WorldWideScience

Sample records for counters radiation

  1. In-vivo radiation counter

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    This patent specification describes a radiation counter utilizing at least one detector for sensing radiation from a living body. The radiation counter also includes an aperture for forming a corridor between the body and the detector. A shield outside the corridor prevents passage of background radiation through the corridor and gaining access to the detector. The counter also includes a device for isolating a selected portion of the body from the corridor such that radiation counting is restricted to a region of the body through a separate detector. The corridor formation permits a user to stand in an upright position while the detector and detectors are able to separately monitor different sections of the body. The radiation counter overcomes the problem of obtaining accurate and quick measurements or radiation doses sustained by a large group of persons. (author)

  2. Portable microcomputer controlled radiation counter

    International Nuclear Information System (INIS)

    Mason, E.W.; Weber, J.M.

    1984-01-01

    A portable microcomputer controlled counter for use as a radiation counter is described. The counter uses digital processing of input pulses from a radiation detector. The number of counts received by the microcomputer per unit time is used to calculate a value for display using a calibration factor obtained during physical calibration of the instrument with a radiation source or with a pulse generator. The keyboard is used to enter calibration points. The number of calibration points which may be entered depends on the degree of accuracy desired by the user. The high voltage generator which drives the detector is triggered by pulses from the microcomputer in relation to the count rate. After processing the count, the resulting count rate or dose rate is displayed on the liquid crystal display. The counter is autoranging in which the decimal point is shifted as necessary by the microcomputer. The units displayed are determined by the user by means of a multiposition switch. Low battery and an overrange condition are displayed. An interface is provided via a connector to allow parallel transmission of data to peripheral devices. Low battery power consumption is featured. The counter is capable of providing more accurate readings than currently available counters

  3. Scintillation counter based radiation dosimeter

    International Nuclear Information System (INIS)

    Shin, Jeong Hyun

    2009-02-01

    The average human exposure per year is about 240mrem which is come from Radon and human body and terrestrial and cosmic radiation and man-made source. Specially radiation exposure through air from environmental radiation sources is 80mrem/yr(= 0.01mR/hr) which come from Terrestrial and cosmic radiation. Radiation dose is defined as energy deposit/mass. There are two major methods to detect radiation. First method is the energy integration using Air equivalent material like GM counter wall material. Second method is the spectrum to dose conversion method using NaI(Tl), HPGe. These two methods are using generally to detect radiation. But these methods are expensive. So we need new radiation detection method. The research purpose is the development of economical environmental radiation dosimeter. This system consists of Plastic/Inorganic scintillator and Si photo-diode based detector and counting based circuitry. So count rate(cps) can be convert to air exposure rate(R/hr). There are three major advantages in this system. First advantages is no high voltage power supply like GM counter. Second advantage is simple electronics. Simple electronics system can be achieved by Air-equivalent scintillation detector with Al filter for the same detection efficiency vs E curve. From former two advantages, we can know the most important advantages of the this system. Third advantage is economical system. The price of typical GM counter is about $1000. But the price of our system is below $100 because of plastic scintillator and simple electronics. The role of scintillation material is emitting scintillation which is the flash of light produced in certain materials when they absorb ionizing radiation. Plastic scintillator is organic scintillator which is kind of hydrocarbons. The special point are cheap price, large size production(∼ton), moderate light output, fast light emission(ns). And the role of Al filter is equalizing counting efficiency of air and scintillator for

  4. Proportional counter system for radiation measurement

    Energy Technology Data Exchange (ETDEWEB)

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  5. Counter of radiation in body parts

    International Nuclear Information System (INIS)

    Pollard, D.E.

    1983-01-01

    A new radiation counter for the determination of radiocontaminated body parts has been designed. Composed of several movable detectors, shielded from background radiation and focused on different parts of the human body by narrow apertures in the lead enclosure, the invention provides a quick tool for quantitative and qualitative part-by-part analysis of the body with respect to radiocontamination. The counter can be handled easily by the tested person himself and consequently, it is suitable for mass controls etc. (G.J.P.)

  6. Development of new portable radiation counters for promotion of better understanding of radiation by the public

    International Nuclear Information System (INIS)

    Tanabe, Hiroshi

    1995-01-01

    This study aims to promote the correct understanding of radiation to the public. All the questions asked by participants at forums held in Aomori, where commercial nuclear fuel cycle facilities are planned, were studied. More than half of these questions were concerned about radiation hazards. Measurements, using radiation counters at the meeting, provided the most effective means of explanation about radiation hazards to the public. For this purpose, portable β- and α-ray counters, being able to detect small amounts of radioactive substances around us, were developed. Each new counter is easily handled, is light-weight (about 10-20% that of domestic survey meters) and inexpensive (about 20-25% the price). The methods used to explain radiation with both counters have been also studied. This explanation has provided the public with a better understanding of the nature and hazards of radiation on human health than the former methods using textbooks. (author)

  7. The background of external γ radiation in the proportional counters in SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The influence of external γ radiation on the process of 71 Ge-decay counting in proportional counters in SAGE experiment of solar neutrino flux measurement is examined. One determines the systematic error of SAGE result, connected with radon decays inside the air volume surrounding the counters, and the background counting rate of proportional counters from γ radiation of passive and active shield [ru

  8. Background of external γ radiation in the proportional counters of the SAGE experiment

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.

    2003-01-01

    The effect of external γ radiation on the process of counting 71 Ge decays in the proportional counters of the SAGE experiment measuring the solar-neutrino flux is considered. The systematic uncertainty in the SAGE result due to radon decays inside the air volume surrounding the counters is estimated. The background counting rate in the proportional counters that is caused by γ radiation from the enclosing shield is also determined

  9. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  10. Construction of silica aerogel radiator system for Belle II RICH Counter

    Science.gov (United States)

    Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    We have developed a RICH counter as a new forward particle identification device for the Belle II experiment. As a Cherenkov radiator in this counter, a dual aerogel layer combination consisting of two refractive indicies, n=1.045 and 1.055, is employed. Mass production of these aerogel tiles has been done during 2013-2014 with new method improved by Chiba group. Optical qualities for them have been examined. The refractive indices of the obtained tiles were found to be in good agreement with our expectations, and the transparencies were high enough to be used for the RICH radiator.

  11. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    DEFF Research Database (Denmark)

    Borg, J.; Christensen, P.

    1995-01-01

    of depth-dose profiles from different beta radiation fields with E(max) values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high...... sensitivity. GM responses were measured from exposures in different beta radiation fields using different filters in front of the GM detector and the paper discusses the possibility of using the results from GM measurements with two different filters in an unknown beta radiation field to obtain a value...

  12. Needle counter

    International Nuclear Information System (INIS)

    Fujita, Yuzo

    1977-01-01

    Needle counter had been devised by Geiger about 60 years ago before the present GM counter appeared. It is suitable for the detection of weak radiation because it is limited in effective volume, if the background due to mainly cosmic ray is proportional to the effective volume of the counter. Recently the very low β detector having a needle counter as the main detector has been developed. It showed highly excellent performance in the measurements of small area samples, about ten times sensitive as compared with other detectors. The counter is installed in the very low radiation measuring well at Nokogiriyama, Chiba Prefecture, using a NaI scintillator as its guard counter. D. H. Wilkinson first treated a gas amplification counter theoretically and quantitatively. The authors have obtained good results in the comparison with the experiments of the counter using a generalized form of Wilkinson theory. The findings obtained through this study seem to be applicable to the electrode arrangement which is important for the counter design. It was found that the excellent rise time of induced pulses in a gas amplification counter was achieved in larger amplification factor and smaller convolution effect. In the detection of charged particles with small obstructing capability such as γ ray, faster rise time and higher pulses can be obtained with needle counters than wire counters. (Wakatsuki, Y.)

  13. Measurement of environmental radiation using medical scintillation detector in well counter system

    Energy Technology Data Exchange (ETDEWEB)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee [Dept. of Radiological Technology, Shingu College, Sungnam (Korea, Republic of)

    2015-12-15

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  14. Measurement of environmental radiation using medical scintillation detector in well counter system

    International Nuclear Information System (INIS)

    Lyu, Kwang Yeul; Park, Yeon Joon; Kim, Min Jeong; Ham, Eun Hye; Yoon, Ji Yeol; Kim, Hyun in; Min, Jung Hwan; Park, Hoon Hee

    2015-01-01

    After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with ‘Captus-3000 thyroid uptake measurement systems’ in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system’s sensitivity. Then we compared the results of each material’s cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like ‘High purity germanium radiation detector’. Moreover, We didn’t have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material’s spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material’s cpm with BKG, we’ve compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A

  15. Determination of dose rates in beta radiation fields using extrapolation chamber and GM counter

    International Nuclear Information System (INIS)

    Borg, J.; Christensen, P.

    1995-01-01

    The extrapolation chamber measurement method is the basic method for the determination of dose rates in beta radiation fields and the method has been used for the establishment of beta calibration fields. The paper describes important details of the method and presents results from the measurements of depth-dose profiles from different beta radiation fields with E max values down to 156 keV. Results are also presented from studies of GM counters for use as survey instruments for monitoring beta dose rates at the workplace. Advantages of GM counters are a simple measurement technique and high sensitivity. GM responses were measured from exposures in different beta radiation fields using different filters in front of the GM detector and the paper discusses the possibility of using the results from GM measurements with two different filters in an unknown beta radiation field to obtain a value of the dose rate. (Author)

  16. Development of the 'Beta-Boy' radiation counter for public acceptance activities

    International Nuclear Information System (INIS)

    Tanabe, Hiroshi; Kitada, Hiroshi

    1993-01-01

    Japan Nuclear Fuel Ltd., which was established on July 1st, 1992 largely financed by Japan's electric power companies is presently developing four projects in the village of Rokkasho, Aomori Prefecture, roughly 700 km north of Tokyo: a uranium enrichment plant, which began operation in March, 1992; a reprocessing plant to begin construction in March, 1993; a high level radioactive waste storage facility for waste returned from overseas reprocessing, construction of which began in May, 1992; and a low level radioactive waste disposal center for waste generated in nuclear power plants, which began operation in December, 1992. Approval for the location of these facilities was obtained from the authorities in Aomori Prefecture and Rokkasho Village in 1985. However, following the Chernobyl accident in 1986, the nuclear fuel cycle project in Rokkasho as well as other nuclear facilities throughout the country were faced with very active opposition from the antinuclear movement. Through our efforts to obtain public acceptance by arranging site tours, lectures, public debates and so on, we realized that many of the people of Aomori Prefecture had doubts about the nuclear fuel cycle, and that more than 80% of those people held concerns about radiation. We also found that through the demonstration of measuring atmospheric radiation levels using a large conventional portable GM survey meter of the type used in nuclear facilities, we were able to obtain considerable understanding of the nature of radiation at our lectures. Realizing therefore the need to increase this effect, we decided to develop a simple radiation counter, which all the participants at our lectures could operate themselves to measure radiation. I will now explain the characteristics of 'Beta-Boy', new radiation counter, and the method to explain radiation by using 'Beta-Boy' in our public acceptance activities

  17. Using a whole body counter to attract a younger generation to radiation and radiation protection topics

    International Nuclear Information System (INIS)

    Breustedt, B.; Mohr, U.; Bohnstedt, A.; Knebel, J.U.

    2010-01-01

    Currently there is a lack of young academics in the nuclear field especially in the field of radiation protection RP. One of the reasons is the very small number of students in the so called STEM subjects (science, technology, engineering and mathematics) which distribute among the different topics in these fields. One important task to overcome the foreseeable shortage of RP professionals is to attract pupils to this field. In routine monitoring the whole body counter of the Institute of Radiation Research (ISF) is used to identify and quantify radioactive materials that are incorporated in the human body using the technique of gamma spectroscopy. The in-vivo monitoring lab participates in activities for pupils at school level, e.g. Kinderuniversitaet, practical studies of secondary level pupils and 'Girls day'. Pupils that come to the lab are ages 14 to 18. The whole body counter is an optimal tool for these children to experience (natural) radioactivity and radiation protection issues. First pupils get a short introduction on radioactivity and gamma spectroscopy at a level adjusted to their current knowledge. After this they are measuring themselves in the whole body counter. A routine measurement of 300 s is able to show the natural occurring K-40 in their bodies. After their own measurements they do calibration measurements using a bottle phantom with a set up adjusted to their own body weights. The bottle phantom is filled with a potassium chloride (KCl) solution and contains no other radioactivity than the natural K-40 content of the KCl. Thus no further radiation protection measures need to be taken for using this phantom. A simple Excel-Sheet is then used to estimate their own K-40 activity by comparing the spectra of their measurement to the ones of the calibration measurements. This 'hands on' experience and the connection of radiation and their own bodies often is a 'eureka' effect and opens discussion on preconceptions of radiation and the need of RP

  18. Fire and earthquake counter measures in radiation handling facilities

    International Nuclear Information System (INIS)

    1985-01-01

    'Fire countermeasures in radiation handling facilities' published in 1961 is still widely utilized as a valuable guideline for those handling radiation through the revision in 1972. However, science and technology rapidly advanced, and the relevant laws were revised after the publication, and many points which do not conform to the present state have become to be found. Therefore, it was decided to rewrite this book, and the new book has been completed. The title was changed to 'Fire and earthquake countermeasures in radiation handling facilities', and the countermeasures to earthquakes were added. Moreover, consideration was given so that the book is sufficiently useful also for those concerned with fire fighting, not only for those handling radiation. In this book, the way of thinking about the countermeasures against fires and earthquakes, the countermeasures in normal state and when a fire or an earthquake occurred, the countermeasures when the warning declaration has been announced, and the data on fires, earthquakes, the risk of radioisotopes, fire fighting equipment, the earthquake counter measures for equipment, protectors and radiation measuring instruments, first aid, the example of emergency system in radiation handling facilities, the activities of fire fighters, the example of accidents and so on are described. (Kako, I.)

  19. Counter-Radiation Balm and its Medical Properties at Radiation Injuries and Functional Disorders in Gastrointestinal Tract

    International Nuclear Information System (INIS)

    Melkadze, R.; Shalamberidze, M.

    2006-01-01

    It has been shown that the Counter-Radiation Balm (CRB) is fairly effective in normalization of secretory phenomena and eubiotic state of the digestive tract in conditions of their functional disorders induced by various causes. The CRB has normalizing effect on an intestional flora during experimental dysbacterioses, induced with irradiation and starvation. This holds true in both bone marrow- and mixed patterns of acute radiation disease (ARD). The CRB somewhat decreases a toxic constituent of ARD, increases colonization resistance of the intestine to external microbial invasions and precludes extension of intestinal area for conditionally-pathogene flora. (author)

  20. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  1. Calibration of proportional counters in microdosimetry

    International Nuclear Information System (INIS)

    Varma, M.N.

    1982-01-01

    Many microdosimetric spectra for low LET as well as high LET radiations are measured using commercially available (similar to EG and G) Rossi proportional counters. This paper discusses the corrections to be applied to data when calibration of the counter is made using one type of radiation, and then the counter is used in a different radiation field. The principal correction factor is due to differences in W-value of the radiation used for calibration and the radiation for which microdosimetric measurements are made. Both propane and methane base tissue-equivalent (TE) gases are used in these counters. When calibrating the detectors, it is important to use the correct stopping power value for that gas. Deviations in y-bar/sub F/ and y-bar/sub D/ are calculated for 60 Co using different extrapolation procedures from 0.15 keV/μm to zero event size. These deviations can be as large as 30%. Advantages of reporting microdosimetric parameters such as y-bar/sub F/ and y-bar/sub D/ above a certain minimum cut-off are discussed

  2. Radiation level measured by a portable Geiger-Mueller counter at the altitude of commercial air routes

    International Nuclear Information System (INIS)

    Araki, Takashi

    1995-01-01

    The background intensities of naturally occurring radiation were measured aboard scheduled commercial airplanes using a newly developed Geiger-Mueller counter with a pocket computer. The preliminary results show that the radiation at the cruising altitude of a commercial airplane on a transcontinental flight is 40 times higher than the ground-level. (author)

  3. Fiber-Optic Monitoring System of Particle Counters

    Directory of Open Access Journals (Sweden)

    A. A. Titov

    2016-01-01

    Full Text Available The article considers development of a fiber-optic system to monitor the counters of particles. Presently, optical counters of particles, which are often arranged at considerable distance from each other, are used to study the saltation phenomenon. For monitoring the counters, can be used electric communication lines.However, it complicates and raises the price of system Therefore, we offered a fiber-optic system and the counter of particles, free from these shortcomings. The difference between the offered counter of particles and the known one is that the input of radiation to the counter and the output of radiation scattering on particles are made by the optical fibers, and direct radiation is entered the optical fiber rather than is delayed by a light trap and can be used for lighting the other counters thereby allowing to use their connection in series.The work involved a choice of the quartz multimode optical fiber for communication, defining the optical fiber and lenses parameters of the counter of particles, and a selection of the radiation source and the photo-detector.Using the theory of light diffraction on a particle, a measuring range of the particle sizes has been determined. The system speed has been estimated, and it has been shown that a range of communication can reach 200km.It should be noted that modulation noise of counters of particles connected in series have the impact on the useful signal. To assess the extent of this influence we have developed a calculation procedure to illustrate that with ten counters connected in series this influence on the signal-to-noise ratio will be insignificant.Thus, it has been shown that the offered fiber-optic system can be used for monitoring the counters of particles across the desertified territories. 

  4. An introduction to automatic radioactive sample counters

    International Nuclear Information System (INIS)

    1980-01-01

    The subject is covered in chapters, entitled; the detection of radiation in sample counters; nucleonic equipment; liquid scintillation counting; basic features of automatic sample counters; statistics of counting; data analysis; purchase, installation, calibration and maintenance of automatic sample counters. (U.K.)

  5. Expanded and combined uncertainty in measurements by GM counters

    International Nuclear Information System (INIS)

    Stankovic, K.; Arandjic, D.; Lazarevic, Dj.; Osmokrovic, P.

    2007-01-01

    This paper deals with possible ways of obtaining expanded and combined uncertainty in measurements for four types of GM counters with a same counter's tube, in cases when the contributors of these uncertainties are cosmic background radiation and induced overvoltage phenomena. Nowadays, as a consequence of electromagnetic radiation, the latter phenomenon is especially marked in urban environments. Based on experimental results obtained, it has been established that the uncertainties of an influenced random variable 'number of pulses from background radiation' and 'number of pulses induced by overvoltage' depend on the technological solution of the counter's reading system and contribute in different ways to the expanded and combined uncertainty in measurements of the applied types of GM counters. (author)

  6. Comparison of the measured radiation dose-rate by the ionization chamber and G (Geiger-Mueller) counter after radioactive lodine therapy in differentiated thyroid cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kwang Hun [Dept. of Nuclear Medicine, Kyungbuk National University Hospital, Daegu (Korea, Republic of); Kim, Kgu Hwan [Dept. of Radiological Technology, Daegu Health College, Daegu (Korea, Republic of)

    2016-12-15

    Radioactive iodine(131I) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

  7. Whole-body counter

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, G A; Kosterev, V V

    1975-01-24

    A counter for detecting radiation of a man (CRM) is described, which consists of two measuring converters and a recording device. In order to obtain data on spatial distribution of a gamma-radiating nuclide studied, a fixed collimator and a mobile coder made of separate slit elements are placed between the measuring converters and an object investigated.

  8. Multi-element proportional counter for radiation protection measurements

    International Nuclear Information System (INIS)

    Kliauga, P.; Rossi, H.H.; Johnson, G.

    1988-01-01

    This article discusses design modifications of a multi-element proportional counter. The original counter exhibited poor resolution, as measured by the width of the event-size spectrum for low-energy photons. It was also suspected that the field inside each volume was not sufficiently symmetric. Results of the modifications showed that a dramatic improvement in resolution could be obtained in the chamber with tissue-equivalent septa if their potentials were adjusted to obtain optimal resolution. The full width at half maximum then approached, although it did not equal, that of a standard spherical counter

  9. Influence of tube volume on measurement uncertainty of GM counters

    Directory of Open Access Journals (Sweden)

    Stanković Koviljka Đ.

    2010-01-01

    Full Text Available GM counters are often used in radiation detection since they generate a strong signal which can be easily detected. The working principal of a GM counter is based on the interaction of ionizing radiation with the atoms and molecules of the gas present in the counter's tube. Free electrons created as a result of this interaction become initial electrons, i. e. start an avalanche process which is detected as a pulse of current. This current pulse is independent of the energy imparted on the gas, that being the main difference between a GM counter and the majority of other radiation detectors. In literature, the dependence on the incidence of radiation energy, tube's orientation and characteristics of the reading system are quoted as the main sources of measurement uncertainty of GM counters. The aim of this paper is to determine the dependence of measurement uncertainty of a GM counter on the volume of its counter's tube. The dependence of the pulse current on the size of the counter's tube has, therefore, been considered here, both in radial and parallel geometry. The initiation and expansion of the current pulse have been examined by means of elementary processes of electrical discharge such as the Markov processes, while the changes in the counter's tube volume were put to test by the space - time enlargement law. The random variable known as the 'current pulse in the counter's tube' (i. e. electrical breakdown of the electrode configuration has also been taken into account and an appropriate theoretical distribution statistically determined. Thus obtained theoretical results were then compared to corresponding experimental results established in controlled laboratory conditions.

  10. Radiation protection instruments based on tissue equivalent proportional counters: Part II of an international intercomparison

    International Nuclear Information System (INIS)

    Alberts, W.G.; Dietz, E.; Guldbakke, S.; Kluge, H.; Schumacher, H.

    1988-04-01

    This report describes the irradiation conditions and procedures of Part II of an international intercomparison of tissue-equivalent proportional counters used for radiation protection measurements. The irradiations took place in monoenergetic reference neutron fields produced by the research reactor and accelerator facilities of the PTB Braunschweig in the range from thermal neutrons to 14.8 MeV. In addition measurements were performed in 60 Co and D 2 O-moderated 252 Cf radiation fields. Prototype instruments from 7 European groups were investigated. The results of the measurements are summarized and compared with the reference data of the irradiations. (orig.) [de

  11. Tests of BF3 counters with getter

    International Nuclear Information System (INIS)

    Comte, R.; Dauphin, G.

    1968-01-01

    BF 3 counters with addition of a getter have been developed to improve operation characteristics of these detectors in presence of strong gamma flows. The getter is made of an active coal deposit on the cathode. As noticed by other studies, the degradation of these counters is related to the exposure to strong neutron flows and to gamma radiations. The authors report tests performed on these counters with a brief presentation of the counters, and a presentation of the test installation. A threshold curve and an amplitude spectrum are obtained, and counting is performed for a fixed threshold before and after the exposure of detectors to variable doses of γ radiation. The results after a first 2 hour long irradiation, a 230 hour long second irradiation, and a third irradiation under high voltage (2100 V) are discussed. Thermal tests are then performed and commented

  12. Beam test of Cherenkov counter prototype for ZDF setup

    International Nuclear Information System (INIS)

    Kacharava, A.K.; Macharashvili, G.G.; Nioradze, M.S.; Komarov, V.I.; Sopov, V.S.; Chernyshev, V.P.

    1995-01-01

    We describe a Cherenkov counter of total internal reflection for particle separation in the momentum range where all types of particles radiate Cherenkov light. The Cherenkov counter prototype with the lucite radiator was tested on the secondary beam of the ITEP (Moscow) accelerator. Dependence of the photomultiplier pulse height on the particle entrance angle was clearly observed. 4 refs., 4 figs

  13. Constant sensitivity circuit for solid state nuclear radiation counters

    International Nuclear Information System (INIS)

    Kronenberg, S.; Erkkila, B.

    1985-01-01

    The utilization of solid state counters in tactical radiological instruments for measuring intensities and doses of fallout gamma rays offers advantages over Geiger-Mueller (GM) counters such as a much wider dynamic range and low operating voltages. Their very small size is suitable for use in miniaturized equipment. However, these devices have a serious problem if used in a mixed, fast neutron/gamma environment such as is encountered e.g. in a battlefield where tactical nuclear weapons are used and neutrons, prompt, initial gammas and fallout gammas are killing factors of comparable importance. Exposure to fast neutrons reduces seriously their sensitivity. This makes the solid state counters at this time unacceptable for use in Army tactical surveillance equipment and in other applications where according to requirements the performance must not be impaired by exposure to fast neutrons. It seems to be possible to reduce to some extent this neutron generated damage by improving the crystal counters

  14. Suppression and utilization of spurious pulse occurence in organic GM-counters

    International Nuclear Information System (INIS)

    Narita, Y.; Igarashi, R.; Akagami, H.; Ozawa, Y.

    1979-01-01

    The authors have made a study of suppression and utilization of spurious pulse occurrence in organic GM-counters. Almost all spurious pulses in the organic GM-counter are the delayed pulses which occur being dependent upon the radiation intensity. The occurrence rate of the delayed pulses against the radiation intensity is affected by the intensity of the electric field in the vicinity of the cathode of the GM-counter. The occurrence of the delayed pulses can be suppressed when the electric field in the vicinity of the cathode is kept at high value. On the contrary, the occurrence of the delayed pulses can be utilized for the dosimetry of the pulsed radiation by means of increasing the space of the weak electric field in the GM-counter. (Auth.)

  15. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  16. Absolute determination of radiation bursts and of proportional counters space charge effect through the influence method

    International Nuclear Information System (INIS)

    Rios, I.J.; Mayer, R.E.

    2016-01-01

    When proportional counters are employed in charge integration mode to determine the magnitude of a radiation pulse, so intense that individual detection events take place in a time too short to produce individual output pulses, mostly in pulsed neutron sources, the strong build-up of positive space charge reduces the electric multiplication factor of the proportional detector. Under such conditions the ensuing measurement underestimates the amount of radiation that interacted with the detector. If the geometric characteristics, the filling gas pressure and the voltage applied to that detector are known, it becomes possible to apply an analytical correction method to the measurement. In this article we present a method that allows to determine the absolute value of the detected radiation burst without the need to know the characteristics of the employed detectors. It is necessary to employ more than one detector, taking advantage of the Influence Method. The “Influence Method” is conceived for the absolute determination of a nuclear particle flux in the absence of known detector efficiency and without the need to register coincidences of any kind. This method exploits the influence of the presence of one detector in the count rate of another detector, when they are placed one behind the other and define statistical estimators for the absolute number of incident particles and for the efficiency (Rios and Mayer, 2015 [1,2]). Its practical implementation in the measurement of a moderated neutron flux arising from an isotopic neutron source was exemplified in (Rios and Mayer, 2016 [3]) and the extension for multiple detectors in (Rios and Mayer 2016 [4]). - Highlights: • Absolute determination of radiation burst. • Proportional counters space charge effect. • Radiation measurements on pulsed devices.

  17. Development and Characterization of Tissue Equivalent Proportional Counter for Radiation Monitoring in International Space Station

    Directory of Open Access Journals (Sweden)

    Uk-Won Nam

    2013-06-01

    Full Text Available Tissue equivalent proportional counter (TEPC can measure the Linear Energy Transfer (LET spectrum and calculate the equivalent dose for the complicated radiation field in space. In this paper, we developed and characterized a TEPC for radiation monitoring in International Space Station (ISS. The prototype TEPC which can simulate a 2 μm of the site diameter for micro-dosimetry has been tested with a standard alpha source (241Am, 5.5 MeV. Also, the calibration of the TEPC was performed by the 252Cf neutron standard source in Korea Research Institute of Standards and Science (KRISS. The determined calibration factor was kf = 3.59×10-7 mSv/R.

  18. Output pulse height distribution of the GM counters

    International Nuclear Information System (INIS)

    Zhang Songshou; Xiong Jianping

    1995-01-01

    The GM counters are the radiation detectors most in use. It has special advantages compared with other detectors. This paper introduces the output pulse height distribution of the GM counters, gives the measuring instruments and methods. The measuring results, some discussions, and useful conclusion are given as well

  19. Fundamentals of gas counters

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1994-01-01

    The operation of gas counters used for detecting radiation is explained in terms of the four fundamental physical processes which govern their operation. These are 1) conversion of neutral radiation into charged particles, 2) ionization of the host gas by a fast charge particle 3) transport of the gas ions to the electrodes and 4) amplification of the electrons in a region of enhanced electric field. Practical implications of these are illustrated. (UK)

  20. Calibration and Monte Carlo modelling of neutron long counters

    CERN Document Server

    Tagziria, H

    2000-01-01

    The Monte Carlo technique has become a very powerful tool in radiation transport as full advantage is taken of enhanced cross-section data, more powerful computers and statistical techniques, together with better characterisation of neutron and photon source spectra. At the National Physical Laboratory, calculations using the Monte Carlo radiation transport code MCNP-4B have been combined with accurate measurements to characterise two long counters routinely used to standardise monoenergetic neutron fields. New and more accurate response function curves have been produced for both long counters. A novel approach using Monte Carlo methods has been developed, validated and used to model the response function of the counters and determine more accurately their effective centres, which have always been difficult to establish experimentally. Calculations and measurements agree well, especially for the De Pangher long counter for which details of the design and constructional material are well known. The sensitivit...

  1. Radiation measurement

    International Nuclear Information System (INIS)

    Go, Sung Jin; Kim, Seung Guk; No, Gyeong Seok; Park, Myeong Hwan; Ann, Bong Seon

    1998-03-01

    This book explains technical terms about radiation measurement, which are radiation, radiation quantity and unit such as prefix of international unit, unit for defence purposes of radiation, coefficient of radiation and interaction, kinds and principles of radiation detector, ionization chamber, G-M counter, G-M tube, proportional counter, scintillation detector, semiconductor radiation detector, thermoluminescence dosimeter, PLD, others detector, radiation monitor, neutron detector, calibration of radiation detector, statistics of counting value, activation analysis and electronics circuit of radiation detector.

  2. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A critical evaluaton is presented of the actual state of investigations and explanations of the resolution and pulse height changes resulted in proportional counters from radiation intensity variations. (author)

  3. Townsend coefficients of gases in avalanche counters

    International Nuclear Information System (INIS)

    Brunner, G.

    1978-01-01

    Though much work has been done by many authors in the last few years in the development and application of avalanche counters for ion radiation, it is based upon values of the Townsend coefficients as the essential gas parameter, which were determined many years ago for much lower reduced field strengths F/p than prevail in such counters. Therefore absolute determinations of α in vapours of methyl alcohol, cyclohexane, acetone, and n-heptene were performed under original conditions of avalanche counters. The values obtained do not differ by more than 30%-50% from the former values indeed, extrapolated over F/p for the first three mentioned substances, but the amounts of A and B in the usual representation α/p=A exp(-B(F/p)) are much greater for the stronger reduced fields. This is of importance for such counter properties as the dependence of pulse heights on pressure, voltage, electrode distance etc., which are governed by other combinations of A and B than α/p itself. A comparison of results for different ionic radiations shows a marked influence of the primary ionization density along the particle tracks which is hard to explain. (Auth.)

  4. Silica aerogel Cherenkov counter for the KEK B-factory experiment

    CERN Document Server

    Sumiyoshi, T; Enomoto, R; Iijima, T; Suda, R; Leonidopoulos, C; Marlow, D R; Prebys, E; Kawabata, R; Kawai, H; Ooba, T; Nanao, M; Suzuki, K; Ogawa, S; Murakami, A; Khan, M H R

    1999-01-01

    Low-refractive-index silica aerogel is a convenient radiator for threshold-type Cherenkov counters, which are used for particle identification in high-energy physics experiments. For the BELLE detector at the KEK B-Factory we have produced about 2 m sup 3 of hydrophobic silica aerogels of n=1.01-1.03 using a new production method. The particle identification capability of the aerogel Cherenkov counters was tested and 3 sigma pion/proton separation has been achieved at 3.5 GeV/c. Radiation hardness of the aerogels was confirmed up to 9.8 Mrad. The Aerogel Cherenkov counter system (ACC) was successfully installed in the BELLE just before this conference.

  5. An unshielded whole body radioactivity counter for monitoring persons after a radiation accident

    International Nuclear Information System (INIS)

    Katoch, D.S.; Somasundaram, S.

    1979-01-01

    An unshielded chair in which the subject sits, holding a 7.6 cm x 7.6 cm NaI (Tl) detector in his lap, was evaluated for monitoring of persons suspected of internal radioactive contamination following a radiation accident. The reduction in different energy bands of the background gamma-ray spectrum due to self-shielding of the subject was studied for two postures, designated ''upright'' and ''folding'' and the data were analysed in a CDC 3600 computer to obtain the best-fit regression equation relating the reduction factor with body weight and height. The response of the counter was evaluated using an in vitro method and the ranges of under/over-estimation of body burden resulting from assumption of partial/uniform distribution of activity were determined. Counting sensitivities were derived for 13 radioisotopes having gamma-ray energies in the range 145 keV-1.46 MeV. The results are presented and discussed. The study shows that this simple system may be used not only in radiation emergencies but also for operational monitoring of radiation workers for a number of radioisotopes of low and medium radiotoxicity. (auth.)

  6. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported

  7. Irradiated fuel bundle counter

    International Nuclear Information System (INIS)

    Campbell, J.W.; Todd, J.L.

    1975-01-01

    The design of a prototype safeguards instrument for determining the number of irradiated fuel assemblies leaving an on-power refueled reactor is described. Design details include radiation detection techniques, data processing and display, unattended operation capabilities and data security methods. Development and operating history of the bundle counter is reported. (U.S.)

  8. Position-sensitive proportional counter

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit uses a conventional (low-resistance, metal-wire anode) counter for spatial resolution of an ionizing event along the anode, which functions as an RC line. A pair of preamplifiers at the anode ends act as stabilized active-capacitance loads, each comprising a series-feedback, low-noise amplifier and a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction of handling of the anodes, and stabilizes the anode resistivity at high count rates (>10 6 counts/sec). (author)

  9. The Micro Trench Gas Counter

    International Nuclear Information System (INIS)

    Schmitz, J.

    1991-07-01

    A novel design is presented for a gas avalanche chamber with micro-strip gas readout. While existing gaseous microstrip detectors (Micro-strip Gas Counters, Knife edge chambers) have a minimum anode pitch of the order of 100 μm, the pitch of the discussed Micro Trench Gas Counter goes down to 30-50 μm. This leads to a better position resolution and two track separation, and a higher radiation resistivity. Its efficiency and signal speed are expected to be the same as the Microstrip Gas Counter. The energy resolution of the device is expected to be equal to or better than 10 percent for the 55 Fe peak. Since the anode strip dimensions are larger than those in a MSGC, the device may be not as sensitive to discharges and mechanical damage. In this report production of the device is briefly described, and predictions on its operation are made based on electric field calculations and experience with the Microstrip Gas Counter. The authors restrict themselves to the application in High Energy Physics. (author). 10 refs.; 9 figs

  10. Scintillation counter, segmented shield

    International Nuclear Information System (INIS)

    Olson, R.E.; Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  11. Geiger-Muller (GM) counters. Associated circuits and counting techniques; Les compteurs de Geiger-Muller (GM). Les circuits associes et techniques de comptage

    Energy Technology Data Exchange (ETDEWEB)

    Benoit, A.; Picard, E. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay (France)

    1954-07-01

    This article presents the Geiger-Muller counters which present the great benefit of being simple and steady in comparison with other known sensors. The authors propose an overview of problems related to the use of Geiger-Muller counters (GM counters). They first describe their operation (discharge initiation, discharge propagation, collection of positive ions and current in the counter). They discuss their limitations which are related to the migration delay of primary electrons and positive ions. They describe the operation circuit for counters with organic vapour, and for counters associated with counters using halogens. They address the main properties of GM counters, and the different factors to be taken into account when using them to count radioactive sources. The main types of GM counters are then described (they are used to measure different types of radiation). Measurement techniques are discussed for beta radiation (relationship between the number of disintegrations and the noticed counting rate, case of backscattering, absorption and diffusion in the counter window and in the air, influence of absorption and backscattering in the source), for alpha radiation, and for gamma radiation.

  12. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Science.gov (United States)

    Sunil, C.; Tyagi, Mohit; Biju, K.; Shanbhag, A. A.; Bandyopadhyay, T.

    2015-12-01

    The scarcity and the high cost of 3He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am-Be neutron source shows promise of being used as rem counter.

  13. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    Energy Technology Data Exchange (ETDEWEB)

    Sunil, C., E-mail: csunil11@gmail.com [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Tyagi, Mohit [Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India); Biju, K.; Shanbhag, A.A.; Bandyopadhyay, T. [Accelerator Radiation Safety Section, Health Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 (India)

    2015-12-11

    The scarcity and the high cost of {sup 3}He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am–Be neutron source shows promise of being used as rem counter.

  14. Radiation thickness gauge using beta particle sensitivity controlled open air corona streamer counter

    International Nuclear Information System (INIS)

    Fouad, L.; El-Hazek, S.; El-Araby, S.

    1999-01-01

    Beta particles have been used extensively in radio gauging applications when measurements of foil thicknesses are desired. Using beta particle open air corona streamer counter (point-grid-plane) as a thickness gauge is presented. This gauge consists of two similar counters with two similar Sr-90 beta sources. One counter-source combination is called standard unit, and the other counter-source combination is called measuring unit in which the required foil thickness can be measured by inserting it between the source and the counter. The signals from the counters are amplified with the same gain factor and the net difference between their responses is measured using specially designed electronic circuit. By this way any change that takes place in the operating medium (variation of parameters of open air i.e. temperature, humidity...etc) can similarly affect the two units, the errors in the measurements caused by them are cancelled, and the only response is due to the measured foil thickness. A theoretical model is suggested to explain and analyze the overall response of the gauge system and calculate the calibration thickness gauge constant. All theoretical findings are confirmed by experiments

  15. The influence of the counter-rotating terms on the superradiant emission

    International Nuclear Information System (INIS)

    Seke, J.

    1984-01-01

    Agarwal's master equation for the Dicke model is modified by including the counter-rotating terms. By solving the corresponding equations of motion for the atomic expectation values, it is shown that the counter-rotating terms play an important role in the time evolution of the population inversion and radiation rate

  16. Effect of counter electric field during the irradiation of pulsed x-ray on the after-pulses of GM counter

    International Nuclear Information System (INIS)

    Igarashi, Ryuji; Narita, Yuichi; Ozawa, Yasutomo.

    1979-01-01

    The authors once made it clear by using pulsed radiation that the number of spurious discharge generation in organic gas-quenching type GM counters depends on the intensity of incident radiation. This spurious discharge is peculiar to the organic gas-quenching type GM counters, which the authors named after-pulses. The present study has been carried out to find the experimental conditions to verify the delayed generation mechanism of such after-pulses in bipolar GM tubes and the conditions to give the maximum number of after-pulses generation. For this purpose, a large low electric field region, whose field intensity is variable, should be provided in the tubes. Since it has been generally impossible in the bipolar GM tubes, the provision of that region transiently has been tried. The effect of the intensity of electric field in GM tubes during irradiation on the generation of after-pulses has been investigated by changing radiation intensity, anode voltage, and irradiated position. Consideration of the results has revealed that the number of after-pulse generation can be increased by forming transient low electric field region in the bipolar GM counters of organic gas-quenching type. It was the new knowledge that the transient anode voltage to maximize the after-pulse generating factor was several tens of negative voltage even if the conditions were varied. It seems that this fact depends upon the voltage giving the conditions to maximize the probability of forming after-pulse factors. (Wakatsuki, Y.)

  17. TOP counter for particle identification at the Belle II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Inami, Kenji

    2014-12-01

    Ring imaging Cherenkov counter, named TOP counter, utilizing precise photon detection timing has been developed as a particle identification detector for the Belle II experiment. The real size prototype has been produced and tested with 2 GeV positrons at Spring-8 LEPS beam line. The quartz radiator production and assembling with microchannel plate photomultipliers was successfully carried out. The beam test data shows good agreement with full Monte-Carlo simulation results in the ring image and the distribution of number of detected photons and timing information. - Highlights: • TOP counter was developed as a particle identification detector for the Belle II experiment. • The real size prototype was produced and tested with 2 GeV positrons. • The quartz radiator production and assembling with MCP-PMT was successfully carried out. • The beam test data shows good agreement with full Monte-Carlo simulation results.

  18. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  19. Development of DUPIC safeguards neutron counter

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gil; Cha, Hong Ryul; Kim, Ho Dong; Hong, Jong Sook; Kang, Hee Young

    1999-08-01

    KAERI, in cooperation with LANL, developed DSNC (DUPIC Safeguards Neutron Counter) for safeguards implementing on DUPIC process which is under development by KAERI for direct use of spent PWR fuel in CANDU reactors. DSNC is a well-type neutron coincidence counter with substantial shielding to protect system from high gamma radiation of spent fuel. General development procedures in terms of design, manufacturing, fabrication, cold and hot test, performance test for DSNC authentication by KAERI-IAEA-LANL are described in this report. It is expected that the techniques related DSNC development and associated neutron detection and evaluation method could be applied for safeguards improvement. (Author). 20 refs., 16 tabs. 98 figs.

  20. PLASMA EMISSION BY COUNTER-STREAMING ELECTRON BEAMS

    Energy Technology Data Exchange (ETDEWEB)

    Ziebell, L. F.; Petruzzellis, L. T.; Gaelzer, R. [Instituto de Física, UFRGS, Porto Alegre, RS (Brazil); Yoon, P. H. [Institute for Physical Science and Technology, University of Maryland, College Park, MD (United States); Pavan, J., E-mail: luiz.ziebell@ufrgs.br, E-mail: yoonp@umd.edu, E-mail: joel.pavan@ufpel.edu.br [Instituto de Física e Matemática, UFPel, Pelotas, RS (Brazil)

    2016-02-10

    The radiation emission mechanism responsible for both type-II and type-III solar radio bursts is commonly accepted as plasma emission. Recently Ganse et al. suggested that type-II radio bursts may be enhanced when the electron foreshock geometry of a coronal mass ejection contains a double hump structure. They reasoned that the counter-streaming electron beams that exist between the double shocks may enhance the nonlinear coalescence interaction, thereby giving rise to more efficient generation of radiation. Ganse et al. employed a particle-in-cell simulation to study such a scenario. The present paper revisits the same problem with EM weak turbulence theory, and show that the fundamental (F) emission is not greatly affected by the presence of counter-streaming beams, but the harmonic (H) emission becomes somewhat more effective when the two beams are present. The present finding is thus complementary to the work by Ganse et al.

  1. Verification of surface source's characteristics using large-area 2π gas flow counter

    International Nuclear Information System (INIS)

    Abu Naser Waheed, M.M.; Mikami, S.; Kobayashi, H.; Noda, K.

    1998-09-01

    Power Reactor and Nuclear Fuel Development Corporation (PNC) has large-area 2π gas flow counter for the purpose of measuring activity of surface sources of alpha or beta ray emitter. Surface sources are used for the calibration of radiation measuring equipment for radiation control. Due to sequent use of sources, the surface of these sources are inclined to go in bad condition because of unwanted accidental incidents. For the better calibration achievement of radiation measuring instruments the rate of emission of these sources are to be checked periodically by the large-area 2π gas flow counter. In this paper described that eight U 3 O 8 surface sources were selected from many sources of PNC Tokai Works and activity of these sources was measured by the 2π gas flow counter. The results were compared with the values certified by Japan Radio Isotope Association (JRIA). It is evident from the result of comparison that the surface sources are in good condition, i.e., the sources are reliable to calibrate the radiation control instruments. (author)

  2. Real-time {sup 90}Sr Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi; Kobayashi, Atsushi; Tabata, Makoto; Ito, Hiroshi [Graduate School of Science, Chiba University, Chiba, (Japan); Han, Soorim [Graduate School of Science, Chiba University, Chiba, (Japan); National Institute of Radiological Science, Chiba, (Japan)

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray of maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower

  3. Development of a drift tissue equivalent proportional counter for radiation protection personnel dosimetry

    International Nuclear Information System (INIS)

    Bordy, J.M.

    1992-04-01

    A new multicellular geometry for proportional counter has been developed. It is made of several drift regions which are some holes drilled in the cathode in front of anodes wires. The present work is made of 3 parts: 1) A theoretical evaluation of the multicellular counter characteristics: the sensitivity increases by a factor 15 vs the Tinelli Merlin-Gerin counter; the chord length distribution study shows the possibility to use a Dirac function for the dosimetry calculations; a tissue equivalent gas mixture based on argon and propane is designed. 2) The production of a monocellular prototype made of a hole and a needle shaped anode. 3) An experimental study of the prototype electrical characteristics and a computation of the electrical field in the counter. The focalization and the electron drift into the hole, the proportional operating mode are shown. Irradiations in front of photon and neutron sources verify these results

  4. Improvements to well scintillation counters

    International Nuclear Information System (INIS)

    Farukhi, M.R.; Mataraza, G.A.; Wimer, O.D.

    1977-01-01

    This invention relates to the field of ionising radiation detection. It concerns in particular scintillation detectors of the type that is commonly used in conjunction with a photomultiplier tube and that is used for monitoring radiation, for instance in the clinical measurements of isotopes. This invention enables well scintillation counters to be made, characterised by a high efficiency in measuring the thindown rate of radio-pharmaceutical solutions and to resolve the distribution of energy emanating from the radioactive source. It particularly consists in improving the uniformity of the luminous efficiency, the quality of the resolution and the efficiency whilst improving the reception of light [fr

  5. Possibility of experiments using radiation counters for test electron stability and Pauli principle violation in atoms

    International Nuclear Information System (INIS)

    Barabash, A.S.

    1989-01-01

    Capabilities of modern radiation detectors for investigation into electron stability and possible violation of Pauli principle in atoms are discussed. For experimental searches of electron instability the following low-background devices are used: scintillation NaI-detectors, semiconducting detectors of enriched germanium, emission chamber, multisection proportional counter and low-temperature detectors. It is ascertained that using modern low-background devices applying the earlier enumerated detectors, it is possible to achieve sensitivity of the order of 10 24 -10 25 years for the electron lifetime relatively to its decay and Pauli principle violation in atoms. Experiments with sensitivity of ∼ 10 26 -10 27 can be realized in massive low-temperature detectors, developed for neutrino physics. 28 refs; 1 fig

  6. Developing GIS based decision-support tools for agricultural counter-measurements after radiation accident

    International Nuclear Information System (INIS)

    Kepka, Pavel; Prochazka, Jan; Brom, Jakub; Pecharova, Emilie

    2009-01-01

    There is a whole variety of possibilities proposed by EURANOS data sheets for agriculture, for mid-term and long-term counter-measures after contamination of crops by radiation. We have developed a set of supportive tools for decision-makers within the project 'Methods of evaluation of contaminated territory after radiation accident - the importance of structure and functioning of a land cover'. Our TM tools are based on ArcGIS platform and Python programming language. We have developed a simple model for estimating the current biomass of the polluted crops. Inputs for this model are: a shape file of land cover data, database table with customisable plant growth characteristics and shape file of polluted areas. The model provides a shape file data set of estimated amounts of biomass of selected crops per hectare for a given day. The results are helpful for better performing of the countermeasure 'Early removal of crops'. The total amount of polluted waste, logistic costs (transport of people and material; required time; other costs) could be estimated only with basic GIS tools. The number of days expected for the harvest can be also calculated and compared with the dose and half-lives of the contaminating radionuclides. This analysis could also lead to a 'Do nothing' decision, especially in case of radionuclides with short times of half-life. (author)

  7. Radiation measuring instrument

    International Nuclear Information System (INIS)

    Genrich, V.

    1985-01-01

    A highly sensitive and compactly structured radiation measuring instrument for detecting ionizing radiation, in particular for measuring dose rates and contamination. The laminar structure of the associated counter tube, using only a few, simple plastic parts and a highly elastic counter wire, makes it possible to use the simplest manufacturing techniques. The service life of the counter tube construction, which is completely and permanently sealed and filled with gas, is expected to be more than 12 years. The described counter tube can be adapted in optimal fashion to the available space in a pocket instrument if it is used in combination with a specialized high-voltage generator which is low in interference voltage and with a pulse evaluation circuit having a means of compensating for interference voltage

  8. Distributed performance counters

    Science.gov (United States)

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  9. Study of the gamma radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1949-12-01

    A Geiger counter study has been made of the ..gamma.. radiation of ionium. Eleven quanta of the L radiation of radium were observed for every hundred ..cap alpha.. disintegrations, and three ..gamma.. rays were found with energies of 68, 140, and 240 keV at a rate of 0.85, 0.33, 0.05 quanta, respectively, for 100 disintegrations. It is noted that the radiation spectrum of ionium as a whole is difficult to interpret. In the course of this work, the author calculated the efficiency of a thin-walled aluminum counter, both for the L radiation of radium and for ..gamma.. rays of 68 keV. The author also measured, for soft radiation, the ratio between the efficiency of a thin-walled aluminum counter and that of a similar counter lined with 0.11 mm of lead.

  10. ''Intelligent'' radiation measurements

    International Nuclear Information System (INIS)

    Ward, A.

    1980-01-01

    A description is given of three applications of current microprocessor technology which are characterized by the use of the microprocessor to impart a degree of intelligence to conventional radiation detection techniques. In the first application the microcomputer computes the radiation dose from the observed counting rate in a Geiger counter. In the second application the microcomputer provides the pulse height distribution and the radioisotopes used, from the spectrum of pulses from a scintillation counter. The third application is an arrangement for radiation monitor calibration. (H.K.)

  11. Geiger counters of gamma rays with a bismuth cathode

    International Nuclear Information System (INIS)

    Meunier, R.; Legrand, J.P.

    1953-01-01

    Geiger Muller counters present a lake of efficiency of some per cent, for the γ radiations. In the region 0,3 - 1 MeV, a substantial growth of their output can be obtained by a special construction of their cathode. In accordance with previous works, we constructed some counter of formed cathode by a pleated copper wire fencing covered of Bi by electrolysis. The successive modifications brought to a cylindrical conventional cathode in sheet metal of copper, that succeeds to this type of cathode, drive to an improvement of the output. (M.B.) [fr

  12. Scintillation counter: photomultiplier tube alignment

    International Nuclear Information System (INIS)

    Olson, R.E.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into the sample receiving zone. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (auth)

  13. Non-Imaging Detectors and Counters. Chapter 10

    Energy Technology Data Exchange (ETDEWEB)

    Zanzonico, P. B. [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York (United States)

    2014-12-15

    Historically, nuclear medicine has been largely an imaging based specialty, employing such diverse and increasingly sophisticated modalities as rectilinear scanning, (planar) gamma camera imaging, single photon emission computed tomography (SPECT) and positron emission tomography (PET). Non-imaging radiation detection, however, remains an essential component of nuclear medicine. This chapter reviews the operating principles, performance, applications and quality control (QC) of the various non-imaging radiation detection and measurement devices used in nuclear medicine, including survey meters, dose calibrators, well counters, intra-operative probes and organ uptake probes. Related topics, including the basics of radiation detection, statistics of nuclear counting, electronics, generic instrumentation performance parameters and nuclear medicine imaging devices, are reviewed in depth in other chapters of this book.

  14. Detectors for particle radiation. 2. rev. ed.

    International Nuclear Information System (INIS)

    Kleinknecht, K.

    1987-01-01

    This book is a description of the set-up and mode of action of detectors for charged particles and gamma radiation for students of physics, as well as for experimental physicists and engineers in research and industry: Ionization chamber, proportional counter, semiconductor counter; proportional chamber, drift chamber, bubble chamber, spark chamber, photomultiplier, laser ionization, silicion strip detector; Cherenkov counter, transition radiation detector; electron-photon-cascade counter, hadron calorimeter; magnetic spectrometer; applications in nuclear medicine, geophysics, space travel, atom physics, nuclear physics, and high-energy physics. With 149 figs., 20 tabs [de

  15. Calibration of the neutron scintillation counter threshold

    International Nuclear Information System (INIS)

    Noga, V.I.; Ranyuk, Yu.N.; Telegin, Yu.N.

    1978-01-01

    A method for calibrating the threshold of a neutron counter in the form of a 10x10x40 cm plastic scintillator is described. The method is based on the evaluation of the Compton boundary of γ-spectrum from the discrimination curve of counter loading. The results of calibration using 60 Co and 24 Na γ-sources are given. In order to eValuate the Compton edge rapidly, linear extrapolation of the linear part of the discrimination curve towards its intersection with the X axis is recommended. Special measurements have shown that the calibration results do not practically depend on the distance between the cathode of a photomultiplier and the place where collimated γ-radiation of the calibration source reaches the scintillator

  16. Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol

    Science.gov (United States)

    Amaro, F. D.; Monteiro, C. M. B.; dos Santos, J. M. F.; Antognini, A.

    2017-01-01

    The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the illicit transport of nuclear material, of which neutron detectors are key components. 3He is very rare and during the last decade this gas has become increasingly difficult to acquire. With the exception of BF3, which is toxic, no other gas can be used for neutron detection in proportional counters. We present an alternative where the 3He atoms are replaced by nanoparticles made of another neutron sensitive material, 10B. The particles are dispersed in a gaseous volume, forming an aerosol with neutron sensitive properties. A proportional counter filled with such aerosol was exposed to a thermal neutron beam and the recorded response indicates that the neutrons have interacted with the particles in the aerosol. This original technique, which transforms a standard proportional gas mixture into a neutron sensitive aerosol, is a breakthrough in the field of radiation detection and has the potential to become an alternative to the use of 3He in proportional counters. PMID:28181520

  17. Development of a 144-channel Hybrid Avalanche Photo-Detector for Belle II ring-imaging Cherenkov counter with an aerogel radiator

    Energy Technology Data Exchange (ETDEWEB)

    Nishida, S., E-mail: shohei.nishida@kek.jp [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Adachi, I. [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Hamada, N. [Toho University, Funabashi (Japan); Hara, K. [High Energy Accelerator Research Organization (KEK), Tsukuba (Japan); Iijima, T. [Nagoya University, Nagoya (Japan); Iwata, S.; Kakuno, H. [Tokyo Metropolitan University, Hachioji (Japan); Kawai, H. [Chiba University, Chiba (Japan); Korpar, S.; Krizan, P. [Jozef Stefan Institute, Ljubljana (Slovenia); Ogawa, S. [Toho University, Funabashi (Japan); Pestotnik, R.; Ŝantelj, L.; Seljak, A. [Jozef Stefan Institute, Ljubljana (Slovenia); Sumiyoshi, T. [Tokyo Metropolitan University, Hachioji (Japan); Tabata, M. [Chiba University, Chiba (Japan); Tahirovic, E. [Jozef Stefan Institute, Ljubljana (Slovenia); Yoshida, K. [Tokyo Metropolitan University, Hachioji (Japan); Yusa, Y. [Niigata University, Niigata (Japan)

    2015-07-01

    The Belle II detector, a follow up of the very successful Belle experiment, is under construction at the SuperKEKB electron–positron collider at KEK in Japan. For the PID system in the forward region of the spectrometer, a proximity-focusing ring-imaging Cherenkov counter with an aerogel radiator is being developed. For the position sensitive photon sensor, a 144-channel Hybrid Avalanche Photo-Detector has been developed with Hamamatsu Photonics K.K. In this report, we describe the specification of the Hybrid Avalanche Photo-Detector and the status of the mass production.

  18. Development of aerogel Cherenkov counters at Novosibirsk

    International Nuclear Information System (INIS)

    Barnyakov, A.Yu.; Barnyakov, M.Yu.; Baehr, J.; Bellunato, T.; Beloborodov, K.I.; Bobrovnikov, V.S.; Buzykaev, A.R.; Calvi, M.; Danilyuk, A.F.; Djordjadze, V.; Golubev, V.B.; Kononov, S.A.; Kravchenko, E.A.; Lipka, D.; Matteuzzi, C.; Musy, M.; Onuchin, A.P.; Perego, D.; Rodiakin, V.A.; Savinov, G.A.; Serednyakov, S.I.; Shamov, A.G.; Stephan, F.; Tayursky, V.A.; Vorobiov, A.I.

    2006-01-01

    The work on aerogel Cherenkov counters was started in Novosibirsk in 1986. Production of aerogels with refractive indices of 1.006-1.13 and thicknesses of blocks up to 50mm was developed. The light absorption length at 400nm is 5-7m, the scattering length is 4-5cm. By these parameters, the Novosibirsk aerogel is one of the best in the world. The ASHIPH Cherenkov counters with light collection on wavelength shifters have been developed. The ASHIPH system of the KEDR detector contains 1000l of aerogel. The π/K separation is 4.5σ. A project of ASHIPH counters for the SND detector has been developed. Aerogel RICH for LHCb gives a possibility to identify hadrons in the momentum range of 2-10GeV/c. The Novosibirsk group is developing an aerogel RICH for the endcap for the SuperBaBar project. Calculations performed by a group of physicists from Novosibirsk and DESY-Zeuthen have shown that aerogel radiators enable to achieve time resolution up to 20fs

  19. Resonance Counters as the Best Tool for the Investigations in Material Science

    International Nuclear Information System (INIS)

    Belyaev, A. A.; Irkaev, S. M.; Panchuck, V. V.; Semenov, V. G.; Volodin, V. S.

    2008-01-01

    Sensitivity and resolution play a crucial role when Moessbauer spectroscopy is used in the materials science. Application of resonance counters in Moessbauer spectrometers allows us to increase the parameters mentioned above, and also signal-to-noise ratio considerably. The last one provides diminishing the time needed for obtaining given statistical accuracy. We carried out investigations of development of optimal counters for following isotopes: 57 Fe, 119 Sn, and 151 Eu. Influence of different parameters of resonant radiation converters on experimental results was considered theoretically. Optimization of design has been performed using mathematical modeling based on Monte-Carlo method. Comparison of different types of counters used for resonant detecting was carried out. Results of experimental works on selection of efficient radiation converters are given. Comparison of scintillation and gas resonance counters was carried out. FeAl and FeGe 2 alloys and K 2 MgFe(CN) 6 have been used as converters for experiments with 57 Fe-isotope, CaSnO 3 has been used for 119 Sn and Eu 2 O 3 and EuF 3 --for 151 Eu isotope. Gamma-optical scheme for versatile spectrometer, which expands the range of application of resonant detection for other Moessbauer isotopes, was suggested.

  20. Radiation detection systems

    International Nuclear Information System (INIS)

    Rozsa, Sandor

    1989-01-01

    Principles and operation of radiation detectors used for industrial and laboratory radiometric measurements are reviewed. The discussed detector types are as follows: ionization chamber, proportional counter, Geiger-Mueller counter, semiconductor detectors, scintillation counter and scintillators, photomultiplier tube, scintillation spectrometer and scintillation detector with semiconductor light sensor. A brief overview of the detectors of industrial nuclear instruments is also presented. (R.P.) 32 figs.; 3 tabs

  1. Comprehensive applications of the gas flow proportional counters for radiological surveillance

    International Nuclear Information System (INIS)

    Babu, D.A.R.; Raman, Anand; Ashokkumar, P.; Sharma, D.N.

    2008-01-01

    Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 inches diameter filter paper sample counting applications to large area (∼1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow non penetrating type of radiations like alpha and low energy beta particles, Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency ( 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include: a) Multiple sample gross alpha counting system; b) Laundry monitoring system; c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 inches sized filter paper samples routinely used for the purpose. Five numbers of GFPC 's are arranged sequentially coupled to five individual amplifiers - micro controller modules to process the signal from the five counters. The laundry monitor which is micro controller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry, Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A micro controller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and

  2. Nuclear Forensics and Radiochemistry: Radiation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Rundberg, Robert S. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-08

    Radiation detection is necessary for isotope identification and assay in nuclear forensic applications. The principles of operation of gas proportional counters, scintillation counters, germanium and silicon semiconductor counters will be presented. Methods for calibration and potential pitfalls in isotope quantification will be described.

  3. Nuclear Forensics and Radiochemistry: Radiation Detection

    International Nuclear Information System (INIS)

    Rundberg, Robert S.

    2017-01-01

    Radiation detection is necessary for isotope identification and assay in nuclear forensic applications. The principles of operation of gas proportional counters, scintillation counters, germanium and silicon semiconductor counters will be presented. Methods for calibration and potential pitfalls in isotope quantification will be described.

  4. Background compensated GM counter for the measurement of low level #betta#-activity

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1983-01-01

    When low level activity of a #betta#-ray source or surface contamination is to be measured with a GM counter, it is desirable to obtain a net count without background count through a single measurement. An end-window GM counter for such a purpose was constructed. The counter has a diaphragm to divide it into two parts. The front part, the window side, can detect #betta#-rays and background radiations, while the rear part only detects background, since #betta#-rays coming through the front are absorbed by the diaphragm. In the counter type I, the sensitive volumes of the two parts are the same and the anode wire of the front is connected to that of the rear through an electric resistor which leads to yielding different pulse heights and rise times. The net count of #betta#-rays can be obtained through a single measurement by subtracting the count in the rear part from that in the front part. In the counter type II, the lengths of the anode wires of the two parts are different, which gives rise to different pulse heights. With a background compensated GM counter, it is possible to shorten the measuring time, keeping nearly the same accuracy compared with a conventional GM counter. (orig.)

  5. Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    The Cherenkov counter described for use at Isabelle is a threshold counter in which light is focussed on phototubes. The counter is applicable in large-angle, small-aperture magnetic spectrometers for measurement of particle yields at large p/sub T/. Three of these counters will provide complete π-K-p separation in the range of 7-20 GeV/c. Other Cherenkov counters are discussed and a bibliography of relevant literature on the counters utilizing photoionization is included

  6. Radiation detection and measurement

    International Nuclear Information System (INIS)

    Knoll, G.F.

    1979-01-01

    Introductory material covers radiation sources, radiation interactions, general properties of radiation detectors, and counting statistics and error prediction. This is followed by detailed sections on gas-filled detectors, scintillation counters, semiconductor detectors, neutron detectors and spectroscopy, detector electronics and pulse processing, and miscellaneous radiation detectors and applications

  7. Multimode pulse counter

    International Nuclear Information System (INIS)

    Natanzon, D.D.

    1982-01-01

    A pulse counter with code conversion is described. The counter is based on the integrated circuits of direct-counting devices of medium integration. The counter ensures various modes of pulse counting depending on the logical control signals: reversible, two-channel summing, one-channel summing binary, summing with ''storage'' signal code fixation without interrupting pulse counting. Arrangement of the suggested structure as a microcircuit of medium integration might contribute to reduction in the counter type nomenclature in digital families of widely used integrated circuits

  8. Promotion of radiation peroxidation in models of lipid membranes by caesium and rubidium counter-ions: micellar linolenic acids

    Energy Technology Data Exchange (ETDEWEB)

    Raleigh, J A; Kremers, W [Atomic Energy of Canada Ltd., Pinawa, Manitoba. Whiteshell Nuclear Research Establishment

    1978-11-01

    Caesium and rubidium counter-ions increase peroxidation in irradiated micelles of linoleic (18 : 2) and linolenic (18 :3) acids. The effect was specific to Cs/sup +/ and Rb/sup +/ in the alkali metal series. The effect was independent of the salts used (Cl/sup -/, NO/sub 3//sup -/, Cl0/sub 4//sup -/) and, therefore, independent of the chaotropic nature, and reactivity with hydroxyl radicals of Cl/sup -/, NO/sub 3//sup -/ and ClO/sub 4//sup -/. The promotion of peroxidation by Cs/sup +/ and Rb/sup +/ is interpreted in terms of their effect on fatty acid micelle structure. The dependence of radiation peroxidation on lipid structure in the micelles may be significant for studies of peroxidation in highly structured cell membranes.

  9. Radiation physics, biophysics, and radiation biology

    International Nuclear Information System (INIS)

    Hall, E.J.

    1992-05-01

    The following research programs from the Center for Radiological Research of Columbia University are described: Design and development of a new wall-less ultra miniature proportional counter for nanodosimetry; some recent measurements of ionization distributions for heavy ions at nanometer site sizes with a wall-less proportional counter; a calculation of exciton energies in periodic systems with helical symmetry: application to a hydrogen fluoride chain; electron energy-loss function in polynucleotide and the question of plasmon excitation; a non-parametric, microdosimetric-based approach to the evaluation of the biological effects of low doses of ionizing radiation; high-LET radiation risk assessment at medium doses; high-LET radiobiological effects: increased lesion severity or increased lesion proximity; photoneutrons generated by high energy medical linacs; the biological effectiveness of neutrons; implications for radiation protection; molecular characterization of oncogenes induced by neutrons; and the inverse dose-rate effect for oncogenic transformation by charged particles is LET dependent

  10. The DIRC counter: A new type of particle identification device for B factories

    International Nuclear Information System (INIS)

    Coyle, P.; Lu, A.

    1992-07-01

    A very thin, solid radiator, totally internally reflecting, imaging Cherenkov counter (DIRC) is described. this device is well matched to the hadronic charged particle identification requirements at an asymmetric e + e - B Factory

  11. The DIRC counter: A new type of particle identification device for B factories

    International Nuclear Information System (INIS)

    Ratcliff, B.

    1993-01-01

    A very thin, solid radiator, totally internally reflecting, imaging Cherenkov counter (DIRC) is described. This device is well matched to the hadronic charged particle identification requirements at an asymmetric e + e - B Factory

  12. Position-sensitive proportional counter with low-resistance metal-wire anode

    International Nuclear Information System (INIS)

    Kopp, M.K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which uses a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counther. A pair of specially designed activecapacitance preamplifiers terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, lownoise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at te anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates

  13. Charged particle counters in the pre-modern period

    International Nuclear Information System (INIS)

    Beringer, R.

    1979-01-01

    The history of nuclear particle and radiation counting techniques divides itself naturally into three epochs that may be labeled: Early, Pre-Modern, and Modern. The Pre-Modern era is designated as the period starting in the 1930's during which the several types of gas-ionization counters of the Early period were perfected and coupled to vacuum tube circuits and recording apparatus. These developments are briefly discussed. (Auth.)

  14. Nuclear radiation detector. Realization and study of the G.M. counters with halogens, the multiples anodes

    International Nuclear Information System (INIS)

    Sekhavat, A.

    1975-01-01

    A substantial improvement of the halogene GEIGER-MULLER counters properties has been carried out by the research of new anode forms. This amelioration has been revealed by the comparison of the new counters with the classical ones, absolutely identical as to their size and production. The anodes alone are different

  15. Potential radiation doses likely to be received by the radiologists and paramedical staff in typical hospital in Pakistan (GM counter, survey meter measurements) (abstract)

    International Nuclear Information System (INIS)

    Ali, A.; Zeb, J.; Iqbal, S.; Orfi, S.D.

    1998-01-01

    Potential radiation doses likely to be received by the radiologists and para medical staff in a typical hospital in Pakistan have been measured using a very sensitive radiation survey meter (FAG FH40F2) employing a Geiger Muller counter (FHZ120) as a probe which is a probe extend able up to 4 meters in length. These measurements have been compared with internationally accepted Maximum Permissible Radiation Dose Level (MPDL). Radiation dose rates measured on the hands of two radiologists during fluoroscopy examination of the patient were of the order of 1mSv.h/sup -1/ and 540 mu Sv.h/sup -1/ which were 400% to 216% times higher than the MPDL (250 mu Sv.h/sup -1/). Radiation dose rates measured on the chest and neck were 300 and 50 mu Sv.h/sup -1/, which were 3000% to 500% times higher than those of MPDL (10 mu Sv.h/sup -1/. Such high dose rates present a serious situation and deserve attention of the hospital management and of national regulatory authority so as to minimize the potential radiation doses to the radiologists and para medical staff. As Low As Reasonably Achievable (ALARA) concept should be implemented in the health sector. (author)

  16. Application of solid dosimeter to radiation control

    International Nuclear Information System (INIS)

    Tsujimoto, Tadashi

    1988-01-01

    Individual exposure dose measuring devices are used to measure the dose of each person in facilities using radiations. Major devices of this type currently used in Japan include the film badge, thermoluminescence dosimeter, portable radiation dosimeter and fluorescent glass dosimeter. All of these devices except the portable radiation dosimeter are of a solid type. Various portable-type spatial dose rate measuring devices, generally called survey meters, are available to determine the spatial distribution of radiations. Major survey meters incorporates an ionization chamber, GM counter tube or scintillation counter, while BF 3 counting tubes are available for neutron measurement. Of these, the scintillation dosimeter is of a solid type. A new scintillation survey meter has recently been developed which incorporated a discrimination bias modulation circuit. Dosimeters incorporating an ionization chamber or a GM counter tube are generally used as portable alarms. Recently, a new solid-type alarm has been developed which incorporates a solicon radiation detector. Microcomputers are also used for self-diagnosis, data processing, automatic calibration, etc. (Nogami, K.)

  17. Potential radiation doses likely to be received by the radiologists and para medical staff in an hospital in Pakistan. (G. M. counter, survey meter measurements )

    International Nuclear Information System (INIS)

    Ali, A.; Zeb, J.; Iqbal, S.; Orfi, S.D.

    1999-01-01

    Potential radiation doses likely to received by the radiologists and paramedical staff in a typical hospital in Pakistan have been measured using a very sensitive radiation survey meter (FAG FH40F2) employing in Geiger Muller counter (FHZ 120] as a role which is extendable up to 4 meters in length. The measurements have been compared with internationally accepted Maximum Permissible Radiation Dos Level (MPDL). Radiation dose rates measured on the hands of two radiologist during fluoroscopy examination of the patient were of the order of 1 m Sv.h/sup -1/ and 540 u Sv. h/sup -1/ which were 400% to 21% higher than the MPDL (250 u Sv. h/sup -1/). Radiation dose rates measured on the chest of the nurses were 300 and 50 u Sv. h/sup -1/, which were 3000% to 500% higher than those of MPDL(10 u Sv. h/sup -1/). Such high dose rates present a serious situation from radiation damage point of view and deserve attention of the hospital management and of national regulatory authority so as to minimize the potential radiation doses to the radiologists and paramedical staff. As Low As Reasonably Achievable (ALARA) concept should be implemented in the health sector. (author)

  18. Frequency-tuned microwave photon counter based on a superconductive quantum interferometer

    Science.gov (United States)

    Shnyrkov, V. I.; Yangcao, Wu; Soroka, A. A.; Turutanov, O. G.; Lyakhno, V. Yu.

    2018-03-01

    Various types of single-photon counters operating in infrared, ultraviolet, and optical wavelength ranges are successfully used to study electromagnetic fields, analyze radiation sources, and solve problems in quantum informatics. However, their operating principles become ineffective at millimeter band, S-band, and ultra-high frequency bands of wavelengths due to the decrease in quantum energy by 4-5 orders of magnitude. Josephson circuits with discrete Hamiltonians and qubits are a good foundation for the construction of single-photon counters at these frequencies. This paper presents a frequency-tuned microwave photon counter based on a single-junction superconducting quantum interferometer and flux qutrit. The control pulse converts the interferometer into a two-level system for resonance absorption of photons. Decay of the photon-induced excited state changes the magnetic flux in the interferometer, which is measured by a SQUID magnetometer. Schemes for recording the magnetic flux using a DC SQUID or ideal parametric detector, based on a qutrit with high-frequency excitation, are discussed. It is shown that the counter consisting of an interferometer with a Josephson junction and a parametric detector demonstrates high performance and is capable of detecting single photons in a microwave band.

  19. X-ray polarimetry with a conventional gas proportional counter through rise-time analysis

    CERN Document Server

    Hayashida, K; Tsunemi, H; Torii, K; Murakami, H; Ohno, Y; Tamura, K

    1999-01-01

    We have performed an experiment on the signal rise time of a Xe gas proportional counter using a polarized X-ray beam of synchrotron orbital radiation with energies from 10 to 40 keV. When the counter anode is perpendicular to the electric vector of the incident X-ray photons, the average rise time becomes significantly longer than that for the parallel case. This indicates that the conventional gas proportional counters are useful for X-ray polarimetry. The moderate modulation contrast of this rise-time polarimeter (M=0.1 for 10 keV X-rays and M=0.35 for 40 keV X-rays), with capability of the simultaneous measuring X-ray energies and the timing, would be useful for applications in X-ray astronomy and in other fields.

  20. Detectors for radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Mendez, V.

    1979-09-01

    For our purposes in this review, we note the following points: (1) for charged particle detection, these counters can be filled with any noble gas-quenching gas mixture that produces satisfactory electrical signals; (2) neutron counters, in which the neutrons are detected by their interaction with the specific filling of the chamber to yield an ionizing particle, require special gas mixtures containing /sup 3/He or BF/sub 3/, an alternative approach is to coat the inner surface of the cathode with a boron or lithium compound; (3) proportional counters are used if there is any need to discriminate between different types of radiation incident on the chamber by the magnitude of the ionizing energy retained within the sensitive volume of the counter; (4) proportional counters can operate at higher speeds than Geiger counters, typically up to 10/sup 7/ cts/sec versus less than 10/sup 5//sec for the Geiger counters; and (5) Geiger counters produce very large uniform pulses which can be scaled by very simple electronics, hence, they are often used in survey meters and other portable monitoring instruments.

  1. Application of GM counters in the continuous monitoring of the environment

    International Nuclear Information System (INIS)

    Deme, S.

    1978-01-01

    Around critical nuclear facilities environmental control systems giving continuous information about given spots are applied. Both the fission products and the closed radiation sources released from the facilities can be most efficiently detected by their γ-radiation. From various aspects, the GM-counters proved to be the most suitable detectors for such purposes. Some questions concerning its application are discussed in more detail. The control system elaborated in the Central Research Institute of Physics contains three parallel GM-counters, a ratemeter, a scaler and a printer attached to it. High power can be centrally or locally supplied. In case of more than four measuring channels the application of a simple data collecting equipment with common electronic units is advisable. Programmable data collectors are used when alarm signals are required above a specified level. The dependence of the minimum of the detectable increase of dose rate on several parameters of the measuring system, involving the duration of the measuring cycle are discussed emphasizing the advantages of reversive scelers. (V.N.)

  2. Silica aerogel Cerenkov counter

    International Nuclear Information System (INIS)

    Yasumi, S.; Masaike, A.; Yamamoto, A.; Yoshimura, Y.; Kawai, H.

    1984-03-01

    In order to obtain silica aerogel radiators of good quality, the prescription used by Saclay group has been developed. We have done several experiments using beams from KEK.PS to test the performance of a Cerenkov counter with aerogel modules produced in KEK. It turned out that these modules had excellent quality. The production rate of silica aerogel in KEK is 15 -- 20 litres a week. Silica aerogel modules of 20 x 10 x 3 cm 3 having the refractive index of 1.058 are successfully being used by Kyoto University group in the KEK experiment E92 (Σ). Methodes to produce silica aerogel with higher refractive index than 1.06 has been investigated both by heating an module with the refractive index of 1.06 and by hydrolyzing tetraethyl silicate. (author)

  3. Space and power efficient hybrid counters array

    Science.gov (United States)

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  4. Radiation Therapy (For Parents)

    Science.gov (United States)

    ... dose given. Radiation on the brain may affect learning and memory. Your doctor can offer advice and may prescribe medications to make your child more comfortable during radiation treatment. Make sure you avoid giving your child any medicines, including herbal medicines or over-the-counter (OTC) ...

  5. Detection of {alpha} particles with the aid of a fluorescence counter; Detection des particules {alpha} a l'aide d'un compteur a fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Koechlin, Y

    1951-07-01

    The operation principle of the fluorescence counter, used as {alpha} particles detector, is analyzed in the first part. Detection can be done in two ways: by counting the pulses due to each {alpha} particle, or by integrating all pulses and measuring the average current obtained. In the second part, three series of measurements are presented: 1 - two fluorescent substances (zinc sulfate and anthracene) are placed in front of the photocathode of three types of photomultipliers (RCA 931A, EMI 4588, and EMI 5311). These substances are bombarded with the {alpha} radiations of a Po source and then irradiated by the {beta} and {gamma} radiations of a Ra source in order to study the light emission of these thin film substances when submitted to the three types of radiations. The results show that thanks to the amplitude of the emitted light pulses, the fluorescence counter, when submitted to the three types of radiations, allows to distinguish between the {alpha} radiations of the polonium and the {beta} and {gamma} radiations of the radium source. The output current of a 931A, when measured with a galvanometer, allows to detect Po sources with an intensity of about 10{sup -6} curie. This is observed when its photocathode receives the light from a ZnS-Ag coating bombarded by the {alpha} particles of Po. The quantum efficiency of the counter is close to 100% for the {alpha} particles of Po. This efficiency is evaluated by comparison with the efficiency of a thin wall Geiger-Mueller counter. Moreover, when a thin crystal of anthracene is used as detector, the energy of the incident particles can be measured with a 2% preciseness. (J.S.)

  6. Geiger-mueller radiation detector with means for detecting and indicating the existence of radiation overload

    International Nuclear Information System (INIS)

    Kovacs, T.; Mills, A.P.; Pfeiffer, L.N.

    1981-01-01

    When subjected to radiation overload existing geiger-mueller counters may give an erroneously low reading, resulting in possible hazard to personnel. The instant invention discloses simple and inexpensive apparatus to remedy this dangerous shortcoming. Depending on the geometry of the detector tube, two possible failure modes have been identified, and circuitry is disclosed to detect the existence of these respective failure modes. The disclosed apparatus indicates the absence of an overload condition, in addition to signaling, by both visible and audible means, the existence of excessive radiation that might result in erroneously low reading of the geiger-mueller counter

  7. Development of personnel dose control system and whole body counter system

    International Nuclear Information System (INIS)

    Ooki, Yasushi; Harato, Kenji

    2005-01-01

    We delivered Personnel Dose Control System to Higashidohri nuclear plant of Tohoku Electric Power Company, in November 2004. In this system development, we automated the registration of radiation worker with close link between this system and Whole Body Counter System. In addition, this system enables the user to reduce workload for accumulation and notification of personal exposure data, because we adopted the system to extract the data effectively operating the terminal PC which the associate company gets ready in their office. We also delivered Whole body Counter System in December 2004, which was developed to measure internal exposure without feeling of oppression in chair-style device for the first time in Japan. This system enables non-operator system for measurement allowing workers to operate by themselves. (author)

  8. A low-level needle counter

    International Nuclear Information System (INIS)

    Fujita, Y.; Taguchi, Y.; Imamura, M.; Inoue, T.; Tanaka, S.

    1977-01-01

    A small end-window type gas-flow counter which has a sharpened needle (anode) against the end-window plane (cathode) was developed for low-level counting of β particles to the amount of less than one count per hour in solid sources of relatively high specific activity. The advantage of the needle counter for low-level work is that being of a conical shape the active volume as against the window area is small. The background count rate of 0.0092+-0.0005 cpm was obtained for a 10 mm dia needle counter operating in GM mode and in anticoincidence with a well-type NaI(Tl) guard crystal with massive shields. The counter design and the counter characteristics are presented in detail. The needle counter is simple in design, low-cost and stable in long time operation. (author)

  9. Detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    All detection or measurement of radiation rests in the possibility of recognizing the interactions of radiation with matter. When radiation passes through any kind of material medium, all or a portion of its energy is transferred to this medium. This transferred energy produces an effect in the medium. In principle, the detection of radiation is based on the appearance and the observation of this effect. In theory, all of the effects produced by radiation may be used in detecting it: in practice, the effects most commonly employed are: (1) ionization of gases (gas detectors), or of some chemical substance which is transformed by radiation (photographic or chemical dosimeters); (2) excitations in scintillators or semiconductors (scintillation counters, semiconductor counters); (3) creation of structural defects through the passage of radiation (transparent thermoluminescent and radioluminescent detectors); and (4) raising of the temperature (calorimeters). This study evaluates in detail, instruments based on the ionization of gases and the production of luminescence. In addition, the authors summarize instruments which depend on other forms of interaction, used in radiation medicine and hygiene (radiology, nuclear medicine)

  10. Counter-discourse in Zimbabwean literature

    NARCIS (Netherlands)

    Mangena, Tendai

    2015-01-01

    Counter-Discourse in Zimbabwean Literature is a study of specific aspects of counter-discursive Zimbabwean narratives in English. In discussing the selected texts, my thesis is based on Terdiman’s (1989) the postcolonial concept of counter-discourse. In Zimbabwean literature challenges to a dominant

  11. The suppression of destructive sparks in parallel plate proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Cockshott, R.A.; Mason, I.M.

    1984-02-01

    The authors find that high energy background events produce localised sparks in parallel plate counters when operated in the proportional mode. These sparks increase dead-time and lead to degradation ranging from electrode damage to spurious pulsing and continuous breakdown. The problem is particularly serious in low energy photon detectors for X-ray astronomy which are required to have lifetimes of several years in the high radiation environment of space. For the parallel plate imaging detector developed for the European X-ray Observatory Satellite (EXOSAT) they investigate quantitatively the spark thresholds, spark rates and degradation processes. They discuss the spark mechanism, pointing out differences from the situation in spark chambers and counters. They show that the time profile of the sparks allows them to devise a spark suppression system which reduces the degradation rate by a factor of ''200.

  12. Ionizing radiations, detection, dosimetry, spectrometry

    International Nuclear Information System (INIS)

    Blanc, D.

    1997-10-01

    A few works in French language are devoted to the detection of radiations. The purpose of this book is to fill a gap.The five first chapters are devoted to the properties of ionizing radiations (x rays, gamma rays, leptons, hadrons, nuclei) and to their interactions with matter. The way of classification of detectors is delicate and is studied in the chapter six. In the chapter seven are studied the statistics laws for counting and the spectrometry of particles is treated. The chapters eight to thirteen study the problems of ionization: charges transport in a gas, ionization chambers (theory of Boag), counters and proportional chambers, counters with 'streamers', chambers with derive, spark detectors, ionization chambers in liquid medium, Geiger-Mueller counters. The use of a luminous signal is the object of the chapters 14 to 16: conversion of a luminous signal in an electric signal, scintillators, use of the Cerenkov radiation. Then, we find the neutron detection with the chapter seventeen and the dosimetry of particles in the chapter eighteen. This book does not pretend to answer to specialists questions but can be useful to physicians, engineers or physics teachers. (N.C.)

  13. A multi purpose 4 π counter spherical ionization chamber type

    International Nuclear Information System (INIS)

    Calin, Marian Romeo; Calin, Adrian Cantemir

    2004-01-01

    A pressurized ionization chamber detector able to measure radioactive sources in internal 2π or 4π geometry was built in order to characterize alpha and beta radioactive sources, i.e. to calibrate these sources by relative method and to test the behavior of gas mixtures in pressurized-gas radiation detectors. The detector we made is of spherical shape and works by collecting in a uniform electric field the ionization charges resulting from the interaction of ionizing radiation with gas in the sensitive volume of the chamber. An ionizing current proportional to the activity of the radioactive source to be measured is obtained. In this paper a gas counter with a spherical symmetry is described. This detector can work in a very satisfactory manner, either as a flow counter or as a ionization chamber reaching in the latter case a good α pulse height resolution, even with large emitting sources. Calculations are made in order to find the dependence of the pulse shape on the direction of emission of an α-particle by a point source in the chamber (finite track). A good agreement is found between these calculations and the experimental tests performed, which show that this dependence can be employed in high efficiency measurements of angular α-γ correlations. (authors)

  14. What is Counter-Enlightenment?

    OpenAIRE

    Darrin M. McMahon

    2017-01-01

    This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlight...

  15. Silicon photomultipliers in AMIGA muon counters

    Energy Technology Data Exchange (ETDEWEB)

    Botti, Ana Martina [Institut fuer Kernphysik, Karlsruher Institut fuer Technologie (Germany); Instituto de Tecnologias en Deteccion y Astroparticulas (ITeDA) (Argentina); Collaboration: Pierre-Auger-Collaboration

    2016-07-01

    The project AMIGA (Auger Muons and Infill for the Ground Array) aims to extend the energy range at the Pierre Auger Observatory to observe cosmic rays of lower energies (down to ∝10{sup 17} eV) and to study the transition from extragalactic to galactic cosmic rays. AMIGA is compounded by an infill of surface detectors (employing Cherenkov radiation detection in water) and muon counters. The AMIGA muon counters consist of an array of buried modules composed of 64 scintillator bars, a multi-pixel Photo Multiplier Tube (PMT) and the corresponding electronic of acquisition which works along with the surface detector. Currently, ITeDA is evaluating the feasibility of replacing PMTs with silicon photomultipliers (SiPM) without performing any substantial modification in the digital readout nor in the mechanical design. I present calibration results of a prototype module associated to the surface detector Toune of the Pierre Auger Observatory using a SiPM Hamamatsu S1257-100C plugged to the standard AMIGA front-end electronics. In addition, a study concerning gain stability and temperature variation has also been performed and is reported. I finally discuss a comparison between traces measured by both photodetectors (PMT and SiPM) for modules associated to the surface detector Toune.

  16. Environmental radiation monitoring of Vizag City

    International Nuclear Information System (INIS)

    Sreekanth, B.; Narsaiah, M.V.R.; Saindane, Shashank; Pujari, Raju; Krishna, N.S.; Sambamurthy, T.; Chaudhury, Probal; Pradeepkumar, K.S.

    2014-01-01

    Radiological impact assessment is to be carried out following any radiological emergency to implement the required counter measures. A ground based environmental radiation monitoring of Vizag city has been carried out by installing various radiation monitoring instruments in a vehicle to generate the base line radiation data. It also helps to check the illicit trafficking of radioactive sources and also identifying the orphan sources. The average background radiation level observed in Vizag city was 80 nGy/h. Database of baseline radiation level with GPS location at all important locations of the whole city has been developed. No illicit trafficking of radioactive materials and orphan sources were detected during the survey. All the detectors used in the survey shown good correlation in their response. The study showed that mobile monitoring methodology will be useful in the quick assessment of radiological impact and strengthens the decision makers in reducing consequences by initiating immediate counter measures

  17. A portable neutron coincidence counter

    Energy Technology Data Exchange (ETDEWEB)

    Peurrung, A.J.; Bowyer, S.M.; Craig, R.A.; Dudder, G.B.; Knopf, M.A.; Panisko, M.E.; Reeder, P.L.; Stromswold, D.C.; Sunberg, D.S.

    1996-11-01

    Pacific Northwest National Laboratory has designed and constructed a prototype portable neutron coincidence counter intended for use in a variety of applications, such as the verification and inspection of weapons components, safety measurements for novel and challenging situations, portable portal deployment to prevent the transportation of fissile materials, uranium enrichment measurements in hard-to-reach locations, waste assays for objects that cannot be measured by existing measurement systems, and decontamination and decommissioning. The counting system weighs less than 40 kg and is composed of parts each weighing no more than 5 kg. In addition, the counter`s design is sufficiently flexible to allow rapid, reliable assembly around containers of nearly arbitrary size and shape. The counter is able to discern the presence of 1 kg of weapons-grade plutonium within an ALR-8 (30-gal drum) in roughly 100 seconds and 10 g in roughly 1000 seconds. The counter`s electronics are also designed for maximum adaptability, allowing operation under a wide variety of circumstances, including exposure to gamma-ray fields of 1 R/h. This report provides a detailed review of the design and construction process. Finally, preliminary experimental measurements that confirm the performance capabilities of this counter are discussed. 6 refs., 18 figs., 3 tabs.

  18. CEDAR counter (internal part)

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    Here on the mounting bench. The counter is a differential Cerenkov, corrected for chromaticity, able to differentiate pions from kaons up to 350 GeV. Counters of this type were used in all SPS hadron beams.

  19. gamma. radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1948-12-08

    Following the work of Ward (Proc Cambridge Phil Soc 35 322(1939)), the ..gamma..-radiation of ionium (from an IoTh preparation) was studied with the aid of Ta and W screens, and an aluminum counter. The screen measurements confirmed Ward's findings of two radiations, of 68 keV and of about 200 keV. The number of quanta per second of each radiation was determined with the counter, which has been calibrated on certain L lines of radium. The global quanta number of L lines of ionium was also determined. The results were as follows: 0.7 quanta ..gamma.. of 68 keV for 100 ..cap alpha..-particles; 0.2 quanta ..gamma.. of 200 keV for 100 ..cap alpha..-particles; 10 quanta L for 100 ..cap alpha..-particles. These data, which show an important internal conversion, agree with the findings of Teillac (Compt Rend 227 1227 (1948)), who investigated the ..beta..-radiation of ionium. It is the radiation 68 keV which is highly converted. On the other hand, these results do no agree with the data on the fine structure of ionium found by Rosenblum, Valadares, and Vial (Compt Rend 227 1088(1948)).

  20. Over-the-Counter Medicines

    Science.gov (United States)

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. ... medicine is safe enough to sell over-the-counter. Taking OTC medicines still has risks. Some interact ...

  1. Rate dependent image distortions in proportional counters

    International Nuclear Information System (INIS)

    Trow, M.W.; Bento, A.C.; Smith, A.

    1994-01-01

    The positional linearity of imaging proportional counters is affected by the intensity distribution of the incident radiation. A mechanism for this effect is described, in which drifting positive ions in the gas produce a distorting electric field which perturbs the trajectories of the primary electrons. In certain cases, the phenomenon causes an apparent improvement of the position resolution. We demonstrate the effect in a detector filled with a xenon-argon-CO 2 mixture. The images obtained are compared with the results of a simulation. If quantitative predictions for a particular detector are required, accurate values of the absolute detector gain, ion mobility and electron drift velocity are needed. ((orig.))

  2. A Neutron Rem Counter

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J

    1964-01-15

    A neutron detector is described which measures the neutron dose rate in rem/h independently of the energy of the neutrons from thermal to 15 MeV. The detector consists of a BF{sub 3} proportional counter surrounded by a shield made of polyethylene and boron plastic that gives the appropriate amount of moderation and absorption to the impinging neutrons to obtain rem response. Two different versions have been developed. One model can utilize standard BF{sub 3} counters and is suitable for use in installed monitors around reactors and accelerators and the other model is specially designed for use in a portable survey instrument. The neutron rem counter for portable instruments has a sensitivity of 2.4 cps/mrem/h and is essentially nondirectional in response. With correct bias setting the counter is insensitive to gamma exposure up to 200 r/h from Co-60.

  3. An electron counting mechanism for the open counter operated in air

    International Nuclear Information System (INIS)

    Noguchi, T.; Nagashima, S.; Uda, M.

    1994-01-01

    An electron counting mechanism for an open or air filled counter has been explicitly explained for the first time. Electrons emitted from a solid surface or formed in air by radiations are transported to the neighborhood of the anode in the counter in the form of O 2 - ions, and are detached from the ions and multiplied in the proximity to the anode through electronic avalanche process. The estimation of the number of the emitted electrons from observed count rates has successively been performed by expressing the dead time as the sum of time intervals necessary for quenching using an external circuit and for drifting of the O 2 - ions, and also by taking into account the reduction in the number of electrons during transportation, which is due to scattering of the O 2 - ions in air. (orig.)

  4. Permanently calibrated interpolating time counter

    International Nuclear Information System (INIS)

    Jachna, Z; Szplet, R; Kwiatkowski, P; Różyc, K

    2015-01-01

    We propose a new architecture of an integrated time interval counter that provides its permanent calibration in the background. Time interval measurement and the calibration procedure are based on the use of a two-stage interpolation method and parallel processing of measurement and calibration data. The parallel processing is achieved by a doubling of two-stage interpolators in measurement channels of the counter, and by an appropriate extension of control logic. Such modification allows the updating of transfer characteristics of interpolators without the need to break a theoretically infinite measurement session. We describe the principle of permanent calibration, its implementation and influence on the quality of the counter. The precision of the presented counter is kept at a constant level (below 20 ps) despite significant changes in the ambient temperature (from −10 to 60 °C), which can cause a sevenfold decrease in the precision of the counter with a traditional calibration procedure. (paper)

  5. New developments in radiation protection instrumentation via active electronic methods

    International Nuclear Information System (INIS)

    Umbarger, C.J.

    1981-01-01

    New developments in electronics and radiation detectors are improving on real-time data acquisition of radiation exposure and contamination conditions. Recent developments in low power circuit designs, hybrid and integrated circuits, and microcomputers have all contributed to smaller and lighter radiation detection instruments that are, at the same time, more sensitive and provide more information (e.g., radioisotope identification) than previous devices. New developments in radiation detectors, such as cadmium telluride, gas scintillation proportional counters, and imaging counters (both charged particle and photon) promise higher sensitivities and expanded uses over present instruments. These developments are being applied in such areas as health physics, waste management, environmental monitoring, in vivo measurements, and nuclear safeguards

  6. Charge and velocity resolution of Cerenkov counters in a beam of accelerated heavy nuclei

    International Nuclear Information System (INIS)

    Cantin, M.; Goret, P.; Jorrand, J.; Jouan, R.; Juliusson, E.; Koch, L.; Maubras, Y.; Mestreau, P.; Petrou, N.; Rio, Y.; Soutoul, A.; Cawood, P.; Linney, A.

    1975-01-01

    The response of various Cerenkov radiators to oxygen and nitrogen nuclei with energies ranging between 2.1GeV/n and 300MeV/n is presented. The velocity and charge resolutions are analyzed in relation to the possible use of these counters for chemical and isotopic analysis of the primary cosmic ray nuclei [fr

  7. What is Counter-Enlightenment?

    Directory of Open Access Journals (Sweden)

    Darrin M. McMahon

    2017-02-01

    Full Text Available This article counters recent suggestions that there was no such thing as a “Counter-Enlightenment” or “Counter-Enlightenments,” and that such terms ought thus to be abandoned.   While acknowledging inevitable difficulties with the terms, the article argues that there can be no doubting the reality.   European countries faced a variety of vehement and self-conscious movements that defined themselves precisely through their opposition to what they took to be the corrosive effects of the Enlightenment.  In the process, they defined the main terms of an enduring vision of the world that we now associate with the Right.

  8. Numerical model of thyroid counter

    Directory of Open Access Journals (Sweden)

    Szuchta Maciej

    2016-03-01

    Full Text Available The aim of this study was to develop a numerical model of spectrometric thyroid counter, which is used for the measurements of internal contamination by in vivo method. The modeled detector is used for a routine internal exposure monitoring procedure in the Radiation Protection Measurements Laboratory of National Centre for Nuclear Research (NCBJ. This procedure may also be used for monitoring of occupationally exposed nuclear medicine personnel. The developed model was prepared using Monte Carlo code FLUKA 2011 ver. 2b.6 Apr-14 and FLAIR ver. 1.2-5 interface. It contains a scintillation NaI(Tl detector, the collimator and the thyroid water phantom with a reference source of iodine 131I. The geometry of the model was designed and a gamma energy spectrum of iodine 131I deposited in the detector was calculated.

  9. Nuclear timer/counter

    International Nuclear Information System (INIS)

    Wuthayavanich, S.

    1978-01-01

    This thesis represents the development of a Timer/COUNTER compatible to the standard Nuclear Instrument Module Specifications. The unit exhibits high accuracy, light weight and ease of maintenance. The unit also has a built-in precision discriminator to discriminate unwanted signals that may cause interference in counting. With line frequency time base the timer can be preset in steps from 0.1 sec. to 9 x 10 5 min. The counter with six digits miniature display and an overflow output has a maximum counting rate of 10 MHz. The accumulated counting data can be transferred to a teletype or printer for hard copy printout with the aid of ORTEC 777 Line Printer or 432 A Print-out Control or any print out interface with input compatible to the print output of the Timer/Counter. Owing to its NIM compatibility the unit is directly powered by the NIM power supply

  10. A compact and high efficiency GAGG well counter for radiocesium concentration measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Ogata, Yoshimune

    2014-07-01

    After the Fukushima nuclear disaster, social concern about radiocesium ({sup 137}Cs and {sup 134}Cs) contamination in food increased. However, highly efficient instruments that can measure low level radioactivity are quite expensive and heavy. A compact, lightweight, and reliable radiation detector that can inexpensively monitor low level radiocesium is highly desired. We developed a compact and highly efficient radiocesium detector to detect ∼32 keV X-rays from radiocesium instead of high energy gamma photons. A 1-mm thick GAGG scintillator was selected to effectively detect ∼32 keV X-rays from {sup 137}Cs to reduce the influence of ambient radiation. Four sets of 25 mm×25 mm×1 mm GAGG plates, each of which was optically coupled to a triangular-shaped light guide, were optically coupled to a photomultiplier tube (PMT) to form a square-shaped well counter. Another GAGG plate was directly optically coupled to the PMT to form its bottom detector. The energy resolution of the GAGG well counter was 22.3% FWHM for 122 keV gamma rays and 32% FWHM for ∼32 keV X-rays. The counting efficiency for the X-rays from radiocesium (mixture of {sup 137}Cs and {sup 134}Cs) was 4.5%. In measurements of the low level radiocesium mixture, a photo-peak of ∼32 keV X-rays can clearly be distinguished from the background. The minimum detectable activity (MDA) was estimated to be ∼100 Bq/kg for 1000 s measurement. The results show that our developed GAGG well counter is promising for the detection of radiocesium in food.

  11. The first CEDAR counter

    CERN Multimedia

    CERN PhotoLab

    1976-01-01

    The first differential Cerenkov counter with chromatic corrections (called CEDAR) successfully tested at the PS in July 75. These counters were used in the SPS hadronic beams for particle identification. Some of the eight photomultipliers can be seen: they receive the light reflected back through the annular diaphragm. René Maleyran stands on the left.

  12. Recent results from the DELPHI barrel ring imaging Cherenkov counter

    International Nuclear Information System (INIS)

    Anassontzis, E.G.; Ioannou, P.; Kalkanis, G.; Katsanevas, S.; Kontaxis, I.; Kourkoumelis, C.; Nounos, S.; Preve, P.; Resvanis, L.K.; Brunet, J.M.; Dolbeau, J.; Guglielmo, L.; Ledroit, F.; Poutot, D.; Tristram, G.

    1991-01-01

    The DELPHI detector, installed at LEP, is equipped with RICH (Ring Imaging Cherenkov) counters. The Barrel part incorporates a liquid (C 6 F 14 ) and a gaseous (C 5 F 12 ) radiator providing particle identification up to 20GeV/c. The Cherenkov protons of both radiators are detected by TPC-like photon detectors. The drift gas (75% CH 4 + 25% C 2 H 6 ) is doped with TMAE, but which the UV Cherenkov photons are converted into single free photo-electrons. These are drifted towards MWPC's at the end of the drift tubes and the space coordinates of the conversion point are determined. One half of the Barrel RICH is now equipped with drift tubes and has provided results from the liquid radiator since spring 1990. The gas radiator has been tested with C 2 F 6 as a preliminary filling since August 1990. The data obtained demonstrate the good particle identification potential. For the liquid radiator the number of detected photons per ring in hadron jets is N=8, whereas for muon pairs (single tracks) N=10 has been obtained. For the gas radiator 2.1 photons per track were observed, which demonstrates the good functioning of the focussing mirrors, as the C 2 F 6 this is close to the expected value

  13. Silica aerogel threshold Cherenkov counters for the JLab Hall A spectrometers: improvements and proposed modifications

    CERN Document Server

    Lagamba, L; Colilli, S; Crateri, R; De Leo, R; Frullani, S; Garibaldi, F; Giuliani, F; Gricia, M; Iodice, M; Iommi, R; Leone, A; Lucentini, M; Mostarda, A; Nappi, E; Perrino, R; Pierangeli, L; Santavenere, F; Urciuoli, G M

    2001-01-01

    Recently approved experiments at Jefferson Lab Hall A require a clean kaon identification in a large electron, pion, and proton background environment. To this end, improved performance is required of the silica aerogel threshold Cherenkov counters installed in the focal plane of the two Hall A spectrometers. In this paper we propose two strategies to improve the performance of the Cherenkov counters which presently use a hydrophilic aerogel radiator, and convey Cherenkov photons towards the photomultipliers by means of mirrors with a parabolic shape in one direction and flat in the other. The first strategy is aerogel baking. In the second strategy we propose a modification of the counter geometry by replacing the mirrors with a planar diffusing surface and by displacing in a different way the photomultipliers. Tests at CERN with a 5 GeV/c multiparticle beam revealed that both the strategies are able to increase significantly the number of the detected Cherenkov photons and, therefore, the detector performan...

  14. Proportional counter end effects eliminator

    International Nuclear Information System (INIS)

    Meekins, J.F.

    1976-01-01

    An improved gas-filled proportional counter which includes a resistor network connected between the anode and cathode at the ends of the counter in order to eliminate ''end effects'' is described. 3 Claims, 2 Drawing Figures

  15. Counter-Narratives and the Unrehearsed Stories Counter-Terrorists Unwittingly Produce

    Directory of Open Access Journals (Sweden)

    Beatrice de Graaf

    2010-11-01

    Full Text Available Governments produce both deliberate and involuntary (and less conscious narratives when countering terrorism. The thesis of this article is that such unintended messages can be much more powerful and consequential than is realized; in fact, they can completely contradict the intended official 'counter-narrative'. To substantiate this hypothesis, the author looks at the experience of the German Federal Republic in the 1970s and beyond when state and society were confronted with the Red Army Faction (RAF and similar left-wing "revolutionaries" like those of the 2nd of June Movement or the Red Zora.

  16. Plea and counter-plea

    International Nuclear Information System (INIS)

    1979-06-01

    The bulk of papers written during the hearing 'Plea and counter-plea', the so-called 'Gorleben hearing', which was held from 28th March until 3rd April 1979, comprises ca. 4,200 pages. It consists of the written comments put forward by the critics of nuclear energy, the minutes of the hearing as well as the supplementary statements of the counter-critics. This report is trying to confront those essential objections made by the critics which put in doubt the feasibility of a fuel-cycle centre with regard to safety engineering with the facts which are considered correct from the view of the DWK. The oral and written explanations of the counter-critics are particularly referred to in this debate. (orig./HP) [de

  17. Multiple channel programmable coincidence counter

    Science.gov (United States)

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  18. Tritium-Powered Radiation Sensor Network

    Science.gov (United States)

    2015-09-01

    Photomultiplier Tube, Scintillator, Geiger counter, Zigbee, Wireless Network, Radiation detector, Dirty Bomb 16. SECURITY CLASSIFICATION OF: 17...operational lifetime of 150 years. Persistent sensing of the environment with vibration and radiation (electromagnetic [ EM ], acoustic, gamma, etc.) in...Transportation E-field electric field EH electron-hole EM electromagnetic GaAs gallium arsenide GPS global positioning system InGaP indium gallium

  19. Aerogel Cherenkov Counters of the KEDR Detector

    CERN Document Server

    Ovtin, I V; Barnyakov, M Y; Bobrovnikov, V S; Buzykaev, A R; Danilyuk, A F; Katcin, A A; Kononov, S A; Kravchenko, E A; Kuyanov, I A; Onuchin, A P; Rodiakin, V A

    2017-01-01

    The particle identification system of the KEDR detector is based on aerogel threshold Cherenkov counters called ASHIPH counters. The system consists of 160 counters arranged in two layers. An event reconstruction program for the ASHIPH system was developed. The position of each counter relative to the tracking system was determined using cosmic muons and Bhabha events. The geometric efficiency of the ASHIPH system was verified with Bhabha events. The efficiency of relativistic particle detection was measured with cosmic muons. A π/K separation of 4δ in the momentum range 0.95 −1.45 GeV/c was confirmed. A simulation program for the ASHIPH counters has been developed.

  20. Crate counter for normal operating loss

    International Nuclear Information System (INIS)

    Harlan, R.A.

    A lithium-loaded zinc sulfide scintillation counter to closely assay plutonium in waste packaged in 1.3 by 1.3 by 2.13m crates was built. In addition to assays for normal operating loss accounting, the counter will allow safeguards verification immediately before shipment of the crates for burial. The counter should detect approximately 10 g of plutonium in 1000 kg of waste

  1. Performance model of metallic concentric tube recuperator with counter flow arrangement

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Harshdeep [HIET, Department of Mechanical Engineering, Ghaziabad, Uttar Pradesh (India); Kumar, Anoop; Goel, Varun [NIT, Department of Mechanical Engineering, Hamirpur, Himachal Pradesh (India)

    2010-03-15

    A performance model for counter flow arrangement in concentric tube recuperator that can be used to utilize the waste heat in the temperature range of 900-1,400 C is presented. The arrangement consists of metallic tubular inner and outer concentric shell with a small annular gap between two concentric shells. Flue gases pass through the inner shell while air passes through the annular gap in the reverse direction (counter flow arrangement). The height of the recuperator is divided into elements and an energy balance is performed on each elemental height. Results give necessary information about surface, gas and air temperature distribution, and the influence of operating conditions on recuperator performance. The recuperative effectiveness is found to be increased with increasing inlet gas temperature and decreased with increasing fuel flow rate. The present model accounts for all heat transfer processes pertinent to a counterflow radiation recuperator and provide a valuable tool for performance considerations. (orig.)

  2. Efficiency determination of whole-body counters by Monte Carlo method, using a microcomputer

    International Nuclear Information System (INIS)

    Fernandes Neto, J.M.

    1987-01-01

    A computing program using Monte Carlo method for calculate the whole efficiency of distributed radiation counters in human body is developed. A simulater of human proportions was used, of which was filled with a known and uniform solution containing a quantity of radioisopes. The 99m Tc, 131 I and 42 K were used in this experience, and theirs activities compared by a liquid scintillator. (C.G.C.) [pt

  3. The counter ion: expanding excipient functionality

    Directory of Open Access Journals (Sweden)

    Shireesh Apte

    2011-06-01

    Full Text Available Excipients have increasingly become 'enablers' of drug delivery and efficacy rather than passive bystanders. Advances in pharmaceutical technology have enabled the ability to deliver specific counter ions (in the form of the counter ion containing excipient and the API simultaneously to preselected targets in the body. This, coupled with a near universal mechanism of columbic interactions that determine the [API- counter ion] efficacy, can be harnessed to exploit this hitherto unavailable or unrecognized enabling mechanism. New excipients may be assembled by a near inexhaustible supply of different permutations of counter ions and their judicious use in specific situations could potentially drive a renaissance in excipient innovation (and drug delivery and efficacy despite regulatory stagnation.

  4. An auto-triggered anode potential lowering method on increase of after-pulses in a GM-counter

    International Nuclear Information System (INIS)

    Igarashi, Ryuji; Narita, Yuichi

    1982-01-01

    The number of after-pulses generated in an organic quenching GM-counter depends on the pulsed radiation intensity, and it can be usable for the intensity measurement. The increase of the number of after-pulse occurrence (occurring rate) per one exposure to pulsed radiation improves the efficiency in intensity measurement, and is effective to the measurement in low intensity region. The attempt to increase the number of after-pulse factors, to hold those in a GM-counter for more than the dead time and further to improve the after-pulse yield is the presently reported auto-triggered anode potential lowering method. In this report, the experimental apparatus and its procedure are described, and the experimental results about the dependence of after-pulse occurring rate are described on the anode potential lowering duration, on the lowered anode potential, on the high anode potential, and on the intensity of pulsed X-ray. The after-pulse occurring rate by this method showed the dependence on radiation intensity in the range from 4.5 x 10 -4 to 1.1 x 10 -2 mu R/burst, and the occurrence rate can be increased up to about 40 times as much as the mode to lower anode potential only during exposure in this range. (Wakatsuki, Y.)

  5. Counter-cryptanalysis

    NARCIS (Netherlands)

    M.M.J. Stevens (Marc); R. Canetti; J.A. Garay

    2013-01-01

    textabstractWe introduce \\emph{counter-cryptanalysis} as a new paradigm for strengthening weak cryptographic primitives against cryptanalytic attacks. Redesigning a weak primitive to more strongly resist cryptanalytic techniques will unavoidably break backwards compatibility. Instead,

  6. Over-the-counter codeine use in Iceland

    DEFF Research Database (Denmark)

    Almarsdóttir, A B; Grimsson, A

    2000-01-01

    BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using an interru......BACKGROUND: The objective of this study was to test the assumption that liberalizing community pharmacy ownership in Iceland would lead to increased irrational use of over-the-counter pain relievers containing codeine. METHODS: Based on this assumption we built and tested a model using...... an interrupted time series design that contrasts the monthly sales data for over-the-counter pain relievers containing codeine before and after the legislation took effect. RESULTS: The total use of over-the-counter pain relievers containing codeine as well as those containing paracetamol and codeine has risen...... leads to irrational use of over-the-counter medicines is not substantiated in the case of over-the-counter pain relievers containing codeine....

  7. Ideal response function of a 3He proportional counter to thermal neutrons determined by different length counters

    International Nuclear Information System (INIS)

    Takeda, Naoto; Kudo, Katsuhisa; Kobayashi, Katsuhei; Yoshimoto, Takaaki

    2000-01-01

    The relative gas multiplication along the cylindrical axis of three 3 He proportional counters with different length were measured by using a thermal neutron beam at the Kyoto University Reactor and an ideal response function by taking into account the difference of pulse height spectra were measured by different length counters. The three 3 He proportional counters (model type of P4-0806, P4-0806 and P4-0808 manufactured by Reuter-Stokes) prepared for relative gas multiplication measurements had identical structure having cylindrical outer shells of 304 stainless steel except for different sensitive lengths of 10 cm, 15 cm and 20 cm, respectively. All counters were filled with 400 kPa of 3 He gas and 200 kPa of Ar gas. The pulse height distributions were measured by moving the counter in the direction of it's cylindrical axis perpendicular to the thermal neutron beam. The measured pulse heights corresponding to the full energy peaks at various entrance points were normalized to that of the whole counter irradiation. The results as a function of the distance from the bottom edge of the stainless steel cylinder are shown. The total transition region of gas gain corresponded to about 23 %, 15 % and 10 % of each nominal sensitive region corresponding to shot, middle and long counters. The ideal pulse height spectrum (dots) obtained by using proportional counters of 10 cm and 20 cm in nominal sensitive length to thermal neutron beam is shown in the paper in comparison to simulated one which was calculated assuming the constant gain within the sensitive region and zero gas gain outside the sensitive regions. The simulation realized the ideal response function fairly well. (S.Y.)

  8. Radiation in everyday life

    International Nuclear Information System (INIS)

    Wahlstroem, B.

    1994-01-01

    The world is radioactive. Radioactive substances and radiation existed on Earth before the first man was born. Radiation reaches man from the cosmos and is also emitted from radioactive substances in the ground, in construction material, in the food and the air. All people are radioactive, too. For instance, all people have got radioactive Radium and Polonium in their skeleton, radioactive Carbon and Potassium in their muscles and radioactive noble gases and Tritium in their lungs. The radiation emitted by the body can be measured by a very sensitive radiation meter called a Whole Body Counter. This paper is a discussion of natural radioactivity and the increased exposure to radiations released by energy production and medical testing

  9. Aerogel Cerenkov counters at DESY

    International Nuclear Information System (INIS)

    Poelz, G.

    1984-11-01

    In high energy physics it is common to identify a charged particle and its kinematical parameters by the measurement of its momentum and its velocity. Cerenkov detectors have developed into a standard tool because they operate in the γ = (1-β 2 )sup(-1/2) range from about 1 to 100 which is not easily accessible by other devices. Pions, kaons and protons in present high energy experiments reach energies of several GeV. Threshold Cerenkov detectors for these particles need indices of refraction below 1.1 which are often produced with gases under high pressure. The design for chambers operating in this region was drasticly simplified when porous materials serving as Cerenkov radiators were invented. These chambers complement the time-of-flight counters, which cover the low energy region. Aerogel of silica is up to now the only porous substance with sufficient optical transparency. Its quality has been improved substantially in recent times so that large size detectors can be constructed. (orig.)

  10. Basic Research Needs for Countering Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Stevens, W.; Michalske, T.; Trewhella, J.; Makowski, L.; Swanson, B.; Colson, S.; Hazen, T.; Roberto, F.; Franz, D.; Resnick, G.; Jacobson, S.; Valdez, J.; Gourley, P.; Tadros, M.; Sigman, M.; Sailor, M.; Ramsey, M.; Smith, B.; Shea, K.; Hrbek, J.; Rodacy, P.; Tevault, D.; Edelstein, N.; Beitz, J.; Burns, C.; Choppin, G.; Clark, S.; Dietz, M.; Rogers, R.; Traina, S.; Baldwin, D.; Thurnauer, M.; Hall, G.; Newman, L.; Miller, D.; Kung, H.; Parkin, D.; Shuh, D.; Shaw, H.; Terminello, L.; Meisel, D.; Blake, D.; Buchanan, M.; Roberto, J.; Colson, S.; Carling, R.; Samara, G.; Sasaki, D.; Pianetta, P.; Faison, B.; Thomassen, D.; Fryberger, T.; Kiernan, G.; Kreisler, M.; Morgan, L.; Hicks, J.; Dehmer, J.; Kerr, L.; Smith, B.; Mays, J.; Clark, S.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  11. Research on internal dosimetry for some of gamma emitting nuclides for radiation workers by direct method (in-vivo) with using a chair-type whole-body counter

    International Nuclear Information System (INIS)

    Nguyen Van Hung; Pham Hung Thai

    2003-01-01

    This research objective is to establish a chair-type whole-body counter with using NaI(Ti) detector in large sizes and whole-body standard phantoms as well as to apply the computational program of LUDEP 2.0. Steel holder with a lead collimator, two whole-body standard phantoms in Vietnamese adults (one for male and another for female) by plastic material, electronic blocks of ADC and MCD (8K), MCA program for measuring gamma spectrum by VB6 language in Windows are established and made. In addition, applied research for the program of LUDEP 2.0 in order to calculate and evaluated internal doses for radiation workers is carried out. (author)

  12. A fast photo-counter with multi-level buffers

    International Nuclear Information System (INIS)

    Peng Hu; Zhou Peiling; Yao Kun; Guo Guangcan

    1992-01-01

    Digital Photon Correlator (DPC) is composed of a Photo-counter and a data processing unit. The performance of Photo-counter in data acquisition system has a direct influence on data processing. The Photo-counter with fast carry designed here has multi-level buffers. Photon pulses can be correctly and dynamically recorded by the Photo-counter and processed by a single chip computer

  13. Counter-responses as organizers in adolescent analysis and therapy.

    Science.gov (United States)

    Richmond, M Barrie

    2004-01-01

    The author introduces Counter-response as a phenomological term to replace theory-burdened terms like counter-transference, counter-identification, and counter-resistance. He discusses the analyst's use of self (drawing on the comparison with Winnicott's use of the object) in processing the expectable destabilizing counter-reactions that occur in working therapeutically with disturbed adolescents and their parents. Further; he discusses the counter-reaction to the patient's narrative, acting-out, and how re-enactments can serve as an organizer for understanding the patient's inner life when the analyst formulates his/her counter-response. Emphasis is placed on the therapist forming his or her own narrative with the adolescent that takes into account the evoked counter-reaction. For this purpose, the author recommends the use of a combined counter-response and metaphor-orienting perspective to acknowledge and work with the denial, illusions, reversal of perspective, and catastrophic anxieties experienced with these adolescents. The counter-response perspective permits the emergence of the disturbed adolescent's novel narrative; however, since these experiences can be destabilizing or disruptive, the author also recommends the use of a personal metaphor to anticipate the reluctance to examining, processing, and formulating the analyst's dysphoric counter-reaction. With the use of the counter-response, the analyst's therapeutic ideal is to achieve a more optimal balance between using accepted narrative theories and exploring novel enactment experiences. His swimming metaphor stratagem is designed to keep the analyst in these difficult encounters.

  14. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  15. High-speed parallel counter

    International Nuclear Information System (INIS)

    Gus'kov, B.N.; Kalinnikov, V.A.; Krastev, V.R.; Maksimov, A.N.; Nikityuk, N.M.

    1985-01-01

    This paper describes a high-speed parallel counter that contains 31 inputs and 15 outputs and is implemented by integrated circuits of series 500. The counter is designed for fast sampling of events according to the number of particles that pass simultaneously through the hodoscopic plane of the detector. The minimum delay of the output signals relative to the input is 43 nsec. The duration of the output signals can be varied from 75 to 120 nsec

  16. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  17. Assessing a new gene expression analysis technique for radiation biodosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Grainne; Kabacik, Sylwia; Finnon, Paul; Paillier, Francois; Bouffler, Simon [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Badie, Christophe, E-mail: christophe.badie@hpa.org.uk [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom)

    2011-09-15

    The response to any radiation accident or incident involving actual or potential ionising radiation exposure requires accurate and rapid assessment of the doses received by individuals. The techniques available today for biodosimetry purposes are not fully adapted to rapid high-throughput measurements of exposures in large numbers of individuals. A recently emerging technique is based on gene expression analysis, as there are a number of genes which are radiation responsive in a dose-dependent manner. The present work aimed to assess a new technique which allows the detection of the level of expression of up to 800 genes without need of enzymatic reactions. In order to do so, human peripheral blood was exposed ex vivo to a range of x-ray doses from 5 mGy to 4 Gy of x-rays and the transcriptional expression of five radiation-responsive genes PHPT1, PUMA, CCNG1, DDB2 and MDM2 was studied by both the nCounter Digital Analyzer and Multiplex Quantitative Real-Time Polymerase Chain Reaction (MQRT-PCR) as the benchmark technology. Results from both techniques showed good correlation for all genes with R{sup 2} values ranging between 0.8160 and 0.9754. The reproducibility of the nCounter Digital Analyzer was also assessed in independent biological replicates and proved to be good. Although the slopes of the correlation of results obtained by the techniques suggest that MQRT-PCR is more sensitive than the nCounter Digital Analyzer, the nCounter Digital Analyzer provides sensitive and reliable data on modifications in gene expression in human blood exposed to radiation without enzymatic amplification of RNA prior to analysis.

  18. The 'miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Budagov, Yu.; Bellettini, G.

    2002-01-01

    Muon detection is fundamental to many of the interesting analyses at CDF II. For more efficient muon registration in Run II it was decided to increase geometrical coverage. The so-called 'miniskirt' counters are part of this upgrade. The original design parameters of the 'miniskirt' and mixed 'miniskirt' scintillation counters for the CDF Muon System are presented. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of mixed 'miniskirt' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns

  19. Intercomparison of radiation protection instruments based on microdosimetric principles

    International Nuclear Information System (INIS)

    Dietze, G.; Guldbakke, S.; Kluge, H.; Schmitz, T.

    1986-11-01

    Dosemeters based on low-pressure tissue-equivalent proportional counters were developed for the application in radiation protection area monitoring by several groups in Europe. Five different prototypes have been intercompared in a 60 Co photon field, in monoenergetic neutron fields with various energies between 73 keV and 5 MeV and in three neutron fields at a 252 Cf source moderated by a D 2 O sphere. This report describes the radiation fields, the measuring devices and first results of the intercomparison. Additional measurements with a system used in microdosimetry and with a conventional dose equivalent rate meter for neutrons (Rem Counter) were also described. (orig.) [de

  20. Proceedings of the NATO Advanced Research Workshop on Countering Nuclear and Radiological Terrorism

    International Nuclear Information System (INIS)

    Apikyan, S.; Diamond, D.

    2006-01-01

    The objective of this workshop was to identify connections between technology needs and the underlying science and technology, and to establish research strategies that will advanced our ability to counter this form of terrorism. The objectives were met by bringing together international experts familiar with the relevant technologies and policies at a four-day workshop that was held at the Regional Advanced Science and Technology Center (ASTEC), Yerevan, Armenia during October 2005. The many topics covered included: radiation detector development, risk assessment and decision making, decontamination techniques, structural materials resistance to conventional explosives, vulnerability and physical protection of nuclear facilities, security of radiation sources, response to radiological dispersion devices, relevant international and national laws, and non-proliferation

  1. Measurement of radiation damage on an optical reflector

    International Nuclear Information System (INIS)

    Peng, K.C.; Sahu, S.K.; Huang, H.C.; Ueno, K.; Chang, Y.H.; Wang, C.H.; Hou, W.S.

    1997-01-01

    We measured the radiation damage on an optical white fluorocarbon reflector called Goretex, which is to be used for aerogel threshold counters and crystal calorimeters of the BELLE detector of the KEK B-factory. Reflectance of the Goretex surface was monitored to see any effect of the radiation damage. Maximum equivalent dose was 8.6 Mrad. No radiation damage is observed within measurement errors. (orig.)

  2. Nuclear radiation detectors

    International Nuclear Information System (INIS)

    Kapoor, S.S.; Ramamurthy, V.S.

    1986-01-01

    The present monograph is intended to treat the commonly used detectors in the field of nuclear physics covering important developments of the recent years. After a general introduction, a brief account of interaction of radiation with matter relevant to the processes in radiation detection is given in Chapter II. In addition to the ionization chamber, proportional counters and Geiger Mueller counters, several gas-filled detectors of advanced design such as those recently developed for heavy ion physics and other types of studies have been covered in Chapter III. Semiconductor detectors are dealt with in Chapter IV. The scintillation detectors which function by sensing the photons emitted by the luminescence process during the interaction of the impinging radiation with the scintillation detector medium are described in Chapter V. The topic of neutron detectors is covered in Chapter VI, as in this case the emphasis is more on the method of neutron detection rather than on detector type. Electronic instrumentation related to signal pulse processing dealt with in Chapter VII. The track etch detectors based on the visualization of the track of the impinging charge particle have also been briefly covered in the last chapter. The scope of this monograph is confined to detectors commonly used in low and medium energy nuclear physics research and applications of nuclear techniques. The monograph is intended for post-graduate students and those beginning to work with the radiation detectors. (author)

  3. Counter-diabatic driving for Dirac dynamics

    Science.gov (United States)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  4. Counter traction makes endoscopic submucosal dissection easier.

    Science.gov (United States)

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  5. Radiation and Health: A Workshop for Science Educators

    Science.gov (United States)

    Krieger, Kenneth

    2010-03-01

    This workshop covers nuclear science and technology topics suitable for science teachers to use in grade 4-12 classes. Subjects included are Fundamentals of Radiation, Exposure to natural and man- made Radiation, Cellular Biology and Radiation Effects, Radioactive Waste Management, Health Physics and Radiation Physics, and Career possibilities in Nuclear Technology. Schools of participants will receive a working Geiger Counter. Workshop presenter is a TEA-approved CPE Provider. Limited to 20 participants - 3 hours - Cost 2.00

  6. An efficient anticoincidence counter

    CERN Multimedia

    1977-01-01

    This scintillation counter (about 25 cm diameter) was prepared at CERN for an experiment at the Saclay 600 MeV electron linac studying molecular processes originated in liquid hydrogen by muons. The counter is meant to surround the target and detect charged particles emerging from the hydrogen. The experiment was a CERN-Saclay collaboration which used the linac so as to take advantage of the time structure of the electron beam(see CERN Courier Sep 1977 and J. Bardin et al. Phys. Lett. B104 (1981) 320)

  7. COUNTER-PUNISHMENT, COMMUNICATION AND COOPERATION AMONG PARTNERS

    Directory of Open Access Journals (Sweden)

    Giulia eAndrighetto

    2016-04-01

    Full Text Available We study how communication affects cooperation in an experimental public goods environment with punishment and counter-punishment opportunities. Participants interacted over thirty rounds in fixed groups with fixed identifiers that allowed them to trace other group members’ behavior over time. The two dimensions of communication we study are asking for a specific contribution level and having to express oneself when choosing to counter-punish. We conduct four experimental treatments, all involving a contribution stage, a punishment stage and a counter-punishment stage in each round. In the first treatment communication is not possible at any of the stages. The second treatment allows participants to ask for a contribution level at the punishment stage and in the third treatment participants are required to send a message if they decide to counter-punishment. The fourth combines the two communication channels of the second and third treatments. We find that the three treatments involving communication at any of the two relevant stages lead to significantly higher contributions than the baseline treatment. We find no difference between the three treatments with communication. We also relate our results to previous results from treatments without counter-punishment opportunities and do not find that the presence of counter-punishment leads to lower cooperation level. The overall pattern of results shows that given fixed identifiers the key factor is the presence of communication. Whenever communication is possible contributions and earnings are higher than when it is not, regardless of counter-punishment opportunities.

  8. Miniature Active Space Radiation Dosimeter, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Space Micro will extend our Phase I R&D to develop a family of miniature, active space radiation dosimeters/particle counters, with a focus on biological/manned...

  9. Consumer Preferences for High Welfare Meat in Germany: Self-service Counter or Service Counter?

    Directory of Open Access Journals (Sweden)

    Ramona Weinrich

    2015-01-01

    Full Text Available Many people view animal welfare standards in the agricultural industry as critical and some consumers would prefer to buy high welfare meat. In order to successfully introduce high welfare meat products onto the market, some important marketing decisions must be made. Due to limited shelf space in retail outlets, niche products like high welfare meat cannot be placed both at the self-service counter and at the service counter. In order to analyze where to place it best an online survey of 642 German consumers was conducted. By means of factor and cluster analyses, consumers’ animal welfare attitudes and their preference for a point of purchase were combined. The different target groups were joint using cross tabulation analysis. The results reveal that consumers in the target group show a more positive attitude to the service counter.

  10. 21 CFR 866.2170 - Automated colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2170 Automated colony counter. (a) Identification. An automated colony counter is a mechanical device intended for medical...

  11. Development of photocathodes for gas counters

    International Nuclear Information System (INIS)

    Chalot, J.F.

    1982-03-01

    A lot of ways of physics needs the development of high sensibility imaging devices with large sensitive surface. The problems brought by the building of such devices may be solved by the use of gaz counters. But we must sensitize these counters to low energy photons ( [fr

  12. Geometric covers, graph orientations, counter games

    DEFF Research Database (Denmark)

    Berglin, Edvin

    -directed graph is dynamic (can be altered by some outside actor), some orientations may need to be reversed in order to maintain the low out-degree. We present a new algorithm that is simpler than earlier work, yet matches or outperforms the efficiency of these results with very few exceptions. Counter games...... example is Line Cover, also known as Point-Line Cover, where a set of points in a geometric space are to be covered by placing a restricted number of lines. We present new FPT algorithms for the sub-family Curve Cover (which includes Line Cover), as well as for Hyperplane Cover restricted to R 3 (i...... are a type of abstract game played over a set of counters holding values, and these values may be moved between counters according to some set of rules. Typically they are played between two players: the adversary who tries to concentrate the greatest value possible in a single counter, and the benevolent...

  13. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  14. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H

    2015-09-23

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  15. On generating counter-rotating streamwise vortices

    KAUST Repository

    Winoto, S H; Mitsudharmadi, Hatsari; Budiman, A C; Hasheminejad, S M; Nadesan, T; Tandiono; Low, H T; Lee, T S

    2015-01-01

    Counter-rotating streamwise vortices are known to enhance the heat transfer rate from a surface and also to improve the aerodynamic performance of an aerofoil. In this paper, some methods to generate such counter-rotating vortices using different methods or physical conditions will be briefly considered and discussed.

  16. Development of DIRC counters for the PANDA experiment at FAIR

    International Nuclear Information System (INIS)

    Seitz, B.; Bettoni, D.; Branford, D.; Britting, A.; Carassiti, V.; Cecchi, A.; Cowie, E.; Dodokhof, V.Kh.; Dueren, M.; Eyrich, W.; Foehl, K.; Hayrapetyan, A.; Hill, G.; Hoek, M.; Hohler, R.; Kaiser, R.; Keri, T.; Lehmann, A.; Lehmann, D.; Marton, J.

    2011-01-01

    The PANDA experiment at the planned FAIR facility at GSI, Darmstadt, aims at measuring hadronic final states with unprecedented precision and luminosity. Superior particle identification of charged and neutral particles is mandatory to fulfil PANDA's physics aims. DIRC (Detection of Internally Reflected Cherenkov light) counters are foreseen for charged particle identification. A barrel DIRC will cover the central region while a disc DIRC will provide particle identification in the forward region. Three DIRC concepts differing in the radiator geometry and method for dispersion correction are studied. The barrel DIRC uses a novel imaging system and aims at exploiting a 3D reconstruction to mitigate dispersion effects. Two concepts are investigated for the forward disc DIRC. One concept employs passive dispersion correction and focussing light guides for image reconstruction. Alternatively, time-of-propagation measurements and a wave-length dependent photon detection system are investigated. The three detector designs share common developments such as investigating radiator properties and photon detection systems, and use the same test beam facilities.

  17. Variation of Natural Gamma Radiation in Isparta

    International Nuclear Information System (INIS)

    Akkurt, I.

    2004-01-01

    There is always a radiation in the earth, and its level is generated primarily by galactic cosmic rays (GCR), consisting of energetic nuclei of all naturally occurring elements, interacting with atmospheric constituents, through atomic and nuclear collisions. The other sources of natural radiations are global average background radiation from terrestrial sources such as soils, rocks ete. Background radiation levels in the atmosphere vary in intensity with latitude, altitude and phase of the solar cycle. Variation of natural radiation as a function of altitude, geological structure etc has been investigated. The measurements were performed using portable radiation counter which connected to NaI(Tl) probe

  18. Counter Traction Makes Endoscopic Submucosal Dissection Easier

    OpenAIRE

    Oyama, Tsuneo

    2012-01-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable co...

  19. Israel's Counter-Terrorism Strategy and its Effectiveness

    National Research Council Canada - National Science Library

    Smith, Jerry D

    2005-01-01

    This thesis analyzes Israeli counter-terrorism strategy and its effectiveness. Because of ongoing suicide attacks from Palestinian and other terrorist organizations, Israel will continue to have an aggressive counter-terrorism strategy...

  20. Research on environment monitoring of radiation emergency

    CERN Document Server

    Ito, Y; Otani, N

    2003-01-01

    In a case of a nuclear accident at nuclear facilities, strong radiation such as g-rays and neutrons might radiate at a burst in the initial stage. For the establishment of dose estimation system for such accidents, the experiments were done using the He sup + sup 2 beam accelerated by Tandem in the W-MAST. The following results were obtained. 1) Neutron measurements using a rem counter yielded that dose equivalent was about 9.4 mSv/h at a position 100 cm from the Be target when the beam current of 15 MeV He sup 2 sup + was 0.8 mu A. Neutron measurement by means of Au and In foil activation method and by use of TLD element revealed that dose equivalents were to be 16-27 mu Sv/h for thermal neutron, and 30-41 mu Sv/h for sub-fast neutron (20 keV). Therefore, it was concluded that neutron field was mainly composed by fast neutron. 2) Linearity of the rem-counter out put vs neutron flux was valid under the condition that the count rate of the rem-counter was less than 10 kcps. 3) Computer simulation using NRESP c...

  1. Position sensitive proportional counters as focal plane detectors

    International Nuclear Information System (INIS)

    Ford, J.L.C. Jr.

    1979-01-01

    The rise time and charge division techniques for position decoding with RC-line proportional counters are reviewed. The advantages that these detectors offer as focal plane counters for nuclear spectroscopy performed with magnetic spectrographs are discussed. The theory of operation of proportional counters as position sensing devices is summarized, as well as practical aspects affecting their application. Factors limiting the position and energy resolutions obtainable with a focal plane proportional counter are evaluated and measured position and energy loss values are presented for comparison. Detector systems capable of the multiparameter measurements required for particle identification, background suppression and ray-tracing are described in order to illustrate the wide applicability of proportional counters within complex focal plane systems. Examples of the use of these counters other than with magnetic spectrographs are given in order to demonstrate their usefulness in not only nuclear physics but also in fields such as solid state physics, biology, and medicine. The influence of the new focal plane detector systems on future magnetic spectrograph designs is discussed. (Auth.)

  2. CORNELL: CLEO's counters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Particle identification by measuring ionization is complicated by the fact that the energy lost to ionization in passing through matter has large fluctuations, first calculated by Landau. These large fluctuations imply that many measurements must be made in order to determine the most probable ionization value that is characteristic of the particle type. The JADE chamber at PETRA and the TPC chamber at PEP measure both the ionization and the momenta of tracks in the same device. In the CLEO experiment at Cornell's CESR ring, ionization is measured in dedicated energy loss counters contained in each of the eight octants surrounding the drift chamber and superconducting coil. The last of these were installed in the summer of 1981, replacing Cherenkov counters that were used while the energy loss counters were being developed and built

  3. Channel coincidence counter: version 1

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1980-06-01

    A thermal neutron coincidence counter has been designed for the assay of fast critical assembly fuel drawers and plutonium-bearing fuel rods. The principal feature of the detector is a 7-cm by 7-cm by 97-cm detector channel, which provides a uniform neutron detection efficiency of 16% along the central 40 cm of the channel. The electronics system is identical to that used for the High-Level Neutron Coincidence Counter

  4. Strategies for Discovery of Small Molecule Radiation Protectors and Radiation Mitigators

    Energy Technology Data Exchange (ETDEWEB)

    Greenberger, Joel S.; Clump, David [Radiation Oncology Department, University of Pittsburgh Cancer Institute, Pittsburgh, PA (United States); Kagan, Valerian [Environmental and Occupational Health Department, University of Pittsburgh, Pittsburgh, PA (United States); Bayir, Hülya [Critical Care Medicine Department, University of Pittsburgh Medical Center, Pittsburgh, PA (United States); Lazo, John S. [Pharmacology Department, University of Virginia, Charlottesville, VA (United States); Wipf, Peter [Department of Chemistry, Accelerated Chemical Discovery Center, University of Pittsburgh, Pittsburgh, PA (United States); Li, Song; Gao, Xiang [Pharmaceutical Science Department, University of Pittsburgh, Pittsburgh, PA (United States); Epperly, Michael W., E-mail: greenbergerjs@upmc.edu [Radiation Oncology Department, University of Pittsburgh Cancer Institute, Pittsburgh, PA (United States)

    2012-01-13

    Mitochondrial targeted radiation damage protectors (delivered prior to irradiation) and mitigators (delivered after irradiation, but before the appearance of symptoms associated with radiation syndrome) have been a recent focus in drug discovery for (1) normal tissue radiation protection during fractionated radiotherapy, and (2) radiation terrorism counter measures. Several categories of such molecules have been discovered: nitroxide-linked hybrid molecules, including GS-nitroxide, GS-nitric oxide synthase inhibitors, p53/mdm2/mdm4 inhibitors, and pharmaceutical agents including inhibitors of the phosphoinositide-3-kinase pathway and the anti-seizure medicine, carbamazepine. Evaluation of potential new radiation dose modifying molecules to protect normal tissue includes: clonogenic radiation survival curves, assays for apoptosis and DNA repair, and irradiation-induced depletion of antioxidant stores. Studies of organ specific radioprotection and in total body irradiation-induced hematopoietic syndrome in the mouse model for protection/mitigation facilitate rational means by which to move candidate small molecule drugs along the drug discovery pipeline into clinical development.

  5. The pin detector - a simple, robust, cheap and effective nuclear radiation detector

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1984-01-01

    The development of a series of radiation detectors bases on the point anode is reported. Using readily available preformed pins from a variety of electrical connectors as the anodes, a family of devices has been created with useful properties as X-ray detectors, radiation monitors and internal beta counters. A wide variety of gas fillings can be used, argon/CH 4 premix being the most convenient. The structures are robust and call for no precision alignments so keeping costs down. Performance of the devices in respect of sensitivity and pulse height resolution is comparable to that of conventional wire counters. (author)

  6. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  7. Cloud Condensation Nuclei Particle Counter (CCN) Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, Janek [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Cloud Condensation Nuclei Counter—CCN (Figure 1) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei [1, 2]. The CCN draws the sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an Optical Particle Counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN-200 differ only in the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.

  8. Efficiency calibration of solid track spark auto counter

    International Nuclear Information System (INIS)

    Wang Mei; Wen Zhongwei; Lin Jufang; Liu Rong; Jiang Li; Lu Xinxin; Zhu Tonghua

    2008-01-01

    The factors influencing detection efficiency of solid track spark auto counter were analyzed, and the best etch condition and parameters of charge were also reconfirmed. With small plate fission ionization chamber, the efficiency of solid track spark auto counter at various experiment assemblies was re-calibrated. The efficiency of solid track spark auto counter at various experimental conditions was obtained. (authors)

  9. Generalization of the development of liquid-sparkling counter

    International Nuclear Information System (INIS)

    Bian Zhengzhu; Zhang Jue; Zhang Jinwei

    2006-01-01

    This paper includes five parts. It not only reviews the development history of liquid-sparkling counter but refers that the appearance of coincident circuit is its milestone. The paper summarizes the resembled hard ware and soft ware and soft ware of liquid-sparkling counter of indoor and overseas, and prospects the development of liquid-sparkling counter in our country. (authors)

  10. Control method and device for automatic drift stabilization in radiation detection

    International Nuclear Information System (INIS)

    Berthold, F.; Kubisiak, H.

    1979-01-01

    In the automatic control circuit individual electron peaks in the detectors, e.g. NaI crystals or proportional counters, are used. These peaks exhibit no drift dependence; they may be produced in the detectors in different ways. The control circuit may be applied in nuclear radiation measurement techniques, photometry, gamma cameras and for measuring the X-ray fine structure with proportional counters. (DG) [de

  11. Performance tests of a full scale prototype of the Belle II TOP counter with cosmic muons and 2.1 GeV/c positron beam

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Tomokatsu

    2014-12-01

    A time-of-propagation detector named TOP is a hadronic particle identification system for the Belle II experiment. We have produced a full scale prototype of the Belle II TOP counter and tested with cosmic muons at KEK and the 2.1 GeV/c positrons at SPring-8 LEPS beamline. The procedures for the quartz acceptance test and assembly worked well and the first quartz radiator was successfully fabricated. The obtained test data shows good agreement with Monte Carlo expectation. - Highlights: • We have successfully produced a full scale prototype of the Belle II TOP counter. • The prototype counter has been tested at KEK and SPring-8 LEPS beamline. • The obtained test data shows good agreement with Monte Carlo expectation.

  12. Advertising health: the case for counter-ads.

    Science.gov (United States)

    Dorfman, L; Wallack, L

    1993-01-01

    Public service advertisements have been used by many in hopes of "selling" good health behaviors. But selling good behavior--even if it could be done more effectively--is not the best goal for using mass media to prevent health problems. Personal behavior is only part of what determines health status. Social conditions and the physical environment are important determinants of health that are usually ignored by health promotion advertising. Public service advertising may be doing more harm than good if it is diverting attention from more effective socially based health promotion strategies. Counter-ads are one communications strategy that could be used to promote a broader responsibility for rectifying health problems. In the tradition of advocacy advertising directly promoting policy rather than products, counter-ads promote views consistent with a public health perspective. Counter-ads set the agenda for health issues, conferring status on policy-oriented strategies for addressing health problems. The primary purpose of counter-ads is to challenge the dominant view that public health problems reflect personal health habits. They are controversial because they place health issues in a social and political context. Advertising strategies for health promotion range over a spectrum from individually oriented public service advertising to socially oriented counter-advertising. The recent anti-tobacco campaign from the California Department of Health Services represents advertisements across the spectrum. Counter-ads that focus on a politically controversial definition for health problems are an appropriate and necessary alternative to public service advertising. PMID:8265756

  13. Monte Carlo Studies of a Novel LiF Radiator for RICH Detectors

    OpenAIRE

    Efimov, A.; Artuso, M.; Gao, Min; Mountain, R.; Muheim, F.; Mukhin, Y.; Playfer, S.

    1995-01-01

    We show that a multifaceted LiF radiator produces more Cherenkov light and has better resolution per photon than a flat radiator slab when used in a ring imaging Cherenkov counter. Such a system is being considered for the CLEO III upgrade.

  14. Transfer of 137Cs in two farm ecosystems. Calculated effects of counter-measures following a postulated fallout land contamination

    International Nuclear Information System (INIS)

    Andersson, I.; Loensjoe, H.

    1988-01-01

    Studies were performed on two farms, B and R, in southern Sweden to calculate the consequences after a postulated nuclear reactor accident involving contamination of land by 137Cs (1 MBq per m2). The activity transfer to crops and animal products during the sixth year after the fallout was calculated for situations without and with counter-measures taken. The effects of counter-measures, fertilizing with potassium, deep-ploughing and also modified crop and animal production, were supposed to have reached all parts of the agricultural systems. Steady state conditions were assumed to be prevailing in both situations. Calculations based on the present (in 1985) production on the farms and compiled for the situation without any counter-measures taken, indicate the root uptake of 137Cs in the crops during the year to be 53 MBq (B) and 280 MBq (R) corresponding to 1.0 and 1.6 MBq per hectare, respectively. Through the crops 46 MBq (B) and 187 MBq (R) are ingested by the animals. On the basis of the mean daily activity intake per animal, a total of about 5 MBq on each farm is calculated to be transferred to the animal products (milk and meat). Related to the land area this corresponds to 0.09 and 0.03 MBq per hectare on B and R respectively. The mean internal radiation dose during the year per person on the farms through home-produced food is calculated to be 0.1 mSv (B) and 0.2 mSv (R), and the mean external radiation dose to people working on the farms to be the same as that from the natural background. Calculations for the year in the situation with counter-measures taken indicate that the transferred activity of 137Cs to the crops per hectare is reduced by factors of 10 (B) and 3 (R). The corresponding transfer to animal products is by factors of 23 or 45 (B) and 3 (R), although in the latter case the size of animal production is considerably increased. The external and possibly also the internal radiation doses to people on both farms will be reduced

  15. Experimental validation of GADRAS's coupled neutron-photon inverse radiation transport solver

    International Nuclear Information System (INIS)

    Mattingly, John K.; Mitchell, Dean James; Harding, Lee T.

    2010-01-01

    Sandia National Laboratories has developed an inverse radiation transport solver that applies nonlinear regression to coupled neutron-photon deterministic transport models. The inverse solver uses nonlinear regression to fit a radiation transport model to gamma spectrometry and neutron multiplicity counting measurements. The subject of this paper is the experimental validation of that solver. This paper describes a series of experiments conducted with a 4.5 kg sphere of α-phase, weapons-grade plutonium. The source was measured bare and reflected by high-density polyethylene (HDPE) spherical shells with total thicknesses between 1.27 and 15.24 cm. Neutron and photon emissions from the source were measured using three instruments: a gross neutron counter, a portable neutron multiplicity counter, and a high-resolution gamma spectrometer. These measurements were used as input to the inverse radiation transport solver to evaluate the solver's ability to correctly infer the configuration of the source from its measured radiation signatures.

  16. Theory for beam-plasma millimeter-wave radiation source experiments

    International Nuclear Information System (INIS)

    Rosenberg, M.; Krall, N.A.

    1989-01-01

    This paper reports on theoretical studies for millimeter-wave plasma source experiments. In the device, millimeter-wave radiation is generated in a plasma-filled waveguide driven by counter-streaming electron beams. The beams excite electron plasma waves which couple to produce radiation at twice the plasma frequency. Physics topics relevant to the high electron beam current regime are discussed

  17. Use of the helium-3 proportional counter for neutron spectrometry

    International Nuclear Information System (INIS)

    Vialettes, H.; Le Thanh, P.

    1967-01-01

    Up to now, two methods have been mainly used for neutron spectrometry near nuclear installations: - photographic emulsion spectrometry - the so-called, 'multisphere' technique spectrometry. The first method, which is fairly difficult to apply, has a threshold energy of about 500 keV; this is a big disadvantage for an apparatus which has to be used for spectrometry around nuclear installations where the neutron radiation is very much degraded energetically. The second method does not suffer from this disadvantage but the results which it yields are only approximate. In order to extend the energy range of the neutron spectra studied with sufficient accuracy the use of a helium-3 proportional counter has been considered. This report presents the principles of operation of the helium-3 spectrometer, and the calculation methods which make it possible to take into account the two main effects tending to deform the spectra obtained: - energy absorption by the walls of the counter, - energy loss of the incident neutrons due to elastic collisions with helium-3 nuclei. As an example of the application, the shape of the neutron spectrum emitted by a polonium-lithium source is given; the results obtained are in excellent agreement with theoretical predictions. (authors) [fr

  18. The RM-5000 system for radiation monitoring

    International Nuclear Information System (INIS)

    1997-01-01

    Eight models of radiation monitors can be assembled from independent modules for the agricultural firms, customs house, boundary transitions, for the control of transport and passenger flows and for prevention of the non-authorized moving of radioactive and fissionable materials. Two modules are a basis of the system - gamma radiation detector on the basis of plastic scintillator and neutrons detector on the basis of the proportional 3 He counters

  19. Irradiation of the Bulgarian population with secondary cosmic radiation

    International Nuclear Information System (INIS)

    Vasilev, G.

    1983-01-01

    The radiation of the Bulgarian population was estimated, the former being due to secondary space radiation. A method of calculation was applied using the values for dose powers at different heights, proposed by the Research Committee on Atomic Radiation Action (UNO, 1976). Parallelly with that comparative measurements were taken using counters for space radiation VA-Z-232. The stay of the population in different type buildings was taken into account. The mean annual dose of radiation of the Bulgarian population from the secondary space radiation is 245μGy, and the collective effective equivalent dose is 2, 2.10 3 hum sv. (authors)

  20. Counter - Drug: Mandate for the Army.

    Science.gov (United States)

    1991-03-01

    this comprehensive review will provide a basis for responding to new missions assigned...observations for determining the short-, mid-, and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide...and long-term direction of Army support to the national counter-drug effort. Also, this comprehensive review will provide a basis for responding

  1. Hardware support for software controlled fast multiplexing of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-01-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  2. Count rate effect in proportional counters

    International Nuclear Information System (INIS)

    Bednarek, B.

    1980-01-01

    A new concept is presented explaining changes in spectrometric parameters of proportional counters which occur due to varying count rate. The basic feature of this concept is that the gas gain of the counter remains constant in a wide range of count rate and that the decrease in the pulse amplitude and the detorioration of the energy resolution observed are the results of changes in the shape of original current pulses generated in the active volume of the counter. In order to confirm the validity of this statement, measurements of the gas amplification factor have been made in a wide count rate range. It is shown that above a certain critical value the gas gain depends on both the operating voltage and the count rate. (author)

  3. Design of a hybrid gas proportional counter with CdTe guard counters for sup 1 sup 4 C dating system

    CERN Document Server

    Zhang, L; Hinamoto, N; Nakazawa, M; Yoshida, K

    2002-01-01

    Nowadays uniform, low-cost and large-size compound semiconductor detectors are available up to several square centimeters. We are trying to combine this technology with conventional gas detectors to upgrade an anticoincidence type proportional counter, Oeschger-type thin wall counter of 2.2 l, used for a sup 1 sup 4 C dating facility at the University of Tokyo. In order to increase the ratio of the signal to the background for smaller quantity of samples less than 1 g, an effective approach is to minimize the detector volume at higher gas pressure. However, the anticoincidence function suffers from such a small volume. Therefore we designed a new active wall gas counter of 0.13 l counting volume using CdTe compound semiconductor detectors as the wall of the gas proportional counter to perform anticoincidence. Simulation study showed that at noise thresholds less than 70 keV, the wall counters can reject above 99.8% of events arising from outer gamma rays. Measured noise levels of CdTe detectors were smaller t...

  4. Strategies for Discovery of Small Molecule Radiation Protectors and Radiation Mitigators

    Directory of Open Access Journals (Sweden)

    Joel S Greenberger

    2012-01-01

    Full Text Available Mitochondrial targeted radiation damage protectors (delivered prior to irradiation and mitigators (delivered after irradiation, but before the appearance of symptoms associated with radiation syndrome have been a recent focus in drug discovery for 1 normal tissue radiation protection during fractionated radiotherapy, and 2 radiation terrorism counter measures. Several categories of such molecules have been discovered: nitroxide-linked hybrid molecules, including GS-nitroxide, GS-nitric oxide synthase inhibitors, p53/mdm2/mdm4 inhibitors, and pharmaceutical agents including inhibitors of the phosphoinositide-3-kinase pathway and the anti-seizure medicine, carbamazepine. Evaluation of potential new irradiation dose modifying molecules to protect normal tissue includes: clonagenic radiation survival curves; assays for apoptosis and DNA repair, and irradiation-induced depletion of antioxidant stores. Studies of organ specific radioprotection and in total body irradiation-induced hematopoietic syndrome in the mouse model for protection/mitigation facilitate rational means by which to move candidate small molecule drugs along the drug discovery pipeline into clinical development.

  5. Detection of environmental radioactive contamination levels using a liquid-scintillation counter

    International Nuclear Information System (INIS)

    Calisto, W.; Kun, A.; Campos, E.

    1981-01-01

    A high-efficiency LS-100 C liquid scintillation counter was used to detect low levels of environmental activity. Different concentrations of primary scintillator were tested and these established the most suitable values. Work was carried out at the same time to find conditions which would ensure a low background and high efficiency. To reduce the sample volume used, various types of chelating agents were utilized: 8-hydroxyquinoline (oxine), tannic acid, cupferron, dimethylglioxime and beta-naphthol. These were tested at pH levels of 1, 6 and 11. Measurements were performed by means of the Cerenkov effect using substances with differing refraction indices - 26% sodium chloride, water, glycerine, carbon bisulphide, nitrobenzene, benzyl alcohol and toluene. Finally, work was done on comparing spectra obtained by Cerenkov radiation and by 90 Sr and 90 Y beta radiation respectively. Clearly differentiated zones were obtained, thus making it possible to distinguish one isotope from another in an equilibrium solution. (author)

  6. Ultra Low Level Tritium Analysis Method Using a Liquid Scintillation Counter

    Energy Technology Data Exchange (ETDEWEB)

    Noh, S. J.; Kim, H. J.; Kim, H.; Lim, H. J.; Lee, M. W.; Jeong, D. H.; Kim, J. K.; Kang, Y. R. [Dongnam Institute of Radiological and Medical Sciences, Busan (Korea, Republic of); Nam, S. H. [Inje University, Gimhae, (Korea, Republic of)

    2015-05-15

    To evaluate {sup 3}H concentration in the atmosphere more accurately compared to the conventional methods, the author of this paper intended to suggest more improved analytical methods and derived the elements which might occur during analysis or required improvements. The method suggested in this study is able to reduce the uncertainty and errors which may be existent in evaluating the {sup 3}H concentration of environmental sample s and thus will serve as the best solution in the technical and economic point of view. Liquid Scintillation Counter is the most widely used to analyze ultra-low level {sup 3}H by using CPM / DPM Counting Mode using external radiation source and Spectrum Plot Mode using internal radiation source. In CPM / DPM Counting Mode, multiple samples can be measured by single calibration despite its rather higher background whereas Spectrum Plot Mode requires more time and cost to analyze multiple samples despite its reliability to reduce the contribution of other radionuclides.

  7. COUNTER-ROTATION IN RELATIVISTIC MAGNETOHYDRODYNAMIC JETS

    Energy Technology Data Exchange (ETDEWEB)

    Cayatte, V.; Sauty, C. [Laboratoire Univers et Théories, Observatoire de Paris, UMR 8102 du CNRS, Université Paris Diderot, F-92190 Meudon (France); Vlahakis, N.; Tsinganos, K. [Department of Astrophysics, Astronomy and Mechanics, Faculty of Physics, University of Athens, 15784 Zografos, Athens (Greece); Matsakos, T. [Department of Astronomy and Astrophysics, The University of Chicago, Chicago, IL 60637 (United States); Lima, J. J. G., E-mail: veronique.cayatte@obspm.fr [Centro de Astrofísica, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal)

    2014-06-10

    Young stellar object observations suggest that some jets rotate in the opposite direction with respect to their disk. In a recent study, Sauty et al. showed that this does not contradict the magnetocentrifugal mechanism that is believed to launch such outflows. Motion signatures that are transverse to the jet axis, in two opposite directions, have recently been measured in M87. One possible interpretation of this motion is that of counter-rotating knots. Here, we extend our previous analytical derivation of counter-rotation to relativistic jets, demonstrating that counter-rotation can indeed take place under rather general conditions. We show that both the magnetic field and a non-negligible enthalpy are necessary at the origin of counter-rotating outflows, and that the effect is associated with a transfer of energy flux from the matter to the electromagnetic field. This can be realized in three cases: if a decreasing enthalpy causes an increase of the Poynting flux, if the flow decelerates, or if strong gradients of the magnetic field are present. An illustration of the involved mechanism is given by an example of a relativistic magnetohydrodynamic jet simulation.

  8. Prototype of IGZO-TFT preamplifier and analog counter for pixel detector

    International Nuclear Information System (INIS)

    Shimazoe, K.; Koyama, A.; Takahashi, H.; Shindoh, T.; Miyoshi, H.

    2017-01-01

    IGZO-TFT (Indium Galium Zinc Oxide-Thin Film Transistor) is a promising technology for controlling large display areas and large area sensors because of its very low leakage current in the off state and relatively low cost. IGZO has been used as a switching gate for a large area flat-panel detector. The photon counting capability for X-ray medical imaging has been investigated and expected for low-dose exposure and material determination. Here the design and fabrication of a charge sensitive preamplifier and analog counter using IGZO-TFT processes and its performance are reported for the first time to be used for radiation photon counting applications.

  9. Numerical modelling of tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Segur, P.; Colautti, P.

    1995-01-01

    In this paper a survey is given of the various numerical techniques employed to study the transport of ionising particles inside a TEPC. The first part is devoted to the description of the general concept of particle transport calculations. Thereafter, the different methods available to study transport phenomena and energy deposition in the sensitive volume and in counter walls are described. Finally, the basic ionisation mechanisms which may occur in a counter are described, and the non-equilibrium phenomena which play an important role mainly for counters that are to be used in measurements at the nanodosemeter level are studied. (author)

  10. Neutron dosimetry using proportional counters with tissue equivalent walls

    International Nuclear Information System (INIS)

    Kerviller, H. de

    1965-01-01

    The author reminds the calculation method of the neutron absorbed dose in a material and deduce of it the conditions what this material have to fill to be equivalent to biological tissues. Various proportional counters are mode with walls in new tissue equivalent material and filled with various gases. The multiplication factor and neutron energy response of these counters are investigated and compared with those obtained with ethylene lined polyethylene counters. The conditions of working of such proportional counters for neutron dosimetry in energy range 10 -2 to 15 MeV are specified. (author) [fr

  11. Charged particle identification: Cherenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Etkin, A.; Kostoulas, I.; Leith, D.W.G.S.; Thun, R.

    1977-01-01

    A brief summary is given of a study of Cherenkov counters for ISABELLE. The study was certainy not exhaustive and was meant primarily to suggest future detector development. A substantial research effort is needed in order to insure that Cherenkov counters utilizing photoionization are fully exploited

  12. The Banking Counter-Guarantee. Juridical Regime

    Directory of Open Access Journals (Sweden)

    Postolache Rada

    2009-06-01

    Full Text Available Not so much studied by the specialised literature, the banking counter-guarantee may beconfounded with the other types of guarantee which frequently go with the guaranteed obligation –simple guarantee, collateral guarantee, the confirmation of the guarantee. The counter-guarantee may bean independent or accessory obligation, as the case may be, exclusively governed by its text, accordingto the parties’ will. At the same time, it is a complex juridical act, a contract whose contents cannot beset apart from the contracts connected form an “economic” point of view. The counter-guarantee is theresult of the banking practice and is generated by the need to make amends for the flaws generated bythe direct guarantee. The present research is focused on the analysis of the banking practice, normativeacts, jurisprudence and banking juridical literature.

  13. The scintillation counter system at the SAPHIR detector

    International Nuclear Information System (INIS)

    Bour, D.

    1989-10-01

    The scintillation-counters system of the SAPHIR-detector at the stretcher accelerator ELSA in Bonn consists of 64 counters. It supplies a fast hadronic trigger and is utilizised for the particle identification by time of flight measurements. Prototypes of the counters (340x21.25 x 6.0 cm 3 ) had been tested. The contribution to the resolution of the time of flight measurement was measured to σ=125 ps, the effective light velocity to 17.5 ns/cm and the attenuation length of 7.8 m. A pion kaon separation is possible up to a momentum of 1 GeV/c with time of flight measurement. With the first photon-beam at SAPHIR the counters were tested, first triggers were obtained and evaluated. (orig.) [de

  14. Comparative investigation of three dose rate meters for their viability in pulsed radiation fields

    International Nuclear Information System (INIS)

    Gotz, M; Karsch, L; Pawelke, J

    2015-01-01

    Pulsed radiation fields, characterized by microsecond pulse duration and correspondingly high pulse dose rates, are increasingly used in therapeutic, diagnostic and research applications. Yet, dose rate meters which are used to monitor radiation protection areas or to inspect radiation shielding are mostly designed, characterized and tested for continuous fields and show severe deficiencies in highly pulsed fields. Despite general awareness of the problem, knowledge of the specific limitations of individual instruments is very limited, complicating reliable measurements. We present here the results of testing three commercial dose rate meters, the RamION ionization chamber, the LB 1236-H proportional counter and the 6150AD-b scintillation counter, for their response in pulsed radiation fields of varied pulse dose and duration. Of these three the RamION proved reliable, operating in a pulsed radiation field within its specifications, while the other two instruments were only able to measure very limited pulse doses and pulse dose rates reliably. (paper)

  15. Quality control and the multicrystal counter

    International Nuclear Information System (INIS)

    Hart, G.C.; Davis, K.M.

    1983-01-01

    The reliability of multicrystal counters for use in counting large numbers of radioimmunoassay samples is studied. In particular, the dependencies of the outputs from the array of detectors, and hence their degree of matching, on the count rate and volume of the samples being counted are investigated. Quality control procedures are described to assist in the assurance of consistent performance of the counter in the clinical situation. (U.K.)

  16. Pulse formation of gas-filled counter

    International Nuclear Information System (INIS)

    Iwatani, Kazuo; Teshima, Kazunori; Shizuma, Kiyoshi; Hasai, Hiromi

    1991-01-01

    The pulse formation of gas-filled counter has been calculated by simple models for the proportional and self-quenching streamer (SQS) modes. Calculated pulse shapes of counter output have accurately reproduced the observed ones for both modes. As a result, it is shown that the special density distribution of ion pairs in a streamer can be estimated with the rising part of observed pulse shape, using the model. (author)

  17. Vocational education training in environmental health sciences: using ionizing radiation detectors, module 11

    International Nuclear Information System (INIS)

    May, F.C.

    1981-07-01

    In this instructional module, students learn to operate a geiger counter and read a pocket ion chamber dosimeter in demonstrating how radiation levels are affected by distance, shielding, and time. Training Prerequisites: Before beginning this module, students should be, or have been, enrolled in a course on radiation safety or its equivalent at the 2-year technical-school or college level. Upon completion of this module, students will be able to perform the following functions: (1) Name and tell the function of the major components of a geiger counter and check its operation using a sealed check source of low radioactivity. (2) Read a pocket ion chamber dosimeter and recharge the dosimeter using a dosimeter charger. (3) Demonstrate what effects distance, shielding, and time have on radiation levels

  18. HOW THE WAR WAS ‘ONE’: COUNTERING VIOLENT EXTREMISM AND THE SOCIAL DIMENSIONS OF COUNTER-TERRORISM IN CANADA.

    Directory of Open Access Journals (Sweden)

    Tami Amanda Jacoby

    2016-03-01

    Full Text Available The current global “war on terror” highlights a fundamental quandary for all liberal democracies seeking to counter the violent extremism of their own citizens while maintaining civic rights and freedoms. This challenge accompanies a transformation in international conflict from inter-state war and superpower rivalry, to homegrown terrorism, radicalization-to-violence, Internet propaganda, and targeting and recruitment of vulnerable persons. These new threats shift the battlefield, as traditionally defined, to the home front, as extremist violence is nurtured by and perpetrated within public spaces, such as schools, places of religious worship, civil society and the home. Today, violence emanates from within liberal democratic society and its extremist motivations bypass the very institutions that would otherwise support civic rights, freedoms and multiculturalism. As such, attempts to counter extremist violence must appeal to the political, social, cultural, religious and familial aspects of human behavior alongside a parallel shift in efforts to keep citizens safe within their own social spaces. In recent years, Canada has been introduced to home grown and lone individual terrorism with the cases of attack against armed forces personnel in Saint-Jean-sur-Richelieu and Ottawa in 2014. This article identifies the social dimensions of counter-terrorism in the Canadian context, a propitious case by which to evaluate different approaches to countering violent extremism. Canadian initiatives - simultaneously proliferating and in their infancy – raise a host of questions about counter-terrorism in liberal democratic countries. For example, why do individuals radicalize-to-violence in rights-based and multicultural societies? How and when can the liberal democratic state best temper the radicalization process in ways that are effective and procedurally just? What state-society balance works best to counter radicalized viewpoints? Who are the

  19. Design of a novel quantum reversible ternary up-counter

    Science.gov (United States)

    Houshmand, Pouran; Haghparast, Majid

    2015-08-01

    Reversible logic has been recently considered as an interesting and important issue in designing combinational and sequential circuits. The combination of reversible logic and multi-valued logic can improve power dissipation, time and space utilization rate of designed circuits. Only few works have been reported about sequential reversible circuits and almost there are no paper exhibited about quantum ternary reversible counter. In this paper, first we designed 2-qutrit and 3-qutrit quantum reversible ternary up-counters using quantum ternary reversible T-flip-flop and quantum reversible ternary gates. Then we proposed generalized quantum reversible ternary n-qutrit up-counter. We also introduced a new approach for designing any type of n-qutrit ternary and reversible counter. According to the results, we can conclude that applying second approach quantum reversible ternary up-counter is better than the others.

  20. Reduction of degraded events in miniaturized proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Plaga, R.; Kirsten, T. (Max Planck Inst. fuer Kernphysik, Heidelberg (Germany))

    1991-11-15

    A method to reduce the number of degraded events in miniaturized proportional counters is described. A shaping of the outer cathode leads to a more uniform gas gain along the counter axis. The method is useful in situations in which the total number of decay events is very low. The effects leading to degraded events are studied theoretically and experimentally. The usefulness of the method is demonstrated by using it for the proportional counter of the GALLEX solar neutrino experiment. (orig.).

  1. Fluorescent L-radiation and the. gamma. -radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Riou, M

    1949-02-21

    Irene Curie, Compt. rend. 227, 1225(1948), has shown that the ..gamma..-radiation of ionium is accompanied by a soft radiation that can be identified with the fluorescent L-lines of radium. The present author submitted these radiations to a further study, using as a source a ionium--thorium mixture, (100 mg of hydrate), containing 9% ionium. The Geiger--Mueller counters had 5 mg/cm/sup 2/ aluminum ends and were filled with alcohol + xenon at 10-21 cm Hg. The absorption curves in Cu, Mo, and Ag showed that the energy of the soft radiation was about 14 keV. For the separation of lines, the selective absorption was determined in elements from Z = 28 to Z = 53. The results confirmed the attribution of the spectrum to the L-radiation of Ra. Similar measurements on radioactinium revealed the same lines with approximately the same intensities. In both cases a radium isotope is formed: /sub 90/Th/sup 230/(Io) ..-->.. /sub 88/Ra/sup 226/ ..-->.. ..cap alpha.., /sub 90/Th/sup 227/ (RaAc) ..-->.. /sub 88/Ra/sup 223/ (AcX) + ..cap alpha... The identity of the spectra shows that the atomic number of the formed atom alone determines the L-spectrum, and that in both cases the L level is excited as a result of an internal conversion of ..gamma..-lines: the line 68 keV in the case of ionium, eight lines 26-100 keV in that of radioactinium. On the basis of the intensities found, the relative numbers of photons corresponding to the levels L/sub I/, L/sub II/, and L/sub III/ could be calculated; they are L/sub I/:L/sub II/:L/sub III/ = 50:20:26. The ..gamma..-rays of ionium, as determined from the absorption in Cu, Ta, and Pb, are 68 and 200 kev. By assuming that the efficiency of the counters is equal to 1 - exp (-m..mu../rho), (where m is the efficient superficial mass of xenon, and ..mu../rho is the absorption coefficient in xenon), the intensities of the L- and ..gamma..-radiations of ionium can be given in terms of numbers of quanta per 100 disintegrations.

  2. Case study for co and counter swirling domestic burners

    Directory of Open Access Journals (Sweden)

    Ashraf Kotb

    2018-03-01

    Full Text Available In this case study, the influence of equivalence ratio for co and counter-swirl domestic burners compared with non-swirl design on the thermal efficiency as well as CO emissions has been studied using liquefied petroleum gas (LPG. Also, the flame stability, and pot height, which is defined as the burner-to-pot distance (H, of the co and counter domestic burners were compared. The analysis of the results showed that, for both swirl burners co and counter one the thermal efficiency under all operation conditions tested is higher than the non-swirled burner (base burner. For example, the thermal efficiency increased by 8.8%, and 5.8% than base burner for co and counter swirl, respectively at Reynolds number equal 2000 and equivalence ratio 1. The co and counter swirl burners show lower CO emission than the base burner. The co swirl burner has wider operation range than counter swirl. With the increase of pot height, the thermal efficiency of all burners decreases because the flame and combustion gases are cooled due to mixing with ambient air. As a result, the heat transfer is decreased due to atmospheric loss, which decrease the thermal efficiency.

  3. Portable counter for geological research

    Energy Technology Data Exchange (ETDEWEB)

    Russell, O J

    1949-05-01

    A portable counter which has been developed for prospecting for radio-active uranium and thorium minerals, for general geological investigations, and as an ultra-sensitive detector of lost or mislaid radium, is described. The aforementioned general usage includes the identification of changes in strata by means of the investigation of the slight amount of residual activity pressent in most minerals. The apparatus, which consists essentially of a scaled-down version of a standard laboratory Geiger-Muller counter, is highly sensitive since a variation equivalent to 4% of the cosmic ray background can be detected by a three-minute count.

  4. ''Conventional'' Cerenkov counters at ISABELLE

    International Nuclear Information System (INIS)

    Foley, K.J.

    1977-01-01

    Cherenkov counters to be used with ISABELLE are described. The three counters used in the Hadron Spectrometer can be used to identify particles in the range 10 to 40 GeV/c with pions separated from heavier particles down to approximately 3 GeV/c. A longer spectrometer for 400 x 400 GeV operation should also be used. The spectrometers may be used with CO 2 and H 2 . The range of particle identification of 8 to 60 GeV/c with pions separated from heavier particles down to approximately 5 GeV/c is possible

  5. Use of tissue equivalent proportional counters to characterize radiation quality on the space shuttle

    International Nuclear Information System (INIS)

    Braby, L.A.; Conroy, T.J.; Elegy, D.C.; Brackenbush, L.W.

    1992-04-01

    Tissue equivalent proportional counters (TEPC) are essentially cavity ionization chambers operating at low pressure and with gas gain. A small, battery powered, TEPC spectrometer, which records lineal energy spectra at one minute intervals, has been used on several space shuttle missions. The data it has collected clearly show the South Atlantic anomaly and indicate a mean quality factor somewhat higher than expected. An improved type of instrument has been developed with sufficient memory to record spectra at 10 second intervals, and with increased resolution for low LET events. This type of instrument will be used on most future space shuttle flights and in some international experiments

  6. Cosmic Ray Background Analysis For A Cargo Container Counter

    International Nuclear Information System (INIS)

    Ensslin, Norbert; Geist, W.H.; Lestone, J.P.; Mayo, D.R.; Menlove, Howard O.

    2001-01-01

    We have developed a new model for calculating the expected yield of cosmic-ray spallation neutrons in a Cargo Container Counter, and we have benchmarked the model against measurements made with several existing large neutron counters. We also developed two versions of a new measurement uncertainty prediction code based on Microsoft Excel spreadsheets. The codes calculate the minimum detectability limit for the Cargo Container Counter for either neutron singles or doubles counting, and also propagate the uncertainties associated with efficiency normalization flux monitors and cosmic ray flux monitors. This paper will describe the physics basis for this analysis, and the results obtained for several different counter designs.

  7. Micropipette as Coulter counter for submicron particles

    Science.gov (United States)

    Rudzevich, Yauheni; Ordonez, Tony; Evans, Grant; Chow, Lee

    2011-03-01

    Coulter counter based on micropipette has been around for several decades. Typical commercial Coulter counter has a pore size of 20 μ m, and is designed to detect micron-size blood cells. In recent years, there are a lot of interests in using nanometer pore size Coulter counter to detect single molecule and to sequence DNA. Here we describe a simple nanoparticle counter based on pulled micropipettes with a diameter of 50 -- 500 nm. Borosilicate micropipettes with an initial outer diameter of 1.00 mm and inner diameter of 0.5 mm are used. After pulling, the micropipettes are fire polished and ultrasound cleaned. Chlorinated Ag/AgCl electrodes and 0.1 M of KCl solution are used. The ionic currents are measured using an Axopatch 200B amplifier in the voltage-clamp mode. Several types and sizes of nanoparticles are measured, including plain silica and polystyrene nanospheres. The results will be discussed in terms of pH values of the solution and concentrations of the nanoparticles. Financial support from National Science Foundation (NSF-0901361) is acknowledged.

  8. Implementation of ISO 28218 quality system in the laboratory of body radioactivity counter CIEMAT

    International Nuclear Information System (INIS)

    Navarro Amaro, J. F.; Perez Lopez, B.; Lopez Ponte, M. A.; Perez Jimenez, C.

    2011-01-01

    The laboratory of body radioactivity counter has implemented IS0 28218 standard Performance Criteria for Radio bioassay in all measured in vivo techniques of internal contamination in the human organism in monitoring programs defined by the Personal Dosimetry Service Internal CIEMAT. The application of this rule in the laboratory's quality system is essential to meet the technical requirements of the standard IS0/IEC 17025 with the purpose of obtaining ENAC accreditation as a testing laboratory and calibration within the framework of the accreditation of Service CIEMAT Radiation Dosimetry. (Author)

  9. The Need for a United Nations Global Counter-Terrorism Coordinator

    Directory of Open Access Journals (Sweden)

    Howard Stoffer

    2013-08-01

    Full Text Available The case for a high level United Nations (UN Counter-Terrorism Coordinator position within the UN system has become increasingly urgent in 2013. This need has diluted some Member State reticence to creating a new Assistant Secretary-General position that would supervise and manage the existing counter-terrorism structures in the UN system. A Coordinator would have a basic responsibility to keep track of all of the activities of many formal inter-governmental organisations operating at the international, regional and sub-regional level and would also work closely with national counter-terrorism focal points. In this Policy Brief, Dr. Howard Stoffer reviews the debate among Security Council and Fifth Committee members about the efficacy of establishing a senior UN Global Counter-Terrorism Coordinator. He argues that the creation of such a position could lead to a restructuring of the UN counter-terrorism architecture as well as its funding within the UN budget and among donors. The position would eventually make the UN overall counter-terrorism effort, under the UN Global Counter-Terrorism Strategy, a stronger, more effective and more efficient process with measurable impact on the ground among Member States.

  10. Radiation detectors based by polymer materials

    International Nuclear Information System (INIS)

    Cherestes, Margareta; Cherestes, Codrut; Constantinescu, Livia

    2004-01-01

    Scintillation counters make use of the property of certain chemical compounds to emit short light pulses after excitation produced by the passage of charged particles or photons of high energy. These flashes of light are detected by a photomultiplier tube that converts the photons into a voltage pulse. The light emitted from the detector also can be collected, focussed and dispersed by a CCD detector. The study of the evolution of the light emission and of the radiation damage under irradiation is a primary topic in the development of radiation hard polymer based scintillator. Polymer scintillator thin films are used in monitoring radiation beam intensities and simultaneous counting of different radiations. Radiation detectors have characteristics which depend on: the type of radiation, the energy of radiation, and the material of the detector. Three types of polymer thin films were studied: a polyvinyltoluene based scintillator, fluorinated polyimide and PMMA. (authors)

  11. Lifetime characteristics of Gaiger-Muller counters

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad M.

    2016-01-01

    Full Text Available This paper discusses the process of functional aging of Geiger-Muller counters. Two types of Geiger-Muller counter chambers were characterized in an experiment using a combined constant voltage. Chamber A had a coaxial geometry and chamber B had a plan-parallel geometry. The experimental results indicate that the aging process was faster in the case of chambers with a coaxial geometry. The results are explained based on the process of electrical discharges in gasses.

  12. Recoil-proton fast-neutron counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R. (Padua Univ. (Italy). Ist. di Fisica); Galeazzi, G.; Bressanini, G.

    1981-12-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  13. Recoil-proton fast-neutron-counter telescope

    Energy Technology Data Exchange (ETDEWEB)

    Galeazzi, G.; Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Bressanini, G.

    1981-01-01

    A proton-recoil neutron counter telescope is described composed of a solid state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time-of-flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV, presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV.

  14. Test use of 'Ready Cap' for radiation measurement with a liquid scintillation counter

    International Nuclear Information System (INIS)

    Kato, Takahisa; Saito, Kazumi; Kurihara, Norio

    1989-01-01

    We tested the performance of 'Ready Cap' which can be used in place of liquid scintillation cocktails to measure the activity of 3 H and 14 C with a liquid scintillation counter, and observed satisfactory results on counting efficiencies for these nuclides. We could correct color-quenching with Ready Cap either by a method of the gravity-center of β-ray spectrum or by an external standard method that uses the external irradiation from bottom of the sample. Although there are several problems such as limitation of the maximum sample volumes (<200 μl) and sample preparation procedures (drying the sample solution), we can conveniently employ Ready Cap in some aspects of activity counting because of the easy disposal procedure of the radioactive waste resulting from it. (author)

  15. Presettable up-down CAMAC counter for 24 bit

    International Nuclear Information System (INIS)

    Kuhn, K.; Meyer, U.; Weidhase, F.

    1976-01-01

    A module containing a presettable binary up-down CAMAC counter for 24 bit is described. The use of dataway is discussed. As an example for application in nuclear physics, control of beam position by the up-down counter is illustrated

  16. Multi-level modelling of the response of the ultraminiature proportional counter: gas gain phenomena and pulse height spectra

    International Nuclear Information System (INIS)

    Olko, P.; Moutarde, C.; Segur, P.

    1995-01-01

    The ultraminiature proportional counters, UMC, unique radiation detectors for monitoring high intensity therapy fields, designed by Kliauga and operated at Columbia University (USA), have yielded a number of pulse height distributions for photons, neutrons and ions at simulated diameters of 5-50 nm. Monte Carlo calculations of the gas gain in such a counter questioned the possibility of achieving proportionally at such low simulated diameters. The response of the UMC has now been modelled taking into account both fluctuations of energy deposited in the counter volume and its calculated gas gain. Energy deposition was calculated using the MOCA-14, MOCA-8 and TRION codes, whereby distributions of ionisations d(j) after irradiations with 137 Cs, 15 MeV neutrons and 7 MeV.amu -1 deuterons were obtained. Monte Carlo calculations of electron avalanches in UMC show that the size of the single-electron avalanche P(n) reaching the anode depends strongly on the location of the primary ionisation within the counter volume. Distributions of the size of electron avalanches for higher numbers of primary ionisations, P *j (n), were obtained by successive convolutions of P(n). Finally, the counter response was obtained by weighting P *j (n) over d(j) distributions. On comparing the measured and calculated spectra it was concluded that the previously proposed single-electron peak calibration method might not be valid for the UMC due to the excessive width and overlap of electron avalanche distributions. Better agreement between the measured and calculated spectra is found if broader electron avalanche distributions than those used in the present calculations, are assumed. (author)

  17. Criticism and Counter-Criticism of Public Management: Strategy Models

    OpenAIRE

    Luis C. Ortigueira

    2007-01-01

    Critical control is very important in scientific management. This paper presents models of critical and counter-critical public-management strategies, focusing on the types of criticism and counter-criticism manifested in parliamentary political debates. The paper includes: (i) a normative model showing how rational criticism can be carried out; (ii) a normative model for oral critical intervention; and (iii) a general motivational strategy model for criticisms and counter-criticisms. The pap...

  18. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    International Nuclear Information System (INIS)

    Shin, W H; Park, T J

    2017-01-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea. (paper)

  19. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    Science.gov (United States)

    Shin, W. H.; Park, T. J.

    2017-06-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea.

  20. Discrimination capability of avalanche counters detecting different ionizing particles

    International Nuclear Information System (INIS)

    Prete, G.; Viesti, G.; Padua Univ.

    1985-01-01

    The discrimination capability of avalanche counters to detect different ionizing particles has been studied using a 252 Cf source. Pulse height, pulse-height resolution and timing properties have been measured as a function of the reduced applied voltage for parallel-plate and parallel-grid avalanche counters. At the highest applied voltages, space charge effects shift the pulse-height signal of the avalanche counter away from being linearly proportional to the stopping power of the detected particles and cause the pulse-height resolution to deteriorate. To optimize the avalanche counter capability, without loss of time resolution, it appears better to operate the detector at voltages well below the breakdown threshold. Measurements with 32 S ions are also reported. (orig.)

  1. Lessons from History for Counter- Terrorism Strategic Communications

    NARCIS (Netherlands)

    Ingram, H.J.; Reed, A.G.

    2016-01-01

    Drawing on the Counter-terrorism Strategic Communication (CTSC) Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of

  2. Proton-recoil proportional counter tests at TREAT

    International Nuclear Information System (INIS)

    Fink, C.L.; Eichholz, J.J.; Burrows, D.R.; DeVolpi, A.

    1979-01-01

    A methane filled proton-recoil proportional counter will be used as a fission neutron detector in the fast-neutron hodoscope. To provide meaningful fuel-motion information the proportional counter should have: a linear response over a wide range of reactor powers background ratio (the number of high energy neutrons detected must be maximized relative to low energy neutrons, and gamma ray sensitivity must be kept small); and a detector efficiency for fission neutrons above 1 MeV of approximately 1%. In addition, it is desirable that the detector and the associated amplifier/discriminator be capable of operating at counting rates in excess of 500 kHz. This paper reports on tests that were conducted on several proportional counters at the TREAT reactor

  3. Calibration Uncertainties in the Droplet Measurement Technologies Cloud Condensation Nuclei Counter

    Science.gov (United States)

    Hibert, Kurt James

    Cloud condensation nuclei (CCN) serve as the nucleation sites for the condensation of water vapor in Earth's atmosphere and are important for their effect on climate and weather. The influence of CCN on cloud radiative properties (aerosol indirect effect) is the most uncertain of quantified radiative forcing changes that have occurred since pre-industrial times. CCN influence the weather because intrinsic and extrinsic aerosol properties affect cloud formation and precipitation development. To quantify these effects, it is necessary to accurately measure CCN, which requires accurate calibrations using a consistent methodology. Furthermore, the calibration uncertainties are required to compare measurements from different field projects. CCN uncertainties also aid the integration of CCN measurements with atmospheric models. The commercially available Droplet Measurement Technologies (DMT) CCN Counter is used by many research groups, so it is important to quantify its calibration uncertainty. Uncertainties in the calibration of the DMT CCN counter exist in the flow rate and supersaturation values. The concentration depends on the accuracy of the flow rate calibration, which does not have a large (4.3 %) uncertainty. The supersaturation depends on chamber pressure, temperature, and flow rate. The supersaturation calibration is a complex process since the chamber's supersaturation must be inferred from a temperature difference measurement. Additionally, calibration errors can result from the Kohler theory assumptions, fitting methods utilized, the influence of multiply-charged particles, and calibration points used. In order to determine the calibration uncertainties and the pressure dependence of the supersaturation calibration, three calibrations are done at each pressure level: 700, 840, and 980 hPa. Typically 700 hPa is the pressure used for aircraft measurements in the boundary layer, 840 hPa is the calibration pressure at DMT in Boulder, CO, and 980 hPa is the

  4. Construction and calibration studies of the SAPHIR scintillation counters

    International Nuclear Information System (INIS)

    Kostrewa, D.

    1988-03-01

    For the scintillation counter system of the SAPHIR detector at the stretcher ring ELSA in Bonn 50 time of flight counters and 12 trigger counters have been built. Each of them has two photomultipliers, one at each side. A laser calibration system with a pulsed nitrogen laser as central light source to monitor these photomultipliers has been optimized. It was used to adjust the photomultipliers and to test their long and short time instabilities. (orig.)

  5. An extended range neutron rem counter

    International Nuclear Information System (INIS)

    Birattari, C.; Nuccetelli, C.; Pelliccioni, M.; Silari, M.

    1990-01-01

    Extensive Monte Carlo calculations have been carried out to assess the possibility of extending the sensitivity of a neutron rem counter of the Andersson-Braun type up to several hundred MeV. The validity of the model adopted has first been checked by comparing with experimental data the calculated response curve and the angular dependence of the sensitivity for a well known commercial rem counter. Next, a number of modifications to the configuration of the moderator-attenuator have been investigated. The response functions and angular distributions produced by two simple solutions yielding an instrument with a sensitivity extended up to 400 MeV are presented. The response of the original rem counter and of its two modified versions to nine test spectra has also been calculated. The resulting instrument is transportable rather than portable, but the availability of an extended range neutron survey meter would be of great advantage at medium and high energy particle accelerator facilities. (orig.)

  6. Pulse-duration discrimination for increasing counting characteristic plateau and for improving counting rate stability of a scintillation counter

    International Nuclear Information System (INIS)

    Kuz'min, M.G.

    1977-01-01

    For greater stability of scintillation counters operation, discussed is the possibility for increasing the plateau and reducing its slope. Presented is the circuit for discrimination of the signal pulses from input pulses of a photomultiplier. The counting characteristics have been measured with the scintillation detectors being irradiated by different gamma sources ( 60 Co, 137 Cs, 241 Am) and without the source when the scintillation detector is shielded by a tungsten cylinder with a wall thickness of 23 mm. The comparison has revealed that discrimination in duration increase the plateau and reduces its slope. Proceeding from comparison of the noise characteristics, the relationship is found between the noise pulse number and gamma radiation energy. For better stability of the counting rate it is suggested to introduce into the scintillation counter the circuit for duration discrimination of the output pulses of a photomultiplier

  7. A gridded air counter for measuring exoelectrons

    International Nuclear Information System (INIS)

    Nagase, Makoto; Chiba, Yoshiya; Kirihata, Humiaki.

    1980-01-01

    A gridded air counter with a quenching circuit is described, which serves to detect low-energy electrons such as thermionic electrons, photoelectrons and exoelectrons emitted into the atmospheric air. The air counter consists of a loop-shaped anode and two grids provided for quenching the gas discharge and for protecting the electron emitter from the positive ion bombardment. The quenching circuit with a high input sensitivity of 5 mV detects the initiation gas discharge caused by an incident electron and immediately supplies a rectangular wave pulse of 300 V in amplitude and of more than 3 msec in width to the quenching grid near the anode. Simultaneously, the voltage of the suppressor grid is brought down and kept at -30 V against the earthed sample for the same period of time. Performance of the gridded air counter was examined by use of photoelectrons emitted from an abraded aluminum plate. The quenching action was successfully accomplished in the anode voltage range from 3.65 to 3.95 kV. The photoelectrons emitted into the atmosphere could be counted stably by use of this counter. (author)

  8. Helium-air counter flow in rectangular channels

    International Nuclear Information System (INIS)

    Fumizawa, Motoo; Tanaka, Gaku; Zhao, Hong; Hishida, Makoto; Shiina, Yasuaki

    2004-01-01

    This paper deals with numerical analysis of helium-air counter flow in a rectangular channel with an aspect ratio of 10. The channel has a cross sectional area of 5-50 mm and a length of 200 mm. The inclination angle was varied from 0 to 90 degree. The velocity profiles and concentration profiles were analyzed with a computer program [FLUENT]. Following main features of the counter flow are discussed based on the calculated results. (1) Time required for establishing a quasi-steady state counter flow. (2) The relationship between the inclination angle and the flow patterns of the counter flow. (3) The developing process of velocity profiles and concentration profiles. (4) The relationship between the inclination angle of the channel and the velocity profiles of upward flow and the downward flow. (5) The relationship between the concentration profile and the inclination angle. (6) The relationship between the net in-flow rate and the inclination angle. We compared the computed velocity profile and the net in-flow rate with experimental data. A good agreement was obtained between the calculation results and the experimental results. (author)

  9. Personal dosimetry at the radiation accidents

    International Nuclear Information System (INIS)

    Perevoznikov, O.N.; Klyuchnikov, A.A.; Kanchenko, V.A.

    2007-01-01

    The radiation accidents of different types and the methods of the dosimetry used at the consequences liquidation are considered. The long-term experience of the population personal instrumental dosimetric control carrying out at the ChNPP accident consequences liquidation is widely covered in details. The concepts are stated out and the results are presented on the functioning of the created system for personal dose monitoring of the population of Ukraine irradiation. The use of the person radiation counters at the internal irradiation population and personal dose assessment is considered in details

  10. Reactance and Coping Responses to Tobacco Counter-Advertisements.

    Science.gov (United States)

    Wehbe, Michelle S; Basil, Michael; Basil, Debra

    2017-07-01

    Tobacco prevention messages generally take one of three tactics: They can be educational, attack the tobacco industry, or attack particular brands. Being a smoker and smoking a particular brand may form an essential part of a person's self-identity. As such, reactance theory suggests that attack messages can unintentionally attack smokers' self-image. A 2 × 2 × 2 × 2 experiment using six different messages and 260 respondents tested whether smokers have different reactions to tobacco counter-advertisements than nonsmokers. It also examined whether attacking a smoker's brand leads to greater reactance and other maladaptive responses compared to attacking other brands. Consistent with predictions, smokers reported more maladaptive coping responses and fewer adaptive coping responses to tobacco counter-ads than nonsmokers. The study also reveals differences attributable to brand identification. These findings suggest that interventions should consider different counter-advertising tactics for smokers and nonsmokers. Similar admonitions may apply to counter-advertising strategies on other health issues.

  11. Electromagnetically Operated Counter

    Science.gov (United States)

    Goldberg, H D; Goldberg, M I

    1951-12-18

    An electromagnetically operated counter wherein signals to be counted are applied to cause stepwise rotation of a rotatable element which is connected to a suitable register. The mechanism involved consists of a rotatable armature having three spaced cores of magnetic material and a pair of diametrically opposed electromagnets with a suitable pulsing circuit to actuate the magnets.

  12. Cross-talk of a multi-anode PMT and attainment of a σ∼10ps TOF counter

    International Nuclear Information System (INIS)

    Enari, Y.; Hayasaka, K.; Hokuue, T.; Inami, K.; Ohshima, T.; Sato, N.; Akatsu, M.; Kawakami, S.; Miyabayashi, Y.; Tokuda, H.; Yanase, H.; Shimoi, H.; Fujimori, T.

    2005-01-01

    We extensively studied a cross-talk phenomenon that seriously deteriorates the high time-resolution of a multi-anode 16-channel linear array photo-multiplier tube (PMT); the dynode structures were modified to eliminate the cross-talk effect and to recover a time resolution of σ=70-80ps for single photons. The use of 16 anode signals of the modified PMT enabled us to attain σ=12ps for a small TOF counter of Cherenkov radiation

  13. Hardware support for software controlled fast reconfiguration of performance counters

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2013-06-18

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  14. 'Miniskirt' counter array at CDF II

    International Nuclear Information System (INIS)

    Artikov, A.; Artikov, A.

    2006-01-01

    Full text: Muon detection is fundamental for the most of the interesting analyses at CDF. At the course of Run II, the collaboration expects to collect hundreds of t t-bar decays yielding a muon as well as several million B-hadron events involving J/ψ → μ + μ - decays. Muon detection is also of fundamental importance in the study of W-boson properties and in the search for Higgs production associated with W or Z bosons. Considerable effort therefore went into extending the muon detector coverage for Run II, which started in March 2001. The CDF II muon detector system consists of multiple layers of drift chambers and scintillation counters, which span the pseudorapidity (|η|) range between 0 and 1.5. Detectors spanning different ranges have different geometries, and the muon scintillation counter system includes subsystems in the regions that have come to be known as the 'central' (0 pe for WLS fiber readout is smaller than for conventional readout, we can also expect an increase in the statistical contribution to the overall uncertainty. Our first concern, before adopting this solution, was therefore to ascertain that the mean timing resolution obtained under these conditions was adequate. The modifications, testing and installation of these counters within the CDF Upgrade Project are described in detail. The timing characteristics of MSX' counters are also investigated using cosmic muons. The measurements show that the time resolution does not exceed 2.2 ns. (author)

  15. Responding to Cyber Jihad: Towards an Effective Counter Narrative

    Directory of Open Access Journals (Sweden)

    Bibi van Ginkel

    2015-03-01

    Full Text Available “Who is in control of the narrative?” is the mantra that now echoes in the hallways of the EU’s headquarters in Brussels. Spurred in part by large-scale jihadist propaganda, approximately 20,000 people from 50 countries have joined the fight in Iraq and Syria. So far, authorities in their countries of origin have not been able to address the jihadist radicalisation messages transmitted via the internet and social media. Many new initiatives were recently announced, however, including the establishment of a European counter-narrative centre in Brussels. Research Fellow Dr. Bibi van Ginkel analyses the role of the internet and social media in processes of radicalisation. It offers an outline of the various aspects of the jihadist narrative, in order better to understand what message needs to be countered. The counter-actions against this cyber jihad can take different forms. Parallel to the way in which advertisement campaigns are tailored to sell products to a certain target group, strategic communication should take into account how a number of recurring elements play a role in the counter-messaging. The understanding of who the target group is, what jihadist narrative is used and how that message can be countered, who the credible messenger should be, and what medium can best be used to deliver the message are all relevant questions that can only be answered in a context-specific manner. The Research Paper concludes with several recommendations on how the recently announced new European counter-narrative centre can effectively contribute to the already diverse landscape of counter-narrative initiatives.

  16. Applications of noble gas radiation detectors to counter-terrorism

    International Nuclear Information System (INIS)

    Vanier, Peter E.; Forman, Leon

    2002-01-01

    Radiation detectors are essential tools in the detection, analysis and disposition of potential terrorist devices containing hazardous radioactive and/or fissionable materials. For applications where stand-off distance and source shielding are limiting factors, large detectors have advantages over small ones. The ability to distinguish between Special Nuclear Materials and false-positive signals from natural or man-made benign sources is also important. Ionization chambers containing compressed noble gases, notably xenon and helium-3, can be scaled up to very large sizes, improving the solid angle for acceptance of radiation from a distant source. Gamma spectrometers using Xe have a factor of three better energy resolution than NaI scintillators, allowing better discrimination between radioisotopes. Xenon detectors can be constructed so as to have extremely low leakage currents, enabling them to operate for long periods of time on batteries or solar cells. They are not sensitive to fluctuations in ambient temperature, and are therefore suitable for deployment in outdoor locations. Position-sensitive 3He chambers have been built as large as 3000 cm2, and with spatial resolution of less than 1 mm. Combined with coded apertures made of cadmium, they can be used to create images of thermal neutron sources. The natural background of spallation neutrons from cosmic rays generates a very low count rate, so this instrument could be quite effective at identifying a man-made source, such as a spontaneous fission source (Pu) in contact with a moderator (high explosive)

  17. Countering the ‘Natural’ Organizational Self on Social Media

    DEFF Research Database (Denmark)

    Johansen, Trine Susanne

    2017-01-01

    , challenge and contradict organizational self-narration in light of market place skepticism and cynicism. The study identifies three strategies of counter-narrativizing (authenticity, legitimacy and irony) based on juxtaposing pairs of opposites. Moreover, it suggests counter-narration to be a natural......Using narrative as a theoretical and methodological lens, this study explores digital processes of organizational identity construction in the intersection between organization and market.The purpose is to understand the ways in which online interactions produce counter-narratives that contrast...

  18. Sources of Brazil's Counter-Hegemony

    Directory of Open Access Journals (Sweden)

    Marcos Aurelio Guedes de Oliveira

    2010-01-01

    Full Text Available There have been two key initiatives taken in the last two decades in Brazil to create a counter-hegemonic project for the country. One initiative resulted from Brazil's business community and high-level State bureaucracy and aimed at forming a regional economic and political bloc that would guarantee and enlarge a relative independence from the hegemonic powers. The other resulted from the emergence of the new unionist movement in São Paulo and from the formation of Partido dos Trabalhadores and aimed at promoting radical democratization and reducing social exclusion. Both initiatives have created policies and changes that have converged to enhance Brazil's counter-hegemonic position as a regional and emerging power.

  19. Description of the manufacture of a Geiger-Muller counter with window

    International Nuclear Information System (INIS)

    Granados, C. E.

    1959-01-01

    Total details about the manufacture elements in counter fabrication and the way of obtention are described as well as total indications useful in the installation process and filling of the counter. The appropriate materials and precautions that might be adopted in order to obtain counters with uniform operation and good characteristics, are described. Counters are of brass, with thin mica or aluminium windows and operate at 1100 V approximately with a slope lower than 5 % 1100 V. (Author)

  20. The Counter Terrorist Classroom: Religion, Education, and Security

    Science.gov (United States)

    Gearon, Liam

    2013-01-01

    The article identifies international cases--from the United States, Europe, and the United Nations--of an emergent interface of religion, education, and security. This is manifest in the uses of religion in education to counter religious extremism, the notional "counter terrorist classroom." To avoid an over-association of extremism with…

  1. Counter-Buffing: A Visual Criticism of Guerrilla Advertising

    Science.gov (United States)

    Lauzon, Robb Conrad; Cooke, Laquana

    2017-01-01

    This article addresses and explores hip-hop's reclamation of space using transit as a public bulletin. It is situated within counter-publics discourse and couched in the theoretical frameworks offered by visual rhetorical theory. This article also discusses hip-hop counter-publics through guerrilla advertising by former graffiti artists, SKI and…

  2. The IFIN-HH triple coincidence liquid scintillation counter

    CSIR Research Space (South Africa)

    Razdolescu, AC

    2006-10-01

    Full Text Available at IFIN-HH using a 3 H standard. The performances of the IFIN-HH TDCR counter was checked against the measurement results of the TDCR counters of CSIR NML (South Africa), RC (Poland) and LNHB (France). A set of ready-to-measure Ni-63 sources in liquid...

  3. Portable single channel analyzer incorporated with a GM counter for radiation protection

    International Nuclear Information System (INIS)

    Chenghsin Mao

    1988-01-01

    A compact size of single channel analyzer incorporated with a GM counter has been developed. It measures 8.7 cm (W) x 22.2 cm (L) x 4.4 cm (H) and weighs 0.58 kg excluding the detectors. An adjustable high voltage of 0-1000 V is included with an error of ± 0.1% and powered by three mercury batteries of 9 V each. Both the upper and lower level discriminators are set at 0 - 5 V with an error of ± 1%. The timer can be set at either 0 - 99 sec or 0 - 99 min with a buzzer alarm. The resolution of pulse is 5 μs plus the pulse width. The LCD display is either 3 1/2 or 4 digits. The rise time of shaping circuit is 1 μs with a band width of 350 kHz. The voltage indicator for battery is set at 7.5 V. All integrated circuits are of CMOS with low cost OPAMP. Some examples for field applications are given

  4. Picosecond-precision multichannel autonomous time and frequency counter

    Science.gov (United States)

    Szplet, R.; Kwiatkowski, P.; RóŻyc, K.; Jachna, Z.; Sondej, T.

    2017-12-01

    This paper presents the design, implementation, and test results of a multichannel time interval and frequency counter developed as a desktop instrument. The counter contains four main functional modules for (1) performing precise measurements, (2) controlling and fast data processing, (3) low-noise power suppling, and (4) supplying a stable reference clock (optional rubidium standard). A fundamental for the counter, the time interval measurement is based on time stamping combined with a period counting and in-period two-stage time interpolation that allows us to achieve wide measurement range (above 1 h), high precision (even better than 4.5 ps), and high measurement speed (up to 91.2 × 106 timestamps/s). The frequency is measured up to 3.0 GHz with the use of the reciprocal method. Wide functionality of the counter includes also the evaluation of frequency stability of clocks and oscillators (Allan deviation) and phase variation (time interval error, maximum time interval error, time deviation). The 8-channel measurement module is based on a field programmable gate array device, while the control unit involves a microcontroller with a high performance ARM-Cortex core. An efficient and user-friendly control of the counter is provided either locally, through the built-in keypad or/and color touch panel, or remotely, with the aid of USB, Ethernet, RS232C, or RS485 interfaces.

  5. Development of a detector-counter for teaching purposes in nuclear instrumentation

    International Nuclear Information System (INIS)

    Costa, Fabio E. da; Hamada, Margarida M.; Pereira, Maria Conceicao C. Pereira; Mesquita, Carlos H.

    2000-01-01

    A detector system constituted of a monochannel analyzer with digital counter, amplifier, charge sensitive preamplifier and CsI(Tl) scintillator detector coupled to photodiode PIN was developed to gamma radiation detection. The crystal was grown by Bridgman Method. The crystal luminescence spectra has good match with the photodiode efficiency spectrum. The combination CsI(Tl)- photodiode made at possible to obtain a compact and rugged detector, insensitive to magnetic fields and may be operated at low voltages. This detector system has a baseline for 1 MeV and 2 MeV selected by the use, with two discriminators (inferior and superior) for advancements 10 or 20 KeV division. The system showed good energy linearity in the range from 122 to 1440 KeV. (author)

  6. Dimensions of Counter-Narratives

    DEFF Research Database (Denmark)

    2019-01-01

    The book welcomes proposals for chapter contributions on a wide array of topics related to the narratological notion of counter-narratives. By way of example, the topic has hitherto been treated by disciplines and subjects such as literature studies, organization studies, corporate communication...

  7. Technical Note: Characterization of a static thermal-gradient CCN counter

    Directory of Open Access Journals (Sweden)

    G. P. Frank

    2007-06-01

    Full Text Available The static (parallel-plate thermal-gradient diffusion chamber (SDC was one of the first instruments designed to measure cloud condensation nuclei (CCN concentrations as a function of supersaturation. It has probably also been the most widely used type of CCN counter. This paper describes the detailed experimental characterization of a SDC CCN counter, including calibration with respect to supersaturation and particle number concentration. In addition, we investigated the proposed effect of lowered supersaturation because of water vapor depletion with increasing particle concentration. The results obtained give a better understanding why and in which way it is necessary to calibrate the SDC CCN counter. The calibration method is described in detail and can, in parts, be used for calibrations also for other types of CCN counters.

    We conclude the following: 1 it is important to experimentally calibrate SDC CCN counters with respect to supersaturation, and not only base the supersaturation on the theoretical description of the instrument; 2 the number concentration calibration needs to be performed as a function of supersaturation, also for SDC CCN counter using the photographic technique; and 3 we observed no evidence that water vapor depletion lowered the supersaturation.

  8. Neutron time-of-flight counters and spectrometers for diagnostics of burning fusion plasmas

    International Nuclear Information System (INIS)

    Elevant, T.; Olsson, M.

    1991-02-01

    Experiment with burning fusion plasmas in tokamaks will place particular requirements on neutron measurements from radiation resistance-, physics-, burn control- and reliability considerations. The possibility to meet these needs by measurements of neutron fluxes and energy spectra by means of time-of-flight techniques are described. Reference counters and spectrometers are proposed and characterized with respect to efficiency, count-rate capabilities, energy resolution and tolerable neutron and γ-radiation background levels. The instruments can be used in a neutron camera and are capable to operate in collimated neutron fluxes up to levels corresponding to full nuclear output power in the next generation of experiments. Energy resolutions of the spectrometers enables determination of ion temperatures from 3 (keV) through analysis of the Doppler broadening. Primarily, the instruments are aimed for studies of 14 (MeV) neutrons produced in (d,t)-plasmas but can, after minor modifications, be used for analysis of 2.45 (MeV) neutrons produced in (d,d)-plasma. (au) (33 refs.)

  9. Possibility of semiconductor counters application for internal contamination measurement of whole human body

    International Nuclear Information System (INIS)

    Cunic, O.; Orlic, M.; Bek-Uzarov, Dj.; Pavlovic, S.; Pavlovic, R.

    1997-01-01

    The possibility of high resolution semiconductor counters application in 'Vinca' Whole Body Counter for direct beta-gamma internal contamination measurement are discussed, assuming the following relevant characteristics: efficiency, resolution and counter price. A comparison with appropriate characteristics of NaI(Tl) crystal used in 'Vinca' WBC is treated. It is evident that the scintillation counters have the higher detection efficiency, but HPGe counters having much better resolution and recently lowest prices are also acceptable to join the existing NaI(Tl) counters with the HPGe counters in the same time, allow better spectral analyses of the human body activity and additionally more precise estimation of the equivalent doses rate which is generally a essential problem in WBC measurements. (author)

  10. The research on the failure regularity of GM counter tubes

    International Nuclear Information System (INIS)

    Li Jiyuan; Huai Guangli; Xie Bo; Zhang Hao

    2002-01-01

    The reliability of GM counter tubes should be described by useful time before failure-life and failure rate during life. A new method to study the failure regularity of GM counter tubes is advanced and adopted. The essential point of the method is that after the GM counter tubes of the instruments in use is tested, both the performance parameters and other information of the GM counter tubes and the instruments collected are recorded. Then database is created. Failure criterion is ascertained. The GM counter tubes are inspected to determine whether they are failure. Failure mode should be decided if the GM counter tubes failure. The GM counter tubes with the same useful year come together to make up a subsample. According to the relevant information, the number of the subsample is restored to the number of the sample that initially put into use. Then the number of failure sample is counted and at the same time the distribution of failure mode is got. The parameter m, γ, t 0 of Weibull distribution function are calculated with method of linear fit. Thus mean life, failure rate and other character values are obtained. Using this method, useful life and failure rate are determined. The conclusion is that the useful life is 18-20 years and the failure rate is 5 x 10 -6 and 4 x 10 -6 /h respectively during the course

  11. On timing properties of the SRPO-304 proportional counters

    International Nuclear Information System (INIS)

    Gusev, A.A.; Pugacheva, G.I.

    1979-01-01

    Data of measurements of the signal delay time and the time of development of the discharge in a proportional counter filled with 90% Xe + 10% CH 4 mixture at 0.3 atm are presented. The measurements were carried out on muons of cosmic rays. Signal delay distribution for the proportional counter are given relative to the time of passage through it of a charged particle. The data obtained shows that the average delay time is 0.8 μs when a particle passes near the counter centre, whereas when it passes near its side wall the average delay time is 1.5 μs. The investigation of the discharge development time distribution was carried out for two values of the discriminator threshold: 6 and 20 keV. It was determined that the discharge development time distribution depends but little on the place of particle passage in a counter. The average discharge development time is 1.5 μs, with the maximum time beina 4.3 μs. It is shown that the resolution time of logical circuits will be near 4 μs when the counter is combined with scintillation detectors

  12. Microchip Coulter particle counter

    DEFF Research Database (Denmark)

    Larsen, Ulrik Darling; Blankenstein, Gert; Branebjerg, J.

    1997-01-01

    This paper presents a micro device employing the Coulter principle for counting and sizing of living cells and particles in liquid suspension. The microchip Coulter particle counter (μCPC) has been employed in a planar silicon structure covered with glass, which enables detailed observation during...

  13. New proportional counter assembly in Gliwice 14C laboratory

    International Nuclear Information System (INIS)

    Moscicki, W.; Zastawny, A.

    1977-01-01

    The design and parameters are described of a proportional counter for low level counting. The cathode tube 80 mm in diameter and 30 cm in length is made of pure copper. The anode is a tungsten wire 0.05 mm in diameter. The cathode tube is surrounded by a cylindrical ring container with mercury. The total volume of the counter is 1.5 l and it is filled with carbon dioxide. At a pressure of 1 at of CO 2 the counter background is 4.20+-0.05 cpm and contemporary 14 C net effect 10.22+-0.10 cpm; at a pressure of 2 at of CO 2 the background is 4.40+-0.05 cpm and the contemporary 14 C net effect 20.53+-10 cpm. The efficiency of the proportional counter is 88% in both cases. (J.B.)

  14. USB-based radiation monitor

    International Nuclear Information System (INIS)

    Drndarevic, V.; Jevtic, N.; Djuric, R.

    2006-01-01

    The Universal Serial Bus has become a dominant interface for the connection of standard peripheral devices to a personal computer. This paper analyzes the possibilities of USB bus applications in the field of measurement and environmental monitoring. As a result, a gamma radiation monitor consisting of an USB-based universal peripheral device and a gamma probe with a GM counter, has been designed. For the interfacing monitor with the powerful and easy to use LabVIEW software package, an instrument driver as a set of virtual instruments has been developed. The proposed monitor is a flexible instrument which can be used for laboratory measurements, as an environmental radiation monitor or for training purposes. Connected to the laptop computer, the monitor becomes a portable instrument suitable for field measurements. Basic measurements and functionality properties of the radiation monitor are presented here

  15. Proportional counter with a wire-anode lying on the dielectric surface

    International Nuclear Information System (INIS)

    Strelkov, A.V.

    1983-01-01

    Proportional coUnter with wire-anode lying on the dielectric surface is described. The result of the accumulation of charges on the dielectric surface immediately near the wire-anode surface is that such a counter possesses electrostatic memory relative to distribution of the gas amplification coefficient along the anode. SUch a distribution can be received for example by means of irradiation by the neutrons or the γ-rays. The disposition of the wire-anode on the convex dielectric surface allows one to make the ring-shaped counters or the nonplane proportional chambers practically of any profile. However, the energy resolution of the counter with anode on the dielectric is worse than the resolution of counter with free anode particularly at the large gas amplification coefficient

  16. Lessons from History for Counter-Terrorism Strategic Communications

    Directory of Open Access Journals (Sweden)

    Haroro J. Ingram

    2016-06-01

    Full Text Available Drawing on the Counter-terrorism Strategic Communication (CTSC Project’s research paper “A Brief History of Propaganda during Conflict“, this Policy Brief lays out the key policy-relevant lessons for developing effective counter-terrorism strategic communications. It presents a framework of interrelated macro-, mezzo- and micro-level considerations for maximizing the efficacy of not just a strategic communications campaign but message design. Historical examples are drawn upon to illustrate their practical application. The Policy Brief concludes by analysing four key strategic-policy principles arguing that a counter-terrorism strategic communications campaign is more likely to be successful if it is based on the cumulative effects of a multidimensional messaging strategy.

  17. 4-GHz counters bring synthesizers up to speed

    Science.gov (United States)

    Lee, F.; Miller, R.

    1984-06-01

    The availability of digital IC counters built on GaAs makes direct frequency division in microwave synthesizers possible. Four GHz is the highest clock rate achievable in production designs. These devices have the ability to drive TTL/CMOS logic, and the counter can be connected directly to single-chip frequency synthesizers controllers. A complete microwave sythesizer is formed by two chips and a voltage-controlled oscillator (VCO). The advantages of GaAs are discussed along with flip-flop basics, aspects of device fabrication, and the characteristics of GaAs MESAFETs. Attention is given to a GaAs prescaler usable for direct conversion, four kinds of flip-flops in a divide-by-two mode, and seven-stage binary ripple counters.

  18. Analysis of Cherenkov counter efficiencies for E691

    International Nuclear Information System (INIS)

    Cremaldi, L.; Elliott, J.; Gibney, M.; Nauenberg, U.

    1985-01-01

    A program is outlined which simulates Cherenkov counters. The program can compute the effect of the magnetic field on the efficiencies of Cherenkov counters. It also tells what cone to mirror distance gives the highest collection efficiency and at which target position should the laser be placed to represent the direction of the actual Cherenkov light the mirror sees

  19. X-ray proportional counter for the Viking Lander

    International Nuclear Information System (INIS)

    Glesius, F.L.; Kroon, J.C.; Castro, A.J.; Clark, B.C.

    1978-01-01

    A set of four sealed proportional counters with optimized energy response is employed in the X-ray fluorescence spectrometer units aboard the two Viking Landers. The instruments have provided quantitative elemental analyses of soil samples taken from the Martian surface. This paper discusses the design and development of these miniature proportional counters, and describes their performance on Mars

  20. Geiger-Mueller haloid counter dead time dependence on counting rate

    International Nuclear Information System (INIS)

    Onishchenko, A.M.; Tsvetkov, A.A.

    1980-01-01

    The experimental dependences of the dead time of Geiger counters (SBM-19, SBM-20, SBM-21 and SGM-19) on the loading, are presented. The method of two sources has been used to determine the dead time counters of increased stability. The counters are switched on according to the usually used circuit of discrete counting with loading resistance of 50 MOhm and the separating capacity of 10 pF. Voltage pulses are given to the counting device with the time of resolution of 100 ns, discrimenation threshold 3 V, input resistance 3.6 Ω and the input capacity-15 pF. The time constant of the counter RC-circuit is 50 μs

  1. Construction techniques and working principles of external cathode Geiger-Mueller counters

    International Nuclear Information System (INIS)

    Sevegnani, Francisco Xavier

    1996-01-01

    In this paper, the construction technique and working principles of the external cathode Geiger-Mueller counter are described in detail. During the analysis of the behavior of these counters a new phenomena was observed, related to an increase int he background rate with the applied voltage. The experiments have also shown that the pulse amplitude of those counters decreases exponentially with the counting rate. The counters built with the techniques described in this paper has shown plateaus of about 1400 V with slope of 0,8%/100 V. (author)

  2. Laboratory training manual on the use of isotopes and radiation in entomology. 2. ed.

    International Nuclear Information System (INIS)

    1977-01-01

    The revised manual, which incorporates changes particularly regarding applied aspects, consists of 7 parts. Part 1 is divided into separate chapters on the properties of radionuclides and radiations; radiation detection and assay of radioactivity; radiation protection; tracer methodology; 15 N determination; and neutron moderation and γ-ray attentuation techniques. Part 2 is concerned with radiobiology. References and a bibliography are supplied with each part. Part 3 contains 17 mental exercises, part 4 laboratory exercises on a GM counter; a scintillation counter; contamination and decontamination; and exercises on basic utilization principles. Part 5 considers radioisotope uptake and excretion paths through the insect organism; principles of internal and external tagging; with emphasis on insect physiology and ecology; various experiments on insects, and insect sterilization using 60 Co and chemosterilants. Eight Appendices and a Glossary of some basic terms and concepts constitute parts 6 and 7, respectively

  3. Sculptured platinum nanowire counter electrodes for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyeonseok [Department of Electrical Engineering, Pennsylvania State University, University Park 16802 (United States); Horn, Mark W., E-mail: MHorn@engr.psu.edu [Department of Engineering Science and Mechanics, Pennsylvania State University, University Park 16802-6812 (United States)

    2013-07-01

    Sculptured platinum nanowire thin films were formed by oblique angle electron beam evaporation with a 5° vapor incidence angle and incorporated as counter electrodes for dye-sensitized solar cells (DSSCs). For the comparison of the performance, bare fluorine doped tin oxide, planar Pt electrodes and counter electrodes treated with chloroplatinic acid were prepared. The sculptured Pt nanowire electrodes showed five times lower charge transfer resistance (0.121 [Ω∗cm{sup 2}]) than that of Pt planar electrode (0.578 [Ω∗cm{sup 2}]) and when the Pt nanowire electrodes are treated with an H{sub 2}PtCl{sub 6} solution have more than ten times lower charge transfer resistance (0.04025 [Ω∗cm{sup 2}]). Moreover, Pt nanowire films used as a counter electrode lead to enhancement in current density and efficiency in comparison with Pt planar counter electrodes. The conversion efficiency with planar electrodes was 5.1 [%] while the efficiency of DSSC with platinum nanowire counter electrodes reached to 5.63 [%] under AM 1.5 illumination. - Highlights: • Pt sculptured thin films (STFs) fabricated by electron beam evaporator. • The STFs featured higher roughness and lower charge transfer resistance. • Improved performance of dye-sensitized solar cells by Pt STFs counter electrodes.

  4. Development of a Mobile Ice Nucleus Counter

    Energy Technology Data Exchange (ETDEWEB)

    Kok, Gregory [Droplet Measurement Technologies, Boulder, CO (United States); Kulkarni, Gourihar [Droplet Measurement Technologies, Boulder, CO (United States)

    2014-07-10

    An ice nucleus counter has been constructed. The instrument uses built-in refrigeration systems for wall cooling. A cascade refrigeration system will allow the cold wall to operate as low as -70°C, and a single stage system can operate the warm wall at -45C. A unique optical particle counter has been constructed using polarization detection of the scattered light. This allows differentiation of the particles exiting the chamber to determine if they are ice or liquid.

  5. A recoil-proton fast-neutron counter telescope

    International Nuclear Information System (INIS)

    Pavan, P.; Toniolo, D.; Zago, G.; Zannoni, R.; Galeazzi, G.; Bressanini, G.

    1981-01-01

    A recoil-proton neutron counter telescope is described composed of a solid-state silicon transmission detector and a NE 102 A plastic scintillator, measuring the energy loss, the energy of the recoil protons and the time of flight between the two detectors. The counter exposed to monoenergetic neutron beams of energy from 6 to 20 MeV presents a low background and a moderate energy resolution. Its absolute efficiency is calculated up to 50 MeV. (author)

  6. Radiophobia [Radiation Protection Journal, v.4 (2015)

    International Nuclear Information System (INIS)

    Vasilev, Georgi

    2015-01-01

    Man is conscious of his own existence and it certainly influences the acceptance or non-acceptance of some facts and activities. In this respect, undoubtedly paramount importance is the feeling of fear. This article addresses the issue of radiophobia: origin, instances, characteristics of ionizing radiation, which serve as preconditions for radiophobia. Formulates some recommendations for countering radiophobia

  7. INTRODUCING OVER THE COUNTER COUNSELING

    Directory of Open Access Journals (Sweden)

    Nataša Bakić-Mirić

    2009-01-01

    Full Text Available A pharmacist in today’s world has a great responsibility – to help and educate patients about diverse ways for effective self-treatment. Whereas self-care is becoming increasingly popular among patients today the availability of over-the-counter medications makes it possible for patients to treat numerous conditions on their own but still under the supervision of a healthcare provider. During the pharmacist-patient encounter, the pharmacist’s obligation is to evaluate the patient’s medical condition, provide proper advice and counsel the patient on the proper course of treatment to be taken. Also by employing effective over the counter (OTC counseling as the most proper means in a pharmacist/patient communication process and, accordingly, rapport building in the OTC area, the pharmacist needs to demonstrate high energy, enthusiasm, respect, empathy, know-how of sensitive intercultural issues alongside personal appearance, body language, eye contact that all together make his/her personal “signature”. Accordingly, apart from patient education, the primary objective of OTC counseling becomes to educate pharmacists on basic principles used in assisting patients in the selection of over-the-counter (OTC products, provide examples of proper communication techniques for effective patient counseling concerning the OTC products (i.e. dosage, administration technique, storage, food and beverage interaction, monitoring etc where the pharmacist plays the key role in helping patients maximize their pharmaceutical care.

  8. About the distribution of delays in G.M counters

    International Nuclear Information System (INIS)

    Picard, E.; Rogozinski, A.

    1954-01-01

    We measure, with an oscillograph method the global time that pass between the time that a particle in a determined region of the studied counter and the answer of the amplifier associated to the counter. This delay is composed of the latency time T l and the T q delay, that result from the rise time finished of the impulse and whose value depends of the sensitivity threshold of the amplifier. The selection of (cosmic) particles generating discharge in the studied counter is obtained thanks to a telescope of two meters in coincidence whose opening is limited by a group of four counters in anti-coincidence with the first. The meter is arranged so that the median plan of the telescope crosses to a variable distance d of his axial thread. The measures have been done for different securities of the distance d and of the over-voltage V s applied to the counter. The results show that the statistical distribution of the delays is more spread especially when d is bigger and V s more reduced. The average values of the observed delays vary of 7.10 -8 s for d = 0 and V s es = 200 V, to 90.10 -8 s for d = 1,9 cm and V s = 50 V. The mobility of an free electron within the gaseous mixture filling the counter under a pressure of 10 cm.Hg was found equal: (2,1 ±0,2).10 4 cm 2 .s -1 .V -1 . (author) [fr

  9. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  10. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    Science.gov (United States)

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  11. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    Directory of Open Access Journals (Sweden)

    Carola Leicht

    2017-06-01

    Full Text Available Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1 counter-stereotype salience and (2 feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208 attended to gender stereotypic (vs. counter-stereotypic content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  12. Calibration of the whole body counter at PSI

    International Nuclear Information System (INIS)

    Mayer, Sabine; Boschung, Markus; Fiechtner, Annette; Habegger, Ruedi; Meier, Kilian; Wernli, Christian

    2008-01-01

    At the Paul Scherrer Institut (PSI), measurements with the whole body counter are routinely carried out for occupationally exposed persons and occasionally for individuals of the population suspected of radioactive intake. In total about 400 measurements are performed per year. The whole body counter is based on a p-type high purity germanium (HPGe) coaxial detector mounted above a canvas chair in a shielded small room. The detector is used to detect the presence of radionuclides that emit photons with energies between 50 keV and 2 MeV. The room itself is made of iron from old railway rails to reduce the natural background radiation to 24 n Sv/h. The present paper describes the calibration of the system with the IGOR phantom. Different body sizes are realized by different standardized configurations of polyethylene bricks, in which small tubes of calibration sources can be introduced. The efficiency of the detector was determined for four phantom geometries (P1, P2, P4 and P6 simulating human bodies in sitting position of 12 kg, 24 kg, 70 kg and 110 kg, respectively. The measurements were performed serially using five different radionuclide sources ( 40 K, 60 Co, 133 Ba, 137 Cs, 152 Eu) within the phantom bricks. Based on results of the experiment, an efficiency curve for each configuration and the detection limits for relevant radionuclides were determined. For routine measurements, the efficiency curve obtained with the phantom geometry P4 was chosen. The detection limits range from 40 Bq to 1000 Bq for selected radionuclides applying a measurement time of 7 min. The proper calibration of the system, on one hand, is essential for the routine measurements at PSI. On the other hand, it serves as a benchmark for the already initiated characterisation of the system with Monte Carlo simulations. (author)

  13. DEVELOPMENT OF HETEROGENEOUS PROPORTIONAL COUNTERS FOR NEUTRON DOSIMETRY.

    Science.gov (United States)

    Forouzan, Faezeh; Waker, Anthony J

    2018-01-10

    The use of a custom-made cylindrical graphite proportional counter (Cy-GPC) along with a cylindrical tissue equivalent proportional counter (TEPC) for neutron-gamma mixed-field dosimetry has been studied in the following steps: first, the consistency of the gamma dose measurement between the Cy-TEPC and the Cy-GPC was investigated over a range of 20 keV (X-ray) to 0.661 MeV (Cs-137 gamma ray). Then, with both the counters used simultaneously, the neutron and gamma ray doses produced by a P385 Neutron Generator (Thermo Fisher Scientific) together with a Cs-137 gamma source were determined. © The Author(s) 2018. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. A semiconductor counter telescope for neutron reaction studies

    Energy Technology Data Exchange (ETDEWEB)

    Lalovic, B I; Ajdacic, V S [Institute of nuclear sciences Boris Kidric, Vinca, Beograd (Yugoslavia)

    1963-12-15

    A counter telescope consisting of two or three semiconductor counters for {delta}E/{delta}x vs. E analysis was made for studying nuclear reactions induced by 14.4 MeV neutrons. Various factors important for the telescope performance are discussed in details and some solutions for getting an optimum resolution and a low background are given. Protons, deuterons and alpha particles resulting from scattering and reactions of 14.4 MeV neutrons on deuterium, tritium, praseodymium and niobium were detected, and pulses from the counters recorded on a two-dimensional analyzer. These experiments have shown that the telescope compares favorably with other types of telescopes with regards to the upper limit of neutron flux which can be used, (DELTADELTA)x and E resolution, versatility and compactness (author)

  15. Carbon Nanotubes Counter Electrode for Dye-Sensitized Solar Cells Application

    Directory of Open Access Journals (Sweden)

    Drygała A.

    2016-06-01

    Full Text Available The influence of the carbon nanotubes counter electrode deposited on the FTO glass substrates on the structure and optoelectrical properties of dye-sensitized solar cells counter electrode (CE was analysed. Carbon materials have been applied in DSSC s in order to produce low-cost solar cells with reasonable efficiency. Platinum is a preferred material for the counter electrode because of its high conductivity and catalytic activity. However, the costs of manufacturing of the platinum counter electrode limit its use to large-scale applications in solar cells. This paper presents the results of examining the structure and properties of the studied layers, defining optical properties of conductive layers and electrical properties of dye-sensitized solar cells manufactured with the use of carbon nanotubes.

  16. Towards a Theory of Fear Management in the Counter-Terrorism Domain

    Directory of Open Access Journals (Sweden)

    Edwin Bakker

    2014-01-01

    Full Text Available Since 9/11, the state of the art in counter-terrorism research, counter-terorism measures and counter-terrorism impacts has taken off. Nevertheless, countering terrorism as a branch of fear management is still a discipline to be developed. In this Research Paper, authors Prof. Dr. Edwin Bakker and Prof. Dr. Beatrice de Graaf attempt to lessen this gap. The Paper identifies and analyses governmental approaches to managing fear in relation to terrorist incidents. It is a stocktaking approach, offering a preliminary oversight of some central aspects and pointers on the way forward when constructing and testing such a theory.

  17. Countermeasure for terrorism-new field of radiation protection

    International Nuclear Information System (INIS)

    Ye Changqing

    2003-01-01

    The workers on radiation protection have been confronted with a new task-countering terrorism. The description and level of various threats threats, the potential consequences and occurrence probability of different nuclear and radiation attack events, and the responses to these threats (crisis and consequence) are introduced at two levels. At the level of crisis management, some approaches to mitigation, the works done by International Atomic Energy Agency and the tendency in United States are also presented. At the level of consequence management, the essential practices submitted by National Council on Radiation Protection and Measurements of America are listed. Finally the domest ic progress in this area is introduced too. (authors)

  18. Counter-diffusion and -permeation of deuterium and hydrogen through metals

    Energy Technology Data Exchange (ETDEWEB)

    Kizu, Kaname; Tanabe,; Tetsuo, [Nagoya Univ. (Japan)

    1998-03-01

    The first experiments for counter-diffusion and -permeation of deuterium and hydrogen through palladium were performed. Deuterium permeation rates against D{sub 2} pressure were measured under the condition where hydrogen permeated to opposite direction by supplying H{sub 2} gas at the permeated side of D{sub 2}. It was found that not a small amount of deuterium was clearly permeated even if the deuterium pressure was much smaller than the hydrogen pressure. Deuterium permeation rate was gradually reduced by increasing the counter H permeation. The deuterium permeation rate under the counter H permeation is well represented by a simple model in which the ratio of the deuterium permeation rates with and without the counter H permeation was proportional to the fractional concentration of deuterium in the bulk. As increasing the hydrogen counter flow, however, the deuterium permeation rate deviates from the model. This means that adsorption (absorption) of D{sub 2} from gas phase is inhibited and surface recombination of deuterium is blocked by hydrogen. (author)

  19. The effect of counter-trading on competition in electricity markets

    International Nuclear Information System (INIS)

    Dijk, Justin; Willems, Bert

    2011-01-01

    In a competitive electricity market, nodal pricing is the most efficient way to manage congestion. Counter-trading is inefficient as it gives the wrong long term signals for entry and exit of power plants. However, in a non-competitive market, additional entry will improve the competitiveness of the market, and will increase social benefit by reducing price-cost margins. This paper studies whether the potential pro-competitive entry effects could make counter-trading more efficient than nodal pricing. We find that this is unlikely to be the case, and expect counter-trading to have a negative effect on overall welfare. The potential benefits of additional competition (more competitive prices and lower production cost) do not outweigh the distortions (additional investment cost for the entrant, and socialization of the congestion cost to final consumers). - Research highlights: → 'Counter-trading' and 'nodal pricing' manage congestion in electric grids. → Nodal pricing gives superior locational prices. → Counter-trading induces extra investments in regions with a production surplus. → Extra investments improve competition, but are expected to be socially inefficient.

  20. Counter terms for low momentum nucleon-nucleon interactions

    International Nuclear Information System (INIS)

    Holt, Jason D.; Kuo, T.T.S.; Brown, G.E.; Bogner, Scott K.

    2004-01-01

    There is much current interest in treating low energy nuclear physics using the renormalization group (RG) and effective field theory (EFT). Inspired by this RG-EFT approach, we study a low-momentum nucleon-nucleon (NN) interaction, V low-k , obtained by integrating out the fast modes down to the scale Λ∼2 fm -1 . Since NN experiments can only determine the effective interaction in this low momentum region, our chief purpose is to find such an interaction for complex nuclei whose typical momenta lie below this scale. In this paper we find that V low-k can be highly satisfactorily accounted for by the counter terms corresponding to a short range effective interaction. The coefficients C n of the power series expansion ΣC n q n for the counter terms have been accurately determined, and results derived from several meson-exchange NN interaction models are compared. The counter terms are found to be important only for the S, P and D partial waves. Scaling behavior of the counter terms is studied. Finally we discuss the use of these methods for computing shell model matrix elements

  1. The extended range neutron rem counter LINUS: overview and latest developments

    International Nuclear Information System (INIS)

    Birattari, C.; Rancati, T.; Esposito, A.; Pelliccioni, M.; Ferrari, A.; Silari, M.

    1997-01-01

    The 'history' of the extended range neutron rem counter LINUS, since its first conception in 1990 is reviewed, along with the latest developments. These include the calibration of the initially cylindrical version with nearly monoenergetic neutrons in the energy range 34-66 MeV, a detailed evaluation of the anisotropy of its response function, the construction and calibration of an improved spherical version, and recent measurements in reference high energy stray radiation fields. The instrument can now be considered as being fully characterized. Similar monitors built by other laboratories following the present design have confirmed its performances. The instrument is now in semi-routine use at a number of particle accelerator facilities and is one of several devices used on-board of aircrafts for assessing the exposure to cosmic rays at commercial flight altitudes. (author)

  2. Controlling electron quantum paths for generation of circularly polarized high-order harmonics by H2+ subject to tailored (ω , 2 ω ) counter-rotating laser fields

    Science.gov (United States)

    Heslar, John; Telnov, Dmitry A.; Chu, Shih-I.

    2018-04-01

    Recently, studies of high-order harmonics (HHG) from atoms driven by bichromatic counter-rotating circularly polarized laser fields as a source of coherent circularly polarized extreme ultraviolet (XUV) and soft-x-ray beams in a tabletop-scale setup have received considerable attention. Here, we demonstrate the ability to control the electron recollisions giving three returns per one cycle of the fundamental frequency ω by using tailored bichromatic (ω , 2 ω ) counter-rotating circularly polarized laser fields with a molecular target. The full control of the electronic pathway is first analyzed by a classical trajectory analysis and then extended to a detailed quantum study of H2+ molecules in bichromatic (ω , 2 ω ) counter-rotating circularly polarized laser fields. The radiation spectrum contains doublets of left- and right-circularly polarized harmonics in the XUV ranges. We study in detail the below-, near-, and above-threshold harmonic regions and describe how excited-state resonances alter the ellipticity and phase of the generated harmonic peaks.

  3. Analysis of counter-rotating wind turbines

    DEFF Research Database (Denmark)

    Shen, Wen Zhong; Zakkam, Vinod Arun Kumar; Sørensen, Jens Nørkær

    2007-01-01

    This paper presents a study on the performance of a wind turbine with two counter-rotating (CRWT) rotors. The characteristics of the two counter-rotating rotors are on a 3-bladed Nordtank 500 kW rotor. The analysis has been carried out by using an Actuator Line technique implemented in the Navier......-Stokes code EllipSys3D. The analysis shows that the Annual Energy Production can be increased to about 43.5 %, as compared to a wind turbine with a single rotor. In order to determine the optimal settings of the CRWT turbine, parameters such as distance between two rotors and rotational speed have been...

  4. Calibration of nuclear medicine gamma counters

    International Nuclear Information System (INIS)

    Orlic, M.; Spasic-Jokic, V.; Jovanovic, M.; Vranjes, S. . E-mail address of corresponding author: morlic@vin.bg.ac.yu; Orlic, M.)

    2005-01-01

    In this paper the practical problem of nuclear medicine gamma counters calibration has been solved by using dose calibrators CRC-15R with standard error ±5%. The samples from technetium generators have been measured both by dose calibrators CRC-15R and gamma counter ICN Gamma 3.33 taking into account decay correction. Only the linear part of the curve has practical meaning. The advantage of this procedure satisfies the requirements from international standards: the calibration of sources used for medical exposure be traceable to a standard dosimetry laboratory and radiopharmaceuticals for nuclear medicine procedures be calibrated in terms of activity of the radiopharmaceutical to be administered. (author)

  5. Neutron coincidence counter for MOX fuel pins in storage trays: users' manual

    International Nuclear Information System (INIS)

    Cowder, L.; Menlove, H.

    1982-08-01

    The neutron coincidence counter for measurement of mixed-oxide fuel pins in storage trays is described. The special detector head has been designed so that the detectors, high-voltage junction boxes, and electronics are interchangeable with those of the high-level neutron coincidence counter system. This manual describes the system components and the operation and maintenance of the counter. The counter was developed at Los Alamos National Laboratory for in-plant inspection applications by the International Atomic Energy Agency

  6. Counter-terrorism strategies in Indonesia, Algeria and Saudi Arabia

    NARCIS (Netherlands)

    Meijer, R.; Hasan, Noorhaidi; Hendriks, B.; Janssen, F.

    2012-01-01

    This report is the result of a year-long study, conducted from March 2010 to March 2011, of the counter-terrorist strategies of three countries: Indonesia, Algeria and Saudi Arabia. The aim of this study was to acquire insight into the counter-terrorist strategies of these countries, to analyse

  7. Design and Implementation of MOD-6 Synchronous Counter using VHDL

    Directory of Open Access Journals (Sweden)

    P. Y. Dibal

    2013-08-01

    Full Text Available This paper deals with the design of a MOD-6 synchronous counter using VHDL (VHSIC Hardware Description Language. The VHSIC stands for Very High Speed Integrated Circuit. Using this approach, the behaviour of the counter is the most important aspect of the design. In the first section, the paper introduced counters in general, and their areas of specialization, like frequency synthesizers. The synchronous counter was then introduced, stating the behaviour of the flip-flops that make the counter. The modulus of a counter was defined. In the second section, the Xilinx ISE (Integrated Simulation Environment and the ISIM (Integrated Simulator were presented and briefly described with their respective snapshots. The structure of a typical VHDL code was presented, which included LIBRARY, ENTITY, and ARCHITECTURE. Each of these structures was then briefly described. The main work in this paper was then presented. The count sequence steps were stated as . VHDL was used to model the counter to count through six steps, outputting count values according to desired steps. The hardware implementation of the design was presented, where the implementation process was described, with a supporting diagram, followed by the floor-planning technique, in which the PORTS described in the VHDL design were assigned to the physical pins of the XC3S1000 FPGA (Field Programmable Gate Array chip. The final steps of the hardware implementation process were then presented. These include bitstream generation and download to target device. The third section of the paper presented the results obtained. Simulation/timing results of the design were presented, showing the output of the counter at each state with respect to the clock signal. The result of the synthesis of the design was presented, which showed the FPGA area with the exact location of the pins on the FPGA chip. Finally, the fourth section presented the conclusion arrived at, in respect of the design that was carried

  8. Radiation detectors for reactors

    International Nuclear Information System (INIS)

    Balagi, V.

    2005-01-01

    Detection and measurement of radiation plays a vital role in nuclear reactors from the point of view of control and safety, personnel protection and process control applications. Various types of radiation are measured over a wide range of intensity. Consequently a variety of detectors find use in nuclear reactors. Some of these devices have been developed in Electronics Division. They include gas-filled detectors such as 10 B-lined proportional counters and chambers, fission detectors and BF 3 counters are used for the measurement of neutron flux both for reactor control and safety, process control as well as health physics instrumentation. In-core neutron flux instrumentation employs the use detectors such as miniature fission detectors and self-powered detectors. In this development effort, several indigenous materials, technologies and innovations have been employed to suit the specific requirement of nuclear reactor applications. This has particular significance in view of the fact that several new types of reactors such as P-4, PWR and AHWR critical facilities, FBTR, PFBR as well as the refurbishment of old units like CIRUS are being developed. The development work has sought to overcome some difficulties associated with the non-availability of isotopically enriched neutron-sensing materials, achieving all-welded construction etc. The present paper describes some of these innovations and performance results. (author)

  9. Prescription Drugs, Over-the-Counter Drugs, Supplements and Herbal Products

    Science.gov (United States)

    ... at risk? Zika virus and pregnancy Folic acid Medicine safety and pregnancy Birth defects prevention Learn how ... the-counter drugs, supplements and herbal products Prescription drugs, over-the-counter drugs, supplements and herbal products ...

  10. Whole body counters: types, performance and uses

    International Nuclear Information System (INIS)

    Jales, R.L.C.

    1983-01-01

    The present monograph deals with Whole Counters, since its definition, evolution, performance, clinical indications and results. Scintillation crystals detection systems were described as well as scintillant solutions, plastic scintillations, and gaseous detectors, including its interplay forms and basal characteristics. Geometric arrangements of standard chair, arc and hammock, arrangements with scintillant solutions and plastic scintillations, as well as special geometric arrangements were equally commented. Clinic and experimental studies were also dealt with Whole Body Counters, giving examples with potassium, iron vitamin B 12 and albumin. (author)

  11. Alpha–beta monitoring system based on pair of simultaneous Multi-Wire Proportional Counters

    Energy Technology Data Exchange (ETDEWEB)

    Wengrowicz, U.; Amidan, D. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel); NRC-Negev, P.O. Box 9001, Beer-Sheva 84190 (Israel); Orion, I. [Department of Nuclear Engineering, Ben Gurion University of the Negev, Beer-Sheva 84105 (Israel)

    2016-08-11

    A new approach for a simultaneous alpha–beta Multi-wire Proportional Counter (MWPC) is presented. The popular approach for alpha–beta monitoring systems consists of a large area MWPC using noble gas flow such as Argon Methane. This method of measurement is effective but requires large-scale and expensive maintenance due to the needs of gas flow control and periodic replacements. In this work, a pair of simultaneous MWPCs for alpha–beta measuring is presented. The developed detector consists of a sealed gas MWPC sensor for beta particles, behind a free air alpha sensor. This approach allows effective simultaneous detection and discrimination of both alpha and beta radiation without the maintenance cost noble gas flow required for unsealed detectors.

  12. A gaseous scintillation counter filled with He3 for neutron spectrometry

    International Nuclear Information System (INIS)

    Baldin, S.A.; Matveev, V.V.

    1962-01-01

    The paper describes a gas plant and gaseous scintillation counter, and gives the results of experiments on the recording and spectrometry of neutron beams using a gaseous scintillation counter filled with a mixture of 10% xenene and 90% helium-3 at an overall pressure of 20 ata. Data are given on the design of the gas plant, which makes it possible to operate the counter continuously over long periods of time, as well as providing the required gas mixtures at overall pressures of up to 60 atm and ensuring constant freedom of the gas from contamination. In addition, the paper presents the results of research on the counter's energy resolution and linearity at different energy levels and indicates its efficiency in gamma fields of intensity up to 3 r/h; the possibility of extending the working energy-range of gaseous scintillation counters filled with helium-3 is also considered. (author) [fr

  13. A miniature spark counter for public communication and education

    International Nuclear Information System (INIS)

    Mao, C.H.; Weng, P.S.

    1987-01-01

    The fabrication of a miniature spark counter for public communication and education using naturally occurring radon as a radioactive source without involving any man-made radioactivity is described. The battery-powered miniature spark counter weighs 2.07 kg with a volume of 4.844 x 10/sup -4/ m/sup 3/. The circuitry consists of seven major components: timer, high-voltage power supply, attenuator, noninverting amplifier, low-pass filter, one-shot generator, and counter. Cellulose nitrate films irradiated with alpha particles from radon emanating from soil were etched and counted. The visible sparks during counting are rather heuristic, which can be used to demonstrate naturally occurring radioactivity in classrooms or showplaces

  14. Hardware support for collecting performance counters directly to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  15. A test of planar spark counters at the PEP storage ring

    International Nuclear Information System (INIS)

    Atwood, W.B.; Bowden, G.B.; Bonneaud, G.R.; Klem, D.E.; Ogawa, A.; Pestov, Yu.N.; Pitthan, R.; Sugahara, R.

    1983-01-01

    A test of planar spar counters (PSCs) at the PEP electron-positron storage ring showed the following. PSCs can be used under harsh experimental conditions without long term degradation of resolution. On-line time-of-flight resolutions were below 200 ps, coordinate resolutions better than 4 mm, both limited to these values by the resistivity of the semiconducting glass and the electronics used. The best single counter time resolution under realistic conditions at the storage ring was 76 ps. Pulse height was a good indicator of the number of particles striking a counter. Subsequent measurements using cosmis rays gave a single counter time resolution of 50 ps. (orig.)

  16. A proportional counter for efficient backscatter Moessbauer effect spectroscopy

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Cudny, W.; Holnicka, J.; Walentek, J.

    1979-01-01

    The authors present a novel gas-tight proportional counter with flat beryllium windows for backscatter Moessbauer spectroscopy. The krypton-filled counter has a geometry that approaches 2π and a resolution of 12% fwhm for the 14.4 keV line of 57 Fe, and is easy to manufacture. (Auth.)

  17. Environmental radiation monitoring around the nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Woo; Choi, Geun Sik and others

    2001-02-01

    Environmental Radiation Monitoring was carried out with measurement of environment. Radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul Research Reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul Research Reactor are the follows : The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost same level compared with the past years. Gross {alpha}, {beta} radioactivity in environmental samples showed a environmental level. {gamma}-radionuclides in water samples were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul Research Reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by {gamma}-spectrometry.

  18. Environmental radiation monitoring around the nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Chang Woo; Choi, Young Ho

    2000-02-01

    Environmental radiation monitoring was carried out with measurement of environment radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul Research Reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul Research Reactor are the follows: The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost some level compared with the past years. Gross α, β radioactivity in environmental samples showed a environmental level. γ-radionuclides in water sample were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul Research Reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by γ-spectrometry. (author)

  19. Environmental radiation monitoring around the nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Woo; Choi, Young Ho

    2000-02-01

    Environmental radiation monitoring was carried out with measurement of environment radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul Research Reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul Research Reactor are the follows: The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost some level compared with the past years. Gross {alpha}, {beta} radioactivity in environmental samples showed a environmental level. {gamma}-radionuclides in water sample were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul Research Reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by {gamma}-spectrometry. (author)

  20. Environmental radiation monitoring around the nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chang Woo; Choi, Young Ho; Lee, M.H. [and others

    1999-02-01

    Environmental radiation monitoring was carried out with measurement of environment radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul research reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul research reactor are the follows : The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost same level compared with the past years. Gross {alpha}, {beta} radioactivity in environmental samples showed a environmental level. {gamma}-radionuclides in water samples were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul research reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by {gamma}-spectrometry. (author). 3 refs., 50 tabs., 12 figs.

  1. Environmental radiation monitoring around the nuclear facilities

    International Nuclear Information System (INIS)

    Lee, Chang Woo; Choi, Geun Sik and others

    2001-02-01

    Environmental Radiation Monitoring was carried out with measurement of environment. Radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul Research Reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul Research Reactor are the follows : The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost same level compared with the past years. Gross α, β radioactivity in environmental samples showed a environmental level. γ-radionuclides in water samples were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul Research Reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by γ-spectrometry

  2. Environmental radiation monitoring around the research reactors

    International Nuclear Information System (INIS)

    Lee, Chang Woo; Lee, Hyun Duk; Kim, Sam Rang; Choi, Yong Ho; Kim, Jeong Moo; Lee, Myeon Joo; Lee, Myeong Ho; Hong, Kwang Hee; Lim, Moon Ho; Lee, Won Yoon; Park, Do Won; Choi, Sang Do

    1993-04-01

    Environmental radiation monitoring was carried out measurement of environmental radiation and environmental radioactivity analysis around KAERI nuclear facilities and Seoul research reactor. The results of environmental radiation monitoring around KAERI nuclear facilities and Seoul research reactor are the follows : The average level of environmental radiation dose measured by NaI scintillation counter and accumulated radiation dose by TLD was almost same level compared with the past years. Gross α, β radioactivity in environmental sample was not found abnormal data. γ-radionuclides in water samples were not detected. But only radionuclide K-40, which is natural radionuclide, was detected in the all samples and Cs-137 was detected in the surface soil and discharge sediment. The average level of environmental radiation dose around Seoul research reactor was almost same level compared with the past years, and Be-7 and Cs-137 were detected in some surface soil and discharge sediment by γ-spectrometry. (Author)

  3. 35 years of existence of whole-body counter in the Czech Republic - experiences and prospects

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, L.; Cespirova, I.

    1998-01-01

    A whole-body counter was built up in the Czech Republic in 1962, this at the then Institute of the Hygiene of Labour and Occupational Diseases. The shielding was made of steel plates taken from Tiger tanks which remained in the country as aftermath of World War II. The detecting and evaluating parts of the counter were upgraded gradually. The original 4 scintillator detectors (10.16 cm x 12.7 cm in size) were replaced with an HPGe semiconductor detector exhibiting a roughly fifty-fold better resolution, owing to which radionuclide activities can be determined in complex matrices. Currently, the whole-body counter is equipped with a high-purity Ge detector displaying a relative efficiency of 120%, special detectors for low-energy gamma radiation, so-called LEGe detectors which are employed during the determination of radionuclides in the individual organs. The facility is applied to the monitoring of internal contamination in persons handling unsealed sources, monitoring in cases of suspect accidents associated with internal contamination of humans, as well as to the determination of internal contamination in epidemiological studies. In the past, a group of persons contaminated with radioactive fluorescent dyes which contained 226 Ra and 90 Sr, and a group of patients with applied thorotrast were also examined. Currently, methods which are under development are aimed at the determination of 210 Pb in the skulls of people who have been exposed to elevated radon concentrations in dwellings for a long time, and the determination of 241 Am in human bodies and their individual organs

  4. Radioactivity in food crops from high background radiation area in southwest area

    International Nuclear Information System (INIS)

    Shanthi, G.; Maniyan, C.G.; Allan Gnana Raj, G.; Thampi Thanka Kumaran, J.

    2009-01-01

    The study was carried out to evaluate radioactive concentration in food crops grown in naturally high-background radiation areas in southwest India. Seventeen varieties of food crops were collected from different parts of Kanyakumari district. The gross alpha and beta activities of the collected samples were measured using alpha scintillation counter and low beta counter respectively. The alpha activity was maximum in tapioca (497± 72 Bq kg -1 ) and the beta activity was maximum in paddy grain (10,946±583 Bq kg -1 ). The gamma activity of the food samples was studied by measuring the activity concentration of the radionuclides ( 226 Ra, 228 Th, 238 U, 40 K) in the food crops. The radioactivity content of the food crops from high-background radiation area was higher when compared to similar samples collected from low-background radiation area. The daily radionuclide intake from the food crops grown and consumed by the public was 127.696 Bq and daily internal dose resulting from ingestion of radionuclides in food was 2.34 μSv. (author)

  5. Body counter

    International Nuclear Information System (INIS)

    Koeppe, P.

    1975-01-01

    The paper gives a survey on some applications of the whole body counter in clinical practice and a critical study of its application as a routine testing method. Remarks on the necessary precautions are followed by a more detailed discussion of the determination of the natural potassium content, the iron metabolism, the vitamin B12 test, investigations of the metabolism of the bone using 47 Ca and 85 Sr, investigations with iodine and iodine-labelled substances, clearance investigations (in particular the 51 Cr EDTA clearance test), as well as the possibilities of neutron activation in vivo. (ORU/AK) [de

  6. Discharge quenching circuit for counters

    International Nuclear Information System (INIS)

    Karasik, A.S.

    1982-01-01

    A circuit for quenching discharges in gas-discharge detectors with working voltage of 3-5 kV based on transistors operating in the avalanche mode is described. The quenching circuit consists of a coordinating emitter follower, amplifier-shaper for avalanche key cascade control which changes potential on the counter electrodes and a shaper of discharge quenching duration. The emitter follower is assembled according to a widely used flowsheet with two transistors. The circuit permits to obtain a rectangular quenching pulse with front of 100 ns and an amplitude of up to 3.2 kV at duration of 500 μm-8 ms. Application of the quenching circuit described permits to obtain countering characteristics with the slope less than or equal to 0.02%/V and plateau extent greater than or equal to 300 V [ru

  7. The study of the influence of helium on the counter's measurement properties

    International Nuclear Information System (INIS)

    Guan Rui; Weng Kuiping; Ren Xingbi

    2009-04-01

    In measurement of tritium by the proportional counter, methane is usually used as counter gas. Gas samples have been made with helium and methane in the proportion of concentration and measured to study the influence of helium on the counter's measurement properties. Then gas sample with tritium and helium has been measured, and the result is according with anticipation. The experiment has showed that the plateau curve of counter could be changed by helium, but the influence could be ignored when helium concentration less 10%. (authors)

  8. Dual-chamber/dual-anode proportional counter incorporating an intervening thin-foil solid neutron converter

    International Nuclear Information System (INIS)

    Boatner, Lynn A.; Neal, John S.; Blackston, Matthew A.; Kolopus, James A.; Ramey, Joanne O.

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6 LiF or 10 B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases—including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected—rather than having half of the products absorbed in the wall of a conventional tube-type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimum neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6 LiF-converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6 LiF and 10 B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.

  9. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    International Nuclear Information System (INIS)

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  10. Counter-transference reactions contributing to completed suicide.

    Science.gov (United States)

    Modestin, J

    1987-12-01

    Counter-transference reactions are frequently elicited while treating suicidal patients and they may contribute to the patient's committing suicide. Therapeutic constellations including the failure of the therapist to (1) cope with the patient's aggressiveness, (2) tolerate the patient's dependency, (3) handle the erotic transference adequately and (4) preserve loyalty towards the patient; they have all been identified as being responsible for a therapeutic impasse with fatal consequences. Knowledge of the therapeutic constellations especially prone to facilitate negative counter-transference reactions may help the therapist to master them effectively.

  11. Interaction between counter-streaming ion-acoustic solitons and the Langmuir waves

    International Nuclear Information System (INIS)

    Basovich, A.Ya.; Gromov, E.M.; Talanov, V.I.

    1984-01-01

    The interaction between strong counter-streaming ion-acoustic solitons and the Langmuir waves is considered. At first the Langmuir waves spectrum transformation by counter-streaming ion-acoustic solutions of a preset amplitude e has been found. An increase in the frequency and number of the Langmuir waves due to the Doppler effect in the course of multiple reflection from the f front soliton slope has been determined and the wave number range in which the confinement of the Langmuir waves by counter-streaning solitons is possible has s been found. It is shown that the time of the Langmuir wave transformation into the short-wave region under the effect of the counter-streaming soliton may y be short as compared with the time of the Langmuir wave diffusion into the Landau damping region under the effect of random fields of ion-acoustic waves. In the adiabatic fpproximation changes in the counter-streaming ion acoustic parameters of solitons owing to the Langmuir waves have been

  12. Solidarity and Recognition: Geographies of Counter-globalism

    Directory of Open Access Journals (Sweden)

    James Goodman

    2006-02-01

    Full Text Available Globalism is a contested concept, but perhaps best understood as a spatial strategy, which disempowers those unable to transcend the fixity of place and social context. Under globalism fluidity becomes a key source of power, enabling the powerful to liquefy assets, to disembed, and thereby displace, political, social or ecological impacts. The infrastructures of globalism enable the disembodied extension of power across territory, to the extent that one model, universally applicable for all societies, is positioned as supreme. The only possible challenge to globalism perhaps, is through a similarly disembedded counter-movement, that mirrors the global reach and power of mainstream globalism. The praxis of counter-globalist movements suggests a different tendency, one that centres on the assertion of particularity against universality. Expressed in the legitimacy of ‘many worlds’ against ‘one world’ globalism, such resistance centres on exposing the material effects and foregrounding concrete and material experiences of globalism. Movements mobilise against the disembodied logic of globalism on the basis of co-presence and inter-subjectivity, and are embedded in relational concepts of selfhood. They are often intensely embodied and are radically emplaced through militant localism and trans-local dialogue. Counter-globalism thus does not seek to defeat geography; rather it embraces it, as the starting-point of mobilisation. The starting point of this article is thus to analyse globalism as a spatial strategy, a strategy of displacement grounded in material power. Globalism thus signifies the capacity to exploit and dominate at distance, from the sanctity of corporate boardrooms, military briefings and media cutting rooms. The claim is to universal market, military and normative power, but the impact is of extended and deepened division. Centres of power appear more as islands, or enclaves, defined against the backwash effects of counter

  13. Development of radiation protection and measurement technology -A study on the radiation and environmental safety-

    International Nuclear Information System (INIS)

    Chang, Si Young; Seo, Kyeong Won; Yoon, Seok Cheol; Lee, Tae Yeong; Kim, Bong Hwan; Chung, Deok Yeon; Lee, Ki Chang; Kim, Jong Soo; Yoon, Yeo Chang; Kim, Jang Ryeol; Lee, Sang Yoon

    1994-07-01

    Reference radiation fields which can meet the national and international standard and criteria such as the ANSI N13.11 have been designed, produced and evaluated to maintain the national traceability and reliability of the radiation measurement and to provide precise calibration of the various radiation measuring instruments as well as standard irradiation of the personal dosimeters for the performance evaluation. Existing dose calculation algorithm has been improved to correctly evaluate the shallow dose from the β(Ti-204) + γ(Cs-137) mixed radiation exposure by applying the TLD response correction function newly derived in this study. A mathematical algorithm to calculate the internal dose from inhalation of the uranium isotopes has been developed on the basis of the ICRP-30 respiratory tract model. Detailed performance analysis of the KAERI lung counter has been carried out to participate in the intercomparison of lung dosimetry. A preliminary and basic study on the quantitative method of optimal dose reduction based on the ALARA concept has been performed to technically support and strengthen the national radiation protection infrastructure. (Author)

  14. Transparent platinum counter electrode for efficient semi-transparent dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Iefanova, Anastasiia; Nepal, Jeevan; Poudel, Prashant; Davoux, Daren; Gautam, Umesh [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Mallam, Venkataiah [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Qiao, Qiquan [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States); Logue, Brian [Chemistry and Biochemistry Department, South Dakota State University, Brookings, SD 57006 (United States); Baroughi, Mahdi Farrokh, E-mail: m.farrokhbaroughi@sdstate.edu [Electrical Engineering and Computer Science Department, South Dakota State University, Brookings, SD 57006 (United States)

    2014-07-01

    A method for fabrication of highly transparent platinum counter electrodes (CEs) has been developed based on spray coating of Pt nanoparticles (NPs) on hot substrates. This method leads to 86% reduction in Pt consumption reducing the Pt cost per peak watt of counter electrode from $0.79/Wp down to $0.11/Wp compared to the conventional Pt counter electrodes made by sputter deposition. The simplicity and low cost of this method provide a basis for an up-scalable fabrication process. The Pt NP layer is over 88% transparent, leading to overall transparency of 80% when incorporated with indium tin oxide/glass substrates for functional counter electrodes. This counter electrode exhibits a large surface area and high catalytic activity, comparable to that of the conventional opaque CEs. Semi-transparent dye-sensitized solar cells fabricated based on this counter electrode showed 6.17% power conversion efficiency. - Highlights: • Counter electrode (CE) prepared by spraying nanoparticle (NP) Pt on hot substrate. • Low cost and scalable fabrication process of CE. • The spray deposited CE uses 10 times less Pt compared to the sputtering method. • The CE is 80% transparent and exhibits a large surface and high catalytic activity. • A semitransparent dye-sensitized solar cell with Pt NP CE was 6.17% efficient.

  15. SGR-76 gamma radiation level indicator

    International Nuclear Information System (INIS)

    Chubinskij-Nadezhdin, I.V.

    1978-01-01

    The design of a gamma-radiation level indicator is described; the instrument is part of a mobile radiometric laboratory (MRL). The design of the instrument permits gamma-radiation dose rates recording at 0.2-200 R/hr, and signals on gamma-background levels. The instrument has two separate threshold levels of signalling actuation. The light signalling at the first level is precautionary, and the sound signalling at the second level indicates the necessity of taking a decision as to whether or not the MRL can remain in the gamma-radiation field. Halogenic counters operating in a current mode are used as detectors. The basic error in recording the dose rate amounts to +-25%. Overall dimensions of the instrument 150x280x100 mm; weight less than 2.5 kg

  16. Monte Carlo simulation of neutron counters for safeguards applications

    International Nuclear Information System (INIS)

    Looman, Marc; Peerani, Paolo; Tagziria, Hamid

    2009-01-01

    MCNP-PTA is a new Monte Carlo code for the simulation of neutron counters for nuclear safeguards applications developed at the Joint Research Centre (JRC) in Ispra (Italy). After some preliminary considerations outlining the general aspects involved in the computational modelling of neutron counters, this paper describes the specific details and approximations which make up the basis of the model implemented in the code. One of the major improvements allowed by the use of Monte Carlo simulation is a considerable reduction in both the experimental work and in the reference materials required for the calibration of the instruments. This new approach to the calibration of counters using Monte Carlo simulation techniques is also discussed.

  17. Measurements of Radon Concentration in Yemen Using Spark Counter

    International Nuclear Information System (INIS)

    Arafa, W.; Abou-Leila, M.; Hafiz, M.E.; Al-Glal, N.

    2011-01-01

    Spark counter has been designed and realized and the optimum applied voltage was found to be 600 V. Excellent consistent agreements was observed between counted number of tracks by spark counter and reading by optical microscope. Radon concentration in some houses in Sana'a and Hodeidah cities in Yemen had been performed using LR-115 SSNTD and spark counter system. The average radon concentration in both cities was far lower the alert value. The results showed that radon concentration in the metropolitan area Sana'a was higher than that in Hodeidah city. Also, it was observed that old residential houses had higher levels of radon concentrations have compared to newly built houses in the metropolitan area Sana'a

  18. High-level neutron coincidence counter (HLNCC): users' manual

    International Nuclear Information System (INIS)

    Krick, M.S.; Menlove, H.O.

    1979-06-01

    This manual describes the portable High-Level Neutron Coincidence Counter (HLNCC) developed at the Los Alamos Scientific Laboratory (LASL) for the assay of plutonium, particularly by inspectors of the International Atomic Energy Agency (IAEA). The counter is designed for the measurement of the effective 240 Pu mass in plutonium samples which may have a high plutonium content. The following topics are discussed: principle of operation, description of the system, operating procedures, and applications

  19. A comprehensive test specification for pulse fission counters

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D L [Control and Instrumentation Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1962-02-15

    The following test specification is based on the memorandum AERE - M 728 which it now replaces It contains a standard acceptance test procedure for the many U.K.A.E.A, designed pulse fission counters now commercially available. This test specification may be used for any pulse fission counter provided a specification sheet as shown in Appendix 3 is supplied to the contractor quoting this report and including specified values for the measured quantities. (author)

  20. Design of instrument for monitoring nuclear radiation and baneful gas

    International Nuclear Information System (INIS)

    Xiong Jianping; Chen Jun; Zhu Wenkai

    2006-01-01

    Counters and ionization chambers are applied to sensors, and microprocessor based on ARM IP is applied to center controller in the instrument. It is achieved to monitor nuclear radiation and baneful gas in an instrument. The instrument is capable of LCD displaying, menu operating and speech alarming. (authors)

  1. Counter diffusion of zinc and iron in alluvial soil

    International Nuclear Information System (INIS)

    Rattan, R.K.; Deb, D.L.

    1980-01-01

    Half cell technique showed that an increase in moisture tension and CaCO 3 content caused reduction in the counter diffusion coefficients of zinc and iron in an alluvial soil. Increases in bulk density, ambient temperature and concentration of synthetic chelating agents e.g. EDTA and DTPA increased the counter diffusion coefficients of both zinc and iron. (author)

  2. Activated graphene nanoplatelets as a counter electrode for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Jiawei [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Zhou, Zhengping; Qiao, Qiquan, E-mail: qiquan.qiao@sdstate.edu [Center for Advanced Photovoltaics, Department of Electrical Engineering, South Dakota State University, Brookings, South Dakota 57007 (United States); Sumathy, K. [Department of Mechanical Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States); Yang, Huojun [Department of Construction Management and Engineering, North Dakota State University, Fargo, North Dakota 58102 (United States)

    2016-04-07

    Activated graphene nanoplatelets (aGNPs) prepared by a hydrothermal method using KOH as activating agent were used as counter electrode for high efficiency dye-sensitized solar cells (DSSCs). After the KOH activation, the scanning electron microscopy image shows that aGNPs demonstrate a more curled, rough, and porous morphology which could contain both micro- and mesopores. The KOH activation changed the stacked layers of GNPs to a more crumpled and curved morphology. The microstructure of large pores significantly increased the electrode surface area and roughness, leading to the high electrocatalytic activity for triiodide reduction at the counter electrode. The DSSCs fabricated using aGNP as counter electrodes were tested under standard AM 1.5 illumination with an intensity of 91.5 mW/cm{sup 2}. The device achieved an overall power conversion efficiency of 7.7%, which is comparable to the conventional platinum counter electrode (8%). Therefore, the low cost and high performance aGNP based counter electrode is a promising alternative to conventional Pt counter electrode in DSSCs.

  3. Design of an extended range long counter using super Monte Carlo simulation

    International Nuclear Information System (INIS)

    Mazunga, Mohamed; Li, Taosheng; Li, Yanan; Hong, Bing; Wang, Yongfeng; Ji, Xiang

    2017-01-01

    We have designed an extended range neutron long counter on the basis of work optimized using SuperMC code. The problem of the existing traditional long counters is that their response function falls rapidly above 5 MeV. We proposed a new designed by adding two layers of converter material inside the polyethylene moderator. The relatively low density chromium and high density lead metals convert high energy neutron by (n, xn) spallation reaction. This produces more neutrons of lower energies, which have higher probability of being detected by thermal 3 He-counter. The response function at lower neutron energies was improved by inserting small polyethylene cylinder in front of 3 He counter. In this design we achieved to extent the flat response function of the long counter from few keV up to 150 MeV. The total fluctuation of response curve is less than ±9% over the entire energy range. The designed long counter is suitable to be used as neutron monitor for monitoring neutron fluence at high-energy neutron source. (authors)

  4. Detection of neutrons of intermediate energy using 10B, enclosed in a coaxial Ge(Li) counter

    International Nuclear Information System (INIS)

    Huck, A.; Klotz, G.; Walter, G.

    1976-01-01

    A neutron detector operating in the energy range 1keV to roughly 1MeV with a time response that is fast enough to be used in time-of-flight experiments, has been designed and built. The neutron is absorbed in boron-10, placed inside a coaxial Ge(Li) counter. Efficient detection of the 478keV line from 7 Li, resulting from 10 B(n,α) 7 Li*, is realized. At the same time, the measurement of accompanying γ radiations, emitted by the neutron source, can be performed. Examples of results, obtained using (p,nγ) reactions, are given [fr

  5. Countering 21st Century Threats

    DEFF Research Database (Denmark)

    Scharling Pedersen, Peter; Pillai, Chad M.; Hun, Lee Jae

    2015-01-01

    ), Counter-Terrorism (CT), and Security and Stability Operations (SSO). • Establishing a construct that allows a strategic Whole-of-Government capacity for operations coordinated by joint interagency task forces. • Continue to developing the Global SOF network. • Increased intelligence sharing in areas...

  6. 78 FR 57623 - TRICARE Over-the-Counter Drug Demonstration Project

    Science.gov (United States)

    2013-09-19

    ... B One-Step (levonorgestrel) emergency contraceptive as an over-the-counter product ``for all women...-Counter Plan B One-Step Emergency Contraceptive (levonorgestrel). (2) OTC availability of Plan B One-Step Emergency Contraceptive (levonorgestrel) through the demonstration project will be at retail dispensing...

  7. Replacement between conformity and counter-conformity in consumption decisions.

    Science.gov (United States)

    Chou, Ting-Jui; Chang, En-Chung; Dai, Qi; Wong, Veronica

    2013-02-01

    This study assessed, in a Chinese context, how self-esteem interacts with perceived similarity and uniqueness to yield cognitive dissonance, and whether the dissonance leads to self-reported conformity or counter-conformity behavior. Participants were 408 respondents from 4 major Chinese cities (M age = 33.0 yr., SD = 4.3; 48% men). Self-perceptions of uniqueness, similarity, cognitive dissonance, self-esteem and need to behave in conformity or counter-conformity were measured. A theoretical model was assessed in four situations, relating the ratings of self-esteem and perceived similarity/uniqueness to the way other people at a wedding were dressed, and the resultant cognitive dissonance and conformity/ counter-conformity behavior. Regardless of high or low self-esteem, all participants reported cognitive dissonance when they were told that they were dressed extremely similarly to or extremely differently from the other people attending the wedding. However, the conforming/counter-conforming strategies used by participants to resolve the cognitive dissonance differed. When encountering dissonance induced by the perceived extreme uniqueness of dress, participants with low self-esteem tended to say they would dress next time so as to conform with the way others were dressed, while those with high self-esteem indicated they would continue their counter-conformity in attire. When encountering dissonance induced by the perceived extreme similarity to others, both those with high and low self-esteem tended to say they would dress in an unorthodox manner to surprise other people in the future.

  8. Risetime discrimination applied to pressurized Xe gas proportional counter for hard x-ray detection

    International Nuclear Information System (INIS)

    Fujii, Masami; Doi, Kosei

    1978-01-01

    A high pressure Xe proportional counter has been developed for hard X-ray observation. This counter has better energy-resolving power than a NaI scintillation counter, and the realization of large area is relatively easy. This counter is constructed with a cylindrical aluminum tube, and this tube can be used at 40 atmospheric pressure. The detection efficiency curves were obtained in relation to gas pressure. It is necessary to reduce impurities in the Xe gas to increase the energy-resolving power of the counter. The increase of gas pressure made the resolving power worse. The characteristics of the counter were stable for at least a few months. The wave form discrimination was applied to reduce the background signals such as pulses caused by charged particles and gamma-ray. This method has been used for normal pressure counter, and in the present study, it was applied for the high pressure counter. It was found that the discrimination method was able to be applied to this case. (Kato, T.)

  9. Analysis of Thermal Stability of Different Counter on 28nm FPGA

    DEFF Research Database (Denmark)

    Gupta, Daizy; Yadav, Amit; Hussain, Dil muhammed Akbar

    2016-01-01

    In this paper we are presenting the power analysis for thermal awareness of different counters. The technique we are using to do the analysis is based on 28 nm FPGA tech-nique. In this work during implementation on FPGA, we are going to analyze thermal stability of different counters in temperatu...... range of 10oC, 30oC, 60oC, 90oC, 120oC. There is 90.36% reduction in leakage power of divide by 2 counter when we scale down the temperature from 120oC to 10oC and 49.61% reduction in leakage power of LFSR up counter when we scale down the temperature from 120oC to 10oC....

  10. Forensic Speaker Recognition Law Enforcement and Counter-Terrorism

    CERN Document Server

    Patil, Hemant

    2012-01-01

    Forensic Speaker Recognition: Law Enforcement and Counter-Terrorism is an anthology of the research findings of 35 speaker recognition experts from around the world. The volume provides a multidimensional view of the complex science involved in determining whether a suspect’s voice truly matches forensic speech samples, collected by law enforcement and counter-terrorism agencies, that are associated with the commission of a terrorist act or other crimes. While addressing such topics as the challenges of forensic case work, handling speech signal degradation, analyzing features of speaker recognition to optimize voice verification system performance, and designing voice applications that meet the practical needs of law enforcement and counter-terrorism agencies, this material all sounds a common theme: how the rigors of forensic utility are demanding new levels of excellence in all aspects of speaker recognition. The contributors are among the most eminent scientists in speech engineering and signal process...

  11. Ionic magnetic fluids in polar solvents with tuned counter-ions

    Energy Technology Data Exchange (ETDEWEB)

    Lopes Filomeno, C. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil); Kouyaté, M. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Cousin, F. [Lab. Léon Brillouin – CE-Saclay, Gif-sur-Yvette (France); Demouchy, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Dpt de physique, Univ. de Cergy Pontoise, Cergy-Pontoise (France); Dubois, E.; Michot, L.; Mériguet, G. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Perzynski, R., E-mail: regine.perzynski@upmc.fr [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Peyre, V.; Sirieix-Plénet, J. [Sorbonne Universités, UPMC Univ Paris 06, CNRS, Lab. PHENIX, Paris (France); Tourinho, F.A. [Grupo de Fluidos Complexos Inst. de Quimica, Univ. de Brasília, Brasília (DF) (Brazil)

    2017-06-01

    The aim of the present study is to propose a new reproducible method for preparing colloidal dispersions of electrostatically charged nanoparticles (NPs) in polar solvents with different kinds of counter-ions. Maghemite NPs are here dispersed in solvents of different dielectric constant, namely water, dimethylsulfoxide (DMSO) and an ionic liquid, ethylammonium nitrate (EAN). If the existence of a NP superficial charge happens to be necessary for the colloidal stability of the dispersions in these three solvents, the standard DLVO theory cannot be used any more to describe the colloidal stability in EAN. The structure of the dispersions and the strength of the interparticle repulsion are investigated by small angle X-ray scattering measurements, in association with Ludwig–Soret coefficient determinations. Specificities, associated to the nature of the counter-ions are identified in this work on the colloidal stability, on the interparticle repulsion and on the Ludwig–Soret coefficient. - Highlights: • A controlled synthesis of ionic magnetic fluids in three polar solvents is proposed. • Colloidal repulsion in the magnetic fluids depends on the counter-ion nature. • Soret coefficient of citrate-coated maghemite nanoparticles is probed in water-pH7. • Thermophilicity of nanoparticles depends on the nature of their counter-ions. • Nanoparticles dressed with same counter-ions have solvent-dependent thermoproperties.

  12. Construction techniques and operation principles of Geiger-Mueller counters using external cathode (Mazetype)

    International Nuclear Information System (INIS)

    Sevegnani, F.X.

    1988-01-01

    The construction techniques for external cathode (Maze) and internal cathode Geiger-Muller counters are described, showing the operation principles and the used material nature. More than 200 counter types were evaluated analysing their characteristics. The influence of several types of guard-rings was studied, for optimizing counter operation conditions. Plateaus of the order of 700 V with slope of 0,3%/100 V for the net counting rate, and 1400 V with a slope of 0,8/100 V for total counts using total pressure of 10 cmHg, were obtained. A counter for β detection, using blown glass window in one of the edges of the cylinder was constructed. Counters of long life using materials such as, mica, adhesive glues, etc., were obtained. The results shown that the best counter operation occurs when it is empty in a vacuum of 10 -5 mmHg. (M.C.K.) [pt

  13. Classical microdosimetry in radiation protection dosimetry and monitoring

    International Nuclear Information System (INIS)

    Waker, A.J.; Schrewe, U.; Burmeister, J.; Dubeau, J.; Surette, R.A.

    2002-01-01

    Classical microdosimetry concerns the measurement and analysis of the spectrum of radiation energy deposition events in simulated microscopic tissue-equivalent sites. Over the past three decades, classical microdosimetry has been extensively applied for the direct measurement of dosimetric quantities, such as the ambient dose equivalent, and for the spectroscopic properties of tissue-equivalent proportional counters that have led to the methods of mixed-field analysis and particle identification. This paper reviews some of the special applications of classical microdosimetry such as the determination of kerma coefficients, differential dosimetry and aviation dosimetry. Also reviewed are some of the technological innovations related to the application of microdosimetry in operational health physics and in particular the development of multi-element proportional counters and detectors based on gas microstrip technology. (author)

  14. A high-efficiency neutron coincidence counter for small samples

    International Nuclear Information System (INIS)

    Miller, M.C.; Menlove, H.O.; Russo, P.A.

    1991-01-01

    The inventory sample coincidence counter (INVS) has been modified to enhance its performance. The new design is suitable for use with a glove box sample-well (in-line application) as well as for use in the standard at-line mode. The counter has been redesigned to count more efficiently and be less sensitive to variations in sample position. These factors lead to a higher degree of precision and accuracy in a given counting period and allow for the practical use of the INVS counter with gamma-ray isotopics to obtain a plutonium assay independent of operator declarations and time-consuming chemicals analysis. A calculation study was performed using the Los Alamos transport code MCNP to optimize the design parameters. 5 refs., 7 figs., 8 tabs

  15. Annular shape silver lined proportional counter for on-line pulsed neutron yield measurement

    International Nuclear Information System (INIS)

    Dighe, P.M.; Das, D.

    2015-01-01

    An annular shape silver lined proportional counter is developed to measure pulsed neutron radiation. The detector has 314 mm overall length and 235 mm overall diameter. The central cavity of 150 mm diameter and 200 mm length is used for placing the neutron source. Because of annular shape the detector covers >3π solid angle of the source. The detector has all welded construction. The detector is developed in two halves for easy mounting and demounting. Each half is an independent detector. Both the halves together give single neutron pulse calibration constant of 4.5×10 4 neutrons/shot count. The detector operates in proportional mode which gives enhanced working conditions in terms of dead time and operating range compared to Geiger Muller based neutron detectors

  16. 35 years of existence of a whole-body counter in the Czech Republic - experience and prospects

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Cespirova, I.

    1998-01-01

    A whole-body counter was built up in the Czech Republic in 1962, this at the then Institute of the Hygiene of Labour and Occupational Diseases. The shielding was made of steel plates taken from Tiger tanks which remained in the country as aftermath of World War II. The detecting and evaluating parts of the counter were upgraded gradually. The original 4 scintillator detectors (10.16 cm x 12.7 cm in size) were replaced with an HPGe semiconductor detector exhibiting a roughly fifty-fold better resolution, owing to which radionuclide activities can be determined in complex matrices. Currently, the whole-body counter is equipped with a high-purity Ge detector displaying a relative efficiency of 120%, special detectors for low-energy gamma radiation, so-called LEGe detectors which are employed during the determination of radionuclides in the individual organs. The facility is applied to the monitoring of internal contamination in persons handling unsealed sources, monitoring in cases of suspect accidents associated with internal contamination of humans, as well as to the determination of internal contamination in epidemiological studies. In the past, a group of persons contaminated with radioactive fluorescent dyes which contained 226 Ra and 90 Sr, and a group of patients with applied thorotrast were also examined. Currently, methods which are under development are aimed at the determination of 210 Pb in the skulls of people who have been exposed to elevated radon concentrations in dwellings for a long time, and the determination of 241 Am in human bodies and their individual organs

  17. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  18. On the Performance of Counter-Based Broadcast Scheme for Mobile ...

    African Journals Online (AJOL)

    Despite its simplicity, it can result in high redundant retransmission, contention and collision, a phenomenon collectively referred to as the broadcast storm problem. Counter-based broadcast scheme has been proposed to mitigate this inherent problem and it relies on counter threshold value for rebroadcast decision. Thus ...

  19. Electronic system for recording proportional counter rare pulses with the pulse shape analysis

    International Nuclear Information System (INIS)

    Barabanov, I.R.; Gavrin, V.N.; Zakharov, Yu.I.; Tikhonov, A.A.

    1984-01-01

    The anutomated system for recording proportional counter rare pulses is described. The proportional counters are aimed at identification of 37 Ar and H7 1 Gr decays in chemical radiation detectors of solar neutrino. Pulse shape recording by means of a storage oscilloscope and a TV display is performed in the system considered besides two-parametric selection of events (measurement of pulse amplitude in a slow channel and the amplitude of pulse differentiated with time constant of about 10 ns in a parallel fast channel). Pulse discrimination by a front rise rate provides background decrease in the 55 Fe range (5.9 keV) by 6 times; the visual analysis of pulse shapes recorded allows to decrease the background additionally by 25-30%. The background counting rate in the 55 Fe range being equal to 1 pulse per 1.5 days, is obtained when using the installation described above, as well as the passive Pb shield 5 cm thick, and the active shield based on the anticoincidence NaI(Tl) detector with the cathode 5.6 mm in-diameter made of Fe fabircated by zone melting. The installation described allows to reach the background level of 0.6 pulse/day (the total coefficient of background attenuation is 400). Further background decrease is supposed to be provided by installation allocation in the low-noise underground laboratory of the Baksan Neutrino Observatory

  20. Radiation effects on the proportional counter X-ray detectors on board the NEAR spacecraft

    International Nuclear Information System (INIS)

    Floyd, S.R.; Trombka, J.I.; Leidecker, H.W.; Clark, P.E.; Starr, R.; Goldsten, J.O.; Roth, D.R.

    1999-01-01

    The X-ray proportional counters on board the Near Earth Asteroid Rendezvous (NEAR) spacecraft have exhibited a resolution degradation and recovery phenomenon several times during the long cruise phase of the mission. The resolution is checked periodically by commanding an 55 Fe source into the window area. The degradation is seen as a low energy tailing of the 5.9 keV photopeak. Two events have occurred which provided good spectral data for better understanding the degradation phenomenon. In November 1997 a large solar particle event occurred that degraded the resolution and excited copper in the collimator. Eventually the detectors returned to normal. In January 1998 the spacecraft performed an Earth swingby gravity assist maneuver. The near Earth environment excited the magnesium and aluminum in the filter elements. The copper line was also produced. The NEAR spacecraft was launched in February 1996 and will rendezvous and orbit the asteroid 433 Eros in early 1999

  1. Losing the Plot: Narrative, Counter-Narrative and Violent Extremism

    Directory of Open Access Journals (Sweden)

    Andrew Glazzard

    2017-05-01

    Full Text Available Counter-terrorist practitioners and policy makers appear to be very interested in narrative. They often describe the worldview of violent Islamist groups and movements as the ‘jihadi narrative’, while their efforts to confront terrorist propaganda are usually labelled as ‘counter-narrative’ or ‘alternative narrative’. However, while the counter-narrative approach has gained widespread acceptance in governments, think-tanks and civil society organisations, it is built on very shaky theoretical and empirical foundations. Some valuable theoretical contributions to the study of violent extremist narrative have been made by psychologists in particular, but there is one discipline which is conspicuous by its absence from the field: literary studies. This paper makes a case for the value of studying violent extremist narratives as narratives in the literary sense. By employing the tools and techniques of literary criticism, violent extremist communication can be revealed as not only potentially persuasive, but also creative and aesthetically appealing: terrorists inspire their followers, they don’t merely persuade them. Understanding the creative sources of this inspiration is vital if counter-narrative is to succeed in presenting an alternative to the propaganda of violent extremist groups.

  2. Improvements to a neutral radiation detection and position sensitive process and devices

    International Nuclear Information System (INIS)

    Charpak, Georges; Nguyen, N.H.; Policarpo, Armando.

    1977-01-01

    This invention aims to provide a neutral radiation position sensitive process and device providing a spatial radiation satisfactory for most medical applications and an energy radiation that cannot be reached by gas detectors based on proportional counters or by scintillation counters. Only solid state detectors can compete with respect to energy resolution. The detector described enables large areas to be covered which cannot be reached at accessible costs by solid state detectors. With this aim in view, the invention suggests an incident neutral radiation and position sensitive process, particularly soft gamma and X radiations, whereby photoelectrons are made to form by incident radiation action on gas atoms contained in an enclosure. By means of an electric field, the electrons are diverted towards a space undergoing an electric field high enough in value to create photons by exciting gas atoms and returning them to the de-excited state. The photons are collected, through a transparent window, on a layer of a material for converting such photons into scintillations in the near or visible UV spectrum and the barycentre of the scintillations is positioned on the layer, for instance by photomultipliers or ionization detectors. According to another aspect of the invention, it suggests a detection and position sensitive device comprising (generally downstream of a collimator with a grid of inlet holes) a leak tight containment fitted with an inlet window transparent to incident radiations, filled with a gas producing electrons by interaction with the incident radiation, and fitted with electrodes for generating an electric field to divert the electrons to a space for creating secondary photons [fr

  3. Experimental Observations on a Low Strain Counter-Flow Diffusion Flame: Flow and Bouyancy Effects

    Science.gov (United States)

    Sutula, J. A.; Torero, J. L.; Ezekoye, O. A.

    1999-01-01

    Diffusion flames are of great interest in fire safety and many industrial processes. The counter-flow configuration provides a constant strain flow, and therefore is ideal to study the structure of diffusion flames. Most studies have concentrated on the high velocity, high strain limit, since buoyantly induced instabilities will disintegrate the planar flame as the velocity decreases. Only recently, experimental studies in microgravity conditions have begun to explore the low strain regimes. Numerical work has shown the coupling between gas phase reaction rates, soot reaction rates, and radiation. For these programs, size, geometry and experimental conditions have been chosen to keep the flame unaffected by the physical boundaries. When the physical boundaries can not be considered infinitely far from the reaction zone discrepancies arise. A computational study that includes boundary effects and accounts for the deviations occurring when the major potential flow assumptions are relaxed was presented by Borlik et al. This development properly incorporates all heat loss terms and shows the possibility of extinction in the low strain regime. A major constraint of studying the low strain regime is buoyancy. Buoyant instabilities have been shown to have a significant effect on the nature of reactants and heat transport, and can introduce instabilities on the flow that result in phenomena such as flickering or fingering. The counter-flow configuration has been shown to provide a flame with no symmetry disrupting instabilities for inlet velocities greater than 50 mm/s. As the velocity approaches this limit, the characteristic length of the experiment has to be reduced to a few millimetres so as to keep the Rayleigh number (Ra(sub L) = (Beta)(g(sub 0))(L(exp 3) del T)/(alpha(v))) below 2000. In this work, a rectangular counter-flow burner was used to study a two-dimensional counter-flow diffusion flame. Flow visualisation and Particle Image Velocimetry served to describe

  4. Alternative modes for optical trapping and manipulation using counter-propagating shaped beams

    International Nuclear Information System (INIS)

    Palima, D; Tauro, S; Glückstad, J; Lindballe, T B; Kristensen, M V; Stapelfeldt, H; Keiding, S R

    2011-01-01

    Counter-propagating beams have enabled the first stable three-dimensional optical trapping of microparticles and this procedure has been enhanced and developed over the years to achieve independent and interactive manipulation of multiple particles. In this work, we analyse counter-propagating shaped-beam traps that depart from the conventional geometry based on symmetric, coaxial counter-propagating beams. We show that projecting shaped beams with separation distances previously considered axially unstable can, in fact, enhance the axial and transverse trapping stiffnesses. We also show that deviating from using perfectly counter-propagating beams to use oblique beams can improve the axial stability of the traps and improve the axial trapping stiffness. These alternative geometries can be particularly useful for handling larger particles. These results hint at a rich potential for light shaping for optical trapping and manipulation using patterned counter-propagating beams, which still remains to be fully tapped

  5. Which future for nuclear counter-proliferation?

    International Nuclear Information System (INIS)

    Duval, M.

    2010-01-01

    Dealing with the case of nuclear weapons possessed by nuclear states (but not eventually by terrorists), the author first identifies the constants of counter-proliferation: it is linked to interest conflicts between those who try to preserve their monopoly and those who try to acquire a new weapon either because of a threat or for reasons of regional prestige, the evolution from use to deterrence, the appearance of new actors after the USA and Russia, the role of nuclear tactical weapons, and the future of Russian weapons and know-how. He presents the international counter-proliferation context: the Non Proliferation Treaty (NPT), the IAEA and its controls, the Nuclear Supplier Group (NSG), the nuclear-free zones, the Comprehensive Test Ban Treaty (CTBT), the Missile Technology Control Regime (MTCR). He describes how and why proliferation occurs: uranium enrichment and plutonium technology, political reasons in different parts of the world. Then, he gives an overview of the proliferation status by commenting the cases of Israel, Iraq, India, Pakistan, North Korea, and Iran. He discusses the future of proliferation (involved countries, existence of a nuclear black market) and of counter-proliferation as far as Middle-East and North Korea are concerned. He tries finally to anticipate the consequences for nuclear deterrence strategy, and more particularly for Europe and France

  6. 300-MHz optical discriminator-counter

    International Nuclear Information System (INIS)

    Turko, B.; Lo, C.C.

    1981-07-01

    The prediction of future CO 2 content in the atmosphere is not completely credible because the oceanographers and terrestrial ecologists do not agree on the global CO 2 balance. Very precise measurements of O 2 /N 2 ratio using Raman scattering over a few years' period could provide important information and lead to the explanation of the disparity in the atmospheric CO 2 balance. An optical discriminator-counter has been developed to count closely spaced optical events in the few photon level. Simulated optical events as close as 2.5 ns apart had been positively detected by using selected photomultipliers and optimized discriminators. Testing of the optical discriminator-counter was done by using an electrical pulse pair spaced 3 ns apart and also by a similar optical pulse pair generated by fast light-emitting diode. The photomultiplier is capable of counting an average single photoelectron pulse frequency of 50 MHz and has a sensitive detecting area of 50 mm in diameter. The discriminator performance is discussed

  7. Using Counter-Stories to Challenge Stock Stories about Traveller Families

    Science.gov (United States)

    D'Arcy, Kate

    2017-01-01

    Critical Race Theory (CRT) is formed from a series of different methodological tools to expose and address racism and discrimination. Counter-stories are one of these tools. This article considers the potential of counter-stories as a methodological, theoretical and practical tool to analyse existing educational inequalities for Traveller…

  8. Improved Technology To Prevent Nuclear Proliferation And Counter Nuclear Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, J; Yuldashev, B; Labov, S; Knapp, R

    2006-06-12

    As the world moves into the 21st century, the possibility of greater reliance on nuclear energy will impose additional technical requirements to prevent proliferation. In addition to proliferation resistant reactors, a careful examination of the various possible fuel cycles from cradle to grave will provide additional technical and nonproliferation challenges in the areas of conversion, enrichment, transportation, recycling and waste disposal. Radiation detection technology and information management have a prominent role in any future global regime for nonproliferation. As nuclear energy and hence nuclear materials become an increasingly global phenomenon, using local technologies and capabilities facilitate incorporation of enhanced monitoring and detection on the regional level. Radiation detection technologies are an important tool in the prevention of proliferation and countering radiological/nuclear terrorism. A variety of new developments have enabled enhanced performance in terms of energy resolution, spatial resolution, passive detection, predictive modeling and simulation, active interrogation, and ease of operation and deployment in the field. For example, various gamma ray imaging approaches are being explored to combine spatial resolution with background suppression in order to enhance sensitivity many-fold at reasonable standoff distances and acquisition times. New materials and approaches are being developed in order to provide adequate energy resolution in field use without the necessity for liquid nitrogen. Different detection algorithms enable fissile materials to be distinguished from other radioisotopes.

  9. Counter-Leadership Targeting and Conflict Termination

    National Research Council Canada - National Science Library

    Taylor, Bradly

    1999-01-01

    .... Can the leader be found? And, is it legal and ethical to attack the leader? Analysis rarely has been conducted to determine whether the targeted organization is vulnerable to Counter Leadership Targeting (CLT...

  10. An acoustical bubble counter for superheated drop detectors

    International Nuclear Information System (INIS)

    Taylor, C.; Montvila, D.; Flynn, D.; Brennan, C.; D'Errico, F.

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons. (authors)

  11. An acoustical bubble counter for superheated drop detectors.

    Science.gov (United States)

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  12. Radiation protection metrology at a high-energy neutron therapy facility

    International Nuclear Information System (INIS)

    Bonnett, D.E.; Sherwin, A.G.; More, B.R.

    1991-01-01

    A radiation protection survey has been carried out at a high-energy neutron therapy facility using a combination of different detectors and counters. Included in the survey were measurements with a tissue equivalent proportional counter (TEPC), a rem meter, a large volume ionisation chamber (LVI) and a Geiger counter. Dose equivalent rates, normalised to a proton beam current of 25 μA, of between 1 μSv.h -1 and 0.7 Sv.h -1 were recorded depending on the location. In general the results confirm the tendency of the rem meter to over-read in fields consisting mainly of low energy neutrons and illustrate the advantages of the diagnostic and gamma discriminating properties of the TEPC. The LVI-Geiger system was found to be the least favourable combination of dosemeters, substantially under-reading and being unable to estimate the neutron dose rate at levels below about 32 μGy.h -1 . (author)

  13. Counter radicalization development assistance

    OpenAIRE

    van Hippel, Karin

    2006-01-01

    The paper reviews current research and practice and recommends strategies for development agencies working in the Arab and Muslim world. It builds on the basic assumption that the realization of the Millennium Development Goals will be vital to reduce support for terrorism in the long term. Within this overall framework, emphasis is placed on particular programs that could be specifically applied to counter radicalization.

  14. Neutron measuring instruments for radiation protection

    International Nuclear Information System (INIS)

    Heinzelmann, M.; Schneider, W.; Hoefert, M.; Kuehn, H.; Jahr, R.; Wagner, S.; Piesch, E.

    1979-09-01

    The present report deals with selected topics from the field of neutron dosimetry for radiation protection connected with the work of the subcommittee 6802 in the Standards Committee on Radiology (NAR) of the German Standards Institute (DIN). It is a sort of material collection. The topics are: 1. Measurement of the absorbed-energy dose by a) ionization chambers in fields of mixed radiation and b) recoil-proton proportional counting tubes. 2. Measurement of the equivalent dose, neutron monitors, combination methods by a) rem-meters, b) recoil-proton counting tubes, c) recombination method, tissue-equivalent proportional counters, activation methods for high energies in fields of mixed radiation, d) personnel dosimetry by means of ionization chambers and counting tubes, e) dosimetry by means of activation methods, nuclear track films, nonphotographic nuclear track detectors and solid-state dosimeters. (orig./HP) [de

  15. Hardware enabled performance counters with support for operating system context switching

    Science.gov (United States)

    Salapura, Valentina; Wisniewski, Robert W.

    2015-06-30

    A device for supporting hardware enabled performance counters with support for context switching include a plurality of performance counters operable to collect information associated with one or more computer system related activities, a first register operable to store a memory address, a second register operable to store a mode indication, and a state machine operable to read the second register and cause the plurality of performance counters to copy the information to memory area indicated by the memory address based on the mode indication.

  16. Counter-Stereotypes and Images: An Exploratory Research and Some Questions

    Science.gov (United States)

    Morin-Messabel, Christine; Ferrière, Séverine; Martinez, Frederic; Devif, Julie; Reeb, Laurence

    2017-01-01

    The dynamics of the construction and perpetuation of gender stereotypes are classic research subjects in social psychology and in the field of educational guidelines in France. The most recent government decree aims to counter stereotypes in schools, by exposing pupils to counter-stereotypes. This study examines the effects of activating…

  17. Development of failure-detecting device for γ radioimmunoassay counter

    International Nuclear Information System (INIS)

    Shao Xianzhi; Zhang Bingfeng

    1997-01-01

    A failures-detecting device based on single chip microcomputer technique for detecting of failures of γ radioimmunoassay counter is developed. The device can output signals of variable amplitude and frequency similar to the pulse of γ particle for shooting problem parts of γ counter's detecting system. By automatically comparing the shapes and amplitudes of the two signals to and from an amplifier unit, the device can distinguish if the amplifier unit works normally. The differential-input amplifier circuit gives 0.1% accuracy for the measurement of the stability of high voltage. The pulse widen circuit of this device allows for middle speed A/D detecting of periodical low-frequency pulse waves of micro-second width. This device is used specifically for the maintaining and failure-detecting of γ radioimmunoassay counter

  18. Wind tunnel tests of stratospheric airship counter rotating propellers

    Directory of Open Access Journals (Sweden)

    Yaxi Chen

    2015-01-01

    Full Text Available Aerodynamic performance of the high-altitude propeller, especially the counter rotation effects, is experimentally studied. Influences of different configurations on a stratospheric airship, included 2-blade counter-rotating propeller (CRP, dual 2-blade single rotation propellers (SRPs and 4-blade SRP, are also indicated. This research indicates that the effect of counter rotation can greatly improve the efficiency. It shows that the CRP configuration results in a higher efficiency than the dual 2-blade SRPs configuration or 4-blade SRP configuration under the same advance ratio, and the CRP configuration also gains the highest efficiency whether under the situation of providing the same trust or absorbing the same power. It concludes that, for a stratospheric airship, the CRP configuration is better than the multiple SRPs configuration or a multi-blade SRP one.

  19. Interactive hypermedia training manual for spent-fuel bundle counters

    International Nuclear Information System (INIS)

    Basso, R.A.

    1990-07-01

    Spent-fuel bundle counters, developed by the Canadian Safeguards Support Program for the International Atomic Energy Agency, provide a secure and independent means of counting the number of irradiated fuel bundles discharged into the fuel storage bays at CANDU nuclear power stations. Paper manuals have been traditionally used to familiarize IAEA inspectors with the operation, maintenance and extensive reporting capabilities of the bundle counters. To further assist inspectors, an interactive training manual has been developed on an Apple Macintosh computer using hypermedia software. The manual uses interactive animation and sound, in conjunction with the traditional text and graphics, to simulate the underlying operation and logic of the bundle counters. This paper presents the key features of the interactive manual and highlights the advantages of this new technology for training

  20. International whole body counter intercomparison based on BOMAB phantom simulating 4 years old child

    International Nuclear Information System (INIS)

    Battisti, P.; Tarroni, G.

    1995-11-01

    In April 1993 a whole body counter intercomparison campaign, The 1993 Intercomparison/Intercalibration, started. The campaign has been organized by The Canadian National Reference Centre for In-Vivo Monitoring of Radiation Protection Bureau, Health Canada and The United States Department of Energy and it was based on measurements on a BOMAB type phantom simulating a 4 years old child. The phantom was filled with radioactive tissue substitute resin and an unknown quantity of radioactivity. Each facility was asked to determine the identity and amount of the radionuclide(s), knowing that the specific activity in the 10 BOMAB's sections was the same. Each facility was also asked to calculate the minimum detectable activity of all the radionuclides detected in the phantom. 35 Facilities from 20 different Countries took part in the initiative. The Institute for Radiation Protection of the Environment Department of ENEA (ENEA AMB IRP) represented Italy. Intercomparison results supplied by ENEA AMB IRP as radionuclides identification, activity data and associated precision, minimum detectable activity levels, can be considered satisfactory and comparable with results supplied by similar-facilities

  1. Determination of cosmic ray produced radionuclides by means of background radiation counting system, 3

    International Nuclear Information System (INIS)

    1976-01-01

    This is the third report of the progress report series on studies of cosmic ray produced radionuclides by means of low background radiation counting system. In Part I some characteristics of a low beta-gamma coincidence spectrometer are described -- counter system, electronics, background spectra, counting efficiencies -- and studies on radioactive impurities in materials for scientific research are also described. In Part II, suitable solvents for a large scale liquid scintillation counter were examined and best combinations of solvents, solutes and naphthalene are shown. In Part III, miscellaneous topics are reported. (auth.)

  2. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    Science.gov (United States)

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  3. Application of a background-compensated Geiger-Mueller counter to a survey meter

    International Nuclear Information System (INIS)

    Mori, C.; Kumanomido, H.; Watanabe, T.

    1984-01-01

    A background-compensated Geiger-Mueller counter was used as a probe for a GM survey meter to obtain a net count rate of β-rays from a radioactive source in a quick survey. Although a background counting ratio between the two parts in the counter, front and rear, varied somewhat depending on the incident direction of background γ-rays, it was possible to compensate the background counts by subtracting a part of the rear counts, which were background counts, from the front counts, which contained β-ray counts and background counts. Undesirable small pulses generated during the recovering time after a full Geiger discharge were eliminated by an anticoincidence gating method. The survey meter with this counter and a differential ratemeter is useful for obtaining a net count rate of β-rays emitted from a surface radioactive-contamination or from a source being put near the window of the counter with nearly the same accuracy in half the measuring time as compared with conventional GM counters. (orig.)

  4. Test of long scintillating counter prototypes for CDF-II

    International Nuclear Information System (INIS)

    Budagov, Yu.; Chirikov-Zorin, I.; Pukhov, O.; Incagli, M.; Leone, S.; Menzione, A.; Pauletta, G.; Tokar, S.

    2000-01-01

    New type long (up to 3 m) scintillating counter prototypes, developed for CDF-II, have been tested. The shift-spectrum fiber ribbons were used for light collection, and modern ultra compact photomultipliers R5600 were used for light detection. The efficiency for m.i.p. was excellent for all prototypes. The light yield from the far end of the counters was found to be more than 20 photoelectrons

  5. Physical properties of the TOF (time of flight) scintillation counters of DELPHI

    International Nuclear Information System (INIS)

    Benlloch, J.M.; Castillo, M.V.; Ferrer, A.; Fuster, J.; Higon, E.; Llopis, A.; Salt, J.; Sanchez, E.; Sanchis, E.; Silvestre, E.; Cuevas, J.

    1990-01-01

    In this paper we report the physical properties of the time of flight (TOF) scintillator counters used for the DELPHI Experiment at CERN. We discuss the different choices studied for the wrapping of the counters in order to obtain best efficiencies for light transmission. A very good agreement of the performances of the counters has been found with the results of an original Monte Carlo program. The main characteristics of the TOF counters of DELPHI are: an effective light attenuation length of 135 cm, effective light speed of 15.91 cm/ns, a time resolution of 1.2 ns, and an efficiency for detection of minimum ionizing particles of 99.9%. (orig.)

  6. Using Delphi to realize the function of the γ-immuno counter

    International Nuclear Information System (INIS)

    Qi Na; Chu Yan; He Wenhua

    2005-01-01

    This paper introduces the concept of Radioimmunoassay and the background of the γ-immuno counter, summarizes the feature of the Delphi and discusses the superiority of using language of Delphi to realize the function of γ-immuno counter. (authors)

  7. Multicultural Young Adult Literature as a Form of Counter-Storytelling

    Science.gov (United States)

    Hughes-Hassell, Sandra

    2013-01-01

    Counter-storytelling is defined by critical race theory scholars as a method of telling the stories of those people whose experiences are not often told, including people of color, the poor, and members of the LGBTQ community. This article discusses multicultural young adult literature as a form of counter-storytelling, with an emphasis on how…

  8. A large multi-cell threshold gas Cerenkov counter

    International Nuclear Information System (INIS)

    Declais, Y.; Aubert, J.J.; Bassompierre, G.; Payre, P.; Thenard, J.M.; Urban, L.

    1980-08-01

    A large multi-cell threshold gas Cerenkov counter consisting of 78 cells has been built for use in a high energy muon scattering experiment at CERN (European Muon Collaboration). It is used with neon, nitrogen or a mixture of those two gases, allowing the pion threshold to be varied between 6 and 20 GeV/c. The sensitive region of the counter has a length of 4.0 m and entrance and exit windows of 1.1 x 2.4 m 2 and 2.4 x 5.0 m 2 , respectively

  9. Real-time aerosol photometer and optical particle counter comparison

    International Nuclear Information System (INIS)

    Santi, E.; Belosi, F.; Santachiara, G.; Prodi, F.; Berico, M.

    2010-01-01

    The paper presents the results of a comparison exercise among real-time aerosol samplers, based on different light scattering techniques. The comparison was carried out near to the ISAC institute in a box positioned inside the CNR research area in Bologna. Two nephelometers (Dust Trak from TSI, and Air Genius from Unitec) and an optical particle counter (ENVIRO-check from Grimm) were used for P M1 and P M10 fraction assessment. In the case of the optical particle counter, the particle number concentration in each size bin was also used. In parallel, two manual sampling lines were employed for reference (gravimetric) measurements. The results highlight different factor scales for the dust monitors, in comparison with gravimetric assessment, underlining the importance of a user calibration of such monitors as a function of the specific aerosol sampled. Moreover, the relative fluctuations of the hourly P M 10 and P M1 concentrations, against daily average concentrations, were studied in order to compare the ability of each sampler to follow changes in the aerosol size distribution. It was found that the photometers and optical particle counter revealed different behaviours. In the latter, a small increase in the particle concentration number in the coarse fraction gave a relatively high increase in the mass concentration that was not measured by the photometers. The explanation could be the relatively slight influence of a small particle number variation on the total scattered light for the photometers, unlike the case of the optical particle counter, where each particle contributes to the mass concentration. This aspect merits future research in order to better understand optical particle counter output used in P Mx monitoring activities.

  10. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    OpenAIRE

    Zhang, Guofeng; Zhu, Hanjie

    2015-01-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the ...

  11. Characteristics of proportional counters used in X-ray radiometric analysis

    International Nuclear Information System (INIS)

    Mamikonyan, S.V.; Martishchenko, L.G.; Mel'ttser, L.V.

    1972-01-01

    Counters with extended (up to 10 cm 2 ) apertres have been described and the results obtained are presented. CPM-15 and CPM-16 counters are intended for sensoring and spectral analysis of X-rays in the range of 2.5 to 23 and 2.5 to 15 keV, respectively. The only difference is in the gas composition. The CPM-15 counter is filled with 90 per cent xenon plus 10 per cent methane used as a quenching dopant. The CPM-16 is filled with 90 per cent argon and 10 per cent methane. The life time is 10 10 pulses at 1800 V for CPM-16 and at 2200 V for CPM-15

  12. A Survey of Teenagers' Attitudes Toward Moving Oral Contraceptives Over the Counter.

    Science.gov (United States)

    Manski, Ruth; Kottke, Melissa

    2015-09-01

    Evidence suggests that over-the-counter access to oral contraceptives may help expand use among adult women. Teenagers may particularly benefit from this approach, as they experience disproportionately high rates of unintended pregnancy and face unique challenges accessing contraceptives. However, limited research has explored teenagers' attitudes toward over-the-counter access. In 2014, a sample of 348 females aged 14-17, recruited via Facebook advertisements, participated in an online survey assessing teenagers' attitudes toward over-the-counter access and their understanding of how to use oral contraceptives after reading a prototype over-the-counter product label. Differences by participants' characteristics were assessed in bivariate analyses (Pearson chi-square and Fisher's exact tests for categorical measures, and independent t tests and one-way analyses of variance for continuous measures). Seventy-three percent of participants supported over-the-counter access, and 61% reported that they would likely use oral contraceptives available through this approach. Few subgroup differences were found. Notably, sexually experienced participants were significantly more likely than others both to support this approach (85% vs. 63%) and to be interested in obtaining oral contraceptives this way (77% vs. 48%). Participants understood an average of 7.1 of eight key concepts that the prototype product label was intended to convey; no significant differences were found among subgroups. Over-the-counter access may be a promising approach for providing oral contraceptives to teenagers. Additional research is needed to evaluate whether teenagers can screen themselves for contraindications to oral contraceptive use and correctly use oral contraceptives obtained over the counter. Copyright © 2015 by the Guttmacher Institute.

  13. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  14. Emergent information technologies and enabling policies for counter-terrorism

    CERN Document Server

    Popp, R

    2006-01-01

    Explores both counter-terrorism and enabling policy dimensions of emerging information technologies in national security After the September 11th attacks, "connecting the dots" has become the watchword for using information and intelligence to protect the United States from future terrorist attacks. Advanced and emerging information technologies offer key assets in confronting a secretive, asymmetric, and networked enemy. Yet, in a free and open society, policies must ensure that these powerful technologies are used responsibly, and that privacy and civil liberties remain protected. Emergent Information Technologies and Enabling Policies for Counter-Terrorism provides a unique, integrated treatment of cutting-edge counter-terrorism technologies and their corresponding policy options. Featuring contributions from nationally recognized authorities and experts, this book brings together a diverse knowledge base for those charged with protecting our nation from terrorist attacks while preserving our civil liberti...

  15. Gold leaf counter electrodes for dye-sensitized solar cells

    Science.gov (United States)

    Shimada, Kazuhiro; Toyoda, Takeshi

    2018-03-01

    In this study, a gold leaf 100 nm thin film is used as the counter electrode in dye-sensitized solar cells. The traditional method of hammering gold foil to obtain a thin gold leaf, which requires only small amounts of gold, was employed. The gold leaf was then attached to the substrate using an adhesive to produce the gold electrode. The proposed approach for fabricating counter electrodes is demonstrated to be facile and cost-effective, as opposed to existing techniques. Compared with electrodes prepared with gold foil and sputtered gold, the gold leaf counter electrode demonstrates higher catalytic activity with a cobalt-complex electrolyte and higher cell efficiency. The origin of the improved performance was investigated by surface morphology examination (scanning electron microscopy), various electrochemical analyses (cyclic voltammetry, linear sweep voltammetry, and electrochemical impedance spectroscopy), and crystalline analysis (X-ray diffractometry).

  16. Simulation of scanning geometry for Shadow Shield counter using Monte Carlo method

    International Nuclear Information System (INIS)

    Deepu, R.; Manohari, M.; Mathiyarasu, R.

    2018-01-01

    The whole body counting facility at RSD, IGCAR employs a Shadow Shield Counter (SSC) for the assessment of internal exposure of radiation workers from fission and activation products. The SSC system is routinely calibrated using an in-house built Masonite cut sheet phantom, loaded with standard point sources, in scanning mode. The system is capable of measuring gamma energy from 200 keV to 3 MeV. The standard sources available have energies in the range of 300 - 1500 keV. In order to extend the energy range, numerical simulation can be carried out. As, numerical methods cannot simulate scanning mode directly, a novel scheme is attempted to generate the efficiency value for scanning mode through the use of multiple static mode. The same method was also verified through measurement. The efficiency values of the simulation as well two measurements techniques were compared

  17. Tobacco counter-advertising: a review of the literature and a conceptual model for understanding effects.

    Science.gov (United States)

    Agostinelli, Gina; Grube, Joel W

    2003-01-01

    The tobacco counter-advertising literature is reviewed as it relates to basic process questions concerning what makes counter-advertisements effective. Limitations in addressing (a) counter-advertisement content and the psychological mediators targeted, (b) counter-advertisement style and the affective reactions targeted, (c) prior smoking experience, and (d) other audience factors are enumerated. A theoretical model based on alcohol advertising research is presented to address those limitations. The model addresses the practical research question of predicting when tobacco counter-advertising will work by examining the independent influence of each of these enumerated factors, as well as how these factors operate in concert, qualifying each other. The model also addresses the process question of explaining how counter-advertising works by identifying affective and cognitive processes as mediators. By understanding the processes that underlie the qualified findings, one can better advise the designers of tobacco counter-advertisements how to be more effective.

  18. Occupational radiation exposure in the GDR in 1977

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1977, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,348 persons), measurements with a whole-body counter (198 persons) and analyses of biosamples (174 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 253. In 6 cases the monthly exposure exceeded 30 mGy and the 9 highest annual exposure values were in the range of 50 to 120 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual radiation exposure was below one-tenth the maximum permissible dose. (author)

  19. PERUMUSAN STRATEGI PEMASARAN FRY COUNTER DENGAN PENDEKATAN MODEL AIDA

    OpenAIRE

    Andi Oktoriyana; Ujang Sumarwan; Hartoyo Hartoyo

    2014-01-01

    This research examined factors which are mentioned in various literatures that have influence on AIDA models to buy fry counter which are attention, interest, and desire. The model also influenced by perceived attributes, personal characteristics, and external factors. Furthermore, the analysis result become a basic for formulating the marketing strategy of fry counter as an innovative product. Analysis was carried out using Structural Equation Modeling. The data for this study were collected...

  20. Using DMA for copying performance counter data to memory

    Science.gov (United States)

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W

    2013-12-31

    A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance data.

  1. Unravelling radiation response: from public health to personalized radiotherapy

    International Nuclear Information System (INIS)

    Manna, Soumen Kanti

    2017-01-01

    Understanding the mechanism underlying response to ionizing radiation exposure is at the heart of radiation biology and its applications. This presentation will showcase how the mass spectrometry-based global profiling helped to identify not only potential age-independent biomarkers of ionizing radiation exposure in mice but also a hitherto unexplored link between DNA repair and polyamine metabolism at an organismal level. It will then provide a glimpse of how a combination of metabolomics and molecular biological tools combined to elucidate the metabolic reprogramming underlying therapeutic resistance of cancer cells. It will then elaborate how an integrated -omics approach could be adopted to understand the heterogeneity in the effects ionizing radiation in the context of development and health. Finally, it will present a framework on how clinicians, epidemiologists and basic researchers can come together to usher in a new era of personalized radiation therapy as well as to develop a paradigm of personalized counter measures against radiation exposure. (author)

  2. Calibration and validation of measures a total alpha beta counter in the tunisian mineral water

    International Nuclear Information System (INIS)

    Nasri, Sihem; Skhiri, Noura

    2009-01-01

    The risks due to contamination of mineral waters are essentially risk internal radiation following ingestion of radionuclides which brought us in this study to determine the global alpha and beta of the Tunisian mineral water. We used an alpha beta global counter. The results obtained by this technique have shown that alpha activity of these 10 waters are all lower than 50 mBq / l and are varied between 3.75 and 8.4 mBq / l and beta activity was found only 9 waters are also lower than 50 mBq / l (between 7.17 and 18.25) when only one is between 100 and 500 mBq / l (101.17).

  3. Dead zone characteristics of a gas counter

    International Nuclear Information System (INIS)

    Nohtomi, Akihiro; Sakae, Takeji; Matoba, Masaru; Koori, Norihiko.

    1990-01-01

    The dead zone was recently defined as the product of dead length and dead time in order to describe the characteristics of the self-quenching streamer (SQS) mode of a gas counter. Investigation of the dead zone characteristics has been extended for the proportional and GM modes, and the measured dead zone has been compared with that of the SQS mode. Accurate values for the dead zone could be determined by means of a newly developed method with a pulse interval time to amplitude converter. Each operation mode indicates distinct dead zone characteristics. Properties of gas counters for high counting rates may be improved on the basis of measurements of the dead zone. (author)

  4. A Fear Management Approach to Counter-Terrorism

    Directory of Open Access Journals (Sweden)

    Tinka Veldhuis

    2012-02-01

    Full Text Available Spreading fear is the essence of terrorism. Terrorists exploit fear by terrorising the target audience into concessions. Understanding how feelings of fear influence the way people feel, think and act is therefore an important starting point to explore how individuals and societies can learn how to cope with fear of terrorism. In this Policy Brief, Research Fellows Prof. Dr. Edwin Bakker and Dr. Tinka Veldhuis explore the dynamics of fear in response to terrorism, and emphasise the importance of integrating initiatives to manage fear of terrorism and reduce its negative consequences into overarching counter-terrorism strategies. It argues that societies can benefit greatly from promoting resilience and a fear management approach to counter-terrorism.

  5. Flooding in counter-current two-phase flow

    International Nuclear Information System (INIS)

    Ragland, W.A.; Ganic, E.N.

    1982-01-01

    Flooding is a phenomenon which is best described as the transition from counter-current to co-current flow. Early notice was taken of this phenomenon in the chemical engineering industry. Flooding also plays an important role in the field of two-phase heat transfer since it is a limit for many systems involving counter-current flow. Practical applications of flooding limited processes include wickless thermosyphons and the emergency core cooling system (ECCS) of pressurized water nuclear reactors. The phenomenon of flooding also is involved in the behavior of nuclear reactor core materials during severe accident conditions where flooding is one of the mechanisms governing the motion of the molten fuel pin cladding

  6. Flooding in counter-current two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Ragland, W.A.; Ganic, E.N.

    1982-01-01

    Flooding is a phenomenon which is best described as the transition from counter-current to co-current flow. Early notice was taken of this phenomenon in the chemical engineering industry. Flooding also plays an important role in the field of two-phase heat transfer since it is a limit for many systems involving counter-current flow. Practical applications of flooding limited processes include wickless thermosyphons and the emergency core cooling system (ECCS) of pressurized water nuclear reactors. The phenomenon of flooding also is involved in the behavior of nuclear reactor core materials during severe accident conditions where flooding is one of the mechanisms governing the motion of the molten fuel pin cladding.

  7. Visualization study of helium-air counter flow through a small opening

    International Nuclear Information System (INIS)

    Fumizawa, Motoo

    2007-01-01

    Buoyancy-driven counter flows of helium-air were investigated through horizontal and inclined small openings. Counter flows may occur following a window opening as ventilation, fire in the room as well as a pipe rupture accident in a high temperature gas-cooled nuclear reactor. The experiment has carried out by a test chamber filled with helium and flow was visualized by the smoke wire method. The flow behavior has recorded by a high-speed camera with a computer system. The image of the flow was transferred to the digital data, thus the flow velocity was measured by PTV software. The mass fraction in the test chamber was measured by electronic balance. The detected data was arranged by the densimetric Floude number of the counter flow rate that derived from the dimensional analysis. The method of mass increment was developed and applied to measure the counter flow rate. By removing the cover plate placed on the top of the opening, the counter flow initiated. Air enters the test chamber and the mass of the gas mixture in the test chamber increased. The volumetric counter flow rate was evaluated from the mass increment data. In the case of inclination openings, the results of both methods were compared. The inclination angle for maximum densimetric Floude number decreased with increasing length-to-diameter ratio of the opening. For a horizontal opening, the results from the method of mass increment agreed with those obtained by other authors for a water-brine system. (author)

  8. Radiation methods for purification of water, wastewater and flue gases at international chemical congress of Pacific basic societies

    International Nuclear Information System (INIS)

    Pikaev, A.K.

    1996-01-01

    Content of report, presented at the symposium Ecological applications of ionizing radiation (water, waste water and technological waste products), which took place within the frames of the International Chemical Congress of the Pacific Ocean Region counters (the PacifiChem'95, December 17-22, 1995, Honolulu, Hawaii, USA) is briefly presented. The problems on electron-radiation purification of natural water, domestic and technological waste waters, flue gases and contaminated soils, radiation treatment of the waste water sediments, ionizing radiation sources, applied in this area of technology and economics of radiation purification methods were discussed

  9. Countering North Korean Special Purpose Forces

    National Research Council Canada - National Science Library

    Krause, Troy

    1999-01-01

    As United States and Republic of Korea forces stand to defend against a DPRK attack, one of the most formidable tasks is how to counter a second front in the Joint Rear Security Area of the Republic of Korea...

  10. VOICES AGAINST EXTREMISM: A CASE STUDY OF A COMMUNITY-BASED CVE COUNTER-NARRATIVE CAMPAIGN

    Directory of Open Access Journals (Sweden)

    Logan Macnair

    2017-03-01

    Full Text Available This article presents a case study of the recently conceived and ongoing counter-extremism campaign, Voices Against Extremism, a campaign designed and implemented by university students from Vancouver, Canada. Through a multifaceted approach that includes extensive use of social media, academic research, and grassroots community activities and involvement, Voices Against Extremism operates under the mission statement of countering and preventing violent extremism and radicalization through the humanization of minority groups and through the education and engagement of the silent majority. This article examines the effectiveness of this campaign as a proactive counter-radicalization strategy by outlining its specific components and activities. Based on the results of this campaign, suggestions are then offered regarding specific counter-extremism and counter-radicalizations policies that may be adopted by law enforcement, policymakers – or any other organizations concerned with countering and preventing radicalization and violent extremism – with a specific focus on the potential benefits of proactive and long-term social and community engagement.

  11. Amelioration of radiation-induced pulmonary fibrosis by a water-soluble bifunctional sulfoxide radiation mitigator (MMS350).

    Science.gov (United States)

    Kalash, Ronny; Epperly, Michael W; Goff, Julie; Dixon, Tracy; Sprachman, Melissa M; Zhang, Xichen; Shields, Donna; Cao, Shaonan; Franicola, Darcy; Wipf, Peter; Berhane, Hebist; Wang, Hong; Au, Jeremiah; Greenberger, Joel S

    2013-11-01

    A water-soluble ionizing radiation mitigator would have considerable advantages for the management of acute and chronic effects of ionizing radiation. We report that a novel oxetanyl sulfoxide (MMS350) is effective both as a protector and a mitigator of clonal mouse bone marrow stromal cell lines in vitro, and is an effective in vivo mitigator when administered 24 h after 9.5 Gy (LD100/30) total-body irradiation of C57BL/6NHsd mice, significantly improving survival (P = 0.0097). Furthermore, MMS350 (400 μM) added weekly to drinking water after 20 Gy thoracic irradiation significantly decreased: expression of pulmonary inflammatory and profibrotic gene transcripts and proteins; migration into the lungs of bone marrow origin luciferase+/GFP+ (luc+/GFP+) fibroblast progenitors (in both luc+ marrow chimeric and luc+ stromal cell line injected mouse models) and decreased radiation-induced pulmonary fibrosis (P < 0.0001). This nontoxic and orally administered small molecule may be an effective therapeutic in clinical radiotherapy and as a counter measure against the acute and chronic effects of ionizing radiation.

  12. CCM-R: Secure Counter Synchronization for IoT Wireless Link

    DEFF Research Database (Denmark)

    Roy, Upal; Yin, Jiachen; Andersen, Birger

    2016-01-01

    In this paper we propose and evaluate a new version of the CCM mode of operation, CCM-R, which isan extended and alternate version of the original CBC-MAC with Counter Mode(CCM) that was created to address the problem of counter synchronization. While CCM is considered secure when used/implemente...... it suitable for low-power wireless IoT devices....

  13. Position-sensitive proportional counters using resistance-capacitance position encoding

    International Nuclear Information System (INIS)

    Kopp, M.K.; Borkowski, C.J.

    1975-12-01

    A new method was developed for encoding the position of individual photons, neutrons, or charged particles in proportional counters by using the distributed RC line characteristics of these counters. The signal processing is described and guidelines for the design and operation of these position sensitive proportional counters (PSPCs) are given. Using these guidelines, several prototypic PSPCs were constructed to improve the spatial resolution and shorten the signal processing time; for example, the intrinsic spatial uncertainty was reduced to 28 μ fwhm for alpha particles and 100 μ fwhm for low-energy x rays (2 to 6 keV). Also, the signal processing time was reduced to 0.6 μsec without seriously degrading the spatial resolution. These results have opened new fields of application of the RC position encoding method in imaging distributions of photons, charged particles, or neutrons in nuclear medicine, physics, and radiography

  14. Development of a lithium fluoride zinc sulfide based neutron multiplicity counter

    Science.gov (United States)

    Cowles, Christian; Behling, Spencer; Baldez, Phoenix; Folsom, Micah; Kouzes, Richard; Kukharev, Vladislav; Lintereur, Azaree; Robinson, Sean; Siciliano, Edward; Stave, Sean; Valdez, Patrick

    2018-04-01

    The feasibility of a full-scale lithium fluoride zinc sulfide (LiF/ZnS) based neutron multiplicity counter has been demonstrated. The counter was constructed of modular neutron detecting stacks that each contain five sheets of LiF/ZnS interleaved between six sheets of wavelength shifting plastic with a photomultiplier tube on each end. Twelve such detector stacks were placed around a sample chamber in a square arrangement with lithiated high-density polyethylene blocks in the corners to reflect high-energy neutrons and capture low-energy neutrons. The final system design was optimized via modeling and small-scale test. Measuring neutrons from a 252Cf source, the counter achieved a 36% neutron detection efficiency (ɛ) and an 11 . 7 μs neutron die-away time (τ) for a doubles figure-of-merit (ɛ2 / τ) of 109. This is the highest doubles figure-of-merit measured to-date for a 3He-free neutron multiplicity counter.

  15. Paid counter-advertising: proven strategy to combat tobacco use and promotion.

    Science.gov (United States)

    Blum, A

    1994-01-01

    This article discusses the effectiveness of paid counter-advertising in combating tobacco use and promotion, the impact of the Fairness Doctrine, which mandated anticigarette television advertisements in the late 1960s, and reasons why the media today are reluctant to run antismoking advertisements. Although counter-advertisements can work very well, they should be image-based, rather than fact-based. Currently, tobacco companies promote a positive image of cigarette smoking and brand awareness. Most antismoking ads, however, tend to focus on the tobacco itself and its adverse effects on the smoker, rather than combating the images the cigarette ads promote. Urging counter-advertising to focus on the product, rather than to try to produce guilt in smokers, this article provides examples of paid counter-advertising strategies employed by Doctors Ought to Care to illustrate an image-based approach. Overall, the antismoking movement must guard against complacency and measure its success according to tobacco companies' declining revenues, rather than the number of public service advertisements in the media.

  16. Counter-current acid leaching process for copper azole treated wood waste.

    Science.gov (United States)

    Janin, Amélie; Riche, Pauline; Blais, Jean-François; Mercier, Guy; Cooper, Paul; Morris, Paul

    2012-09-01

    This study explores the performance of a counter-current leaching process (CCLP) for copper extraction from copper azole treated wood waste for recycling of wood and copper. The leaching process uses three acid leaching steps with 0.1 M H2SO4 at 75degrees C and 15% slurry density followed by three rinses with water. Copper is recovered from the leachate using electrodeposition at 5 amperes (A) for 75 min. Ten counter-current remediation cycles were completed achieving > or = 94% copper extraction from the wood during the 10 cycles; 80-90% of the copper was recovered from the extract solution by electrodeposition. The counter-current leaching process reduced acid consumption by 86% and effluent discharge volume was 12 times lower compared with the same process without use of counter-current leaching. However, the reuse of leachates from one leaching step to another released dissolved organic carbon and caused its build-up in the early cycles.

  17. The Eros of Counter Education

    Science.gov (United States)

    Luzon, Pinhas

    2016-01-01

    Erotic Counter Education (ECE) is the educational position of the late Ilan Gur-Ze'ev. In ECE Gur-Ze'ev combines two opposing positions in the philosophy of education, one teleological and anti-utopian, the other teleological and utopian. In light of this unique combination, I ask what mediates between these two poles and suggest that the answer…

  18. The cognitive costs of the counter-stereotypic: gender, emotion, and social presence.

    Science.gov (United States)

    McCarty, Megan K; Kelly, Janice R; Williams, Kipling D

    2014-01-01

    We explored the concurrent and subsequent cognitive consequences of the experience of gender counter-stereotypic emotions. Participants experiencing gender counter-stereotypic emotions were expected to display less emotional expression and demonstrate poorer cognitive performance when in the public condition than when in the private condition. Seventy-one women and 66 men completed an anger- or sadness-inducing task privately or publicly. Participants completed two cognitive tasks: one during and one after the emotion-induction task. Participants exhibited poorer performance during and following gender counter-stereotypic emotions only in the public condition. Direct evidence for greater suppression of gender counter-stereotypic emotions in the public conditions was not obtained. These results suggest that the same public emotional events may be differentially cognitively depleting depending on one's gender, potentially contributing to the perpetuation of stereotypes.

  19. Radiation protection in the Czechoslovak nuclear power plants

    International Nuclear Information System (INIS)

    Singer, J.; Koc, J.; Hynek, J.; Trousil, J.

    1987-01-01

    The radiation monitoring by means of the central information system and of autonomous, portable and laboratory devices as well as a brief characteristic of the nuclear power plant radiation fields are described. The new personal dosimetric film and thermoluminescent badges and the method (including the block diagram) for personal dose evaluation are also introduced. Internal contamination monitoring is performed by means of a whole-body counter and excreta sample analysis. Monitoring the influence of effluents from nuclear power plants on environment in Czechoslovakia is based on significant radionuclide measurements in ventilation stacks and in the environment, also by means of the telemetric system, all in connection with mathematical models. (author)

  20. Can counter-stereotypes boost flexible thinking?

    NARCIS (Netherlands)

    Goclowska, M.A.; Crisp, R.J.; Labuschagne, K.

    2013-01-01

    To reduce prejudice psychologists design interventions requiring people to think of counter-stereotypes (i.e., people who defy stereotypic expectations—a strong woman, a Black President). Grounded in the idea that stereotypes constrain the ability to think flexibly, we propose that thinking of

  1. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  2. Calibration of the LDI/CDTN Whole Body Counter using three physical phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Paiva, F.G.; Fonseca, T.C.F. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dep. de Engenharia Nuclear; Mendes, B.M.; Silva, T.A. da; Lacerda, M.A.S.; Pinto, J.R.; Prates, S.; Filho, N.N.A., E-mail: fgpaiva92@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte/MG (Brazil); Dantas, A.L.A.; Dantas, B.M. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The Laboratory of Internal Dosimetry of the Center for Development of Nuclear Technology (LDI/CDTN) is responsible for routine monitoring of internal contamination of the Individuals Occupationally Exposed (IOEs) at the Unit for Research and Production of Radiopharmaceuticals (UPPR/CDTN), the Research Reactor TRIGA-IPR-R1/CDTN and other workplaces of the institute where there is a risk of accidental intakes. Additionally, LDI supports the Institute of Radiation Protection and Dosimetry (IRD/CNEN) to attend radiological emergencies. The determination of photon emitting radionuclides in the human body requires the use of calibration techniques in different counting geometries for converting the count rates into activity in organs and tissues. This paper presents and discusses the calibration of the LDI/CDTN Whole Body Counter (WBC) using a standard BOMAB phantom (Bottle Mannequin Absorber) compared to a home-made phantom produced with Polyethylene Terephthalate bottles (PET). Initially, the BOMAB was filled with a cocktail containing {sup 60}Co, {sup 137}Cs and {sup 133}Ba. The phantom was counted at the LDI whole body counter and an Efficiency x Energy curve was obtained. Subsequently the PET-BOMAB was filled with the same standard source and a second curve was determined. The efficiency values in each region of interest as well as the shape of both curves were found to be equivalent. The results validate the use of the PET-BOMAB for the calibration of whole body geometry applied to the measurement of high energy photon emitting radionuclides in the energy region evaluated in this work. (author)

  3. The Tax Evasion in Ukraine: Causes and Methods of Countering

    Directory of Open Access Journals (Sweden)

    Parfentii Liudmyla A.

    2018-03-01

    Full Text Available The essence of the concept of tax evasion is researched; reasons of occurrence and development of this phenomenon are analyzed; proposals on the main directions of prevention and countering tax evasion have been developed. Analyzing, systematizing and generalizing the scientific works of many scholars, it was found that there is no unified approach to interpretation of the essence of this phenomenon in the context of legality and awareness of relevant actions in the scientific literature. As a result of the research the factors of tax evasion with the allocation of moral, political, economic, technical, and legal reasons have been systematized. The preconditions of tax evasion in Ukraine are analyzed, the most common schemes are indicated, resulting from which the budget of Ukraine suffers the greatest losses. Methods of countering tax offenses have been researched and necessity of development and implementation of measures on prevention and countering tax evasion at the State level has been substantiated. Prospects for further researches in this direction are studying of foreign experience of countering tax evasion and detailed analyzing of the tax minimization schemes prevalent in Ukraine with the purpose of identifying ways of elimination of possibility of their use.

  4. Portable radiation meters developed in Boris Kidric Institute

    International Nuclear Information System (INIS)

    Sobajic, V.; Smelcerovic, M.

    1989-01-01

    Portable meters designed for X and gamma radiation measurements and beta detection are described. An instrument using ionization chamber is developed with new type of electrometer amplifier. It is designed for precise and reliable exposure and exposure rate measurements. Another instrument with GM counters covers 8 linear ranges: from background up to 10 Sv/h. Some specific solutions and basic measurement characteristics of these instruments are presented (author)

  5. Nano structural anodes for radiation detectors

    Science.gov (United States)

    Cordaro, Joseph V.; Serkiz, Steven M.; McWhorter, Christopher S.; Sexton, Lindsay T.; Retterer, Scott T.

    2015-07-07

    Anodes for proportional radiation counters and a process of making the anodes is provided. The nano-sized anodes when present within an anode array provide: significantly higher detection efficiencies due to the inherently higher electric field, are amenable to miniaturization, have low power requirements, and exhibit a small electromagnetic field signal. The nano-sized anodes with the incorporation of neutron absorbing elements (e.g., .sup.10B) allow the use of neutron detectors that do not use .sup.3He.

  6. Analysis of counter flow of corona wind for heat transfer enhancement

    Science.gov (United States)

    Shin, Dong Ho; Baek, Soo Hong; Ko, Han Seo

    2018-03-01

    A heat sink for cooling devices using the counter flow of a corona wind was developed in this study. Detailed information about the numerical investigations of forced convection using the corona wind was presented. The fins of the heat sink using the counter flow of a corona wind were also investigated. The corona wind generator with a wire-to-plate electrode arrangement was used for generating the counter flow to the fin. The compact and simple geometric characteristics of the corona wind generator facilitate the application of the heat sink using the counter flow, demonstrating the heat sink is effective for cooling electronic devices. Parametric studies were performed to analyze the effect of the counter flow on the fins. Also, the velocity and temperature were measured experimentally for the test mock-up of the heat sink with the corona wind generator to verify the numerical results. From a numerical study, the type of fin and its optimal height, length, and pitch were suggested for various heat fluxes. In addition, the correlations to calculate the mass of the developed heat sink and its cooling performance in terms of the heat transfer coefficient were derived. Finally, the cooling efficiencies corresponding to the mass, applied power, total size, and noise of the devices were compared with the existing commercial central processing unit (CPU) cooling devices with rotor fans. As a result, it was confirmed that the heat sink using the counter flow of the corona wind showed appropriate efficiencies for cooling electronic devices, and is a suitable replacement for the existing cooling device for high power electronics.

  7. A proposal to use microstrip gas counters in a LHC tracker

    International Nuclear Information System (INIS)

    Geijsberts, M.; Hartjes, F.G.; Pannekoek, J.G.; Schmitz, J.; Udo, F.

    1991-06-01

    The paper presents an LHC tracker constructed from microstrip gas counters, occupying a cylinder around the beam r=400 mm and r=900 mm. The instrument measures 12 points on track with an accuracy of 30μm. Due to fine granularity and the short charge collection time, the occupancy is below 1 percent at a luminosity of L=10 34 cm -2 . Operating at high magnetic fields and a fast charge collection process are possible using Xe/DME/CO 2 mixtures and reducing the gap width between substrate and drift cathode to 1.6 mm. Hits from low energetic tracks are largely suppressed and hard tracks stand out, which greatly facilitates pattern recognition. By introducing a small stereo angle, the (r,z) coordinate can be measured with an accuracy of 1 mm. A calculation of the collected charge per strip shows that the tracker can withstand the LHC radiation for many years. (author). 9 refs.; 7 figs

  8. A new neutron counter for fission research

    Energy Technology Data Exchange (ETDEWEB)

    Laurent, B., E-mail: benoit.laurent@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Granier, T.; Bélier, G.; Chatillon, A.; Martin, J.-F.; Taieb, J. [CEA, DAM, DIF, F-91297 Arpajon (France); Hambsch, F.-J. [EC-JRC Institute for Reference Materials and Measurements (IRMM), Retieseweg, 2440 Geel (Belgium); Tovesson, F.; Laptev, A.B.; Haight, R.C.; Nelson, R.O.; O' Donnell, J.M. [Los Alamos Neutron Science Center, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2014-05-01

    A new neutron counter for research experiments on nuclear fission has been developed. This instrument is designed for the detection of prompt fission neutrons within relatively high levels of gamma and neutron background. It is composed of a set of {sup 3}He proportional counters arranged within a block of polyethylene which serves as moderator. The detection properties have been studied by means of Monte Carlo simulations and experiments with radioactive sources. These properties are confirmed by an experiment on neutron-induced fission of {sup 238}U at the WNR facility of the Los Alamos Neutron Science Center during which the mean prompt fission neutron multiplicity, or ν{sup ¯} has been measured from 1 to 20 MeV of incident neutron energy.

  9. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  10. Very large area multiwire spectroscopic proportional counters

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F.

    1981-01-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) succesfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm 2 with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results. (orig.)

  11. Very large area multiwire spectroscopic proportional counters

    Energy Technology Data Exchange (ETDEWEB)

    Ubertini, P.; Bazzano, A.; Boccaccini, L.; Mastropietro, M.; La Padula, C.D.; Patriarca, R.; Polcaro, V.F. (Istituto di Astrofisica Spaziale, Frascati (Italy))

    1981-07-01

    As a result of a five year development program, a final prototype of a Very Large Area Spectroscopic Proportional Counter (VLASPC), to be employed in space borne payloads, was produced at the Istituto di Astrofisica Spaziale, Frascati. The instrument is the last version of a new generation of Multiwire Spectroscopic Proportional Counters (MWSPC) successfully employed in many balloon borne flights, devoted to hard X-ray astronomy. The sensitive area of this standard unit is 2700 cm/sup 2/ with an efficiency higher than 10% in the range 15-180 keV (80% at 60 keV). The low cost and weight make this new type of VLASPC competitive with Nal arrays, phoswich and GSPC detectors in terms of achievable scientific results.

  12. Standardization of calibration method of whole-body counter. 1. Calibration by using anthropometric phantoms

    International Nuclear Information System (INIS)

    Ishikawa, Tetsuo; Matsumoto, Masaki; Uchiyama, Masafumi; Kobayashi, Sadayoshi; Mizushita, Seiichi.

    1995-01-01

    To standardize the calibration methods of whole-body counters, three anthropometric phantoms were manufactured based on dozens of Japanese average value of body size data. Using these phantoms, the calibrations of some whole-body counters were carried out and the comparison of counting efficiency between anthropometric phantoms and block phantoms, which used to be used for the calibration of whole-body counters generally, was implemented. Five whole-body counters, one scanning system, two stationary systems and two chair systems, were used for this study. The following results were derived: As an example, in NIRS scanning system, the counting efficiency of anthropometric phantom of 162cm height was 12.7% greater than that of block phantom of the same height. This means 137 Cs body burdens in adult men used to be estimated with the excess of about 10%. Body burdens tended to be estimated excessively in adult because the difference of counting efficiency between anthropometric phantom and block phantom increases with increase of height. To standardize body burden data measured with various whole-body counters, the calibration of each whole-body counter should be conducted using anthropometric phantoms and phantoms which used to be used for the calibration of that whole-body counter. (author)

  13. Evaluation of in-plant neutron coincidence counters for the measurement of molten salt extraction residues

    International Nuclear Information System (INIS)

    Langner, D.G.; Russo, P.A.; Wachter, J.R.

    1993-01-01

    Americium is extracted from plutonium by a molten salt extraction (MSE) process. The residual americium-laden salts are a significant waste stream in this pyrochemical purification process. Rapid assay of MSE residues is desirable to minimize the exposure of personnel to these often high-level emissions. However, the quantitative assay of plutonium in MSE residues is difficult. Variable, unknown (a,n) rates and variable emitted-neutron energy spectra preclude the use of standard neutron coincidence counting techniques with old-generation neutron coincidence counters. Gamma-ray assay methods have not been successful with some residues because of random lumps of plutonium metal. In this paper, we present measurements of MSE residues with two state-of-the-art neutron coincidence counters at the Los Alamos Plutonium Processing Facility: an in-line counter built for the assay of bulk waste material and the pyrochemical multiplicity counter that underwent test and evaluation at that facility. Both of these counters were designed to minimize the effects on measurements of variations in the sample geometry and variable energy spectra of emitted neutrons. These results are compared to measurements made with an HLNCII and with a 20-yr-old in-line well counter. The latter two counters are not optimized in ft sense. We conclude that the newer counters provide significantly improved assay results. The pyrochemical multiplicity counter operated in the conventional coincidence mode provided the best assays overall

  14. Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown.

    Science.gov (United States)

    Lum, Cynthia; Kennedy, Leslie W; Sherley, Alison

    2008-02-01

    Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown. One of the central concerns surrounding counter-terrorism interventions today, given the attention and money spent on them, is whether such interventions are effective. To explore this issue, we conducted a general review of terrorism literature as well as a Campbell systematic review on counter-terrorism strategies. In this article, we summarize some of our findings from these works. Overall, we found an almost complete absence of evaluation research on counter-terrorism strategies and conclude that counter-terrorism policy is not evidence-based. The findings of this review emphasise the need for government leaders, policy makers, researchers, and funding agencies to include and insist on evaluations of the effectiveness of these programs in their agendas.

  15. Timecourse of mirror and counter-mirror effects measured with transcranial magnetic stimulation.

    Science.gov (United States)

    Cavallo, Andrea; Heyes, Cecilia; Becchio, Cristina; Bird, Geoffrey; Catmur, Caroline

    2014-08-01

    The human mirror system has been the subject of much research over the past two decades, but little is known about the timecourse of mirror responses. In addition, it is unclear whether mirror and counter-mirror effects follow the same timecourse. We used single-pulse transcranial magnetic stimulation to investigate the timecourse of mirror and counter-mirror responses in the human brain. Experiment 1 demonstrated that mirror responses can be measured from around 200 ms after observed action onset. Experiment 2 demonstrated significant effects of counter-mirror sensorimotor training at all timepoints at which a mirror response was found in Experiment 1 (i.e. from 200 ms onward), indicating that mirror and counter-mirror responses follow the same timecourse. By suggesting similarly direct routes for mirror and counter-mirror responses, these results support the associative account of mirror neuron origins whereby mirror responses arise as a result of correlated sensorimotor experience during development. More generally, they contribute to theorizing regarding mirror neuron function by providing some constraints on how quickly mirror responses can influence social cognition. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  16. Impact of the probability of causation on the radiation protection program

    International Nuclear Information System (INIS)

    Meinhold, C.B.

    1988-01-01

    Although the probability of causation approach is the only scientific basis on which a given cancer can be judged to be causally related to a given exposure, the impact of this concept on the radiation safety program could be counter-productive. As health physicists, the practices and the concepts we employ have been developed to protect the worker. Effective dose equivalent and committed dose equivalent are protective concepts but useless for probability of causation analysis. Perhaps extensive records will be the only way that good radiation protection and probability of causation analysis can coexist

  17. Counter-Chemical, Biological, Radiological, and Nuclear Operations

    National Research Council Canada - National Science Library

    2007-01-01

    ..., with little or no warning. Success in defending our nation, our military forces, and partners and allies depends on how effectively we apply air, space, and cyberspace power to counter this threat...

  18. Absolute measurement of the activity of 222Rn using a proportional counter

    International Nuclear Information System (INIS)

    Busch, Ingo; Greupner, Heinz; Keyser, Uwe

    2002-01-01

    A measuring set-up comprising a proportional counter of calculable 222 Rn efficiency and quantifiable active volume (δ V 222 Rn efficiency is determined by computer simulation of the measured α-spectra. The procedures necessary for absolute measurements by means of the counter are described, and the suitability of the counter for absolute measurements of the 222 Rn activity is proved by experiments. Thus, a new method for the realization of the unit of activity of 222 Rn is obtained, which is independent of the unit of activity of 226 Ra

  19. Radiation biodosimetry: Applications for spaceflight

    Science.gov (United States)

    Blakely, W. F.; Miller, A. C.; Grace, M. B.; McLeland, C. B.; Luo, L.; Muderhwa, J. M.; Miner, V. L.; Prasanna, P. G. S.

    The multiparametric dosimetry system that we are developing for medical radiological defense applications could be adapted for spaceflight environments. The system complements the internationally accepted personnel dosimeters and cytogenetic analysis of chromosome aberrations, considered the best means of documenting radiation doses for health records. Our system consists of a portable hematology analyzer, molecular biodosimetry using nucleic acid and antigen-based diagnostic equipment, and a dose assessment management software application. A dry-capillary tube reagent-based centrifuge blood cell counter (QBC Autoread Plus, Beckon Dickinson Bioscience) measures peripheral blood lymphocytes and monocytes, which could determine radiation dose based on the kinetics of blood cell depletion. Molecular biomarkers for ionizing radiation exposure (gene expression changes, blood proteins) can be measured in real time using such diagnostic detection technologies as miniaturized nucleic acid sequences and antigen-based biosensors, but they require validation of dose-dependent targets and development of optimized protocols and analysis systems. The Biodosimetry Assessment Tool, a software application, calculates radiation dose based on a patient's physical signs and symptoms and blood cell count analysis. It also annotates location of personnel dosimeters, displays a summary of a patient's dosimetric information to healthcare professionals, and archives the data for further use. These radiation assessment diagnostic technologies can have dual-use applications supporting general medical-related care.

  20. Over-the-counter medications containing diphenhydramine and doxylamine used by older adults to improve sleep.

    Science.gov (United States)

    Abraham, Olufunmilola; Schleiden, Loren; Albert, Steven M

    2017-08-01

    Background The unintentional misuse of over-the-counter sleep aids among older adults is an important public health problem and a focus of Healthy People 2020. Accordingly, the 2015 Beers Criteria for Potentially Inappropriate Medication Use in Older Adults recommends that individuals 65 years or older avoid use of diphenhydramine and doxylamine; however, many over-the-counter sleep products contain these active ingredients. Objective To identify the proportion of older adults using an over-the-counter medication containing diphenhydramine or doxylamine, and compare their characteristics with older adults using an over-the-counter medication that does not contain these ingredients. Setting Study participants were recruited from the Community Registry of the Pittsburgh Claude D. Pepper Older Americans Independence Center. Method The study sample was taken from a larger survey of 1025 participants on sleep health and over-the-counter sleep medication use conducted from February to April 2015. A subset of 169 participants aged 65 and older reporting taking at least one over-the-counter product to improve sleep within the past 30 days (16.5%) were selected for our analysis on associations between participant characteristics and potentially inappropriate use of over-the-counter sleep medications. Main outcome measure The proportion and characteristics of older adults taking at least one over-the-counter medication containing diphenhydramine or doxylamine. Results Of the 223 over-the-counter sleep medications listed by participants, 115 (52%) contained diphenhydramine or doxylamine. Using the Beers Criteria, we found that more than half of participants (59%) had used a potentially inappropriate over-the-counter medication containing diphenhydramine or doxylamine to improve sleep within the past 30 days. Participants taking at least one diphenhydramine or doxylamine containing medication were less likely to be aware of any safety risks in taking over-the-counter sleep

  1. Project and construction of a measurement system and nuclear radiations analysis

    International Nuclear Information System (INIS)

    Castro, R. B. de.

    1983-01-01

    A counting system was designed and built, aiming to: detect and measure nuclear radiations using a Geiger-Mueller counter; and to measure the amplitudes of pulses from either a proportional or a NaI detector. The results obtained of the Cs-137 and Co-60 energy spectra were compared with results obtained from other researches. (Author) [pt

  2. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  3. Proportional counter response calculations for gallium solar neutrino detectors

    International Nuclear Information System (INIS)

    Kouzes, R.T.; Reynolds, D.

    1989-01-01

    Gallium bases solar neutrino detectors are sensitive to the primary pp reaction in the sun. Two experiments using gallium, SAGE in the Soviet Union and GALLEX in Europe, are under construction and will produce data by 1989. The radioactive /sup 71/Ge produced by neutrinos interacting with the gallium detector material, is chemically extracted and counted in miniature proportional counters. A number of calculations have been carried out to simulate the response of these counters to the decay of /sup 71/Ge and to background events

  4. E143 experiment. Shower counter calibration

    International Nuclear Information System (INIS)

    Fonvieille, H.; Grenier, P.

    1994-01-01

    The calibration procedure for the shower counters used in the E143 experiment is described. It has been developed during january 1994 in view of being used for the quick analysis. The method is explained and the results obtained on a given run are presented. (author)

  5. On the counting rate-dependent amplitude shifts in proportional counters

    International Nuclear Information System (INIS)

    Mahesh, K.

    1976-01-01

    The presence of a positive ion cloud near the anode wire, which has been believed to be the cause of the observed counting rate-dependent peak shifts in proportional counters, does not explain various exhibited features of these shifts. The possibility of other mechanisms involved is, therefore, examined. The columnar recombination of primary ions in the counter is considered to explain the origin of the shifts and their observed features. (Auth.)

  6. Searching for Orphan radiation sources

    International Nuclear Information System (INIS)

    Bystrov, Evgenij; Antonau, Uladzimir; Gurinovich, Uladzimir; Kazhamiakin, Valery; Petrov, Vitaly; Shulhovich, Heorhi; Tischenko, Siarhei

    2008-01-01

    Full text: The problem of orphan sources cannot be left unaddressed due high probability of accidental exposure and use of sources for terrorism. Search of objects of this kind is complex particularly when search territory is large. This requires devices capable of detecting sources, identifying their radionuclide composition, and correlating scan results to geographical coordinates and displaying results on a map. Spectral radiation scanner AT6101C can fulfill the objective of search for gamma and neutron radiation sources, radionuclide composition identification, correlation results to geographical coordinates and displaying results on a map. The scanner consists of gamma radiation scintillation detection unit based on NaI(Tl) crystal, neutron detection unit based on two He 3 counters, GPS receiver and portable ruggedized computer. Built-in and application software automates entire scan process, saving all results to memory for further analysis with visual representation of results as spectral information diagrams, count rate profile and gamma radiation dose rates on a geographical map. The scanner informs operator with voice messages on detection of radiation sources, identification result and other events. Scanner detection units and accessories are packed in a backpack. Weighing 7 kg, the scanner is human portable and can be used for scan inside cars. The scanner can also be used for radiation mapping and inspections. (author)

  7. Development of a parallel plate proportional counter TRD with suppressed sensitivity to ionization

    International Nuclear Information System (INIS)

    Solomey, N.; Krolak, P.; Graham, G.

    1995-01-01

    The development of a Parallel Plate Proportional Counter which has a highly suppressed sensitivity to ionization but retains a good X-ray signal to noise ratio is presented. Details of the laboratory development and actual beam tests showing the e/π rejection are described. Because of its insensitivity to ionization this type of detector can be useful in an environment where the number of minimum ionizing particles are high, but uninteresting; however, the detector is very sensitive to the highly localized electron cloud from converted X-rays making it ideal as a transition radiation X-ray detector. Thus, this detector only gives a signal for charged particles above TR threshold; all other particles below this threshold produce no TR X-rays giving only a pedestal-like signal. The system's potential performance for π/p separation in the intended neutral Hyperon experiment is evaluated

  8. Gramscian ‘Counter hegemony’ in Narendra Modi’s New India Perspective

    Directory of Open Access Journals (Sweden)

    Venkat Rao Pulla

    2017-03-01

    Full Text Available The counter hegemony   that Gramsci, (1987:344 talks about is about leaders and their understanding and how well they conceptualise the psychology of the masses. Counter hegemonies have transformative power and Modi continues to prove that. In this special editorial, the author reviews the leadership of Mr Modi in India.

  9. Studies at LBL's Bevalac will help resolve uncertainties about radiation risks to astronauts

    International Nuclear Information System (INIS)

    Kahn, J.

    1991-01-01

    Plans to operate the LBL's Bevalac facility for space research are discussed. The proposed program includes the use of cell cultures and animal models to assess the biological consequences of exposures to different particles that are components of the space radiation environment. Research will also be conducted on measures to counter radiation. Experiments will be carried out to examine how various materials that could be used in a spacecraft wall would alter the cascade of particles that would ultimately reach an astronaut

  10. Evaluation of fat-free mass by whole-body counter in Japanese healthy young adults

    International Nuclear Information System (INIS)

    Morita, N.; Takamura, N.; Murakami, T.; Jo, O.; Aoyagi, K.; Yamashita, S.; Okumura, Y.

    2007-01-01

    Whole-body counters (WBCs) are special instruments for measuring internal irradiation doses and are usually housed within or around nuclear facilities in the event of unexpected radiation emergencies. As a substantial proportion of total body potassium (TBK) is found in fat-free mass (FFM), FFM volume can be predicted from WBC-measured 40 K. We screened TBK in Japanese healthy young adults using a WBC and found strong linear correlations between TBK and lean body mass (LBM) and body mass index (r = 0.97, P<0.01 and r = 0.47, P<0.01, respectively). Multiple linear regression analysis, following adjustments for sex, indicates that only LBM has a significant correlation with TBK (P<0.01). These results strongly support the feasibility of using WBCs for estimating FFM. (authors)

  11. Al Qaeda’s “Single Narrative” and Attempts to Develop Counter-Narratives

    Directory of Open Access Journals (Sweden)

    Alex P. Schmid

    2014-01-01

    Full Text Available In this Research Paper, Research Fellow Dr. Alex Schmid dissects the nature of Al Qaeda’s propaganda strategy by looking how it incorporates in its ideological narrative Islam’s sacred texts and traditions and how it manages to link these to widespread contemporary grievances in the Muslim world. Al Qaeda’s survival is tied to the credibility of its narrative “story” rather than the physical survival of its leadership. The Research Paper discusses mainly American and British efforts to challenge the integrative (hence: “single” narrative of Al Qaeda. Current counter-narratives often fall short of reaching objectives due to a lack of credibility – a result of the gap between official Western declaratory policies and actual policies on the ground. Efforts to sell “hearts and minds” products often floundered on policies that lack legitimacy or stood in stark contrast to professed values like adherence to human rights standards, thereby creating perceptions of double standards and hypocrisy. While Al Qaeda’s policies exhibit similar, and in some areas even greater, discrepancies between what is being said and what is being done, these have not been fully exploited. Following the discussion of governmental efforts to counter Al Qaeda’s narrative, findings and suggestions from academia, think tanks, religious scholars and others trying to counter Al Qaeda’s narrative are presented. While it is generally true that counter-narrative work is still in its infancy, the survey of various proposals and programs makes clear that important building blocks for a more creative effort of countering the ideological attraction of Al Qaeda exist. One of the problems with counter-narratives is their defensive and reactive nature and their focus on packaging messages. This paper emphasises the importance of crafting and spreading an alternative narrative. While counter-narratives have to aim at discrediting the exclusive narrative of Al Qaeda

  12. The effects of gender stereotypic and counter-stereotypic textbook images on science performance.

    Science.gov (United States)

    Good, Jessica J; Woodzicka, Julie A; Wingfield, Lylan C

    2010-01-01

    We investigated the effect of gender stereotypic and counter-stereotypic images on male and female high school students' science comprehension and anxiety. We predicted stereotypic images to induce stereotype threat in females and impair science performance. Counter-stereotypic images were predicted to alleviate threat and enhance female performance. Students read one of three chemistry lessons, each containing the same text, with photograph content varied according to stereotype condition. Participants then completed a comprehension test and anxiety measure. Results indicate that female students had higher comprehension after viewing counter-stereotypic images (female scientists) than after viewing stereotypic images (male scientists). Male students had higher comprehension after viewing stereotypic images than after viewing counter-stereotypic images. Implications for alleviating the gender gap in science achievement are discussed.

  13. Informational and symbolic content of over-the-counter drug advertising on television.

    Science.gov (United States)

    Tsao, J C

    1997-01-01

    The informational and symbolic content of 150 over-the-counter drug commercials on television are empirically analyzed in this study. Results on the informational content suggest that over-the-counter drug ads tend to focus on the concern of what the drug will do for the consumer, rather than on the reasons why the drug should be ingested. Accordingly, advertising strategy is centered on consumer awareness of the product as the primary goal. Educational commitment, however, did not seem to be blended into the promotional efforts for over-the-counter drugs. Findings on the symbolic content of over-the-counter drug ads reveal that drug images have been distorted. Performance of most drugs has been portrayed to be simple resolutions to relieve the symptom. Moreover, a casual attitude toward drug usage is encouraged in the commercials, while time lapse of drug effects is overlooked.

  14. Electromagnetic shower counter

    CERN Multimedia

    CERN PhotoLab

    1974-01-01

    The octogonal block of lead glass is observed by eight photomultiplier tubes. Four or five such counters, arranged in succession, are used on each arm of the bispectrometer in order to detect heavy particles of the same family as those recently observed at Brookhaven and SLAC. They provide a means of identifying electrons. The arrangement of eight lateral photomultiplier tubes offers an efficient means of collecting the photons produced in the showers and determining, with a high resolution, the energy of the incident electrons. The total width at half-height is less than 6.9% for electrons having an energy of 1 GeV.

  15. 26 CFR 1.1092(c)-3 - Qualifying over-the-counter options.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Qualifying over-the-counter options. 1.1092(c)-3...-counter options. (a) In general. Under section 1092(c)(4)(B)(i), an equity option is not a qualified covered call option unless it is traded on a national securities exchange that is registered with the...

  16. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  17. Counter-Democratic Surveillance: The Watchful Eye of a Local Institution

    DEFF Research Database (Denmark)

    Hjelholt, Morten

    2014-01-01

    mechanisms similar to those described by Foucault, but in the service of society. From this perspective democracy is seen as a composite of two realms – a sphere of electoral representation and a constellation of counter-democratic organizations – in constant tension with each other (Rosanvallon 2008......). The watchful eyes of counter-democratic organizations are particularly made powerful by the rise of the Internet with its spontaneous adaption of watchful functions. However increased awareness and mistrust have led not to broader participation in traditional liberal institutions but to a greater social...... in the interest of the national overseers but correspondingly given as responds to fulfill legal requirements or more loosely defined public concerns. Consequently the watchful eye of a local institution form a counter-democratic sight aimed at the strategic intentions of the Government. The paper introduces...

  18. Resonance detection of Moessbauer radiation

    International Nuclear Information System (INIS)

    Morozov, V.V.

    1985-01-01

    The resonance detection method as compared with the usual method of registering Moessbauer spectra has a number of advantages, one of which is the increase of resolution of the Moessbauer spectrum. The method is based on the modulation of a secondary radiation of a converter tuned in the resonance with the Moessbauer gamma-quantum source. The resonance detection method with account of supression, secondary radiation outgoing from the converter is investigated. The converter represents a substrate enriched by the Moessbauer isotope placed either inside the gas counter, or coupled with any other detecting device. Analytical expressions for Moessbauer spectrum parameters: effect, area and width of the spectral line are derived. It is shown that the joint application of usual and resonance detection methods for registering the Moessbauer spectrum allows one to determine parameters of the source, converter and the investigated absorber

  19. Search for an optimum time response of spark counters

    International Nuclear Information System (INIS)

    Devismes, A.; Finck, Ch.; Kress, T.; Gobbi, A.; Eschke, J.; Herrmann, N.; Hildenbrand, K.D.; Koczon, P.; Petrovici, M.

    2002-01-01

    A spark counter of the type developed by Pestov has been tested with the aim of searching for an optimum time response function, changing voltage, content of noble and quencher gases, pressure and energy-loss. Replacing the usual argon by neon has brought an improvement of the resolution and a significant reduction of tails in the time response function. It has been proven that a counter as long as 90 cm can deliver, using neon gas mixture, a time resolution σ<60 ps with about 1% absolute tail and an efficiency of about 90%

  20. Gas scintillation proportional counters for x-ray synchrotron applications

    International Nuclear Information System (INIS)

    Smith, A.; Bavdaz, M.

    1992-01-01

    Gas scintillation proportional counters (GSPCs) as x-ray detectors provide some advantages and disadvantages compared with proportional counters. In this paper the various configurations of xenon filled GSPC are described including both imaging and nonimaging devices. It is intended that this work be used to configure a GSPC for a particular application and predict its general performance characteristics. The general principles of operation are described and the performance characteristics are then separately considered. A high performance, imaging, driftless GSPC is described in which a single intermediate window is used between the PMT and gas cell

  1. Proportional counter with uniform electric field with Penning's mixture

    International Nuclear Information System (INIS)

    Pawlowski, Z.; Marzec, J.; Zaremba, K.

    1984-01-01

    Some calculations are given and the design of proportional counters with a homogeneous electric field filled with Penning's mixtures, which ensure the best energy resolution is described. The counters with mixtures of Ne+Ar, Ne+CH 4 , Ne+CO 2 and Ar+C 2 H 2 have been checked. The admixtures (Ar, CH 4 , CO 2 , C 2 H 2 ) constitute from 0.1 to 2%, with pressure from 125 Tr to 760 Torr. The best energy resolution has been obtained for the mixture of Ne+1%CH 4 at the pressure of 190 Torr

  2. Pre-criticality testing of radiation monitors associated with protective and regulatory channels of PHWRs and related work

    International Nuclear Information System (INIS)

    Tripathi, S.M.; Rao, Suresh; Mahant, A.K.; Sathian, V.; Ghodke, Shobha; Satam, R.A.; Singh, Yashoda; Phadnis, U.V.; Shaha, V.V.

    2006-01-01

    The paper describes the various experiments that are regularly carried out for each PHWR since RAPS-2. The work involves performance evaluation of start-up counters and ion chambers used in Protective and Regulatory channels and start-up counters used both in-core and out of core. In addition, Radiation Safety Systems Division (RSSD) also carries out calibration of Delayed Neutron Monitors (DNM) and Self Powered Neutron Detectors (SPND). Except SPND, all other detectors are tested not only at BARC but also at reactor sites prior to initial flushing of heavy water, using the actual circuitry and control instruments at site. The performance evaluation of SPNDs is carried out at A-1 location of APSARA reactor core. Apart from these, RSSD also carries out calibration of zonal classification monitors and health physics related radiation monitors at BARC. (author)

  3. Space-charge effects of the proportional counters in a multiple-ionization chamber

    International Nuclear Information System (INIS)

    Mang, M.

    1993-01-01

    At the ALADIN spectrometer of the GSI in october 1991 for the first time the new multiple ionization chamber was applied, in the two anode planes of which are additional multiwire-proportional counters. The proportional counters are required in order to make the detection of light fragments (Z 4 gold projectiles per second by these positive space charges the homogeneous electric field of the MUSIC is disturbed. This effect is especially strong in the beam plane. As consequence of the space charge additionally electrons are focused on the proportional counter so that their amplitudes in dependence on the beam intensity increase up to the 2.5-fold. Furthermore the y coordinate is falsified, because the electrons are diverted to the medium plane. On the measurement of the x coordinate this diversion has with maximally 0.1% only a small influence. These space-charge effects can be qualitatively described by a schematic model, which assumes a stationary positive space charge. Additionally for the proportional counters, which are not in the beam plane, their resolution was determined. In these counters the space-charge effects are small, because essentially fewer particles are registrated than in the medium MWPC's. By this charges of fragments with Z<10 could be separated. The charge resolution amounted at lithium 0.8 charge units. The position resolution of the proportional counters in y direction was determined to less than 8 mm. The detection probability of the fragments amounts for lithium 90% and from boron all fragments are detected

  4. SiPM as photon counter for Cherenkov detectors

    International Nuclear Information System (INIS)

    Roy, B.J.; Orth, H.; Schwarz, C.; Wilms, A.; Peters, K.

    2009-01-01

    Silicon photomultipliers (SiPMs) are very new type of photon counting devices that show great promise to be used as detection device in combination with scintillators/ Cherenkov radiators. SiPM is essentially an avalanche photo-diode operated in limited Geiger mode. They have been considered as potential readout devices for DIRC counter of the PANDA detector which is one of the large experiment at FAIR- the new international facility to be built at GSI, Darmstadt. In addition, the potential use of SiPM includes medical diagnosis, fluorescence measurement and high energy physics experiments. The SiPM module is a photon counting device capable of low light level detection. It is essentially an opto-semiconductor device with excellent photon counting capability and possesses great advantages over the conventional PMTs because of low voltage operation and insensitivity to magnetic fields. In many of the high energy physics experiments, the photon sensors are required to operate in high magnetic fields precluding the use of conventional PMTs. This problem can be over come with the use of SiPMs. With this motivation in mind, we have developed a SiPM test facility and have tested several commercially available SiPM for their performance study and comparison with other photon counting devices

  5. Fast differential pulse discriminator-counter

    International Nuclear Information System (INIS)

    Shelevoj, K.D.

    1985-01-01

    The flowsheet of a differential pulse discriminator counter is described; the result of discrimination here is independent from the shape of the input pulse. Rate of the analysis of input pulses with minimum amplitude up to 0.3 mV coming out from the photomultiplier makes up 220 MHz. The flowsheet of the discriminator used in the system of photon counting for atmosphere probing is presented

  6. A freeze-dried graphene counter electrode enhances the performance of dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Kai-Hsiang; Wang, Hong-Wen, E-mail: hongwen@cycu.edu.tw

    2014-01-01

    A flexible graphene/polyimide (PI) counter electrode without a fluorine-doped tin oxide (FTO) layer has been fabricated for dye-sensitized solar cell (DSSCs) applications. The flexible counter electrode consists of polyimide double-sided tape as a substrate beneath a graphene film acting as the conductive and catalytic layer. Chemically reduced graphene oxide (rGO) on the PI electrode (rGO-PI) shows comparable catalytic activity to that of the reference sputtered platinum/FTO counter electrodes (Sputter-Pt/FTO). A DSSC with a freeze-dried rGO-PI (FD-rGO-PI) counter electrode shows an overall conversion efficiency (η) of 5.45%, while that of the conventional Sputter-Pt/FTO electrode is 5.52%. The DSSC with a thermally dried rGO-PI (Gel-rGO-PI) counter electrode (not freeze-dried) exhibits a smooth morphology and much poorer performance (η = 1.61%). Field emission scanning electron microscopy, electrochemical impedance spectroscopy, and cyclic voltammetry measurements demonstrate that the FD-rGO-PI electrode possesses a porous structure, numerous edges, minimum charge-transfer resistance and a higher electrocatalytic activity toward the I{sub 3}{sup −}/I{sup −} redox couple than that of the Gel-rGO-PI electrode. The high electrocatalytic activity, facile preparation procedure, absence of FTO, and material flexibility render the FD-rGO-PI electrode an ideal alternative to conventional DSSC counter electrodes. - Highlights: • Highly rough and conductive graphene-based counter electrode is synthesized. • The characteristics of graphene surface by freeze drying are different. • The graphene counter electrode exhibits comparable performance to that of sputtered Pt one.

  7. Radiation measured for ISS-Expedition 12 with different dosimeters

    International Nuclear Information System (INIS)

    Zhou, D.; Semones, E.; Gaza, R.; Johnson, S.; Zapp, N.; Weyland, M.

    2007-01-01

    Radiation in low Earth orbit (LEO) is mainly from Galactic Cosmic Rays (GCR), solar energetic particles and particles in South Atlantic Anomaly (SAA). These particles' radiation impact to astronauts depends strongly on the particles' linear energy transfer (LET) and is dominated by high LET radiation. It is important to investigate the LET spectrum for the radiation field and the influence of radiation on astronauts. At present, the best active dosimeters used for all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors; the best passive dosimeters are thermoluminescence dosimeters (TLDs) or optically stimulated luminescence dosimeters (OSLDs) for low LET and CR-39 plastic nuclear track detectors (PNTDs) for high LET. TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation for space mission Expedition 12 (ISS-11S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the mission with these different dosimeters. This paper introduces the operation principles for these dosimeters, describes the method to combine the results measured by CR-39 PNTDs and TLDs/OSLDs, presents the experimental LET spectra and the radiation quantities

  8. The side-on response of a standard long counter to fast neutrons

    International Nuclear Information System (INIS)

    Johnson, F.A.

    1979-01-01

    The response of a standard long counter to neutrons incident into its front face relative to its response to those incident into its side was measured for a range of neutron energies, and an increasing sensitivity to high-energy neutrons incident into the side was evident. The effect of a shadow bar in contributing to an initial degradation in energy of neutrons which then scatter from the surroundings into the counter was suggested by the response of the counter in the side-on orientation as a function of the separation distance of the bar from a source. (Auth.)

  9. Radiation protection measures in case of 125I incorporation

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    Thyroid measurements were performed on members of the scientific staff in the whole body counter of the Giessen Radiation Center with an aluminium encapsulated 3'' x 3'' dia. NaI(T1) detector; the personnel under investigation comprised those persons who either handled major quantities of 125 I or worked in the controlled area. The measuring setup, phantom calibration and the limits of measurement that can be attained are discussed. In a few cases of incorporation the effective halflife was determined. The radiation exposure was calculated by the absorbed fractions concept. A hazard is encountered almost exclusively in the iodization of the test substances. (orig./HP) [de

  10. Online De-Radicalization? Countering Violent Extremist Narratives: Message, Messenger and Media Strategy

    Directory of Open Access Journals (Sweden)

    Omar Ashour

    2011-01-01

    Full Text Available Is “online de-radicalization” possible? Given the two growing phenomena of “online radicalization” and “behavioral/ideological/organizational de-radicalization,” this article outlines a broad strategy for countering the narratives of violent extremists. It argues that an effective counter-narrative should be built on three pillars. The first is an effective comprehensive message that dismantles and counter-argues against every dimension of the extremist narrative, namely the theological, political, historical, instrumental and socio-psychological dimensions. The second pillar is the messengers. The article argues that for the first time in the history of Jihadism a “critical mass” of former militants, who rebelled not only against the current behaviour of their former colleagues but also against the ideology supporting it, has come into existence. This “critical mass” can constitute the core of credible messengers, especially the few de-radicalized individuals and groups that still maintain influence and respect among vulnerable communities. The third pillar is the dissemination and attraction strategy of the counter-narratives(s which focuses on the role of the media. The author of the article outlines a broad framework, which is a part of a UN-sponsored, comprehensive research project on countering the extremists narrative.

  11. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    International Nuclear Information System (INIS)

    Marzec, J.; Pawlowski, Z.

    1982-01-01

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO 2 , Ne+CH 4 and Ar+C 2 H 2 , much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH 4 , a resolution of fwhm=10.5% has been obtained for E=5.9 keV. (orig.)

  12. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    Science.gov (United States)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  13. Occupational radiation exposure in the GDR in 1978

    International Nuclear Information System (INIS)

    Poulheim, K.F.; Rothe, W.; Scheler, R.

    1980-01-01

    In 1978, radiation workers were monitored for external and internal radiation exposure on the basis of film badges (37,980 persons), measurements with a whole-body counter (186 persons) and analyses of biosamples (144 persons). According to the film badge data, the monthly over-exposures (more than 4 mGy) totalled 427. In 13 cases the monthly exposure exceeded 30 mGy, 8 persons received annual doses in the range of 50 to 120 mGy, and the highest annual dose was above 250 mGy. Also, annual collective and annual per caput doses have been given for the exposed population as a whole and some subgroups. Based on model considerations, the internal radiation exposure situation resulting from unintentional intakes of radionuclides has been assessed in terms of committed dose equivalents to members of two selected groups of radiation workers: (a) persons with more-than-average internal contamination levels; (b) persons subjected to frequent individual monitoring. Except for some organ doses, the individual internal radiation exposure was well below one-tenth the maximum permissible dose. (author)

  14. Introduction of Counter-Proliferation Capabilities in Development States

    International Nuclear Information System (INIS)

    Caulfield, P.; Edwards, T.; Witkin, A.; Elgebaly, A.

    2010-01-01

    In recent history we have seen a number of States develop their indigenous industrial skills to a point suitable for the manufacture of nuclear components. Private individuals unbeknown to the State have then utilized this capability to supply directly into proliferation networks - potentially reducing international confidence in such a State. To combat this possibility, a developing State must recognize the challenges that are raised by its emerging skills and take action to introduce measures that not only help the State identify proliferation activities but also ensure the national security of the State. One of those measures might be to develop a capability within the State to recognize and counter the activities of would-be-proliferators. In many States this capability is managed and applied through a dedicated counter-proliferation unit that has strong links with border controls and customs organizations. A counter-proliferation unit, once established could show dramatic returns for a modest investment. The activities of such a Unit could save the State political embarrassment by hindering and narrowing the chances of unintentional proliferation activities. The Unit should not be introduced as part of a Safeguards agreement or as part of a non proliferation treaty. It should rather be established as an act by the State to protect and control its emerging technologies from being involved, willingly or unwittingly, in proliferation activities. This is a sovereign act of the State - solely for its benefit and should not be imposed by any external power. Today's would-be-proliferators around the world cooperate and act together; similarly emerging counter-proliferation units should act and work together in order to be a step ahead of the proliferators. Improved world-wide cooperation should increase the detection rate of proliferation incidents which will in turn curtail the spread of nuclear weapons - for the benefit of all. (author)

  15. Cerenkov counters at the Omega Facility

    CERN Multimedia

    1975-01-01

    P. Petroff on the left. Here one sees both the gas Cerenkov counters sitting in front of the magnet to select forward emitted particles. The smaller one, working at high pressure, sits nearest to the Omega magnet (see photo 7505073X), the other (see photo 7505071X) works at atmospheric pressure.

  16. Synchrotron radiation and multichannel detectors in structural analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mokulskii, M

    1979-10-01

    A survey is presented of the development of multichannel synchrotron X radiation detectors for the structural analysis of crystals. Tests are currently under way of a 4-thousand-channel plane detector of soft X radiation. The detector consists of a multiwire proportional counter using argon and CO/sub 2/ as the working gases. The detector is coupled to a computer processing information and displaying the respective X-ray diffraction images on the monitor. The described equipment allows imaging, eg., the cross section of the elementary cell of a DNA crystal. A 16-thousand-channel detector exists in the present time and the building is envisaged of a detector with 65 thousand channels.

  17. Synchrotron radiation and multichannel detectors in structural analysis

    International Nuclear Information System (INIS)

    Mokulskij, M.

    1979-01-01

    A survey is presented of the development of multichannel synchrotron X radiation detectors for the structural analysis of crystals. Tests are currently under way of a 4-thousand-channel plane detector of soft X radiation. The detector consists of a multiwire proportional counter using argon and CO 2 as the working gases. The detector is coupled to a computer processing information and displaying the respective X-ray diffraction images on the monitor. The described equipment allows imaging, eg., the cross section of the elementary cell of a DNA crystal. A 16-thousand-channel detector exists in the present time and the building is envisaged of a detector with 65 thousand channels. (J.B.)

  18. High resolution time-of-flight measurements in small and large scintillation counters

    International Nuclear Information System (INIS)

    D'Agostini, G.; Marini, G.; Martellotti, G.; Massa, F.; Rambaldi, A.; Sciubba, A.

    1981-01-01

    In a test run, the experimental time-of-flight resolution was measured for several different scintillation counters of small (10 x 5 cm 2 ) and large (100 x 15 cm 2 and 75 x 25 cm 2 ) area. The design characteristics were decided on the basis of theoretical Monte Carlo calculations. We report results using twisted, fish-tail, and rectangular light- guides and different types of scintillator (NE 114 and PILOT U). Time resolution up to approx. equal to 130-150 ps fwhm for the small counters and up to approx. equal to 280-300 ps fwhm for the large counters were obtained. The spatial resolution from time measurements in the large counters is also reported. The results of Monte Carlo calculations on the type of scintillator, the shape and dimensions of the light-guides, and the nature of the external wrapping surfaces - to be used in order to optimize the time resolution - are also summarized. (orig.)

  19. Winning the Battle but Losing the War? Narrative and Counter-Narratives Strategy

    Directory of Open Access Journals (Sweden)

    Christian Leuprecht

    2010-11-01

    Full Text Available Since 9/11, intelligence and security services have become particularly concerned about radical ideologies and have looked for ways on how to counter them. One of the strategies has been to develop a counter-narrative. Some authors, including those of this article, are concerned that, in the marketplace of ideas, the West is losing market-share.[1] Communication failures with the Muslim world were cited in a report by a U.S. Department of Defence Advisory Committee as early as 2004.[2] The puzzle this article explores is why, having recognized the problem early on, the data suggest that further ground has since been lost. We posit the problem as having to shift the discourse from one focusing on a single counter-narrative to one of tailoring communications to target specific audiences. The article traces methodological and empirical shortcomings that are at the root of the problem and builds on these findings to develop a model to strategize about counter-narratives.

  20. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    OpenAIRE

    Leicht, Carola; Goclowska, Malgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadersh...

  1. First Townsend coefficient of organic vapour in avalanche counters

    International Nuclear Information System (INIS)

    Sernicki, J.

    1990-01-01

    A new concept is presented in the paper for implementing the proven method of determining the first Townsend coefficient (α) of gases using an avalanche counter. The A and B gas constants, interrelated by the expression α/p=A exp[-B/(K/p)], are analyzed. Parallel-plate avalanche counters (PPAC) with an electrode spacing d from 0.1 to 0.4 cm have been employed for the investigation, arranged to register low-energy alpha particles at n-heptane vapour pressures of p≥5 Torr. An in-depth discussion is given, covering the veracity and the behaviour vs K/p, of the n-heptane A and B constants determined at reduced electric-field intensity values ranging from 173.5 to 940 V/cm Torr; the constants have been found to depend upon d. The results of the investigation are compared to available data of the α coefficient of organic vapours used in avalanche counters. The PPAC method of determining α reveals some imperfections at very low values of the pd product. (orig.)

  2. Nitrogen large area proportional counter with gas regeneration

    International Nuclear Information System (INIS)

    Leidner, L.; Sadri, E.

    1984-10-01

    A nitrogen large area proportional chamber with gas regeneration is introduced to measure alpha and beta/gamma activites. In contrast to the flow counters used till now the new detector is independent of an external gas supply. The gas amplification factor of nitrogen keeps constant up to an impurity of 2% of O 2 . Oxygen diffusing through unavoidable leakages into the counting gas is removed by an activated catalyzer using low temperature copper oxidation. Humidty is adsorbed by a molecular sieve. The closed counter consists of three components: the actual detector, a gas purification cartridge and a gas circulating pump. Finally, the report describes long run experiments being carried out with prototypes. (orig./HP) [de

  3. Proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons

    Energy Technology Data Exchange (ETDEWEB)

    Marzec, J.; Pawlowski, Z. (Politechnika Warszawska (Poland). Inst. Radioelektroniki)

    1982-09-15

    The work describes the construction of a proportional counter with a uniform electric field in the zone of avalanche multiplication of electrons. It has been shown that in this counter filled with Penning's mixtures Ne+Ar+CO/sub 2/, Ne+CH/sub 4/ and Ar+C/sub 2/H/sub 2/, much higher resolutions are obtained than in typical cylindrical counters. In the counter described filled with a mixture of Ne+1%CH/sub 4/, a resolution of fwhm=10.5% has been obtained for E=5.9 keV.

  4. Effectiveness of Counter-Trafficking Response in Albania

    Directory of Open Access Journals (Sweden)

    Meçe Merita H.

    2016-07-01

    Full Text Available Human trafficking is a new phenomenon of Albanian post-socialist society which significantly increased during the difficult years of its transformation from centralized state-led economy to market economy. Both economic and political instability contributed to its size, nature and multiple dynamics. Drawing on a rights-based approach to human trafficking, this paper examines the effectiveness of the counter-trafficking response of the Albanian government with a special emphasis on prevention, protection and prosecution. Using secondary data and reviewing various country strategic documents, it highlights a range of weaknesses and challenges which have hindered its effectiveness over years. It concludes that successful and effective counter-trafficking response requires well rounded and coordinated gender sensitive, victim-centred, holistic and human rights-based efforts. Combined with adequate law enforcement, they will sustainably tackle the full spectrum of this problem.

  5. People's practices : exploring contestation, counter-development, and rural livelihoods : ...cases from Muktinagar, Bangladesh

    NARCIS (Netherlands)

    Huq, H.

    2000-01-01

    People's Practices: Exploring contestation, Counter - development, and rural livelihoods

    The central problems explored in the thesis concern the vulnerability of disadvantaged local people, especially women, and their agency; development discourses and counter-development

  6. Counter-intuitive moral judgement following traumatic brain injury.

    Science.gov (United States)

    Rowley, Dane A; Rogish, Miles; Alexander, Timothy; Riggs, Kevin J

    2017-02-07

    Several neurological patient populations, including traumatic brain injury (TBI), appear to produce an abnormally 'utilitarian' pattern of judgements to moral dilemmas; they tend to make judgements that maximize the welfare of the majority, rather than deontological judgements based on the following of moral rules (e.g., do not harm others). However, this patient research has always used extreme dilemmas with highly valued moral rules (e.g., do not kill). Data from healthy participants, however, suggest that when a wider range of dilemmas are employed, involving less valued moral rules (e.g., do not lie), moral judgements demonstrate sensitivity to the psychological intuitiveness of the judgements, rather than their deontological or utilitarian content (Kahane et al., Social Cognitive and Affective Neuroscience, 7, 2011, 393). We sought the moral judgements of 30 TBI participants and 30 controls on moral dilemmas where content (utilitarian/deontological) and intuition (intuitive/counter-intuitive) were measured concurrently. Overall TBI participants made utilitarian judgements in equal proportions to controls; disproportionately favouring utilitarian judgements only when they were counter-intuitive, and deontological judgements only when they were counter-intuitive. These results speak against the view that TBI causes a specific utilitarian bias, suggesting instead that moral intuition is broadly disrupted following TBI. © 2017 The British Psychological Society.

  7. Value for Money? Problems of Impact Assessment of Counter-radicalization Policies on End Target Groups

    DEFF Research Database (Denmark)

    Lindekilde, Lasse

    2012-01-01

    There is a lack of consensus in the academic literature and among policy makers and practitioners on the definition of violent radicalisation, and current counter-radicalisation policy responses and procedures are informed by a weak and, at times, confused understanding of the motivational...... and structural factors underpinning such a process. The result is a variety of interventions across the EU, signalling a lack of consensus on the purposes of counter-radicalisation. In addition, indicators of success of counter-radicalisation policies are often unclear or unspecified. One consequence...... of this is that assessments of the effectiveness of counter-radicalisation measures and policy responses are either lacking or often methodologically questionable, impairing our understanding of the impacts of counter-radicalisation interventions on targeted communities. The article investigates problems of assessing...

  8. The significance of interconnector counter-trading in a security constrained electricity market

    International Nuclear Information System (INIS)

    Higgins, P.; Li, K.; Devlin, J.; Foley, A.M.

    2015-01-01

    Throughout the European Union there is an increasing amount of wind generation being dispatched-down due to the binding of power system operating constraints from high levels of wind generation. This paper examines the impact a system non-synchronous penetration limit has on the dispatch-down of wind and quantifies the significance of interconnector counter-trading to the priority dispatching of wind power. A fully coupled economic dispatch and security constrained unit commitment model of the Single Electricity Market of the Republic of Ireland and Northern Ireland and the British Electricity Trading and Transmission Arrangement was used in this study. The key finding was interconnector counter-trading reduces the impact the system non-synchronous penetration limit has on the dispatch-down of wind. The capability to counter-trade on the interconnectors and an increase in system non-synchronous penetration limit from 50% to 55% reduces the dispatch-down of wind by 311 GW h and decreases total electricity payments to the consumer by €1.72/MW h. In terms of the European Union electricity market integration, the results show the importance of developing individual electricity markets that allow system operators to counter-trade on interconnectors to ensure the priority dispatch of the increasing levels of wind generation. - Highlights: • Interconnector counter-trading reduces the system marginal price in the SEM. • Dispatch-down of wind power is reduced due to interconnector counter-trading. • A 5% increase in the SNSP limit can reduce wind power dispatched-down by 50%. • An increase in the SNSP limit and installed wind capacity reduces the SMP.

  9. MCNP modelling of the wall effects observed in tissue-equivalent proportional counters.

    Science.gov (United States)

    Hoff, J L; Townsend, L W

    2002-01-01

    Tissue-equivalent proportional counters (TEPCs) utilise tissue-equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Density differences between the two materials cause distortions, or wall effects, in measurements, with the most dominant effect caused by delta rays. This study uses a Monte Carlo transport code, MCNP, to simulate the transport of secondary electrons within a TEPC. The Rudd model, a singly differential cross section with no dependence on electron direction, is used to describe the energy spectrum obtained by the impact of two iron beams on water. Based on the models used in this study, a wall-less TEPC had a higher lineal energy (keV.micron-1) as a function of impact parameter than a solid-wall TEPC for the iron beams under consideration. An important conclusion of this study is that MCNP has the ability to model the wall effects observed in TEPCs.

  10. Precipitation and Hydrology Experiment Counter-Flow Spectrometer and Impactor Field Campaign Report

    Energy Technology Data Exchange (ETDEWEB)

    Poellot, Michael [University of North Dakota

    2016-03-01

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Aerial Facility (ARM AAF) counter-flow spectrometer and impactor (CSI) probe was flown on the University of North Dakota Cessna Citation research aircraft during the Integrated Precipitation and Hydrology Experiment (IPHEX). The field campaign took place during May and June of 2014 over North Carolina and its coastal waters as part of a National Aeronautics and Space Administration (NASA) Global Precipitation Measurement validation campaign. The CSI was added to the Citation instrument suite to support the involvement of Jay Mace through the NASA Advanced Composition Explorer (ACE) satellite program and flights of the NASA ER-2 aircraft, which is a civilian version of the Air Force’s U2-S reconnaissance platform. The ACE program funded extra ER-2 flights to focus on clouds that are weakly precipitating, which are also of interest to the Atmospheric System Research program sponsored by DOE.

  11. On the use of single large-area photodiodes in scintillation counters

    International Nuclear Information System (INIS)

    Morrell, C.

    1989-12-01

    The compilation of this review was originally intended to assess the possibility of using photodiode-based scintillation counters in fluorescence EXAFS (or FLEXAFS) systems as a low-cost alternative to photomultiplier-based counters. The X-ray energies encountered in FLEXAFS experiments range from a few keV to a few tens of keV, and detectors are required to have some energy resolution and/or high count-rate capability in order to optimize the quality of data collected. The results presented in the reviewed literature imply strongly that photodiodes do not compete successfully with photomultipliers in scintillation counting systems for X-ray energies below the order of 100keV, at least at the present stage of photodiode technology. Nevertheless it is likely that there are other applications requiring X-ray detectors for which a photodiode-based scintillation counter may be perfectly adequate, and it is therefore felt that such a review is still useful. In addition, large-area single photodiodes have much to offer as X-ray detectors in their own right, and several of the considerations regarding their use in scintillation counters are highly relevant to this application. (author)

  12. Geiger counters of gamma rays with a bismuth cathode; Compteurs de geiger a rayons gamma a cathode de bismuth

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, R; Legrand, J P [Commissariat a l' Energie Atomique, Saclay(France). Centre d' Etudes Nucleaires

    1953-07-01

    Geiger Muller counters present a lake of efficiency of some per cent, for the {gamma} radiations. In the region 0,3 - 1 MeV, a substantial growth of their output can be obtained by a special construction of their cathode. In accordance with previous works, we constructed some counter of formed cathode by a pleated copper wire fencing covered of Bi by electrolysis. The successive modifications brought to a cylindrical conventional cathode in sheet metal of copper, that succeeds to this type of cathode, drive to an improvement of the output. (M.B.) [French] Les compteurs de Geiger Muller presentent une efficacite assez faible de l'ordre de quelques pour cent, pour les rayonnements {gamma}. Dans la region 0,3 - 1 MeV, un accroissement substantiel de leur rendement peut etre obtenu par une construction speciale de leur cathode. Conformement a des travaux anterieurs, nous avons construit des compteurs a cathode formee par un grillage de cuivre plisse recouvert de Bi par electrolyse. Les modifications successives apportees a une cathode conventionnelle cylindrique en tole de cuivre, qui aboutissent a ce type de cathode, conduisent a une amelioration du rendement. (M.B.)

  13. Transference, counter-transference and repetition: some implications for nursing practice.

    Science.gov (United States)

    Jones, Alun C

    2005-11-01

    This discussion paper offers an introductory text for nurses and explores the psychoanalytic ideas of transference, counter-transference and repetition compulsion. Disguised case vignettes provide illustrations of the ideas as they might apply to nursing, including professional practice and occupational choice. The literature suggests that transference can be a source of creativity as well as destructiveness and influence important communications with oneself and others including the choice of nursing and other health professions as an occupation. Recognizing possibilities of transference, counter-transference along with repetitive patterns of behaviours, can help nurses of all specialities to address situations constructively by responding thoughtfully and appropriately. This discussion concludes with the suggestions that we know little about the motivational factors underlying nursing as an occupational preference; moreover, nursing does not have a culture of personal therapy. As such nurses are denied opportunities to understand the possible reasons underlying their occupational choice or gain experiential knowledge of interpersonal dynamics occurring between patients and colleagues. Transference and counter-transference are thought to have some bearing on all relationships. Forming a natural part of the way human beings relate to each other, transference and counter-transference can bring about sincere human interest, caring and concern. However, there is also potential for disagreements. Recognizing the possible origins of relational difficulties can offer opportunities for professional development to nurses along with the benefits for health service users.

  14. An integrated photosensor readout for gas proportional scintillation counters

    International Nuclear Information System (INIS)

    Lopes, J.A.M.; Santos, J.M.F. dos; Conde, C.A.N.

    1996-01-01

    A xenon gas proportional scintillation counter has been instrumented with a novel photosensor that replaces the photomultiplier tube normally used to detect the VUV secondary scintillation light. In this implementation, the collection grid of a planar gas proportional scintillation counter also functions as a multiwire proportional chamber to amplify and detect the photoelectrons emitted by a reflective CsI photocathode in direct contact with the xenon gas. This integrated concept combines greater simplicity, compactness, and ruggedness (no optical window is used) with low power consumption. An energy resolution of 12% was obtained for 59.6 keV x-rays

  15. Energy resolution limitations in a gas scintillation proportional counter

    International Nuclear Information System (INIS)

    Simons, D.G.; de Korte, P.A.J.; Peacock, A.; Bleeker, J.A.M.

    1985-01-01

    An investigation is made of the factors limiting the energy resolution of a gas scintillation proportional counter (GSPC). Several of these limitations originate in the drift region of such a counter and data is presented, giving a quantitative description of those effects. Data is also presented of a GSPC without a drift region, that therefore largely circumvents most of those degrading factors. The results obtained so far indicate that in that detector the limitation to the resolution is most probably due to cleanliness of the gas. Further research is underway in order to assess quantitatively the limiting factors in such a driftless GSPC

  16. The Use of Force in Modern Counter-Terrorism: International Legal and Political Aspects

    Directory of Open Access Journals (Sweden)

    Elizaveta Sergeevna Gromoglasova

    2016-12-01

    Full Text Available The paper reviews the recent practice of the use of military force in extraterritorial counter-terrorist operations. It argues that nowadays we're witnessing a new stage in the 'war on terror' that's still going on. Although the most of the modern counter-terrorist operations like, for example, the US-led coalition against ISIL in Iraq are being conducted at the request of the affected government, the major risks of expanding and misuse of the right on individual or collective self-defense enshrined in the UN Charter are still present. This can be illustrated by reference to the US air strikes on ISIL in Syria that have been undertaken without consent of Syrian government. But the challenges emerging from 'failed states' and rise of new more radical and militant terrorist movements (ISIL, Ash-Shabaab, Boko Haram and others change the perceptions of legality of extraterritorial counter-terrorist force. The approach which reaffirms responsibility of the state for suppressing terrorist groups operating from within its territory seems to become more and more acceptable. Accordingly, if the state can't suppress terrorist activity it should accept the counter-terrorist intervention on its territory. Nevertheless, jus in bello norms (first of all international humanitarian law remain stringent legal framework for actual use of counter-terrorist military force. The paper concludes that overall political legitimacy of the modern military counter-terrorist operations should be accessed in terms of their humanitarian impact and consequences.

  17. Mechanism of supporting sub-communicator collectives with O(64) counters as opposed to one counter for each sub-communicator

    Science.gov (United States)

    Kumar, Sameer; Mamidala, Amith R.; Ratterman, Joseph D.; Blocksome, Michael; Miller, Douglas

    2013-09-03

    A system and method for enhancing barrier collective synchronization on a computer system comprises a computer system including a data storage device. The computer system includes a program stored in the data storage device and steps of the program being executed by a processor. The system includes providing a plurality of communicators for storing state information for a bather algorithm. Each communicator designates a master core in a multi-processor environment of the computer system. The system allocates or designates one counter for each of a plurality of threads. The system configures a table with a number of entries equal to the maximum number of threads. The system sets a table entry with an ID associated with a communicator when a process thread initiates a collective. The system determines an allocated or designated counter by searching entries in the table.

  18. Mechanism of supporting sub-communicator collectives with o(64) counters as opposed to one counter for each sub-communicator

    Science.gov (United States)

    Blocksome, Michael; Kumar, Sameer; Mamidala, Amith R.; Miller, Douglas; Ratterman, Joseph D.

    2016-01-26

    A system and method for enhancing barrier collective synchronization on a computer system comprises a computer system including a data storage device. The computer system includes a program stored in the data storage device and steps of the program being executed by a processor. The system includes providing a plurality of communicators for storing state information for a barrier algorithm. Each communicator designates a master core in a multi-processor environment of the computer system. The system allocates or designates one counter for each of a plurality of threads. The system configures a table with a number of entries equal to the maximum number of threads. The system sets a table entry with an ID associated with a communicator when a process thread initiates a collective. The system determines an allocated or designated counter by searching entries in the table.

  19. Counter Trafficking System Development "Analysis Training Program"

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Dennis C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-12-01

    This document will detail the training curriculum for the Counter-Trafficking System Development (CTSD) Analysis Modules and Lesson Plans are derived from the United States Military, Department of Energy doctrine and Lawrence Livermore National Laboratory (LLNL), Global Security (GS) S Program.

  20. Expertise in unexpected places: Children's acceptance of information from gender counter-stereotypical experts.

    Science.gov (United States)

    Boseovski, Janet J; Hughes, Chelsea; Miller, Stephanie E

    2016-01-01

    The current study examined children's willingness to accept novel information from expert informants with nontraditional gender role interests. Four- to 8-year-olds heard conflicting information about traditionally feminine or masculine domains from a gender counter-stereotypical expert (e.g., a boy with expertise in ballet) and a layperson of the other gender (e.g., a girl with little knowledge about ballet). Participants were asked which informant was correct, who they would prefer to learn from in the future, and to rate their liking of each informant. Overall, participants selected the gender counter-stereotypical expert as correct. Four- to 5-year-olds reported a preference to learn from same-gender participants in the future irrespective of expertise, whereas 6- to 8-year-olds reported wanting to learn from counter-stereotypical experts. Boys showed relatively greater acceptance of information from a male counter-stereotypical expert than from a female counter-stereotypical expert. Although participants reported greater liking of same-gender informants, liking evaluations were largely positive irrespective of gender norm deviations. Implications for children's acceptance of gender nonconforming activities are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.