WorldWideScience

Sample records for count rate saturation

  1. Counting losses due to saturation effects of scintillation counters at high count rates

    CERN Document Server

    Hashimoto, K

    1999-01-01

    The counting statistics of a scintillation counter, with a preamplifier saturated by an overloading input, are investigated. First, the formulae for the variance and the mean number of counts, accumulated within a given gating time, are derived by considering counting-loss effects originating from the saturation and a finite resolving time of the electronic circuit. Numerical examples based on the formulae indicate that the saturation makes a positive contribution to the variance-to-mean ratio and that the contribution increases with count rate. Next the ratios are measured under high count rates when the preamplifier saturation can be observed. By fitting the present formula to the measured data, the counting-loss parameters can be evaluated. Corrections based on the parameters are made for various count rates measured in a nuclear reactor. As a result of the corrections, the linearity between count rate and reactor power can be restored.

  2. High Count Rate Single Photon Counting Detector Array Project

    Data.gov (United States)

    National Aeronautics and Space Administration — An optical communications receiver requires efficient and high-rate photon-counting capability so that the information from every photon, received at the aperture,...

  3. Count rate performance of a silicon-strip detector for photon-counting spectral CT

    Science.gov (United States)

    Liu, X.; Grönberg, F.; Sjölin, M.; Karlsson, S.; Danielsson, M.

    2016-08-01

    A silicon-strip detector is developed for spectral computed tomography. The detector operates in photon-counting mode and allows pulse-height discrimination with 8 adjustable energy bins. In this work, we evaluate the count-rate performance of the detector in a clinical CT environment. The output counts of the detector are measured for x-ray tube currents up to 500 mA at 120 kV tube voltage, which produces a maximum photon flux of 485 Mphotons/s/mm2 for the unattenuated beam. The corresponding maximum count-rate loss of the detector is around 30% and there are no saturation effects. A near linear relationship between the input and output count rates can be observed up to 90 Mcps/mm2, at which point only 3% of the input counts are lost. This means that the loss in the diagnostically relevant count-rate region is negligible. A semi-nonparalyzable dead-time model is used to describe the count-rate performance of the detector, which shows a good agreement with the measured data. The nonparalyzable dead time τn for 150 evaluated detector elements is estimated to be 20.2±5.2 ns.

  4. High Count Rate Electron Probe Microanalysis

    Science.gov (United States)

    Geller, Joseph D.; Herrington, Charles

    2002-01-01

    Reducing the measurement uncertainty of quantitative analyses made using electron probe microanalyzers (EPMA) requires a careful study of the individual uncertainties from each definable step of the measurement. Those steps include measuring the incident electron beam current and voltage, knowing the angle between the electron beam and the sample (takeoff angle), collecting the emitted x rays from the sample, comparing the emitted x-ray flux to known standards (to determine the k-ratio) and transformation of the k-ratio to concentration using algorithms which includes, as a minimum, the atomic number, absorption, and fluorescence corrections. This paper discusses the collection and counting of the emitted x rays, which are diffracted into the gas flow or sealed proportional x-ray detectors. The representation of the uncertainty in the number of collected x rays collected reduces as the number of counts increase. The uncertainty of the collected signal is fully described by Poisson statistics. Increasing the number of x rays collected involves either counting longer or at a higher counting rate. Counting longer means the analysis time increases and may become excessive to get to the desired uncertainty. Instrument drift also becomes an issue. Counting at higher rates has its limitations, which are a function of the detector physics and the detecting electronics. Since the beginning of EPMA analysis, analog electronics have been used to amplify and discriminate the x-ray induced ionizations within the proportional counter. This paper will discuss the use of digital electronics for this purpose. These electronics are similar to that used for energy dispersive analysis of x rays with either Si(Li) or Ge(Li) detectors except that the shaping time constants are much smaller. PMID:27446749

  5. Estimation of Saturation Flow Rates at Signalized Intersections

    Directory of Open Access Journals (Sweden)

    Chang-qiao Shao

    2012-01-01

    Full Text Available The saturation flow rate is a fundamental parameter to measure the intersection capacity and time the traffic signals. However, it is revealed that traditional methods which are mainly developed using the average value of observed queue discharge headways to estimate the saturation headway might lead to underestimate saturation flow rate. The goal of this paper is to study the stochastic nature of queue discharge headways and to develop a more accurate estimate method for saturation headway and saturation flow rate. Based on the surveyed data, the characteristics of queue discharge headways and the estimation method of saturated flow rate are studied. It is found that the average value of queue discharge headways is greater than the median value and that the skewness of the headways is positive. Normal distribution tests were conducted before and after a log transformation of the headways. The goodness-of-fit test showed that for some surveyed sites, the queue discharge headways can be fitted by the normal distribution and for other surveyed sites, the headways can be fitted by lognormal distribution. According to the queue discharge headway characteristics, the median value of queue discharge headways is suggested to estimate the saturation headway and a new method of estimation saturation flow rates is developed.

  6. High counting rate resistive-plate chamber

    Science.gov (United States)

    Peskov, V.; Anderson, D. F.; Kwan, S.

    1993-05-01

    Parallel-plate avalanche chambers (PPAC) are widely used in physics experiments because they are fast (less than 1 ns) and have very simple construction: just two parallel metallic plates or mesh electrodes. Depending on the applied voltage they may work either in spark mode or avalanche mode. The advantage of the spark mode of operation is a large signal amplitude from the chamber, the disadvantage is that there is a large dead time (msec) for the entire chamber after an event. The main advantage of the avalanche mode is high rate capability 10(exp 5) counts/mm(sup 2). A resistive-plate chamber (RPC) is similar to the PPAC in construction except that one or both of the electrodes are made from high resistivity (greater than 10(exp 10) Omega(cm) materials. In practice RPC's are usually used in the spark mode. Resistive electrodes are charged by sparks, locally reducing the actual electric field in the gap. The size of the charged surface is about 10 mm(sup 2), leaving the rest of the detector unaffected. Therefore, the rate capability of such detectors in the spark mode is considerably higher than conventional spark counters. Among the different glasses tested the best results were obtained with electron type conductive glasses, which obey Ohm's law. Most of the work with such glasses was done with high pressure parallel-plate chambers (10 atm) for time-of-flight measurements. Resistive glasses have been expensive and produced only in small quantities. Now resistive glasses are commercially available, although they are still expensive in small scale production. From the positive experience of different groups working with the resistive glasses, it was decided to review the old idea to use this glass for the RPC. This work has investigated the possibility of using the RPC at 1 atm and in the avalanche mode. This has several advantages: simplicity of construction, high rate capability, low voltage operation, and the ability to work with non-flammable gases.

  7. Relationship between salivary flow rates and Candida albicans counts.

    Science.gov (United States)

    Navazesh, M; Wood, G J; Brightman, V J

    1995-09-01

    Seventy-one persons (48 women, 23 men; mean age, 51.76 years) were evaluated for salivary flow rates and Candida albicans counts. Each person was seen on three different occasions. Samples of unstimulated whole, chewing-stimulated whole, acid-stimulated parotid, and candy-stimulated parotid saliva were collected under standardized conditions. An oral rinse was also obtained and evaluated for Candida albicans counts. Unstimulated and chewing-stimulated whole flow rates were negatively and significantly (p or = 500 count. Differences in stimulated parotid flow rates were not significant among different levels of Candida counts. The results of this study reveal that whole saliva is a better predictor than parotid saliva in identification of persons with high Candida albicans counts.

  8. Preset time count rate meter using adaptive digital signal processing

    Directory of Open Access Journals (Sweden)

    Žigić Aleksandar D.

    2005-01-01

    Full Text Available Two presented methods were developed to improve classical preset time count rate meters by using adapt able signal processing tools. An optimized detection algorithm that senses the change of mean count rate was implemented in both methods. Three low-pass filters of various structures with adaptable parameters to implement the control of the mean count rate error by suppressing the fluctuations in a controllable way, were considered and one of them implemented in both methods. An adaptation algorithm for preset time interval calculation executed after the low-pass filter was devised and implemented in the first method. This adaptation algorithm makes it possible to obtain shorter preset time intervals for higher stationary mean count rate. The adaptation algorithm for preset time interval calculation executed before the low-pass filter was devised and implemented in the second method. That adaptation algorithm enables sensing of a rapid change of the mean count rate before fluctuations suppression is carried out. Some parameters were fixed to their optimum values after appropriate optimization procedure. Low-pass filters have variable number of stationary coefficients depending on the specified error and the mean count rate. They implement control of the mean count rate error by suppressing fluctuations in a controllable way. The simulated and realized methods, using the developed algorithms, guarantee that the response time shall not exceed 2 s for the mean count rate higher than 2 s-1 and that controllable mean count rate error shall be within the range of ±4% to ±10%.

  9. Tracking Controller for Intrinsic Output Saturated Systems in Presence of Amplitude and Rate Input Saturations

    DEFF Research Database (Denmark)

    Chater, E.; Giri, F.; Guerrero, Josep M.;

    2014-01-01

    We consider the problem of controlling plants that are subject to multiple saturation constraints. Especially, we are interested in linear systems whose input is subject to amplitude and rate constraints of saturation type. Furthermore, the considered systems output is also subject to an intrinsic......-loop control system is analyzed using input-output stability tools. Thus, conditions guaranteeing l2-tracking performances are formally defined. Interestingly, the proposed controller is shown to ensure perfect output-reference tracking in presence of varying with l2-vanishing rate inputs. On the other hand......, in the case of arbitrary inputs, the proposed controller guarantees that the less changing the inputs are the better the output-reference tracking....

  10. Characterization of the count rate performance of modern gamma cameras

    Science.gov (United States)

    Silosky, M.; Johnson, V.; Beasley, C.; Cheenu Kappadath, S.

    2013-01-01

    Purpose: Evaluation of count rate performance (CRP) is an integral component of gamma camera quality assurance and system deadtime (τ) may be utilized for image correction in quantitative studies. This work characterizes the CRP of three modern gamma cameras and estimates τ using two established methods (decay and dual source) under a variety of experimental conditions. Methods: For the decay method, uncollimated detectors were exposed to a Tc-99m source of relatively high activity and count rates were sampled regularly over 48 h. Input count rate at each time point was based on the lowest observed count rate data point. The input count rate was plotted against the observed count rate and fit via least-squares to the paralyzable detector model (PDM) to estimate τ (rates method). A novel expression for observed counts as a function of measurement time interval was derived, taking into account the PDM and the presence of background but making no assumption regarding input count rate. The observed counts were fit via least-squares to this novel expression to estimate τ (counts method). Correlation and Bland-Altman analyses were performed to assess agreement in estimates of τ between the rates and counts methods. The dependence of τ on energy window definition and incident energy spectrum were characterized. The dual source method was also used to estimate τ and its agreement with estimates from the decay method under identical conditions was also investigated. The dependences of τ on the total activity and the ratio of source activities were characterized. Results: The observed CRP curves for each gamma camera agreed with the PDM at low count rates but deviated substantially from it at high count rates. The estimates of τ determined from the paralyzable portion of the CPR curve using the rates method and the counts method were found to be highly correlated (r = 0.999) but with a small (∼6%) difference. No statistically significant difference was observed

  11. Flight Control System Design with Rate Saturating Actuators

    Science.gov (United States)

    Hess, R. A.; Snell, S. A.

    1997-01-01

    Actuator rate saturation is an important factor adversely affecting the stability and performance of aircraft flight control systems. It has been identified as a catalyst in pilot-induced oscillations, some of which have been catastrophic. A simple design technique is described that utilizes software rate limiters to improve the performance of control systems operating in the presence of actuator rate saturation. As described, the technique requires control effectors to be ganged such that any effector is driven by only a single compensated error signal. Using an analysis of the steady-state behavior of the system, requirements are placed upon the type of the loop transmissions and compensators in the proposed technique. Application of the technique to the design of a multi-input/multi-output, lateral-directional control system for a simple model of a high-performance fighter is demonstrated as are the stability and performance improvements that can accrue with the technique.

  12. Robust, Decoupled, Flight Control Design with Rate Saturating Actuators

    Science.gov (United States)

    Snell, S. A.; Hess, R. A.

    1997-01-01

    Techniques for the design of control systems for manually controlled, high-performance aircraft must provide the following: (1) multi-input, multi-output (MIMO) solutions, (2) acceptable handling qualities including no tendencies for pilot-induced oscillations, (3) a tractable approach for compensator design, (4) performance and stability robustness in the presence of significant plant uncertainty, and (5) performance and stability robustness in the presence actuator saturation (particularly rate saturation). A design technique built upon Quantitative Feedback Theory is offered as a candidate methodology which can provide flight control systems meeting these requirements, and do so over a considerable part of the flight envelope. An example utilizing a simplified model of a supermaneuverable fighter aircraft demonstrates the proposed design methodology.

  13. Reducing the Teen Death Rate. KIDS COUNT Indicator Brief

    Science.gov (United States)

    Shore, Rima; Shore, Barbara

    2009-01-01

    Life continues to hold considerable risk for adolescents in the United States. In 2006, the teen death rate stood at 64 deaths per 100,000 teens (13,739 teens) (KIDS COUNT Data Center, 2009). Although it has declined by 4 percent since 2000, the rate of teen death in this country remains substantially higher than in many peer nations, based…

  14. Determination of saturation, heart rate, and respiratory rate at forearm using a Nellcor™ forehead SpO2-saturation sensor.

    Science.gov (United States)

    Harju, Jarkko; Vehkaoja, Antti; Lindroos, Ville; Kumpulainen, Pekka; Liuhanen, Sasu; Yli-Hankala, Arvi; Oksala, Niku

    2016-10-17

    Alterations in arterial blood oxygen saturation, heart rate (HR), and respiratory rate (RR) are strongly associated with intra-hospital cardiac arrests and resuscitations. A wireless, easy-to-use, and comfortable method for monitoring these important clinical signs would be highly useful. We investigated whether the Nellcor™ OxiMask MAX-FAST forehead sensor could provide data for vital sign measurements when located at the distal forearm instead of its intended location at the forehead to provide improved comfortability and easy placement. In a prospective setting, we recruited 30 patients undergoing surgery requiring postoperative care. At the postoperative care unit, patients were monitored for two hours using a standard patient monitor and with a study device equipped with a Nellcor™ Forehead SpO2 sensor. The readings were electronically recorded and compared in post hoc analysis using Bland-Altman plots, Spearman's correlation, and root-mean-square error (RMSE). Bland-Altman plot showed that saturation (SpO2) differed by a mean of -0.2 % points (SD, 4.6), with a patient-weighted Spearman's correlation (r) of 0.142, and an RMSE of 4.2 points. For HR measurements, the mean difference was 0.6 bpm (SD, 2.5), r = 0.997, and RMSE = 1.8. For RR, the mean difference was -0.5 1/min (4.1), r = 0.586, and RMSE = 4.0. The SpO2 readings showed a low mean difference, but also a low correlation and high RMSE, indicating that the Nellcor™ saturation sensor cannot reliably assess oxygen saturation at the forearm when compared to finger PPG measurements.

  15. Practical remarks on the heart rate and saturation measurement methodology

    Science.gov (United States)

    Kowal, M.; Kubal, S.; Piotrowski, P.; Staniec, K.

    2017-05-01

    A surface reflection-based method for measuring heart rate and saturation has been introduced as one having a significant advantage over legacy methods in that it lends itself for use in special applications such as those where a person’s mobility is of prime importance (e.g. during a miner’s work) and excluding the use of traditional clips. Then, a complete ATmega1281-based microcontroller platform has been described for performing computational tasks of signal processing and wireless transmission. In the next section remarks have been provided regarding the basic signal processing rules beginning with raw voltage samples of converted optical signals, their acquisition, storage and smoothing. This chapter ends with practical remarks demonstrating an exponential dependence between the minimum measurable heart rate and the readout resolution at different sampling frequencies for different cases of averaging depth (in bits). The following section is devoted strictly to the heart rate and hemoglobin oxygenation (saturation) measurement with the use of the presented platform, referenced to measurements obtained with a stationary certified pulsoxymeter.

  16. Optimization of high count rate event counting detector with Microchannel Plates and quad Timepix readout

    Energy Technology Data Exchange (ETDEWEB)

    Tremsin, A.S., E-mail: ast@ssl.berkeley.edu; Vallerga, J.V.; McPhate, J.B.; Siegmund, O.H.W.

    2015-07-01

    Many high resolution event counting devices process one event at a time and cannot register simultaneous events. In this article a frame-based readout event counting detector consisting of a pair of Microchannel Plates and a quad Timepix readout is described. More than 10{sup 4} simultaneous events can be detected with a spatial resolution of ~55 µm, while >10{sup 3} simultaneous events can be detected with <10 µm spatial resolution when event centroiding is implemented. The fast readout electronics is capable of processing >1200 frames/sec, while the global count rate of the detector can exceed 5×10{sup 8} particles/s when no timing information on every particle is required. For the first generation Timepix readout, the timing resolution is limited by the Timepix clock to 10–20 ns. Optimization of the MCP gain, rear field voltage and Timepix threshold levels are crucial for the device performance and that is the main subject of this article. These devices can be very attractive for applications where the photon/electron/ion/neutron counting with high spatial and temporal resolution is required, such as energy resolved neutron imaging, Time of Flight experiments in lidar applications, experiments on photoelectron spectroscopy and many others.

  17. Simulating the Counting Mechanism of PILATUS2 and PILATUS3 Detectors for Improved Count Rate Corrections

    Science.gov (United States)

    Trueb, P.; Sobott, B. A.; Schnyder, R.; Loeliger, T.; Schneebeli, M.; Kobas, M.; Rassool, R. P.; Peake, D. J.; Broennimann, C.

    2013-03-01

    PILATUS systems are well established as X-ray detectors at most synchrotrons. Their single photon counting capability ensures precise measurements, but introduces a short dead time after each hit, which becomes significant for photon rates above a million per second and pixel. The resulting loss in the number of counted photons can be corrected for by applying corresponding rate correction factors. This article presents a Monte-Carlo simulation, which computes the correction factors taking into account the detector settings as well as the time structure of the X-ray beam at the synchrotron. For the PILATUS2 detector series the simulation shows good agreement with experimentally determined correction factors for various detector settings at different synchrotrons. The application of more accurate rate correction factors will improve the X-ray data quality at high photon fluxes. Furthermore we report on the simulation of the rate correction factors for the new PILATUS3 systems. The successor of the PILATUS2 detector avoids the paralysation of the counter, and allows for measurements up to a rate of ten million photons per second and pixel. For fast detector settings the simulation is capable of reproducing the data within one to two percent at an incoming photon rate of one million per second and pixel.

  18. Counting

    Institute of Scientific and Technical Information of China (English)

    许有国

    2005-01-01

    Most people began to count in tens because they had ten fingers on their hands. But in some countries, people counted on one hand and used the three parts of their four fingers. So they counted in twelves, not in tens.

  19. Atmospheric sugar alcohols: evaporation rates and saturation vapor pressures

    DEFF Research Database (Denmark)

    Bilde, Merete; Zardini, Alessandro Alessio; Hong, Juan

    are allowed to evaporate in a laminar flow reactor, and changes in particle size as function of evaporation time are determined using a scanning mobility particle sizer system. In this work saturation vapor pressures of sugar alcohols at several temperatures have been inferred from such measurements using...

  20. Atmospheric sugar alcohols: evaporation rates and saturation vapor pressures

    Science.gov (United States)

    Bilde, M.; Zardini, A. A.; Hong, J.; Tschiskale, M.; Emanuelsson, E.

    2014-12-01

    The atmospheric partitioning between gas and condensed phase of organic molecules is poorly understood, and discrepancies exist between predicted and observed concentrations of secondary organic aerosols. A key problem is the lack of information about thermodynamic properties of semi- and low volatile organic molecules. Saturation vapor pressure and the associated temperature dependence (dH) are key parameters for improving predictive atmospheric models. In this work we combine experiments and thermodynamic modeling to investigate these parameters for a series of polyols, so-called sugar alcohols. These polyols are common in the water soluble fraction of atmospheric aerosols. In our experimental system sub-micron particles are generated by nebulization from aqueous solution, and a mono disperse fraction of the aerosol is selected using a differential mobility analyzer. The particles are allowed to evaporate in a laminar flow reactor, and changes in particle size as function of evaporation time are determined using a scanning mobility particle sizer system. In this work saturation vapor pressures of sugar alcohols at several temperatures have been inferred from such measurements using thermodynamic modeling. Results are presented and discussed in context of atmospheric gas to particle partitioning.

  1. Atmospheric sugar alcohols: evaporation rates and saturation vapor pressures

    DEFF Research Database (Denmark)

    Bilde, Merete; Zardini, Alessandro Alessio; Hong, Juan

    volatile organic molecules. Saturation vapor pressure and the associated temperature dependence (dH) are key parameters for improving predictive atmospheric models. In this work we combine experiments and thermodynamic modeling to investigate these parameters for a series of polyols, so-called sugar......The atmospheric partitioning between gas and condensed phase of organic molecules is poorly understood, and discrepancies exist between predicted and observed concentrations of secondary organic aerosols. A key problem is the lack of information about thermodynamic properties of semi- and low...... alcohols. These polyols are common in the water soluble fraction of atmospheric aerosols. In our experimental system sub-micron particles are generated by nebulization from aqueous solution, and a mono disperse fraction of the aerosol is selected using a differential mobility analyzer. The particles...

  2. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  3. Multipixel silicon avalanche photodiode with ultralow dark count rate at liquid nitrogen temperature.

    Science.gov (United States)

    Akiba, M; Tsujino, K; Sato, K; Sasaki, M

    2009-09-14

    Multipixel silicon avalanche photodiodes (Si APDs) are novel photodetectors used as silicon photomultipliers (SiPMs), or multipixel photon counter (MPPC), because they have fast response, photon-number resolution, and a high count rate; one drawback, however, is the high dark count rate. We developed a system for cooling an MPPC to liquid nitrogen temperature and thus reduce the dark count rate. Our system achieved dark count rates of <0.2 cps. Here we present the afterpulse probability, counting capability, timing jitter, and photon-number resolution of our system at 78.5 K and 295 K.

  4. Platelet counts, MPV and PDW in culture proven and probable neonatal sepsis and association of platelet counts with mortality rate.

    Science.gov (United States)

    Ahmad, Mirza Sultan; Waheed, Abdul

    2014-05-01

    To determine frequency of thrombocytopenia and thrombocytosis, the MPV (mean platelet volume) and PDW (platelet distribution width) in patients with probable and culture proven neonatal sepsis and determine any association between platelet counts and mortality rate. Descriptive analytical study. NICU, Fazle Omar Hospital, from January 2011 to December 2012. Cases of culture proven and probable neonatal sepsis, admitted in Fazle Omar Hospital, Rabwah, were included in the study. Platelet counts, MPV and PDW of the cases were recorded. Mortality was documented. Frequencies of thrombocytopenia ( 450000/mm3) were ascertained. Mortality rates in different groups according to platelet counts were calculated and compared by chi-square test to check association. Four hundred and sixty nine patients were included; 68 (14.5%) of them died. One hundred and thirty six (29%) had culture proven sepsis, and 333 (71%) were categorized as probable sepsis. Thrombocytopenia was present in 116 (24.7%), and thrombocytosis was present in 36 (7.7%) cases. Median platelet count was 213.0/mm3. Twenty eight (27.7%) patients with thrombocytopenia, and 40 (12.1%) cases with normal or raised platelet counts died (p neonatal sepsis. Those with thrombocytopenia have higher mortality rate. No significant difference was present between PDW and MPV of the cases who survived and died.

  5. Reducing the Child Poverty Rate. KIDS COUNT Indicator Brief

    Science.gov (United States)

    Shore, Rima; Shore, Barbara

    2009-01-01

    In 2007, nearly one in five or 18 percent of children in the U.S. lived in poverty (KIDS COUNT Data Center, 2009). Many of these children come from minority backgrounds. African American (35 percent), American Indian (33 percent) and Latino (27 percent) children are more likely to live in poverty than their white (11 percent) and Asian (12…

  6. HEART-RATE-VARIABILITY SPECTRA BASED ON NONEQUIDISTANT SAMPLING - THE SPECTRUM OF COUNTS AND THE INSTANTANEOUS HEART-RATE SPECTRUM

    NARCIS (Netherlands)

    VANSTEENIS, HG; TULEN, JHM; MULDER, LJM

    1994-01-01

    This paper compares two methods to estimate heart rate variability spectra i.e., the spectrum of counts and the instantaneous heart rate spectrum. Contrary to Fourier techniques based on equidistant sampling of the interbeat intervals, the spectrum of counts of the instantaneous heart rate spectrum

  7. HEART-RATE-VARIABILITY SPECTRA BASED ON NONEQUIDISTANT SAMPLING - THE SPECTRUM OF COUNTS AND THE INSTANTANEOUS HEART-RATE SPECTRUM

    NARCIS (Netherlands)

    VANSTEENIS, HG; TULEN, JHM; MULDER, LJM

    This paper compares two methods to estimate heart rate variability spectra i.e., the spectrum of counts and the instantaneous heart rate spectrum. Contrary to Fourier techniques based on equidistant sampling of the interbeat intervals, the spectrum of counts of the instantaneous heart rate spectrum

  8. High-Temperature Studies of Glass Dissolution Rates Close to Saturation

    Energy Technology Data Exchange (ETDEWEB)

    Zavarin, M; Roberts, S; Zhao, P; Williams, R; Rose, T; Rainer, A; Pawloski, G

    2004-06-14

    Most long-lived radionuclides associated with an underground nuclear test are incorporated into a melt glass and are released by glass dissolution to become part of the hydrologic source term (HST) (Pawloski et al., 2001). Although the rates of rhyolite glass dissolution are well known under conditions where the fluid is far from saturation with respect to glass, the rates are not well known under conditions where the fluid approaches saturation. These rates are commonly much lower than the far-fromsaturation rates, often by a factor greater than 100. In recent HST simulations (Pawloski et al., 2001; Pawloski et al., 2000; Tompson et al., 1999), we conservatively estimated steady-state release rates based on a far-from-saturation fluid conditions. In recent CHESHIRE near-field simulations (Pawloski et al., 2001), it was predicted that {approx}30% of the nuclear melt glass dissolved over 1000 years. Although the ''far-from-saturation rate'' approach provides a conservative estimate of glass dissolution, it may greatly overestimate the rates of melt glass dissolution. At CHESHIRE, less conservative estimates suggest that only {approx}1% of the nuclear melt glass will dissolve in 1000 years. Lower glass dissolution rates result in lower radionuclide release rates from nuclear melt glass. The following report documents glass dissolution experiments performed to measure glass dissolution rates close to saturation.

  9. General Theory of Decoy-State Quantum Cryptography with Dark Count Rate Fluctuation

    Institute of Scientific and Technical Information of China (English)

    GAO Xiang; SUN Shi-Hai; LIANG Lin-Mei

    2009-01-01

    The existing theory of decoy-state quantum cryptography assumes that the dark count rate is a constant, but in practice there exists fluctuation. We develop a new scheme of the decoy state, achieve a more practical key generation rate in the presence of fluctuation of the dark count rate, and compare the result with the result of the decoy-state without fluctuation.It is found that the key generation rate and maximal secure distance will be decreased under the influence of the fluctuation of the dark count rate.

  10. Impact of stretching-segment on saturated flow rate of signalized intersection using cellular automation

    Institute of Scientific and Technical Information of China (English)

    李岩; 陈宽民; 过秀成

    2013-01-01

    In order to analyze the impact of stretching-segment on the saturated flow rate of signalized intersection approach, an improved cellular automation model was proposed to estimate its saturated flow rate. The NaSch model was improved by adding different slow probabilities, turning deceleration rules and modified lane changing rules. The relationship between the saturated flow rate of stretching-segments and adjacent lanes was tested in numerical simulation. The length of stretching-segment, cycle length and green time were selected as impact factors of the cellular automation model. The simulation result indicates that the geometrics design of stretching-segment and the traffic signal timing scenario have major effects on the saturated flow rate of the intersection approach. The saturated flow rate will continually increase with increasing stretching-segment length until it reaches a threshold. After reaching the threshold, the stretching-segment can be treated as a separate lane. The green time is approximately linearly related to the threshold length of the stretching-segment. An optimum cycle length exists when the length of the stretching-segment is not long enough, and it is approximately linearly related to the length of stretching-segment.

  11. Count rate performance study of the Lausanne ClearPET scanner demonstrator

    Energy Technology Data Exchange (ETDEWEB)

    Rey, M. [LPHE, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland)]. E-mail: martin.rey@epfl.ch; Jan, S. [Service Hospitalier Frederic Joliot, CEA, F-91401 Orsay (France); Vieira, J.-M. [LPHE, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Mosset, J.-B. [LPHE, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Krieguer, M. [IIHE, Vrije Universiteit Brussel, B-1050 Brussels (Belgium); Comtat, C. [Service Hospitalier Frederic Joliot, CEA, F-91401 Orsay (France); Morel, C. [CPPM, CNRS-IN2P3, Universite de la Mediterranee Aix-Marseille II, F-13288 Marseille (France)

    2007-02-01

    This paper presents the count rate measurements obtained with the Lausanne partial ring ClearPET scanner demonstrator and compares them against GATE Monte Carlo simulations. For the present detector setup, a maximum single event count rate of 1.1 Mcps is measured or a 250-750 keV energy window. This corresponds to a coincidence count rate of approximately 22 kcps. Good agreements are observed between measured and simulated data. Count rate performance, including Noise Equivalent Count (NEC) curves, are determined and extrapolated for a full ring ClearPET design using GATE Monte Carlo simulations. For a full ring design with three rings of detector modules, NEC is peaking at about 70 kcps for 20 MBq.

  12. Instrumental oscillations in RHESSI count rates during solar flares

    CERN Document Server

    Inglis, A R; Dennis, B R; Kontar, E P; Nakariakov, V M; Struminsky, A B; Tolbert, A K

    2011-01-01

    Aims: We seek to illustrate the analysis problems posed by RHESSI spacecraft motion by studying persistent instrumental oscillations found in the lightcurves measured by RHESSI's X-ray detectors in the 6-12 keV and 12-25 keV energy range during the decay phase of the flares of 2004 November 4 and 6. Methods: The various motions of the RHESSI spacecraft which may contribute to the manifestation of oscillations are studied. The response of each detector in turn is also investigated. Results: We find that on 2004 November 6 the observed oscillations correspond to the nutation period of the RHESSI instrument. These oscillations are also of greatest amplitude for detector 5, while in the lightcurves of many other detectors the oscillations are small or undetectable. We also find that the variation in detector pointing is much larger during this flare than the counterexample of 2004 November 4. Conclusions: Sufficiently large nutation motions of the RHESSI spacecraft lead to clearly observable oscillations in count...

  13. Note: A high count rate real-time digital processing method for PGNAA data acquisition system

    Science.gov (United States)

    Liu, Yuzhe; Chen, Lian; Li, Feng; Liang, Futian; Jin, Ge

    2017-07-01

    The prompt gamma neutron activation analysis (PGNAA) technique is a real-time online method to analyze the composition of industrial materials. This paper presents a data acquisition system with a high count rate and real-time digital processing method for PGNAA. Limited by the decay time of the detector, the ORTEC multi-channel analyzer (MCA) can normally achieve an average count rate of 100 kcps. However, this system uses an electrical technique to increase the average count rate and reduce dead time, and guarantees good accuracy. Since the measuring time is usually limited to about 120 s, in order to accelerate the accumulation rate of spectrum and reduce the statistical error, the average count rate is expected to reach more than 500 kcps.

  14. Quantum-counting CT in the regime of count-rate paralysis: introduction of the pile-up trigger method

    Science.gov (United States)

    Kappler, S.; Hölzer, S.; Kraft, E.; Stierstorfer, K.; Flohr, T.

    2011-03-01

    The application of quantum-counting detectors in clinical Computed Tomography (CT) is challenged by extreme X-ray fluxes provided by modern high-power X-ray tubes. Scanning of small objects or sub-optimal patient positioning may lead to situations where those fluxes impinge on the detector without attenuation. Even in operation modes optimized for high-rate applications, with small pixels and high bias voltage, CdTe/CdZnTe detectors deliver pulses in the range of several nanoseconds. This can result in severe pulse pile-up causing detector paralysis and ambiguous detector signals. To overcome this problem we introduce the pile-up trigger, a novel method that provides unambiguous detector signals in rate regimes where classical rising-edge counters run into count-rate paralysis. We present detailed CT image simulations assuming ideal sensor material not suffering from polarization effects at high X-ray fluxes. This way we demonstrate the general feasibility of the pile-up trigger method and quantify resulting imaging properties such as contrasts, image noise and dual-energy performance in the high-flux regime of clinical CT devices.

  15. Bone and gallium scans in mastocytosis: correlation with count rates, radiography, and microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ensslen, R.D. (Cross Cancer Inst., Edmonton, Alberta); Jackson, F.I.; Reid, A.M.

    1983-07-01

    Mastocytosis (urticaria pigmentosa) was proven in a patient suffering from severe back pain. A bone scan showed diffusely increased bone activity. Count rates were also abnormally elevated over several areas of the skeleton. Radiographs were consistent with mastocytosis in bone.

  16. Magnesite growth rates as a function of temperature and saturation state

    Science.gov (United States)

    Saldi, Giuseppe D.; Jordan, Guntram; Schott, Jacques; Oelkers, Eric H.

    2009-10-01

    Magnesite growth rates and step velocities have been measured systematically as a function of temperature from 80 to 105 °C and saturation state in 0.1 M NaCl solutions using hydrothermal atomic force microscopy (HAFM). The observations indicate that at these conditions magnesite precipitation is dominated by the coupling of step generation via spiral growth at screw dislocations and step advancement away from these dislocations. As these two processes occur in series the slowest of these dominates precipitation rates. At 100 °C magnesite growth rates ( r) determined by HAFM are consistent with r=k(Ω-1)2, where k is a constant equal to 6.5 × 10 -16 mol/cm 2/s and Ω is the saturation index with respect to magnesite. This equation is consistent with spiral growth step generation controlling magnesite precipitation rates. Corresponding magnesite precipitation rates measured using mixed-flow reactors are shown to be consistent with both the rates measured by HAFM and the spiral growth theory, confirming the rate limiting mechanism. Step advancement, however, is observed to slow far faster than step generation with decreasing temperature; the activation energy for step advancement is 159 kJ/mol whereas step generation rates have an estimated activation energy of ˜60 kJ/mol. As such, it seems likely that at ambient temperatures magnesite growth is limited by very slow step advancement rates.

  17. Nanosecond laser ablation of bulk Al, Bronze, and Cu: ablation rate saturation and laserinduced oxidation

    OpenAIRE

    R. Maisterrena-Epstein; S. Camacho-López; L. Escobar-Alarcón; M. A. Camacho-López

    2007-01-01

    In this work we report about the characteristics of nanosecond laser ablation, in atmospheric air, of bulk Al, Bronze, and Cu. Average per pulse laser ablation rate and its dependence on ablation depth is presented for these three metals. We will demonstrate and discuss some distinctive features of the ablation saturation effect of the above metals. We will also present results on laser-induced oxidation of the metals which results off the ablation event. We studied the laser-induced oxidatio...

  18. The additive nonparametric and semiparametric Aalen model as the rate function for a counting process

    DEFF Research Database (Denmark)

    Scheike, Thomas Harder

    2002-01-01

    We use the additive risk model of Aalen (Aalen, 1980) as a model for the rate of a counting process. Rather than specifying the intensity, that is the instantaneous probability of an event conditional on the entire history of the relevant covariates and counting processes, we present a model...... for the rate function, i.e., the instantaneous probability of an event conditional on only a selected set of covariates. When the rate function for the counting process is of Aalen form we show that the usual Aalen estimator can be used and gives almost unbiased estimates. The usual martingale based variance...... estimator is incorrect and an alternative estimator should be used. We also consider the semi-parametric version of the Aalen model as a rate model (McKeague and Sasieni, 1994) and show that the standard errors that are computed based on an assumption of intensities are incorrect and give a different...

  19. A Calibration of NICMOS Camera 2 for Low Count-Rates

    CERN Document Server

    Rubin, D; Amanullah, R; Barbary, K; Dawson, K S; Deustua, S; Faccioli, L; Fadeyev, V; Fakhouri, H K; Fruchter, A S; Gladders, M D; de Jong, R S; Koekemoer, A; Krechmer, E; Lidman, C; Meyers, J; Nordin, J; Perlmutter, S; Ripoche, P; Schlegel, D J; Spadafora, A; Suzuki, N; Project, The Supernova Cosmology

    2015-01-01

    NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z > 1 SNe Ia. Unlike the conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count-rates. However observations at faint count-rates rely on extrapolations. Here instead, we provide a new zeropoint calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with WFC3 in the low count-rate regime using z ~ 1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR SEDs, uniform colors, and their extended nature gives superior signal-to-noise at the same count rate than would stars. The use of extended objects also allows greater tolerances on PSF profiles. We find ST magnitude zeropoints (after the installation of the NICMOS cooling system, NCS) of 25....

  20. A real-time phoneme counting algorithm and application for speech rate monitoring.

    Science.gov (United States)

    Aharonson, Vered; Aharonson, Eran; Raichlin-Levi, Katia; Sotzianu, Aviv; Amir, Ofer; Ovadia-Blechman, Zehava

    2017-03-01

    Adults who stutter can learn to control and improve their speech fluency by modifying their speaking rate. Existing speech therapy technologies can assist this practice by monitoring speaking rate and providing feedback to the patient, but cannot provide an accurate, quantitative measurement of speaking rate. Moreover, most technologies are too complex and costly to be used for home practice. We developed an algorithm and a smartphone application that monitor a patient's speaking rate in real time and provide user-friendly feedback to both patient and therapist. Our speaking rate computation is performed by a phoneme counting algorithm which implements spectral transition measure extraction to estimate phoneme boundaries. The algorithm is implemented in real time in a mobile application that presents its results in a user-friendly interface. The application incorporates two modes: one provides the patient with visual feedback of his/her speech rate for self-practice and another provides the speech therapist with recordings, speech rate analysis and tools to manage the patient's practice. The algorithm's phoneme counting accuracy was validated on ten healthy subjects who read a paragraph at slow, normal and fast paces, and was compared to manual counting of speech experts. Test-retest and intra-counter reliability were assessed. Preliminary results indicate differences of -4% to 11% between automatic and human phoneme counting. Differences were largest for slow speech. The application can thus provide reliable, user-friendly, real-time feedback for speaking rate control practice.

  1. Multi-gigahertz repetition rate ultrafast waveguide lasers mode-locked with graphene saturable absorbers

    Science.gov (United States)

    Obraztsov, P. A.; Okhrimchuk, A. G.; Rybin, M. G.; Obraztsova, E. D.; Garnov, S. V.

    2016-08-01

    We report the development of an approach to build compact waveguide lasers that operate in the stable fundamental mode-locking regime with multigigahertz repetition rates. The approach is based on the use of depressed cladding multi- or single-mode waveguides fabricated directly in the active laser crystal using the femtosecond laser inscription method and a graphene saturable absorber. Using this approach we achieve the stable self-starting mode-locking operation of a diode-pumped waveguide Nd:YAG laser that delivers picosecond pulses at a repetition rate of up to 11.5 GHz with an average power of 12 mW at a central wavelength of 1064 nm. The saturable absorbers are formed through the chemical vapor deposition of single-layer graphene on the output coupler mirror or directly on the end facet of the laser crystal. The stable self-starting mode-locking operation is achieved by controlling the group delay dispersion in the laser cavity with an intracavity interferometer. The method developed for the creation of compact ultrashort pulse laser generators with gigahertz repetition rates can be extended further and applied for the development of compact high-repetition rate lasers that operate at a wide range of IR wavelengths.

  2. Linear-log counting-rate meter uses transconductance characteristics of a silicon planar transistor

    Science.gov (United States)

    Eichholz, J. J.

    1969-01-01

    Counting rate meter compresses a wide range of data values, or decades of current. Silicon planar transistor, operating in the zero collector-base voltage mode, is used as a feedback element in an operational amplifier to obtain the log response.

  3. A prototype High Purity Germanium detector for high resolution gamma-ray spectroscopy at high count rates

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J., E-mail: rjcooper@lbl.gov [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Amman, M.; Luke, P.N. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, K. [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Department of Nuclear Engineering, University of California, Berkeley, CA 94720 (United States)

    2015-09-21

    Where energy resolution is paramount, High Purity Germanium (HPGe) detectors continue to provide the optimum solution for gamma-ray detection and spectroscopy. Conventional large-volume HPGe detectors are typically limited to count rates on the order of ten thousand counts per second, however, limiting their effectiveness for high count rate applications. To address this limitation, we have developed a novel prototype HPGe detector designed to be capable of achieving fine energy resolution and high event throughput at count rates in excess of one million counts per second. We report here on the concept, design, and initial performance of the first prototype device.

  4. Global dynamics of a vector-borne disease model with latency and saturating incidence rate

    Directory of Open Access Journals (Sweden)

    Ashrafur Rahman

    2014-06-01

    Full Text Available This paper deals with a vector-borne disease model containing latency and nonlinear incidence rates. Global analysis is completely determined by suitable Lyapunov functionals. We explicitely determine the basic reproduction number and find that if this number is less than one then disease dies out, but if the number is larger than one, the disease causing strain become endemic. The study shows that the latency delay explicitely in°uence the disease persistence. Keywords: Latency, saturating incidence, basic reproduction number, global attractivity, Lyapunov functionals.

  5. Existence of Traveling Waves for a Delayed SIRS Epidemic Diffusion Model with Saturation Incidence Rate

    OpenAIRE

    Kai Zhou; Qi-Ru Wang

    2014-01-01

    This paper is concerned with the existence of traveling waves for a delayed SIRS epidemic diffusion model with saturation incidence rate. By using the cross-iteration method and Schauder’s fixed point theorem, we reduce the existence of traveling waves to the existence of a pair of upper-lower solutions. By careful analyzsis, we derive the existence of traveling waves connecting the disease-free steady state and the endemic steady state through the establishment of the suitable upper-lower...

  6. An automatic attenuator device for x-ray detectors at high counting rate

    Science.gov (United States)

    Alvarez, J.; Paiser, E.; Capitan, M. J.

    2002-07-01

    In this article we describe an attenuator device for reducing/controlling the pulse detector counting losses at a high counting rate. The electronics are based on a direct measure of the detector dead time from the analog output signal at the end of the detection chain. Taking into account this parameter the attenuator device decides to reduce/enhance the number of photons that arrive at the detector by inserting/extracting the necessary number of attenuation foils in the x-ray beam path. In that way the number of events in the incoming signal are reduced and the "apparent dynamic range" of the detector is increased.

  7. Statistical analysis of dark count rate in Geiger-mode APD FPAs

    Science.gov (United States)

    Itzler, Mark A.; Krishnamachari, Uppili; Chau, Quan; Jiang, Xudong; Entwistle, Mark; Owens, Mark; Slomkowski, Krystyna

    2014-10-01

    We present a temporal statistical analysis of the array-level dark count behavior of Geiger-mode avalanche photodiode (GmAPD) focal plane arrays that distinguishes between Poissonian intrinsic dark count rate and non-Poissonian crosstalk counts by considering "inter-arrival" times between successive counts from the entire array. For 32 x 32 format sensors with 100 μm pixel pitch, we show the reduction of crosstalk for smaller active area sizes within the pixel. We also compare the inter-arrival time behavior for arrays with narrow band (900 - 1100 nm) and broad band (900 - 1600 nm) spectral response. We then consider a similar analysis of larger format 128 x 32 arrays. As a complement to the temporal analysis, we describe the results of a spatial analysis of crosstalk events. Finally, we propose a simple model for the impact of crosstalk events on the Poissonian statistics of intrinsic dark counts that provides a qualitative explanation for the results of the inter-arrival time analysis for arrays with varying degrees of crosstalk.

  8. Variable structure strategy to avoid amplitude and rate saturation in pitch control of a wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Garelli, Fabricio; Camocardi, Pablo [CONICET, LEICI, Depto. Electrotecnia, Facultad de Ingenieria, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900), La Plata (Argentina); Mantz, Ricardo J. [CICpBA, LEICI, Depto. Electrotecnia, Facultad de Ingenieria, Universidad Nacional de La Plata, 1 y 47, CC 91 (1900), La Plata (Argentina)

    2010-06-15

    This work proposes the application of a recent compensation technique for input constraints avoidance to the pitch control of a wind turbine. The pitch angle actuators commonly present a hard limit on their rate of change together with the natural amplitude saturation, and a dynamics during their unconstrained operation that can be modeled as a first-order linear system. This dynamic behavior of the pitch actuator requires a particular design of the compensation method, which is based on variable structure systems to avoid both amplitude and rate input saturation by means of an auxiliary loop. The developed methodology reduces the pitch actuator activity necessary to regulate the generated power around its nominal value when facing sudden wind gusts. Another interesting feature of the proposal is that it allows the operator to fix conservative bounds for the actuator speed operation in order to increment the structural robustness of the wind turbine and to extend in this way the service life of the energy system. The effectiveness of the proposed strategy is evaluated by simulation results in an autonomous wind energy conversion system for water pumping with a brushless double feed induction generator (BDFIG). (author)

  9. Solar models of low neutrino-counting rate - The depleted Maxwellian tail

    Science.gov (United States)

    Clayton, D. D.; Dwek, E.; Newman, M. J.; Talbot, R. J., Jr.

    1975-01-01

    Evolutionary sequences for the sun are presented which confirm that the Cl-37 neutrino counting rate will be greatly reduced if the high-energy tail of the Maxwellian distribution of relative energies is progressively depleted. Thermonuclear reaction rates and pressure are reevaluated for a distribution function modified by the correction factor suggested by Clayton (1974), and the effect of the results on solar models calculated with a simple Henyey code is discussed. It is shown that if the depletion is characterized by a certain exponential dependence on the distribution function, the counting rate will fall below 1 SNU for a distribution function of not less than 0.01. Suggestions are made for measuring the distribution function in the sun by means of neutrino spectroscopy and photography.

  10. Dose and dose rate effects of irradiation on blood count and cytokine assay in mice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joong Sun [Research center, Dongnam institute of radiological and Medical Sciences (DIRAMS), Busan (Korea, Republic of)

    2013-11-15

    The possible role of exposure to radiation as a risk factor for human health has been of increasing public concern in the series of explosions at earthquake damaged nuclear reactors on the Japan. Current events throughout the world underscore the growing threat of different forms of accidental exposure to radiation including nuclear accidents, atomic weapons use and testing, and the side effects of cancer therapy. A large range of dose rates of ionizing radiations could be encountered in accidental radiation situations. Nevertheless, most of the studies related to radiation effects have only examined a high dose rate. In this study, we investigated the blood count and the cytokine levels in the serum of mice exposed to a high or low dose rate of radiation. In this study, the precise molecular mechanism underlying the low dose rate of radiation remains unclear, but differential hematopoietic effects of radiation exposed at a high dose rate versus low dose rate were observed using the number of peripheral blood count and serum cytokines. These data suggest that chronic low dose rate exposure caused a stimulation of heamatopoietic system occurrence, unlike those observed after higher dose rate exposure. Our data suggest that the dose rate, rather than the total dose, may be more critical in causing damage to the cellular hematopoietic compartments of the body.

  11. Improved count rate corrections for highest data quality with PILATUS detectors.

    Science.gov (United States)

    Trueb, P; Sobott, B A; Schnyder, R; Loeliger, T; Schneebeli, M; Kobas, M; Rassool, R P; Peake, D J; Broennimann, C

    2012-05-01

    The PILATUS detector system is widely used for X-ray experiments at third-generation synchrotrons. It is based on a hybrid technology combining a pixelated silicon sensor with a CMOS readout chip. Its single-photon-counting capability ensures precise and noise-free measurements. The counting mechanism introduces a short dead-time after each hit, which becomes significant for rates above 10(6) photons s(-1) pixel(-1). The resulting loss in the number of counted photons is corrected for by applying corresponding rate correction factors. This article presents the results of a Monte Carlo simulation which computes the correction factors taking into account the detector settings as well as the time structure of the X-ray beam at the synchrotron. The results of the simulation show good agreement with experimentally determined correction factors for various detector settings at different synchrotrons. The application of accurate rate correction factors improves the X-ray data quality acquired at high photon fluxes. Furthermore, it is shown that the use of fast detector settings in combination with an optimized time structure of the X-ray beam allows for measurements up to rates of 10(7) photons s(-1) pixel(-1).

  12. Characteristic Count Rate Profiles for a Rotating Modulator Gamma-Ray Imager

    CERN Document Server

    Budden, Brent S; Case, Gary L; Cherry, Michael L

    2011-01-01

    Rotating modulation is a technique for indirect imaging in the hard x-ray and soft gamma-ray energy bands, which may offer an advantage over coded aperture imaging at high energies. A rotating modulator (RM) consists of a single mask of co-planar parallel slats typically spaced equidistance apart, suspended above an array of circular non-imaging detectors. The mask rotates, temporally modulating the transmitted image of the object scene. The measured count rate profiles of each detector are folded modulo the mask rotational period, and the object scene is reconstructed using pre-determined characteristic modulation profiles. The use of Monte Carlo simulation to derive the characteristic count rate profiles is accurate but computationally expensive; an analytic approach is preferred for its speed of computation. We present both the standard and a new advanced characteristic formula describing the modulation pattern of the RM; the latter is a more robust description of the instrument response developed as part ...

  13. Use of Feedback to Maximize Photon Count Rate in XRF Spectroscopy

    CERN Document Server

    Lucas, Benjamin A

    2016-01-01

    The effective bandwidth of an energy dispersive x-ray fluorescence spectroscopy system is limited by the timing of incident photons. When multiple photons strike the detector within the processing time of the detector photon pile-up occurs and the signal received by the detector during this interval must be ignored. In conventional ED-XRF systems the probability of a photon being incident upon the detector is uniform over time, and thus pile-up follows Poisson statistics. In this paper we present a mathematical treatment of the relationship between photon timing statistics and the count rate of an XRF system. We show that it is possible to increase the maximum count rates by applying feedback from the detector to the x-ray source to alter the timing statistics of photon emission. Monte-Carlo simulations, show that this technique can increase the maximum count rate of an XRF spectroscopy system by a factor of 2.94 under certain circumstances.

  14. An SIRS Epidemic Model with Vital Dynamics and a Ratio-Dependent Saturation Incidence Rate

    Directory of Open Access Journals (Sweden)

    Xinli Wang

    2015-01-01

    Full Text Available This paper presents an investigation on the dynamics of an epidemic model with vital dynamics and a nonlinear incidence rate of saturated mass action as a function of the ratio of the number of the infectives to that of the susceptibles. The stabilities of the disease-free equilibrium and the endemic equilibrium are first studied. Under the assumption of nonexistence of periodic solution, the global dynamics of the model is established: either the number of infective individuals tends to zero as time evolves or it produces bistability in which there is a region such that the disease will persist if the initial position lies in the region and disappears if the initial position lies outside this region. Computer simulation shows such results.

  15. Investigation of Detector Behaviour At High Count Rates for the Purple Crow Lidar

    Science.gov (United States)

    Sica, R. J.; McCullough, E. M.; Jalali, A.; Hartery, S.; Farhani, G.; Argall, P.; Argall, S.

    2013-12-01

    Temperature measurements in the middle and upper atmosphere are an important complement to similar measurements in the lower atmosphere. Even modest size Rayleigh-scatter lidars are capable of high quality measurements of temperature in the stratosphere (above 25 km) and lower mesosphere. The most commonly reported uncertainty, that due to counting statistics, is well understood and affects temperatures at the greatest heights (i.e. lowest signal rates). Counting statistics have a lesser effect on temperatures at the lower range of measurements, where the photocount rate is larger. However, if a lidar's dynamic range is increased by combining analog and digital counting profiles into a 'glued' profile, the gluing introduces a systematic uncertainty. In this presentation we will show the effect of the uncertainty due to gluing on our temperature measurements. The Purple Crow Lidar (PCL), located at the The University of Western Ontario's Echo Base Field Station near London, Canada, has undergone considerable modifications to its transmitter (now a Litron Nd:YAG laser outputting 1 J/pulse at 532 nm with a repetition rate of 30 Hz) as well as to its data acquisition system. The PCL has retained its 2.6 m diameter liquid mercury mirror, giving the system a large power-aperture product. Such a large throughput requires simultaneous analog-digital detection to obtain Rayleigh-scatter temperatures from 25 to above 100 km. The analog and digital profiles must be combined into a single continuous profile, a process called gluing. Several excellent methods for gluing profiles have been presented, but prior to now systematic uncertainties due to the procedure have not been quantified. We will present a detailed characterization of the analog and digital counting channels, using a variety of tests which will show the effect of the gluing procedure on the retrieved temperature.

  16. From the surface to the deep critical zone: Linking soil carbon, fluid saturation and weathering rate

    Science.gov (United States)

    Druhan, Jennifer; Lawrence, Corey; Oster, Jessica; Rempe, Daniella; Dietrich, William

    2017-04-01

    Shallow soils from a wide range of ecosystems demonstrate a clear and consistent relationship between effective fluid saturation and the rate at which organic carbon is converted to CO2. While the underlying mechanisms contributing to this dependence are diverse, a consistent pattern of maximum CO2 production at intermediate soil moisture supports a generalized functional relationship, which may be incorporated into a quantitative reactive transport framework. A key result of this model development is a prediction of the extent to which the inorganic carbon content of water in biologically active soils varies as a function of hydrologic parameters (i.e. moisture content and residence time), and in turn influences weathering reactions. Deeper in the CZ, the consistency of this relationship and the influence of hydrologically - regulated CO2 production on the rates of water - rock interaction are largely unknown. Here, we use a novel reactive transport model incorporating this functional relationship to consider how variations in the reactive potential of water entering the vadose zone influences subsurface weathering rates. We leverage two examples of variably saturated natural systems to consider (1) CO2 production and associated weathering potential regulated by seasonal hydrologic shifts and (2) the preservation of soil carbon signatures in the deep CZ over millennial timescales. First, at the Eel River CZ Observatory in Northern California, USA, a novel Vadose Zone Monitoring System (VMS) installed in a 14 - 20 m thick unsaturated section offers an unprecedented view into the physical, chemical and biological behavior of the depth profile separating soils from groundwater. Based on soil moisture, gas and fluid phase samples, we demonstrate a predictive relationship between seasonal hydrologic variations and the location and magnitude of geochemical weathering rates. Second, an environmental monitoring project in the Blue Springs Cave, Sparta, TN, USA, provides

  17. Low-noise multichannel ASIC for high count rate X-ray diffractometry applications

    Energy Technology Data Exchange (ETDEWEB)

    Szczygiel, R. [AGH University of Science and Technology, Department of Measurement and Instrumentation, al. Mickiewicza 30, Krakow (Poland)], E-mail: robert.szczygiel@agh.edu.pl; Grybos, P.; Maj, P. [AGH University of Science and Technology, Department of Measurement and Instrumentation, al. Mickiewicza 30, Krakow (Poland); Tsukiyama, A.; Matsushita, K.; Taguchi, T. [Rigaku Corporation, 3-9-12 Matsubara-cho, Akishima-shi, Tokyo (Japan)

    2009-08-01

    RG64 is a 64-channel ASIC designed for the silicon strip detector readout and optimized for high count rate X-ray imaging applications. In this paper we report on the test results referring to the RG64 noise level, channel uniformity and the operation with a high rate of input signals. The parameters of the RG64-based diffractometry system are compared with the ones based on the scintillation counter. Diffractometry measurement results with silicon strip detectors of different strip lengths and strip pitch are also presented.

  18. Gamma spectrum, count rate, and dose rate measurements of the Columbia riverbank from Vernita to Sacajawea

    Energy Technology Data Exchange (ETDEWEB)

    Grande, L.A.

    1966-01-31

    The purpose of this study was to evaluate radiological conditions that exist on the riverbank of the Columbia River. Included was a comparative study of the suitability of three instruments to measure the dose rates. These instruments were a NaI (T1) scintillation counter normally used for aerial monitoring, a bioplastic scintillation counter normally used as a road monitor, and a portable 40 liter ionization chamber normally used to measure very low gamma dose rates. The selection of representative sites for the comparative study was based on an initial GM survey of the general areas in question. Seven sites were studied--from Vernita Ferry Landing above the Hanford project to Sacajawea Park below Pasco.

  19. Effects of Breast Milk and Vanilla Odors on Premature Neonate's Heart Rate and Blood Oxygen Saturation During and After Venipuncture.

    Science.gov (United States)

    Neshat, Hanieh; Jebreili, Mahnaz; Seyyedrasouli, Aleheh; Ghojazade, Morteza; Hosseini, Mohammad Bagher; Hamishehkar, Hamed

    2016-06-01

    Different studies have shown that the use of olfactory stimuli during painful medical procedures reduces infants' response to pain. The main purpose of the current study was to investigate the effect of breast milk odor and vanilla odor on premature infants' vital signs including heart rate and blood oxygen saturation during and after venipuncture. A total of 135 preterm infants were randomly selected and divided into three groups of control, vanilla odor, and breast milk odor. Infants in the breast milk group and the vanilla group were exposed to breast milk odor and vanilla odor from 5 minutes prior to sampling until 30 seconds after sampling. The results showed that breast milk odor has a significant effect on the changes of neonatal heart rate and blood oxygen saturation during and after venipuncture and decreased the variability of premature infants' heart rate and blood oxygen saturation. Vanilla odor has no significant effect on premature infants' heart rate and blood oxygen saturation. Breast milk odor can decrease the variability of premature infants' heart rate and blood oxygen saturation during and after venipuncture. Copyright © 2015. Published by Elsevier B.V.

  20. Extended Measurement Capabilities of the Electron Proton Helium INstrument aboard SOHO - Understanding single detector count rates

    Science.gov (United States)

    Kühl, P.; Banjac, S.; Heber, B.; Labrenz, J.; Müller-Mellin, R.; Terasa, C.

    Forbush (1937) was the first to observe intensity decreases lasting for a few days utilizing ionization chambers. A number of studies on Forbush decreases (FDs) have been performed since then utilizing neutron monitors and space instrumentation. The amplitude of these variations can be as low as a few permil. Therefore intensity measurements need to be of high statistical accuracy. Richardson et al. (1996) suggested therefore to utilize the single counter measurements of the guard counters of the IMP 8 and Helios E6 instruments. Like the above mentioned instruments the Electron Proton Helium INstrument (EPHIN) provides single counting rates. During the extended solar minimum in 2009 its guard detector counted about 25000~counts/minute, allowing to determine intensity variations of less than 2 permil using 30 minute averages. We performed a GEANT 4 simulation of the instrument in order to determine the energy response of all single detectors. It is shown here that their energy thresholds are much lower than the ones of neutron monitors and therefore we developed a criterion that allows to investigate FDs during quiet time periods.

  1. A physics investigation of deadtime losses in neutron counting at low rates with Cf252

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Louise G [Los Alamos National Laboratory; Croft, Stephen [CANBERRA INDUSTRIES, INC.

    2009-01-01

    {sup 252}Cf spontaneous fission sources are used for the characterization of neutron counters and the determination of calibration parameters; including both neutron coincidence counting (NCC) and neutron multiplicity deadtime (DT) parameters. Even at low event rates, temporally-correlated neutron counting using {sup 252}Cf suffers a deadtime effect. Meaning that in contrast to counting a random neutron source (e.g. AmLi to a close approximation), DT losses do not vanish in the low rate limit. This is because neutrons are emitted from spontaneous fission events in time-correlated 'bursts', and are detected over a short period commensurate with their lifetime in the detector (characterized by the system die-away time, {tau}). Thus, even when detected neutron events from different spontaneous fissions are unlikely to overlap in time, neutron events within the detected 'burst' are subject to intrinsic DT losses. Intrinsic DT losses for dilute Pu will be lower since the multiplicity distribution is softer, but real items also experience self-multiplication which can increase the 'size' of the bursts. Traditional NCC DT correction methods do not include the intrinsic (within burst) losses. We have proposed new forms of the traditional NCC Singles and Doubles DT correction factors. In this work, we apply Monte Carlo neutron pulse train analysis to investigate the functional form of the deadtime correction factors for an updating deadtime. Modeling is based on a high efficiency {sup 3}He neutron counter with short die-away time, representing an ideal {sup 3}He based detection system. The physics of dead time losses at low rates is explored and presented. It is observed that new forms are applicable and offer more accurate correction than the traditional forms.

  2. Effects, determination, and correction of count rate nonlinearity in multi-channel analog electron detectors

    Energy Technology Data Exchange (ETDEWEB)

    Reber, T. J.; Plumb, N. C.; Waugh, J. A.; Dessau, D. S. [Department of Physics, University of Colorado, Boulder, Colorado 80309-0390 (United States)

    2014-04-15

    Detector counting rate nonlinearity, though a known problem, is commonly ignored in the analysis of angle resolved photoemission spectroscopy where modern multichannel electron detection schemes using analog intensity scales are used. We focus on a nearly ubiquitous “inverse saturation” nonlinearity that makes the spectra falsely sharp and beautiful. These artificially enhanced spectra limit accurate quantitative analysis of the data, leading to mistaken spectral weights, Fermi energies, and peak widths. We present a method to rapidly detect and correct for this nonlinearity. This algorithm could be applicable for a wide range of nonlinear systems, beyond photoemission spectroscopy.

  3. Study of the counting rate capability of MRPC detectors built with soda lime glass

    Science.gov (United States)

    Forster, R.; Margoto Rodríguez, O.; Park, W.; Rodríguez Rodríguez, A.; Williams, M. C. S.; Zichichi, A.; Zuyeuski, R.

    2016-09-01

    We report the results of three MRPC detectors built with soda lime glass and tested in the T10 beam line at CERN. The detectors consist of a stack of 280 μm thick glass sheets with 6 gaps of 220 μm . We built two identical MRPCs, except one had the edges of glass treated with resistive paint. A third detector was built with one HV electrode painted as strips. The detectors' efficiency and time resolution were studied at different particle flux in a pulsed beam environment. The results do not show any improvement with the painted edge technique at higher particle flux. We heated the MRPCs up to 40 °C to evaluate the influence of temperature in the rate capability. Results from this warming has indicated an improvement on the rate capability. The dark count rates show a significant dependence with the temperature.

  4. Dynamics Analysis and Simulation of a Modified HIV Infection Model with a Saturated Infection Rate

    Directory of Open Access Journals (Sweden)

    Qilin Sun

    2014-01-01

    Full Text Available This paper studies a modified human immunodeficiency virus (HIV infection differential equation model with a saturated infection rate. It is proved that if the basic virus reproductive number R0 of the model is less than one, then the infection-free equilibrium point of the model is globally asymptotically stable; if R0 of the model is more than one, then the endemic infection equilibrium point of the model is globally asymptotically stable. Based on the clinical data from HIV drug resistance database of Stanford University, using the proposed model simulates the dynamics of the two groups of patients’ anti-HIV infection treatment. The numerical simulation results are in agreement with the evolutions of the patients’ HIV RNA levels. It can be assumed that if an HIV infected individual’s basic virus reproductive number R0<1 then this person will recover automatically; if an antiretroviral therapy makes an HIV infected individual’s R0<1, this person will be cured eventually; if an antiretroviral therapy fails to suppress an HIV infected individual’s HIV RNA load to be of unpredictable level, the time that the patient’s HIV RNA level has achieved the minimum value may be the starting time that drug resistance has appeared.

  5. Dynamics of a Delayed HIV-1 Infection Model with Saturation Incidence Rate and CTL Immune Response

    Science.gov (United States)

    Guo, Ting; Liu, Haihong; Xu, Chenglin; Yan, Fang

    2016-12-01

    In this paper, we investigate the dynamics of a five-dimensional virus model incorporating saturation incidence rate, CTL immune response and three time delays which represent the latent period, virus production period and immune response delay, respectively. We begin this model by proving the positivity and boundedness of the solutions. Our model admits three possible equilibrium solutions, namely the infection-free equilibrium E0, the infectious equilibrium without immune response E1 and the infectious equilibrium with immune response E2. Moreover, by analyzing corresponding characteristic equations, the local stability of each of the feasible equilibria and the existence of Hopf bifurcation at the equilibrium point E2 are established, respectively. Further, by using fluctuation lemma and suitable Lyapunov functionals, it is shown that E0 is globally asymptotically stable when the basic reproductive numbers for viral infection R0 is less than unity. When the basic reproductive numbers for immune response R1 is less than unity and R0 is greater than unity, the equilibrium point E1 is globally asymptotically stable. Finally, some numerical simulations are carried out for illustrating the theoretical results.

  6. Oxygen saturation/minute heart rate index: Simple lung function test for children.

    Science.gov (United States)

    Ozdemir, Ali; Dogruel, Dilek; Yilmaz, Ozlem

    2017-02-01

    The severity of airway obstruction can be accurately determined on spirometry in children with asthma. Other assessments may include peak expiratory flow and pulse oximetry. In the present study, we evaluated the validity and reliability of oxygen saturation/minute heart rate (SpO2 /MHR) index in the prediction of degree of severe airway obstruction in children with asthma. This was a retrospective study of children aged 7-17 followed for asthma at Mersin Women and Children's Hospital. The study compared SpO2 /MHR ratio with forced expiratory volume in 1 s (FEV1 ) measured on spirometry, an important indicator of small airway obstruction. A total of 296 patients were included in the study, and classified either as having normal FEV1 (FEV1 > 80% of predicted, n = 178) or severely reduced FEV1 (FEV1 MHR index in predicting low FEV1 were calculated on receiver operating characteristics analysis. An SpO2 /MHR ratio cut-off MHR ratio appears to be a highly useful index to assess airway obstruction in older children with asthma. Thus, it can be used as a marker of airway obstruction severity when spirometry is not available. © 2016 Japan Pediatric Society.

  7. [Usefulness of Determining Acquisition Time by True Count Rate Measurement Method for Delivery 18F-FDG PET/CT].

    Science.gov (United States)

    Miura, Shota; Odashima, Satoshi

    2016-03-01

    A stable quality of delivery 18F-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) requires suitable acquisition time, which can be obtained from an accurate true count of 18F-FDG. However, the true count is influenced by body mass index (BMI) and attenuation of 18F-FDG. In order to remove these influences, we have developed a new method (actual measurement method) to measure the actual true count rate based on sub-pubic thigh, which allows us to calculate a suitable acquisition time. In this study, we aimed to verify the acquisition count through our new method in terms of two categories: (1) the accuracy of acquisition count and (2) evaluation of clinical images using physical index. Our actual measurement method was designed to obtain suitable acquisition time through the following procedure. A true count rate of sub-pubic thigh was measured through detector of PET, and used as a standard true count rate. Finally, the obtained standard count rate was processed to acquisition time. This method was retrospectively applied to 150 patients, receiving 18F-FDG administration from 109.7 to 336.8 MBq, and whose body weight ranged from 37 to 95.4 kg. The accuracy of true count was evaluated by comparing relationships of true count, relative to BMI or to administered dose of 18F-FDG. The PET/CT images obtained by our actual measurement method were assessed using physical index. Our new method resulted in accurate true count, which was not influenced by either BMI or administered dose of 18F-FDG, as well as satisfied PET/CT images with recommended criteria of physical index in all patients.

  8. Effects of dilution rates, animal species and instruments on the spectrophotometric determination of sperm counts.

    Science.gov (United States)

    Rondeau, M; Rouleau, M

    1981-06-01

    Using semen from bull, boar and stallion as well as different spectrophotometers, we established the calibration curves relating the optical density of a sperm sample to the sperm count obtained on the hemacytometer. The results show that, for a given spectrophotometer, the calibration curve is not characteristic of the animal species we studied. The differences in size of the spermatozoa are probably too small to account for the anticipated specificity of the calibration curve. Furthermore, the fact that different dilution rates must be used, because of the vastly different concentrations of spermatozoa which is characteristic of those species, has no effect on the calibration curves since the dilution rate is shown to be artefactual. On the other hand, for a given semen, the calibration curve varies depending upon the spectrophotometry used. However, if two instruments have the same characteristic in terms of spectral bandwidth, the calibration curves are not statistically different.

  9. Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

    CERN Document Server

    Bittner, Bernhard; Kortner, Oliver; Kroha, Hubert; Manfredini, Alessandro; Nowak, Sebastian; Ott, Sebastian; Richter, Robert; Schwegler, Philipp; Zanzi, Daniele; Biebel, Otmar; Hertenberger, Ralf; Ruschke, Alexander; Zibell, Andre

    2016-01-01

    The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking e?ciency and spatial resolution at high counting rates will be achieved with ...

  10. Influence Of Changing the Flow Rate In The Acoustic Response And Saturation During Forced Imbibition In A Limestone

    Science.gov (United States)

    Lopes, S.; Lebedev, M.; Muller, T. M.

    2012-12-01

    Forced imbibition was performed in a Limestone Savonnieres by injecting water into a dry sample. The injection was monitored with X-ray Computed Tomography (CT) and active ultrasonic measurements so that the time-space distribution of the invading fluid could be simultaneously observed in CT images and quantified through measuring P-wave velocities and water saturation. The CT scans allowed us to observe a water front advancing away from the area of injection and estimate saturation. Through the evolution of P-wave velocities, we observed that the approaching of the water front to the monitored position decreased P-wave velocities while the saturation increased continuously. Decreasing injection rate decreased P-wave velocities and saturation. Increasing injection rate, increased P-wave velocities and saturation, sharply and for a short period of time followed by a slight decrease for P-wave velocities and a continuous increase. Our experimental data confirms how sensitive acoustic waves are to the presence of water and that changing injection rates promote considerable fluid distribution that is drastically reflected in the acoustic velocities. Furthermore, the same patterns have been observed in our previous work with sandstones.; Waveforms for the P-waves picked during this experiment: before injection (blue line) and after injecting 8.4 mL of volume of water (orange line). Note the decrease of wave-amplitude and increase of wavelength. ; P-wave velocities with volume of water injected. Dashed lines represent the moments when we decreased injection rate, at 7.9 mL of volume of water injected, and when we increased injection rate at 10.7 mL. Note the immediate decrease and increase of P-wave velocity when we decrease and increase the injection rate, respectively.

  11. Optimization of the ATLAS (s)MDT readout electronics for high counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Kortner, Oliver; Kroha, Hubert; Nowak, Sebastian; Schmidt-Sommerfeld, Korbinian [Max-Planck-Institut fuer Physik (Werner-Heisenberg-Institut), Foehringer Ring 6, 80805 Muenchen (Germany)

    2016-07-01

    In the ATLAS muon spectrometer, Monitored Drift Tube (MDT) chambers are used for precise muon track measurement. For the high background rates expected at HL-LHC, which are mainly due to neutrons and photons produced by interactions of the proton collision products in the detector and shielding, new small-diameter muon drift tube (sMDT)-chambers with half the drift tube diameter of the MDT-chambers and ten times higher rate capability have been developed. The standard MDT readout electronics uses bipolar shaping in front of a discriminator. This shaping leads to an undershoot of same charge but opposite polarity following each pulse. With count rates also the probability of having the subsequent pulse in this undershoot increases, which leads to losses in efficiency and spatial resolution. In order to decrease this effect, discrete prototype electronics including Baseline Restoration has been developed. Results of their tests and data taken with them during muon beamtime measurements at CERN's Gamma Irradiation Facility will be presented. which causes a deterioration of signal pulses by preceding background hits, leading to losses in muon efficiency and drift tube spatial resolution. In order to mitigate these so-called signal pile-up effects, new readout electronics with active baseline restoration (BLR) is under development. Discrete prototype electronics with BLR functionality has been tested in laboratory measurements and in the Gamma Irradiation Facility at CERN under high γ-irradiation rates. Results of the measurements are presented.

  12. A model of the high count rate performance of NaI(Tl)-based PET detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wear, J.A.; Karp, J.S.; Freifelder, R. [Univ. of Pennsylvania, Philadelphia, PA (United States). Dept. of Radiology; Mankoff, D.A. [Univ. of Washington, Seattle, WA (United States). Dept. of Radiology; Muehllehner, G. [UGM Medical Systems, Philadelphia, PA (United States)

    1998-06-01

    A detailed model of the response of large-area NaI(Tl) detectors used in PET and their triggering and data acquisition electronics has been developed. This allows one to examine the limitations of the imaging system`s performance due to degradation in the detector performance from light pile-up and deadtime from triggering and event processing. Comparisons of simulation results to measurements from the HEAD PENN-PET scanner have been performed to validate the Monte Carlo model. The model was then used to predict improvements in the high count rate performance of the HEAD PENN-PET scanner using different signal integration times, light response functions, and detectors.

  13. Two dimensional localization of electrons and positrons under high counting rate

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, A.F.; Anjos, J.C.; Sanchez-Hernandez, A. [Centro Brasileiro de Pesquisas Fisicas (CBPF), Rio de Janeiro, RJ (Brazil); Pepe, I.M.; Barros, N. [Bahia Univ., Salvador, BA (Brazil). Inst. de Fisica

    1997-12-01

    The construction of two wire chambers for the experiment E831 at Fermilab is reported. Each chamber includes three wire planes - one anode and two orthogonal cathodes - in which the wires operate as independent proportional counters. One of the chambers is rotated with respect to the other, so that four position coordinates may be encoded for a charged particle crossing both chambers. Spatial resolution is determined by the wire pitch: 1 mm for cathodes, 2 mm for anodes. 320 electronic channels are involved in the detection system readout. Global counting rates in excess to 10{sup 7} events per second have been measured, while the average electron-positron beam intensity may be as high as 3 x 10{sup 7} events per second. (author) 5 refs., 9 figs.

  14. Nuclear photonics at ultra-high counting rates and higher multipole excitations

    Energy Technology Data Exchange (ETDEWEB)

    Thirolf, P. G.; Habs, D.; Filipescu, D.; Gernhaeuser, R.; Guenther, M. M.; Jentschel, M.; Marginean, N.; Pietralla, N. [Fakultaet f. Physik, Ludwig-Maximilians-Universitaet Muenchen, Garching (Germany); Fakultaet f. Physik, Ludwig-Maximilians-Universitaet Muenchen, Garching, Germany and Max-Planck-Institute f. Quantum Optics, Garching (Germany); IFIN-HH, Bucharest-Magurele (Romania); Physik Department E12,Technische Universitaet Muenchen, Garching (Germany); Max-Planck-Institute f. Quantum Optics, Garching (Germany); Institut Laue-Langevin, Grenoble (France); Physik Department E12,Technische Universitaet Muenchen, Garching (Germany); Institut f. Kernphysik, Technische Universitaet Darmstadt (Germany)

    2012-07-09

    Next-generation {gamma} beams from laser Compton-backscattering facilities like ELI-NP (Bucharest)] or MEGa-Ray (Livermore) will drastically exceed the photon flux presently available at existing facilities, reaching or even exceeding 10{sup 13}{gamma}/sec. The beam structure as presently foreseen for MEGa-Ray and ELI-NP builds upon a structure of macro-pulses ({approx}120 Hz) for the electron beam, accelerated with X-band technology at 11.5 GHz, resulting in a micro structure of 87 ps distance between the electron pulses acting as mirrors for a counterpropagating intense laser. In total each 8.3 ms a {gamma} pulse series with a duration of about 100 ns will impinge on the target, resulting in an instantaneous photon flux of about 10{sup 18}{gamma}/s, thus introducing major challenges in view of pile-up. Novel {gamma} optics will be applied to monochromatize the {gamma} beam to ultimately {Delta}E/E{approx}10{sup -6}. Thus level-selective spectroscopy of higher multipole excitations will become accessible with good contrast for the first time. Fast responding {gamma} detectors, e.g. based on advanced scintillator technology (e.g. LaBr{sub 3}(Ce)) allow for measurements with count rates as high as 10{sup 6}-10{sup 7}{gamma}/s without significant drop of performance. Data handling adapted to the beam conditions could be performed by fast digitizing electronics, able to sample data traces during the micro-pulse duration, while the subsequent macro-pulse gap of ca. 8 ms leaves ample time for data readout. A ball of LaBr{sub 3} detectors with digital readout appears to best suited for this novel type of nuclear photonics at ultra-high counting rates.

  15. Construction and Test of Muon Drift Tube Chambers for High Counting Rates

    CERN Document Server

    Schwegler, Philipp; Dubbert, Jörg

    2010-01-01

    Since the start of operation of the Large Hadron Collider (LHC) at CERN on 20 November 2009, the instantaneous luminosity is steadily increasing. The muon spectrometer of the ATLAS detector at the LHC is instrumented with trigger and precision tracking chambers in a toroidal magnetic field. Monitored Drift-Tube (MDT) chambers are employed as precision tracking chambers, complemented by Cathode Strip Chambers (CSC) in the very forward region where the background counting rate due to neutrons and γ's produced in shielding material and detector components is too high for the MDT chambers. After several upgrades of the CERN accelerator system over the coming decade, the instantaneous luminosity is expected to be raised to about five times the LHC design luminosity. This necessitates replacement of the muon chambers in the regions with the highest background radiation rates in the so-called Small Wheels, which constitute the innermost layers of the muon spectrometer end-caps, by new detectors with higher rate cap...

  16. Note: Fully integrated active quenching circuit achieving 100 MHz count rate with custom technology single photon avalanche diodes

    Science.gov (United States)

    Acconcia, G.; Labanca, I.; Rech, I.; Gulinatti, A.; Ghioni, M.

    2017-02-01

    The minimization of Single Photon Avalanche Diodes (SPADs) dead time is a key factor to speed up photon counting and timing measurements. We present a fully integrated Active Quenching Circuit (AQC) able to provide a count rate as high as 100 MHz with custom technology SPAD detectors. The AQC can also operate the new red enhanced SPAD and provide the timing information with a timing jitter Full Width at Half Maximum (FWHM) as low as 160 ps.

  17. Preamplifier development for high count-rate, large dynamic range readout of inorganic scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Keshelashvili, Irakli; Erni, Werner; Steinacher, Michael; Krusche, Bernd; Collaboration: PANDA-Collaboration

    2013-07-01

    Electromagnetic calorimeter are central component of many experiments in nuclear and particle physics. Modern ''trigger less'' detectors run with very high count-rates, require good time and energy resolution, and large dynamic range. In addition photosensors and preamplifiers must work in hostile environments (magnetic fields). Due to later constraints mainly Avalanche Photo Diodes (APD's), Vacuum Photo Triodes (VPT's), and Vacuum Photo Tetrodes (VPTT's) are used. A disadvantage is their low gain which together with other requirements is a challenge for the preamplifier design. Our group has developed special Low Noise / Low Power (LNP) preamplifier for this purpose. They will be used to equip PANDA EMC forward end-cap (dynamic range 15'000, rate 1MHz), where the PWO II crystals and preamplifier have to run in an environment cooled down to -25{sup o}C. Further application is the upgrade of the Crystal Barrel detector at the Bonn ELSA accelerator with APD readout for which special temperature comparison of the APD gain and good time resolution is necessary. Development and all test procedures after the mass production done by our group during past several years in Basel University will be reported.

  18. Dynamical Analysis of a Pest Management Model with Saturated Growth Rate and State Dependent Impulsive Effects

    Directory of Open Access Journals (Sweden)

    Wencai Zhao

    2013-01-01

    Full Text Available A new pest management mathematical model with saturated growth is proposed. The integrated pest management (IPM strategy by introducing two state dependent pulses into the model is considered. Firstly, we analyze singular points of the model qualitatively and get the condition for focus point. Secondly, by using geometry theory of impulsive differential equation, the existence and stability of periodic solution of the system are discussed. Lastly, some examples and numerical simulations are given to illustrate our results.

  19. Local translational diffusion rates of membranous Na+,K(+)-ATPase measured by saturation transfer ESR spectroscopy.

    OpenAIRE

    Esmann, M.; Marsh, D.

    1992-01-01

    Diffusion-controlled Heisenberg spin exchange between spin-labeled Na+,K(+)-ATPase [ATP phosphohydrolase (Na+/K(+)-transporting), EC 3.6.1.37] proteins has been studied by saturation transfer ESR spectroscopy in reconstituted membranes. Na+,K(+)-ATPase from the salt gland of Squalus acanthias was solubilized in a polyoxyethylene ether detergent, octa(ethylene glycol) dodecyl monoether. Part of the solubilized enzyme was covalently spin-labeled with a nitroxide derivative of indanedione and re...

  20. Peripheral oxygen saturation, heart rate, and blood pressure during dental treatment of children with cyanotic congenital heart disease.

    Science.gov (United States)

    Dutra, Rosane Menezes Faria; Neves, Itamara Lucia Itagiba; Neves, Ricardo Simões; Atik, Edmar; Santos, Ubiratan de Paula

    2014-01-01

    In this observational study, we evaluated the peripheral oxygen saturation (SpO2), heart rate, and blood pressure of children with cyanotic congenital heart disease who were undergoing dental extraction. Forty-four patients between the ages of 6 and 12 years who underwent upper primary tooth extraction were included in the study. Of these, 20 patients were in the cyanotic congenital heart disease group and 24 were in the control group. Peripheral oxygen saturation, heart rate, and systolic blood pressure in the cyanotic congenital heart disease group varied quite significantly during the treatment protocol (pheart disease using a standardized protocol in decentralized offices without the support of a surgical center is safe.

  1. Statistical Analysis of Turbulence-Induced Fluctuations In In-Cloud Saturation Ratio and Rates of Cloud Droplet Growth

    Science.gov (United States)

    McGraw, R. L.; Luke, E. P.; Kollias, P.

    2014-12-01

    We develop methods that determine the influence of turbulence on the distribution of in-cloud water vapor saturation ratio and growth rates of cloud droplets. For this purpose, a moment-based cloud parcel model is used to translate Doppler cloud radar vertical velocity spectra and radiosonde measurements into a statistical distribution of in-cloud saturation ratio, S. Because cloud droplet growth/evaporation rates are proportional to S-1, the statistical analysis of fluctuations in S yields, among other quantities, direct information on the time correlation function of droplet growth rate. From this information a Green-Kubo relation is used to determine the diffusion coefficient for fluctuations along the coordinate of cloud droplet size, D, a key turbulence parameter used in the kinetic potential theory of drizzle formation. Measurements from the Azores, SGP, and TCAP sites are analyzed and compared. A significant finding is that the probability distribution function for fluctuations in S tends to be both highly symmetric about the equilibrium saturation ratio (S=1) and non-Gaussian. Indeed the distribution has much broader tails than the Gaussian and, for the cases we have studied, turns out to be in excellent agreement with the Voight lineshape.

  2. Development of Fast High-Resolution Muon Drift-Tube Detectors for High Counting Rates

    CERN Document Server

    INSPIRE-00287945; Dubbert, J.; Horvat, S.; Kortner, O.; Kroha, H.; Legger, F.; Richter, R.; Adomeit, S.; Biebel, O.; Engl, A.; Hertenberger, R.; Rauscher, F.; Zibell, A.

    2011-01-01

    Pressurized drift-tube chambers are e?cient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking e?ciency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a gas gain of 20000. The ATLAS MDT chambers are designed to cope with background counting rates due to neutrons and gamma-rays of up to about 300 kHz per tube which will be exceeded for LHC luminosities larger than the design value of 10-34 per square cm and second. Decreasing the drift-tube diameter to 15 mm while keeping the other parameters, including the gas gain, unchanged reduces the maximum drift time from about 700 ns to 200 ns and the drift-tube occupancy by a factor of 7. New drift-tube chambers for the endcap regions of the ATLAS muon spectrometer have been designed. A prototype chamber consisting of 12 times 8 l...

  3. Photon-counting X-ray imaging at kilohertz frame rates

    CERN Document Server

    Ponchut, Cyril; Rigal, J M; Papillon, E; Vallerga, J; LaMarra, D; Mikulec, B

    2007-01-01

    A kilohertz frame rate readout system for Medipix2 chips is being developed at European Synchrotron Radiation Facility (ESRF). This work was initiated with the aim of meeting the growing demand for fast and noise-free X-ray bidimensional detection particularly on synchrotron beamlines. Medipix2 is a photon-counting readout ASIC of 256×256 pixels with 55 μm pitch developed in the framework of the Medipix collaboration managed by CERN. The ESRF readout system is based on a custom interface board named Parallel Readout Image Acquisition for Medipix (PRIAM) a fast PCI interface and a Linux PC. The PRIAM board implementing fast FIFOs and a programmable gate array can read up to five Medipix2 circuits simultaneously in less than 0.3 ms using the 32-bit parallel readout port of Medipix2 and 100 MHz clock frequency. This paper describes the architecture of the PRIAM board, reports on the first test results, and mentions some of the targeted applications.

  4. [Species-dependence of the pattern of plant photosynthetic rate response to light intensity transition from saturating to limiting one].

    Science.gov (United States)

    Chen, Yue; Xu, Da-Quan

    2007-12-01

    By observing the photosynthetic responses of leaves to changes in light intensity and CO(2) concentration it was found that among the more than 50 plant species examined 32 species and 25 species showed respectively the V pattern and L pattern of the photosynthetic response to light intensity transition from saturating to limiting one (Figs.1 and 2 and Table 1). The pattern of photosynthetic response to light intensity transition is species-dependent but not leaf developmental stage-dependent (Fig.3). The species-dependence was not related to classification in taxonomy because the photosynthetic response might display the two different patterns (V and L) in plants of the same family, for example, rice and wheat (Gramineae), soybean and peanut (Leguminosae). It seemed to be related to the pathway of photosynthetic carbon assimilation because all of the C(4) plants examined (maize, green bristlegrass and thorny amaranth) displayed the L pattern. It might be related to light environment where the plants originated. The V pattern of photosynthetic response to light intensity transition was often observed in some plants grown in shade habitats, for example, sweet viburnum and Japan fatsia, while the L pattern was frequently observed in those plants grown in sunny habitats, for example, ginkgo and cotton. Furthermore, the ratio of electron transport rate to carboxylation rate in vivo measured at limiting light was far higher in the V pattern plants (mostly higher than 10) than in the L pattern plants (mostly lower than 5), but the ratio measured at saturating light had no significant difference between the two kinds of plants (Table 2). These results can be explained in part by that the V pattern plant species have larger light-harvesting complex (LHCII) and at saturating light the reversible dissociation of some LHCIIs from PSII reaction center complex occurs. The pattern of photosynthetic response to light intensity transition and the ratio of electron transport rate

  5. Analysis of geomagnetic storm variations and count-rate of cosmic ray muons recorded at the Brazilian southern space observatory

    Energy Technology Data Exchange (ETDEWEB)

    Frigo, Everton [University of Sao Paulo, USP, Institute of Astronomy, Geophysics and Atmospheric Sciences, IAG/USP, Department of Geophysics, Sao Paulo, SP (Brazil); Savian, Jairo Francisco [Space Science Laboratory of Santa Maria, LACESM/CT, Southern Regional Space Research Center, CRS/INPE, MCT, Santa Maria, RS (Brazil); Silva, Marlos Rockenbach da; Lago, Alisson dal; Trivedi, Nalin Babulal [National Institute for Space Research, INPE/MCT, Division of Space Geophysics, DGE, Sao Jose dos Campos, SP (Brazil); Schuch, Nelson Jorge, E-mail: efrigo@iag.usp.br, E-mail: savian@lacesm.ufsm.br, E-mail: njschuch@lacesm.ufsm.br, E-mail: marlos@dge.inpe.br, E-mail: dallago@dge.inpe.br, E-mail: trivedi@dge.inpe.br [Southern Regional Space Research Center, CRS/INPE, MCT, Santa Maria, RS (Brazil)

    2007-07-01

    An analysis of geomagnetic storm variations and the count rate of cosmic ray muons recorded at the Brazilian Southern Space Observatory -OES/CRS/INPE-MCT, in Sao Martinho da Serra, RS during the month of November 2004, is presented in this paper. The geomagnetic measurements are done by a three component low noise fluxgate magnetometer and the count rates of cosmic ray muons are recorded by a muon scintillator telescope - MST, both instruments installed at the Observatory. The fluxgate magnetometer measures variations in the three orthogonal components of Earth magnetic field, H (North-South), D (East-West) and Z (Vertical), with data sampling rate of 0.5 Hz. The muon scintillator telescope records hourly count rates. The arrival of a solar disturbance can be identified by observing the decrease in the muon count rate. The goal of this work is to describe the physical morphology and phenomenology observed during the geomagnetic storm of November 2004, using the H component of the geomagnetic field and vertical channel V of the multi-directional muon detector in South of Brazil. (author)

  6. Application of rate equations to ELDOR and saturation recovery experiments on 14N: 15N spin-label pairs

    Science.gov (United States)

    Yin, Jun-Jie; Hyde, James S.

    Rate equations describing the time dependence of population differences of the five allowed transitions in an 14N 15N spin-label pair problem are set up. Included in the formulation are the three Heisenberg exchange rate constants and different nitrogen nuclear spin-lattice relaxation rates, electron spin-lattice relaxation rates, and populations for the 14N and 15N moieties. Using matrix algebra, stationary and time-dependent solutions are obtained in a unified theoretical framework. The calculations apply to stationary and pulse electron-electron double resonance and to saturation-recovery ESR. Particular emphasis is placed on short pulse initial excitation, where the transverse relaxation processes are sufficiently slow that only the population difference of the irradiated transition departs significantly from Boltzmann equilibrium during the excitation.

  7. New Institutional Mechanism in China Facilitating the Global Sustainability--Environment to Be Counted in Officials' Performance Rating

    Institute of Scientific and Technical Information of China (English)

    Ren Jingming; Wang Rusong

    2004-01-01

    Having argued the importance of China's sustainable development in global sustainability, the authors review the achievements of China in sustainable development, especially its institutional construction. Environment to be counted in official's political performance rating system is thought of as a new institutional mechanism in China facilitating its sustainable development and then global sustainability. Then its significance is narrated and visions in future are envisioned. In the end, certain concrete suggestions for the rating system are given in a practical way.

  8. Photoassociation of ultracold LiRb* molecules: Observation of high efficiency and unitarity-limited rate saturation

    Science.gov (United States)

    Dutta, Sourav; Lorenz, John; Altaf, Adeel; Elliott, D. S.; Chen, Yong P.

    2014-02-01

    We report the production of ultracold heteronuclear Li7Rb85 molecules in excited electronic states by photoassociation (PA) of ultracold Li7 and Rb85 atoms. PA is performed in a dual-species Li7-Rb85 magneto-optical trap (MOT) and the PA resonances are detected using trap loss spectroscopy. We identify several strong PA resonances below the Li (2s 2S1/2) + Rb (5p 2P3/2) asymptote and experimentally determine the long range C6 dispersion coefficients. We find a molecule formation rate (PLiRb) of 3.5 × 107 s-1 and a PA rate coefficient (KPA) of 1.3 × 10-10 cm3/s, the highest among heteronuclear bi-alkali-metal molecules. At large PA laser intensity we observe the saturation of the PA rate coefficient (KPA) close to the theoretical value at the unitarity limit.

  9. Photoassociation of ultracold LiRb* molecules: observation of high efficiency and unitarity-limited rate saturation

    CERN Document Server

    Dutta, Sourav; Altaf, Adeel; Elliott, D S; Chen, Yong P

    2013-01-01

    We report the production of ultracold heteronuclear 7Li85Rb molecules in excited electronic states by photoassociation (PA) of ultracold 7Li and 85Rb atoms. PA is performed in a dual-species 7Li-85Rb magneto-optical trap (MOT) and the PA resonances are detected using trap loss spectroscopy. We identify several strong PA resonances below the Li (2s 2S1/2) + Rb (5p 2P3/2) asymptote and experimentally determine the long range C6 dispersion coefficients. We find a molecule formation rate (P_LiRb) of 3.5x10^7 s^-1 and a PA rate coefficient (K_PA) of 1.3x10^-10 cm^3/s, the highest among heteronuclear bi-alkali molecules. At large PA laser intensity, we observe the saturation of the PA rate coefficient (K_PA) close to the theoretical value at the unitarity limit.

  10. Detection of Anomalous Reactor Activity Using Antineutrino Count Rate Evolution Over the Course of a Reactor Cycle

    CERN Document Server

    Bulaevskaya, Vera

    2010-01-01

    This paper analyzes the sensitivity of antineutrino count rate measurements to changes in the fissile content of civil power reactors. Such measurements may be useful in IAEA reactor safeguards applications. We introduce a hypothesis testing procedure to identify statistically significant differences between the antineutrino count rate evolution of a standard 'baseline' fuel cycle and that of an anomalous cycle, in which plutonium is removed and replaced with an equivalent fissile worth of uranium. The test would allow an inspector to detect anomalous reactor activity, or to positively confirm that the reactor is operating in a manner consistent with its declared fuel inventory and power level. We show that with a reasonable choice of detector parameters, the test can detect replacement of 73 kg of plutonium in 90 days with 95% probability, while controlling the false positive rate at 5%. We show that some improvement on this level of sensitivity may be expected by various means, including use of the method i...

  11. Peripheral oxygen saturation, heart rate, and blood pressure during dental treatment of children with cyanotic congenital heart disease

    Directory of Open Access Journals (Sweden)

    Rosane Menezes Faria Dutra

    2014-01-01

    Full Text Available OBJECTIVES: In this observational study, we evaluated the peripheral oxygen saturation (SpO2, heart rate, and blood pressure of children with cyanotic congenital heart disease who were undergoing dental extraction. METHODS: Forty-four patients between the ages of 6 and 12 years who underwent upper primary tooth extraction were included in the study. Of these, 20 patients were in the cyanotic congenital heart disease group and 24 were in the control group. RESULTS: Peripheral oxygen saturation, heart rate, and systolic blood pressure in the cyanotic congenital heart disease group varied quite significantly during the treatment protocol (p<0.05, with values of 80.5% (±7.6 to 82.8% (±7.8, 95.3 beats per minute (bpm (±11.3 to 101.3 bpm (±9.8, and 93.6 mm Hg (±13,3 to 103.8 mm Hg (±12.7, respectively. The variations in the control group during the procedure were also significant. CONCLUSIONS: The changes observed during the study protocol, although statistically significant, were mild and lacked clinical relevance. The results indicate that dental treatment of children with cyanotic heart disease using a standardized protocol in decentralized offices without the support of a surgical center is safe.

  12. Saturation-recovery metabolic-exchange rate imaging with hyperpolarized [1-13C] pyruvate using spectral-spatial excitation.

    Science.gov (United States)

    Schulte, Rolf F; Sperl, Jonathan I; Weidl, Eliane; Menzel, Marion I; Janich, Martin A; Khegai, Oleksandr; Durst, Markus; Ardenkjaer-Larsen, Jan Henrik; Glaser, Steffen J; Haase, Axel; Schwaiger, Markus; Wiesinger, Florian

    2013-05-01

    Within the last decade hyperpolarized [1-13C] pyruvate chemical-shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time-resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using spectral-spatial excitation in combination with single-shot spiral data acquisition, the overall encoding is evenly distributed between excitation and signal reception, allowing the encoding of one full two-dimensional metabolite image per excitation. The signal-to-noise ratio can be flexibly adjusted and optimized using lower flip angles for the pyruvate substrate and larger ones for the downstream metabolites. Selectively adjusting the excitation of the down-stream metabolites to 90° leads to a so-called "saturation-recovery" scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using a simplified two-site exchange model. This novel contrast is an important step toward more quantitative metabolic imaging. Goal of this work was to derive, analyze, and implement this "saturation-recovery metabolic exchange rate imaging" and demonstrate its capabilities in four rats bearing subcutaneous tumors.

  13. Unintentional carbon monoxide poisoning hospitalization and emergency department counts and rates by county, year, and fire-relatedness among California residents,2000-2007

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of unintentional carbon monoxide poisoning (CO) inpatient hospitalizations and emergency...

  14. FROST: a low-noise high-rate photon counting ASIC for X-ray applications

    Energy Technology Data Exchange (ETDEWEB)

    Prest, M. E-mail: prest@ts.infn.it; Vallazza, E.; Chiavacci, M.; Mariani, R.; Motto, S.; Neri, M.; Scantamburlo, N.; Arfelli, F.; Conighi, A.; Longo, R.; Olivo, A.; Pani, S.; Poropat, P.; Rashevsky, A.; Rigon, L.; Tromba, G.; Castelli, E

    2001-04-01

    FRONTier RADiography is an R and D project to assess the feasibility of digital mammography with Synchrotron Radiation at the ELETTRA Light Source in Trieste. In order to reach an acceptable time duration of the exam, a fast- and low-noise photon counting ASIC has been developed in collaboration with Aurelia Microelettronica, called Frontrad ReadOut SysTem. It is a multichannel counting system, each channel being made of a low-noise charge-sensitive preamplifier optimized for X-ray energy range (10-100 keV), a CR-RC{sup 2} shaper, a discriminator and a 16-bit counter. In order to set the discriminator threshold, a set of a global 6-bit DAC and a local (per channel) 3-bit DAC has been implemented within the ASIC. We report on the measurements done with the 8-channel prototype chip and the comparison with the simulation results.

  15. Simplified quantification of labile proton concentration-weighted chemical exchange rate (k(ws) ) with RF saturation time dependent ratiometric analysis (QUESTRA): normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI.

    Science.gov (United States)

    Sun, Phillip Zhe

    2012-04-01

    Chemical exchange saturation transfer MRI is an emerging imaging technique capable of detecting dilute proteins/peptides and microenvironmental properties, with promising in vivo applications. However, chemical exchange saturation transfer MRI contrast is complex, varying not only with the labile proton concentration and exchange rate, but also with experimental conditions such as field strength and radiofrequency (RF) irradiation scheme. Furthermore, the optimal RF irradiation power depends on the exchange rate, which must be estimated in order to optimize the chemical exchange saturation transfer MRI experiments. Although methods including numerical fitting with modified Bloch-McConnell equations, quantification of exchange rate with RF saturation time and power (QUEST and QUESP), have been proposed to address this relationship, they require multiple-parameter non-linear fitting and accurate relaxation measurement. Our work extended the QUEST algorithm with ratiometric analysis (QUESTRA) that normalizes the magnetization transfer ratio at labile and reference frequencies, which effectively eliminates the confounding relaxation and RF spillover effects. Specifically, the QUESTRA contrast approaches its steady state mono-exponentially at a rate determined by the reverse exchange rate (k(ws) ), with little dependence on bulk water T(1) , T(2) , RF power and chemical shift. The proposed algorithm was confirmed numerically, and validated experimentally using a tissue-like phantom of serially titrated pH compartments.

  16. Loading Rate Effects on the One-Dimensional Compressibility of Four Partially Saturated Soils

    Science.gov (United States)

    1986-12-01

    OF FUNDING NUMBERS See reverse PROGRAM IPROJECT ITASK IWORK UNIT ELEMENT NO. 1NO. NO ACCESSION NO 1i rITLE (include SeCUrit ClaMfireme~n) Loading Rate...AOaa (2K - 4G ) Er (3-2) where: Aaa= change in axial stress K = bulk modulus of the soil G = shear modulus of the soil Since the change in axial...ratio of decrease in axial stress to radial stress, which he called the fractional error and expressed as: G-2 = (2K - 4G ) = (M - 2G) (3-3) Or 2Gst

  17. Analysis of a novel stochastic SIRS epidemic model with two different saturated incidence rates

    Science.gov (United States)

    Chang, Zhengbo; Meng, Xinzhu; Lu, Xiao

    2017-04-01

    This paper presents a stochastic SIRS epidemic model with two different nonlinear incidence rates and double epidemic asymmetrical hypothesis, and we devote to develop a mathematical method to obtain the threshold of the stochastic epidemic model. We firstly investigate the boundness and extinction of the stochastic system. Furthermore, we use Ito's formula, the comparison theorem and some new inequalities techniques of stochastic differential systems to discuss persistence in mean of two diseases on three cases. The results indicate that stochastic fluctuations can suppress the disease outbreak. Finally, numerical simulations about different noise disturbance coefficients are carried out to illustrate the obtained theoretical results.

  18. Gas bubbles in rats after heliox saturation and different decompression steps and rates.

    Science.gov (United States)

    Skogland, Steffen; Segadal, Kåre; Sundland, Harald; Hope, Arvid

    2002-06-01

    Effects of pressure reduction, decompression rate, and repeated exposure on venous gas bubble formation were determined in five groups (GI, GII, GIII, GIV, and GV) of conscious and freely moving rats in a heliox atmosphere. Bubbles were recorded with a Doppler ultrasound probe implanted around the inferior caval vein. Rats were held for 16 h at 0.4 MPa (GI), 0.5 MPa (GII and GIII), 1.7 MPa (GIVa), or 1.9 MPa (GIV and GV), followed by decompression to 0.1 MPa in GI to GIII and to 1.1 MPa in GIV and GV. A greater decompression step, but at the same rate (GII vs. GI and GIVb vs. GIVa), resulted in significantly more bubbles (P < 0.01). A twofold decompression step resulted in equal amount of bubbles when decompressing to 1.1 MPa compared with 0.1 MPa. The faster decompression in GII and GVa (10.0 kPa/s) resulted in significantly more bubbles (P < 0.01) compared with GIII and GVb (2.2 kPa/s). No significant difference was observed in cumulative bubble score when comparing first and second exposure. With the present animal model, different decompression regimes may be evaluated.

  19. Estimation of Saturation Flow Rate and Start-Up Lost Time for Signal Timing Based on Headway Distribution

    Directory of Open Access Journals (Sweden)

    Yi Zhao

    2015-01-01

    Full Text Available This study aimed to calibrate saturation flow rate (SFR and start-up lost time (SLT when developing signal timing. In current commonly used methods, SFR for one given lane is usually calibrated from many subjective adjustment factors and a fixed result. SLT is calculated based on the fixed SFR, which prevents local applications in China. Considering the importance of traffic behavior (headway in determining SFR and SLT, this study started from headway distribution and attempted to specify the relationships between headway and vehicle position directly. A common intersection in Nanjing, China, was selected to implement field study and data from 920 queues was collected. Headway distribution was explored and the 78th percentile of headway at each position was selected to build model. Based on the developed relationships, SFR and SLT were calibrated. The results showed that SFR and SLT were correlated with queue length. Moreover, the results showed that it was difficult to reach saturated state even with a long queue length. This paper provides a new perspective on calibrating important parameters in signal timing, which will be useful for traffic agencies to complete signal timing by making the process simpler.

  20. The study of error for analysis in dynamic image from the error of count rates in Nal (Tl) scintillation camera

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joo Young; Kang, Chun Goo; Kim, Jung Yul; Oh, Ki Baek; Kim, Jae Sam [Dept. of Nuclear Medicine, Severance Hospital, Yonsei University, Seoul (Korea, Republic of); Park, Hoon Hee [Dept. of Radiological Technology, Shingu college, Sungnam (Korea, Republic of)

    2013-12-15

    This study is aimed to evaluate the effect of T{sub 1/2} upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with '9{sup 9m}TcO{sub 4}- of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in χ{sup 2} test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of T{sub 1/2} error from change of gradient with -0.25% to +0.25%, if T{sub 1/2} is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see T{sub 1/2} error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation

  1. CLARO: an ASIC for high rate single photon counting with multi-anode photomultipliers

    Science.gov (United States)

    Baszczyk, M.; Carniti, P.; Cassina, L.; Cotta Ramusino, A.; Dorosz, P.; Fiorini, M.; Gotti, C.; Kucewicz, W.; Malaguti, R.; Pessina, G.

    2017-08-01

    The CLARO is a radiation-hard 8-channel ASIC designed for single photon counting with multi-anode photomultiplier tubes. Each channel outputs a digital pulse when the input signal from the photomultiplier crosses a configurable threshold. The fast return to baseline, typically within 25 ns, and below 50 ns in all conditions, allows to count up to 107 hits/s on each channel, with a power consumption of about 1 mW per channel. The ASIC presented here is a much improved version of the first 4-channel prototype. The threshold can be precisely set in a wide range, between 30 ke- (5 fC) and 16 Me- (2.6 pC). The noise of the amplifier with a 10 pF input capacitance is 3.5 ke- (0.6 fC) RMS. All settings are stored in a 128-bit configuration and status register, protected against soft errors with triple modular redundancy. The paper describes the design of the ASIC at transistor-level, and demonstrates its performance on the test bench.

  2. High precipitation rate in a Middle Triassic carbonate platform: Implications on the relationship between seawater saturation state and carbonate production

    Science.gov (United States)

    Franceschi, Marco; Preto, Nereo; Marangon, Alessandro; Gattolin, Giovanni; Meda, Marco

    2016-06-01

    Three-dimensional geological modeling of the Middle Triassic Latemar carbonate platform is coupled with facies modal analysis to estimate its carbonate precipitation rate (G). The 3D model, strongly constrained by field data, encompasses a specific stratigraphic interval of the platform, bounded by two isochronous surfaces. Modal analysis of thin sections allows estimating the proportion of syndepositional vs postdepositional carbonate in the facies associations of the platform. This, together with the 3D facies distribution in the model that takes into account lateral and vertical facies variability, permits to calculate the volumes of syndepositional carbonate preserved at Latemar between the two considered isochrones. Given the peculiar characteristics of the platform, that does not show evidences of strong dissolution processes or large carbonate mass loss through export in the nearby basins, results can be used to estimate the average precipitation rate of the platform in the considered time interval. This estimate allows discussion in relation to models of ocean water saturation state (Ω) with respect to carbonates in the geological past, and comparison to the calculated precipitation rates of modern tropical coral reef ecosystems at global and reef scale. A high G value is found at Latemar and represents the first empirical confirmation that, in the Triassic, extremes in Ω may have triggered high carbonate precipitation in shallow water settings; moreover, comparison to modern reefs points to a possible common relationship that may link seawater Ω and precipitation rate in carbonate platform ecosystems through geological time.

  3. The effects of perceiving color in living environment on QEEG, oxygen saturation, pulse rate, and emotion regulation in humans.

    Science.gov (United States)

    Sroykham, Watchara; Wongsathikun, J; Wongsawat, Y

    2014-01-01

    Light and color have been shown to have substantial physical, psychological and sociological effects on humans. Hence, an investigation on the effect of changes in light and color to the biological signals is a challenging problem. Five participants were measured the oxygen saturation (SpO2), pulse rate, and quantitative electroencephalogram (QEEG) in six colors (white, blue, green, yellow, red and black) of living environment for 5 minutes per color. Then all participants were asked to answer the emotional questionnaire of BRUMS and color performance for each color environment. The results showed brain activity of high beta wave (25-30 Hz) that associated with alertness, agitation, mental activity, and general activation of mind and body functions (at frontal lobes and temporal lobes) in red and yellow colored rooms were higher than blue, green, white and black colored rooms, respectively. It also had the relationship with the psychological effect (BRUMS). The amplitude asymmetry of beta wave (12-25 Hz) was highly attenuated in warm color (red and yellow colored rooms), moderately attenuated in cool color (green and blue colored room) and little attenuated in white and black colored rooms. The BRUMS showed that red and yellow yielded significant effect on anger (F = 4.966, p = 0.002) and confusion (F=3.853, p=0.008). Red and green color yielded high effect on vigor. Green color did not affect the depression. Blue color yielded moderate effect on confusion, tension and fatigue. White and black colors yielded low effect on any mood, but black color had no effect on vigor. In addition, we cannot observe any significant changes of pulse rate and blood oxygen saturation in each color. The results can possibly be used as the recommendation to design the room for either normal people or patients.

  4. Correction of dead-time and pile-up in a detector array for constant and rapidly varying counting rates

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, C. [Centro de Investigaciones Medioambientales, Energéticas y Tecnológicas (CIEMAT), Madrid (Spain); Departamento de Física Atómica, Molecular y Nuclear, Universidad de Sevilla (Spain); Cano-Ott, D.; Mendoza, E. [Centro de Investigaciones Medioambientales, Energéticas y Tecnológicas (CIEMAT), Madrid (Spain); Wright, T. [University of Manchester, Manchester (United Kingdom)

    2015-03-21

    The effect of dead-time and pile-up in counting experiments may become a significant source of uncertainty if not properly taken into account. Although analytical solutions to this problem have been proposed for simple set-ups with one or two detectors, these are limited when it comes to arrays where time correlation between the detector modules is used, and also in situations of variable counting rates. In this paper we describe the dead-time and pile-up corrections applied to the n-TOF Total Absorption Calorimeter (TAC), a 4π γ-ray detector made of 40 BaF{sub 2} modules operating at the CERN n-TOF facility. Our method is based on the simulation of the complete signal detection and event reconstruction processes and can be applied as well in the case of rapidly varying counting rates. The method is discussed in detail and then we present its successful application to the particular case of the measurement of {sup 238}U(n, γ) reactions with the TAC detector.

  5. HEPS-BPIX, a single photon counting pixel detector with a high frame rate for the HEPS project

    Science.gov (United States)

    Wei, Wei; Zhang, Jie; Ning, Zhe; Lu, Yunpeng; Fan, Lei; Li, Huaishen; Jiang, Xiaoshan; Lan, Allan K.; Ouyang, Qun; Wang, Zheng; Zhu, Kejun; Chen, Yuanbo; Liu, Peng

    2016-11-01

    China's next generation light source, named the High Energy Photon Source (HEPS), is currently under construction. HEPS-BPIX (HEPS-Beijing PIXel) is a dedicated pixel readout chip that operates in single photon counting mode for X-ray applications in HEPS. Designed using CMOS 0.13 μm technology, the chip contains a matrix of 104×72 pixels. Each pixel measures 150 μm×150 μm and has a counting depth of 20 bits. A bump-bonded prototyping detector module with a 300-μm thick silicon sensor was tested in the beamline of Beijing Synchrotron Radiation Facility. A fast stream of X-ray images was demonstrated, and a frame rate of 1.2 kHz was proven, with a negligible dead time. The test results showed an equivalent noise charge of 115 e- rms after bump bonding and a threshold dispersion of 55 e- rms after calibration.

  6. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST).

    Science.gov (United States)

    Friedman, Joshua I; Xia, Ding; Regatte, Ravinder R; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates⩾30s(-1)) while simultaneously eliminating signals originating from slower (∼5s(-1)) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast.

  7. Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

    Energy Technology Data Exchange (ETDEWEB)

    Zickefoose, J.; Kulkarni, T.; Martinson, T.; Phillips, K.; Voelker, M. [Canberra Industries Inc. (United States)

    2015-07-01

    The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube

  8. CONSUMPTION OF SATURATED ANIMAL FATS IN THE DIET OF HUMANS MAY DECREASE THE RATE OF HEART DISEASE IN THE FUTURE

    OpenAIRE

    Soroush Niknamian; Mehrandokht Nekavand

    2017-01-01

    Fats, as part of the human dietary regime are a concentrated source of energy. Animals contain saturated and plants contain unsaturated type of fatty acids. In this prospective research, the role of animal saturated fatty acids is highlighted and is proven to be a rational dietary source for the human diet. Saturated fats consumption is a wise choice in order to reduce the coronary heart disease risk, although it is believed in an opposite way. Researching through the healthiest tribes and kn...

  9. Low-Noise Free-Running High-Rate Photon-Counting for Space Communication and Ranging

    Science.gov (United States)

    Lu, Wei; Krainak, Michael A.; Yang, Guan; Sun, Xiaoli; Merritt, Scott

    2016-01-01

    We present performance data for low-noise free-running high-rate photon counting method for space optical communication and ranging. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We successfully measured real-time communication performance using both the 2 detected-photon threshold and logic AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects without using other method of Time Gating The HgCdTe APD array routinely demonstrated very high photon detection efficiencies (50) at near infrared wavelength. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output. NASA GSFC has tested both detectors for their potential application for space communications and ranging. We developed and compare their performances using both the 2 detected photon threshold and coincidence methods.

  10. A Count for Quality: Child Care Center Directors on Rating and Improvement Systems

    Science.gov (United States)

    Schulman, Karen; Matthews, Hannah; Blank, Helen; Ewen, Danielle

    2012-01-01

    Quality Rating and Improvement Systems (QRIS)--a strategy to improve families' access to high-quality child care--assess the quality of child care programs, offer incentives and assistance to programs to improve their ratings, and give information to parents about the quality of child care. These systems are operating in a growing number of…

  11. Acute resistance exercise with blood flow restriction effects on heart rate, double product, oxygen saturation and perceived exertion.

    Science.gov (United States)

    Neto, Gabriel R; Sousa, Maria S C; Costa e Silva, Gabriel V; Gil, Ana L S; Salles, Belmiro F; Novaes, Jefferson S

    2016-01-01

    The aim of this study was to compare the acute effect of resistance exercise (RE) with and without blood flow restriction (BFR) on heart rate (HR), double product (DP), oxygen saturation (SpO2 ) and rating of perceived exertion (RPE). Twenty-four men (21·79 ± 3·21 years) performed three experimental protocols in a random order (crossover): (i) high-intensity RE at 80% of 1RM (HI), (ii) low-intensity RE at 20% of 1RM (LI) and (iii) low-intensity RE at 20% of 1RM combined with partial blood flow restriction (LI+BFR). HR, blood pressure, SpO2 and RPE were assessed. The data were analysed using repeated measures analysis of variance and the Wilcoxon test for RPE. The results indicated that all protocols significantly increased HR, both immediately postexercise and during the subsequent 60 min (Pexercise and increase HR and DP while maintaining a perception of greater exertion on the lower limbs. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  12. Monitoring cerebral oxygen saturation during cardiopulmonary bypass using near-infrared spectroscopy: the relationships with body temperature and perfusion rate

    Science.gov (United States)

    Teng, Yichao; Ding, HaiShu; Gong, Qingcheng; Jia, Zaishen; Huang, Lan

    2006-03-01

    During cardiopulmonary bypass (CPB) because of weak arterial pulsation, near-IR spectroscopy (NIRS) is almost the only available method to monitor cerebral oxygenation noninvasively. Our group develops a NIRS oximeter to monitor regional cerebral oxygenation especially its oxygen saturation (rScO2). To achieve optimal coupling between the sensor and human brain, the distances between the light source and the detectors on it are properly chosen. The oximeter is calibrated by blood gas analysis, and the results indicate that its algorithm is little influenced by either background absorption or overlying tissue. We used it to measure the rScO2 of 15 patients during CPB. It is shown that rScO2 is negatively correlated with body temperature and positively with perfusion rate. There are two critical stages during CPB when rScO2 might be relatively low: one is the low-perfusion-rate stage, the other is the early rewarming stage. During cooling, the changes of total hemoglobin concentration (CtHb) compared with its original value is also monitored. It is shown that CtHb decreases to a small extent, which may mainly reflect cerebral vasoconstriction induced by cooling. All these results indicate that NIRS can be used to monitor cerebral oxygenation to protect cerebral tissue during CPB.

  13. Aspartic acid racemization rate in narwhal (Monodon monoceros) eye lens nuclei estimated by counting of growth layers in tusks

    DEFF Research Database (Denmark)

    Garde, Eva; Heide-Jørgensen, Mads Peter; Ditlevsen, Susanne

    2012-01-01

    Ages of marine mammals have traditionally been estimated by counting dentinal growth layers in teeth. However, this method is difficult to use on narwhals (Monodon monoceros) because of their special tooth structures. Alternative methods are therefore needed. The aspartic acid racemization (AAR......) technique has been used in age estimation studies of cetaceans, including narwhals. The purpose of this study was to estimate a species-specific racemization rate for narwhals by regressing aspartic acid D/L ratios in eye lens nuclei against growth layer groups in tusks (n=9). Two racemization rates were...... rate and (D/L)0 value be used in future AAR age estimation studies of narwhals, but also recommend the collection of tusks and eyes of narwhals for further improving the (D/L)0 and 2kAsp estimates obtained in this study....

  14. Genetic Modifiers of White Blood Cell Count, Albuminuria and Glomerular Filtration Rate in Children with Sickle Cell Anemia

    Science.gov (United States)

    Flanagan, Jonathan M.; Alvarez, Ofelia A.; Nelson, Stephen C.; Aygun, Banu; Nottage, Kerri A.; George, Alex; Roberts, Carla W.; Piccone, Connie M.; Howard, Thad A.; Davis, Barry R.; Ware, Russell E.

    2016-01-01

    Discovery and validation of genetic variants that influence disease severity in children with sickle cell anemia (SCA) could lead to early identification of high-risk patients, better screening strategies, and intervention with targeted and preventive therapy. We hypothesized that newly identified genetic risk factors for the general African American population could also impact laboratory biomarkers known to contribute to the clinical disease expression of SCA, including variants influencing the white blood cell count and the development of albuminuria and abnormal glomerular filtration rate. We first investigated candidate genetic polymorphisms in well-characterized SCA pediatric cohorts from three prospective NHLBI-supported clinical trials: HUSTLE, SWiTCH, and TWiTCH. We also performed whole exome sequencing to identify novel genetic variants, using both a discovery and a validation cohort. Among candidate genes, DARC rs2814778 polymorphism regulating Duffy antigen expression had a clear influence with significantly increased WBC and neutrophil counts, but did not affect the maximum tolerated dose of hydroxyurea therapy. The APOL1 G1 polymorphism, an identified risk factor for non-diabetic renal disease, was associated with albuminuria. Whole exome sequencing discovered several novel variants that maintained significance in the validation cohorts, including ZFHX4 polymorphisms affecting both the leukocyte and neutrophil counts, as well as AGGF1, CYP4B1, CUBN, TOR2A, PKD1L2, and CD163 variants affecting the glomerular filtration rate. The identification of robust, reliable, and reproducible genetic markers for disease severity in SCA remains elusive, but new genetic variants provide avenues for further validation and investigation. PMID:27711207

  15. Saturated Domino Coverings

    CERN Document Server

    Buchanan, Andrew; Ryba, Alex

    2011-01-01

    A domino covering of a board is saturated if no domino is redundant. We introduce the concept of a fragment tiling and show that a minimal fragment tiling always corresponds to a maximal saturated domino covering. The size of a minimal fragment tiling is the domination number of the board. We define a class of regular boards and show that for these boards the domination number gives the size of a minimal X-pentomino covering. Natural sequences that count maximal saturated domino coverings of square and rectangular boards are obtained. These include the new sequences A193764, A193765, A193766, A193767, and A193768 of OEIS.

  16. 10  GHz pulse repetition rate Er:Yb:glass laser modelocked with quantum dot semiconductor saturable absorber mirror.

    Science.gov (United States)

    Resan, B; Kurmulis, S; Zhang, Z Y; Oehler, A E H; Markovic, V; Mangold, M; Südmeyer, T; Keller, U; Hogg, R A; Weingarten, K J

    2016-05-10

    Semiconductor saturable absorber mirror (SESAM) modelocked high pulse repetition rate (≥10  GHz) diode-pumped solid-state lasers are proven as an enabling technology for high data rate coherent communication systems owing to their low noise and high pulse-to-pulse optical phase-coherence. Compared to quantum well, quantum dot (QD)-based SESAMs offer potential advantages to such laser systems in terms of reduced saturation fluence, broader bandwidth, and wavelength flexibility. Here, we describe the first 10 GHz pulse repetition rate QD-SESAM modelocked laser at 1.55 μm, exhibiting 2 ps pulse width from an Er-doped glass oscillator (ERGO). The 10 GHz ERGO laser is modelocked with InAs/GaAs QD-SESAM with saturation fluence as low as 9  μJ/cm2.

  17. Longitudinal investigation of carriage rates, counts, and genotypes of toxigenic Clostridium difficile in early infancy

    NARCIS (Netherlands)

    Kubota, Hiroyuki; Makino, Hiroshi; Gawad, Agata; Kushiro, Akira; Ishikawa, Eiji; Sakai, Takafumi; Akiyama, Takuya; Matsuda, Kazunori; Martin, Rocio; Knol, Jan; Oishi, Kenji

    2016-01-01

    Asymptomatic infant carriers of toxigenic Clostridium difficile are suggested to play a role in the transmission of C. difficile infection (CDI) in adults. However, the mode of C. difficile carriage in infants remains to be fully elucidated. We investigated longitudinal changes in carriage rates,

  18. Longitudinal investigation of carriage rates, counts, and genotypes of toxigenic Clostridium difficile in early infancy

    NARCIS (Netherlands)

    Kubota, Hiroyuki; Makino, Hiroshi; Gawad, Agata; Kushiro, Akira; Ishikawa, Eiji; Sakai, Takafumi; Akiyama, Takuya; Matsuda, Kazunori; Martin, Rocio; Knol, Jan; Oishi, Kenji

    2016-01-01

    Asymptomatic infant carriers of toxigenic Clostridium difficile are suggested to play a role in the transmission of C. difficile infection (CDI) in adults. However, the mode of C. difficile carriage in infants remains to be fully elucidated. We investigated longitudinal changes in carriage rates,

  19. Improving the assessment of activity in samples with non-uniform distribution using the sum peak count rate.

    Science.gov (United States)

    Suvaila, Rares; Osvath, Iolanda; Sima, Octavian

    2013-11-01

    In this work a method for the evaluation of the activity when a point source containing (60)Co is located in an unknown position within a sample is developed. The method can be applied if the count rate in the 2,505 keV sum peak has an acceptable uncertainty. It is based on the correlation between the apparent efficiency for the 1,173 keV peak and the ratio of the count rate in the sum peak of 2,505 keV and in the 1,332 keV peak. The correlation was observed in the measurements of a (60)Co point source located in various positions in a soil sample. The measurements were done with a 47% efficiency n-type HPGe detector. The correlation is also observed in the measurements and simulations done with a Compton-suppressed spectrometer having a 100% n-type HPGe detector. The results obtained with the proposed method are less affected by the uncertainty of the position of the point source than the results obtained using the standard methods of activity evaluation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Dependence of the neutron monitor count rate and time delay distribution on the rigidity spectrum of primary cosmic rays

    Science.gov (United States)

    Mangeard, P.-S.; Ruffolo, D.; Sáiz, A.; Nuntiyakul, W.; Bieber, J. W.; Clem, J.; Evenson, P.; Pyle, R.; Duldig, M. L.; Humble, J. E.

    2016-12-01

    Neutron monitors are the premier instruments for precisely tracking time variations in the Galactic cosmic ray flux at GeV-range energies above the geomagnetic cutoff at the location of measurement. Recently, a new capability has been developed to record and analyze the neutron time delay distribution (related to neutron multiplicity) to infer variations in the cosmic ray spectrum as well. In particular, from time delay histograms we can determine the leader fraction L, defined as the fraction of neutrons that did not follow a previous neutron detection in the same tube from the same atmospheric secondary particle. Using data taken during 2000-2007 by a shipborne neutron monitor latitude survey, we observe a strong dependence of the count rate and L on the geomagnetic cutoff. We have modeled this dependence using Monte Carlo simulations of cosmic ray interactions in the atmosphere and in the neutron monitor. We present new yield functions for the count rate of a neutron monitor at sea level. The simulation results show a variation of L with geomagnetic cutoff as observed by the latitude survey, confirming that these changes in L can be attributed to changes in the cosmic ray spectrum arriving at Earth's atmosphere. We also observe a variation in L with time at a fixed cutoff, which reflects the evolution of the cosmic ray spectrum with the sunspot cycle, known as solar modulation.

  1. Skin conductance as pain indicator in newborns: a comparison study with heart rate, oxygen saturation and pain behavioral scales

    Directory of Open Access Journals (Sweden)

    Jose Alfredo Lacerda de Jesus

    2013-09-01

    Full Text Available Introduction Heart rate (HR, oxygen saturation (OS and skin conductance activity (SCA are physiological markers of acute pain. Neonatal Facial Coding System (NFCS, Neonatal Infant Pain Scale (NIPS and modified COMFORT are validated pain behavioral scales. Objective It was to compare whether the scores of these measures fit the psychophysical parameters for a pain marker (intensity, reactivity, direction, regulation and slope. Method Observational prospective study including 41 newborns, in which it were compared the maximum HR, the minimum OS, the SCA variables number of waves per second (NWps and relative area under the curve of waves (AUC, and the scores of behavioral pain scales in the periods before, during and after heel prick. Results The parameters intensity and regulation were significant for the NWps (p0.05. The slope was significant for the minimum OS and NIPS and modified COMFORT scales (p<0.05. Conclusion The responses of SCA, HR, OS and behavioral pain scales are similarly in acute painful events. They fit the psychophysical parameters of a pain marker and serve as measures for pain diagnostic.

  2. Radial variations in cation exchange capacity and base saturation rate in the wood of pedunculate oak and European beech

    Energy Technology Data Exchange (ETDEWEB)

    Herbauts, J.; Penninckx, V.; Gruber, W.; Meerts, P. [Universite Libre de Bruxelles, Laboratoire de genetique et d' ecologie vegetales, Brussels (Belgium)

    2002-10-01

    Visual observation of pedunculate oak trees and European beech trees in a mixed forest stand in the Belgian Ardennes revealed decreasing cation concentration profiles in wood. In order to determine whether these profiles are attributable to endogenous factors or to decreased availability of cations in the soil, radial profiles of water-soluble, exchangeable and total cations were investigated. Cation exchange capacity of wood was also determined. Results showed wood cation exchange capacity to decrease from pith to bark in European beech and from pith to outer heartwood in pedunculate oak. Decreasing profiles of exchangeable calcium and magnesium in peduncular oak and exchangeable calcium in European beech were found to be strongly constrained by cation exchange capacity, and thus not related to environmental change. Base cation saturation rate showed no consistent radial change in either species. It was concluded that the results did not provide convincing evidence to attribute the decrease in divalent cation concentration in pedunculate oak and European beech in this location to be due to atmospheric pollution. 42 refs., 1 tab., 4 figs.

  3. 2Kx2K resolution element photon counting MCP sensor with >200 kHz event rate capability

    CERN Document Server

    Vallerga, J V

    2000-01-01

    Siegmund Scientific undertook a NASA Small Business Innovative Research (SBIR) contract to develop a versatile, high-performance photon (or particle) counting detector combining recent technical advances in all aspects of Microchannel Plate (MCP) detector development in a low cost, commercially viable package that can support a variety of applications. The detector concept consists of a set of MCPs whose output electron pulses are read out with a crossed delay line (XDL) anode and associated high-speed event encoding electronics. The delay line anode allows high-resolution photon event centroiding at very high event rates and can be scaled to large formats (>40 mm) while maintaining good linearity and high temporal stability. The optimal sensitivity wavelength range is determined by the choice of opaque photocathodes. Specific achievements included: spatial resolution of 200 000 events s sup - sup 1; local rates of >100 events s sup - sup 1 per resolution element; event timing of <1 ns; and low background ...

  4. Free-running InGaAs single photon detector with 1 cps dark count rate at 10% efficiency

    CERN Document Server

    Korzh, Boris; Lunghi, Tommaso; Gisin, Nicolas; Zbinden, Hugo

    2013-01-01

    We present a free-running single photon detector for telecom wavelengths based on a negative feedback avalanche photodiode (NFAD). A dark count rate as low as 1 cps was obtained at a detection efficiency of 10%, with an afterpulse probability of 2.2% for 20 {\\mu}s of deadtime. This was achieved by using an active hold-off circuit and cooling the NFAD with a free-piston stirling cooler down to temperatures of -110${^o}$C. We integrated two detectors into a practical, 625 MHz clocked quantum key distribution system. Stable, real-time key distribution in presence of 30 dB channel loss was possible, yielding a secret key rate of 350 bps.

  5. Local thermal pressurization triggered by flash heating causes dramatic weakening in water-saturated gouges at subseismic slip rates

    Science.gov (United States)

    Yao, Lu; Ma, Shengli; Shimamoto, Toshihiko; Togo, Tetsuhiro; Chen, Jianye; Kitajima, Hiroko; Wang, Yu; He, Honglin

    2017-04-01

    High-velocity friction studies on water-saturated gouges in recent years have demonstrated that the wet gouges subjected to high-velocity shear tend to have smaller peak and steady-state friction, much shorter slip-weakening distance and lower fracture energy, as compared to the air-dry gouges. Thermal pressurization, compaction-induced pressurization, and flash heating were previously recognized to be the important weakening mechanisms in causing these behaviors. However, in spite of theoretical expectation, there is few evidence to support the occurrence of flash heating in wet gouges, mainly due to the superimposition of multiple weakening mechanisms especially for thermal pressurization. We devised friction experiments to study the role of flash heating in dynamic weakening of water-saturated gouges. In each experiment, we used a pressure vessel to impose a pore pressure of 2.0 MPa on the gouge layer sandwiched between porous ceramics blocks, and applied a long preslide of 1.0 m in displacement before starting the experiment at the target slip rate. By doing so we could (1) suppress rapid thermal pressurization in the bulk gouge layer by means of the designed drained condition and elevated temperature of phase transition of pore water; (2) suppress or even eliminate the pressurization effects due to compaction especially at the very beginning of the experiment. The experiments were performed on a granular gouge (mainly quartz, plagioclase, calcite and illite) and a clay-rich gouge (illite and chlorite ˜58 wt%), which were both collected from the Qingchuan fault of the Longmenshan fault system. For the granular gouge, the steady-state friction coefficients (μss) are 0.39-0.42 at slip rates (V ) of 100 μm/s-10 mm/s; however, at V ≥40 mm/s, the friction coefficients (μ) decrease suddenly at the onset of the slip. For instance, μ reduces by 0.29 within displacement of 0.05-0.08m at V =100 mm/s. For the clay-rich gouge, μss increases from 0.24 to 0.34 as V

  6. Optimization of statistical methods for HpGe gamma-ray spectrometer used in wide count rate ranges

    Science.gov (United States)

    Gervino, G.; Mana, G.; Palmisano, C.

    2016-07-01

    The need to perform γ-ray measurements with HpGe detectors is a common technique in many fields such as nuclear physics, radiochemistry, nuclear medicine and neutron activation analysis. The use of HpGe detectors is chosen in situations where isotope identification is needed because of their excellent resolution. Our challenge is to obtain the "best" spectroscopy data possible in every measurement situation. "Best" is a combination of statistical (number of counts) and spectral quality (peak, width and position) over a wide range of counting rates. In this framework, we applied Bayesian methods and the Ellipsoidal Nested Sampling (a multidimensional integration technique) to study the most likely distribution for the shape of HpGe spectra. In treating these experiments, the prior information suggests to model the likelihood function with a product of Poisson distributions. We present the efforts that have been done in order to optimize the statistical methods to HpGe detector outputs with the aim to evaluate to a better order of precision the detector efficiency, the absolute measured activity and the spectra background. Reaching a more precise knowledge of statistical and systematic uncertainties for the measured physical observables is the final goal of this research project.

  7. Simplified quantification of labile proton concentration-weighted chemical exchange rate (kws) with RF saturation time dependent ratiometric analysis (QUESTRA) - Normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI

    Science.gov (United States)

    Sun, Phillip Zhe

    2012-01-01

    Chemical exchange saturation transfer (CEST) MRI is an emerging imaging technique capable of detecting dilute proteins/peptides and microenvironmental properties, with promising in vivo applications. However, CEST MRI contrast is complex, varying not only with the labile proton concentration and exchange rate, but also with experimental conditions such as field strength and RF irradiation scheme. Furthermore, the optimal RF irradiation power depends on the exchange rate, which must be estimated in order to optimize the CEST MRI experiments. Although methods including numerical fitting with modified Bloch-McConnell equations, quantification of exchange rate with RF saturation time and power (QUEST and QUESP), have been proposed to address this relationship, they require multiple-parameter non-linear fitting and accurate relaxation measurement. Our work here extended the QUEST algorithm with ratiometric analysis (QUESTRA) that normalizes the magnetization transfer ratio (MTR) at labile and reference frequencies, which effectively eliminates the confounding relaxation and RF spillover effects. Specifically, the QUESTRA contrast approaches its steady state mono-exponentially at a rate determined by the reverse exchange rate (kws), with little dependence on bulk water T1, T2, RF power and chemical shift. The proposed algorithm was confirmed numerically, and validated experimentally using a tissue-like phantom of serially titrated pH compartments. PMID:21842497

  8. Leukocyte Count and Erythrocyte Sedimentation Rate as Diagnostic Factors in Febrile Convulsion

    Directory of Open Access Journals (Sweden)

    Ali Akbar Rahbarimanesh

    2011-07-01

    Full Text Available "nFebrile convulsion (FC is the most common seizure disorder in childhood. white blood cell (WBC and erythrocyte sedimentation rate (ESR are commonly measured in FC. Trauma, vomiting and bleeding can also lead to WBC and ESR so the blood tests must carefully be interpreted by the clinician. In this cross sectional study 410 children(163 with FC, aged 6 months to 5 years, admitted to Bahrami Children hospital in the first 48 hours of their febrile disease, either with or without seizure, were evaluated over an 18 months period. Age, sex, temperature; history of vomiting, bleeding or trauma; WBC, ESR and hemoglobin were recorded in all children. There was a significant increase of WBC (P<0.001 in children with FC so we can deduct that leukocytosis encountered in children with FC can be due to convulsion in itself. There was no significant difference regarding ESR (P=0.113 between the two groups. In fact, elevated ESR is a result of underlying pathology. In stable patients who don't have any indication of lumbar puncture, there's no need to assess WBC and ESR as an indicator of underlying infection. If the patient is transferred to pediatric ward and still there's no reason to suspect a bacterial infection, there is no need for WBC test.

  9. [Study of blood oxygen saturation, heart rate changes and plateau reaction of the Antarctic Kunlun station investigation team in different plateau environments].

    Science.gov (United States)

    Zhao, Shun-yun; Wu, Xin-min; Guo, Ya-min; Zhang, Shu-shun; An, Yan-ming; Li, Bing; Wang, Hao

    2013-06-11

    To explore the blood oxygen saturation and heart rate changes of the Antarctic explorers. During August 2010 to April 2011, the changes in blood oxygen saturation, heart rate and plateau reaction of 16 Antarctic expedition team in different plateau environments (Tibetan plateau versus Antarctic plateau) were monitored with the noninvasive pulse oximeter MD300-C. The extent of acute mountain sickness was determined according to the Lake Louise Consensus acute mountain reaction symptom scores and judgment method. The changes of blood oxygen saturation, heart rate at different altitudes of 110, 3650, 4300 m (96.8% ± 1.2%,89.1% ± 1.2%, 86.1% ± 2.0%, (75.0 ± 5.4) times/min, (104.0 ± 4.3) times/min, (113.0 ± 5.2) times/min,F = 214.155, 240.088,both P blood oxygen saturation, heart rate at different altitudes of 2000, 2500, 3000, 3500 and 4087 m(91.9% ± 1.3%,90.5% ± 1.3%,87.6% ± 1.4%,85.0% ± 1.8%,81.5% ± 2.2%, (85.9 ± 3.2) times/min, (90.6 ± 2.8) times/min, (97.8 ± 4.1) times/min, (102.0 ± 3.4) times/min, (106.3 ± 3.9) times/min, F = 105.418, 90.174, both P blood oxygen saturation and heart rate were both correlated with the risk of altitude sickness (r = -0.446 and 0.565, both P heart rate of the Antarctic explorers. And with the increases of altitude, the risk of altitude sickness gradually increases.

  10. Counting rate measurements for lifetime experiments using the RDDS method with the new generation γ-ray array AGATA

    Energy Technology Data Exchange (ETDEWEB)

    Goasduff, A., E-mail: Alain.Goasduff@csnsm.in2p3.fr [Université de Strasbourg, IPHC, 23 rue du Loess, F-67037 Strasbourg (France); CNRS, UMR 7178, F-67037 Strasbourg (France); CSNSM, UMR 8609, IN2P3-CNRS, Université Paris-Sud 11, F-91405 Orsay Cedex (France); Valiente-Dobón, J.J. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Lunardi, S. [Dipartimento di Fisica e Astronomia, Università di Padova and INFN, Sezione di Padova, I-35131 Padova (Italy); Haas, F. [Université de Strasbourg, IPHC, 23 rue du Loess, F-67037 Strasbourg (France); CNRS, UMR 7178, F-67037 Strasbourg (France); Gadea, A. [Instituto de Física Corpuscular, CSIC-Universitat de València, E-46980 Valencia (Spain); Angelis, G. de [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Bazzacco, D. [Dipartimento di Fisica e Astronomia, Università di Padova and INFN, Sezione di Padova, I-35131 Padova (Italy); Courtin, S. [Université de Strasbourg, IPHC, 23 rue du Loess, F-67037 Strasbourg (France); CNRS, UMR 7178, F-67037 Strasbourg (France); Farnea, E. [Dipartimento di Fisica e Astronomia, Università di Padova and INFN, Sezione di Padova, I-35131 Padova (Italy); Gottardo, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Michelagnoli, C. [Dipartimento di Fisica e Astronomia, Università di Padova and INFN, Sezione di Padova, I-35131 Padova (Italy); and others

    2014-09-11

    The differential Recoil Distance Doppler Shift (RDDS) method after multinucleon transfer (MNT) reactions to measure lifetimes of excited states in neutron-rich nuclei requires the use of a thick energy degrader for the recoiling ejectiles that are then detected in a spectrometer. This type of measurements greatly benefits from the use of the new generation segmented γ-ray detectors, such as the AGATA demonstrator which offers unprecedented energy and angular resolutions. In order to make an optimized choice of the material and the thickness of the degrader for lifetime measurements using the RDDS method after MNT, an experiment has been performed with the AGATA demonstrator. Counting rate measurements for different degraders are presented.

  11. Measured count-rate performance of the Discovery STE PET/CT scanner in 2D, 3D and partial collimation acquisition modes.

    Science.gov (United States)

    Macdonald, L R; Schmitz, R E; Alessio, A M; Wollenweber, S D; Stearns, C W; Ganin, A; Harrison, R L; Lewellen, T K; Kinahan, P E

    2008-07-21

    We measured count rates and scatter fraction on the Discovery STE PET/CT scanner in conventional 2D and 3D acquisition modes, and in a partial collimation mode between 2D and 3D. As part of the evaluation of using partial collimation, we estimated global count rates using a scanner model that combined computer simulations with an empirical live-time function. Our measurements followed the NEMA NU2 count rate and scatter-fraction protocol to obtain true, scattered and random coincidence events, from which noise equivalent count (NEC) rates were calculated. The effect of patient size was considered by using 27 cm and 35 cm diameter phantoms, in addition to the standard 20 cm diameter cylindrical count-rate phantom. Using the scanner model, we evaluated two partial collimation cases: removing half of the septa (2.5D) and removing two-thirds of the septa (2.7D). Based on predictions of the model, a 2.7D collimator was constructed. Count rates and scatter fractions were then measured in 2D, 2.7D and 3D. The scanner model predicted relative NEC variation with activity, as confirmed by measurements. The measured 2.7D NEC was equal or greater than 3D NEC for all activity levels in the 27 cm and 35 cm phantoms. In the 20 cm phantom, 3D NEC was somewhat higher ( approximately 15%) than 2.7D NEC at 100 MBq. For all higher activity concentrations, 2.7D NEC was greater and peaked 26% above the 3D peak NEC. The peak NEC in 2.7D mode occurred at approximately 425 MBq, and was 26-50% greater than the peak 3D NEC, depending on object size. NEC in 2D was considerably lower, except at relatively high activity concentrations. Partial collimation shows promise for improved noise equivalent count rates in clinical imaging without altering other detector parameters.

  12. DETERMINATION OF SATURATION VAPOR PRESSURE OF LOW VOLATILE SUBSTANCES THROUGH THE STUDY OF EVAPORATION RATE BY THERMOGRAVIMETRIC ANALYSIS

    Directory of Open Access Journals (Sweden)

    R. V. Ralys

    2015-11-01

    Full Text Available Subject of Study.Research of vapor pressure of low volatile substances is a complicated problem due to both direct experimental implementation complexity and, most significantly, the issues faced correctness of the analysis and processing of experimental data. That is why it is usually required engaging the reference substances (with vapor pressures well studied. The latter drastically reduces the effectiveness of the experimental methods used and narrows their applicability. The paper deals with an approach to the evaporation process description (sublimation of low volatile substances based on molecular kinetic description in view of diffusive and convection processes. The proposed approach relies on experimental thermogravimetricfindingsina wide range of temperatures, flow rates ofthe purge gas and time. Method. A new approach is based on the calculation of the vapor pressure and uses the data about the speed of evaporation by thermogravimetric analysis depending on the temperature, the flow rate of the purge gas, and the evaporation time. The basis for calculation is the diffusion-kinetic description of the process of evaporation (mass loss of the substance from the exposed surface. The method is applicable to determine the thermodynamic characteristics for both the evaporation (the equilibrium liquid - vapor and sublimation (the equilibrium solid - vapor. We proposed the appropriate method of the experiment and analysis of its data in order to find the saturated vapor pressure of individual substances of low volatility. Main Results. The method has been tested on substances with insufficiently reliable and complete study of the thermodynamic characteristics but, despite this, are often used (because of the other data limitations as reference ones. The vaporization process (liquid-vapor has been studied for di-n-butyl phthalate C16H22O4 at 323,15–443,15 К, and sublimation for benzoic acid C7H6O2at 303,15–183,15 К. Both processes have

  13. CD4 cell count and viral load-specific rates of AIDS, non-AIDS and deaths according to current antiretroviral use

    DEFF Research Database (Denmark)

    Mocroft, Amanda; Phillips, Andrew N; Gatell, Jose

    2013-01-01

    CD4 cell count and viral loads are used in clinical trials as surrogate endpoints for assessing efficacy of newly available antiretrovirals. If antiretrovirals act through other pathways or increase the risk of disease this would not be identified prior to licensing. The aim of this study was to ...... was to investigate the CD4 cell count and viral load-specific rates of fatal and nonfatal AIDS and non-AIDS events according to current antiretrovirals....

  14. Analysis of the power saturation method and using SR-ELDOR and global analysis to extract multiple rates from recovery curves. [SR-ELDOR (Saturation Recovery - Electron Electron Double Resonance)

    Energy Technology Data Exchange (ETDEWEB)

    Haas, D.A.

    1993-01-01

    The possibility is investigated to extending the method of extracting the spin-lattice relaxation rate (R[sub 1e]) from Continuous Wave Electron Paramagnetic Resonance (CW-EPR) lineshapes under saturating conditions beyond the very fast motional region. The signal intensities of simulated [sup 14]N lineshapes under progressive saturation are analyzed for a wide range of motional rates. An adjustable parameter is included in the analysis to account for the changing degree of homogeneity of the EPR spectrum as the motion slows from the fast- to the slow-motion regime. The quantity R[sub 2], determined from the lineshape analysis, is shown to be a valid description of the homogeneous linewidth under saturation. Theoretical models for R[sub 2], constructed from spectral density functions, are compared. The standard theory works very well for motions faster than 5 ns; and, for slower motions, the modified theories qualitatively reproduce R[sub 2]. In the motional range of 10 to 200 ns, R[sub 2] remains roughly constant. This should therefore be the optimal range for obtaining relative values of R[sub 1e]. The electron and nuclear relaxation rates R[sub 1e] and R[sub 1n] have been measured, for the spin label TEMPOL in glycerol-water solutions, over a wide range of motion, from 10[sup [minus]11] to longer than 10[sup [minus]4] seconds. In the range 10[sup [minus]7] to 10[sup [minus]5] seconds, the motional correlation time is measured directly as one component of the SR-ELDOR relaxation curve. The functional dependence of R[sub 1e] and R[sub 1n] on the correlation time is clarified, based on the Electron Nuclear Dipolar effect, spin diffusion, and spin rotation. CW- and Saturation Transfer (ST-) EPR spectra provide independent measures of the correlation time. There is good agreement between simulations and ST-EPR spectra up to 5 [mu]s; for slower motions the simulations require additional convolution to quantitatively fit the data.

  15. Aspartic acid racemization rate in narwhal (Monodon monoceros eye lens nuclei estimated by counting of growth layers in tusks

    Directory of Open Access Journals (Sweden)

    Eva Garde

    2012-11-01

    Full Text Available Ages of marine mammals have traditionally been estimated by counting dentinal growth layers in teeth. However, this method is difficult to use on narwhals (Monodon monoceros because of their special tooth structures. Alternative methods are therefore needed. The aspartic acid racemization (AAR technique has been used in age estimation studies of cetaceans, including narwhals. The purpose of this study was to estimate a species-specific racemization rate for narwhals by regressing aspartic acid d/l ratios in eye lens nuclei against growth layer groups in tusks (n=9. Two racemization rates were estimated: one by linear regression (r2=0.98 based on the assumption that age was known without error, and one based on a bootstrap study, taking into account the uncertainty in the age estimation (r2 between 0.88 and 0.98. The two estimated 2kAsp values were identical up to two significant figures. The 2k Asp value from the bootstrap study was found to be 0.00229±0.000089 SE, which corresponds to a racemization rate of 0.00114−yr±0.000044 SE. The intercept of 0.0580±0.00185 SE corresponds to twice the (d/l0 value, which is then 0.0290±0.00093 SE. We propose that this species-specific racemization rate and (d/l0 value be used in future AAR age estimation studies of narwhals, but also recommend the collection of tusks and eyes of narwhals for further improving the (d/l0 and 2kAsp estimates obtained in this study.

  16. Single-photon counting for the 1300-1600-nm range by use of peltier-cooled and passively quenched InGaAs avalanche photodiodes.

    Science.gov (United States)

    Rarity, J G; Wall, T E; Ridley, K D; Owens, P C; Tapster, P R

    2000-12-20

    We evaluate the performance of various commercially available InGaAs/InP avalanche photodiodes for photon counting in the infrared at temperatures that can be reached by Peltier cooling. We find that dark count rates are high, and this can partially saturate devices before optimum performance is achieved. At low temperatures the dark count rate rises because of a strong contribution from correlated afterpulses. We discuss ways of suppressing these afterpulses for different photon-counting applications.

  17. Estimated average annual rate of change of CD4(+) T-cell counts in patients on combination antiretroviral therapy

    DEFF Research Database (Denmark)

    Mocroft, Amanda; Phillips, Andrew N; Ledergerber, Bruno;

    2010-01-01

    BACKGROUND: Patients receiving combination antiretroviral therapy (cART) might continue treatment with a virologically failing regimen. We sought to identify annual change in CD4(+) T-cell count according to levels of viraemia in patients on cART. METHODS: A total of 111,371 CD4(+) T-cell counts ...

  18. The utility of erythrocyte sedimentation rate values and white blood cell counts after spinal deformity surgery in the early (≤3 months) post-operative period.

    Science.gov (United States)

    Kuhn, Margaret G; Lenke, Lawrence G; Bridwell, Keith H; O'Donnell, June C; Luhmann, Scott J

    2012-03-01

    The erythrocyte sedimentation rate (ESR) and white blood cell (WBC) count are frequently obtained in the work-up of post-operative fever. However, their diagnostic utility depends upon comparison with normative peri-operative trends which have not yet been described. The purpose of this study is to define a range of erythrocyte sedimentation rates and white blood cell counts following spinal instrumentation and fusion in non-infected patients. Seventy-five patients underwent spinal instrumentation and fusion. The erythrocyte sedimentation rate and white blood cell count were recorded pre-operatively, at 3 and 7 days post-operatively, and at 1 and 3 months post-operatively. Both erythrocyte sedimentation rate and white blood cell count trends demonstrated an early peak, followed by a gradual return to normal. Peak erythrocyte sedimentation rates occurred within the first week post-operatively in 98% of patients. Peak white blood cell counts occurred with the first week in 85% of patients. In the absence of infection, the erythrocyte sedimentation rate was abnormally elevated in 78% of patients at 1 month and in 53% of patients at 3 months post-operatively. The white blood cell count was abnormally elevated in only 6% of patients at 1 month post-operatively. Longer surgical time was associated with elevated white cell count at 1 week post-operatively. The fusion of more vertebral levels had a negative relationship with elevated erythrocyte sedimentation rate at 1 week post-operatively. The anterior surgical approach was associated with significantly lower erythrocyte sedimentation rate at 1 month post-operatively and with lower white cell count at 1 week post-operatively. In non-infected spinal fusion surgeries, erythrocyte sedimentation rates are in the abnormal range in 78% of patients at 1 month and in 53% of patients at 3 months post-operatively, suggesting that the erythrocyte sedimentation rate is of limited diagnostic value in the early post

  19. Linking reproduction and survival can improve model estimates of vital rates derived from limited time-series counts of pinnipeds and other species.

    Science.gov (United States)

    Battaile, Brian C; Trites, Andrew W

    2013-01-01

    We propose a method to model the physiological link between somatic survival and reproductive output that reduces the number of parameters that need to be estimated by models designed to determine combinations of birth and death rates that produce historic counts of animal populations. We applied our Reproduction and Somatic Survival Linked (RSSL) method to the population counts of three species of North Pacific pinnipeds (harbor seals, Phoca vitulina richardii (Gray, 1864); northern fur seals, Callorhinus ursinus (L., 1758); and Steller sea lions, Eumetopias jubatus (Schreber, 1776))--and found our model outperformed traditional models when fitting vital rates to common types of limited datasets, such as those from counts of pups and adults. However, our model did not perform as well when these basic counts of animals were augmented with additional observations of ratios of juveniles to total non-pups. In this case, the failure of the ratios to improve model performance may indicate that the relationship between survival and reproduction is redefined or disassociated as populations change over time or that the ratio of juveniles to total non-pups is not a meaningful index of vital rates. Overall, our RSSL models show advantages to linking survival and reproduction within models to estimate the vital rates of pinnipeds and other species that have limited time-series of counts.

  20. Linking reproduction and survival can improve model estimates of vital rates derived from limited time-series counts of pinnipeds and other species.

    Directory of Open Access Journals (Sweden)

    Brian C Battaile

    Full Text Available We propose a method to model the physiological link between somatic survival and reproductive output that reduces the number of parameters that need to be estimated by models designed to determine combinations of birth and death rates that produce historic counts of animal populations. We applied our Reproduction and Somatic Survival Linked (RSSL method to the population counts of three species of North Pacific pinnipeds (harbor seals, Phoca vitulina richardii (Gray, 1864; northern fur seals, Callorhinus ursinus (L., 1758; and Steller sea lions, Eumetopias jubatus (Schreber, 1776--and found our model outperformed traditional models when fitting vital rates to common types of limited datasets, such as those from counts of pups and adults. However, our model did not perform as well when these basic counts of animals were augmented with additional observations of ratios of juveniles to total non-pups. In this case, the failure of the ratios to improve model performance may indicate that the relationship between survival and reproduction is redefined or disassociated as populations change over time or that the ratio of juveniles to total non-pups is not a meaningful index of vital rates. Overall, our RSSL models show advantages to linking survival and reproduction within models to estimate the vital rates of pinnipeds and other species that have limited time-series of counts.

  1. Evaluation of two-stage system for neutron measurement aiming at increase in count rate at Japan Atomic Energy Agency-Fusion Neutronics Source

    Energy Technology Data Exchange (ETDEWEB)

    Shinohara, K., E-mail: shinohara.koji@jaea.go.jp; Ochiai, K.; Sukegawa, A. [Japan Atomic Energy Agency, Naka, Ibaraki 311-0193 (Japan); Ishii, K.; Kitajima, S. [Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Miyagi 980-8579 (Japan); Baba, M. [Cyclotron and Radioisotope Center, Tohoku University, Sendai, Miyagi 980-8578 (Japan); Sasao, M. [Organization for Research Initiatives and Development, Doshisha University, Kyoto 602-8580 (Japan)

    2014-11-15

    In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons. The results suggested that the concept of a multi-stage detection system will work in practice.

  2. Patient-dependent count-rate adaptive normalization for PET detector efficiency with delayed-window coincidence events.

    Science.gov (United States)

    Niu, Xiaofeng; Ye, Hongwei; Xia, Ting; Asma, Evren; Winkler, Mark; Gagnon, Daniel; Wang, Wenli

    2015-07-07

    Quantitative PET imaging is widely used in clinical diagnosis in oncology and neuroimaging. Accurate normalization correction for the efficiency of each line-of- response is essential for accurate quantitative PET image reconstruction. In this paper, we propose a normalization calibration method by using the delayed-window coincidence events from the scanning phantom or patient. The proposed method could dramatically reduce the 'ring' artifacts caused by mismatched system count-rates between the calibration and phantom/patient datasets. Moreover, a modified algorithm for mean detector efficiency estimation is proposed, which could generate crystal efficiency maps with more uniform variance. Both phantom and real patient datasets are used for evaluation. The results show that the proposed method could lead to better uniformity in reconstructed images by removing ring artifacts, and more uniform axial variance profiles, especially around the axial edge slices of the scanner. The proposed method also has the potential benefit to simplify the normalization calibration procedure, since the calibration can be performed using the on-the-fly acquired delayed-window dataset.

  3. Alternative Optimizations of X-ray TES Arrays: Soft X-rays, High Count Rates, and Mixed-Pixel Arrays

    Science.gov (United States)

    Kilbourne, C. A.; Bandler, S. R.; Brown, A.-D.; Chervenak, J. A.; Figueroa-Feliciano, E.; Finkbeiner, F. M.; Iyomoto, N.; Kelley, R. L.; Porter, F. S.; Smith, S. J.

    2007-01-01

    We are developing arrays of superconducting transition-edge sensors (TES) for imaging spectroscopy telescopes such as the XMS on Constellation-X. While our primary focus has been on arrays that meet the XMS requirements (of which, foremost, is an energy resolution of 2.5 eV at 6 keV and a bandpass from approx. 0.3 keV to 12 keV), we have also investigated other optimizations that might be used to extend the XMS capabilities. In one of these optimizations, improved resolution below 1 keV is achieved by reducing the heat capacity. Such pixels can be based on our XMS-style TES's with the separate absorbers omitted. These pixels can added to an array with broadband response either as a separate array or interspersed, depending on other factors that include telescope design and science requirements. In one version of this approach, we have designed and fabricated a composite array of low-energy and broad-band pixels to provide high spectral resolving power over a broader energy bandpass than could be obtained with a single TES design. The array consists of alternating pixels with and without overhanging absorbers. To explore optimizations for higher count rates, we are also optimizing the design and operating temperature of pixels that are coupled to a solid substrate. We will present the performance of these variations and discuss other optimizations that could be used to enhance the XMS or enable other astrophysics experiments.

  4. Heart rate recovery after the 6-min walk test is related to 6-min walk distance and percutaneous oxygen saturation recovery in patients with COPD.

    Science.gov (United States)

    Shiroishi, Ryota; Kitagawa, Chika; Miyamoto, Naomi; Kakuno, Nao; Koyanagi, Harumi; Rikitomi, Naoto; Senjyu, Hideaki

    2015-05-01

    Heart rate recovery (HRR) after maximal load exercise affects mortality in chronic obstructive pulmonary disease (COPD). However, the associations of clinical characteristics with HRR after the 6-min walk test (6MWT), which is defined as a submaximal load test, remain unclear. We showed that HRR in patients with COPD after 6MWT was related to 6-min walk distance and percutaneous oxygen saturation recovery. HRR after the 6MWT may be useful to assess exercise capacity in COPD.

  5. A count-rate model for PET scanners using pixelated Anger-logic detectors with different scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Surti, S; Karp, J S [Department of Radiology, University of Pennsylvania, 110 Donner Building (HUP), 3400 Spruce Street, Philadelphia, PA 19104 (United States)

    2005-12-07

    A high count-rate simulation (HCRSim) model has been developed so that all results are derived from fundamental physics principles. Originally developed to study the behaviour of continuous sodium iodide (NaI(Tl)) detectors, this model is now applied to PET scanners based on pixelated Anger-logic detectors using lanthanum bromide (LaBr{sub 3}), gadolinium orthosilicate (GSO) and lutetium orthosilicate (LSO) scintillators. This simulation has been used to study the effect on scanner deadtime and pulse pileup at high activity levels due to the scintillator stopping power ({mu}), decay time ({tau}) and energy resolution. Simulations were performed for a uniform 20 cm diameter x 70 cm long cylinder (NEMA NU2-2001 standard) in a whole-body scanner with an 85 cm ring diameter and a 25 cm axial field-of-view. Our results for these whole-body scanners demonstrate the potential of a pixelated Anger-logic detector and the relationship of its performance with the scanner NEC rate. Faster signal decay and short coincidence timing window lead to a reduction in deadtime and randoms fraction in the LaBr{sub 3} and LSO scanners compared to GSO. The excellent energy resolution of LaBr{sub 3} leads to the lowest scatter fraction for all scanners and helps compensate for reduced sensitivity compared to the GSO and LSO scanners, leading to the highest NEC values at high activity concentrations. The LSO scanner has the highest sensitivity of all the scanner designs investigated here, therefore leading to the highest peak NEC value but at a lower activity concentration than that of LaBr{sub 3}.

  6. A count-rate model for PET scanners using pixelated Anger-logic detectors with different scintillators.

    Science.gov (United States)

    Surti, S; Karp, J S

    2005-12-07

    A high count-rate simulation (HCRSim) model has been developed so that all results are derived from fundamental physics principles. Originally developed to study the behaviour of continuous sodium iodide (NaI(Tl)) detectors, this model is now applied to PET scanners based on pixelated Anger-logic detectors using lanthanum bromide (LaBr(3)), gadolinium orthosilicate (GSO) and lutetium orthosilicate (LSO) scintillators. This simulation has been used to study the effect on scanner deadtime and pulse pileup at high activity levels due to the scintillator stopping power (mu), decay time (tau) and energy resolution. Simulations were performed for a uniform 20 cm diameter x 70 cm long cylinder (NEMA NU2-2001 standard) in a whole-body scanner with an 85 cm ring diameter and a 25 cm axial field-of-view. Our results for these whole-body scanners demonstrate the potential of a pixelated Anger-logic detector and the relationship of its performance with the scanner NEC rate. Faster signal decay and short coincidence timing window lead to a reduction in deadtime and randoms fraction in the LaBr(3) and LSO scanners compared to GSO. The excellent energy resolution of LaBr(3) leads to the lowest scatter fraction for all scanners and helps compensate for reduced sensitivity compared to the GSO and LSO scanners, leading to the highest NEC values at high activity concentrations. The LSO scanner has the highest sensitivity of all the scanner designs investigated here, therefore leading to the highest peak NEC value but at a lower activity concentration than that of LaBr(3).

  7. Comparison of O2 saturation, heart and respiratory rate following injection of vasoconstrictor containing anesthetic (lidocaine 2% and without vasoconstrictor anesthetic (Mepivacaine

    Directory of Open Access Journals (Sweden)

    Bayat M.

    2005-07-01

    Full Text Available Background and Aim: Along with higher usage of dental local anesthesia with risks to people health together with their positive role, the important goal of dentistry, patients’ health, has been stressed repeatedly nowadays. This study was conducted to compare O2 saturation, respiratory rate and heart rate of patients following injection of anesthetic containing vasoconstrictor (lidocaine 2% and without vasoconstrictor (Mepivacaine. Materials and Methods: This experimental study was conducted on 32 healthy humans (16 females and 16 males with 25-50 years age range and no history of drug usage. Cases were classified into two matched groups. O2 saturation, heart and respiratory rate were recorded before extraction of a mandibular posterior tooth. In the first group, 3.6 ml lidocaine 2% with 1:80,000 epinephrine and in the second group Mepivacaine 3% was injected, using inferior alveolar dental nerve block with aspiration. Variables were measured and recorded. Tooth extraction was performed and the mentioned variables were recorded again. Data were analyzed with SPSS software using t and Paired t-test with P<0.05 as the limit of significance. Results: After injection of lidocaine, the heart rate was increased (12.25±1.75 bpm, and the time to reach the maximum rate was 64.75±11.26 seconds. After extraction of tooth, heart rate in both groups was increased not considering the type of injection. Conclusion: The study showed that the injection of lidocaine (containing epinephrine in patients without contraindication has no risk. Also, possible increase in heart rate is not risky and is not associated with O2 saturation decrease and respiratory interruption.

  8. Relationship of long-term highly active antiretroviral therapy on salivary flow rate and CD4 Count among HIV-infected patients

    Directory of Open Access Journals (Sweden)

    J Vijay Kumar

    2015-01-01

    Full Text Available Objectives: To determine if long-term highly active antiretroviral therapy (HAART therapy alters salivary flow rate and also to compare its relation of CD4 count with unstimulated and stimulated whole saliva. Materials and Methods: A cross-sectional study was performed on 150 individuals divided into three groups. Group I (50 human immunodeficiency virus (HIV seropositive patients, but not on HAART therapy, Group II (50 HIV-infected subjects and on HAART for less than 3 years called short-term HAART, Group III (50 HIV-infected subjects and on HAART for more than or equal to 3 years called long-term HAART. Spitting method proposed by Navazesh and Kumar was used for the measurement of unstimulated and stimulated salivary flow rate. Chi-square test and analysis of variance (ANOVA were used for statistical analysis. Results: The mean CD4 count was 424.78 ΁ 187.03, 497.82 ΁ 206.11 and 537.6 ΁ 264.00 in the respective groups. Majority of the patients in all the groups had a CD4 count between 401 and 600. Both unstimulated and stimulated whole salivary (UWS and SWS flow rates in Group I was found to be significantly higher than in Group II (P < 0.05. Unstimulated salivary flow rate between Group II and III subjects were also found to be statistically significant (P < 0.05. ANOVA performed between CD4 count and unstimulated and stimulated whole saliva in each group demonstrated a statistically significant relationship in Group II (P < 0.05. There were no significant results found between CD4 count and stimulated whole saliva in each groups. Conclusion:The reduction in CD4 cell counts were significantly associated with salivary flow rates of HIV-infected individuals who are on long-term HAART.

  9. Association between minor loading vein architecture and light- and CO2-saturated rates of photosynthetic oxygen evolution among Arabidopsis thaliana ecotypes from different latitudes

    Directory of Open Access Journals (Sweden)

    Christopher M Cohu

    2013-07-01

    Full Text Available Through microscopic analysis of veins and assessment of light- and CO2-saturated rates of photosynthetic oxygen evolution, we investigated the relationship between minor loading vein anatomy and photosynthesis of mature leaves in three ecotypes of Arabidopsis thaliana grown under four different combinations of temperature and photon flux density (PFD. All three ecotypes exhibited greater numbers and cross-sectional area of phloem cells as well as higher photosynthesis rates in response to higher PFD and especially lower temperature. The Swedish ecotype exhibited the strongest response to these conditions, the Italian ecotype the weakest response, and the Col-0 ecotype exhibited an intermediate response. Among all three ecotypes, strong linear relationships were found between light- and CO2-saturated rates of photosynthetic oxygen evolution and the number and area of either sieve elements or of companion and phloem parenchyma cells in foliar minor loading veins, with the Swedish ecotype showing the highest number of cells in minor loading veins (and largest minor veins coupled with unprecedented high rates of photosynthesis. Linear, albeit less significant, relationships were also observed between number and cross-sectional area of tracheids per minor loading vein versus light- and CO2-saturated rates of photosynthetic oxygen evolution. We suggest that sugar distribution infrastructure in the phloem is co-regulated with other features that set the upper limit for photosynthesis. The apparent genetic differences among Arabidopsis ecotypes should allow for future identification of the gene(s involved in augmenting sugar-loading and -transporting phloem cells and maximal rates of photosynthesis.

  10. Derivation of a formula describing the saturation correction of plane-parallel ionization chambers in pulsed fields with arbitrary repetition rate.

    Science.gov (United States)

    Karsch, Leonhard

    2016-04-21

    Gas-filled ionization chambers are widely used radiation detectors in radiotherapy. A quantitative description and correction of the recombination effects exists for two cases, for continuous radiation exposure and for pulsed radiation fields with short single pulses. This work gives a derivation of a formula for pulsed beams with arbitrary pulse rate for which the prerequisites of the two existing descriptions are not fulfilled. Furthermore, an extension of the validity of the two known cases is investigated. The temporal evolution of idealized charge density distributions within a plane parallel chamber volume is described for pulsed beams of vanishing pulse duration and arbitrary pulse repetition rate. First, the radiation induced release, movement and collection of the charge carriers without recombination are considered. Then, charge recombination is calculated basing on these simplified charge distributions and the time dependent spatial overlap of positive and negative charge carrier distributions. Finally, a formula for the calculation of the saturation correction factor is derived by calculation and simplification of the first two terms of a Taylor expansion for small recombination. The new formula of saturation correction contains the two existing cases, descriptions for exposure by single pulses and continuous irradiation, as limiting cases. Furthermore, it is possible to determine the pulse rate range for which each of the three descriptions is applicable by comparing the dependencies of the new formula with the two existing cases. As long as the time between two pulses is lower than one third of the collection time of the chamber, the formalism for a continuous exposure can be used. The known description for single pulse irradiation is only valid if the repetition rate is less than 1.2 times the inverse collection time. For all other repetition rates in between the new formula should be used. The experimental determination by Jaffe diagrams can be

  11. Derivation of a formula describing the saturation correction of plane-parallel ionization chambers in pulsed fields with arbitrary repetition rate

    Science.gov (United States)

    Karsch, Leonhard

    2016-04-01

    Gas-filled ionization chambers are widely used radiation detectors in radiotherapy. A quantitative description and correction of the recombination effects exists for two cases, for continuous radiation exposure and for pulsed radiation fields with short single pulses. This work gives a derivation of a formula for pulsed beams with arbitrary pulse rate for which the prerequisites of the two existing descriptions are not fulfilled. Furthermore, an extension of the validity of the two known cases is investigated. The temporal evolution of idealized charge density distributions within a plane parallel chamber volume is described for pulsed beams of vanishing pulse duration and arbitrary pulse repetition rate. First, the radiation induced release, movement and collection of the charge carriers without recombination are considered. Then, charge recombination is calculated basing on these simplified charge distributions and the time dependent spatial overlap of positive and negative charge carrier distributions. Finally, a formula for the calculation of the saturation correction factor is derived by calculation and simplification of the first two terms of a Taylor expansion for small recombination. The new formula of saturation correction contains the two existing cases, descriptions for exposure by single pulses and continuous irradiation, as limiting cases. Furthermore, it is possible to determine the pulse rate range for which each of the three descriptions is applicable by comparing the dependencies of the new formula with the two existing cases. As long as the time between two pulses is lower than one third of the collection time of the chamber, the formalism for a continuous exposure can be used. The known description for single pulse irradiation is only valid if the repetition rate is less than 1.2 times the inverse collection time. For all other repetition rates in between the new formula should be used. The experimental determination by Jaffe diagrams can be

  12. High-voltage integrated active quenching circuit for single photon count rate up to 80 Mcounts/s.

    Science.gov (United States)

    Acconcia, Giulia; Rech, Ivan; Gulinatti, Angelo; Ghioni, Massimo

    2016-08-01

    Single photon avalanche diodes (SPADs) have been subject to a fast improvement in recent years. In particular, custom technologies specifically developed to fabricate SPAD devices give the designer the freedom to pursue the best detector performance required by applications. A significant breakthrough in this field is represented by the recent introduction of a red enhanced SPAD (RE-SPAD) technology, capable of attaining a good photon detection efficiency in the near infrared range (e.g. 40% at a wavelength of 800 nm) while maintaining a remarkable timing resolution of about 100ps full width at half maximum. Being planar, the RE-SPAD custom technology opened the way to the development of SPAD arrays particularly suited for demanding applications in the field of life sciences. However, to achieve such excellent performance custom SPAD detectors must be operated with an external active quenching circuit (AQC) designed on purpose. Next steps toward the development of compact and practical multichannel systems will require a new generation of monolithically integrated AQC arrays. In this paper we present a new, fully integrated AQC fabricated in a high-voltage 0.18 µm CMOS technology able to provide quenching pulses up to 50 Volts with fast leading and trailing edges. Although specifically designed for optimal operation of RE-SPAD devices, the new AQC is quite versatile: it can be used with any SPAD detector, regardless its fabrication technology, reaching remarkable count rates up to 80 Mcounts/s and generating a photon detection pulse with a timing jitter as low as 119 ps full width at half maximum. The compact design of our circuit has been specifically laid out to make this IC a suitable building block for monolithically integrated AQC arrays.

  13. Pulse shape discrimination of Cs2LiYCl6:Ce3+ detectors at high count rate based on triangular and trapezoidal filters

    Science.gov (United States)

    Wen, Xianfei; Enqvist, Andreas

    2017-09-01

    Cs2LiYCl6:Ce3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. A disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. They are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

  14. Phase space representation of neutron monitor count rate and atmospheric electric field in relation to solar activity in cycles 21 and 22.

    Science.gov (United States)

    Silva, H G; Lopes, I

    Heliospheric modulation of galactic cosmic rays links solar cycle activity with neutron monitor count rate on earth. A less direct relation holds between neutron monitor count rate and atmospheric electric field because different atmospheric processes, including fluctuations in the ionosphere, are involved. Although a full quantitative model is still lacking, this link is supported by solid statistical evidence. Thus, a connection between the solar cycle activity and atmospheric electric field is expected. To gain a deeper insight into these relations, sunspot area (NOAA, USA), neutron monitor count rate (Climax, Colorado, USA), and atmospheric electric field (Lisbon, Portugal) are presented here in a phase space representation. The period considered covers two solar cycles (21, 22) and extends from 1978 to 1990. Two solar maxima were observed in this dataset, one in 1979 and another in 1989, as well as one solar minimum in 1986. Two main observations of the present study were: (1) similar short-term topological features of the phase space representations of the three variables, (2) a long-term phase space radius synchronization between the solar cycle activity, neutron monitor count rate, and potential gradient (confirmed by absolute correlation values above ~0.8). Finally, the methodology proposed here can be used for obtaining the relations between other atmospheric parameters (e.g., solar radiation) and solar cycle activity.

  15. A new approach to assess the dependency of extant half-saturation coefficients on maximum process rates and estimate intrinsic coefficients.

    Science.gov (United States)

    Shaw, A; Takács, I; Pagilla, K R; Murthy, S

    2013-10-15

    The Monod equation is often used to describe biological treatment processes and is the foundation for many activated sludge models. The Monod equation includes a "half-saturation coefficient" to describe the effect of substrate limitations on the process rate and it is customary to consider this parameter to be a constant for a given system. The purpose of this study was to develop a methodology, and its use to show that the half-saturation coefficient for denitrification is not constant but is in fact a function of the maximum denitrification rate. A 4-step procedure is developed to investigate the dependency of half-saturation coefficients on the maximum rate and two different models are used to describe this dependency: (a) an empirical linear model and (b) a deterministic model based on Fick's law of diffusion. Both models are proved better for describing denitrification kinetics than assuming a fixed K(NO3) at low nitrate concentrations. The empirical model is more utilitarian whereas the model based on Fick's law has a fundamental basis that enables the intrinsic K(NO3) to be estimated. In this study data was analyzed from 56 denitrification rate tests and it was found that the extant K(NO3) varied between 0.07 mgN/L and 1.47 mgN/L (5th and 95th percentile respectively) with an average of 0.47 mgN/L. In contrast to this, the intrinsic K(NO3) estimated for the diffusion model was 0.01 mgN/L which indicates that the extant K(NO3) is greatly influenced by, and mostly describes, diffusion limitations.

  16. Quantitative chemical exchange saturation transfer (qCEST) MRI--RF spillover effect-corrected omega plot for simultaneous determination of labile proton fraction ratio and exchange rate.

    Science.gov (United States)

    Sun, Phillip Zhe; Wang, Yu; Dai, ZhuoZhi; Xiao, Gang; Wu, Renhua

    2014-01-01

    Chemical exchange saturation transfer (CEST) MRI is sensitive to dilute proteins and peptides as well as microenvironmental properties. However, the complexity of the CEST MRI effect, which varies with the labile proton content, exchange rate and experimental conditions, underscores the need for developing quantitative CEST (qCEST) analysis. Towards this goal, it has been shown that omega plot is capable of quantifying paramagnetic CEST MRI. However, the use of the omega plot is somewhat limited for diamagnetic CEST (DIACEST) MRI because it is more susceptible to direct radio frequency (RF) saturation (spillover) owing to the relatively small chemical shift. Recently, it has been found that, for dilute DIACEST agents that undergo slow to intermediate chemical exchange, the spillover effect varies little with the labile proton ratio and exchange rate. Therefore, we postulated that the omega plot analysis can be improved if RF spillover effect could be estimated and taken into account. Specifically, simulation showed that both labile proton ratio and exchange rate derived using the spillover effect-corrected omega plot were in good agreement with simulated values. In addition, the modified omega plot was confirmed experimentally, and we showed that the derived labile proton ratio increased linearly with creatine concentration (p exchange rate (p = 0.32). In summary, our study extends the conventional omega plot for quantitative analysis of DIACEST MRI.

  17. Association between Resting Heart Rate and Inflammatory Markers (White Blood Cell Count and High-Sensitivity C-Reactive Protein) in Healthy Korean People.

    Science.gov (United States)

    Park, Woo-Chul; Seo, Inho; Kim, Shin-Hye; Lee, Yong-Jae; Ahn, Song Vogue

    2017-01-01

    Inflammation is an important underlying mechanism in the pathogenesis of atherosclerosis, and an elevated resting heart rate underlies the process of atherosclerotic plaque formation. We hypothesized an association between resting heart rate and subclinical inflammation. Resting heart rate was recorded at baseline in the KoGES-ARIRANG (Korean Genome and Epidemiology Study on Atherosclerosis Risk of Rural Areas in the Korean General Population) cohort study, and was then divided into quartiles. Subclinical inflammation was measured by white blood cell count and high-sensitivity C-reactive protein. We used progressively adjusted regression models with terms for muscle mass, body fat proportion, and adiponectin in the fully adjusted models. We examined inflammatory markers as both continuous and categorical variables, using the clinical cut point of the highest quartile of white blood cell count (≥7,900/mm(3)) and ≥3 mg/dL for high-sensitivity C-reactive protein. Participants had a mean age of 56.3±8.1 years and a mean resting heart rate of 71.4±10.7 beats/min; 39.1% were men. In a fully adjusted model, an increased resting heart rate was significantly associated with a higher white blood cell count and higher levels of high-sensitivity C-reactive protein in both continuous (P for trend heart rate is associated with a higher level of subclinical inflammation among healthy Korean people.

  18. Transport of sucrose-modified nanoscale zero-valent iron in saturated porous media: role of media size, injection rate and input concentration.

    Science.gov (United States)

    Li, Hui; Zhao, Yong-sheng; Han, Zhan-tao; Hong, Mei

    2015-01-01

    The growing use of nanoscale zero-valent iron (NZVI) in the remediation of contaminated groundwater raises concerns regarding its transport in aquifers. Laboratory-scale sand-packed column experiments were conducted with bare and sucrose-modified NZVI (SM-NZVI) to improve our understanding of the transport of the nanoparticles in saturated porous media, as well as the role of media size, suspension injection rate and concentration on the nanoparticle behavior. As the main indicative parameters, the normalized effluent concentration was measured and the deposition rate coefficient (k) was calculated for different simulated conditions. Overall, compared to the high retention of bare NZVI in the saturated silica column, SM-NZVI suspension could travel through the coarse sand column easily. However, the transport of SM-NZVI particles was not very satisfactory in a smaller size granular matrix especially in fine silica sand. Furthermore, the value of k regularly decreased with the increasing injection rate of suspension but increased with suspension concentration, which could reflect the role of these factors in the SM-NZVI travel process. The calculation of k-value at the tests condition adequately described the experimental results from the point of deposition dynamics, which meant the assumption of first-order deposition kinetics for the transport of NZVI particles was reasonable and feasible.

  19. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  20. Seal Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Database of seal counts from aerial photography. Counts by image, site, species, and date are stored in the database along with information on entanglements and...

  1. Platelet Count

    Science.gov (United States)

    ... their spleen removed surgically Use of birth control pills (oral contraceptives) Some conditions may cause a temporary (transitory) increased ... increased platelet counts include estrogen and birth control pills (oral contraceptives). Mildly decreased platelet counts may be seen in ...

  2. The Intrinsic Count Rate Test For SIEMENS LSO Scintillator Detectors PET/CT%SIEMENS LSO晶体PET/CT的本底计数测试

    Institute of Scientific and Technical Information of China (English)

    欧阳习; 尹吉林; 李小华

    2009-01-01

    目的 测量SIEMENS LSO晶体PET/CT的本底计数.方法 利用仪器本身的Syngo软件中PET Monitor工具或作一个床位的PET/CT空白扫描,测试一台SIEMENS Biograph 16HK PET/CT的LSO晶体本底计数.结果 SIEMENS BIOGRAPH 16HR PET/CT的LSO晶体本底计数率约为net trues:4.5counts/s、Randorm:545counts/s、Prompts:550counts/s、Single Rate:745750counts/s.标准差SD分别为:0.26、2.52、1.53、7656.24.结论 作一次一个床位6分钟PET/CT空白扫描,是测试LSO晶体PET/CT的本底计数率简单而又适用的方法.

  3. Neutron Monitors and muon detectors for solar modulation studies: Interstellar flux, yield function, and assessment of critical parameters in count rate calculations

    CERN Document Server

    Maurin, D; Derome, L; Ghelfi, A; Hubert, G

    2014-01-01

    Particles count rates at given Earth location and altitude result from the convolution of (i) the interstellar (IS) cosmic-ray fluxes outside the solar cavity, (ii) the time-dependent modulation of IS into Top-of-Atmosphere (TOA) fluxes, (iii) the rigidity cut-off (or geomagnetic transmission function) and grammage at the counter location, (iv) the atmosphere response to incoming TOA cosmic rays (shower development), and (v) the counter response to the various particles/energies in the shower. Count rates from neutron monitors or muon counters are therefore a proxy to solar activity. In this paper, we review all ingredients, discuss how their uncertainties impact count rate calculations, and how they translate into variation/uncertainties on the level of solar modulation $\\phi$ (in the simple Force-Field approximation). The main uncertainty for neutron monitors is related to the yield function. However, many other effects have a significant impact, at the 5-10% level on $\\phi$ values. We find no clear ranking...

  4. Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall

    CERN Document Server

    Petriş, M; Caragheorgheopol, G.; Deppner, I.; Frühauf, J.; Herrmann, N.; Kiš, M.; Loizeau, P-A.; Petrovici, M.; Rǎdulescu, L.; Simion, V.; Simon, C.

    2016-01-01

    Multi-gap RPC prototypes with readout on a multi-strip electrode were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on low resistivity ($\\sim$10$^{10}$ $\\Omega$cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the impedance matching with the front-end electronics and the granularity requirements of the innermost zone of the CBM-TOF wall. The in-beam tests using secondary particles produced in heavy ion collisions on a Pb target at SIS18 - GSI Darmstadt and SPS - CERN were focused on the performance of the prototype in conditions similar to the ones expected at SIS100/FAIR. An efficiency larger than 98\\% and a system time resolution in the order of 70~-~80~ps were obtained in high counting rate and high multiplicity environment.

  5. Time and position resolution of high granularity, high counting rate MRPC for the inner zone of the CBM-TOF wall

    Science.gov (United States)

    Petriş, M.; Bartoş, D.; Caragheorgheopol, G.; Deppner, I.; Frühauf, J.; Herrmann, N.; Kiš, M.; Loizeau, P.-A.; Petrovici, M.; Rădulescu, L.; Simion, V.; Simon, C.

    2016-09-01

    Multi-gap RPC prototypes with a multi-strip-electrode readout were developed for the small polar angle region of the CBM-TOF subdetector, the most demanding zone in terms of granularity and counting rate. The prototypes are based on using low resistivity (~ 1010 Ω·cm) glass electrodes for performing in high counting rate environment. The strip width/pitch size was chosen such to fulfill the impedance matching with the front-end electronics and the granularity requirements of the innermost zone of the CBM-TOF wall. The in-beam tests using secondary particles produced in heavy ion collisions on a Pb target at SIS18—GSI Darmstadt and SPS—CERN were focused on the performance of the prototypes in conditions similar to the ones expected at SIS100/FAIR. An efficiency larger than 98% and a system time resolution in the order of 70-80 ps were obtained in high counting rate and high multiplicity environment.

  6. Saturation-recovery metabolic‐exchange rate imaging with hyperpolarized [1‐13C] pyruvate using spectral‐spatial excitation

    DEFF Research Database (Denmark)

    Schulte, Rolf F.; Sperl, Jonathan I.; Weidl, Eliane

    2013-01-01

    Within the last decade hyperpolarized [1‐13C] pyruvate chemical‐shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time......‐recovery” scheme with the detected signal content being determined by forward conversion of the available pyruvate. In case of repetitive excitations, the polarization is preserved using smaller flip angles for pyruvate. Metabolic exchange rates are determined spatially resolved from the metabolite images using...

  7. Group epitope mapping considering relaxation of the ligand (GEM-CRL): Including longitudinal relaxation rates in the analysis of saturation transfer difference (STD) experiments

    Science.gov (United States)

    Kemper, Sebastian; Patel, Mitul K.; Errey, James C.; Davis, Benjamin G.; Jones, Jonathan A.; Claridge, Timothy D. W.

    2010-03-01

    In the application of saturation transfer difference (STD) experiments to the study of protein-ligand interactions, the relaxation of the ligand is one of the major influences on the experimentally observed STD factors, making interpretation of these difficult when attempting to define a group epitope map (GEM). In this paper, we describe a simplification of the relaxation matrix that may be applied under specified experimental conditions, which results in a simplified equation reflecting the directly transferred magnetisation rate from the protein onto the ligand, defined as the summation over the whole protein of the protein-ligand cross-relaxation multiplied by with the fractional saturation of the protein protons. In this, the relaxation of the ligand is accounted for implicitly by inclusion of the experimentally determined longitudinal relaxation rates. The conditions under which this "group epitope mapping considering relaxation of the ligand" (GEM-CRL) can be applied were tested on a theoretical model system, which demonstrated only minor deviations from that predicted by the full relaxation matrix calculations (CORCEMA-ST) [7]. Furthermore, CORCEMA-ST calculations of two protein-saccharide complexes (Jacalin and TreR) with known crystal structures were performed and compared with experimental GEM-CRL data. It could be shown that the GEM-CRL methodology is superior to the classical group epitope mapping approach currently used for defining ligand-protein proximities. GEM-CRL is also useful for the interpretation of CORCEMA-ST results, because the transferred magnetisation rate provides an additional parameter for the comparison between measured and calculated values. The independence of this parameter from the above mentioned factors can thereby enhance the value of CORCEMA-ST calculations.

  8. Association between Resting Heart Rate and Inflammatory Markers (White Blood Cell Count and High-Sensitivity C-Reactive Protein) in Healthy Korean People

    Science.gov (United States)

    Park, Woo-Chul; Seo, Inho; Kim, Shin-Hye

    2017-01-01

    Background Inflammation is an important underlying mechanism in the pathogenesis of atherosclerosis, and an elevated resting heart rate underlies the process of atherosclerotic plaque formation. We hypothesized an association between resting heart rate and subclinical inflammation. Methods Resting heart rate was recorded at baseline in the KoGES-ARIRANG (Korean Genome and Epidemiology Study on Atherosclerosis Risk of Rural Areas in the Korean General Population) cohort study, and was then divided into quartiles. Subclinical inflammation was measured by white blood cell count and high-sensitivity C-reactive protein. We used progressively adjusted regression models with terms for muscle mass, body fat proportion, and adiponectin in the fully adjusted models. We examined inflammatory markers as both continuous and categorical variables, using the clinical cut point of the highest quartile of white blood cell count (≥7,900/mm3) and ≥3 mg/dL for high-sensitivity C-reactive protein. Results Participants had a mean age of 56.3±8.1 years and a mean resting heart rate of 71.4±10.7 beats/min; 39.1% were men. In a fully adjusted model, an increased resting heart rate was significantly associated with a higher white blood cell count and higher levels of high-sensitivity C-reactive protein in both continuous (P for trend <0.001) and categorical (P for trend <0.001) models. Conclusion An increased resting heart rate is associated with a higher level of subclinical inflammation among healthy Korean people.

  9. Screening of Newborn Saturation

    Directory of Open Access Journals (Sweden)

    Senem Ozgur

    2014-08-01

    Full Text Available In terms of the incidence, congenital heart diseases ranks first among congenital problems in the neonatal period. Although some of those diseases are with significant clinical findings, they might be insignificant in most cases. Standardization methods have been studied in variety of points, and oxygen saturation by pulse oximetry is thougt to be a good alternative to physical examination. In several studies, it is mentioned that some of congenital heart diseases are diagnosed by saturation screening. However, the benefits of this method are marred with the false negative and false positive rates. Therefore, in 2011 American Academy of Pediatrics has revised its saturation algorithm for scanning. It was aimed to have a standardization in saturation detecting time and evaluation of achieved saturation in newborns. Despite all efforts, some newborns with congenital heart disease are not diagnosed before discharging. We beleive that the details of saturation measurements are needed to be carefully evaluated because although these measurements are widely used their details are not well known. [Archives Medical Review Journal 2014; 23(4.000: 587-604

  10. [Relationship between white blood cell count, neutrophils ratio and erythrocyte sedimentation rate and short clinical outcomes among patients with acute ischemic stroke at hospital admission].

    Science.gov (United States)

    Ye, Jia-kai; Zhang, Jin-tao; Kong, Yan; Xu, Tan; Zou, Ting-ting; Zhang, Yong-hong; Zhang, Shao-yan

    2012-09-01

    To investigate the relationship between white blood cell count, neutrophils ratio and erythrocyte sedimentation rate and short outcomes among patients with acute ischemic stroke at admission to the hospital. A total of 2675 acute ischemic stroke patients were included in this study. Data on demographic characteristics, life style, history of disease, white blood cell count (WBC), neutrophils ratio (NEUR), erythrocyte sedimentation rate (ESR) and clinical outcomes were collected for all the participants. Poor clinical outcome was defined as neurologic deficiency (NIHSS ≥ 5) at discharge or death during hospitalization. White blood cell count, neutrophils ratio and erythrocyte sedimentation rate were higher in patients with poor outcome than in those without clinical outcome. According to the quartile range, WBC, NEUR and ESR were divided into four levels at admission. After adjustment for multivariate, compared with WBC ≤ 5.6× 10(9)/L, the odds ratio (95% confidence intervals) of poor outcome with ≥ 8.7×10(9)/L was 1.883 (1.306 - 2.716). When compared with NEUR ≤ 0.56, the odds ratio (95% confidence intervals) of poor outcome with 0.57 - 0.64 and with ≥ 0.74 were 1.572 (1.002 - 2.466) and 2.577 (1.698 - 3.910), respectively. When compared with ESR ≤ 4 mm/h, the odds ratio (95% confidence intervals) of poor outcome with ≥ 17 mm/h was 2.426 (1.233 - 4.776). Elevated WBC count and NEUR at admission were significantly and positively associated with poor clinical outcomes among patients with acute ischemic stroke (trend test P acute ischemic stroke (trend test P > 0.05). There appeared associations between WBC, NEUR, ESR and poor outcome among patients with acute ischemic stroke at admission to the hospital. Both elevated WBC count and NEUR showed significantly positive association with poor clinical outcomes among patients with acute ischemic stroke at admission.

  11. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  12. Improved measurement of labile proton concentration-weighted chemical exchange rate (kws) with experimental factor-compensated and T1-normalized quantitative chemical exchange saturation transfer (CEST) MRI

    Science.gov (United States)

    Wu, Renhua; Liu, Charng-Ming; Liu, Philip K; Sun, Phillip Zhe

    2012-01-01

    Chemical exchange saturation transfer (CEST) MRI enables measurement of dilute CEST agents and microenvironment properties such as pH and temperature, holding great promise for in vivo applications. However, because of confounding concomitant RF irradiation and relaxation effects, the CEST-weighted MRI contrast may not fully characterize the underlying CEST phenomenon. We postulated that the accuracy of quantitative CEST MRI could be improved if the experimental factors (labeling efficiency and RF spillover effect) were estimated and taken into account. Specifically, the experimental factor was evaluated as a function of exchange rate and CEST agent concentration ratio, which remained relatively constant for intermediate RF irradiation power levels. Hence, the experimental factors can be calculated based on the reasonably estimated exchange rate and labile proton concentration ratio, which significantly improved quantification. The simulation was confirmed with Creatine phantoms of serially varied concentration titrated to the same pH, whose reverse exchange rate (kws) was found to be linearly correlated with the concentration. In summary, the proposed solution provides simplified yet reasonably accurate quantification of the underlying CEST system, which may help guide the ongoing development of quantitative CEST MRI. PMID:22649044

  13. Emission Rates, Pre-eruption Gas-Saturation and Ascent Degassing During the 2004-2005 Eruption of Mount St. Helens

    Science.gov (United States)

    Gerlach, T. M.; McGee, K. A.; Doukas, M. P.

    2005-12-01

    Intermittent airborne measurements of volcanic gases began on 27 September 2004 during the initial unrest. Target gases included CO2, SO2 and H2S. The average emission rates through the end of July 2005 were approximately 650 metric tons/day (t/d) CO2 and 100 t/d SO2; H2S was always released and the estimated amount of melt supplied from depth (46 Mt) indicate the dacite would have been gas-saturated at plausible chamber depths. Data on the S content of melt inclusions and matrix glasses underestimate observed SO2 emissions by over a factor of five, corroborating pre-eruption gas saturation of the dacite. Using the 1980 magma equilibration depth (8 km) for comparison and assuming a similar water content (5 wt%) for the rhyolitic melt fraction (Rutherford, 1993; Blundy and Cashman, 2001) give a gas fraction constrained by H2O-CO2 solubility data of 1-2 vol% for the dacite. This compares with an estimate of 10-15 vol% for the 1980 dacite prior to eruption and of 5-30 vol% for common intermediate to silicic magmas (Wallace, 2003). Closed system ascent degassing calculations show that the volume fraction of gas increases to 8 vol% at 4-5 km and reaches 50 vol% at 1 km, where final solidification begins. The gas fraction can potentially increase to >60 vol% during solidification. Allowing for gas separation during extrusion, these results are consistent with observed dacite vesicle fractions averaging 25 vol% (Pallister et al. this session). Ascent degassing calculations also predict melt water contents similar to values measured on rare glassy dacite fragments last equilibrated at depths of 1.2-1.8 km (Mandeville this session).

  14. Determination of Pu content in a Spent Fuel Assembly by Measuring Passive Total Neutron count rate and Multiplication with the Differential Die-Away Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Henzl, Vladimir [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Swinhoe, Martyn T. [Los Alamos National Laboratory; Tobin, Stephen J. [Los Alamos National Laboratory

    2012-07-13

    Inspired by approach of Bignan and Martin-Didier (ESARDA 1991) we introduce novel (instrument independent) approach based on multiplication and passive neutron. Based on simulations of SFL-1 the accuracy of determination of {sup tot}Pu content with new approach is {approx}1.3-1.5%. Method applicable for DDA instrument, since it can measure both multiplication and passive neutron count rate. Comparison of pro's & con's of measuring/determining of {sup 239}Pu{sub eff} and {sup tot}Pu suggests a potential for enhanced diversion detection sensitivity.

  15. Proposal for a GHz count rate near-IR single-photon detector based on a nanoscale superconducting transition edge sensor

    CERN Document Server

    Santavicca, Daniel F; Prober, Daniel E; 10.1117/12.883979

    2012-01-01

    We describe a superconducting transition edge sensor based on a nanoscale niobium detector element. This device is predicted to be capable of energy-resolved near-IR single-photon detection with a GHz count rate. The increased speed and sensitivity of this device compared to traditional transition edge sensors result from the very small electronic heat capacity of the nanoscale detector element. In the present work, we calculate the predicted thermal response time and energy resolution. We also discuss approaches for achieving efficient optical coupling to the sub-wavelength detector element using a resonant near-IR antenna.

  16. Multiplicity Counting

    Energy Technology Data Exchange (ETDEWEB)

    Geist, William H. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-01

    This set of slides begins by giving background and a review of neutron counting; three attributes of a verification item are discussed: 240Pueff mass; α, the ratio of (α,n) neutrons to spontaneous fission neutrons; and leakage multiplication. It then takes up neutron detector systems – theory & concepts (coincidence counting, moderation, die-away time); detector systems – some important details (deadtime, corrections); introduction to multiplicity counting; multiplicity electronics and example distributions; singles, doubles, and triples from measured multiplicity distributions; and the point model: multiplicity mathematics.

  17. Optimization of injection dose based on noise-equivalent count rate with use of an anthropomorphic pelvis phantom in three-dimensional 18F-FDG PET/CT.

    Science.gov (United States)

    Inoue, Kazumasa; Kurosawa, Hideo; Tanaka, Takashi; Fukushi, Masahiro; Moriyama, Noriyuki; Fujii, Hirofumi

    2012-07-01

    The optimal injection dose for imaging of the pelvic region in 3D FDG PET tests was investigated based on the noise-equivalent count (NEC) rate with use of an anthropomorphic pelvis phantom. Count rates obtained from an anthropomorphic pelvis phantom were compared with those of pelvic images of 60 patients. The correlation between single photon count rates obtained from the pelvic regions of patients and the doses per body weight was also evaluated. The radioactivity at the maximum NEC rate was defined as an optimal injection dose, and the optimal injection dose for the body weight was evaluated. The image noise of a phantom was also investigated. Count rates obtained from an anthropomorphic pelvis phantom corresponded well with those from the human pelvis. The single photon count rate obtained from the phantom was 9.9 Mcps at the peak NEC rate. The coefficient of correlation between the single photon count rate and the dose per weight obtained from patient data was 0.830. The optimal injection doses for a patient with weighing 60 kg were estimated to be 375 MBq (6.25 MBq/kg) and 435 MBq (7.25 MBq/kg) for uptake periods of 60 and 90 min, respectively. The image noise was minimal at the peak NEC rate. We successfully estimated the optimal injection dose based on the NEC rate in the pelvic region on 3D FDG PET tests using an anthropomorphic pelvis phantom.

  18. Reticulocyte count

    Science.gov (United States)

    ... radiation therapy, or infection) Cirrhosis of the liver Anemia caused by low iron levels, or low levels of vitamin B12 or folate Chronic kidney disease Reticulocyte count may be higher during pregnancy.

  19. Analog multivariate counting analyzers

    CERN Document Server

    Nikitin, A V; Armstrong, T P

    2003-01-01

    Characterizing rates of occurrence of various features of a signal is of great importance in numerous types of physical measurements. Such signal features can be defined as certain discrete coincidence events, e.g. crossings of a signal with a given threshold, or occurrence of extrema of a certain amplitude. We describe measuring rates of such events by means of analog multivariate counting analyzers. Given a continuous scalar or multicomponent (vector) input signal, an analog counting analyzer outputs a continuous signal with the instantaneous magnitude equal to the rate of occurrence of certain coincidence events. The analog nature of the proposed analyzers allows us to reformulate many problems of the traditional counting measurements, and cast them in a form which is readily addressed by methods of differential calculus rather than by algebraic or logical means of digital signal processing. Analog counting analyzers can be easily implemented in discrete or integrated electronic circuits, do not suffer fro...

  20. Investigation of quad-energy high-rate photon counting for X-ray computed tomography using a cadmium telluride detector.

    Science.gov (United States)

    Matsukiyo, Hiroshi; Sato, Eiichi; Oda, Yasuyuki; Yamaguchi, Satoshi; Sato, Yuichi; Hagiwara, Osahiko; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya

    2017-09-10

    To obtain four kinds of tomograms at four different X-ray energy ranges simultaneously, we have constructed a quad-energy (QE) X-ray photon counter with a cadmium telluride (CdTe) detector and four sets of comparators and microcomputers (MCs). X-ray photons are detected using the CdTe detector, and the event pulses produced using amplifiers are sent to four comparators simultaneously to regulate four threshold energies of 20, 33, 50 and 65keV. Using this counter, the energy ranges are 20-33, 33-50, 50-65 and 65-100keV; the maximum energy corresponds to the tube voltage. We performed QE computed tomography (QE-CT) at a tube voltage of 100kV. Using a 0.5-mm-diam lead pinhole, four tomograms were obtained simultaneously at four energy ranges. K-edge CT using iodine and gadolinium media was carried out utilizing two energy ranges of 33-50 and 50-65keV, respectively. At a tube voltage of 100kV and a current of 60 μA, the count rate was 15.2 kilocounts per second (kcps), and the minimum count rates after penetrating objects in QE-CT were regulated to approximately 2 kcps by the tube current. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Mars sedimentary rock erosion rates constrained using crater counts, with applications to organic-matter preservation and to the global dust cycle

    Science.gov (United States)

    Kite, Edwin S.; Mayer, David P.

    2017-04-01

    Small-crater counts on Mars light-toned sedimentary rock are often inconsistent with any isochron; these data are usually plotted then ignored. We show (using an 18-HiRISE-image, > 104-crater dataset) that these non-isochron crater counts are often well-fit by a model where crater production is balanced by crater obliteration via steady exhumation. For these regions, we fit erosion rates. We infer that Mars light-toned sedimentary rocks typically erode at ∼102 nm/yr, when averaged over 10 km2 scales and 107-108 yr timescales. Crater-based erosion-rate determination is consistent with independent techniques, but can be applied to nearly all light-toned sedimentary rocks on Mars. Erosion is swift enough that radiolysis cannot destroy complex organic matter at some locations (e.g. paleolake deposits at SW Melas), but radiolysis is a severe problem at other locations (e.g. Oxia Planum). The data suggest that the relief of the Valles Marineris mounds is currently being reduced by wind erosion, and that dust production on Mars < 3 Gya greatly exceeds the modern reservoir of mobile dust.

  2. Mars sedimentary rock erosion rates constrained using crater counts, with applications to organic matter preservation and to the global dust cycle

    CERN Document Server

    Kite, Edwin S

    2016-01-01

    Small-crater counts on Mars light-toned sedimentary rock are often inconsistent with any isochron; these data are usually plotted then ignored. We show (using an 18-HiRISE-image, >10^4 crater dataset) that these non-isochron crater counts are often well-fit by a model where crater production is balanced by crater obliteration via steady exhumation. For these regions, we fit erosion rates. We infer that Mars light-toned sedimentary rocks typically erode at ~10^2 nm/yr, when averaged over 10 km^2 scales and 10^7-10^8 yr timescales. Crater-based erosion-rate determination is consistent with independent techniques, but can be applied to nearly all light-toned sedimentary rocks on Mars. Erosion is swift enough that radiolysis cannot destroy complex organic matter at some locations (e.g. paleolake deposits at SW Melas), but radiolysis is a severe problem at other locations (e.g. Oxia Planum). The data suggest that the relief of the Valles Marineris mounds is currently being reduced by wind erosion, and that dust pr...

  3. A high resolution, high frame rate detector based on a microchannel plate read out with the Medipix2 counting CMOS pixel chip.

    CERN Document Server

    Mikulec, Bettina; McPhate, J B; Tremsin, A S; Siegmund, O H W; Clark, Allan G; CERN. Geneva

    2005-01-01

    The future of ground-based optical astronomy lies with advancements in adaptive optics (AO) to overcome the limitations that the atmosphere places on high resolution imaging. A key technology for AO systems on future very large telescopes are the wavefront sensors (WFS) which detect the optical phase error and send corrections to deformable mirrors. Telescopes with >30 m diameters will require WFS detectors that have large pixel formats (512x512), low noise (<3 e-/pixel) and very high frame rates (~1 kHz). These requirements have led to the idea of a bare CMOS active pixel device (the Medipix2 chip) functioning in counting mode as an anode with noiseless readout for a microchannel plate (MCP) detector and at 1 kHz continuous frame rate. First measurement results obtained with this novel detector are presented both for UV photons and beta particles.

  4. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study.

    Science.gov (United States)

    Kamate, Wasim Ismail; Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-04-01

    Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester, third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third trimester and postpartum period. These changes

  5. Seven-Day Mortality Can Be Predicted in Medical Patients by Blood Pressure, Age, Respiratory Rate, Loss of Independence, and Peripheral Oxygen Saturation (the PARIS Score)

    DEFF Research Database (Denmark)

    Brabrand, Mikkel; Lassen, Annmarie Touborg; Knudsen, Torben

    2015-01-01

    . The outcome was defined as seven-day all-cause mortality. 76 patients (2.5%) met the endpoint in the development cohort, 57 (2.0%) in the first validation cohort, and 111 (4.3%) in the second. Systolic blood Pressure, Age, Respiratory rate, loss of Independence, and peripheral oxygen Saturation were......-day mortality of acutely admitted medical patients using routinely collected variables obtained within the first minutes after arrival. METHODS AND FINDINGS: This observational prospective cohort study used three independent cohorts at the medical admission units at a regional teaching hospital and a tertiary...... with a PARIS score ≥3, sensitivity was 62.5-74.0%, specificity 85.9-91.1%, positive predictive value 11.2-17.5%, and negative predictive value 98.3-99.3%. Patients with a score ≤1 had a low mortality (≤1%); with 2, intermediate mortality (2-5%); and ≥3, high mortality (≥10%). CONCLUSIONS: Seven-day mortality...

  6. Modeling and sensitivity analysis on the transport of aluminum oxide nanoparticles in saturated sand: effects of ionic strength, flow rate, and nanoparticle concentration.

    Science.gov (United States)

    Rahman, Tanzina; Millwater, Harry; Shipley, Heather J

    2014-11-15

    Aluminum oxide nanoparticles have been widely used in various consumer products and there are growing concerns regarding their exposure in the environment. This study deals with the modeling, sensitivity analysis and uncertainty quantification of one-dimensional transport of nano-sized (~82 nm) aluminum oxide particles in saturated sand. The transport of aluminum oxide nanoparticles was modeled using a two-kinetic-site model with a blocking function. The modeling was done at different ionic strengths, flow rates, and nanoparticle concentrations. The two sites representing fast and slow attachments along with a blocking term yielded good agreement with the experimental results from the column studies of aluminum oxide nanoparticles. The same model was used to simulate breakthrough curves under different conditions using experimental data and calculated 95% confidence bounds of the generated breakthroughs. The sensitivity analysis results showed that slow attachment was the most sensitive parameter for high influent concentrations (e.g. 150 mg/L Al2O3) and the maximum solid phase retention capacity (related to blocking function) was the most sensitive parameter for low concentrations (e.g. 50 mg/L Al2O3).

  7. Asthma and myocardial infarction inpatient hospitalization and emergency room visit counts and rates by county, year and month of admission, age group, race/ethnicity and gender of California residents, 2000-2009.

    Data.gov (United States)

    California Environmental Health Tracking Program — This dataset contains case counts, rates, and confidence intervals of asthma (ICD9-CM 493.0-493.9) and myocardial infarction (ICD9-CM 410) inpatient hospitalizations...

  8. CD4 count and viral load specific rates of AIDS, non-AIDS and deaths according to current antiretroviral use

    Directory of Open Access Journals (Sweden)

    A Mocroft

    2012-11-01

    Full Text Available Background CD4 and viral loads are used in clinical trials as surrogate endpoints for assessing efficacy of newly available antiretrovirals. If antiretrovirals act through other pathways or negatively affect the risk of disease this would not be identified prior to licensing. The aims of this study were to investigate the CD4 and viral load specific rates of fatal and non-fatal AIDS and non-AIDS events according to current antiretrovirals. Methods Poisson regression was used to compare overall events (fatal or non-fatal AIDS, non-AIDS or death, AIDS events (fatal and non-fatal or non-AIDS events (fatal or non-fatal for specific nucleoside pairs and third drugs used with>1000 person-years of follow-up (PYFU after January 1st 2001. Results 9801 patients were included. The median baseline date was January 2004 (interquartile range [IQR] January 2001–February 2007, age was 40.4 (IQR 34.6–47.3 years, and time since starting cART was 3.3 (IQR 0.9–5.1 years. At baseline, the median nadir CD4 was 162 (IQR 71–257/mm3, baseline CD4 was 390 (IQR 249–571/mm3, viral load was 1.9 (IQR 1.7–3.3 log10copies/ml and 2961 (30.2% had a prior AIDS diagnosis and 6.4 years prior to baseline. During 42372.5 PYFU, 1203 (437 AIDS and 766 non-AIDS events occurred. The overall event rate was 2.8 per 100 PYFU (95% confidence interval [CI] 2.7–3.0, of AIDS events was 1.0 (95% CI 0.9–1.1 and of non-AIDS events was 1.8 (95% CI 1.7–1.9. Of the AIDS events, 53 (12.1%were fatal as were 239 (31.2% of the non-AIDS events. After adjustment, there was weak evidence of a difference in the overall events rates between nucleoside pairs (global p-value=0.084, and third drugs (global p-value=0.031. Compared to zidovudine/lamivudine, patients taking abacavir/lamivudine (adjusted incidence rate ratio [aIRR] 1.22; 95% CI 0.99–1.49 and abacavir plus one other nucleoside (aIRR 1.51; 95% CI 1.14–2.02 had an increased incidence of overall events. Comparing the third drugs

  9. A yearly spraying of olive mill wastewater on agricultural soil over six successive years: impact of different application rates on olive production, phenolic compounds, phytotoxicity and microbial counts.

    Science.gov (United States)

    Magdich, Salwa; Jarboui, Raja; Rouina, Béchir Ben; Boukhris, Makki; Ammar, Emna

    2012-07-15

    Olive mill wastewater (OMW) spraying effects onto olive-tree fields were investigated. Three OMW levels (50, 100 and 200 m(3)ha(-1)year(-1)) were applied over six successive years. Olive-crop yields, phenolic compounds progress, phytotoxicity and microbial counts were studied at different soil depths. Olive yield showed improvements with OMW level applied. Soil polyphenolic content increased progressively in relation to OMW levels in all the investigated layers. However, no significant difference was noted in lowest treatment rate compared to the control field. In the soil upper-layers (0-40 cm), five phenolic compounds were identified over six consecutive years of OMW-spraying. In all the soil-layers, the radish germination index exceeded 85%. However, tomato germination test values decreased with the applied OMW amount. For all treatments, microbial counts increased with OMW quantities and spraying frequency. Matrix correlation showed a strong relationship between soil polyphenol content and microorganisms, and a negative one to tomato germination index.

  10. Neutron counting with cameras

    Energy Technology Data Exchange (ETDEWEB)

    Van Esch, Patrick; Crisanti, Marta; Mutti, Paolo [Institut Laue Langevin, Grenoble (France)

    2015-07-01

    A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involved are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)

  11. Venous oxygen saturation.

    Science.gov (United States)

    Hartog, Christiane; Bloos, Frank

    2014-12-01

    Early detection and rapid treatment of tissue hypoxia are important goals. Venous oxygen saturation is an indirect index of global oxygen supply-to-demand ratio. Central venous oxygen saturation (ScvO2) measurement has become a surrogate for mixed venous oxygen saturation (SvO2). ScvO2 is measured by a catheter placed in the superior vena cava. After results from a single-center study suggested that maintaining ScvO2 values >70% might improve survival rates in septic patients, international practice guidelines included this target in a bundle strategy to treat early sepsis. However, a recent multicenter study with >1500 patients found that the use of central hemodynamic and ScvO2 monitoring did not improve long-term survival when compared to the clinical assessment of the adequacy of circulation. It seems that if sepsis is recognized early, a rapid initiation of antibiotics and adequate fluid resuscitation are more important than measuring venous oxygen saturation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Understanding Blood Counts

    Science.gov (United States)

    ... Lab and Imaging Tests Understanding Blood Counts Understanding Blood Counts Understanding Blood Counts SHARE: Print Glossary Blood cell counts give ... your blood that's occupied by red cells. Normal Blood Counts Normal blood counts fall within a range ...

  13. White Blood Cell Count

    Science.gov (United States)

    ... limited. Home Visit Global Sites Search Help? White Blood Cell Count Share this page: Was this page helpful? ... Count; Leukocyte Count; White Count Formal name: White Blood Cell Count Related tests: Complete Blood Count , Blood Smear , ...

  14. A user configurable data acquisition and signal processing system for high-rate, high channel count applications

    Energy Technology Data Exchange (ETDEWEB)

    Salim, Arwa, E-mail: arwa.salim@eee.strath.ac.uk [University of Strathclyde, Scotland (United Kingdom); Crockett, Louise [University of Strathclyde, Scotland (United Kingdom); McLean, John; Milne, Peter [D-TACQ Solutions, Scotland (United Kingdom)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer The development of a new digital signal processing platform is described. Black-Right-Pointing-Pointer The system will allow users to configure the real-time signal processing through software routines. Black-Right-Pointing-Pointer The architecture of the DRUID system and signal processing elements is described. Black-Right-Pointing-Pointer A prototype of the DRUID system has been developed for the digital chopper-integrator. Black-Right-Pointing-Pointer The results of acquisition on 96 channels at 500 kSamples/s per channel are presented. - Abstract: Real-time signal processing in plasma fusion experiments is required for control and for data reduction as plasma pulse times grow longer. The development time and cost for these high-rate, multichannel signal processing systems can be significant. This paper proposes a new digital signal processing (DSP) platform for the data acquisition system that will allow users to easily customize real-time signal processing systems to meet their individual requirements. The D-TACQ reconfigurable user in-line DSP (DRUID) system carries out the signal processing tasks in hardware co-processors (CPs) implemented in an FPGA, with an embedded microprocessor ({mu}P) for control. In the fully developed platform, users will be able to choose co-processors from a library and configure programmable parameters through the {mu}P to meet their requirements. The DRUID system is implemented on a Spartan 6 FPGA, on the new rear transition module (RTM-T), a field upgrade to existing D-TACQ digitizers. As proof of concept, a multiply-accumulate (MAC) co-processor has been developed, which can be configured as a digital chopper-integrator for long pulse magnetic fusion devices. The DRUID platform allows users to set options for the integrator, such as the number of masking samples. Results from the digital integrator are presented for a data acquisition system with 96 channels simultaneously acquiring data

  15. Counting Penguins.

    Science.gov (United States)

    Perry, Mike; Kader, Gary

    1998-01-01

    Presents an activity on the simplification of penguin counting by employing the basic ideas and principles of sampling to teach students to understand and recognize its role in statistical claims. Emphasizes estimation, data analysis and interpretation, and central limit theorem. Includes a list of items for classroom discussion. (ASK)

  16. Counting Populations

    Science.gov (United States)

    Damonte, Kathleen

    2004-01-01

    Scientists use sampling to get an estimate of things they cannot easily count. A population is made up of all the organisms of one species living together in one place at the same time. All of the people living together in one town are considered a population. All of the grasshoppers living in a field are a population. Scientists keep track of the…

  17. Gamma-ray spectroscopy at MHz counting rates with a compact LaBr{sub 3} detector and silicon photomultipliers for fusion plasma applications

    Energy Technology Data Exchange (ETDEWEB)

    Nocente, M., E-mail: massimo.nocente@mib.infn.it [EUROfusion Consortium, JET, Culham Science Centre, Abingdon (United Kingdom); Dipartimento di Fisica, Università di Milano-Bicocca, Milano (Italy); Istituto di Fisica del Plasma “Piero Caldirola,” Milano (Italy); Rigamonti, D.; Croci, G.; Gorini, G. [Dipartimento di Fisica, Università di Milano-Bicocca, Milano (Italy); Istituto di Fisica del Plasma “Piero Caldirola,” Milano (Italy); Perseo, V. [Dipartimento di Fisica, Università di Milano-Bicocca, Milano (Italy); Tardocchi, M.; Cremona, A.; Muraro, A. [Istituto di Fisica del Plasma “Piero Caldirola,” Milano (Italy); Boltruczyk, G.; Broslawski, A.; Gosk, M.; Korolczuk, S.; Zychor, I. [Narodowe Centrum Badan Jadrowych (NCBJ), Otwock-Swierk (Poland); Kiptily, V. [Culham Centre for Fusion Energy, Culham (United Kingdom); Mazzocco, M.; Strano, E. [Dipartimento di Fisica, Istituto Nazionale di Fisica Nucleare, Padova (Italy); Collaboration: EUROfusion Consortium, JET, Culham Science Centre, Abingdon (United Kingdom)

    2016-11-15

    Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr{sub 3} scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

  18. Gamma-ray spectroscopy at MHz counting rates with a compact LaBr3 detector and silicon photomultipliers for fusion plasma applications.

    Science.gov (United States)

    Nocente, M; Rigamonti, D; Perseo, V; Tardocchi, M; Boltruczyk, G; Broslawski, A; Cremona, A; Croci, G; Gosk, M; Kiptily, V; Korolczuk, S; Mazzocco, M; Muraro, A; Strano, E; Zychor, I; Gorini, G

    2016-11-01

    Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr3 scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

  19. Gamma-ray spectroscopy at MHz counting rates with a compact LaBr3 detector and silicon photomultipliers for fusion plasma applications

    Science.gov (United States)

    Nocente, M.; Rigamonti, D.; Perseo, V.; Tardocchi, M.; Boltruczyk, G.; Broslawski, A.; Cremona, A.; Croci, G.; Gosk, M.; Kiptily, V.; Korolczuk, S.; Mazzocco, M.; Muraro, A.; Strano, E.; Zychor, I.; Gorini, G.

    2016-11-01

    Gamma-ray spectroscopy measurements at MHz counting rates have been carried out, for the first time, with a compact spectrometer based on a LaBr3 scintillator and silicon photomultipliers. The instrument, which is also insensitive to magnetic fields, has been developed in view of the upgrade of the gamma-ray camera diagnostic for α particle measurements in deuterium-tritium plasmas of the Joint European Torus. Spectra were measured up to 2.9 MHz with a projected energy resolution of 3%-4% in the 3-5 MeV range, of interest for fast ion physics studies in fusion plasmas. The results reported here pave the way to first time measurements of the confined α particle profile in high power plasmas of the next deuterium-tritium campaign at the Joint European Torus.

  20. Count rate studies of a box-shaped PET breast imaging system comprised of position sensitive avalanche photodiodes utilizing monte carlo simulation.

    Science.gov (United States)

    Foudray, Angela M K; Habte, Frezghi; Chinn, Garry; Zhang, Jin; Levin, Craig S

    2006-01-01

    We are investigating a high-sensitivity, high-resolution positron emission tomography (PET) system for clinical use in the detection, diagnosis and staging of breast cancer. Using conventional figures of merit, design parameters were evaluated for count rate performance, module dead time, and construction complexity. The detector system modeled comprises extremely thin position-sensitive avalanche photodiodes coupled to lutetium oxy-orthosilicate scintillation crystals. Previous investigations of detector geometries with Monte Carlo indicated that one of the largest impacts on sensitivity is local scintillation crystal density when considering systems having the same average scintillation crystal densities (same crystal packing fraction and system solid-angle coverage). Our results show the system has very good scatter and randoms rejection at clinical activity ranges ( approximately 200 muCi).

  1. Determination of total Pu content in a Spent Fuel Assembly by Measuring Passive Neutron Count rate and Multiplication with the Differential Die-Away Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Henzl, Vladimir [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Swinhoe, Martyn T. [Los Alamos National Laboratory; Tobin, Stephen J. [Los Alamos National Laboratory

    2012-07-18

    A key objective of the Next Generation Safeguards Initiative (NGSI) is to evaluate and develop non-destructive assay (NDA) techniques to determine the elemental plutonium content in a commercial-grade nuclear spent fuel assembly (SFA) [1]. Within this framework, we investigate by simulation a novel analytical approach based on combined information from passive measurement of the total neutron count rate of a SFA and its multiplication determined by the active interrogation using an instrument based on a Differential Die-Away technique (DDA). We use detailed MCNPX simulations across an extensive set of SFA characteristics to establish the approach and demonstrate its robustness. It is predicted that Pu content can be determined by the proposed method to a few %.

  2. Gamma-gamma coincidence performance of LaBr3:Ce scintillation detectors vs HPGe detectors in high count-rate scenarios.

    Science.gov (United States)

    Drescher, A; Yoho, M; Landsberger, S; Durbin, M; Biegalski, S; Meier, D; Schwantes, J

    2017-04-01

    A radiation detection system consisting of two cerium doped lanthanum bromide (LaBr3:Ce) scintillation detectors in a gamma-gamma coincidence configuration has been used to demonstrate the advantages that coincident detection provides relative to a single detector, and the advantages that LaBr3:Ce detectors provide relative to high purity germanium (HPGe) detectors. Signal to noise ratios of select photopeak pairs for these detectors have been compared to high-purity germanium (HPGe) detectors in both single and coincident detector configurations in order to quantify the performance of each detector configuration. The efficiency and energy resolution of LaBr3:Ce detectors have been determined and compared to HPGe detectors. Coincident gamma-ray pairs from the radionuclides (152)Eu and (133)Ba have been identified in a sample that is dominated by (137)Cs. Gamma-gamma coincidence successfully reduced the Compton continuum from the large (137)Cs peak, revealed several coincident gamma energies characteristic of these nuclides, and improved the signal-to-noise ratio relative to single detector measurements. LaBr3:Ce detectors performed at count rates multiple times higher than can be achieved with HPGe detectors. The standard background spectrum consisting of peaks associated with transitions within the LaBr3:Ce crystal has also been significantly reduced. It is shown that LaBr3:Ce detectors have the unique capability to perform gamma-gamma coincidence measurements in very high count rate scenarios, which can potentially benefit nuclear safeguards in situ measurements of spent nuclear fuel. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Saturated fat (image)

    Science.gov (United States)

    Saturated fat can raise blood cholesterol and can put you at risk for heart disease and stroke. You ... or limit any foods that are high in saturated fat. Sources of saturated fat include whole-milk dairy ...

  4. Star-formation rates from young-star counts and the structure of the ISM across the NGC346/N66 complex in the SMC

    CERN Document Server

    Hony, S; Galliano, F; Galametz, M; Cormier, D; Chen, C -H R; Dib, S; Hughes, A; Klessen, R S; Roman-Duval, J; Smith, L; Bernard, J -P; Bot, C; Carlson, L; Gordon, K; Indebetouw, R; Lebouteiller, V; Lee, M -Y; Madden, S C; Meixner, M; Oliveira, J; Rubio, M; Sauvage, M; Wu, R

    2015-01-01

    The rate at which interstellar gas is converted into stars, and its dependence on environment, is one of the pillars on which our understanding of the visible Universe is build. We present a comparison of the surface density of young stars (Sigma_*) and dust surface density (Sigma_d) across NGC346 (N66) in 115 independent pixels of 6x6 pc^2. We find a correlation between Sigma_* and Sigma_d with a considerable scatter. A power law fit to the data yields a steep relation with an exponent of 2.6+-0.2. We convert Sigma_d to gas surface density (Sigma_g) and Sigma_* to star formation rate (SFR) surface densities (Sigma_SFR), using simple assumptions for the gas-to-dust mass ratio and the duration of star formation. The derived total SFR (4+-1 10^-3 M_sun/yr) is consistent with SFR estimated from the Ha emission integrated over the Ha nebula. On small scales the Sigma_SFR derived using Ha systematically underestimates the count-based Sigma_SFR, by up to a factor of 10. This is due to ionizing photons escaping the ...

  5. Star formation rates from young-star counts and the structure of the ISM across the NGC 346/N66 complex in the SMC

    Science.gov (United States)

    Hony, S.; Gouliermis, D. A.; Galliano, F.; Galametz, M.; Cormier, D.; Chen, C.-H. R.; Dib, S.; Hughes, A.; Klessen, R. S.; Roman-Duval, J.; Smith, L.; Bernard, J.-P.; Bot, C.; Carlson, L.; Gordon, K.; Indebetouw, R.; Lebouteiller, V.; Lee, M.-Y.; Madden, S. C.; Meixner, M.; Oliveira, J.; Rubio, M.; Sauvage, M.; Wu, R.

    2015-04-01

    The rate at which interstellar gas is converted into stars, and its dependence on environment, is one of the pillars on which our understanding of the visible Universe is build. We present a comparison of the surface density of young stars (Σ⋆) and dust surface density (Σdust) across NGC 346 (N66) in 115 independent pixels of 6 × 6 pc2. We find a correlation between Σ⋆ and Σdust with a considerable scatter. A power-law fit to the data yields a steep relation with an exponent of 2.6 ± 0.2. We convert Σdust to gas surface density (Σgas) and Σ⋆ to star formation rate (SFR) surface densities (ΣSFR), using simple assumptions for the gas-to-dust mass ratio and the duration of star formation. The derived total SFR (4 ± 1×10-3 M⊙ yr-1) is consistent with SFR estimated from the Hα emission integrated over the Hα nebula. On small scales the ΣSFR derived using Hα systematically underestimates the count-based ΣSFR, by up to a factor of 10. This is due to ionizing photons escaping the area, where the stars are counted. We find that individual 36 pc2 pixels fall systematically above integrated disc galaxies in the Schmidt-Kennicutt diagram by on average a factor of ˜7. The NGC 346 average SFR over a larger area (90 pc radius) lies closer to the relation but remains high by a factor of ˜3. The fraction of the total mass (gas plus young stars) locked in young stars is systematically high (˜10 per cent) within the central 15 pc and systematically lower outside (2 per cent), which we interpret as variations in star formation efficiency. The inner 15 pc is dominated by young stars belonging to a centrally condensed cluster, while the outer parts are dominated by a dispersed population. Therefore, the observed trend could reflect a change of star formation efficiency between clustered and non-clustered star formation.

  6. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  7. Reticulocyte Count Test

    Science.gov (United States)

    ... may be ordered when: CBC results show a decreased RBC count and/or a decreased hemoglobin and hematocrit A healthcare practitioner wants to ... and hematocrit, to help determine the degree and rate of overproduction of RBCs ... during pregnancy . Newborns have a higher percentage of reticulocytes, but ...

  8. Photon counting digital holography

    Science.gov (United States)

    Demoli, Nazif; Skenderović, Hrvoje; Stipčević, Mario; Pavičić, Mladen

    2016-05-01

    Digital holography uses electronic sensors for hologram recording and numerical method for hologram reconstruction enabling thus the development of advanced holography applications. However, in some cases, the useful information is concealed in a very wide dynamic range of illumination intensities and successful recording requires an appropriate dynamic range of the sensor. An effective solution to this problem is the use of a photon-counting detector. Such detectors possess counting rates of the order of tens to hundreds of millions counts per second, but conditions of recording holograms have to be investigated in greater detail. Here, we summarize our main findings on this problem. First, conditions for optimum recording of digital holograms for detecting a signal significantly below detector's noise are analyzed in terms of the most important holographic measures. Second, for time-averaged digital holograms, optimum recordings were investigated for exposures shorter than the vibration cycle. In both cases, these conditions are studied by simulations and experiments.

  9. Comparison of membrane filtration rates and hydrophobic grid membrane filter coliform and Escherichia coli counts in food suspensions using paddle-type and pulsifier sample preparation procedures.

    Science.gov (United States)

    Sharpe, A N; Hearn, E M; Kovacs-Nolan, J

    2000-01-01

    Food suspensions prepared by Pulsifier contained less debris and filtered 1.3x to 12x faster through hydrophobic grid membrane filters (HGMFs) than those prepared by Stomacher 400. Coliform and Escherichia coli counts made by an HGMF method yielded 84 and 36 paired samples, respectively, positive by both suspending methods. Overall counts of pulsificates and stomachates did not differ significantly for either analysis, though coliform counts by Pulsifier were significantly higher in mushrooms and significantly lower in ground pork (P = 0.05). Regression equations for log10 counts of coliform and E. coli by Pulsifier and Stomacher were: Pulsifier = 0.12 + 0.97 x Stomacher, and Pulsifier = 0.01 + 1.01 x Stomacher, respectively.

  10. Graphical procedure for comparing thermal death of Bacillus stearothermophilus spores in saturated and superheated steam.

    Science.gov (United States)

    SHULL, J J; ERNST, R R

    1962-09-01

    The thermal death curve of dried spores of Bacillus stearothermophilus in saturated steam was characterized by three phases: (i) a sharp initial rise in viable count; (ii) a low rate of death which gradually increased; and (iii) logarithmic death at maximal rate. The first phase was a reflection of inadequate heat activation of the spore population. The second and third phases represented the characteristic thermal death curve of the spores in saturated steam. A jacketed steam sterilizer, equipped with a system for initial evacuation of the chamber, was examined for superheat during normal operation. Measurements of spore inactivation and temperature revealed superheat in surface layers of fabrics being processed in steam at 121 C. The high temperature of the fabric surfaces was attributed to absorption of excess heat energy from superheated steam. The superheated steam was produced at the beginning of the normal sterilizing cycle by transfer of heat from the steam-heated jacket to saturated steam entering the vessel.

  11. 饱和冻结粉土在常应变速率下的单轴抗压强度%Uniaxial Compressive Strength of the Saturated Frozen Silt at Constant Strain Rates

    Institute of Scientific and Technical Information of China (English)

    李海鹏; 朱元林; 潘卫东

    2002-01-01

    Uniaxial compressive strength tests were conducted on the saturated frozen Lanzhou silt (loess) at various constant strain rates and at various constant temperatures. It is concluded from the test results that: the compressive strength (σ f) is very sensitive to temperature (θ) and increases with the temperature decreasing as a power law. Compressive strength is sensitive to strain rate () and increases with strain rates increasing within a certain range of strain rates as a power law. Compressive strength decreases when time to failure (tf) increases, also following a power law. Finally, Compressive strength of frozen silt with higher dry density (γd) is higher than that of frozen silt with lower dry density. The difference between them is mainly influenced by strain rate.

  12. Research of Paste New Definition from the Viewpoint of Saturation Ratio and Bleeding Rate%从饱和率和泌水率角度探讨膏体新定义

    Institute of Scientific and Technical Information of China (English)

    王洪江; 王勇; 吴爱祥; 翟永刚; 焦华喆

    2011-01-01

    目前膏体定义不够清晰,影响到膏体充填技术的发展,有必要控讨简单实用的膏体新定义。借鉴土力学中饱和度以及流态化混凝土中泌水率这两个概念,提出了以集料饱和率与泌水率为主要指标的膏体定义体系。通过理论分析计算,浆体饱和率在101.5%~105.3%之间,泌水率在1.5%~5%之间,即构成合格的膏体。对会泽膏体物料进行实测分析,当膏体质量分数范围在80.5%~81.4%时,饱和率计算值为101.5%~105.3%,现场泌水率监测值为3.1%~4.2%。膏体新定义能够完全定量化,简化了膏体检验方法,具有较高的可靠性。%The definition of paste is not clear at present,affecting the development of paste filling technologies,which renders it necessary to explore a new paste definition that is simple and practical. Learning from the saturation of soil mechanics and the fluidization of concrete bleeding rate, we have proposed the definition of the paste system which contains the two key indicators, the saturation rate and the aggregate rate of bleeding. Through theoretical analysis and calculation, a qualified paste consists of the slurry saturated rate of 101. 5%~105. 3% and bleeding rate of 1. 5%~5%. To measure and analyze Hui Ze paste materials, when the paste concentration range is 80. 5%~81. 4% , the saturation rate of the calculated value is 101. 5%~105. 3%, on-site monitoring of the bleeding rate is 3. 1%~4. 2%. The new paste definition can fully quantitative, and simplify the paste test method with high reliability.

  13. Quantitative chemical exchange saturation transfer (qCEST) MRI - omega plot analysis of RF-spillover-corrected inverse CEST ratio asymmetry for simultaneous determination of labile proton ratio and exchange rate.

    Science.gov (United States)

    Wu, Renhua; Xiao, Gang; Zhou, Iris Yuwen; Ran, Chongzhao; Sun, Phillip Zhe

    2015-03-01

    Chemical exchange saturation transfer (CEST) MRI is sensitive to labile proton concentration and exchange rate, thus allowing measurement of dilute CEST agent and microenvironmental properties. However, CEST measurement depends not only on the CEST agent properties but also on the experimental conditions. Quantitative CEST (qCEST) analysis has been proposed to address the limitation of the commonly used simplistic CEST-weighted calculation. Recent research has shown that the concomitant direct RF saturation (spillover) effect can be corrected using an inverse CEST ratio calculation. We postulated that a simplified qCEST analysis is feasible with omega plot analysis of the inverse CEST asymmetry calculation. Specifically, simulations showed that the numerically derived labile proton ratio and exchange rate were in good agreement with input values. In addition, the qCEST analysis was confirmed experimentally in a phantom with concurrent variation in CEST agent concentration and pH. Also, we demonstrated that the derived labile proton ratio increased linearly with creatine concentration (P exchange rate followed a dominantly base-catalyzed exchange relationship (P exchange rate in a relatively complex in vitro CEST system.

  14. CD4 cell count and viral load-specific rates of AIDS, non-AIDS and deaths according to current antiretroviral use

    NARCIS (Netherlands)

    Mocroft, A.; Phillips, A.N.; Gatell, J.; Horban, A.; Ledergerber, B.; Zilmer, K.; Jevtovic, D.; Maltez, F.; Podlekareva, D.; Lundgren, J.D.; Burger, D.M.

    2013-01-01

    BACKGROUND: CD4 cell count and viral loads are used in clinical trials as surrogate endpoints for assessing efficacy of newly available antiretrovirals. If antiretrovirals act through other pathways or increase the risk of disease this would not be identified prior to licensing. The aim of this stud

  15. A general unified non-equilibrium model for predicting saturated and subcooled critical two-phase flow rates through short and long tubes

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, D.W.H. [Univ. of British Columbia (Canada); Abdelmessih, A.H. [Univ. of Toronto, Ontario (Canada)

    1995-09-01

    A general unified model is developed to predict one-component critical two-phase pipe flow. Modelling of the two-phase flow is accomplished by describing the evolution of the flow between the location of flashing inception and the exit (critical) plane. The model approximates the nonequilibrium phase change process via thermodynamic equilibrium paths. Included are the relative effects of varying the location of flashing inception, pipe geometry, fluid properties and length to diameter ratio. The model predicts that a range of critical mass fluxes exist and is bound by a maximum and minimum value for a given thermodynamic state. This range is more pronounced at lower subcooled stagnation states and can be attributed to the variation in the location of flashing inception. The model is based on the results of an experimental study of the critical two-phase flow of saturated and subcooled water through long tubes. In that study, the location of flashing inception was accurately controlled and adjusted through the use of a new device. The data obtained revealed that for fixed stagnation conditions, the maximum critical mass flux occurred with flashing inception located near the pipe exit; while minimum critical mass fluxes occurred with the flashing front located further upstream. Available data since 1970 for both short and long tubes over a wide range of conditions are compared with the model predictions. This includes test section L/D ratios from 25 to 300 and covers a temperature and pressure range of 110 to 280{degrees}C and 0.16 to 6.9 MPa. respectively. The predicted maximum and minimum critical mass fluxes show an excellent agreement with the range observed in the experimental data.

  16. Saturated Switching Systems

    CERN Document Server

    Benzaouia, Abdellah

    2012-01-01

    Saturated Switching Systems treats the problem of actuator saturation, inherent in all dynamical systems by using two approaches: positive invariance in which the controller is designed to work within a region of non-saturating linear behaviour; and saturation technique which allows saturation but guarantees asymptotic stability. The results obtained are extended from the linear systems in which they were first developed to switching systems with uncertainties, 2D switching systems, switching systems with Markovian jumping and switching systems of the Takagi-Sugeno type. The text represents a thoroughly referenced distillation of results obtained in this field during the last decade. The selected tool for analysis and design of stabilizing controllers is based on multiple Lyapunov functions and linear matrix inequalities. All the results are illustrated with numerical examples and figures many of them being modelled using MATLAB®. Saturated Switching Systems will be of interest to academic researchers in con...

  17. Trends in CD4 Count Testing, Retention in Pre-ART Care, and ART Initiation Rates over the First Decade of Expansion of HIV Services in Haiti

    Science.gov (United States)

    Koenig, Serena P.; Bernard, Daphne; Dévieux, Jessy G.; Atwood, Sidney; McNairy, Margaret L.; Severe, Patrice; Marcelin, Adias; Julma, Pierrot; Apollon, Alexandra; Pape, Jean W.

    2016-01-01

    Background High attrition during the period from HIV testing to antiretroviral therapy (ART) initiation is widely reported. Though treatment guidelines have changed to broaden ART eligibility and services have been widely expanded over the past decade, data on the temporal trends in pre-ART outcomes are limited; such data would be useful to guide future policy decisions. Methods We evaluated temporal trends and predictors of retention for each step from HIV testing to ART initiation over the past decade at the GHESKIO clinic in Port-au-Prince Haiti. The 24,925 patients >17 years of age who received a positive HIV test at GHESKIO from March 1, 2003 to February 28, 2013 were included. Patients were followed until they remained in pre-ART care for one year or initiated ART. Results 24,925 patients (61% female, median age 35 years) were included, and 15,008 (60%) had blood drawn for CD4 count within 12 months of HIV testing; the trend increased over time from 36% in Year 1 to 78% in Year 10 (p500 cells/mm3, respectively. The trend increased over time for each CD4 strata, and in Year 10, 94%, 95%, 79%, and 74% were retained in pre-ART care or initiated ART for each CD4 strata. Predictors of pre-ART attrition included male gender, low income, and low educational status. Older age and tuberculosis (TB) at HIV testing were associated with retention in care. Conclusions The proportion of patients completing assessments for ART eligibility, remaining in pre-ART care, and initiating ART have increased over the last decade across all CD4 count strata, particularly among patients with CD4 count ≤350 cells/mm3. However, additional retention efforts are needed for patients with higher CD4 counts. PMID:26901795

  18. Trends in CD4 Count Testing, Retention in Pre-ART Care, and ART Initiation Rates over the First Decade of Expansion of HIV Services in Haiti.

    Directory of Open Access Journals (Sweden)

    Serena P Koenig

    Full Text Available High attrition during the period from HIV testing to antiretroviral therapy (ART initiation is widely reported. Though treatment guidelines have changed to broaden ART eligibility and services have been widely expanded over the past decade, data on the temporal trends in pre-ART outcomes are limited; such data would be useful to guide future policy decisions.We evaluated temporal trends and predictors of retention for each step from HIV testing to ART initiation over the past decade at the GHESKIO clinic in Port-au-Prince Haiti. The 24,925 patients >17 years of age who received a positive HIV test at GHESKIO from March 1, 2003 to February 28, 2013 were included. Patients were followed until they remained in pre-ART care for one year or initiated ART.24,925 patients (61% female, median age 35 years were included, and 15,008 (60% had blood drawn for CD4 count within 12 months of HIV testing; the trend increased over time from 36% in Year 1 to 78% in Year 10 (p500 cells/mm3, respectively. The trend increased over time for each CD4 strata, and in Year 10, 94%, 95%, 79%, and 74% were retained in pre-ART care or initiated ART for each CD4 strata. Predictors of pre-ART attrition included male gender, low income, and low educational status. Older age and tuberculosis (TB at HIV testing were associated with retention in care.The proportion of patients completing assessments for ART eligibility, remaining in pre-ART care, and initiating ART have increased over the last decade across all CD4 count strata, particularly among patients with CD4 count ≤350 cells/mm3. However, additional retention efforts are needed for patients with higher CD4 counts.

  19. Application of Flow Cytometer in CHO Cell Counting and Cell Survival Rate Calculation%应用流式细胞仪进行CHO细胞计数及存活率计算

    Institute of Scientific and Technical Information of China (English)

    高茜; 管莹; 米其利; 李雪梅; 缪明明; 夭建华

    2012-01-01

    Using CHO bioengineering cell as target, application of flow cytometer in cell counting and cell survival rate calculation was explored in this paper. The results showed that cell counting and survival rate calculation could be accurate by the flow cytometer through the set of three parameters SS,EV, and FL3. Compared with blood cell counting plate method, flow cytometer method was more efficient and stable with faster operation and lower SD value. Therefore, to improve the production efficiency and toxicological evaluation reliability, flow cytometer method was recommend to be applied in large scale experiments for cell counting and survival rate calculation.%以CHO生物工程细胞为对象,探索了流式细胞仪在细胞计数和细胞存活率计算方面的应用.通过设定侧向角散射SS、电子体积EV及荧光强度FL3等3个参数,编制CHO细胞计数程序,再应用流式细胞仪进行细胞计数和存活率计算,其结果与血球计数板法基本一致,但操作更迅速、SD值更低,说明流式细胞仪法较血球计数板法更高效稳定.流式细胞仪法提高了生物工程的生产效率和毒理学评价的准确性,可应用于大规模细胞实验中.

  20. Saturated Zone Colloid Transport

    Energy Technology Data Exchange (ETDEWEB)

    H. S. Viswanathan

    2004-10-07

    This scientific analysis provides retardation factors for colloids transporting in the saturated zone (SZ) and the unsaturated zone (UZ). These retardation factors represent the reversible chemical and physical filtration of colloids in the SZ. The value of the colloid retardation factor, R{sub col} is dependent on several factors, such as colloid size, colloid type, and geochemical conditions (e.g., pH, Eh, and ionic strength). These factors are folded into the distributions of R{sub col} that have been developed from field and experimental data collected under varying geochemical conditions with different colloid types and sizes. Attachment rate constants, k{sub att}, and detachment rate constants, k{sub det}, of colloids to the fracture surface have been measured for the fractured volcanics, and separate R{sub col} uncertainty distributions have been developed for attachment and detachment to clastic material and mineral grains in the alluvium. Radionuclides such as plutonium and americium sorb mostly (90 to 99 percent) irreversibly to colloids (BSC 2004 [DIRS 170025], Section 6.3.3.2). The colloid retardation factors developed in this analysis are needed to simulate the transport of radionuclides that are irreversibly sorbed onto colloids; this transport is discussed in the model report ''Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]). Although it is not exclusive to any particular radionuclide release scenario, this scientific analysis especially addresses those scenarios pertaining to evidence from waste-degradation experiments, which indicate that plutonium and americium may be irreversibly attached to colloids for the time scales of interest. A section of this report will also discuss the validity of using microspheres as analogs to colloids in some of the lab and field experiments used to obtain the colloid retardation factors. In addition, a small fraction of colloids travels with the groundwater without any significant

  1. Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kurz, Christopher, E-mail: Christopher.Kurz@physik.uni-muenchen.de; Bauer, Julia [Heidelberg Ion-Beam Therapy Center and Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120 (Germany); Conti, Maurizio; Guérin, Laura; Eriksson, Lars [Siemens Healthcare Molecular Imaging, Knoxville, Tennessee 37932 (United States); Parodi, Katia [Heidelberg Ion-Beam Therapy Center and Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg 69120, Germany and Department of Experimental Physics – Medical Physics, Ludwig-Maximilians-University, Munich 85748 (Germany)

    2015-07-15

    Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended

  2. Saturating Sperner families

    CERN Document Server

    Gerbner, Dániel; Lemons, Nathan; Pálvölgyi, Dömötör; Palmer, Cory; Patkós, Balázs

    2011-01-01

    A family $\\cF \\subseteq 2^{[n]}$ saturates the monotone decreasing property $\\cP$ if $\\cF$ satisfies $\\cP$ and one cannot add any set to $\\cF$ such that property $\\cP$ is still satisfied by the resulting family. We address the problem of finding the minimum size of a family saturating the $k$-Sperner property and the minimum size of a family that saturates the Sperner property and that consists only of $l$-sets and $(l+1)$-sets.

  3. A Pixel Readout Chip in 40 nm CMOS Process for High Count Rate Imaging Systems with Minimization of Charge Sharing Effects

    Energy Technology Data Exchange (ETDEWEB)

    Maj, Piotr; Grybos, P.; Szczgiel, R.; Kmon, P.; Drozd, A.; Deptuch, G.

    2013-11-07

    We present a prototype chip in 40 nm CMOS technology for readout of hybrid pixel detector. The prototype chip has a matrix of 18x24 pixels with a pixel pitch of 100 m. It can operate both in single photon counting (SPC) mode and in C8P1 mode. In SPC the measured ENC is 84 e rms (for the peaking time of 48 ns), while the effective offset spread is below 2 mV rms. In the C8P1 mode the chip reconstructs full charge deposited in the detector, even in the case of charge sharing, and it identifies a pixel with the largest charge deposition. The chip architecture and preliminary measurements are reported.

  4. Comparison the effects of shallow and deep endotracheal tube suctioning on respiratory rate, arterial blood oxygen saturation and number of suctioning in patients hospitalized in the intensive care unit

    DEFF Research Database (Denmark)

    Abbasinia, M; Irajpour, A; Babaii, A

    2014-01-01

    INTRODUCTION: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate...... (RR), arterial blood oxygen saturation (SpO2) and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. METHODS: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were...... randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA), chi...

  5. Saturation and geometrical scaling

    CERN Document Server

    Praszalowicz, Michal

    2016-01-01

    We discuss emergence of geometrical scaling as a consequence of the nonlinear evolution equations of QCD, which generate a new dynamical scale, known as the saturation momentum: Qs. In the kinematical region where no other energy scales exist, particle spectra exhibit geometrical scaling (GS), i.e. they depend on the ratio pT=Qs, and the energy dependence enters solely through the energy dependence of the saturation momentum. We confront the hypothesis of GS in different systems with experimental data.

  6. Calibration of a neutron log in partially saturated media. Part II. Error analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hearst, J.R.; Kasameyer, P.W.; Dreiling, L.A.

    1981-03-20

    Four sources or error (uncertainty) are studied in water content obtained from neutron logs calibrated in partially saturated media for holes up to 3 m. For this calibration a special facility was built and an algorithm for a commercial epithermal neutron log was developed that obtains water content from count rate, bulk density, and gap between the neutron sonde and the borehole wall. The algorithm contained errors due to the calibration and lack of fit, while the field measurements included uncertainties in the count rate (caused by statistics and a short time constant), gap, and density. There can be inhomogeneity in the material surrounding the borehole. Under normal field conditions the hole-size-corrected water content obtained from such neutron logs can have an uncertainty as large as 15% of its value.

  7. Saturation of Zonal Flows

    Science.gov (United States)

    Kim, Eun-Jin

    2002-11-01

    Zonal flows (ZF) are generated by drift wave (DW) turbulence and then regulate it near marginality by shear suppression. Since collisions damp ZF while ZF suppress DW, the amplitude of DW turbulence (i.e. turbulent transport) is, in turn, proportional to collisionality. A key question is then what happens away from marginality, namely what is the saturation mechanism of ZF in that regime? This raises the interesting physical question of how ZF interact with mne 0, poloidally non-axisymmetric modes [1], both linearly and non linearly. We investigate this issue by exploring the nonlinear excitation of GKH modes by modulational instability in the background of finite amplitude of DW turbulence, as well as the linear inflection-type instability of ZF. In a simple model with cold ions, we show that ZF can grow faster than the linear GKH for γ/ωGKH modes can be comparable to their linear generation. Here, γ and ω are the growth rate and frequency of DW, and p and k are the characteristic wavenumbers of ZF and DW. These findings imply that the linear analysis of GKH may not always be valid and also that there may be no clear distinction between secondary (ZF) and tertiary mode (GKH). The effect of finite ion temperature fluctuations is incorporated in a simple toroidal ion temperature gradient model, within which both zonal flow and temperature are generated by modulational instability. The phase between the two is calculated self-consistently and shown to be positive. Furthermore, the correction to nonlinear generation of GKH modes appears to be small. [1] We refer to these low mne 0 modes as Generalized Kelvin-Helmholtz (GKH) modes, since they will appear as mne 0 distortions of a shear layer.

  8. Stable mode-locked operation of a low repetition rate diode-pumped Nd:GdVO4 laser by combining quadratic polarisation switching and a semiconductor saturable absorber mirror.

    Science.gov (United States)

    Gerhard, Christoph; Druon, Frédéric; Georges, Patrick; Couderc, Vincent; Leproux, Philippe

    2006-08-07

    In this paper, we present the mode-locked operation of an ultra-robustly stabilised Nd:GdVO(4) laser with low repetition rate by combining quadratic polarisation switching and a semiconductor saturable absorber mirror (SESAM). In addition, similar experiment was also done with Nd:YVO(4). For Nd:GdVO(4), 16-ps pulses at 1063 nm with a repetition rate of 3.95 MHz have been obtained for a laser average output power of 1.4 W. For Nd:YVO(4), the performance was 2.5 W of average power for 15-ps pulses at 1064 nm. Moreover, we demonstrate experimentally the advantage of combining these two passive mode locking techniques in terms of stability ranges. We show how the dual mode-locking technique is crucial to obtain a stable and long-term mode-locked regime in our case of a diode-pumped Nd:GdVO(4) laser operating at low repetition rate and more generally how this dual mode-locking technique improves the stability range of the mode-locked operation giving more flexibility on different parameters.

  9. Improved measurement of labile proton concentration-weighted chemical exchange rate (k(ws)) with experimental factor-compensated and T(1) -normalized quantitative chemical exchange saturation transfer (CEST) MRI.

    Science.gov (United States)

    Wu, Renhua; Liu, Charng-Ming; Liu, Philip K; Sun, Phillip Zhe

    2012-01-01

    Chemical exchange saturation transfer (CEST) MRI enables measurement of dilute CEST agents and microenvironment properties such as pH and temperature, holding great promise for in vivo applications. However, because of confounding concomitant radio frequency (RF) irradiation and relaxation effects, the CEST-weighted MRI contrast may not fully characterize the underlying CEST phenomenon. We postulated that the accuracy of quantitative CEST MRI could be improved if the experimental factors (labeling efficiency and RF spillover effect) were estimated and taken into account. Specifically, the experimental factor was evaluated as a function of exchange rate and CEST agent concentration ratio, which remained relatively constant for intermediate RF irradiation power levels. Hence, the experimental factors can be calculated based on the reasonably estimated exchange rate and labile proton concentration ratio, which significantly improved quantification. The simulation was confirmed with creatine phantoms of serially varied concentration titrated to the same pH, whose reverse exchange rate (k(ws)) was found to be linearly correlated with the concentration. In summary, the proposed solution provides simplified yet reasonably accurate quantification of the underlying CEST system, which may help guide the ongoing development of quantitative CEST MRI.

  10. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  11. Stability of an HIV Pathogenesis Model with Delay and Saturated Infection Rate%一类具有时滞和饱和传染率的HIV病理模型的稳定性分析

    Institute of Scientific and Technical Information of China (English)

    江志超; 霍东升; 郭照庄; 孙月芳

    2011-01-01

    本文研究了一类具有饱和传染率、治愈率和细胞内时滞的HIV病理模型。通过分析特征方程的特征根的分布情况,给出了正平衡点的存在性、绝对稳定和条件稳定的条件。在正平衡点条件稳定时,给出了正平衡点保持稳定的时滞长度。%An HIV Pathogenesis Model with saturated infection rate,cure rate and intracellular delay is analyzed.By analyzing the distribution of the roots of the characteristic equation,we give the existence and the conditions of absolute stability and conditional stability of the positive equilibrium.When the positive equilibrium is conditional stable,we give the delay longth for keeping the stability.

  12. Saturation of the turbulent dynamo.

    Science.gov (United States)

    Schober, J; Schleicher, D R G; Federrath, C; Bovino, S; Klessen, R S

    2015-08-01

    The origin of strong magnetic fields in the Universe can be explained by amplifying weak seed fields via turbulent motions on small spatial scales and subsequently transporting the magnetic energy to larger scales. This process is known as the turbulent dynamo and depends on the properties of turbulence, i.e., on the hydrodynamical Reynolds number and the compressibility of the gas, and on the magnetic diffusivity. While we know the growth rate of the magnetic energy in the linear regime, the saturation level, i.e., the ratio of magnetic energy to turbulent kinetic energy that can be reached, is not known from analytical calculations. In this paper we present a scale-dependent saturation model based on an effective turbulent resistivity which is determined by the turnover time scale of turbulent eddies and the magnetic energy density. The magnetic resistivity increases compared to the Spitzer value and the effective scale on which the magnetic energy spectrum is at its maximum moves to larger spatial scales. This process ends when the peak reaches a characteristic wave number k☆ which is determined by the critical magnetic Reynolds number. The saturation level of the dynamo also depends on the type of turbulence and differs for the limits of large and small magnetic Prandtl numbers Pm. With our model we find saturation levels between 43.8% and 1.3% for Pm≫1 and between 2.43% and 0.135% for Pm≪1, where the higher values refer to incompressible turbulence and the lower ones to highly compressible turbulence.

  13. Pump for Saturated Liquids

    Science.gov (United States)

    Elliott, D. G.

    1986-01-01

    Boiling liquids pumped by device based on proven components. Expanding saturated liquid in nozzle and diverting its phases along separate paths in liquid/vapor separator raises pressure of liquid. Liquid cooled in process. Pump makes it unnecessary to pressurize cryogenic liquids in order to pump them. Problems of introducing noncondensable pressurizing gas avoided.

  14. 基于 Android 的血氧饱和度和脉率检测系统设计%DESIGNING BLOOD OXYGEN SATURATION AND PULSE RATE MEASURING SYSTEM BASED ON ANDROID

    Institute of Scientific and Technical Information of China (English)

    田浩雨; 朱健铭; 梁永波; 殷世民; 陈真诚

    2016-01-01

    The measurement of blood oxygen saturation and pulse rate has great significance in people’s routine inspections,but the hospital physicals cost a lot of manpower and material resources.In view of this,the paper proposes an Android platform-based blood oxygen saturation and pulse rate parameters detection system.By analysing the pulse wave data of fingertip it is able to obtain multiple physiological parameters,the control of Bluetooth module by microcontroller is employed to achieve the communication with Android mobile devices and to implement the reception and display of physiological parameters,and in further the data exchange with Baidu cloud database is completed through 3G/4G network.This design overcomes the drawbacks of traditional wired devices in inconvenient moving,brings convenience to patients for their inspection.Experimental results show that to use this method can effectively improve the efficiency,realises remote inspection,and creates conditions for home monitoring and remote medical treatment.%血氧饱和度和脉率的检测在人们常规检查中有着重要意义,医院体检耗费大量人力物力。针对这种情况,提出一种基于Android 平台的血氧饱和度、脉率参数检测系统。通过分析指端脉搏波数据得出多项生理参数,利用单片机对蓝牙模块的控制,实现与 Android 移动设备通信,完成生理参数的接收、显示,并进一步通过3G/4G 网络,完成与百度云端数据库的数据交换。克服了传统有线设备移动不便的缺点,给病人检测带来便利。实验结果表明,采用该方法可以有效提高效率,实现远程监测,为家庭监护、远程医疗创造了条件。

  15. Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

    Energy Technology Data Exchange (ETDEWEB)

    Croft, Stephen [Oak Ridge National Laboratory (ORNL), One Bethel Valley Road, Oak Ridge, TN (United States); Burr, Tom [International Atomic Energy Agency (IAEA), Vienna (Austria); Favalli, Andrea [Los Alamos National Laboratory (LANL), MS E540, Los Alamos, NM 87545 (United States); Nicholson, Andrew [Oak Ridge National Laboratory (ORNL), One Bethel Valley Road, Oak Ridge, TN (United States)

    2016-03-01

    The declared linear density of {sup 238}U and {sup 235}U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar – Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of {sup 235}U (the response) in order to estimate model parameters of the nonlinear Padé equation, which traditionally is used to model the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This paper compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. We find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters.

  16. Count rate balance method of measuring sediment transport of sand beds by radioactive tracers; Methode du bilan des taux de comptage d'indicateurs radioactifs pour la determination du debit de charriage des lits sableux

    Energy Technology Data Exchange (ETDEWEB)

    Sauzay, G. [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1967-11-01

    Radioactive tracers are applied to the direct measurement of the sediment transport rate of sand beds. The theoretical measurement formula is derived: the variation of the count rate balance is inverse of that of the transport thickness. Simultaneously the representativeness of the tracer is critically studied. The minimum quantity of tracer which has to be injected in order to obtain a correct statistical definition of count rate given by a low number of grains 'seen' by the detector is then studied. A field experiment was made and has let to study the technological conditions for applying this method: only the treatment of results is new, the experiment itself is carried out with conventional techniques applied with great care. (author) [French] Les indicateurs radioactifs sont appliques a la mesure directe du debit de charriage des lits sableux. On etablit la formule theorique de mesure: le bilan des taux de comptage varie en sens inverse de l'epaisseur de charriage. Parallelement on fait une etude critique de la representativite de l'indicateur, puis on determine la quantite minimale de traceur qu'il faut immerger pour que les taux de comptage fournis pour un faible nombre de grains 'vus' par le detecteur aient une definition statistique correcte. Une experience de terrain a permis d'etudier les conditions technologiques de cette methode: seul le depouillement des resultats est nouveau. L'experimentation in-situ se fait suivant les procedes classiques avec un tres grand soin. (auteur)

  17. Comparison the Effects of Shallow and Deep Endotracheal Tube Suctioning on Respiratory Rate, Arterial Blood Oxygen Saturation and Number of Suctioning in Patients Hospitalized in the Intensive Care Unit: A Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasinia

    2014-09-01

    Full Text Available Introduction: Endotracheal tube suctioning is essential for improve oxygenation in the patients undergoing mechanical ventilation. There are two types of shallow and deep endotracheal tube suctioning. This study aimed to evaluate the effect of shallow and deep suctioning methods on respiratory rate (RR, arterial blood oxygen saturation (SpO2 and number of suctioning in patients hospitalized in the intensive care units of Al-Zahra Hospital, Isfahan, Iran. Methods: In this randomized controlled trial, 74 patients who hospitalized in the intensive care units of Isfahan Al-Zahra Hospital were randomly allocated to the shallow and deep suctioning groups. RR and SpO2 were measured immediately before, immediately after, 1 and 3 minute after each suctioning. Number of suctioning was also noted in each groups. Data were analyzed using repeated measures analysis of variance (RMANOVA, chi-square and independent t-tests. Results: RR was significantly increased and SpO2 was significantly decreased after each suctioning in the both groups. However, these changes were not significant between the two groups. The numbers of suctioning was significantly higher in the shallow suctioning group than in the deep suctioning group. Conclusion: Shallow and deep suctioning had a similar effect on RR and SpO2. However, shallow suctioning caused further manipulation of patient’s trachea than deep suctioning method. Therefore, it seems that deep endotracheal tube suctioning method can be used to clean the airway with lesser manipulation of the trachea.

  18. Nuclear Magnetic Resonance Measurements of Original Water Saturation and Mobile Water Saturation in Low Permeability Sandstone Gas

    Institute of Scientific and Technical Information of China (English)

    GAO Shu-Sheng; YE Li-You; XIONG Wei; GUO He-Kun; HU Zhi-Ming

    2010-01-01

    @@ We use nuclear magnetic resonance(NMR)and centrifugation to measure the original water saturation and mobile water saturation of cores from the Xujiahe low permeability sandstone gas reservoir,and compare the NMR results with the corresponding field data.It is shown that the NMR water saturation after 300 psi centrifugation effectively represents the original water saturation measured by weighing fresh cores.There is a good correlation between mobile water saturation and the water production performance of the corresponding gas wells.The critical mobile water saturation whether reservoir produces water of the Xujiahe low permeability sandstone gas is 6%.The higher the mobile water saturation,the greater the water production rate of gas well.This indicates that well's water production performance can be forecasted by mobile water saturation of cores.

  19. Health Physics counting room

    CERN Multimedia

    1970-01-01

    The Health Physics counting room, where the quantity of induced radioactivity in materials is determined. This information is used to evaluate possible radiation hazards from the material investigated.

  20. Conformal invariant saturation

    CERN Document Server

    Navelet, H

    2002-01-01

    We show that, in onium-onium scattering at (very) high energy, a transition to saturation happens due to quantum fluctuations of QCD dipoles. This transition starts when the order alpha^2 correction of the dipole loop is compensated by its faster energy evolution, leading to a negative interference with the tree level amplitude. After a derivation of the the one-loop dipole contribution using conformal invariance of the elastic 4-gluon amplitude in high energy QCD, we obtain an exact expression of the saturation line in the plane (Y,L) where Y is the total rapidity and L, the logarithm of the onium scale ratio. It shows universal features implying the Balitskyi - Fadin - Kuraev - Lipatov (BFKL) evolution kernel and the square of the QCD triple Pomeron vertex. For large L, only the higher BFKL Eigenvalue contributes, leading to a saturation depending on leading log perturbative QCD characteristics. For initial onium scales of same order, however, it involves an unlimited summation over all conformal BFKL Eigen...

  1. Ovarian response and cumulative live birth rate of women undergoing in-vitro fertilisation who had discordant anti-Mullerian hormone and antral follicle count measurements: a retrospective study.

    Science.gov (United States)

    Li, Hang Wun Raymond; Lee, Vivian Chi Yan; Lau, Estella Yee Lan; Yeung, William Shu Biu; Ho, Pak Chung; Ng, Ernest Hung Yu

    2014-01-01

    To evaluate ovarian response and cumulative live birth rate of women undergoing in-vitro fertilization (IVF) treatment who had discordant baseline serum anti-Mullerian hormone (AMH) level and antral follicle count (AFC). This is a retrospective cohort study on 1,046 women undergoing the first IVF cycle in Queen Mary Hospital, Hong Kong. Subjects receiving standard IVF treatment with the GnRH agonist long protocol were classified according to their quartiles of baseline AMH and AFC measurements after GnRH agonist down-regulation and before commencing ovarian stimulation. The number of retrieved oocytes, ovarian sensitivity index (OSI) and cumulative live-birth rate for each classification category were compared. Among our studied subjects, 32.2% were discordant in their AMH and AFC quartiles. Among them, those having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate. Subjects discordant in AMH and AFC had intermediate OSI which differed significantly compared to those concordant in AMH and AFC on either end. OSI of those discordant in AMH and AFC did not differ significantly whether either AMH or AFC quartile was higher than the other. When AMH and AFC are discordant, the ovarian responsiveness is intermediate between that when both are concordant on either end. Women having higher AMH within the same AFC quartile had higher number of retrieved oocytes and cumulative live-birth rate.

  2. 32-channel single photon counting module for ultrasensitive detection of DNA sequences

    Science.gov (United States)

    Gudkov, Georgiy; Dhulla, Vinit; Borodin, Anatoly; Gavrilov, Dmitri; Stepukhovich, Andrey; Tsupryk, Andrey; Gorbovitski, Boris; Gorfinkel, Vera

    2006-10-01

    We continue our work on the design and implementation of multi-channel single photon detection systems for highly sensitive detection of ultra-weak fluorescence signals, for high-performance, multi-lane DNA sequencing instruments. A fiberized, 32-channel single photon detection (SPD) module based on single photon avalanche diode (SPAD), model C30902S-DTC, from Perkin Elmer Optoelectronics (PKI) has been designed and implemented. Unavailability of high performance, large area SPAD arrays and our desire to design high performance photon counting systems drives us to use individual diodes. Slight modifications in our quenching circuit has doubled the linear range of our system from 1MHz to 2MHz, which is the upper limit for these devices and the maximum saturation count rate has increased to 14 MHz. The detector module comprises of a single board computer PC-104 that enables data visualization, recording, processing, and transfer. Very low dark count (300-1000 counts/s), robust, efficient, simple data collection and processing, ease of connectivity to any other application demanding similar requirements and similar performance results to the best commercially available single photon counting module (SPCM from PKI) are some of the features of this system.

  3. On the saturation of astrophysical dynamos

    DEFF Research Database (Denmark)

    Dorch, Bertil; Archontis, Vasilis

    2004-01-01

    In the context of astrophysical dynamos we illustrate that the no-cosines flow, with zero mean helicity, can drive fast dynamo action and we study the dynamo's mode of operation during both the linear and non-linear saturation regimes. It turns out that in addition to a high growth rate in the li......In the context of astrophysical dynamos we illustrate that the no-cosines flow, with zero mean helicity, can drive fast dynamo action and we study the dynamo's mode of operation during both the linear and non-linear saturation regimes. It turns out that in addition to a high growth rate...

  4. Anarthria impairs subvocal counting.

    Science.gov (United States)

    Cubelli, R; Nichelli, P; Pentore, R

    1993-12-01

    We studied subvocal counting in two pure anarthric patients. Analysis showed that they performed definitively worse than normal subjects free to articulate subvocally and their scores were in the lower bounds of the performances of subjects suppressing articulation. These results suggest that subvocal counting is impaired after anarthria.

  5. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  6. Correction of SOHO CELIAS/SEM EUV Measurements saturated by extreme solar flare events

    CERN Document Server

    Didkovsky, L V; Jones, A R; Wieman, S; Tsurutani, B T; McMullin, D

    2006-01-01

    The solar irradiance in the Extreme Ultraviolet (EUV) spectral bands has been observed with a 15 sec cadence by the SOHO Solar EUV Monitor (SEM) since 1995. During remarkably intense solar flares the SEM EUV measurements are saturated in the central (zero) order channel (0.1 -- 50.0 nm) by the flare soft X-ray and EUV flux. The first order EUV channel (26 -- 34 nm) is not saturated by the flare flux because of its limited bandwidth, but it is sensitive to the arrival of Solar Energetic Particles (SEP). While both channels detect nearly equal SEP fluxes, their contributions to the count rate is sensibly negligible in the zero order channel but must be accounted for and removed from the first channel count rate. SEP contribution to the measured SEM signals usually follows the EUV peak for the gradual solar flare events. Correcting the extreme solar flare SEM EUV measurements may reveal currently unclear relations between the flare magnitude, dynamics observed in different EUV spectral bands, and the measured Ea...

  7. Polar spots and stellar spindown: Is dynamo saturation needed?

    NARCIS (Netherlands)

    Solanki, S. K.; Motamen, S.; Keppens, R.

    1997-01-01

    Dynamo saturation is often invoked when calculating the rotational evolution of cool stars. At rapid rotation rates a saturated dynamo reduces the angular momentum carried away by the stellar wind. This, in turn, may explain the high rotation rates present in the distribution of rotation periods in

  8. Polar spots and stellar spindown: is dynamo saturation needed?

    NARCIS (Netherlands)

    Solanki, S. K.; Motamen, S.; Keppens, R.

    1997-01-01

    Dynamo saturation is often invoked when calculating the rotational evolution of cool stars. At rapid rotation rates a saturated dynamo reduces the angular momentum carried away by the stellar wind. This, in turn, may explain the high rotation rates present in the distribution of rotation periods in

  9. Polar spots and stellar spindown: Is dynamo saturation needed?

    NARCIS (Netherlands)

    Solanki, S. K.; Motamen, S.; Keppens, R.

    1997-01-01

    Dynamo saturation is often invoked when calculating the rotational evolution of cool stars. At rapid rotation rates a saturated dynamo reduces the angular momentum carried away by the stellar wind. This, in turn, may explain the high rotation rates present in the distribution of rotation periods in

  10. Polar spots and stellar spindown: is dynamo saturation needed?

    NARCIS (Netherlands)

    Solanki, S. K.; Motamen, S.; Keppens, R.

    1997-01-01

    Dynamo saturation is often invoked when calculating the rotational evolution of cool stars. At rapid rotation rates a saturated dynamo reduces the angular momentum carried away by the stellar wind. This, in turn, may explain the high rotation rates present in the distribution of rotation periods in

  11. Saturated logistic avalanche model

    Science.gov (United States)

    Aielli, G.; Camarri, P.; Cardarelli, R.; Di Ciaccio, A.; Liberti, B.; Paoloni, A.; Santonico, R.

    2003-08-01

    The search for an adequate avalanche RPC working model evidenced that the simple exponential growth can describe the electron multiplication phenomena in the gas with acceptable accuracy until the external electric field is not perturbed by the growing avalanche. We present here a model in which the saturated growth induced by the space charge effects is explained in a natural way by a constant coefficient non-linear differential equation, the Logistic equation, which was originally introduced to describe the evolution of a biological population in a limited resources environment. The RPCs, due to the uniform and intense field, proved to be an ideal device to test experimentally the presented model.

  12. Seven-day mortality can be predicted in medical patients by blood pressure, age, respiratory rate, loss of independence, and peripheral oxygen saturation (the PARIS score: a prospective cohort study with external validation.

    Directory of Open Access Journals (Sweden)

    Mikkel Brabrand

    Full Text Available Most existing risk stratification systems predicting mortality in emergency departments or admission units are complex in clinical use or have not been validated to a level where use is considered appropriate. We aimed to develop and validate a simple system that predicts seven-day mortality of acutely admitted medical patients using routinely collected variables obtained within the first minutes after arrival.This observational prospective cohort study used three independent cohorts at the medical admission units at a regional teaching hospital and a tertiary university hospital and included all adult (≥ 15 years patients. Multivariable logistic regression analysis was used to identify the clinical variables that best predicted the endpoint. From this, we developed a simplified model that can be calculated without specialized tools or loss of predictive ability. The outcome was defined as seven-day all-cause mortality. 76 patients (2.5% met the endpoint in the development cohort, 57 (2.0% in the first validation cohort, and 111 (4.3% in the second. Systolic blood Pressure, Age, Respiratory rate, loss of Independence, and peripheral oxygen Saturation were associated with the endpoint (full model. Based on this, we developed a simple score (range 0-5, ie, the PARIS score, by dichotomizing the variables. The ability to identify patients at increased risk (discriminatory power and calibration was excellent for all three cohorts using both models. For patients with a PARIS score ≥ 3, sensitivity was 62.5-74.0%, specificity 85.9-91.1%, positive predictive value 11.2-17.5%, and negative predictive value 98.3-99.3%. Patients with a score ≤ 1 had a low mortality (≤ 1%; with 2, intermediate mortality (2-5%; and ≥ 3, high mortality (≥ 10%.Seven-day mortality can be predicted upon admission with high sensitivity and specificity and excellent negative predictive values.

  13. CIX - A Detector for Spectral Enhanced X-ray Imaging by Simultaneous Counting and Integrating

    CERN Document Server

    Krüger, H; Kraft, E; Wermes, N; Fischer, P; Peric, I; Herrmann, C; Overdick, M; Rütten, W

    2008-01-01

    A hybrid pixel detector based on the concept of simultaneous charge integration and photon counting will be presented. The second generation of a counting and integrating X-ray prototype CMOS chip (CIX) has been operated with different direct converting sensor materials (CdZnTe and CdTe) bump bonded to its 8x8 pixel matrix. Photon counting devices give excellent results for low to medium X-ray fluxes but saturate at high rates while charge integration allows the detection of very high fluxes but is limited at low rates by the finite signal to noise ratio. The combination of both signal processing concepts therefore extends the resolvable dynamic range of the X-ray detector. In addition, for a large region of the dynamic range, where counter and integrator operate simultaneously, the mean energy of the detected X-ray spectrum can be calculated. This spectral information can be used to enhance the contrast of the X-ray image. The advantages of the counting and integrating signal processing concept and the perfo...

  14. Sublattice Counting and Orbifolds

    CERN Document Server

    Hanany, Amihay; Reffert, Susanne

    2010-01-01

    Abelian orbifolds of C^3 are known to be encoded by hexagonal brane tilings. To date it is not known how to count all such orbifolds. We fill this gap by employing number theoretic techniques from crystallography, and by making use of Polya's Enumeration Theorem. The results turn out to be beautifully encoded in terms of partition functions and Dirichlet Series. The same methods apply to counting orbifolds of any toric non-compact Calabi-Yau singularity. As additional examples, we count the orbifolds of the conifold, of the L^{aba} theories, and of C^4.

  15. Sample to answer visualization pipeline for low-cost point-of-care blood cell counting

    Science.gov (United States)

    Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter

    2015-03-01

    We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.

  16. Influences of temperature and saturation states on the precipitation rate of calcium carbonates%温度和过饱和度对海水中碳酸钙沉淀速率的影响Ⅰ.镁方解石

    Institute of Scientific and Technical Information of China (English)

    瞿成利; 刘刚; 路波

    2009-01-01

    Using the constant addition system, the precipitation of Mg-calcite in seawater was experimentally investigated at 5, 15, and 25 ℃. It was observed that, at each temperature, the relation between Mg-calcite precipitation rates and saturation states can be well expressed in the kinetic form of R=k(Ω-1) or Log(R)=nLog(Ω-1)+Log(k). The change of pCO2 would result in the remarkable variation of Mg-calcite precipitation rates, while it would not affect the kinetic expression of Mg-calcite precipitation. On the other hand, there are remarkable discrepancies among the kinetic expressions obtained at different temperatures, which indicate the thermodynamic relevance of the kinetic process of Mg-calcite precipitation.%采用稳定加液一反应系统对5、15和25 ° C下镁方解石沉淀在海水中的形成过程进行了研究.结果表明镁方解石的沉淀速率(R)对过饱和度(Ω)的响应均可通过R=k(Ω-1)°或Log(R)=nLog(Ω-1)+Log(k)形式的动力学方程加以表达.pCO2的变化会显著改变过饱和度进而影响到镁方解石沉淀速率,但这一变化并不会对镁方解石沉淀形成过程的动力学表达产生影响.相比之下,不同温度下镁方解石沉淀形成的动力学方程存在明显差异,表明这一动力学过程同时还具有强烈的热力学相关性.

  17. 1996 : Track Count Protocol

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The goal of St. Vincent National Wildlife Refuge's Track Count Protocol is to provide an index to the population size of game animals inhabiting St. Vincent Island.

  18. Blood Count Tests

    Science.gov (United States)

    Your blood contains red blood cells (RBC), white blood cells (WBC), and platelets. Blood count tests measure the number and types of cells in your blood. This helps doctors check on your overall health. ...

  19. Counting Belief Propagation

    CERN Document Server

    Kersting, Kristian; Natarajan, Sriraam

    2012-01-01

    A major benefit of graphical models is that most knowledge is captured in the model structure. Many models, however, produce inference problems with a lot of symmetries not reflected in the graphical structure and hence not exploitable by efficient inference techniques such as belief propagation (BP). In this paper, we present a new and simple BP algorithm, called counting BP, that exploits such additional symmetries. Starting from a given factor graph, counting BP first constructs a compressed factor graph of clusternodes and clusterfactors, corresponding to sets of nodes and factors that are indistinguishable given the evidence. Then it runs a modified BP algorithm on the compressed graph that is equivalent to running BP on the original factor graph. Our experiments show that counting BP is applicable to a variety of important AI tasks such as (dynamic) relational models and boolean model counting, and that significant efficiency gains are obtainable, often by orders of magnitude.

  20. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  1. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  2. Liquid Scintillation Counting

    OpenAIRE

    Carlsson, Sten

    1993-01-01

    In liquid scintillation counting (LSC) we use the process of luminescense to detect ionising radiation emit$ed from a radionuclide. Luminescense is emission of visible light of nonthermal origin. 1t was early found that certain organic molecules have luminescent properties and such molecules are used in LSC. Today LSC is the mostwidespread method to detect pure beta-ernitters like tritium and carbon-14. 1t has unique properties in its efficient counting geometry, deteetability and the lack of...

  3. Counting curves on surfaces

    OpenAIRE

    2015-01-01

    In this paper we consider an elementary, and largely unexplored, combinatorial problem in low-dimensional topology. Consider a real 2-dimensional compact surface $S$, and fix a number of points $F$ on its boundary. We ask: how many configurations of disjoint arcs are there on $S$ whose boundary is $F$? We find that this enumerative problem, counting curves on surfaces, has a rich structure. For instance, we show that the curve counts obey an effective recursion, in the general framework of to...

  4. Counting RG flows

    OpenAIRE

    Gukov, Sergei

    2016-01-01

    Interpreting renormalization group flows as solitons interpolating between different fixed points, we ask various questions that are normally asked in soliton physics but not in renormalization theory. Can one count RG flows? Are there different "topological sectors" for RG flows? What is the moduli space of an RG flow, and how does it compare to familiar moduli spaces of (supersymmetric) dowain walls? Analyzing these questions in a wide variety of contexts --- from counting RG walls to AdS/C...

  5. Magnetic Field Saturation in the Riga Dynamo Experiment

    CERN Document Server

    Gailitis, A; Platacis, E; Dementev, S; Cifersons, A; Gerbeth, G; Gundrum, T; Stefani, F; Christen, M; Will, G; Gailitis, Agris; Lielausis, Olgerts; Platacis, Ernests; Dement'ev, Sergej; Cifersons, Arnis; Gerbeth, Gunter; Gundrum, Thomas; Stefani, Frank; Christen, Michael; Will, Gotthard

    2001-01-01

    After the dynamo experiment in November 1999 had shown magnetic field self-excitation in a spiraling liquid metal flow, in a second series of experiments emphasis was placed on the magnetic field saturation regime as the next principal step in the dynamo process. The dependence of the strength of the magnetic field on the rotation rate is studied. Various features of the saturated magnetic field are outlined and possible saturation mechanisms are discussed.

  6. 基于聚类NASVD的CE2-GRS月表放射性元素Th计数率分布%Distribution of the Thorium Counting Rate on the Lunar Surface from CE2-GRS Based on Cluster NASVD

    Institute of Scientific and Technical Information of China (English)

    李晓丽; 葛良全; 杨佳; 熊盛青

    2015-01-01

    月表Th元素分布特征对于分析月表岩石成因及化学特征等提供了重要依据。为了减小嫦娥二号伽玛谱(CE2-GRS)噪声对获取Th元素分布特征的影响,提出了一种基于噪声调整的奇异值分解(NASVD)去噪算法。通过伽玛谱预处理、去噪、本底扣除及净峰面积求解等步骤,获得月表放射性元素Th计数率全月分布图。通过与国内外其他方法所获得的Th元素计数率分布图对比有较高的一致性。与传统伽玛谱去噪算法比较,聚类NASVD算法能有效地去除统计涨落噪声影响,提取出嫦娥二号伽玛谱中的特征峰信息。%The distribution of thorium on the lunar surface provides the important evidence for lunar evolution history. It is difficult to obtain the distribution of thorium on the lunar surface from CE2-GRS because of noise in the spectrum. The method for smoothing the spectrum is proposed which is based on cluster NASVD. The counting rate map of thorium on the lunar surface is achieved from CE2-GRS. Counting rate map of thorium gamma-rays shows a surface thorium distribution that is in general agreement with other measurement from LP-GRS and SLENE GRS which have better accuracy. It is more effectively to reduce the noise and get the weak information of characteristic peak used the method of cluster NASVD than other traditional methods for smoothing gamma-ray spectrum.

  7. [Blood Count Specimen].

    Science.gov (United States)

    Tamura, Takako

    2015-12-01

    The circulating blood volume accounts for 8% of the body weight, of which 45% comprises cellular components (blood cells) and 55% liquid components. We can measure the number and morphological features of blood cells (leukocytes, red blood cells, platelets), or count the amount of hemoglobin in a complete blood count: (CBC). Blood counts are often used to detect inflammatory diseases such as infection, anemia, a bleeding tendency, and abnormal cell screening of blood disease. This count is widely used as a basic data item of health examination. In recent years, clinical tests before consultation have become common among outpatient clinics, and the influence of laboratory values on consultation has grown. CBC, which is intended to count the number of raw cells and to check morphological features, is easily influenced by the environment, techniques, etc., during specimen collection procedures and transportation. Therefore, special attention is necessary to read laboratory data. Providing correct test values that accurately reflect a patient's condition from the laboratory to clinical side is crucial. Inappropriate medical treatment caused by erroneous values resulting from altered specimens should be avoided. In order to provide correct test values, the daily management of devices is a matter of course, and comprehending data variables and positively providing information to the clinical side are important. In this chapter, concerning sampling collection, blood collection tubes, dealing with specimens, transportation, and storage, I will discuss their effects on CBC, along with management or handling methods.

  8. Testing Saturation at Hadron Colliders

    CERN Document Server

    Marquet, C

    2003-01-01

    We extend the saturation models a la Golec-Biernat and Wusthoff to cross-sections of hard processes initiated by virtual-gluon probes separated by large rapidity intervals at hadron colliders. We derive their analytic expressions and apply them to physical examples, such as saturation effects for Mueller-Navelet jets. By comparison to gamma*-gamma* cross-sections we find a more abrupt transition to saturation. We propose to study observables with a potentially clear saturation signal and to use heavy vector and flavored mesons as alternative virtual-gluon probes.

  9. Saturated fats: what dietary intake?

    Science.gov (United States)

    German, J Bruce; Dillard, Cora J

    2004-09-01

    Public health recommendations for the US population in 1977 were to reduce fat intake to as low as 30% of calories to lower the incidence of coronary artery disease. These recommendations resulted in a compositional shift in food materials throughout the agricultural industry, and the fractional content of fats was replaced principally with carbohydrates. Subsequently, high-carbohydrate diets were recognized as contributing to the lipoprotein pattern that characterizes atherogenic dyslipidemia and hypertriacylglycerolemia. The rising incidences of metabolic syndrome and obesity are becoming common themes in the literature. Current recommendations are to keep saturated fatty acid, trans fatty acid, and cholesterol intakes as low as possible while consuming a nutritionally adequate diet. In the face of such recommendations, the agricultural industry is shifting food composition toward lower proportions of all saturated fatty acids. To date, no lower safe limit of specific saturated fatty acid intakes has been identified. This review summarizes research findings and observations on the disparate functions of saturated fatty acids and seeks to bring a more quantitative balance to the debate on dietary saturated fat. Whether a finite quantity of specific dietary saturated fatty acids actually benefits health is not yet known. Because agricultural practices to reduce saturated fat will require a prolonged and concerted effort, and because the world is moving toward more individualized dietary recommendations, should the steps to decrease saturated fatty acids to as low as agriculturally possible not wait until evidence clearly indicates which amounts and types of saturated fatty acids are optimal?

  10. Static gain saturation in quantum dot semiconductor optical amplifiers.

    Science.gov (United States)

    Meuer, Christian; Kim, Jungho; Laemmlin, Matthias; Liebich, Sven; Capua, Amir; Eisenstein, Gadi; Kovsh, Alexey R; Mikhrin, Sergey S; Krestnikov, Igor L; Bimberg, Dieter

    2008-05-26

    Measurements of saturated amplified spontaneous emission-spectra of quantum dot semiconductor optical amplifiers demonstrate efficient replenishment of the quantum-dot ground state population from excited states. This saturation behavior is perfectly modeled by a rate equation model. We examined experimentally the dependence of saturation on the drive current and the saturating optical pump power as well as on the pump wavelength. A coherent noise spectral hole is observed with which we assess dynamical properties and propose optimization of the SOA operating parameters for high speed applications.

  11. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H. [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  12. 血小板数量对血浆比浊法测定血小板聚集率的影响%The Effect of Different Platelet Counts for Plasma Turbidimetry on Platelet Aggregation Rate

    Institute of Scientific and Technical Information of China (English)

    张庆

    2015-01-01

    Objective To investigate the effect of platelet counts on platelet aggregation test,to regulate platelet aggrega-tion rate detection to improve detection quality,in order to ensure the reliability of measurements of platelet aggregation. Meth-ods 211 cases of healthy people venous whole blood samples were included and centrifuged to obtain platelet-rich plasma ( plate-let-rich plasma,PRP) and platelet-poor plasma (platelet-poor plasma,PPP),the PRP with PPP got different dilutions of platelet concentration of PRP samples tested ,concentration of PRP platelet were confirmed in plasma;Platelet aggregation rate was detected by platelet aggregation nephelometry, and discuss the correlation with platelet. Results Adenosine diphosphate ( ADP ) and arachidonic acid( AA) induced platelet aggregation rate within a laboratory setting reference range. with decreasing concentration of platelet,the aggregation rate decreased significantly(P<0. 05);when the concentration was reduced to <95 ×109/L,the aggre-gate rate of the test resulted below the established reference range;platelet 90~350 × 10 9/L was significantly correlation with the accumulation(rAA =0. 67,rADP =0. 69),other concentrations and aggregation had no correlation. Conclusion Platelet concentra-tion can affect platelet aggregation rate,determination of aggregation rate should be limited at above of 95 × 10 9/L,which reflect the relation of concentration and aggregation rate,and accurately reflect the concentration of aggregation.%目的 探讨血小板数量对血小板聚集率检测的影响,提高检测质量,保证聚集率测定结果的可靠性. 方法 收集211例健康人静脉全血标本,离心获取富血小板血浆( platelet-rich plasma,PRP)和乏血小板血浆( platelet-poor plas-ma,PPP) ,将PRP用自身PPP梯度稀释后获取不同血小板浓度的PRP检测样本,并确认PRP血浆中血小板浓度;利用血浆比浊法测定血小板聚集率,讨论血小板数量与血小

  13. What Counts as Evidence?

    Science.gov (United States)

    Dougherty Stahl, Katherine A.

    2014-01-01

    Each disciplinary community has its own criteria for determining what counts as evidence of knowledge in their academic field. The criteria influence the ways that a community's knowledge is created, communicated, and evaluated. Situating reading, writing, and language instruction within the content areas enables teachers to explicitly…

  14. What Counts as Prostitution?

    Directory of Open Access Journals (Sweden)

    Stuart P. Green

    2016-08-01

    Full Text Available What counts, or should count, as prostitution? In the criminal law today, prostitution is understood to involve the provision of sexual services in exchange for money or other benefits. But what exactly is a ‘sexual service’? And what exactly is the nature of the required ‘exchange’? The key to answering these questions is to recognize that how we choose to define prostitution will inevitably depend on why we believe one or more aspects of prostitution are wrong or harmful, or should be criminalized or otherwise deterred, in the first place. These judgements, in turn, will often depend on an assessment of the contested empirical evidence on which they rest. This article describes a variety of real-world contexts in which the ‘what counts as prostitution’ question has arisen, surveys a range of leading rationales for deterring prostitution, and demonstrates how the answer to the definition question depends on the answer to the normative question. The article concludes with some preliminary thoughts on how analogous questions about what should count as sexual conduct arise in the context of consensual offences such as adultery and incest, as well as non-consensual offences such as sexual assault.

  15. Saturation dynamics and working limits of saturated absorption cavity ringdown spectroscopy.

    Science.gov (United States)

    Sadiek, Ibrahim; Friedrichs, Gernot

    2016-08-17

    Cavity ringdown spectroscopy (CRDS) in the linear absorption regime is a well-established method for sensitive trace gas detection, but only a few studies have addressed quantitative measurements in the presence of a saturated sample. In fact, saturation is usually avoided in order to escape from the required complex modeling of the saturation process that depends on the characteristics of the absorbing species, its interaction with the surrounding gas as well as on the temporal and spectral characteristics of the cavity excitation. Conversely, the novel saturated-absorption cavity ringdown spectroscopy approach (SCAR/Sat-CRDS) takes advantage of sample saturation in order to allow one to extract both the gas absorption and the empty cavity loss rates from a single ringdown event. Using a new continuous-wave infrared CRD spectrometer equipped with a tunable narrow-bandwidth high-power OPO laser system and a 18 bit digitizer, the transient dynamics of absorption saturation and the working limits of the Sat-CRDS approach in terms of its ability to extract reliable trace gas concentrations have been experimentally studied in this work. Using a strong methane transition as a test case, the excitation power P0 and saturation power PS have been systematically varied to explore a wide range of saturation regimes. At pressures 5 μbar γc, a pronounced coupling between the two parameters has been observed. Finally, a standard error analysis was performed revealing that the Sat-CRDS approach holds its advantages over conventional CRDS implementations in particular when the attainable ultimate detection sensitivity is limited by uncertainties in the empty cavity ringdown constant.

  16. Brief Review of Saturation Physics

    CERN Document Server

    Kovchegov, Yuri V

    2014-01-01

    We present a short overview of saturation physics followed by a summary of the recent progress in our understanding of nonlinear small-$x$ evolution. Topics include McLerran-Venugopalan model, Glauber-Mueller approximation, nonlinear BK/JIMWLK evolution equations, along with the running-coupling and NLO corrections to these equations. We conclude with selected topics in saturation phenomenology.

  17. Brine Distribution after Vacuum Saturation

    DEFF Research Database (Denmark)

    Hedegaard, Kathrine; Andersen, Bertel Lohmann

    1999-01-01

    Experiments with the vacuum saturation method for brine in plugs of chalk showed that a homogeneous distribution of brine cannot be ensured at saturations below 20% volume. Instead of a homogeneous volume distribution the brine becomes concentrated close to the surfaces of the plugs...

  18. VARUN: discovering extensible motifs under saturation constraints.

    Science.gov (United States)

    Apostolico, Alberto; Comin, Matteo; Parida, Laxmi

    2010-01-01

    The discovery of motifs in biosequences is frequently torn between the rigidity of the model on one hand and the abundance of candidates on the other hand. In particular, motifs that include wild cards or "don't cares" escalate exponentially with their number, and this gets only worse if a don't care is allowed to stretch up to some prescribed maximum length. In this paper, a notion of extensible motif in a sequence is introduced and studied, which tightly combines the structure of the motif pattern, as described by its syntactic specification, with the statistical measure of its occurrence count. It is shown that a combination of appropriate saturation conditions and the monotonicity of probabilistic scores over regions of constant frequency afford us significant parsimony in the generation and testing of candidate overrepresented motifs. A suite of software programs called Varun is described, implementing the discovery of extensible motifs of the type considered. The merits of the method are then documented by results obtained in a variety of experiments primarily targeting protein sequence families. Of equal importance seems the fact that the sets of all surprising motifs returned in each experiment are extracted faster and come in much more manageable sizes than would be obtained in the absence of saturation constraints.

  19. The distribution of saturated clusters in wetted granular materials

    Science.gov (United States)

    Li, Shuoqi; Hanaor, Dorian; Gan, Yixiang

    2017-06-01

    The hydro-mechanical behaviour of partially saturated granular materials is greatly influenced by the spatial and temporal distribution of liquid within the media. The aim of this paper is to characterise the distribution of saturated clusters in granular materials using an optical imaging method under different water drainage conditions. A saturated cluster is formed when a liquid phase fully occupies the pore space between solid grains in a localized region. The samples considered here were prepared by vibrating mono-sized glass beads to form closely packed assemblies in a rectangular container. A range of drainage conditions were applied to the specimen by tilting the container and employing different flow rates, and the liquid pressure was recorded at different positions in the experimental cell. The formation of saturated clusters during the liquid withdrawal processes is governed by three competing mechanisms arising from viscous, capillary, and gravitational forces. When the flow rate is sufficiently large and the gravity component is sufficiently small, the viscous force tends to destabilize the liquid front leading to the formation of narrow fingers of saturated material. As the water channels along these liquid fingers break, saturated clusters are formed inside the specimen. Subsequently, a spatial and temporal distribution of saturated clusters can be observed. We investigated the resulting saturated cluster distribution as a function of flow rate and gravity to achieve a fundamental understanding of the formation and evolution of such clusters in partially saturated granular materials. This study serves as a bridge between pore-scale behavior and the overall hydro-mechanical characteristics in partially saturated soils.

  20. Broadband fast semiconductor saturable absorber.

    Science.gov (United States)

    Jacobovitz-Veselka, G R; Kellerm, U; Asom, T

    1992-12-15

    Kerr lens mode-locked (KLM) solid-state lasers are typically not self-starting. We address this problem by introducing a broadband semiconductor saturable absorber that could be used as a tunable, all-solid-state, passive starting mechanism. We extend the wavelength tunability of a semiconductor saturable absorber to more than 100 nm using a band-gap-engineered low-temperature molecular-beam-epitaxy (MBE)-grown bulk AlGaAs semiconductor saturable absorber in which the absorption edge of the saturable absorber has been artificially broadened by continuously reducing the Al concentration during the MBE growth. We demonstrate its tunability and its feasibility as a starting mechanism for KLM with a picosecond resonant passive mode-locked Ti:sapphire laser. The extension to femtosecond KLM lasers has been discussed previously.

  1. The right to count does not always count

    DEFF Research Database (Denmark)

    Sodemann, Morten

    2013-01-01

    The best prescription against illness is learning to read and to count. People who are unable to count have a harder time learning to read. People who have difficulty counting make poorer decisions, are less able to combine information and are less likely to have a strategy for life...

  2. Nitrogen saturation in humid tropical forests after 6 years of nitrogen and phosphorus addition

    DEFF Research Database (Denmark)

    Chen, Hao; Gurmesa, Geshere A.; Zhang, Wei

    2016-01-01

    Nitrogen (N) saturation hypothesis suggests that when an ecosystem reaches N-saturation, continued N input will cause increased N leaching, nitrous oxide (N2O) emission, and N mineralization and nitrification rates. It also suggests that a different element will become the main limiting......O emission rate and nitrate (NO3-) leaching rate were measured in an N-saturated old-growth tropical forest in southern China, after 6 years of N and P addition. We hypothesized that N addition would stimulate further N saturation, but P addition might alleviate N saturation. As expected, our...

  3. Evolutions of Compaction Bands of Saturated Soils

    Institute of Scientific and Technical Information of China (English)

    鲁晓兵; 王义华; 崔鹏

    2004-01-01

    The development of compaction bands in saturated soils, which is coupling-rate, inertial and pore-pressure-dependent, under axisymmetric loading was discussed, using a simple model and a matching technique at the moving boundary of a band. It is shown that the development of compaction bands is dominated by the coupling-rate and pore-pressure effects of material. The soil strength makes the band shrinking, whilst pore pressure diffusion makes the band expand. Numerical simulations were carried out in this paper.

  4. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  5. High Red Blood Cell Count

    Science.gov (United States)

    Symptoms High red blood cell count By Mayo Clinic Staff A high red blood cell count is an increase in oxygen-carrying cells in your bloodstream. Red blood cells transport oxygen from your lungs to tissues throughout ...

  6. Counting and Topological Order

    Institute of Scientific and Technical Information of China (English)

    陈阳军

    1997-01-01

    The counting method is a simple and efficient method for processing linear recursive datalog queries.Its time complexity is bounded by O(n,e)where n and e denote the numbers the numbers of nodes and edges,respectively,in the graph representing the input.relations.In this paper,the concepts of heritage appearance function and heritage selection function are introduced,and an evaluation algorithm based on the computation of such functions in topological order is developed .This new algorithm requires only linear time in the case of non-cyclic data.

  7. Death rates in HIV-positive antiretroviral-naive patients with CD4 count greater than 350 cells per microL in Europe and North America: a pooled cohort observational study

    DEFF Research Database (Denmark)

    Lodwick, Rebecca K; Sabin, Caroline A; Porter, Kholoud;

    2010-01-01

    Whether people living with HIV who have not received antiretroviral therapy (ART) and have high CD4 cell counts have higher mortality than the general population is unknown. We aimed to examine this by analysis of pooled data from industrialised countries....

  8. Single electron counting using a dual MCP assembly

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yuzhen [School of Physics, Nanjing University, Nanjing 210093 (China); Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Liu, Shulin, E-mail: liusl@ihep.ac.cn [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Zhao, Tianchi, E-mail: tianchi@u.washington.edu [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Department of Physics, University of Washington, Seattle, WA 98195 (United States); Yan, Baojun; Wang, Peiliang [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Yu, Yang [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); School of Science, Xi’an University of Technology, Xi’an 710048 (China); Lei, Xiangcui [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Yang, Luping [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); School of Physics and Electronics, Henan University, Kaifeng 475004 (China); Wen, Kaile [Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); State Key Laboratory of Particle Detection and Electronics, Beijing 100049 (China); Qi, Ming [School of Physics, Nanjing University, Nanjing 210093 (China); and others

    2016-09-11

    The gain, pulse height resolution and peak-to-valley ratio of single electrons detected by using a Chevron configured Microchannel Plate (MCP) assembly are studied. The two MCPs are separated by a 280 µm gap and are biased by four electrodes. The purpose of the study is to determine the optimum bias voltage arrangements for single electron counting. By comparing the results of various bias voltage combinations, we conclude that good performance for the electron counting can be achieved by operating the MCP assembly in saturation mode. In addition, by applying a small reverse bias voltage across the gap while adjusting the bias voltages of the MCPs, optimum performance of electron counting can be obtained. - Highlights: • Dual MCPs assembly with four electrodes using different voltage combinations has been investigated for single electron counting. • Both the MCP voltages and the gap voltage can affect the gain, pulse height resolution and P/V ratio. • A high gain of the first stage MCP, a saturation mode of the second stage MCP and an appropriately reverse gap voltage can improve the resolution greatly. • The optimum voltage arrangements is significant for the design of MCP detectors in single electron counting applications.

  9. Theory of graphene saturable absorption

    CERN Document Server

    Marini, A; de Abajo, F J Garcia

    2016-01-01

    Saturable absorption is a non-perturbative nonlinear optical phenomenon that plays a pivotal role in the generation of ultrafast light pulses. Here we show that this effect emerges in graphene at unprecedentedly low light intensities, thus opening avenues to new nonlinear physics and applications in optical technology. Specifically, we theoretically investigate saturable absorption in extended graphene by developing a non-perturbative single-particle approach, describing conduction-electron dynamics in the atomically-thin material using the two-dimensional Dirac equation for massless Dirac fermions, which is recast in the form of generalized Bloch equations. By solving the electron dynamics non-perturbatively, we account for both interband and intraband contributions to the intensity-dependent saturated conductivity and conclude that the former dominates regardless of the intrinsic doping state of the material. The results are in excellent agreement with atomistic quantum-mechanical simulations including high...

  10. Information point and saturation flow at signalized intersections

    Directory of Open Access Journals (Sweden)

    Lijun Gao

    2016-08-01

    Full Text Available This paper introduces an information point factor and attempts to identify how it affects saturation flow and their relationship at signalized intersections. An information point is defined as any object, structure, or activity located outside of a traveling vehicle that can potentially attract the visual attention of the driver. Saturation flow rates are studied at three pairs of signalized intersections in Toledo, Ohio, USA. Each pair of intersections consists of one intersection with a high number of information points and one intersection with a low number of information points. Study results reveal that, for each pair of intersections, the one with high information points has a lower saturation flow rate than the one with low information points. A statistical analysis shows that the differences are significant. Based on the saturation flow data of the paired intersections, information point effect models are developed and presented in this paper.

  11. Counting coalescent histories.

    Science.gov (United States)

    Rosenberg, Noah A

    2007-04-01

    Given a species tree and a gene tree, a valid coalescent history is a list of the branches of the species tree on which coalescences in the gene tree take place. I develop a recursion for the number of valid coalescent histories that exist for an arbitrary gene tree/species tree pair, when one gene lineage is studied per species. The result is obtained by defining a concept of m-extended coalescent histories, enumerating and counting these histories, and taking the special case of m = 1. As a sum over valid coalescent histories appears in a formula for the probability that a random gene tree evolving along the branches of a fixed species tree has a specified labeled topology, the enumeration of valid coalescent histories can considerably reduce the effort required for evaluating this formula.

  12. Oscillations in counting statistics

    CERN Document Server

    Wilk, Grzegorz

    2016-01-01

    The very large transverse momenta and large multiplicities available in present LHC experiments on pp collisions allow a much closer look at the corresponding distributions. Some time ago we discussed a possible physical meaning of apparent log-periodic oscillations showing up in p_T distributions (suggesting that the exponent of the observed power-like behavior is complex). In this talk we concentrate on another example of oscillations, this time connected with multiplicity distributions P(N). We argue that some combinations of the experimentally measured values of P(N) (satisfying the recurrence relations used in the description of cascade-stochastic processes in quantum optics) exhibit distinct oscillatory behavior, not observed in the usual Negative Binomial Distributions used to fit data. These oscillations provide yet another example of oscillations seen in counting statistics in many different, apparently very disparate branches of physics further demonstrating the universality of this phenomenon.

  13. Counting Statistics and Ion Interval Density in AMS

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, J S; Ognibene, T; Palmblad, M; Reimer, P

    2004-08-03

    Confidence in the precisions of AMS and decay measurements must be comparable for the application of the {sup 14}C calibration to age determinations using both technologies. We confirmed the random nature of the temporal distribution of {sup 14}C ions in an AMS spectrometer for a number of sample counting rates and properties of the sputtering process. The temporal distribution of ion counts was also measured to confirm the applicability of traditional counting statistics.

  14. Resonance trapping and saturation of decay widths

    CERN Document Server

    Persson, E; Rotter, I

    1998-01-01

    Resonance trapping appears in open many-particle quantum systems at high level density when the coupling to the continuum of decay channels reaches a critical strength. Here a reorganization of the system takes place and a separation of different time scales appears. We investigate it under the influence of additional weakly coupled channels as well as by taking into account the real part of the coupling term between system and continuum. We observe a saturation of the mean width of the trapped states. Also the decay rates saturate as a function of the coupling strength. The mechanism of the saturation is studied in detail. In any case, the critical region of reorganization is enlarged. When the transmission coefficients for the different channels are different, the width distribution is broadened as compared to a chi_K^2 distribution where K is the number of channels. Resonance trapping takes place before the broad state overlaps regions beyond the extension of the spectrum of the closed system.

  15. Colony counting on hydrophobic grid-membrane filters.

    Science.gov (United States)

    Sharpe, A N; Diotte, M P; Dudas, I; Malcolm, S; Peterkin, P I

    1983-07-01

    A device to facilitate manual scoring of hydrophobic grid-membrane filters (HGMF) is described. Variations in scores were generally less than 2.5% between 41 analysts from six laboratories, who, using the apparatus, scored a set of five specimen HGMF in different ways, and there was good agreement between scores from positive and negative grid-cell counts by each analyst. A scoring procedure for use in routine microbiological analysis, suitable for HGMF at various degrees of saturation, is recommended.

  16. CERN_DxCTA counting mode chip

    CERN Document Server

    Moraes, D; Nygård, E

    2008-01-01

    This ASIC is a counting mode front-end electronic optimized for the readout of CdZnTe/CdTe and silicon sensors, for possible use in applications where the flux of ionizing radiation is high. The chip is implemented in 0.25 μm CMOS technology. The circuit comprises 128 channels equipped with a transimpedance amplifier followed by a gain shaper stage with 21 ns peaking time, two discriminators and two 18-bit counters. The channel architecture is optimized for the detector characteristics in order to achieve the best energy resolution at counting rates of up to 5 M counts/second. The amplifier shows a linear sensitivity of 118 mV/fC and an equivalent noise charge of about 711 e−, for a detector capacitance of 5 pF. Complete evaluation of the circuit is presented using electronic pulses and pixel detectors.

  17. Effect of a biological activated carbon filter on particle counts

    Institute of Scientific and Technical Information of China (English)

    Su-hua WU; Bing-zhi DONG; Tie-jun QIAO; Jin-song ZHANG

    2008-01-01

    Due to the importance of biological safety in drinking water quality and the disadvantages which exist in traditional methods of detecting typical microorganisms such as Cryptosporidium and Giardia,it is necessary to develop an alternative.Particle counts is a qualitative measurement of the amount of dissolved solids in water.The removal rate of particle counts was previously used as an indicator of the effectiveness of a biological activated carbon(BAC)filter in removing Cryptosporidium and Giardia.The particle counts in a BAC filter effluent over one operational period and the effects of BAC filter construction and operational parameters were investigated with a 10 m3/h pilot plant.The results indicated that the maximum particle count in backwash remnant water was as high as 1296 count/ml and it needed about 1.5 h to reduce from the maximum to less than 50 count/ml.During the standard filtration period,particle counts stay constant at less than 50 count/ml for 5 d except when influ-enced by sand filter backwash remnant water.The removal rates of particle counts in the BAC filter are related to characteristics of the carbon.For example,a columned carbon and a sand bed removed 33.3% and 8.5% of particles,respectively,while the particle counts in effluent from a cracked BAC filter was higher than that of the influent.There is no significant difference among particle removal rates with different filtration rates.High post-ozone dosage(>2 mg/L)plays an important role in particle count removal;when the dosage was 3 mg/L,the removal rates by carbon layers and sand beds decreased by 17.5% and increased by 9.5%,respectively,compared with a 2 mg/L dosage.

  18. Saturation and High Density QCD

    OpenAIRE

    Mueller, A. H.

    2005-01-01

    Recent progress in understanding general properties of high energy scattering near the unitarity limit, where high density gluon components of the wavefunction are dominant, is reviewed. The similarity of the QCD problem and that of reaction-diffusion processes in statistical physics is emphasized. The energy dependence of the saturation momentum and the status of geometric scaling are discussed.

  19. Resolved SZE Cluster Count

    Institute of Scientific and Technical Information of China (English)

    Jia-Yu Tang; Zu-Hui Fan

    2003-01-01

    We study the counts of resolved SZE (Sunyaev-Zel'dovich effect) clus-ters expected from an interferometric survey in different cosmological models underdifferent conditions. The self-similar universal gas model and Press-Schechter massfunction are used. We take the observing frequency to be 90 GHz, and consider twodish diameters, 1.2 m and 2.5 m. We calculate the number density of the galaxyclusters dN/(dΩdz) at a high flux limit Slimv = 100mJy and at a relative lowSlimv = 10 mJy. The total numbers of SZE clusters N in two low-Ω0 models arecompared. The results show that the influence of the resolved effect depends notonly on D, but also on Slimv: at a given D, the effect is more significant for a highthan for a low Slim Also, the resolved effect for a flat universe is more impressivethan that for an open universe. For D = 1.2m and Slimv= 10mJy, the resolvedeffect is very weak. Considering the designed interferometers which will be used tosurvey SZE clusters, we find that the resolved effect is insignificant when estimatingthe expected yield of the SZE cluster surveys.

  20. Multivariate ultrametric root counting

    CERN Document Server

    Avendano, Martin

    2011-01-01

    Let $K$ be a field, complete with respect to a discrete non-archimedian valuation and let $k$ be the residue field. Consider a system $F$ of $n$ polynomial equations in $K\\vars$. Our first result is a reformulation of the classical Hensel's Lemma in the language of tropical geometry: we show sufficient conditions (semiregularity at $w$) that guarantee that the first digit map $\\delta:(K^\\ast)^n\\to(k^\\ast)^n$ is a one to one correspondence between the solutions of $F$ in $(K^\\ast)^n$ with valuation $w$ and the solutions in $(k^\\ast)^n$ of the initial form system ${\\rm in}_w(F)$. Using this result, we provide an explicit formula for the number of solutions in $(K^\\ast)^n$ of a certain class of systems of polynomial equations (called regular), characterized by having finite tropical prevariety, by having initial forms consisting only of binomials, and by being semiregular at any point in the tropical prevariety. Finally, as a consequence of the root counting formula, we obtain the expected number of roots in $(K...

  1. Making environmental DNA count.

    Science.gov (United States)

    Kelly, Ryan P

    2016-01-01

    The arc of reception for a new technology or method--like the reception of new information itself--can pass through predictable stages, with audiences' responses evolving from 'I don't believe it', through 'well, maybe' to 'yes, everyone knows that' to, finally, 'old news'. The idea that one can sample a volume of water, sequence DNA out of it, and report what species are living nearby has experienced roughly this series of responses among biologists, beginning with the microbial biologists who developed genetic techniques to reveal the unseen microbiome. 'Macrobial' biologists and ecologists--those accustomed to dealing with species they can see and count--have been slower to adopt such molecular survey techniques, in part because of the uncertain relationship between the number of recovered DNA sequences and the abundance of whole organisms in the sampled environment. In this issue of Molecular Ecology Resources, Evans et al. (2015) quantify this relationship for a suite of nine vertebrate species consisting of eight fish and one amphibian. Having detected all of the species present with a molecular toolbox of six primer sets, they consistently find DNA abundances are associated with species' biomasses. The strength and slope of this association vary for each species and each primer set--further evidence that there is no universal parameter linking recovered DNA to species abundance--but Evans and colleagues take a significant step towards being able to answer the next question audiences tend to ask: 'Yes, but how many are there?'

  2. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  3. Counting Frequencies from Zotero Items

    Directory of Open Access Journals (Sweden)

    Spencer Roberts

    2013-04-01

    Full Text Available In Counting Frequencies you learned how to count the frequency of specific words in a list using python. In this lesson, we will expand on that topic by showing you how to get information from Zotero HTML items, save the content from those items, and count the frequencies of words. It may be beneficial to look over the previous lesson before we begin.

  4. Photon counting modules using RCA silicon avalanche photodiodes

    Science.gov (United States)

    Lightstone, Alexander W.; Macgregor, Andrew D.; Macsween, Darlene E.; Mcintyre, Robert J.; Trottier, Claude; Webb, Paul P.

    1989-01-01

    Avalanche photodiodes (APD) are excellent small area, solid state detectors for photon counting. Performance possibilities include: photon detection efficiency in excess of 50 percent; wavelength response from 400 to 1000 nm; count rate to 10 (exp 7) counts per sec; afterpulsing at negligible levels; timing resolution better than 1 ns. Unfortunately, these performance levels are not simultaneously available in a single detector amplifier configuration. By considering theoretical performance predictions and previous and new measurements of APD performance, the anticipated performance of a range of proposed APD-based photon counting modules is derived.

  5. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  6. 丙泊酚在无痛上消化道内镜检查术中对血氧饱和度的影响%Effect of Propofol on heart rate and saturation of blood oxygen during upper gastrointestinal endoscopy examination

    Institute of Scientific and Technical Information of China (English)

    吴明; 霍惠峰; 周家华; 陈英良

    2011-01-01

    Objective To study the effect of Propofol on the saturation decline of blood oxygen in upper gastrointestinal endoscopy examination and the reason of decline. Methods Two hundred patients (103 men and 97 women) having received upper gastrointestinal endoscopy examination due to various reasons enrolled in this study. Anamnesis and anthropometric values of the patients were taken.Preoperative oxygen saturation, hemoglobin levels and heart rate were recorded. Patients with initial oxygen saturation level <90% were excluded. Patients were divided into two groups. The first group included 100 patients, who underwent endoscopic examination without sedation and the second group included 100 patients, who underwent endoscopic examination propofol 1~ 2mg/(kg · h-1) for sedation. Patients' oxygen saturation and heart rate were monitored from the oropharyngeal anesthesia sedation before the start till 1 minute after the operation. During the endoscopic examination, minimum oxygen saturation and maximum heart rate values were recorded. The duration of the oxygen saturation <90% was recorded throughout the procedure to determine the stage of endoscopy at that time.Results There were no differences between the 2 groups in body mass index, smoking, hemoglobin and basal maximum pulse rate, duration of endoscopy, minimum basal oxygen saturation, duration of hypoxia and time to hypoxia. Reduction of blood oxygen saturation had no relationship with gender,duration of the endoscopy, basal pulse rate and hemoglobin level, but it correlatied with smoking.Conclusion Propofol as a premedication is a reliable method for upper gastrointestinal endoscopy examination and does not produce additional risk of serious complications. However, smoking as a factor of oxygen saturation decrease should be taken into account in patients with upper gastrointestinal endoscopy.%目的 研究上消化道内镜术前使用丙泊酚进行镇静是否会导致氧饱和度下降,并分析导致氧

  7. Delayed system control in presence of actuator saturation

    Directory of Open Access Journals (Sweden)

    A. Mahjoub

    2014-09-01

    Full Text Available The paper is introducing a new design method for systems’ controllers with input delay and actuator saturations and focuses on how to force the system output to track a reference input not necessarily saturation-compatible. We propose a new norm based on the way we quantify tracking performance as a function of saturation errors found using the same norm. The newly defined norm is related to signal average power making possible to account for most common reference signals e.g. step, periodic. It is formally shown that, whatever the reference shape and amplitude, the achievable tracking quality is determined by a well defined reference tracking mismatch error. This latter depends on the reference rate and its compatibility with the actuator saturation constraint. In fact, asymptotic output-reference tracking is achieved in the presence of constraint-compatible step-like references.

  8. Correcting for accidental correlations in saturated avalanche photodiodes.

    Science.gov (United States)

    Grieve, J A; Chandrasekara, R; Tang, Z; Cheng, C; Ling, A

    2016-02-22

    In this paper we present a general method for estimating rates of accidental coincidence between a pair of single photon detectors operated within their saturation regimes. By folding the effects of recovery time of both detectors and the detection circuit into an "effective duty cycle" we are able to accomodate complex recovery behaviour at high event rates. As an example, we provide a detailed high-level model for the behaviour of passively quenched avalanche photodiodes, and demonstrate effective background subtraction at rates commonly associated with detector saturation. We show that by post-processing using the updated model, we observe an improvement in polarization correlation visibility from 88.7% to 96.9% in our experimental dataset. This technique will be useful in improving the signal-to-noise ratio in applications which depend on coincidence measurements, especially in situations where rapid changes in flux may cause detector saturation.

  9. Saturation of Van Allen's belts

    CERN Document Server

    Le Bel, E

    2002-01-01

    The maximum number of electrons that can be trapped in van Allen's belts has been evaluated at CEA-DAM more precisely than that commonly used in the space community. The modelization that we have developed allows to understand the disagreement (factor 50) observed between the measured and predicted electrons flux by US satellites and theory. This saturation level allows sizing-up of the protection on a satellite in case of energetic events. (authors)

  10. Reference counting for reversible languages

    DEFF Research Database (Denmark)

    Mogensen, Torben Ægidius

    2014-01-01

    deallocation. This requires the language to be linear: A pointer can not be copied and it can only be eliminated by deallocating the node to which it points. We overcome this limitation by adding reference counts to nodes: Copying a pointer to a node increases the reference count of the node and eliminating...

  11. Coinductive counting with weighted automata

    NARCIS (Netherlands)

    Rutten, J.J.M.M.

    2002-01-01

    A general methodology is developed to compute the solution of a wide variety of basic counting problems in a uniform way: (1) the objects to be counted are enumerated by means of an infinite weighted automaton; (2) the automaton is reduced by means of the quantitative notion of stream bisimulation;

  12. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease in disease-fighting cells ( ... a decrease in a certain type of white blood cell (neutrophil). The definition of low white blood cell ...

  13. SATURATED PICRIC ACID PREVENTS AUTOPHAGIA

    Directory of Open Access Journals (Sweden)

    V Rahimi-Movaghar

    2008-08-01

    Full Text Available "nThe dysesthesia and paresthesia that occurs in laboratory rats after spinal cord injury (SCI results in autophagia. This self-destructive behavior interferes with functional assessments in designed studies and jeopardizes the health of the injured rat. In this study, we evaluated role of saturated picric acid in the prevention of autophagia and self-mutilation. All rats were anesthetized with an intraperitoneal injection of a mixture of ketamine (100 mg/kg and xylazine (10 mg/kg for the SCI procedures. In the first 39 rats, no solution applied to the hind limbs, but in the next 26 cases, we smeared the saturated picric acid on the tail, lower extremities, pelvic, and abdomen of the rats immediately after SCI. In the rats without picric acid, 23 rats died following autophagia, but in the 26 rats with picric acid, there was no autophagia (P < 0.001. Picric acid side effects in skin and gastrointestinal signs such as irritation, redness and diarrhea were not seen in any rat. Saturated picric acid is a topical solution that if used appropriately and carefully, might be safe and effectively prevents autophagia and self-mutilation. When the solution is applied to the lower abdomen and limbs, we presume that its bitterness effectively prevents the rat from licking and biting the limb.

  14. Hanford whole body counting manual

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs.

  15. Computed neutron coincidence counting applied to passive waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, M.; Baeten, P.; De Boeck, W.; Carchon, R. [Nuclear Research Centre, Mol (Belgium)

    1997-11-01

    Neutron coincidence counting applied for the passive assay of fissile material is generally realised with dedicated electronic circuits. This paper presents a software based neutron coincidence counting method with data acquisition via a commercial PC-based Time Interval Analyser (TIA). The TIA is used to measure and record all time intervals between successive pulses in the pulse train up to count-rates of 2 Mpulses/s. Software modules are then used to compute the coincidence count-rates and multiplicity related data. This computed neutron coincidence counting (CNCC) offers full access to all the time information contained in the pulse train. This paper will mainly concentrate on the application and advantages of CNCC for the non-destructive assay of waste. An advanced multiplicity selective Rossi-alpha method is presented and its implementation via CNCC demonstrated. 13 refs., 4 figs., 2 tabs.

  16. Wholebody Radiation Counting System.

    Science.gov (United States)

    1985-05-01

    curves shown are for a Cesium 137 source and show that the OPAMP is achieving the multiplication of forty and that it is being operated in the non...voltage in the range of one to three volts. This was accomplished by using a Fairchild uA715 operational amplifier ( OPAMP ). This unit was selected...for its ability to operate at very high rates with little distortion. The Fairchild OPAMP has a slew rate of 400 volts per microsecond and the ability

  17. Counting pairs of faint galaxies

    CERN Document Server

    Woods, D; Richer, H B; Woods, David; Fahlman, Gregory G; Richer, Harvey B

    1995-01-01

    The number of close pairs of galaxies observed to faint magnitude limits, when compared to nearby samples, determines the interaction or merger rate as a function of redshift. The prevalence of mergers at intermediate redshifts is fundamental to understanding how galaxies evolve and the relative population of galaxy types. Mergers have been used to explain the excess of galaxies in faint blue counts above the numbers expected from no-evolution models. Using deep CFHT (I\\leq24) imaging of a ``blank'' field we find a pair fraction which is consistent with the galaxies in our sample being randomly distributed with no significant excess of ``physical'' close pairs. This is contrary to the pair fraction of 34\\%\\pm9\\% found by Burkey {\\it et al.} for similar magnitude limits and using an identical approach to the pair analysis. Various reasons for this discrepancy are discussed. Colors and morphologies of our close pairs are consistent with the bulk of them being random superpositions although, as indicators of int...

  18. 转移概率部分未知的随机Markov饱和切换系统的非脆弱镇定%Non-fragile stabilization for stochastic system with Markov switching under partly unknown transition rates and actuator saturation

    Institute of Scientific and Technical Information of China (English)

    刘殿军; 齐文海; 高宪文

    2015-01-01

    The problem of non-fragile stabilization for the stochastic system with Markovian switching under partly unknown transition rates and actuator saturation is considered . By employing the parameter-dependent Lyapunov methodology, the non-fragile state feedback controller is proposed to guarantee the stochastic stability of the resulting closed-loop saturated system. Based on the obtained results, sufficient conditions with LMI constraints are established to acquire the largest contraction invariant set in the mean square sense. Finally, an example is given to illustrate the effectiveness of the proposed method.%研究一类转移概率部分未知的随机Markov饱和切换系统的非脆弱镇定问题。基于参数依赖型Lyapunov函数,设计非脆弱状态反馈控制器以保证闭环饱和系统的随机稳定性,在此基础之上,通过求解线性矩阵不等式,得到均方意义下的最大不变吸引域。数值仿真验证了所提出方法的有效性。

  19. Seasonal variations of halite saturation in the Dead Sea

    Science.gov (United States)

    Sirota, Ido; Arnon, Ali; Lensky, Nadav G.

    2016-09-01

    Hypersaline lakes and seas were common in the past, precipitating thick evaporitic salt deposits. The only modern analogue for the paleolimnology of deep salt-saturated aquatic environments exists in the Dead Sea. In this study, we present new insights from the Dead Sea on the role of seasonal thermohaline stratification and water balance on the seasonal and depth variations of the degree of saturation of halite (salt) and the rate of halite growth along the water column. We developed methodologies to accurately determine the empirical degree of halite saturation of the lake based on high accuracy densitometry, and to quantify halite growth rate along the water column. During summer, the epilimnion is undersaturated and halite is dissolved, whereas during winter the entire water column is supersaturated and crystallizes halite. This result is not trivial because the variations in the water balance suggest the opposite; summer is associated with higher loss of water by evaporation from the lake compared to the winter. Hence, the thermal effect overcomes the hydrological balance effect and thus governs the seasonal saturation cycle. The hypolimnion is supersaturated with respect to halite and crystallizes throughout the year, with higher super saturation and higher crystallization rates during winter. During summer, simultaneous opposing environments coexist—an undersaturated epilimnion that dissolves halite and a supersaturated hypolimnion that crystallizes halite, which results in focusing of halite deposits in the deep hypolimnetic parts of the evaporitic basins and thinning the shallow epilimnetic deposits.

  20. Dark-count-less photon-counting x-ray computed tomography system using a YAP-MPPC detector

    Science.gov (United States)

    Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2012-10-01

    A high-sensitive X-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and a dark-count-less photon-counting CT system was developed. X-ray photons are detected using a YAP(Ce) [cerium-doped yttrium aluminum perovskite] single crystal scintillator and an MPPC (multipixel photon counter). Photocurrents are amplified by a high-speed current-voltage amplifier, and smooth event pulses from an integrator are sent to a high-speed comparator. Then, logical pulses are produced from the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The image contrast of gadolinium medium slightly fell with increase in lower-level voltage (Vl) of the comparator. The dark count rate was 0 cps, and the count rate for the CT was approximately 250 kcps.

  1. An analytical model of crater count equilibrium

    Science.gov (United States)

    Hirabayashi, Masatoshi; Minton, David A.; Fassett, Caleb I.

    2017-06-01

    Crater count equilibrium occurs when new craters form at the same rate that old craters are erased, such that the total number of observable impacts remains constant. Despite substantial efforts to understand this process, there remain many unsolved problems. Here, we propose an analytical model that describes how a heavily cratered surface reaches a state of crater count equilibrium. The proposed model formulates three physical processes contributing to crater count equilibrium: cookie-cutting (simple, geometric overlap), ejecta-blanketing, and sandblasting (diffusive erosion). These three processes are modeled using a degradation parameter that describes the efficiency for a new crater to erase old craters. The flexibility of our newly developed model allows us to represent the processes that underlie crater count equilibrium problems. The results show that when the slope of the production function is steeper than that of the equilibrium state, the power law of the equilibrium slope is independent of that of the production function slope. We apply our model to the cratering conditions in the Sinus Medii region and at the Apollo 15 landing site on the Moon and demonstrate that a consistent degradation parameterization can successfully be determined based on the empirical results of these regions. Further developments of this model will enable us to better understand the surface evolution of airless bodies due to impact bombardment.

  2. The origins of counting algorithms.

    Science.gov (United States)

    Cantlon, Jessica F; Piantadosi, Steven T; Ferrigno, Stephen; Hughes, Kelly D; Barnard, Allison M

    2015-06-01

    Humans' ability to count by verbally labeling discrete quantities is unique in animal cognition. The evolutionary origins of counting algorithms are not understood. We report that nonhuman primates exhibit a cognitive ability that is algorithmically and logically similar to human counting. Monkeys were given the task of choosing between two food caches. First, they saw one cache baited with some number of food items, one item at a time. Then, a second cache was baited with food items, one at a time. At the point when the second set was approximately equal to the first set, the monkeys spontaneously moved to choose the second set even before that cache was completely baited. Using a novel Bayesian analysis, we show that the monkeys used an approximate counting algorithm for comparing quantities in sequence that is incremental, iterative, and condition controlled. This proto-counting algorithm is structurally similar to formal counting in humans and thus may have been an important evolutionary precursor to human counting. © The Author(s) 2015.

  3. Saturation curves of parallel-plate ionization chambers

    Energy Technology Data Exchange (ETDEWEB)

    Fallone, B.G.; Podgorsak, E.B.

    A new analytical expression is presented to describe the full saturation curve of parallel-plate ionization chambers. In contrast to the presently known expressions, which hold only for the near saturation region, this empirically determined expression is in excellent agreement with measurements in the whole collection efficiency range from 0 to 1 for x-ray sources with effective energies from 20 to 150 keV and cobalt-60 gamma rays. The dependence of the ion collection efficiency and the extrapolated electric field, which is a parameter in the new saturation curve expression, on electric field, dose, dose rate, beam quality, and chamber volume, is discussed. The effect of photoemission from the chamber polarizing electrode for low-energy x-ray beams on the saturation current is demonstrated. A universal ionization chamber constant is derived experimentally. It is shown that all parameters of the saturation curve equation and thus the saturation curve itself, can be calculated from one single measurement of ionization current at a given electric field and air gap thickness.

  4. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    Trust in the correctness of an election outcome requires proof of the correctness of vote counting. By formalising particular voting protocols as rules, correctness of vote counting amounts to verifying that all rules have been applied correctly. A proof of the outcome of any particular election......-based formalisation of voting protocols inside a theorem prover, we synthesise vote counting programs that are not only provably correct, but also produce independently verifiable certificates. These programs are generated from a (formal) proof that every initial set of ballots allows to decide the election winner...

  5. White blood cell counting system

    Science.gov (United States)

    1972-01-01

    The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.

  6. Law of nonlinear flow in saturated clays and radial consolidation

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    It was derived that micro-scale amount level of average pore radius of clay changed from 0.01 to 0.1 micron by an equivalent concept of flow in porous media. There is good agreement between the derived results and test ones. Results of experiments show that flow in micro-scale pore of saturated clays follows law of nonlinear flow. Theoretical analyses demonstrate that an interaction of solid-liquid interfaces varies inversely with permeability or porous radius. The interaction is an important reason why nonlinear flow in saturated clays occurs. An exact mathematical model was presented for nonlinear flow in micro-scale pore of saturated clays. Dimension and physical meanings of parameters of it are definite. A new law of nonlinear flow in saturated clays was established. It can describe characteristics of flow curve of the whole process of the nonlinear flow from low hydraulic gradient to high one. Darcy law is a special case of the new law. A mathematical model was presented for consolidation of nonlinear flow in radius direction in saturated clays with constant rate based on the new law of nonlinear flow. Equations of average mass conservation and moving boundary, and formula of excess pore pressure distribution and average degree of consolidation for nonlinear flow in saturated clay were derived by using an idea of viscous boundary layer, a method of steady state in stead of transient state and a method of integral of an equation. Laws of excess pore pressure distribution and changes of average degree of consolidation with time were obtained. Results show that velocity of moving boundary decreases because of the nonlinear flow in saturated clay. The results can provide geology engineering and geotechnical engineering of saturated clay with new scientific bases. Calculations of average degree of consolidation of the Darcy flow are a special case of that of the nonlinear flow.

  7. Promoter analysis by saturation mutagenesis

    Directory of Open Access Journals (Sweden)

    Baliga Nitin

    2001-01-01

    Full Text Available Gene expression and regulation are mediated by DNA sequences, in most instances, directly upstream to the coding sequences by recruiting transcription factors, regulators, and a RNA polymerase in a spatially defined fashion. Few nucleotides within a promoter make contact with the bound proteins. The minimal set of nucleotides that can recruit a protein factor is called a cis-acting element. This article addresses a powerful mutagenesis strategy that can be employed to define cis-acting elements at a molecular level. Technical details including primer design, saturation mutagenesis, construction of promoter libraries, phenotypic analysis, data analysis, and interpretation are discussed.

  8. The Transverse Energy as a Barometer of a Saturated Plasma

    CERN Document Server

    Dumitru, A; Dumitru, Adrian; Gyulassy, Miklos

    2002-01-01

    The evolution of the gluon plasma produced with saturation initial conditions is calculated via Boltzmann transport theory for nuclear collisions at high energy. The saturation scale increases with the nuclear size and the beam energy, and thus we find that the perturbative rescattering rate decreases relative to the initial longitudinal expansion rate of the plasma. The effective longitudinal pressure remains significantly below the lattice QCD pressure until the plasma cools to near the confinement scale. Therefore, the transverse energy per unit of rapidity and its dependence on beam energy provides a sensitive test of gluon saturation models: the fractional transverse energy loss due to final state interactions is smaller and exhibits a weaker energy dependence than if ideal (nondissipative) hydrodynamics applied throughout the evolution.

  9. Gradient ascent pulse engineering for rapid exchange saturation transfer

    Science.gov (United States)

    Rancan, G.; Nguyen, T. T.; Glaser, S. J.

    2015-03-01

    Efforts in the clinical translation of the paraCEST contrast agent Yb-HPDO3A have prompted an investigation into saturation pulse optimality under energy constraints. The GRAPE algorithm has been adapted and implemented for saturation pulse optimization with chemical exchange. The flexibility of the methodology, both in extracting the microscopical parameter ensemble for the algorithm as well as in determining the characteristics of this new class of rising amplitude waveforms allows rapid testing and implementation. Optimal pulses achieve higher saturation efficiencies than the continuous wave gold standard for rapid and especially for variable exchange rates, as brought about by pH-catalysis. Gains of at least 5-15% without any tradeoff have been confirmed both on a spectrometer and on a clinical imager. Pool specific solutions, with pulses optimized for a specific exchange rate value, additionally increase the flexibility of the CEST ratiometric analysis. A simple experimental approach to determine close to optimal triangular pulses is presented.

  10. A simple model of eddy saturation

    Science.gov (United States)

    Marshall, D. P.; Ambaum, M.; Munday, D. R.; Novak, L.; Maddison, J. R.

    2016-02-01

    A simple model is developed for eddy saturation of the Antarctic Circumpolar Current (ACC): the relative insensitivity of its volume transport to the magnitude of the surface wind stress in ocean models with explicit eddies. The simple model solves prognostic equations for the ACC volume transport and the eddy energy, forming a 2-dimensional nonlinear dynamical system. In equilibrium, the volume transport is independent of the surface wind stress but scales with the bottom drag, whereas the eddy energy scales with the wind stress but is independent of bottom drag. The magnitude of the eddy energy is controlled by the zonal momentum balance between the surface wind stress and eddy form stress, whereas the baroclinic volume transport is controlled by the eddy energy balance between the mean-to-eddy energy conversion and bottom dissipation. The theoretical predictions are confirmed in eddy-resolving numerical calculations for an idealised reentrant channel. The results suggest that the rate of eddy energy dissipation has a strong impact not only the volume transport of the ACC, but also on global ocean stratification and heat content through the thermal wind relation. Moreover, a vital ingredient in this model is a relation between the eddy form stress and eddy energy derived in the eddy parameterisation framework of Marshall et al. (2012, J. Phys. Oceanogr.), offering the prospect of obtaining eddy saturation in ocean models with parameterised eddies.

  11. Are saturating pulses indeed saturating? Evidence for considerable PSII yield underestimation in leaves adapted to high levels of natural light.

    Science.gov (United States)

    Karageorgou, Panagiota; Tziortzis, Iakovos; Manetas, Yiannis

    2007-10-01

    The "saturating pulse" method of in vivo Chl fluorescence measurement has been widely used by physiologists and especially ecophysiologists, as it allows a simple, rapid and non-invasive assessment of PSII function and the allocation of absorbed energy into photochemical and non-photochemical processes. It is based on the accurate determination of the so-called Fm('), i.e. the fluorescence signal emitted when a "saturating" light pulse closes all PSII centers. In this methodological investigation, we examined whether the saturating pulse intensities required to obtain maximal fluorescence yields differ between leaves of various species receiving varying actinic light irradiances. It was shown that, in leaves adapted to comparatively high (yet realistic) levels of natural irradiances, the saturating pulses usually applied are not able to close all PSII reaction centers. As a result, there is a high risk of considerable Fm(') underestimation. Accordingly, the derived values of effective PSII yields and linear electron transport rates (ETR) are also underestimated, even at the highest saturation pulse levels afforded by commercial instruments. Since the extent of underestimation increases with actinic irradiance, the ETR versus light curves are considerably distorted. The possible reasons for the apparent inability of "saturating" pulses to close all PSII centers at high actinic light and the practical implications, especially in field work, are discussed.

  12. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  13. What Counts Most?

    DEFF Research Database (Denmark)

    Bagdziunaite, Dalia; Jensen, Anne Strande; Auning-Hansen, Julie

    2014-01-01

    of the relative strength of these effects, and how they may dynamically interact. To abate this problem, we conducted an experiment in which we recruited participants from three regions (Italy, France and rest of world), to undergo wine testing and rating of wine taste preference, and willingness to pay (WTP......) while being exposed to the CoO and price of each wine. Unbeknownst to the participants, they all tasted the same wine. To provide a better understanding of the underlying mechanisms of the observed effects, emotional arousal was assessed using pupillometry. Using a linear regression model, our results...... demonstrate that price and CoO individually have a significant effect on the hedonic experience of wine (R² = 0.11, p

  14. The Mayan Long Count Calendar

    OpenAIRE

    Chanier, Thomas

    2015-01-01

    The Maya were known for their astronomical proficiency. This is demonstrated in the Mayan codices where ritual practices were related to astronomical events/predictions. Whereas Mayan mathematics were based on a vigesimal system, they used a different base when dealing with long periods of time, the Long Count Calendar (LCC), composed of different Long Count Periods: the Tun of 360 days, the Katun of 7200 days and the Baktun of 144000 days. There were two other calendars used in addition to t...

  15. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  16. Saturated versus non-saturated two-scales permeability

    Science.gov (United States)

    Lopez, Elena; Ammar, Amine; Abisset-Chavanne, Emmanuelle; Binetruy, Christophe; Chinesta, Francisco

    2016-10-01

    A crucial step in many composites manufacturing processes is the impregnation of fibrous medium with the resin. The fundamental property needed to quantify the flow is the permeability of the fibrous medium. Process models require the permeability as input data to predict flow patterns and pressure fields. Efficient numerical techniques are needed to solve homogenization problems with geometrical data coming from high-resolution images, involving two-scales and linear fluids. Within this frame-work, this work addresses the question of how to compute the macroscopic permeability from a microscopic description consisting of a viscous fluid flow model defined in a two-scale porous medium, considering the saturated and unsaturated cases.

  17. 南极考察队员在不同高原环境下血氧饱和度及心率与高原反应风险的关系%Study of blood oxygen saturation, heart rate changes and plateau reaction of the Antarctic Kunlun station investigation team in different plateau environments

    Institute of Scientific and Technical Information of China (English)

    赵顺云; 吴新民; 郭亚民; 张树顺; 安艳明; 李冰; 王皓

    2013-01-01

    目的 探讨南极考察队员在不同高原环境下血氧饱和度、心率变化与高原反应风险的关系.方法 2010年8月至2011年4月采用无创性氧饱和度测定仪监测(MD300-C) 16名南极考察队员在不同海拔情况以及不同高原环境(西藏高原和南极高原)下的血氧饱和度和心率变化以及高原反应情况,根据Lake Louise Consensus急性高原反应症状评分和判定方法,判定急性高原反应的程度.结果 16名考察队员在我国海拔110、3650、4300 m时血氧饱和度、心率情况差异均有统计学意义[96.8%±1.2%、89.1%±1.2%、86.1%±2.0%,(75.0±5.4)次/min、(104.0±4.3)次/min、(113.0±5.2)次/min,F=214.155、240.088,均P<0.05].南极高原环境下不同海拔(2000、2500、3000、3500、4087 m)血氧饱和度、心率差异也均有统计学意义[91.9%±1.3%、90.5%±1.3%、87.6%±1.4%、85.0%±1.8%、81.5%±2.2%,(85.9±3.2)次/min、(90.6±2.8)次/min、(97.8±4.1)次/min、(102.0±3.4)次/min、(106.3±3.9)次/min,F=105.418、90.174,均P<0.05].在南极高原环境下氧饱和度、心率与Lake Louise Consensus急性高原病症状评分相关(r=-0.446、0.565,均P<0.05).结论 南极考察队员在西藏高原和南极高原不同海拔下血氧饱和度、心率有明显的变化,且随着海拔的升高,高原反应风险逐渐增加.%Objective To explore the blood oxygen saturation and heart rate changes of the Antarctic expeditioners.Methods During August 2010 to April 2011,the changes in blood oxygen saturation,heart rate and plateau reaction of 16 Antarctic expedition team in different plateau environments (Tibetan plateau versus Antarctic plateau) were monitored with the noninvasive pulse oximeter MD300-C.The extent of acute mountain sickness was determined according to the Lake Louise Consensus acute mountain reaction symptom scores and judgment method.Results The changes of blood oxygen saturation,heart rate at different altitudes

  18. The statistical distribution of the number of counted scintillation photons in digital silicon photomultipliers: model and validation.

    Science.gov (United States)

    van Dam, Herman T; Seifert, Stefan; Schaart, Dennis R

    2012-08-07

    In the design and application of scintillation detectors based on silicon photomultipliers (SiPMs), e.g. in positron emission tomography imaging, it is important to understand and quantify the non-proportionality of the SiPM response due to saturation, crosstalk and dark counts. A new type of SiPM, the so-called digital silicon photomultiplier (dSiPM), has recently been introduced. Here, we develop a model of the probability distribution of the number of fired microcells, i.e. the number of counted scintillation photons, in response to a given amount of energy deposited in a scintillator optically coupled to a dSiPM. Based on physical and functional principles, the model elucidates the statistical behavior of dSiPMs. The model takes into account the photon detection efficiency of the detector; the light yield, excess variance and time profile of the scintillator; and the crosstalk probability, dark count rate, integration time and the number of microcells of the dSiPM. Furthermore, relations for the expectation value and the variance of the number of fired cells are deduced. These relations are applied in the experimental validation of the model using a dSiPM coupled to a LSO:Ce,Ca scintillator. Finally, we propose an accurate method for the correction of energy spectra measured with dSiPM-based scintillation detectors.

  19. Modeling Outcomes of First-Line Antiretroviral Therapy and Rate of CD4 Counts Change among a Cohort of HIV/AIDS Patients in Ethiopia: A Retrospective Cohort Study.

    Science.gov (United States)

    Awoke, Tadesse; Worku, Alemayehu; Kebede, Yigzaw; Kasim, Adetayo; Birlie, Belay; Braekers, Roel; Zuma, Khangelani; Shkedy, Ziv

    2016-01-01

    Antiretroviral therapy has shown to be effective in reducing morbidity and mortality in patients infected with HIV for the past couples of decades. However, there remains a need to better understand the characteristics of long-term treatment outcomes in resource poor settings. The main aim of this study was to determine and compare the long-term response of patients on nevirapine and efavirenz based first line antiretroviral therapy regimen in Ethiopia. Hospital based retrospective cohort study was conducted from January 2009 to December 2013 at University hospital located in Northwest Ethiopia. Human subject research approval for this study was received from University of Gondar Research Ethics Committee and the medical director of the hospital. Cox-proportional hazards model was used to assess the effect of baseline covariates on composite outcome and a semi-parametric mixed effect model was used to investigate CD4 counts response to treatments. A total of 2386 HIV/AIDS naive patients were included in this study. Nearly one-in-four patients experienced the events, of which death, lost to follow up, treatment substitution and discontinuation of Non-Nucleoside Reverse Transcriptase Inhibitors(NNRTI) accounted: 99 (26.8%), 122 (33.0%), 137 (37.0%) and 12 (3.2%), respectively. The hazard of composite outcome on nevirapine compared with efavirenz was 1.02(95%CI: 0.52-1.99) with p-value = 0.96. Similarly, the hazard of composite outcome on tenofovir and stavudine compared with zidovudine were 1.87 (95%CI: 1.52-2.32), p-value HIV/AIDS patients in Ethiopia. There was significant difference on risk of composite outcome between patients who were initiated with Tenofovir containing ART regimen compared with zidovudine after controlling for NNRTI drug combinations.

  20. Direct calibration of click-counting detectors

    Science.gov (United States)

    Bohmann, M.; Kruse, R.; Sperling, J.; Silberhorn, C.; Vogel, W.

    2017-03-01

    We introduce and experimentally implement a method for the detector calibration of photon-number-resolving time-bin multiplexing layouts based on the measured click statistics of superconducting nanowire detectors. In particular, the quantum efficiencies, the dark count rates, and the positive operator-valued measures of these measurement schemes are directly obtained with high accuracy. The method is based on the moments of the click-counting statistics for coherent states with different coherent amplitudes. The strength of our analysis is that we can directly conclude—on a quantitative basis—that the detection strategy under study is well described by a linear response function for the light-matter interaction and that it is sensitive to the polarization of the incident light field. Moreover, our method is further extended to a two-mode detection scenario. Finally, we present possible applications for such well-characterized detectors, such as sensing of atmospheric loss channels and phase sensitive measurements.

  1. The use of saturation in qualitative research.

    Science.gov (United States)

    Walker, Janiece L

    2012-01-01

    Understanding qualitative research is an important component of cardiovascular nurses' practice and allows them to understand the experiences, stories, and perceptions of patients with cardiovascular conditions. In understanding qualitative research methods, it is essential that the cardiovascular nurse understands the process of saturation within qualitative methods. Saturation is a tool used for ensuring that adequate and quality data are collected to support the study. Saturation is frequently reported in qualitative research and may be the gold standard. However, the use of saturation within methods has varied. Hence, the purpose of this column is to provide insight for the cardiovascular nurse regarding the use of saturation by reviewing the recommendations for which qualitative research methods it is appropriate to use and how to know when saturation is achieved. In understanding saturation, the cardiovascular nurse can be a better consumer of qualitative research.

  2. An innovative method to reduce count loss from pulse pile-up in a photon-counting pixel for high flux X-ray applications

    Science.gov (United States)

    Lee, D.; Lim, K.; Park, K.; Lee, C.; Alexander, S.; Cho, G.

    2017-03-01

    In this study, an innovative fast X-ray photon-counting pixel for high X-ray flux applications is proposed. A computed tomography system typically uses X-ray fluxes up to 108 photons/mm2/sec at the detector and thus a fast read-out is required in order to process individual X-ray photons. Otherwise, pulse pile-up can occur at the output of the signal processing unit. These superimposed signals can distort the number of incident X-ray photons leading to count loss. To minimize such losses, a cross detection method was implemented in the photon-counting pixel. A maximum count rate under X-ray tube voltage of 90 kV was acquired which reflect electrical test results of the proposed photon counting pixel. A maximum count of 780 kcps was achieved with a conventional photon-counting pixel at the pulse processing time of 500 ns, which is the time for a pulse to return to the baseline from the initial rise. In contrast, the maximum count of about 8.1 Mcps was achieved with the proposed photon-counting pixel. From these results, it was clear that the maximum count rate was increased by approximately a factor 10 times by adopting the cross detection method. Therefore, it is an innovative method to reduce count loss from pulse pile-up in a photon-counting pixel while maintaining the pulse processing time.

  3. Photon Counting Using Edge-Detection Algorithm

    Science.gov (United States)

    Gin, Jonathan W.; Nguyen, Danh H.; Farr, William H.

    2010-01-01

    New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1

  4. Holographic Pomeron: Saturation and DIS

    CERN Document Server

    Stoffers, Alexander

    2012-01-01

    We briefly review the approach to dipole-dipole scattering in holographic QCD developed in ARXIV:1202.0831. The Pomeron is modeled by exchanging closed strings between the dipoles and yields Regge behavior for the elastic amplitude. We calculate curvature corrections to this amplitude in both a conformal and confining background, identifying the holographic direction with the virtuality of the dipoles. The it wee-dipole density is related to the string tachyon diffusion in both virtuality and the transverse directions. We give an explicit derivation of the dipole saturation momentum both in the conformal and confining metric. Our holographic result for the dipole-dipole cross section and the it wee-dipole density in the conformal limit are shown to be identical in form to the BFKL pomeron result when the non-critical string transverse dimension is $D_\\perp=3$. The total dipole-dipole cross section is compared to DIS data from HERA.

  5. Gain scheduled control of linear systems with unsymmetrical saturation actuators

    Science.gov (United States)

    Wu, Wen-Juan; Duan, Guang-Ren

    2016-11-01

    The problem of stabilisation of a class of nonlinear continuous-time systems with asymmetric saturations on the control is studied in this paper. By combining the parametric Lyapunov equation approach and gain scheduling technique, a state feedback gain scheduling controller is proposed to solve the stabilisation problem of systems with unsymmetrical saturated control. The proposed gain scheduled approach is to increase the value of the design parameter so that the convergence rate of the closed-loop system can be increased. Numerical simulations show the effectiveness of the proposed approach.

  6. Effect of point-of-care CD4 cell count tests on retention of patients and rates of antiretroviral therapy initiation in primary health clinics: an observational cohort study.

    Science.gov (United States)

    Jani, Ilesh V; Sitoe, Nádia E; Alfai, Eunice R; Chongo, Patrina L; Quevedo, Jorge I; Rocha, Beatriz M; Lehe, Jonathan D; Peter, Trevor F

    2011-10-29

    Loss to follow-up of HIV-positive patients before initiation of antiretroviral therapy can exceed 50% in low-income settings and is a challenge to the scale-up of treatment. We implemented point-of-care counting of CD4 cells in Mozambique and assessed the effect on loss to follow-up before immunological staging and treatment initiation. In this observational cohort study, data for enrolment into HIV management and initiation of antiretroviral therapy were extracted retrospectively from patients' records at four primary health clinics providing HIV treatment and point-of-care CD4 services. Loss to follow-up and the duration of each preparatory step before treatment initiation were measured and compared with baseline data from before the introduction of point-of-care CD4 testing. After the introduction of point-of-care CD4 the proportion of patients lost to follow-up before completion of CD4 staging dropped from 57% (278 of 492) to 21% (92 of 437) (adjusted odds ratio [OR] 0·2, 95% CI 0·15-0·27). Total loss to follow-up before initiation of antiretroviral treatment fell from 64% (314 of 492) to 33% (142 of 437) (OR 0·27, 95% CI 0·21-0·36) and the proportion of enrolled patients initiating antiretroviral therapy increased from 12% (57 of 492) to 22% (94 of 437) (OR 2·05, 95% CI 1·42-2·96). The median time from enrolment to antiretroviral therapy initiation reduced from 48 days to 20 days (pCD4 staging, which decreased from 32 days to 3 days (pantiretroviral therapy initiation did not change significantly (OR 0·84, 95% CI 0·49-1·45). Point-of-care CD4 testing enabled clinics to stage patients rapidly on-site after enrolment, which reduced opportunities for pretreatment loss to follow-up. As a result, more patients were identified as eligible for and initiated antiretroviral treatment. Point-of-care testing might therefore be an effective intervention to reduce pretreatment loss to follow-up. Absolute Return for Kids and UNITAID. Copyright © 2011 Elsevier

  7. Hanford whole body counting manual

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs.

  8. Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

    Science.gov (United States)

    Farr, William H.

    2009-01-01

    Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

  9. Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

    Science.gov (United States)

    Farr, William H.

    2009-01-01

    Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

  10. A new theoretical interpretation of Archie's saturation exponent

    Science.gov (United States)

    Glover, Paul W. J.

    2017-07-01

    This paper describes the extension of the concepts of connectedness and conservation of connectedness that underlie the generalized Archie's law for n phases to the interpretation of the saturation exponent. It is shown that the saturation exponent as defined originally by Archie arises naturally from the generalized Archie's law. In the generalized Archie's law the saturation exponent of any given phase can be thought of as formally the same as the phase (i.e. cementation) exponent, but with respect to a reference subset of phases in a larger n-phase medium. Furthermore, the connectedness of each of the phases occupying a reference subset of an n-phase medium can be related to the connectedness of the subset itself by Gi = GrefSini. This leads naturally to the idea of the term Sini for each phase i being a fractional connectedness, where the fractional connectednesses of any given reference subset sum to unity in the same way that the connectednesses sum to unity for the whole medium. One of the implications of this theory is that the saturation exponent of any phase can be now be interpreted as the rate of change of the fractional connectedness with saturation and connectivity within the reference subset.

  11. Modeling gradually changing seasonal variation in count data using state space models: a cohort study of hospitalization rates of stroke in atrial fibrillation patients in Denmark from 1977 to 2011.

    Science.gov (United States)

    Christensen, Anette L; Lundbye-Christensen, Søren; Overvad, Kim; Rasmussen, Lars H; Dethlefsen, Claus

    2012-11-20

    Seasonal variation in the occurrence of cardiovascular diseases has been recognized for decades. In particular, incidence rates of hospitalization with atrial fibrillation (AF) and stroke have shown to exhibit a seasonal variation. Stroke in AF patients is common and often severe. Obtaining a description of a possible seasonal variation in the occurrence of stroke in AF patients is crucial in clarifying risk factors for developing stroke and initiating prophylaxis treatment. Using a dynamic generalized linear model we were able to model gradually changing seasonal variation in hospitalization rates of stroke in AF patients from 1977 to 2011. The study population consisted of all Danes registered with a diagnosis of AF comprising 270,017 subjects. During follow-up, 39,632 subjects were hospitalized with stroke. Incidence rates of stroke in AF patients were analyzed assuming the seasonal variation being a sum of two sinusoids and a local linear trend. The results showed that the peak-to-trough ratio decreased from 1.25 to 1.16 during the study period, and that the times of year for peak and trough changed slightly. The present study indicates that using dynamic generalized linear models provides a flexible modeling approach for studying changes in seasonal variation of stroke in AF patients and yields plausible results.

  12. VersaCount: customizable manual tally software for cell counting

    Directory of Open Access Journals (Sweden)

    DeRisi Joseph L

    2010-01-01

    Full Text Available Abstract Background The manual counting of cells by microscopy is a commonly used technique across biological disciplines. Traditionally, hand tally counters have been used to track event counts. Although this method is adequate, there are a number of inefficiencies which arise when managing large numbers of samples or large sample sizes. Results We describe software that mimics a traditional multi-register tally counter. Full customizability allows operation on any computer with minimal hardware requirements. The efficiency of counting large numbers of samples and/or large sample sizes is improved through the use of a "multi-count" register that allows single keystrokes to correspond to multiple events. Automatically updated multi-parameter values are implemented as user-specified equations, reducing errors and time required for manual calculations. The user interface was optimized for use with a touch screen and numeric keypad, eliminating the need for a full keyboard and mouse. Conclusions Our software provides an inexpensive, flexible, and productivity-enhancing alternative to manual hand tally counters.

  13. High quantum efficiency S-20 photocathodes for photon counting applications

    CERN Document Server

    Orlov, Dmitry A; Pinto, Serge Duarte; Glazenborg, Rene; Kernen, Emilie

    2016-01-01

    Based on conventional S-20 processes, a new series of high quantum efficiency (QE) photocathodes has been developed that can be specifically tuned for use in the ultraviolet, blue or green regions of the spectrum. The QE values exceed 30% at maximum response, and the dark count rate is found to be as low as 30 Hz/cm2 at room temperature. This combination of properties along with a fast temporal response makes these photocathodes ideal for application in photon counting detectors.

  14. The Origins of Counting Algorithms

    OpenAIRE

    Cantlon, Jessica F.; Piantadosi, Steven T.; Ferrigno, Stephen; Hughes, Kelly D.; Allison M Barnard

    2015-01-01

    Humans’ ability to ‘count’ by verbally labeling discrete quantities is unique in animal cognition. The evolutionary origins of counting algorithms are not understood. We report that non-human primates exhibit a cognitive ability that is algorithmically and logically similar to human counting. Monkeys were given the task of choosing between two food caches. Monkeys saw one cache baited with some number of food items, one item at a time. Then, a second cache was baited with food items, one at a...

  15. Tree modules and counting polynomials

    CERN Document Server

    Kinser, Ryan

    2011-01-01

    We give a formula for counting tree modules for the quiver S_g with g loops and one vertex in terms of tree modules on its universal cover. This formula, along with work of Helleloid and Rodriguez-Villegas, is used to show that the number of d-dimensional tree modules for S_g is polynomial in g with the same degree and leading coefficient as the counting polynomial A_{S_g}(d, q) for absolutely indecomposables over F_q, evaluated at q=1.

  16. Simulation of Partially Saturated - Saturated Flow in the Caspar Creek E-Road Groundwater System

    Science.gov (United States)

    Fisher, J.; Fisher, J.

    2001-12-01

    Over the past decade, the U.S. Forest Service has monitored the subsurface hillslope flow of the E-Road swale. The swale is located in the Caspar Creek watershed near Fort Bragg, California. In hydrologic year 1990 a logging road was built across the middle section of the hillslope followed by a total clearcut of the area during the following year. Development of the logging road has resulted in a large build up of subsurface waters upslope of the road. The increase in pore pressures behind the road is of major concern for slope stability and road failure. A conceptual model is developed to describe the movement of water within the E-Road groundwater system. The two-dimensional SUTRA model is used to describe both saturated and partially saturated flow within the system. SUTRA utilizes a finite element and integrated finite difference method to approximate the governing equation for flow. The model appears to reproduce the uniquely different frequency responses within the E-Road groundwater system. A comparison of simulated and historical piezometric responses demonstrates the model's inability to reproduce historical drainage rates. The low rates of simulated drainage are attributed to the absence of pipeflow within the model. Finally, road consolidation is associated with increased water pressures beneath the road bed.

  17. Power flow control using distributed saturable reactors

    Energy Technology Data Exchange (ETDEWEB)

    Dimitrovski, Aleksandar D.

    2016-02-13

    A magnetic amplifier includes a saturable core having a plurality of legs. Control windings wound around separate legs are spaced apart from each other and connected in series in an anti-symmetric relation. The control windings are configured in such a way that a biasing magnetic flux arising from a control current flowing through one of the plurality of control windings is substantially equal to the biasing magnetic flux flowing into a second of the plurality of control windings. The flow of the control current through each of the plurality of control windings changes the reactance of the saturable core reactor by driving those portions of the saturable core that convey the biasing magnetic flux in the saturable core into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the saturable core.

  18. Implications of carbon saturation model structure for simulated nitrogen mineralization dynamics

    Directory of Open Access Journals (Sweden)

    C. M. White

    2014-06-01

    Full Text Available Carbon (C saturation theory suggests that soils have a~limited capacity to stabilize organic C and that this capacity may be regulated by intrinsic soil properties such as clay content and mineralogy. While C saturation theory has advanced our ability to predict soil C stabilization, we only have a weak understanding of how C saturation affects N cycling. In biogeochemical models, C and N cycling are tightly coupled, with C decomposition and respiration driving N mineralization. Thus, changing model structures from non-saturation to C saturation dynamics can change simulated N dynamics. Carbon saturation models proposed in the literature calculate a theoretical maximum C storage capacity of saturating pools based on intrinsic soil properties, such as clay content. The extent to which current C stocks fill the storage capacity of the pool is termed the C saturation ratio, and this ratio is used to regulate either the efficiency or the rate of C transfer from donor to receiving pools. In this study, we evaluated how the method of implementing C saturation and the number of pools in a model affected net N mineralization from decomposing plant residues. In models that use the C saturation ratio to regulate transfer efficiency, C saturation affected N mineralization, while in those in which the C saturation ratio regulates transfer rates, N mineralization was independent of C saturation. When C saturation ratio regulates transfer efficiency, as the saturation ratio increases, the threshold C : N ratio at which positive net N mineralization occurs also increases because more of the C in the residue is respired. In a single-pool model where C saturation ratio regulated the transfer efficiency, predictions of N mineralization from residue inputs were unrealistically high, missing the cycle of N immobilization and mineralization typically seen after the addition of high C : N inputs to soils. A more realistic simulation of N mineralization was achieved

  19. Asymmetry in the effect of magnetic field on photon detection and dark counts in bended nanostrips

    CERN Document Server

    Semenov, A; Lusche, R; Ilin, K; Siegel, M; Hubers, H -W; Bralovic, N; Dopf, K; Vodolazov, D Yu

    2015-01-01

    Current crowding in the bends of superconducting nano-structures not only restricts measurable critical current in such structures but also redistributes local probabilities for dark and light counts to appear. Using structures from strips in the form of a square spiral which contain bends with the very same curvature with respect to the directions of bias current and external magnetic field, we have shown that dark counts as well as light count at small photon energies originate from areas around the bends. The minimum in the rate of dark counts reproduces the asymmetry of the maximum critical current density as function of the magnetic field. Contrary, the minimum in the rate of light counts demonstrate opposite asymmetry. The rate of light counts become symmetric at large currents and fields. Comparing locally computed absorption probabilities for photons and the simulated threshold detection current we found approximate location of areas near bends which deliver asymmetric light counts. Any asymmetry is a...

  20. PNN饱和度测井技术在大港油田的应用%Study on PNN saturation log and its application in Dagang Oilfield

    Institute of Scientific and Technical Information of China (English)

    胡玲妹; 刘存辉; 徐建平; 蒋华; 张宗亮

    2009-01-01

    为了对PNN饱和度测井技术影响因素有深入的认识和拓宽PNN测井应用范围,利用蒙特卡罗方法(MCNP)做模拟研究,进行了孔隙度、矿化度、含油饱和度、井眼等因素对计数率的影响研究、PNN饱和度测井同脉冲中子-伽马测井对比研究以及PNN测井确定孔隙度的理论研究,分别给出了:不同因素对热中子计数率的具体影响结果,PNN饱和度测井同脉冲中子-伽马测井相比具有一定的优越性;不同因素条件下孔隙度的确定公式.在大港油田的实际应用表明,该项测井技术在判断水淹层,寻找潜力层和未动用层,有效识别气层,识别低阻油层,定量计算地层含油饱和度、中子孔隙度,定性识别岩性等地质应用方面发挥着重要作用.%Aimed on further understanding of the influencing factors for PNN saturation log, and widening the application of this technology, the influencing of factors, such as porosity, salinity, borehole on count rate were studied through MCNP simulation. The PNN saturation logging was also contrasted with pulse neutron-gamma logging. The theory for porosity defi-nition by PNN saturation log was researched. The influences of different factors on thermal neutron count rate have been shown. Compared to pulse neutron-gamma logging, PNN saturation logging has special advantages. The formula for definition of porosity at different conditions was proposed. The application of the technology in Dagang Oil Field showed that it had a se-ries functions in geological application, such as flooded area determination, remaining oil layers seek, gas layer recognition, low resistivity recognition, quantitatively calculation of oil saturation, porosity determination by neutron, lithology distinguish, etc.

  1. Partially saturated granular column collapse

    Science.gov (United States)

    Turnbull, Barbara; Johnson, Chris

    2017-04-01

    Debris flows are gravity-driven sub-aerial mass movements containing water, sediments, soil and rocks. These elements lead to characteristics common to dry granular media (e.g. levee formation) and viscous gravity currents (viscous fingering and surge instabilities). The importance of pore fluid in these flows is widely recognised, but there is significant debate over the mechanisms of build up and dissipation of pore fluid pressure within debris flows, and the resultant effect this has on dilation and mobility of the grains. Here we specifically consider the effects of the liquid surface in the flow. We start with a simple experiment constituting a classical axisymmetric granular column collapse, but with fluid filling the column up to a depth comparable to the depth of grains. Thus, as the column collapses, capillary forces may be generated between the grains that prevent dilation. We explore a parameter space to uncover the effects of fluid viscosity, particle size, column size, aspect ratio, grain shape, saturation level, initial packing fraction and significantly, the effects of fine sediments in suspension which can alter the capillary interaction between wetted macroscopic grains. This work presents an initial scaling analysis and attempts to relate the findings to current debris flow modelling approaches.

  2. Casimir experiments showing saturation effects

    CERN Document Server

    Sernelius, Bo E

    2009-01-01

    We address several different Casimir experiments where theory and experiment disagree. First out is the classical Casimir force measurement between two metal half spaces; here both in the form of the torsion pendulum experiment by Lamoreaux and in the form of the Casimir pressure measurement between a gold sphere and a gold plate as performed by Decca et al.; theory predicts a large negative thermal correction, absent in the high precision experiments. The third experiment is the measurement of the Casimir force between a metal plate and a laser irradiated semiconductor membrane as performed by Chen et al.; the change in force with laser intensity is larger than predicted by theory. The fourth experiment is the measurement of the Casimir force between an atom and a wall in the form of the measurement by Obrecht et al. of the change in oscillation frequency of a 87 Rb Bose-Einstein condensate trapped to a fused silica wall; the change is smaller than predicted by theory. We show that saturation effects can exp...

  3. VERTICAL VIBRATION ANALYSIS OF AXISYMMETRIC SATURATED SOIL

    Institute of Scientific and Technical Information of China (English)

    CAI Yuan-qiang; XU Chang-jie; ZHENG Zao-feng; WU Da-zhi

    2006-01-01

    Based on Biot's dynamic consolidation equations, by means of Laplace-Hankel transform technology, the integral solutions of stress and displacement in saturated soil with subjacent rock-stratum under axisymmetric arbitrary excitations were derived. Influence of the reflected wave generated by the boundary was revealed. Numerical results indicate that the vibration frequency has some effect on the vertical displacement of saturated soil. The vertical displacement at the surface of saturated soil lags in phase with the load. Furthermore, the dynamic permeability coefficient of saturated soil has significant effect on the vertical displacement at the initial stage of load applied, but when the load becomes stable, the effect is inapparent.

  4. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N; Nielen, M; Lipman, L. J. A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  5. Nitrogen Saturation in Highly Retentive Watersheds?

    Science.gov (United States)

    Daley, M. L.; McDowell, W. H.

    2009-12-01

    Watershed managers are often concerned with minimizing the amount of N delivered to N-limited estuaries and coastal zones. A major concern is that watersheds might reach N saturation, in which N delivered to coastal zones increases due to declines in the efficiency of N retention despite constant or even reduced N inputs. We have quantified long-term changes in N inputs (atmospheric deposition, imported food and agricultural fertilizers), outputs (N concentration and export) and retention in the urbanizing Lamprey River watershed in coastal NH. Overall, the Lamprey watershed is 70% forested, receives about 13.5 kg N/ha/yr and has a high rate of annual N retention (85%). Atmospheric deposition (8.7 kg/ha/yr) is the largest N input to the watershed. Of the 2.2 kg N/ha/yr exported in the Lamprey River, dissolved organic N (DON) is the dominant form (50% of total) and it varies spatially throughout the watershed with wetland cover. Nitrate accounts for 30% of the N exported, shows a statistically significant increase from 1999 to 2009, and its spatial variability in both concentration and export is related to human population density. In sub-basins throughout the Lamprey, inorganic N retention is high (85-99%), but the efficiency of N retention declines sharply with increased human population density and associated anthropogenic N inputs. N assimilation in the vegetation, denitrification to the atmosphere and storage in the groundwater pool could all be important contributors to the current high rates of N retention. The temporal and spatial patterns that we have observed in nitrate concentration and export are driven by increases in N inputs and impervious surfaces over time, but the declining efficiency of N retention suggests that the watershed may also be reaching N saturation. The downstream receiving estuary, Great Bay, already suffers from low dissolved oxygen levels and eelgrass loss in part due to N loading from the Lamprey watershed. Targeting and reducing

  6. KIDS COUNT New Hampshire, 2000.

    Science.gov (United States)

    Shemitz, Elllen, Ed.

    This Kids Count report presents statewide trends in the well-being of New Hampshire's children. The statistical report is based on 22 indicators of child well-being in 5 interrelated areas: (1) children and families (including child population, births, children living with single parent, and children experiencing parental divorce); (2) economic…

  7. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  8. Verbal Counting in Bilingual Contexts

    Science.gov (United States)

    Donevska-Todorova, Ana

    2015-01-01

    Informal experiences in mathematics often include playful competitions among young children in counting numbers in as many as possible different languages. Can these enjoyable experiences result with excellence in the formal processes of education? This article discusses connections between mathematical achievements and natural languages within…

  9. Shakespeare Live! and Character Counts.

    Science.gov (United States)

    Brookshire, Cathy A.

    This paper discusses a live production of Shakespeare's "Macbeth" (in full costume but with no sets) for all public middle school and high school students in Harrisonburg and Rockingham, Virginia. The paper states that the "Character Counts" issues that are covered in the play are: decision making, responsibility and…

  10. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  11. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree discriminant. T

  12. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  13. Saturation effects in heterodyne detection with Geiger-mode InGaAs avalanche photodiode detector arrays.

    Science.gov (United States)

    Luu, Jane X; Jiang, Leaf A

    2006-06-01

    We report, to the best of our knowledge, the first demonstration of heterodyne detection of a glint target using an InGaAs avalanche photodiode detector (APD) array in the Geiger mode. Due to the finite number of pixels, all such photon-counting arrays necessarily suffer from saturation effects. At large photon fluxes, saturation of the APD degrades the Doppler frequency resolution and the signal-to-noise ratio (SNR). We derive analytical expressions for the Doppler resolution and SNR, taking saturation effects into account. The optimal local oscillator power can be obtained numerically from the SNR expression.

  14. Teaching Emotionally Disturbed Students to Count Feelings.

    Science.gov (United States)

    Bartels, Cynthia S.; Calkin, Abigail B.

    The paper describes a program to teach high school students with emotional and behavior problems to count their feelings, thereby improving their self concept. To aid in instruction, a hierarchy was developed which involved four phases: counting tasks completed and tasks not completed, counting independent actions in class, counting perceptions of…

  15. Does the Hall Effect Solve the Flux Pileup Saturation Problem?

    Science.gov (United States)

    Dorelli, John C.

    2010-01-01

    It is well known that magnetic flux pileup can significantly speed up the rate of magnetic reconnection in high Lundquist number resistive MHD,allowing reconnection to proceed at a rate which is insensitive to the plasma resistivity over a wide range of Lundquist number. Hence, pileup is a possible solution to the Sweet-Parker time scale problem. Unfortunately, pileup tends to saturate above a critical value of the Lundquist number, S_c, where the value ofS_c depends on initial and boundary conditions, with Sweet-Parker scaling returning above S_c. It has been argued (see Dorelli and Bim [2003] and Dorelli [2003]) that the Hall effect can allow flux pileup to saturate (when the scale of the current sheet approaches ion inertial scale, di) before the reconnection rate begins to stall. However, the resulting saturated reconnection rate, while insensitive to the plasma resistivity, was found to depend strongly on the di. In this presentation, we revisit the problem of magnetic island coalescence (which is a well known example of flux pileup reconnection), addressing the dependence of the maximum coalescence rate on the ratio of di in the "large island" limit in which the following inequality is always satisfied: l_eta di lambda, where I_eta is the resistive diffusion length and lambda is the island wavelength.

  16. DYNAMIC EFFECTIVE SHEAR STRENGTH OF SATURATED SAND

    Institute of Scientific and Technical Information of China (English)

    邵生俊; 谢定义

    2002-01-01

    The dynamic effective shear strength of saturated sand under cyclic loading is discussed in this paper. The discussion includes the transient time dependency behaviors based on the analysis of the results obtained in conventional cyclic triaxial tests and cyclic torsional shear triaxial tests. It has been found that the dynamic effective shear strength is composed of effective frictional resistance and viscous resistance, which are characterized by the strain rate dependent feature of strength magnitude, the coupling of consolidation stress with cyclic stress and the dependency of time needed to make the soil strength suffciently mobilized, and can also be expressed by the extended Mohr-Coulomb's law. The two strength parameters of the dynamic effective internal frictional angle φd and the dynamic viscosity coefficient η are determined. The former is unvaried for different number of cyclic loading, dynamic stress form and consolidation stress ratio. And the later is unvaried for the different dynamic shear strain rate γt developed during the sand liquefaction, but increases with the increase of initial density of sand. The generalization of dynamic effective stress strength criterion in the 3-dimensional effective stress space is studied in detail for the purpose of its practical use.

  17. Leucograma, proteína C reativa, alfa-1 glicoproteína ácida e velocidade de hemossedimentação na apendicite aguda Leucocyte count, C reactive protein, alpha-1 acid glycoprotein and erithrocyte sedimmentation rate in acute appendicitis

    Directory of Open Access Journals (Sweden)

    Bruno Ramalho de Carvalho

    2003-03-01

    ína ácida e velocidade de hemossedimentação mostraram-se pouco sensíveis e específicos. CONCLUSÕES: O leucograma e a proteína C reativa apresentam-se alterados de forma significativa nos casos de apendicite aguda, independentemente do sexo ou da faixa etária. O leucograma e, principalmente, a proteína C reativa devem ser exames considerados em indivíduos com tempo de evolução sintomática superior a 24 horas. Valores aumentados, entretanto, devem ser somados e não substituir a avaliação clínica do médico examinador. Dosagens de velocidade de hemossedimentação e da alfa-1 glicoproteína ácida não trazem auxílio ao diagnóstico da apendicite aguda.BACKGROUND: The diagnosis of acute appendicitis is clinic, but in some cases, it can present unusual symptoms. The diagnostic difficulties still lead surgeons to unnecessary laparotomies, which reach rates from 15% to 40%. Laboratory exams, then, may become important to complement appendicitis diagnosis. The leucocyte count seems to be the most important value, but measurement of acute phase proteins, specially, the C-reactive protein, is object of several studies. PATIENTS AND METHODS: This was a prospective study, involving 63 patients submitted to appendecectomies for acute appendicitis suspicion, in "Hospital das Clínicas", Federal University of Uberlândia, MG, Brazil, in whose blood were made dosages of acute phase proteins and the leucocyte count. RESULTS: The sample was composed by 44 male and 19 female patients, and the majority of them was between 11 and 30 years of age. The flegmonous type was the most freqüent (52.4%. The leucocyte count was altered in 74.6% of the cases and C-reactive protein elevation was observed in 88.9%. The alfa-1 acid glycoprotein and the erithrocyte sedimmentation rate were predominantly normal. The C-reactive protein was augmented in more than 80% of the cases in all ages. Leucocyte count and C-reactive protein were altered in 80% of the patients with the limit of 24

  18. Predictive Model Assessment for Count Data

    Science.gov (United States)

    2007-09-05

    critique count regression models for patent data, and assess the predictive performance of Bayesian age-period-cohort models for larynx cancer counts...the predictive performance of Bayesian age-period-cohort models for larynx cancer counts in Germany. We consider a recent suggestion by Baker and...Figure 5. Boxplots for various scores for patent data count regressions. 11 Table 1 Four predictive models for larynx cancer counts in Germany, 1998–2002

  19. Using X-ray computed tomography to evaluate the initial saturation resulting from different saturation procedures

    DEFF Research Database (Denmark)

    Christensen, Britt Stenhøj Baun; Wildenschild, D; Jensen, K.H.

    2006-01-01

    with pressurized nitrogen between each saturation and allowed to saturate for the same length of time for all the different procedures. Both gravimetric measurements and CT attenuation levels showed that venting the sample with carbon dioxide prior to saturation clearly improved initial saturation whereas the use...... saturation. In this study three techniques often applied in the laboratory have been evaluated for a fine sand sample: (1) venting of the sample with carbon dioxide prior to saturation, (2) applying vacuum to the sample in the beginning of the saturation procedure, and finally (3) the use of degassed water...... the sample was scanned in 1 mm intervals over the height of the 3.5 cm tall sample, providing detailed information on the performance of the different procedures. Five different combinations of the above mentioned saturation procedures were applied to a disturbed silica sand sample. The sample was drained...

  20. Interpreting HSE Contents of Planetary Basalts: The Importance of Sulfide Saturation and Under-Saturation

    Science.gov (United States)

    Righter, K.

    2000-01-01

    Highly siderophile elements provide important constraints on planetary differentiation due to their siderophile behavior. Their interpretation in terms of planetary differentiation models has so far overlooked the importance of sulfide saturation and under-saturation.

  1. Ultrafast THz Saturable Absorption in Semiconductors

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Hoffmann, Matthias C.

    2011-01-01

    We demonstrate THz saturable absorption in n-doped semiconductors GaAs, GaP, and Ge in a nonlinear THz time-domain spectroscopy experiment. Saturable absorption is caused by sample conductivity modulation due to electron heating and satellite valley scattering in the field of a strong THz pulse....

  2. Saturated fat, carbohydrate, and cardiovascular disease.

    Science.gov (United States)

    Siri-Tarino, Patty W; Sun, Qi; Hu, Frank B; Krauss, Ronald M

    2010-03-01

    A focus of dietary recommendations for cardiovascular disease (CVD) prevention and treatment has been a reduction in saturated fat intake, primarily as a means of lowering LDL-cholesterol concentrations. However, the evidence that supports a reduction in saturated fat intake must be evaluated in the context of replacement by other macronutrients. Clinical trials that replaced saturated fat with polyunsaturated fat have generally shown a reduction in CVD events, although several studies showed no effects. An independent association of saturated fat intake with CVD risk has not been consistently shown in prospective epidemiologic studies, although some have provided evidence of an increased risk in young individuals and in women. Replacement of saturated fat by polyunsaturated or monounsaturated fat lowers both LDL and HDL cholesterol. However, replacement with a higher carbohydrate intake, particularly refined carbohydrate, can exacerbate the atherogenic dyslipidemia associated with insulin resistance and obesity that includes increased triglycerides, small LDL particles, and reduced HDL cholesterol. In summary, although substitution of dietary polyunsaturated fat for saturated fat has been shown to lower CVD risk, there are few epidemiologic or clinical trial data to support a benefit of replacing saturated fat with carbohydrate. Furthermore, particularly given the differential effects of dietary saturated fats and carbohydrates on concentrations of larger and smaller LDL particles, respectively, dietary efforts to improve the increasing burden of CVD risk associated with atherogenic dyslipidemia should primarily emphasize the limitation of refined carbohydrate intakes and a reduction in excess adiposity.

  3. Saturated fat, carbohydrate, and cardiovascular disease1234

    Science.gov (United States)

    Siri-Tarino, Patty W; Sun, Qi; Hu, Frank B; Krauss, Ronald M

    2010-01-01

    A focus of dietary recommendations for cardiovascular disease (CVD) prevention and treatment has been a reduction in saturated fat intake, primarily as a means of lowering LDL-cholesterol concentrations. However, the evidence that supports a reduction in saturated fat intake must be evaluated in the context of replacement by other macronutrients. Clinical trials that replaced saturated fat with polyunsaturated fat have generally shown a reduction in CVD events, although several studies showed no effects. An independent association of saturated fat intake with CVD risk has not been consistently shown in prospective epidemiologic studies, although some have provided evidence of an increased risk in young individuals and in women. Replacement of saturated fat by polyunsaturated or monounsaturated fat lowers both LDL and HDL cholesterol. However, replacement with a higher carbohydrate intake, particularly refined carbohydrate, can exacerbate the atherogenic dyslipidemia associated with insulin resistance and obesity that includes increased triglycerides, small LDL particles, and reduced HDL cholesterol. In summary, although substitution of dietary polyunsaturated fat for saturated fat has been shown to lower CVD risk, there are few epidemiologic or clinical trial data to support a benefit of replacing saturated fat with carbohydrate. Furthermore, particularly given the differential effects of dietary saturated fats and carbohydrates on concentrations of larger and smaller LDL particles, respectively, dietary efforts to improve the increasing burden of CVD risk associated with atherogenic dyslipidemia should primarily emphasize the limitation of refined carbohydrate intakes and a reduction in excess adiposity. PMID:20089734

  4. Saturation and geometrical scaling in small systems

    CERN Document Server

    Praszalowicz, Michal

    2016-01-01

    Saturation and geometrical scaling (GS) of gluon distributions are a consequence of the non-linear evolution equations of QCD. We argue that in pp GS holds for the inelastic cross-section rather than for the multiplicity distributions. We also discuss possible fluctuations of the proton saturation scale in pA collisions at the LHC.

  5. Seismic determination of saturation in fractured reservoirs

    Science.gov (United States)

    Brown, R.L.; Wiggins, M.L.; Gupta, A.

    2002-01-01

    Detecting the saturation of a fractured reservoir using shear waves is possible when the fractures have a geometry that induces a component of movement perpendicular to the fractures. When such geometry is present, vertically traveling shear waves can be used to examine the saturation of the fractured reservoir. Tilted, corrugated, and saw-tooth fracture models are potential examples.

  6. Semiconductor saturable absorbers for ultrafast terahertz signals

    DEFF Research Database (Denmark)

    Hoffmann, Matthias C.; Turchinovich, Dmitry

    2010-01-01

    We demonstrate saturable absorber behavior of n-type semiconductors GaAs, GaP, and Ge in the terahertz THz frequency range at room temperature using nonlinear THz spectroscopy. The saturation mechanism is based on a decrease in electron conductivity of semiconductors at high electron momentum sta...

  7. Pedestrian Counting with Occlusion Handling Using Stereo Thermal Cameras

    Directory of Open Access Journals (Sweden)

    Miklas S. Kristoffersen

    2016-01-01

    Full Text Available The number of pedestrians walking the streets or gathered in public spaces is a valuable piece of information for shop owners, city governments, event organizers and many others. However, automatic counting that takes place day and night is challenging due to changing lighting conditions and the complexity of scenes with many people occluding one another. To address these challenges, this paper introduces the use of a stereo thermal camera setup for pedestrian counting. We investigate the reconstruction of 3D points in a pedestrian street with two thermal cameras and propose an algorithm for pedestrian counting based on clustering and tracking of the 3D point clouds. The method is tested on two five-minute video sequences captured at a public event with a moderate density of pedestrians and heavy occlusions. The counting performance is compared to the manually annotated ground truth and shows success rates of 95.4% and 99.1% for the two sequences.

  8. High performance universal analog and counting photodetector for LIDAR applications

    Science.gov (United States)

    Linga, Krishna; Krutov, Joseph; Godik, Edward; Seemungal, Wayne; Shushakov, Dmitry; Shubin, V. E.

    2005-08-01

    We demonstrate the feasibility of applying the emerging technology of internal discrete amplification to create an efficient, ultra low noise, universal analog and counting photodetector for LIDAR remote sensing. Photodetectors with internal discrete amplification can operate in the linear detection mode with a gain-bandwidth product of up to 1015 and in the photon counting mode with count rates of up to 109 counts/sec. Detectors based on this mechanism could have performance parameters superior to those of conventional avalanche photodiodes and photomultiplier tubes. For silicon photodetector prototypes, measured excess noise factor is as low as 1.02 at gains greater than 100,000. This gives the photodetectors and, consequently, the LIDAR systems new capabilities that could lead to important advances in LIDAR remote sensing.

  9. Determination of saturation functions and wettability for chalk based on measured fluid saturations

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, D.; Bech, N.; Moeller Nielsen, C.

    1998-08-01

    The end effect of displacement experiments on low permeable porous media is used for determination of relative permeability functions and capillary pressure functions. Saturation functions for a drainage process are determined from a primary drainage experiment. A reversal of the flooding direction creates an intrinsic imbibition process in the sample, which enables determination if imbibition saturation functions. The saturation functions are determined by a parameter estimation technique. Scanning effects are modelled by the method of Killough. Saturation profiles are determined by NMR. (au)

  10. Saturation process of nonlinear standing waves

    Institute of Scientific and Technical Information of China (English)

    马大猷; 刘克

    1996-01-01

    The sound pressure of the nonlinear standing waves is distorted as expected, but also tends to saturate as being found in standing-wave tube experiments with increasing sinusoidal excitation. Saturation conditions were not actually reached, owing to limited excitation power, but the evidence of tendency to saturation is without question. It is the purpose of this investigation to find the law of saturation from the existing experimental data. The results of curve fitting indicate that negative feedback limits the growth of sound pressure with increasing excitation, the growth of the fundamental and the second harmonic by the negative feedback of their sound pressures, and the growth of the third and higher harmonics, however, by their energies (sound pressures squared). The growth functions of all the harmonics are derived, which are confirmed by the experiments. The saturation pressures and their properties are found.

  11. Saturated pattern-illuminated Fourier ptychography microscopy

    Science.gov (United States)

    Fang, Yue; Chen, Youhua; Kuang, Cuifang; Xiu, Peng; Liu, Qiulan; Ge, Baoliang; Liu, Xu

    2017-01-01

    We report a series of simulation studies which extends pattern-illuminated Fourier ptychography microscopy by integrating with the nonlinearity arising from saturation of the fluorophore excited state for super-resolution fluorescence imaging. This extended technique, termed Saturated pattern-illuminated Fourier ptychography (SpiFP) microscopy, could achieve a resolution four times that of wide field when the illuminating light intensity approaches the saturation threshold in simulations. Increasing light intensity leads to further resolution enhancement. In order to demonstrate the performance of SpiFP, we make a comparison between SpiFP and saturated structure illumination microscopy in simulations, and prove that the SpiFP exhibits superior robustness to noise, aberration correcting ability, and pattern’s flexibility. Introducing the saturation of the fluorescent emission brings in notable improvements in imaging performance, implying its potential in nanoscale-sized biological observations by wide-field microscopy.

  12. The Mayan Long Count Calendar

    CERN Document Server

    Chanier, Thomas

    2013-01-01

    The Maya had a very elaborate and accurate calendar. First, the Mayan Long Count Calendar (LCC) was used to point historical events from a selected "beginning of time". It is also characterized by the existence of a religious month Tzolk'in of 260 days and a civic year Haab' of 365 days. The LCC is supposed to begin on 11 August -3114 BC known as the Goodman-Martinez-Thompson (GMT) correlation to the Gregorian calendar based on historical facts and end on 21 December 2012 corresponding to a period of approximately 5125 years or 13 Baktun. We propose here to explain the origin the 13 Baktun cycle, the Long Count Periods and the religious month Tzolk'in.

  13. Counting Irreducible Double Occurrence Words

    CERN Document Server

    Burns, Jonathan

    2011-01-01

    A double occurrence word $w$ over a finite alphabet $\\Sigma$ is a word in which each alphabet letter appears exactly twice. Such words arise naturally in the study of topology, graph theory, and combinatorics. Recently, double occurrence words have been used for studying DNA recombination events. We develop formulas for counting and enumerating several elementary classes of double occurrence words such as palindromic, irreducible, and strongly-irreducible words.

  14. Approximate Counting of Graphical Realizations.

    Science.gov (United States)

    Erdős, Péter L; Kiss, Sándor Z; Miklós, István; Soukup, Lajos

    2015-01-01

    In 1999 Kannan, Tetali and Vempala proposed a MCMC method to uniformly sample all possible realizations of a given graphical degree sequence and conjectured its rapidly mixing nature. Recently their conjecture was proved affirmative for regular graphs (by Cooper, Dyer and Greenhill, 2007), for regular directed graphs (by Greenhill, 2011) and for half-regular bipartite graphs (by Miklós, Erdős and Soukup, 2013). Several heuristics on counting the number of possible realizations exist (via sampling processes), and while they work well in practice, so far no approximation guarantees exist for such an approach. This paper is the first to develop a method for counting realizations with provable approximation guarantee. In fact, we solve a slightly more general problem; besides the graphical degree sequence a small set of forbidden edges is also given. We show that for the general problem (which contains the Greenhill problem and the Miklós, Erdős and Soukup problem as special cases) the derived MCMC process is rapidly mixing. Further, we show that this new problem is self-reducible therefore it provides a fully polynomial randomized approximation scheme (a.k.a. FPRAS) for counting of all realizations.

  15. Approximate Counting of Graphical Realizations.

    Directory of Open Access Journals (Sweden)

    Péter L Erdős

    Full Text Available In 1999 Kannan, Tetali and Vempala proposed a MCMC method to uniformly sample all possible realizations of a given graphical degree sequence and conjectured its rapidly mixing nature. Recently their conjecture was proved affirmative for regular graphs (by Cooper, Dyer and Greenhill, 2007, for regular directed graphs (by Greenhill, 2011 and for half-regular bipartite graphs (by Miklós, Erdős and Soukup, 2013. Several heuristics on counting the number of possible realizations exist (via sampling processes, and while they work well in practice, so far no approximation guarantees exist for such an approach. This paper is the first to develop a method for counting realizations with provable approximation guarantee. In fact, we solve a slightly more general problem; besides the graphical degree sequence a small set of forbidden edges is also given. We show that for the general problem (which contains the Greenhill problem and the Miklós, Erdős and Soukup problem as special cases the derived MCMC process is rapidly mixing. Further, we show that this new problem is self-reducible therefore it provides a fully polynomial randomized approximation scheme (a.k.a. FPRAS for counting of all realizations.

  16. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  17. Manual and automated reticulocyte counts.

    Science.gov (United States)

    Simionatto, Mackelly; de Paula, Josiane Padilha; Chaves, Michele Ana Flores; Bortoloso, Márcia; Cicchetti, Domenic; Leonart, Maria Suely Soares; do Nascimento, Aguinaldo José

    2010-12-01

    Manual reticulocyte counts were examined under light microscopy, using the property whereby supravital stain precipitates residual ribosomal RNA versus the automated flow methods, with the suggestion that in the latter there is greater precision and an ability to determine both mature and immature reticulocyte fractions. Three hundred and forty-one venous blood samples of patients were analyzed of whom 224 newborn and the rest adults; 51 males and 66 females, with ages between 0 and 89 years, as part of the laboratory routine for hematological examinations at the Clinical Laboratory of the Hospital Universitário do Oeste do Paraná. This work aimed to compare manual and automated methodologies for reticulocyte countings and evaluate random and systematic errors. The results obtained showed that the difference between the two methods was very small, with an estimated 0·4% systematic error and 3·9% random error. Thus, it has been confirmed that both methods, when well conducted, can reflect precisely the reticulocyte counts for adequate clinical use.

  18. A dengue model incorporating saturation incidence and human migration

    Science.gov (United States)

    Gakkhar, S.; Mishra, A.

    2015-03-01

    In this paper, a non-linear model has been proposed to investigate the effects of human migration on dengue dynamics. Human migration has been considered between two patches having different dengue strains. Due to migration secondary infection is possible. Further, the secondary infection is considered in patch-2 only as strain-2 in patch-2 is considered to be more severe than that of strain-1 in patch-1. The saturation incidence rate has been considered to incorporate the behavioral changes towards epidemic in human population. The basic reproduction number has been computed. Four Equilibrium states have been found and analyzed. Increasing saturation rate decreases the threshold thereby enhancing the stability of disease-free state in both the patches. Control on migration may lead to change in infection level of patches.

  19. Gluing Lidar Signals Detected in Analog-to-Digital and Photon Counting Modes

    Science.gov (United States)

    Feng, Chang-Zhong; Liu, Bing-Yi; Liu, Jin-Tao; Wu, Song-Hua

    2016-06-01

    Lidar is one of the most effective tools for atmospheric remote sensing. For a ground-based lidar system, the backscattered light usually has large dynamic range. Photon-counting mode has the capability to measure weak signal from high altitude, while Analog-to-Digital mode with better linearity is good at measuring strong signal at low altitude. In some lidar systems, atmospheric return signal is measured in both Analog-to-Digital and Photon Counting modes and combined into an entire profile by using a gluing algorithm. A method for gluing atmospheric return signal is developed and tested. For the Photon Counting signal, the saturation characteristics are analyzed to calculate the coefficients for correction. Then the Analog-to-Digital and Photon Counting signals are glued by a weighted average process. Results show the glued signal is reliable at both low and high altitudes.

  20. SATURATION BIOPSY OF THE PROSTATE (REVIEW

    Directory of Open Access Journals (Sweden)

    A. V. Sadchenko

    2014-07-01

    Full Text Available Prostate biopsy is the principal method of diagnois of prostate cancer, allowing to start the adequate treatment. The tactics of the patients, which have negative initial biopsy, is a subject of discussion. Saturation biopsy is a “gold standard„ of diagnostics of PCA with repeat biopsy. Saturation biopsy of the prostate is not a primary procedure, usually apply in patients with negative biopsies in anamnesis, patients with multifocal PIN and ASAP. Saturation biopsy allows to more precisely predict the volume and degree of malignancy of PCA, that can be used for planning tactics of active surveillance and focal therapy.

  1. Saturation Physics on the Energy Frontier

    CERN Document Server

    Zaslavsky, David

    2015-01-01

    Saturation physics is expected to be relevant at sufficiently small parton momentum fractions $x$ in high-energy proton- (or deuteron-)ion collisions at RHIC and the LHC. Accordingly, these collisions provide the best available testing ground for the saturation model. However, producing precise numerical predictions from the model is a complicated task; the state of the art in this area involves next-to-leading order QCD calculations, which are difficult to do numerically. Here I'll review recent progress in extracting numerical predictions from saturation models and matching them to experimental results.

  2. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  3. Avalanche photodiode photon counting receivers for space-borne lidars

    Science.gov (United States)

    Sun, Xiaoli; Davidson, Frederic M.

    1991-01-01

    Avalanche photodiodes (APD) are studied for uses as photon counting detectors in spaceborne lidars. Non-breakdown APD photon counters, in which the APD's are biased below the breakdown point, are shown to outperform: (1) conventional APD photon counters biased above the breakdown point; (2) conventional APD photon counters biased above the breakdown point; and (3) APD's in analog mode when the received optical signal is extremely weak. Non-breakdown APD photon counters were shown experimentally to achieve an effective photon counting quantum efficiency of 5.0 percent at lambda = 820 nm with a dead time of 15 ns and a dark count rate of 7000/s which agreed with the theoretically predicted values. The interarrival times of the counts followed an exponential distribution and the counting statistics appeared to follow a Poisson distribution with no after pulsing. It is predicted that the effective photon counting quantum efficiency can be improved to 18.7 percent at lambda = 820 nm and 1.46 percent at lambda = 1060 nm with a dead time of a few nanoseconds by using more advanced commercially available electronic components.

  4. Optical People Counting for Demand Controlled Ventilation: A Pilot Study of Counter Performance

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Sullivan, Douglas

    2009-12-26

    This pilot scale study evaluated the counting accuracy of two people counting systems that could be used in demand controlled ventilation systems to provide control signals for modulating outdoor air ventilation rates. The evaluations included controlled challenges of the people counting systems using pre-planned movements of occupants through doorways and evaluations of counting accuracies when naive occupants (i.e., occupants unaware of the counting systems) passed through the entrance doors of the building or room. The two people counting systems had high counting accuracy accuracies, with errors typically less than 10percent, for typical non-demanding counting events. However, counting errors were high in some highly challenging situations, such as multiple people passing simultaneously through a door. Counting errors, for at least one system, can be very high if people stand in the field of view of the sensor. Both counting system have limitations and would need to be used only at appropriate sites and where the demanding situations that led to counting errors were rare.

  5. High counting rate, two-dimensional position sensitive timing RPC

    CERN Document Server

    Petrovici, M.; Simion, V; Bartos, D; Caragheorgheopol, G; Deppner, I; Adamczewski-Musch, J; Linev, S; Williams, MCS; Loizeau, P; Herrmann, N; Doroud, K; Radulescu, L; Constantin, F

    2012-01-01

    Resistive Plate Chambers (RPCs) are widely employed as muon trigger systems at the Large Hadron Collider (LHC) experiments. Their large detector volume and the use of a relatively expensive gas mixture make a closed-loop gas circulation unavoidable. The return gas of RPCs operated in conditions similar to the experimental background foreseen at LHC contains large amount of impurities potentially dangerous for long-term operation. Several gas-cleaning agents, characterized during the past years, are currently in use. New test allowed understanding of the properties and performance of a large number of purifiers. On that basis, an optimal combination of different filters consisting of Molecular Sieve (MS) 5Å and 4Å, and a Cu catalyst R11 has been chosen and validated irradiating a set of RPCs at the CERN Gamma Irradiation Facility (GIF) for several years. A very important feature of this new configuration is the increase of the cycle duration for each purifier, which results in better system stabilit...

  6. Signatures of synchrony in pairwise count correlations

    Directory of Open Access Journals (Sweden)

    Tatjana Tchumatchenko

    2010-04-01

    Full Text Available Concerted neural activity can reflect specific features of sensory stimuli or behavioral tasks. Correlation coefficients and count correlations are frequently used to measure correlations between neurons, design synthetic spike trains and build population models. But are correlation coefficients always a reliable measure of input correlations? Here, we consider a stochastic model for the generation of correlated spike sequences which replicate neuronal pairwise correlations in many important aspects. We investigate under which conditions the correlation coefficients reflect the degree of input synchrony and when they can be used to build population models. We find that correlation coefficients can be a poor indicator of input synchrony for some cases of input correlations. In particular, count correlations computed for large time bins can vanish despite the presence of input correlations. These findings suggest that network models or potential coding schemes of neural population activity need to incorporate temporal properties of correlated inputs and take into consideration the regimes of firing rates and correlation strengths to ensure that their building blocks are an unambiguous measures of synchrony.

  7. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  8. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  9. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  10. Saturated fat, carbohydrate, and cardiovascular disease

    National Research Council Canada - National Science Library

    Siri-Tarino, Patty W; Sun, Qi; Hu, Frank B; Krauss, Ronald M

    2010-01-01

    A focus of dietary recommendations for cardiovascular disease (CVD) prevention and treatment has been a reduction in saturated fat intake, primarily as a means of lowering LDL-cholesterol concentrations...

  11. Saturated thickness, High Plains aquifer, 2009

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This raster data set represents the saturated thickness of the High Plains aquifer of the United States, 2009, in feet. The High Plains aquifer underlies...

  12. Combinatorics of saturated secondary structures of RNA.

    Science.gov (United States)

    Clote, P

    2006-11-01

    Following Zuker (1986), a saturated secondary structure for a given RNA sequence is a secondary structure such that no base pair can be added without violating the definition of secondary structure, e.g., without introducing a pseudoknot. In the Nussinov-Jacobson energy model (Nussinov and Jacobson, 1980), where the energy of a secondary structure is -1 times the number of base pairs, saturated secondary structures are local minima in the energy landscape, hence form kinetic traps during the folding process. Here we present recurrence relations and closed form asymptotic limits for combinatorial problems related to the number of saturated secondary structures. In addition, Python source code to compute the number of saturated secondary structures having k base pairs can be found at the web servers link of bioinformatics.bc.edu/clotelab/.

  13. Semiconductor saturable absorbers for ultrafast THz signals

    DEFF Research Database (Denmark)

    Hoffmann, Matthias C.; Turchinovich, Dmitry

    We demonstrate saturable absorber behavior of n-type semiconductors in the THz frequency range using nonlinear THz spectroscopy. Further, we observe THz pulse shortening and increase of the group refractive index at high field strengths....

  14. Ultrafast THz Saturable Absorption in Doped Semiconductors

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry; Hoffmann, Matthias C.

    2011-01-01

    We demonstrate ultrafast THz saturable absorption in n-doped semiconductors by nonlinear THz time-domain spectroscopy. This effect is caused by the semiconductor conductivity modulation due to electron heating and satellite-valley scattering in strong THz fields.......We demonstrate ultrafast THz saturable absorption in n-doped semiconductors by nonlinear THz time-domain spectroscopy. This effect is caused by the semiconductor conductivity modulation due to electron heating and satellite-valley scattering in strong THz fields....

  15. Correlation study between platelet count, leukocyte count, nonhemorrhagic complications, and duration of hospital stay in dengue fever with thrombocytopenia

    Science.gov (United States)

    Jayanthi, Hari Kishan; Tulasi, Sai Krishna

    2016-01-01

    Introduction: Dengue is one of the common diseases presenting as fever with thrombocytopenia, also causing significant morbidity and complications. Objectives: Though the correlation between platelet count, bleeding manifestations and hemorrhagic complications has been extensively studied, less is known about the correlation between platelet count and non hemorrhagic complications. This study was done to see the correlation between platelet count and non hemorrhagic complications, duration of hospital stay and additive effect of leucopenia with thrombocytopenia on complications. Methods: Our study is prospective observational study done on 99 patients who had dengue fever with thrombocytopenia. Correlations were obtained using scatter plot and SPSS software trail version. Results: Transaminitis (12.12%) was the most common complication followed by acute renal injury (2%). In our study we found that, as the platelet count decreased the complication rate increased (P = 0.0006). In our study duration of hospital increased (P is 0.00597) with decreasing platelet count when compared to other study where there was no correlation between the two. There was no correlation between thrombocytopenia with leucopenia and complications (P is 0.292), similar to other study. Conclusion: Platelet count can be used to predict the complication and duration of hospital stay and hence better use of resources. PMID:27453855

  16. The Relationship between Pollen Count Levels and Prevalence of Japanese Cedar Pollinosis in Northeast Japan

    Directory of Open Access Journals (Sweden)

    Kohei Honda

    2013-01-01

    Conclusions: These results suggest that pollen count levels may correlate with the rate of sensitization for JC pollinosis, but may not affect the rate of onset among sensitized children in northeast Japan.

  17. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  18. Monte Carlo Simulation of Counting Experiments.

    Science.gov (United States)

    Ogden, Philip M.

    A computer program to perform a Monte Carlo simulation of counting experiments was written. The program was based on a mathematical derivation which started with counts in a time interval. The time interval was subdivided to form a binomial distribution with no two counts in the same subinterval. Then the number of subintervals was extended to…

  19. Digital coincidence counting - initial results

    Science.gov (United States)

    Butcher, K. S. A.; Watt, G. C.; Alexiev, D.; van der Gaast, H.; Davies, J.; Mo, Li; Wyllie, H. A.; Keightley, J. D.; Smith, D.; Woods, M. J.

    2000-08-01

    Digital Coincidence Counting (DCC) is a new technique in radiation metrology, based on the older method of analogue coincidence counting. It has been developed by the Australian Nuclear Science and Technology Organisation (ANSTO), in collaboration with the National Physical Laboratory (NPL) of the United Kingdom, as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue-to-digital converter acquisition system for collecting pulse information from a 4π beta detector and an NaI(Tl) gamma detector. The digitised pulse information is stored on a high-speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software-based algorithms. In this letter we describe some recent results obtained with the new acquistion hardware being tested at ANSTO. The system is fully operational and is now in routine use. Results for 60Co and 22Na radiation activity calibrations are presented, initial results with 153Sm are also briefly mentioned.

  20. Association between absolute blood eosinophil count and CKD stages among cardiac patients.

    Science.gov (United States)

    Ishii, Rui; Fujita, Shu-Ichi; Kizawa, Shun; Sakane, Kazushi; Morita, Hideaki; Ozeki, Michishige; Sohmiya, Koichi; Hoshiga, Masaaki; Ishizaka, Nobukazu

    2016-02-01

    Elevated eosinophil count was shown to be associated with the development of cholesterol embolization syndrome, a potentially life-threatening condition, after catheter-based procedures. We investigated the association between stages of chronic kidney disease (CKD) and the absolute eosinophil count (AEC) among cardiac patients. CKD stages were determined solely on the estimated glomerular filtration rate or requirement for hemodialysis. Eosinophilia is defined as an eosinophil count exceeding 500/μL. A total of 1022 patients were enrolled in the current study, and eosinophil counts (/μL) in the first through fourth eosinophil count quartiles were blood pressure, and total white blood cell count. Similarly, after adjustment for the same variables, eosinophilia was associated with severe renal dysfunction with an odds ratio of 2.60 (95 % confidence interval, 1.08-6.26, P count was positively associated with higher CKD stages among cardiology patients, some fraction of which might be related to subclinical cholesterol embolization.

  1. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  2. Correcting for accidental correlations in saturated avalanche photodiodes

    CERN Document Server

    Grieve, James A; Tang, Zhongkan; Ling, Alexander

    2015-01-01

    In this paper we present a high-level numerical model for estimating rates of accidental correlations between a pair of passively quenched Geiger mode avalanche photodiodes operating in the saturated regime. By considering the recovery time of both the diodes and the detection circuit we introduce the concept of an "effective duty cycle" and show that it may be estimated by numeric simulation. The impact of effective duty cycle on the observed accidental rate is examined and we demonstrate that the updated model leads to an improved correction factor in actual experiments. This will improve the signal-to-noise ratio in applications depending on correlation measurements.

  3. SATURATED ZONE IN-SITU TESTING

    Energy Technology Data Exchange (ETDEWEB)

    P.W. REIMUS

    2004-11-08

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain, Nevada. The test interpretations provide estimates of flow and transport parameters used in the development of parameter distributions for total system performance assessment (TSPA) calculations. These parameter distributions are documented in ''Site-Scale Saturated Zone Flow Model (BSC 2004 [DIRS 170037]), Site-Scale Saturated Zone Transport'' (BSC 2004 [DIRS 170036]), Saturated Zone Colloid Transport (BSC 2004 [DIRS 170006]), and ''Saturated Zone Flow and Transport Model Abstraction'' (BSC 2004 [DIRS 170042]). Specifically, this scientific analysis contributes the following to the assessment of the capability of the SZ to serve as part of a natural barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvial Testing Complex (ATC) located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass

  4. On the Saturation of the Magnetorotational Instability via Parasitic Modes

    DEFF Research Database (Denmark)

    Pessah, Martin Elias; Goodman, Jeremy

    2009-01-01

    We investigate the stability of incompressible, exact, non-ideal magnetorotational (MRI) modes against parasitic instabilities. Both Kelvin-Helmholtz and tearing-mode parasitic instabilities may occur in the dissipative regimes accessible to current numerical simulations. We suppose that a primary...... MRI mode saturates at an amplitude such that its fastest parasite has a growth rate comparable to its own. The predicted alpha parameter then depends critically on whether the fastest primary and parasitic modes fit within the computational domain and whether non-axisymmetric parasitic modes...... are allowed. Hence even simulations that resolve viscous and resistive scales may not saturate properly unless the numerical domain is large enough to allow the free evolution of both MRI and parasitic modes. To minimally satisfy these requirements in simulations with vertical background fields, the vertical...

  5. LIQUEFACTION AND DISPLACEMENT OF SATURATED SAND UNDER VERTICAL VIBRATION LOADING

    Institute of Scientific and Technical Information of China (English)

    LU Xiaobing; TAN Qingming; CHENG C.M.; YU Shanbing; CUI Peng

    2004-01-01

    In order to investigate the influence of the vertical vibration loading on the liquefaction of saturated sand, one dimensional model for the saturated sand with a vertical vibration is presented based on the two phase continuous media theory. The development of the liquefaction and the liquefaction region are analyzed. It is shown that the vertical vibration loading could induce liquefaction.The rate of the liquefaction increases with the increase of the initial limit strain or initial porosity or amplitude and frequency of loading, and increases with the decrease of the permeability or initial modulus. It is shown also that there is a phase lag in the sand column. When the sand permeability distribution is non-uniform, the pore pressure and the strain will rise sharply where the permeability is the smallest, and fracture might be induced. With the development of liquefaction, the strength of the soil foundation becomes smaller and smaller. In the limiting case, landslides or debris flows could occur.

  6. Ultrafast pulse generation with black phosphorus solution saturable absorber

    Science.gov (United States)

    Li, Lu; Wang, Yonggang; Wang, Xi

    2017-08-01

    The study presents the mode-locked Er-doped fiber (EDF) laser with a black phosphorus (BP) solution saturable absorber (SSA). The saturable absorber (SA) is fabricated based on a D-shaped fiber (DF) embedded in BP nanosheets N-Methylpyrrolidone solution. Such a BP solution method has the virtues of good antioxidant capacity, high heat dissipation and high damage threshold. This kind of SA shows a modulation depth of 7.75% and a nonsaturable loss of 10%. By employing the EDF-BP SSA, a repetition rate of 15.2 MHz mode-locked fiber laser is achieved. The pulse duration is 580 fs and the signal-to-noise ratio is 65 dB. The results indicate that the DF-BP solution can work as a potential SA for ultrafast nonlinear optics.

  7. Neutron triples counting data for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Croft, Stephen, E-mail: crofts@ornl.gov [Oak Ridge National laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831 (United States); LaFleur, Adrienne M. [Los Alamos National Laboratory, Los Alamos , NM 87545 (United States); McElroy, Robert D. [Oak Ridge National laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37831 (United States); Swinhoe, Martyn T. [Los Alamos National Laboratory, Los Alamos , NM 87545 (United States)

    2015-06-01

    Correlated neutron counting using multiplicity shift register logic extracts the first three factorial moments from the detected neutron pulse train. The descriptive properties of the measurement item (mass, the ratio of (α,n) to spontaneous fission neutron production, and leakage self-multiplication) are related to the observed singles (S), doubles (D) and triples (T) rates, and this is the basis of the widely used multiplicity counting assay method. The factorial moments required to interpret and invert the measurement data in the framework of the point kinetics model may be calculated from the spontaneous fission prompt neutron multiplicity distribution P(ν). In the case of {sup 238}U very few measurements of P(ν) are available and the derived values, especially for the higher factorial moments, are not known with high accuracy. In this work, we report the measurement of the triples rate per gram of {sup 238}U based on the analysis of a set of measurements in which a collection of 10 cylinders of UO{sub 2}F{sub 2}, each containing about 230 g of compound, were measured individually and in groups. Special care was taken to understand and compensate the recorded multiplicity histograms for the effect of random cosmic-ray induced background neutrons, which, because they also come in bursts and mimic fissions but with a different and harder multiplicity distribution. We compare our fully corrected (deadtime, background, efficiency, multiplication) experimental results with first principles expectations based on evaluated nuclear data. Based on our results we suspect that the current evaluated nuclear data is biased, which points to a need to undertake new basic measurements of the {sup 238}U prompt neutron multiplicity distribution.

  8. Automatic cell counting with ImageJ.

    Science.gov (United States)

    Grishagin, Ivan V

    2015-03-15

    Cell counting is an important routine procedure. However, to date there is no comprehensive, easy to use, and inexpensive solution for routine cell counting, and this procedure usually needs to be performed manually. Here, we report a complete solution for automatic cell counting in which a conventional light microscope is equipped with a web camera to obtain images of a suspension of mammalian cells in a hemocytometer assembly. Based on the ImageJ toolbox, we devised two algorithms to automatically count these cells. This approach is approximately 10 times faster and yields more reliable and consistent results compared with manual counting.

  9. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    Energy Technology Data Exchange (ETDEWEB)

    Peronio, P.; Acconcia, G.; Rech, I.; Ghioni, M. [Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano (Italy)

    2015-11-15

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring “long” data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (∼80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

  10. Improving the counting efficiency in time-correlated single photon counting experiments by dead-time optimization

    Science.gov (United States)

    Peronio, P.; Acconcia, G.; Rech, I.; Ghioni, M.

    2015-11-01

    Time-Correlated Single Photon Counting (TCSPC) has been long recognized as the most sensitive method for fluorescence lifetime measurements, but often requiring "long" data acquisition times. This drawback is related to the limited counting capability of the TCSPC technique, due to pile-up and counting loss effects. In recent years, multi-module TCSPC systems have been introduced to overcome this issue. Splitting the light into several detectors connected to independent TCSPC modules proportionally increases the counting capability. Of course, multi-module operation also increases the system cost and can cause space and power supply problems. In this paper, we propose an alternative approach based on a new detector and processing electronics designed to reduce the overall system dead time, thus enabling efficient photon collection at high excitation rate. We present a fast active quenching circuit for single-photon avalanche diodes which features a minimum dead time of 12.4 ns. We also introduce a new Time-to-Amplitude Converter (TAC) able to attain extra-short dead time thanks to the combination of a scalable array of monolithically integrated TACs and a sequential router. The fast TAC (F-TAC) makes it possible to operate the system towards the upper limit of detector count rate capability (˜80 Mcps) with reduced pile-up losses, addressing one of the historic criticisms of TCSPC. Preliminary measurements on the F-TAC are presented and discussed.

  11. Modifications of Oxygen Saturation During Transesophageal Echocardiography.

    Science.gov (United States)

    Macor, Franco; Zottarel, Gabriella; Antonini-Canterin, Francesco; Mimo, Renata; Pavan, Daniela; Cervesato, Eugenio; Nicolosi, Gianluigi; Zanuttini, Domenico

    1997-05-01

    The present study was designed: (1) to establish the effects of transesophageal echocardiography (TEE) on arterial oxygen saturation (SAO(2)%); (2) to verify the possible clinical consequences of this phenomenon; and (3) to study the possibility of predicting modifications of SAO(2)% by clinical or hemodynamic variables or by specific factors related to the TEE procedure. We prospectively studied 116 unselected patients, aged 61 +/- 12 years, who underwent diagnostic TEE for various clinical indications. Thirty-seven patients had mitral valve disease, 19 aortic valve disease, 14 combined mitroaortic disease, 8 congenital heart disease, and 38 other cardiovascular diseases. Eight patients were affected by chronic obstructive pulmonary disease. Ninety-seven patients were sedated by 4 +/- 2 mg of diazepam IV SAO(2)% (5-min average) (Ohmeda Biox 3700 pulse oxymeter finger probe), heart rate (HR), and blood pressure (BP) were considered during baseline transthoracic examination, after pharmacological sedation but before the introduction of the probe, and finally during TEE. Neither clinical complications nor major arrhythmias were observed. Baseline SAO(2)%, HR and BP were, respectively, 93.6 +/- 3.3%, 76 +/- 14 beats/min, and 129 +/- 20/75 +/- 10 mmHg. Pharmacological sedation did not modify SAO(2)%, HR, and BP (P > 0.1). During TEE a small but significant reduction in SAO(2)% by an average of 1.2 +/- 3.2% was observed (P 0.1 for both systolic and diastolic). The changes of SAO(2)% and HR were not interrelated and were not related to the duration of the procedure and to any of the clinical and hemodynamic variables taken into consideration. TEE can induce a small but significant drop in SAO(2)% and a small increase in HR even without any clinical relevance. No clinical or hemodynamic variable or specific factors related to the TEE procedure were related to these changes.

  12. Calibration of dual-energy gamma systems for determining liquid saturations during multiphase flow in soil

    Energy Technology Data Exchange (ETDEWEB)

    Bali, K.M.; Grismer, M.E. [University of California, Cooperative Extension and University of California, Holtville (United States)

    1994-12-31

    The purpose of this study was to calibrate a dual-energy gamma system for simultaneous determination of aqueous and non-aqueous phase liquid (NAPL) in soil column. A dual energy gamma system containing {sup 241}Am and {sup 137}Cs was used to study the infiltration and displacement of aqueous liquid by NAPL and vice versa. Distilled water and Nal solution, and Soltrol 130 were used as fluids. The system was calibrated to minimize errors in liquid saturations due to random nature of gamma photons emission and drift in the photon detection equipment. The measurement accuracy in liquid saturations was substantially improved by increasing counting time and fluid attenuation coefficient. Nal salt was used to increase the attenuation coefficient of water. Measured and predicted liquid saturation during immiscible displacement in soil were consistent with mass balance measurements and anticipated deviations in saturations from probable error calculations. The calibration procedure resulted in a significant improvement in the prediction of liquid saturation using dual-energy gamma system. (author). 8 refs, 4 tabs.

  13. Simulated effects of nitrogen saturation on the global carbon budget using the IBIS model

    Science.gov (United States)

    Lu, Xuehe; Jiang, Hong; Liu, Jinxun; Zhang, Xiuying; Jin, Jiaxin; Zhu, Qiuan; Zhang, Zhen; Peng, Changhui

    2016-12-01

    Over the past 100 years, human activity has greatly changed the rate of atmospheric N (nitrogen) deposition in terrestrial ecosystems, resulting in N saturation in some regions of the world. The contribution of N saturation to the global carbon budget remains uncertain due to the complicated nature of C-N (carbon-nitrogen) interactions and diverse geography. Although N deposition is included in most terrestrial ecosystem models, the effect of N saturation is frequently overlooked. In this study, the IBIS (Integrated BIosphere Simulator) was used to simulate the global-scale effects of N saturation during the period 1961–2009. The results of this model indicate that N saturation reduced global NPP (Net Primary Productivity) and NEP (Net Ecosystem Productivity) by 0.26 and 0.03 Pg C yr‑1, respectively. The negative effects of N saturation on carbon sequestration occurred primarily in temperate forests and grasslands. In response to elevated CO2 levels, global N turnover slowed due to increased biomass growth, resulting in a decline in soil mineral N. These changes in N cycling reduced the impact of N saturation on the global carbon budget. However, elevated N deposition in certain regions may further alter N saturation and C-N coupling.

  14. Simulated effects of nitrogen saturation the global carbon budget using the IBIS model

    Science.gov (United States)

    Lu, Xuehe; Jiang, Hong; Liu, Jinxun; Zhang, Xiuying; Jin, Jiaxin; Zhu, Qiuan; Zhang, Zhen; Peng, Changhui

    2016-01-01

    Over the past 100 years, human activity has greatly changed the rate of atmospheric N (nitrogen) deposition in terrestrial ecosystems, resulting in N saturation in some regions of the world. The contribution of N saturation to the global carbon budget remains uncertain due to the complicated nature of C-N (carbon-nitrogen) interactions and diverse geography. Although N deposition is included in most terrestrial ecosystem models, the effect of N saturation is frequently overlooked. In this study, the IBIS (Integrated BIosphere Simulator) was used to simulate the global-scale effects of N saturation during the period 1961–2009. The results of this model indicate that N saturation reduced global NPP (Net Primary Productivity) and NEP (Net Ecosystem Productivity) by 0.26 and 0.03 Pg C yr−1, respectively. The negative effects of N saturation on carbon sequestration occurred primarily in temperate forests and grasslands. In response to elevated CO2 levels, global N turnover slowed due to increased biomass growth, resulting in a decline in soil mineral N. These changes in N cycling reduced the impact of N saturation on the global carbon budget. However, elevated N deposition in certain regions may further alter N saturation and C-N coupling.

  15. Assessing Rotation-Invariant Feature Classification for Automated Wildebeest Population Counts.

    Directory of Open Access Journals (Sweden)

    Colin J Torney

    Full Text Available Accurate and on-demand animal population counts are the holy grail for wildlife conservation organizations throughout the world because they enable fast and responsive adaptive management policies. While the collection of image data from camera traps, satellites, and manned or unmanned aircraft has advanced significantly, the detection and identification of animals within images remains a major bottleneck since counting is primarily conducted by dedicated enumerators or citizen scientists. Recent developments in the field of computer vision suggest a potential resolution to this issue through the use of rotation-invariant object descriptors combined with machine learning algorithms. Here we implement an algorithm to detect and count wildebeest from aerial images collected in the Serengeti National Park in 2009 as part of the biennial wildebeest count. We find that the per image error rates are greater than, but comparable to, two separate human counts. For the total count, the algorithm is more accurate than both manual counts, suggesting that human counters have a tendency to systematically over or under count images. While the accuracy of the algorithm is not yet at an acceptable level for fully automatic counts, our results show this method is a promising avenue for further research and we highlight specific areas where future research should focus in order to develop fast and accurate enumeration of aerial count data. If combined with a bespoke image collection protocol, this approach may yield a fully automated wildebeest count in the near future.

  16. High quantum efficiency S-20 photocathodes in photon counting detectors

    Science.gov (United States)

    Orlov, D. A.; DeFazio, J.; Duarte Pinto, S.; Glazenborg, R.; Kernen, E.

    2016-04-01

    Based on conventional S-20 processes, a new series of high quantum efficiency (QE) photocathodes has been developed that can be specifically tuned for use in the ultraviolet, blue or green regions of the spectrum. The QE values exceed 30% at maximum response, and the dark count rate is found to be as low as 30 Hz/cm2 at room temperature. This combination of properties along with a fast temporal response makes these photocathodes ideal for application in photon counting detectors, which is demonstrated with an MCP photomultiplier tube for single and multi-photoelectron detection.

  17. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  18. Photon counting compressive depth mapping

    CERN Document Server

    Howland, Gregory A; Ware, Matthew R; Howell, John C

    2013-01-01

    We demonstrate a compressed sensing, photon counting lidar system based on the single-pixel camera. Our technique recovers both depth and intensity maps from a single under-sampled set of incoherent, linear projections of a scene of interest at ultra-low light levels around 0.5 picowatts. Only two-dimensional reconstructions are required to image a three-dimensional scene. We demonstrate intensity imaging and depth mapping at 256 x 256 pixel transverse resolution with acquisition times as short as 3 seconds. We also show novelty filtering, reconstructing only the difference between two instances of a scene. Finally, we acquire 32 x 32 pixel real-time video for three-dimensional object tracking at 14 frames-per-second.

  19. Generalized Entropy Concentration for Counts

    CERN Document Server

    Oikonomou, Kostas N

    2016-01-01

    We consider the phenomenon of entropy concentration under linear constraints in a discrete setting, using the "balls and bins" paradigm, but without the assumption that the number of balls allocated to the bins is known. Therefore instead of \\ frequency vectors and ordinary entropy, we have count vectors with unknown sum, and a certain generalized entropy. We show that if the constraints bound the allowable sums, this suffices for concentration to occur even in this setting. The concentration can be either in terms of deviation from the maximum generalized entropy value, or in terms of the norm of the difference from the maximum generalized entropy vector. Without any asymptotic considerations, we quantify the concentration in terms of various parameters, notably a tolerance on the constraints which ensures that they are always satisfied by an integral vector. Generalized entropy maximization is not only compatible with ordinary MaxEnt, but can also be considered an extension of it, as it allows us to address...

  20. An alternative calibration method for counting P-32 reactor monitors

    Energy Technology Data Exchange (ETDEWEB)

    Quirk, T.J. [Applied Nuclear Technologies, Sandia National Laboratories, MS 1143, PO Box 5800, Albuquerque, NM 87185-1143 (United States); Vehar, D.W. [Sandia National Laboratories, Albuquerque, NM 87185-1143 (United States)

    2011-07-01

    Radioactivation of sulfur is a common technique used to measure fast neutron fluences in test and research reactors. Elemental sulfur can be pressed into pellets and used as monitors. The {sup 32}S(n, p) {sup 32}P reaction has a practical threshold of about 3 MeV and its cross section and associated uncertainties are well characterized [1]. The product {sup 32P} emits a beta particle with a maximum energy of 1710 keV [2]. This energetic beta particle allows pellets to be counted intact. ASTM Standard Test Method for Measuring Reaction Rates and Fast-Neutron Fluences by Radioactivation of Sulfur-32 (E265) [3] details a method of calibration for counting systems and subsequent analysis of results. This method requires irradiation of sulfur monitors in a fast-neutron field whose spectrum and intensity are well known. The resultant decay-corrected count rate is then correlated to the known fast neutron fluence. The Radiation Metrology Laboratory (RML) at Sandia has traditionally performed calibration irradiations of sulfur pellets using the {sup 252}Cf spontaneous fission neutron source at the National Inst. of Standards and Technology (NIST) [4] as a transfer standard. However, decay has reduced the intensity of NIST's source; thus lowering the practical upper limits of available fluence. As of May 2010, neutron emission rates have decayed to approximately 3 e8 n/s. In practice, this degradation of capabilities precludes calibrations at the highest fluence levels produced at test reactors and limits the useful range of count rates that can be measured. Furthermore, the reduced availability of replacement {sup 252}Cf threatens the long-term viability of the NIST {sup 252}Cf facility for sulfur pellet calibrations. In lieu of correlating count rate to neutron fluence in a reference field the total quantity of {sup 32}P produced in a pellet can be determined by absolute counting methods. This offers an attractive alternative to extended {sup 252}Cf exposures because

  1. Numerical modelling of multicomponent LNAPL dissolution kinetics at residual saturation in a saturated subsurface system

    Indian Academy of Sciences (India)

    M Vasudevan; G Suresh Kumar; Indumathi M Nambi

    2014-12-01

    Characterization of aquifers contaminated by petroleum hydrocarbons is limited by the use of dissolution mass transfer correlations developed for single compounds without considering the effects of the mass transfer limitations in presence of other components. A one-dimensional implicit numerical model is developed for the coupled mass transfer and transport processes and the results are analysed using existing mass transfer correlations for better understanding of the single and multicomponent dissolution processes. Themass transfer coefficient in the multicomponent system is found to be more nonlinear and extending with changing slope, unlike the exponential reduction for single compound system. During the initial phase, the dissolution rate of a soluble compound is very high due to the high concentration gradient, and as dissolution progresses, its effective solubility decreases with change in mole fraction. At higher pore volumes, the mole fractions of lower solubility fractions increase which can result in higher effective solubility. The kinetics of interphase mass transfer by dissolution and sorption is favoured by coupled biodegradation. However, mass transfer limitation for more soluble compounds under the conditions of low residual saturation and low mole fraction is observed to be due to low dissolution rate coefficient rather than decreasing concentration gradient.

  2. Saturable inductor and transformer structures for magnetic pulse compression

    Science.gov (United States)

    Birx, Daniel L.; Reginato, Louis L.

    1990-01-01

    Saturable inductor and transformer for magnetic compression of an electronic pulse, using a continuous electrical conductor looped several times around a tightly packed core of saturable inductor material.

  3. Controls by saturation state on etch pit formation during calcite dissolution

    Science.gov (United States)

    Teng, H. Henry

    2004-01-01

    Dissolution experiments were conducted on {101¯4} cleavage faces of calcite at various under-saturations to determine how the saturation state controls etch pit formation. Experimental observations were made by using in situ fluid cell Atomic Force Microscopy. Three dissolution modes were observed. When the saturation index Ω > 0.541, no etch pit formation was seen and dissolution primarily occurred at existing steps. When Ω decreased to Ω c = 0.541-0.410, the first visible pits appeared and continuous reduction in saturation state slowly increased the pit density on terraces while dissolution simultaneously proceeded at step edges. Finally, when the saturation state fell below Ω max = ˜0.007, a precipitous increase in pit density took place that sharply contrasted to the ordered fashion of pit formation observed at saturation conditions above this level. These observations are interpreted to be two-dimensional and unassisted pit formation at Ω 0.541. The values of Ω c are in good agreement with the dislocation theory's predicted critical under-saturations for pit formation at line dislocations. The occurrence of Ω max is not directly predicted but is a logical consequence of dissolution thermodynamics. These findings suggest that (1) dissolution near and far from equilibrium (i.e., Ω > Ω c, Ω unassisted pit nucleation at Ω ˜ Ω max is not predicted by the current dissolution rate equations. This suggests that an accurate 'general' rate law describing universal dissolution processes has yet to be developed.

  4. Comparative evaluation of oxygen saturation during periodontal surgery with or without oral conscious sedation in anxious patients

    OpenAIRE

    2014-01-01

    Context: Stress and anxiety during dental procedure can alter respiratory rate and thereby alter oxygen saturation in the blood, leading to emergencies like syncope. It can be prevented by preoperative intravenous sedation. However, it can lead to respiratory depression. Hence, this study was carried out to analyze the effect of oral conscious sedation on oxygen saturation during periodontal surgery in anxious patients. Aim: The aim was to compare the oxygen saturation levels during periodont...

  5. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  6. Design and construction of a photon counting system

    Science.gov (United States)

    Pérez, F. R.; Del Valle, C.; Reyes, L.; Tobón, J.; Barrero, C.; Velásquez, A.

    2007-03-01

    This article describes the design and implementation of a photon counting system, which is made using low cost electronic devices. The system is connected to a spectrometer in order to study events related to low levels of luminance intensity. It uses a photo-multiplier tube (PMT) for photon detection. The counting photon system is conformed by 5 stages, which are: the detector, a pre-amplifier, a pulse comparator, a pulses counter and a communications interface in a PC. Data acquisition is done through the serial port. The system allows the detection of radiation coming from signals whose counting rates are several thousands pulses per second. As an application of the system, the Raman Stokes spectrum of the polystyrene as well as the fluorescence band of an organic pigment on a poly-vinyl matrix is showed.

  7. Void fraction prediction in saturated flow boiling

    Energy Technology Data Exchange (ETDEWEB)

    Francisco J Collado [Dpto de Ingenieria Mecanica-Motores Termicos, CPS-B, Universidad de Zaragoza, Maria de Luna 50018-Zaragoza (Spain)

    2005-07-01

    Full text of publication follows: An essential element in thermal-hydraulics is the accurate prediction of the vapor void fraction, or fraction of the flow cross-sectional area occupied by steam. Recently, the author has suggested to calculate void fraction working exclusively with thermodynamic properties. It is well known that the usual 'flow' quality, merely a mass flow rate ratio, is not at all a thermodynamic property because its expression in function of thermodynamic properties includes the slip ratio, which is a parameter of the process not a function of state. By the other hand, in the classic and well known expression of the void fraction - in function of the true mass fraction of vapor (also called 'static' quality), and the vapor and liquid densities - does not appear the slip ratio. Of course, this would suggest a direct procedure for calculating the void fraction, provided we had an accurate value of the true mass fraction of vapor, clearly from the heat balance. However the classic heat balance is usually stated in function of the 'flow' quality, what sounds really contradictory because this parameter, as we have noted above, is not at all a thermodynamic property. Then we should check against real data the actual relationship between the thermodynamic properties and the applied heat. For saturated flow boiling just from the inlet of the heated tube, and not having into account the kinetic and potential terms, the uniform applied heat per unit mass of inlet water and per unit length (in short, specific linear heat) should be closely related to a (constant) slope of the mixture enthalpy. In this work, we have checked the relation between the specific linear heat and the thermodynamic enthalpy of the liquid-vapor mixture using the actual mass fraction. This true mass fraction is calculated using the accurate measurements of the outlet void fraction taken during the Cambridge project by Knights and Thom in the sixties for

  8. Elimination of spin diffusion effects in saturation transfer experiments: application to hydrogen exchange in proteins.

    Science.gov (United States)

    Jensen, Malene Ringkjøbing; Kristensen, Søren M; Led, Jens J

    2007-03-01

    The NMR saturation transfer experiment is widely used to characterize exchange processes in proteins that take place on the ms-s timescale. However, spin diffusion effects are inherently associated with the saturation transfer experiment and may overshadow the effect of the exchange processes of interest. As shown here, the effects from spin diffusion and exchange processes can be separated by varying the field strength of the saturation pulse, thereby allowing correct exchange rates to be obtained. The method is demonstrated using the hydrogen exchange process in the protein Escherichia coli thioredoxin as an example.

  9. Soil Structure and Saturated Hydraulic Conductivity

    Science.gov (United States)

    Houskova, B.; Nagy, V.

    The role of soil structure on saturated hydraulic conductivity changes is studied in plough layers of texturally different soils. Three localities in western part of Slovakia in Zitny ostrov (Corn Island) were under investigation: locality Kalinkovo with light Calcaric Fluvisol (FAO 1970), Macov with medium heavy Calcari-mollic Fluvisol and Jurova with heavy Calcari-mollic Fluvisol. Soil structure was determined in dry as well as wet state and in size of macro and micro aggregates. Saturated hydraulic conductivity was measured by the help of double ring method. During the period of ring filling the soil surface was protected against aggregates damage by falling water drops. Spatial and temporal variability of studied parameters was evaluated. Cultivated crops were ensilage maize at medium heavy and heavy soil and colza at light soil. Textural composition of soil and actual water content at the beginning of measurement are one of major factor affecting aggregate stability and consequently also saturated hydraulic conductivity.

  10. The Danish tax on saturated fat

    DEFF Research Database (Denmark)

    Vallgårda, Signild; Holm, Lotte; Jensen, Jørgen Dejgård

    2015-01-01

    BACKGROUND/OBJECTIVES: Health promoters have repeatedly proposed using economic policy tools, taxes and subsidies, as a means of changing consumer behaviour. As the first country in the world, Denmark introduced a tax on saturated fat in 2011. It was repealed in 2012. In this paper, we present...... on saturated fat had been suggested by two expert committees and was introduced with a majority in parliament, as a part of a larger economic reform package. Many actors, including representatives from the food industry and nutrition researchers, opposed the tax both before and after its introduction, claiming......, research was published showing that consumption of saturated fat had declined in Denmark. CONCLUSIONS: The analysis indicates that the Danish tax on fat was introduced mainly to increase public revenue. As the tax had no strong proponents and many influential adversaries, it was repealed. New research...

  11. Dilatant hardening of fluid-saturated sandstone

    Science.gov (United States)

    Makhnenko, Roman Y.; Labuz, Joseph F.

    2015-02-01

    The presence of pore fluid in rock affects both the elastic and inelastic deformation processes, yet laboratory testing is typically performed on dry material even though in situ the rock is often saturated. Techniques were developed for testing fluid-saturated porous rock under the limiting conditions of drained, undrained, and unjacketed response. Confined compression experiments, both conventional triaxial and plane strain, were performed on water-saturated Berea sandstone to investigate poroelastic and inelastic behavior. Measured drained response was used to calibrate an elasto-plastic constitutive model that predicts undrained inelastic deformation. The experimental data show good agreement with the model: dilatant hardening in undrained triaxial and plane strain compression tests under constant mean stress was predicted and observed.

  12. Multiplicity counting from fission chamber signals in the current mode

    Science.gov (United States)

    Pázsit, I.; Pál, L.; Nagy, L.

    2016-12-01

    In nuclear safeguards, estimation of sample parameters using neutron-based non-destructive assay methods is traditionally based on multiplicity counting with thermal neutron detectors in the pulse mode. These methods in general require multi-channel analysers and various dead time correction methods. This paper proposes and elaborates on an alternative method, which is based on fast neutron measurements with fission chambers in the current mode. A theory of "multiplicity counting" with fission chambers is developed by incorporating Böhnel's concept of superfission [1] into a master equation formalism, developed recently by the present authors for the statistical theory of fission chamber signals [2,3]. Explicit expressions are derived for the first three central auto- and cross moments (cumulants) of the signals of up to three detectors. These constitute the generalisation of the traditional Campbell relationships for the case when the incoming events represent a compound Poisson distribution. Because now the expressions contain the factorial moments of the compound source, they contain the same information as the singles, doubles and triples rates of traditional multiplicity counting. The results show that in addition to the detector efficiency, the detector pulse shape also enters the formulas; hence, the method requires a more involved calibration than the traditional method of multiplicity counting. However, the method has some advantages by not needing dead time corrections, as well as having a simpler and more efficient data processing procedure, in particular for cross-correlations between different detectors, than the traditional multiplicity counting methods.

  13. Radium-228 analysis of natural waters by Cherenkov counting of Actinium-228

    Energy Technology Data Exchange (ETDEWEB)

    Aleissa, Khalid A.; Almasoud, Fahad I.; Islam, Mohammed S. [Atomic Energy Research Institute, King Abdul Aziz City for Science and Technology, P.O. Box 6086, Riyadh 11442 (Saudi Arabia); L' Annunziata, Michael F. [IAEA Expert, Montague Group, P.O. Box 5033, Oceanside, CA 92052-5033 (United States)], E-mail: mlannunziata@cox.net

    2008-12-15

    The activities of {sup 228}Ra in natural waters were determined by the Cherenkov counting of the daughter nuclide {sup 228}Ac. The radium was pre-concentrated on MnO{sub 2} and the radium purified via ion exchange and, after a 2-day period of incubation to allow for secular equilibrium between the parent-daughter {sup 228}Ra({sup 228}Ac), the daughter nuclide {sup 228}Ac was isolated by ion exchange according to the method of Nour et al. [2004. Radium-228 determination of natural waters via concentration on manganese dioxide and separation using Diphonix ion exchange resin. Appl. Radiat. Isot. 61, 1173-1178]. The Cherenkov photons produced by {sup 228}Ac were counted directly without the addition of any scintillation reagents. The optimum Cherenkov counting window, sample volume, and vial type were determined experimentally to achieve optimum Cherenkov photon detection efficiency and lowest background count rates. An optimum detection efficiency of 10.9{+-}0.1% was measured for {sup 228}Ac by Cherenkov counting with a very low Cherenkov photon background of 0.317{+-}0.013 cpm. The addition of sodium salicylate into the sample counting vial at a concentration of 0.1 g/mL yielded a more than 3-fold increase in the Cherenkov detection efficiency of {sup 228}Ac to 38%. Tests of the Cherenkov counting technique were conducted with several water standards of known activity and the results obtained compared closely with a conventional liquid scintillation counting technique. The advantages and disadvantages of Cherenkov counting compared to liquid scintillation counting methods are discussed. Advantages include much lower Cherenkov background count rates and consequently lower minimal detectable activities for {sup 228}Ra and no need for expensive environmentally unfriendly liquid scintillation cocktails. The disadvantages of the Cherenkov counting method include the need to measure {sup 228}Ac Cherenkov photon detection efficiency and optimum Cherenkov counting volume

  14. Radium-228 analysis of natural waters by Cherenkov counting of Actinium-228.

    Science.gov (United States)

    Aleissa, Khalid A; Almasoud, Fahad I; Islam, Mohammed S; L'Annunziata, Michael F

    2008-12-01

    The activities of (228)Ra in natural waters were determined by the Cherenkov counting of the daughter nuclide (228)Ac. The radium was pre-concentrated on MnO(2) and the radium purified via ion exchange and, after a 2-day period of incubation to allow for secular equilibrium between the parent-daughter (228)Ra((228)Ac), the daughter nuclide (228)Ac was isolated by ion exchange according to the method of Nour et al. [2004. Radium-228 determination of natural waters via concentration on manganese dioxide and separation using Diphonix ion exchange resin. Appl. Radiat. Isot. 61, 1173-1178]. The Cherenkov photons produced by (228)Ac were counted directly without the addition of any scintillation reagents. The optimum Cherenkov counting window, sample volume, and vial type were determined experimentally to achieve optimum Cherenkov photon detection efficiency and lowest background count rates. An optimum detection efficiency of 10.9+/-0.1% was measured for (228)Ac by Cherenkov counting with a very low Cherenkov photon background of 0.317+/-0.013cpm. The addition of sodium salicylate into the sample counting vial at a concentration of 0.1g/mL yielded a more than 3-fold increase in the Cherenkov detection efficiency of (228)Ac to 38%. Tests of the Cherenkov counting technique were conducted with several water standards of known activity and the results obtained compared closely with a conventional liquid scintillation counting technique. The advantages and disadvantages of Cherenkov counting compared to liquid scintillation counting methods are discussed. Advantages include much lower Cherenkov background count rates and consequently lower minimal detectable activities for (228)Ra and no need for expensive environmentally unfriendly liquid scintillation cocktails. The disadvantages of the Cherenkov counting method include the need to measure (228)Ac Cherenkov photon detection efficiency and optimum Cherenkov counting volume, which are not at all required when liquid

  15. Femoral venous oxygen saturation is no surrogate for central venous oxygen saturation

    NARCIS (Netherlands)

    van Beest, Paul A.; van der Schors, Alice; Liefers, Henriette; Coenen, Ludo G. J.; Braam, Richard L.; Habib, Najib; Braber, Annemarije; Scheeren, Thomas W. L.; Kuiper, Michael A.; Spronk, Peter E.

    2012-01-01

    Objective:  The purpose of our study was to determine if central venous oxygen saturation and femoral venous oxygen saturation can be used interchangeably during surgery and in critically ill patients. Design:  Prospective observational controlled study. Setting:  Nonacademic university-affiliated t

  16. Development of A Blood Oxygen Saturation and Heart Rate Signal Collector of Sleeping Environment Regulating System%睡眠环境调节系统的血氧饱和度与心率信号采集环节研制

    Institute of Scientific and Technical Information of China (English)

    黄俊杰; 孙骁; 刘燕; 黄耀樑

    2012-01-01

    Sleep is the rest stage for energy recovery and storage after daily activities The sleep quality in this stage is closely related to health Temperature, humidity, oxygen content, noise, illumination, anion, etc of the sleeping environment are connected with the sleep quality tightly In order to gain better sleep effect, it is necessary to provide sleeping environment which can be automatically adjusted according to physiological parameters This paper designs the blood oxygen saturation and heart rate signal collector using MSP430F2274 and CC2500 as core module based on the development tool eZ430-RF2500 from Texas Instruments, achieves to collect process and wirelessly transmit pulse signals, and provides measurement methods of physiological parameters for the sleeping environment regulating system%睡眠是人在一天活动后进行精力恢复和能量贮存的休复阶段.该阶段的睡眠质量好坏与身体健康密切相关,而睡眠环境的温度、湿度、氧含量、噪音、光照、负离子等与睡眠质量有着紧密的联系.为了让人可以获得最佳睡眠效果,有必要提供可根据人体生理参数进行自动调节的睡眠环境.基于TI公司的eZ430-RF2500开发工具,设计开发了以MSP430F2274芯片和CC2500芯片为核心模块的血氧与心率信号检测环节,实现对脉搏波信号的采集、处理与无线发送,为睡眠环境调节系统提供前级人体生理参数的测量手段.

  17. Saturable brain-to-blood transport of endomorphins.

    Science.gov (United States)

    Kastin, A J; Fasold, M B; Smith, R R; Horner, K A; Zadina, J E

    2001-07-01

    Opiate-modulating tetrapeptides such as tyrosine-melanocyte-stimulating hormone-release inhibiting factor-1 (Tyr-MIF-1; Tyr-Pro-Leu-Gly-NH2) and Tyr-W-MIF-1 (Tyr-Pro-Trp-Gly-NH2) are saturably transported from brain to blood. We examined whether two recently described endogenous opiate tetrapeptides with similar structures, the mu-specific endomorphins, also are transported across the blood-brain barrier (BBB). We found that the efflux rates of endomorphin-1 (Tyr-Pro-Trp-Phe-NH2) and endomorphin-2 (Tyr-Pro-Phe-Phe-NH2) were each self-inhibited by an excess of the respective endomorphin, thereby defining saturable transport. Cross-inhibition of the transport of each endomorphin by the other indicated shared transport. By contrast, no inhibition of the efflux of either endomorphin resulted from coadministration of Tyr-MIF-1, indicating that peptide transport system-1 (PTS-1) was not involved. Tyr-W-MIF-1, which is partially transported by PTS-1, significantly (Pendomorphin-1 and tended (P=0.051) to decrease the transport of endomorphin-2, consistent with its role as both an opiate and antiopiate. Although involved in modulation of pain, coinjection of calcitonin gene-related peptide or constriction of the sciatic nerve did not appear to inhibit endomorphin efflux. Thus, the results demonstrate the existence of a new efflux system across the BBB which saturably transports endomorphins from brain to blood.

  18. Site-Scale Saturated Zone Flow Model

    Energy Technology Data Exchange (ETDEWEB)

    G. Zyvoloski

    2003-12-17

    The purpose of this model report is to document the components of the site-scale saturated-zone flow model at Yucca Mountain, Nevada, in accordance with administrative procedure (AP)-SIII.lOQ, ''Models''. This report provides validation and confidence in the flow model that was developed for site recommendation (SR) and will be used to provide flow fields in support of the Total Systems Performance Assessment (TSPA) for the License Application. The output from this report provides the flow model used in the ''Site-Scale Saturated Zone Transport'', MDL-NBS-HS-000010 Rev 01 (BSC 2003 [162419]). The Site-Scale Saturated Zone Transport model then provides output to the SZ Transport Abstraction Model (BSC 2003 [164870]). In particular, the output from the SZ site-scale flow model is used to simulate the groundwater flow pathways and radionuclide transport to the accessible environment for use in the TSPA calculations. Since the development and calibration of the saturated-zone flow model, more data have been gathered for use in model validation and confidence building, including new water-level data from Nye County wells, single- and multiple-well hydraulic testing data, and new hydrochemistry data. In addition, a new hydrogeologic framework model (HFM), which incorporates Nye County wells lithology, also provides geologic data for corroboration and confidence in the flow model. The intended use of this work is to provide a flow model that generates flow fields to simulate radionuclide transport in saturated porous rock and alluvium under natural or forced gradient flow conditions. The flow model simulations are completed using the three-dimensional (3-D), finite-element, flow, heat, and transport computer code, FEHM Version (V) 2.20 (software tracking number (STN): 10086-2.20-00; LANL 2003 [161725]). Concurrently, process-level transport model and methodology for calculating radionuclide transport in the saturated zone at Yucca

  19. Formation mechanism of cracks in saturated sand

    Institute of Scientific and Technical Information of China (English)

    Xiaobing Lu; Zhemin Zheng; Yongren Wu

    2006-01-01

    The formation mechanism of "water film" (or crack) in saturated sand is analyzed theoretically and numerically.The theoretical analysis shows that there will be no stable "water film" in the saturated sand if the strength of the skeleton is zero and no positions are choked.It is shown by numerical simulation that stable water films initiate and grow if the choking state keeps unchanged once the fluid velocities decrease to zero in the liquefied sand column.The developments of "water film" based on the model presented in this paper are compared with experimental results.

  20. A steady-state saturation model to determine the subsurface travel time (STT in complex hillslopes

    Directory of Open Access Journals (Sweden)

    T. Sabzevari

    2010-06-01

    Full Text Available The travel time of subsurface flow in complex hillslopes (hillslopes with different plan shape and profile curvature is an important parameter in predicting the subsurface flow in catchments. This time depends on the hillslopes geometry (plan shape and profile curvature, soil properties and climate conditions. The saturation capacity of hillslopes affect the travel time of subsurface flow. The saturation capacity, and subsurface travel time of compound hillslopes depend on parameters such as soil depth, porosity, soil hydraulic conductivity, plan shape (convergent, parallel or divergent, hillslope length, profile curvature (concave, straight or convex and recharge rate to the groundwater table. An equation for calculating subsurface travel time for all complex hillslopes was presented. This equation is a function of the saturation zone length (SZL on the surface. Saturation zone length of the complex hillslopes was calculated numerically by using the hillslope-storage kinematic wave equation for subsurface flow, so an analytical equation was presented for calculating the saturation zone length of the straight hillslopes and all plan shapes geometries. Based on our results, the convergent hillslopes become saturated very soon and they showed longer SZL with shorter travel time compared to the parallel and divergent ones. The subsurface average flow rate in convergent hillslopes is much less than the divergent ones in the steady state conditions. Concerning to subsurface travel time, convex hillslopes have more travel time in comparison to straight and concave hillslopes. The convex hillslopes exhibit more average flow rate than concave hillslopes and their saturation capacity is very low. Finally, the effects of recharge rate variations, average bedrock slope and soil depth on saturation zone extension were investigated.

  1. Efeitos da fisioterapia respiratória convencional versus aumento do fluxo expiratório na saturação de O2, freqüência cardíaca e freqüência respiratória, em prematuros no período pós-extubação Effects of conventional chest physical therapy versus increased expiratory flow on oxygen saturation, heart rate and respiratory rate in premature infants following extubation

    Directory of Open Access Journals (Sweden)

    LCO Antunes

    2006-01-01

    Full Text Available INTRODUÇÃO: Recém-nascidos (RN prematuros apresentam elevada morbidade respiratória e necessidade de ventilação mecânica, assim, a fisioterapia respiratória é parte integrante da assistência neonatal. Objetivo: Comparar os efeitos da fisioterapia respiratória convencional (FRC versus aumento do fluxo expiratório (AFE, na saturação de O2 (SpO2, freqüência cardíaca (FC e na freqüência respiratória (FR em prematuros no período pós-extubação. Método: Ensaio clínico randomizado realizado na UTI Neonatal do Hospital das Clínicas de BotucatuUNESP, comparando duas técnicas fisioterapêuticas, aplicadas em recém-nascidos prematuros, nas primeiras 48 horas pós-extubação. Para a análise estatística foram utilizados o teste t Student, Mann-Whitney, Qui-quadrado e o teste exato de Fisher, com nível de significância em 5%. Resultados: Os dois grupos de estudo: Grupo FRC (n= 20 e grupo AFE (n= 20, não diferiram quanto à idade gestacional (média de 28 semanas e peso de nascimento (média de 1100 gramas. Em ambos os grupos a síndrome do desconforto respiratório (SDR foi o principal diagnóstico. A mediana da idade no início da fisioterapia foi de sete dias no grupo AFE e 11 dias na FRC. Ambas as técnicas produziram aumento significativo da SpO2 aos 10 e 30 minutos, sem alterações na FR. A FC aumentou significativamente após a FRC e não se alterou após o AFE. Conclusão: Os resultados sugerem que o AFE é menos estressante que a FRC e pode ser aplicado em prematuros no período pós-extubação. Nestes recém-nascidos o AFE parece ser seguro e benéfico a curto prazo.Background: Respiratory morbidity and the need for mechanical ventilation are very high among preterm infants. Chest physical therapy is therefore an essential component of neonatal care. Objective: To compare the effects of conventional chest physical therapy (CCP and increased expiratory flow (IEF on the oxygen saturation (SpO2, heart rate, and

  2. Complete Blood Count and Retinal Vessel Calibers

    OpenAIRE

    Gerald Liew; Jie Jin Wang; Elena Rochtchina; Tien Yin Wong; Paul Mitchell

    2014-01-01

    OBJECTIVE: The influence of hematological indices such as complete blood count on microcirculation is poorly understood. Retinal microvasculature can be directly visualized and vessel calibers are associated with a range of ocular and systemic diseases. We examined the association of complete blood count with retinal vessel calibers. METHODS: Cross-sectional population-based Blue Mountains Eye Study, n = 3009, aged 49+ years. Complete blood count was measured from fasting blood samples taken ...

  3. Improvement of Delayed Neutron Counting System

    Institute of Scientific and Technical Information of China (English)

    YUAN; Guo-jun; XIAO; Cai-jin; YANG; Wei; ZHANG; Gui-ying; JIN; Xiang-chun; WANG; Ping-sheng; NI; Bang-fa

    2012-01-01

    <正>A new delayed neutron counting system, which is good at qualitative and quantitative analysis of fissionable nuclide mixture, will be established at China Advanced Research Reactor (CARR). We use 3 He proportional counters to count the delayed neutrons after the samples irradiated by reactor neutrons, including U3O8-stantard, uranium ore and enriched uranium. Then, the counting efficiency and limit of this system were calculated.

  4. Effects of lek count protocols on greater sage-grouse population trend estimates

    Science.gov (United States)

    Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.

    2016-01-01

    Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count

  5. Vector perturbations of galaxy number counts

    Science.gov (United States)

    Durrer, Ruth; Tansella, Vittorio

    2016-07-01

    We derive the contribution to relativistic galaxy number count fluctuations from vector and tensor perturbations within linear perturbation theory. Our result is consistent with the the relativistic corrections to number counts due to scalar perturbation, where the Bardeen potentials are replaced with line-of-sight projection of vector and tensor quantities. Since vector and tensor perturbations do not lead to density fluctuations the standard density term in the number counts is absent. We apply our results to vector perturbations which are induced from scalar perturbations at second order and give numerical estimates of their contributions to the power spectrum of relativistic galaxy number counts.

  6. Vector perturbations of galaxy number counts

    CERN Document Server

    Durrer, Ruth

    2016-01-01

    We derive the contribution to relativistic galaxy number count fluctuations from vector and tensor perturbations within linear perturbation theory. Our result is consistent with the the relativistic corrections to number counts due to scalar perturbation, where the Bardeen potentials are replaced with line-of-sight projection of vector and tensor quantities. Since vector and tensor perturbations do not lead to density fluctuations the standard density term in the number counts is absent. We apply our results to vector perturbations which are induced from scalar perturbations at second order and give numerical estimates of their contributions to the power spectrum of relativistic galaxy number counts.

  7. Saturated fat, carbohydrates and cardiovascular disease

    NARCIS (Netherlands)

    Kuipers, R. S.; de Graaf, D. J.; Luxwolda, M. F.; Muskiet, M. H. A.; Dijck-Brouwer, D. A. J.; Muskiet, F. A. J.

    The dietary intake of saturated fatty acids (SAFA) is associated with a modest increase in serum total cholesterol, but not with cardiovascular disease (CVD). Replacing dietary SAFA with carbohydrates (CHO), notably those with a high glycaemic index, is associated with an increase in CVD risk in

  8. Two-beam interaction in saturable media

    DEFF Research Database (Denmark)

    Schjødt-Eriksen, Jens; Schmidt, Michel R.; Juul Rasmussen, Jens

    1998-01-01

    The dynamics of two coupled soliton solutions of the nonlinear Schrodinger equation with a saturable nonlinearity is investigated It is shown by means of a variational method and by direct numerical calculations that two well-separated solitons can orbit around each other, if their initial velocity...

  9. Modeling of Current Transformers Under Saturation Conditions

    Directory of Open Access Journals (Sweden)

    Martin Prochazka

    2006-01-01

    Full Text Available During a short circuit the input signal of the relay can be distort by the magnetic core saturation of the current transformer. It is useful to verify the behavior of CT by a mathematical model. The paper describes one phase and three phase models and it presents some methods of how to analyze and classify a deformed secondary current

  10. Radiation Chemistry of Organic Liquids: Saturated Hydrocarbons

    CERN Document Server

    Shkrob, Ilya A; Trifunac, A D

    2004-01-01

    In this review (124 refs), several problems in radiolysis of saturated hydrocarbons are examined. Special attention is paid to the chemistry of radical cations, high-mobility holes, excited state and spur dynamics, magnetic field and spin effects, and optically detected magnetic resonance spectroscopy.

  11. The myth of plant species saturation

    Science.gov (United States)

    Thomas J. Stohlgren; David T. Barnett; Catherine S. Jarnevich; Curtis Flather; John Kartesz

    2008-01-01

    Plant species assemblages, communities or regional floras might be termed saturated when additional immigrant species are unsuccessful at establishing due to competitive exclusion or other inter-specific interactions, or when the immigration of species is off-set by extirpation of species. This is clearly not the case for state, regional or national floras in the USA...

  12. Nasal pulse oximetry overestimates oxygen saturation

    DEFF Research Database (Denmark)

    Rosenberg, J; Pedersen, M H

    1990-01-01

    Ten surgical patients were monitored with nasal and finger pulse oximetry (Nellcor N-200) for five study periods with alternating mouth and nasal breathing and switching of cables and sensors. Nasal pulse oximetry was found to overestimate arterial oxygen saturation by 4.7 (SD 1.4%) (bias...

  13. Saturation at low x and nonlinear evolution

    OpenAIRE

    Stasto, A. M.

    2002-01-01

    In this talk the results of the analytical and numerical analysis of the nonlinear Balitsky-Kovchegov equation are presented. The characteristic BFKL diffusion into infrared regime is suppressed by the generation of the saturation scale. We identify the scaling and linear regimes for the solution. We also study the impact of subleading corrections onto the nonlinear evolution.

  14. Fabrication of PDMS/SWCNT thin films as saturable absorbers

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez-Romano, I; Sanchez-Mondragon, J J [Photonics and Optical Physics Laboratory, Optics Department, INAOE Apdo. Postal 51 and 216, Tonantzintla, Puebla 72000 (Mexico); Davila-Rodriguez, J; Delfyett, P J [CREOL, The College of Optics and Photonics, University of Central Florida, Orlando, FL 32816-2700 (United States); May-Arrioja, D A, E-mail: hromano@inaoep.mx [Depto. de Ingenieria Electronica, UAM Reynosa Rodhe, Universidad Autonoma de Tamaulipas, Carr. Reynosa-San Fernando S/N, Reynosa, Tamaulipas 88779 (Mexico)

    2011-01-01

    We present a novel technique to fabricate a saturable absorber thin film based on Polydimethylsiloxane doped with Single Wall Carbon Nanotubes. Using this film a passive mode-locked fiber laser in a standard ring cavity configuration was built by inserting the film between two angled connectors. Self-starting passively mode-locked laser operation was easily observed. The generated pulses have a width of 1.26 ps at a repetition rate of 22.7 MHz with an average power of 4.89 mW.

  15. Transport and biodegradation of benzene in the saturated groundwater layer

    Directory of Open Access Journals (Sweden)

    Khongnakorn, W.

    2004-11-01

    Full Text Available The objective of this study was to investigate the biotic and abiotic processes that affected benzene transportation in the saturated groundwater layer. The study was performed in the laboratory using synthetic groundwater and soil sample from Maptaput Industrial Estate, Rayong. This study was divided into 3 parts; batch test, column test and computer modeling. The biotic, biodegradation, and the abiotic processes were studied in the batch system. The column experiment was performed to investigate the transport behavior of benzene. The computer program, CXTFIT, with parameters acquired from batch and column experiments was used to simulate the benzene transport behavior. It was found that benzene adsorption followed the linear adsorption isotherm with its coefficient (Kd of 0.544 cm3/g and the retardation factor of 5.43. The biodegradation rate could be estimated using the firstorder biodegradation rate equation with the degradation rate of 0.0009- 0.0092 per day. The dispersion coefficient estimated from column experiments was 0.0102 cm2/s. The results from computer simulation did not fit the experimental data well. It can be concluded that the transport of benzene was a non-equilibrium transport. It was also found that biodegradation of benzene had significant effect on benzene transportation in saturated groundwater. The simulated transport with biodegradation process fitted the data fairly.

  16. Soil aquifer treatment of artificial wastewater under saturated conditions

    KAUST Repository

    Essandoh, H. M K

    2011-05-01

    A 2000 mm long saturated laboratory soil column was used to simulate soil aquifer treatment under saturated conditions to assess the removal of chemical and biochemical oxygen demand (COD and BOD), dissolved organic carbon (DOC), nitrogen and phosphate, using high strength artificial wastewater. The removal rates were determined under a combination of constant hydraulic loading rates (HLR) and variable COD concentrations as well as variable HLR under a constant COD. Within the range of COD concentrations considered (42 mg L-1-135 mg L-1) it was found that at fixed hydraulic loading rate, a decrease in the influent concentrations of dissolved organic carbon (DOC), biochemical oxygen demand (BOD), total nitrogen and phosphate improved their removal efficiencies. At the high COD concentrations applied residence times influenced the redox conditions in the soil column. Long residence times were detrimental to the removal process for COD, BOD and DOC as anoxic processes and sulphate reduction played an important role as electron acceptors. It was found that total COD mass loading within the range of 911 mg d-1-1780 mg d-1 applied as low COD wastewater infiltrated coupled with short residence times would provide better effluent quality than the same mass applied as a COD with higher concentration at long residence times. The opposite was true for organic nitrogen where relatively high concentrations coupled with long residence time gave better removal efficiency. © 2011.

  17. 确定气态饱和胺分子振子强度与荧光辐射速率常数的关系探讨%Determination of the Relationship between the Oscillator Strengths and Fluorescence Radiative Rate Constants of the Gaseous Saturated Amines

    Institute of Scientific and Technical Information of China (English)

    邢波

    2012-01-01

    在此研究中,采用一系列具有相似结构的气态饱和单胺和二胺作为研究对象,应用Gaussian03计算化学软件,在DFT/B3LYP水平上,使用6-311+G(d)基组优化处于基态的胺分子结构并使用CIS/6-311+G(d)优化处于激发态胺分子的结构,计算激发能量、激发波长,以及S1←S0振子强度f。通过查得文献中已有的气态饱和胺的荧光寿命以及得到的荧光辐射速率常数实验数据,比较计算得出的振子强度f,得出结论:双胺的荧光寿命明显长于单胺;若f=0,表明跃迁禁阻,像DMPZ,DABCO,它们的荧光寿命很长,超过了770ns;若f〉0,则允许跃迁,饱和胺分子荧光寿命小于60ns。可由计算得出的f值,初步判断荧光物质在UV辐射作用下的荧光寿命长短。并得到振子强度f与荧光辐射速率常数线性关系。与基态分子结构比较,激发态的饱和胺分子结构发生改变。%In this research,a series of saturated monoamines and diamines with similar molecule structures are investigated.The Gaussian03 DFT/B3LYP/6-311+G(d) method was carried out to optimize the molecular structures in ground state.CIS/6-311+G(d) was used to optimize the S1 molecular structures and calculate the S1←S0 oscillator strengths(f values).The excitation energies,excitation wavelengths and S1←S0 oscillator strengths were calculated.The calculated oscillator strengths with the experimental lifetimes and radiative rate constants were compared.It concluded that the fluorescence lifetimes of diamines are much longer than that of monoamines.If f=0,for example,DMPZ and DABCO,the transition is forbidden and their fluorescence lifetimes exceed 770ns.If f0,the transition is allowed and the fluorescence lifetimes of these amines are less than 60ns.Using f values can estimate the fluorescence lifetimes under UV radiation.The oscillator strengths(f values) are linear with the fluorescence radiative rate constants.The geometries of

  18. Experimental investigation on the energy evolution of dry and water-saturated red sandstones

    Institute of Scientific and Technical Information of China (English)

    Zhang Zhizhen; Gao Feng

    2015-01-01

    In order to investigate the effect of water content on the energy evolution of red sandstone, the axial loading–unloading experiments on dry and water-saturated sandstone samples were conducted, and the distribution and evolution of elastic energy and dissipated energy within the rock were measured. The results show that the saturation process from dry to fully-saturated states reduces the strength, rigid-ity and brittleness of the rock by 30.2%, 25.5%and 16.7%, respectively. The water-saturated sample has larger irreversible deformation in the pre-peak stage and smaller stress drop in the post-peak stage. The saturation process decreases the accumulation energy limit by 38.9%, but increases the dissipated energy and residual elastic energy density, thus greatly reducing the magnitude and rate of energy release. The water-saturated sample has lower conversion efficiency to elastic energy by 3%in the pre-peak region; moreover, the elastic energy ratio falls with a smaller range in the post-peak stage. Therefore, saturation process can greatly reduce the risk of dynamic disaster, and heterogeneous water content can lead to dynamic disaster possibly on the other hand.

  19. Genetic Regulatory Networks that count to 3

    DEFF Research Database (Denmark)

    Lehmann, Martin; Sneppen, K.

    2013-01-01

    that contain repressive links, which we model by Michaelis-Menten terms. Interestingly, we find that counting to 3 does not require a hierarchy in Hill coefficients, in contrast to counting to 2, which is known from lambda phage. Furthermore, we find two main circuit architectures: one design also found...

  20. Correcting Finger Counting to Snellen Acuity.

    Science.gov (United States)

    Karanjia, Rustum; Hwang, Tiffany Jean; Chen, Alexander Francis; Pouw, Andrew; Tian, Jack J; Chu, Edward R; Wang, Michelle Y; Tran, Jeffrey Show; Sadun, Alfredo A

    2016-10-01

    In this paper, the authors describe an online tool with which to convert and thus quantify count finger measurements of visual acuity into Snellen equivalents. It is hoped that this tool allows for the re-interpretation of retrospectively collected data that provide visual acuity in terms of qualitative count finger measurements.

  1. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  2. It Is Time to Count Learning Communities

    Science.gov (United States)

    Henscheid, Jean M.

    2015-01-01

    As the modern learning community movement turns 30, it is time to determine just how many, and what type, of these programs exist at America's colleges and universities. This article first offers a rationale for counting learning communities followed by a description of how disparate counts and unclear definitions hamper efforts to embed these…

  3. Is It Counting, or Is It Adding?

    Science.gov (United States)

    Eisenhardt, Sara; Fisher, Molly H.; Thomas, Jonathan; Schack, Edna O.; Tassell, Janet; Yoder, Margaret

    2014-01-01

    The Common Core State Standards for Mathematics (CCSSI 2010) expect second grade students to "fluently add and subtract within 20 using mental strategies" (2.OA.B.2). Most children begin with number word sequences and counting approximations and then develop greater skill with counting. But do all teachers really understand how this…

  4. Replacing foods high in saturated fat by low-saturated fat alternatives: a computer simulation of the potential effects on reduction of saturated fat consumption

    NARCIS (Netherlands)

    Schickenberg, B.; Assema, P.; Brug, J.; Verkaik-Kloosterman, J.; Ocke, M.C.; Vries, de N.

    2009-01-01

    10 en%) increased from 23.3 % to 86.0 %. We conclude that the replacement of relatively few important high-saturated fat products by available lower-saturated fat alternatives can significantly reduce saturated fat intake and increase the proportion of individuals complying with recommended intake

  5. Monitoring Carbon Dioxide Saturation through Wireline Logging Techniques D. Vu-Hoang (SRPC), J Henninges (GfZ), S. Hurter (SCS)

    Science.gov (United States)

    Vu-Hoang, D.

    2009-04-01

    rays. Changes in the thermal neutron population in the media are sampled by gamma ray detectors placed at a short distance from the high energy pulsed neutron source. Σ, the macroscopic thermal neutron capture cross-section of the formation, is determined by analyzing the decline of gamma ray count rates with time as the neutrons are captured by surrounding materials (neutron capture) and as they diffuse farther away (neutron diffusion). Σ is inferred from this observed decline of gamma ray count rate versus time and is corrected for diffusion, borehole and lithology effects through the use of a database that includes over 1000 measured points augmented with 400 modeled points spanning different lithologies, porosities, borehole sizes, casing sizes and weights, formation salinities and borehole fluid salinities that are typically encountered in CCS operations. 3- Pulsed Neutron Interpretation: Since Σco2 has a value of 0.03 CU, knowing the formation water characteristics (Σw) and having a petrophysical formation evaluation (°, Vcl, Σcl, Σma), Sw the water saturation, can be derived from the following equation: Σlog = °gwΣw + ° (1- Sw) Σco2 + Vcl Σcl + (1 -g° - Vcl) Σma 4- Application to Ketzin: 4.1: Baseline logs: Immediately after the observation well was completed in 2007, a RST* baseline log was acquired in May 2007, with fresh water in the borehole. Due to the shallow RST* depth of investigation and the fresh borehole fluid invasion, it was decided to acquire another baseline in June 2008 with the borehole fluid the same as that of the original formation water (240 ppk). Fig. 2 shows the difference between the two baseline logs. With fresh water in the borehole, the 2007 baseline log exhibits a behavior similar to that of a formation filled with CO2 since fresh water has a low value of Σ. 4.2 Breakthrough: Breakthrough at the Ktz200 observation well, located 50 m from the injector occurred three weeks after the injection

  6. Synchrotron radiation measurement of multiphase fluid saturations in porous media: Experimental technique and error analysis

    Science.gov (United States)

    Tuck, David M.; Bierck, Barnes R.; Jaffé, Peter R.

    1998-06-01

    Multiphase flow in porous media is an important research topic. In situ, nondestructive experimental methods for studying multiphase flow are important for improving our understanding and the theory. Rapid changes in fluid saturation, characteristic of immiscible displacement, are difficult to measure accurately using gamma rays due to practical restrictions on source strength. Our objective is to describe a synchrotron radiation technique for rapid, nondestructive saturation measurements of multiple fluids in porous media, and to present a precision and accuracy analysis of the technique. Synchrotron radiation provides a high intensity, inherently collimated photon beam of tunable energy which can yield accurate measurements of fluid saturation in just one second. Measurements were obtained with precision of ±0.01 or better for tetrachloroethylene (PCE) in a 2.5 cm thick glass-bead porous medium using a counting time of 1 s. The normal distribution was shown to provide acceptable confidence limits for PCE saturation changes. Sources of error include heat load on the monochromator, periodic movement of the source beam, and errors in stepping-motor positioning system. Hypodermic needles pushed into the medium to inject PCE changed porosity in a region approximately ±1 mm of the injection point. Improved mass balance between the known and measured PCE injection volumes was obtained when appropriate corrections were applied to calibration values near the injection point.

  7. Saturated Zone In-Situ Testing

    Energy Technology Data Exchange (ETDEWEB)

    P. W. Reimus; M. J. Umari

    2003-12-23

    The purpose of this scientific analysis is to document the results and interpretations of field experiments that have been conducted to test and validate conceptual flow and radionuclide transport models in the saturated zone (SZ) near Yucca Mountain. The test interpretations provide estimates of flow and transport parameters that are used in the development of parameter distributions for Total System Performance Assessment (TSPA) calculations. These parameter distributions are documented in the revisions to the SZ flow model report (BSC 2003 [ 162649]), the SZ transport model report (BSC 2003 [ 162419]), the SZ colloid transport report (BSC 2003 [162729]), and the SZ transport model abstraction report (BSC 2003 [1648701]). Specifically, this scientific analysis report provides the following information that contributes to the assessment of the capability of the SZ to serve as a barrier for waste isolation for the Yucca Mountain repository system: (1) The bases for selection of conceptual flow and transport models in the saturated volcanics and the saturated alluvium located near Yucca Mountain. (2) Results and interpretations of hydraulic and tracer tests conducted in saturated fractured volcanics at the C-wells complex near Yucca Mountain. The test interpretations include estimates of hydraulic conductivities, anisotropy in hydraulic conductivity, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, matrix diffusion coefficients, fracture apertures, and colloid transport parameters. (3) Results and interpretations of hydraulic and tracer tests conducted in saturated alluvium at the Alluvium Testing Complex (ATC), which is located at the southwestern corner of the Nevada Test Site (NTS). The test interpretations include estimates of hydraulic conductivities, storativities, total porosities, effective porosities, longitudinal dispersivities, matrix diffusion mass transfer coefficients, and

  8. Reliability of the total lymphocyte count as a parameter of nutrition.

    Science.gov (United States)

    Forse, R A; Rompre, C; Crosilla, P; O-Tuitt, D; Rhode, B; Shizgal, H M

    1985-05-01

    To evaluate the total lymphocyte count as a means of nutritional assessment, body composition studies (a proven method of nutritional assessment) and total lymphocyte determinations were performed simultaneously in 153 patients. The total lymphocyte count correlated poorly with both the body cell mass and the nutritional state measured by the Nae to Ke ratio. For diagnosing malnutrition, the total lymphocyte count had a false-positive rate of 34% and a false-negative rate of 50%. In a group of 78 patients who received total parenteral nutrition for 2 weeks, the total lymphocyte count did not accurately reflect the nutritional changes. Due to its poor sensitivity and specificity, the total lymphocyte count is of no value as a measure of the nutritional state.

  9. Material Screening with HPGe Counting Station for PandaX Experiment

    CERN Document Server

    Wang, Xuming; Fu, Changbo; Ji, Xiangdong; Liu, Xiang; Mao, Yajun; Wang, Hongwei; Wang, Siguang; Xie, Pengwei; Zhang, Tao

    2016-01-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  10. Material screening with HPGe counting station for PandaX experiment

    Science.gov (United States)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Mao, Y.; Wang, H.; Wang, S.; Xie, P.; Zhang, T.

    2016-12-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  11. Response and comparison of erythrocyte sedimentary rate,leucocyte count and C-reactive protein in diabetic foot patients%血沉、白细胞计数和C反应蛋白在糖尿病足评估中的作用

    Institute of Scientific and Technical Information of China (English)

    何宇梅

    2015-01-01

    目的:本文旨在评估炎性因子而对不同程度的糖尿病足病患者作出早期判断的策略。方法对68例不同程度的糖尿病足病患者入院分别进行血沉、白细胞计数和C反应蛋白的测定并作比较。结果 C反应蛋白在2级~4级的糖尿病足病患者中是最有价值的标记物,而血沉、白细胞计数无法预示其程度。结论在不同程度的糖尿病足病患者中C反应蛋白是一个有价值的预测因子。%Objectives This study aimed to assess the diagnostic accuracy of inflammatory factor markers as all aid to making this distinction.It is therefore of paramount importance to assess strategies for different degree of diabetic foot at an early stage.Methods There were 68 diabetic foot patients who received to test erythrocyte sedimentary rate (ESR),leucocyte counts and C-reactive protein (CRP)during admitted our hospital.Then all parameters were performed mr comparison.Results As a single lnarker,CRP was the most informative for diabetic foot from grade 2 to grade 4 comparing with non-diabetic foot(P<0.05)in conr-tast.ESR and leucyte counlts were not predictive Conclusions Measnrelilent of all ilmamnlator marker CRP could be a valuable predictie , factor for different degree in diabetic foot patients .

  12. High energy resolution and high count rate gamma spectrometry measurement of primary coolant of generation 4 sodium-cooled fast reactor; Spectrometrie gamma haute resolution et hauts taux de comptage sur primaire de reacteur de type generation 4 au sodium liquide

    Energy Technology Data Exchange (ETDEWEB)

    Coulon, R.

    2010-11-10

    Sodium-cooled Fast Reactors are under development for the fourth generation of nuclear reactor. Breeders reactors could gives solutions for the need of energy and the preservation of uranium resources. An other purpose is the radioactive wastes production reduction by transmutation and the control of non-proliferation using a closed-cycle. These thesis shows safety and profit advantages that could be obtained by a new generation of gamma spectrometry system for SFR. Now, the high count rate abilities, allow us to study new methods of accurate power measurement and fast clad failure detection. Simulations have been done and an experimental test has been performed at the French Phenix SFR of the CEA Marcoule showing promising results for these new measurements. (author) [French] Les reacteurs a neutrons rapides refroidis au sodium sont en developpement en vue d'assurer une quatrieme generation de reacteurs repondant a la demande energetique, tout en assurant la preservation des ressources d'uranium par un fonctionnement en surgenerateur. L'objectif de la filiere est egalement d'ameliorer la gestion de la radiotoxicite des dechets produits par transmutation des actinides mineurs et de controler la non-proliferation par un fonctionnement en cycle ferme. Une instrumentation de surveillance et de controle de ce type de reacteur a ete etudiee dans cette these. La spectrometrie gamma de nouvelle generation permet, par les hauts taux de traitement aujourd'hui accessibles, d'envisager de nouvelles approches pour suivre avec une precision accrue la puissance neutronique et de detecter plus precocement des ruptures de gaine combustible. Des simulations numeriques ont ete realisees et une campagne d'essai a ete menee a bien sur le reacteur Phenix de Marcoule. Des perspectives prometteuses ont ete mises en exergue pour ces deux problematiques

  13. Influence of water saturation on propagation of elastic waves in transversely isotropic nearly saturated soil

    Institute of Scientific and Technical Information of China (English)

    李保忠; 蔡袁强

    2003-01-01

    Biot's two-phase theory for fluid-saturated porous media was applied in a study carried out to investigate the influence of water saturation on propagation of elastic wave in transversely isotropic nearly saturated soil. The characteristic equations for wave propagation were derived and solved analytically. The results showed that there are four waves: the first and second quasi-longitudinal waves (QP1 and QP2), the quasi-transverse wave (QSV) and the anti-plane transverse wave (SH). Numerical results are given to illustrate the influence of saturation on the velocity, dispersion and attenuation of the four body waves. Some typical numerical results are discussed and plotted. The results can be meaningful for soil dynamics and earthquake engineering.

  14. Controls on Highly Siderophile Element Concentrations in Martian Basalt: Sulfide Saturation and Under-Saturation

    Science.gov (United States)

    Righter, Kevin

    2009-01-01

    Highly siderophile elements (HSE; Re, Au and the platinum group elements) in shergottites exhibit a wide range from very high, similar to the terrestrial mantle, to very low, similar to sulfide saturated mid ocean ridge basalt (e.g., [1]). This large range has been difficult to explain without good constraints on sulfide saturation or under-saturation [2]. A new model for prediction of sulfide saturation places new constraints on this problem [3]. Shergottite data: For primitive shergottites, pressure and temperature estimates are between 1.2-1.5 GPa, and 1350-1470 C [4]. The range of oxygen fugacities is from FMQ-2 to IW, where the amount of Fe2O3 is low and thus does not have a significant effect on the S saturation values. Finally, the bulk compositions of shergottites have been reported in many recent studies (e.g., [5]). All of this information will be used to test whether shergottites are sulfide saturated [3]. Modeling values and results: The database for HSE partition coefficients has been growing with many new data for silicates and oxides [6-8] to complement a large sulfide database [9- 11]. Combining these data with simple batch melting models allows HSE contents of mantle melts to be estimated for sulfide-bearing vs. sulfide-free mantle. Combining such models with fractional crystallization modeling (e.g., [12]) allows HSE contents of more evolved liquids to be modeled. Most primitive shergottites have high HSE contents (and low S contents) that can be explained by sulfide under-saturated melting of the mantle. An exception is Dhofar 019 which has high S contents and very low HSE contents suggesting sulfide saturation. Most evolved basaltic shergottites have lower S contents than saturation, and intermediate HSE contents that can be explained by olivine, pyroxene, and chromite fractionation. An exception is EET A79001 lithology B, which has very low HSE contents and S contents higher than sulfide saturation values . evidence for sulfide saturation

  15. Space Charge Saturated Sheath Regime and Electron Temperature Saturation in Hall Thrusters

    Energy Technology Data Exchange (ETDEWEB)

    Y. Raitses; D. Staack; A. Smirnov; N.J. Fisch

    2005-03-16

    Secondary electron emission in Hall thrusters is predicted to lead to space charge saturated wall sheaths resulting in enhanced power losses in the thruster channel. Analysis of experimentally obtained electron-wall collision frequency suggests that the electron temperature saturation, which occurs at high discharge voltages, appears to be caused by a decrease of the Joule heating rather than by the enhancement of the electron energy loss at the walls due to a strong secondary electron emission.

  16. Comparison of pulseoximetry oxygen saturation and arterial oxygen saturation in open heart intensive care unit

    Directory of Open Access Journals (Sweden)

    Alireza Mahoori

    2013-08-01

    Full Text Available Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2 during clinical routine in such patients, and to examine the effect of mild acidosis on this relationship.Methods: In an observational prospective study 80 patients were evaluated in intensive care unit after cardiac surgery. SPO2 was recorded and compared with SaO2 obtained by blood gas analysis. One or serial arterial blood gas analyses (ABGs were performed via a radial artery line while a reliable pulseoximeter signal was present. One hundred thirty seven samples were collected and for each blood gas analyses, SaO2 and SPO2 we recorded.Results: O2 saturation as a marker of peripheral perfusion was measured by Pulseoxim-etry (SPO2. The mean difference between arterial oxygen saturation and pulseoximetry oxygen saturation was 0.12%±1.6%. A total of 137 paired readings demonstrated good correlation (r=0.754; P<0.0001 between changes in SPO2 and those in SaO2 in samples with normal hemoglobin. Also in forty seven samples with mild acidosis, paired readings demonstrated good correlation (r=0.799; P<0.0001 and the mean difference between SaO2 and SPO2 was 0.05%±1.5%.Conclusion: Data showed that in patients with stable hemodynamic and good signal quality, changes in pulseoximetry oxygen saturation reliably predict equivalent changes in arterial oxygen saturation. Mild acidosis doesn’t alter the relation between SPO2 and SaO2 to any clinically important extent. In conclusion, the pulse oximeter is useful to monitor oxygen saturation in patients with stable hemodynamic.

  17. The Danish tax on saturated fat

    DEFF Research Database (Denmark)

    Jensen, Jørgen Dejgård; Smed, Sinne

    2013-01-01

    Denmark introduced a new tax on saturated fat in food products with effect from October 2011. The objective of this paper is to make an effect assessment of this tax for some of the product categories most significantly affected by the new tax, namely fats such as butter, butter-blends, margarine...... and oils. This assessment is done by conducting an econometric analysis on weekly food purchase data from a large household panel dataset (GfK Consumer Tracking Scandinavia), spanning the period from January 2008 until July 2012.The econometric analysis suggest that the introduction of the tax on saturated...... and fats, a shift that seems to have been utilized by discount chains to raise the prices of butter and margarine by more than the pure tax increase. Due to the relatively short data period with the tax being active, interpretation of these findings from a long-run perspective should be done...

  18. Cause of winter gravity wave spectrum saturation

    Institute of Scientific and Technical Information of China (English)

    WU; Yongfu; XU; Jiyao

    2005-01-01

    This paper utilizes horizontal velocity measurements observed from 19 chaff rockets and nearly simultaneous temperature measurements collected from 19 falling sphere rockets to study the cause of winter gravity wave spectrum saturation. Results suggest that strong horizontal velocity shears larger than 0.04 s-1 are observed to be present at various heights near the winter mesopause. On one single chaff rocket flight, an extremely strong horizontal velocity shear as high as 0.33 s-1 is observed at 87.4 km and is believed to be the strongest value ever measured in the mesosphere. These strong horizontal velocity shears, together with Brunt-V(a)is(a)l(a) frequency squared obtained from the temperature profile, act collectively to yield two dynamical instability regions of Richardson number smaller than 1/4, suggesting that the saturated gravity wave spectrum observed by the chaff rockets in winter is a result of dynamical instability.

  19. The danish tax on saturated fat

    DEFF Research Database (Denmark)

    Jensen, Jørgen Dejgård; Smed, Sinne

    on saturated fat in food products has had some effects on the market for the considered products, in that the level of consumption of fats dropped by 10 – 20%. Furthermore, the analysis points at shifts in demand from high-price supermarkets towards low-price discount stores – a shift that seems to have been......Denmark introduced a new tax on saturated fat in food products with effect from October 2011. The objective of this paper is to make an effect assessment of this tax for some of the product categories most significantly affected by the new tax, namely fats such as butter, butter-blends, margarine...... and oils. This assessment was done by conducting an econometric analysis on weekly food purchase data from a large household panel dataset (GfK ConsumerTracking Scandinavia), spanning the period from January 2009 until December 2011.The econometric analysis suggest that the introduction of the tax...

  20. Flux saturation length of sediment transport.

    Science.gov (United States)

    Pähtz, Thomas; Kok, Jasper F; Parteli, Eric J R; Herrmann, Hans J

    2013-11-22

    Sediment transport along the surface drives geophysical phenomena as diverse as wind erosion and dune formation. The main length scale controlling the dynamics of sediment erosion and deposition is the saturation length Ls, which characterizes the flux response to a change in transport conditions. Here we derive, for the first time, an expression predicting Ls as a function of the average sediment velocity under different physical environments. Our expression accounts for both the characteristics of sediment entrainment and the saturation of particle and fluid velocities, and has only two physical parameters which can be estimated directly from independent experiments. We show that our expression is consistent with measurements of Ls in both aeolian and subaqueous transport regimes over at least 5 orders of magnitude in the ratio of fluid and particle density, including on Mars.