model of the cathode into a self-consistent generic model applicable to any hollow cathode design. An exhaustive description of the model assumptions and governing equations is given. Boundary conditions for both the gas discharge and thermal model are clearly specified as well. A new emissive sheath model that is valid for any emissive material and in both space charge and thermionic emission limited regimes is introduced. Then, setting the emitter temperature to an experimentally measured profile, we compare simulation results of the plasma model to measurements available in the literature for NASA NSTAR barium oxide cathode. Qualitative discrepancies between simulation results and measurements are noted in the cathode plume regarding the simulated plasma potential. Motivated by experimental evidence supporting the occurrence of ion acoustic instabilities in the cathode plume, an enhanced model of electron transport in the plume is presented and its consequences analyzed. Using the obtained plasma model, simulated quantities in the plume are qualitatively comparable with measurements. Inside the cathode, the simulated plasma density agrees well with measurements and is within the +/- 50 % experimental uncertainty associated with these measurements. A comparison of simulation results of the full coupled cathode model for the NASA NSTAR cathode with experimental measurements is presented in a companion paper, as well as a physical analysis of the cathode behavior and a parametric study of the influence of the operating point and key design choices.

  20. Study of ICRF wave propagation and plasma coupling efficiency in a linear magnetic mirror device

    Energy Technology Data Exchange (ETDEWEB)

    Peng, S.Y.

    1991-07-01

    Ion Cyclotron Range of Frequency (ICRF) wave propagation in an inhomogeneous axial magnetic field in a cylindrical plasma-vacuum system has historically been inadequately modelled. Previous works either sacrifice the cylindrical geometry in favor of a simpler slab geometry, concentrate on the resonance region, use a single mode to represent the entire field structure, or examine only radial propagation. This thesis performs both analytical and computational studies to model the ICRF wave-plasma coupling and propagation problem. Experimental analysis is also conducted to compare experimental results with theoretical predictions. Both theoretical as well as experimental analysis are undertaken as part of the thesis. The theoretical studies simulate the propagation of ICRF waves in an axially inhomogeneous magnetic field and in cylindrical geometry. Two theoretical analysis are undertaken - an analytical study and a computational study. The analytical study treats the inhomogeneous magnetic field by transforming the (r,z) coordinate into another coordinate system ({rho},{xi}) that allows the solution of the fields with much simpler boundaries. The plasma fields are then Fourier transformed into two coupled convolution-integral equations which are then differenced and solved for both the perpendicular mode number {alpha} as well as the complete EM fields. The computational study involves a multiple eigenmode computational analysis of the fields that exist within the plasma-vacuum system. The inhomogeneous axial field is treated by dividing the geometry into a series of transverse axial slices and using a constant dielectric tensor in each individual slice. The slices are then connected by longitudinal boundary conditions.

  1. Study of ICRF wave propagation and plasma coupling efficiency in a linear magnetic mirror device

    International Nuclear Information System (INIS)

    Peng, S.Y.

    1991-07-01

    Ion Cyclotron Range of Frequency (ICRF) wave propagation in an inhomogeneous axial magnetic field in a cylindrical plasma-vacuum system has historically been inadequately modelled. Previous works either sacrifice the cylindrical geometry in favor of a simpler slab geometry, concentrate on the resonance region, use a single mode to represent the entire field structure, or examine only radial propagation. This thesis performs both analytical and computational studies to model the ICRF wave-plasma coupling and propagation problem. Experimental analysis is also conducted to compare experimental results with theoretical predictions. Both theoretical as well as experimental analysis are undertaken as part of the thesis. The theoretical studies simulate the propagation of ICRF waves in an axially inhomogeneous magnetic field and in cylindrical geometry. Two theoretical analysis are undertaken - an analytical study and a computational study. The analytical study treats the inhomogeneous magnetic field by transforming the (r,z) coordinate into another coordinate system (ρ,ξ) that allows the solution of the fields with much simpler boundaries. The plasma fields are then Fourier transformed into two coupled convolution-integral equations which are then differenced and solved for both the perpendicular mode number α as well as the complete EM fields. The computational study involves a multiple eigenmode computational analysis of the fields that exist within the plasma-vacuum system. The inhomogeneous axial field is treated by dividing the geometry into a series of transverse axial slices and using a constant dielectric tensor in each individual slice. The slices are then connected by longitudinal boundary conditions

  2. Heating mechanism in one-dimensional bounded magnetized inductively coupled plasma

    International Nuclear Information System (INIS)

    Mao Ming; Wang Younian

    2006-01-01

    A self-consistent nonlocal kinetic model has been established to investigate the electron heating mechanism in an one-dimensional bounded magnetized inductively coupled plasma (MICP) under low pressures. The interaction function of electrons with rf electric field and electron energy distribution function (EEDF) are determined by solving the linearized Boltzmann equation incorporating with the Maxwell equations. The numerical results show that the presence of the direct-current (dc) magnetic field plays an important role in the EEDF and high-energy electrons are efficiently heated by the Azbel-Kaner resonances under the anomalous skin-effect conditions

  3. Recent Developments in Trace, Ultratrace and Isotope Ratio Measurements in Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Zahran, N. F.

    2004-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) and Laser Ablation (LA-ICP-MS) are recent techniques for trace, ultratrace and isotope ratio measurements. Main features of these techniques and their figure of merit and capabilities are discussed. An overview of ICP-MS instrument is presented in addition to its precision, accuracy and detection limits. Uses of ICP-MS in environmental monitoring in some cases for detection of some radio nuclides are presented. Two geological applications namely, zircon grains analysis and age dating of Rb-Sr method are presented. Zn elemental and isotopic analyses in blood and serum as a biological application is shown. (Author)

  4. Direct measurement of uranium in seawater by inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Xu, Yihong

    2018-01-01

    A simple method for direct measurement of uranium (238U) in seawater using triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS) was established. The method provides a good analytical performance with respect to detection limit, accuracy, precision and sample throughput. During...... samples taken from large volume of seawater stored in immovable containers for relatively long period (i.e., several months), the uranium concentration and salinity data showed slightly increasing trends with the increase of water depth in the container. Therefore, cautions need to be paid in sampling...

  5. Characterization of silicon isotropic etch by inductively coupled plasma etcher for microneedle array fabrication

    International Nuclear Information System (INIS)

    Ji, J; Tay, F E H; Miao Jianmin; Sun Jianbo

    2006-01-01

    This work investigates the isotropic etching properties in inductively coupled plasma (ICP) etcher for microneedle arrays fabrication. The effects of process variables including powers, gas and pressure on needle structure generation are characterized by factorial design of experiment (DOE). The experimental responses of vertical etching depth, lateral etching length, ratio of vertical etching depth to lateral etching length and photoresist etching rate are reported. The relevance of the etching variables is also presented. The obtained etching behaviours for microneedle structure generation will be applied to develop recipes to fabricate microneedles in designed dimensions

  6. Characterization of silicon isotropic etch by inductively coupled plasma etcher for microneedle array fabrication

    Energy Technology Data Exchange (ETDEWEB)

    Ji, J [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Tay, F E H [Mechanical Engineering National University of Singapore, 119260, Singapore (Singapore); Miao Jianmin [MicroMachines Center, School of Mechanical and Aerospace Engineering, Nanyang Technologica l University, 50 Nanyang Avenue, 639798 (Singapore); Sun Jianbo [MicroMachines Center, School of Mechanical and Aerospace Engineering, Nanyang Technologica l University, 50 Nanyang Avenue, 639798 (Singapore)

    2006-04-01

    This work investigates the isotropic etching properties in inductively coupled plasma (ICP) etcher for microneedle arrays fabrication. The effects of process variables including powers, gas and pressure on needle structure generation are characterized by factorial design of experiment (DOE). The experimental responses of vertical etching depth, lateral etching length, ratio of vertical etching depth to lateral etching length and photoresist etching rate are reported. The relevance of the etching variables is also presented. The obtained etching behaviours for microneedle structure generation will be applied to develop recipes to fabricate microneedles in designed dimensions.

  7. Analysis of GaN etching damage by capacitively coupled RF Ar plasma exposure

    International Nuclear Information System (INIS)

    Kawakami, Retsuo; Inaoka, Takeshi; Minamoto, Shingo; Kikuhara, Yasuyuki

    2008-01-01

    GaN etching damage by capacitively-coupled RF Ar plasma exposure is significantly dependent on gas pressure and exposure time. At a low gas pressure (10 mTorr), the N/Ga ratio decreases by the physical etching effect with increasing exposure time, while the GaN surface morphology is smooth. At a high gas pressure (50 mTorr), there are other effects such as UV radiation, by which the GaN surface morphology becomes rough as the exposure time increases from ∼ 60 min

  8. Drag force in strongly coupled, anisotropic plasma at finite chemical potential

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, Somdeb; Haque, Najmul [Theory Division, Saha Institute of Nuclear Physics,1/AF Bidhannagar, Kolkata-700 064 (India)

    2014-12-30

    We employ methods of gauge/string duality to analyze the drag force on a heavy quark moving through a strongly coupled, anisotropic N=4,SU(N) super Yang-Mills plasma in the presence of a finite U(1) chemical potential. We present numerical results valid for any value of the anisotropy parameter and the U(1) charge density and arbitrary direction of the quark velocity with respect to the direction of anisotropy. In the small anisotropy limit we are also able to furnish analytical results.

  9. Imaginary potential in strongly coupled N = 4 SYM plasma in a magnetic field

    Science.gov (United States)

    Zhang, Zi-qiang; Hou, De-fu

    2018-03-01

    We study the effect of a constant magnetic field on the imaginary part of a quarkonia potential in a strongly-coupled N = 4 SYM plasma. We consider the pair axis to be aligned perpendicularly and parallel to the magnetic field, respectively. For both cases, we find that the presence of the magnetic field tends to enhance the imaginary potential thus decreasing the thermal width. In addition, the magnetic field has a stronger effect on the imaginary potential when the pair axis is perpendicular to the magnetic field rather than parallel.

  10. Determination of trace amounts of cerium in paint by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Wong, K.L.

    1981-01-01

    The determination of Ce in paint by inductively coupled plasma atomic emission spectrometry (ICP-OES) is described, and the detection limit of ICP-OES of 0.0004 ppM is compared with that of other methods. The effects of the major elemental components of paint, Si, Pb, Cr, and Na on the ICP-OES determination of Ce were studied. The interference of 400 ppM of the other ions on the determination of 10 ppM Ce was small (0 to 3% error). The method is applicable to the range of 0.2 to 700 ppM Ce

  11. Drag force in strongly coupled { N }=4 supersymmetric Yang–Mills plasma in a magnetic field

    Science.gov (United States)

    Zhang, Zi-qiang; Ma, Ke; Hou, De-fu

    2018-02-01

    Applying AdS/CFT correspondence, we study the effect of a constant magnetic field { B } on the drag force associated with a heavy quark moving through a strongly-coupled { N }=4 supersymmetric Yang–Mills plasma. The quark is considered moving transverse and parallel to { B }. It is shown that for transverse case, the drag force is linearly dependent on { B } in all regions, while for parallel case, the drag force increases monotonously with increasing { B } and also reveals a linear behavior in the regions of strong { B }. In addition, we find that { B } has a more important effect in the transverse case than for the parallel.

  12. Numerical simulation of nonequilibrium inductive plasma flow coupled with electromagnetic field calculation

    Science.gov (United States)

    Yu, Minghao; Takahashi, Yusuke; Kihara, Hisashi; Abe, Ken-ichi; Yamada, Kazuhiko; Abe, Takashi

    2014-12-01

    Numerical investigation of nonequilibrium inductively coupled plasma (ICP) flow was carried out to study the physical properties of the flow inside a 10-kW ICP torch with the working gas being nitrogen. The flow field was described by two-dimensional compressible axisymmetric Navier-Stokes (N-S) equations that took into account 5 species and 8 chemical reactions. The magnetic vector-potential equations were tightly coupled with the flow-field equations to describe the heating process by inductive discharge. A four-temperature model was adopted to model thermal nonequilibrium process in the discharge torch. The characteristics of ICP flow such as thermal nonequilibrium, inductive discharge, and strong effects of Lorentz forces became clear through the present study.

  13. A method for studies on interactions between a gold-based drug and plasma proteins based on capillary electrophoresis with inductively coupled plasma mass spectrometry detection

    DEFF Research Database (Denmark)

    Nguyen, Tam T T N; Østergaard, Jesper; Gammelgaard, Bente

    2015-01-01

    An analytical method based on capillary electrophoresis (CE) and inductively coupled plasma mass spectrometry (ICP-MS) detection was developed for studies on the interaction of gold-containing drugs and plasma proteins using auranofin as example. A detection limit of 18 ng/mL of auranofin...... corresponding to 5.2 ng/mL Au and a precision of 1.5 % were obtained. Kinetic studies of the interaction between auranofin and protein were performed by incubation in aqueous solutions as well as 20 % human plasma at 37 °C. The reaction of auranofin with human serum albumin (HSA) and plasma proceeded fast; 50...... was the major auranofin-interacting protein in plasma. The CE-ICP-MS method is proposed as a novel approach for kinetic studies of the interactions between gold-based drugs and plasma proteins. Graphical Abstract Development of a CE-ICP-MS based method allows for studies on interaction of the gold containing...

  14. Disturbance zonal and vertical plasma drifts in the Peruvian sector during solar minimum phases

    Science.gov (United States)

    Santos, A. M.; Abdu, M. A.; Souza, J. R.; Sobral, J. H. A.; Batista, I. S.

    2016-03-01

    In the present work, we investigate the behavior of the equatorial F region zonal plasma drifts over the Peruvian region under magnetically disturbed conditions during two solar minimum epochs, one of them being the recent prolonged solar activity minimum. The study utilizes the vertical and zonal components of the plasma drifts measured by the Jicamarca (11.95°S; 76.87°W) incoherent scatter radar during two events that occurred on 10 April 1997 and 24 June 2008 and model calculation of the zonal drift in a realistic ionosphere simulated by the Sheffield University Plasmasphere-Ionosphere Model-INPE. Two main points are focused: (1) the connection between electric fields and plasma drifts under prompt penetration electric field during a disturbed periods and (2) anomalous behavior of daytime zonal drift in the absence of any magnetic storm. A perfect anticorrelation between vertical and zonal drifts was observed during the night and in the initial and growth phases of the magnetic storm. For the first time, based on a realistic low-latitude ionosphere, we will show, on a detailed quantitative basis, that this anticorrelation is driven mainly by a vertical Hall electric field induced by the primary zonal electric field in the presence of an enhanced nighttime E region ionization. It is shown that an increase in the field line-integrated Hall-to-Pedersen conductivity ratio (∑H/∑P), which can arise from precipitation of energetic particles in the region of the South American Magnetic Anomaly, is capable of explaining the observed anticorrelation between the vertical and zonal plasma drifts. Evidence for the particle ionization is provided from the occurrence of anomalous sporadic E layers over the low-latitude station, Cachoeira Paulista (22.67°S; 44.9°W)—Brazil. It will also be shown that the zonal plasma drift reversal to eastward in the afternoon two hours earlier than its reference quiet time pattern is possibly caused by weakening of the zonal wind

  15. Drift zonal plasma ionospheric in the Brazilian sector during a period of extreme low solar activity

    Science.gov (United States)

    Abalde Guede, Jose Ricardo; Tardelli-Coelho, Flavia Elaine

    2016-07-01

    The zonal drift velocities of the ionospheric plasma irregularities of large scale were analyzed; these irregularities were observed using optical emission techniques OI 630.0 nm obtained by photometers imagers installed in two locations on the campus of Urbanova UNIVAP in São José dos Campos - SP designated SJC and Campus ULBRA in Palmas - TO cited as PAL. Data were collected from five years, from 2006 to 2010, low solar activity period. Of the total of 337 nights in SJC and 329 nights in PAL analyzed were selected a total of 18 nights of significant plasma bubble occurrences, 9 nights in SJC and 9 nights in PAL, and studied under two conditions: considering fixed altitude of 280 km OI emission layer of 630.0 nm and calculating the height of this variable layer over each night analyzed. To find these varying altitudes along each night we were assisted with the analysis of CADI digital ionosonde data operating in conjunction with the imaging photometer in its observatory. The radio data available in digisonde allowed to do the analysis on 12 variables altitudes of 18 nights studied for fixed altitude; this occurred because of scattering present in ionograms for those nights and times, due to the presence of plasma bubbles in the study through the of the observatory zenith. Quantitative analysis determined the drift velocity zone for each of the analyzed bubbles 18 nights during the given fixed height and 12 nights evaluating varying altitudes along each night. The means were obtained nights analyzed in each observatory for both methods; SJC in the average velocities is derived from the plasma zone 9 nights bubbles analyzed in the method is fixed altitude 84 ± 18 m / s in the case of PAL the average velocities found is 87 ± 12 m / s. In the other case with variable altitude emission to SJC 8 nights analyzed, we reached a mean value of 87 ± 12 m / s, and for PAL, 4 of 9 nights initially selected, the average speed of the zonal drift plasma bubbles were found 85

  16. A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)

    Science.gov (United States)

    Tarik, Mohamed; Foppiano, Debora; Hess, Adrian; Ludwig, Christian

    2017-01-01

    A large variety of analytical methods are available to characterize particles in aerosols and suspensions. The choice of the appropriate technique depends on the properties to be determined. In many fields information about particle size and chemical composition are of great importance. While in aerosol techniques particle size distributions of gas-borne particles are determined online, their elemental composition is commonly analyzed offline after an appropriate sampling and preparation procedure. To obtain both types of information online and simultaneously, a hyphenated setup was recently developed, including a Scanning Mobility Particle Sizer (SMPS) and an Inductively Coupled Plasma Mass Spectrometer (ICPMS). This allows first to classify the particles with respect to their mobility diameter, and then to determine their number concentration and elemental composition in parallel. A Rotating Disk Diluter (RDD) is used as the introduction system, giving more flexibility regarding the use of different aerosol sources. In this work, a practical guide is provided describing the different steps for establishing this instrumentation, and how to use this analysis tool. The versatility of this hyphenated technique is demonstrated in example measurements on three different aerosols generated out of a) a salt solution, b) a suspension, and c) emitted by a thermal process. PMID:28745635

  17. Information-theoretic measures of hydrogen-like ions in weakly coupled Debye plasmas

    Science.gov (United States)

    Zan, Li Rong; Jiao, Li Guang; Ma, Jia; Ho, Yew Kam

    2017-12-01

    Recent development of information theory provides researchers an alternative and useful tool to quantitatively investigate the variation of the electronic structure when atoms interact with the external environment. In this work, we make systematic studies on the information-theoretic measures for hydrogen-like ions immersed in weakly coupled plasmas modeled by Debye-Hückel potential. Shannon entropy, Fisher information, and Fisher-Shannon complexity in both position and momentum spaces are quantified in high accuracy for the hydrogen atom in a large number of stationary states. The plasma screening effect on embedded atoms can significantly affect the electronic density distributions, in both conjugate spaces, and it is quantified by the variation of information quantities. It is shown that the composite quantities (the Shannon entropy sum and the Fisher information product in combined spaces and Fisher-Shannon complexity in individual space) give a more comprehensive description of the atomic structure information than single ones. The nodes of wave functions play a significant role in the changes of composite information quantities caused by plasmas. With the continuously increasing screening strength, all composite quantities in circular states increase monotonously, while in higher-lying excited states where nodal structures exist, they first decrease to a minimum and then increase rapidly before the bound state approaches the continuum limit. The minimum represents the most reduction of uncertainty properties of the atom in plasmas. The lower bounds for the uncertainty product of the system based on composite information quantities are discussed. Our research presents a comprehensive survey in the investigation of information-theoretic measures for simple atoms embedded in Debye model plasmas.

  18. Coupling between reconnection and Kelvin-Helmholtz instabilities in collisionless plasmas

    Directory of Open Access Journals (Sweden)

    D. Grasso

    2009-04-01

    Full Text Available In a collisionless plasma, when reconnection instability takes place, strong shear flows may develop. Under appropriate conditions these shear flows become unstable to the Kelvin-Helmholtz instability. Here, we investigate the coupling between these instabilities in the framework of a four-field model. Firstly, we recover the known results in the low β limit, β being the ratio between the plasma and the magnetic pressure. We concentrate our attention on the dynamical evolution of the current density and vorticity sheets which evolve coupled together according to a laminar or a turbulent regime. A three-dimensional extension in this limit is also discussed. Secondly, we consider finite values of the β parameter, allowing for compression of the magnetic and velocity fields along the ignorable direction. We find that the current density and vorticity sheets now evolve separately. The Kelvin-Helmholtz instability involves only the vorticity field, which ends up in a turbulent regime, while the current density maintains a laminar structure.

  19. Trace metal analysis of road dust by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Powell, M.J.; Liu, L.; Gnanalingham, N.; Peters, L.

    2000-01-01

    Dust from roads in an air impingement zone close to anthropogenic sources of air pollutants can be a concern for people living in the immediate vicinity. The Ministry of the Environment (MOE) has conducted a case study to monitor the concentration of uranium, strontium, thorium and arsenic in road dust from one such area. A method for the analysis of road dust by inductively coupled plasma mass spectrometry (ICP-MS) has been developed with detection limits in the ng/1 range. A digestion technique has been developed by conducting experiments using single and combinations of acids in open-vessel wet digestions. Accuracy has been determined by the use of matrix representative certified reference materials (CRMs). Digestion precision was determined by elemental concentration measurements of the most representative CRM through replicates. Spike recovery data were from 95% to 110% for all elements, and inter-method comparison studies between hydride generation atomic absorption spectrometry (AAS) inductively coupled plasma atomic emission spectrometry (ICP-AES) and ICP-MS for arsenic and strontium show good agreement. (author)

  20. COMPRESSIBLE RELATIVISTIC MAGNETOHYDRODYNAMIC TURBULENCE IN MAGNETICALLY DOMINATED PLASMAS AND IMPLICATIONS FOR A STRONG-COUPLING REGIME

    Energy Technology Data Exchange (ETDEWEB)

    Takamoto, Makoto [Department of Earth and Planetary Science, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo, 113-0033 (Japan); Lazarian, Alexandre, E-mail: mtakamoto@eps.s.u-tokyo.ac.jp, E-mail: alazarian@facstaff.wisc.edu [Department of Astronomy, University of Wisconsin, 475 North Charter Street, Madison, WI 53706 (United States)

    2016-11-10

    In this Letter, we report compressible mode effects on relativistic magnetohydrodynamic (RMHD) turbulence in Poynting-dominated plasmas using three-dimensional numerical simulations. We decomposed fluctuations in the turbulence into 3 MHD modes (fast, slow, and Alfvén) following the procedure of mode decomposition in Cho and Lazarian, and analyzed their energy spectra and structure functions separately. We also analyzed the ratio of compressible mode to Alfvén mode energy with respect to its Mach number. We found the ratio of compressible mode increases not only with the Alfvén Mach number, but also with the background magnetization, which indicates a strong coupling between the fast and Alfvén modes. It also signifies the appearance of a new regime of RMHD turbulence in Poynting-dominated plasmas where the fast and Alfvén modes are strongly coupled and, unlike the non-relativistic MHD regime, cannot be treated separately. This finding will affect particle acceleration efficiency obtained by assuming Alfvénic critical-balance turbulence and can change the resulting photon spectra emitted by non-thermal electrons.

  1. Inductively coupled plasma-mass spectrometry: an initial assessment of the VG isotopes Plasmaquad

    International Nuclear Information System (INIS)

    Brown, R.M.; Pickford, C.J.

    1985-04-01

    The Chemical Analysis Group has been approached by a British Scientific instrument maker regarding the possibility of the group participating in a Department of Trade and Industry sponsored scheme whereby we would have a 12 month period to assess the advantages and disadvantages of a new analytical technique, Inductively Coupled Plasma-Mass Spectrometry. This report details our initial assessment of the instrument, carried out in order to decide whether to participate in the scheme. We have attempted to discover whether the instrument meets the claims made of it in advertising literature, and have attempted to compare the technique with another, proven technique, Inductively Coupled Plasma - Optical Emission Spectroscopy. The Plasmaquad offers excellent sensitivity for almost all of the elements of the periodic table, giving a distinct improvement over the Chemical Analysis Group's present capabilities for many elements. The isotope ratio measuring ability is important, as the Group has no such capability at the moment and a demand for this type of measurement is foreseen. Our conclusions, while inevitably somewhat subjective, form the basis for recommending Harwell to participate in the scheme. (author)

  2. Minimally-invasive Laser Ablation Inductively Coupled Plasma Mass Spectrometry analysis of model ancient copper alloys

    Energy Technology Data Exchange (ETDEWEB)

    Walaszek, Damian [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Senn, Marianne; Wichser, Adrian [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Faller, Markus [Laboratory for Jointing Technology and Corrosion, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland); Wagner, Barbara; Bulska, Ewa [University of Warsaw, Faculty of Chemistry, Biological and Chemical Research Centre, Żwirki i Wigury 101, 02-089 Warszawa (Poland); Ulrich, Andrea [Laboratory for Analytical Chemistry, Swiss Federal Laboratories for Materials Science and Technology, Überlandstrasse 129, CH-8600 Dübendorf (Switzerland)

    2014-09-01

    This work describes an evaluation of a strategy for multi-elemental analysis of typical ancient bronzes (copper, lead bronze and tin bronze) by means of laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS).The samples originating from archeological experiments on ancient metal smelting processes using direct reduction in a ‘bloomery’ furnace as well as historical casting techniques were investigated with the use of the previously proposed analytical procedure, including metallurgical observation and preliminary visual estimation of the homogeneity of the samples. The results of LA-ICPMS analysis were compared to the results of bulk composition obtained by X-ray fluorescence spectrometry (XRF) and by inductively coupled plasma mass spectrometry (ICPMS) after acid digestion. These results were coherent for most of the elements confirming the usefulness of the proposed analytical procedure, however the reliability of the quantitative information about the content of the most heterogeneously distributed elements was also discussed in more detail. - Highlights: • The previously proposed procedure was evaluated by analysis of model copper alloys. • The LA-ICPMS results were comparable to the obtained by means of XRF and ICPMS. • LA-ICPMS results indicated the usefulness of the proposed analytical procedure.

  3. Excellent Silicon Surface Passivation Achieved by Industrial Inductively Coupled Plasma Deposited Hydrogenated Intrinsic Amorphous Silicon Suboxide

    Directory of Open Access Journals (Sweden)

    Jia Ge

    2014-01-01

    Full Text Available We present an alternative method of depositing a high-quality passivation film for heterojunction silicon wafer solar cells, in this paper. The deposition of hydrogenated intrinsic amorphous silicon suboxide is accomplished by decomposing hydrogen, silane, and carbon dioxide in an industrial remote inductively coupled plasma platform. Through the investigation on CO2 partial pressure and process temperature, excellent surface passivation quality and optical properties are achieved. It is found that the hydrogen content in the film is much higher than what is commonly reported in intrinsic amorphous silicon due to oxygen incorporation. The observed slow depletion of hydrogen with increasing temperature greatly enhances its process window as well. The effective lifetime of symmetrically passivated samples under the optimal condition exceeds 4.7 ms on planar n-type Czochralski silicon wafers with a resistivity of 1 Ωcm, which is equivalent to an effective surface recombination velocity of less than 1.7 cms−1 and an implied open-circuit voltage (Voc of 741 mV. A comparison with several high quality passivation schemes for solar cells reveals that the developed inductively coupled plasma deposited films show excellent passivation quality. The excellent optical property and resistance to degradation make it an excellent substitute for industrial heterojunction silicon solar cell production.

  4. Charging-delay effect on longitudinal dust acoustic shock wave in strongly coupled dusty plasma

    International Nuclear Information System (INIS)

    Ghosh, Samiran; Gupta, M.R.

    2005-01-01

    Taking into account the charging-delay effect, the nonlinear propagation characteristics of longitudinal dust acoustic wave in strongly coupled collisional dusty plasma described by generalized hydrodynamic model have been investigated. In the 'hydrodynamic limit', a Korteweg-de Vries Burger (KdVB) equation with a damping term arising due to dust-neutral collision is derived in which the Burger term is proportional to the dissipation due to dust viscosity through dust-dust correlation and charging-delay-induced anomalous dissipation. On the other hand, in the 'kinetic limit', a KdVB equation with a damping term and a nonlocal nonlinear forcing term arising due to memory-dependent strong correlation effect of dust fluid is derived in which the Burger term depends only on the charging-delay-induced dissipation. Numerical solution of integrodifferential equations reveals that (i) dissipation due to dust viscosity and principally due to charging delay causes excitation of the longitudinal dust acoustic shock wave in strongly coupled dusty plasma and (ii) dust-neutral collision does not appear to play any direct role in shock formation. The condition for the generation of shock is also discussed briefly

  5. Optimization of plasma sampling depth and aerosol gas flow rates for single particle inductively coupled plasma mass spectrometry analysis.

    Science.gov (United States)

    Kálomista, Ildikó; Kéri, Albert; Galbács, Gábor

    2017-09-01

    We performed experiments to assess the separate and also the combined effect of the sampling depth and the aerosol gas flow rates on the signal formation in single particle inductively coupled plasma mass spectrometry (spICP-MS) measurements by using dispersions containing Ag and Au NPs. It was found that the NP signal can significantly be improved by the optimization of the sampling depth. With respect to the "robust" setting, a signal improvement of nearly 100% could be achieved, which translates into a 25-30% improvement in size detection limits. It was also found that the shape of the spICP-MS signal histograms also change with the change of the plasma sampling depth. It was demonstrated that nanoparticle peak separation can also be significantly enhanced by using sampling depth optimization. The effect of the aerosol dilution gas flow, now standard in most ICP-MS instruments, on the spICP-MS signal formation was also studied for the first time in the literature, as this flow was hoped to make spICP-MS measurements more practical and faster via the on-line dilution of the aerosol generated from nano-dispersions. Our experimental results revealed that the dilution gas flow can only be used for a moderate aerosol dilution in spICP-MS measurements, if the gas flow going to the pneumatic nebulizer is proportionally lowered at the same time. This however was found to cause a significant worsening in the operation of the sample introduction system, which gives rise to a strong NP signal loss. Thus it was concluded that the use of the aerosol dilution gas flow, in its present form, can not be suggested for spICP-MS analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Radio frequency energy coupling to high-pressure optically pumped nonequilibrium plasmas

    International Nuclear Information System (INIS)

    Plonjes, Elke; Palm, Peter; Lee, Wonchul; Lempert, Walter R.; Adamovich, Igor V.

    2001-01-01

    This article presents an experimental demonstration of a high-pressure unconditionally stable nonequilibrium molecular plasma sustained by a combination of a continuous wave CO laser and a sub-breakdown radio frequency (rf) electric field. The plasma is sustained in a CO/N 2 mixture containing trace amounts of NO or O 2 at pressures of P=0.4 - 1.2atm. The initial ionization of the gases is produced by an associative ionization mechanism in collisions of two CO molecules excited to high vibrational levels by resonance absorption of the CO laser radiation with subsequent vibration-vibration (V-V) pumping. Further vibrational excitation of both CO and N 2 is produced by free electrons heated by the applied rf field, which in turn produces additional ionization of these species by the associative ionization mechanism. In the present experiments, the reduced electric field, E/N, is sufficiently low to preclude field-induced electron impact ionization. Unconditional stability of the resultant cold molecular plasma is enabled by the negative feedback between gas heating and the associative ionization rate. Trace amounts of nitric oxide or oxygen added to the baseline CO/N 2 gas mixture considerably reduce the electron - ion dissociative recombination rate and thereby significantly increase the initial electron density. This allows triggering of the rf power coupling to the vibrational energy modes of the gas mixture. Vibrational level populations of CO and N 2 are monitored by infrared emission spectroscopy and spontaneous Raman spectroscopy. The experiments demonstrate that the use of a sub-breakdown rf field in addition to the CO laser allows an increase of the plasma volume by about an order of magnitude. Also, CO infrared emission spectra show that with the rf voltage turned on the number of vibrationally excited CO molecules along the line of sight increase by a factor of 3 - 7. Finally, spontaneous Raman spectra of N 2 show that with the rf voltage the vibrational

  7. A study on the fusion reactor - Study of ICRF coupling in the KAIST tokamak plasma

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Duk In; Chang, Hong Young; Lee, Sun Chil; Jun, Sang Jin; Kwon, Gi Chung; Seo, Sung Hun; Heo, Sung Hoi; You, Kwang Il; Song, Soo Bin; Lee, Sung Chul; Kim, Min Chul; Lee, Chan Hui [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1996-09-01

    Research objectives are to design and fabricate the antenna, measure t property of absorption transmitted to the plasma, and research the physical phenomena about the ICRF coupling, Main heating method is ohmic heating at the KAIST tokamak. The power of the plasma produced by ohmic heating is about 100 kW. Because the toroidal field is 5 {approx} 8 kG, the RF system`s output power is about 10 kW and frequency range is 7 {approx} 30 MHz. In the first year, a 1 kW RF preamplifier was bought. In this year, a CW 2 kW RF main amp. and RF power monitoring system was bought. In the research on antenna, we study the method how to measure electric field emitted from antenna using piezo elements. The matching network composed of two VVC (35 kV), 100 {approx} 1000 pF match firmly up to 50 kW power. We studied the measurement method of antenna impedance theoretically, and measured power efficiency and antenna impedance in the helicon plasma. 32 refs., 5 tabs., 29 figs. (author)

  8. Coupled plasma-neutral transport model for the scrape-off region

    International Nuclear Information System (INIS)

    Galambos, J.D.; Peng, Y.K.M.; Heifetz, D.

    1985-03-01

    Analysis of the scrape-off region requires treatment of the plasma transport along and across the field lines and inclusion of the neutral transport effects. A method for modeling the scrape-off region that is presented here uses separate models for each of these aspects that are coupled together through an iteration procedure that requires only minimal numerical effort. The method is applied here to estimate the neutral pumping rates in the pump-limiter and divertor options for a proposed deuterium-tritium (D-T) ignition experiment. High neutral recycling in the vicinity of the neutralizer plate dramatically affects pumping rates for both the pump-limiter and divertor. In both cases, the plasma flow into the channel surrounding the neutralizer plate is greatly reduced by the neutral recycling. The fraction of this flow that is pumped can be large (> 50%), but in general it is dependent on the particular geometry and plasma conditions. It is estimated that pumping speeds approximately greater than 10 5 L/s are adequate for the exhaust requirements in the pump-limiter and the divertor cases. Also, high neutral recycling on the front surface of the limiter tends to increase the neutral pumping rate

  9. Analytical capabilities of an inductively coupled plasma Mattauch Herzog mass spectrometer

    Science.gov (United States)

    Solyom, David A.; Gron, Ole A.; Barnes, James H., IV; Hieftje, Gary M.

    2001-09-01

    An inductively coupled plasma (ICP) has been coupled to a custom-designed Mattauch-Herzog mass spectrometer, replacing a glow-discharge source used in earlier research. Adaptation to an ICP source required significant modifications to address concerns regarding shielding from RF radiation and coupling between the ICP and mass spectrometer. The detrimental impact of fringing magnetic fields on the earlier performance of the instrument's detector has also been addressed. Current figures of merit utilizing ultrasonic nebulization include sensitivities in the 10 8-10 9 cps ppm -1 isotope -1 regime and detection limits of 1-500 pg/l (ppq). Isotope-ratio accuracy and precision are 1% relative error and 1-2% relative standard deviation, respectively. Resolving power (5% valley) exceeds 400. Unfortunately, spectral peak shapes are somewhat disappointing and lead to abundance sensitivity values in the 10 3-10 4 range. Although the instrument is designed for use with a multichannel array detector, all results reported here were obtained in scanning mode to separate limitations of the spectrometer from those of the detector.

  10. Jeans instability in collisional strongly coupled dusty plasma with radiative condensation and polarization force

    Energy Technology Data Exchange (ETDEWEB)

    Prajapati, R. P., E-mail: prajapati-iter@yahoo.co.in; Bhakta, S. [Department of Pure and Applied Physics, Guru Ghasidas Central University, Bilaspur-495009 (C.G.) (India); Chhajlani, R. K. [Retired from School of Studies in Physics, Vikram University, Ujjain-456010 (M.P.) (India)

    2016-05-15

    The influence of dust-neutral collisions, polarization force, and electron radiative condensation is analysed on the Jeans (gravitational) instability of partially ionized strongly coupled dusty plasma (SCDP) using linear perturbation (normal mode) analysis. The Boltzmann distributed ions, dynamics of inertialess electrons, charged dust and neutral particles are considered. Using the plane wave solutions, a general dispersion relation is derived which is modified due to the presence of dust-neutral collisions, strong coupling effect, polarization force, electron radiative condensation, and Jeans dust/neutral frequencies. In the long wavelength perturbations, the Jeans instability criterion depends upon strong coupling effect, polarization interaction parameter, and thermal loss, but it is independent of dust-neutral collision frequency. The stability of the considered configuration is analysed using the Routh–Hurwitz criterion. The growth rates of Jeans instability are illustrated, and stabilizing influence of viscoelasticity and dust-neutral collision frequency while destabilizing effect of electron radiative condensation, polarization force, and Jeans dust-neutral frequency ratio is observed. This work is applied to understand the gravitational collapse of SCDP with dust-neutral collisions.

  11. Sulfur analysis by inductively coupled plasma-mass spectrometry: A review

    Energy Technology Data Exchange (ETDEWEB)

    Giner Martínez-Sierra, J.; Galilea San Blas, O.; Marchante Gayón, J.M.; García Alonso, J.I., E-mail: jiga@uniovi.es

    2015-06-01

    In recent years the number of applications of sulfur (S) analysis using inductively coupled plasma mass spectrometry (ICP-MS) as detector has increased significantly. In this article we describe in some depth the application of ICP-MS for S analysis with emphasis placed on the sulfur-specific detection by hyphenated techniques such as LC, GC, CE and LA coupled on-line to ICP-MS. The different approaches available for sulfur isotope ratio measurements by ICP-MS are also detailed. Particular attention has been paid to the quantification of peptides/proteins and the analysis of metallopeptides/metalloproteins via sulfur by LC–ICP-MS. Likewise, the speciation analysis of metal-based pharmaceuticals and metallodrugs and non-metal selective detection of pharmaceuticals via S are highlighted. Labeling procedures for metabolic applications are also included. Finally, the measurement of natural variations in S isotope composition with multicollector ICP-MS instruments is also covered in this review. - Highlights: • Emphasis placed on the sulfur-specific detection by chromatographic techniques coupled on-line to ICP-MS. • Different instrumental approaches available for sulfur measurements by ICP-MS. • Quantification of proteins and the analysis of metalloproteins via sulfur by LC-ICP-MS. • Labelling procedures for metabolic applications are also included. • The measurement of natural variations in S isotope composition with multicollector ICP-MS.

  12. Neutral gas temperatures measured within a high-density, inductively coupled plasma abatement device

    International Nuclear Information System (INIS)

    Tonnis, Eric J.; Graves, David B.

    2002-01-01

    The neutral temperature within a cylindrical, inductively coupled plasma source has been studied for rare gas and molecular plasmas using the technique of optical emission thermometry. By adding small quantities of N 2 to the gas feeds as an actinometer, the neutral temperature of the discharge can be estimated by simulation and fitting of the rotationally unresolved second positive band (C 3 Π u -B 3 Π g ). In this work, the neutral temperature was estimated using this technique for flowing discharges of argon, helium, neon, nitrogen, and oxygen as a function of pressure and power. It was found that the neutral temperature for all of the discharges studied increased roughly proportional to the logarithm of the pressure. An increase in neutral temperature was also observed with increases in power; however, the dependence did not follow a simple functional form. The rare gases exhibited temperatures significantly above room temperature under high power (1200 W) and high pressure (∼1 Torr) conditions with argon approaching 2000 K. Molecular discharges such as N 2 and O 2 exhibited significantly higher temperatures (approaching 2500 K) than the rare gases even though they are expected to have lower plasma densities at the same pressure and power. It is believed that Franck-Condon heating of the gases during electron impact dissociation, vibrational excitation/thermalization, and exothermic wall reactions may all play important roles in producing such elevated temperatures. Simple, zero-dimensional plasma modeling indicates that neutral temperature elevation will result in significant increases in discharge electron temperature and electron-impact reaction rate coefficients under the same operating conditions

  13. Surface properties of indium tin oxide treated by Cl2 inductively coupled plasma

    International Nuclear Information System (INIS)

    He, Kongduo; Yang, Xilu; Yan, Hang; Gong, Junyi; Zhong, Shaofeng; Ou, Qiongrong; Liang, Rongqing

    2014-01-01

    Graphical abstract: - Highlights: • The work function of chlorinated ITO increases initially by up to 1 eV. • The chlorinated ITO keeps an increment of work function of 0.3 eV after 100 days. • The WF decrease curves can be fitted with double exponential functions. • The desorption of unstable Cl in the surface leads to the rapid decrease of WF. • The core levels of In 3d5 and Sn 3d5 and O 1s shift toward higher binding energies. - Abstract: The effects of Cl 2 inductively coupled plasma (ICP) treatment on the time dependence of work function (WF) and surface properties of indium tin oxide (ITO) were investigated. Kelvin probe (KP) measurements show that the WF after Cl 2 ICP treatment is close to 5.9 eV. The WF decrease curve of Cl 2 plasma treated ITO is fitted with double exponential functions with an adjusted R-square of 0.99. The mechanism under the decrease process is discussed by X-ray photoelectron spectroscopy (XPS). The ITO WF decrease after Cl 2 ICP treatment performs much better than that after O 2 ICP treatment and the chlorinated ITO keeps a WF increment of 0.3 eV compared with that without plasma treatment after 100 days. Other properties of chlorinated ITO surface such as morphology and transmittance change slightly. The results are significant for the understanding of degradation of Cl 2 plasma treated ITO and the fabrication of organic semiconductor devices

  14. Novel high-frequency energy-efficient pulsed-dc generator for capacitively coupled plasma discharge

    Science.gov (United States)

    Mamun, Md Abdullah Al; Furuta, Hiroshi; Hatta, Akimitsu

    2018-03-01

    The circuit design, assembly, and operating tests of a high-frequency and high-voltage (HV) pulsed dc generator (PDG) for capacitively coupled plasma (CCP) discharge inside a vacuum chamber are reported. For capacitive loads, it is challenging to obtain sharp rectangular pulses with fast rising and falling edges, requiring intense current for quick charging and discharging. The requirement of intense current generally limits the pulse operation frequency. In this study, we present a new type of PDG consisting of a pair of half-resonant converters and a constant current-controller circuit connected with HV solid-state power switches that can deliver almost rectangular high voltage pulses with fast rising and falling edges for CCP discharge. A prototype of the PDG is assembled to modulate from a high-voltage direct current (HVdc) input into a pulsed HVdc output, while following an input pulse signal and a set current level. The pulse rise time and fall time are less than 500 ns and 800 ns, respectively, and the minimum pulse width is 1 µs. The maximum voltage for a negative pulse is 1000 V, and the maximum repetition frequency is 500 kHz. During the pulse on time, the plasma discharge current is controlled steadily at the set value. The half-resonant converters in the PDG perform recovery of the remaining energy from the capacitive load at every termination of pulse discharge. The PDG performed with a high energy efficiency of 85% from the HVdc input to the pulsed dc output at a repetition rate of 1 kHz and with stable plasma operation in various discharge conditions. The results suggest that the developed PDG can be considered to be more efficient for plasma processing by CCP.

  15. 2D elemental mapping of sections of human kidney stones using laser ablation inductively-coupled plasma-mass spectrometry: Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Vašinová Galiová, Michaela [Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Central European Institute of Technology (CEITEC), Masaryk University, Kamenice 5, 625 00 Brno (Czech Republic); Čopjaková, Renata; Škoda, Radek [Department of Geological Sciences, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Štěpánková, Kateřina; Vaňková, Michaela [Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Kuta, Jan [Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Kamenice 126/3, 625 00 Brno (Czech Republic); Prokeš, Lubomír [Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno (Czech Republic); Kynický, Jindřich [Department of Pedology and Geology, Faculty of Forestry and Wood Technology, Mendel University in Brno, Zemědělská 3, 613 00 Brno (Czech Republic); and others

    2014-10-01

    A 213 nm Nd:YAG-based laser ablation (LA) system coupled to quadrupole-based inductively coupled plasma-mass spectrometer and an ArF* excimer-based LA-system coupled to a double-focusing sector field inductively coupled plasma-mass spectrometer were employed to study the spatial distribution of various elements in kidney stones (uroliths). Sections of the surfaces of uroliths were ablated according to line patterns to investigate the elemental profiles for the different urolith growth zones. This exploratory study was mainly focused on the distinguishing of the main constituents of urinary calculus fragments by means of LA-ICP-mass spectrometry. Changes in the ablation rate for oxalate and phosphate phases related to matrix density and hardness are discussed. Elemental association was investigated on the basis of 2D mapping. The possibility of using NIST SRM 1486 Bone Meal as an external standard for calibration was tested. It is shown that LA-ICP-MS is helpful for determination of the mineralogical composition and size of all phases within the analyzed surface area, for tracing down elemental associations and for documenting the elemental content of urinary stones. LA-ICP-MS results (elemental contents and maps) are compared to those obtained with electron microprobe analysis and solution analysis ICP-MS. - Highlights: • Elements in phosphate and oxalate urolith phases were quantified by LA-ICP-MS. • SRM NIST 1486 Bone Meal was proved suitable for quantification in uroliths. • Different ablation rates in particular phases were included at quantification. • Oxalate and apatite phases show opposite hardness order to natural minerals. • Uroliths were classified according to elemental association to phases.

  16. Polymerization by plasma of trichloroethylene by means of resistive and inductive coupling; Polimerizacion por plasmas de tricloroetileno por medio de acoplamiento resistivo e inductivo

    Energy Technology Data Exchange (ETDEWEB)

    Vasquez, M.; Cruz, G.; Olayo, M.G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Timoshina, T. [IPN, ESIQIE, 07738 Mexico D.F. (Mexico); Morales, J.; Olayo, R. [UAM-I, 09340 Mexico D.F. (Mexico)

    2004-07-01

    It was carried out the polymerization for plasma of the trichloroethylene by means of two types of coupling, resistive and inductive with the objective of studying the structure, morphology and the electric properties of the polymers obtained under these conditions. The structure and morphology of the polymers were studied by means of EDS and FT-IR spectroscopies. (Author)

  17. Developments and trends in inductively coupled plasma mass spectrometry and its influence on the recent advances in trace element analysis

    International Nuclear Information System (INIS)

    Balaram, V.

    1995-01-01

    A brief introduction to the various instrumental methods such as atomic absorption spectrometry, x-ray fluorescence spectrometry, neutron activation analysis, inductively coupled plasma atomic emission spectrometry, thermal ionization mass spectrometry, etc. are presented highlighting their relative merits and demerits. The history and developments of inductively coupled plasma mass spectrometry (ICP-MS) and its advantages and limitations over other multi-element instrumental techniques are reviewed. Extended capabilities by hyphenating ICP-MS to various other well-known sample introduction techniques such as flow-injection, electrothermal vaporization, chromatographic methods and laser ablation are discussed in brief. The recent development of high resolution multi-collector double-focusing magnetic mass spectrometer with inductively coupled plasma at atmospheric pressure as source is also discussed. Some of the areas where more developments can be expected in future are suggested. (author). 77 refs., 4 tabs., 3 figs

  18. Development and application of acousto-optic background correction for inductively coupled plasma atomic emission spectrometry.

    Science.gov (United States)

    Miller, Heather M; Spudich, Thomas M; Carnahan, Jon W

    2003-06-01

    In two configurations, a solid-state acousto-optic (AO) deflector or modulator is mounted in a 0.5 m monochromator for background correction with inductively coupled plasma atomic emission spectrometry (ICP-AES). A fused silica acousto-optic modulator (AOM) is used in the ultraviolet (UV) spectral region applications while a glass AO deflector (AOD) is used for the visible (VIS) region. The system provides rapid sequential observation of adjacent on- and off-line wavelengths for background correction. Seventeen elements are examined using pneumatic nebulization (PN) and electrothermal vaporization (ETV) sample introduction. Calibration plots were obtained with each sample introduction technique. Potable water and vitamin tablets were analyzed. Flame atomic absorption (FAA) was used to verify the accuracy of the AO background correction system.

  19. Capillary electrophoresis interfaced to inductively coupled plasma mass spectrometry for element selective detection in arsenic speciation.

    Science.gov (United States)

    Michalke, B; Schramel, P

    1998-09-01

    A method is presented to separate and detect six arsenic species by capillary electrophoresis (CE) interfaced to inductively coupled plasma mass spectrometry (ICP-MS). CE was used as a highly resolving separation system, whereas ICP-MS served as an element selective detector providing low detection limits. The special mode of operation included sample stacking and a differentiation of separation and detection. This provided separation and detection of six As species, uncharged and anionic, to be monitored within a single run. Detection limits were calculated according to IUPAC recommendation at 15 microg As/L for As (III), dimethyl arsinic acid (DA), monomethyl arsonic acid (MA) and As (V), or 65 microg As/L for arsenobetaine (AsB) and arsenocholine (AsC). Investigations were focused on possibly occurring interferences, e.g., ArCl+ interference at the monoisotope 75As. Finally, real samples from biomedical field (urine) and environmental field (sewage sludge) were analyzed.

  20. Determination of Rare Earth Elements in Thai Monazite by Inductively Coupled Plasma and Nuclear Analytical techniques

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Ratanapra, Dusadee; Sukharn, Sumalee; Laoharojanaphand, Sirinart

    2003-10-01

    The inductively coupled plasma atomic emission spectroscopy (ICP-AES) for the determination of individual rare-earth elements (REE) was evaluated by comparison with instrumental neutron activation analysis (INAA) and x-ray fluorescence spectrometry (XRF). The accuracy and precision of INAA and ICP-AES were evaluated by using standard reference material IGS-36, a monazite concentrate. For INAA, the results were close to the certified value while ICP-AES were in good agreement except for some low concentration rare earth. The techniques were applied for the analysis of some rare earth elements in two Thai monazite samples preparing as the in-house reference material for the Rare Earth Research and Development Center, Chemistry Division, Office of Atoms for Peace. The analytical results obtained by these techniques were in good agreement with each other

  1. Determination of elemental content off rocks by laser ablation inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Lichte, F.E.

    1995-01-01

    A new method of analysis for rocks and soils is presented using laser ablation inductively coupled plasma mass spectrometry. It is based on a lithium borate fusion and the free-running mode of a Nd/YAG laser. An Ar/N2 sample gas improves sensitivity 7 ?? for most elements. Sixty-three elements are characterized for the fusion, and 49 elements can be quantified. Internal standards and isotopic spikes ensure accurate results. Limits of detection are 0.01 ??g/g for many trace elements. Accuracy approaches 5% for all elements. A new quality assurance procedure is presented that uses fundamental parameters to test relative response factors for the calibration.

  2. Filterless preconcentration, flow injection analysis and detection by inductively-coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov

    The influence of interferences in the analysis of elements by inductively-coupled-plasma mass-spectrometry (ICP-MS) may be significantly diminished by utilising a protocol of flow-injection analysis (FIA). The method is based on filterless preconcentration of metallic elements at the walls...... of a knotted reactor that was made of nylon tubings. In the load mode, the preconcentration was accomplished by precipitation of metallic species in alkaline-buffered carriers onto the inner walls of the hydrofilic tube. After a preconcen-tration period of 40-120 seconds using sample volumes of 4-10 m...... of 10-30 were obtained in the analysis of aluminium, of chromium and of iron, which resulted in detection limits (3) down to 20 g/L at a sampling frequency of 50 per hour. The preconcentration protocol improves the selectivity thus allowing direct determination of the elements in saline media. Anionic...

  3. Standard practice for alternate actinide calibration for inductively coupled plasma-mass spectrometry

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This practice provides guidance for an alternate linear calibration for the determination of selected actinide isotopes in appropriately prepared aqueous solutions by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). This alternate calibration is mass bias adjusted using thorium-232 (232Th) and uranium-238 (238U) standards. One of the benefits of this standard practice is the ability to calibrate for the analysis of highly radioactive actinides using calibration standards at much lower specific activities. Environmental laboratories may find this standard practice useful if facilities are not available to handle the highly radioactive standards of the individual actinides of interest. 1.2 The instrument response for a series of determinations of known concentration of 232Th and 238U defines the mass versus response relationship. For each standard concentration, the slope of the line defined by 232Th and 238U is used to derive linear calibration curves for each mass of interest using interference equ...

  4. Laser ablation inductively coupled plasma mass spectrometry. An alternative technique for monitoring 90Sr

    International Nuclear Information System (INIS)

    TsingHai Wang; Yan-Chen Lai; Yi-Kong Hsieh; Chu-Fang Wang

    2017-01-01

    Developing a rapid detection method for monitoring released 90 Sr remains a challenge to analytical chemists, particularly considering its low concentration and significant interferences in environmental samples. We proposed a concept as an alternative to detect 90 Sr on the surface of fish scales using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The high affinity of fish scales to Sr is capable of preconcentrating 90 Sr that minimizes isobaric interferences from 90 Zr + or 89 YH + , while tailing effect by abundant 88 Sr can be effectively reduced by adjusting the forward power of ICP-MS component. Adopting dried droplets of internal standards further allows a semiquantification of 90 Sr content on the surface of fish scales, which also arises an opportunity to monitoring the bioaccumulation of 90 Sr after Fukushima Daiichi nuclear disaster. (author)

  5. Laser ablation microprobe inductively coupled plasma mass spectrometry study on diffusion of uranium into cement materials

    International Nuclear Information System (INIS)

    Sugiyama, D.; Chida, T.; Cowper, M.

    2008-01-01

    The diffusion of uranium (U(VI)) in solid cement monoliths of ordinary portland cement (OPC) and low-heat portland cement containing 30 wt.% fly ash (FAC) was measured by an in-diffusion technique. Detailed sharp depth profiles of uranium in the solid cement matrices were successively and quantitatively measured using laser ablation microprobe inductively coupled plasma mass spectrometry (LAMP-ICP-MS), and the apparent (D a ) and effective (D e ) diffusion coefficient of uranium in cement matrix were calculated as: D a =∝ 4 x 10 -16 m 2 s -1 and D e =∝ 3 x 10 -11 m 2 s -1 for OPC, and D a =∝ 2 x 10 -17 m 2 s -1 and D e =∝ 6 x 10 -13 m 2 s -1 for FAC. (orig.)

  6. Effect of Skimmer Cone Material on the Spectra of Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Amr, M.A.; Zahran, N.F.; Helal, A.I.

    2002-01-01

    The inductively coupled plasma ion source for mass spectrometry is very sensitive for multielement analysis with detection limits down to sub part per trillion (ppt). Polyatomic ions which could be formed in the mass spectra may interfere in the analysis of some element. Experimental conditions have great influences on the formation of polyatomic ions. The present work demonstrates that the skimmer materials (Au, Ag, Ni, and Cu) are participating in the formation of polyatomic ions, meanwhile the sampler materials have no real effect. The mechanism of formation of polyatomic ions is explained. Heats of formation of polyatomic species formed from the skimmer materials such as: Au X, Ag X, Ni X and Cu X; where X= Ar, O, N, C and H are calculated by Gaussian program (G 94 W)

  7. Observation of dust acoustic shock wave in a strongly coupled dusty plasma

    International Nuclear Information System (INIS)

    Sharma, Sumita K.; Boruah, A.; Nakamura, Y.; Bailung, H.

    2016-01-01

    Dust acoustic shock wave is observed in a strongly coupled laboratory dusty plasma. A supersonic flow of charged microparticles is allowed to perturb a stationary dust fluid to excite dust acoustic shock wave. The evolution process beginning with steepening of initial wave front and then formation of a stable shock structure is similar to the numerical results of the Korteweg-de Vries-Burgers equation. The measured Mach number of the observed shock wave agrees with the theoretical results. Reduction of shock amplitude at large distances is also observed due to the dust neutral collision and viscosity effects. The dispersion relation and the spatial damping of a linear dust acoustic wave are also measured and compared with the relevant theory.

  8. Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry (ICP-OES).

    Science.gov (United States)

    Gonzálvez, A; Armenta, S; De La Guardia, M

    2008-01-01

    A methodology based on inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion was developed to determine the content of traces elements in curry samples from the Spanish market. The methodology was validated in terms of accuracy by the analysis of citrus and tomato leaf reference materials achieving comparable results with the certified values. The trace metal content of curry samples was compared with data available from previously published reports concerning Indian samples, especially in terms of heavy metal composition, in order to guarantee the quality of the commercially available spices in the European countries. Values found for the analysis of arsenic, lead and cadmium were significantly lower than the maximum limit allowed by European Union statutory limits for heavy metals and lower than those obtained for Indian curry leaves reported by Indian research teams by using neutron activation and γ-ray analysis.

  9. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  10. Iodine Solid Source Inductively Coupled Plasma Etching of InP

    Science.gov (United States)

    Matsutani, Akihiro; Ohtsuki, Hideo; Koyama, Fumio

    2005-04-01

    We have demonstrated vertical and smooth inductively coupled plasma (ICP) dry etching of InP using solid iodine as a gas source at a low process temperature of 90°C. We prepared a solid iodine crystal in the ICP etching chamber as the etching gas source. Iodine gas was supplied from the solid source at a high vapor pressure into the process chamber. Vertical and smooth etching was realized under the condition of low temperature and low power. The typical etching rate was 0.4 μm/min. We believe that solid I2-ICP etching is a very simple and useful process for InP-based device fabrication with a resist mask.

  11. High-current electron beam coupling to hybrid waveguide and plasma modes in a dielectric Cherenkov maser with a plasma layer

    International Nuclear Information System (INIS)

    Shlapakovski, Anatoli S.

    2002-01-01

    The linear theory of a dielectric Cherenkov maser with a plasma layer has been developed. The dispersion relation has been derived for the model of infinitely thin, fully magnetized, monoenergetic hollow electron beam, in the axisymmetric case. The results of the numerical solution of the dispersion relation and the analysis of the beam coupling to hybrid waves, both hybrid waveguide and hybrid plasma modes, are presented. For the hybrid waveguide mode, spatial growth rate dependences on frequency at different plasma densities demonstrate improvement in gain for moderate densities, but strong shifting the amplification band and narrowing the bandwidth. For the hybrid plasma mode, the case of mildly relativistic, 200-250 keV beams is of interest, so that the wave phase velocity is just slightly greater than the speed of light in a dielectric medium. It has been shown that depending on beam and plasma parameters, the hybrid plasma mode can be separated from the hybrid waveguide mode, or be coupled to it through the beam resulting in strong gain increase, or exhibit a flat gain vs frequency dependence over a very broad band. The parameters, at which the -3 dB bandwidth calculated for 30 dB peak gain exceeds an octave, have been found

  12. Self-consistent multidimensional electron kinetic model for inductively coupled plasma sources

    Science.gov (United States)

    Dai, Fa Foster

    Inductively coupled plasma (ICP) sources have received increasing interest in microelectronics fabrication and lighting industry. In 2-D configuration space (r, z) and 2-D velocity domain (νθ,νz), a self- consistent electron kinetic analytic model is developed for various ICP sources. The electromagnetic (EM) model is established based on modal analysis, while the kinetic analysis gives the perturbed Maxwellian distribution of electrons by solving Boltzmann-Vlasov equation. The self- consistent algorithm combines the EM model and the kinetic analysis by updating their results consistently until the solution converges. The closed-form solutions in the analytical model provide rigorous and fast computing for the EM fields and the electron kinetic behavior. The kinetic analysis shows that the RF energy in an ICP source is extracted by a collisionless dissipation mechanism, if the electron thermovelocity is close to the RF phase velocities. A criterion for collisionless damping is thus given based on the analytic solutions. To achieve uniformly distributed plasma for plasma processing, we propose a novel discharge structure with both planar and vertical coil excitations. The theoretical results demonstrate improved uniformity for the excited azimuthal E-field in the chamber. Non-monotonic spatial decay in electric field and space current distributions was recently observed in weakly- collisional plasmas. The anomalous skin effect is found to be responsible for this phenomenon. The proposed model successfully models the non-monotonic spatial decay effect and achieves good agreements with the measurements for different applied RF powers. The proposed analytical model is compared with other theoretical models and different experimental measurements. The developed model is also applied to two kinds of ICP discharges used for electrodeless light sources. One structure uses a vertical internal coil antenna to excite plasmas and another has a metal shield to prevent the

  13. Consequences of atomic layer etching on wafer scale uniformity in inductively coupled plasmas

    Science.gov (United States)

    Huard, Chad M.; Lanham, Steven J.; Kushner, Mark J.

    2018-04-01

    Atomic layer etching (ALE) typically divides the etching process into two self-limited reactions. One reaction passivates a single layer of material while the second preferentially removes the passivated layer. As such, under ideal conditions the wafer scale uniformity of ALE should be independent of the uniformity of the reactant fluxes onto the wafers, provided all surface reactions are saturated. The passivation and etch steps should individually asymptotically saturate after a characteristic fluence of reactants has been delivered to each site. In this paper, results from a computational investigation are discussed regarding the uniformity of ALE of Si in Cl2 containing inductively coupled plasmas when the reactant fluxes are both non-uniform and non-ideal. In the parameter space investigated for inductively coupled plasmas, the local etch rate for continuous processing was proportional to the ion flux. When operated with saturated conditions (that is, both ALE steps are allowed to self-terminate), the ALE process is less sensitive to non-uniformities in the incoming ion flux than continuous etching. Operating ALE in a sub-saturation regime resulted in less uniform etching. It was also found that ALE processing with saturated steps requires a larger total ion fluence than continuous etching to achieve the same etch depth. This condition may result in increased resist erosion and/or damage to stopping layers using ALE. While these results demonstrate that ALE provides increased etch depth uniformity, they do not show an improved critical dimension uniformity in all cases. These possible limitations to ALE processing, as well as increased processing time, will be part of the process optimization that includes the benefits of atomic resolution and improved uniformity.

  14. Analysis of non-equilibrium phenomena in inductively coupled plasma generators

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, W.; Panesi, M., E-mail: mpanesi@illinois.edu [University of Illinois at Urbana-Champaign, Urbana, Illinois 61822 (United States); Lani, A. [Von Karman Institute for Fluid Dynamics, Rhode-Saint-Genèse (Belgium)

    2016-07-15

    This work addresses the modeling of non-equilibrium phenomena in inductively coupled plasma discharges. In the proposed computational model, the electromagnetic induction equation is solved together with the set of Navier-Stokes equations in order to compute the electromagnetic and flow fields, accounting for their mutual interaction. Semi-classical statistical thermodynamics is used to determine the plasma thermodynamic properties, while transport properties are obtained from kinetic principles, with the method of Chapman and Enskog. Particle ambipolar diffusive fluxes are found by solving the Stefan-Maxwell equations with a simple iterative method. Two physico-mathematical formulations are used to model the chemical reaction processes: (1) A Local Thermodynamics Equilibrium (LTE) formulation and (2) a thermo-chemical non-equilibrium (TCNEQ) formulation. In the TCNEQ model, thermal non-equilibrium between the translational energy mode of the gas and the vibrational energy mode of individual molecules is accounted for. The electronic states of the chemical species are assumed in equilibrium with the vibrational temperature, whereas the rotational energy mode is assumed to be equilibrated with translation. Three different physical models are used to account for the coupling of chemistry and energy transfer processes. Numerical simulations obtained with the LTE and TCNEQ formulations are used to characterize the extent of non-equilibrium of the flow inside the Plasmatron facility at the von Karman Institute. Each model was tested using different kinetic mechanisms to assess the sensitivity of the results to variations in the reaction parameters. A comparison of temperatures and composition profiles at the outlet of the torch demonstrates that the flow is in non-equilibrium for operating conditions characterized by pressures below 30 000 Pa, frequency 0.37 MHz, input power 80 kW, and mass flow 8 g/s.

  15. Atlas of Atomic Spectral Lines of Neptunium Emitted by Inductively Coupled Plasma

    Energy Technology Data Exchange (ETDEWEB)

    DeKalb, E.L. and Edelson, M. C.

    1987-08-01

    Optical emission spectra from high-purity Np-237 were generated with a glovebox-enclosed inductively coupled plasma (ICP) source. Spectra covering the 230-700 nm wavelength range are presented along with general commentary on the methodology used in collecting the data. The Ames Laboratory Nuclear Safeguards and Security Program has been charged with the task of developing optical spectroscopic methods to analyze the composition of spent nuclear fuels. Such materials are highly radioactive even after prolonged 'cooling' and are chemically complex. Neptunium (Np) is a highly toxic by-product of nuclear power generation and is found, in low abundance, in spent nuclear fuels. This atlas of the optical emission spectrum of Np, as produced by an inductively coupled plasma (ICP) spectroscopic source, is part of a general survey of the ICP emission spectra of the actinide elements. The ICP emission spectrum of the actinides originates almost exclusively from the electronic relaxation of excited, singly ionized species. Spectral data on the Np ion emission spectrum (i.e., the Np II spectrum) have been reported by Tomkins and Fred [1] and Haaland [2]. Tomkins and Fred excited the Np II spectrum with a Cu spark discharge and identified 114 Np lines in the 265.5 - 436.3 nm spectral range. Haaland, who corrected some spectral line misidentifications in the work of Tomkins and Fred, utilized an enclosed Au spark discharge to excite the Np II spectrum and reported 203 Np lines within the 265.4 - 461.0 nm wavelength range.

  16. Atlas of Atomic Spectral Lines of Neptunium Emitted by an Inductively Coupled Plasma

    International Nuclear Information System (INIS)

    DeKalb, E.L.; Edelson, M.C.

    1987-01-01

    Optical emission spectra from high-purity Np-237 were generated with a glovebox-enclosed inductively coupled plasma (ICP) source. Spectra covering the 230-700 nm wavelength range are presented along with general commentary on the methodology used in collecting the data. The Ames Laboratory Nuclear Safeguards and Security Program has been charged with the task of developing optical spectroscopic methods to analyze the composition of spent nuclear fuels. Such materials are highly radioactive even after prolonged 'cooling' and are chemically complex. Neptunium (Np) is a highly toxic by-product of nuclear power generation and is found, in low abundance, in spent nuclear fuels. This atlas of the optical emission spectrum of Np, as produced by an inductively coupled plasma (ICP) spectroscopic source, is part of a general survey of the ICP emission spectra of the actinide elements. The ICP emission spectrum of the actinides originates almost exclusively from the electronic relaxation of excited, singly ionized species. Spectral data on the Np ion emission spectrum (i.e., the Np II spectrum) have been reported by Tomkins and Fred (1) and Haaland (2). Tomkins and Fred excited the Np II spectrum with a Cu spark discharge and identified 114 Np lines in the 265.5 - 436.3 nm spectral range. Haaland, who corrected some spectral line misidentifications in the work of Tomkins and Fred, utilized an enclosed Au spark discharge to excite the Np II spectrum and reported 203 Np lines within the 265.4 - 461.0 nm wavelength range.

  17. An effect of the fringing field in sector bending magnets: the coupling of the transverse planes in the solutions of the equation of motion at second-order

    International Nuclear Information System (INIS)

    Roy, G.

    1988-11-01

    Second order coupling terms for sector bending magnets due to edge effects at high energy are reviewed. Motion in the horizontal plane (bending plane) and in the vertical (nonbending) plane is considered. The model of Heaviside's function is outlined. The case of the complete bending magnet is treated. Three second order coupling terms between the vertical and horizontal planes in a complete bending magnet are found. Their origin is the fringing field, i.e., the intensity difference of the magnetic field between the outside and the inside of the magnet

  18. Characteristics of X-Ray Emission from the PFRC-2 Capacitively Coupled Plasma

    Science.gov (United States)

    Oliver, Richard; Pearcy, Jacob; Jandovitz, Peter; Swanson, Charles; Matteucci, Jackson; Cohen, Samuel; PFRC Team

    2015-11-01

    It is uncertain what causes keV X-rays emitted from the central-cell region of a cool (bulk Te ~ 4 eV), tenuous (ne ~1010 cm-3), 5 cm diameter, weakly ionized hydrogen plasma column generated in a tandem high-mirror-ratio mirror machine (PFRC-2 device) by a low-power, external, capacitively-coupled RF (27 MHz) antenna. We explored whether the energetic electrons responsible for the X-rays exist only in the central cell (ER) or also in the asymmetric mirror regions at opposite ends of the machine, as well as how the spectra compare if they do exist in both regions. To address this, we have designed, built, calibrated, installed and operated an X-ray detector system to view the PFRC-2 region near the RF antenna in one end cell (MC). We observe somewhat different X-ray spectra emanating from the two regions. The system comprises two Amptek XR-100CR detectors with moveable slits that scan across the plasma column. Further control of radial resolution (to 0.4 cm) is afforded by changing the detector-to-slit distance. Calibrations were performed with an 55Fe source. These data are being used to understand the source of the fast electrons that create the X-rays in the MC and in the ER. This work is supported by the US DOE Contract No. DE-AC02-09CH11466 and the Princeton Environmental Institute.

  19. Unique applications of solvent removal in inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Minnich, Michael [Iowa State Univ., Ames, IA (United States)

    1997-01-10

    Inductively coupled plasma mass spectrometry (ICP-MS) is the technique of choice for rapid, high precision, semiquantitative elemental and isotopic analysis for over 70 elements. Less than 20 years after the first mass spectrum was obtained by ICP-MS, this technique has applications in clinical chemistry, geochemistry, the semiconductor industry, the nuclear industry, environmental chemistry, and forensic chemistry. The determination of many elements, though, by ICP-MS is complicated by spectral interferences from background species, interelement spectral overlaps, and polyatomic ions of matrix elements. The emphasis of this thesis is the unique applications of solvent removal using cryogenic and membrane desolvation. Chapter 1 is a general introduction providing background information concerning the need for these methods and some information about the methods themselves. Chapter 5 discusses general conclusions and general observations pertaining to this work. Chapters 2, 3, and 4 have been processed separately for inclusion on the database. Chapter 2 describes a method to screen urine samples for vanadium using cryogenic desolvation. Chapter 3 compares solvent removal by cryogenic and membrane desolvation. Chapter 4 describes the use of cool plasma conditions for the determination of potassium in the presence of excess sodium by ICP-MS.

  20. Generating high-efficiency neutral beams by using negative ions in an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Samukawa, Seiji; Sakamoto, Keisuke; Ichiki, Katsunori

    2002-01-01

    To minimize radiation damage caused by charge buildup or ultraviolet and x-ray photons during etching, we developed a high-performance neutral-beam etching system. The neutral-beam source consists of an inductively coupled plasma (ICP) source and parallel top and bottom carbon plates. The bottom carbon plate has numerous apertures for extracting neutral beams from the plasma. When a direct current (dc) bias is applied to the top and bottom plates, the generated positive or negative ions are accelerated toward the bottom plate. Most of them are then efficiently converted into neutral atoms, either by neutralization in charge-transfer collisions with gas molecules during ion transport and with the aperture sidewalls in the bottom plate, or by recombination with low-energy electrons near the end of the bottom plate. We found that negative ions are more efficiently converted into neutral atoms than positive ions. The neutralization efficiency of negative ions was almost 100%, and the maximum neutral flux density was equivalent to 4.0 mA/cm2. A neutral beam can thus be efficiently produced from the ICP source and apertures in our new neutral-beam source

  1. Study of electron-extraction characteristics of an inductively coupled radio-frequency plasma neutralizer

    Science.gov (United States)

    Jianwu, HE; Longfei, MA; Senwen, XUE; Chu, ZHANG; Li, DUAN; Qi, KANG

    2018-01-01

    Inductively coupled radio-frequency (RF) plasma neutralizer (RPN) is an insert-free device that can be employed as an electron source in electric propulsion applications. Electron-extraction characteristics of the RPN are related to the bulk plasma parameters and the device’s geometry. Therefore, the effects of different electron-extraction apertures and operational parameters upon the electron-extraction characteristics are investigated according to the global nonambipolar flow and sheath model. Moreover, these models can also be used to explain why the electron-extraction characteristics of the RPN strongly depend upon the formation of the anode spot. During the experimental study, two types of anode spots are observed. Each of them has unique characteristics of electron extraction. Moreover, the hysteresis of an anode spot is observed by changing the xenon volume-flow rates or the bias voltages. In addition, the rapid ignited method, gas-utilization factor, electron-extraction cost and other factors that need to be considered in the design of the RPN are also discussed.

  2. Some Temperature Effects on AISI-304 Nitriding in an Inductively Coupled RF Plasma

    International Nuclear Information System (INIS)

    Valencia-Alvarado, R.; Barocio, S. R.; Mercado-Cabrera, A.; Pena-Eguiluz, R.; Munoz-Castro, A. E.; Piedad-Beneitez, A. de la; Rosa-Vazquez, J. de la; Lopez-Callejas, R.; Godoy-Cabrera, O. G.

    2006-01-01

    Some recent results obtained from nitriding AISI 304 stainless steel samples, 1.2 cm in diameter and 0.5 cm thick are reported here in the case of an 85% hydrogen and 15% nitrogen mixture work gas. The process was carried out from 300 to 400 W for (13.56 MHz) inductively coupled plasma within a 60 cm long pyrex glass tube 3.5 cm in diameter where the samples were biased up to -300 V with respect to earth. The resulting hardness appears to be a function of the substrate temperature which varied from 200 deg. C at a 0 V bias to 550 deg. C at -300 V. The plasma density at 400 W reached 3x1010 cm-3 with a 4 eV electron temperature. Prior to nitriding, all the samples were polished with 0.05 μm diamond paste, leading to a 30 nm average roughness (Ra). After nitriding at -300 V, the Ra rose until ∼400 nm while hardness values of 1500 HV under 300 g loads were measured. X ray diffraction indicates that the extended phase amplitude (γN), Fe and Cr nitride depends on the substrate temperature

  3. Thin TiO2 films deposited by implantation and sputtering in RF inductively coupled plasmas

    International Nuclear Information System (INIS)

    Valencia-Alvarado, R; López-Callejas, R; Barocio, S R; Mercado-Cabrera, A; Peña-Eguiluz, R; Muñoz-Castro, A E; Rodríguez-Méndez, B G; De la Piedad-Beneitez, A; De la Rosa-Vázquez, J M

    2012-01-01

    The achievement of titanium dioxide (TiO 2 ) thin films in the rutile crystalline phase is reported. The samples result from the implantation of oxygen ions of Ti in argon/oxygen plasma generated by inductively coupled RF at a commercial 13.56 MHz frequency. Simultaneously, a sputtering process is conducted on the titanium target in order to produce TiO 2 thin films in the anatase phase over silicon and glass substrates. Both implantation and sputtering processes shared the same 500 W plasma with the target, polarized between 0 and -3 kV. The substrates were placed between 2 and 3 cm from the target, this distance being found to be determinant of the TiO 2 deposition rate. The rutile phase in the target was obtained at temperatures in the order of 680 degrees C and the anatase (unbiased) one at about 300 degrees C without any auxiliary heating. The crystalline phases were characterized by x ray diffraction and Raman spectroscopy. The morphology and average roughness were established by means of scanning electronic and atomic force microscopy, whereas the reaction products generated during the oxidation process were analyzed by mass spectrometry. Finally, the stoichiometric composition was measured by means of X-ray photoelectron spectroscopy.

  4. Neutral Gas Temperature Estimates in an Inductively Coupled CF4 Plasma by Fitting Diatomic Emission Spectra

    Science.gov (United States)

    Cruden, Brett A.; Rao, M. V. V. S.; Sharma, Surendra P.; Meyyappan, M.

    2001-01-01

    This work examines the accuracy of plasma neutral temperature estimates by fitting the rotational band envelope of different diatomic species in emission. Experiments are performed in an inductively coupled CF4 plasma generated in a Gaseous Electronics Conference reference cell. Visible and ultraviolet emission spectra are collected at a power of 300 W (approximately 0.7 W/cc) and pressure of 30 mtorr. The emission bands of several molecules (CF, CN, C2, CO, and SiF) are fit simultaneously for rotational and vibrational temperatures and compared. Four different rotational temperatures are obtained: 1250 K for CF and CN, 1600 K for CO, 1800 K for C2, and 2300 K for SiF. The vibrational temperatures obtained vary from 1750-5950 K, with the higher vibrational temperatures generally corresponding to the lower rotational temperatures. These results suggest that the different species have achieved different degrees of equilibration between the rotational and vibrational modes and may not be equilibrated with the translational temperatures. The different temperatures are also related to the likelihood that the species are produced by ion bombardment of the surface, with etch products like SiF, CO, and C2 having higher temperatures than species expected to have formed in the gas phase.

  5. Recycling nebulization-sample introduction system for inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Kato, Kaneharu; Takashima, Kyoichiro

    1989-01-01

    A recycling nebulization-sample introduction system which exhibits the long-term stability of analyte emission signals while consuming small sample volumes was constructed for inductively coupled plasma atomic emission spectrometry. The present system is composed of five main parts: i.e., a spherical cyclone spray chamber, two commercial concentric nebulizers, two 3-way stopcocks, an aerosol transport tube with heater, and a commercial concentric three-tube plasma torch. It is based on the spray chamber where the two nebulizers are mounted (twin-nebulizer configuration): one is for introduction of a sample or a rinse solution into the spray chamber, and the other one is for recycling nebulization of the solution introduced. The nebulizers are easily demountable symmetrically and horizontally outside the spray chamber. Analytical performance and nebulization characteristics are described in comparison with a conventional sample introduction system. A stable signal of analyte emission intensity was extended to 20 min for 1 ml of sample under the ordinary condition of 0.6l/min carrier gas flow rate. (author)

  6. Unexpected properties of the inductively coupled plasma induced defect in germanium

    Energy Technology Data Exchange (ETDEWEB)

    Coelho, S.M.M., E-mail: sergio@up.ac.za; Auret, F.D.; Janse van Rensburg, P.J.; Nel, J.M.

    2014-04-15

    Inductively coupled plasma (ICP) etching of germanium introduces a single defect, the E{sub 0.31} electron trap, for a large range of argon partial pressures from 4×10{sup –3} to 6.5×10{sup –4} mbar that correspond to ion energies of 8 to 60 eV. Ge of three crystallographic orientations, (1 0 0), (1 1 0) and (1 1 1), treated with 20 and 60 eV ICP had defect concentration profiles that were similar in appearance, with a maximum concentration of 10{sup 14} cm{sup −3} extending more than a µm into the material, approximately three orders of magnitude deeper than what TRIM simulations predicted. All profiles were measured using Laplace deep level transient spectroscopy (L-DLTS), a technique that is sensitive to defect concentrations as low as 10{sup 11} cm{sup −3}. Isochronal annealing of samples showed concentration curves broadening after a 400 K anneal and decreasing to the 10{sup 13} cm{sup −3} level after a 450 K anneal. Unannealed samples measured after a year exhibited similar decreases in defect concentration without broadening of their profiles. A 550 K anneal lowered the defect concentration to levels below the L-DLTS detection limit. Thereafter additional plasma treatment of the surface failed to reintroduce this defect indicating that the structure required for the formation of E{sub 0.31} was no longer present in the region under observation.

  7. Ion Clouds in the Inductively Coupled Plasma Torch: A Closer Look through Computations.

    Science.gov (United States)

    Aghaei, Maryam; Lindner, Helmut; Bogaerts, Annemie

    2016-08-16

    We have computationally investigated the introduction of copper elemental particles in an inductively coupled plasma torch connected to a sampling cone, including for the first time the ionization of the sample. The sample is inserted as liquid particles, which are followed inside the entire torch, i.e., from the injector inlet up to the ionization and reaching the sampler. The spatial position of the ion clouds inside the torch as well as detailed information on the copper species fluxes at the position of the sampler orifice and the exhausts of the torch are provided. The effect of on- and off-axis injection is studied. We clearly show that the ion clouds of on-axis injected material are located closer to the sampler with less radial diffusion. This guarantees a higher transport efficiency through the sampler cone. Moreover, our model reveals the optimum ranges of applied power and flow rates, which ensure the proper position of ion clouds inside the torch, i.e., close enough to the sampler to increase the fraction that can enter the mass spectrometer and with minimum loss of material toward the exhausts as well as a sufficiently high plasma temperature for efficient ionization.

  8. Environmental samples analysis by Atomic Absorption Spectrophotometry and Inductively Coupled Plasma-Optical Emission Spectroscopy

    International Nuclear Information System (INIS)

    Popescu, I.V.; Iordan, M.; Stihi, C.; Bancuta, A.; Busuioc, G.; Dima, G.; Ciupina, V.; Belc, M.; Vlaicu, Gh.; Marian, R.

    2002-01-01

    Biological samples are interesting from many aspects of environmental monitoring. By analyzing tree leaves conclusions can be drown regarding the metal loading in the growth medium. So that, starting from assumption that the pollution factors from environmental medium can modify the normal concentration of elements, we decided to control the presence of toxic elements and the deviation from normal state of elements in leaves of different trees from areas situated at different distances of pollution source. The aim of this work is to determine the elemental composition of tree leaves using Atomic Absorption Spectrophotometry (AAS) method and Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) method. Using AAS spectrophotometer SHIMADZU we identified and determined the concentration of: Cd, Co, Cu, Zn, Mn, Cr, Fe, Se, Pb with an instrumental error less than 1% for most of the elements analyzed. The same samples were analyzed by ICP-OES spectrometer, BAIRD ICP2070-Sequential Plasma spectrometer. We identified and determined in leaves of different trees the concentration of Mg, Ca, and Sr with a precision less than 6%. (authors)

  9. Analytical performance of an inductively coupled plasma optical emission spectrometry with Dual View configuration

    Directory of Open Access Journals (Sweden)

    Silva Júlio C. J.

    2003-01-01

    Full Text Available The analytical performance of axially and radially viewed inductively coupled plasma optical emission spectrometers (AX-ICP OES and RD-ICP OES, respectively were evaluated in terms of the Mg II/Mg I ratio, matrix effects, and detection limits (LOD. All solutions were made in either 1% v v-1 nitric acid or in a 10% v v-1 water-soluble tertiary amine solution (CFA-C adjusted to pH 8. Using a nebulization gas flow-rate of 0.5 L min-1 and applied power of 1.3 kW, Mg II/Mg I ratio was at least 15 in any medium for both configurations. Under robust conditions, plasma processes were practically not affected by the presence of 0.1% m v-1 of Ca, K, or Na in both configurations. However, interference effects were observed with non-robust conditions, mainly with AX-ICP OES in both media. The best detection limits were obtained using AX-ICP OES under robust conditions, with solutions prepared in the amine medium.

  10. Inductively coupled plasma induced deep levels in epitaxial n-GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Auret, F.D.; Janse van Rensburg, P.J.; Meyer, W.E.; Coelho, S.M.M. [Department of Physics, University of the Pretoria, Lynnwood Road, Pretoria 0002 (South Africa); Kolkovsky, Vl. [Technische Universitaet, Dresden, 01062 Dresden (Germany); Botha, J.R.; Nyamhere, C. [Department of Physics, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa); Venter, A., E-mail: andre.venter@nmmu.ac.za [Department of Physics, Nelson Mandela Metropolitan University, PO Box 77000, Port Elizabeth 6031 (South Africa)

    2012-05-15

    The electronic properties of defects introduced by low energy inductively coupled Ar plasma etching of n-type (Si doped) GaAs were investigated by deep level transient spectroscopy (DLTS) and Laplace DLTS. Several prominent electron traps (E{sub c}-0.046 eV, E{sub c}-0.186 eV, E{sub c}-0.314 eV. E{sub c}-0.528 eV and E{sub c}-0.605 eV) were detected. The metastable defect E{sub c}-0.046 eV having a trap signature similar to E1 is observed for the first time. E{sub c}-0.314 eV and E{sub c}-0.605 eV are metastable and appear to be similar to the M3 and M4 defects present in dc H-plasma exposed GaAs.

  11. Fabrication of SiC nanopillars by inductively coupled SF6/O2 plasma etching

    Science.gov (United States)

    Choi, J. H.; Latu-Romain, L.; Bano, E.; Dhalluin, F.; Chevolleau, T.; Baron, T.

    2012-06-01

    In this paper, we demonstrate a top-down fabrication technique for nanometre scale silicon carbide (SiC) pillars using inductively coupled plasma etching. A set of experiments in SF6-based plasma was carried out in order to realize high aspect ratio SiC nanopillars. The etched SiC nanopillars using a small circular mask pattern (115 nm diameter) show high aspect ratio (7.4) with a height of 2.2 µm at an optimum bias voltage (300 V) and pressure (6 mTorr). Under the optimal etching conditions using a large circular mask pattern with 370 nm diameter, the obtained SiC nanopillars exhibit high anisotropy features (6.4) with a large etch depth (>7 µm). The etch characteristic of the SiC nanopillars under these conditions shows a high etch rate (550 nm min-1) and a high selectivity (over 60 for Ni). We also studied the etch profile of the SiC nanopillars and mask evolution over the etching time. As the mask pattern size shrinks in nanoscale, vertical and lateral mask erosion plays a crucial role in the etch profile of the SiC nanopillars. Long etching process makes the pillars appear with a hexagonal shape, coming from the crystallographic structure of α-SiC. It is found that the feature of pillars depends not only on the etching process parameters, but also on the crystallographic structure of the SiC phase.

  12. Sheared magnetospheric plasma flows and discrete auroral arcs: a quasi-static coupling model

    Directory of Open Access Journals (Sweden)

    M. M. Echim

    2007-02-01

    Full Text Available We consider sheared flows in magnetospheric boundary layers of tangential discontinuity type, forming a structure that is embedded in a large-scale convergent perpendicular electric field. We construct a kinetic model that couples the magnetospheric structure with the topside ionosphere. The contribution of magnetospheric electrons and ionospheric electrons and ions is taken into account into the current-voltage relationship derived for an electric potential monotonically decreasing with the altitude. The solution of the current continuity equation gives the distribution of the ionospheric potential consistent with the given magnetospheric electric potential. The model shows that a sheared magnetospheric flow generates current sheets corresponding to upward field-aligned currents, field-aligned potential drops and narrow bands of precipitating energy, as in discrete auroral arcs. Higher velocity magnetospheric sheared flows have the tendency to produce brighter and slightly broader arcs. An increase in arc luminosity is also associated with enhancements of magnetospheric plasma density, in which case the structures are narrower. Finally, the model predicts that an increase of the electron temperature of the magnetospheric flowing plasma corresponds to slightly wider arcs but does not modify their luminosity.

  13. Collisionless coupling of a high- β expansion to an ambient, magnetized plasma. I. Rayleigh model and scaling

    Science.gov (United States)

    Bonde, Jeffrey

    2018-04-01

    The dynamics of a magnetized, expanding plasma with a high ratio of kinetic energy density to ambient magnetic field energy density, or β, are examined by adapting a model of gaseous bubbles expanding in liquids as developed by Lord Rayleigh. New features include scale magnitudes and evolution of the electric fields in the system. The collisionless coupling between the expanding and ambient plasma due to these fields is described as well as the relevant scaling relations. Several different responses of the ambient plasma to the expansion are identified in this model, and for most laboratory experiments, ambient ions should be pulled inward, against the expansion due to the dominance of the electrostatic field.

  14. Influence of heat and particle fluxes nonlocality on spatial distribution of plasma density in two-chamber inductively coupled plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Kudryavtsev, A. A.; Serditov, K. Yu. [Faculty of Physics, St. Petersburg State University, 198504 St. Petersburg (Russian Federation)

    2012-07-15

    This study presents 2D simulations of the two-chamber inductively coupled plasma source where power is supplied in the small discharge chamber and extends by electron thermal conductivity mechanism to the big diffusion chamber. Depending on pressure, two main scenarios of plasma density and its spatial distribution behavior were identified. One case is characterized by the localization of plasma in the small driver chamber where power is deposed. Another case describes when the diffusion chamber becomes the main source of plasma with maximum of the electron density. The differences in spatial distribution are caused by local or non-local behavior of electron energy transport in the discharge volume due to different characteristic scale of heat transfer with electronic conductivity.

  15. Superfluid plasmas: Multivelocity nonlinear hydrodynamics of superfluid solutions with charged condensates coupled electromagnetically

    International Nuclear Information System (INIS)

    Holm, D.D.; Kupershmidt, B.A.

    1987-01-01

    Four levels of nonlinear hydrodynamic description are presented for a nondissipative multicondensate solution of superfluids with vorticity. First, the multivelocity superfluid (MVSF) theory is extended to the case of a multivelocity superfluid plasma (MVSP), in which some of the superfluid condensates (protons, say) are charged and coupled electromagnetically to an additional, normal, charged fluid (electrons). The resulting drag-current density is derived due to the electromagnetic coupling of the condensates with the normal fluids. For the case of one charged condensate, the MVSP equations simplify to what we call superfluid Hall magnetohydrodynamics (SHMHD) in the approximation that displacement current and electron inertia are negligible, and local charge neutrality is imposed. The contribution of the charged condensate to the Hall drift force is determined. In turn, neglecting the Hall effect in SHMHD gives the equations of superfluid magnetohydrodynamics (SMHD). Each set of equations (MVSF, MVSP, SHMHD, and SMHD) is shown to be Hamiltonian and to possess a Poisson bracket associated with the dual space of a corresponding semidirect-product Lie algebra with a generalized two-cocycle defined on it. Topological conservation laws (helicities) associated with the kernels of these Lie algebras are also discussed as well as those associated physically with generalized Kelvin theorems for conservation of superfluid circulation around closed loops moving with the normal fluid

  16. The effect of SF6 addition in a Cl2/Ar inductively coupled plasma for deep titanium etching

    Science.gov (United States)

    Laudrel, E.; Tillocher, T.; Meric, Y.; Lefaucheux, P.; Boutaud, B.; Dussart, R.

    2018-05-01

    Titanium is a material of interest for the biomedical field and more particularly for body implantable devices. Titanium deep etching by plasma was carried out in an inductively coupled plasma with a chlorine-based chemistry for the fabrication of titanium-based microdevices. Bulk titanium etch rate was first studied in Cl2/Ar plasma mixture versus the source power and the self-bias voltage. The plasma was characterized by Langmuir probe and by optical emission spectroscopy. The addition of SF6 in the plasma mixture was investigated. Titanium etch rate was optimized and reached a value of 2.4 µm · min-1. The nickel hard mask selectivity was also enhanced. The etched titanium surface roughness was reduced significantly.

  17. Electrical properties of ultra-thin oxynitrided layer using N2O plasma in inductively coupled plasma chemical vapor deposition for non-volatile memory on glass

    International Nuclear Information System (INIS)

    Jung, Sungwook; Hwang, Sunghyun; Kim, Kyunghae; Dhungel, S.K.; Chung, Ho-Kyoon; Choi, Byoung-Deog; Lee, Ki-Yong; Yi, J.

    2007-01-01

    In this work, the silicon oxynitride layer was studied as a tunneling layer for non-volatile memory application by fabricating low temperature polysilicon thin film transistors on glass. Silicon wafers were oxynitrided by only nitrous oxide plasma under different radio frequency powers and plasma treatment times. Plasma oxynitridation was performed in RF plasma using inductively coupled plasma chemical vapor deposition. The X-ray energy dispersive spectroscopy was employed to analyze the atomic concentration ratio of nitrogen/oxygen in oxynitride layer. The oxynitrided layer formed under radio frequency power of 150 W and substrate temperature of 623 K was found to contain the atomic concentration ratio of nitrogen/oxygen as high as 1.57. The advantage of high nitrogen concentration in silicon oxide layer formed by using nitrous oxide plasma was investigated by capacitance-voltage measurement. The analysis of capacitance-voltage characteristics demonstrated that the ultra-thin oxynitride layers of 2 nm thickness formed by only nitrous oxide plasma have good properties as tunneling layer for non-volatile memory device

  18. Electromagnetic wave energy flow control with a tunable and reconfigurable coupled plasma split-ring resonator metamaterial: A study of basic conditions and configurations

    Energy Technology Data Exchange (ETDEWEB)

    Kourtzanidis, Konstantinos, E-mail: kkourt@utexas.edu; Pederson, Dylan M.; Raja, Laxminarayan L. [Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712-1221 (United States)

    2016-05-28

    We propose and study numerically a tunable and reconfigurable metamaterial based on coupled split-ring resonators (SRRs) and plasma discharges. The metamaterial couples the magnetic-electric response of the SRR structure with the electric response of a controllable plasma slab discharge that occupies a volume of the metamaterial. Because the electric response of a plasma depends on its constitutive parameters (electron density and collision frequency), the plasma-based metamaterial is tunable and active. Using three-dimensional numerical simulations, we analyze the coupled plasma-SRR metamaterial in terms of transmittance, performing parametric studies on the effects of electron density, collisional frequency, and the position of the plasma slab with respect to the SRR array. We find that the resonance frequency can be controlled by the plasma position or the plasma-to-collision frequency ratio, while transmittance is highly dependent on the latter.

  19. Phase-space-Lagrangian action principle and the generalized K-X theorem. [in covariant coupled equations for plasma dynamics

    Science.gov (United States)

    Kaufman, Allan N.

    1987-01-01

    The covariant coupled equations for plasma dynamics and the Maxwell field are expressed as a phase-space-Lagrangian action principle. The linear interaction is transformed to the bilinear beat Hamiltonian by a gauge-invariant Lagrangian Lie transform. The result yields the generalized linear susceptibility directly.

  20. Determination of platinum surface contamination in veterinary and human oncology centres using inductively coupled plasma mass spectrometry

    NARCIS (Netherlands)

    Janssens, T.; Brouwers, E. E M; de Vos, J. P.; de Vries, N.; Schellens, J. H M; Beijnen, J. H.

    2015-01-01

    The objective of this study was to determine the surface contamination with platinum-containing antineoplastic drugs in veterinary and human oncology centres. Inductively coupled plasma mass spectrometry was used to measure platinum levels in surface samples. In veterinary and human oncology

  1. High density plasma etching of ultrananocrystalline diamond films in O2/CF4 and O2/SF6 inductively coupled plasmas

    Science.gov (United States)

    Park, Jong Cheon; Kim, Seong Hak; Kim, Tae Gyu; Kim, Jin Kon; Cho, Hyun; Lee, Byeong Woo

    2015-03-01

    Inductively coupled plasma etching of ultrananocrystalline diamond (UNCD) films was performed in O2/CF4 and O2/SF6 discharges. Higher etch rates were produced for the O2/SF6 discharges and the films etched in the 10O2/5CF4 discharges retained smooth surface morphology similar to the unetched control sample. Al mask showed a good etch selectivity to the UNCD for both plasma chemistries and highly anisotropic pattern transfer with a vertical sidewall profile was achieved.

  2. Preparation of thin Si:H films in an inductively coupled plasma reactor and analysis of their surface roughness

    International Nuclear Information System (INIS)

    Zhao Wenfeng; Chen Junfang; Meng Ran; Wang Yang; Wang Hui; Guo Chaofeng; Xue Yongqi

    2010-01-01

    An important concern in the deposition of Si:H films is to obtain smooth surfaces. Herein, we deposit the thin Si:H films using Ar-diluted SiH 4 as feedstock gas in an inductively coupled plasma reactor. And we carry a real-time monitor on the deposition process by using optical emission spectrum technology in the vicinity of substrate and diagnose the Ar plasma radial distribution by Langmuir probe. Surface detecting by AFM and surface profilometry in large scale shows that the thin Si:H films have small surface roughness. Distributions of both the ion density and the electron temperature are homogeneous at h = 0.5 cm. Based on these experimental results, it can be proposed inductively coupled plasma reactor is fit to deposit the thin film in large scale. Also, Ar can affect the reaction process and improve the thin Si:H films characteristics.

  3. Measurement of excitation, ionization, and electron temperatures and positive ion concentrations in a 144 MHz inductively coupled radiofrequency plasma

    International Nuclear Information System (INIS)

    Walters, P.E.; Chester, T.L.; Winefordner, J.D.

    1977-01-01

    Diagnostic measurements of 144 MHz radiofrequency inductively coupled plasmas at pressures between 0.5 and 14 Torr have been made. Other variables studied included the gas type (Ar or Ne) and material in plasma (Ti or Tl). Parameters measured included excitation temperatures via the atomic Boltzmann plot and the two-line method, ionization electric probes. Excitation temperatures increased as the pressure of Ar or Ne plasmas decreased and reached a maximum of approx.9000 degreeK in the latter case and approx.6700 degreeK in the former case; Tl in the Ar plasma resulted in in a smaller rate of decrease of excitation temperature with increase of pressure of Ar. The ionization temperatures were lower than the excitation temperatures and were similar for both the Ar and Ne plasmas. Electron temperatures were about 10 times higher than the excitation temperatures indicating non-LTE behavior. Again, the electron temperatures indicating in Ne were considerably higher than in Ar. With the presence of metals, the electron temperatures with a metal in the Ar plasma were higher than in the absence. Positive ion concentrations were also measured for the various plasmas and were found to be similar (approx.10 18 m -3 ) in both the Ar and Ne plasmas. The presence of metals caused significant increase in the positive ion concentrations. From the results obtained, the optimum Ar pressure for Tl electrodeless discharge lamps operated at 144 MHz would be between 2 and 4 Torr

  4. Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry.

    Science.gov (United States)

    Zhu, Bangjie; Liu, Feng; Li, Xituo; Wang, Yan; Gu, Xue; Dai, Jieyu; Wang, Guiming; Cheng, Yu; Yan, Chao

    2015-01-01

    Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at -20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Studies of the inductively coupled plasma via tomographic reconstruction: II. Experimental system

    International Nuclear Information System (INIS)

    Marshall, K.A.; Monnig, C.A.; Rayson, G.D.; Hieftje, G.M.

    1986-01-01

    Spatially resolved diagnostic studies of the Inductively Coupled Plasma (ICP) have generally relied upon the Abel inversion process to transform lateral projection data into radially resolved emission or absorption profiles. Unfortunately, Abel transformation is known to possess several significant drawbacks. The validity of the radial profiles obtained from the Abel-inversion process is significantly degraded by even small amounts of noise in the lateral emission data. In addition, the Abel-inversion technique requires a cylindrically symmetrical object in order to faithfully produce reconstructions. One method of avoiding these problems is to use the more general method of tomographic reconstruction for spatially resolved studies in the ICP. The experimental requirements of tomographic reconstruction, however, necessitate a rather elaborate experimental system. The large number of angular projections, resolution elements per projection, and the sheer volume of data collected makes tomographic reconstruction prohibitively time consuming if an automated, multi-channel collection scheme is not employed. In this study, an experimental system was designed to permit tomographic characterization of a laboratory ICP. The system employs a z-theta translation stage, a silicon intensified target vidicon detector and a laboratory computer for system automation (see figure). A typical data collection scheme is to obtain 60 projections with 100-point resolution per projection. These profiles are collected every 2 mm on the vertical axis, requiring 15 profiles over a 30 mm plasma height. This process results in approximately 90,000 data points, which can be collected within an hour on this system. Tomographic reconstruction is achieved with the use of a VAX-780 computer. The system employed is described and the operating characteristics of the apparatus are discussed

  6. Synergistic cross-scale coupling of turbulence in a tokamak plasma

    Energy Technology Data Exchange (ETDEWEB)

    Howard, N. T., E-mail: nthoward@psfc.mit.edu [Oak Ridge Institute for Science and Education (ORISE), Oak Ridge, Tennessee 37831 (United States); Holland, C. [University of California - San Diego, La Jolla, California 92093 (United States); White, A. E.; Greenwald, M. [MIT - Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Candy, J. [General Atomics, P.O. Box 85608, San Diego, California 92186 (United States)

    2014-11-15

    For the first time, nonlinear gyrokinetic simulations spanning both the ion and electron spatio-temporal scales have been performed with realistic electron mass ratio ((m{sub D}∕m{sub e}){sup 1∕2 }= 60.0), realistic geometry, and all experimental inputs, demonstrating the coexistence and synergy of ion (k{sub θ}ρ{sub s}∼O(1.0)) and electron-scale (k{sub θ}ρ{sub e}∼O(1.0)) turbulence in the core of a tokamak plasma. All multi-scale simulations utilized the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] to study the coupling of ion and electron-scale turbulence in the core (r/a = 0.6) of an Alcator C-Mod L-mode discharge shown previously to exhibit an under-prediction of the electron heat flux when using simulations only including ion-scale turbulence. Electron-scale turbulence is found to play a dominant role in setting the electron heat flux level and radially elongated (k{sub r} ≪ k{sub θ}) “streamers” are found to coexist with ion-scale eddies in experimental plasma conditions. Inclusion of electron-scale turbulence in these simulations is found to increase both ion and electron heat flux levels by enhancing the transport at the ion-scale while also driving electron heat flux at sub-ρ{sub i} scales. The combined increases in the low and high-k driven electron heat flux may explain previously observed discrepancies between simulated and experimental electron heat fluxes and indicates a complex interaction of short and long wavelength turbulence.

  7. The influence of gas pressure on E↔H mode transition in argon inductively coupled plasmas

    Science.gov (United States)

    Zhang, Xiao; Zhang, Zhong-kai; Cao, Jin-xiang; Liu, Yu; Yu, Peng-cheng

    2018-03-01

    Considering the gas pressure and radio frequency power change, the mode transition of E↔H were investigated in inductively coupled plasmas. It can be found that the transition power has almost the same trend decreasing with gas pressure, whether it is in H mode or E mode. However, the transition density increases slowly with gas pressure from E to H mode. The transition points of E to H mode can be understood by the propagation of electromagnetic wave in the plasma, while the H to E should be illustrated by the electric field strength. Moreover, the electron density, increasing with the pressure and power, can be attributed to the multiple ionization, which changes the energy loss per electron-ion pair created. In addition, the optical emission characteristics in E and H mode is also shown. The line ratio of I750.4 and I811.5, taken as a proxy of the density of metastable state atoms, was used to illustrate the hysteresis. The 750.4 nm line intensity, which has almost the same trend with the 811.5 nm line intensity in H mode, both of them increases with power but decreases with gas pressure. The line ratio of 811.5/750.4 has a different change rule in E mode and H mode, and at the transition point of H to E, it can be one significant factor that results in the hysteresis as the gas pressure change. And compared with the 811.5 nm intensity, it seems like a similar change rule with RF power in E mode. Moreover, some emitted lines with lower rate constants don't turn up in E mode, while can be seen in H mode because the excited state atom density increasing with the electron density.

  8. [Determination of 24 minerals in human milk by inductively coupled plasma mass spectrometry with microwave digestion].

    Science.gov (United States)

    Sun, Zhongqing; Yue, Bing; Yang, Zhenyu; Li, Xiaowei; Wu, Yongning; Yin, Shian

    2013-05-01

    To determine the levels of 24 minerals in human milk by inductively coupled plasma mass spectrometry with microwave digestion. The samples were digested by microwave. The contents of minerals were determined by inductively coupled plasma mass spectrometry. The standard reference minerals of 1849a and 1568a from National Institute of Science and Technology were used for quality control. The accuracy and reproduability for this method were evaluated with mix standards and 1849a and 1568a standard reference materials. The ranges of the levels of sodium, magnesium, phosphorus, potassium, calcium, aluminum, chromium, arsenic, selenium, iron, zinc, manganese, copper, molybdenum, vanadium, cobalt, nickel, gallium, cadmium, silver, strontium, cesium, barium, lead in human milk was 34.97-415.83 mg/kg, 19.00-39.52 mg/kg, 102.13-274.53 mg/kg, 351.19-713.99 mg/kg, 180.08-349.64 mg/kg, 0.06-0.44 mg/kg, 0.9-7.37 microg/kg, 0.92-2.72 microg/kg, 0.20-21.15 microg/kg, 0.10-0.70 mg/kg, 0.56-3.25 mg/kg, 3.00-16.12 micro.g/kg, 62.16-591.69 microg/kg, 0.02-6.91 microg/kg, 5.99-13.70 microg/kg, 0.07-2.11 microg/kg, 0.77-209.26 microg/kg, 0.005-0.28 microg/kg, 0.02-0.23 microg/kg, 0.02-0.71 microg/kg, 36.89-132.26 microg/kg, 0.01-4.72 microg/kg, 0.83-28.16 microg/kg, 2.5-5.3 microg/kg, respectively. The levels of minerals in human milk in present study were consisted with other similar studies. The experiment examined the levels of minerals in human milk satisfactorily. The method has high accuracy and good reproducibility, which could be used for understanding the levels of minerals in human milk.

  9. Inductively coupled plasma-atomic emission spectroscopy glovebox assembly system at the West Valley Demonstration Project

    International Nuclear Information System (INIS)

    Marlow, J.H.; McCarthy, K.M.; Tamul, N.R.

    1999-01-01

    The inductively coupled plasma/atomic emission spectroscopy [ICP/AES (ICP)] system for elemental analyses in support of vitrification processing was first installed in 1986. The initial instrument was a Jobin Yvon (JY) Model JY-70 ICP that consisted of sequential and simultaneous spectrometers for analysis of nonradioactive samples as radioactive surrogates. The JY-70 ICP continued supporting nonradioactive testing during the Functional and Checkout Testing of Systems (FACTS) using the full-scale melter with ''cold'' (nonradioactive) testing campaigns. As a result, the need for another system was identified to allow for the analysis of radioactive samples. The Mass Spec (Spectrometry) Lab was established for the installation of the modified ICP system for handling radioactive samples. The conceptual setup of another ICP was predicated on the use of a hood to allow ease of accessibility of the torch, nebulizer, and spray chamber, and the minimization of air flow paths. However, reconsideration of the radioactive sample dose rate and contamination levels led to the configuration of the glovebox system with a common transfer interface box for the ICP and the inductively coupled plasma-mass spectrometer (ICP-MS) glovebox assemblies. As a result, a simultaneous Model JY-50P ICP with glovebox was installed in 1990 as a first generation ICP glovebox system. This was one of the first ICP glovebox assemblies connected with an ICP-MS glovebox system. Since the economics of processing high-level radioactive waste (HLW) required the availability of an instrument to operate 24 hours a day throughout the year without any downtime, a second generation ICP glovebox assembly was designed, manufactured, and installed in 1995 using a Model JY-46P ICP. These two ICP glovebox systems continue to support vitrification of the HLW into canisters for storage. The ICP systems have been instrumental in monitoring vitrification batch processing. To date, remote sample preparation and

  10. Inductively coupled plasma -- Atomic emission spectroscopy glove box assembly system at the West Valley Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Marlow, J.H.; McCarthy, K.M.; Tamul, N.R.

    1999-12-17

    The inductively coupled plasma/atomic emission spectroscopy [ICP/AES (ICP)] system for elemental analyses in support of vitrification processing was first installed in 1986. The initial instrument was a Jobin Yvon (JY) Model JY-70 ICP that consisted of sequential and simultaneous spectrometers for analysis of nonradioactive samples as radioactive surrogates. The JY-70 ICP continued supporting nonradioactive testing during the Functional and Checkout Testing of Systems (FACTS) using the full-scale melter with ``cold'' (nonradioactive) testing campaigns. As a result, the need for another system was identified to allow for the analysis of radioactive samples. The Mass Spec (Spectrometry) Lab was established for the installation of the modified ICP system for handling radioactive samples. The conceptual setup of another ICP was predicated on the use of a hood to allow ease of accessibility of the torch, nebulizer, and spray chamber, and the minimization of air flow paths. However, reconsideration of the radioactive sample dose rate and contamination levels led to the configuration of the glovebox system with a common transfer interface box for the ICP and the inductively coupled plasma-mass spectrometer (ICP-MS) glovebox assemblies. As a result, a simultaneous Model JY-50P ICP with glovebox was installed in 1990 as a first generation ICP glovebox system. This was one of the first ICP glovebox assemblies connected with an ICP-MS glovebox system. Since the economics of processing high-level radioactive waste (HLW) required the availability of an instrument to operate 24 hours a day throughout the year without any downtime, a second generation ICP glovebox assembly was designed, manufactured, and installed in 1995 using a Model JY-46P ICP. These two ICP glovebox systems continue to support vitrification of the HLW into canisters for storage. The ICP systems have been instrumental in monitoring vitrification batch processing. To date, remote sample preparation

  11. Inductively Coupled Plasma Optical Emission Spectrometry for Rare Earth Elements Analysis

    Science.gov (United States)

    He, Man; Hu, Bin; Chen, Beibei; Jiang, Zucheng

    2017-01-01

    Inductively coupled plasma optical emission spectrometry (ICP-OES) merits multielements capability, high sensitivity, good reproducibility, low matrix effect and wide dynamic linear range for rare earth elements (REEs) analysis. But the spectral interference in trace REEs analysis by ICP-OES is a serious problem due to the complicated emission spectra of REEs, which demands some correction technology including interference factor method, derivative spectrum, Kalman filtering algorithm and partial least-squares (PLS) method. Matrix-matching calibration, internal standard, correction factor and sample dilution are usually employed to overcome or decrease the matrix effect. Coupled with various sample introduction techniques, the analytical performance of ICP-OES for REEs analysis would be improved. Compared with conventional pneumatic nebulization (PN), acid effect and matrix effect are decreased to some extent in flow injection ICP-OES, with higher tolerable matrix concentration and better reproducibility. By using electrothermal vaporization as sample introduction system, direct analysis of solid samples by ICP-OES is achieved and the vaporization behavior of refractory REEs with high boiling point, which can easily form involatile carbides in the graphite tube, could be improved by using chemical modifier, such as polytetrafluoroethylene and 1-phenyl-3-methyl-4-benzoyl-5-pyrazone. Laser ablation-ICP-OES is suitable for the analysis of both conductive and nonconductive solid samples, with the absolute detection limit of ng-pg level and extremely low sample consumption (0.2 % of that in conventional PN introduction). ICP-OES has been extensively employed for trace REEs analysis in high-purity materials, and environmental and biological samples.

  12. Dynamic investigation of mode transition in inductively coupled plasma with a hybrid model

    International Nuclear Information System (INIS)

    Zhao Shuxia; Gao Fei; Wang Younian

    2009-01-01

    Industrial inductively coupled plasma (ICP) sources are always operated in low gas pressure 10-100 mTorr, therefore in order to accurately investigate the mode transition of ICP, we developed our pure fluid model (2009 J. Appl. Phys. 105 083306) into a hybrid fluid/Monte Carlo (MC) model, where the MC part is exploited to take in more dynamic characteristics of electrons and self-consistently calculate the rate coefficients and electron temperature used in the fluid module, and more crucially to study the electron energy distribution function (EEDF) evolution with mode transition. Due to the introduction of the nonlocal property of the electrons at relatively low pressures, the dependences of the plasma density on the coil current, including the mode transitions, are distinctly different at low and high pressures when simulated by this improved hybrid model (HM), while the trends for different pressures obtained from the original pure fluid model (PFM) are the same in all cases. Furthermore, the computed peaks of the electron density profile by the HM shift from the discharge centre in the E mode to the intense inductive field heating area (about half of the radius of the reaction chamber under the dielectric window) in H mode. In addition, the electron temperature profiles of two modes under different pressures simulated by HM are totally higher than the results of PFM. When the pressure is low, there is a minimum exhibited in the bulk plasma of the electron temperature profiles of the E mode, and along with the mode transition the distribution area of low temperature is substantially reduced. Moreover, this phenomenon disappears when the gas pressure is increased. Accompanied by this, the calculated EEDF of the E mode in the low pressure also demonstrates an absolutely dominant low energy electron fraction (about ≤5 eV); while transforming to the H discharge most of the electrons carry an energy of 1-10 eV. The tendencies of the calculated EEDF evolution with

  13. Strongly coupled coulomb systems of dust particles in traps and plasmas

    International Nuclear Information System (INIS)

    Petrov, O.F.; Fortov, V.E.

    2011-01-01

    Complete text of publication follows. After first experimental observations of ordered structures of dust particles in rf and dc gas discharges, similar dusty plasma structures are frequently considered as a macroscopic physical model of coupled Coulomb systems (SCCS), which can visually be observed. Using such structures of charged dust particles, one can investigate the processes of phase transitions, waves, and instabilities on kinetic levels. One of the central problems associated with experimental studies of stable SCCS is that of ensuring the levitation of charged particles. The levitation of dust particles in gas discharges is provided by the interaction of the particle charge with electric field. For confinement and investigation of SCCS of charged dust particles, we propose to use a trap based on the known possibility of the levitation of diamagnetic bodies in a nonuniform steady-state magnetic field. An experimental setup is described, which is capable of forming and confining clusters of charge graphite particles sized 100 to 300 μm in magnetic field B∼1 T and |V-barB| ∼10 T/cm. It is inferred that it will be possible to form stable 3d dust structures containing several thousand particles under terrestrial conditions by using more intensive magnetic fields B > 10 T. Less intensive magnetic fields (B ∼ 0.1 T, |V-barB| ∼ 0.1 T/cm) will be required for studying analogous structures under microgravity conditions. The superhigh charging of dust particles under direct stimulation by an electron beam is experimentally investigated. The energy of beam electrons amounts to 25 keV, with the typical diameter of dust particles employed in the experiment of 100 μm. The charge acquired by a dust particle amounts to 5·10 7 electron charges, which is more than two orders of magnitude higher than the values of the charge of dust particles in gas discharges. A technique for analyzing the pair interaction forces between particles in nonideal dissipative systems

  14. Electrical description of a magnetic pole enhanced inductively coupled plasma source: Refinement of the transformer model by reverse electromagnetic modeling

    International Nuclear Information System (INIS)

    Meziani, T.; Colpo, P.; Rossi, F.

    2006-01-01

    The magnetic pole enhanced inductively coupled source (MaPE-ICP) is an innovative low-pressure plasma source that allows for high plasma density and high plasma uniformity, as well as large-area plasma generation. This article presents an electrical characterization of this source, and the experimental measurements are compared to the results obtained after modeling the source by the equivalent circuit of the transformer. In particular, the method applied consists in performing a reverse electromagnetic modeling of the source by providing the measured plasma parameters such as plasma density and electron temperature as an input, and computing the total impedance seen at the primary of the transformer. The impedance results given by the model are compared to the experimental results. This approach allows for a more comprehensive refinement of the electrical model in order to obtain a better fitting of the results. The electrical characteristics of the system, and in particular the total impedance, were measured at the inductive coil antenna (primary of the transformer). The source was modeled electrically by a finite element method, treating the plasma as a conductive load and taking into account the complex plasma conductivity, the value of which was calculated from the electron density and electron temperature measurements carried out previously. The electrical characterization of the inductive excitation source itself versus frequency showed that the source cannot be treated as purely inductive and that the effect of parasitic capacitances must be taken into account in the model. Finally, considerations on the effect of the magnetic core addition on the capacitive component of the coupling are made

  15. Improved performance of a shielded torch using ethanol in inductively coupled plasma–sector field mass spectrometry

    International Nuclear Information System (INIS)

    Chen, Tao; Hu, Zhaochu; Liu, Shenghua; Liu, Yongsheng; Gao, Shan; Li, Ming; Zong, Keqing; Chen, Haihong; Hu, Shenghong

    2015-01-01

    To improve the accuracy and precision of trace element analysis, higher analytical sensitivity and lower interference are required. In this study, we investigated the effects of the addition of ethanol in combination with a shielded torch on the signal intensities of elements from 7 Li to 238 U, oxide yields, doubly charged ion yields, isobaric interferences and ion distributions in inductively coupled plasma–sector field mass spectrometry (ICP–SFMS). For the 39 investigated elements in this study, using the shielded torch increases the sensitivity by a factor of 17–58. The well-known drawback of using a shielded torch is that it will increase the oxide yield. In this study, the CeO + /Ce + ratio is increased by a factor of 3.3 in the GE-on mode compared to that in the GE-off mode at normal conditions (without ethanol). In the GE-on mode, the addition of 4% ethanol in ICP–SFMS is found not only to decrease the CeO + /Ce + ratio by a factor of 4 but also to suppress the Ce 2+ /Ce + ratio by a factor of 4.2. In large contrast, the effect of 2–6% ethanol on the oxide yield and doubly charged ratio is minimal in the GE-off mode. Except for As, Se, Sb, Te and Au, for which the signal intensities are increased by a factor of 1.4–3.7 in the presence of 2–6% ethanol, an increased concentration of ethanol suppresses intensities of other elements. In the GE-off mode, the suppression of the analyte signal due to increased ethanol concentration is more significant than that in the GE-on mode. Compared to the spatial profiles of the ion distributions in the normal mode (without ethanol), the addition of 2–4% ethanol leads to significantly wider axial and radial profiles. The significantly wider axial and radial ion distribution had a dilution effect on the ion densities, which subsequently reduced the ion signal intensities. The addition of 4% ethanol was also found to suppress the interferences of Xe by a factor of 2.8 and increase the sensitivity of Te

  16. Numerical simulation of the argon-hydrogen plasma flow in the channel of RF inductively coupled plasma torch

    Science.gov (United States)

    Grishin, Yu. M.; Long, Miao

    2017-11-01

    The results of numerical simulation of plasma flow in the channel of technological radio frequency (RF) plasma torch with three coils and frequency at 3 MHz are presented. The mixture of argon with hydrogen is considered as the working gas at a variation of hydrogen volume fraction α from 0 to 10%. The distributions of electromagnetic fields and gas-dynamic parameters of the plasma flow are calculated. It is shown that when the amplitude of discharge current exceeds the critical value Jcr (depends on α), the regime of plasma flow transforms from the potential to vortical regime, in which a toroidal vortex is formed before or in the inductor zone. The dependence of the values of the critical current Jcr on the volume concentration of hydrogen α is established. The influences of volume fraction α and discharge current Jcoil on the intensities and the position of the vortex center are determined.

  17. Comparison of femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for uranium isotopic measurements

    Energy Technology Data Exchange (ETDEWEB)

    Havrilla, George Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McIntosh, Kathryn Gallagher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Judge, Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Dirmyer, Matthew R. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Campbell, Keri [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gonzalez, Jhanis J. [Applied Spectra Inc., Fremont, CA (United States)

    2016-10-20

    Feasibility tests were conducted using femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry for rapid uranium isotopic measurements. The samples used in this study consisted of a range of pg quantities of known 235/238 U solutions as dried spot residues of 300 pL drops on silicon substrates. The samples spanned the following enrichments of 235U: 0.5, 1.5, 2, 3, and 15.1%. In this direct comparison using these particular samples both pulse durations demonstrated near equivalent data can be produced on either system with respect to accuracy and precision. There is no question that either LA-ICP-MS method offers the potential for rapid, accurate and precise isotopic measurements of U10Mo materials whether DU, LEU or HEU. The LA-ICP-MS equipment used for this work is commercially available. The program is in the process of validating this work for large samples using center samples strips from Y-12 MP-1 LEU-Mo Casting #1.

  18. The application of the inductively coupled plasma system to the simultaneous determination of precious metals

    International Nuclear Information System (INIS)

    Watson, A.E.; Russell, G.M.; Middleton, H.R.; Davenport, F.F.

    1983-01-01

    This report describes the development of a spectrochemical technique using excitation by an inducticely coupled plasma (ICP) source for the simultaneous determination of the precious metals (defined here as gold, silver, and all the platinum-group metals except osmium) in a wide variety of samples from a plant for the extraction and refining of platinum metal. The limits of detection for the analytes were determined in various acid and salt media and, under the conditions used, ranged from 20 to 100ng/l. The analytes were determined in the presence of a thousandfold excess of each of the other precious metals used as a matrix element. Some severe interferences were noted but were ascribed to spectral-line overlap or to contamination of the matrix material. Various dissolution techniques, based upon standard procedures applied in the precious-metals industry, were used, depending on the particular type of material treated. The spectrometer was calibrated by the use of solutions containing the analytes, sodium chloride, and acid, with scandium as the internal standard. The accuracy and precision of the technique, established by the analysis of many samples of each type, were found to be satisfactory when close attention was paid to detail in the preparation of the analytical solution. The relative standard deviation of the method ranges from 0,005 to 0,05, depending on the element being determined

  19. In vivo antibiotic removal during coupled plasma filtration adsorption: a retrospective study.

    Science.gov (United States)

    Page, Mathieu; Cohen, Sabine; Ber, Charles-Eric; Allaouchiche, Bernard; Kellum, John A; Rimmelé, Thomas

    2014-01-01

    Coupled plasma filtration adsorption (CPFA) is a blood purification therapy aimed at modulating the host inflammatory response involved in sepsis pathogenesis. One potential drawback of this technique is the unexpected elimination of antibiotics. The aim of this study was to assess the elimination of several antibiotics with CPFA. We performed a retrospective analysis of the serum and ultrafiltrate concentrations of different antibiotics routinely measured during CPFA sessions in five patients experiencing septic shock. The adsorbent extraction ratio (AER) for piperacillin and vancomycin 2 h into the CPFA session were high: 95.4 ± 6.9% and 99.6 ± 0.9%, respectively. These AER decreased significantly by 8 h (at 8 h: 6.3 ± 51.8% and -30.2 ± 25.6%, respectively), suggesting saturation of the resin cartridge. Conversely, the tazobactam AER was low (7.2 ± 15% after 2 h of CPFA). No significant changes in the mean serum concentrations of piperacillin, tazobactam, and vancomycin were observed. Thus, as opposed to tazobactam, we report high adsorption of piperacillin and vancomycin on the CPFA resin but with no reduction in serum concentrations.

  20. Levels of Essential Elements in Different Medicinal Plants Determined by Using Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Eid I. Brima

    2018-01-01

    Full Text Available The objective of this study was to investigate the content of essential elements in medicinal plants in the Kingdom of Saudi Arabia (KSA. Five different medical plants (mahareeb (Cymbopogon schoenanthus, sheeh (Artemisia vulgaris, harjal (Cynanchum argel delile, nabipoot (Equisetum arvense, and cafmariam (Vitex agnus-castus were collected from Madina city in the KSA. Five elements Fe, Mn, Zn, Cu, and Se were determined by using inductively coupled plasma mass spectrometry (ICP-MS. Fe levels were the highest and Se levels were the lowest in all plants. The range levels of all elements in all plants were as follows: Fe 193.4–1757.9, Mn 23.6–143.7, Zn 15.4–32.7, Se 0.13–0.92, and Cu 11.3–21.8 µg/g. Intakes of essential elements from the medical plants in infusion were calculated: Fe 4.6–13.4, Mn 6.7–123.2, Zn 7.0–42.7, Se 0.14–1.5, and Cu 1.5–5.0 µg/dose. The calculated intakes of essential elements for all plants did not exceed the daily intake set by the World Health Organization (WHO and European Food Safety Authority (EFSA. These medicinal plants may be useful sources of essential elements, which are vital for health.

  1. Establishing human heart chromium, cobalt and vanadium concentrations by inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Day, Patrick L; Eckdahl, Steven J; Maleszewski, Joseph J; Wright, Thomas C; Murray, David L

    2017-05-01

    Chromium, cobalt, and vanadium are used in metallic joint prosthesis. Case studies have associated elevated heart tissue cobalt concentrations with myocardial injury. To document the long term heart metal ion concentrations, a validated inductively coupled plasma mass spectroscopy (ICP-MS) method was needed. The method utilized a closed-vessel microwave digestion system to digest the samples. An ICP-MS method utilizing Universal Cell Technology was used to determine our target analyte concentrations. Accuracy was verified using reference materials. Precision, sensitivity, recovery and linearity studies were performed. This method was used to establish a reference range for a non-implant containing cohort of 80 autopsy human heart tissues RESULTS: This method demonstrated an analytic measurement range of 0.5-100ng/mL for each element. Accuracy was within ±10% of target value for each element. Within-run precision for each element was below 20% CV. The chromium, vanadium and cobalt concentrations (mean±SD) were 0.1523±0.2157μg/g, 0.0094±0.0211μg/g and 0.1039±0.1305μg/g respectively in 80 non-implant containing human heart tissue samples. This method provides acceptable recovery of the chromium, cobalt and vanadium in heart tissue; allowing assessment of the effects of metallic joint prosthesis on myocardial health. Copyright © 2017 Elsevier GmbH. All rights reserved.

  2. Determination of metals content from wines by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Iordache, Andreea-Maria; Geana, Elisabeta-Irina

    2009-01-01

    Full text: Wine is a widely consumed beverage with thousands of years of tradition. Wine composition strongly determines its quality besides having a great relevance on wine characterization, tipyfication and frauds detection. Wine composition is influenced by many and diverse factors corresponding to the specific production area, such as grape variety, soil and climate, culture, yeast, winemaking practices, transport and storage. Daily consumption of wine in moderate quantities contributes significantly to the requirements of the human organism for essential elements such as Cr, Cu, Zn, Fe, Mn, Co, Ni and Sr. On the other hand, several metals, such as Pb and Cd , are known to be potentially toxic. The objective of this work was to develop a method to determine the metals content in wine samples from Romania. Three samples of difference white wines available in the supermarket was analyzed for identify the presence of: Cr, Cu, Zn, Fe, Mn, Pb, Cd, Co, Ni and Sr by inductively coupled plasma mass spectrometry (ICP-MS). (authors)

  3. Determination of zinc stable isotopes in biological materials using isotope dilution inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Patterson, K.Y.; Veillon, Claude

    1992-01-01

    A method is described for using isotope dilution to determine both the amount of natural zinc and enriched isotopes of zinc in biological samples. Isotope dilution inductively coupled plasma mass spectrometry offers a way to quantify not only the natural zinc found in a sample but also the enriched isotope tracers of zinc. Accurate values for the enriched isotopes and natural zinc are obtained by adjusting the mass count rate data for measurable instrumental biases. Analytical interferences from the matrix are avoided by extracting the zinc from the sample matrix using diethylammonium diethyldithiocarbamate. The extraction technique separates the zinc from elements which form interfering molecular ions at the same nominal masses as the zinc isotopes. Accuracy of the method is verified using standard reference materials. The detection limit is 0.06 μg Zn per sample. Precision of the abundance ratios range from 0.3-0.8%. R.S.D. for natural zinc concentrations is about 200-600 μg g -1 . The accuracy and precision of the measurements make it possible to follow enriched isotopic tracers of zinc in biological samples in metabolic tracer studies. (author). 19 refs.; 1 fig., 4 tabs

  4. Etching characteristics of Au thin films using inductively coupled Cl2/Ar plasma

    International Nuclear Information System (INIS)

    Chang, Yun Seong; Kim, Dong Pyo; Kim, Chang Il; Sim, Kwee Bo; Chang, Eui Goo

    2003-01-01

    In this study, Au thin films were etched with a Cl 2 /Ar gas combination using inductively coupled plasma. The etch properties were measured for different gas mixing ratios of Cl 2 /(Cl 2 +Ar) while the other process conditions were fixed at a rf power of 700 W, a dc bias voltage of -150 V, a chamber pressure of 15 m Torr and a substrate temperature of 30 .deg. C. The highest etch rate of the Au thin film was 3500 A/min and the selectivity of Au to SiO 2 was 4.4 at a Cl 2 /(CI 2 +Ar) gas mixing ratio of 0.2. The surface reaction of the etched Au thin films was investigated using x-ray photoelectron spectroscopy (XPS) analysis. There is a chemical reaction between Cl and Au. Au-Cl is hard to remove from the surface because of its high melting point. The etching products can be sputtered by Ar ion bombardment. We obtained the clean and steep profile

  5. Profiling metals in Cordyceps sinensis by using inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Wei, Xin; Hu, Hankun; Zheng, Baogeng; Arslan, Zikri; Huang, Hung-Chung; Mao, Weidong; Liu, Yi-Ming

    2017-01-28

    Cordyceps sinensis ( C. sinensis ) is a natural product that has diverse nutritional and medicinal values. Since the availability of natural C. sinensis becomes limited its authentication and quality control is of high significance. Herein we report on profiling of metals in C. sinensis by using inductively coupled plasma mass spectrometry (ICP-MS). The analysis reveals that C. sinensis contains a wide array of essential elements, including P, Mg, Zn, Cu, Fe, etc. Toxic metals detected are Cd, Pb, and As. In all five samples analyzed Pb contents are below 2.0 ppm. Arsenic level in C. sinensis caterpillar is significantly higher than that in its mycelium and varies from 3.0 to 32 ppm likely due to soil contamination. It's for the first time demonstrated in this work that clustering analysis on the proposed metal profiles consisting of 24 elements is very useful to identify "abnormal" C. sinensis samples, thus adding another dimension to the effective means for authentication and quality assessment of this highly demanded previous natural product.

  6. Determination of 238U in marine organisms by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Ishii, Toshiaki; Nakahara, Motokazu; Matsuba, Mitsue; Ishikawa, Masafumi

    1991-01-01

    Determination of 238 U in fifty-five species of marine organisms was carried out by inductively coupled plasma mass spectrometry which showed some advantages such as high sensitivity, wide dynamic range and small interferences from matrices for the analysis of high mass elements. The concentrations of 238 U in soft tissues of marine animals ranged from 0.076 to 5000 ng/g wet wt. Especially, the branchial heart of cephalopod molluscs showed the specific accumulation of 238 U. The concentration factor of the branchial heart of Octopus vulgaris, which indicated the highest value, was calculated to be about 10 3 by comparing it with the concentration of 238 U (3.2±0.2 ng/ml) in coastal seawaters of Japan. The concentrations of 238 U in hard tissues of marine invertebrates were similar to those in soft tissues. In contrast, hard tissues like bone, scale, fin, etc. of fishes showed much higher concentrations of 238 U than soft tissues like muscle and liver. The concentrations of 238 U of twenty species of algae ranged from 10 to 3700 ng/g dry wt. (author)

  7. Determination of trace elements in refined gold samples by inductively coupled plasma atomic emission spectrometry

    Directory of Open Access Journals (Sweden)

    Steharnik Mirjana

    2013-01-01

    Full Text Available This paper presents a method for determination the trace contents of silver, copper, iron, palladium, zinc and platinum in refined gold samples. Simultaneous inductively coupled plasma atomic emission spectrometer with radial torch position and cross flow nebulizer was used for determination. In order to compare the different calibration strategies, two sets of calibration standards were prepared. The first set was based on matrix matched calibration standards and the second was prepared without the addition of matrix material. Detection limits for matrix matching calibrations were higher for some elements than those without matrix matching. In addition, the internal standardization method was applied and experiments indicated that indium was the best option as internal standard. The obtained results for gold sample by matrix matching and matrix free calibrations were compared with the obtained results by standard addition method. The accuracy of the methods was tested performing recovery test. Recoveries for spiked sample were in the range of 90-115 %. The accuracy of the methods was also tested by analysis of certified reference material of high pure goldAuGHP1. The best results were achieved by matrix free calibration and standard addition method using indium as internal standard at wavelength of 230 nm. [Projekat Ministarstva nauke Republike Srbije, br. 34024: Development of Technologies for Recycling of Precious, Rare and Associated Metals from Solid Waste in Serbia to High Purity Products

  8. Heteroepitaxial growth of wafer scale highly oriented graphene using inductively coupled plasma chemical vapor deposition

    International Nuclear Information System (INIS)

    Gao, Libo; Xu, Hai; Li, Linjun; Loh, Kian Ping; Yang, Yang; Fu, Qiang; Bao, Xinhe

    2016-01-01

    The chemical vapor deposition (CVD) of graphene on Cu has attracted much attention because of its industrial scalability. Herein, we report inductively coupled plasma-assisted CVD of epitaxially grown graphene on (111)-textured Cu film alloyed with a small amount of Ni, where large area high quality graphene film can be grown in less than 5 min at 800 °C, thus affording industrial scalability. The epitaxially grown graphene films on (111)-textured Cu contain grains which are predominantly aligned with the Cu lattice and about 10% of 30°-rotated grains (anti-grains). Such graphene films are exclusively monolayer and possess good electrical conductivity, high carrier mobility, and room temperature quantum Hall effect. Magnetoresistance measurements reveal that the reduction of the grain sizes from 150 nm to 50 nm produce increasing Anderson localization and the appearance of a transport gap. Owing to the presence of grain boundaries in these anti-grains, epitaxially grown graphene films possess n-type characteristics and exhibit ultra-high sensitivity to adsorbates. (letter)

  9. Spectral-Kinetic Coupling and Effect of Microfield Rotation on Stark Broadening in Plasmas

    Directory of Open Access Journals (Sweden)

    Alexander V. Demura

    2014-07-01

    Full Text Available The study deals with two conceptual problems in the theory of Stark broadening by plasmas. One problem is the assumption of the density matrix diagonality in the calculation of spectral line profiles. This assumption is closely related to the definition of zero wave functions basis within which the density matrix is assumed to be diagonal, and obviously violated under the basis change. A consistent use of density matrix in the theoretical scheme inevitably leads to interdependence of atomic kinetics, describing the population of atomic states with the Stark profiles of spectral lines, i.e., to spectral-kinetic coupling. The other problem is connected with the study of the influence of microfield fluctuations on Stark profiles. Here the main results of the perturbative approach to ion dynamics, called the theory of thermal corrections (TTC, are presented, within which the main contribution to effects of ion dynamics is due to microfield fluctuations caused by rotations. In the present study the qualitative behavior of the Stark profiles in the line center within predictions of TTC is confirmed, using non-perturbative computer simulations.

  10. Self-similar regimes of turbulence in weakly coupled plasmas under compression

    Science.gov (United States)

    Viciconte, Giovanni; Gréa, Benoît-Joseph; Godeferd, Fabien S.

    2018-02-01

    Turbulence in weakly coupled plasmas under compression can experience a sudden dissipation of kinetic energy due to the abrupt growth of the viscosity coefficient governed by the temperature increase. We investigate in detail this phenomenon by considering a turbulent velocity field obeying the incompressible Navier-Stokes equations with a source term resulting from the mean velocity. The system can be simplified by a nonlinear change of variable, and then solved using both highly resolved direct numerical simulations and a spectral model based on the eddy-damped quasinormal Markovian closure. The model allows us to explore a wide range of initial Reynolds and compression numbers, beyond the reach of simulations, and thus permits us to evidence the presence of a nonlinear cascade phase. We find self-similarity of intermediate regimes as well as of the final decay of turbulence, and we demonstrate the importance of initial distribution of energy at large scales. This effect can explain the global sensitivity of the flow dynamics to initial conditions, which we also illustrate with simulations of compressed homogeneous isotropic turbulence and of imploding spherical turbulent layers relevant to inertial confinement fusion.

  11. Microfluidic high performance liquid chromatography-chip hyphenation to inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Bishop, David P; Blanes, Lucas; Wilson, Alexander B; Wilbanks, Thor; Killeen, Kevin; Grimm, Rudolf; Wenzel, Ross; Major, Derek; Macka, Mirek; Clarke, David; Schmid, Robin; Cole, Nerida; Doble, Philip A

    2017-05-12

    The Agilent Chip Cube Interface is a microfluidic chip-based technology originally designed for nanospray molecular mass spectrometry in which the sample enrichment, nano-column, tubing, connectors and spray tip were integrated into a single biocompatible chip. Here we describe the hyphenation of the Chip Cube Interface to ICP-MS via modification of the standard HPLC chip design and a new total consumption nebuliser suitable for flow rates as low as 300nLmin -1 . The potential of the instrument to eliminate common nanoLC - ICP-MS shortcomings such as leaks, blockages and band-broadening was demonstrated via analysis of cyanocobalamin in equine plasma. The method was linear over three orders of magnitude with an r 2 of 0.9999, the peak area repeatability was 1.9% (n=7), and the detection limit was 14ngmL -1 . This novel configuration of the Chip Cube Interface coupled to ICP-MS is a suitable platform for the analysis of biomolecules associated with trace metals and speciation applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Determination of stable cesium and strontium in rice samples by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Srinuttrakul, W.; Yoshida, S.

    2017-06-01

    For long-term radiation dose assessment models, food ingestion is one of the major exposure pathways to human. In general, the stable isotopes can serve as analogues of radioisotopes. In this study, rice samples were collected from 30 paddy fields in Si Sa Ket, Yasothon and Roi Et in the northeast of Thailand in November 2014. The concentrations of stable cesium (Cs-133) and strontium (Sr-88) in polished rice were determined by inductively coupled plasma mass spectrometry (ICP-MS). The standard reference material of rice flour (NIST 1568a) with spiked Cs and Sr was used to validate the analytical method. The concentration of Cs in polished rice from Si Sa Ket, Yasothon and Roi Et was 0.158 ± 0.167 mg kg-1, 0.090 ± 0.117 mg kg-1 and 0.054 ± 0.031 mg kg-1, respectively. The concentration of Sr in polished rice from Si Sa Ket, Yasothon and Roi Et was 0.351 ± 0.108 mg kg-1, 0.364 ± 0.215 mg kg-1 and 0.287 ± 0.102 mg kg-1, respectively. Comparison of the results with Japanese data before the Fukushima Di-ichi nuclear power plant accident showed that the concentrations of both Cs and Sr for Thai rice were higher than those for Japanese rice.

  13. Upcycling Waste Lard Oil into Vertical Graphene Sheets by Inductively Coupled Plasma Assisted Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Angjian Wu

    2017-10-01

    Full Text Available Vertical graphene (VG sheets were single-step synthesized via inductively coupled plasma (ICP-enhanced chemical vapor deposition (PECVD using waste lard oil as a sustainable and economical carbon source. Interweaved few-layer VG sheets, H2, and other hydrocarbon gases were obtained after the decomposition of waste lard oil. The influence of parameters such as temperature, gas proportion, ICP power was investigated to tune the nanostructures of obtained VG, which indicated that a proper temperature and H2 concentration was indispensable for the synthesis of VG sheets. Rich defects of VG were formed with a high I D / I G ratio (1.29, consistent with the dense edges structure observed in electron microscopy. Additionally, the morphologies, crystalline degree, and wettability of nanostructure carbon induced by PECVD and ICP separately were comparatively analyzed. The present work demonstrated the potential of our PECVD recipe to synthesize VG from abundant natural waste oil, which paved the way to upgrade the low-value hydrocarbons into advanced carbon material.

  14. Holographic RG flow of the shear viscosity to entropy density ratio in strongly coupled anisotropic plasma

    Science.gov (United States)

    Mamo, Kiminad A.

    2012-10-01

    We study holographic RG flow of the shear viscosity tensor of anisotropic, strongly coupled {N}=4 super-Yang-Mills plasma by using its type IIB supergravity dual in anisotropic bulk spacetime. We find that the shear viscosity tensor has three independent components in the anisotropic bulk spacetime away from the boundary, and one of the components has a non-trivial RG flow while the other two have a trivial one. For the component of the shear viscosity tensor with non-trivial RG flow, we derive its RG flow equation, and solve the equation analytically to second order in the anisotropy parameter a. We derive the RG equation using the equation of motion, holographic Wilsonian RG method, and Kubo's formula. All methods give the same result. Solving the equation, we find that the ratio of the component of the shear viscosity tensor to entropy density η /s flows from above 1/{4π } the horizon (IR) to below 1/{4π } the boundary (UV) where it violates the holographic shear viscosity (Kovtun-Son-Starinets) bound and where it agrees with the other longitudinal component.

  15. Elemental Bioimaging by Means of Fast Scanning Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry

    Science.gov (United States)

    Wehe, Christoph A.; Thyssen, Georgina M.; Herdering, Christina; Raj, Indra; Ciarimboli, Giuliano; Sperling, Michael; Karst, Uwe

    2015-08-01

    One of the most common setups for elemental bioimaging, the hyphenation of a laser ablation (LA) system and an inductively coupled plasma mass spectrometer (ICP-MS), was expanded by adding full scan mass spectrometric information as another dimension of information. While most studies deal with the analysis of typically not more than up to 10 isotopes per scan cycle, a fast scanning quadrupole mass analyzer was utilized to record the full mass spectrum of interest in this work. Mass-to-charge ratios from 6 to 250 were observed within one cycle. Besides the x- and y-position on the ablated sample and the intensity, the m/z-ratio served as fourth variable for each pixel of the obtained data, closing thereby the gap between "inorganic" and "organic" mass spectrometric imaging techniques. The benefits of this approach include an improved control of interferences, the discovery of unexpected elemental distributions, the possibility to plot isotopic ratios, and to integrate the intensities of a certain number of mass channels recorded for each isotope, thus virtually increasing sensitivity. The respective data are presented for dried droplets as well as embedded animal and human tissue slices. Limits of detection were calculated and found to be in accordance with counting statistics. A dedicated software macro was developed for data manipulation prior to common evaluation and image creation.

  16. Quantitative images of metals in plant tissues measured by laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietrich, R.C.; Matusch, A.; Pozebon, D.; Dressler, V.L.

    2008-01-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of toxic and essential elements in thin sections (thickness of 30 or 40 μm) of tobacco plant tissues. Two-dimensional images of Mg, Fe, Mn, Zn, Cu, Cd, Rh, Pt and Pb in leaves, shoots and roots of tobacco were produced. Sections of the plant tissues (fixed onto glass slides) were scanned by a focused beam of a Nd:YAG laser in a laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a quadrupole ICP-MS instrument. Ion intensities of the investigated elements were measured together with 13 C + , 33 S + and 34 S + within the entire plant tissue section. Matrix matching standards (prepared using powder of dried tobacco leaves) were used to constitute calibration curves, whereas the regression coefficient of the attained calibration curves was typically 0.99. The variability of LA-ICP-MS process, sample heterogeneity and water content in the sample were corrected by using 13 C + as internal standard. Quantitative imaging of the selected elements revealed their inhomogeneous distribution in leaves, shoots and roots

  17. Studies of selenium and xenon in inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bricker, Tonya [Iowa State Univ., Ames, IA (United States)

    1994-07-27

    Since its development, inductively coupled plasma mass spectrometry (ICP-MS) has been a widely used analytical technique. ICP-MS offers low detection limits, easy determination of isotope ratios, and simple mass spectra from analyte elements. ICP-MS has been successfully employed for many applications including geological, environmental, biological, metallurgical, food, medical, and industrial. One specific application important to many areas of study involves elemental speciation by using ICP-MS as an element specific detector interfaced to liquid chromatography. Elemental speciation information is important and cannot be obtained by atomic spectrometric methods alone which measure only the total concentration of the element present. Part 1 of this study describes the speciation of selenium in human serum by size exclusion chromatography (SEC) and detection by ICP-MS. Although ICP-MS has been widely sued, room for improvement still exists. Difficulties in ICP-MS include noise in the background, matrix effects, clogging of the sampling orifice with deposited solids, and spectral interference caused by polyatomic ions. Previous work has shown that the addition of xenon into the central channel of the ICP decreases polyatomic ion levels. In Part 2 of this work, a fundamental study involving the measurement of the excitation temperature is carried out to further understand xenon`s role in the reduction of polyatomic ions. 155 refs.

  18. Determination of myo-inositol hexakisphosphate (phytate) in urine by inductively coupled plasma atomic emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Grases, F.; Perello, J.; Isern, B.; Prieto, R.M

    2004-05-10

    Myo-inositol hexakisphosphate (phytate) is a substance present in urine with an important role in preventing calcium renal calculi development. In spite of this, the use of urinary phytate levels on stone-formers' evaluation and treatment is still notably restricted as a consequence of the enormous difficulty to analyze this substance in urine. In this paper, a simple procedure for routinary urinary phytate determination based on phosphorus determination through inductively coupled plasma atomic emission spectrometry is described. The method only requires a previous separation of phytate from other components by column anion exchange chromatography. The working linear range used was 0-2 mg l{sup -1} phosphorus (0-7 mg l{sup -1} phytate). The limit of detection was 64 {mu}g l{sup -1} of phytate and the limit of quantification was 213 {mu}g l{sup -1}. The relative standard deviation (R.S.D.) for 1.35 mg l{sup -1} phytate was 2.4%. Different urine samples were analyzed using an alternative analytical methodology based on gas chromatography (GC)/mass detection used for inositol determination (phytate was previously hydrolyzed), resulting both methods comparable using as criterion to assess statistical significance P<0.05.

  19. Precise measurements of neutral gas temperature using Fiber Bragg Grating sensor in Argon capacitively coupled plasmas

    Science.gov (United States)

    Han, Daoman; Liu, Zigeng; Liu, Yongxin; Peng, Wei; Wang, Younian

    2016-09-01

    Neutral gas temperature was measured using Fiber Bragg Grating sensor (FBGs) in capacitively coupled argon plasmas. Thermometry is based on the thermal equilibrium between the sensor and neutral gases, which is found to become faster with increasing pressure. It is also observed that the neutral gas temperature is higher than the room temperature by 10 120 °depending on the experiental conditions, and gas temperature shows significant non-uniformity in space. In addition, radial profiles of neutral temperature at different pressures, resemble these of ion density, obtained by a floating double probe. Specifically, at low pressure, neutral gas temperature and ion density peak at the center of the reactor, while the peak appears at the edge of the electrode at higher pressure. The neutral gas heating is mainly caused by the elastic collisions of Ar + with neutral gas atoms in the sheath region after Ar + gaining a certain energy. This work was supported by the National Natural Science Foundation of China (NSFC) (Grants No. 11335004, 11405018, and 61137005).

  20. Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Todorov, T.I.; Xu, H.; Ejnik, J.W.; Mullick, F.G.; Squibb, K.; McDiarmid, M.A.; Centeno, J.A.

    2009-01-01

    In this study we report depleted uranium (DU) analysis in whole blood samples. Internal exposure to DU causes increased uranium levels as well as change in the uranium isotopic composition in blood specimen. For identification of DU exposure we used the 235U/238U ratio in blood samples, which ranges from 0.00725 for natural uranium to 0.002 for depleted uranium. Uranium quantification and isotopic composition analysis were performed by inductively coupled plasma mass spectrometry. For method validation we used eight spiked blood samples with known uranium concentrations and isotopic composition. The detection limit for quantification was determined to be 4 ng L-1 uranium in whole blood. The data reproduced within 1-5% RSD and an accuracy of 1-4%. In order to achieve a 235U/238U ratio range of 0.00698-0.00752% with 99.7% confidence limit a minimum whole blood uranium concentration of 60 ng L??1 was required. An additional 10 samples from a cohort of veterans exposed to DU in Gulf War I were analyzed with no knowledge of their medical history. The measured 235U/ 238U ratios in the blood samples were used to identify the presence or absence of DU exposure within this patient group. ?? 2009 The Royal Society of Chemistry.

  1. Studies of selenium and xenon in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Bricker, T.

    1994-01-01

    Since its development, inductively coupled plasma mass spectrometry (ICP-MS) has been a widely used analytical technique. ICP-MS offers low detection limits, easy determination of isotope ratios, and simple mass spectra from analyte elements. ICP-MS has been successfully employed for many applications including geological, environmental, biological, metallurgical, food, medical, and industrial. One specific application important to many areas of study involves elemental speciation by using ICP-MS as an element specific detector interfaced to liquid chromatography. Elemental speciation information is important and cannot be obtained by atomic spectrometric methods alone which measure only the total concentration of the element present. Part 1 of this study describes the speciation of selenium in human serum by size exclusion chromatography (SEC) and detection by ICP-MS. Although ICP-MS has been widely sued, room for improvement still exists. Difficulties in ICP-MS include noise in the background, matrix effects, clogging of the sampling orifice with deposited solids, and spectral interference caused by polyatomic ions. Previous work has shown that the addition of xenon into the central channel of the ICP decreases polyatomic ion levels. In Part 2 of this work, a fundamental study involving the measurement of the excitation temperature is carried out to further understand xenon's role in the reduction of polyatomic ions. 155 refs

  2. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    Science.gov (United States)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  3. EVALUATION OF CORROSION OF ENGINEERING CERAMICS BY ATOMIC EMISSION SPECTROMETRY IN INDUCTIVELY COUPLED PLASMA

    Directory of Open Access Journals (Sweden)

    DAGMAR GALUSKOVÁ

    2014-03-01

    Full Text Available An analytical method has been developed and verified, facilitating chemical analysis of saline aqueous solutions from corrosion tests of two types of engineering ceramics, i.e. polycrystalline alumina, and silicon nitride. The method is capable of providing complementary information related to mechanisms of corrosion and kinetics of dissolution of the two main components of the ceramics, i.e. Al in α-Al2O3, and Si in Si3N4. A radially viewed inductively coupled plasma atomic emission spectroscopy was used, and the operating conditions for the analysis were optimised. The method was validated. Internal standardisation, matrix matching, standard addition technique and direct measurement without matrix correction were applied, and the results were critically discussed. The technique of internal standard was shown to be the most sensitive. The method exhibited satisfactory precision (relative standard deviation up to 5 %, analytical recoveries from 95 to 100 %, and acceptable limits of detection based on 3σ criterion of 0.095 mg∙l-1 for Al (measured at 308.215 nm and 0.099 mg∙l-1 for Si (at 251.611 nm.

  4. Fundamental and methodological investigations for the improvement of elemental analysis by inductively coupled plasma mass soectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ebert, Christopher Hysjulien [Ames Lab., Ames, IA (United States)

    2012-01-01

    This dissertation describes a variety of studies meant to improve the analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation (LA) ICP-MS. The emission behavior of individual droplets and LA generated particles in an ICP is studied using a high-speed, high frame rate digital camera. Phenomena are observed during the ablation of silicate glass that would cause elemental fractionation during analysis by ICP-MS. Preliminary work for ICP torch developments specifically tailored for the improvement of LA sample introduction are presented. An abnormal scarcity of metal-argon polyatomic ions (MAr{sup +}) is observed during ICP-MS analysis. Evidence shows that MAr{sup +} ions are dissociated by collisions with background gas in a shockwave near the tip of the skimmer cone. Method development towards the improvement of LA-ICP-MS for environmental monitoring is described. A method is developed to trap small particles in a collodion matrix and analyze each particle individually by LA-ICP-MS.

  5. Inductively coupled plasma mass spectrometer with laser ablation metal ions release detection in the human mouth

    Science.gov (United States)

    Kueerova, Hana; Dostalova, Tatjana; Prochazkova, J.

    2002-06-01

    Presence of more dental alloys in oral cavity often causes pathological symptoms. Due to various and multi-faced symptomatology, they tend to be a source of significant problems not only for the patient but also for the dentist. Metal ions released from alloys can cause subjective and objective symptoms in mouth. The aim of this study was detection of metal elements presence in saliva. There were 4 groups of examined persons: with intact teeth (15 individuals) with metallic restorations, pathological currents 5-30 (mu) A, multi-faced subjective symptomatology and uncharacteristic objective diagnosis (32 patients), with metallic restorations and no subjective symptoms (14 persons) and with metallic restorations, without pathological currents and with problems related to galvanism (13 patients). Presence of 14 metal elements was checked by inductively coupled plasma mass spectrometer with laser ablation. Nd:YAG laser detector was used. There were significant differences in content of silver, gold and mercury between persons with intact teeth and other three groups. There were no differences found between subjects with and without galvanic currents, and presence of subjective and objective symptoms.

  6. Plutonium determination in seawater by inductively coupled plasma mass spectrometry: A review.

    Science.gov (United States)

    Cao, Liguo; Bu, Wenting; Zheng, Jian; Pan, Shaoming; Wang, Zhongtang; Uchida, Shigeo

    2016-05-01

    Knowing the concentration and isotopic ratio of Pu in seawater is of critical importance for assessing Pu contamination and investigating oceanic processes. In recent decades, the concentration of (239+240)Pu in seawater, particularly for surface seawater, has presented an exponential decreasing trend with time; thus determination of Pu in seawater has become a challenge nowadays. Here, we have summarized and critically discussed a variety of reported analytical methods for Pu determination in seawater sample based on inductively coupled plasma mass spectrometry (ICP-MS) analytical technique for rapid ultra-trace detection of Pu. Generally, pretreatments for seawater sample include co-precipitation, valence adjustment and chemical separation and purification procedures, all of which are comprehensively reviewed. Overall, the selected anion-exchange, extraction resins and operation condition are important for decontamination of interference from matrix elements and achieving satisfactory chemical yields. In addition, other mass spectrometric and radiometric detections are briefly addressed and compared with the focus on assessing ICP-MS. Finally, we discuss some issues and prospects in determination and application of Pu isotopes in seawater samples for future research. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Exploration of robust operating conditions in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Tromp, John W.; Pomares, Mario; Alvarez-Prieto, Manuel; Cole, Amanda; Ying Hai; Salin, Eric D.

    2003-01-01

    'Robust' conditions, as defined by Mermet and co-workers for inductively coupled plasma (ICP)-atomic emission spectrometry, minimize matrix effects on analyte signals, and are obtained by increasing power and reducing nebulizer gas flow. In ICP-mass spectrometry (MS), it is known that reduced nebulizer gas flow usually leads to more robust conditions such that matrix effects are reduced. In this work, robust conditions for ICP-MS have been determined by optimizing for accuracy in the determination of analytes in a multi-element solution with various interferents (Al, Ba, Cs, K, Na), by varying power, nebulizer gas flow, sample introduction rate and ion lens voltage. The goal of the work was to determine which operating parameters were the most important in reducing matrix effects, and whether different interferents yielded the same robust conditions. Reduction in nebulizer gas flow and in sample input rate led to a significantly decreased interference, while an increase in power seemed to have a lesser effect. Once the other parameters had been adjusted to their robust values, there was no additional improvement in accuracy attainable by adjusting the ion lens voltage. The robust conditions were universal, since, for all the interferents and analytes studied, the optimum was found at the same operating conditions. One drawback to the use of robust conditions was the slightly reduced sensitivity; however, in the context of 'intelligent' instruments, the concept of 'robust conditions' is useful in many cases

  8. Battery-powered pulsed high density inductively coupled plasma source for pre-ionization in laboratory astrophysics experiments.

    Science.gov (United States)

    Chaplin, Vernon H; Bellan, Paul M

    2015-07-01

    An electrically floating radiofrequency (RF) pre-ionization plasma source has been developed to enable neutral gas breakdown at lower pressures and to access new experimental regimes in the Caltech laboratory astrophysics experiments. The source uses a customized 13.56 MHz class D RF power amplifier that is powered by AA batteries, allowing it to safely float at 3-6 kV with the electrodes of the high voltage pulsed power experiments. The amplifier, which is capable of 3 kW output power in pulsed (<1 ms) operation, couples electrical energy to the plasma through an antenna external to the 1.1 cm radius discharge tube. By comparing the predictions of a global equilibrium discharge model with the measured scalings of plasma density with RF power input and axial magnetic field strength, we demonstrate that inductive coupling (rather than capacitive coupling or wave damping) is the dominant energy transfer mechanism. Peak ion densities exceeding 5 × 10(19) m(-3) in argon gas at 30 mTorr have been achieved with and without a background field. Installation of the pre-ionization source on a magnetohydrodynamically driven jet experiment reduced the breakdown time and jitter and allowed for the creation of hotter, faster argon plasma jets than was previously possible.

  9. Battery-powered pulsed high density inductively coupled plasma source for pre-ionization in laboratory astrophysics experiments

    Science.gov (United States)

    Chaplin, Vernon H.; Bellan, Paul M.

    2015-07-01

    An electrically floating radiofrequency (RF) pre-ionization plasma source has been developed to enable neutral gas breakdown at lower pressures and to access new experimental regimes in the Caltech laboratory astrophysics experiments. The source uses a customized 13.56 MHz class D RF power amplifier that is powered by AA batteries, allowing it to safely float at 3-6 kV with the electrodes of the high voltage pulsed power experiments. The amplifier, which is capable of 3 kW output power in pulsed (<1 ms) operation, couples electrical energy to the plasma through an antenna external to the 1.1 cm radius discharge tube. By comparing the predictions of a global equilibrium discharge model with the measured scalings of plasma density with RF power input and axial magnetic field strength, we demonstrate that inductive coupling (rather than capacitive coupling or wave damping) is the dominant energy transfer mechanism. Peak ion densities exceeding 5 × 1019 m-3 in argon gas at 30 mTorr have been achieved with and without a background field. Installation of the pre-ionization source on a magnetohydrodynamically driven jet experiment reduced the breakdown time and jitter and allowed for the creation of hotter, faster argon plasma jets than was previously possible.

  10. Frequency-tuning radiofrequency plasma source operated in inductively-coupled mode under a low magnetic field

    Science.gov (United States)

    Takahashi, Kazunori; Nakano, Yudai; Ando, Akira

    2017-07-01

    A radiofrequency (rf) inductively-coupled plasma source is operated with a frequency-tuning impedance matching system, where the rf frequency is variable in the range of 20-50 MHz and the maximum power is 100 W. The source consists of a 45 mm-diameter pyrex glass tube wound by an rf antenna and a solenoid providing a magnetic field strength in the range of 0-200 Gauss. A reflected rf power for no plasma case is minimized at the frequency of ˜25 MHz, whereas the frequency giving the minimum reflection with the high density plasma is about 28 MHz, where the density jump is observed when minimizing the reflection. A high density argon plasma above 1× {{10}12} cm-3 is successfully obtained in the source for the rf power of 50-100 W, where it is observed that an external magnetic field of a few tens of Gauss yields the highest plasma density in the present configuration. The frequency-tuning plasma source is applied to a compact and high-speed silicon etcher in an Ar-SF6 plasma; then the etching rate of 8~μ m min-1 is obtained for no bias voltage to the silicon wafer, i.e. for the case that a physical ion etching process is eliminated.

  11. Rapid quantification of underivatized amino acids in plasma by hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass-spectrometry.

    Science.gov (United States)

    Prinsen, Hubertus C M T; Schiebergen-Bronkhorst, B G M; Roeleveld, M W; Jans, J J M; de Sain-van der Velden, M G M; Visser, G; van Hasselt, P M; Verhoeven-Duif, N M

    2016-09-01

    Amino acidopathies are a class of inborn errors of metabolism (IEM) that can be diagnosed by analysis of amino acids (AA) in plasma. Current strategies for AA analysis include cation exchange HPLC with post-column ninhydrin derivatization, GC-MS, and LC-MS/MS-related methods. Major drawbacks of the current methods are time-consuming procedures, derivative problems, problems with retention, and MS-sensitivity. The use of hydrophilic interaction liquid chromatography (HILIC) columns is an ideal separation mode for hydrophilic compounds like AA. Here we report a HILIC-method for analysis of 36 underivatized AA in plasma to detect defects in AA metabolism that overcomes the major drawbacks of other methods. A rapid, sensitive, and specific method was developed for the analysis of AA in plasma without derivatization using HILIC coupled with tandem mass-spectrometry (Xevo TQ, Waters). Excellent separation of 36 AA (24 quantitative/12 qualitative) in plasma was achieved on an Acquity BEH Amide column (2.1×100 mm, 1.7 μm) in a single MS run of 18 min. Plasma of patients with a known IEM in AA metabolism was analyzed and all patients were correctly identified. The reported method analyzes 36 AA in plasma within 18 min and provides baseline separation of isomeric AA such as leucine and isoleucine. No separation was obtained for isoleucine and allo-isoleucine. The method is applicable to study defects in AA metabolism in plasma.

  12. Numerical Coupling of the Particulate Phase to the Plasma Phase in Modeling of Multi-Arc Plasma Spraying

    International Nuclear Information System (INIS)

    Bobzin, K.; Öte, M.

    2017-01-01

    Inherent to Euler-Lagrange formulation, which can be used in order to describe the particle behavior in plasma spraying, particle in-flight characteristics are determined by calculating the impulse, heat and mass transfer between the plasma jet and individual powder particles. Based on the assumption that the influence of the particulate phase on the fluid phase is insignificant, impulse, heat and mass transfer from particles to the plasma jet can be neglected using the so-called numerical approach of “one-way coupling”. On the other hand, so-called “two-way coupling” considers the two-sided transfer between both phases. The former is a common simplification used in the literature to describe the plasma-particle interaction in thermal spraying. This study focuses on the significance of this simplification on the calculated results and shows that the use of this simplification leads to significant errors in calculated plasma and particle in-flight characteristics in three-cathode plasma spraying process. (paper)

  13. Diagnostic of capacitively coupled radio frequency plasma from electrical discharge characteristics: comparison with optical emission spectroscopy and fluid model simulation

    Science.gov (United States)

    Xiang, HE; Chong, LIU; Yachun, ZHANG; Jianping, CHEN; Yudong, CHEN; Xiaojun, ZENG; Bingyan, CHEN; Jiaxin, PANG; Yibing, WANG

    2018-02-01

    The capacitively coupled radio frequency (CCRF) plasma has been widely used in various fields. In some cases, it requires us to estimate the range of key plasma parameters simpler and quicker in order to understand the behavior in plasma. In this paper, a glass vacuum chamber and a pair of plate electrodes were designed and fabricated, using 13.56 MHz radio frequency (RF) discharge technology to ionize the working gas of Ar. This discharge was mathematically described with equivalent circuit model. The discharge voltage and current of the plasma were measured at different pressures and different powers. Based on the capacitively coupled homogeneous discharge model, the equivalent circuit and the analytical formula were established. The plasma density and temperature were calculated by using the equivalent impedance principle and energy balance equation. The experimental results show that when RF discharge power is 50–300 W and pressure is 25–250 Pa, the average electron temperature is about 1.7–2.1 eV and the average electron density is about 0.5 × 1017–3.6 × 1017 m‑3. Agreement was found when the results were compared to those given by optical emission spectroscopy and COMSOL simulation.

  14. The effect of magnetic field on bistability in 1D photonic crystal doped by magnetized plasma and coupled nonlinear defects

    International Nuclear Information System (INIS)

    Mehdian, H.; Mohammadzahery, Z.; Hasanbeigi, A.

    2014-01-01

    In this work, we study the defect mode and bistability behavior of 1-D photonic band gap structure with magnetized plasma and coupled nonlinear defects. The transfer matrix method has been employed to investigate the magnetic field effect on defect mode frequency and bistability threshold. The obtained results show that the frequency of defect mode and bistability threshold can be altered, without changing the structure of the photonic multilayer. Therefore, the bistability behavior of the subjected structure in the presence of magnetized plasma can be utilized in manufacturing wide frequency range devices

  15. Experimental control of the solvent load of inductively coupled argon plasmas and effects of the chloroform plasma load on their analytical performance

    Science.gov (United States)

    Maessen, F. J. M. J.; Kreuning, G.; Balke, J.

    The solvent plasma load ( QSPL) of water, methanol and chloroform was established as a function of the liquid uptake rate ( QL) by using a continuous weighing method for recording the rate differences between the relevant liquid streams. The shape of the QL vs QSPL curves revealed that the liquid uptake rate is a parameter much too insensitive to serve as a criterion for assessing the stability of "organic" plasmas. The quantity "maximum tolerable solvent plasma load" is suggested as a more useful criterion. Effects of rf power, observation height and solvent plasma load on the properties of chloroform inductively coupled plasmas (ICPs) are reported. The measurement of the axial distribution of net line intensities of representative spectral lines showed that the behaviour of emission lines as to their "hardness" is essentially the same in ICPs loaded with chloroform or water. The chloroform plasma load was regulated by the use of a condenser of which the temperature was varied in a range between -50°C and +20°C. Analytical performance characteristics such as net line and background intensities, signal-to-background ratios, and relative standard deviations of the background signal are presented for ICPs with various chloroform loads. Two sets of experimental conditions were finally selected for simultaneous multielement analysis of chloroform solvent solutions, one with and one without aerosol cooling. In the case that aerosol cooling was applied, the detection limits were similar to those for aqueous plasmas. Without aerosol cooling the detection limits were up to an order of magnitude poorer. An attempt has been made to catagorize organic solvents on the basis of both volatility and their behaviour in ICP systems. For a better understanding of the consequences of solvent volatility in ICP-AES it is of importance to consider separately the properties that determine the volatility of liquids, viz. the evaporation rate and the saturation vapour pressure.

  16. Measurements of energy distribution and thrust for microwave plasma coupling of electrical energy to hydrogen for propulsion

    Science.gov (United States)

    Morin, T.; Chapman, R.; Filpus, J.; Hawley, M.; Kerber, R.; Asmussen, J.; Nakanishi, S.

    1982-01-01

    A microwave plasma system for transfer of electrical energy to hydrogen flowing through the system has potential application for coupling energy to a flowing gas in the electrothermal propulsion concept. Experimental systems have been designed and built for determination of the energy inputs and outputs and thrust for the microwave coupling of energy to hydrogen. Results for experiments with pressure in the range 100 microns-6 torr, hydrogen flow rate up to 1000 micronmoles/s, and total absorbed power to 700 w are presented.

  17. Liquid sample introduction in inductively coupled plasma atomic emission and mass spectrometry — Critical review

    Energy Technology Data Exchange (ETDEWEB)

    Bings, N.H., E-mail: bings@uni-mainz.de; Orlandini von Niessen, J.O.; Schaper, J.N.

    2014-10-01

    Inductively coupled plasma optical emission spectroscopy (ICP-OES) and mass spectrometry (ICP-MS) can be considered as the most important tools in inorganic analytical chemistry. Huge progress has been made since the first analytical applications of the ICP. More stable RF generators, improved spectrometers and detection systems were designed along with the achievements gained from advanced microelectronics, leading to overall greatly improved analytical performance of such instruments. In contrast, for the vast majority of cases liquid sample introduction is still based on the pneumatic principle as described in the late 19th century. High flow pneumatic nebulizers typically demand the use of spray chambers as “aerosol filters” in order to match the prerequisites of an ICP. By this, only a small fraction of the nebulized sample actually contributes to the measured signal. Hence, the development of micronebulizers was brought forward. Those systems produce fine aerosols at low sample uptake rates, but they are even more prone for blocking or clogging than conventional systems in the case of solutions containing a significant amount of total dissolved solids (TDS). Despite the high number of publications devoted to liquid sample introduction, it is still considered the Achilles' heel of atomic spectrometry and it is well accepted, that the technology used for liquid sample introduction is still far from ideal, even when applying state-of-the-art systems. Therefore, this review is devoted to offer an update on developments in the field liquid sample introduction that had been reported until the year 2013. The most recent and noteworthy contributions to this field are discussed, trends are highlighted and future directions are outlined. The first part of this review provides a brief overview on theoretical considerations regarding conventional pneumatic nebulization, the fundamentals on aerosol generation and discusses characteristics of aerosols ideally

  18. Controlled Dissolution of Surface Layers for Elemental Analysis by Inductively Coupled Plasma-Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lorge, Susan Elizabeth [Iowa State Univ., Ames, IA (United States)

    2007-01-01

    Determining the composition of thin layers is increasingly important for a variety of industrial materials such as adhesives, coatings and microelectronics. Secondary ion mass spectrometry (SIMS), Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), glow discharge optical emission spectroscopy (GDOES), glow discharge mass spectrometry (GDMS), and laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) are some of the techniques that are currently employed for the direct analysis of the sample surface. Although these techniques do not suffer from the contamination problems that often plague sample dissolution studies, they do require matrix matched standards for quantification. Often, these standards are not readily available. Despite the costs of clean hoods, Teflon pipette tips and bottles, and pure acids, partial sample dissolution is the primary method used in the semiconductor industry to quantify surface impurities. Specifically, vapor phase decomposition (VPD) coupled to ICP-MS or total reflection x-ray fluorescence (TXRF) provides elemental information from the top most surface layers at detection sensitivities in the 107-1010atoms/cm2 range. The ability to quantify with standard solutions is a main advantage of these techniques. Li and Houk applied a VPD-like technique to steel. The signal ratio of trace element to matrix element was used for quantification. Although controlled dissolution concentrations determined for some of the dissolved elements agreed with the certified values, concentrations determined for refractory elements (Ti, Nb and Ta) were too low. LA-ICP-MS and scanning electron microscopy (SEM) measurements indicated that carbide grains distributed throughout the matrix were high in these refractory elements. These elements dissolved at a slower rate than the matrix element, Fe. If the analyte element is not removed at a rate similar to the matrix element a true

  19. Inductively coupled plasma mass spectrometer installation modifications in a radioactive contaminated laboratory for the analysis of DOE radioactive waste streams

    International Nuclear Information System (INIS)

    Giaquinto, J.M.; Keller, J.M.; Meeks, A.M.

    1997-04-01

    The operation and maintenance of a complex analytical instrument such as an inductively coupled plasma mass spectrometer in a radioactive contaminated environment presents unique problems and challenges that have to be considered in the purchasing and installation process. Considerations such as vendor experience, typical radiation levels, sample matrices encountered during sample analysis, instrument accessibility for maintenance, and upkeep must be incorporated into the decision process. The Radioactive Materials Analytical Laboratory (RMAL) at Oak Ridge National Laboratory (ORNL) recently purchased and installed an inductively coupled plasma mass spectrometer for the analysis of Department of Energy (DOE) radioactive waste streams. This presentation will outline the purchasing decision, installation of the instrument, and how the modifications needed to operate in a radioactive contaminated laboratory do not significantly impact the daily operation and maintenance requirements of the instrument. Also, a contamination survey of the system will be presented which demonstrates the contamination levels in the instrument from the sample introduction system to the detector

  20. Inductively coupled plasma mass spectrometer installation modifications in a radioactive contaminated laboratory for the analysis of DOE radioactive waste streams

    International Nuclear Information System (INIS)

    Giaquinto, J.M.; Keller, J.M.; Meeks, A.M.

    1998-01-01

    The operation and maintenance of a complex analytical instrument such as an inductively coupled plasma mass spectrometer in a radioactive contaminated environment presents unique problems and challenges that have to be considered in the purchasing and installation process. Considerations such as vendor experience, typical radiation levels, sample matrices encountered during sample analysis, instrument accessibility for maintenance, and upkeep must be incorporated into the decision process. The Radioactive Materials Analytical Laboratory (RMAL) at Oak Ridge National Laboratory (ORNL) recently purchased and installed an inductively coupled plasma mass spectrometer for the analysis of Department of Energy (DOE) radioactive waste streams. This presentation will outline the purchasing decision, installation of the instrument, and how the modifications needed to operate in a radioactive contaminated laboratory do not significantly impact the daily operation and maintenance requirements of the instrument. Also, a contamination survey of the system will be presented which demonstrates the contamination levels in the instrument from the sample introduction system to the detector. (author)

  1. Experimental characterization of a strongly coupled solid density plasma generated in a short-pulse laser target interaction

    International Nuclear Information System (INIS)

    Gregori, G.; Hansen, S.B.; Key, M.H.; King, J.; Mackinnon, A.J.; Park, H.; Patel, P.K.; Shepard, R.; Snavely, R.A.; Wilks, S.C.; Glenzer, S.H.

    2005-01-01

    We have measured high resolution copper Kα spectra from a picosecond high intensity laser produced plasma. By fitting the shape of the experimental spectra with a self-consistent-field model which includes all the relevant line shifts from multiply ionized atoms, we are able to infer time and spatially averaged electron temperatures (T e ) and ionization state (Z) in the foil. Our results show increasing values for T e and Z when the overall mass of the target is reduced. In particular, we measure temperatures in excess of 200 eV with Z ∼ 13-14. For these conditions the ion-ion coupling constant is Λ ii ∼ 8-9, thus suggesting the achievement of a strongly coupled plasma regime

  2. Matrix separation by chelation to prepare biological materials for isotopic zinc analysis by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Durrant, S.F.; Krushevska, A.; Amarasiriwardena, D.; Argentine, M.D.; Romon-Guesnier, S.; Barnes, R.M.

    1994-01-01

    Following an evaluation of three chelating resins [Chelex-100, poly(dithiocarbamate) (PDTC) and carboxymethylated poly(ethyleneimine)-poly(methylenepolyphenylene) isocyanate (CPPI)], a procedure was established with the last of these for the separation of Zn from biological matrix elements prior to 70 Zn: 68 Zn isotopic analysis by inductively coupled plasma mass spectrometry (ICP-MS). The method was verified by establishing Zn recoveries and by determining its effectiveness in removing Cl and Na from buffered test solutions. Calcium, Na, and Zn concentration data were determined by inductively coupled plasma atomic emission spectrometry. Chlorine was measured by electrothermal vaporization ICP-MS. The efficacy of the technique was demonstrated by the determination of zinc isotope ratios in bovine milk and human urine. (Author)

  3. Slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry for steelmaking flue dust analysis

    Science.gov (United States)

    Coedo, A. G.; Dorado, T.; Padilla, I.; Maibusch, R.; Kuss, H.-M.

    2000-02-01

    A commercial atomic absorption graphite furnace (AAGF), with a self-made adapter and valve system, was used as a slurry sampling cell for electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). The system was applied to the determination of As, Sn, Sb, Se, Te, Bi, Cd, V, Ti and Mo in steelmaking flue dusts. Experimental conditions with respect to ETV and ICP-MS operating parameters were optimized. Compared to aqueous solutions, slurry samples were found to present better analyte transport. Microgram amounts of Rh were used to reduce the difference in analyte response in sensitivity for aqueous solutions of the tested analytes. No such increasing effect was observed for slurry samples and aqueous standards. An added quantity of Rh acting as modifier/carrier resulted in an increase for the same analytes in matrix-slurry solutions, even the addition of an extra Rh quantity has resulted in a decrease in the signals. The effect of Triton X-100 (used as a dispersant agent) on analyte intensity and precision was also studied. External calibration from aqueous standards spiked with 100 μg ml -1 Rh was performed to quantified 0.010 g/100 ml slurry samples. Results are presented for a certified reference electrical arc furnace flue dust (EAF): CRM-876-1 (Bureau of Analysis Samples Ltd., Cleveland, UK), a reference sample of coke ashes X-3705 (from AG der Dillinger Hüttenwerke, Germany), and a representative sample of EAF flue dust from a Spanish steelmaking company (CENIM-1). For the two reference materials an acceptable agreement with certificate values was achieved, and the results for the CENIM sample matched with those obtained from conventional nebulization solution.

  4. Inductively coupled plasma etch damage in (-201) Ga2O3 Schottky diodes

    Science.gov (United States)

    Yang, Jiancheng; Ahn, Shihyun; Ren, F.; Khanna, Rohit; Bevlin, Kristen; Geerpuram, Dwarakanath; Pearton, S. J.; Kuramata, A.

    2017-04-01

    Bulk, single-crystal Ga2O3 was etched in BCl3/Ar inductively coupled plasmas as a function of ion impact energy. For pure Ar, the etch rate (R) was found to increase with ion energy (E) as predicted from a model of ion enhanced sputtering by a collision-cascade process, R ∝(E0.5 - ETH0.5), where the threshold energy for Ga2O3, ETH, was experimentally determined to be ˜75 eV. When BCl3 was added, the complexity of the ion energy distribution precluded, obtaining an equivalent threshold. Electrically active damage introduced during etching was quantified using Schottky barrier height and diode ideality factor measurements obtained by evaporating Ni/Au rectifying contacts through stencil masks onto the etched surfaces. For low etch rate conditions (˜120 Å min-1) at low powers (150 W of the 2 MHz ICP source power and 15 W rf of 13.56 MHz chuck power), there was only a small decrease in reverse breakdown voltage (˜6%), while the barrier height decreased from 1.2 eV to 1.01 eV and the ideality factor increased from 1.00 to 1.06. Under higher etch rate (˜700 Å min-1) and power (400 W ICP and 200 W rf) conditions, the damage was more significant, with the reverse breakdown voltage decreasing by ˜35%, the barrier height was reduced to 0.86 eV, and the ideality factor increased to 1.2. This shows that there is a trade-off between the etch rate and near-surface damage.

  5. Determination of total tin in canned food using inductively coupled plasma atomic emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Perring, Loic; Basic-Dvorzak, Marija [Department of Quality and Safety Assurance, Nestle Research Centre, P.O. Box 44, Vers chez-les-Blanc, 1000, Lausanne (Switzerland)

    2002-09-01

    Tin is considered to be a priority contaminant by the Codex Alimentarius Commission. Tin can enter foods either from natural sources, environmental pollution, packaging material or pesticides. Higher concentrations are found in processed food and canned foods. Dissolution of the tinplate depends on the of food matrix, acidity, presence of oxidising reagents (anthocyanin, nitrate, iron and copper) presence of air (oxygen) in the headspace, time and storage temperature. To reduce corrosion and dissolution of tin, nowadays cans are usually lacquered, which gives a marked reduction of tin migration into the food product. Due to the lack of modern validated published methods for food products, an ICP-AES (Inductively coupled plasma-atomic emission spectroscopy) method has been developed and evaluated. This technique is available in many laboratories in the food industry and is more sensitive than atomic absorption. Conditions of sample preparation and spectroscopic parameters for tin measurement by axial ICP-AES were investigated for their ruggedness. Two methods of preparation involving high-pressure ashing or microwave digestion in volumetric flasks were evaluated. They gave complete recovery of tin with similar accuracy and precision. Recoveries of tin from spiked products with two levels of tin were in the range 99{+-}5%. Robust relative repeatabilities and intermediate reproducibilities were <5% for different food matrices containing >30 mg/kg of tin. Internal standard correction (indium or strontium) did not improve the method performance. Three emission lines for tin were tested (189.927, 283.998 and 235.485 nm) but only 189.927 nm was found to be robust enough with respect to interferences, especially at low tin concentrations. The LOQ (limit of quantification) was around 0.8 mg/kg at 189.927 nm. A survey of tin content in a range of canned foods is given. (orig.)

  6. Analysis of Trace Elements in Rat Bronchoalveolar Lavage Fluid by Inductively Coupled Plasma Mass Spectrometry.

    Science.gov (United States)

    Qamar, Wajhul; Al-Ghadeer, Abdul Rahman; Ali, Raisuddin; Abuelizz, Hatem A

    2017-08-01

    The main objective was to determine the elemental profile of the lung lining fluid of rats which are used as model animals in various experiments. Lung lining fluid elemental constitution obtained after bronchoalveolar lavage fluid (BALF) was analyzed by inductively coupled plasma mass spectrometry (ICP-MS) to determine the biological trace elements along with calcium and magnesium. BALF was collected from healthy rats using a tracheal cannula. However, cells in BALF were counted to monitor any underlying inflammatory lung condition. Cell free BALF samples were processed and analyzed for the elements including magnesium (Mg), calcium (Ca), chromium (Cr), manganese (Mn), iron (Fe), nickel (Ni), copper (Cu), zinc (Zn), selenium (Se), bromine (Br), and iodine (I). In view of this, calcium concentration was the highest (6318.08 ± 3094.3 μg/L) and copper concentration was the lowest (0.89 ± 0.21 μg/L). The detected elements, from high to low concentration, include Ca > Mg > Fe > Br > I > Cr > Ni > Zn > Mn > Se > Cu. Pearson's correlation analysis revealed no significant correlation between cell count and concentration of any of the element detected in BALF. Correlation analysis also revealed significant positive correlation among Fe, I, Cr, Ni, and Mn. Ca was found to be correlated negatively with Cu and positively with Se. Br and Mg found to be positively correlated with each other. Zn remained the only element that was not found to be correlated with any of the elements in the rat BALF.

  7. Measurements of β or α emitter long lived radionuclides using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Provitina, O.

    1993-01-01

    The measurement of long-lived radionuclides is highly important for characterizing nuclear wastes for their later storage. The main techniques for characterizing these isotopes are α spectrometry, β counting and γ spectrometry. The large period of these isotopes leads to low specific activity needing time consuming measurements in order to obtain significant signals. Moreover, the radiometric techniques are often limited by problems of interferences involving several steps of pretreatments. Among these steps, the specific extraction with crown ethers is highly selective for the separation of 99 Tc, 129 I and 135 Cs particularly. The radiometric techniques are here replaced by inductively coupled plasma mass spectroscopy (ICP-MS) the advantages of which are: few interferences, sensitivity which does not depend on the radiologic period as compared to radiochemistry. ICP-MS can then measure 237 Np in enriched uranium matrix and thereby reduce by a factor of 4 the sample pretreatment and the duration of the analysis usually performed by α spectrometry. Another technique, electrothermal vaporization (ETV), is consequently used. Crown ether extraction-ETV-ICP-MS is employed for measuring the long lived radionuclides 99 Tc and 129 I. The conditions of the extraction and the parameters of the ETV and the ICP-MS are studied and optimized. The methods optimized (extraction, electrothermal vaporization) are validated in the case of 99 Tc, in real samples. The spike method is required to quantify technetium, the quantification with calibration leading to bad results. The results obtained are in good agreement with the expected values. Extraction of technetium on anionic resin and its measurement by the spike method with pneumatic nebulization-ICP-MS is also performed on other samples. Measured values are also in agreement with expected values, but the method of extraction is more time consuming (half a day) than the extraction with crown ether (one hour). (author). 54 figs

  8. Determination of Mercury in Aerosol by Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hofer Iris

    2017-12-01

    Full Text Available Based on the knowledge gained from published studies, a new analytical method has been developed for the quantification of mercury (Hg in the gas-vapor phase of mainstream cigarette smoke and in heated tobacco aerosol generated by a tobacco heating system (THS using Inductively Coupled Plasma Mass Spectrometry (ICP-MS. From a preliminary test, the mercury concentration in the particulate matter of mainstream smoke from Kentucky reference cigarettes 3R4F generated under the International Organization for Standardization (ISO smoking regimen was compared with the mercury concentration in the gasvapor phase to assure that mercury is only measurable in the gas-vapor phase, as reported in an earlier published study. The particulate matter was collected using an electrostatic precipitation trap and was analyzed by ICP-MS after a mineralization step. The gas-vapor phase was trapped in the same smoking run as for the particulate matter using two impingers containing a nitric acid-hydrochloric acid-gold solution. The impingers were connected in series behind the electrostatic precipitation trap and the combined impinger solution was analyzed by ICP-MS after sample dilution without further sample treatment. The addition of gold has shown to be efficient for maintaining mercury in an ionized form in the impinger solution and to minimize the mercury memory effect in the sample introduction system of the ICP-MS. Only mercury in the gas-vapor phase could be quantified whereas the signal for mercury in the particulate matter was found close to those of blank solutions and was not measurable, as already mentioned in an earlier study. Following this preliminary test, the electrostatic precipitation trap was replaced by a Cambridge filter pad for the separation of the gas-vapor phase from the particulate matter where only mercury in the gas-vapor phase was quantified.

  9. Characteristics of an ion funnel as ion guide in an inductively coupled plasma mass spectrometer

    International Nuclear Information System (INIS)

    Egorova, Tatiana; Dietiker, Rolf; Hattendorf, Bodo; Günther, Detlef

    2012-01-01

    The characteristics of an electrodynamic ion funnel as an alternative ion optics element for inductively coupled plasma mass spectrometry (ICPMS) were investigated in this work. Therefore the ion lens of a conventional ICPMS system has been removed and a custom made ion funnel was installed instead. The effects of the radiofrequency-amplitude and frequency and the axial funnel potential on the ion transmission have been investigated for different configurations. Under optimum conditions the ion current was in average 10-fold lower than with the un-modified instrument, while CeO + /Ce + ratios increased ten-fold. Nonetheless, confinement of atomic ions from the ICP inside the ion funnel could be achieved by optimizing radiofrequency and DC potentials at the funnel electrodes as indicated by an increase in the ion signal intensities relative to the field-free case. With the ion funnel being partially enclosed, gases, such as N 2 and H 2 , could be introduced which can reduce the abundance of Ar + and Ar-based polyatomic ions by one (H 2 ) to three (N 2 ) orders of magnitude. Based on these experiments, however H 2 would be more favorable since it did not affect the transmission of low m/z analyte ions to a great extent. - Highlights: ► An electrodynamic ion funnel was inserted in the vacuum interface of an ICPMS. ► Ion transmission was investigated in dependence on operating parameters. ► The influence on mass resolving power was studied. ► Atomic ions with low mass (< 100 m/z) can be guided by the funnel.

  10. Copper Determination in Gunshot Residue by Cyclic Voltammetric and Inductive Coupled Plasma-Optical Emission Spectroscopy

    Directory of Open Access Journals (Sweden)

    Mohd Hashim Nurul’Afiqah Hashimah

    2016-01-01

    Full Text Available Analysis of gunshot residue (GSR is a crucial evidences for a forensic analyst in the fastest way. GSR analysis insists a suitable method provides a relatively simple, rapid and precise information on the spot at the crime scene. Therefore, the analysis of Cu(II in GSR using cyclic voltammetry (CV on screen printed carbon electrode (SPCE is a better choice compared to previous alternative methods such as Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES those required a long time for analysis. SPCE is specially designed to handle with microvolumes of sample such as GSR sample. It gives advantages for identification of copper in GSR on-site preliminary test to prevent the sample loss on the process to be analyzed in the laboratory. SPCE was swabbed directly on the shooter’s arm immediately after firing and acetate buffer was dropped on SPCE before CV analysis. For ICP-OES analysis, cotton that had been soaked in 0.5 M nitric acid was swabbed on the shooter’s arm immediately after firing and kept in a tightly closed sampling tube. Gold coated SPCE that had been through nanoparticles modification exhibits excellent performance on voltammograms. The calibration was linear from 1 to 50 ppm of copper, the limit of detection for copper was 0.3 ppm and a relative standard deviation was 6.1 %. The method was successfully applied to the determination of copper in GSR. The Cu determination on SPCE was compared and validated by ICP-OES method with 94 % accuracy.

  11. Evaporation preconcentration of trace elements in rainwater for inductively coupled plasma emission spectrometry

    International Nuclear Information System (INIS)

    Nishikawa, Masataka; Ambe, Yoshinari; Mizoguchi, Tsuguo

    1985-01-01

    An evaporation preconcentration of rainwater sample was studied for the analysis of trace elements by inductively coupled plasma emission spectrometry (ICP-AES). The evaporation preconcentration procedure is favorable for multi-elements analysis by ICP-AES because most of the elements, except for mercury and other volatile ones, can be enriched simultaneously. A conventional type of rotary evaporator was reformed setting a newly designed sample vessel made of teflon inside the glass bottle which can be separated into two parts, and compared to the former type of evaporator having a vessel made of hard glass. From the experiments using twice distilled water it was found that small amount of B, Na, Mg, Si, and Ca dissolved out from the surface of the glass vessel giving some positive error. From the teflon vessel, however, no contamination of elements was detected. When removing the cotent from the vessel into a measuring cylinder, adhesion of tiny amount of concentrated sample water occurred on the surface of the vessel to cause an error in the calculation of the enrichment factor. It was found that the volume of the adhered solution on the surface of a glass flask was nearly constant (0.5 ml) independently of the volume of the solution under this conditions, and using this value the correction of the result was possible. Such an adhesion, on the other hand, was not observed for the case of teflon vessel within the accuracy of our experiments. In conculusion, although the improved rotary evaporator with a teflon vessel is not more time-saving than a conventional glass evaporator, it is more advantageous in the following items; (1) No dissolution of element from the surface of the cocentration vessel; (2) High efficiency in preconcentration of rain samples (1000 ml to 1 ml); (3) No backward flow of condensed water on the glass part of the evaporator into the teflon vessel. (author)

  12. Elemental analysis using instrumental neutron activation analysis and inductively coupled plasma atomic emission spectrometry: a comparative study

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Choi, Kwang Soon; Moon, Jong Hwa; Kim, Sun Ha; Lim, Jong Myoung; Kim, Young Jin; Quraishi, Shamshad Begum

    2003-05-01

    Elemental analyses for certified reference materials were carried out using instrumental neutron activation analysis and inductively coupled plasma-atomic emission spectrometry. Five Certified Reference Materials (CRM) were selected for the study on comparative analysis of environmental samples. The CRM are Soil (NIST SRM 2709), Coal fly ash (NIST SRM 1633a), urban dust (NIST SRM 1649a) and air particulate on filter media (NIST SRM 2783 and human hair (GBW 09101)

  13. GaAs/AlGaAs ridge lasers with etched mirrors formed by an inductively coupled plasma reactor

    Science.gov (United States)

    Horst, S. C.; Agarwala, S.; King, O.; Fitz, J. L.; Smith, S. D.

    1997-09-01

    Etched mirrors for semiconductor lasers are necessary for optoelectronic integrated circuit applications. This letter reports on the use of an inductively coupled plasma (ICP) reactor to create etched mirrors on GaAs/AlGaAs ridge lasers. Etch chemistries consisting of boron trichloride and chlorine were used to achieve both smooth and vertical mirror surfaces. Optical measurements indicate that devices fabricated with ICP etched mirrors are comparable to devices formed by cleaved mirrors.

  14. Determination of trace and ultra-trace elements in Dergaon meteorite by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Balaram, V.; Gnaneswara Rao, T.; Anjaiah, K.V.; Phukon, N.; Majumdar, A.C.

    2003-01-01

    In this paper, a detailed methodology for high precision measurement of several trace and ultra-trace elements including REE and PGE have been presented using effective sample preparation techniques and inductively coupled plasma mass spectrometry. Discussion is focussed on aspects, such as total dissolution and recovery of all elements, minimization of oxide and doubly-charged and other polyatomic ion interferences, calibration by matrix matching standards, accuracy and precision

  15. Analysis of inter-country input-output table based on bibliographic coupling network: How industrial sectors on the GVC compete for production resources

    Science.gov (United States)

    Guan, Jun; Xu, Xiaoyu; Xing, Lizhi

    2018-03-01

    The input-output table is comprehensive and detailed in describing national economic systems with abundance of economic relationships depicting information of supply and demand among industrial sectors. This paper focuses on how to quantify the degree of competition on the global value chain (GVC) from the perspective of econophysics. Global Industrial Strongest Relevant Network models are established by extracting the strongest and most immediate industrial relevance in the global economic system with inter-country input-output (ICIO) tables and then have them transformed into Global Industrial Resource Competition Network models to analyze the competitive relationships based on bibliographic coupling approach. Three indicators well suited for the weighted and undirected networks with self-loops are introduced here, including unit weight for competitive power, disparity in the weight for competitive amplitude and weighted clustering coefficient for competitive intensity. Finally, these models and indicators were further applied empirically to analyze the function of industrial sectors on the basis of the latest World Input-Output Database (WIOD) in order to reveal inter-sector competitive status during the economic globalization.

  16. Enhancement of the c-axis texture of aluminum nitride by an inductively coupled plasma reactive sputtering process

    International Nuclear Information System (INIS)

    Yeh, C.-M.; Chen, C.H.; Gan, J.-Y.; Kou, C.S.; Hwang, J.

    2005-01-01

    Inductively coupled plasma reactive sputtering technique has been applied to grow highly oriented aluminum nitride on Si(111) at high process pressure. An inductive coil of 3 and 1/4 turns was introduced to generate a plasma zone near the substrate holder, which provides additional energy to the radicals inside the plasma zone. The full width at half-maximum of the X-ray rocking curve of AlN(0002) is reduced from 7.90 deg. to 4.05 deg. when the inductive coil power is raised from 0 to 180 W. The enhancement of the c-axis texture of AlN is attributed to the increase of the density of the sputtered Al atoms of high energy

  17. Formation Of Carbon Oxides In CH4/O2 Plasmas Produced By Inductively Coupled RF Discharges At Low Pressure

    International Nuclear Information System (INIS)

    Moeller, Ivonne; Soltwisch, Henning

    2003-01-01

    The formation of CO and CO2 has been studied in inductively coupled rf (13.56 MHz) discharges with varied mixtures of CH4 and O2 as feed gases at a total pressure of 10 Pa, flow rates of <10 sccm, and input powers of <500 W. The primary diagnostic tool has been TDLAS (tunable diode laser absorption spectroscopy) to measure absolute concentrations of molecular species as well as their kinetic and rovibrational temperatures. Of particular interest is the sudden transition between different modes of power coupling (capacitive and inductive mode, resp.) and the related changes of the plasma composition. We have found that the power threshold for this transition exhibits a clear hysteresis and depends on the oxygen content. Comparing the ratio of the CO- and CO2-concentrations in capacitive mode with corresponding data from a parallel-plate discharge, clear differences have been observed. The findings can partly be explained on the basis of plasma-chemical reaction chains using tabulated cross-sections in combination with estimations of the electron energy distribution function. Some observations (as, e.g. the presence of CO in inductively coupled plasmas that are fed by pure oxygen) cannot be understood from volume reactions only but point to an important role of surface processes, which depend on the materials of the discharge chamber and on its history and cleaning method

  18. The characterization of plasma-surface interactions using the inductively coupled gaseous electronics conference reference cell platform

    Science.gov (United States)

    Joseph, Eric Andrew

    rates and sample surface chemistry of a hybrid polydimethylsiloxane material. Depending on the percentage of oxygen admixed in the tetrafluoromethane feedgas, the etch could be tailored from energy dependent to energy independent. Tweaking the process in an inductively coupled plasma further improved the etch rate such that it was twice as high as those published in a capacitive plasma process. The resultant stoichiometry of the etched films was also found to depend on the feedgas chemistry as the refractive index of the material increased by 7% when pure oxygen was used and decreased by 6% when pure tetrafluoromethane was used. (Abstract shortened by UMI.)

  19. Study on the RF inductively coupled plasma spheroidization of refractory W and W-Ta alloy powders

    Science.gov (United States)

    Chenfan, YU; Xin, ZHOU; Dianzheng, WANG; Neuyen VAN, LINH; Wei, LIU

    2018-01-01

    Spherical powders with good flowability and high stacking density are mandatory for powder bed additive manufacturing. Nevertheless, the preparation of spherical refractory tungsten and tungsten alloy powders is a formidable task. In this paper, spherical refractory metal powders processed by high-energy stir ball milling and RF inductively coupled plasma were investigated. By utilizing the technical route, pure spherical tungsten powders were prepared successfully, the flowability increased from 10.7 s/50 g to 5.5 s/50 g and apparent density increased from 6.916 g cm‑3 to 11.041 g cm‑3. Alloying element tantalum can reduce the tendency to micro-crack during tungsten laser melting and rapid solidification process. Spherical W-6Ta (%wt) powders were prepared in this way, homogeneous dispersion of tantalum in a tungsten matrix occurred but a small amount of flake-like shape particles appeared after high-energy stir ball milling. The flake-like shape particles can hardly be spheroidized in subsequent RF inductively coupled plasma process, might result from the unique suspended state of flaky particles under complex electric and magnetic fields as well as plasma-particle heat exchange was different under various turbulence models. As a result, the flake-like shape particles cannot pass through the high-temperature area of thermal plasma torch and cannot be spheroidized properly.

  20. Comparative analysis of barium titanate thin films dry etching using inductively coupled plasmas by different fluorine-based mixture gas.

    Science.gov (United States)

    Li, Yang; Wang, Cong; Yao, Zhao; Kim, Hong-Ki; Kim, Nam-Young

    2014-01-01

    In this work, the inductively coupled plasma etching technique was applied to etch the barium titanate thin film. A comparative study of etch characteristics of the barium titanate thin film has been investigated in fluorine-based (CF4/O2, C4F8/O2 and SF6/O2) plasmas. The etch rates were measured using focused ion beam in order to ensure the accuracy of measurement. The surface morphology of etched barium titanate thin film was characterized by atomic force microscope. The chemical state of the etched surfaces was investigated by X-ray photoelectron spectroscopy. According to the experimental result, we monitored that a higher barium titanate thin film etch rate was achieved with SF6/O2 due to minimum amount of necessary ion energy and its higher volatility of etching byproducts as compared with CF4/O2 and C4F8/O2. Low-volatile C-F compound etching byproducts from C4F8/O2 were observed on the etched surface and resulted in the reduction of etch rate. As a result, the barium titanate films can be effectively etched by the plasma with the composition of SF6/O2, which has an etch rate of over than 46.7 nm/min at RF power/inductively coupled plasma (ICP) power of 150/1,000 W under gas pressure of 7.5 mTorr with a better surface morphology.

  1. Gauge/gravity duality, jets in strongly coupled plasma, and far-from-equilibrium dynamics in conformal field theories

    Science.gov (United States)

    Chesler, Paul M.

    We study dynamics in conformal field theories with gravitational duals. Attention is focused on heavy and light quark jets as well as far-from-equilibrium dynamics. The stress-energy tensor of a heavy quark moving through a strongly coupled N = 4 supersymmetric Yang-Mills plasma is evaluated using gauge/gravity duality. The accuracy with which the resulting wake, in position space, is reproduced by hydrodynamics is examined. Remarkable agreement is found between hydrodynamics and the complete result down to distances less than 2/ T away from the quark. We also compute the penetration depth of a light quark moving through a N = 4 supersymmetric Yang-Mills plasma using a combination of analytic and numerical techniques. We find that the maximum distance a quark with energy E can travel through a plasma is given by Dxmax E= C/T E/Tl 1/3 with C ≈ 0.5. For the study of dynamics far-from-equilibrium, we consider the creation and evolution of boost invariant anisotropic, strongly coupled conformal plasma. In the dual gravitational description, this corresponds to horizon formation in a geometry driven to be anisotropic by a time-dependent change in boundary conditions.

  2. The influence of laser-particle interaction in laser induced breakdown spectroscopy and laser ablation inductively coupled plasma spectrometry

    Science.gov (United States)

    Lindner, Helmut; Loper, Kristofer H.; Hahn, David W.; Niemax, Kay

    2011-02-01

    Particles produced by previous laser shots may have significant influence on the analytical signal in laser-induced breakdown spectroscopy (LIBS) and laser ablation inductively coupled plasma (LA-ICP) spectrometry if they remain close to the position of laser sampling. The effects of these particles on the laser-induced breakdown event are demonstrated in several ways. LIBS-experiments were conducted in an ablation cell at atmospheric conditions in argon or air applying a dual-pulse arrangement with orthogonal pre-pulse, i.e., plasma breakdown in a gas generated by a focussed laser beam parallel and close to the sample surface followed by a delayed crossing laser pulse in orthogonal direction which actually ablates material from the sample and produces the LIBS plasma. The optical emission of the LIBS plasma as well as the absorption of the pre-pulse laser was measured. In the presence of particles in the focus of the pre-pulse laser, the plasma breakdown is affected and more energy of the pre-pulse laser is absorbed than without particles. As a result, the analyte line emission from the LIBS plasma of the second laser is enhanced. It is assumed that the enhancement is not only due to an increase of mass ablated by the second laser but also to better atomization and excitation conditions favored by a reduced gas density in the pre-pulse plasma. Higher laser pulse frequencies increase the probability of particle-laser interaction and, therefore, reduce the shot-to-shot line intensity variation as compared to lower particle loadings in the cell. Additional experiments using an aerosol chamber were performed to further quantify the laser absorption by the plasma in dependence on time both with and without the presence of particles. The overall implication of laser-particle interactions for LIBS and LA-ICP-MS/OES are discussed.

  3. Inductively Coupled Plasma-Induced Electrical Damage on HgCdTe Etched Surface at Cryogenic Temperatures

    Science.gov (United States)

    Liu, L. F.; Chen, Y. Y.; Ye, Z. H.; Hu, X. N.; Ding, R. J.; He, L.

    2018-03-01

    Plasma etching is a powerful technique for transferring high-resolution lithographic patterns into HgCdTe material with low etch-induced damage, and it is important for fabricating small-pixel-size HgCdTe infrared focal plane array (IRFPA) detectors. P- to n-type conversion is known to occur during plasma etching of vacancy-doped HgCdTe; however, it is usually unwanted and its removal requires extra steps. Etching at cryogenic temperatures can reduce the etch-induced type conversion depth in HgCdTe via the electrical damage mechanism. Laser beam-induced current (LBIC) is a nondestructive photoelectric characterization technique which can provide information regarding the vertical and lateral electrical field distribution, such as defects and p-n junctions. In this work, inductively coupled plasma (ICP) etching of HgCdTe was implemented at cryogenic temperatures. For an Ar/CH4 (30:1 in SCCM) plasma with ICP input power of 1000 W and RF-coupled DC bias of ˜ 25 V, a HgCdTe sample was dry-etched at 123 K for 5 min using ICP. The sample was then processed to remove a thin layer of the plasma-etched region while maintaining a ladder-like damaged layer by continuously controlling the wet chemical etching time. Combining the ladder etching method and LBIC measurement, the ICP etching-induced electrical damage depth was measured and estimated to be about 20 nm. The results indicate that ICP etching at cryogenic temperatures can significantly suppress plasma etching-induced electrical damage, which is beneficial for defining HgCdTe mesa arrays.

  4. Consideration of the Role of Plasma in a Plasma-Coupled Selective Catalytic Reduction of Nitrogen Oxides with a Hydrocarbon Reducing Agent

    Directory of Open Access Journals (Sweden)

    Byeong Ju Lee

    2017-10-01

    Full Text Available The purpose of this study is to explain how plasma improves the performance of selective catalytic reduction (SCR of nitrogen oxides (NOx with a hydrocarbon reducing agent. In the plasma-coupled SCR process, NOx reduction was performed with n-heptane as a reducing agent over Ag/γ-Al2O3 as a catalyst. We found that the plasma decomposes n-heptane into several oxygen-containing products such as acetaldehyde, propionaldehyde and butyraldehyde, which are more reactive than the parent molecule n-heptane in the SCR process. Separate sets of experiments using acetaldehyde, propionaldehyde and butyraldehyde, one by one, as a reductant in the absence of plasma, have clearly shown that the presence of these partially oxidized compounds greatly enhanced the NOx conversion. The higher the discharge voltage, the more the amounts of such partially oxidized products. The oxidative species produced by the plasma easily converted NO into NO2, but the increase of the NO2 fraction was found to decrease the NOx conversion. Consequently, it can be concluded that the main role of plasma in the SCR process is to produce partially oxidized compounds (aldehydes, having better reducing power. The catalyst-alone NOx removal efficiency with n-heptane at 250 °C was measured to be less than 8%, but it increased to 99% in the presence of acetaldehyde at the same temperature. The NOx removal efficiency with the aldehyde reducing agent was higher as the number of carbons in the aldehyde was more; for example, the NOx removal efficiencies at 200 °C with butyraldehyde, propionaldehyde and acetaldehyde were measured to be 83.5%, 58.0% and 61.5%, respectively, which were far above the value (3% obtained with n-heptane.

  5. Fingerprinting the extended Higgs sector using one-loop corrected Higgs boson couplings and future precision measurements

    Directory of Open Access Journals (Sweden)

    Shinya Kanemura

    2015-07-01

    Full Text Available We calculate radiative corrections to a full set of coupling constants for the 125 GeV Higgs boson at the one-loop level in two Higgs doublet models with four types of Yukawa interaction under the softly-broken discrete Z2 symmetry. The renormalization calculations are performed in the on-shell scheme, in which the gauge dependence in the mixing parameter which appears in the previous calculation is consistently avoided. We first show the details of our renormalization scheme, and present the complete set of the analytic formulae of the renormalized couplings. We then numerically demonstrate how the inner parameters of the model can be extracted by the future precision measurements of these couplings at the high luminosity LHC and the International Linear Collider.

  6. Code Coupling via Jacobian-Free Newton-Krylov Algorithms with Application to Magnetized Fluid Plasma and Kinetic Neutral Models

    Energy Technology Data Exchange (ETDEWEB)

    Joseph, Ilon [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-05-27

    Jacobian-free Newton-Krylov (JFNK) algorithms are a potentially powerful class of methods for solving the problem of coupling codes that address dfferent physics models. As communication capability between individual submodules varies, different choices of coupling algorithms are required. The more communication that is available, the more possible it becomes to exploit the simple sparsity pattern of the Jacobian, albeit of a large system. The less communication that is available, the more dense the Jacobian matrices become and new types of preconditioners must be sought to efficiently take large time steps. In general, methods that use constrained or reduced subsystems can offer a compromise in complexity. The specific problem of coupling a fluid plasma code to a kinetic neutrals code is discussed as an example.

  7. Air plasma coupled with antibody-conjugated nanoparticles: a new weapon against cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, G C; Park, S R [Department of Oral Anatomy and Cell Biology, School of Dentistry, Pusan National University, Busan 602-739 (Korea, Republic of); Kim, G J; Lee, J K [Department of Electronic and Electrical Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Jeon, S M; Seo, H J [Department of Chemical Engineering, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Iza, F, E-mail: jkl@postech.ac.k [Department of Electronic and Electrical Engineering, Loughborough University, Leicestershire LE11-3TU (United Kingdom)

    2009-02-07

    Ambient air plasmas have been known to kill cancer cells. To enhance selectivity we have used antibody-conjugated nanoparticles. We achieved five times enhancement of melanoma cell death over the case of the plasma alone by using an air plasma with gold nanoparticles bound to anti-FAK antibodies. Our results show that this new interdisciplinary technique has enormous potential for use as a complement to conventional therapies. (fast track communication)

  8. Degradation and modification of stainless-steel surface using Cl{sub 2}/Ar inductively coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hanbyeol [Dept. of Control and Instrumentation Engineering, Korea University, 2511 Sejong-Ro (Korea, Republic of); Efremov, Alexander [Dept. of Electronic Devices and Materials Technology, State University of Chemistry and Technology, 7 F. Engels st., 153000 Ivanovo (Russian Federation); Yun, Sun Jin [Electronic and Telecommunications Research Institute, Daejon 305-350 (Korea, Republic of); Yeom, Geun Young [Dept. of Advanced Materials Science and Engineering, Sungkyunkwan University, Suwon 440-746 (Korea, Republic of); Kim, Kyoung Bo [POSCO Global R and D Center, Open Innovation Lab., Incheon 406-840 (Korea, Republic of); Kwon, Kwang-Ho, E-mail: kwonkh@korea.ac.kr [Dept. of Control and Instrumentation Engineering, Korea University, 2511 Sejong-Ro (Korea, Republic of)

    2013-08-15

    The investigations of stainless steel (SS) etching behavior in the Cl{sub 2}/Ar inductively coupled plasma as well as the etched surface characteristics were carried out. It was found that an increase in Ar fraction in the Cl{sub 2}/Ar plasma from 0 to 100% at fixed gas pressure, input power and bias power results in decreasing both etching (degradation) rate of the SS surface (41.3–1.5 nm/min) and mean SS surface roughness (84–20 nm). Plasma diagnostics by Langmuir probes and 0-dimensional plasma modeling provided the data on plasma parameters, steady-state densities and fluxes of active species on the etched surface. It was shown that the maximum changes in mean roughness as well as in both polar and dispersive components of free surface energy correspond to a maximum value of Cl atom flux/ion flux ratio. Also, the linear correlation between free surface energy and mean roughness was obtained.

  9. Inductively and capacitively coupled plasmas at interface: A comparative study towards highly efficient amorphous-crystalline Si solar cells

    Science.gov (United States)

    Guo, Yingnan; Ong, Thiam Min Brian; Levchenko, I.; Xu, Shuyan

    2018-01-01

    A comparative study on the application of two quite different plasma-based techniques to the preparation of amorphous/crystalline silicon (a-Si:H/c-Si) interfaces for solar cells is presented. The interfaces were fabricated and processed by hydrogen plasma treatment using the conventional plasma-enhanced chemical vacuum deposition (PECVD) and inductively coupled plasma chemical vapour deposition (ICP-CVD) methods The influence of processing temperature, radio-frequency power, treatment duration and other parameters on interface properties and degree of surface passivation were studied. It was found that passivation could be improved by post-deposition treatment using both ICP-CVD and PECVD, but PECVD treatment is more efficient for the improvement on passivation quality, whereas the minority carrier lifetime increased from 1.65 × 10-4 to 2.25 × 10-4 and 3.35 × 10-4 s after the hydrogen plasma treatment by ICP-CVD and PECVD, respectively. In addition to the improvement of carrier lifetimes at low temperatures, low RF powers and short processing times, both techniques are efficient in band gap adjustment at sophisticated interfaces.

  10. A fully-implicit Particle-In-Cell Monte Carlo Collision code for the simulation of inductively coupled plasmas

    Science.gov (United States)

    Mattei, S.; Nishida, K.; Onai, M.; Lettry, J.; Tran, M. Q.; Hatayama, A.

    2017-12-01

    We present a fully-implicit electromagnetic Particle-In-Cell Monte Carlo collision code, called NINJA, written for the simulation of inductively coupled plasmas. NINJA employs a kinetic enslaved Jacobian-Free Newton Krylov method to solve self-consistently the interaction between the electromagnetic field generated by the radio-frequency coil and the plasma response. The simulated plasma includes a kinetic description of charged and neutral species as well as the collision processes between them. The algorithm allows simulations with cell sizes much larger than the Debye length and time steps in excess of the Courant-Friedrichs-Lewy condition whilst preserving the conservation of the total energy. The code is applied to the simulation of the plasma discharge of the Linac4 H- ion source at CERN. Simulation results of plasma density, temperature and EEDF are discussed and compared with optical emission spectroscopy measurements. A systematic study of the energy conservation as a function of the numerical parameters is presented.

  11. Plasma Membrane Na+-Coupled Citrate Transporter (SLC13A5 and Neonatal Epileptic Encephalopathy

    Directory of Open Access Journals (Sweden)

    Yangzom D. Bhutia

    2017-02-01

    Full Text Available SLC13A5 is a Na+-coupled transporter for citrate that is expressed in the plasma membrane of specific cell types in the liver, testis, and brain. It is an electrogenic transporter with a Na+:citrate3− stoichiometry of 4:1. In humans, the Michaelis constant for SLC13A5 to transport citrate is ~600 μM, which is physiologically relevant given that the normal concentration of citrate in plasma is in the range of 150–200 μM. Li+ stimulates the transport function of human SLC13A5 at concentrations that are in the therapeutic range in patients on lithium therapy. Human SLC13A5 differs from rodent Slc13a5 in two important aspects: the affinity of the human transporter for citrate is ~30-fold less than that of the rodent transporter, thus making human SLC13A5 a low-affinity/high-capacity transporter and the rodent Slc13a5 a high-affinity/low-capacity transporter. In the liver, SLC13A5 is expressed exclusively in the sinusoidal membrane of the hepatocytes, where it plays a role in the uptake of circulating citrate from the sinusoidal blood for metabolic use. In the testis, the transporter is expressed only in spermatozoa, which is also only in the mid piece where mitochondria are located; the likely function of the transporter in spermatozoa is to mediate the uptake of citrate present at high levels in the seminal fluid for subsequent metabolism in the sperm mitochondria to generate biological energy, thereby supporting sperm motility. In the brain, the transporter is expressed mostly in neurons. As astrocytes secrete citrate into extracellular medium, the potential function of SLC13A5 in neurons is to mediate the uptake of circulating citrate and astrocyte-released citrate for subsequent metabolism. Slc13a5-knockout mice have been generated; these mice do not have any overt phenotype but are resistant to experimentally induced metabolic syndrome. Recently however, loss-of-function mutations in human SLC13A5 have been found to cause severe epilepsy

  12. The effect of dielectric top lids on materials processing in a low frequency inductively coupled plasma (LF-ICP) reactor

    Science.gov (United States)

    Lim, J. W. M.; Chan, C. S.; Xu, L.; Xu, S.

    2014-08-01

    The advent of the plasma revolution began in the 1970's with the exploitation of plasma sources for anisotropic etching and processing of materials. In recent years, plasma processing has gained popularity, with research institutions adopting projects in the field and industries implementing dry processing in their production lines. The advantages of utilizing plasma sources would be uniform processing over a large exposed surface area, and the reduction of toxic emissions. This leads to reduced costs borne by manufacturers which could be passed down as consumer savings, and a reduction in negative environmental impacts. Yet, one constraint that plagues the industry would be the control of contaminants in a plasma reactor which becomes evident when reactions are conducted in a clean vacuum environment. In this work, amorphous silicon (a-Si) thin films were grown on glass substrates in a low frequency inductively coupled plasma (LF-ICP) reactor with a top lid made of quartz. Even though the chamber was kept at high vacuum ( 10-4 Pa), it was evident through secondary ion mass spectroscopy (SIMS) and Fourier-transform infra-red spectroscopy (FTIR) that oxygen contaminants were present. With the aid of optical emission spectroscopy (OES) the contaminant species were identified. The design of the LF-ICP reactor was then modified to incorporate an Alumina (Al2O3) lid. Results indicate that there were reduced amounts of contaminants present in the reactor, and that an added benefit of increased power transfer to the plasma, improving deposition rate of thin films was realized. The results of this study is conclusive in showing that Al2O3 is a good alternative as a top-lid of an LF-ICP reactor, and offers industries a solution in improving quality and rate of growth of thin films.

  13. Inductive couple plasma reactive ion etching characteristics of TiO{sub 2} thin films

    Energy Technology Data Exchange (ETDEWEB)

    Garay, Adrian Adalberto; Hwang, Su Min; Chung, Chee Won, E-mail: cwchung@inha.ac.kr

    2015-07-31

    Changes in the inductively coupled plasma reactive ion etching characteristics of TiO{sub 2} thin films in response to the addition of HBr, Cl{sub 2} and C{sub 2}F{sub 6} to Ar gas were investigated. As the HBr, Cl{sub 2} and C{sub 2}F{sub 6} concentration increased, the etch rate increased; however, the etch profile degree of anisotropy followed a different trend. As HBr concentration increased, the greatest anisotropic etch profile was obtained at 100% HBr, while the greatest anisotropic etch profile was obtained at concentrations of 25% when etching was conducted under C{sub 2}F{sub 6} and Cl{sub 2}. Field emission scanning electron microscopy revealed that 25% C{sub 2}F{sub 6} generated the greatest vertical etch profile; hence, etch parameters were varied at this concentration. The effects of rf power, dc-bias voltage and gas pressure on the etch rate and etch profile were also investigated. The etch rate and degree of anisotropy in the etch profile increased with increasing rf power and dc-bias voltage and decreasing gas pressure. X-ray photoelectron spectroscopy analysis of the films etched under a C{sub 2}F{sub 6}/Ar gas mixture revealed the existence of etch byproducts containing F (i.e. TiF{sub x}) over the film. C{sub x}F{sub y} compounds were not detected on the film surface, probably due to contamination with atmospheric carbon. - Highlights: • Reactive ion etching of TiO{sub 2} films under HBr, C{sub 2}F{sub 6}, and Cl{sub 2} gases was studied. • Etch rate and etch profile of TiO{sub 2} films were investigated under each gas chemistry. • The highest degree of anisotropy was achieved at 25% C{sub 2}F{sub 6}/Ar. • Strong etch conditions at 25% C{sub 2}F{sub 6}/Ar increased etch rate and degree of anisotropy. • X-ray photoelectron spectroscopy revealed the existence of F-containing etch residues.

  14. Laser ablation inductively coupled plasma optical emission spectrometry for analysis of pellets of plant materials

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Marcos S. [Departamento de Química, Universidade Federal de São Carlos, Rod. Washington Luís, km 235, 13565-905 São Carlos, SP (Brazil); Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Av. Centenário 303, 13416-000 Piracicaba, SP (Brazil); Schenk, Emily R. [Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States); International Forensic Research Institute, Florida International University, Miami, FL (United States); Santos, Dário [Departamento de Ciências Exatas e da Terra, Universidade Federal de São Paulo, Rua Professor Arthur Riedel 275, Diadema, SP (Brazil); Krug, Francisco José [Centro de Energia Nuclear na Agricultura, Universidade de São Paulo, Av. Centenário 303, 13416-000 Piracicaba, SP (Brazil); Almirall, José R., E-mail: almirall@fiu.edu [Department of Chemistry and Biochemistry, Florida International University, Miami, FL (United States); International Forensic Research Institute, Florida International University, Miami, FL (United States)

    2014-04-01

    An evaluation of laser ablation inductively coupled plasma optical emission spectroscopy (LAICP OES) for the direct analysis of pelleted plant material is reported. Ground leaves of orange citrus, soy and sugarcane were comminuted using a high-speed ball mill, pressed into pellets and sampled directly with laser ablation and analyzed by ICP OES. The limits of detection (LODs) for the method ranged from as low as 0.1 mg kg{sup −1} for Zn to as high as 94 mg kg{sup −1} for K but were generally below 6 mg kg{sup −1} for most of the elements of interest. A certified reference material consisting of a similar matrix (NIST SRM 1547 peach leaves) was used to check the accuracy of the calibration and the reported method resulted in an average bias of ∼ 5% for all the elements of interest. The precision for the reported method ranged from as low as 4% relative standard deviation (RSD) for Mn to as high as 17% RSD for Zn but averaged ∼ 6.5% RSD for all the elements (n = 10). The proposed method was tested for the determination of Ca, Mg, P, K, Fe, Mn, Zn and B, and the results were in good agreement with those obtained for the corresponding acid digests by ICP-OES, no differences being observed by applying a paired t-test at the 95% confidence level. The reported direct solid sampling method provides a fast alternative to acid digestion that results in similar and appropriate analytical figures of merit with regard to sensitivity, accuracy and precision for plant material analysis. - Highlights: • An evaluation of LA-ICP-OES for the direct analysis of pelleted plant material is reported. • Orange citrus, soy and sugarcane plants were pressed into pellets and sampled directly. • The element menu consisted of Ca, Mg, P, K, Fe, Mn, Zn and B. • LODs for the method ranged from 0.1 mg kg{sup −1} for Zn to 94 mg kg{sup −1} for K. • The precision ranged from 4% RSD for Mn to 17% RSD for Zn (∼ 6.5% RSD average)

  15. 99Tc bioassay by inductively coupled plasma mass spectrometry (ICP-MS)

    International Nuclear Information System (INIS)

    Lewis, L.A.

    1998-05-01

    A means of analyzing 99 Tc in urine by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. Historically, 99 Tc analysis was based on the radiometric detection of the 293 keV E Max beta decay product by liquid scintillation or gas flow proportional counting. In a urine matrix, the analysis of 99 Tc is plagued with many difficulties using conventional radiometric methods. Difficulties originate during chemical separation due to the volatile nature of Tc 2 O 7 or during radiation detection due to color or chemical quenching. A separation scheme for 99 Tc detection by ICP-MS is given and is proven to be a sensitive and robust analytical alternative. A comparison of methods using radiometric and mass quantitation of 99 Tc has been conducted in water, artificial urine, and real urine matrices at activity levels between 700 and 2,200 dpm/L. Liquid scintillation results based on an external standard quench correction and a quench curve correction method are compared to results obtained by ICP-MS. Each method produced accurate results, however the precision of the ICP-MS results is superior to that of liquid scintillation results. Limits of detection (LOD) for ICP-MS and liquid scintillation detection are 14.67 and 203.4 dpm/L, respectively, in a real urine matrix. In order to determine the basis for the increased precision of the ICP-MS results, the detection sensitivity for each method is derived and measured. The detection sensitivity for the 99 Tc isotope by ICP-MS is 2.175 x 10 -7 ± 8.990 x 10 -9 and by liquid scintillation is 7.434 x 10 -14 ± 7.461 x 10 -15 . A difference by seven orders of magnitude between the two detection systems allows ICP-MS samples to be analyzed for a period of 15 s compared to 3,600 s by liquid scintillation counting with a lower LOD

  16. Emission of strong Terahertz pulses from laser wakefields in weakly coupled plasma

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Divya, E-mail: dsingh@rajdhani.du.ac.in [PWAPA Laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi 110 016 (India); Department of Physics & Electronics, Rajdhani College, University of Delhi, Raja Garden, Ring Road, New Delhi 110015 (India); Malik, Hitendra K. [PWAPA Laboratory, Department of Physics, Indian Institute of Technology Delhi, New Delhi 110 016 (India)

    2016-09-01

    The present paper discusses the laser plasma interaction for the wakefield excitation and the role of external magnetic field for the emission of Terahertz radiation in a collisional plasma. Flat top lasers are shown to be more appropriate than the conventional Gaussian lasers for the effective excitation of wakefields and hence, the generation of strong Terahertz radiation through the transverse component of wakefield.

  17. Long distance coupling of lower hybrid waves in JET plasmas with edge and coretransport barriers

    Czech Academy of Sciences Publication Activity Database

    Ekedahl, A.; Granucci, G.; Mailloux, J.; Baranov, Y.; Erents, S. K.; Joffrin, E.; Litaudon, X.; Loarte, A.; Lomas, P. J.; McDonald, D.; Petržílka, Václav; Rantamäki, K.; Rimini, F.G.; Silva, C.; Stamp, M.; Tuccillo, A. A.

    2005-01-01

    Roč. 45, č. 5 (2005), s. 351-359 ISSN 0029-5515 Institutional research plan: CEZ:AV0Z20430508 Keywords : LH grill * plasma Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.418, year: 2005

  18. Assessment of high precision, high accuracy Inductively Coupled Plasma-Optical Emission Spectroscopy to obtain concentration uncertainties less than 0.2% with variable matrix concentrations

    International Nuclear Information System (INIS)

    Rabb, Savelas A.; Olesik, John W.

    2008-01-01

    The ability to obtain high precision, high accuracy measurements in samples with complex matrices using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy (HP-ICP-OES) was investigated. The Common Analyte Internal Standard (CAIS) procedure was incorporated into the High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method to correct for matrix-induced changes in emission intensity ratios. Matrix matching and standard addition approaches to minimize matrix-induced errors when using High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy were also assessed. The High Performance Inductively Coupled Plasma-Optical Emission Spectroscopy method was tested with synthetic solutions in a variety of matrices, alloy standard reference materials and geological reference materials

  19. Exploiting flow injection and sequential injection for trace metal determinations in conjunction with detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    Despite their excellent analytical chemical capacities, Electrothermal Atomic Absorption Spectrometry (ETAAS) and Inductively Coupled Plasma Mass Spectrometry (ICPMS), nevertheless, often require suitable pretreatment of the sample material in order to obtain the necessary sensitivity...

  20. Optical Studies of Strong Coupling and Recombination in Ultracold Neutral Plasmas

    International Nuclear Information System (INIS)

    Killian, Thomas C.

    2004-01-01

    The ultracold atoms and plasmas research group at Rice University uses a combination of atomic and plasma physics techniques to create neutral plasmas that are orders of magnitude colder than have ever been studied before. Through this work, we probe the basic plasma physics of this exotic regime. During the past year, the major components of a new experiment were completed. We demonstrated a powerful new diagnostic, optical imaging of the plasma, which led to a paper that was published in Physical Review Letters. (Figure A, Phys. Rev. Lett. 92, 143001 (2004)) This was the central feature of my DOE Junior Faculty Award proposal. DOE funding has been used to support one postdoctoral researcher, multiple graduate students, the principle investigator, apparatus construction, and normal laboratory expenses

  1. Optoelectronic properties of Black-Silicon generated through inductively coupled plasma (ICP) processing for crystalline silicon solar cells

    Science.gov (United States)

    Hirsch, Jens; Gaudig, Maria; Bernhard, Norbert; Lausch, Dominik

    2016-06-01

    The optoelectronic properties of maskless inductively coupled plasma (ICP) generated black silicon through SF6 and O2 are analyzed by using reflection measurements, scanning electron microscopy (SEM) and quasi steady state photoconductivity (QSSPC). The results are discussed and compared to capacitively coupled plasma (CCP) and industrial standard wet chemical textures. The ICP process forms parabolic like surface structures in a scale of 500 nm. This surface structure reduces the average hemispherical reflection between 300 and 1120 nm up to 8%. Additionally, the ICP texture shows a weak increase of the hemispherical reflection under tilted angles of incidence up to 60°. Furthermore, we report that the ICP process is independent of the crystal orientation and the surface roughness. This allows the texturing of monocrystalline, multicrystalline and kerf-less wafers using the same parameter set. The ICP generation of black silicon does not apply a self-bias on the silicon sample. Therefore, the silicon sample is exposed to a reduced ion bombardment, which reduces the plasma induced surface damage. This leads to an enhancement of the effective charge carrier lifetime up to 2.5 ms at 1015 cm-3 minority carrier density (MCD) after an atomic layer deposition (ALD) with Al2O3. Since excellent etch results were obtained already after 4 min process time, we conclude that the ICP generation of black silicon is a promising technique to substitute the industrial state of the art wet chemical textures in the solar cell mass production.

  2. In-situ determination of cross-over point for overcoming plasma-related matrix effects in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Chan, George C.-Y.; Hieftje, Gary M.

    2008-01-01

    A novel method is described for overcoming plasma-related matrix effects in inductively coupled plasma-atomic emission spectrometry (ICP-AES). The method is based on measurement of the vertically resolved atomic emission of analyte within the plasma and therefore requires the addition of no reagents to the sample solution or to the plasma. Plasma-related matrix effects enhance analyte emission intensity low in the plasma but depress the same emission signal at higher positions. Such bipolar behavior is true for all emission lines and matrices that induce plasma-related interferences. The transition where the enhancement is balanced by the depression (the so-called cross-over point) results in a spatial region with no apparent matrix effects. Although it would be desirable always to perform determinations at this cross-over point, its location varies between analytes and from matrix to matrix, so it would have to be found separately for every analyte and for every sample. Here, a novel approach is developed for the in-situ determination of the location of this cross-over point. It was found that the location of the cross-over point is practically invariant for a particular analyte emission line when the concentration of the matrix was varied. As a result, it is possible to determine in-situ the location of the cross-over point for all analyte emission lines in a sample by means of a simple one-step sample dilution. When the original sample is diluted by a factor of 2 and the diluted sample is analyzed again, the extent of the matrix effect is identical (zero) between the original sample and the diluted sample at one and only one location - the cross-over point. This novel method was verified with several single-element matrices (0.05 M Na, Ca, Ba and La) and some mixed-element matrices (mixtures of Na-Ca, Ca-Ba, and a plant-sample digest). The inaccuracy in emission intensity due to the matrix effect could be as large as - 30% for conventional measurements in the

  3. Electromagnetic dynamic response of HL-2M vacuum vessel under plasma disruption considering the electromagneto-mechanical coupling effect

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Hongwei; Yuan, Zhensheng; Li, Weixin; Pei, Cuixiang; Xie, Shejuan [State Key Laboratory for Strength and Vibration of Mechanical Structures, Shaanxi Engineering Research Center for NDT and Structural Integrity Evaluation, Xi’an Jiaotong University, Xi’an 710049 (China); Chen, Zhenmao, E-mail: chenzm@mail.xjtu.edu.cn [State Key Laboratory for Strength and Vibration of Mechanical Structures, Shaanxi Engineering Research Center for NDT and Structural Integrity Evaluation, Xi’an Jiaotong University, Xi’an 710049 (China); Pan, Yudong; Cai, Lijun; Li, Jiaxian [Southwestern Institute of Physics, Chengdu 610041 (China)

    2016-11-01

    Highlights: • A 1/5 numerical model is established and validated for HL-2M vacuum vessel. • The Lagrangian approach used for treating the EM-mechanical coupling problem is introduced. • The EM field and structural dynamic response of HL-2M VV during plasma disruptions are simulated by using the Lagrangian strategy. • The dynamic responses of the VV of HL-2M are compared to clarify the effect of the EM-mechanical coupling under the MD and VED conditions. • The results present a basis for the safe operation of the HL-2M VV device. - Abstract: During plasma disruptions (PDs), transient eddy currents are induced in the HL-2M vacuum vessel (VV) which is a D-shaped, double thin-wall structure. Under the circumstance of high magnetic field, the resulting electromagnetic (EM) forces during PDs are large and the dynamic response of related structures may be violent. In this complicated EM circumstance, the EM-mechanical coupling effect may also have a great influence on the dynamic response of VV structure. In this paper, the EM field and structural dynamic response of HL-2M VV during PDs are simulated by adopting a numerical code of the Lagrangian approach. The Lagrangian approach is on the basis of the Maxwell equations in the Lagrangian description, which treats the coupling behavior of magnetic damping effect without explicitly using the velocity term. This approach can be easily applied to actual structures by updating FEM meshes and reforming coefficient matrices before calculating EM field at each time step. In this work, the disruption plasma currents of operating conditions are simulated by using the DINA code and then the dynamic responses of displacements and stresses of the VV of HL-2M are obtained for both cases with and without considering the coupling effect. The numerical results show that stresses under the disruptions (MD and VDE) are not significant and the coupling effect does not significantly affect the peak dynamic response for the HL-2M

  4. Coupling and absorption of lower-hybrid waves in a thermonuclear plasma

    International Nuclear Information System (INIS)

    Puri, S.; Tutter, M.

    1975-01-01

    The three important aspects, namely 1) accessibility, 2) matching and 3) absorption of the lower-hybrid waves in a thermonuclear plasma are studied under idealized but physically pertinent conditions within the framework of linearized theory. (orig.) [de

  5. Strongly-coupled nature of the primordial SUSY SU(5) plasma

    International Nuclear Information System (INIS)

    Goldberg, H.

    1984-01-01

    It is shown that for a large class of SU(5) SUSY GUTs, (i) the Debye free energy of the plasma is 2-3 times larger than the free energy of the SUSY SU(5) ideal gas; (ii) the mean free path of an SU(5) gluon in the plasma is about 1/3 of the average interquantum spacing of the ideal gas. Possible implications for inflationary scenarios are discussed. (orig.)

  6. Characterization of a 50kW Inductively Coupled Plasma Torch for Testing of Ablative Thermal Protection Materials

    Science.gov (United States)

    Greene, Benton R.; Clemens, Noel T.; Varghese, Philip L.; Bouslog, Stanley A.; Del Papa, Steven V.

    2017-01-01

    With the development of new manned spaceflight capabilities including NASA's Orion capsule and the Space-X Dragon capsule, there is a renewed importance of understanding the dynamics of ablative thermal protection systems. To this end, a new inductively coupled plasma torch facility is being developed at UT-Austin. The torch operates on argon and/or air at plasma powers up to 50 kW. In the present configuration the flow issues from a low-speed subsonic nozzle and the hot plume is characterized using slug calorimetry and emission spectroscopy. Preliminary measurements using emission spectroscopy have indicated that the torch is capable of producing an air plasma with a temperature between 6,000 K and 8,000 K depending on the power and flow settings and an argon plasma with a temperature of approximately 12,000 K. The operation envelope was measured, and heat flux measured for every point within the envelope using both a slug calorimeter and a Gardon gauge heat flux sensor. The torch was found to induce a stagnation point heat flux of between 90 and 225 W/sq cm.

  7. Quasilongitudinal soliton in a two-dimensional strongly coupled complex dusty plasma in the presence of an external magnetic field.

    Science.gov (United States)

    Ghosh, Samiran

    2014-09-01

    The propagation of a nonlinear low-frequency mode in two-dimensional (2D) monolayer hexagonal dusty plasma crystal in presence of external magnetic field and dust-neutral collision is investigated. The standard perturbative approach leads to a 2D Korteweg-de Vries (KdV) soliton for the well-known dust-lattice mode. However, the Coriolis force due to crystal rotation and Lorentz force due to magnetic field on dust particles introduce a linear forcing term, whereas dust-neutral drag introduce the usual damping term in the 2D KdV equation. This new nonlinear equation is solved both analytically and numerically to show the competition between the linear forcing and damping in the formation of quasilongitudinal soliton in a 2D strongly coupled complex (dusty) plasma. Numerical simulation on the basis of the typical experimental plasma parameters and the analytical solution reveal that the neutral drag force is responsible for the usual exponential decay of the soliton, whereas Coriolis and/or Lorentz force is responsible for the algebraic decay as well as the oscillating tail formation of the soliton. The results are discussed in the context of the plasma crystal experiment.

  8. Application of relativistic coupled cluster linear response theory to helium-like ions embedded in plasma environment

    Science.gov (United States)

    Das, Madhulita; Chaudhuri, Rajat K.; Chattopadhyay, Sudip; Sinha Mahapatra, Uttam; Mukherjee, P. K.

    2011-08-01

    Ionization potential and low lying 1S0\\longrightarrow1P1 excitation energies (EE) of highly stripped He-like ions C4 +, Al11 +, and Ar16 + embedded in plasma environment are calculated for the first time using the state-of-the-art coupled cluster (CC)-based linear response theory (LRT) with the four-component relativistic spinors and compared with available experimental data from laser plasma experiments. Debye's screening model is used to estimate the effect of plasma on the ions within the relativistic and non-relativistic framework. The transition energies computed at the CCLRT level using the Debye model agree well with experiment and with other available theoretical data. To our knowledge, no prior CCLRT calculations within the Dirac-Fock framework are available for these systems. Our calculated transition energies for helium-like ions are in accord with experiment; we trust that our predicted EE might be acceptably good for the systems considered. Our preliminary result indicates that CCLRT with the four-component relativistic spinors appears to be a valuable tool for studying the atomic systems where accurate treatments of correlation effects play a crucial role in shaping the spectral lines of ions subjected to plasma environment.

  9. Ionization of elements in medium power capacitively coupled argon plasma torch with single and double ring electrodes.

    Science.gov (United States)

    Ponta, Michaela; Frentiu, Maria; Frentiu, Tiberiu

    2012-06-01

    A medium power, low Ar consumption capacitively coupled plasma torch (275 W, 0.4 L min-1) with molybdenum tubular electrode and single or two ring electrodes in non-local thermodynamic equilibrium (LTE) was characterized with respect to its ability to achieve element ionization. Ionization degrees of Ca, Mg, Mn and Cd were determined from ionic-to-atomic emission ratio and ionization equilibrium according to Saha's equation. The ionization degrees resulted from the Saha equation were higher by 9-32% than those obtained from spectral lines intensity in LTE regime and closer to reality. A linear decrease of ionization with increase of ionization energy of elements was observed. Plasma torch with two ring electrodes provided higher ionization degrees (85 ± 7% Ca, 79 ± 7% Mn, 80 ± 7% Mg and 73 ± 8% Cd) than those in single ring arrangement (70 ± 6% Ca, 57 ± 7% Mn, 57 ± 8% Mg and 42 ± 9% Cd). The Ca ionization decreased linearly by up to 79 ± 4% and 53 ± 6% in plasma with two ring electrodes and single ring respectively in the presence of up to 400 µg mL-1 Na as interferent. The studied plasma was effective in element ionization and could be a potential ion source in mass spectrometry.

  10. Validation of determination of plasma metabolites derived from thyme bioactive compounds by improved liquid chromatography coupled to tandem mass spectrometry.

    Science.gov (United States)

    Rubió, Laura; Serra, Aida; Macià, Alba; Borràs, Xenia; Romero, Maria-Paz; Motilva, Maria-José

    2012-09-15

    In the present study, a selective and sensitive method, based on microelution solid-phase extraction (μSPE) plate and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) was validated and applied to determine the plasma metabolites of the bioactive compounds of thyme. For validation process, standards of the more representative components of the phenolic and monoterpene fractions of thyme were spiked in plasma samples and then the quality parameters of the method were studied. Extraction recoveries (%R) of the studied compounds were higher than 75%, and the matrix effect (%ME) was lower than 18%. The LODs ranged from 1 to 65 μg/L, except for the thymol sulfate metabolite, which was 240 μg/L. This method was then applied for the analysis of rat plasma obtained at different times, from 0 to 6h, after an acute intake of thyme extract (5 g/kg body weight). Different thyme metabolites were identified and were mainly derived from rosmarinic acid (coumaric acid sulfate, caffeic acid sulfate, ferulic acid sulfate, hydroxyphenylpropionic acid sulfate, dihydroxyphenylpropionic acid sulfate and hydroxybenzoic acid) and thymol (thymol sulfate and thymol glucuronide). The most abundant thyme metabolites generated were hydroxyphenylpropionic acid sulfate and thymol sulfate, their respective concentrations in plasma being 446 and 8464 μM 1h after the intake of the thyme extract. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Development and evaluation of high resolution quadrupole mass analyzer and an inductively coupled plasma-Mach disk

    Energy Technology Data Exchange (ETDEWEB)

    Amad, Ma' an Hazem [Iowa State Univ., Ames, IA (United States)

    1999-12-10

    By definition a plasma is an electrically conducting gaseous mixture containing a significant concentration of cations and electrons. The Inductively Coupled Plasma (ICP) is an electrodeless discharge in a gas at atmospheric pressure. This discharge is an excellent one for vaporizing, atomizing, and ionizing elements. The early development of the ICP began in 1942 by Babat and then by Reed in the early 1960s. This was then followed by the pioneering work of Fassel and coworkers in the late 1960s. Commercial ICP spectrometers were introduced in the mid 1970s. A major breakthrough in the area of ICP took place in the early 1980s when the ICP was shown to be an excellent ion source for mass spectrometry.

  12. Investigation of InP etching mechanisms in a Cl2/H2 inductively coupled plasma by optical emission spectroscopy

    International Nuclear Information System (INIS)

    Gatilova, L.; Bouchoule, S.; Guilet, S.; Chabert, P.

    2009-01-01

    Optical emission spectroscopy (OES) has been used in order to investigate the InP etching mechanisms in a Cl 2 -H 2 inductively coupled plasma. The authors have previously shown that anisotropic etching of InP could be achieved for a H 2 percentage in the 35%-45% range where the InP etch rate also presents a local maximum [J. Vac. Sci. Technol. B 24, 2381 (2006)], and that anisotropic etching was due to an enhanced passivation of the etched sidewalls by a silicon oxide layer [J. Vac. Sci. Technol. B 26, 666 (2008)]. In this work, it is shown that this etching behavior is related to a maximum in the H atom concentration in the plasma. The possible enhancement of the sidewall passivation process in the presence of H is investigated by comparing OES measurements and etching results obtained for Cl 2 -H 2 and Cl 2 -Ar gas mixtures

  13. Sample treatment procedures for the determination of mineral constituents in honey by Inductively Coupled Plasma Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    Mendes Teresa M. F. F.

    2006-01-01

    Full Text Available Preparative methods for quantification of inorganic constituents in honey by Inductively Coupled Plasma Optical Emission Spectrometry (ICP OES using microwave assisted digestion and ultrasonication procedures were developed. Analytical aspects such as matrix complexity, instrumental optimization and the essentiality/toxicity of the species K, Ca, Mg, Na, Fe, Mn, Zn, Cu, Co, Ni, Pb, Cd were considered. Parameters such as plasma power, nebulizer flow rate, torch configuration and the convenience of the use of yttrium as internal standard were evaluated. Recoveries between 93 and 107% (microwave digestion and between 90 to 110% (ultrasonication procedure and relative standard deviations lower than 10% were obtained. Samples of Brazilian honeys, from different parts of the country, were analysed and the results obtained provide relevant information about their mineral content.

  14. Room temperature inductively coupled plasma etching of InAs/InSb in BCl 3/Cl 2/Ar

    KAUST Repository

    Sun, Jian

    2012-10-01

    Inductively coupled plasma (ICP) etching of InAs and InSb at room temperature has been investigated using BCl 3/Cl 2/Ar plasma. Specifically, the etch rate and post-etching surface morphology were investigated as functions of the gas composition, ICP power, process pressure, and RF chuck power. An optimized process has been developed, yielding anisotropic etching and very smooth surfaces with roughnesses of 0.25 nm for InAs, and 0.57 nm for InSb, which is comparable with the surface of epi-ready polished wafers. The process provides moderate etching rates of 820 /min for InAs and 2800 /min for InSb, and the micro-masking effect is largely avoided. © 2012 Elsevier B.V. All rights reserved.

  15. Hyphenation of ultra performance liquid chromatography (UPLC) with inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of bromine containing preservatives

    DEFF Research Database (Denmark)

    Bendahl, Lars; Hansen, Steen Honoré; Gammelgaard, Bente

    2006-01-01

    Ultra performance liquid chromatography (UPLC) was coupled to inductively coupled plasma mass spectrometry (ICP-MS) for fast analysis of three bromine-containing preservatives, monitoring the 79Br and 81Br isotopes simultaneously. Due to the efficiency of the 1.7 microm column packing material, t...

  16. The response of the inductively coupled argon plasma to solvent plasma load: spatially resolved maps of electron density obtained from the intensity of one argon line

    Science.gov (United States)

    Weir, D. G. J.; Blades, M. W.

    1994-12-01

    A survey of spatially resolved electron number density ( ne) in the tail cone of the inductively coupled argon plasma (ICAP) is presented: all of the results of the survey have been radially inverted by numerical, asymmetric Abel inversion. The survey extends over the entire volume of the plasma beyond the exit of the ICAP torch; It extends over distances of z = 5-25 mm downstream from the induction coil, and over radial distances of ± 8 mm from the discharge axis. The survey also explores a range of inner argon flow rates ( QIN), solvent plasma load ( Qspl) and r.f. power: moreover, it explores loading by water, methanol and chloroform. Throughout the survey, ne was determined from the intensity of one, optically thin argon line, by a method which assumes that the atomic state distribution function (ASDF) for argon lies close to local thermal equilibrium (LTE). The validity of this assumption is reviewed. Also examined are the discrepancies between ne from this method and ne from Stark broadening measurements. With the error taken into account, the results of the survey reveal how time averaged values of ne in the ICAP respond over an extensive, previously unexplored range of experimental parameters. Moreover, the spatial information lends insight into how the thermal conditions and the transport of energy respond. Overall, the response may be described in terms of energy consumption along the axial channel and thermal pinch within the induction region. The predominating effect depends on the solvent plasma load, the solvent composition, the robustness of the discharge, and the distribution of solvent material over the argon stream.

  17. Inductively coupled plasma-atomic emission spectroscopy: a computer controlled, scanning monochromator system for the rapid determination of the elements

    Energy Technology Data Exchange (ETDEWEB)

    Floyd, M.A.

    1980-03-01

    A computer controlled, scanning monochromator system specifically designed for the rapid, sequential determination of the elements is described. The monochromator is combined with an inductively coupled plasma excitation source so that elements at major, minor, trace, and ultratrace levels may be determined, in sequence, without changing experimental parameters other than the spectral line observed. A number of distinctive features not found in previously described versions are incorporated into the system here described. Performance characteristics of the entire system and several analytical applications are discussed.

  18. Use of a parallel path nebulizer for capillary-based microseparation techniques coupled with an inductively coupled plasma mass spectrometer for speciation measurements

    International Nuclear Information System (INIS)

    Yanes, Enrique G.; Miller-Ihli, Nancy J.

    2004-01-01

    A low flow, parallel path Mira Mist CE nebulizer designed for capillary electrophoresis (CE) was evaluated as a function of make-up solution flow rate, composition, and concentration, as well as the nebulizer gas flow rate. This research was conducted in support of a project related to the separation and quantification of cobalamin (vitamin B-12) species using microseparation techniques combined with inductively coupled plasma mass spectrometry (ICP-MS) detection. As such, Co signals were monitored during the nebulizer characterization process. Transient effects in the ICP were studied to evaluate the suitability of using gradients for microseparations and the benefit of using methanol for the make-up solution was demonstrated. Co signal response changed significantly as a function of changing methanol concentrations of the make-up solution and maximum signal enhancement was seen at 20% methanol with a 15 μl/min flow rate. Evaluation of the effect of changing the nebulizer gas flow rates showed that argon flows from 0.8 to 1.2 l/min were equally effective. The Mira Mist CE parallel path nebulizer was then evaluated for interfacing capillary microseparation techniques including capillary electrophoresis (CE) and micro high performance liquid chromatography (μHPLC) to inductively coupled plasma mass spectrometry (ICP-MS). A mixture of four cobalamin species standards (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5' deoxyadenosylcobalamin) and the corrinoid analogue cobinamide dicyanide were successfully separated using both CE-ICP-MS and μHPLC-ICP-MS using the parallel path nebulizer with a make-up solution containing 20% methanol with a flow rate of 15 μl/min

  19. Simultaneous measurement of sulfur and lead isotopes in sulfides using nanosecond laser ablation coupled with two multi-collector inductively coupled plasma mass spectrometers

    Science.gov (United States)

    Yuan, Honglin; Liu, Xu; Chen, Lu; Bao, Zhian; Chen, Kaiyun; Zong, Chunlei; Li, Xiao-Chun; Qiu, Johnson Wenhong

    2018-04-01

    We herein report the coupling of a nanosecond laser ablation system with a large-scale multi-collector inductively coupled plasma mass spectrometer (Nu1700 MC-ICPMS, NP-1700) and a conventional Nu Plasma II MC-ICPMS (NP-II) for the simultaneous laser ablation and determination of in situ S and Pb isotopic compositions of sulfide minerals. We found that the required aerosol distribution between the two spectrometers depended on the Pb content of the sample. For example, for a sulfide containing 100-3000 ppm Pb, the aerosol was distributed between the NP-1700 and the NP-II spectrometers in a 1:1 ratio, while for lead contents >3000 and effect, so a matrix-matched external standard was used for standard-sample bracketing correction. The NIST NBS 977 (NBS, National Bureau of Standards; NIST, National Institute of Standards & Technology) Tl (thallium) dry aerosol internal standard and the NIST SRM 610 (SRM, standard reference material) external standard were employed to obtain accurate results for the analysis of Pb isotopes. In tandem experiments where airflow conditions were similar to those employed during stand-alone analyses, small changes in the aerosol carrier gas flow did not significantly influence the accurate determination of S and Pb isotope ratios. In addition, careful optimization of the flow ratio of the aerosol carrier (He) and makeup (Ar) gases to match stand-alone analytical conditions allowed comparable S and Pb isotope ratios to be obtained within an error of 2 s analytical uncertainties. Furthermore, the results of tandem analyses obtained using our method were consistent with those of previously reported stand-alone techniques for the S and Pb isotopes of chalcopyrite, pyrite, galena, and sphalerite, thus indicating that this method is suitable for the simultaneous analysis of S and Pb isotopes of natural sulfide minerals, and provides an effective tool to determine S and Pb isotope compositions of sulfides formed through multi-stage deposition

  20. Use of a parallel path nebulizer for capillary-based microseparation techniques coupled with an inductively coupled plasma mass spectrometer for speciation measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yanes, Enrique G. E-mail: yanes@bhnrc.usda.gov; Miller-Ihli, Nancy J. E-mail: miller-ihli@bhnrc.usda.gov

    2004-06-18

    A low flow, parallel path Mira Mist CE nebulizer designed for capillary electrophoresis (CE) was evaluated as a function of make-up solution flow rate, composition, and concentration, as well as the nebulizer gas flow rate. This research was conducted in support of a project related to the separation and quantification of cobalamin (vitamin B-12) species using microseparation techniques combined with inductively coupled plasma mass spectrometry (ICP-MS) detection. As such, Co signals were monitored during the nebulizer characterization process. Transient effects in the ICP were studied to evaluate the suitability of using gradients for microseparations and the benefit of using methanol for the make-up solution was demonstrated. Co signal response changed significantly as a function of changing methanol concentrations of the make-up solution and maximum signal enhancement was seen at 20% methanol with a 15 {mu}l/min flow rate. Evaluation of the effect of changing the nebulizer gas flow rates showed that argon flows from 0.8 to 1.2 l/min were equally effective. The Mira Mist CE parallel path nebulizer was then evaluated for interfacing capillary microseparation techniques including capillary electrophoresis (CE) and micro high performance liquid chromatography ({mu}HPLC) to inductively coupled plasma mass spectrometry (ICP-MS). A mixture of four cobalamin species standards (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5' deoxyadenosylcobalamin) and the corrinoid analogue cobinamide dicyanide were successfully separated using both CE-ICP-MS and {mu}HPLC-ICP-MS using the parallel path nebulizer with a make-up solution containing 20% methanol with a flow rate of 15 {mu}l/min.

  1. Extraction inductively coupled plasma-optical emission spectrometry (ICP-OES). Determination of traces of phosphorus in tungsten

    International Nuclear Information System (INIS)

    Bauer, G.; Wegscheider, W.; Mueller, K.

    1989-01-01

    A method for the separation and preconcentration of traces of phosphorus from tungsten was developed. Solid phase extraction of the phosphovanadomolybdate complex performed on a micro-column was applied. Phosphorus was determined by optical emission spectroscopy (OES) with inductively coupled plasma (ICP) excitation. A limit of detection of 0,4 μg/g P with respect to the solid phase is obtained. By directly coupling the extraction/elution step to the ICP instrument a detection limit of 0,06 μg/g P in W was achieved. Besides, the complexity of spectral evaluation in ICP-OES determinations of traces in spectralline-rich matrices is discussed. (Authors)

  2. Zonal drifts of plasma bubbles in South American sector during the extreme low solar activity 2008 - 2010.

    Science.gov (United States)

    Abalde, J. R.; Coelho, F. E.; Fagundes, P. R.; de Jesus, R.; Pillat, V. G.; de Abreu, A. J.

    2014-12-01

    Transequatorial F region plasma bubbles are large-scale ionospheric depleted regions that develop in the bottomside of equatorial F region due to plasma instability processes. All-sky imaging observations of the OI 630.0 nm nightglow emissions were carried out at Sao Jose dos Campos - SJC (23.21°S, 45.86°W; dip latitude 17.6°S) and Palmas - PAL (10.28°S, 48.33°W; dip latitude 6.7°S), Brazil, during the years 2008 and 2010, a period of minimum extreme solar activity. In this work we present and discuss the height-resolved nocturnal F region zonal drift velocities obtained from plasma bubbles observed in imaging observations of OI 630.0 nm emissions result from excitation mechanisms by dissociative recombination of O2. We have investigated the nighttime zonal plasma drift variations using fixed emission peak altitudes, used by earlier investigators, as well as emission peak altitudes based on simultaneous ionospheric sounding observations for both observatories. The average maximum and minimum zonal plasma drift velocities inferred for OI 630.0 nm emission, using emission peak altitudes based on simultaneous ionospheric observations, (SJC: 116 ± 7 and 57 ± 15 m/s; PAL: 119 ± 6 and 58 ± 10 m/s) are lower and with less scatter than that using fixed emission peak altitudes (SJC: 119 ± 6 and 58 ± 10 m/s; PAL: 111 ± 5 and 85 ± 10 m/s). Also, the nocturnal variations of the zonal plasma drift velocities obtained with peak altitudes based on simultaneous ionospheric observations show better agreement than for the case with fixed emission peak altitudes (h = 280 km).

  3. Comparison of inductively coupled plasma mass spectrometry with inductively coupled plasma atomic emission spectrometry and instrumental neutron activation analysis for the determination of rare earth elements in Greek bauxites

    International Nuclear Information System (INIS)

    Fore the determination of rare earth elements (REE) in bauxitic materials the techniques of inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES) and instrumental neutron activation analysis (INAA) were compared. In the NIST (National Institute of Standards and Technology) bauxites SRM 697 Dominican, and SRM 69 b Arkansas, the concentration of some REEs were determined. With the reference bauxite BX-N of the ARNT (Association Nationale de la Recherche Technique) the precision and accuracy of ICP-AES for the determination of REEs in bauxites was tested. Furthermore, Greek bauxites of the Parnassos-Giona area were investigated. In a comparison of the three methods it was possible to calculate from the data series the precision of each method, which showed that the tendency found in the deviations for the different REEs is in accordance with published values. Also the limits of detection for REEs in bauxites were calculated and found to be in the same range as those in the literature. (author)

  4. Determination of hafnium at the 10(-4)% level (relative to zirconium content) using neutron activation analysis, inductively coupled plasma mass spectrometry and inductively coupled plasma atomic emission spectrometry.

    Science.gov (United States)

    Smolik, Marek; Polkowska-Motrenko, Halina; Hubicki, Zbigniew; Jakóbik-Kolon, Agata; Danko, Bożena

    2014-01-02

    Hafnium at the very low level of 1-8 ppm (in relation to zirconium) was determined in zirconium sulfate solutions (originating from investigations of the separation of ca. 44 ppm Hf from zirconium by means of the ion exchange method) by using three independent methods: inductively coupled plasma mass spectrometry (ICP MS), neutron activation analysis (NAA) and inductively coupled plasma atomic emission spectrometry (ICP-AES). The results of NAA and ICP MS determinations were consistent with each other across the entire investigated range (the RSD of both methods did not exceed 38%). The results of ICP-AES determination were more diverse, particularly at less than 5 ppm Hf (RSD was significantly higher: 29-253%). The ion exchange method exploiting Diphonix(®) resin proved sufficient efficiency in Zr-Hf separation when the initial concentration ratio of the elements ([Zr]0/[Hf]0) ranged from 1200 to ca. 143,000. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Coupling of electromagnetics and structural/fluid dynamics - application to the dual coolant blanket subjected to plasma disruptions

    International Nuclear Information System (INIS)

    Jordan, T.

    1996-01-01

    Some aspects concerning the coupling of quasi-stationary electromagnetics and the dynamics of structure and fluid are investigated. The necessary equations are given in a dimensionless form. The dimensionless parameters in these equations are used to evaluate the importance of the different coupling effects. A finite element formulation of the eddy-current damping in solid structures is developed. With this formulation, an existing finite element method (FEM) structural dynamics code is extended and coupled to an FEM eddy-current code. With this program system, the influence of the eddy-current damping on the dynamic loading of the dual coolant blanket during a centered plasma disruption is determined. The analysis proves that only in loosely fixed or soft structures will eddy-current damping considerably reduce the resulting stresses. Additionally, the dynamic behavior of the liquid metal in the blankets' poloidal channels is described with a simple two-dimensional magnetohydrodynamic approach. The analysis of the dimensionless parameters shows that for small-scale experiments, which are designed to model the coupled electromagnetic and structural/fluid dynamic effects in such a blanket, the same magnetic fields must be applied as in the real fusion device. This will be the easiest way to design experiments that produce transferable results. 10 refs., 7 figs

  6. Recent results from experimental studies on laser-plasma coupling in a shock ignition relevant regime

    Czech Academy of Sciences Publication Activity Database

    Koester, P.; Antonelli, L.; Atzeni, S.; Badziak, J.; Baffigi, F.; Batani, D.; Cecchetti, C.A.; Chodukowski, T.; Consoli, F.; Cristoforetti, G.; De Angelis, R.; Folpini, G.; Gizzi, L.A.; Kalinowska, Z.; Krouský, Eduard; Kuchařík, M.; Labate, L.; Levato, T.; Liška, R.; Malka, G.; Maheut, Y.; Marocchino, A.; Nicolai, P.; O´Dell, T.; Parys, P.; Pisarczyk, T.; Rączka, P.; Renner, Oldřich; Rhee, Y.-J.; Ribeyre, X.; Richetta, M.; Rosinski, M.; Ryc, L.; Skála, Jiří; Schiavi, A.; Schurtz, G.; Šmíd, Michal; Spindloe, C.; Ullschmied, Jiří; Wolowski, J.; Zaras, A.

    2013-01-01

    Roč. 55, č. 12 (2013), , "124045-1"-"124045-8" ISSN 0741-3335 R&D Projects: GA MŠk(CZ) LC528; GA MŠk LM2010014 EU Projects: European Commission(XE) 284464 - LASERLAB-EUROPE Institutional support: RVO:68378271 ; RVO:61389021 Keywords : laser-produced plasmas * inertial confinement fusion * shock ignition * X-ray imaging spectroscopy * ion diagnostics * interferometry * shock breakout chron Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.386, year: 2013

  7. Molecular dynamics studies of electron-ion temperature equilibration in hydrogen plasmas within the coupled-mode regime.

    Science.gov (United States)

    Benedict, Lorin X; Surh, Michael P; Stanton, Liam G; Scullard, Christian R; Correa, Alfredo A; Castor, John I; Graziani, Frank R; Collins, Lee A; Čertík, Ondřej; Kress, Joel D; Murillo, Michael S

    2017-04-01

    We use classical molecular dynamics (MD) to study electron-ion temperature equilibration in two-component plasmas in regimes for which the presence of coupled collective modes has been predicted to substantively reduce the equilibration rate. Guided by previous kinetic theory work, we examine hydrogen plasmas at a density of n=10^{26}cm^{-3}, T_{i}=10^{5}K, and 10^{7}Kcoupled modes are neglected. We suggest possible reasons for this surprising result and propose directions of further research along these lines.

  8. Estimation of the quantification uncertainty from flow injection and liquid chromatography transient signals in inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Laborda, Francisco; Medrano, Jesus; Castillo, Juan R.

    2004-01-01

    The quality of the quantitative results obtained from transient signals in high-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICPMS) and flow injection-inductively coupled plasma mass spectrometry (FI-ICPMS) was investigated under multielement conditions. Quantification methods were based on multiple-point calibration by simple and weighted linear regression, and double-point calibration (measurement of the baseline and one standard). An uncertainty model, which includes the main sources of uncertainty from FI-ICPMS and HPLC-ICPMS (signal measurement, sample flow rate and injection volume), was developed to estimate peak area uncertainties and statistical weights used in weighted linear regression. The behaviour of the ICPMS instrument was characterized in order to be considered in the model, concluding that the instrument works as a concentration detector when it is used to monitorize transient signals from flow injection or chromatographic separations. Proper quantification by the three calibration methods was achieved when compared to reference materials, although the double-point calibration allowed to obtain results of the same quality as the multiple-point calibration, shortening the calibration time. Relative expanded uncertainties ranged from 10-20% for concentrations around the LOQ to 5% for concentrations higher than 100 times the LOQ

  9. Behavior of microorganisms in drinking water treatment by inductively coupled plasma system: Case study in ground water

    Science.gov (United States)

    Desmiarti, Reni; Hazmi, Ariadi; Martynis, Munas; Sutopo, Ulung Muhammad; Li, Fusheng

    2018-02-01

    Pathogenic bacteria, such as total coliforms (TC), fecal coliforms (FC) and other coliforms (OC), were removed from groundwater by inductively coupled plasma system treatment in continuous flow experiments. The objective of this study is to investigate the effect of flowrate and frequency on the behavior of microorganisms in drinking water treatment using inductively coupled plasma system (ICPS). The results showed that after 120 minutes of ICPS treatment, the removal efficiency with respect to TC, FC and OC decreased with increasing flowrate. The removal efficiency of FC was achieved at 100% in all runs. Compared to FC, the removal efficiencies with respect to TC and FC were lower than those with respect to TC and OC in the following order: FC >OC> TC. The disinfection yield of TC and OC significantly increased when the removal efficiency increased. The electromagnetic flux varied from 8.08±0.46 to 10.54±0.19 W/cm2. The results in the present work can be used to design a new technology for drinking water treatment to remove all pathogenic bacteria without using hazardous chemicals.

  10. Calibration of laser ablation inductively coupled plasma mass spectrometry using dried solution aerosols for the quantitative analysis of solid samples

    Energy Technology Data Exchange (ETDEWEB)

    Leach, James [Iowa State Univ., Ames, IA (United States)

    1999-02-12

    Inductively coupled plasma mass spectrometry (ICP-MS) has become the method of choice for elemental and isotopic analysis. Several factors contribute to its success. Modern instruments are capable of routine analysis at part per trillion levels with relative detection limits in part per quadrillion levels. Sensitivities in these instruments can be as high as 200 million counts per second per part per million with linear dynamic ranges up to eight orders of magnitude. With standards for only a few elements, rapid semiquantitative analysis of over 70 elements in an individual sample can be performed. Less than 20 years after its inception ICP-MS has shown to be applicable to several areas of science. These include geochemistry, the nuclear industry, environmental chemistry, clinical chemistry, the semiconductor industry, and forensic chemistry. In this introduction, the general attributes of ICP-MS will be discussed in terms of instrumentation and sample introduction. The advantages and disadvantages of current systems are presented. A detailed description of one method of sample introduction, laser ablation, is given. The paper also gives conclusions and suggestions for future work. Chapter 2, Quantitative analysis of solids by laser ablation inductively coupled plasma mass spectrometry using dried solution aerosols for calibration, has been removed for separate processing.

  11. Collaboration on Modeling of Ion Bernstein Wave Antenna Array and Coupling to Plasma on Tokamak Fusion Text Reactor. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Intrator, T.

    2000-06-01

    This proposal was peer reviewed and funded as a Collaboration on ''Low Phase Speed Radio Frequency Current Drive Experiments at the Tokamak Fusion Test Reactor''. The original plans we had were to carry out the collaboration proposal by including a post doctoral scientist stationed at PPPL. In response to a 60+% funding cut, all expenses were radically pruned. The post doctoral position was eliminated, and the Principal Investigator (T. Intrator) carried out the brunt of the collaboration. Visits to TFTR enabled T. Intrator to set up access to the TFTR computing network, database, and get familiar with the new antennas that were being installed in TFTR during an up to air. One unfortunate result of the budget squeeze that TFTR felt for its last year of operation was that the experiments that we specifically got funded to perform were not granted run time on TFTR., On the other hand we carried out some modeling of the electric field structure around the four strap direct launch Ion Bernstein Wave (IBW) antenna that was operated on TFTR. This turned out to be a useful exercise and shed some light on the operational characteristics of the IBW antenna and its coupling to the plasma. Because of this turn of events, the project was renamed ''Modeling of Ion Bernstein Wave Antenna Array and Coupling to Plasma on Tokamak Fusion Test Reactor''.

  12. Collaboration on Modeling of Ion Bernstein Wave Antenna Array and Coupling to Plasma on Tokamak Fusion Text Reactor. Final report

    International Nuclear Information System (INIS)

    Intrator, T.

    2000-01-01

    This proposal was peer reviewed and funded as a Collaboration on ''Low Phase Speed Radio Frequency Current Drive Experiments at the Tokamak Fusion Test Reactor''. The original plans we had were to carry out the collaboration proposal by including a post doctoral scientist stationed at PPPL. In response to a 60+% funding cut, all expenses were radically pruned. The post doctoral position was eliminated, and the Principal Investigator (T. Intrator) carried out the brunt of the collaboration. Visits to TFTR enabled T. Intrator to set up access to the TFTR computing network, database, and get familiar with the new antennas that were being installed in TFTR during an up to air. One unfortunate result of the budget squeeze that TFTR felt for its last year of operation was that the experiments that we specifically got funded to perform were not granted run time on TFTR., On the other hand we carried out some modeling of the electric field structure around the four strap direct launch Ion Bernstein Wave (IBW) antenna that was operated on TFTR. This turned out to be a useful exercise and shed some light on the operational characteristics of the IBW antenna and its coupling to the plasma. Because of this turn of events, the project was renamed ''Modeling of Ion Bernstein Wave Antenna Array and Coupling to Plasma on Tokamak Fusion Test Reactor''

  13. Ultra-sensitive quantification of lysozyme based on element chelate labeling and capillary electrophoresis-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Yang, MingWei; Wu, WeiHua; Ruan, YaJuan; Huang, LiMei; Wu, Zujian; Cai, Yong; Fu, FengFu

    2014-02-17

    In this study, an ultra-sensitive method for the quantification of lysozyme based on the Gd(3+) diethylenetriamine-N,N,N',N″,N″-pentaacetic acid labeling and capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICP-MS) was described. The Gd(3+)-tagged lysozyme was effectively separated by capillary electrophoresis (CE) and sensitively determined by inductively coupled plasma mass spectrometry (ICP-MS). Based on the gadolinium-tagging and CE-ICP-MS, the lysozyme was determined within 12 min with an extremely low detection limit of 3.89 attomole (3.89×10(-11) mol L(-1) for 100 nL of sample injection) and a RSDlysozyme in saliva samples with a recovery of 91-106%, suggesting that our method is sensitive and reliable. The success of the present method provides a new potential for the biological assays and sensitive detection of low-abundant proteins. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Development of a 1.5D plasma transport code for coupling to full orbit runaway electron simulations

    Science.gov (United States)

    Lore, J. D.; Del Castillo-Negrete, D.; Baylor, L.; Carbajal, L.

    2017-10-01

    A 1.5D (1D radial transport + 2D equilibrium geometry) plasma transport code is being developed to simulate runaway electron generation, mitigation, and avoidance by coupling to the full-orbit kinetic electron transport code KORC. The 1.5D code solves the time-dependent 1D flux surface averaged transport equations with sources for plasma density, pressure, and poloidal magnetic flux, along with the Grad-Shafranov equilibrium equation for the 2D flux surface geometry. Disruption mitigation is simulated by introducing an impurity neutral gas `pellet', with impurity densities and electron cooling calculated from ionization, recombination, and line emission rate coefficients. Rapid cooling of the electrons increases the resistivity, inducing an electric field which can be used as an input to KORC. The runaway electron current is then included in the parallel Ohm's law in the transport equations. The 1.5D solver will act as a driver for coupled simulations to model effects such as timescales for thermal quench, runaway electron generation, and pellet impurity mixtures for runaway avoidance. Current progress on the code and details of the numerical algorithms will be presented. Work supported by the US DOE under DE-AC05-00OR22725.

  15. Cobalamin speciation using reversed-phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Yanes, Enrique G.; Miller-Ihli, Nancy J.

    2004-01-01

    Micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry was optimized for the determination and separation of a mixture of cobalt containing species. Four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5'-deoxyadenosylcobalamin) representing the various forms of vitamin B12 as well as the harmful corrinoid analogue cobinamide dicyanide were separated using reversed-phase microcapillary chromatography with columns containing C18 packing material with a 2-μm particle size. Selection of organic solvents for the separation took into consideration compatibility with the inductively coupled plasma mass spectrometer being used for element specific detection. Optimized method conditions included use of a methanol gradient and make-up solution for the nebulizer. Some issues associated with dead volume were overcome by the extension of the gradient program. The total analysis time was 52 min. The column-to-column variability was evaluated and was found to be very reasonable (9% RSD on average), confirming that this method is rugged and that the technology should be easily transferred to other laboratories

  16. Vertically aligned Si nanocrystals embedded in amorphous Si matrix prepared by inductively coupled plasma chemical vapor deposition (ICP-CVD)

    Energy Technology Data Exchange (ETDEWEB)

    Nogay, G. [Department of Physics, Middle East Technical University (METU), Ankara 06800 (Turkey); Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Saleh, Z.M., E-mail: zaki.saleh@aauj.edu [Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Department of Physics, Arab American University–Jenin (AAUJ), Jenin, Palestine (Country Unknown); Özkol, E. [Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey); Department of Chemical Engineering, Middle East Technical University (METU), Ankara 06800 (Turkey); Turan, R. [Department of Physics, Middle East Technical University (METU), Ankara 06800 (Turkey); Center of Solar Energy Research and Application (GÜNAM), Middle East Technical University (METU), Ankara 06800 (Turkey)

    2015-06-15

    Highlights: • Inductively-coupled plasma is used for nanostructured silicon at room temperature. • Low temperature deposition allows device processing on various substrates. • Deposition pressure is the most effective parameter in controlling nanostructure. • Films consist of quantum dots in a-Si matrix and exhibit columnar vertical growth. • Films are porous to oxygen infusion along columnar grain boundaries. - Abstract: Vertically-aligned nanostructured silicon films are deposited at room temperature on p-type silicon wafers and glass substrates by inductively-coupled, plasma-enhanced chemical vapor deposition (ICPCVD). The nanocrystalline phase is achieved by reducing pressure and increasing RF power. The crystalline volume fraction (X{sub c}) and the size of the nanocrystals increase with decreasing pressure at constant power. Columnar growth of nc-Si:H films is observed by high resolution transmission electron microscopy (HRTEM) and scanning electron microscopy (SEM). The films exhibit cauliflower-like structures with high porosity that leads to slow but uniform oxidation after exposure to air at room temperature. Films deposited at low pressures exhibit photoluminescence (PL) signals that may be deconvoluted into three distinct Gaussian components: 760–810, 920–935, and 990–1000 nm attributable to the quantum confinement and interface defect states. Hydrogen dilution is manifested in significant enhancement of the PL, but it has little effect on the nanocrystal size and X{sub c}.

  17. Cobalamin speciation using reversed-phase micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yanes, Enrique G. E-mail: yanes@bhnrc.usda.gov; Miller-Ihli, Nancy J. E-mail: miller-ihli@bhnrc.usda.gov

    2004-06-18

    Micro-high-performance liquid chromatography interfaced to inductively coupled plasma mass spectrometry was optimized for the determination and separation of a mixture of cobalt containing species. Four cobalamin species (cyanocobalamin, hydroxocobalamin, methylcobalamin, and 5'-deoxyadenosylcobalamin) representing the various forms of vitamin B12 as well as the harmful corrinoid analogue cobinamide dicyanide were separated using reversed-phase microcapillary chromatography with columns containing C18 packing material with a 2-{mu}m particle size. Selection of organic solvents for the separation took into consideration compatibility with the inductively coupled plasma mass spectrometer being used for element specific detection. Optimized method conditions included use of a methanol gradient and make-up solution for the nebulizer. Some issues associated with dead volume were overcome by the extension of the gradient program. The total analysis time was 52 min. The column-to-column variability was evaluated and was found to be very reasonable (9% RSD on average), confirming that this method is rugged and that the technology should be easily transferred to other laboratories.

  18. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  19. Multi-elemental determination of trace elements in deep seawater by inductively coupled plasma mass spectrometry with resin preconcentration

    International Nuclear Information System (INIS)

    Sumida, Takashi; Nakazato, Tetsuya; Tao, Hiroaki

    2003-01-01

    A miniaturized column (ca. 3 mm i.d., 40 mm length), packed with a chelating resin (0.2 g) with iminodiacetic acid groups (Muromac A-1), was tested for the preconcentration of trace elements in seawater. After preconcentration, the column was washed with ammonium acetate buffer (pH 5.5) and water to remove the major elements, such as Ca and Mg, and was then eluted with 4 ml of 2 mol l -1 nitric acid. Twenty-six trace elements were determined by inductively coupled plasma mass spectrometry and inductively coupled plasma emission spectrometry. The necessary volume of the seawater sample was only 200 ml. The recoveries for most of the elements tested were over 90%, although those for Al, V and Th were around 70%. The trueness and precision were evaluated by analyzing a standard reference material of seawater (NASS-4, NRC Canada). The observed values obtained with the present method showed good agreement with the certified values. The present method was also applied to deep seawater samples collected at Muroto, Japan. A difference in the rare earth element pattern, especially the Ce anomaly, between the deep seawater sample and the surface seawater sample was observed, as well as the differences of the concentrations of many trace elements. (author)

  20. Direct covalent coupling of proteins to nanostructured plasma polymers: a route to tunable cell adhesion

    Czech Academy of Sciences Publication Activity Database

    Melnichuk, I.; Choukourov, A.; Bilek, M.; Weiss, A.; Vandrovcová, Marta; Bačáková, Lucie; Hanuš, J.; Kousal, J.; Shelemin, A.; Solař, P.; Slavínská, D.; Biederman, H.

    2015-01-01

    Roč. 351, Oct 1 (2015), s. 537-545 ISSN 0169-4332 R&D Projects: GA MZd(CZ) NT13297 Institutional support: RVO:67985823 Keywords : covalent binding * plasma polymers * MG-63 osteoblasts Subject RIV: CD - Macromolecular Chemistry Impact factor: 3.150, year: 2015

  1. Ionization of sputtered Ti, Al, and C coupled with plasma characterization in HiPIMS

    Czech Academy of Sciences Publication Activity Database

    Lundin, D.; Čada, Martin; Hubička, Zdeněk

    2015-01-01

    Roč. 24, č. 3 (2015), s. 035018 ISSN 0963-0252 R&D Projects: GA MŠk LH12043 EU Projects: European Commission(XE) 608800 - HIPPOCAMP Institutional support: RVO:68378271 Keywords : IPVD * HiPIMS * HPPMS * Langmuir probe * ion meter Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.808, year: 2015

  2. Derivation of the one component plasma fluid equation of state in strong coupling

    International Nuclear Information System (INIS)

    DeWitt, H.E.; Rosenfeld, Y.

    1979-01-01

    A variational calculation of the one component plasma energy using the hard sphere Percus-Yevick g(r) and the virial entropy gives U/NkT = a GAMMA + b GAMMAsup(1/4) + c + d/ GAMMAsup(1/4) + ... in agreement with the empirical fit to Monte Carlo data. (orig.)

  3. Afecto y elección de pareja en jóvenes de sectores populares de Cali Affection and couple election among teenagers from popular sectors of Cali

    Directory of Open Access Journals (Sweden)

    Fernando Urrea Giraldo

    2006-04-01

    Full Text Available Este artículo explora las lógicas de producción de afectos y elección de pareja en los jóvenes de sectores populares heterogéneos de la ciudad de Cali (Colombia, según factores de clase, género y raza. Sin pretender entrar directamente en la conyugalidad, de todos modos el texto sí incursiona en el asunto de la elección de pareja, bajo las restricciones del ciclo de vida adolescente y postadolescente de nuestro programa de investigación a través del noviazgo, eventualmente con la opción de cohabitar y tener una prole; de acuerdo con la información recogida a nivel de las entrevistas y los grupos focales. En segundo lugar, al tener la disposición de una información estadística a través de una serie de encuestas de hogares entre 1998 y el 2003 para Cali y la región urbana del Valle del Cauca, en donde se encuentra Cali, sobre población afrocolombiana y no afrocolombiana, hemos podido intentar una primera aproximación al fenómeno de la homogamia racial de los hogares completos (con presencia de cónyuge, estableciendo los nexos necesarios con los datos cualitativos para mirar desde una perspectiva macro social el comportamiento de esas lógicas en los grupos jóvenes. Por ello, los factores de clase, género y raza son vistos a través de la categoría de homogamia racial, en el sentido de acercarse a los constreñimientos sociales del ejercicio de la sexualidad, el afecto y el intento de conformación de uniones en la sociedad caleña.This article explores the affection and the couple election production logics among teenagers from heterogeneous popular sectors of Cali city (Colombia, according to class, gender and race factors. Without seeking to look directly into the conjugality, anyway the text enters in the matter of couple's election, under the restrictions of adolescent and post adolescent life cycle of our research program through the courtship, eventually with the option to cohabit and to have an offspring; in

  4. Evolution of the mean jet shape and dijet asymmetry distribution of an ensemble of holographic jets in strongly coupled plasma

    Science.gov (United States)

    Brewer, Jasmine; Rajagopal, Krishna; Sadofyev, Andrey; van der Schee, Wilke

    2018-02-01

    Some of the most important experimentally accessible probes of the quark- gluon plasma (QGP) produced in heavy ion collisions come from the analysis of how the shape and energy of sprays of energetic particles produced within a cone with a specified opening angle (jets) in a hard scattering are modified by their passage through the strongly coupled, liquid, QGP. We model an ensemble of back-to-back dijets for the purpose of gaining a qualitative understanding of how the shapes of the individual jets and the asymmetry in the energy of the pairs of jets in the ensemble are modified by their passage through an expanding cooling droplet of strongly coupled plasma, in the model in a holographic gauge theory that is dual to a 4+1-dimensional black-hole spacetime that is asymptotically anti-de Sitter (AdS). We build our model by constructing an ensemble of strings in the dual gravitational description of the gauge theory. We model QCD jets in vacuum using strings whose endpoints are moving "downward" into the gravitational bulk spacetime with some fixed small angle, an angle that represents the opening angle (ratio of jet mass to jet energy) that the QCD jet would have in vacuum. Such strings must be moving through the gravitational bulk at (close to) the speed of light; they must be (close to) null. This condition does not specify the energy distribution along the string, meaning that it does not specify the shape of the jet being modeled. We study the dynamics of strings that are initially not null and show that strings with a wide range of initial conditions rapidly accelerate and become null and, as they do, develop a similar distribution of their energy density. We use this distribution of the energy density along the string, choose an ensemble of strings whose opening angles and energies are distributed as in perturbative QCD, and show that we can then fix one of the two model parameters such that the mean jet shape for the jets in the ensemble that we have built

  5. Role of vibrationally excited HBr in a HBr/He inductively coupled plasma used for etching of silicon

    Science.gov (United States)

    Tinck, Stefan; Bogaerts, Annemie

    2016-06-01

    In this work, the role of vibrationally excited HBr (HBr(vib)) is computationally investigated for a HBr/He inductively coupled plasma applied for Si etching. It is found that at least 50% of all dissociations of HBr occur through HBr(vib). This additional dissociation pathway through HBr(vib) makes the plasma significantly more atomic. It also results in a slightly higher electron temperature (i.e. about 0.2 eV higher compared to simulation results where HBr(vib) is not included), as well as a higher gas temperature (i.e. about 50 K higher than without including HBr(vib)), due to the enhanced Franck-Condon heating through HBr(vib) dissociation, at the conditions investigated. Most importantly, the calculated etch rate with HBr(vib) included in the model is a factor 3 higher than in the case without HBr(vib), due to the higher fluxes of etching species (i.e. H and Br), while the chemical composition of the wafer surface shows no significant difference. Our calculations clearly show the importance of including HBr(vib) for accurate modeling of HBr-containing plasmas.

  6. Measurements of neutral and ion composition, neutral temperature, and electron energy distribution function in a CF4 inductively coupled plasma

    International Nuclear Information System (INIS)

    Singh, Harmeet; Coburn, J.W.; Graves, David B.

    2001-01-01

    In this article, we present comprehensive measurements of the neutral number densities, ion number densities, and the electron energy distribution function in a CF 4 inductively coupled plasma at pressures between 1 and 30 mTorr, and deposited powers between 150 and 550 W. High degrees of dissociation are observed at the lower pressures. We believe this is a result of the large electron temperature at the lower pressures. The measurements of all the dominant radical and stable neutral species using appearance potential mass spectrometry allows the estimation of the neutral temperature at the neutral sampling aperture. The neutral temperature is also estimated from the change in the number density of a trace amount of argon added to CF 4 when the plasma is turned on. Neutral temperatures up to 930 K are measured at the sampling aperture. The increase in neutral temperature with power at a constant pressure results in a decrease in the total neutral number density at a constant pressure. The electron temperature is sensitive to the neutral number density, especially at low densities. This leads to a significant increase in the electron temperature with power, resulting in the higher degrees of dissociation observed at low pressures. The number densities of radicals and their corresponding ions are generally strongly correlated in the plasma. We show indirect evidence for large surface loss coefficients for C and CF radicals

  7. Laser and Plasma Parameters for Laser Pulse Amplification by Stimulated Brillouin Backscattering in the Strong Coupling Regime

    Science.gov (United States)

    Gangolf, Thomas; Blecher, Marius; Bolanos, Simon; Lancia, Livia; Marques, Jean-Raphael; Cerchez, Mirela; Prasad, Rajendra; Aurand, Bastian; Loiseau, Pascal; Fuchs, Julien; Willi, Oswald

    2017-10-01

    In the ongoing quest for novel techniques to obtain ever higher laser powers, plasma amplification has drawn much attention, benefiting from the fact that a plasma can sustain much higher energy densities than a solid state amplifier. As a plasma process, Stimulated Brillouin Backscattering in the strong coupling regime (sc-SBS) can be used to transfer energy from one laser pulse (pump) to another (seed), by a nonlinear ion oscillation forced by the pump laser. Here, we report on experimental results on amplification by sc-SBS using the ARCTURUS Ti:Sapphire multi-beam laser system at the University of Duesseldorf, Germany. Counter-propagating in a supersonic Hydrogen gas jet target, an ultrashort seed pulse with a pulse duration between 30 and 160 fs and an energy between 1 and 12 mJ was amplified by a high-energy pump pulse (1.7 ps, 700 mJ). For some of the measurements, the gas was pre-ionized with a separate laser pulse (780 fs, 460 mJ). Preliminary analysis shows that the amplification was larger for the longer seed pulses, consistent with theoretical predictions.

  8. Kinetic Temperature and Electron Density Measurement in an Inductively Coupled Plasma Torch using Degenerate Four-Wave Mixing

    Science.gov (United States)

    Schafer, Julia; Lyons, Wendy; Tong, WIlliam G.; Danehy, Paul M.

    2008-01-01

    Laser wave mixing is presented as an effective technique for spatially resolved kinetic temperature measurements in an atmospheric-pressure radio-frequency inductively-coupled plasma. Measurements are performed in a 1 kW, 27 MHz RF plasma using a continuous-wave, tunable 811.5-nm diode laser to excite the 4s(sup 3)P2 approaches 4p(sup 3)D3 argon transition. Kinetic temperature measurements are made at five radial steps from the center of the torch and at four different torch heights. The kinetic temperature is determined by measuring simultaneously the line shape of the sub-Doppler backward phase-conjugate degenerate four-wave mixing and the Doppler-broadened forward-scattering degenerate four-wave mixing. The temperature measurements result in a range of 3,500 to 14,000 K+/-150 K. Electron densities measured range from 6.1 (+/-0.3) x 10(exp 15)/cu cm to 10.1 (+/-0.3) x 10(exp 15)/cu cm. The experimental spectra are analyzed using a perturbative treatment of the backward phase-conjugate and forward-geometry wave-mixing theory. Stark width is determined from the collisional broadening measured in the phase-conjugate geometry. Electron density measurements are made based on the Stark width. The kinetic temperature of the plasma was found to be more than halved by adding deionized water through the nebulizer.

  9. Analytical performance of a low-gas-flow torch optimized for inductively coupled plasma atomic emission spectrometry

    Science.gov (United States)

    Montaser, A.; Huse, G.R.; Wax, R.A.; Chan, S.-K.; Golightly, D.W.; Kane, J.S.; Dorrzapf, A.F.

    1984-01-01

    An inductively coupled Ar plasma (ICP), generated in a lowflow torch, was investigated by the simplex optimization technique for simultaneous, multielement, atomic emission spectrometry (AES). The variables studied included forward power, observation height, gas flow (outer, intermediate, and nebulizer carrier) and sample uptake rate. When the ICP was operated at 720-W forward power with a total gas flow of 5 L/min, the signal-to-background ratios (S/B) of spectral lines from 20 elements were either comparable or inferior, by a factor ranging from 1.5 to 2, to the results obtained from a conventional Ar ICP. Matrix effect studies on the Ca-PO4 system revealed that the plasma generated in the low-flow torch was as free of vaporizatton-atomizatton interferences as the conventional ICP, but easily ionizable elements produced a greater level of suppression or enhancement effects which could be reduced at higher forward powers. Electron number densities, as determined via the series until line merging technique, were tower ht the plasma sustained in the low-flow torch as compared with the conventional ICP. ?? 1984 American Chemical Society.

  10. Modeling, fabrication and plasma actuator coupling of flexible pressure sensors for flow separation detection and control in aeronautical applications

    International Nuclear Information System (INIS)

    Francioso, L; De Pascali, C; Siciliano, P; Pescini, E; De Giorgi, M G

    2016-01-01

    Preventing the flow separation could enhance the performance of propulsion systems and future civil aircraft. To this end, a fast detection of boundary layer separation is mandatory for a sustainable and successful application of active flow control devices, such as plasma actuators. The present work reports on the design, fabrication and functional tests of low-cost capacitive pressure sensors coupled with dielectric barrier discharge (DBD) plasma actuators to detect and then control flow separation. Finite element method (FEM) simulations were used to obtain information on the deflection and the stress distribution in different-shaped floating membranes. The sensor sensitivity as a function of the pressure load was also calculated by experimental tests. The results of the calibration of different capacitive pressure sensors are reported in this work, together with functional tests in a wind tunnel equipped with a curved wall plate on which a DBD plasma actuator was mounted to control the flow separation. The flow behavior was experimentally investigated by particle image velocimetry (PIV) measurements. Statistical and spectral analysis, applied to the output signals of the pressure sensor placed downstream of the profile leading edge, demonstrated that the sensor is able to discriminate different ionic wind velocity and turbulence conditions. The sensor sensitivity in the 0–100 Pa range was experimentally measured and it ranged between 0.0030 and 0.0046 pF Pa −1 for the best devices. (paper)

  11. Modeling, fabrication and plasma actuator coupling of flexible pressure sensors for flow separation detection and control in aeronautical applications

    Science.gov (United States)

    Francioso, L.; De Pascali, C.; Pescini, E.; De Giorgi, M. G.; Siciliano, P.

    2016-06-01

    Preventing the flow separation could enhance the performance of propulsion systems and future civil aircraft. To this end, a fast detection of boundary layer separation is mandatory for a sustainable and successful application of active flow control devices, such as plasma actuators. The present work reports on the design, fabrication and functional tests of low-cost capacitive pressure sensors coupled with dielectric barrier discharge (DBD) plasma actuators to detect and then control flow separation. Finite element method (FEM) simulations were used to obtain information on the deflection and the stress distribution in different-shaped floating membranes. The sensor sensitivity as a function of the pressure load was also calculated by experimental tests. The results of the calibration of different capacitive pressure sensors are reported in this work, together with functional tests in a wind tunnel equipped with a curved wall plate on which a DBD plasma actuator was mounted to control the flow separation. The flow behavior was experimentally investigated by particle image velocimetry (PIV) measurements. Statistical and spectral analysis, applied to the output signals of the pressure sensor placed downstream of the profile leading edge, demonstrated that the sensor is able to discriminate different ionic wind velocity and turbulence conditions. The sensor sensitivity in the 0-100 Pa range was experimentally measured and it ranged between 0.0030 and 0.0046 pF Pa-1 for the best devices.

  12. Numerical Simulation of Plasma-Dynamical Processes in the Technological Inductively Coupled RF Plasmatron with Gas Cooling

    Directory of Open Access Journals (Sweden)

    Yu. M. Grishin

    2016-01-01

    Full Text Available The electrodeless inductively coupled RF plasmatron (ICP torches became widely used in various fields of engineering, science and technology. Presently, owing to development of new technologies to produce very pure substances, nanopowders, etc., there is a steadily increasing interest in the induction plasma. This generates a need for a broad range of theoretical and experimental studies to optimize the design and technological parameters of different ICP equipment.The paper presents a numerical model to calculate parameters of inductively coupled RF plasmatron with gas-cooling flow. A finite volume method is used for a numerical solution of a system of Maxwell's and heat transfer equations in the application package ANSYS CFX (14.5. The pseudo-steady approach to solving problems is used.A numerical simulation has been computed in the application package ANSYS CFX (14.5 for a specific design option of the technological ICP, which has a three-coils inductor and current amplitude in the range J к = 50-170 A (3 MHz. The pure argon flows in the ICP. The paper discusses how the value of discharge current impacts on the thermodynamic parameters (pressure, temperature and the power energy in discharge zone. It shows that the ICP can generate a plasma stream with a maximum temperature of about 10 kK and an output speed of 10-15 m/s. The work determines a length of the plasma stream with a weight average temperature of more than 4 kK. It has been found that in order to keep the quartz walls in normal thermal state, the discharge current amplitude should not exceed 150 A. The paper shows the features of the velocity field distribution in the channel of the plasma torch, namely, the formation of vortex in the position of the first coil. The results obtained are important for calculating the dynamics of heating and evaporation of quartz particles in the manufacturing processes for plasma processing of quartz concentrate into high-purity quartz and

  13. Specific determination of intact cisplatin and monohydrated cisplatin in human plasma and culture medium ultrafiltrates using HPLC on-line with inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Bell, Deanna N; Liu, Johnson J; Tingle, Malcolm D; McKeage, Mark J

    2006-06-06

    We have developed a specific assay for cisplatin in human plasma ultrafiltrate (PUF) and cell culture medium ultrafiltrate (MUF) using HPLC on-line with inductively coupled plasma mass spectrometry (ICP-MS). Separation of cisplatin (6 min) and monohydrated cisplatin (12 min) was achieved using a muBondapak C(18) column (Waters) and a mobile phase (0.075 mM sodium dodecyl sulfate and 3% methanol, adjusted to pH 2.5 with triflic acid) pumped at a flow rate of 0.5 mL/min. The analytes were detected with little background interference by ICP-MS monitoring of platinum masses (m/z 194/195). Calibration curves were linear over three orders of magnitude (0.05-8 microM) and the limit of quantitation was 0.1 microM. Intra- and inter-assay accuracy (range 91.6-113%) and precision (range 1.00-12.3%) were acceptable for PUF and MUF. The method was applied to determining cisplatin during ex vivo incubation of the drug in whole human blood at 37 degrees C. In conclusion, a specific, sensitive and reliable HPLC-ICP-MS assay has been established for determining intact cisplatin in PUF and MUF.

  14. Generation of runaway electrons during deterioration of lower hybrid power coupling in lower hybrid current drive plasmas in the HT-7 tokamak

    International Nuclear Information System (INIS)

    Chen, Z Y; Ju, H J; Zhu, J X; Li, M; Cai, W D; Liang, H F; Wan, B N; Shi, Y J; Xu, H D

    2009-01-01

    Efficient coupling of lower hybrid (LH) power from the wave launcher to the plasma is a very important issue in lower hybrid current drive (LHCD) experiments. The large unbalanced reflections in the grill trigger the LH protection system, which will trip the power, resulting in the reduction of the coupled LH power. The generation of runaway electrons has been investigated in LHCD plasmas with deterioration of LH coupling in the HT-7 tokamak. The deterioration of LH coupling results in an increase of the loop voltage and a more energetic fast electron population. These two effects favor the generation of a runaway population. It is found that most of the fast electrons generated by LH waves through parallel electron Landau damping were converted into a runaway population through the acceleration from the toroidal electric field when significant deterioration of LH coupling occurs.

  15. Numerical study of capacitive coupled HBr/Cl2 plasma discharge for dry etch applications

    Science.gov (United States)

    Gul, Banat; Ahmad, Iftikhar; Zia, Gulfam; Aman-ur-Rehman

    2016-09-01

    HBr/Cl2 plasma discharge is investigated to study the etchant chemistry of this discharge by using the self-consistent fluid model. A comprehensive set of gas phase reactions (83 reactions) including primary processes such as excitation, dissociation, and ionization are considered in the model along with 24 species. Our findings illustrate that the densities of neutral species (i.e., Br, HCl, Cl, H, and H2) produced in the reactor are higher than charged species (i.e., Cl2+, Cl-, HBr+, and Cl+). Density profile of neutral and charged species followed bell shaped and double humped distributions, respectively. Increasing Cl2 fraction in the feedback gases (HBr/Cl2 from 90/10 to 10/90) promoted the production of Cl, Cl+, and Cl2+ in the plasma, indicating that chemical etching pathway may be preferred at high Cl-environment. These findings pave the way towards controlling/optimizing the Si-etching process.

  16. Ionization cross section for a strongly coupled partially ionized hydrogen plasma: variable phase approach

    Energy Technology Data Exchange (ETDEWEB)

    Baimbetov, F B; Kudyshev, Z A [Department of Physics, Al-Farabi Kazakh National University, 050012 Almaty (Kazakhstan)], E-mail: Fazylhan.Baimbetov@kaznu.kz, E-mail: Z.Kudyshev@mail.ru

    2009-05-29

    In the present work an electron impact ionization cross section is considered. The electron impact ionization cross section is calculated with the help of a variable phase approach to potential scattering. The Calogero equation is numerically solved, based on a pseudopotential model of interaction between partially ionized plasma particles, which accounts for correlation effects. As a result, scattering phase shifts are obtained. On the basis of the scattering phase shifts, the ionization cross section is calculated.

  17. Gaseous phase benzene decomposition by non-thermal plasma coupled with nano titania catalyst

    International Nuclear Information System (INIS)

    Zhu, T.; Li, J.; Jin, Y. Q.; Liang, Y. H.; Ma, G. D.

    2009-01-01

    Synergistic effect of atmospheric non-thermal plasma generated by dielectric barrier discharge and nano titania photo catalyst for benzene decomposition was tested. The paper indicated the effect of photo catalyst on removal efficiency of benzene, the compare of photo catalyst characteristic in different high temperatures by heat treatment, analysis of by-products. The results showed that the effect of degradation was visible by added photo catalyst in the plasma reactor. When concentration of benzene was 600 mg/m 3 and electric field strength was 10 kV/cm, the removal efficiency of benzene was increased up to 81 % without photo catalyst. At the same condition, the removal efficiency was increased to 15 % higher with photo catalyst. Nano titania crystal was anatase crystal in 450 d eg C heat treatment which is best for benzene removal. The plasma reactor packed with photo catalyst shows a better selectivity of carbon dioxide than that without photo catalyst. By-products are mostly carbon dioxide, water and a small quantity of carbon monoxide

  18. Availability of zinc from infant formula by in vitro methods (solubility and dialyzability) and size-exclusion chromatography coupled to inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Gomez, Beatriz Gomez; Perez-Corona, M Teresa; Madrid, Yolanda

    2016-12-01

    Zinc bioaccessibility from infant formula was estimated by in vitro methods (solubility and dialyzability) and size-exclusion chromatography (SEC) coupled to inductively coupled plasma-mass spectrometry (ICP-MS). Infant formula samples were first characterized in terms of Zn bound to lipids and proteins and Zn distribution in the aqueous soluble protein fraction. We found that Zn is not incorporated into the lipid fraction of the samples, being mainly associated with the protein fraction (around 100%). Fractionation of Zn-containing proteins in the soluble protein fraction was achieved by SEC-ICP-MS after performing protein extraction with a solution of 100mM (pH 6.8) Tris-HCl. The percentages of zinc in the soluble protein fraction in the soy-based and lactose-free infant formula were very low, around 7 and 24%, respectively, whereas the content of Zn in the soluble protein fraction of milk-based formula was around 90%. By SEC-ICP-MS, we found that Zn is associated with low-molecular weight compounds (around 10kDa) in all the infant formulas tested. The percentages of Zn estimated in the in vitro gastrointestinal digests of the infant formula ranged from 30 to 70% and from 1 to 10% for solubility and dialyzability assays, respectively. The dialyzability test resulted in lower than expected scores, as SEC-ICP-MS analysis of the gastrointestinal extracts revealed that Zn is bound to biomolecules with a molecular weight ranging from 1 to 7kDa, which suggests that dialysis data should be interpreted with caution. Speciation studies are a valuable tool for establishing availability of nutrients and for validating data from dialyzable in vitro methods. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Shear viscosity of strongly coupled N = 4 supersymmetric Yang-Mills plasma.

    Science.gov (United States)

    Policastro, G; Son, D T; Starinets, A O

    2001-08-20

    Using the anti-de Sitter/conformal field theory correspondence, we relate the shear viscosity eta of the finite-temperature N = 4 supersymmetric Yang-Mills theory in the large N, strong-coupling regime with the absorption cross section of low-energy gravitons by a near-extremal black three-brane. We show that in the limit of zero frequency this cross section coincides with the area of the horizon. From this result we find eta = pi / 8N(2)T3. We conjecture that for finite 't Hooft coupling g(2)(YM)N the shear viscosity is eta = f(g(2)(YM)N)N2T3, where f(x) is a monotonic function that decreases from O(x(-2)ln(-1)(1/x)) at small x to pi/8 when x-->infinity.

  20. Calibration strategy for semi-quantitative direct gas analysis using inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Gerdes, Kirk; Carter, Kimberly E.

    2011-01-01

    A process is described by which an ICP-MS equipped with an Octopole Reaction System (ORS) is calibrated using liquid phase standards to facilitate direct analysis of gas phase samples. The instrument response to liquid phase standards is analyzed to produce empirical factors relating ion generation and transmission efficiencies to standard operating parameters. Empirical factors generated for liquid phase samples are then used to produce semi-quantitative analysis of both mixed liquid/gas samples and pure gas samples. The method developed is similar to the semi-quantitative analysis algorithms in the commercial software, which have here been expanded to include gas phase elements such as Xe and Kr. Equations for prediction of relative ionization efficiencies and isotopic transmission are developed for several combinations of plasma operating conditions, which allows adjustment of limited parameters between liquid and gas injection modes. In particular, the plasma temperature and electron density are calculated from comparison of experimental results to the predictions of the Saha equation. Comparisons between operating configurations are made to determine the robustness of the analysis to plasma conditions and instrument operating parameters. Using the methods described in this research, the elemental concentrations in a liquid standard containing 45 analytes and treated as an unknown sample were quantified accurately to ± 50% for most elements using 133 Cs as a single internal reference. The method is used to predict liquid phase mercury within 12% of the actual concentration and gas phase mercury within 28% of the actual concentration. The results verify that the calibration method facilitates accurate semi-quantitative, gas phase analysis of metal species with sufficient sensitivity to quantify metal concentrations lower than 1 ppb for many metallic analytes.

  1. Asymmetrical flow field-flow fractionation coupled to inductively coupled plasma mass spectrometry for sizing SeNPs for packaging applications

    Science.gov (United States)

    Palomo-Siguero, María; Vera, Paula; Echegoyen, Yolanda; Nerin, Cristina; Cámara, Carmen; Madrid, Yolanda

    2017-06-01

    This paper describes the application of Asymmetrical Flow Field-Flow Fractionation (AF4) coupled to diode array detector (DAD) and inductively coupled plasma mass spectrometry (AF4-UV-ICP-MS) to characterize selenium nanoparticles (SeNPs) in an aqueous acrylic adhesive to be used in a multilayer food packaging material. SeNPs were synthesized using a solution-phase approach based on the reduction of selenite with ascorbic acid in presence of different stabilizers compatible with food industry such as polysaccharides (chitosan (poly(D-glucosamine) and hydroxyethylcellulose (HEC)) and non-ionic surfactants (Triton X-100 (t-octylphenoxypolyethoxyethanol), 2,4,7,9-tetramethyl 5decyne-4,7-diol ethoxylate, and isotridecanol ethoxylate). Several parameters such as pH, ascorbic acid and stabilizers concentration, and compatibility of the stabilizer with the adhesive were evaluated. SeNPs suspensions with spherical morphology were obtained except when isotridecanol ethoxylate was employed which provides SeNPs with a nanorod morphology. AF4-DAD-ICP-MS was further applied for sizing the different SeNPs preparations. DAD was used as detector for selecting the best AF4 separation conditions before coupling to ICP-MS to ensure unequivocal identification of NPs. AF4 calibration with polystyrene latex (PSL) beads of known sizes allowed size determination of the different SeNPs. The following estimated hydrodynamic sizes (expressed as the mean ± standard deviation, n = 6 replicates) were found: chitosan-SeNPs- (26 ± 3 nm), TritonX100-SeNPs (22 ± 10 nm) HEC- SeNPs (91 ± 8 nm) and 2,4,7,9-tetramethyl 5decyne-4,7-diol ethoxylate- SeNPs (59 ± 4 nm). The proposed methodology was successfully applied to the characterization in terms of size of aqueous acrylic adhesives containing SeNPs Results from AF4-ICP-MS and TEM shown that only those SeNPs obtained with non-ionic surfactants and HEC were compatible with the adhesive. The results reported here evidence the usefulness of AF4-ICP

  2. Determination of Tributyltin in Seafood Based on Magnetic Molecularly Imprinted Polymers Coupled with High-Performance Liquid Chromatography-Inductively Coupled Plasma Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hua Yang

    2017-01-01

    Full Text Available In this study, Fe3O4 was adopted as a carrier for surface molecular imprinting with two-stage polymerization. First, the functional monomer (methacrylic acid, MAA was modified on the surface of Fe3O4, which was then polymerized with the template molecule (tributyltin, TBT, cross linking agent (ethylene glycol dimethacrylate, EGDMA, and porogen (acetonitrile, hereby successfully preparing Fe3O4@MIPs prone to specifically identify TBT. The physical properties of Fe3O4@MIPs were then characterized, and adsorption and selection capacities were also assessed. Compared with conventional imprinting polymers, this magnetic molecular imprinting polymer (MIP displayed significantly increased and more specific adsorption. Meanwhile, its pretreatment was simpler and faster due to magnetic separation characteristics. Using magnetic MIPs as adsorbents for enrichment and separation, detection limit, recovery rate, and linear range were 1.0 ng g−1, 79.74–95.72%, and 5 ng g−1~1000 ng g−1, respectively, for a number of seafood samples. High-performance liquid chromatography-inductively coupled plasma mass spectrometry (HPLC-ICP-MS was used to analyze Tegillarca granosa, mussels, large yellow croaker, and other specimens, with recovery rates of 79.74–95.72% and RSD of 1.3%–4.7%. Overall, this method has a shorter total analysis time, lower detection limit, and wider linear range and can be more effectively applied to determine MAA in seawater and seafood.

  3. Determination of low cadmium concentrations in wine by on-line preconcentration in a knotted reactor coupled to an inductively coupled plasma optical emission spectrometer with ultrasonic nebulization

    Energy Technology Data Exchange (ETDEWEB)

    Lara, R.F. [Inst. de Investigaciones Mineras, Universidad Nacional de San Juan (Argentina); Wuilloud, R.G.; Salonia, J.A. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Olsina, R.A.; Martinez, L.D. [Dept. of Analytical Chemistry, National University of San Luis (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET) (Argentina)

    2001-12-01

    An on-line cadmium preconcentration and determination system implemented with inductively coupled plasma optical emission spectrometry (ICP-OES) associated to flow injection (FI) with ultrasonic nebulization system (USN) was studied. The cadmium was retained as the cadmium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol, Cd-(5-Br-PADAP), complex, at pH 9.5. The cadmium complex was removed from the knotted reactor (KR) with 3.0 mol/L nitric acid. A total enhancement factor of 216 was obtained with respect to ICP-OES using pneumatic nebulization (12 for USN and 18 for KR) with a preconcentration time of 60 s. The value of the detection limit for the preconcentration of 5 mL of sample solution was 5 ng/L. The precision for 10 replicate determinations at the 5 {mu}g/L Cd level was 2.9% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for cadmium was linear with a correlation coefficient of 0.9998 at levels near the detection limits up to at least 1000 {mu}g/L. The method was successfully applied to the determination of cadmium in wine samples. (orig.)

  4. Magnetic immunoassay coupled with inductively coupled plasma mass spectrometry for simultaneous quantification of alpha-fetoprotein and carcinoembryonic antigen in human serum

    Science.gov (United States)

    Zhang, Xing; Chen, Beibei; He, Man; Zhang, Yiwen; Xiao, Guangyang; Hu, Bin

    2015-04-01

    The absolute quantification of glycoproteins in complex biological samples is a challenge and of great significance. Herein, 4-mercaptophenylboronic acid functionalized magnetic beads were prepared to selectively capture glycoproteins, while antibody conjugated gold and silver nanoparticles were synthesized as element tags to label two different glycoproteins. Based on that, a new approach of magnetic immunoassay-inductively coupled plasma mass spectrometry (ICP-MS) was established for simultaneous quantitative analysis of glycoproteins. Taking biomarkers of alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) as two model glycoproteins, experimental parameters involved in the immunoassay procedure were carefully optimized and analytical performance of the proposed method was evaluated. The limits of detection (LODs) for AFP and CEA were 0.086 μg L- 1 and 0.054 μg L- 1 with the relative standard deviations (RSDs, n = 7, c = 5 μg L- 1) of 6.5% and 6.2% for AFP and CEA, respectively. Linear range for both AFP and CEA was 0.2-50 μg L- 1. To validate the applicability of the proposed method, human serum samples were analyzed, and the obtained results were in good agreement with that obtained by the clinical chemiluminescence immunoassay. The developed method exhibited good selectivity and sensitivity for the simultaneous determination of AFP and CEA, and extended the applicability of metal nanoparticle tags based on ICP-MS methodology in multiple glycoprotein quantifications.

  5. Theoretical and experimental studies of a planar inductive coupled rf plasma source as the driver in simulator facility (ISTAPHM) of interactions of waves with the edge plasma on tokamaks

    Science.gov (United States)

    Ghanei, V.; Nasrabadi, M. N.; Chin, O.-H.; Jayapalan, K. K.

    2017-11-01

    This research aims to design and build a planar inductive coupled RF plasma source device which is the driver of the simulator project (ISTAPHM) of the interactions between ICRF Antenna and Plasma on tokamak by using the AMPICP model. For this purpose, a theoretical derivation of the distribution of the RF magnetic field in the plasma-filled reactor chamber is presented. An experimental investigation of the field distributions is described and Langmuir measurements are developed numerically. A comparison of theory and experiment provides an evaluation of plasma parameters in the planar ICP reactor. The objective of this study is to characterize the plasma produced by the source alone. We present the results of the first analysis of the plasma characteristics (plasma density, electron temperature, electron-ion collision frequency, particle fluxes and their velocities, stochastic frequency, skin depth and electron energy distribution functions) as function of the operating parameters (injected power, neutral pressure and magnetic field) as measured with fixed and movable Langmuir probes. The plasma is currently produced only by the planar ICP. The exact goal of these experiments is that the produced plasma by external source can exist as a plasma representative of the edge of tokamaks.

  6. An efficient spectrofluorimetric method adopts doxazosin, terazosin and alfuzosin coupling with orthophthalaldehyde: Application in human plasma

    Science.gov (United States)

    Omar, Mahmoud A.; Mohamed, Abdel-Maaboud I.; Derayea, Sayed M.; Hammad, Mohamed A.; Mohamed, Abobakr A.

    2018-04-01

    A new, selective and sensitive spectrofluorimetric method was designed for the quantitation of doxazosin (DOX), terazosin (TER) and alfuzosin (ALF) in their dosage forms and human plasma. The method adopts efficient derivatization of the studied drugs with ortho-phthalaldehyde (OPA), in the presence of 2-mercaptoethanol in borate buffer (pH 9.7) to generate a highly fluorescent isoindole derivatives, which can strongly enhance the fluorescence intensities of the studied drugs, allowing their sensitive determination at 430 nm after excitation at 337 nm. The fluorescence-concentration plots were rectilinear over the ranges (10.0-400.0) ng/mL. Detection and quantification limits were found to be (0.52-3.88) and (1.59-11.76) ng/mL, respectively. The proposed method was validated according to ICH guidelines, and successfully applied for the determination of pharmaceutical preparations of the studied drugs. Moreover, the high sensitivity of the proposed method permits its successful application to the analysis of the studied drugs in spiked human plasma with % recovery (96.12 ± 1.34-100.66 ± 0.57, n = 3). A proposal for the reaction mechanism was presented.

  7. Conical Torch: The Next-Generation Inductively Coupled Plasma Source for Spectrochemical Analysis.

    Science.gov (United States)

    Alavi, Sina; Khayamian, Taghi; Mostaghimi, Javad

    2018-03-06

    A completely new ICP torch for optical/mass spectrometry is introduced with a conical geometry leading to significant reduction in gas and power consumption. As a new holistic methodology, the torch has been designed on the basis of fluid flow patterns, heat transfer, plasma physics, and analytical performance. Computer simulations, capable of accounting for magneto-hydrodynamic effects, have been used to optimize torch geometry. The result is a "conical" torch with up to 70% reduction in argon flow and more than 4 times power density compared with traditional "cylindrical" torches. Based on experimental measurements, these features lead to a stable plasma with 1000-1700K higher excitation/rotational temperature and a 5-fold increase in electron number density compared to common torches. Interferences from easily ionizable elements (e.g., Na) are also observed to be minimized due to 3 times higher robustness (Mg II/Mg I ratio). Eventually, analytical parameters including detection limits for multielement analysis indicate comparable/better performance of the new torch in comparison with conventional torches.

  8. An engineering and economic analysis: Inductively coupled plasma mobile treatment of hazardous waste

    International Nuclear Information System (INIS)

    Detering, B.A.; McLlwain, M.E.

    1997-10-01

    This analysis considers the engineering and economic viability of an rf-plasma, mobile treatment process for remediation of hazardous waste located at remote sites in Alaska. A simple engineering process flowsheet is used to define the elements associated with the process and to identify major pieces of equipment. The proposed flowsheet and equipment are used to estimate capital and operational costs for four separate processing cases. These cases explore various operational situations, including moving equipment to a remote site, transporting wastes to a base site, and varying operational periods. Some cases consider variations in fuel costs known to exist across Alaska. Operational costs, capital equipment costs, and revenues are used to calculate pro-forma income statements. These income statements are used to predict economic viability. Based on the economic viability, the analysis suggests that processing of hydrocarbon-contaminated soils is more profitable when performed at remote sites as compared to at a home base. Processing of poly-chloro-biphenyl (PCB)-contaminated oil at a stationary site is more profitable as compared to remote treatment due to the cost of transporting the equipment. Over the range of fuel prices considered, higher fuel costs increase the per unit treatment price by ten percent. Based on the results of this analysis, an rf-plasma based process appears to be economically viable for remote treatment of hydrocarbon-contaminated soil, but less viable for treatment of PCB-contaminated oil

  9. Aluminium content of some processed foods, raw materials and food additives in China by inductively coupled plasma-mass spectrometry.

    Science.gov (United States)

    Deng, Gui-Fang; Li, Ke; Ma, Jing; Liu, Fen; Dai, Jing-Jing; Li, Hua-Bin

    2011-01-01

    The level of aluminium in 178 processed food samples from Shenzhen city in China was evaluated using inductively coupled plasma-mass spectrometry. Some processed foods contained a concentration of up to 1226 mg/kg, which is about 12 times the Chinese food standard. To establish the main source in these foods, Al levels in the raw materials were determined. However, aluminium concentrations in raw materials were low (0.10-451.5 mg/kg). Therefore, aluminium levels in food additives used in these foods was determined and it was found that some food additives contained a high concentration of aluminium (0.005-57.4 g/kg). The results suggested that, in the interest of public health, food additives containing high concentrations of aluminium should be replaced by those containing less. This study has provided new information on aluminium levels in Chinese processed foods, raw materials and a selection of food additives.

  10. Accuracy and Precision in Elemental Analysis of Environmental Samples using Inductively Coupled Plasma-Atomic Emission Spectrometry

    International Nuclear Information System (INIS)

    Quraishi, Shamsad Begum; Chung, Yong-Sam; Choi, Kwang Soon

    2005-01-01

    Inductively Coupled Plasma-Atomic Emission Spectrometry followed by micro-wave digestion have been performed on different environmental Certified Reference Materials (CRMs). Analytical results show that accuracy and precision in ICP-AES analysis were acceptable and satisfactory in case of soil and hair CRM samples. The relative error of most of the elements in these two CRMs is within 10% with few exceptions and coefficient of variation is also less than 10%. Z-score as an analytical performance was also within the acceptable range (±2). ICP-AES was found as an inadequate method for Air Filter CRM due to incomplete dissolution, low concentration of elements and very low mass of the sample. However, real air filter sample could have been analyzed with high accuracy and precision by increasing sample mass during collection. (author)

  11. Spectrochemical pure cerium dioxide preparation and its quality control by inductively coupled plasma and mass spectrometry (ICP/MS)

    International Nuclear Information System (INIS)

    Da Silva Queiroz, C.A.; De Souza, J.E.; Abrao, A.

    1998-01-01

    Full text: A simple and economic procedure for the purification until 500 g CeO 2 batch is presented. The purified material will be used as spectrochemical standard. It is obtained by association of the fractional precipitation technique in the system REC 3 /H 2 O 2 /NH 4 OH to enrich the cerium up to 90% and then refined by ion exchange up to 99.9% CeO2. The 99,9% CeO 2 warranty control of purity was accomplished by inductively coupled plasma and mass spectrometry (ICP/ MS) and compared with activation analysis data, exhibiting impurities traces of same values of the international spec pure standard. The following results (average values) for the contaminant rare earths are (ppm):La(36), Pr(19), Nd(161), Sm(11), Eu(5,3),Gd(113),Tb(89),Dy(2),Ho(0.05),Er(1), Tm(0), Yb(11), Lu (19) and Y(2.1), respectively

  12. Application of a high resolution inductively coupled plasma mass spectrometer to the measurement of long-lived radionuclides

    International Nuclear Information System (INIS)

    Kim, C.-K.; Seki, Riki; Morita, Shigemitsu; Takaku, Yuichi; Igarashi, Yasuhito; Yamamoto, Masayoshi

    1991-01-01

    Some long-lived radionuclides, such as 99 Tc, 226 Ra, 232 Th, 237 Np, 238 U, 239 Pu and 240 Pu were measured using high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). By using HR-ICP-MS with an ultrasonic nebulizer, the detection limits of these nuclides were 0.002-0.2 pg ml -2 and the sensitivities were 10 times better than those obtained using HR-ICP-MS without the ultrasonic nebulizer. More accurate isotopic data were also obtained using HR-ICP-MS than with quadrupole ICP-MS at lower concentrations of the analyte because of the improvement in counting statistics that can be obtained with HR-ICP-MS due to the greater efficiency of ion transmission, A comparison of the measurement of the 240 Pu to 239 Pu ratio is shown. (Author)

  13. Classification of Antarctic algae by applying Kohonen neural network with 14 elements determined by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Balbinot, L. [Departamento de Quimica Analitica-Instituto de Quimica-Unicamp, PO Box 6154, CEP: 13083-971, Campinas, SP (Brazil); Smichowski, P. [Comision Nacional de Energia Atomica, Unidad de Actividad Quimica, Centro Atomico Constituyentes, Av. Gral Paz 1499, B1650KNA, San Martin, Provincia de Buenos Aires (Argentina); Farias, S. [Comision Nacional de Energia Atomica, Unidad de Actividad Quimica, Centro Atomico Constituyentes, Av. Gral Paz 1499, B1650KNA, San Martin, Provincia de Buenos Aires (Argentina); Arruda, M.A.Z. [Departamento de Quimica Analitica-Instituto de Quimica-Unicamp, PO Box 6154, CEP