International Nuclear Information System (INIS)
Chen, Y.-S.; Chien, K.-H.; Wang, C.-C.; Hung, T.-C.; Pei, B.-S.
2006-01-01
The vapor chambers (flat plate heat pipes) have been applied on the electronic cooling recently. To satisfy the quick-response requirement of the industries, a simplified transient three-dimensional linear model has been developed and tested in this study. In the proposed model, the vapor is assumed as a single interface between the evaporator and condenser wicks, and this assumption enables the vapor chamber to be analyzed by being split into small control volumes. Comparing with the previous available results, the calculated transient responses have shown good agreements with the existing results. For further validation of the proposed model, a water-cooling experiment was conducted. In addition to the vapor chamber, the heating block is also taken into account in the simulation. It is found that the inclusion of the capacitance of heating block shows a better agreement with the measurements
Additively Manufactured Low Cost Upper Stage Combustion Chamber
Protz, Christopher; Cooper, Ken; Ellis, David; Fikes, John; Jones, Zachary; Kim, Tony; Medina, Cory; Taminger, Karen; Willingham, Derek
2016-01-01
Over the past two years NASA's Low Cost Upper Stage Propulsion (LCUSP) project has developed Additive Manufacturing (AM) technologies and design tools aimed at reducing the costs and manufacturing time of regeneratively cooled rocket engine components. High pressure/high temperature combustion chambers and nozzles must be regeneratively cooled to survive their operating environment, causing their design fabrication to be costly and time consuming due to the number of individual steps and different processes required. Under LCUSP, AM technologies in Sintered Laser Melting (SLM) GRCop-84 and Electron Beam Freeform Fabrication (EBF3) Inconel 625 have been significantly advanced, allowing the team to successfully fabricate a 25k-class regenerative chamber. Estimates of the costs and schedule of future builds indicate cost reductions and significant schedule reductions will be enabled by this technology. Characterization of the microstructural and mechanical properties of the SLM-produced GRCop-84, EBF3 Inconel 625 and the interface layer between the two has been performed and indicates the properties will meet the design requirements. The LCUSP chamber is to be tested with a previously demonstrated SLM injector in order to advance the Technology Readiness Level (TRL) and demonstrate the capability of the application of these processes. NASA is advancing these technologies to reduce cost and schedule for future engine applications and commercial needs.
77 FR 54482 - Allocation of Costs Under the Simplified Methods
2012-09-05
... cost of goods sold cash or trade discounts that taxpayers do not capitalize for book purposes (and... to adjust additional section 263A costs for cash or trade discounts described in Sec. 1.471-3(b... Allocation of Costs Under the Simplified Methods AGENCY: Internal Revenue Service (IRS), Treasury. ACTION...
2013-07-12
... CFR Parts 210 and 225 RIN 0584-AD84 Simplified Cost Accounting and Other Actions To Reduce Paperwork... Consolidated Appropriations Act, 2008. The changes extend simplified cost accounting and reporting procedures... nondiscretionary simplified cost accounting and reporting procedures established in the Consolidated Appropriations...
Vacuum chamber-free centrifuge with magnetic bearings.
Park, Cheol Hoon; Kim, Soohyun; Kim, Kyung-Soo
2013-09-01
Centrifuges are devices that separate particles of different densities and sizes through the application of a centrifugal force. If a centrifuge could be operated under atmospheric conditions, all vacuum-related components such as the vacuum chamber, vacuum pump, diffusion pump, and sealing could be removed from a conventional centrifuge system. The design and manufacturing procedure for centrifuges could then be greatly simplified to facilitate the production of lightweight centrifuge systems of smaller volume. Furthermore, the maintenance costs incurred owing to wear and tear due to conventional ball bearings would be eliminated. In this study, we describe a novel vacuum chamber-free centrifuge supported by magnetic bearings. We demonstrate the feasibility of the vacuum chamber-free centrifuge by presenting experimental results that verify its high-speed support capability and motoring power capacity.
FRESCO, a simplified code for cost analysis of fusion power plants
International Nuclear Information System (INIS)
Bustreo, C.; Casini, G.; Zollino, G.; Bolzonella, T.; Piovan, R.
2013-01-01
Highlights: • FRESCO is a code for rapid evaluation of the cost of electricity of a fusion power plant. • Parameters of the basic machine and unitary costs of components derived from ITER. • Power production components and plant power balance are extrapolated from PPCS. • A special effort is made in the investigation of the pulsed operation scenarios. • Technical and economical FRESCO results are compared with those of two PPCS models. -- Abstract: FRESCO (Fusion REactor Simplified COsts) is a code based on simplified models of physics, engineering and economical aspects of a TOKAMAK-like pulsed or steady-state fusion power plant. The experience coming from various aspects of ITER design, including selection of materials and operating scenarios, is exploited as much as possible. Energy production and plant power balance, including the recirculation requirements, are derived from two models of the PPCS European study, the helium cooled lithium/lead blanket model reactor (model AB) and the helium cooled ceramic one (model B). A detailed study of the availability of the power plant due, among others, to the replacement of plasma facing components, is also included in the code. The economics of the fusion power plant is evaluated through the levelized cost approach. Costs of the basic components are scaled from the corresponding values of the ITER project, the ARIES studies and SCAN model. The costs of plant auxiliaries, including those of the magnetic and electric systems, tritium plants, instrumentation, buildings and thermal energy storage if any, are recovered from ITER values and from those of other power plants. Finally, the PPCS models AB and B are simulated and the main results are reported in this paper
ROBucket: A low cost operant chamber based on the Arduino microcontroller.
Devarakonda, Kavya; Nguyen, Katrina P; Kravitz, Alexxai V
2016-06-01
The operant conditioning chamber is a cornerstone of animal behavioral research. Operant boxes are used to assess learning and motivational behavior in animals, particularly for food and drug reinforcers. However, commercial operant chambers cost several thousands of dollars. We have constructed the Rodent Operant Bucket (ROBucket), an inexpensive and easily assembled open-source operant chamber based on the Arduino microcontroller platform, which can be used to train mice to respond for sucrose solution or other liquid reinforcers. The apparatus contains two nose pokes, a drinking well, and a solenoid-controlled liquid delivery system. ROBucket can run fixed ratio and progressive ratio training schedules, and can be programmed to run more complicated behavioral paradigms. Additional features such as motion sensing and video tracking can be added to the operant chamber through the array of widely available Arduino-compatible sensors. The design files and programming code are open source and available online for others to use.
Cost effective electronics for proportional and drift chambers of 'EPECUR' experiment
International Nuclear Information System (INIS)
Alekseev, I.G.; Andreev, V.A.; Budkovsky, P.E.; Filimonov, E.A.; Golubev, V.V.; Kanavets, V.P.; Kats, M.M.; Koroleva, L.I.; Kovalev, A.I.; Kozlenko, N.G.; Kozlov, V.S.; Krivshich, A.G.; Kulikov, V.V.; Morozov, B.V.; Nesterov, V.M.; Novinsky, D.V.; Ryltsov, V.V.; Sadler, M.E.; Sakharov, V.A.; Soboyede, D.; Sulimov, A.D.; Sumachev, V.V.; Svirida, D.N.; Trautman, V.Yu.; Walker, E.; Watson, S.
2007-01-01
The 'EPECUR' experimental setup is under construction at beam line 322 of the ITEP proton synchrotron. The experiment requires several large area drift chambers to provide reasonable acceptance and fine-pitch proportional chambers for beam particle tracking. The total number of electronic channels is about 7000. A new compact and cost effective readout system for these gaseous detectors was designed, prototyped and tested in the last two years. It is based on modern technologies in analog and digital electronics and data transfer protocols. This paper presents the functional description of the whole DAQ system, including test results as an illustration of its performance
The thin-wall tube drift chamber operating in vacuum (prototype)
Alexeev, G. D.; Glonti, L. N.; Kekelidze, V. D.; Malyshev, V. L.; Piskun, A. A.; Potrbenikov, Yu. K.; Rodionov, V. K.; Samsonov, V. A.; Tokmenin, V. V.; Shkarovskiy, S. N.
2013-08-01
The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. "Self-centering" spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.
The thin-wall tube drift chamber operating in vacuum (prototype)
International Nuclear Information System (INIS)
Alexeev, G.D.; Glonti, L.N.; Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N.
2013-01-01
The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum
The thin-wall tube drift chamber operating in vacuum (prototype)
Energy Technology Data Exchange (ETDEWEB)
Alexeev, G.D. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Glonti, L.N., E-mail: glonti@sunse.jinr.ru [Joint Institute for Nuclear Research, Dubna (Russian Federation); Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation)
2013-08-01
The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.
Development of simplified decommissioning cost estimation code for nuclear facilities
International Nuclear Information System (INIS)
Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu
2010-01-01
The simplified decommissioning cost estimation code for nuclear facilities (DECOST code) was developed in consideration of features and structures of nuclear facilities and similarity of dismantling methods. The DECOST code could calculate 8 evaluation items of decommissioning cost. Actual dismantling in the Japan Atomic Energy Agency (JAEA) was evaluated; unit conversion factors used to calculate the manpower of dismantling activities were evaluated. Consequently, unit conversion factors of general components could be classified into three kinds. Weights of components and structures of the facility were necessary for calculation of manpower. Methods for evaluating weights of components and structures of the facility were studied. Consequently, the weight of components in the facility was proportional to the weight of structures of the facility. The weight of structures of the facility was proportional to the total area of floors in the facility. Decommissioning costs of 7 nuclear facilities in the JAEA were calculated by using the DECOST code. To verify the calculated results, the calculated manpower was compared with the manpower gained from actual dismantling. Consequently, the calculated manpower and actual manpower were almost equal. The outline of the DECOST code, evaluation results of unit conversion factors, the evaluation method of the weights of components and structures of the facility are described in this report. (author)
Papapostolou, Vasileios; Zhang, Hang; Feenstra, Brandon J.; Polidori, Andrea
2017-12-01
A state-of-the-art integrated chamber system has been developed for evaluating the performance of low-cost air quality sensors. The system contains two professional grade chamber enclosures. A 1.3 m3 stainless-steel outer chamber and a 0.11 m3 Teflon-coated stainless-steel inner chamber are used to create controlled aerosol and gaseous atmospheres, respectively. Both chambers are temperature and relative humidity controlled with capability to generate a wide range of environmental conditions. The system is equipped with an integrated zero-air system, an ozone and two aerosol generation systems, a dynamic dilution calibrator, certified gas cylinders, an array of Federal Reference Method (FRM), Federal Equivalent Method (FEM), and Best Available Technology (BAT) reference instruments and an automated control and sequencing software. Our experiments have demonstrated that the chamber system is capable of generating stable and reproducible aerosol and gas concentrations at low, medium, and high levels. This paper discusses the development of the chamber system along with the methods used to quantitatively evaluate sensor performance. Considering that a significant number of academic and research institutions, government agencies, public and private institutions, and individuals are becoming interested in developing and using low-cost air quality sensors, it is important to standardize the procedures used to evaluate their performance. The information discussed herein provides a roadmap for entities who are interested in characterizing air quality sensors in a rigorous, systematic and reproducible manner.
Robust Low Cost Liquid Rocket Combustion Chamber by Advanced Vacuum Plasma Process
Holmes, Richard; Elam, Sandra; Ellis, David L.; McKechnie, Timothy; Hickman, Robert; Rose, M. Franklin (Technical Monitor)
2001-01-01
Next-generation, regeneratively cooled rocket engines will require materials that can withstand high temperatures while retaining high thermal conductivity. Fabrication techniques must be cost efficient so that engine components can be manufactured within the constraints of shrinking budgets. Three technologies have been combined to produce an advanced liquid rocket engine combustion chamber at NASA-Marshall Space Flight Center (MSFC) using relatively low-cost, vacuum-plasma-spray (VPS) techniques. Copper alloy NARloy-Z was replaced with a new high performance Cu-8Cr-4Nb alloy developed by NASA-Glenn Research Center (GRC), which possesses excellent high-temperature strength, creep resistance, and low cycle fatigue behavior combined with exceptional thermal stability. Functional gradient technology, developed building composite cartridges for space furnaces was incorporated to add oxidation resistant and thermal barrier coatings as an integral part of the hot wall of the liner during the VPS process. NiCrAlY, utilized to produce durable protective coating for the space shuttle high pressure fuel turbopump (BPFTP) turbine blades, was used as the functional gradient material coating (FGM). The FGM not only serves as a protection from oxidation or blanching, the main cause of engine failure, but also serves as a thermal barrier because of its lower thermal conductivity, reducing the temperature of the combustion liner 200 F, from 1000 F to 800 F producing longer life. The objective of this program was to develop and demonstrate the technology to fabricate high-performance, robust, inexpensive combustion chambers for advanced propulsion systems (such as Lockheed-Martin's VentureStar and NASA's Reusable Launch Vehicle, RLV) using the low-cost VPS process. VPS formed combustion chamber test articles have been formed with the FGM hot wall built in and hot fire tested, demonstrating for the first time a coating that will remain intact through the hot firing test, and with
Chamber propagation physics for heavy ion fusion
International Nuclear Information System (INIS)
Callahan, D.A.
1995-01-01
Chamber transport is an important area of study for heavy ion fusion. Final focus and chamber-transport are high leverage areas providing opportunities to significantly decrease the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (approx-lt 0.003 torr), ballistic or nearly-ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (approx-gt.1 torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber then transporting it at small radius (∼ 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity
Chamber propagation physics for heavy ion fusion
International Nuclear Information System (INIS)
Callahan, D.A.
1996-01-01
Chamber transport is a key area of study for heavy ion fusion. Final focus and chamber transport are high leverage areas providing opportunities to decrease significantly the cost of electricity from a heavy ion fusion power plant. Chamber transport in two basic regimes is under consideration. In the low chamber density regime (below about 0.003 Torr), ballistic or nearly ballistic transport is used. Partial beam neutralization has been studied to offset the effects of beam stripping. In the high chamber density regime (above about 0.1 Torr), two transport modes (pinched transport and channel transport) are under investigation. Both involve focusing the beam outside the chamber and then transporting it at small radius (about 2 mm). Both high chamber density modes relax the constraints on the beam quality needed from the accelerator which will reduce the driver cost and the cost of electricity. (orig.)
International Nuclear Information System (INIS)
Logan, G.; Callahan-Miller, D.; Perkins, J.; Caporaso, G.; Tabak, M.; Moir, R.; Meier, W.; Bangerter, Roger; Lee, Ed
1998-01-01
Ion fast ignition, like laser fast ignition, can potentially reduce driver energy for high target gain by an order of magnitude, while reducing fuel capsule implosion velocity, convergence ratio, and required precisions in target fabrication and illumination symmetry, all of which should further improve and simplify IFE power plants. From fast-ignition target requirements, we determine requirements for ion beam acceleration, pulse-compression, and final focus for advanced accelerators that must be developed for much shorter pulses and higher voltage gradients than today's accelerators, to deliver the petawatt peak powers and small focal spots (∼100 (micro)m) required. Although such peak powers and small focal spots are available today with lasers, development of such advanced accelerators is motivated by the greater likely efficiency of deep ion penetration and deposition into pre-compressed 1000x liquid density DT cores. Ion ignitor beam parameters for acceleration, pulse compression, and final focus are estimated for two examples based on a Dielectric Wall Accelerator; (1) a small target with ρr ∼ 2 g/cm 2 for a small demo/pilot plant producing ∼40 MJ of fusion yield per target, and (2) a large target with ρr ∼ 10 g/cm 2 producing ∼1 GJ yield for multi-unit electricity/hydrogen plants, allowing internal T-breeding with low T/D ratios, >75 % of the total fusion yield captured for plasma direct conversion, and simple liquid-protected chambers with gravity clearing. Key enabling development needs for ion fast ignition are found to be (1) ''Close-coupled'' target designs for single-ended illumination of both compressor and ignitor beams; (2) Development of high gradient (>25 MV/m) linacs with high charge-state (q ∼ 26) ion sources for short (∼5 ns) accelerator output pulses; (3) Small mm-scale laser-driven plasma lens of ∼10 MG fields to provide steep focusing angles close-in to the target (built-in as part of each target); (4) beam space charge
Energy Technology Data Exchange (ETDEWEB)
Logan, G.; Callahan-Miller, D.; Perkins, J.; Caporaso, G.; Tabak, M.; Moir, R.; Meier, W.; Bangerter, Roger; Lee, Ed
1998-04-01
Ion fast ignition, like laser fast ignition, can potentially reduce driver energy for high target gain by an order of magnitude, while reducing fuel capsule implosion velocity, convergence ratio, and required precisions in target fabrication and illumination symmetry, all of which should further improve and simplify IFE power plants. From fast-ignition target requirements, we determine requirements for ion beam acceleration, pulse-compression, and final focus for advanced accelerators that must be developed for much shorter pulses and higher voltage gradients than today's accelerators, to deliver the petawatt peak powers and small focal spots ({approx}100 {micro}m) required. Although such peak powers and small focal spots are available today with lasers, development of such advanced accelerators is motivated by the greater likely efficiency of deep ion penetration and deposition into pre-compressed 1000x liquid density DT cores. Ion ignitor beam parameters for acceleration, pulse compression, and final focus are estimated for two examples based on a Dielectric Wall Accelerator; (1) a small target with {rho}r {approx} 2 g/cm{sup 2} for a small demo/pilot plant producing {approx}40 MJ of fusion yield per target, and (2) a large target with {rho}r {approx} 10 g/cm{sup 2} producing {approx}1 GJ yield for multi-unit electricity/hydrogen plants, allowing internal T-breeding with low T/D ratios, >75 % of the total fusion yield captured for plasma direct conversion, and simple liquid-protected chambers with gravity clearing. Key enabling development needs for ion fast ignition are found to be (1) ''Close-coupled'' target designs for single-ended illumination of both compressor and ignitor beams; (2) Development of high gradient (>25 MV/m) linacs with high charge-state (q {approx} 26) ion sources for short ({approx}5 ns) accelerator output pulses; (3) Small mm-scale laser-driven plasma lens of {approx}10 MG fields to provide steep focusing angles
Using simplified peer review processes to fund research: a prospective study
Herbert, Danielle L; Graves, Nicholas; Clarke, Philip; Barnett, Adrian G
2015-01-01
Objective To prospectively test two simplified peer review processes, estimate the agreement between the simplified and official processes, and compare the costs of peer review. Design, participants and setting A prospective parallel study of Project Grant proposals submitted in 2013 to the National Health and Medical Research Council (NHMRC) of Australia. The official funding outcomes were compared with two simplified processes using proposals in Public Health and Basic Science. The two simplified processes were: panels of 7 reviewers who met face-to-face and reviewed only the nine-page research proposal and track record (simplified panel); and 2 reviewers who independently reviewed only the nine-page research proposal (journal panel). The official process used panels of 12 reviewers who met face-to-face and reviewed longer proposals of around 100 pages. We compared the funding outcomes of 72 proposals that were peer reviewed by the simplified and official processes. Main outcome measures Agreement in funding outcomes; costs of peer review based on reviewers’ time and travel costs. Results The agreement between the simplified and official panels (72%, 95% CI 61% to 82%), and the journal and official panels (74%, 62% to 83%), was just below the acceptable threshold of 75%. Using the simplified processes would save $A2.1–$A4.9 million per year in peer review costs. Conclusions Using shorter applications and simpler peer review processes gave reasonable agreement with the more complex official process. Simplified processes save time and money that could be reallocated to actual research. Funding agencies should consider streamlining their application processes. PMID:26137884
Nar, Sevda Yeliz; Cakir, Altan
2018-02-01
Particles produced by nuclear decay, cosmic radiation and reactions can be identified through various methods. One of these methods that has been effective in the last century is the cloud chamber. The chamber makes visible cosmic particles that we are exposed to radiation per second. Diffusion cloud chamber is a kind of cloud chamber that is cooled by dry ice. This traditional model has some application difficulties. In this work, Peltier-based cloud chamber cooled by thermoelectric modules is studied. The new model provided uniformly cooled base of the chamber, moreover, it has longer lifetime than the traditional chamber in terms of observation time. This gain has reduced the costs which spent each time for cosmic particle observation. The chamber is an easy-to-use system according to traditional diffusion cloud chamber. The new model is portable, easier to make, and can be used in the nuclear physics experiments. In addition, it would be very useful to observe Muons which are the direct evidence for Lorentz contraction and time expansion predicted by Einsteins special relativity principle.
Multiwire proportional chamber development
Doolittle, R. F.; Pollvogt, U.; Eskovitz, A. J.
1973-01-01
The development of large area multiwire proportional chambers, to be used as high resolution spatial detectors in cosmic ray experiments is described. A readout system was developed which uses a directly coupled, lumped element delay-line whose characteristics are independent of the MWPC design. A complete analysis of the delay-line and the readout electronic system shows that a spatial resolution of about 0.1 mm can be reached with the MWPC operating in the strictly proportional region. This was confirmed by measurements with a small MWPC and Fe-55 X-rays. A simplified analysis was carried out to estimate the theoretical limit of spatial resolution due to delta-rays, spread of the discharge along the anode wire, and inclined trajectories. To calculate the gas gain of MWPC's of different geometrical configurations a method was developed which is based on the knowledge of the first Townsend coefficient of the chamber gas.
International Nuclear Information System (INIS)
Bottaro, Marcio
2012-01-01
A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)
Venturi vacuum systems for hypobaric chamber operations.
Robinson, R; Swaby, G; Sutton, T; Fife, C; Powell, M; Butler, B D
1997-11-01
Physiological studies of the effects of high altitude on man often require the use of a hypobaric chamber to simulate the reduced ambient pressures. Typical "altitude" chambers in use today require complex mechanical vacuum systems to evacuate the chamber air, either directly or via reservoir system. Use of these pumps adds to the cost of both chamber procurement and maintenance, and service of these pumps requires trained support personnel and regular upkeep. In this report we describe use of venturi vacuum pumps to perform the function of mechanical vacuum pumps for human and experimental altitude chamber operations. Advantages of the venturi pumps include their relatively low procurement cost, small size and light weight, ease of installation and plumbing, lack of moving parts, and independence from electrical power sources, fossil fuels and lubricants. Conversion of three hyperbaric chambers to combined hyper/hypobaric use is described.
Camp, Emma F.; Krause, Sophie-Louise; Santos, Lourianne M. F.; Naumann, Malik S.; Kikuchi, Ruy K. P.; Smith, David J.; Wild, Christian; Suggett, David J.
2015-01-01
Coral reefs are threatened worldwide, with environmental stressors increasingly affecting the ability of reef-building corals to sustain growth from calcification (G), photosynthesis (P) and respiration (R). These processes support the foundation of coral reefs by directly influencing biogeochemical nutrient cycles and complex ecological interactions and therefore represent key knowledge required for effective reef management. However, metabolic rates are not trivial to quantify and typically rely on the use of cumbersome in situ respirometry chambers and/or the need to remove material and examine ex situ, thereby fundamentally limiting the scale, resolution and possibly the accuracy of the rate data. Here we describe a novel low-cost in situ respirometry bag that mitigates many constraints of traditional glass and plexi-glass incubation chambers. We subsequently demonstrate the effectiveness of our novel “Flexi-Chamber” approach via two case studies: 1) the Flexi-Chamber provides values of P, R and G for the reef-building coral Siderastrea cf. stellata collected from reefs close to Salvador, Brazil, which were statistically similar to values collected from a traditional glass respirometry vessel; and 2) wide-scale application of obtaining P, R and G rates for different species across different habitats to obtain inter- and intra-species differences. Our novel cost-effective design allows us to increase sampling scale of metabolic rate measurements in situ without the need for destructive sampling and thus significantly expands on existing research potential, not only for corals as we have demonstrated here, but also other important benthic groups. PMID:26448294
Simplified radio-over-fiber transport systems with a low-cost multiband light source.
Chang, Ching-Hung; Peng, Peng-Chun; Lu, Hai-Han; Shih, Chine-Liang; Chen, Hwan-Wen
2010-12-01
In this Letter, low-cost radio-over-fiber (ROF) transport systems are proposed and experimentally demonstrated. By utilizing a laser diode (LD) and a local oscillator (LO) to generate coherent multiband optical carriers, as well as a self-composed wavelength selector to separate every two carriers for different ROF transport systems, no any other dedicated LD or electrical frequency upconverting circuit/process is needed in the central station (CS). Compared with current ROF systems, the required numbers of LDs, LOs, and mixers in a CS are significantly reduced. Reducing the number of components not only can simplify the network structure but can also reduce the volume and complexity of the relative logistics. To demonstrate the practice of the proposed ROF transport systems, clear eye diagrams and error-free transmission performance are experimentally presented.
Directional muon jet chamber for a muon collider (Groovy Chamber)
International Nuclear Information System (INIS)
Atac, M.
1996-10-01
A directional jet drift chamber with PAD readout is proposed here which can select vertex originated muons within a given time window and eliminate those muons which primarily originate upstream, using only a PAD readout. Drift time provides the Z-coordinate, and the center of gravity of charge distribution provides the r-ψ coordinates. Directionality at the trigger level is obtained by the timing measurement from the PAD hits within a given time window. Because of the long drift time between the bunch crossings, a muon collider enables one to choose a drift distance in the drift chamber as long as 50 cm. This is an important factor in reducing cost of drift chambers which have to cover relatively large areas
Simplified High-Power Inverter
Edwards, D. B.; Rippel, W. E.
1984-01-01
Solid-state inverter simplified by use of single gate-turnoff device (GTO) to commutate multiple silicon controlled rectifiers (SCR's). By eliminating conventional commutation circuitry, GTO reduces cost, size and weight. GTO commutation applicable to inverters of greater than 1-kilowatt capacity. Applications include emergency power, load leveling, drives for traction and stationary polyphase motors, and photovoltaic-power conditioning.
A low-cost touchscreen operant chamber using a Raspberry Pi™.
O'Leary, James D; O'Leary, Olivia F; Cryan, John F; Nolan, Yvonne M
2018-03-08
The development of a touchscreen platform for rodent testing has allowed new methods for cognitive testing that have been back-translated from clinical assessment tools to preclinical animal models. This platform for cognitive assessment in animals is comparable to human neuropsychological tests such as those employed by the Cambridge Neuropsychological Test Automated Battery, and thus has several advantages compared to the standard maze apparatuses typically employed in rodent behavioral testing, such as the Morris water maze. These include improved translation of preclinical models, as well as high throughput and the automation of animal testing. However, these systems are relatively expensive, which can impede progress for researchers with limited resources. Here we describe a low-cost touchscreen operant chamber based on the single-board computer, Raspberry Pi TM , which is capable of performing tasks similar to those supported by current state-of-the-art systems. This system provides an affordable alternative for cognitive testing in a touchscreen operant paradigm for researchers with limited funding.
Directory of Open Access Journals (Sweden)
Pallavi Sharma
2015-01-01
Full Text Available Aim: To evaluate the microleakage of a simplified etch-and-rinse adhesive bonded to pulp chamber dentin with water-wet bonding (WWB or ethanol-wet bonding (EWB with and without proanthocyanidins (PA application. Materials and Methods: Total 88 non-carious extracted human molar teeth were sectioned horizontally to expose the pulp chambers 1.5 mm coronal to the cemento-enamel junction. After the pulp tissue extirpation, canal orifices were enlarged and the root ends were sealed. The samples were randomly divided equally into following four groups according to the four bonding techniques performed using Adper Single Bond 2 [SB] adhesive (1 WWB; (2 EWB; (3 WWB and PA application [WWB + PA]; (4 EWB and PA application [EWB + PA]. Composite resin restorations were performed in all the pulp chambers. Total 20 samples from each group were subjected to microleakage evaluation, and two samples per group were assessed under scanning electron microscope for interfacial micromorphology. Results: The least microleakage score was observed in group 2 (EWB with similar results seen in group 4 (EWB + PA (P = 0.918. Group 2 (EWB showed significantly less microleakage than group 1 (WWB; P = 0.002 and group 3 (WWB + PA; P = 0.009. Group 4 (EWB + PA also depicted significantly reduced microleakage as compared with group 1 (WWB; P = 0.001 and group 3 (WWB + PA; P = 0.003. Conclusion: The use of EWB technique in a clinically relevant simplified dehydration protocol significantly reduced microleakage in simplified etch-and-rinse adhesive, Adper Single Bond 2, bonded to pulp chamber dentin. Application of PA had no significant effect on the microleakage of the adhesive bonded with either WWB or EWB.
The extension of the range of application of the CTC-800 climate chamber
DOLGIKH ARTEM; ALEXANDROVA NATALIA; POPOVA IRINA
2017-01-01
The article presents a research work aimed at potential improvement of the climate chamber CTC-800 to simplify the proof test of it and automate the processes it performs. To this end, the authors justify the need to apply the meter and controller of temperature and humidity of the MPR51 type as well as consider the functional MPR51-SHCH 4, its link with computer, and the compatibility of its operation with the climate chamber.
Chamber technology concepts for inertial fusion energy: Three recent examples
International Nuclear Information System (INIS)
Meier, W.R.; Moir, R.W.; Abdou, M.A.
1997-01-01
The most serious challenges in the design of chambers for inertial fusion energy (IFE) are 1) protecting the first wall from fusion energy pulses on the order of several hundred megajoules released in the form of x rays, target debris, and high energy neutrons, and 2) operating the chamber at a pulse repetition rate of 5-10 Hz (i.e., re-establishing, the wall protection and chamber conditions needed for beam propagation to the target between pulses). In meeting these challenges, designers have capitalized on the ability to separate the fusion burn physics from the geometry and environment of the fusion chamber. Most recent conceptual designs use gases or flowing liquids inside the chamber. Thin liquid layers of molten salt or metal and low pressure, high-Z gases can protect the first wall from x rays and target debris, while thick liquid layers have the added benefit of protecting structures from fusion neutrons thereby significantly reducing the radiation damage and activation. The use of thick liquid walls is predicted to 1) reduce the cost of electricity by avoiding the cost and down time of changing damaged structures, and 2) reduce the cost of development by avoiding the cost of developing a new, low-activation material. Various schemes have been proposed to assure chamber clearing and renewal of the protective features at the required pulse rate. Representative chamber concepts are described, and key technical feasibility issues are identified for each class of chamber. Experimental activities (past, current, and proposed) to address these issues and technology research and development needs are discussed
IFE chamber technology testing program in NIF and chamber development test plan
International Nuclear Information System (INIS)
Abdou, M.A.
1995-01-01
Issues concerning chamber technology testing program in NIF involving: criteria for evaluation/prioritization of experiments, engineering scaling requirements for test article design and material selection and R and D plan prior to NIF testing were addressed in this paper. In order to maximize the benefits of testing program in NIF, the testing in NIF should provide the experimental data relevant to DEMO design choice or to DEMO design predictive capability by utilizing engineering scaling test article designs. Test plans were developed for 2 promising chamber design concepts. Early testing in non-fusion/non-ignition prior to testing in ignition facility serves a critical role in chamber R and D test plans in order to reduce the risks and costs of the more complex experiments in NIF
Numerical Simulation of a Dual-Chamber Oscillating Water Column Wave Energy Converter
Directory of Open Access Journals (Sweden)
Dezhi Ning
2017-09-01
Full Text Available The performance of a dual-chamber Oscillating Water Column (OWC Wave Energy Converter (WEC is considered in the present study. The device has two sub-chambers with a shared orifice. A two-dimensional (2D fully nonlinear numerical wave flume based on the potential-flow theory and the time-domain higher-order boundary element method (HOBEM is applied for the simulation. The incident waves are generated by using the immerged sources and the air-fluid coupling influence is considered with a simplified pneumatic model. In the present study, the variation of the surface elevation and the water column volume in the two sub-chambers are investigated. The effects of the chamber geometry (i.e., the draft and breadth of two chambers on the surface elevation and the air pressure in the chamber are investigated, respectively. It is demonstrated that the surface elevations in the two sub-chambers are strongly dependent on the wave conditions. The larger the wavelength, the more synchronous motion of the two water columns in the two sub-chambers, thus, the lager the variation of the water column volume.
Duane, B G; Freeman, R; Richards, D; Crosbie, S; Patel, P; White, S; Humphris, G
2017-03-01
To commission dental services for vulnerable (special care) patient groups effectively, consistently and fairly an evidence base is needed of the costs involved. The simplified Case Mixed Tool (sCMT) can assess treatment mode complexity for these patient groups. To determine if the sCMT can be used to identify costs of service provision. Patients (n=495) attending the Sussex Community NHS Trust Special Care Dental Service for care were assessed using the sCMT. sCMT score and costs (staffing, laboratory fees, etc.) besides patient age, whether a new patient and use of general anaesthetic/intravenous sedation. Statistical analysis (adjusted linear regression modelling) compared sCMT score and costs then sensitivity analyses of the costings to age, being a new patient and sedation use were undertaken. Regression tables were produced to present estimates of service costs. Costs increased with sCMT total scale and single item values in a predictable manner in all analyses except for 'cooperation'. Costs increased with the use of IV sedation; with each rising level of the sCMT, and with complexity in every sCMT category, except cooperation. Costs increased with increase in complexity of treatment mode as measured by sCMT scores. Measures such as the sCMT can provide predictions of the resource allocations required when commissioning special care dental services. Copyright© 2017 Dennis Barber Ltd.
Limat, Samuel; Bracco-Nolin, Claire-Hélène; Legat-Fagnoni, Christine; Chaigneau, Loic; Stein, Ulrich; Huchet, Bernard; Pivot, Xavier; Woronoff-Lemsi, Marie-Christine
2006-06-01
The cost of chemotherapy has dramatically increased in advanced colorectal cancer patients, and the schedule of fluorouracil administration appears to be a determining factor. This retrospective study compared direct medical costs related to two different de Gramont schedules (standard vs. simplified) given in first-line chemotherapy with oxaliplatin or irinotecan. This cost-minimization analysis was performed from the French Health System perspective. Consecutive unselected patients treated in first-line therapy by LV5FU2 de Gramont with oxaliplatin (Folfox regimen) or with irinotecan (Folfiri regimen) were enrolled. Hospital and outpatient resources related to chemotherapy and adverse events were collected from 1999 to 2004 in 87 patients. Overall cost was reduced in the simplified regimen. The major factor which explained cost saving was the lower need for admissions for chemotherapy. Amount of cost saving depended on the method for assessing hospital stay. In patients treated by the Folfox regimen the per diem and DRG methods found cost savings of Euro 1,997 and Euro 5,982 according to studied schedules; in patients treated by Folfiri regimen cost savings of Euro 4,773 and Euro 7,274 were observed, respectively. In addition, travel costs were also reduced by simplified regimens. The robustness of our results was showed by one-way sensitivity analyses. These findings demonstrate that the simplified de Gramont schedule reduces costs of current first-line chemotherapy in advanced colorectal cancer. Interestingly, our study showed several differences in costs between two costing approaches of hospital stay: average per diem and DRG costs. These results suggested that standard regimen may be considered a profitable strategy from the hospital perspective. The opposition between health system perspective and hospital perspective is worth examining and may affect daily practices. In conclusion, our study shows that the simplified de Gramont schedule in combination with
A simplified hazard audit procedures guide
International Nuclear Information System (INIS)
Harrison, D.G.; Tabatabai, A.S.; Scott, W.B.; Murphy, K.J.
1991-02-01
As part of on-going technical support services to the US Department of Energy (DOE), Battelle Pacific Northwest Laboratory (PNL) has developed a simplified hazard audit procedures guide which enables cost-effective and timely assessment and characterization of the DOE nuclear (reactor and nonreactor) and non-nuclear facilities safety profile
Microstrip gas chamber on thin-film Pestov glass and micro gap chamber
International Nuclear Information System (INIS)
Gong, W.G.; Harris, J.W.; Wieman, H.
1994-07-01
The authors report developments of the Microstrip Gas Chamber on thin-film Pestov glass and the Micro Gap Chamber. By coating a thin-layer of low-resistive, electronically-conductive glass on various substrates (including quartz and ceramics), they built MSGCs of high gain stability and low leakage current. They were tested in Ar-CH 4 (10%) and He-C 2 H 6 (50%) gas mixtures. Energy resolutions of 17-20% were measured for 6keV x-rays. This design can make the choice of substrate less important, save the cost of ion-implantation, and use less glass material. Micro Gap Chamber was successfully tested in He-C 2 H 6 (50%) and Ar-C 2 H 6 (50%) gas mixtures. Energy resolutions of about 20% were obtained. Both detectors are expected to have high rate capability
The cost of simplifying air travel when modeling disease spread.
Directory of Open Access Journals (Sweden)
Justin Lessler
Full Text Available BACKGROUND: Air travel plays a key role in the spread of many pathogens. Modeling the long distance spread of infectious disease in these cases requires an air travel model. Highly detailed air transportation models can be over determined and computationally problematic. We compared the predictions of a simplified air transport model with those of a model of all routes and assessed the impact of differences on models of infectious disease. METHODOLOGY/PRINCIPAL FINDINGS: Using U.S. ticket data from 2007, we compared a simplified "pipe" model, in which individuals flow in and out of the air transport system based on the number of arrivals and departures from a given airport, to a fully saturated model where all routes are modeled individually. We also compared the pipe model to a "gravity" model where the probability of travel is scaled by physical distance; the gravity model did not differ significantly from the pipe model. The pipe model roughly approximated actual air travel, but tended to overestimate the number of trips between small airports and underestimate travel between major east and west coast airports. For most routes, the maximum number of false (or missed introductions of disease is small (<1 per day but for a few routes this rate is greatly underestimated by the pipe model. CONCLUSIONS/SIGNIFICANCE: If our interest is in large scale regional and national effects of disease, the simplified pipe model may be adequate. If we are interested in specific effects of interventions on particular air routes or the time for the disease to reach a particular location, a more complex point-to-point model will be more accurate. For many problems a hybrid model that independently models some frequently traveled routes may be the best choice. Regardless of the model used, the effect of simplifications and sensitivity to errors in parameter estimation should be analyzed.
APPLICATION OF SIMPLIFIED TAXATION SYSTEM IN CONSTRUCTION
Directory of Open Access Journals (Sweden)
O. S. Golubova
2011-01-01
Full Text Available Specificity concerning cost formation of construction work executed by entities of small business enterprises that use a simplified taxation system has a direct impact on the effectiveness of organization activity. Dozens of business entities applying various taxation systems are involved in the execution of the construction process. For this reason an inclusion of taxes in work cost may have a decisive influence on the selection of a contractor for an object construction.
Ionization chamber gradient effects in nonstandard beam configurations
International Nuclear Information System (INIS)
Bouchard, Hugo; Seuntjens, Jan; Carrier, Jean-Francois; Kawrakow, Iwan
2009-01-01
perturbation correction factors in nonstandard beam reference dosimetry, two possible ways to report absorbed dose are suggested: (1) Reporting average dose to the sensitive volume of the chamber filled with water, combined with removing the reference field implicit gradient effect when measuring output factors, and (2) reporting average dose to the chamber itself during output factor verifications. The first option could be adopted if clinical beam correction factors are negligible. The second option could simplify quality assurance procedures when correction factors are not negligible and have to be calculated using Monte Carlo simulations.
Design and construction of an inexpensive homemade plant growth chamber.
Katagiri, Fumiaki; Canelon-Suarez, Dario; Griffin, Kelsey; Petersen, John; Meyer, Rachel K; Siegle, Megan; Mase, Keisuke
2015-01-01
Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W) x 1.8 m (D) x 2 m (H), providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant growth chamber
Design and construction of an inexpensive homemade plant growth chamber.
Directory of Open Access Journals (Sweden)
Fumiaki Katagiri
Full Text Available Plant growth chambers produce controlled environments, which are crucial in making reproducible observations in experimental plant biology research. Commercial plant growth chambers can provide precise controls of environmental parameters, such as temperature, humidity, and light cycle, and the capability via complex programming to regulate these environmental parameters. But they are expensive. The high cost of maintaining a controlled growth environment is often a limiting factor when determining experiment size and feasibility. To overcome the limitation of commercial growth chambers, we designed and constructed an inexpensive plant growth chamber with consumer products for a material cost of $2,300. For a comparable growth space, a commercial plant growth chamber could cost $40,000 or more. Our plant growth chamber had outside dimensions of 1.5 m (W x 1.8 m (D x 2 m (H, providing a total growth area of 4.5 m2 with 40-cm high clearance. The dimensions of the growth area and height can be flexibly changed. Fluorescent lights with large reflectors provided a relatively spatially uniform photosynthetically active radiation intensity of 140-250 μmoles/m2/sec. A portable air conditioner provided an ample cooling capacity, and a cooling water mister acted as a powerful humidifier. Temperature, relative humidity, and light cycle inside the chamber were controlled via a z-wave home automation system, which allowed the environmental parameters to be monitored and programmed through the internet. In our setting, the temperature was tightly controlled: 22.2°C±0.8°C. The one-hour average relative humidity was maintained at 75%±7% with short spikes up to ±15%. Using the interaction between Arabidopsis and one of its bacterial pathogens as a test experimental system, we demonstrate that experimental results produced in our chamber were highly comparable to those obtained in a commercial growth chamber. In summary, our design of an inexpensive plant
HYLIFE-II reactor chamber design refinements
International Nuclear Information System (INIS)
House, P.A.
1994-06-01
Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams (Li 2 BeF 4 ) are used for shielding and blast protection of the chamber walls. The system is designed for a 6 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (>12 m/s) salt streams and also recover up to half of the dynamic head. Cost estimates for a 1 GWe and 2 GWe reactor chamber are presented
MIMO OTA Testing in Small Multi-Probe Anechoic Chamber Setups
DEFF Research Database (Denmark)
Llorente, Ines Carton; Fan, Wei; Pedersen, Gert F.
2016-01-01
OTA testing of MIMO capable terminals is often performed in large anechoic chambers, where planar waves impinging the test area are assumed. Furthermore, reflections from the chamber, and probe coupling are often considered negligible due to the large dimensions of the chamber. This paper...... investigates the feasibility of reducing the physical dimension of 2D multi-probe anechoic chamber setups for MIMO OTA testing, with the purpose of reducing the cost and space of the setup. In the paper, a channel emulation algorithm and chamber compensation technique are proposed for MIMO OTA testing in small...... anechoic chambers. The performance deterioration in a small anechoic chamber, i.e., with a ring radius of 0.5 m, is demonstrated via simulations....
Directory of Open Access Journals (Sweden)
Tatsuhiro Gotanda
2016-01-01
Full Text Available Radiochromic film dosimeters have a disadvantage in comparison with an ionization chamber in that the dosimetry process is time-consuming for creating a density-absorbed dose calibration curve. The purpose of this study was the development of a simplified method of creating a density-absorbed dose calibration curve from radiochromic film within a short time. This simplified method was performed using Gafchromic EBT3 film with a low energy dependence and step-shaped Al filter. The simplified method was compared with the standard method. The density-absorbed dose calibration curves created using the simplified and standard methods exhibited approximately similar straight lines, and the gradients of the density-absorbed dose calibration curves were −32.336 and −33.746, respectively. The simplified method can obtain calibration curves within a much shorter time compared to the standard method. It is considered that the simplified method for EBT3 film offers a more time-efficient means of determining the density-absorbed dose calibration curve within a low absorbed dose range such as the diagnostic range.
HYLIFE-II reactor chamber mechanical design: Update
International Nuclear Information System (INIS)
House, P.A.
1992-01-01
Mechanical design features of the reactor chamber for the HYLIFE-II inertial confinement fusion power plant are presented. A combination of oscillating and steady, molten salt streams (Li 2 BeF 4 ) are used for shielding and blast protection of the chamber walls. The system is designed for a 6 Hz repetition rate. Beam path clearing, between shots, is accomplished with the oscillating flow. The mechanism for generating the oscillating streams is described. A design configuration of the vessel wall allows adequate cooling and provides extra shielding to reduce thermal stresses to tolerable levels. The bottom portion of the reactor chamber is designed to minimize splash back of the high velocity (17 m/s) salt streams and also recover up to half of the dynamic head. Cost estimates for a 1 GW e and 2 GW e reactor chamber are presented
Lifetime survivability of contaminated target-chamber optics
International Nuclear Information System (INIS)
Rainer, F.; Anderson, A.; Burnham, A.; Milam, D.; Turner, R.
1996-11-01
Target chambers used for Inertial Confinement Fusion (ICF) expose laser optics to a very hostile environment, not only from high-fluence laser irradiation but also x-ray irradiation and particulate debris from targets and chamber wall materials. Expendable debris shields provide the first line of defense to more costly optics upstream in the laser beam path to contaminants generated within the target chamber. However, the replacement of a large number of debris shields is also an expensive proposition so that extending their usable lifetime within the chamber is important. We have conducted tests to show that optics can both be cleaned and damaged by laser irradiation at 355 nm after being contaminated with potential chamber-wall materials such as B 4 C and Al 2 O 3 . Such optics can survive from one to hundreds of laser shots, depending on degree of contamination and laser fluence levels. Similarly, we have studied the survivability of optics that have been exposed to direct contamination from representative target materials irradiated in the target chamber. We have also studied the effects on optics that were not directly exposed to targets, yet received secondary exposure from the above directly-exposed samples
Upgrades Of The ATLAS Muon Spectrometer With sMDT Chambers
Ferretti, Claudio; The ATLAS collaboration
2015-01-01
The Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer demonstrated that they provide very precise and robust tracking over large areas. Goals of ATLAS muon detector upgrades are to increase the acceptance for precision muon momentum measurement and triggering and to improve the rate capability of the muon chambers in the high-background regions when the LHC luminosity increases. Small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages with the MDTs, but have more than ten times higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, reducing cost and construction time considerably and improving the sense wire positioning accuracy to better than ten microns. Two sMDT chambers have been installed in 2014 to improve the mom...
International Nuclear Information System (INIS)
Knobloch, A.F.
1980-01-01
A simplified cost approximation for INTOR parameter sets in a narrow parameter range is shown. Plausible constraints permit the evaluation of the consequences of parameter variations on overall cost. (orig.) [de
Cleaning and air conditioning device for atmosphere in thermonuclear reactor chamber
International Nuclear Information System (INIS)
Ishida, Seiji.
1993-01-01
The device of the present invention removes tritium efficiently and attains ventilation and conditioning of a great amount of air flow. That is, there are disposed a humidity separator, a filter, a heater, a catalyst filled layer, a water jetting type humidifying heat insulation cooler and a cooler in this order from an inlet side (upstream) of contaminated room atmospheric gases. The catalyst filled layer, etc. are incorporated integrally into the ventilation air conditioning facility for ventilating air in the chamber of the thermonuclear reactor, to clean a tritium atmosphere at the same time. Accordingly, the device is made compact as a whole. A limit for the air flow rate owing to the use of the conventional catalyst tower and adsorbing tower is eliminated. Then a ventilating air conditioning for a great flow rate can be attained. Tritium is removed by cooling and dehumidification without using any adsorbent. Accordingly, an adsorbing tower is no more necessary and conventional regeneration operation is not required. As a result, space for installation is reduced, the system is simplified and the cost for construction and facility can be reduced. (I.S.)
ACPYPE - AnteChamber PYthon Parser interfacE.
Sousa da Silva, Alan W; Vranken, Wim F
2012-07-23
ACPYPE (or AnteChamber PYthon Parser interfacE) is a wrapper script around the ANTECHAMBER software that simplifies the generation of small molecule topologies and parameters for a variety of molecular dynamics programmes like GROMACS, CHARMM and CNS. It is written in the Python programming language and was developed as a tool for interfacing with other Python based applications such as the CCPN software suite (for NMR data analysis) and ARIA (for structure calculations from NMR data). ACPYPE is open source code, under GNU GPL v3, and is available as a stand-alone application at http://www.ccpn.ac.uk/acpype and as a web portal application at http://webapps.ccpn.ac.uk/acpype. We verified the topologies generated by ACPYPE in three ways: by comparing with default AMBER topologies for standard amino acids; by generating and verifying topologies for a large set of ligands from the PDB; and by recalculating the structures for 5 protein-ligand complexes from the PDB. ACPYPE is a tool that simplifies the automatic generation of topology and parameters in different formats for different molecular mechanics programmes, including calculation of partial charges, while being object oriented for integration with other applications.
Inertial confinement fusion reaction chamber and power conversion system study
International Nuclear Information System (INIS)
Maya, I.; Schultz, K.R.; Battaglia, J.M.
1984-09-01
GA Technologies has developed a conceptual ICF reactor system based on the Cascade rotating-bed reaction chamber concept. Unique features of the system design include the use of low activation SiC in a reaction chamber constructed of box-shaped tiles held together in compression by prestressing tendons to the vacuum chamber. Circulating Li 2 O granules serve as the tritium breeding and energy transport material, cascading down the sides of the reaction chamber to the power conversion system. The total tritium inventory of the system is 6 kg; tritium recovery is accomplished directly from the granules via the vacuum system. A system for centrifugal throw transport of the hot Li 2 O granules from the reaction chamber to the power conversion system has been developed. A number of issues were evaluated during the course of this study. These include the response of first-layer granules to the intense microexplosion surface heat flux, cost effective fabrication of Li 2 O granules, tritium inventory and recovery issues, the thermodynamics of solids-flow options, vacuum versus helium-medium heat transfer, and the tradeoffs of capital cost versus efficiency for alternate heat exchange and power conversion system option. The resultant design options appear to be economically competitive, safe, and environmentally attractive
Energy Technology Data Exchange (ETDEWEB)
Arbat, G.; Pujol, J.; Pelegri, M.; Puig-Bargues, J.; Duran-Ros, M.; Ramirez de Cartagena, F.
2013-05-01
The number of private gardens has increased in recent years, creating a more pleasant urban model, but not without having an environmental impact, including increased energy consumption, which is the focus of this study. The estimation of costs and energy consumption for the generic typology of private urban gardens is based on two simplifying assumptions: square geometry with surface areas from 25 to 500 m{sup 2} and hydraulic design with a single pipe. In total, eight sprinkler models have been considered, along with their possible working pressures, and 31 pumping units grouped into 5 series that adequately cover the range of required flow rates and pressures, resulting in 495 hydraulic designs repeated for two climatically different locations in the Spanish Mediterranean area (Girona and Elche). Mean total irrigation costs for the locality with lower water needs (Girona) and greater needs (Elche) were {epsilon} 2,974 ha{sup -}1 yr-1 and {epsilon}3,383 ha{sup -}1 yr{sup -}1, respectively. Energy costs accounted for 11.4% of the total cost for the first location, and 23.0% for the second. While a suitable choice of the hydraulic elements of the setup is essential, as it may provide average energy savings of 77%, due to the low energy cost in relation to the cost of installation, the potential energy savings do not constitute a significant incentive for the irrigation system design. The low efficiency of the pumping units used in this type of garden is the biggest obstacle and constraint to achieving a high quality energy solution. (Author) 32 refs.
Directory of Open Access Journals (Sweden)
G. Arbat
2013-02-01
Full Text Available The number of private gardens has increased in recent years, creating a more pleasant urban model, but not without having an environmental impact, including increased energy consumption, which is the focus of this study. The estimation of costs and energy consumption for the generic typology of private urban gardens is based on two simplifying assumptions: square geometry with surface areas from 25 to 500 m2 and hydraulic design with a single pipe. In total, eight sprinkler models have been considered, along with their possible working pressures, and 31 pumping units grouped into 5 series that adequately cover the range of required flow rates and pressures, resulting in 495 hydraulic designs repeated for two climatically different locations in the Spanish Mediterranean area (Girona and Elche. Mean total irrigation costs for the locality with lower water needs (Girona and greater needs (Elche were € 2,974 ha-1 yr-1 and € 3,383 ha-1 yr-1, respectively. Energy costs accounted for 11.4% of the total cost for the first location, and 23.0% for the second. While a suitable choice of the hydraulic elements of the setup is essential, as it may provide average energy savings of 77%, due to the low energy cost in relation to the cost of installation, the potential energy savings do not constitute a significant incentive for the irrigation system design. The low efficiency of the pumping units used in this type of garden is the biggest obstacle and constraint to achieving a high quality energy solution.
When to Perform Antenna Measurements in a Near-Field Range or a Short Tapered Chamber
2017-03-01
results for future antennas under test in the most cost-effective manner (man-hours, custom mount, etc.) 15. SUBJECT TERMS electromagnetic, chamber...to obtain the results for future antennas under test (AUTs) in the most cost-effective manner (man-hours, custom mounting, etc.). The NFR and...the most cost-effective manner to obtain AUT data be established for either the NFR or tapered anechoic chamber. The NFR can obtain planar
Low-Cost and Light-Weight Transpiration-Cooled Thrust Chambers, Phase I
National Aeronautics and Space Administration — The proposed effort aims to evaluate the feasibility of using transpiration-cooled Titanium as the primary material in small-scale thrust chambers for in-space...
A simplified approach to evaluating severe accident source term for PWR
International Nuclear Information System (INIS)
Huang, Gaofeng; Tong, Lili; Cao, Xuewu
2014-01-01
Highlights: • Traditional source term evaluation approaches have been studied. • A simplified approach of source term evaluation for 600 MW PWR is studied. • Five release categories are established. - Abstract: For early design of NPPs, no specific severe accident source term evaluation was considered. Some general source terms have been used for some NPPs. In order to implement a best estimate, a special source term evaluation should be implemented for an NPP. Traditional source term evaluation approaches (mechanism approach and parametric approach) have some difficulties associated with their implementation. The traditional approaches are not consistent with cost-benefit assessment. A simplified approach for evaluating severe accident source term for PWR is studied. For the simplified approach, a simplified containment event tree is established. According to representative cases selection, weighted coefficient evaluation, computation of representative source term cases and weighted computation, five containment release categories are established, including containment bypass, containment isolation failure, containment early failure, containment late failure and intact containment
Simulation of Chamber Transport for Heavy-Ion-Fusion Drivers
International Nuclear Information System (INIS)
Sharp, W.M.; Callahan, D.A.; Tabak, M.; Yu, S.S.; Peterson, P.F.; Rose, D.V.; Welch, D.R.
2003-01-01
The heavy-ion fusion (HIF) community recently developed a power-plant design that meets the various requirements of accelerators, final focus, chamber transport, and targets. The point design is intended to minimize physics risk and is certainly not optimal for the cost of electricity. Recent chamber-transport simulations, however, indicate that changes in the beam ion species, the convergence angle, and the emittance might allow more-economical designs
Chamber-transport simulation results for heavy-ion fusion drivers
International Nuclear Information System (INIS)
Sharp, W M; Callahan, D A; Tabak, M; Yu, S S; Peterson, P F; Rose, D V; Welch, D R
2004-01-01
The heavy-ion fusion (HIF) community recently developed a power-plant design that meets the various requirements of accelerators, final focus, chamber transport, and targets. The point design is intended to minimize physics risk and is certainly not optimal for the cost of electricity. Recent chamber-transport simulations, however, indicate that changes in the beam ion species, the convergence angle, and the emittance might allow more-economical designs
SIMULATION OF CHAMBER TRANSPORT FOR HEAVY-ION FUSION DRIVERS
International Nuclear Information System (INIS)
Sharp, W M; Callahan, D A; Tabak, M; Yu, S S; Peterson, P F; Rose, D V; Welch, D R
2004-01-01
The heavy-ion fusion (HIF) community recently developed a power-plant design that meets the various requirements of accelerators, final focus, chamber transport, and targets. The point design is intended to minimize physics risk and is certainly not optimal for the cost of electricity. Recent chamber-transport simulations, however, indicate that changes in the beam ion species, the convergence angle, and the emittance might allow more-economical designs
Energy Technology Data Exchange (ETDEWEB)
Joo, Youngdo; Hwang, Ilmoon; Park, Sungju [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of); Kim, Changbum, E-mail: chbkim@postech.ac.k [Pohang Accelerator Laboratory, Pohang University of Science and Technology, Pohang 790-784 (Korea, Republic of)
2011-05-11
It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S{sub 21}) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.
International Nuclear Information System (INIS)
Joo, Youngdo; Hwang, Ilmoon; Park, Sungju; Kim, Changbum
2011-01-01
It is known that the position reading obtained from the beam position monitor (BPM) mounted at the storage ring can be corrupted by the resonance mode. We carried out a three dimensional finite-difference time-domain (FDTD) simulation of vacuum chambers of the storage ring of the Pohang Light Source (PLS) without simplified modeling to measure the frequencies of resonance modes excited in the vacuum chamber. The frequencies of resonance modes obtained by the eigenmode simulation are well matched with the peak frequencies of RF transmission scattering matrix (S 21 ) graph of sector vacuum chamber measured using a network analyzer. It is found that a transverse electric (TE) resonance mode exists in the operation frequency band of BPM and the vertically oriented electric field of TE resonance mode is linked to the BPM position reading noise. Based on this study, we can easily design a vacuum chamber free from the BPM position reading noise caused by the TE resonance mode.
Lifetime tests for MAC vertex chamber
International Nuclear Information System (INIS)
Nelson, H.
1986-01-01
A vertex chamber for MAC was proposed in fall 1983 to increase precision in the measurement of the B hadron and tau lepton lifetimes. The chamber had to be placed within the existing central drift chamber, making access for repairs difficult and costly. Therefore for detector elements thin-walled aluminized mylar drift tubes (straws) were used because of their simplicity and robustness. The diameter of the drift tubes was 6.9 mm. The radial extent of the proposed chamber was from 3 cm to 10 cm, the inner wall of the central drift. It was clear that radiation levels, from synchrotron x-rays and overfocussed electrons, were potentially high. Since the drift distance is short in the straws, it was desirable to operate them at the highest possible gas gain, to achieve the best spatial resolution. There was a likelihood of drawing large currents in the chamber and thus causing radiation damage. Therefore a study of radiation hardness under the conditions of their proposed design was undertaken. In tests, argon-hydrocarbon mixtures consistently became unusable at ∼0.05 C/cm collected charge, due to anode buildup. Argon-CO 2 mixtures, while underquenched, were operational to 0.25 C/cm, at which point loss of cathode material became intolerable. Argon-xenon-CO 2 proved to be quenched as well as argon-hydrocarbons, but was limited by cathode damage. The MAC vertex chamber has operated at a distance of 4.6 cm from the e + e - interaction point at PEP for two years and has shown no aging effects
Directory of Open Access Journals (Sweden)
Ialomiţianu, G.
2010-12-01
Full Text Available The application of the complex accounting and fiscal systems represents an administrative burden for small and medium enterprises. This situation generates huge costs, too hard to bear by legal entities. The introduction of simplified accounting and fiscal systems has to represent a priority for every state, because it triggers the reduction of the administrative burden. The fiscal systems based on low taxation should not be confused with simplified fiscal systems. Many a time, enterprises prefer simplified systems, even if they do not totally comply with the fiscal equity principle.
DEFF Research Database (Denmark)
Marcell, S.A.; Balazs, A.; Emese, A.
2013-01-01
Prediction of the prognosis of breast cancer in routine histologic specimens using a simplified, low-cost gene expression signature Background: Grade 2 breast carcinomas do not form a uniform prognostic group. Aim: To extend the number of patients and the investigated genes of a previously...... grade 2 breast carcinomas into prognostic groups. Gene expression was investigated by polymerase chain reaction in 249 formalin-fixed, paraffin-embedded breast tumors. The results were correlated with relapse-free survival. Results: Histologically grade 2 carcinomas were split into good and a poor...... identified prognostic signature described by the authors that reflect chromosomal instability in order to refine characterization of grade 2 breast cancers and identify driver genes. Methods: Using publicly available databases, the authors selected 9 target and 3 housekeeping genes that are capable to divide...
Experience with simplified inelastic analysis of piping designed for elevated temperature service
International Nuclear Information System (INIS)
Severud, L.K.
1980-03-01
Screening rules and preliminary design of FFTF piping were developed in 1974 based on expected behavior and engineering judgment, approximate calculations, and a few detailed inelastic analyses of pipelines. This paper provides findings from six additional detailed inelastic analyses with correlations to the simplified analysis screening rules. In addition, simplified analysis methods for treating weldment local stresses and strains as well as fabrication induced flaws are described. Based on the FFTF experience, recommendations for future Code and technology work to reduce design analysis costs are identified
SiMA: A simplified migration assay for analyzing neutrophil migration.
Weckmann, Markus; Becker, Tim; Nissen, Gyde; Pech, Martin; Kopp, Matthias V
2017-07-01
three non-asthmatic patients gives a first hint to the capability of SiMA assay in the context of migration based diagnostics. Using SiMA we were able to identify typical migration profiles of the chemoattractants IL-8, fMLP, and LTB 4 , the effect of the matrices FN versus HEM as well as the response to different medications, that is, Prednisolone induced a change of direction of migrating neutrophils in FN but no such effect was observed in human placental matrix. In addition, neutrophils of asthmatic individuals showed an increased proportion of cells migrating toward the vehicle. With the SiMA platform we presented a simplified but yet flexible platform for cost-effective tracking and quantification of neutrophil migration. The introduced method is based on a simple microscopic video stage, standardized, commercially available, µ-fluidic migration chambers and automated image analysis, and track validation software. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
Circuit for current measures from ionization chambers
International Nuclear Information System (INIS)
Mello, F.L.V. de; Oliveira, A.H. de; Rezende, R.S.
1992-01-01
The design and the specifications of an ammeters of low cost for small current, IOE-14 Ampere, from ionization chambers or others transducers used in nuclear instrumentation are described. Special attention is given to the integrated electronic components, available in the brazilian market. (C.G.C.)
ACPYPE - AnteChamber PYthon Parser interfacE
Directory of Open Access Journals (Sweden)
Sousa da Silva Alan W
2012-07-01
Full Text Available Abstract Background ACPYPE (or AnteChamber PYthon Parser interfacE is a wrapper script around the ANTECHAMBER software that simplifies the generation of small molecule topologies and parameters for a variety of molecular dynamics programmes like GROMACS, CHARMM and CNS. It is written in the Python programming language and was developed as a tool for interfacing with other Python based applications such as the CCPN software suite (for NMR data analysis and ARIA (for structure calculations from NMR data. ACPYPE is open source code, under GNU GPL v3, and is available as a stand-alone application at http://www.ccpn.ac.uk/acpype and as a web portal application at http://webapps.ccpn.ac.uk/acpype. Findings We verified the topologies generated by ACPYPE in three ways: by comparing with default AMBER topologies for standard amino acids; by generating and verifying topologies for a large set of ligands from the PDB; and by recalculating the structures for 5 protein–ligand complexes from the PDB. Conclusions ACPYPE is a tool that simplifies the automatic generation of topology and parameters in different formats for different molecular mechanics programmes, including calculation of partial charges, while being object oriented for integration with other applications.
Energy Technology Data Exchange (ETDEWEB)
Bottaro, Marcio
2012-07-01
A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)
Small-sized reverberation chamber for the measurement of sound absorption
International Nuclear Information System (INIS)
Rey, R. del; Alba, J.; Bertó, L.; Gregori, A.
2017-01-01
This paper presents the design, construction, calibration and automation of a reverberation chamber for small samples. A balance has been sought between reducing sample size, to reduce the manufacturing costs of materials, and finding the appropriate volume of the chamber, to obtain reliable values at high and mid frequencies. The small-sized reverberation chamber, that was built, has a volume of 1.12 m3 and allows for the testing of samples of 0.3 m2. By using diffusers, to improve the diffusion degree, and automating measurements, we were able to improve the reliability of the results, thus reducing test errors. Several comparison studies of the measurements of the small-sized reverberation chamber and the standardised reverberation chamber are shown, and a good degree of adjustment can be seen between them, within the range of valid frequencies. This paper presents a small laboratory for comparing samples and making decisions before the manufacturing of larger sizes. [es
International piping benchmarks: Use of simplified code PACE 2
Energy Technology Data Exchange (ETDEWEB)
Boyle, J; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom)
1979-06-01
This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)
International piping benchmarks: Use of simplified code PACE 2
International Nuclear Information System (INIS)
Boyle, J.; Spence, J.; Blundell, C.
1979-01-01
This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost. (author)
Hill, Joanne E.; Black, J. Kevin; Emmett, Thomas J.; Enoto, Teruaki; Jahoda, Keith M.; Kaaret, Philip; Nolan, David S.; Tamagawa, Toru
2014-01-01
The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.
Thermal System Upgrade of the Space Environment Simulation Test Chamber
Desai, Ashok B.
1997-01-01
The paper deals with the refurbishing and upgrade of the thermal system for the existing thermal vacuum test facility, the Space Environment Simulator, at NASA's Goddard Space Flight Center. The chamber is the largest such facility at the center. This upgrade is the third phase of the long range upgrade of the chamber that has been underway for last few years. The first phase dealt with its vacuum system, the second phase involved the GHe subsystem. The paper describes the considerations of design philosophy options for the thermal system; approaches taken and methodology applied, in the evaluation of the remaining "life" in the chamber shrouds and related equipment by conducting special tests and studies; feasibility and extent of automation, using computer interfaces and Programmable Logic Controllers in the control system and finally, matching the old components to the new ones into an integrated, highly reliable and cost effective thermal system for the facility. This is a multi-year project just started and the paper deals mainly with the plans and approaches to implement the project successfully within schedule and costs.
International Nuclear Information System (INIS)
Jilbert, P.H.
1975-01-01
The invention concerns ionization chambers with particular reference to air-equivalent ionization chambers. In order to ensure that similar chambers have similar sensitivities and responses the surface of the chamber bounding the active volume carries a conducting material, which may be a colloidal graphite, arranged in the form of lines so that the area of the conducting material occupies only a small proportion of the area of said surface. (U.S.)
Gradl, Paul R.; Greene, Sandy; Protz, Chris
2017-01-01
NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA’s Marshall Space Flight Center (MSFC) has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. MSFC’s efforts include a 4,000 pounds-force thrust liquid oxygen/methane (LOX/CH4) combustion chamber. Small thrust chambers for 1,200 pounds-force LOX/hydrogen (H2) applications have also been designed and fabricated with SLM GRCop-84. Similar chambers have also completed development with an Inconel 625 jacket bonded to the GRCop-84 material, evaluating direct metal deposition (DMD) laser- and arc-based techniques. The same technologies for these lower thrust applications are being applied to 25,000-35,000 pounds-force main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.
FEATURES OF TECHNO-ECONOMIC CALCULATION OF COMMERCIAL COOLING CHAMBERS
Directory of Open Access Journals (Sweden)
M. Khmelniuk
2017-10-01
Full Text Available The article touches upon the design and calculation of trade objects refrigerating chambers. The influence of the cost of various groups of components and equipment on the final cost of the camera is analyzed. The influence of such factors as noise, fire safety and location of equipment during operation and installation is described. Recommendations are given on the choice of components in the design.
Performance optimization of 20 cm xenon ion thruster discharge chamber
International Nuclear Information System (INIS)
Chen Juanjuan; Zhang Tianping; Jia Yanhui; Li Xiaoping
2012-01-01
This paper describes the performance of the LIPS-200 ion thruster discharge chamber which was developed by Lanzhou Institute of Physics. Based on the discharge chamber geometric configuration and magnetic field, the completely self-consistent analytical model is utilized to discuss performance optimization of the discharge chamber of the LIPS-200. The thrust is enhanced from 40 mN up to 60 mN at rated impulse and efficiency. The results show that the 188.515 W/A beam ion production cost at a propellant flow rate of 2.167 × 10 17 m -3 requires that the thruster runs at a discharge current of 6.9 A to produce 1.2 A ion beam current. Also, during the process of LIPS-200 ion thruster discharge chamber performance optimization, the sheath potential is always within 3.80 ∼ 6.65 eV. (authors)
International Nuclear Information System (INIS)
Cox, M.E.; Cox, M.E.
1975-01-01
An environmental chamber is described which enables an operator's hands to have direct access within the chamber without compromising a special atmosphere within such chamber. A pair of sleeves of a flexible material are sealed to the chamber around associated access apertures and project outwardly from such chamber. Each aperture is closed by a door which is openable from within the sleeve associated therewith so that upon an operator inserting his hand and arm through the sleeve, the operator can open the door to have access to the interior of the chamber. A container which is selectively separable from the remainder of the chamber is also provided to allow objects to be transferred from the chamber without such objects having to pass through the ambient atmosphere. An antechamber permitting objects to be passed directly into the chamber from the ambient atmosphere is included. (auth)
Potentiality of low cost environmentally friendly chamber for storage of irradiated potato and onion
International Nuclear Information System (INIS)
Roy, S.K.; Chakrabarti, A.K.; Pal, R.K.
1994-01-01
Potatoes and onions are two important horticultural commodities in India. Refrigeration is an expensive system and it is beyond the means of the poor, small and marginal farmers. Based on the principle of direct evaporative cooling, the scientists of the Indian Agricultural Research Institute developed a zero energy cool chamber. The zero energy cool chamber was tried at different locations in the country and was found to be very effective in increasing the shelf life of the fruits and vegetables and decreasing the physiological loss in weight
Gradl, Paul R.; Greene, Sandy Elam; Protz, Christopher S.; Ellis, David L.; Lerch, Bradley A.; Locci, Ivan E.
2017-01-01
NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder-bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. NASA's efforts include a 4K lbf thrust liquid oxygen/methane (LOX/CH4) combustion chamber and subscale thrust chambers for 1.2K lbf LOX/hydrogen (H2) applications that have been designed and fabricated with SLM GRCop-84. The same technologies for these lower thrust applications are being applied to 25-35K lbf main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.
SBWR: A simplified boiling water reactor
International Nuclear Information System (INIS)
Duncan, J.D.; Sawyer, C.D.; Lagache, M.P.
1987-01-01
An advanced light water reactor concept is being developed for possible application in the 1990's. The concept, known as SBWR is a boiling water reactor which uses natural circulation to provide flow to the reactor core. In an emergency, a gravity driven core cooling system is used. The reactor is depressurized and water from an elevated suppression pool flows by gravity to the reactor vessel to keep the reactor core covered. The concept also features a passive containment cooling system in which water flows by gravity to cool the suppression pool wall. No operator action is required for a period of at least three days. Use of these and other passive systems allows the elimination of emergency diesel generators, core cooling pumps and heat removal pumps which is expected to simplify the plant design, reduce costs and simplify licensing. The concept is being developed by General Electric, Bechtel and the Massachusetts Institute of Technology supported by the Electric Power Research Institute and the United States Department of Energy in the United States. In Japan, The Japan Atomic Power Company has a great interest in this concept
Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.
DESIGNING HYDRAULIC AIR CHAMBER IN WATER TRANSMISSION SYSTEMS USING GENETIC ALGORITHM
Directory of Open Access Journals (Sweden)
Abdorahim Jamal
2016-09-01
Full Text Available Transient flow control in Water Transmission Systems (WTS is one of the requirements of designing these systems. Hence, among control equipment, air chambers offer the best solution to control transient flow effects, i.e. both prevents water column separation and absorbs pressure increase. It is essential to carry out an accurate and optimized design of air chambers, not only due to high costs of their manufacturing but also their important protective role. Accordingly, hydraulic design parameters comprise tank volume, diameter of nozzle and coefficients of inflow and outflow of nozzle. In this paper, it is intended to optimize these parameters in order to minimize manufacturing costs. On the other hand, maximum and minimum pressures in main pipeline are considered as constraints which shall fall in allowed range. Therefore, a model has been developed which is a combination of a hydraulic simulation model of WTS and an optimization model based on genetic algorithm. This model is first applied to WTS of Dehgolan-Ghorveh plain as a case study. Results of this research demonstrate that based on suggested model, negative wave creation and pressure increase in pipeline is prevented as well as decrease in manufacturing costs of air chamber.
Leferink, Frank Bernardus Johannes
2009-01-01
A test chamber for measuring electromagnetic radiation emitted by an apparatus to be tested or for exposing an apparatus to be tested to an electromagnetic radiation field. The test chamber includes a reverberation chamber made of a conductive tent fabric. To create a statistically uniform field in
International Nuclear Information System (INIS)
Viola, E.; Zimbardi, F.; Valerio, V.; Nanna, F.; Battafarano, A.
2013-01-01
Highlights: ► A two-chamber reactor is proposed to improve bioethanol production. ► Hydrolysis and fermentation can be made simultaneous at different temperatures. ► The residue of lignin can be easily separated at the end of the process. -- Abstract: A special type of bioreactor was designed and tested in order to improve the bioethanol production from lignocellulosic materials via enzymatic hydrolysis and fermentation. The reactor consists of two chambers kept at different temperatures and separated by a porous medium, through which the solutes can diffuse. The reactor was tested using as substrate wheat straw previously steam exploded and detoxified. The yields of cellulose hydrolysis and glucose fermentation obtained using this reactor were compared to those obtained by simultaneous enzymatic hydrolysis and fermentation (SSF) carried out in only one vessel. The results showed that a significant increase in the ethanol yield (20%) can be achieved by using this bioreactor. An additional advantage of the reactor is the confinement of the solid lignin in one chamber, allowing a simplified separation process between broth and unreacted residue.
Development of Aluminium Vacuum Chambers for the LHC Experiments at CERN
Gallilee, M; Costa-Pinto, P; Lepeule, P; Perez-Espinos, J; Marques Antunes Ferreira, L; Prever-Loiri, L; Sapountzis, A
2014-01-01
Beam losses may cause activation of vacuum chamber walls, in particular those of the Large Hadron Collider (LHC) experiments. For the High Luminosity (HL-LHC), the activation of such vacuum chambers will increase. It is therefore necessary to use a vacuum chamber material which interacts less with the circulating beam. While beryllium is reserved for the collision point, a good compromise between cost, availability and transparency is obtained with aluminium alloys; such materials are a preferred choice with respect to austenitic stainless steel. Manufacturing a thin-wall aluminium vacuum chamber presents several challenges as the material grade needs to be machinable, weldable, leak-tight for small thicknesses, and able to withstand heating to 250°C for extended periods of time. This paper presents some of the technical challenges during the manufacture of these vacuum chambers and the methods for overcoming production difficulties, including surface treatments and Non-Evaporable Getter (NEG) thin-film coat...
Formation of decontamination cost calculation model for severe accident consequence assessment
International Nuclear Information System (INIS)
Silva, Kampanart; Promping, Jiraporn; Okamoto, Koji; Ishiwatari, Yuki
2014-01-01
In previous studies, the authors developed an index “cost per severe accident” to perform a severe accident consequence assessment that can cover various kinds of accident consequences, namely health effects, economic, social and environmental impacts. Though decontamination cost was identified as a major component, it was taken into account using simple and conservative assumptions, which make it difficult to have further discussions. The decontamination cost calculation model was therefore reconsidered. 99 parameters were selected to take into account all decontamination-related issues, and the decontamination cost calculation model was formed. The distributions of all parameters were determined. A sensitivity analysis using the Morris method was performed in order to identify important parameters that have large influence on the cost per severe accident and large extent of interactions with other parameters. We identified 25 important parameters, and fixed most negligible parameters to the median of their distributions to form a simplified decontamination cost calculation model. Calculations of cost per severe accident with the full model (all parameters distributed), and with the simplified model were performed and compared. The differences of the cost per severe accident and its components were not significant, which ensure the validity of the simplified model. The simplified model is used to perform a full scope calculation of the cost per severe accident and compared with the previous study. The decontamination cost increased its importance significantly. (author)
Alberta Chamber of Resources: 1998 in review
International Nuclear Information System (INIS)
Simpson, R.
1999-01-01
Several key initiatives taken by the Alberta Chamber of Resources during 1998 are described. Among these initiatives special mention is made of strengthening the relations between the Chamber and the University of Calgary and the University of Alberta through regular contributions to business plan reviews, scholarships, and advisory committees. Working with the Department of Energy on a range of issues involving the environment, taxation, and mineral rights tenure is an area the ACR is involved. Hosting a workshop on the economic and social values and trade-offs in the green areas of Alberta and working with the University Alberta regarding the development of an advisory committee on forest resource valuation is another area. Strategizing the Oil Sands Task Force to strengthen it in the areas of industrial coordination, by-product utilization, the creation niche markets and product quality and investigating, through the Black Oil Pipeline Steering Committee, transportation, technological and marketing issues related to the oil sands are other interests. In the Mineral Sector, the Chamber facilitated discussions towards a Non-Energy Minerals and Mines Act, which among other long-range beneficial effects, prompted the provincial government to provide an additional $ 1.5 million to the Alberta Geological Survey. In the Utilities Sector, the Chamber continued to bring together various parties to work on common challenges and opportunities. Much interest has been generated also on upgraders and research facilitated by the Chamber either with members of the Alberta Research Council, or the National Centre for Upgrading Technology or similar organizations. This kind of facilitation helps the Chamber's member companies to realize cost reductions in development and application of new technologies
Climatic chamber for plant physiology: a new project concept
International Nuclear Information System (INIS)
Materassi, A.; Fasano, G.; Arca, A.
2005-01-01
The two climatic chambers proposed here were designed and built for both general environmental physiology and specific studies on the effect of ultraviolet radiation on plants. The two chambers differ only for the fact that one of them, in addition to solar spectrum lamps, also has lamps which emit UV-B radiation. The environmental parameters taken into consideration are: luminous and UV-B radiation, air temperature and humidity, ozone and carbon dioxide concentration and air movement. Radiation can be continuously regulated, thus permitting simulation of twilight increasing and decreasing at the beginning and end of the photoperiod. Temperature cycles can be imposed between 5 and 40 deg C, while, for relative humidity, values can be imposed between 30% and 80%. Concentration of O3 can be maintained at values much lower than 0.1 ppm, the maximum value compatible with biological activity; CO2 concentration can be brought up to 3,000 ppm. Air movement inside the chambers is assured by ventilators and aspirators mounted on the devices which carry out regulation of the other environmental parameters. The controls of the various quantities are performed using medium-low cost commercial devices, while high level software manages them. In this way, good quality control of the environmental parameters is obtained with a much lower construction cost compared to other climatic chambers. Moreover, the use of commercial actuators permits easier and more immediate maintenance. Functionality tests, carried out both in transient and in steady state, have demonstrated a complete correspondence between project specifications and obtained results [it
Design of a prototype tri-electrode ion-chamber for megavoltage X-ray imaging
International Nuclear Information System (INIS)
Samant, Sanjiv S.; Gopal, Arun; Jain, Jinesh; Xia Junyi; DiBianca, Frank A.
2007-01-01
High-energy (megavoltage) X-ray imaging is widely used in industry (e.g., aerospace, construction, material sciences) as well as in health care (radiation therapy). One of the fundamental problems with megavoltage imaging is poor contrast and spatial resolution in the detected images due to the dominance of Compton scattering at megavoltage X-ray energies. Therefore, although megavoltage X-rays can be used to image highly attenuating objects that cannot be imaged at kilovoltage energies, the former does not provide the high image quality that is associated with the latter. A high contrast and spatial resolution detector for high-energy X-ray fields called the kinestatic charge detector (KCD) is presented here. The KCD is a tri-electrode ion-chamber based on highly pressurized noble gas. The KCD operates in conjunction with a strip-collimated X-ray beam (for high scatter rejection) to scan across the imaging field. Its thick detector design and unique operating principle provides enhanced charge signal integration for high quality imaging (quantum efficiency ∼50%) despite the unfavorable implications of high-energy X-ray interactions on image quality. The proposed design for a large-field prototype KCD includes a cylindrical pressure chamber along with 576 signal-collecting electrodes capable of resolving at 2 mm -1 . The collecting electrodes are routed out of the chamber through the flat end-cap, thereby optimizing the mechanical strength of the chamber. This article highlights the simplified design of the chamber using minimal components for simple assembly. In addition, fundamental imaging measurements and estimates of ion recombination that were performed on a proof-of-principle test chamber are presented. The imaging performance of the prototype KCD was found to be an order-of-magnitude greater than commercial phosphor screen based flat-panel systems, demonstrating the potential for high-quality megavoltage imaging for a variety of industrial applications
Environmental test chamber for the support of learning and teaching in intelligent control
Taylor, C. James
2004-01-01
The paper describes the utility of a low cost, 1 m2 by 2 m forced ventilation, micro-climate test chamber, for the support of research and teaching in mechatronics. Initially developed for the evaluation of a new ventilation rate controller, the fully instrumented chamber now provides numerous learning opportunities and individual projects for both undergraduate and postgraduate research students.
Gradl, Paul; Barnett, Greg; Brandsmeier, Will; Greene, Sandy Elam; Protz, Chris
2016-01-01
NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM) otherwise commonly referred to as additive manufacturing. The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for the GRCop-84 copper-alloy commensurate with powder bed additive manufacturing, evaluate bimetallic deposition and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. As a direct spin off of this program, NASA is working with industry partners to further develop the printing process for the GRCop-84 material in addition to the C-18150 (CuCrZr) material. To advance the process further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic additively manufactured chambers. A 1.2k sized thrust-chamber was designed and developed to compare the printing process of the GRCop-84 and C-18150 SLM materials. A series of similar MCC liners also completed development with an Inconel 625 jacket bonded to the GRcop-84 liner evaluating direct metal deposition (DMD) laser and arc-based techniques. This paper describes the design, development, manufacturing and testing of these combustion chambers and associated lessons learned throughout the design and development process.
Scharfstein, Gregory; Cox, Russell
2012-01-01
A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.
Development and characterization of special ionization chambers for computed tomography beams
International Nuclear Information System (INIS)
Castro, Maysa Costa de
2016-01-01
The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology, because they allow the obtention of images with better resolution than through other techniques. Therefore, they are responsible for increasing the dose radiation of patients during the procedure. This fact led to a greater concern about the doses received by patients who undergo this type of examination. To perform the dosimetry in CT beams, the most widely used instrument is the pencil type ionization chamber, because this dosimeter has a uniform response to the incident radiation beam for all angles. The conventional ionization chamber, which is available on the market, has a sensitive volume length of 10 cm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study two ionization chambers with sensitive volume lengths of 10 cm and 30 cm, making use of low cost national materials, were developed at the Calibration Laboratory of Instruments (LCI-IPEN/CNEN). The characterization of these chambers was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chambers and a commercial chamber were tested in a clinical tomograph. The developed ionization chambers were analyzed in a complete way for their possible uses. (author)
Passive containment cooling system performance in the simplified boiling water reactor
International Nuclear Information System (INIS)
Shiralkar, B.S.; Gamble, R.E.; Yadigaroglu, G.
1997-01-01
The Simplified Boiling Water Reactor (SBWR) incorporates a passive system for decay heat removal from the containment in the event of a postulated Loss-of-Coolant Accident (LOCA). Decay heat is removed by condensation of the steam discharged from the reactor pressure vessel (RPV) in three condensers which comprise the Passive Containment Cooling System (PCCS). These condensers are designed to carry the heat load while transporting a mixture of steam and noncondensible gas (primarily nitrogen) from the drywell to the suppression chamber. This paper describes the expected LOCA response of the SBWR with respect to the PCCS performance, based on analysis and test results. The results confirm that the PCCS has excess capacity for decay heat removal and that overall system performance is very robust. 12 refs., 8 figs
International Nuclear Information System (INIS)
Inagaki, Yosuke
1977-01-01
Drift chamber is becoming an important detector in high energy physics as a precision and fast position detector because of its high spatial resolution and count-rate. The basic principle is that it utilizes the drift at constant speed of electrons ionized along the tracks of charged particles towards the anode wire in the nearly uniform electric field. The method of measuring drift time includes the analog and digital ones. This report describes about the construction of and the application of electric field to the drift chamber, mathematical analysis on the electric field and equipotential curve, derivation of spatial resolution and the factor for its determination, and selection of gas to be used. The performance test of the chamber was carried out using a small test chamber, the collimated β source of Sr-90, and 500 MeV/C electron beam from the 1.3 GeV electron synchrotron in the Institute of Nuclear Study, University of Tokyo. Most chambers to date adopted one dimensional read-out, but it is very advantageous if the two dimensional read-out is feasible with one chamber when the resolution in that direction is low. The typical methods of delay line and charge division for two dimensional read-out are described. The development of digital read-out system is underway, which can process the signal of a large scale drift chamber at high speed. (Wakatsuki, Y.)
Multiple chamber ionization detector
International Nuclear Information System (INIS)
Solomon, E.E.
1980-01-01
A multi-chambered ionisation detector enables the amount of radiation entering each chamber from a single radioactive, eg β, source to be varied by altering the proportion of the source protruding into each chamber. Electrodes define chambers and an extended radioactive source is movable to alter the source length in each chamber. Alternatively, the source is fixed relative to outer electrodes but the central electrode may be adjusted by an attached support altering the chamber dimensions and hence the length of source in each. Also disclosed are a centrally mounted source tiltable towards one or other chamber and a central electrode tiltable to alter chamber dimensions. (U.K.)
Mathupala, Saroj P.; Kiousis, Sam; Szerlip, Nicholas J.
2016-01-01
Background Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O2 concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system t...
Nuclear power generation cost methodology
International Nuclear Information System (INIS)
Delene, J.G.; Bowers, H.I.
1980-08-01
A simplified calculational procedure for the estimation of nuclear power generation cost is outlined. The report contains a discussion of the various components of power generation cost and basic equations for calculating that cost. An example calculation is given. The basis of the fixed-charge rate, the derivation of the levelized fuel cycle cost equation, and the heavy water charge rate are included as appendixes
Federal Laboratory Consortium — The Doriot Climatic Chambers are two, 60-feet long, 11-feet high, 15-feet wide chambers that are owned and operated by NSRDEC. The Doriot Climatic Chambers are among...
Acoustic streaming in simplified liquid rocket engines with transverse mode oscillations
Fischbach, Sean R.; Flandro, Gary A.; Majdalani, Joseph
2010-06-01
This study considers a simplified model of a liquid rocket engine in which uniform injection is imposed at the faceplate. The corresponding cylindrical chamber has a small length-to-diameter ratio with respect to solid and hybrid rockets. Given their low chamber aspect ratios, liquid thrust engines are known to experience severe tangential and radial oscillation modes more often than longitudinal ones. In order to model this behavior, tangential and radial waves are superimposed onto a basic mean-flow model that consists of a steady, uniform axial velocity throughout the chamber. Using perturbation tools, both potential and viscous flow equations are then linearized in the pressure wave amplitude and solved to the second order. The effects of the headwall Mach number are leveraged as well. While the potential flow analysis does not predict any acoustic streaming effects, the viscous solution carried out to the second order gives rise to steady secondary flow patterns near the headwall. These axisymmetric, steady contributions to the tangential and radial traveling waves are induced by the convective flow motion through interactions with inertial and viscous forces. We find that suppressing either the convective terms or viscosity at the headwall leads to spurious solutions that are free from streaming. In our problem, streaming is initiated at the headwall, within the boundary layer, and then extends throughout the chamber. We find that nonlinear streaming effects of tangential and radial waves act to alter the outer solution inside a cylinder with headwall injection. As a result of streaming, the radial wave velocities are intensified in one-half of the domain and reduced in the opposite half at any instant of time. Similarly, the tangential waves are either enhanced or weakened in two opposing sectors that are at 90° angle to the radial velocity counterparts. The second-order viscous solution that we obtain clearly displays both an oscillating and a steady flow
Kies, Alexander; von Bremen, Lüder; Schyska, Bruno; Chattopadhyay, Kabitri; Lorenz, Elke; Heinemann, Detlev
2016-04-01
The transition of the European power system from fossil generation towards renewable sources is driven by different reasons like decarbonisation and sustainability. Renewable power sources like wind and solar have, due to their weather dependency, fluctuating feed-in profiles, which make their system integration a difficult task. To overcome this issue, several solutions have been investigated in the past like the optimal mix of wind and PV [1], the extension of the transmission grid or storages [2]. In this work, the optimal distribution of wind turbines and solar modules in Europe is investigated. For this purpose, feed-in data with an hourly temporal resolution and a spatial resolution of 7 km covering Europe for the renewable sources wind, photovoltaics and hydro was used. Together with historical load data and a transmission model , a simplified pan-European power power system was simulated. Under cost assumptions of [3] the levelized cost of electricity (LCOE) for this simplified system consisting of generation, consumption, transmission and backup units is calculated. With respect to the LCOE, the optimal distribution of generation facilities in Europe is derived. It is shown, that by optimal placement of renewable generation facilities the LCOE can be reduced by more than 10% compared to a meta study scenario [4] and a self-sufficient scenario (every country produces on average as much from renewable sources as it consumes). This is mainly caused by a shift of generation facilities towards highly suitable locations, reduced backup and increased transmission need. The results of the optimization will be shown and implications for the extension of renewable shares in the European power mix will be discussed. The work is part of the RESTORE 2050 project (Wuppertal Institute, Next Energy, University of Oldenburg), that is financed by the Federal Ministry of Education and Research (BMBF, Fkz. 03SFF0439A). [1] Kies, A. et al.: Kies, Alexander, et al
International Nuclear Information System (INIS)
1977-01-01
An improved ionization chamber type X-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is placed next to the anode and is maintained at a voltage intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting towards the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure
Development of special ionization chambers for a quality control program in mammography
International Nuclear Information System (INIS)
Silva, Jonas Oliveira da
2013-01-01
Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)
International Nuclear Information System (INIS)
Yoshizumi, Maira Tiemi
2010-01-01
X radiation equipment may show fluctuations in the radiation beam intensity, as they are connected to the power net. These intensity variations can, in turn, modify the air kerma rate produced by this radiation beam. In a calibration laboratory, where radiation detectors (from clinics and hospital services) are calibrated, variations in the radiation beam intensity may cause an error in the absorbed dose determination. The monitor ionization chambers are used to verify the radiation beam intensity constancy, and to provide a correction for possible fluctuations. In this work, monitor ionization chambers for X radiation beams were designed, assembled and characterized. The developed ionization chambers have an innovative design, ring-shaped, with aluminium or graphite electrodes. These ring-shaped ionization chambers have the advantage of not interfering in the direct radiation beams. A double-volume ionization chamber with graphite electrodes was also developed. This ionization chamber is similar to the commercial monitor ionization chamber used in the Calibration Laboratory of the Instituto de Pesquisas Energeticas e Nucleares. All developed ionization chambers were tested in several standardized radiation beams and their performances were compared with those of commercial ionization chambers. The results show that two of the four ionization chambers developed showed performance comparable to that of the commercial ionization chambers tested. Besides presenting good results, the ionization chambers were designed and manufactured using low cost materials, which are easily found on the Brazilian market. (author)
International Nuclear Information System (INIS)
Shrestha, Ram M.; Abeygunawardana, A.M.A.K.
2007-01-01
Setting baseline emissions is one of the principal tasks involved in awarding credits for greenhouse gas emission (GHG) mitigation projects under the Clean Development Mechanism (CDM). An emission baseline has to be project-specific in order to be accurate. However, project-specific baseline calculations are subject to high transaction costs, which disadvantage small-scale projects. For this reason, the CDM-Executive Board (CDM-EB) has approved simplified baseline methodologies for selected small-scale CDM project categories. While the simplified methods help reduce the transaction cost, they may also result in inaccuracies in the estimation of emission reductions from CDM projects. The purpose of this paper is to present a rigorous economic scheduling method for calculating the GHG emission reduction in a hypothetical competitive electricity industry due to the operation of a renewable energy-based power plant under CDM and compare the GHG emission reduction derived from the rigorous method with that obtained from the use of a simplified (i.e., standardized) method approved by the CDM-EB. A key finding of the paper is that depending upon the level of power demand, prices of electricity and input fuels, the simplified method can lead to either significant overestimation or substantial underestimation of emission reduction due to the operation of renewable energy-based power projects in a competitive electricity industry
Numerical Simulation of Incremental Sheet Forming by Simplified Approach
Delamézière, A.; Yu, Y.; Robert, C.; Ayed, L. Ben; Nouari, M.; Batoz, J. L.
2011-01-01
The Incremental Sheet Forming (ISF) is a process, which can transform a flat metal sheet in a 3D complex part using a hemispherical tool. The final geometry of the product is obtained by the relative movement between this tool and the blank. The main advantage of that process is that the cost of the tool is very low compared to deep drawing with rigid tools. The main disadvantage is the very low velocity of the tool and thus the large amount of time to form the part. Classical contact algorithms give good agreement with experimental results, but are time consuming. A Simplified Approach for the contact management between the tool and the blank in ISF is presented here. The general principle of this approach is to imposed displacement of the nodes in contact with the tool at a given position. On a benchmark part, the CPU time of the present Simplified Approach is significantly reduced compared with a classical simulation performed with Abaqus implicit.
International piping benchmarks: use of the simplified code PACE 2. [LMFBR
Energy Technology Data Exchange (ETDEWEB)
Boyle, J T; Spence, J [University of Strathclyde (United Kingdom); Blundell, C [Risley Nuclear Power Development Establishment, Central Technical Services, Risley, Warrington (United Kingdom); ed.
1979-05-15
This report compares the results obtained using the code PACE 2 with the International Working Group on Fast Reactors (IWGFR) International Piping Benchmark solutions. PACE 2 is designed to analyse systems of pipework using a simplified method which is economical of computer time and hence inexpensive. This low cost is not achieved without some loss of accuracy in the solution, but for most parts of a system this inaccuracy is acceptable and those sections of particular importance may be reanalysed using more precise methods in order to produce a satisfactory analysis of the complete system at reasonable cost.
Simulated annealing algorithm for solving chambering student-case assignment problem
Ghazali, Saadiah; Abdul-Rahman, Syariza
2015-12-01
The problem related to project assignment problem is one of popular practical problem that appear nowadays. The challenge of solving the problem raise whenever the complexity related to preferences, the existence of real-world constraints and problem size increased. This study focuses on solving a chambering student-case assignment problem by using a simulated annealing algorithm where this problem is classified under project assignment problem. The project assignment problem is considered as hard combinatorial optimization problem and solving it using a metaheuristic approach is an advantage because it could return a good solution in a reasonable time. The problem of assigning chambering students to cases has never been addressed in the literature before. For the proposed problem, it is essential for law graduates to peruse in chambers before they are qualified to become legal counselor. Thus, assigning the chambering students to cases is a critically needed especially when involving many preferences. Hence, this study presents a preliminary study of the proposed project assignment problem. The objective of the study is to minimize the total completion time for all students in solving the given cases. This study employed a minimum cost greedy heuristic in order to construct a feasible initial solution. The search then is preceded with a simulated annealing algorithm for further improvement of solution quality. The analysis of the obtained result has shown that the proposed simulated annealing algorithm has greatly improved the solution constructed by the minimum cost greedy heuristic. Hence, this research has demonstrated the advantages of solving project assignment problem by using metaheuristic techniques.
Jiwani, Aliya; Himmelstein, David; Woolhandler, Steffie; Kahn, James G
2014-11-13
The United States' multiple-payer health care system requires substantial effort and costs for administration, with billing and insurance-related (BIR) activities comprising a large but incompletely characterized proportion. A number of studies have quantified BIR costs for specific health care sectors, using micro-costing techniques. However, variation in the types of payers, providers, and BIR activities across studies complicates estimation of system-wide costs. Using a consistent and comprehensive definition of BIR (including both public and private payers, all providers, and all types of BIR activities), we synthesized and updated available micro-costing evidence in order to estimate total and added BIR costs for the U.S. health care system in 2012. We reviewed BIR micro-costing studies across healthcare sectors. For physician practices, hospitals, and insurers, we estimated the % BIR using existing research and publicly reported data, re-calculated to a standard and comprehensive definition of BIR where necessary. We found no data on % BIR in other health services or supplies settings, so extrapolated from known sectors. We calculated total BIR costs in each sector as the product of 2012 U.S. national health expenditures and the percentage of revenue used for BIR. We estimated "added" BIR costs by comparing total BIR costs in each sector to those observed in existing, simplified financing systems (Canada's single payer system for providers, and U.S. Medicare for insurers). Due to uncertainty in inputs, we performed sensitivity analyses. BIR costs in the U.S. health care system totaled approximately $471 ($330 - $597) billion in 2012. This includes $70 ($54 - $76) billion in physician practices, $74 ($58 - $94) billion in hospitals, an estimated $94 ($47 - $141) billion in settings providing other health services and supplies, $198 ($154 - $233) billion in private insurers, and $35 ($17 - $52) billion in public insurers. Compared to simplified financing, $375
Combustion instability control in the model of combustion chamber
International Nuclear Information System (INIS)
Akhmadullin, A N; Ahmethanov, E N; Iovleva, O V; Mitrofanov, G A
2013-01-01
An experimental study of the influence of external periodic perturbations on the instability of the combustion chamber in a pulsating combustion. As an external periodic disturbances were used sound waves emitted by the electrodynamics. The purpose of the study was to determine the possibility of using the method of external periodic perturbation to control the combustion instability. The study was conducted on a specially created model of the combustion chamber with a swirl burner in the frequency range from 100 to 1400 Hz. The study found that the method of external periodic perturbations may be used to control combustion instability. Depending on the frequency of the external periodic perturbation is observed as an increase and decrease in the amplitude of the oscillations in the combustion chamber. These effects are due to the mechanisms of synchronous and asynchronous action. External periodic disturbance generated in the path feeding the gaseous fuel, showing the high efficiency of the method of management in terms of energy costs. Power required to initiate periodic disturbances (50 W) is significantly smaller than the thermal capacity of the combustion chamber (100 kW)
Influencing Factors and Simplified Model of Film Hole Irrigation
Directory of Open Access Journals (Sweden)
Yi-Bo Li
2017-07-01
Full Text Available Film hole irrigation is an advanced low-cost and high-efficiency irrigation method, which can improve water conservation and water use efficiency. Given its various advantages and potential applications, we conducted a laboratory study to investigate the effects of soil texture, bulk density, initial soil moisture, irrigation depth, opening ratio (ρ, film hole diameter (D, and spacing on cumulative infiltration using SWMS-2D. We then proposed a simplified model based on the Kostiakov model for infiltration estimation. Error analyses indicated SWMS-2D to be suitable for infiltration simulation of film hole irrigation. Additional SWMS-2D-based investigations indicated that, for a certain soil, initial soil moisture and irrigation depth had the weakest effects on cumulative infiltration, whereas ρ and D had the strongest effects on cumulative infiltration. A simplified model with ρ and D was further established, and its use was then expanded to different soils. Verification based on seven soil types indicated that the established simplified double-factor model effectively estimates cumulative infiltration for film hole irrigation, with a small mean average error of 0.141–2.299 mm, a root mean square error of 0.177–2.722 mm, a percent bias of −2.131–1.479%, and a large Nash–Sutcliffe coefficient that is close to 1.0.
Planetary Simulation Chambers bring Mars to laboratory studies
Energy Technology Data Exchange (ETDEWEB)
Mateo-Marti, E.
2016-07-01
Although space missions provide fundamental and unique knowledge for planetary exploration, they are always costly and extremely time-consuming. Due to the obvious technical and economical limitations of in-situ planetary exploration, laboratory simulations are among the most feasible research options for making advances in planetary exploration. Therefore, laboratory simulations of planetary environments are a necessary and complementary option to expensive space missions. Simulation chambers are economical, more versatile, and allow for a higher number of experiments than space missions. Laboratory-based facilities are able to mimic the conditions found in the atmospheres and on the surfaces of a majority of planetary objects. Number of relevant applications in Mars planetary exploration will be described in order to provide an understanding about the potential and flexibility of planetary simulation chambers systems: mainly, stability and presence of certain minerals on Mars surface; and microorganisms potential habitability under planetary environmental conditions would be studied. Therefore, simulation chambers will be a promising tools and necessary platform to design future planetary space mission and to validate in-situ measurements from orbital or rover observations. (Author)
Investigation on the optimal simplified model of BIW structure using FEM
Directory of Open Access Journals (Sweden)
Mohammad Hassan Shojaeefard
Full Text Available Abstract At conceptual phases of designing a vehicle, engineers need simplified models to examine the structural and functional characteristics and apply custom modifications for achieving the best vehicle design. Using detailed finite-element (FE model of the vehicle at early steps can be very conducive; however, the drawbacks of being excessively time-consuming and expensive are encountered. This leads engineers to utilize trade-off simplified models of body-in-white (BIW, composed of only the most decisive structural elements that do not employ extensive prior knowledge of the vehicle dimensions and constitutive materials. However, the extent and type of simplification remain ambiguous. In fact during the procedure of simplification, one will be in the quandary over which kind of approach and what body elements should be regarded for simplification to optimize costs and time, while providing acceptable accuracy. Although different approaches for optimization of timeframe and achieving optimal designs of the BIW are proposed in the literature, a comparison between different simplification methods and accordingly introducing the best models, which is the main focus of this research, have not yet been done. In this paper, an industrial sedan vehicle has been simplified through four different simplified FE models, each of which examines the validity of the extent of simplification from different points of views. Bending and torsional stiffness are obtained for all models considering boundary conditions similar to experimental tests. The acquired values are then compared to that of target values from experimental tests for validation of the FE-modeling. Finally, the results are examined and taking efficacy and accuracy into account, the best trade-off simplified model is presented.
Federal Regulations: Efforts to Estimate Total Costs and Benefits of Rules
2004-04-07
the Chamber of Commerce , academicians, the media, and others, and is sometimes cited with a high degree of certainty ." For example, some articles...House of Representatives, Feb . 25,2004; and testimony of William P . Kovacs, Vice President, U .S. Chamber of Commerce , before the Subcommittee on Energy...estimated the annual cost to employers of the Family and Medical Leave Act at $825 million, but that the Chamber of Commerce estimated the cost at between $3
Simplified Perovskite Solar Cell with 4.1% Efficiency Employing Inorganic CsPbBr3 as Light Absorber.
Duan, Jialong; Zhao, Yuanyuan; He, Benlin; Tang, Qunwei
2018-04-17
Perovskite solar cells with cost-effectiveness, high power conversion efficiency, and improved stability are promising solutions to the energy crisis and environmental pollution. However, a wide-bandgap inorganic-semiconductor electron-transporting layer such as TiO 2 can harvest ultraviolet light to photodegrade perovskite halides, and the high cost of a state-of-the-art hole-transporting layer is an economic burden for commercialization. Here, the building of a simplified cesium lead bromide (CsPbBr 3 ) perovskite solar cell with fluorine-doped tin oxide (FTO)/CsPbBr 3 /carbon architecture by a multistep solution-processed deposition technology is demonstrated, achieving an efficiency as high as 4.1% and improved stability upon interfacial modification by graphene quantum dots and CsPbBrI 2 quantum dots. This work provides new opportunities of building next-generation solar cells with significantly simplified processes and reduced production costs. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Income Tax Returns: Reducing Compliance Costs for Personal Income Taxpayers in Slovenia
Directory of Open Access Journals (Sweden)
Maja Klun
2009-06-01
Full Text Available Simplifying procedures and improving legislation generally lead to a reduction in the compliance costs. The introduction of pre-filled tax returns clearly simplifies the tax compliance procedure. Before the introduction of pre-filled tax returns for personal income taxpayers in Slovenia, tax legislation was also modified. This paper presents the results of research into the compliance costs for personal income taxpayers before and after the simplification of the compliance procedure in Slovenia, irrespective of tax legislation itself not being simplified. The results indicate that pre-filled tax returns reduce compliance costs for personal income taxpayers by around 73%. Nevertheless, this is only a tentative estimate, since several assumptions are taken into account.
Precision Muon Tracking at Future Hadron Colliders with sMDT Chambers
Kortner, Oliver; Müller, Felix; Nowak, Sebastian; Richter, Robert
2016-01-01
Small-diameter muon drift tube (sMDT) chambers are a cost-effective technology for high-precision muon tracking. The rate capability of the sMDT chambers has been extensively tested at the Gamma Irradiation Facility at CERN in view of expected rates at future high-energy hadron colliders. Results show that it fulfills the requirements over most of the acceptance of muon detectors. The optimization of the read-out electronics to further increase the rate capability of the detectors is discussed. Chambers of this type are under construction for upgrades of the muon spectrometer of the ATLAS detector at high LHC luminosities. Design and construction procedures have been optimized for mass production while providing a precision of better than 10 micrometers in the sense wire positions and the mechanical stability required to cover large areas.
International Nuclear Information System (INIS)
Mallory, J.; Turlej, Z.
1981-01-01
Dual ionization chambers are provided for use with an electronic smoke detector. The chambers are separated by electrically-conductive partition. A single radiation source extends through the partition into both chambers, ionizing the air in each. The mid-point current of the device may be balanced by adjusting the position of the source
Performance of microstrip gas chambers in BNL-E885: a search for LAMBDA LAMBDA-hypernuclei
Landry, M; Davis, C A; Faszer, W; Gan, L; Lee, L; Page, S A; Ramsay, W D; Salomon, M; Oers, W T H
1999-01-01
The performance of MicroStrip Gas Chambers (MSGC) in BNL Experiment 885, a search for LAMBDA LAMBDA-hypernuclei, is detailed. Chambers with an active area of 80x50 mm sup 2 were instrumented and operated as a vertex detector in the experiment. Furthermore, two distinct types of microstrip prints were utilized in these chambers. Prints manufactured with Integrated Circuit (IC) photolithographic technology have fine tolerances and thin minimum trace widths, but can suffer from a high rate of defects per print and are more costly. Prints constructed with Printed Circuit (PC) photolithographic technology have coarser tolerances but relatively few defects per print, and are extremely cost-effective. Results of bench and beam tests of both IC and PC based MSGCs are presented and their performance in BNL-E885 is discussed. E885 marks the first use of PC based MSGCs in an experiment.
LENUS (Irish Health Repository)
Zhou, Ping
2011-08-03
Abstract Background To simplify the methodology for the isolation of Campylobacter spp. from retail broiler meat, we evaluated 108 samples (breasts and thighs) using an unpaired sample design. The enrichment broths were incubated under aerobic conditions (subsamples A) and for comparison under microaerobic conditions (subsamples M) as recommended by current reference protocols. Sensors were used to measure the dissolved oxygen (DO) in the broth and the percentage of oxygen (O2) in the head space of the bags used for enrichment. Campylobacter isolates were identified with multiplex PCR assays and typed using pulsed-field gel electrophoresis (PFGE). Ribosomal intergenic spacer analyses (RISA) and denaturing gradient gel electrophoresis (DGGE) were used to study the bacterial communities of subsamples M and A after 48 h enrichment. Results The number of Campylobacter positive subsamples were similar for A and M when all samples were combined (P = 0.81) and when samples were analyzed by product (breast: P = 0.75; thigh: P = 1.00). Oxygen sensors showed that DO values in the broth were around 6 ppm and O2 values in the head space were 14-16% throughout incubation. PFGE demonstrated high genomic similarity of isolates in the majority of the samples in which isolates were obtained from subsamples A and M. RISA and DGGE results showed a large variability in the bacterial populations that could be attributed to sample-to-sample variations and not enrichment conditions (aerobic or microaerobic). These data also suggested that current sampling protocols are not optimized to determine the true number of Campylobacter positive samples in retail boiler meat. Conclusions Decreased DO in enrichment broths is naturally achieved. This simplified, cost-effective enrichment protocol with aerobic incubation could be incorporated into reference methods for the isolation of Campylobacter spp. from retail broiler meat.
Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
1967-01-01
Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Rapid Manufacture of Combustion Chambers Using Ductile, High Strength MMCs (1000-803), Phase I
National Aeronautics and Space Administration — Triton Systems, Inc. (Triton) proposes to develop a cost-effective manufacturing approach to fabricate combustion chambers for a rocket technology demonstrator...
International Nuclear Information System (INIS)
Boag, J.W.
1987-01-01
Although a variety of solid-state and chemical methods for measuring radiation dose have been developed in recent decades and calorimetry can now provide an absolute standard of reference, ionization dosimetry retains its position as the most widely used, most convenient, and, in most situations, most accurate method of measuring either exposure or absorbed dose. The ionization chamber itself is the central element in this system of dosimetry. In this chapter the principles governing the construction and operation of ionization chambers of various types are examined. Since the ionization chambers now in general use are nearly all of commercial manufacture, the emphasis is on operating characteristics and interpretation of measurements rather than on details of construction, although some knowledge of the latter is often required when applying necessary corrections to the measured quantities. Examples are given of the construction of typical chambers designed for particular purposes, and the methods of calibrating them are discussed
Simplified model of a PWR primary circuit
International Nuclear Information System (INIS)
Souza, A.L.; Faya, A.J.G.
1988-07-01
The computer program RENUR was developed to perform a very simplified simulation of a typical PWR primary circuit. The program has mathematical models for the thermal-hydraulics of the reactor core and the pressurizer, the rest of the circuit being treated as a single volume. Heat conduction in the fuel rod is analyzed by a nodal model. Average and hot channels are treated so that bulk response of the core and DNBR can be evaluated. A homogenenous model is employed in the pressurizer. Results are presented for a steady-state situation as well as for a loss of load transient. Agreement with the results of more elaborate computer codes is good with substantial reduction in computer costs. (author) [pt
International Nuclear Information System (INIS)
McIntyre, P.M.; Barasch, E.F.; Bowcock, T.J.V.; Demroff, H.P.; Elliott, S.M.; Howe, M.R.; Lee, B.; Mazumdar, T.K.; Pang, Y.; Smith, D.D.; Wahl, J.; Wu, Y.; Yue, W.K.; Gaedke, R.M.; Vanstraelen, G.
1992-01-01
The gas microstrip chamber has been developed from concept to experimental system during the past three years. A pattern of anode and grid lines are microfabricated onto a dielectric substrate and configured as a high-resolution MWPC. Four recent developments are described: Suitable plastic substrates and lithography techniques for large-area chambers; non-planar silicon-based chambers for 20 μm resolution; integrated on-board synchronous front-end electronics and data buffering; and a porous silicon active cathode for enhanced efficiency and time response. The microstrip chamber appears to be a promising technology for applications in microvertex, tracking spectrometer, muon spectrometer, and transition radiation detection. (orig.)
Production and Costs of the Chambers Delimbinator in First Thinning of Pine Plantations
Scott T. Mooney; Kevin D. Boston; W. Dale Greene
2000-01-01
Production and quality measures were collected and analyzed for a new chain-flail delimbing machine, Chambers Delimbinator, on two operations in central and southwestern Georgia. The first operation, Logger A, used two skidders and one loader while the second operation, Logger B, used two skidder and two loaders. Lobber B with the lower cycle time and larger piece...
International Nuclear Information System (INIS)
Uman, M.F.; Winnard, J.R.; Winters, H.F.
1978-01-01
The ion source is comprised of two discharge chambers one of which is provided with a filament and an aperture leading into the other chamber which in turn has an extraction orifice. A low voltage arc discharge is operated in an inert gas atmosphere in the filament chamber while an arc of higher voltage is operated in the second ionization chamber which contains a vapor which will give the desired dopant ion species. The entire source is immersed in an axial magnetic field parallel to a line connecting the filament, the aperture between the two chambers and the extraction orifice. (author)
Westerhout, J.; Wortelboer, H.; Verhoeckx, K.
2015-01-01
The Ussing chamber system is named after the Danish zoologist Hans Ussing, who invented the device in the 1950s to measure the short-circuit current as an indicator of net ion transport taking place across frog skin (Ussing and Zerahn, Acta Physiol Scand 23:110-127, 1951). Ussing chambers are
DELPHI Barrel Muon Chamber Module
1989-01-01
The module was used as part of the muon identification system on the barrel of the DELPHI detector at LEP, and was in active use from 1989 to 2000. The module consists of 7 individual muons chambers arranged in 2 layers. Chambers in the upper layer are staggered by half a chamber width with respect to the lower layer. Each individual chamber is a drift chamber consisting of an anode wire, 47 microns in diameter, and a wrapped copper delay line. Each chamber provided 3 signal for each muon passing through the chamber, from which a 3D space-point could be reconstructed.
Electromagnetic analysis of the plasma chamber of an ECR-based charge breeder
Galatà, A.; Patti, G.; Celona, L.; Mascali, D.; Neri, L.; Torrisi, G.
2016-02-01
The optimization of the efficiency of an ECR-based charge breeder is a twofold task: efforts must be paid to maximize the capture of the injected 1+ ions by the confined plasma and to produce high charge states to allow post-acceleration at high energies. Both tasks must be faced by studying in detail the electrons heating dynamics, influenced by the microwave-to-plasma coupling mechanism. Numerical simulations are a powerful tools for obtaining quantitative information about the wave-to-plasma interaction process: this paper presents a numerical study of the microwaves propagation and absorption inside the plasma chamber of the PHOENIX charge breeder, which the selective production of exotic species project, under construction at Legnaro National Laboratories, will adopt as charge breeder. Calculations were carried out with a commercial 3D FEM solver: first, all the resonant frequencies were determined by considering a simplified plasma chamber; then, the realistic geometry was taken into account, including a cold plasma model of increasing complexity. The results gave important information about the power absorption and losses and will allow the improvement of the plasma model to be used in a refined step of calculation reproducing the breeding process itself.
Electromagnetic analysis of the plasma chamber of an ECR-based charge breeder
International Nuclear Information System (INIS)
Galatà, A.; Patti, G.; Celona, L.; Mascali, D.; Neri, L.; Torrisi, G.
2016-01-01
The optimization of the efficiency of an ECR-based charge breeder is a twofold task: efforts must be paid to maximize the capture of the injected 1+ ions by the confined plasma and to produce high charge states to allow post-acceleration at high energies. Both tasks must be faced by studying in detail the electrons heating dynamics, influenced by the microwave-to-plasma coupling mechanism. Numerical simulations are a powerful tools for obtaining quantitative information about the wave-to-plasma interaction process: this paper presents a numerical study of the microwaves propagation and absorption inside the plasma chamber of the PHOENIX charge breeder, which the selective production of exotic species project, under construction at Legnaro National Laboratories, will adopt as charge breeder. Calculations were carried out with a commercial 3D FEM solver: first, all the resonant frequencies were determined by considering a simplified plasma chamber; then, the realistic geometry was taken into account, including a cold plasma model of increasing complexity. The results gave important information about the power absorption and losses and will allow the improvement of the plasma model to be used in a refined step of calculation reproducing the breeding process itself
DEFF Research Database (Denmark)
Fan, Wei; Kyösti, Pekka; Rumney, Moray
2018-01-01
antenna selection scheme is proposed. This setup is suitable for evaluation of beam-steerable devices, including both base station (BS) and user equipment (UE) devices. The requirements for the test system design are analyzed, including the measurement range, number of OTA antennas, number of active OTA...... conditions. In this article, radiated testing methods are reviewed, with a focus on their principle and applicability for beam steerable mmWave devices. To explore the spatial sparsity of mmWave channel profiles, a cost-effective simplified 3D sectored multi-probe anechoic chamber (MPAC) system with an OTA......With the severe spectrum congestion of sub-6GHz cellular systems, large-scale antenna systems in the millimeter-wave (mmWave) bands can potentially meet the high data rate envisioned for fifth generation (5G) communications. Performance evaluation of antenna systems is an essential step...
Reis Batista, Isabel; Garcia, Ainhoa Blanco; Dalen, Van Pim; Kamermans, Pauline; Verdegem, Marc; Smaal, Aad C.
2015-01-01
Land-based bivalve aquaculture depends on large-scale cultures of live microalgae for food. The intensity of large-scale microalgal production is important for cost-effectiveness. Using Walne’s medium as the control, simplified media containing nitrogen, phosphorus, silica, iron, manganese and
Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux
Energy Technology Data Exchange (ETDEWEB)
Davis, Morgan P.; Groh, Tyler A.; Parkin, Timothy B.; Williams, Ryan J.; Isenhart, Thomas M.; Hofmockel, Kirsten S.
2018-01-01
Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.
International Nuclear Information System (INIS)
Houston, J.M.
1977-01-01
An improved ionization chamber type x-ray detector comprises a heavy gas at high pressure disposed between an anode and a cathode. An open grid structure is disposed adjacent the anode and is maintained at a voltsge intermediate between the cathode and anode potentials. The electric field which is produced by positive ions drifting toward the cathode is thus shielded from the anode. Current measuring circuits connected to the anode are, therefore, responsive only to electron current flow within the chamber and the recovery time of the chamber is shortened. The grid structure also serves to shield the anode from electrical currents which might otherwise be induced by mechanical vibrations in the ionization chamber structure
Study of an avalanche-mode resistive plate chamber
International Nuclear Information System (INIS)
Ying, J.; Ban, Y.; Liu, H.T.; Zhu, Z.M.; Zhu, Z.Y.; Chen, T.; Ma, J.G.; Ye, Y.L.
2000-01-01
Resistive plate chambers (RPCs) are widely used to detect high-energy charged particles, especially muons, due to the high gain, moderate time and spatial resolution, simple design and low cost of these detectors. While the simple streamer mode is adequate for cosmic-ray and low-rate accelerator experiments, the avalanche mode is required for high-rate experiments such as CMS at LHC. In this paper construction of a medium-sized double-gap RPC made of Chinese materials is reported. The experimental set-up of cosmic-ray and muon beam tests are introduced. The avalanche mode was clearly observed. Good efficiency and time resolution were obtained from the beam test at CERN under normal irradiation conditions. At very high radiation background the chamber efficiency decreases, indicating the necessity to change the resistivity value of the Chinese bakelites. (author)
Directory of Open Access Journals (Sweden)
Mohiuddin Khan Shourav
2016-07-01
Full Text Available Field curvature and other aberrations are encountered inevitably when designing a compact fluorescence imaging system with a simple lens. Although multiple lens elements can be used to correct most such aberrations, doing so increases system cost and complexity. Herein, we propose a wide field-of-view (FOV fluorescence imaging method with an unconventional optical-quality curved sample chamber that corrects the field curvature caused by a simple lens. Our optics simulations and proof-of-concept experiments demonstrate that a curved substrate with lens-dependent curvature can reduce greatly the distortion in an image taken with a conventional planar detector. Following the validation study, we designed a curved sample chamber that can contain a known amount of sample volume and fabricated it at reasonable cost using plastic injection molding. At a magnification factor of approximately 0.6, the curved chamber provides a clear view of approximately 119 mm2, which is approximately two times larger than the aberration-free area of a planar chamber. Remarkably, a fluorescence image of microbeads in the curved chamber exhibits almost uniform intensity over the entire field even with a simple lens imaging system, whereas the distorted boundary region has much lower brightness than the central area in the planar chamber. The absolute count of white blood cells stained with a fluorescence dye was in good agreement with that obtained by a commercially available conventional microscopy system. Hence, a wide FOV imaging system with the proposed curved sample chamber would enable us to acquire an undistorted image of a large sample volume without requiring a time-consuming scanning process in point-of-care diagnostic applications.
Awate, Bhushan; Steidl, Rebecca J.; Hamlischer, Thilo; Reguera, Gemma
2017-07-01
Unwanted metabolites produced during fermentations reduce titers and productivity and increase the cost of downstream purification of the targeted product. As a result, the economic feasibility of otherwise attractive fermentations is low. Using ethanol fermentation by the consolidated bioprocessing cellulolytic bacterium Cellulomonas uda, we demonstrate the effectiveness of anodic electro-fermentations at maximizing titers and productivity in a single-chamber microbial electrolysis cell (SCMEC) without the need for metabolic engineering of the fermentative microbe. The performance of the SCMEC platform relied on the genetic improvements of anode biofilms of the exoelectrogen Geobacter sulfurreducens that prevented the oxidation of cathodic hydrogen and improved lactate oxidation. Furthermore, a hybrid bioanode was designed that maximized the removal of organic acids in the fermentation broth. The targeted approach increased cellobiose consumption rates and ethanol titers, yields, and productivity three-fold or more, prevented pH imbalances and reduced batch-to-batch variability. In addition, the sugar substrate was fully consumed and ethanol was enriched in the broth during the electro-fermentation, simplifying its downstream purification. Such improvements and the possibility of scaling up SCMEC configurations highlight the potential of anodic electro-fermentations to stimulate fermentative bacteria beyond their natural capacity and to levels required for industrial implementation.
Information security governance simplified from the boardroom to the keyboard
Fitzgerald, Todd
2011-01-01
Security practitioners must be able to build cost-effective security programs while also complying with government regulations. Information Security Governance Simplified: From the Boardroom to the Keyboard lays out these regulations in simple terms and explains how to use control frameworks to build an air-tight information security (IS) program and governance structure. Defining the leadership skills required by IS officers, the book examines the pros and cons of different reporting structures and highlights the various control frameworks available. It details the functions of the security d
[Simplified laparoscopic gastric bypass. Initial experience].
Hernández-Miguelena, Luis; Maldonado-Vázquez, Angélica; Cortes-Romano, Pablo; Ríos-Cruz, Daniel; Marín-Domínguez, Raúl; Castillo-González, Armando
2014-01-01
Obesity surgery includes various gastrointestinal procedures. Roux-en-Y gastric bypass is the prototype of mixed procedures being the most practiced worldwide. A similar and novel technique has been adopted by Dr. Almino Cardoso Ramos and Dr. Manoel Galvao called "simplified bypass," which has been accepted due to the greater ease and very similar results to the conventional technique. The aim of this study is to describe the results of the simplified gastric bypass for treatment of morbid obesity in our institution. We performed a descriptive, retrospective study of all patients undergoing simplified gastric bypass from January 2008 to July 2012 in the obesity clinic of a private hospital in Mexico City. A total of 90 patients diagnosed with morbid obesity underwent simplified gastric bypass. Complications occurred in 10% of patients; these were more frequent bleeding and internal hernia. Mortality in the study period was 0%. The average weight loss at 12 months was 72.7%. Simplified gastric bypass surgery is safe with good mid-term results and a loss of adequate weight in 71% of cases.
Conceptual design of simplified PWR
International Nuclear Information System (INIS)
Tabata, Hiroaki
1996-01-01
The limited availability for location of nuclear power plant in Japan makes plants with higher power ratings more desirable. Having no intention of constructing medium-sized plants as a next generation standard plant, Japanese utilities are interested in applying passive technologies to large ones. So, Japanese utilities have studied large passive plants based on AP600 and SBWR as alternative future LWRs. In a joint effort to develop a new generation nuclear power plant which is more friendly to operator and maintenance personnel and is economically competitive with alternative sources of power generation, JAPC and Japanese Utilities started the study to modify AP600 and SBWR, in order to accommodate the Japanese requirements. During a six year program up to 1994, basic concepts for 1000 MWe class Simplified PWR (SPWR) and Simplified BWR (SBWR) were developed, though there still remain several areas to be improved. These studies have now stepped into the phase of reducing construction cost and searching for maximum power rating that can be attained by reasonably practical technology. These results also suggest that it is hopeful to develop a large 3-loop passive plant (∼1200 MWe). Since Korea mainly deals with PWR, this paper summarizes SPWR study. The SPWR is jointly studied by JAPC, Japanese PWR Utilities, EdF, WH and Mitsubishi Heavy Industry. Using the AP-600 reference design as a basis, we enlarged the plant size to 3-loops and added engineering features to conform with Japanese practice and Utilities' preference. The SPWR program definitively confirmed the feasibility of a passive plant with an NSSS rating about 1000 MWe and 3 loops. (J.P.N.)
Energy Technology Data Exchange (ETDEWEB)
Ravichandran, K.; Philominathan, P. [PG and Research Department of Physics, AVVM, Sri Pushpam College, Poondi, Thanjavur District, Tamil Nadu (India)
2008-11-15
Good quality CdS films were fabricated by employing a simplified spray pyrolysis technique using perfume atomizer. CdS films have been deposited from aqueous solutions of sulphur and cadmium, keeping the molar concentrations of S:Cd = 0.01:0.01, 0.02:0.02, 0.04:0.04 and 0.06:0.06 in the starting solutions. The structural studies reveal that the S:Cd concentration has a strong influence on the microstructural characteristics of the sprayed CdS films. It was found that there is a transition in the preferred orientation from (0 0 2) plane to (1 0 1) plane when S:Cd molar concentration increases. The SEM images depict that the films are uniform and homogeneous. All the films have high optical transmittance (>80%) in the visible range. The optical band gap values are found to be in the range of 2.46-2.52 eV. CdS films fabricated by this simple and economic spray technique without using any carrier gas are found to be good in structural and optical properties which are desirable for photovoltaic applications. Hence, this simplified version of spray technique can be considered as an economic alternative to conventional spray pyrolysis (using carrier gas), for the mass production of low-cost, large area CdS coatings for solar cell applications. (author)
National Aeronautics and Space Administration — Silicided niobium alloy (C103) combustion chambers have been used extensively in both NASA and DoD liquid rocket propulsion systems. Niobium alloys offer a good...
International Nuclear Information System (INIS)
Goto, Shoji; Ohmori, Shuichi; Mori, Michitsugu
2006-01-01
The total space and weight of the feedwater heaters in a nuclear power plant (NPP) can be reduced by replacing low-pressure feedwater heaters with high-efficiency steam injectors (SIs). The SI works as a direct heat exchanger between feedwater from condensers and steam extracted from turbines. It can attain pressures higher than the supplied steam pressure. The maintenance cost is lower than that of the current feedwater heater because of its simplified system without movable parts. In this paper, we explain the observed mechanisms of the SI experimentally and the analysis of the computational fluid dynamics (CFD). We then describe mainly the analysis of the heat balance and plant efficiency of the innovative-simplified NPP, which adapted to the boiling water reactor (BWR) with the high-efficiency SI. The plant efficiencies of this innovative-simplified BWR with SI are compared with those of a 1 100 MWe-class BWR. The SI model is adopted in the heat balance simulator as a simplified model. The results show that the plant efficiencies of the innovate-simplified BWR with SI are almost equal to those of the original BWR. They show that the plant efficiency would be slightly higher if the low-pressure steam, which is extracted from the low-pressure turbine, is used because the first-stage of the SI uses very low pressure. (author)
International Nuclear Information System (INIS)
Perini, Ana P.; Neves, Lucio P.; Caldas, Linda V.E.
2014-01-01
Diagnostic x-rays are the greatest source of exposition to ionizing radiation of the population worldwide. In order to obtain accurate and lower-cost dosimeters for quality control assurance of medical x-ray facilities, a special ionization chamber was designed at the Calibration Laboratory of the IPEN, for dosimetry in diagnostic radiology beams. For the chamber characterization some tests were undertaken. Monte Carlo simulations were proposed to evaluate the distribution of the deposited energy in the sensitive volume of the ionization chamber and the collecting electrode effect on the chamber response. According to the obtained results, this special ionization chamber presents potential use for dosimetry of conventional diagnostic radiology beams. - Highlights: • An ionization chamber with a novel design was characterized for x-ray beam dosimetry. • This ionization chamber was evaluated in diagnostic radiology qualities. • The characterization tests results were within the recommended limits. • Monte Carlo simulations were employed to evaluate the design of the dosimeter. • The developed prototype is a good alternative for calibration laboratories and clinics
Gui, Xulong; Luo, Xiaobing; Wang, Xiaoping; Liu, Sheng
2015-12-01
Micro-electrical-mechanical system (MEMS) has become important for many industries such as automotive, home appliance, portable electronics, especially with the emergence of Internet of Things. Volume testing with temperature compensation has been essential in order to provide MEMS based sensors with repeatability, consistency, reliability, and durability, but low cost. Particularly, in the temperature calibration test, temperature uniformity of thermal cycling based calibration chamber becomes more important for obtaining precision sensors, as each sensor is different before the calibration. When sensor samples are loaded into the chamber, we usually open the door of the chamber, then place fixtures into chamber and mount the samples on the fixtures. These operations may affect temperature uniformity in the chamber. In order to study the influencing factors of sample-loading on the temperature uniformity in the chamber during calibration testing, numerical simulation work was conducted first. Temperature field and flow field were simulated in empty chamber, chamber with open door, chamber with samples, and chamber with fixtures, respectively. By simulation, it was found that opening chamber door, sample size and number of fixture layers all have effects on flow field and temperature field. By experimental validation, it was found that the measured temperature value was consistent with the simulated temperature value.
3.6 simplified methods for design
International Nuclear Information System (INIS)
Nickell, R.E.; Yahr, G.T.
1981-01-01
Simplified design analysis methods for elevated temperature construction are classified and reviewed. Because the major impetus for developing elevated temperature design methodology during the past ten years has been the LMFBR program, considerable emphasis is placed upon results from this source. The operating characteristics of the LMFBR are such that cycles of severe transient thermal stresses can be interspersed with normal elevated temperature operational periods of significant duration, leading to a combination of plastic and creep deformation. The various simplified methods are organized into two general categories, depending upon whether it is the material, or constitutive, model that is reduced, or the geometric modeling that is simplified. Because the elastic representation of material behavior is so prevalent, an entire section is devoted to elastic analysis methods. Finally, the validation of the simplified procedures is discussed
Economical analysis based on a simplified model of micro distillery
International Nuclear Information System (INIS)
Bristoti, A.; Adams, R.
1987-01-01
The investment costs of the hydrate alcohol distillery as well as the energy balance of its production made inviable its diffusion on a small scale. The present economical analysis is based on a simplified model of micro distillery where the reduction on investment costs in based on technical data based on the possibility of the utilization of an hydrate alcohol with a higher water constant than the usual, i. e. around 85 0 GL. The engineering project of this plant eliminates all pumps, all the liquids (water, sugar cane, syrup and wine) are fed by gravity. The bagasse is considered a noble by-product and it is utilized in poultry industry as a substitute of wood dust. All the heat needs of the micro distillery are supplied by wood. (author)
Electromagnetic reverberation chambers
Besnier, Philippe
2013-01-01
Dedicated to a complete presentation on all aspects of reverberation chambers, this book provides the physical principles behind these test systems in a very progressive manner. The detailed panorama of parameters governing the operation of electromagnetic reverberation chambers details various applications such as radiated immunity, emissivity, and shielding efficiency experiments.In addition, the reader is provided with the elements of electromagnetic theory and statistics required to take full advantage of the basic operational rules of reverberation chambers, including calibration proc
Dorsal skinfold chamber models in mice
Directory of Open Access Journals (Sweden)
Schreiter, Jeannine
2017-07-01
Full Text Available Background/purpose: The use of dorsal skinfold chamber models has substantially improved the understanding of micro-vascularisation in pathophysiology over the last eight decades. It allows pathophysiological studies of vascularisation over a continuous period of time. The dorsal skinfold chamber is an attractive technique for monitoring the vascularisation of autologous or allogenic transplants, wound healing, tumorigenesis and compatibility of biomaterial implants. To further reduce the animals’ discomfort while carrying the dorsal skinfold chamber, we developed a smaller chamber (the Leipzig Dorsal Skinfold Chamber and summarized the commercial available chamber models. In addition we compared our model to the common chamber. Methods: The Leipzig Dorsal Skinfold Chamber was applied to female mice with a mean weight of 22 g. Angiogenesis within the dorsal skinfold chamber was evaluated after injection of fluorescein isothiocyanate dextran with an Axio Scope microscope. The mean vessel density within the dorsal skinfold chamber was assessed over a period of 21 days at five different time points. The gained data were compared to previous results using a bigger and heavier dorsal skinfold model in mice. A PubMed and a patent search were performed and all papers related to “dorsal skinfold chamber” from 1 of January 2006 to 31 of December 2015 were evaluated regarding the dorsal skinfold chamber models and their technical improvements. The main models are described and compared to our titanium Leipzig Dorsal Skinfold Chamber model.Results: The Leipzig Dorsal Skinfold Chamber fulfils all requirements of continuous models known from previous chamber models while reducing irritation to the mice. Five different chamber models have been identified showing substantial regional diversity. The newly elaborated titanium dorsal skinfold chamber may replace the pre-existing titanium chamber model used in Germany so far, as it is smaller and lighter
A combination drift chamber/pad chamber for very high readout rates
International Nuclear Information System (INIS)
Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W.; Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J.; Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P.; Arenton, M.; Conetti, S.; Cox, B.; Dukes, E.; Golovatyuk, V.; Hanlet, P.; McManus, A.; Nelson, K.; Recagni, M.; Segal, J.; Sun, J.; Ballagh, C.; Bingham, H.; Kaeding, T.; Lys, J.; Misawa, S.; Blankman, A.; Borodin, S.; Kononenko, W.; Newcomer, M.; Selove, W.; Trojak, T.; VanBerg, R.; Zhang, S.N.; Block, M.; Corti, G.; LeCompte, T.; Rosen, J.; Yao, T.; Boden, A.; Cline, D.; Ramachandran, S.; Rhoades, J.; Tokar, S.; Budagov, J.; Tsyganov, E.; Cao, Z.L.; He, M.; Wang, C.; Wei, C.; Zhang, N.; Chen, T.Y.; Yao, N.; Clark, K.; Jenkins, M.; Cooper, M.; Creti, P.; Gorini, E.; Grancagnolo, F.; Panareo, M.; Fortney, L.; Kowald, W.; Haire, M.; Judd, D.; Turnbull, L.; Wagoner, D.; Lau, K.; Mo, G.; Trischuk, J.
1991-11-01
Six medium-sized (∼1 x 2 m 2 ) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers
A combination drift chamber/pad chamber for very high readout rates
Energy Technology Data Exchange (ETDEWEB)
Spiegel, L.; Cataldi, G.; Elia, V.; Mazur, P.; Murphy, C.T.; Smith, R.P.; Yang, W. (Fermi National Accelerator Lab., Batavia, IL (United States)); Alexopoulos, T.; Durandet, C.; Erwin, A.; Jennings, J. (Wisconsin Univ., Madison, WI (United States)); Antoniazzi, L.; Introzzi, G.; Lanza, A.; Liguori, G.; Torre, P. (Pavia Univ. (Italy) Istituto Nazionale di Fisica Nucleare, Rome (Italy)); Arenton, M.; Conetti, S.
1991-11-01
Six medium-sized ({approx}1 {times} 2 m{sup 2}) drift chambers with pad and stripe readout have been constructed for and are presently operating in Fermi National Accelerator Laboratory experiment E-771. Each chamber module actually represents a pair of identical planes: two sets of anode wires, two sets of stripes, and two sets of pads. The wire planes are read out separately and represent X measurements in the coordinate system of the experiment. The twin stripe and pad planes are internally paired within the chamber modules; stripe signals represent Y measurements and pad signals combination X and Y measurements. Signals which develop on the stripes and pads are mirror (but inverted) images of what is seen on the wires. In addition to being used in the off-line pattern recognition, pad signals are also used as inputs to an on-line high transverse momentum (pt) trigger processor. While the techniques involved in the design and construction of the chambers are not novel, they may be of interest to experiments contemplating very large area, high rate chambers for future spectrometers.
International Nuclear Information System (INIS)
Sterpin, E.; Mackie, T. R.; Vynckier, S.
2012-01-01
Purpose: To determine k Q msr ,Q o f msr ,f o correction factors for machine-specific reference (msr) conditions by Monte Carlo (MC) simulations for reference dosimetry of TomoTherapy static beams for ion chambers Exradin A1SL, A12; PTW 30006, 31010 Semiflex, 31014 PinPoint, 31018 microLion; NE 2571. Methods: For the calibration of TomoTherapy units, reference conditions specified in current codes of practice like IAEA/TRS-398 and AAPM/TG-51 cannot be realized. To cope with this issue, Alfonso et al. [Med. Phys. 35, 5179–5186 (2008)] described a new formalism introducing msr factors k Q msr ,Q o f msr ,f o for reference dosimetry, applicable to static TomoTherapy beams. In this study, those factors were computed directly using MC simulations for Q 0 corresponding to a simplified 60 Co beam in TRS-398 reference conditions (at 10 cm depth). The msr conditions were a 10 × 5 cm 2 TomoTherapy beam, source-surface distance of 85 cm and 10 cm depth. The chambers were modeled according to technical drawings using the egs++ package and the MC simulations were run with the egs c hamber user code. Phase-space files used as the source input were produced using PENELOPE after simulation of a simplified 60 Co beam and the TomoTherapy treatment head modeled according to technical drawings. Correlated sampling, intermediate phase-space storage, and photon cross-section enhancement variance reduction techniques were used. The simulations were stopped when the combined standard uncertainty was below 0.2%. Results: Computed k Q msr ,Q o f msr ,f o values were all close to one, in a range from 0.991 for the PinPoint chamber to 1.000 for the Exradin A12 with a statistical uncertainty below 0.2%. Considering a beam quality Q defined as the TPR 20,10 for a 6 MV Elekta photon beam (0.661), the additional correction k Q msr, Q f msr, f ref to k Q,Q o defined in Alfonso et al. [Med. Phys. 35, 5179–5186 (2008)] formalism was in a range from 0.997 to 1.004.Conclusion: The MC computed
International Nuclear Information System (INIS)
Va'Vra, J.
1986-02-01
This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs
A simplified digital lock-in amplifier for the scanning grating spectrometer.
Wang, Jingru; Wang, Zhihong; Ji, Xufei; Liu, Jie; Liu, Guangda
2017-02-01
For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.
Directory of Open Access Journals (Sweden)
Peter Križan
2012-01-01
Full Text Available In this paper, we will present the impact of the conical shape of a pressing chamber, an important structural parameter. Besides the known impact of the technological parameters of pressing chambers, it is also very important to pay attention to their structural parameters. In the introduction, we present a theoretical analysis of pressing chamber conicalness. An experiment aimed at detecting this impact was performed at our institute, and it showed that increasing the conicalness of a pressing chamber improves the quality of the final briquettes. The conicalness of the pressing chamber has a significanteffect on the final briquette quality and on the construction of briquetting machines. The experimental findings presented here show the importance of this parameter in the briquetting process.
A lower cost development path for heavy ion fusion
International Nuclear Information System (INIS)
Hogan, W.J.; Meier, W.R.
1993-01-01
If two features of the inertial fusion process are exploited successfully, they can lead to significantly lower costs for demonstrating the feasibility of commercial electric power production from this source of energy. First, fusion capsule ignition and burn physics is independent of reaction chamber size and hydrodynamically-equivalent capsules can be designed to perform at small yield, exactly as they do at large yield. This means that an integrated test of all power plant components and feasibility tests of various reaction chamber concepts can be done at much smaller sizes (about 1--2 m first wall radius) and much lower powers (tens of MWs) than magnetic fusion development facilities such as ITER. Second, the driver, which is the most expensive component of currently conceived IFE development facilities, can be used to support more than one experiment target chamber/reactor (simultaneously and/or sequentially). These two factors lead to lower development facility costs, modular facilities, and the planning flexibility to spread costs over time or do several things in parallel and thus shorten the total time needed for development of Inertial Fusion Energy (IFE). In this paper the authors describe the general feature of a heavy ion fusion development plan that takes advantage of upgradable accelerators and the ability to test chambers and reactor systems at small scale in order to reduce development time and costs
On a nonlinear Kalman filter with simplified divided difference approximation
Luo, Xiaodong; Hoteit, Ibrahim; Moroz, Irene M.
2012-01-01
We present a new ensemble-based approach that handles nonlinearity based on a simplified divided difference approximation through Stirling's interpolation formula, which is hence called the simplified divided difference filter (sDDF). The sDDF uses Stirling's interpolation formula to evaluate the statistics of the background ensemble during the prediction step, while at the filtering step the sDDF employs the formulae in an ensemble square root filter (EnSRF) to update the background to the analysis. In this sense, the sDDF is a hybrid of Stirling's interpolation formula and the EnSRF method, while the computational cost of the sDDF is less than that of the EnSRF. Numerical comparison between the sDDF and the EnSRF, with the ensemble transform Kalman filter (ETKF) as the representative, is conducted. The experiment results suggest that the sDDF outperforms the ETKF with a relatively large ensemble size, and thus is a good candidate for data assimilation in systems with moderate dimensions. © 2011 Elsevier B.V. All rights reserved.
On a nonlinear Kalman filter with simplified divided difference approximation
Luo, Xiaodong
2012-03-01
We present a new ensemble-based approach that handles nonlinearity based on a simplified divided difference approximation through Stirling\\'s interpolation formula, which is hence called the simplified divided difference filter (sDDF). The sDDF uses Stirling\\'s interpolation formula to evaluate the statistics of the background ensemble during the prediction step, while at the filtering step the sDDF employs the formulae in an ensemble square root filter (EnSRF) to update the background to the analysis. In this sense, the sDDF is a hybrid of Stirling\\'s interpolation formula and the EnSRF method, while the computational cost of the sDDF is less than that of the EnSRF. Numerical comparison between the sDDF and the EnSRF, with the ensemble transform Kalman filter (ETKF) as the representative, is conducted. The experiment results suggest that the sDDF outperforms the ETKF with a relatively large ensemble size, and thus is a good candidate for data assimilation in systems with moderate dimensions. © 2011 Elsevier B.V. All rights reserved.
Use of simplified methods for predicting natural resource damages
International Nuclear Information System (INIS)
Loreti, C.P.; Boehm, P.D.; Gundlach, E.R.; Healy, E.A.; Rosenstein, A.B.; Tsomides, H.J.; Turton, D.J.; Webber, H.M.
1995-01-01
To reduce transaction costs and save time, the US Department of the Interior (DOI) and the National Oceanic and Atmospheric Administration (NOAA) have developed simplified methods for assessing natural resource damages from oil and chemical spills. DOI has proposed the use of two computer models, the Natural Resource Damage Assessment Model for Great Lakes Environments (NRDAM/GLE) and a revised Natural Resource Damage Assessment Model for Coastal and Marine Environments (NRDAM/CME) for predicting monetary damages for spills of oils and chemicals into the Great Lakes and coastal and marine environments. NOAA has used versions of these models to create Compensation Formulas, which it has proposed for calculating natural resource damages for oil spills of up to 50,000 gallons anywhere in the US. Based on a review of the documentation supporting the methods, the results of hundreds of sample runs of DOI's models, and the outputs of the thousands of model runs used to create NOAA's Compensation Formulas, this presentation discusses the ability of these simplified assessment procedures to make realistic damage estimates. The limitations of these procedures are described, and the need for validating the assumptions used in predicting natural resource injuries is discussed
Conceptual design study on simplified and safer cooling systems for sodium cooled FBRs
International Nuclear Information System (INIS)
Hayafune, Hiroki; Shimakawa, Yoshio; Ishikawa, Hiroyasu; Kubota, Kenichi; Kobayashi, Jun; Kasai, Shigeo
2000-06-01
The objective of this study is to create the FBR plant concepts increasing economy and safety for the Phase-I 'Feasibility Studies on Commercialized Fast Reactor System'. In this study, various concepts of simplified 2ry cooling system for sodium cooled FBRs are considered and evaluated from the view points of technological feasibility, economy, and safety. The concepts in the study are considered on the basis of the following points of view. 1. To simplify 2ry cooling system by moderating and localizing the sodium-water reaction in the steam generator of the FBRs. 2. To simplify 2ry cooling system by eliminating the sodium-water reaction using integrated IHX-SG unit. 3. To simplify 2ry cooling system by eliminating the sodium-water reaction using a power generating system other than the steam generator. As the result of the study, 12 concepts and 3 innovative concepts are proposed. The evaluation study for those concepts shows the following technical prospects. 1. 2 concepts of integrated IHX-SG unit can eliminate the sodium-water reaction. Separated IHX and SG tubes unit using Lead-Bismuth as the heat transfer medium. Integrated IHX-SG unit using copper as the heat transfer medium. 2. Cost reduction effect by simplified 2ry cooling system using integrated IHX-SG unit is estimated 0 to 5%. 3. All of the integrated IHX-SG unit concepts have more weight and larger size than conventional steam generator unit. The weight of the unit during transporting and lifting would limit capacity of heat transfer system. These evaluation results will be compared with the results in JFY 2000 and used for the Phase-II study. (author)
Sleeve reaction chamber system
Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA
2009-08-25
A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.
Dual-chamber inflatable oil boom
International Nuclear Information System (INIS)
Blair, R.M.; Tedeschi, E.T.
1993-01-01
An elongated floating material containment boom section is described having a normally vertical ballasted skirt depending from flotation means, and convertible from a flattened collapsed condition to a deployable condition wherein buoyancy chamber means extending along the upper edge of said skirt are inflated to expanded buoyant configuration, including: a gas-impervious sleeve extending along the upper edge of said normally vertical skirt forming a first outer collapsible and inflatable flotation chamber, a first inflation valve connecting the interior of said sleeve with the ambient atmosphere, through which gas under pressure may be introduced into said sleeve to inflate said first buoyant outer flotation chamber, elongated gas-impervious tube means positioned inside said outer flotation chamber and forming second collapsible and inflatable internal flotation bladder chamber means, second inflation valve means connecting the interior of said bladder means through said outer flotation chamber to the ambient atmosphere through which gas under pressure may be introduced into said bladder means to inflate it forming said second flotation chamber means inside said outer flotation chamber
CERN PhotoLab
1972-01-01
Looking up into the interior of BEBC bubble chamber from the expansion cylinder. At the top of the chamber two fish-eye lenses are installed and three other fish-eye ports are blanked off. In the centre is a heat exchanger.
CSIR Research Space (South Africa)
Atkins, AR
1968-01-01
Full Text Available The design and calibration of an ergometer for exercising subjects during calorimetric studies in the climate chamber, are described. The ergometer is built into the climatic chamber and forms an integral part of the whole instrumentation system foe...
Schaftenaar, Erik; Lecuona, Karin; Baarsma, Seerp; Meenken, Christina; Verjans, Georges; McIntyre, James; Peters, Remco
2015-09-22
Infectious uveitis is a significant cause of blindness in South Africa, especially among HIV-infected individuals. The visual outcome of uveitis depends on early clinical and laboratory diagnosis to guide therapeutic intervention. Analyses of aqueous humor, obtained by anterior chamber paracentesis, directs the differential diagnosis in infectious uveitis. However, although safe and potentially cost-effective, diagnostic anterior chamber paracentesis is not common practice in ophthalmic care across Africa. We seek to draw attention to this important procedure that could improve the diagnosis and prognosis of infectious uveitis.
Vacuum Chambers for LEP sections
1983-01-01
The picture shows sections of the LEP vacuum chambers to be installed in the dipole magnets (left) and in the quadrupoles (right). The dipole chamber has three channels: the beam chamber, the pumping duct where the NEG (non-evaporabe getter) is installed and the water channel for cooling (on top in the picture). The pumping duct is connected to the beam chamber through holes in the separating wall. The thick lead lining to shield radiation can also be seen. These chambers were manufactured as extruded aluminium alloy profiles.
Outline of cost-benefit analysis and a case study
Kellizy, A.
1978-01-01
The methodology of cost-benefit analysis is reviewed and a case study involving solar cell technology is presented. Emphasis is placed on simplifying the technique in order to permit a technical person not trained in economics to undertake a cost-benefit study comparing alternative approaches to a given problem. The role of economic analysis in management decision making is discussed. In simplifying the methodology it was necessary to restrict the scope and applicability of this report. Additional considerations and constraints are outlined. Examples are worked out to demonstrate the principles. A computer program which performs the computational aspects appears in the appendix.
International Nuclear Information System (INIS)
Golnik, N.; Zielczynski, M.
1999-01-01
The paper presents the design of ionization chamber devoted for the determination of the absolute value of the absorbed dose in tissue-equivalent material. The special attention was paid to ensure that the volume of the active gas cavity was constant and well known. A specific property of the chamber design is that the voltage insulators are 'invisible' from any point of the active volume. Such configuration ensures a very good time stability of the electrical field and defines the active volume. The active volume of the chamber was determined with accuracy of 0.3%. This resulted in accuracy of 0.8% in determination of the absorbed dose in the layer of material adherent to the gas cavity. The chamber was applied for calibration purposes at radiotherapy facility in Joint Institute for Nuclear Research in Dubna (Russia) and in the calibration laboratory of the Institute of Atomic Energy in Swierk. (author)
Simplified Models for LHC New Physics Searches
Alves, Daniele; Arora, Sanjay; Bai, Yang; Baumgart, Matthew; Berger, Joshua; Buckley, Matthew; Butler, Bart; Chang, Spencer; Cheng, Hsin-Chia; Cheung, Clifford; Chivukula, R.Sekhar; Cho, Won Sang; Cotta, Randy; D'Alfonso, Mariarosaria; El Hedri, Sonia; Essig, Rouven; Evans, Jared A.; Fitzpatrick, Liam; Fox, Patrick; Franceschini, Roberto; Freitas, Ayres; Gainer, James S.; Gershtein, Yuri; Gray, Richard; Gregoire, Thomas; Gripaios, Ben; Gunion, Jack; Han, Tao; Haas, Andy; Hansson, Per; Hewett, JoAnne; Hits, Dmitry; Hubisz, Jay; Izaguirre, Eder; Kaplan, Jared; Katz, Emanuel; Kilic, Can; Kim, Hyung-Do; Kitano, Ryuichiro; Koay, Sue Ann; Ko, Pyungwon; Krohn, David; Kuflik, Eric; Lewis, Ian; Lisanti, Mariangela; Liu, Tao; Liu, Zhen; Lu, Ran; Luty, Markus; Meade, Patrick; Morrissey, David; Mrenna, Stephen; Nojiri, Mihoko; Okui, Takemichi; Padhi, Sanjay; Papucci, Michele; Park, Michael; Park, Myeonghun; Perelstein, Maxim; Peskin, Michael; Phalen, Daniel; Rehermann, Keith; Rentala, Vikram; Roy, Tuhin; Ruderman, Joshua T.; Sanz, Veronica; Schmaltz, Martin; Schnetzer, Stephen; Schuster, Philip; Schwaller, Pedro; Schwartz, Matthew D.; Schwartzman, Ariel; Shao, Jing; Shelton, Jessie; Shih, David; Shu, Jing; Silverstein, Daniel; Simmons, Elizabeth; Somalwar, Sunil; Spannowsky, Michael; Spethmann, Christian; Strassler, Matthew; Su, Shufang; Tait, Tim; Thomas, Brooks; Thomas, Scott; Toro, Natalia; Volansky, Tomer; Wacker, Jay; Waltenberger, Wolfgang; Yavin, Itay; Yu, Felix; Zhao, Yue; Zurek, Kathryn
2012-01-01
This document proposes a collection of simplified models relevant to the design of new-physics searches at the LHC and the characterization of their results. Both ATLAS and CMS have already presented some results in terms of simplified models, and we encourage them to continue and expand this effort, which supplements both signature-based results and benchmark model interpretations. A simplified model is defined by an effective Lagrangian describing the interactions of a small number of new particles. Simplified models can equally well be described by a small number of masses and cross-sections. These parameters are directly related to collider physics observables, making simplified models a particularly effective framework for evaluating searches and a useful starting point for characterizing positive signals of new physics. This document serves as an official summary of the results from the "Topologies for Early LHC Searches" workshop, held at SLAC in September of 2010, the purpose of which was to develop a...
Mathupala, Saroj P.; Kiousis, Sam; Szerlip, Nicholas J.
2016-01-01
Background Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O2 concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system to monitor gas-phase O2, the cell-based data tend to be non-uniform due to the ad hoc nature of the experimental setup. Methodology With the availability of low-cost open-source microcontroller-based electronic project kits, it is now possible for researchers to program these with easy-to-use software, link them to sensors, and place them in basic scientific apparatus to monitor and record experimental parameters. We report here the design and construction of a small-footprint kit for continuous measurement and recording of O2 concentration in modular hypoxia chambers. The low-cost assembly (US$135) consists of an Arduino-based microcontroller, data-logging freeware, and a factory pre-calibrated miniature O2 sensor. A small, intuitive software program was written by the authors to control the data input and output. The basic nature of the kit will enable any student in biology with minimal experience in hobby-electronics to assemble the system and edit the program parameters to suit individual experimental conditions. Results/Conclusions We show the kit’s utility and stability of data output via a series of hypoxia experiments. The studies also demonstrated the critical need to monitor and adjust gas-phase O2 concentration during hypoxia-based experiments to prevent experimental errors or failure due to partial loss of hypoxia. Thus, incorporating the sensor-microcontroller module to a portable hypoxia chamber provides a researcher a capability that was previously available
Directory of Open Access Journals (Sweden)
Saroj P Mathupala
Full Text Available Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O2 concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system to monitor gas-phase O2, the cell-based data tend to be non-uniform due to the ad hoc nature of the experimental setup.With the availability of low-cost open-source microcontroller-based electronic project kits, it is now possible for researchers to program these with easy-to-use software, link them to sensors, and place them in basic scientific apparatus to monitor and record experimental parameters. We report here the design and construction of a small-footprint kit for continuous measurement and recording of O2 concentration in modular hypoxia chambers. The low-cost assembly (US$135 consists of an Arduino-based microcontroller, data-logging freeware, and a factory pre-calibrated miniature O2 sensor. A small, intuitive software program was written by the authors to control the data input and output. The basic nature of the kit will enable any student in biology with minimal experience in hobby-electronics to assemble the system and edit the program parameters to suit individual experimental conditions.We show the kit's utility and stability of data output via a series of hypoxia experiments. The studies also demonstrated the critical need to monitor and adjust gas-phase O2 concentration during hypoxia-based experiments to prevent experimental errors or failure due to partial loss of hypoxia. Thus, incorporating the sensor-microcontroller module to a portable hypoxia chamber provides a researcher a capability that was previously available only to labs with access to
Mathupala, Saroj P; Kiousis, Sam; Szerlip, Nicholas J
2016-01-01
Hypoxia-based cell culture experiments are routine and essential components of in vitro cancer research. Most laboratories use low-cost portable modular chambers to achieve hypoxic conditions for cell cultures, where the sealed chambers are purged with a gas mixture of preset O2 concentration. Studies are conducted under the assumption that hypoxia remains unaltered throughout the 48 to 72 hour duration of such experiments. Since these chambers lack any sensor or detection system to monitor gas-phase O2, the cell-based data tend to be non-uniform due to the ad hoc nature of the experimental setup. With the availability of low-cost open-source microcontroller-based electronic project kits, it is now possible for researchers to program these with easy-to-use software, link them to sensors, and place them in basic scientific apparatus to monitor and record experimental parameters. We report here the design and construction of a small-footprint kit for continuous measurement and recording of O2 concentration in modular hypoxia chambers. The low-cost assembly (US$135) consists of an Arduino-based microcontroller, data-logging freeware, and a factory pre-calibrated miniature O2 sensor. A small, intuitive software program was written by the authors to control the data input and output. The basic nature of the kit will enable any student in biology with minimal experience in hobby-electronics to assemble the system and edit the program parameters to suit individual experimental conditions. We show the kit's utility and stability of data output via a series of hypoxia experiments. The studies also demonstrated the critical need to monitor and adjust gas-phase O2 concentration during hypoxia-based experiments to prevent experimental errors or failure due to partial loss of hypoxia. Thus, incorporating the sensor-microcontroller module to a portable hypoxia chamber provides a researcher a capability that was previously available only to labs with access to sophisticated (and
International Nuclear Information System (INIS)
Frisken, W.R.
1977-01-01
A brief discussion is given of the use and operation of plastic flashtube chambers. Gas leaks, electric pulsing, the glow discharge, and readout methods are considered. Three distinct problems with high rate applications deal with resolving time, dead time, and polarization/neutralization of the chamber
Wire chambers: Trends and alternatives
Energy Technology Data Exchange (ETDEWEB)
Regler, Meinhard
1992-05-15
The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.
Prototype multiwire proportional chamber
1975-01-01
Chambers of this type were initially developed within the Alpha project (finally not approved). They were designed such to minimize the radiation length with a view to a mass spectrometer of high resolution meant to replace the Omega detector. The chambers were clearly forerunners for the (drift) chambers later built for R606 with the novel technique of crimping the wires. See also photo 7510039X.
Energy Technology Data Exchange (ETDEWEB)
Brogli, R.; Krakowski, R.A
2001-08-01
-protection metrics; b) a highly aggregated 'cost-equal-effort' or comparative-value method was applied to an array of commercial nuclear fuel forms in an effort to rank the attractiveness (to a proliferating agent) in terms of required effort as gauged through commercial costs; and c) the extension, if not actual application, of the system of Attractiveness Levels recommended by the USDOE as an extension and refinement of related IAEA protection-category guidelines. The Attractiveness-Level methodology, when compared to similar protection categories suggested by the IAEA, highlighted differences in required protection of specific source materials, with the IAEA being more conservative. From the viewpoint of a utility or research institute dealing with potential source materials, these differences can be important in budgetary terms. Both the 'cost-equal-effort' and the Attractiveness-Level methodologies were pursued to deal with conceptual and evaluation impasses encountered with the 'four-factor' formulation that were related primarily to the material-protection term necessary for its evaluation. The development, analyses, and evaluations performed to date on all three, inter-related approaches to simplified proliferation-risk metrics, as applied to the commercial nuclear fuel cycle, is reported. Key questions are discussed that must be resolved before a useful and simplified evaluation 'recipe' with which to evaluate proliferation risk and required protection levels (and cost) to nullify that risk is made available to the operator of a nuclear power plant and the total fuel cycle supporting it. (author)
International Nuclear Information System (INIS)
Brogli, R.; Krakowski, R.A.
2001-08-01
) a highly aggregated 'cost-equal-effort' or comparative-value method was applied to an array of commercial nuclear fuel forms in an effort to rank the attractiveness (to a proliferating agent) in terms of required effort as gauged through commercial costs; and c) the extension, if not actual application, of the system of Attractiveness Levels recommended by the USDOE as an extension and refinement of related IAEA protection-category guidelines. The Attractiveness-Level methodology, when compared to similar protection categories suggested by the IAEA, highlighted differences in required protection of specific source materials, with the IAEA being more conservative. From the viewpoint of a utility or research institute dealing with potential source materials, these differences can be important in budgetary terms. Both the 'cost-equal-effort' and the Attractiveness-Level methodologies were pursued to deal with conceptual and evaluation impasses encountered with the 'four-factor' formulation that were related primarily to the material-protection term necessary for its evaluation. The development, analyses, and evaluations performed to date on all three, inter-related approaches to simplified proliferation-risk metrics, as applied to the commercial nuclear fuel cycle, is reported. Key questions are discussed that must be resolved before a useful and simplified evaluation 'recipe' with which to evaluate proliferation risk and required protection levels (and cost) to nullify that risk is made available to the operator of a nuclear power plant and the total fuel cycle supporting it. (author)
Simplifying informed consent for biorepositories: stakeholder perspectives.
Beskow, Laura M; Friedman, Joëlle Y; Hardy, N Chantelle; Lin, Li; Weinfurt, Kevin P
2010-09-01
Complex and sometimes controversial information must be conveyed during the consent process for participation in biorepositories, and studies suggest that consent documents in general are growing in length and complexity. As a first step toward creating a simplified biorepository consent form, we gathered data from multiple stakeholders about what information was most important for prospective participants to know when making a decision about taking part in a biorepository. We recruited 52 research participants, 12 researchers, and 20 institutional review board representatives from Durham and Kannapolis, NC. These subjects were asked to read a model biorepository consent form and highlight sentences they deemed most important. On average, institutional review board representatives identified 72.3% of the sentences as important; researchers selected 53.0%, and participants 40.4% (P = 0.0004). Participants most often selected sentences about the kinds of individual research results that might be offered, privacy risks, and large-scale data sharing. Researchers highlighted sentences about the biorepository's purpose, privacy protections, costs, and participant access to individual results. Institutional review board representatives highlighted sentences about collection of basic personal information, medical record access, and duration of storage. The differing mandates of these three groups can translate into widely divergent opinions about what information is important and appropriate to include a consent form. These differences could frustrate efforts to move simplified forms--for biobanking as well as for other kinds of research--into actual use, despite continued calls for such forms.
International Nuclear Information System (INIS)
Alexeev, V.I.; Emelyanov, I.Y.; Ivanov, V.M.; Konstantinov, L.V.; Lysikov, B.V.; Postnikov, V.V.; Rybakov, J.V.
1976-01-01
A miniature ionization chamber having a gas-filled housing which accommodates a guard electrode made in the form of a hollow perforated cylinder is described. The cylinder is electrically associated with the intermediate coaxial conductor of a triaxial cable used as the lead-in of the ionization chamber. The gas-filled housing of the ionization chamber also accommodates a collecting electrode shaped as a rod electrically connected to the center conductor of the cable and to tubular members. The rod is disposed internally of the guard electrode and is electrically connected, by means of jumpers passing through the holes in the guard electrode, to the tubular members. The tubular members embrace the guard electrode and are spaced a certain distance apart along its entire length. Arranged intermediate of these tubular members are spacers secured to the guard electrode and fixing the collecting electrode throughout its length with respect to the housing of the ionization chamber
Wire chambers: Trends and alternatives
International Nuclear Information System (INIS)
Regler, Meinhard
1992-01-01
The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!
A new plant chamber facility PLUS coupled to the atmospheric simulation chamber SAPHIR
Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.
2015-11-01
A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been build and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees are mixed with synthetic air and are transferred to the SAPHIR chamber where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOC) can be studied in detail. In PLUS all important enviromental parameters (e.g. temperature, PAR, soil RH etc.) are well-controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leafes of the plants is constructed such that gases are exposed to FEP Teflon film and other Teflon surfaces only to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 LED panels which have an emission strength up to 800 μmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOC) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light and temperature dependent BVOC emissions are studied using six Quercus Ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus Ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental set up and the utility of the newly added plant chamber.
A new plant chamber facility, PLUS, coupled to the atmosphere simulation chamber SAPHIR
Hohaus, T.; Kuhn, U.; Andres, S.; Kaminski, M.; Rohrer, F.; Tillmann, R.; Wahner, A.; Wegener, R.; Yu, Z.; Kiendler-Scharr, A.
2016-03-01
A new PLant chamber Unit for Simulation (PLUS) for use with the atmosphere simulation chamber SAPHIR (Simulation of Atmospheric PHotochemistry In a large Reaction Chamber) has been built and characterized at the Forschungszentrum Jülich GmbH, Germany. The PLUS chamber is an environmentally controlled flow-through plant chamber. Inside PLUS the natural blend of biogenic emissions of trees is mixed with synthetic air and transferred to the SAPHIR chamber, where the atmospheric chemistry and the impact of biogenic volatile organic compounds (BVOCs) can be studied in detail. In PLUS all important environmental parameters (e.g., temperature, photosynthetically active radiation (PAR), soil relative humidity (RH)) are well controlled. The gas exchange volume of 9.32 m3 which encloses the stem and the leaves of the plants is constructed such that gases are exposed to only fluorinated ethylene propylene (FEP) Teflon film and other Teflon surfaces to minimize any potential losses of BVOCs in the chamber. Solar radiation is simulated using 15 light-emitting diode (LED) panels, which have an emission strength up to 800 µmol m-2 s-1. Results of the initial characterization experiments are presented in detail. Background concentrations, mixing inside the gas exchange volume, and transfer rate of volatile organic compounds (VOCs) through PLUS under different humidity conditions are explored. Typical plant characteristics such as light- and temperature- dependent BVOC emissions are studied using six Quercus ilex trees and compared to previous studies. Results of an initial ozonolysis experiment of BVOC emissions from Quercus ilex at typical atmospheric concentrations inside SAPHIR are presented to demonstrate a typical experimental setup and the utility of the newly added plant chamber.
Directed Energy Anechoic Chamber
Federal Laboratory Consortium — The Directed Energy Anechoic Chamber comprises a power anechoic chamber and one transverse electromagnetic cell for characterizing radiofrequency (RF) responses of...
1992-01-01
The real particles produced in the decay of a positive pion can be seen in this image from a streamer chamber. Streamer chambers consist of a gas chamber through which a strong pulsed electric field is passed, creating sparks as a charged particle passes through it. A magnetic field is added to cause the decay products to follow curved paths so that their charge and momentum can be measured.
1970-01-01
A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Commercializing the next generation: the AP600 advanced simplified nuclear power plant
International Nuclear Information System (INIS)
Bruschi, H.J.
1994-01-01
Today, government and industry are working together on advanced nuclear power plant designs that take advantage of valuable lessons learned from the experience to date and promise to reconcile the demands of economic expansion with the laws of environmental protection. In the U.S., the Department of Energy (DOE) and the Electric Power Research Institute (EPRI) initiated a design certification program in 1989 to develop and commercialize advanced light water reactors (ALWRs) for the next round of power plant construction. Advanced, simplified technology is one approach under development to end the industry's search for a simpler, more forgiving, and less costly reactor. As part of this program, Westinghouse is developing the AP600, a new standard 600 MWe advanced, simplified plant. The design strikes a balance between the use of proven technology and new approaches. The result is a greatly streamlined plant that can meet safety regulations and reliability requirements, be economically competitive, and promote broader public confidence in nuclear energy. 1 fig
CERN PhotoLab
1968-01-01
In these chambers each wire is an independent proportional counter with its own amplifier and logic circuit. The low cost of the associated electronics makes realistic moderately large systems, with thousands of wires. The resolution time of each wire is of the order of 100 ns, with 3mm spacing. Roger Bouclier is working on an early model tested in a PS beam-line.
Pencil-shaped radiation detection ionization chamber
International Nuclear Information System (INIS)
Suzuki, A.
1979-01-01
A radiation detection ionization chamber is described. It consists of an elongated cylindrical pencil-shaped tubing forming an outer wall of the chamber and a center electrode disposed along the major axis of the tubing. The length of the chamber is substantially greater than the diameter. A cable connecting portion at one end of the chamber is provided for connecting the chamber to a triaxial cable. An end support portion is connected at the other end of the chamber for supporting and tensioning the center electrode. 17 claims
Road to Grid Parity through Deployment of Low-Cost 21.5% N-Type Si Solar Cells
Energy Technology Data Exchange (ETDEWEB)
Velundur, Vijay [Suniva, Norcross, GA (United States)
2017-04-19
This project seeks to develop and deploy differentiated 21.5% efficient n-type Si solar cells while reaching the SunShot module cost goal of ≤ $0.50/W. This objective hinges on development of enabling low cost technologies that simplify the manufacturing process and reduce overall processing costs. These comprise of (1) Boron emitter formation and passivation; (2) Simplified processing process for emitter and BSF layers; and (3) Advanced metallization for the front and back contacts.
Directory of Open Access Journals (Sweden)
Wenhua Yuan
2014-10-01
Full Text Available In order to improve combustion characteristic of swirl chamber diesel engine, a simulation model about a traditional cylindrical flat-bottom swirl chamber turbulent combustion diesel engine was established within the timeframe of the piston motion from the bottom dead centre (BDC to the top dead centre (TDC with the fluent dynamic mesh technique and flow field vector of gas in swirl chamber and cylinder; the pressure variation and temperature variation were obtained and a new type of swirl chamber structure was proposed. The results reveal that the piston will move from BDC; air in the cylinder is compressed into the swirl chamber by the piston to develop a swirl inside the chamber, with the ongoing of compression; the pressure and temperature are also rising gradually. Under this condition, the demand of diesel oil mixing and combusting will be better satisfied. Moreover, the new structure will no longer forma small fluid retention zone at the lower end outside the chamber and will be more beneficial to the mixing of fuel oil and air, which has presented a new idea and theoretical foundation for the design and optimization of swirl chamber structure and is thus of good significance of guiding in this regard.
Diogene pictorial drift chamber
International Nuclear Information System (INIS)
Gosset, J.
1984-01-01
A pictorial drift chamber, called DIOGENE, has been installed at Saturne in order to study central collisions of high energy heavy ions. It has been adapted from the JADE internal detector, with two major differences to be taken into account. First, the center-of-mass of these collisions is not identical to the laboratory reference frame. Second, the energy loss and the momentum ranges of the particles to be detected are different from the ones in JADE. It was also tried to keep the cost as small as possible, hence the choice of minimum size and minimum number of sensitive wires. Moreover the wire planes are shifted from the beam axis: this trick helps very much to quickly reject the bad tracks caused by the ambiguity of measuring drift distances (positive or negative) through times (always positive)
Simplified model of a PWR primary coolant circuit
International Nuclear Information System (INIS)
Souza, A.L. de; Faya, A.J.G.
1988-01-01
The computer program RENUR was developed to perform a very simplified simulation of a typical PWR primary circuit. The program has mathematical models for the thermal-hydraulics of the reactor core and the pressurizer, the rest of the circuit being treated as a single volume. Heat conduction in the fuel rod is analysed by a nodal model. Average and hot channels are treated so that the bulk response of the core and DNBR can be evaluated. A Homogenenous model is employed in the pressurizer. Results are presented for a steady-state situation as well as for a loss of load transient. Agreement with the results of more elaborate computer codes is good with substantial reduction in computer costs. (author) [pt
Simplified proceeding as a civil procedure model
Directory of Open Access Journals (Sweden)
Олексій Юрійович Зуб
2016-01-01
Full Text Available Currently the directions for the development of modern civil procedural law such as optimization, facilitation, forwarding proceedings promoting the increase of the civil procedure efficiency factor are of peculiar importance. Their results are occurrence and functionality of simplified proceedings system designed to facilitate significantly hearing some categories of cases, promotion of their consideration within reasonable time and reduce legal expenses so far as it is possible. The category “simplified proceedings” in the native science of the procedural law is underexamined. A good deal of scientists-processualists were limited to studying summary (in the context of optimization as a way to improve the civil procedural form, summary proceedings and procedures functioning in terms of the mentioned proceedings, consideration of case in absentia as well as their modification. Among the Ukrainian scientist who studied some aspects of the simplified proceedings are: E. A. Belyanevych, V. I. Bobrik, S. V. Vasilyev, M. V. Verbitska, S. I. Zapara, A. A. Zgama, V. V. Komarov, D. D. Luspenuk, U. V. Navrotska, V. V. Protsenko, T. V. Stepanova, E. A. Talukin, S. Y. Fursa, M. Y. Shtefan others. The problems of the simplified proceedings were studied by the foreign scientists as well, such as: N. Andrews, Y. Y. Grubanon, N. A. Gromoshina, E. P. Kochanenko, J. Kohler, D. I. Krumskiy, E. M. Muradjan, I. V. Reshetnikova, U. Seidel, N. V. Sivak, M. Z. Shvarts, V. V. Yarkov and others. The paper objective is to develop theoretically supported, practically reasonable notion of simplified proceedings in the civil process, and also basing on the notion of simplified proceedings, international experience of the legislative regulation of simplified proceedings, native and foreign doctrine, to distinguish essential features of simplified proceedings in the civil process and to describe them. In the paper we generated the notion of simplified proceedings that
Simulation of mercury capture by sorbent injection using a simplified model.
Zhao, Bingtao; Zhang, Zhongxiao; Jin, Jing; Pan, Wei-Ping
2009-10-30
Mercury pollution by fossil fuel combustion or solid waste incineration is becoming the worldwide environmental concern. As an effective control technology, powdered sorbent injection (PSI) has been successfully used for mercury capture from flue gas with advantages of low cost and easy operation. In order to predict the mercury capture efficiency for PSI more conveniently, a simplified model, which is based on the theory of mass transfer, isothermal adsorption and mass balance, is developed in this paper. The comparisons between theoretical results of this model and experimental results by Meserole et al. [F.B. Meserole, R. Chang, T.R. Carrey, J. Machac, C.F.J. Richardson, Modeling mercury removal by sorbent injection, J. Air Waste Manage. Assoc. 49 (1999) 694-704] demonstrate that the simplified model is able to provide good predictive accuracy. Moreover, the effects of key parameters including the mass transfer coefficient, sorbent concentration, sorbent physical property and sorbent adsorption capacity on mercury adsorption efficiency are compared and evaluated. Finally, the sensitive analysis of impact factor indicates that the injected sorbent concentration plays most important role for mercury capture efficiency.
Establishment of a radon test chamber
International Nuclear Information System (INIS)
Chen Chingjiang; Liu Chichang; Lin Yuming
1993-01-01
A walk-in type radon test chamber of 23 m 3 has been built for testing and calibration of radon measurement instruments. The environmental conditions of the test chamber can be varied within a wide range of values. The design objectives specification, monitoring instruments and testing results of this chamber are discussed. This test chamber is available for domestic radon researchers and its accuracy can be traced to the international standard. A routine intercomparison study will be held annually by using this chamber. Other tests like radon progeny and thoron standard may also be performed in this chamber. (1 fig.)
Tax compliance costs: a business administration perspective
Eichfelder, Sebastian; Schorn, Michael
2009-01-01
The paper analyses the relationship of tax compliance costs and business strategy. Due to instruments, like information technology, simplified cash accounting or outsourcing compliance activities to tax advisers, private businesses have a set of strategies to optimize their tax compliance cost burden. Under the assumption of rational choice a private business should choose a cost-optimal administration strategy. In spite of that we find empirical evidence for small German businesses using onl...
International Nuclear Information System (INIS)
Perini, Ana Paula
2013-01-01
Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this PhD program. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system. (author)
Simplified Method of Optimal Sizing of a Renewable Energy Hybrid System for Schools
Directory of Open Access Journals (Sweden)
Jiyeon Kim
2016-11-01
Full Text Available Schools are a suitable public building for renewable energy systems. Renewable energy hybrid systems (REHSs have recently been introduced in schools following a new national regulation that mandates renewable energy utilization. An REHS combines the common renewable-energy sources such as geothermal heat pumps, solar collectors for water heating, and photovoltaic systems with conventional energy systems (i.e., boilers and air-source heat pumps. Optimal design of an REHS by adequate sizing is not a trivial task because it usually requires intensive work including detailed simulation and demand/supply analysis. This type of simulation-based approach for optimization is difficult to implement in practice. To address this, this paper proposes simplified sizing equations for renewable-energy systems of REHSs. A conventional optimization process is used to calculate the optimal combinations of an REHS for cases of different numbers of classrooms and budgets. On the basis of the results, simplified sizing equations that use only the number of classrooms as the input are proposed by regression analysis. A verification test was carried out using an initial conventional optimization process. The results show that the simplified sizing equations predict similar sizing results to the initial process, consequently showing similar capital costs within a 2% error.
National Ignition Facility Target Chamber
International Nuclear Information System (INIS)
Wavrik, R W; Cox, J R; Fleming, P J
2000-01-01
On June 11, 1999 the Department of Energy dedicated the single largest piece of the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) in Livermore, California. The ten (10) meter diameter aluminum target high vacuum chamber will serve as the working end of the largest laser in the world. The output of 192 laser beams will converge at the precise center of the chamber. The laser beams will enter the chamber in two by two arrays to illuminate 10 millimeter long gold cylinders called hohlraums enclosing 2 millimeter capsule containing deuterium, tritium and isotopes of hydrogen. The two isotopes will fuse, thereby creating temperatures and pressures resembling those found only inside stars and in detonated nuclear weapons, but on a minute scale. The NIF Project will serve as an essential facility to insure safety and reliability of our nation's nuclear arsenal as well as demonstrating inertial fusion's contribution to creating electrical power. The paper will discuss the requirements that had to be addressed during the design, fabrication and testing of the target chamber. A team from Sandia National Laboratories (SNL) and LLNL with input from industry performed the configuration and basic design of the target chamber. The method of fabrication and construction of the aluminum target chamber was devised by Pitt-Des Moines, Inc. (PDM). PDM also participated in the design of the chamber in areas such as the Target Chamber Realignment and Adjustment System, which would allow realignment of the sphere laser beams in the event of earth settlement or movement from a seismic event. During the fabrication of the target chamber the sphericity tolerances had to be addressed for the individual plates. Procedures were developed for forming, edge preparation and welding of individual plates. Construction plans were developed to allow the field construction of the target chamber to occur parallel to other NIF construction activities. This was
Berge, J A; Gramstad, L; Grimnes, S
1995-05-01
Modern anaesthetic machines are equipped with several safety components to prevent delivery of hypoxic mixtures. However, such a technical development has increased the complexity of the equipment. We report a reconstructed anaesthetic machine in which a paramagnetic oxygen analyzer has provided the means to simplify the apparatus. The new machine is devoid of several components conventionally included to prevent hypoxic mixtures: oxygen failure protection device, reservoir O2 alarm, N2O/air selector, and proportioning system for oxygen/nitrous oxide delivery. These devices have been replaced by a simple safety system using a paramagnetic oxygen analyzer at the common gas outlet, which in a feed-back system cuts off the supply of nitrous oxide whenever the oxygen concentration falls below 25%. The simplified construction of the anaesthetic machine has important consequences for safety, cost and user-friendliness. Reducing the complexity of the construction also simplifies the pre-use checkout procedure, and an efficient 5-point check list is presented for the new machine.
Kazemi, S; Wirostko, W J; Sinha, S; Mieler, W F; Koenig, S B; Sheth, B P
2000-01-01
To review our experience with combined pars plana lensectomy-vitrectomy and open-loop flexible anterior chamber intraocular lens (AC IOL) implantation for managing subluxated crystalline lenses. Retrospective review of 36 consecutive eyes (28 patients), all of which had subluxated crystalline lenses, managed by pars plana lensectomy-vitrectomy with insertion of an open-loop flexible AC IOL. The study was performed at the Medical College of Wisconsin, Milwaukee, over an 8-year period. An average preoperative visual acuity of 20/163 (range, 20/25 to hand motions) improved to 20/36 (range, 20/20 to 4/200) with surgery after a mean follow-up of 14 months (range, 1 to 59 months) (P IOL implantation appears to be an excellent technique for managing subluxated crystalline lenses. It is associated with a significant improvement in visual acuity (P subluxated lens through a limbal wound. Additionally, use of an AC IOL offers a simplified alternative to placement of a ciliary sulcus sutured posterior chamber intraocular lens (PC IOL).
Simplified Models for LHC New Physics Searches
International Nuclear Information System (INIS)
Alves, Daniele; Arkani-Hamed, Nima; Arora, Sanjay; Bai, Yang; Baumgart, Matthew; Berger, Joshua; Butler, Bart; Chang, Spencer; Cheng, Hsin-Chia; Cheung, Clifford; Chivukula, R. Sekhar; Cho, Won Sang; Cotta, Randy; D'Alfonso, Mariarosaria; El Hedri, Sonia; Essig, Rouven; Fitzpatrick, Liam; Fox, Patrick; Franceschini, Roberto
2012-01-01
This document proposes a collection of simplified models relevant to the design of new-physics searches at the LHC and the characterization of their results. Both ATLAS and CMS have already presented some results in terms of simplified models, and we encourage them to continue and expand this effort, which supplements both signature-based results and benchmark model interpretations. A simplified model is defined by an effective Lagrangian describing the interactions of a small number of new particles. Simplified models can equally well be described by a small number of masses and cross-sections. These parameters are directly related to collider physics observables, making simplified models a particularly effective framework for evaluating searches and a useful starting point for characterizing positive signals of new physics. This document serves as an official summary of the results from the 'Topologies for Early LHC Searches' workshop, held at SLAC in September of 2010, the purpose of which was to develop a set of representative models that can be used to cover all relevant phase space in experimental searches. Particular emphasis is placed on searches relevant for the first ∼ 50-500 pb -1 of data and those motivated by supersymmetric models. This note largely summarizes material posted at http://lhcnewphysics.org/, which includes simplified model definitions, Monte Carlo material, and supporting contacts within the theory community. We also comment on future developments that may be useful as more data is gathered and analyzed by the experiments.
Simplified Models for LHC New Physics Searches
Energy Technology Data Exchange (ETDEWEB)
Alves, Daniele; /SLAC; Arkani-Hamed, Nima; /Princeton, Inst. Advanced Study; Arora, Sanjay; /Rutgers U., Piscataway; Bai, Yang; /SLAC; Baumgart, Matthew; /Johns Hopkins U.; Berger, Joshua; /Cornell U., Phys. Dept.; Buckley, Matthew; /Fermilab; Butler, Bart; /SLAC; Chang, Spencer; /Oregon U. /UC, Davis; Cheng, Hsin-Chia; /UC, Davis; Cheung, Clifford; /UC, Berkeley; Chivukula, R.Sekhar; /Michigan State U.; Cho, Won Sang; /Tokyo U.; Cotta, Randy; /SLAC; D' Alfonso, Mariarosaria; /UC, Santa Barbara; El Hedri, Sonia; /SLAC; Essig, Rouven, (ed.); /SLAC; Evans, Jared A.; /UC, Davis; Fitzpatrick, Liam; /Boston U.; Fox, Patrick; /Fermilab; Franceschini, Roberto; /LPHE, Lausanne /Pittsburgh U. /Argonne /Northwestern U. /Rutgers U., Piscataway /Rutgers U., Piscataway /Carleton U. /CERN /UC, Davis /Wisconsin U., Madison /SLAC /SLAC /SLAC /Rutgers U., Piscataway /Syracuse U. /SLAC /SLAC /Boston U. /Rutgers U., Piscataway /Seoul Natl. U. /Tohoku U. /UC, Santa Barbara /Korea Inst. Advanced Study, Seoul /Harvard U., Phys. Dept. /Michigan U. /Wisconsin U., Madison /Princeton U. /UC, Santa Barbara /Wisconsin U., Madison /Michigan U. /UC, Davis /SUNY, Stony Brook /TRIUMF; /more authors..
2012-06-01
This document proposes a collection of simplified models relevant to the design of new-physics searches at the LHC and the characterization of their results. Both ATLAS and CMS have already presented some results in terms of simplified models, and we encourage them to continue and expand this effort, which supplements both signature-based results and benchmark model interpretations. A simplified model is defined by an effective Lagrangian describing the interactions of a small number of new particles. Simplified models can equally well be described by a small number of masses and cross-sections. These parameters are directly related to collider physics observables, making simplified models a particularly effective framework for evaluating searches and a useful starting point for characterizing positive signals of new physics. This document serves as an official summary of the results from the 'Topologies for Early LHC Searches' workshop, held at SLAC in September of 2010, the purpose of which was to develop a set of representative models that can be used to cover all relevant phase space in experimental searches. Particular emphasis is placed on searches relevant for the first {approx} 50-500 pb{sup -1} of data and those motivated by supersymmetric models. This note largely summarizes material posted at http://lhcnewphysics.org/, which includes simplified model definitions, Monte Carlo material, and supporting contacts within the theory community. We also comment on future developments that may be useful as more data is gathered and analyzed by the experiments.
Low Cost Upper Stage-Class Propulsion (LCUSP)
Vickers, John
2015-01-01
NASA is making space exploration more affordable and viable by developing and utilizing innovative manufacturing technologies. Technology development efforts at NASA in propulsion are committed to continuous innovation of design and manufacturing technologies for rocket engines in order to reduce the cost of NASA's journey to Mars. The Low Cost Upper Stage-Class Propulsion (LCUSP) effort will develop and utilize emerging Additive Manufacturing (AM) to significantly reduce the development time and cost for complex rocket propulsion hardware. Benefit of Additive Manufacturing (3-D Printing) Current rocket propulsion manufacturing techniques are costly and have lengthy development times. In order to fabricate rocket engines, numerous complex parts made of different materials are assembled in a way that allow the propellant to collect heat at the right places to drive the turbopump and simultaneously keep the thrust chamber from melting. The heat conditioned fuel and oxidizer come together and burn inside the combustion chamber to provide thrust. The efforts to make multiple parts precisely fit together and not leak after experiencing cryogenic temperatures on one-side and combustion temperatures on the other is quite challenging. Additive manufacturing has the potential to significantly reduce the time and cost of making rocket parts like the copper liner and Nickel-alloy jackets found in rocket combustion chambers where super-cold cryogenic propellants are heated and mixed to the extreme temperatures needed to propel rockets in space. The Selective Laser Melting (SLM) machine fuses 8,255 layers of copper powder to make a section of the chamber in 10 days. Machining an equivalent part and assembling it with welding and brazing techniques could take months to accomplish with potential failures or leaks that could require fixes. The design process is also enhanced since it does not require the 3D model to be converted to 2-D drawings. The design and fabrication process
Simplified Stability Criteria for Delayed Neutral Systems
Directory of Open Access Journals (Sweden)
Xinghua Zhang
2014-01-01
Full Text Available For a class of linear time-invariant neutral systems with neutral and discrete constant delays, several existing asymptotic stability criteria in the form of linear matrix inequalities (LMIs are simplified by using matrix analysis techniques. Compared with the original stability criteria, the simplified ones include fewer LMI variables, which can obviously reduce computational complexity. Simultaneously, it is theoretically shown that the simplified stability criteria and original ones are equivalent; that is, they have the same conservativeness. Finally, a numerical example is employed to verify the theoretic results investigated in this paper.
DEFF Research Database (Denmark)
Gfader, Verina
Cloud Chamber takes its roots in a performance project, titled The Guests 做东, devised by Verina Gfader for the 11th Shanghai Biennale, ‘Why Not Ask Again: Arguments, Counter-arguments, and Stories’. Departing from the inclusion of the biennale audience to write a future folk tale, Cloud Chamber......: fiction and translation and translation through time; post literacy; world picturing-world typing; and cartographic entanglements and expressions of subjectivity; through the lens a social imaginary of worlding or cosmological quest. Art at its core? Contributions by Nikos Papastergiadis, Rebecca Carson...
A simplified technique for shakedown limit load determination
International Nuclear Information System (INIS)
Abdalla, Hany F.; Megahed, Mohammad M.; Younan, Maher Y.A.
2007-01-01
In this paper, a simplified technique is presented to determine the shakedown limit load of a structure using the finite element method. The simplified technique determines the shakedown limit load without performing lengthy time consuming full elastic-plastic cyclic loading simulations or conventional iterative elastic techniques. Instead, the shakedown limit load is determined by performing two analyses namely: an elastic analysis and an elastic-plastic analysis. By extracting the results of the two analyses, the shakedown limit load is determined through the calculation of the residual stresses developed within the structure. The simplified technique is applied and verified using two bench mark shakedown problems namely: the two-bar structure subjected to constant axial force and cyclic thermal loading, and the Bree cylinder subjected to constant internal pressure and cyclic high temperature variation across its wall. The results of the simplified technique showed very good correlation with the, analytically determined, Bree diagrams of both structures. In order to gain confidence in the simplified technique, the shakedown limit loads output by the simplified technique are used to perform full elastic-plastic cyclic loading simulations to check for shakedown behavior of both structures
Simplified design of filter circuits
Lenk, John
1999-01-01
Simplified Design of Filter Circuits, the eighth book in this popular series, is a step-by-step guide to designing filters using off-the-shelf ICs. The book starts with the basic operating principles of filters and common applications, then moves on to describe how to design circuits by using and modifying chips available on the market today. Lenk's emphasis is on practical, simplified approaches to solving design problems.Contains practical designs using off-the-shelf ICsStraightforward, no-nonsense approachHighly illustrated with manufacturer's data sheets
A Simplified, Low-Cost Method for Polarized Light Microscopy
Maude, Richard J.; Buapetch, Wanchana; Silamut, Kamolrat
2009-01-01
Malaria pigment is an intracellular inclusion body that appears in blood and tissue specimens on microscopic examination and can help in establishing the diagnosis of malaria. In simple light microscopy, it can be difficult to discern from cellular background and artifacts. It has long been known that if polarized light microscopy is used, malaria pigment can be much easier to distinguish. However, this technique is rarely used because of the need for a relatively costly polarization microscope. We describe a simple and economical technique to convert any standard light microscope suitable for examination of malaria films into a polarization microscope. PMID:19861611
Directory of Open Access Journals (Sweden)
Andréia Fróes Galuci Oliveira
2011-11-01
Full Text Available A total of 70 five-month-old female New Zealand White rabbits were assigned in a completely randomized design, over three reproductive cycles, with two treatments: a reference diet and a half-simplified diet containing 79.83% cassava byproduct. The study evaluated body weight and feed intake of does, feed cost, number and total body weight of kits at kindling and weaning per female during three cycles, number and percentage of mortality/female/cycle, and weight gain of kits from birth to weaning. No interaction was observed between the diets and among the reproductive cycles for any evaluated characteristics. The body weight of does at the moment of weaning was similar in both groups for all three reproductive cycles. However, does fed the half-simplified diet had lower feed intake during the three reproductive cycles and, consequently, more reproductive flaws. The number of kits at weaning, body weight of kits at kindling and weaning, weight gain of kits from birth to weaning, and total body weight of kits at weaning were lower for the group of does fed the half-simplified diet and, consequently, there was a higher number and percentage of dead kits in this group. The total numbers of kits at kindling and weaning and total body weight of kits at birth during all three reproductive cycles were similar between the groups; however, total body weight of weaning rabbits was higher for the animals receiving the reference diet. It is possible to conclude that although the use of the half-simplified diet decreases the reproductive performance of does, it reduces feed cost per kg of body weight by 23.63% compared with the reference diet, proving to be a viable nutritional option for rabbit production.
The engineering development of an actively controlled precise muon chamber for the SDC detector
International Nuclear Information System (INIS)
Ayer, F.; Berk, E.; Gorman, J.; Govignon, J.; Sullivan, D.
1992-01-01
As the detector configuration for the Solenoidal Detector Collaboration (SDC) evolved, a number of concepts for MUON chambers were proposed and investigated. The Boston Group (Brandeis, Harvard and Tufts Universities, with Draper Laboratory) has developed a concept incorporating elliptical section drift tubes with field shaping and intermediate wire supports. This approach combines good single and multi-track resolution with a small channel count and modularity at the tube level. Other concepts have been developed which arise from differing interpretations of the fundamental physics and economic requirements. These include: Octagonal Drift Tubes, Unsupported Wires, No Field Shaping, U. Wisconsin; Round Tubes, Unsupported Wires, w or w/o Field Shaping, U. Washington; JFT Chambers (Multi-Wire, Intermediate Support, Field Shaping), KEK, Japan. This paper outlines the mechanical implementation of the Boston MUON chamber concept and discusses the rationale for several key design decisions imposed by the stringent mechanical tolerances. A prototype MUON chamber designed to verify design feasibility, performance, and cost is also described. A special section is devoted to the design and development of an optical alignment system within the chamber, which provides error signals driving the intermediate supports to true position. The Boston subgroup MUON chamber design is called the wine rack concept by virtue of its numerous (non-structural) drift tubes laid into a supporting chamber, which provides structural and handling capability. A number of individual θ,φ, and Stereo chambers is normally grouped into a supermodule, which in turn is assembled into a multi-layer supertower. Supertowers are the basic elements of the SDC MUON System, each comprising three supermodule layers in the barrel region and five in the forward regions
Directory of Open Access Journals (Sweden)
A Saravanakumar
2015-01-01
Full Text Available In the present work, a pediatric head and body phantom was fabricated using polymethyl methacrylate (PMMA at a low cost when compared to commercially available phantoms for the purpose of computed tomography (CT dosimetry. The dimensions of head and body phantoms were 10 cm diameter, 15 cm length and 16 cm diameter, 15 cm length, respectively. The dose from a 128-slice CT machine received by the head and body phantom at the center and periphery were measured using a 100 mm pencil ion chamber and 150 mm CT dose profiler (CTDP. Using these values, the weighted computed tomography dose index (CTDIw and in turn the volumetric CTDI (CTDIv were calculated for various combinations of tube voltage and current-time product. A similar study was carried out using standard calibrated phantom and the results have been compared with the fabricated ones to ascertain that the performance of the latter is equivalent to that of the former. Finally, CTDIv measured using fabricated and standard phantoms were compared with respective values displayed on the console. The difference between the values was well within the limits specified by Atomic Energy Regulatory Board (AERB, India. These results indicate that the cost-effective pediatric phantom can be employed for CT dosimetry.
S-Channel Dark Matter Simplified Models and Unitarity
Englert, Christoph; Spannowsky, Michael
The ultraviolet structure of $s$-channel mediator dark matter simplified models at hadron colliders is considered. In terms of commonly studied $s$-channel mediator simplified models it is argued that at arbitrarily high energies the perturbative description of dark matter production in high energy scattering at hadron colliders will break down in a number of cases. This is analogous to the well documented breakdown of an EFT description of dark matter collider production. With this in mind, to diagnose whether or not the use of simplified models at the LHC is valid, perturbative unitarity of the scattering amplitude in the processes relevant to LHC dark matter searches is studied. The results are as one would expect: at the LHC and future proton colliders the simplified model descriptions of dark matter production are in general valid. As a result of the general discussion, a simple new class of previously unconsidered `Fermiophobic Scalar' simplified models is proposed, in which a scalar mediator couples to...
Small Habitat Commonality Reduces Cost for Human Mars Missions
Griffin, Brand N.; Lepsch, Roger; Martin, John; Howard, Robert; Rucker, Michelle; Zapata, Edgar; McCleskey, Carey; Howe, Scott; Mary, Natalie; Nerren, Philip (Inventor)
2015-01-01
Most view the Apollo Program as expensive. It was. But, a human mission to Mars will be orders of magnitude more difficult and costly. Recently, NASA's Evolvable Mars Campaign (EMC) mapped out a step-wise approach for exploring Mars and the Mars-moon system. It is early in the planning process but because approximately 80% of the total life cycle cost is committed during preliminary design, there is an effort to emphasize cost reduction methods up front. Amongst the options, commonality across small habitat elements shows promise for consolidating the high bow-wave costs of Design, Development, Test and Evaluation (DDT&E) while still accommodating each end-item's functionality. In addition to DDT&E, there are other cost and operations benefits to commonality such as reduced logistics, simplified infrastructure integration and with inter-operability, improved safety and simplified training. These benefits are not without a cost. Some habitats are sub-optimized giving up unique attributes for the benefit of the overall architecture and because the first item sets the course for those to follow, rapidly developing technology may be excluded. The small habitats within the EMC include the pressurized crew cabins for the ascent vehicle,
A simplified approach for simulation of wake meandering
Energy Technology Data Exchange (ETDEWEB)
Thomsen, Kenneth; Aagaard Madsen, H.; Larsen, Gunner; Juul Larsen, T.
2006-03-15
This fact-sheet describes a simplified approach for a part of the recently developed dynamic wake model for aeroelastic simulations for wind turbines operating in wake. The part described in this fact-sheet concern the meandering process only, while the other part of the simplified approach the wake deficit profile is outside the scope of the present fact-sheet. Work on simplified models for the wake deficit profile is ongoing. (au)
On equivalent parameter learning in simplified feature space based on Bayesian asymptotic analysis.
Yamazaki, Keisuke
2012-07-01
Parametric models for sequential data, such as hidden Markov models, stochastic context-free grammars, and linear dynamical systems, are widely used in time-series analysis and structural data analysis. Computation of the likelihood function is one of primary considerations in many learning methods. Iterative calculation of the likelihood such as the model selection is still time-consuming though there are effective algorithms based on dynamic programming. The present paper studies parameter learning in a simplified feature space to reduce the computational cost. Simplifying data is a common technique seen in feature selection and dimension reduction though an oversimplified space causes adverse learning results. Therefore, we mathematically investigate a condition of the feature map to have an asymptotically equivalent convergence point of estimated parameters, referred to as the vicarious map. As a demonstration to find vicarious maps, we consider the feature space, which limits the length of data, and derive a necessary length for parameter learning in hidden Markov models. Copyright © 2012 Elsevier Ltd. All rights reserved.
1985-01-01
Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Optical analysis for simplified astigmatic correction of non-imaging focusing heliostat
Energy Technology Data Exchange (ETDEWEB)
Chong, K.K. [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Off Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur (Malaysia)
2010-08-15
In the previous work, non-imaging focusing heliostat that consists of m x n facet mirrors can carry out continuous astigmatic correction during sun-tracking with the use of only (m + n - 2) controllers. For this paper, a simplified astigmatic correction of non-imaging focusing heliostat is proposed for reducing the number of controllers from (m + n - 2) to only two. Furthermore, a detailed optical analysis of the new proposal has been carried out and the simulated result has shown that the two-controller system can perform comparably well in astigmatic correction with a much simpler and more cost effective design. (author)
Criteria for controlled atmosphere chambers
International Nuclear Information System (INIS)
Robinson, J.N.
1980-03-01
The criteria for design, construction, and operation of controlled atmosphere chambers intended for service at ORNL are presented. Classification of chambers, materials for construction, design criteria, design, controlled atmosphere chamber systems, and operating procedures are presented. ORNL Safety Manual Procedure 2.1; ORNL Health Physics Procedure Manual Appendix A-7; and Design of Viewing Windows are included in 3 appendices
Proceedings of workshop on streamer chamber
International Nuclear Information System (INIS)
Itoh, Hidihiko; Takahashi, Kaoru; Hirose, Tachishige; Masaike, Akira
1978-08-01
For high accuracy observation of multiple-body reactions, a vertex detector of high efficiency is essential. A bubble chamber, though excellent for tracks detection, is problematic in statistics accuracy. The vertex detector with a wire chamber, while better in this respect, difficult in multiple-particle detection etc. The workshop has had several meetings on a streamer chamber as a detector combining features of both bubble chamber and counter, with emphasis on tracks observation in avalanche mode and recordings not using films. Contents are on streamer chamber gas, analytical photography, data processing, simulation program, etc. (Mori, K.)
Kansal, Rohit; Talwar, Sangeeta; Yadav, Seema; Chaudhary, Sarika; Nawal, Ruchika
2014-01-01
The preparation of the root canal system is essential for a successful outcome in root canal treatment. The development of rotary nickel titanium instruments is considered to be an important innovation in the field of endodontics. During few last years, several new instrument systems have been introduced but the quest for simplifying the endodontic instrumentation sequence has been ongoing for almost 20 years, resulting in more than 70 different engine-driven endodontic instrumentation system...
International Nuclear Information System (INIS)
Manero Amoros, F.
1962-01-01
In the present paper the working principles of a gridded ionization chamber are given, and all the different factors that determine its resolution power are analyzed in detail. One of these devices, built in the Physics Division of the JEN and designed specially for use in measurements of alpha spectroscopy, is described. finally the main applications, in which the chamber can be used, are shown. (Author) 17 refs
Peterson, D; Briere, R A; Chen, G; Cronin-Hennessy, D; Csorna, S; Dickson, M; Dombrowski, S V; Ecklund, K M; Lyon, A; Marka, S; Meyer, T O; Patterson, J R; Sadoff, A; Thies, P; Thorndike, E H; Urner, D
2002-01-01
The CLEO group at the Cornell Electron Storage Ring has constructed and commissioned a new central drift chamber. With 9796 cells arranged in 47 layers ranging in radius from 13.2 to 79 cm, the new drift chamber has a smaller outer radius and fewer wires than the drift chamber it replaces, but allows the CLEO tracking system to have improved momentum resolution. Reduced scattering material in the chamber gas and in the inner skin separating the drift chamber from the silicon vertex detector provides a reduction of the multiple scattering component of the momentum resolution and an extension of the usable measurement length into the silicon. Momentum resolution is further improved through quality control in wire positioning and symmetry of the electric fields in the drift cells which have provided a reduction in the spatial resolution to 88 mu m (averaged over the full drift range).
Energy Technology Data Exchange (ETDEWEB)
Destaillats, Hugo; Lunden, Melissa M.; Singer, Brett C.; Coleman,Beverly K.; Hodgson, Alfred T.; Weschler, Charles J.; Nazaroff, William W.
2005-10-01
Ozone-driven chemistry is a major source of indoor secondary pollutants of health concern. This study investigates secondary air pollutants formed from reactions between constituents of household products and ozone. Gas-phase product emissions were introduced along with ozone at constant rates into a 198-L Teflon-lined reaction chamber. Gas-phase concentrations of reactive terpenoids and oxidation products were measured. Formaldehyde was a predominant oxidation byproduct for the three studied products, with yields under most conditions of 20-30% with respect to ozone consumed. Acetaldehyde, acetone, glycolaldehyde, formic acid and acetic acid were each also detected for two or three of the products. Immediately upon mixing of reactants, a scanning mobility particle sizer detected particle nucleation events that were followed by a significant degree of ultrafine particle growth. The production of secondary gaseous pollutants and particles depended primarily on the ozone level and was influenced by other parameters such as the air-exchange rate. Hydroxyl radical concentrations in the range 0.04-200 x 10{sup 5} molecules cm{sup -3} were measured. OH concentrations were observed to vary strongly with residual ozone level in the chamber, which was in the range 1-25 ppb, as is consistent with expectations from a simplified kinetic model. In a separate test, we exposed the dry residue of two products to ozone in the chamber and observed the formation of gas-phase and particle-phase secondary oxidation products.
OPAL was one of the four experiments installed at the LEP particle accelerator from 1989 - 2000. OPAL's central tracking system consists of (in order of increasing radius) a silicon microvertex detector, a vertex detector, a jet chamber, and z-chambers. All the tracking detectors work by observing the ionization of atoms by charged particles passing by: when the atoms are ionized, electrons are knocked out of their atomic orbitals, and are then able to move freely in the detector. These ionization electrons are detected in the dirfferent parts of the tracking system. This piece is a prototype of the jet chambers
International Nuclear Information System (INIS)
Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki
1998-01-01
Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)
Siahaan, S.; Homma, H.; Homma, H.
2018-02-01
Energy crisis and global warming, in other words, climate change are critical topics discussed in various parts of the world. Global warming primarily result from too much emission of carbon dioxide (CO2) in the atmosphere. To mitigate global warming, or climate change and improve electrification in rural areas, wood pyrolysis technology is developed in a laboratory scale, of which gases are directly applicable to the gas engine generator. Our laboratory has developed a prototype of wood pyrolysis plant with a pre-vacuum chamber. However, tar yield was around 40 wt% of feedstock. This research aims to reduce tar yield by secondary tar cracking. For the secondary tar cracking, a secondary pre-vacuum chamber is installed after primary pre-vacuum chamber. Gases generated in the primary pre-vacuum chamber are lead into the secondary chamber that is heated up to 1000 K. This paper reports performance of the secondary chamber for secondary tar cracking in homogeneous mode and heterogeneous mode with char.
An Integration of MICROMEGAS Based Muon Tracking Chambers in ALICE
Cussonneau, J P; CERN. Geneva
1999-01-01
A global solution for the muon tracking chambers of ALICE based on the detector MICROMEGAS [1], is investigated at SUBATECH. A technical design of the structures of the MICROMEGAS modules is presented as well as their assemblies in individual chamber and their final integration in the five tracking stations required for the muon spectrometer. The whole concept is based on only 3 kinds of MICROMEGAS units. Within these stand-alone modules, the 2D location is achieved by taking advantage of charge division with resistive strips. Including the support frames for the mosaic of detectors, the average station thickness will stay below 3% of Xo. The whole electronics features about 1.3 106 channels. Preliminary considerations on the MICROMEGAS FEE and its on-board integration are discussed. A first estimation of the total cost of this option stays well inside the assigned budget of the technical proposal.
Additive Manufacturing of Low Cost Upper Stage Propulsion Components
Protz, Christopher; Bowman, Randy; Cooper, Ken; Fikes, John; Taminger, Karen; Wright, Belinda
2014-01-01
NASA is currently developing Additive Manufacturing (AM) technologies and design tools aimed at reducing the costs and manufacturing time of regeneratively cooled rocket engine components. These Low Cost Upper Stage Propulsion (LCUSP) tasks are funded through NASA's Game Changing Development Program in the Space Technology Mission Directorate. The LCUSP project will develop a copper alloy additive manufacturing design process and develop and optimize the Electron Beam Freeform Fabrication (EBF3) manufacturing process to direct deposit a nickel alloy structural jacket and manifolds onto an SLM manufactured GRCop chamber and Ni-alloy nozzle. In order to develop these processes, the project will characterize both the microstructural and mechanical properties of the SLMproduced GRCop-84, and will explore and document novel design techniques specific to AM combustion devices components. These manufacturing technologies will be used to build a 25K-class regenerative chamber and nozzle (to be used with tested DMLS injectors) that will be tested individually and as a system in hot fire tests to demonstrate the applicability of the technologies. These tasks are expected to bring costs and manufacturing time down as spacecraft propulsion systems typically comprise more than 70% of the total vehicle cost and account for a significant portion of the development schedule. Additionally, high pressure/high temperature combustion chambers and nozzles must be regeneratively cooled to survive their operating environment, causing their design to be time consuming and costly to build. LCUSP presents an opportunity to develop and demonstrate a process that can infuse these technologies into industry, build competition, and drive down costs of future engines.
Utilization of handheld computing to simplify compliance
International Nuclear Information System (INIS)
Galvin, G.; Rasmussen, J.; Haines, A.
2008-01-01
Monitoring job site performance and building a continually improving organization is an ongoing challenge for operators of process and power generation facilities. Stakeholders need to accurately capture records of quality and safety compliance, job progress, and operational experiences (OPEX). This paper explores the use of technology-enabled processes as a means for simplifying compliance to quality, safety, administrative, maintenance and operations activities. The discussion will explore a number of emerging technologies and their application to simplifying task execution and process compliance. This paper will further discuss methodologies to further refine processes through trending improvements in compliance and continually optimizing and simplifying through the use of technology. (author)
Proportional chamber with data analog output
International Nuclear Information System (INIS)
Popov, V.E.; Prokof'ev, A.N.
1977-01-01
A proportional multiwier chamber is described. The chamber makes it possible to determine angles at wich a pion strikes a polarized target. A delay line, made of 60-core flat cable is used for removing signals from the chamber. From the delay line, signals are amplified and successively injected into shapers and a time-to-amplitude converter. An amplitude of the time-to amplitude converter output signal unambiguously determines the coordinate of a point at which a particle strikes the chamber plane. There are also given circuits of amplifiers, which consist of a preamplifier with gain 30 and a main amplifier with adjustable gain. Data on testing the chamber with the 450 MeV pion beam is demonstrated. The chamber features an efficiency of about 98 per cent under load of 2x10 5 s -1
CP Methods for Scheduling and Routing with Time-Dependent Task Costs
DEFF Research Database (Denmark)
Tierney, Kevin; Kelareva, Elena; Kilby, Philip
2013-01-01
a cost function, and Mixed Integer Programming (MIP) are often used for solving such problems. However, Constraint Programming (CP), particularly with Lazy Clause Genera- tion (LCG), has been found to be faster than MIP for some scheduling problems with time-varying action costs. In this paper, we...... compare CP and LCG against a solve-and-improve approach for two recently introduced problems in maritime logistics with time-varying action costs: the Liner Shipping Fleet Repositioning Problem (LSFRP) and the Bulk Port Cargo Throughput Optimisation Problem (BPCTOP). We present a novel CP model...... for the LSFRP, which is faster than all previous methods and outperforms a simplified automated planning model without time-varying costs. We show that a LCG solver is faster for solving the BPCTOP than a standard finite domain CP solver with a simplified model. We find that CP and LCG are effective methods...
Silent Politics – How local chambers of commerce in the Philippines fail to foster democratisation
Directory of Open Access Journals (Sweden)
Basanta, Thapa
2015-09-01
Full Text Available Philippine democratic consolidation stagnates despite a vibrant civil society. A comparative exploration of three local chambers of commerce in the Visayas and Mindanao reveals that, contrary to established typologies, it is the decidedly non-confrontational stance towards government that keeps the chambers as civil society actors from contributing to democratic consolidation. Further, it becomes apparent that working within the existing clientelistic political structures is the most efficient strategy for interest groups to achieve political goals, while publicly confrontational strategies, which may be most conducive to democratic consolidation, can result in heavy political and economic costs.
Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
Design and fabrication of a chamber for the deposit of thin films by laser ablation
International Nuclear Information System (INIS)
Chirino O, S.; Escobar A, I.; Camps C, E.; Garcia E, J.I.
2000-01-01
The laser ablation technique is an alternative for the obtention of thin films which is less expensive, more reliable, efficient and with some advantages with respect to conventional processes. On of the most important components which forms a laser ablation system is the vacuum chamber, that has as general purposes the following: a) To carry out studies about plasma such as optical emission spectroscopy and measurements by deflectometry. b) To carry out an In situ monitoring about the film growth through the reflectivity measurements of the combination substrate-film. c) To deposit thin films of different materials such as oxides, carbon, metals, etc. In this work it is showed how the vacuum chamber was designed and made to perform the store of thin films by laser ablation and for characterising the formed plasma as a result of the ablation process. The chamber design was enough versatile that will allow to add it more accessory just making it simple modifications. Its cost was very cheap more or less one twentieth of a commercial chamber. (Author)
Proton beam monitor chamber calibration
International Nuclear Information System (INIS)
Gomà, C; Meer, D; Safai, S; Lorentini, S
2014-01-01
The first goal of this paper is to clarify the reference conditions for the reference dosimetry of clinical proton beams. A clear distinction is made between proton beam delivery systems which should be calibrated with a spread-out Bragg peak field and those that should be calibrated with a (pseudo-)monoenergetic proton beam. For the latter, this paper also compares two independent dosimetry techniques to calibrate the beam monitor chambers: absolute dosimetry (of the number of protons exiting the nozzle) with a Faraday cup and reference dosimetry (i.e. determination of the absorbed dose to water under IAEA TRS-398 reference conditions) with an ionization chamber. To compare the two techniques, Monte Carlo simulations were performed to convert dose-to-water to proton fluence. A good agreement was found between the Faraday cup technique and the reference dosimetry with a plane-parallel ionization chamber. The differences—of the order of 3%—were found to be within the uncertainty of the comparison. For cylindrical ionization chambers, however, the agreement was only possible when positioning the effective point of measurement of the chamber at the reference measurement depth—i.e. not complying with IAEA TRS-398 recommendations. In conclusion, for cylindrical ionization chambers, IAEA TRS-398 reference conditions for monoenergetic proton beams led to a systematic error in the determination of the absorbed dose to water, especially relevant for low-energy proton beams. To overcome this problem, the effective point of measurement of cylindrical ionization chambers should be taken into account when positioning the reference point of the chamber. Within the current IAEA TRS-398 recommendations, it seems advisable to use plane-parallel ionization chambers—rather than cylindrical chambers—for the reference dosimetry of pseudo-monoenergetic proton beams. (paper)
Gentry, James; Rango, Juan; Zhang, Jianzhong; Biedermann, Shane
2017-04-01
Decompression sickness (DCS) is a potential danger and risk for both divers and aircrew alike. DCS is also a potential side effect of altitude (hypobaric) chamber training as well and can present long after training occurs. Literature review shows that altitude chamber induced DCS has approximately a 0.25% incidence. A 32-yr-old, active duty military member developed symptoms of DCS 3 h after his hypobaric chamber training. Unfortunately, he did not seek treatment for DCS until 48 h after the exposure. His initial treatment included ground level oxygen therapy for 30 min at 12 L of oxygen per minute using a nonrebreathing mask. He achieved complete symptom resolution and was returned to duty. However, 12 d after his initial Flight Medicine evaluation, the patient returned complaining of a right temporal headache, multijoint pains, and fatigue. He was treated in the hyperbaric chamber and had complete resolution of symptoms. He was returned to flying status and 5 mo later denied any return of symptoms. Hypobaric chamber familiarity training is a requirement for all military aircrew personnel to allow them assess their ability to identify symptoms of hypoxia. This training method is not only costly to maintain, but it also places aircrew and chamber technicians at risk for potential long-term side effects from failed recompression treatment of DCS. We are presenting a case of recurrent DCS symptoms 12 d after initial ground level oxygen therapy.Gentry J, Rango J, Zhang J, Biedermann S. Latent presentation of decompression sickness after altitude chamber training in an active duty flier. Aerosp Med Hum Perform. 2017; 88(4):427-430.
Pressure vessel rupture within a chamber: the pressure history on the chamber wall
International Nuclear Information System (INIS)
Baum, M.R.
1989-04-01
Generally there is a large number of pressure vessels containing high pressure gas on power stations and chemical plant. In many instances, particularly on power plant, these vessels are within the main building. If a pressure vessel were to fail, the surrounding structures would be exposed to blast loads and the forces resulting from jets of fluid issuing from the breached vessel. In the case where the vessel is in a relatively closed chamber there would also be a general overpressurisation of the chamber. At the design stage it is therefore essential to demonstrate that the plant could be safely shut down in the event of a pressure vessel failure, that is, it must be shown that the chamber will not collapse thus putting the building at risk or hazarding equipment essential for a safe shut down. Such an assessment requires the loads applied to the chamber walls, roof, etc. to be known. (author)
Low-cost satellite mechanical design and construction
Boisjolie-Gair, Nathaniel; Straub, Jeremy
2017-05-01
This paper presents a discussion of techniques for low-cost design and construction of a CubeSat mechanical structure that can serve as a basis for academic programs and a starting point for government, military and commercial large-scale sensing networks, where the cost of each node must be minimized to facilitate system affordability and lower the cost and associated risk of losing any node. Spacecraft Design plays a large role in manufacturability. An intentionally simplified mechanical design is presented which reduces machining costs, as compared to more intricate designs that were considered. Several fabrication approaches are evaluated relative to the low-cost goal.
Wet drift chambers for precise luminosity
International Nuclear Information System (INIS)
Anderson, B.E.; Kennedy, B.W.; Ahmet, K.; Attree, D.J.; Barraclough, G.A.; Cresswell, M.J.; Hayes, D.A.; Miller, D.J.; Selby, C.; Sherwood, P.
1994-01-01
A set of high-precision compact drift chambers has been a vital component of the OPAL luminosity monitor since the start of data-taking at LEP. They were augmented in 1992 by the addition of Small Angle Reference Chambers with a very similar design to the original chamber. The performance of the chambers is reviewed, highlighting both the importance of using polyalkylene glycol (Breox) to maintain a uniform and parallel electric field and the construction techniques used to sustain the required field strength. We describe some of the operating problems, with their solutions, and show how the chambers have been used in achieving a systematic error of 0.41% on the luminosity measurement. ((orig.))
The Boycott effect in magma chambers
Blanchette, F.; Peacock, T.; Bush, J. W. M.
2004-03-01
We investigate the plausibility of the stratified Boycott effect as a source of layering in magma chambers. Crystal settling within the magma chamber will generate buoyant fluid near the sloping sidewalls whose vertical ascent may be limited by the ambient stratification associated with vertical gradients in SiO2. The resulting flow may be marked by a layered structure, each layer taking the form of a convection cell spanning the lateral extent of the magma chamber. Using parameters relevant to magma chambers, we estimate that such convection cells would be established over a timescale of a month and have a depth on the order of 4m, which is roughly consistent with field observations of strata within solidified chambers.
The KEK 1 m hydrogen bubble chamber
International Nuclear Information System (INIS)
Doi, Yoshikuni; Araoka, Osamu; Hayashi, Kohei; Hayashi, Yoshio; Hirabayashi, Hiromi.
1978-03-01
A medium size hydrogen bubble chamber has been constructed at the National Laboratory for High Energy Physics, KEK. The bubble chamber has been designed to be operated with a maximum rate of three times per half a second in every two second repetition time of the accelerator, by utilizing a hydraulic expansion system. The bubble chamber has a one meter diameter and a visible volume of about 280 l. A three-view stereo camera system is used for taking photographic pictures of the chamber. A 2 MW bubble chamber magnet is constructed. The main part of the bubble chamber vessel is supported by the magnet yoke. The magnet gives a maximum field of 18.4 kG at the centre of the fiducial volume of the chamber. The overall system of the KEK 1 m hydrogen bubble chamber facility is described in some detail. Some operational characteristics of the facility are also reported. (auth.)
48 CFR 1552.232-74 - Payments-simplified acquisition procedures financing.
2010-10-01
... acquisition procedures financing. 1552.232-74 Section 1552.232-74 Federal Acquisition Regulations System... Provisions and Clauses 1552.232-74 Payments—simplified acquisition procedures financing. As prescribed in... acquisition procedures financing. Payments—Simplified Acquisition Procedures Financing (JUN 2006) Simplified...
Loss of ions in cavity ionization chambers
International Nuclear Information System (INIS)
Takata, N.; Tran, N.T.; Kim, E.; Marsoem, P.; Kurosawa, T.; Koyama, Y.
2005-01-01
Ion losses due to initial recombination, volume recombination, and back diffusion were each determined by measurements and calculations for different size cylindrical ionization chambers and spherical ionization chambers. By measuring signal currents from these ionization chambers irradiated with 60 Co gamma rays, two groups of ion losses were obtained. (Group 1) Ion loss due to initial recombination and diffusion, which changes proportionally to the inverse of the voltage applied to the ionization chambers; (and group 2) ion loss due to volume recombination, which changes proportionally to the inverse of the square of the applied voltage. The diffusion loss was obtained separately by computing electric field distributions in the ionization chambers. It was found that diffusion loss is larger than initial recombination loss for the cylindrical ionization chambers and vise versa for the spherical ionization chambers
Investigation of very long jet chambers
Energy Technology Data Exchange (ETDEWEB)
Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P
1986-04-01
The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP.
Simplified analysis of laterally loaded pile groups
Directory of Open Access Journals (Sweden)
F.M. Abdrabbo
2012-06-01
Full Text Available The response of laterally loaded pile groups is a complicated soil–structure interaction problem. Although fairly reliable methods are developed to predicate the lateral behavior of single piles, the lateral response of pile groups has attracted less attention due to the required high cost and complication implication. This study presents a simplified method to analyze laterally loaded pile groups. The proposed method implements p-multiplier factors in combination with the horizontal modulus of subgrade reaction. Shadowing effects in closely spaced piles in a group were taken into consideration. It is proven that laterally loaded piles embedded in sand can be analyzed within the working load range assuming a linear relationship between lateral load and lateral displacement. The proposed method estimates the distribution of lateral loads among piles in a pile group and predicts the safe design lateral load of a pile group. The benefit of the proposed method is in its simplicity for the preliminary design stage with a little computational effort.
Impedances in lossy elliptical vacuum chambers
International Nuclear Information System (INIS)
Piwinski, A.
1994-04-01
The wake fields of a bunched beam caused by the resistivity of the chamber walls are investigated for a vacuum chamber with elliptical cross section. The longitudinal and transverse impedances are calculated for arbitrary energies and for an arbitrary position of the beam in the chamber. (orig.)
Process-Improvement Cost Model for the Emergency Department.
Dyas, Sheila R; Greenfield, Eric; Messimer, Sherri; Thotakura, Swati; Gholston, Sampson; Doughty, Tracy; Hays, Mary; Ivey, Richard; Spalding, Joseph; Phillips, Robin
2015-01-01
The objective of this report is to present a simplified, activity-based costing approach for hospital emergency departments (EDs) to use with Lean Six Sigma cost-benefit analyses. The cost model complexity is reduced by removing diagnostic and condition-specific costs, thereby revealing the underlying process activities' cost inefficiencies. Examples are provided for evaluating the cost savings from reducing discharge delays and the cost impact of keeping patients in the ED (boarding) after the decision to admit has been made. The process-improvement cost model provides a needed tool in selecting, prioritizing, and validating Lean process-improvement projects in the ED and other areas of patient care that involve multiple dissimilar diagnoses.
Renewal processes with costs and rewards
Vlasiou, M.; Cochran, J.J.; Cox, L.A.; Keskinocak, P.; Kharoufeh, J.P.; Smith, J.C.
2011-01-01
We review the theory of renewal reward processes, which describes renewal processes that have some cost or reward associated with each cycle. We present a new simplified proof of the renewal reward theorem that mimics the proof of the Elementary Renewal Theorem and avoids the technicalities in the
Simplified method evaluation for piping elastic follow-up
International Nuclear Information System (INIS)
Severud, L.K.
1983-05-01
A proposed simplified method for evaluating elastic follow-up effects in high temperature pipelines is presented. The method was evaluated by comparing the simplified analysis results with those obtained from detailed inelastic solutions. Nine different pipelines typical of a nuclear breeder reactor power plant were analyzed; the simplified method is attractive because it appears to give fairly accurate and conservative results. It is easy to apply and inexpensive since it employs iterative elastic solutions for the pipeline coupled with the readily available isochronous stress-strain data provided in the ASME Code
Investigation of very long jet chambers
Energy Technology Data Exchange (ETDEWEB)
Burckhart, H J; Va' vra, J; Zankel, K; Dudziak, U; Schaile, D; Schaile, O; Igo-Kemenes, P; Lennert, P
1986-04-01
The electrostatic properties and the performances of very long jet chambers have been investigated. Using 100 MHz FADC wave form digitisers, the tracking accuracy, the charge division and the dE/dx performance of two chambers, one with 4.5 m long tungsten wires and one with 4 m long highly resistive ''NiCoTi'' wires have been studied. The geometry of the chambers was chosen to define some of the design parameters of the jet chamber for the OPAL detector for LEP. (orig.).
A New Rapid Simplified Model for Urban Rainstorm Inundation with Low Data Requirements
Directory of Open Access Journals (Sweden)
Ji Shen
2016-11-01
Full Text Available This paper proposes a new rapid simplified inundation model (NRSIM for flood inundation caused by rainstorms in an urban setting that can simulate the urban rainstorm inundation extent and depth in a data-scarce area. Drainage basins delineated from a floodplain map according to the distribution of the inundation sources serve as the calculation cells of NRSIM. To reduce data requirements and computational costs of the model, the internal topography of each calculation cell is simplified to a circular cone, and a mass conservation equation based on a volume spreading algorithm is established to simulate the interior water filling process. Moreover, an improved D8 algorithm is outlined for the simulation of water spilling between different cells. The performance of NRSIM is evaluated by comparing the simulated results with those from a traditional rapid flood spreading model (TRFSM for various resolutions of digital elevation model (DEM data. The results are as follows: (1 given high-resolution DEM data input, the TRFSM model has better performance in terms of precision than NRSIM; (2 the results from TRFSM are seriously affected by the decrease in DEM data resolution, whereas those from NRSIM are not; and (3 NRSIM always requires less computational time than TRFSM. Apparently, compared with the complex hydrodynamic or traditional rapid flood spreading model, NRSIM has much better applicability and cost-efficiency in real-time urban inundation forecasting for data-sparse areas.
An innovative system for supplying air and fuel mixture to a combustion chamber of an engine
Saikumar, G. R. Bharath
2018-04-01
Conventional carburetors are being used since decades to ensure that the desired ratio of air and fuel enters the combustion chamber for combustion for the purpose of generating power in an Spark Ignition(SI) internal combustion engine. However to increase the efficiency, the carburetor system is gradually being replaced by fuel injection systems. Fuel injection systems use injectors to supply pressurized fuel into the combustion chamber. Owing to the high initial and maintenance cost, carburetors are still ruling in the low cost vehicle domain. An innovative concept is conceived, which is an alternative method to the carburetor system to supply the air and fuel mixture to a combustion chamber of an engine. This system comprises of an inner hollow cylinder with minute holes drilled along its length with an outer cylinder capable of sliding along its length or its longitudinal axis. This system is placed in the venturi instead of the conventional carburetor system. Fuel enters from the bottom inlet of the inner cylinder and flows out through the holes provided along its length. The fuel flow from the inner cylinder is dependent on the size and the number of holes exposed at that instance by the sliding outer cylinder which in turn is connected to the throttle or accelerator.
International Nuclear Information System (INIS)
Zhao Pingde; Xu Zhiqing; Tang Xiaowei
1986-01-01
The characteristics of multiwire proportional chamber and multistage avalanche chamber filled with argon and photoionization gas (C 2 H 5 ) 3 N were measured. The spatial resolution curves and output pulse height spectra were measured as well. Low concentration (C 2 H 5 ) 3 N can play an effective part in quenching. At very low concentration, the phenomena of avalanche transverse expansion was observed obviously
PEP quark search proportional chambers
Energy Technology Data Exchange (ETDEWEB)
Parker, S I; Harris, F; Karliner, I; Yount, D [Hawaii Univ., Honolulu (USA); Ely, R; Hamilton, R; Pun, T [California Univ., Berkeley (USA). Lawrence Berkeley Lab.; Guryn, W; Miller, D; Fries, R [Northwestern Univ., Evanston, IL (USA)
1981-04-01
Proportional chambers are used in the PEP Free Quark Search to identify and remove possible background sources such as particles traversing the edges of counters, to permit geometric corrections to the dE/dx and TOF information from the scintillator and Cerenkov counters, and to look for possible high cross section quarks. The present beam pipe has a thickness of 0.007 interaction lengths (lambdasub(i)) and is followed in both arms each with 45/sup 0/ <= theta <= 135/sup 0/, ..delta..phi=90/sup 0/ by 5 proportional chambers, each 0.0008 lambdasub(i) thick with 32 channels of pulse height readout, and by 3 thin scintillator planes, each 0.003 lambdasub(i) thick. Following this thin front end, each arm of the detector has 8 layers of scintillator (one with scintillating light pipes) interspersed with 4 proportional chambers and a layer of lucite Cerenkov counters. Both the calculated ion statistics and measurements using He-CH/sub 4/ gas in a test chamber indicate that the chamber efficiencies should be >98% for q=1/3. The Landau spread measured in the test was equal to that observed for normal q=1 traversals. One scintillator plane and thin chamber in each arm will have an extra set of ADC's with a wide gate bracketing the normal one so timing errors and tails of earlier pulses should not produce fake quarks.
International Nuclear Information System (INIS)
Rienecker, F. Jr.; Glaros, S.S.; Kobierecki, M.
1975-01-01
A target chamber for application in the laser fusion program must satisfy some very basic requirements. (1) Provide a vacuum on the order of 10 -6 torr. (2) Support a microscopically small target in a fixed point in space and verify its location within 5 micrometers. (3) Contain an adjustable beam focusing system capable of delivering a number of laser beams onto the target simultaneously, both in time and space. (4) Provide access for diagnostics to evaluate the results of target irradiation. (5) Have flexibility to allow changes in targets, focusing optics and number of beams. The ARGUS laser which is now under construction at LLL will have a target chamber which meets these requirements in a simple economic manner. The chamber and auxiliary equipment are described, with reference to two double beam focusing systems; namely, lenses and ellipsoidal mirrors. Provision is made for future operation with four beams, using ellipsoidal mirrors for two-sided illumination and lens systems for tetragonal and tetrahedral irradiation
Generic simplified simulation model for DFIG with active crowbar
Energy Technology Data Exchange (ETDEWEB)
Buendia, Francisco Jimenez [Gamesa Innovation and Technology, Sarriguren, Navarra (Spain). Technology Dept.; Barrasa Gordo, Borja [Assystem Iberia, Bilbao, Vizcaya (Spain)
2012-07-01
Simplified models for transient stability studies are a general requirement for transmission system operators to wind turbine (WTG) manufacturers. Those models must represent the performance of the WTGs for transient stability studies, mainly voltage dips originated by short circuits in the electrical network. Those models are implemented in simulation software as PSS/E, DigSilent or PSLF. Those software platforms allow simulation of transients in large electrical networks with thousands of busses, generators and loads. The high complexity of the grid requires that the models inserted into the grid should be simplified in order to allow the simulations being executed as fast as possible. The development of a model which is simplified enough to be integrated in those complex grids and represent the performance of WTG is a challenge. The IEC TC88 working group has developed generic models for different types of generators, among others for WTGs using doubly fed induction generators (DFIG). This paper will focus in an extension of the models for DFIG WTGs developed in IEC in order to be able to represent the simplified model of DFIG with an active crowbar, which is required to withstand voltage dips without disconnecting from the grid. This paper improves current generic model of Type 3 for DFIG adding a simplified version of the generator including crowbar functionality and a simplified version of the crowbar firing. In addition, this simplified model is validated by correlation with voltage dip field test from a real wind turbine. (orig.)
Morgante, Enrico
2018-01-01
I review the construction of Simplified Models for Dark Matter searches. After discussing the philosophy and some simple examples, I turn the attention to the aspect of the theoretical consistency and to the implications of the necessary extensions of these models.
Cylindrical ionization chamber with compressed krypton
International Nuclear Information System (INIS)
Kuz'minov, V.V.; Novikov, V.M.; Pomanskii, A.A.; Pritychenko, B.V.; Viyar, J.; Garcia, E.; Morales, A.; Morales, J.; Nunes-Lagos, R.; Puimedon, J.; Saens, K.; Salinas, A.; Sarsa, M.
1993-01-01
A cylindrical ionization chamber with a grid is used to search for double positron decay and atomic electron conversion to a positron in 78 Kr. Krypton is the working gas material of the chamber. The spectrometric characteristics of the chamber filled with krypton and xenon are presented. The energy resolution is 2.1% for an energy of 1.84 MeV (the source of γ-quanta is 88 Y) when the chamber is filled with a mixture of Kr+0.2% H 2 under a pressure of 25 atm
Hypersonic Vehicle Propulsion System Simplified Model Development
Stueber, Thomas J.; Raitano, Paul; Le, Dzu K.; Ouzts, Peter
2007-01-01
This document addresses the modeling task plan for the hypersonic GN&C GRC team members. The overall propulsion system modeling task plan is a multi-step process and the task plan identified in this document addresses the first steps (short term modeling goals). The procedures and tools produced from this effort will be useful for creating simplified dynamic models applicable to a hypersonic vehicle propulsion system. The document continues with the GRC short term modeling goal. Next, a general description of the desired simplified model is presented along with simulations that are available to varying degrees. The simulations may be available in electronic form (FORTRAN, CFD, MatLab,...) or in paper form in published documents. Finally, roadmaps outlining possible avenues towards realizing simplified model are presented.
Advances on fission chamber modelling
International Nuclear Information System (INIS)
Filliatre, Philippe; Jammes, Christian; Geslot, Benoit; Veenhof, Rob
2013-06-01
In-vessel, online neutron flux measurements are routinely performed in mock-up and material testing reactors by fission chambers. Those measurements have a wide range of applications, including characterization of experimental conditions, reactor monitoring and safety. Depending on the application, detectors may experience a wide range of constraints, of several magnitudes, in term of neutron flux, gamma-ray flux, temperature. Hence, designing a specific fission chamber and measuring chain for a given application is a demanding task. It can be achieved by a combination of experimental feedback and simulating tools, the latter being based on a comprehensive understanding of the underlying physics. A computation route that simulates fission chambers, named CHESTER, is presented. The retrieved quantities of interest are the neutron-induced charge spectrum, the electronic and ionic pulses, the mean current and variance, the power spectrum. It relies on the GARFIELD suite, originally developed for drift chambers, and makes use of the MAGBOLTZ code to assess the drift parameters of electrons within the filling gas, and the SRIM code to evaluate the stopping range of fission products. The effect of the gamma flux is also estimated. Computations made with several fission chambers exemplify the possibilities of the route. A good qualitative agreement is obtained when comparing the results with the experimental data available to date. In a near future, a comprehensive experimental programme will be undertaken to qualify the route using the known neutron sources, mock-up reactors and wide choice of fission chambers, with a stress on the predictiveness of the Campbelling mode. Depending on the results, a refinement of the modelling and an effort on the accuracy of input data are also to be considered. CHESTER will then make it possible to predict the overall sensitivity of a chamber, and to optimize the design for a given application. Another benefit will be to increase the
An electrodeless drift chamber
International Nuclear Information System (INIS)
Allison, J.; Barlow, R.J.; Bowdery, C.K.; Duerdoth, I.; Rowe, P.G.
1982-01-01
We describe a chamber in which the drift field is controlled by the deposition of electrostatic charge on an insulating surface. The chamber operates with good efficiency and precision for observed drift distances of up to 45 cm, promises to be extremely robust and adaptable and offers a very cheap way of making particle detectors. (orig.)
DELPHI time projection chamber
1989-01-01
The time projection chamber is inserted inside the central detector of the DELPHI experiment. Gas is ionised in the chamber as a charged particle passes through, producing an electric signal from which the path of the particle can be found. DELPHI, which ran from 1989 to 2000 on the LEP accelerator, was primarily concerned with particle identification.
Kutkut, Ahmad; Abu-Hammad, Osama; Frazer, Robert
2016-01-01
Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations. PMID:29563457
Directory of Open Access Journals (Sweden)
Ahmad Kutkut
2016-05-01
Full Text Available Impression techniques for implant restorations can be implant level or abutment level impressions with open tray or closed tray techniques. Conventional implant-abutment level impression techniques are predictable for maximizing esthetic outcomes. Restoration of the implant traditionally requires the use of the metal or plastic impression copings, analogs, and laboratory components. Simplifying the dental implant restoration by reducing armamentarium through incorporating conventional techniques used daily for crowns and bridges will allow more general dentists to restore implants in their practices. The demonstrated technique is useful when modifications to implant abutments are required to correct the angulation of malpositioned implants. This technique utilizes conventional crown and bridge impression techniques. As an added benefit, it reduces costs by utilizing techniques used daily for crowns and bridges. The aim of this report is to describe a simplified conventional impression technique for custom abutments and modified prefabricated solid abutments for definitive restorations.
48 CFR 3032.003 - Simplified acquisition procedures financing.
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Simplified acquisition procedures financing. 3032.003 Section 3032.003 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND... FINANCING Scope of Part 3032.003 Simplified acquisition procedures financing. Contract financing may be...
International Nuclear Information System (INIS)
Mariaud, C.
2012-01-01
The cloud chamber had its heyday in the first half of last century and allowed the discovery of new particles such as the anti-electron, the muon and the neutral and the charged kaon. The bubble chamber replaced it in the mid fifties. This article recalls the principle of the cloud chamber and shows, in a detailed way, how to proceed to build one with on-the-shelf materials. This design is based on the use of isopropanol whose liquefaction through the form of droplets materializes the track of the particle and on the use of combined Peltier cells (instead of CO 2 snow) to cool the chamber. This cloud chamber has been successfully used in schools to observe particles mainly electrons, alphas and muons generated by cosmic rays. (A.C.)
A mathematical model of aerosol holding chambers
DEFF Research Database (Denmark)
Zak, M; Madsen, J; Berg, E
1999-01-01
A mathematical model of aerosol delivery from holding chambers (spacers) was developed incorporating tidal volume (VT), chamber volume (Vch), apparatus dead space (VD), effect of valve insufficiency and other leaks, loss of aerosol by immediate impact on the chamber wall, and fallout of aerosol...... in the chamber with time. Four different spacers were connected via filters to a mechanical lung model, and aerosol delivery during "breathing" was determined from drug recovery from the filters. The formula correctly predicted the delivery of budesonide aerosol from the AeroChamber (Trudell Medical, London...
Simplified Occupancy Grid Indoor Mapping Optimized for Low-Cost Robots
Directory of Open Access Journals (Sweden)
Javier Garrido
2013-10-01
Full Text Available This paper presents a mapping system that is suitable for small mobile robots. An ad hoc algorithm for mapping based on the Occupancy Grid method has been developed. The algorithm includes some simplifications in order to be used with low-cost hardware resources. The proposed mapping system has been built in order to be completely autonomous and unassisted. The proposal has been tested with a mobile robot that uses infrared sensors to measure distances to obstacles and uses an ultrasonic beacon system for localization, besides wheel encoders. Finally, experimental results are presented.
Quality control of ATLAS muon chambers
Fabich, Adrian
ATLAS is a general-purpose experiment for the future Large Hadron Collider (LHC) at CERN. Its Muon Spectrometer will require ∼ 5500m2 of precision tracking chambers to measure the muon tracks along a spectrometer arm of 5m to 15m length, embedded in a magnetic field of ∼ 0.5T. The precision tracking devices in the Muon System will be high pressure drift tubes (MDTs). Approximately 370,000 MDTs will be assembled into ∼ 1200 drift chambers. The performance of the MDT chambers is very much dependent on the mechanical quality of the chambers. The uniformity and stability of the performance can only be assured providing very high quality control during production. Gas tightness, high-voltage behaviour and dark currents are global parameters which are common to gas detectors. For all chambers, they will be tested immediately after the chamber assembly at every production site. Functional tests, for example radioactive source scans and cosmic-ray runs, will be performed in order to establish detailed performan...
Hyperbaric and hypobaric chamber fires: a 73-year analysis.
Sheffield, P J; Desautels, D A
1997-09-01
Fire can be catastrophic in the confined space of a hyperbaric chamber. From 1923 to 1996, 77 human fatalities occurred in 35 hyperbaric chamber fires, three human fatalities in a pressurized Apollo Command Module, and two human fatalities in three hypobaric chamber fires reported in Asia, Europe, and North America. Two fires occurred in diving bells, eight occurred in recompression (or decompression) chambers, and 25 occurred in clinical hyperbaric chambers. No fire fatalities were reported in the clinical hyperbaric chambers of North America. Chamber fires before 1980 were principally caused by electrical ignition. Since 1980, chamber fires have been primarily caused by prohibited sources of ignition that an occupant carried inside the chamber. Each fatal chamber fire has occurred in an enriched oxygen atmosphere (> 28% oxygen) and in the presence of abundant burnable material. Chambers pressurized with air (Hyperbaric Medical Society's Chamber Experience and Mishap Database. This epidemiologic review focuses on information learned from critical analyses of chamber fires and how it can be applied to safe operation of hypobaric and hyperbaric chambers.
HVAC&R Equipment Environmental Chambers
Federal Laboratory Consortium — Description:Large "Truck" ChamberThe large "truck" chamber provides controlled air conditions from -7 °C (20 °F) to 65 °C (150 °F).Air-Conditioner and Heat Pump Test...
Flame retardation of cellulose-rich fabrics via a simplified layer-by-layer assembly.
Yang, Jun-Chi; Liao, Wang; Deng, Shi-Bi; Cao, Zhi-Jie; Wang, Yu-Zhong
2016-10-20
Due to the high cellulose content of cotton (88.0-96.5%), the flame retardation of cotton fabrics can be achieved via an approach for the flame retardation of cellulose. In this work, a facile water-based flame retardant coating was deposited on cotton fabrics by a 'simplified' layer-by-layer (LbL) assembly. The novel coating solution was based on a mild reaction between ammonium polyphosphate (APP) and branched polyethyleneimine (BPEI), and the reaction mechanism was studied. TGA results showed that the char residues of coated fabrics were remarkably increased. The fabric with only 5wt% coating showed self-extinguishing in the horizontal flame test, and the peak heat release rate (pHRR) in cone calorimeter test decreased by 51%. Furthermore, this coating overcame a general drawback of flame-retardant LbL assembly which was easily washed away. Therefore, the simplified LbL method provides a fast, low-cost, eco-friendly and wash-durable flame-retardant finishing for the cellulose-rich cotton fabrics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Micro plate fission chamber development
International Nuclear Information System (INIS)
Wang Mei; Wen Zhongwei; Lin Jufang; Jiang Li; Liu Rong; Wang Dalun
2014-01-01
To conduct the measurement of neutron flux and the fission rate distribution at several position in assemblies, the micro plate fission chamber was designed and fabricated. Since the requirement of smaller volume and less structure material was taken into consideration, it is convinient, commercial and practical to use fission chamber to measure neutron flux in specific condition. In this paper, the structure of fission chamber and process of fabrication were introduced and performance test result was presented. The detection efficiency is 91.7%. (authors)
Ionization chamber for smoke detector and the like
International Nuclear Information System (INIS)
Rork, G.D.; Thorp, E.J.; Zegarski, R.J.
1985-01-01
This invention relates to detectors of the ionization type for detecting airborne particulate matter and, in particular, to the construction of an ionization chamber for such a detector. This invention may be used for detecting a variety of materials, such as dust, fog and the like, but is particularly useful for detecting combustion products such as smoke. The smoke detector ionization chamber has two electrodes connected to a source of electric power; means defining access openings for enabling air flow into and out of the chamber; and means for causing ionization within the chamber. It has control structure means within the chamber in the path of the airflow cooperating with the electrodes to establish within the chamber an electric field having a higher intensity close to the access openings and a lower intensity in the remainder of the chamber without significantly impairing the flow of neutral particles into the chamber. The control structure reduces airflow velocity within the chamber without adversely affecting the access of airborne particles to the chamber
Energy Technology Data Exchange (ETDEWEB)
Meier, W R
2011-02-24
The key feature of liquid wall chambers is the use of a renewable liquid layer to protect chamber structures from target emissions. Two primary options have been proposed and studied: wetted wall chambers and thick liquid wall (TLW) chambers. With wetted wall designs, a thin layer of liquid shields the structural first wall from short ranged target emissions (x-rays, ions and debris) but not neutrons. Various schemes have been proposed to establish and renew the liquid layer between shots including flow-guiding porous fabrics (e.g., Osiris, HIBALL), porous rigid structures (Prometheus) and thin film flows (KOYO). The thin liquid layer can be the tritium breeding material (e.g., flibe, PbLi, or Li) or another liquid metal such as Pb. TLWs use liquid jets injected by stationary or oscillating nozzles to form a neutronically thick layer (typically with an effective thickness of {approx}50 cm) of liquid between the target and first structural wall. In addition to absorbing short ranged emissions, the thick liquid layer degrades the neutron flux and energy reaching the first wall, typically by {approx}10 x x, so that steel walls can survive for the life of the plant ({approx}30-60 yrs). The thick liquid serves as the primary coolant and tritium breeding material (most recent designs use flibe, but the earliest concepts used Li). In essence, the TLW places the fusion blanket inside the first wall instead of behind the first wall.
Screening efficacy of a simplified logMAR chart
Directory of Open Access Journals (Sweden)
Naganathan Muthuramalingam
2016-04-01
Aim: This study evaluates the efficacy of a simplified logMAR chart, designed for VA testing over the conventional Snellen chart, in a school-based vision-screening programme. Methods: We designed a simplified logMAR chart by employing the principles of the Early Treatment Diabetic Retinopathy Study (ETDRS chart in terms of logarithmic letter size progression, inter-letter spacing, and inter-line spacing. Once the simplified logMAR chart was validated by students in the Elite school vision-screening programme, we set out to test the chart in 88 primary and middle schools in the Tiruporur block of Kancheepuram district in Tamil Nadu. One school teacher in each school was trained to screen a cross-sectional population of 10 354 primary and secondary school children (girls: 5488; boys: 4866 for VA deficits using a new, simplified logMAR algorithm. An experienced paediatric optometrist was recruited to validate the screening methods and technique used by the teachers to collect the data. Results: The optometrist screened a subset of 1300 school children from the total sample. The optometrist provided the professional insights needed to validate the clinical efficacy of the simplified logMAR algorithm and verified the reliability of the data collected by the teachers. The mean age of children sampled for validation was 8.6 years (range: 9–14 years. The sensitivity and the specificity of the simplified logMAR chart when compared to the standard logMAR chart were found to be 95% and 98%, respectively. Kappa value was 0.97. Sensitivity of the teachers’ screening was 66.63% (95% confidence interval [CI]: 52.73–77.02 and the specificity was 98.33% (95% CI: 97.49–98.95. Testing of VA was done under substandard illumination levels in 87% of the population. A total of 10 354 children were screened, 425 of whom were found to have some form of visual and/or ocular defect that was identified by the teacher or optometrist. Conclusion: The simplified logMAR testing algorithm
Energy Technology Data Exchange (ETDEWEB)
Ravet, F. [Rouen Univ., 76 - Mont-Saint-Aignan (France)]|[SNECMA, 77 - Moissy-Cramayel (France); Baudoin, Ch.; Schultz, J.L. [SNECMA, 77 - Moissy-Cramayel (France)
1996-12-31
Simplifying hypotheses are required when combustion and aerodynamic phenomena are considered simultaneously. In this paper, a turbulent combustion model is proposed, in which the combustion chemistry is reduced to a single reaction. In this way, only two variables are needed to describe the problem and combustion can be characterized by the consumption of one of the two reactive species. In a first step, the instantaneous consumption rate is obtained using the Lagrangian form of the mass fraction equation of the species under consideration, and by considering the equilibrium state only. This state is determined in order to preserve the consistency with results that should be obtained using a complete kinetics scheme. In a second step, the average rate is determined using the instantaneous consumption term and a probabilistic density function. This model was tested on various configurations and in particular on an experimental main chamber and on a reheating chamber. Results indicate that this model could be used to predict temperature levels inside these combustion chambers. Other applications, like the prediction of pollutant species emission can be considered. (J.S.) 12 refs.
Bayesian models for cost-effectiveness analysis in the presence of structural zero costs.
Baio, Gianluca
2014-05-20
Bayesian modelling for cost-effectiveness data has received much attention in both the health economics and the statistical literature, in recent years. Cost-effectiveness data are characterised by a relatively complex structure of relationships linking a suitable measure of clinical benefit (e.g. quality-adjusted life years) and the associated costs. Simplifying assumptions, such as (bivariate) normality of the underlying distributions, are usually not granted, particularly for the cost variable, which is characterised by markedly skewed distributions. In addition, individual-level data sets are often characterised by the presence of structural zeros in the cost variable. Hurdle models can be used to account for the presence of excess zeros in a distribution and have been applied in the context of cost data. We extend their application to cost-effectiveness data, defining a full Bayesian specification, which consists of a model for the individual probability of null costs, a marginal model for the costs and a conditional model for the measure of effectiveness (given the observed costs). We presented the model using a working example to describe its main features. © 2013 The Authors. Statistics in Medicine published by John Wiley & Sons, Ltd.
High resolution drift chambers
International Nuclear Information System (INIS)
Va'vra, J.
1985-07-01
High precision drift chambers capable of achieving less than or equal to 50 μm resolutions are discussed. In particular, we compare so called cool and hot gases, various charge collection geometries, several timing techniques and we also discuss some systematic problems. We also present what we would consider an ''ultimate'' design of the vertex chamber. 50 refs., 36 figs., 6 tabs
The Mark II Vertex Drift Chamber
International Nuclear Information System (INIS)
Alexander, J.P.; Baggs, R.; Fujino, D.
1989-03-01
We have completed constructing and begun operating the Mark II Drift Chamber Vertex Detector. The chamber, based on a modified jet cell design, achieves 30 μm spatial resolution and 2 gas mixtures. Special emphasis has been placed on controlling systematic errors including the use of novel construction techniques which permit accurate wire placement. Chamber performance has been studied with cosmic ray tracks collected with the chamber located both inside and outside the Mark II. Results on spatial resolution, average pulse shape, and some properties of CO 2 mixtures are presented. 10 refs., 12 figs., 1 tab
Bicone vacuum chamber for ISR intersection
1975-01-01
This is one of the bicone chambers made of titanium for experiment R 702. The central corrugated part had a very thin titanium wall (0.28 mm). The first of these chambers collapsed in its central part when baked at 300 C (August 1975). After an intensive effort to develop better quality and reproducible welds for this special material, the ISR workshop was able to build two new chambers of this type. One of them was installed at I 7 for R 702 in 1976 and worked perfectly. It was at that time the most "transparent" intersection vacuum chamber. See also 7609219, 7609221.
International Nuclear Information System (INIS)
Arai, Y.; Funahashi, Y.; Higashi, Y.
1992-04-01
We propose a jet-type drift chamber for the barrel and intermediate muon detectors of SDC. The chamber system consists of large multiwire drift chambers having a simple box-type frame structure: 2. 5 x 0.4 m 2 in cross section and maximum 9 m in length. A chamber module consists of double layers of small jet cells. The drift cell is composed of a wire plane, including 3 sense wires, and cathode plates parallel to the wire plane. The two layers in a chamber are staggered to each other by half a cell width. The jet cell is tilted such that its principle axis points to the interaction point. Such an arrangement, together with a constant drift velocity of the jet cell, allows us to design a simple and powerful trigger system for high momentum muons utilizing a drift time sum between a pair of staggered cells. The multi-hit capability will be helpful to distinguish high momentum muon tracks from associated electromagnetic debris as has been demonstrated by the Fermilab beam test T816. The maximum drift time fulfills the SDC requirement. A preliminary FEM analysis of the chamber module verified the excellent structural stiffness. It makes the support structure and the alignment system relatively simple. These features will reduce the total cost as well as ensure a good performance of the chamber system. (J.P.N.)
Simplified design of switching power supplies
Lenk, John
1995-01-01
* Describes the operation of each circuit in detail * Examines a wide selection of external components that modify the IC package characteristics * Provides hands-on, essential information for designing a switching power supply Simplified Design of Switching Power Supplies is an all-inclusive, one-stop guide to switching power-supply design. Step-by-step instructions and diagrams render this book essential for the student and the experimenter, as well as the design professional. Simplified Design of Switching Power Supplies concentrates on the use of IC regulators. All popular forms of swit
Energy Technology Data Exchange (ETDEWEB)
Queralt, R. (Junta de Saneamientos. Generalidad de Catalua (Spain))
1993-03-01
The calculation of the investment involved in purifying industrial waste water poses certain problems since this is affected either by employing complicated methods which require a great deal of data or, as the sole alternative, through subjective estimates. The present article purposes an intermediate system based on simplified formulas for which it is only necessary to know three parameters, namely, (in the majority of cases) the industrial activity, the flow and the Q.O.D. (Author)
Growing and analyzing biofilms in flow chambers
DEFF Research Database (Denmark)
Tolker-Nielsen, Tim; Sternberg, Claus
2011-01-01
This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber-grown biofilms are addressed....
Comparison among different CT ionization chambers
International Nuclear Information System (INIS)
Castro, Maysa C. de; Xavier, Marcos; Caldas, Linda V.E.
2015-01-01
The dosimetry in computed tomography (CT) is carried out by the use of a pencil type ionization-chamber, because it has a uniform response at all angles relative to the incident beam of radiation, which is essential for CT equipment since the X-ray tube executes a circular movement around the table during irradiation. The commercial ionization chamber used to perform quality control procedures of this kind of equipment has a length of the sensitive volume of 10 cm. In the Calibration Laboratory of Instruments (LCI) of the IPEN there were already developed some prototypes with small differences in construction, when compared to commercially available ionization chambers. They have been used in previous studies and showed results within internationally acceptable limits. The ionization chambers tested in this study present the sensitive volume lengths of 1 cm, 3 cm and 10 cm. The objective of this study was to present results on the stability test of the three homemade ionization chambers and a commercial chamber, as well to obtain the calibration coefficients for each of them in CT standard X radiation beams. The obtained results for both characterization tests are within the recommended limits, except for the homemade ionization chambers with sensitive volume lengths of 3 cm and 1 cm in the case of the stability test. (author)
Temperature distribution of a simplified rotor due to a uniform heat source
Welzenbach, Sarah; Fischer, Tim; Meier, Felix; Werner, Ewald; kyzy, Sonun Ulan; Munz, Oliver
2018-03-01
In gas turbines, high combustion efficiency as well as operational safety are required. Thus, labyrinth seal systems with honeycomb liners are commonly used. In the case of rubbing events in the seal system, the components can be damaged due to cyclic thermal and mechanical loads. Temperature differences occurring at labyrinth seal fins during rubbing events can be determined by considering a single heat source acting periodically on the surface of a rotating cylinder. Existing literature analysing the temperature distribution on rotating cylindrical bodies due to a stationary heat source is reviewed. The temperature distribution on the circumference of a simplified labyrinth seal fin is calculated using an available and easy to implement analytical approach. A finite element model of the simplified labyrinth seal fin is created and the numerical results are compared to the analytical results. The temperature distributions calculated by the analytical and the numerical approaches coincide for low sliding velocities, while there are discrepancies of the calculated maximum temperatures for higher sliding velocities. The use of the analytical approach allows the conservative estimation of the maximum temperatures arising in labyrinth seal fins during rubbing events. At the same time, high calculation costs can be avoided.
Multi-chamber actuated micro-dispensing with a single nozzle for sub-nanoliter droplet formation
International Nuclear Information System (INIS)
Song, Sukho; Kim, Sangjin; Kim, Changsung Sean; Kang, Philjoong; Ku, Bosung
2014-01-01
A novel concept of single-nozzle micro-dispensing device with multiple pressurizing chambers is proposed for high-throughput drug screening applications such as arraying new drug candidates with sub-nanoliter volume. The theoretical study with a simplified electrical circuit model of the fluidic system shows that the proposed model is effective to sustain jetting stability at high frequency due to an increase in the natural frequency of the fluidic system and high attenuation of the negative pressure wave in the fluidic system. The fabricated device was able to form uniform droplets at up to 7 kHz having 115 pL (1.15 × 10 −10 L) in volume and 1.8 m s −1 ∼ 2.5 m s −1 in velocity. (paper)
Yeo, Lami; Romero, Roberto; Jodicke, Cristiano; Oggè, Giovanna; Lee, Wesley; Kusanovic, Juan Pedro; Vaisbuch, Edi; Hassan, Sonia S.
2010-01-01
view and/or long axis view of the aorta, four-chamber view, and stomach in 100% of normal cases. In the abnormal cases, the FAST Echo algorithm demonstrated the cardiac defects and displayed views that deviated from what was expected from the examination of normal hearts. The “swing technique” was useful in demonstrating the specific diagnosis due to visualization of an infinite number of cardiac planes in sequence. Conclusions This novel and simple algorithm can be used to visualize standard fetal echocardiographic planes in normal fetal hearts. The FAST Echo algorithm may simplify examination of the fetal heart and could reduce operator dependency. Using this algorithm, the inability to obtain expected views or the appearance of abnormal views in the generated planes should raise the index of suspicion for congenital heart disease. PMID:20878671
Yeo, L; Romero, R; Jodicke, C; Oggè, G; Lee, W; Kusanovic, J P; Vaisbuch, E; Hassan, S
2011-04-01
-axis view of the aorta, four-chamber view and stomach in 100% of normal cases. In the abnormal cases, the FAST echo algorithm demonstrated the cardiac defects and displayed views that deviated from what was expected from the examination of normal hearts. The swing technique was useful for demonstrating the specific diagnosis due to visualization of an infinite number of cardiac planes in sequence. This novel and simple algorithm can be used to visualize standard fetal echocardiographic planes in normal fetal hearts. The FAST echo algorithm may simplify examination of the fetal heart and could reduce operator dependency. Using this algorithm, inability to obtain expected views or the appearance of abnormal views in the generated planes should raise the index of suspicion for congenital heart disease. Copyright © 2011 ISUOG. Published by John Wiley & Sons, Ltd.
45 CFR 1630.3 - Standards governing allowability of costs under Corporation grants or contracts.
2010-10-01
... services to low-income clients, allocation of indirect costs may be by a simplified allocation method... accordance with the relative benefits received. Costs may be allocated to Corporation funds either as direct... necessary to the overall operation of the recipient, although a direct relationship to any particular cost...
Development of cattleya amethystoglossa x nobilior - orquidaceae in simplified culture media
Directory of Open Access Journals (Sweden)
Murilo Goulart Berka
2014-08-01
Full Text Available Three simplified, low-cost culture media, prepared with foliar fertilizers, were compared with the commonly used ½ MS-ban (Murashige Skoog medium ½ salt concentration, with banana fruit for the in vitro multiplication of the orchid hybrid Cattleya amethystoglossa x nobilior. The simplified culture media tested were Hy-ban, which is made with 1.33 g L-1 of Hyponex fertilizer (NPK 6.5-6-19; KP-ban, which is made with 0.92 g L-1 of Kristalon™ (NPK 6-12-36 and 0.26 g L-1 of Peters (NPK 30-10-10; and Kcal-ban, which is made with 0.92 g L-1 of Kristalon™ (NPK 6-12-36 and 0.51 g L-1 of Calcinit (NPK 15.5-0-0+Ca 19.0%. Each medium was supplemented with 20 g L-1 of sucrose, 1 g L-1 of activated charcoal, 7 g L-1 of agar-agar and 40 g L-1 of banana fruit, pH 5.6. Plantlets were evaluated after 80 days for the following parameters: number of shoots, shoot length, number of roots, longest root length and fresh weight. While all four media can be used for the studied hybrid, the best medium was Kcal-ban.
Rapid and sustained cost management
International Nuclear Information System (INIS)
Hanson, D.
2009-01-01
Accenture helps clients develop comprehensive, process-driven strategies for rapid and sustained cost management that leverage deep insights and analytics. This approach enables companies to gain operating cost advantages by rationalizing, simplifying and automating current operating capabilities. It drives structural cost advantages by optimizing business mix, capital structure, organizational structure and geographic presence. This paper discussed how successful companies achieve high performance during times of economic turmoil. It also discussed the value of the winner's strategy in terms of rapid and sustained cost management (RSCM). It discussed how Accenture operates and its leveraged capabilities, improved efficiency, margins and cash flow while maintaining customer service levels. Building structural advantage and the Accenture difference were also discussed. It was concluded that RSCM is one vital way that Accenture can help companies achieve success. 4 figs
Energy Technology Data Exchange (ETDEWEB)
Kydonieos, M; Folgueras, A; Florescu, L; Cybulski, T; Marinos, N; Thompson, G; Sayeed, A [Elekta Limited, Crawley, West Sussex (United Kingdom); Rozendaal, R; Olaciregui-Ruiz, I [Netherlands Cancer Institute - Antoni van Leeuwenhoek, Amsterdam, Noord-Holland (Netherlands); Subiel, A; Patallo, I Silvestre [National Physical Laboratory, London (United Kingdom)
2016-06-15
Purpose: Elekta recently developed a solution for in-vivo EPID dosimetry (iViewDose, Elekta AB, Stockholm, Sweden) in conjunction with the Netherlands Cancer Institute (NKI). This uses a simplified commissioning approach via Template Commissioning Models (TCMs), consisting of a subset of linac-independent pre-defined parameters. This work compares the performance of iViewDose using a TCM commissioning approach with that corresponding to full commissioning. Additionally, the dose reconstruction based on the simplified commissioning approach is validated via independent dose measurements. Methods: Measurements were performed at the NKI on a VersaHD™ (Elekta AB, Stockholm, Sweden). Treatment plans were generated with Pinnacle 9.8 (Philips Medical Systems, Eindhoven, The Netherlands). A farmer chamber dose measurement and two EPID images were used to create a linac-specific commissioning model based on a TCM. A complete set of commissioning measurements was collected and a full commissioning model was created.The performance of iViewDose based on the two commissioning approaches was compared via a series of set-to-work tests in a slab phantom. In these tests, iViewDose reconstructs and compares EPID to TPS dose for square fields, IMRT and VMAT plans via global gamma analysis and isocentre dose difference. A clinical VMAT plan was delivered to a homogeneous Octavius 4D phantom (PTW, Freiburg, Germany). Dose was measured with the Octavius 1500 array and VeriSoft software was used for 3D dose reconstruction. EPID images were acquired. TCM-based iViewDose and 3D Octavius dose distributions were compared against the TPS. Results: For both the TCM-based and the full commissioning approaches, the pass rate, mean γ and dose difference were >97%, <0.5 and <2.5%, respectively. Equivalent gamma analysis results were obtained for iViewDose (TCM approach) and Octavius for a VMAT plan. Conclusion: iViewDose produces similar results with the simplified and full commissioning
International Nuclear Information System (INIS)
Pavicevic, M.
1963-07-01
This second volume of the project for construction of the protection chamber in the RA reactor hall for handling the radioactive devices includes the technical description of the chamber, calculation of the shielding wall thickness, bottom lead plate, horizontal stability of the chamber, cost estimation, and the engineering drawings
Multi-stage low-pressure avalanche chamber
International Nuclear Information System (INIS)
Zanevskij, Yu.V.; Peshekhonov, V.D.; Smykov, L.P.
1985-01-01
A multi-stage avalanche-chamber filled with isobutane operating at the pressure of 6 torr is described. The chamber comprises an amplifying gap, drift gap and multiwire proportional chamber with interelectrode gaps equal to 4 mm. The anode plane of the proportional chamber is winded of wire 2 μm in diameter with 2 mm pitch. The cathode are winded orthogonally to anode wires of wire 50 μm in diameter with 1 mm pitch. Drift and preamplifier gaps are formed by grid electrodes made of wire 50 μm in diameter with dimension of the cell equal to 1x1 mm. Width of the drift gap is 5 mm, width of the preamplification gap is 3 or 9 mm. Coordinate data are removed from the cathodes of the proportional chamber by means of delay lines. Sensitive square of the chamber equals 240x180 mm. Gas gain coefficient is 3x10 6 at its square nonuniformity equal to approximately 3%. Spatial resolution by both coordinates equals 170 μm; spatial resolution for isotropic α-emitters located close to the preamplifier gap is equal to 500 μm
International Nuclear Information System (INIS)
Logan, G.B.; Moir, R.W.; Hoffmman, M.A.
1995-01-01
The economy of scale for multiunit inertial fusion energy (IFE) power plants is explored based on the molten salt HYLIFE-II fusion chamber concept, for the purpose of producing lower cost electricity and hydrogen fuel. The cost of electricity (CoE) is minimized with a new IFE systems code IFEFUEL5 for a matrix of plant cases with one to eight fusion chambers of 250 to 2000-MW (electric) net output each, sharing a common heavy-ion driver and target factory. Improvements to previous HYLIFE-II models include a recirculating induction linac driver optimized as a function of driver energy and rep-rate (average driver power), inclusion of beam switchyard costs, a fusion chamber cost scaling dependence on both thermal power and fusion yield, and a more accurate bypass pump power scaling with chamber rep-rate. A CoE less than 3 cents/kW(electric)-h is found for plant outputs greater than 2 GW(electric), allowing hydrogen fuel production by wafer electrolysis to provide lower fuel cost per mile for higher efficiency hydrogen engines compared with gasoline engines. These multiunit, multi-GW(electric) IFE plants allow staged utility plant deployment, lower optimum chamber rep-rates, less sensitivity to driver and target fabrication costs, and a CoE possibly lower than future fission, fossil, and solar competitors. 37 refs., 12 figs., 4 tabs
Monitored Drift Chambers in the ATLAS Detector
Herten, G
Monitored Drift Chambers (MDT) are used in the ATLAS Detector to measure the momentum of high energy muons. They consist of drift tubes, which are filled with an Ar-CO2 gas mixture at 3 bar gas pressure. About 1200 drift chambers are required for ATLAS. They are up to 6 m long. Nevertheless the position of every wire needs to be known with a precision of 20 µm within a chamber. In addition, optical alignment sensors are required to measure the relative position of adjacent chambers with a precision of 30µm. This gigantic task seems impossible at first instance. Indeed it took many years of R&D to invent the right tools and methods before the first chamber could be built according to specifications. Today, at the time when 50% of the chambers have been produced, we are confident that the goal for ATLAS can be reached. The mechanical precision of the chambers could be verified with the x-ray tomograph at CERN. This ingenious device, developed for the MDT system, is able to measure the wire position insid...
International Nuclear Information System (INIS)
Constans, H.; Coville, P.; Guerre, J.
1975-01-01
Reactor control requires the determination of neutron flux at all times. The needed characteristics lead to use of several types of detectors: boron lined counters, boron lined ionization chambers, fission ionization chambers and self powered detectors. The principle of the reaction involved the fabrication requirements, the different modes of utilization and the characteristics obtained are examined for each detector. The problem of electric connections in the active area has been solved by developing ''integrated cables'' [fr
Parametric cost analysis of a HYLIFE-II power plant
International Nuclear Information System (INIS)
Bieri, R.L.
1991-01-01
The SAFIRE (Systems Analysis for ICF Reactor Economics) code was adapted to model a power plant using a HYLIFE-2 reactor chamber. The code was then used to examine the dependence of the plant capital costs and the busbar cost of electricity (COE) on a variety of design parameters (type of driver, chamber repetition rate, and net electric power). The results show the most attractive operating space for each set of driver/target assumptions and quantify the benefits of improvements in key design parameters. The base-case plant was a 1000-MW(e) plant containing a reactor vessel driven by an induction linac heavy-ion accelerator, run at 8 Hz with a driver energy of 6.73 MJ and a target yield of 350 MJ. The total direct cost for this plant was $2.6 billion. (All costs in this paper are given in equivalent 1988 dollars.) The COE was 8.5 cents/(kWh). The COE and total capital costs for a 1000-MW(e) base plant are nearly independent of the chosen combination of repetition rate and driver energy for a driver operating between 4 and 10 Hz. For comparison, the COE for a coal or future fission plant would be 4.5--5.5 cents/(kWh). The COE for a 1000-MW(e) plant could be reduced to 7.5 cents/(kWh) by using advanced targets and could be cut to 6.5 cents/(kWh) with conventional targets, if the driver cost could be cut in half. There is a large economy of scale with heavy-ion-driven inertial confinement fusion (ICF) plants. A 2000-MW(e) plant with a heavy-ion driver and a HYLIFE-2 chamber would have a COE of only 5.8 cents/(kWh)
AECB Cost Recovery Fees Regulations, amendment
International Nuclear Information System (INIS)
1992-01-01
The amendments to the AECB Cost Recovery Fees Regulations have been made with a view to simplifying the registration procedure for obtaining such a certificate or approval under the above Transport Regulations. In effect there will no longer be a need for a separate fee system for registered users of certified package designs. (NEA)
The little holographic bubble chambers
International Nuclear Information System (INIS)
Herve, A.
1983-01-01
The lifetime study of the charmed particles has readvanced the idea to use holography for the little fast-cycle bubble chambers. A pilot experiment has been realised in 1982 with a little bubble chamber filled up with freon-115. 40000 holograms have been recorded [fr
Pelletron general purpose scattering chamber
International Nuclear Information System (INIS)
Chatterjee, A.; Kailas, S.; Kerekette, S.S.; Navin, A.; Kumar, Suresh
1993-01-01
A medium sized stainless steel scattering chamber has been constructed for nuclear scattering and reaction experiments at the 14UD pelletron accelerator facility. It has been so designed that several types of detectors, varying from small sized silicon surface barrier detectors to medium sized gas detectors and NaI detectors can be conveniently positioned inside the chamber for detection of charged particles. The chamber has been planned to perform the following types of experiments : angular distributions of elastically scattered particles, fission fragments and other charged particles, angular correlations for charged particles e.g. protons, alphas and fission fragments. (author). 2 figs
International Nuclear Information System (INIS)
Pretzsch, G.; Boerner, E.; Lehmann, R.; Sarenio, O.
1986-01-01
The invention relates to the detection of radioactive gases emitting alpha particles like radon, thoron and their alpha-decaying daughters by means of a diffusion chamber with a passive detector, preferably with a solid state track detector. In the chamber above and towards the detector there is a single metallized electret with negative polarity. The distance between electret and detector corresponds to the range of the alpha particles of radon daughters in air at the most. The electret collects the positively charged daughters and functions as surface source. The electret increases the sensitivity by the factor 4
Multispecimen dual-beam irradiation damage chamber
International Nuclear Information System (INIS)
Packan, N.H.; Buhl, R.A.
1980-06-01
An irradiation damage chamber that can be used to rapidly simulate fast neutron damage in fission or fusion materials has been designed and constructed. The chamber operates in conjunction with dual Van de Graaff accelerators at ORNL to simulate a wide range of irradiation conditions, including pulsed irradiation. Up to six experiments, each with up to nine 3-mm disk specimens, can be loaded into the ultrahigh vacuum chamber. Specimen holders are heated with individual electron guns, and the temperature of each specimen can be monitored during bombardment by an infrared pyrometer. Three different dose levels may be obtained during any single bombardment, and the heavy-ion flux on each of the nine specimens can be measured independently with only a brief interruption of the beam. The chamber has been in service for nearly three years, during which time approximately 250 bombardments have been successfully carried out. An appendix contains detailed procedures for operating the chamber
Bi-cone vacuum chamber in the ISR
CERN PhotoLab
1976-01-01
The "bi-cone" vacuum chamber in ISR intersection I-7, for experiment R702. Made from 0.28 mm thick titanium, it was at its time the most transparent chamber ever built. Ian Wilson is standing next to the chamber. See also 7609219.
Device for gamma-chamber transducer alignment
International Nuclear Information System (INIS)
Mirkhodzhaev, A.Kh.; Kuznetsov, N.K.; Ostryj, Yu.E.
1987-01-01
The device consists of the upper part of the gamma chamber pilar to which a rod is rigidly fastened with a disk of acrylic plastic moving freely on the opposite end. The disk is placed coaxially and is equal to the gamma chamber detector crystal. The device makes it possible to use ordinary medical couches covered with a porolone mattress when the gamma chamber detector is placed below
Bubble chamber: Omega production and decay
1973-01-01
This image is taken from one of CERN's bubble chambers and shows the decay of a positive kaon in flight. The decay products of this kaon can be seen spiraling in the magnetic field of the chamber. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that has been heated to boiling point.
Apparatus for reading and recharging condenser ionization chambers
International Nuclear Information System (INIS)
McCall, R.C.
1977-01-01
A metering circuit for a condenser ionization chamber is disclosed for simultaneously recharging the ionization chamber and reading out the amount of charge required to recharge the chamber. During the recharging process, the amount of charge necessary to recharge the ionization chamber capacitor is placed on an integrating capacitor in the metering apparatus. The resultant voltage across the integrating capacitor is a measure of the radiation to which the ionization chamber was exposed. 9 claims, 1 figure
Liquid-filled ionization chamber temperature dependence
Energy Technology Data Exchange (ETDEWEB)
Franco, L. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)]. E-mail: luciaff@usc.es; Gomez, F. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Iglesias, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pardo, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pazos, A. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Pena, J. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain); Zapata, M. [Dpto. de Fisica de Particulas, Facultade de Fisica, Universidade de Santiago, Campus Sur S/N, 15782 Santiago de Compostela (Spain)
2006-05-10
Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a {approx}20 deg. C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27x10{sup -2}K{sup -1} for an operation electric field of 1.67x10{sup 6}Vm{sup -1} has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.
Usefulness of hemocytometer as a counting chamber in a computer assisted sperm analyzer (CASA)
Eljarah, A.; Chandler, J.; Jenkins, J.A.; Chenevert, J.; Alcanal, A.
2013-01-01
Several methods are used to determine sperm cell concentration, such as the haemocytometer, spectrophotometer, electronic cell counter and computer-assisted semen analysers (CASA). The utility of CASA systems has been limited due to the lack of characterization of individual systems and the absence of standardization among laboratories. The aims of this study were to: 1) validate and establish setup conditions for the CASA system utilizing the haemocytometer as a counting chamber, and 2) compare the different methods used for the determination of sperm cell concentration in bull semen. Two ejaculates were collected and the sperm cell concentration was determined using spectrophotometer and haemocytometer. For the Hamilton-Thorn method, the haemocytometer was used as a counting chamber. Sperm concentration was determined three times per ejaculate samples. A difference (P 0.05) or between the haemocytometer count and the spectrophotometer. Based on the results of this study, we concluded that the haemocytometer can be used in computerized semen analysis systems as a substitute for the commercially available disposable counting chambers, therefore avoiding disadvantageous high costs and slower procedures.
Cost effectiveness of dilute chemical decontamination
International Nuclear Information System (INIS)
LeSurf, J.E.; Weyman, G.D.
The basic principles of dilute chemical decontamination are described, as well as the method of application. Methods of computing savings in radiation dose and costs are presented, with results from actual experience and illustrative examples. It is concluded that dilute chemical decontamination is beneficial in many cases. It reduces radiation exposure of workers, saves money, and simplifies maintenance work
Bubble chamber: antiproton annihilation
1971-01-01
These images show real particle tracks from the annihilation of an antiproton in the 80 cm Saclay liquid hydrogen bubble chamber. A negative kaon and a neutral kaon are produced in this process, as well as a positive pion. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.
Simplified Dynamic Analysis of Grinders Spindle Node
Demec, Peter
2014-12-01
The contribution deals with the simplified dynamic analysis of surface grinding machine spindle node. Dynamic analysis is based on the use of the transfer matrix method, which is essentially a matrix form of method of initial parameters. The advantage of the described method, despite the seemingly complex mathematical apparatus, is primarily, that it does not require for solve the problem of costly commercial software using finite element method. All calculations can be made for example in MS Excel, which is advantageous especially in the initial stages of constructing of spindle node for the rapid assessment of the suitability its design. After detailing the entire structure of spindle node is then also necessary to perform the refined dynamic analysis in the environment of FEM, which it requires the necessary skills and experience and it is therefore economically difficult. This work was developed within grant project KEGA No. 023TUKE-4/2012 Creation of a comprehensive educational - teaching material for the article Production technique using a combination of traditional and modern information technology and e-learning.
Setting limits on supersymmetry using simplified models
Gutschow, C.
2012-01-01
Experimental limits on supersymmetry and similar theories are difficult to set because of the enormous available parameter space and difficult to generalize because of the complexity of single points. Therefore, more phenomenological, simplified models are becoming popular for setting experimental limits, as they have clearer physical implications. The use of these simplified model limits to set a real limit on a concrete theory has not, however, been demonstrated. This paper recasts simplified model limits into limits on a specific and complete supersymmetry model, minimal supergravity. Limits obtained under various physical assumptions are comparable to those produced by directed searches. A prescription is provided for calculating conservative and aggressive limits on additional theories. Using acceptance and efficiency tables along with the expected and observed numbers of events in various signal regions, LHC experimental results can be re-cast in this manner into almost any theoretical framework, includ...
Development of long operating cycle simplified BWR
International Nuclear Information System (INIS)
Heki, H.; Nakamaru, M.; Maruya, T.; Hiraiwa, K.; Arai, K.; Narabayash, T.; Aritomi, M.
2002-01-01
This paper describes an innovative plant concept for long operating cycle simplified BWR (LSBWR) In this plant concept, 1) Long operating cycle ( 3 to 15 years), 2) Simplified systems and building, 3) Factory fabrication in module are discussed. Designing long operating core is based on medium enriched U-235 with burnable poison. Simplified systems and building are realized by using natural circulation with bottom located core, internal CRD and PCV with passive system and an integrated reactor and turbine building. This LSBWR concept will have make high degree of safety by IVR (In Vessel Retention) capability, large water inventory above the core region and no PCV vent to the environment due to PCCS (Passive Containment Cooling System) and internal vent tank. Integrated building concept could realize highly modular arrangement in hull structure (ship frame structure), ease of seismic isolation capability and high applicability of standardization and factory fabrication. (authors)
Temperature Studies for ATLAS MDT BOS Chambers
Engl, A.; Biebel, O.; Mameghani, R.; Merkl, D.; Rauscher, F.; Schaile, D.; Ströhmer, R.
Data sets with high statistics taken at the cosmic ray facility, equipped with 3 ATLAS BOS MDT chambers, in Garching (Munich) have been used to study temperature and pressure effects on gas gain and drifttime. The deformation of a thermally expanded chamber was reconstructed using the internal RasNik alignment monitoring system and the tracks from cosmic data. For these studies a heating system was designed to increase the temperature of the middle chamber by up to 20 Kelvins over room temperature. For comparison the temperature effects on gas properties have been simulated with Garfield. The maximum drifttime decreased under temperature raise by -2.21 +- 0.08 ns/K, in agreement with the results of pressure variations and the Garfield simulation. The increased temperatures led to a linear increase of the gas gain of about 2.1% 1/K. The chamber deformation has been analyzed with the help of reconstructed tracks. By the comparison of the tracks through the reference chambers with these through the test chamber ...
Brookhaven National Laboratory's multiparticle spectrometer drift chamber system
International Nuclear Information System (INIS)
Etkin, A.; Kramer, M.A.
1979-01-01
A system of drift chambers is being built to replace the present spark chambers in the Brookhaven National Laboratory's Multiparticle Spectrometer. This system will handle a beam of approx. 3 million particles per second and have a resolution of 200 μm. A summary of the status of the chambers and the custom integrated circuits is presented. The data acquisition system is described. Prototype chambers have been built and tested with results that are consistent with the expected chamber properties
Researching the Performance of Dual-Chamber Fire-Tube Boiler Furnace
Directory of Open Access Journals (Sweden)
Khaustov Sergei
2015-01-01
Full Text Available Autonomous heating systems equipped with fire-tube or shell boilers show high effectiveness, consistent performance and great technical parameters. But there is a significant limitation of its thermal productivity due to the complexity of durable large diameter fire-tube bottoms implementation. Optimization of combustion aerodynamics can be the way to expand the fire-tube boilers performance limit. In this case lots of problems connected with reducing emissions of toxic substances, providing of burning stability, local heat stresses and aerodynamic resistances should be solved. To resolve the indicated problems, a modified model of dual-chamber fire-tube boiler furnace is proposed. The performance of suggested flame-tube was simulated using the proven computer-aided engineering software ANSYS Multiphysics. Results display proposed flame tube completely filled with moving medium without stagnant zones. Turbulent vortical combustion is observed even with the straight-through fuel supply. Active flue gas recirculation in suggested dual-chamber furnace reduces emissions of pollutants. Diminution of wall heat fluxes allows boiler operation at lower water treatment costs.
LEP vacuum chamber, cross-section
CERN PhotoLab
1983-01-01
Cross-section of the final prototype for the LEP vacuum chamber. The elliptic main-opening is for the beam. The small channel to the left is for the cooling water, to carry away the heat deposited by the synchrotron radiation. The square channel to the right houses the Non-Evaporable Getter (NEG) pump. The chamber is made from extruded aluminium. Its outside is clad with lead, to stop the synchrotron radiation emitted by the beam. For good adherence between Pb and Al, the Al chamber was coated with a thin layer of Ni. Ni being slightly magnetic, some resulting problems had to be overcome. See also 8301153.
Note: Small anaerobic chamber for optical spectroscopy
Energy Technology Data Exchange (ETDEWEB)
Chauvet, Adrien A. P., E-mail: adrien.chauvet@gmail.com; Chergui, Majed [Ecole Polytechnique Fédérale de Lausanne (EPFL), Laboratoire de Spectroscopie Ultrarapide, ISIC, Faculté des Sciences de Base, Station 6, 1015 Lausanne (Switzerland); Agarwal, Rachna; Cramer, William A. [Department of Biological Sciences, Purdue University, West Lafayette, Indiana 47907 (United States)
2015-10-15
The study of oxygen-sensitive biological samples requires an effective control of the atmosphere in which they are housed. In this aim however, no commercial anaerobic chamber is adequate to solely enclose the sample and small enough to fit in a compact spectroscopic system with which analysis can be performed. Furthermore, spectroscopic analysis requires the probe beam to pass through the whole chamber, introducing a requirement for adequate windows. In response to these challenges, we present a 1 l anaerobic chamber that is suitable for broad-band spectroscopic analysis. This chamber has the advantage of (1) providing access, via a septum, to the sample and (2) allows the sample position to be adjusted while keeping the chamber fixed and hermetic during the experiment.
Structural Analysis of Extended Plasma Focus Chamber
International Nuclear Information System (INIS)
Mohd Azhar Ahmad; Abdul Halim Baijan; Siti Aiasah Hashim
2016-01-01
Accelerator Development Centre (ADC) of Nuclear Malaysia intends to upgrade the plasma focus device. It involves the extension part placed on top of the existing plasma focus vacuum chamber. This extended vacuum chamber purposely to give an extra space in conducting experiments on the existing plasma focus chamber. The aim of upgrading the plasma focus device is to solve the limitation in research and analysis of sample due to its done in an open system that cause analysis of samples is limited and less optimal. This extended chamber was design in considering the ease of fabrication as well as durability of its structural. Thus, this paper discusses the structural analysis in term of pressure loading effect in extended chamber. (author)
Plasma chemistry in wire chambers
International Nuclear Information System (INIS)
Wise, J.
1990-05-01
The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed
Wire chamber degradation at the Argonne ZGS
International Nuclear Information System (INIS)
Haberichter, W.; Spinka, H.
1986-01-01
Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM
Drift chamber vertex detectors for SLC/LEP
Energy Technology Data Exchange (ETDEWEB)
Hayes, K G
1988-03-01
Factors influencing the design of drift chamber vertex detectors for SLC and LEP are discussed including global strategy, chamber gas, cell design, and signal processing. The designs of the vertex chambers for the L3 and OPAL experiments at LEP and the Mark II experiment at the SLC are described.
Radon-daughter chamber instrumentation system reference manual
International Nuclear Information System (INIS)
Showalter, R.; Johnson, L.
1985-01-01
The radon-daughter chamber instrumentation system collects environmental data from the radon-daughter chamber. These data are then recorded on a Tandberg system tape cartridge and transmitted to the HP-1000 computer for processing. Generators which inject radon and condensation nuclei into the chamber are also included with the instrumentation system
Nuclear design considerations for Z-IFE chambers
Energy Technology Data Exchange (ETDEWEB)
Meier, W.R. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)]. E-mail: meier5@llnl.gov; Schmitt, R.C. [Bettis Atomic Power Laboratory, Pittsburgh, PA 15203 (United States); Abbott, R.P. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Latkowski, J.F. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States); Reyes, S. [Lawrence Livermore National Laboratory, P.O. Box 808, L-641, Livermore, CA 94551 (United States)
2006-02-15
Z-pinch driven IFE (Z-IFE) requires the design of a repetitive target insertion system that allows coupling of the pulsed power to the target with adequate standoff, and a chamber that can withstand blast and radiation effects from large yield targets. The present strategy for Z-IFE is to use high yield targets ({approx}2-3 GJ/shot), low repetition rate per chamber ({approx}0.1 Hz), and 10 chambers per power plant. In this study, we propose an alternative power plant configuration that uses very high yield targets (20 GJ/shot) in a single chamber operating at 0.1 Hz. A thick-liquid-wall chamber is proposed to absorb the target emission (X-rays, debris and neutrons) and mitigate the blast effects on the chamber wall. The target is attached to the end of a conical shaped recyclable transmission line (RTL) made from a solid coolant (e.g., frozen flibe), or a material that is easily separable from the coolant (e.g., steel). The RTL/target assembly is inserted through a single opening at the top of the chamber for each shot. This study looks at the RTL material choice from a safety and environmental point of view. Materials were assessed according to waste disposal rating (WDR) and contact dose rate (CDR). Neutronics calculations, using the TART2002 Monte Carlo code from Lawrence Livermore National Laboratory (LLNL), were performed for the RTL and Z-IFE chamber, and key results reported here.
International Nuclear Information System (INIS)
Zhu, Xiuping; Logan, Bruce E.
2013-01-01
Highlights: ► A new type of electro-Fenton system was developed for wastewater treatment. ► Degradation efficiency of organic pollutants was substantially improved. ► Operation cost was greatly reduced compared to other microbial fuel cell designs. -- Abstract: Electro-Fenton reactions can be very effective for organic pollutant degradation, but they typically require non-sustainable electrical power to produce hydrogen peroxide. Two-chamber microbial fuel cells (MFCs) have been proposed for pollutant treatment using Fenton-based reactions, but these types of MFCs have low power densities and require expensive membranes. Here, more efficient dual reactor systems were developed using a single-chamber MFC as a low-voltage power source to simultaneously accomplish H 2 O 2 generation and Fe 2+ release for the Fenton reaction. In tests using phenol, 75 ± 2% of the total organic carbon (TOC) was removed in the electro-Fenton reactor in one cycle (22 h), and phenol was completely degraded to simple and readily biodegradable organic acids. Compared to previously developed systems based on two-chamber MFCs, the degradation efficiency of organic pollutants was substantially improved. These results demonstrate that this system is an energy-efficient and cost-effective approach for industrial wastewater treatment of certain pollutants
CERN PhotoLab
1978-01-01
The picture shows a "Flat-Fish" vacuum chamber being prepared in the ISR workshop for testing prior to installation in the Split Field Magnet (SFM) at intersection I4. The two shells of each part were hydroformed from 0.15 mm thick inconel 718 sheet (with end parts in inconel 600 for easier manual welding to the arms) and welded toghether with two strips which were attached by means of thin stainless steel sheets to the Split Field Magnet poles in order to take the vertical component of the atmospheric pressure force. This was the thinnest vacuum chamber ever made for the ISR. Inconel material was chosen for its high elastic modulus and strenght at chamber bake-out temperature. In this picture the thin sheets transferring the vertical component of the atmosferic pressure force are attached to a support frame for testing. See also 7712182, 7712179.
PWCs and drift chambers at ISABELLE
International Nuclear Information System (INIS)
Okuno, H.; Teramoto, Y.; Wheeler, C.D.
1978-01-01
Rate effects in proportional chambers and drift chambers are addressed first. The widely used high-gas-gain chambers would have impaired performance at ISABELLE data rates. Improvement can be expected with lower gas gain, and this possibility is investigated with respect to position and time resolution. Results on chamber lifetime are summarized; space-charge effects, gain saturation, and radiation hardness of electronics are considered. The resolution of drift chambers is discussed in some detail; time resolution, double pulse resolution, and momentum resolution and multiple scattering are included. The expected high multiplicity of tracks from a single event, the high event rates, and the requirement for low gas gain necessitate revision of the methods for measuring the second coordinate. Known methods of two-dimensional point localization are summarized according to spatial accuracy, electronics requirements, and multihit capability. Delay lines, charge division, and cathode strips are considered. Particle identification by means of measurement of the relativistic rise of energy loss by conventional and unconventional means was investigated. 32 references, 3 figures, 4 tables
Improved climatic chamber for desiccation simulation
Directory of Open Access Journals (Sweden)
Lozada Catalina
2016-01-01
Full Text Available The climatic chamber at the Universidad de Los Andes was improved for modeling desiccation in soil layers. This chamber allows the measurement of different environmental variables. In this research, evaporation tests were conducted in water imposing boundary conditions for drying, and then these tests were performed in a soil layer. The soil was prepared from a slurry state and was drying controlling the temperature, the infrared radiation, the wind velocity, and the relative humidity. In the first part of this paper, a description of the climatic chamber, operation ranges and theoretical work principles of the climatic chamber are presented. Then, the second part shows the results for desiccation in water and soil. The desiccation tests performed with the climatic chamber allow simulating all environmental conditions accurately during drying coupling the effect of all environmental variables. As a result, the evaporation rate increases with infrared radiation in soil and water. The rate at the beginning of the desiccation tests in clays is the same as in water. However, this evaporation rate decreases as the soil becomes desiccated.
A large volume striped bass egg incubation chamber: design and comparison with a traditional method
Harper, C.J.
2009-01-01
I conducted a comparative study of a new jar design (experimental chamber) with a standard egg incubation vessel (McDonald jar). Experimental chambers measured 0.4 m in diameter by 1.3 m in height and had a volume of 200 L. McDonald hatching jars measured 16 cm in diameter by 45 cm in height and had a volume of 6 L. Post-hatch survival was estimated at 48, 96 and 144 h. Stocking rates resulted in an average egg density of 21.9 eggs ml-1 (range = 21.6 – 22.1) for McDonald jars and 10.9 eggs ml-1 (range = 7.0 – 16.8) for experimental chambers. I was unable to detect an effect of container type on survival to 48, 96 or 144 h. At 144 h striped bass fry survival averaged 37.3% for McDonald jars and 34.2% for experimental chambers. Survival among replicates was significantly different. Survival of striped bass significantly decreased between 96 and 144 h. Mean survival among replicates ranged from 12.4 to 57.3%. I was unable to detect an effect of initial stocking density on survival. Experimental jars allow for incubation of a larger number of eggs in a much smaller space. As hatchery production is often limited by space or water supply, experimental chambers offer an alternative to extending spawning activities, thereby reducing manpower and cost. However, the increase in the number of eggs per rearing container does increase the risk associated with catastrophic loss of a production unit. I conclude the experimental chamber is suitable for striped bass egg incubation.
Mixed field dosimetry with the twin chamber technique
International Nuclear Information System (INIS)
Burger, G.; Maier, E.
1974-04-01
For the separate dosimetry of the neutron- and gamma-component in a mixed beam it is principally possible to use two ionization chambers with different ratios of neutron- to gamma sensitivity. Several authors proposed for this purpose the use of a homogenious TE-chamber filled with the TE-gas and of a carbon-chamber filled with CO 2 -gas. This chamber combination is also commercially available in several countries. The chambers are normally equipped with a continuous gas-flow provision and with a waterproof-housing for the use within liquid phantoms. The application of such chambers for mixed field dosimetry in the intercomparison project of the ICRU at the RARAF-facility in Brookhaven (International Neutron Dosimetry Intercomparison - INDI) is described. (orig./HP) [de
Drift chamber tracking with neural networks
International Nuclear Information System (INIS)
Lindsey, C.S.; Denby, B.; Haggerty, H.
1992-10-01
We discuss drift chamber tracking with a commercial log VLSI neural network chip. Voltages proportional to the drift times in a 4-layer drift chamber were presented to the Intel ETANN chip. The network was trained to provide the intercept and slope of straight tracks traversing the chamber. The outputs were recorded and later compared off line to conventional track fits. Two types of network architectures were studied. Applications of neural network tracking to high energy physics detector triggers is discussed
Proposal of a growth chamber for growing Super-Dwarf Rice in Space Agriculture
Hirai, Hiroaki; Kitaya, Yoshiaki; Tsukamoto, Koya; Yamashita, Youichirou; Hirai, Takehiro
Space agriculture needs to be considered to supply food for space crew who stay in space over an extended time period. So far crops such as wheat, onion, oat, pea and lettuce grew to explore the possibility of space agriculture. Although rice is a staple food for most of the world, research on rice cultivation in space has not been done much. Rice grains are nutrient-rich with carbohydrate, protein and dietary fiber. Moreover, rice is a high yield crop and harvested grains have a long shelf life. However, the plant height of standard rice cultivars is relatively long, requiring much space. In addition, rice plants require higher light intensities for greater yield. For these reasons, it is difficult to establish facilities for rice culture in a limited space with a low cost. We propose to employee a super-dwarf cultivar and a small growth chamber with a new type of LEDs. The super-dwarf rice is a short-grain japonica variety and the plant height is approximately 20 cm that is one-fifth as tall as standard cultivars. The LED light used as a light source for this study can provide full spectrum of 380 nm to 750 nm. Air temperature and humidity were controlled by a Peltier device equipped in the chamber. The characteristics of the new type of LEDs and other equipments of the chamber and the ground based performance of super-dwarf rice plants grown in the chamber will be reported.
Making MUSIC: A multiple sampling ionization chamber
International Nuclear Information System (INIS)
Shumard, B.; Henderson, D.J.; Rehm, K.E.; Tang, X.D.
2007-01-01
A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction
Making MUSIC: A multiple sampling ionization chamber
Shumard, B.; Henderson, D. J.; Rehm, K. E.; Tang, X. D.
2007-08-01
A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the (α, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for (α, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only (α, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. × 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the (α, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the (α, p) reaction to reach the anode segment below the reaction.
Making MUSIC: A multiple sampling ionization chamber
Energy Technology Data Exchange (ETDEWEB)
Shumard, B. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)]. E-mail: shumard@phy.anl.gov; Henderson, D.J. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Rehm, K.E. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States); Tang, X.D. [Argonne National Laboratory, Building 203 H-113, Argonne, IL 60439 (United States)
2007-08-15
A multiple sampling ionization chamber (MUSIC) was developed for use in conjunction with the Atlas scattering chamber (ATSCAT). This chamber was developed to study the ({alpha}, p) reaction in stable and radioactive beams. The gas filled ionization chamber is used as a target and detector for both particles in the outgoing channel (p + beam particles for elastic scattering or p + residual nucleus for ({alpha}, p) reactions). The MUSIC detector is followed by a Si array to provide a trigger for anode events. The anode events are gated by a gating grid so that only ({alpha}, p) reactions where the proton reaches the Si detector result in an anode event. The MUSIC detector is a segmented ionization chamber. The active length of the chamber is 11.95 in. and is divided into 16 equal anode segments (3.5 in. x 0.70 in. with 0.3 in. spacing between pads). The dead area of the chamber was reduced by the addition of a Delrin snout that extends 0.875 in. into the chamber from the front face, to which a mylar window is affixed. 0.5 in. above the anode is a Frisch grid that is held at ground potential. 0.5 in. above the Frisch grid is a gating grid. The gating grid functions as a drift electron barrier, effectively halting the gathering of signals. Setting two sets of alternating wires at differing potentials creates a lateral electric field which traps the drift electrons, stopping the collection of anode signals. The chamber also has a reinforced mylar exit window separating the Si array from the target gas. This allows protons from the ({alpha}, p) reaction to be detected. The detection of these protons opens the gating grid to allow the drift electrons released from the ionizing gas during the ({alpha}, p) reaction to reach the anode segment below the reaction.
Simple Cloud Chambers Using Gel Ice Packs
Kamata, Masahiro; Kubota, Miki
2012-01-01
Although cloud chambers are highly regarded as teaching aids for radiation education, school teachers have difficulty in using cloud chambers because they have to prepare dry ice or liquid nitrogen before the experiment. We developed a very simple and inexpensive cloud chamber that uses the contents of gel ice packs which can substitute for dry…
Simplified models for dark matter face their consistent completions
Energy Technology Data Exchange (ETDEWEB)
Gonçalves, Dorival; Machado, Pedro A. N.; No, Jose Miguel
2017-03-01
Simplified dark matter models have been recently advocated as a powerful tool to exploit the complementarity between dark matter direct detection, indirect detection and LHC experimental probes. Focusing on pseudoscalar mediators between the dark and visible sectors, we show that the simplified dark matter model phenomenology departs significantly from that of consistent ${SU(2)_{\\mathrm{L}} \\times U(1)_{\\mathrm{Y}}}$ gauge invariant completions. We discuss the key physics simplified models fail to capture, and its impact on LHC searches. Notably, we show that resonant mono-Z searches provide competitive sensitivities to standard mono-jet analyses at $13$ TeV LHC.
An experimental propane bubble chamber
International Nuclear Information System (INIS)
Rogozinski, A.
1957-01-01
Describes a propane bubble chamber 10 cm in diameter and 5 cm deep. The body of the chamber is in stainless steel, and it has two windows of polished hardened glass. The compression and decompression of the propane are performed either through a piston in direct contact with the liquid, or by the action on the liquid, through a triple-mylar-Perbunan membrane, of a compressed gas. The general and also optimum working conditions of the chamber are described, and a few results are given concerning, in particular, the tests of the breakage-resistance of the windows and the measurements of the thermal expansion of the compressibility isotherm for the propane employed. (author) [fr
Very high intensity reaction chamber design
International Nuclear Information System (INIS)
Devaney, J.J.
1975-09-01
The problem of achieving very high intensity irradiation by light in minimal regions was studied. Three types of irradiation chamber are suggested: the common laser-reaction chamber, the folded concentric or near-concentric resonator, and the asymmetric confocal resonator. In all designs the ratio of high-intensity illuminated volume to other volume is highly dependent (to the 3 / 2 power) on the power and fluence tolerances of optical elements, primarily mirrors. Optimization of energy coupling is discussed for the common cavity. For the concentric cavities, optimization for both coherent and incoherent beams is treated. Formulae and numerical examples give the size of chambers, aspect ratios, maximum pass number, image sizes, fluences, and the like. Similarly for the asymmetric confocal chamber, formulae and numerical examples for fluences, dimensions, losses, and totally contained pass numbers are given
Liquid ionization chambers for LET determination
DEFF Research Database (Denmark)
Kaiser, Franz-Joachim; Bassler, Niels; Tölli, Heikki
Liquid ionization chambers [1] (LICs) have have been used in the last decades as background dosemeters. Since a few years LICs are also commercially available for dosimetry and are used for measurements of dose distributions where a high spatial distribution is necessary. Also in the last decades...... a differential equation applying several simplifications and approximations leading to discrepancies between theory and experiments [3]. The theory predicts the collection efficiency as a function of the electrical field and was applied for both air filled ionization chambers and liquid filled ionization...... chambers. For liquids the LET can be roughly deduced from the collection efficiency dependency on the electrical field inside a liquid ionization chambers [4] using an extrapolation method. We solved the fundamental differential equation again presented by Jaffe numerically, but now taking into account...
Federal Laboratory Consortium — The Doriot Climatic Chambers reproduce environmental conditions occurring anywhere around the world. They provide an invaluable service by significantly reducing the...
Practical electron dosimetry: a comparison of different types of ionization chambers
International Nuclear Information System (INIS)
Dohm, O.S.; Christ, G.
2002-01-01
Since Markus chambers are no longer recommended in the 1997 DIN 6800-2 version there are uncertainties as to the use of alternative chamber types for electron dosimetry. Therefore, we performed a comparison between different types of ionization chambers. In particular, the widespread Farmer and Roos chambers were compared with the Markus chamber for polarity effect, chamber-to-chamber variation, and deviations of the measured absorbed dose relative to the value obtained with the Roos chamber (which is regarded as an ideal Bragg-Gray-chamber). The perturbation correction factor at 60 Co radiation was determined experimentally as 1,029 ± 0,5% (Roos chamber) and 1,018 ± 0,5% (Markus chamber) for the investigated plane-parallel chambers. In addition, we could show that the Roos chambers do not have a larger chamber-to-chamber variation than the Farmer chambers. Likewise, our results suggest that Farmer chambers could be used for electron energies above 6 MeV. (orig.) [de
Energy Technology Data Exchange (ETDEWEB)
Choi, Sun Young [Hallym University Sacred Heart Hospital, Anyang (Korea, Republic of); Kim, Ah Hyun; Lee, Do Yun; Lee, Kwang Hun; Won, Jong Yun [Yonsei University College of Medicine, Severance Hospital, Seoul (Korea, Republic of); Kim, Kyung Ah [Inje University Ilsan Paik Hospital, Ilsan (Korea, Republic of)
2010-12-15
We assessed the outcomes of a simplified technique for the percutaneous placement of a hepatic artery port-catheter system for chemotherapy infusion in advanced hepatocellular carcinoma with portal vein invasion. From February 2003 to February 2008, percutaneous hepatic artery port-catheter insertion was performed in 122 patients who had hepatocellular carcinoma with portal vein invasion. The arterial access route was the common femoral artery. The tip of the catheter was wedged into the right gastroepiploic artery without an additional fixation device. A side hole was positioned at the distal common hepatic artery to allow the delivery of chemotherapeutic agents into the hepatic arteries. Coil embolization was performed only to redistribute to the hepatic arteries or to prevent the inadvertent delivery of chemotherapeutic agents into extrahepatic arteries. The port chamber was created at either the supra-inguinal or infra-inguinal region. Technical success was achieved in all patients. Proper positioning of the side hole was checked before each scheduled chemotherapy session by port angiography. Catheter-related complications occurred in 19 patients (16%). Revision was achieved in 15 of 18 patients (83%). This simplified method demonstrates excellent technical feasibility, an acceptable range of complications, and is hence recommended for the management of advanced hepatocellular carcinoma with portal vein thrombosis
Sensitivity of gaseous xenon ionisation chambers (1961)
International Nuclear Information System (INIS)
Schuhl, C.
1960-01-01
It seems advantageous to fill an ionization chamber with xenon gas when this chamber is used for measuring a low intensity and high energy electron or positron beam, or monitoring a gamma beam. In the study of 5 to 50 MeV electrons, xenon allows for the ionization chamber yield, an improvement of a factor 4,5. (author) [fr
Ionization chamber correction factors for MR-linacs.
Pojtinger, Stefan; Dohm, Oliver Steffen; Kapsch, Ralf-Peter; Thorwarth, Daniela
2018-06-07
Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B . The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0-2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.
Ionization chamber correction factors for MR-linacs
Pojtinger, Stefan; Steffen Dohm, Oliver; Kapsch, Ralf-Peter; Thorwarth, Daniela
2018-06-01
Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B. The purpose of this study is to systematically investigate k B for a typical reference setup for commercially available ionization chambers with different magnetic field strengths. The Monte Carlo simulation tool EGSnrc was used to simulate eight commercially available ionization chambers in magnetic fields whose magnetic flux density was in the range of 0–2.5 T. To validate the simulation, the influence of the magnetic field was experimentally determined for a PTW30013 Farmer-type chamber for magnetic flux densities between 0 and 1.425 T. Changes in the detector response of up to 8% depending on the magnetic flux density, on the chamber geometry and on the chamber orientation were obtained. In the experimental setup, a maximum deviation of less than 2% was observed when comparing measured values with simulated values. Dedicated values for two MR-linac systems (ViewRay MRIdian, ViewRay Inc, Cleveland, United States, 0.35 T/ 6 MV and Elekta Unity, Elekta AB, Stockholm, Sweden, 1.5 T/7 MV) were determined for future use in reference dosimetry. Simulated values for thimble-type chambers are in good agreement with experiments as well as with the results of previous publications. After further experimental validation, the results can be considered for definition of standard protocols for purposes of reference dosimetry in MRgRT.
Simplified Freeman-Tukey test statistics for testing probabilities in ...
African Journals Online (AJOL)
This paper presents the simplified version of the Freeman-Tukey test statistic for testing hypothesis about multinomial probabilities in one, two and multidimensional contingency tables that does not require calculating the expected cell frequencies before test of significance. The simplified method established new criteria of ...
International Nuclear Information System (INIS)
Dupas, P.; Schneiter, J.R.
1996-01-01
EDF has developed a software package of simplified methods (proprietary ones or from literature) in order to study the thermal and mechanical behavior of a PWR pressure vessel during a severe accident involving a corium localization in the vessel lower head. Using a part of this package, the authors can evaluate for instance successively: the heat flux at the inner surface of the vessel (conductive or convective pool of corium); the thermal exchange coefficient between the vessel and the outside (dry pit or flooded pit, watertight thermal insulation or not); the complete thermal evolution of the vessel (temperature profile, melting); the possible global plastic failure of the vessel; the creep behavior in the thickness of the vessel. These simplified methods are a cost effective alternative to finite element calculations which are yet used to validate the previous methods, waiting for experimental results to come
Bubble chamber: Omega production and decay
1973-01-01
This image is of real particle tracks taken from the CERN 2 m liquid hydrogen bubble chamber and shows the production and decay of a negative omega particle. A negative kaon enters the chamber which decays into many particles, including a negative omega that travels a short distance before decaying into more particles. The invention of bubble chambers in 1952 revolutionized the field of particle physics, allowing real tracks left by particles to be seen and photographed by expanding liquid that had been heated to boiling point.
Evaluation of carbon dioxide dissipation within a euthanasia chamber.
Djoufack-Momo, Shelly M; Amparan, Ashlee A; Grunden, Beverly; Boivin, Gregory P-
2014-07-01
CO₂ euthanasia is used widely for small laboratory animals, such as rodents. A common necessity in many animal research facilities is to euthanize mice in sequential batches. We assessed the effects of several variables on the time it took for CO₂ to dissipate within a chamber. Using standard euthanasia time, changes in flow rate were compared between a slow 15% fill rate for 7 min, and a slow 15% followed by a rapid 50% filling for a total of 5 min. Additional variables assessed included the effects of opening the lid after the completion of chamber filling, turning the chamber over after completion of filling, and the use and removal of a cage from within the chamber. For all trials, CO₂ levels in the chambers peaked between 50% and 80%. After the gas was turned off, the concentration of CO₂ dropped to below 10% COv within 2 min, except when the lid was left on the chamber, where concentration levels remained above 10% after 20 min. CO₂ dissipation was significantly faster when the chamber was turned upside down after filling. Significant interaction effects occurred among the factors of cage presence within the chamber, flow rate, and chamber position. Only leaving the lid on the chamber had any practical implication for delaying CO₂ dissipation. We recommend that users allow 2 min for CO₂ to clear from the chamber before subsequent euthanasia procedures, unless the chamber is manipulated to increase the dissipation rate.
D0 central tracking chamber performance studies
International Nuclear Information System (INIS)
Pizzuto, D.
1991-12-01
The performance of the completed DO central tracking chamber was studied using cosmic rays at the State University of New York at Stony Brook. Also studied was a prototype tracking chamber identical in design to the completed DO tracking chamber. The prototype chamber was exposed to a collimated beam of 150 GeV pions at the Fermilab NWA test facility. Results indicate an RΦ tracking resolution compatible with the limitations imposed by physical considerations, excellent 2 track resolution, and a high track reconstruction efficiency along with a good rejection power against γ → e + e - events
Cost-based optimizations of power density and target-blanket modularity for 232Th/233U-based ADEP
International Nuclear Information System (INIS)
Krakowski, R.A.
1995-01-01
A cost-based parametric systems model is developed for an Accelerator-Driven Energy Production (ADEP) system based on a 232 Th/ 233 U fuel cycle and a molten-salt (LiF/BeF 2 /ThF 3 ) fluid-fuel primary system. Simplified neutron-balance, accelerator, reactor-core, chemical-processing, and balance-of-plant models are combined parametrically with a simplified costing model. The main focus of this model is to examine trade offs related to fission power density, reactor-core modularity, 233 U breeding rate, and fission product transmutation capacity
International Nuclear Information System (INIS)
Dupas, P.
1996-01-01
EDF has developed a software package of simplified methods (proprietary ones from literature) in order to study the thermal and mechanical behaviour of a PWR pressure vessel during a severe accident involving a corium localization in the vessel lower head. Using a part of this package, we can evaluate for instance successively: the heat flux at the inner surface of the vessel (conductive or convective pool of corium); the thermal exchange coefficient between the vessel and the outside (dry pit or flooded pit, watertight thermal insulation or not); the complete thermal evolution of the vessel (temperature profile, melting); the possible global plastic failure of the vessel; the creep behaviour in the vessel. These simplified methods are low cost alternative to finite element calculations which are yet used to validate the previous methods, waiting for experimental results to come. (authors)
Organizing for low cost space operations - Status and plans
Lee, C.
1976-01-01
Design features of the Space Transportation System (vehicle reuse, low cost expendable components, simple payload interfaces, standard support systems) must be matched by economical operational methods to achieve low operating and payload costs. Users will be responsible for their own payloads and will be charged according to the services they require. Efficient use of manpower, simple documentation, simplified test, checkout, and flight planning are firm goals, together with flexibility for quick response to varying user needs. Status of the Shuttle hardware, plans for establishing low cost procedures, and the policy for user charges are discussed.
International Nuclear Information System (INIS)
Sorensen, H.; Nordskov, A.; Sass, B.; Visler, T.
1987-01-01
A simplified version of a deuterium pellet gun based on the pipe gun principle is described. The pipe gun is made from a continuous tube of stainless steel and gas is fed in from the muzzle end only. It is indicated that the pellet length is determined by the temperature gradient along the barrel right outside the freezing cell. Velocities of around 1000 m/s with a scatter of +- 2% are obtained with a propellant gas pressure of 40 bar
Simplified nuclear plant design for tomorrow's energy needs
International Nuclear Information System (INIS)
Slember, R.
1989-09-01
Commercial nuclear powered plants play an important role in the strategic energy plans of many countries throughout the world. Many energy planners agree that nuclear plants will have to supply an increasing amount of electrical energy in the 1990s and beyond. Just as other major industries are continually taking steps to update and improve existing products, the United States' nuclear industry has embarked on a program to simplify plant systems, shorten construction time and improve economics for new plant models. One of the models being developed by Westinghouse Electric Corporation and Burns and Roe Company is the Advanced Passive 600 MWe design which incorporates safety features that passively protect the reactor during assumed abnormal operating events. These passive safety systems utilize natural circulation/cooling for mitigating abnormal events and simplify plant design and operation. This type of system eliminates the need for costly active safety grade components, results in a reduction of ancillary equipment and assists in shortening construction time. The use of passive safety systems also permits design simplification of the auxiliary systems effectively reducing operating and maintenance requirements. Collectively, the AP600 design features result in a safe plant that addresses and alleviates the critical industry issues that developed in the 1980s. Further, the design addresses utility and regulatory requirements for safety, reliability, maintainability, operations and economics. Program results to date give confidence that the objectives of the Advanced Passive 600 design are achievable through overall plant simplification. The report will include timely results from the work being performed on the salient technical features of the design, plant construction and operation. Other required institutional changes, such as the prerequisite for a design which is complete and licensed prior to start of construction, will also be presented
Energy Technology Data Exchange (ETDEWEB)
Danilov, M; Nagovizin, V; Hasemann, H; Michel, E; Schmidt-Parzefall, W; Wurth, R; Kim, P
1983-11-15
The ARGUS detector came into operation at the DORIS-II e/sup +/s/sup -/ storage ring at the end of 1982. Its two meter long drift chamber contains 5940 sense and 24588 field wires organized in uniform 18x18.8 mm/sup 2/ drift cells filling the whole volume. These cells form 36 layers, 18 of which provide stereo views. Each sense wire is equipped with a single hit TDC and ADC for coordinate and dE/dx measurements. The chamber is operated with propane to improve momentum and dE/dx resolution. The drift chamber design and initial performance are presented. With a very crude space-time relation approximation and without all the necessary corrections applied a spatial resolution of about 200 ..mu..m was obtained for half of the drift cell volume. Further corrections should improve this result. An intrinsic dE/dx resolution of 4.2% and an actual resolution of 5% were obtained for cosmic muons and also for Bhabha scattered electrons. An actual dE/dx resolution of 5.6% was obtained for pions from e/sup +/e/sup -/ annihilation data with almost no track selection. A relativistic rise of 30% was observed in good agreement with theory. The long-term stability is still to be investigated.
The wide gap resistive plate chamber
International Nuclear Information System (INIS)
Crotty, I.; Lamas Valverde, J.; Hatzifotiadou, D.; Williams, M.C.S.; Zichichi, A.
1995-01-01
The resistive plate chamber (RPC) has good time and position resolution; these factors (coupled to its simple construction) make it an attractive candidate for muon trigger systems at future colliders. However, operated in spark mode, the RPC has severe rate problems that make it unusable above 10 Hz/cm 2 . We have previously published our results concerning the operation of the RPC in spark and in avalanche mode; we have shown that the rate limit can be increased to 150 Hz/cm 2 if the RPC is operated in avalanche mode. Here, we discuss the performance of chambers with 6 and 8 mm gas gaps (compared to the more usual 2 mm gap). We outline the reasons for this choice, and also discuss anode versus cathode strip readout. We have measured the efficiency versus flux, and also show that an enhanced rate limit can be obtained if only a small region of the chamber is exposed to the beam (spot illumination). Finally we have tested the performance of chambers constructed with other materials for the resistiv e plate and compare it to chambers constructed with our preferred plastic, melamine laminate. (orig.)
Dilution refrigeration with multiple mixing chambers
International Nuclear Information System (INIS)
Coops, G.M.
1981-01-01
A dilution refrigerator is an instrument to reach temperatures in the mK region in a continuous way. The temperature range can be extended and the cooling power can be enlarged by adding an extra mixing chamber. In this way we obtain a double mixing chamber system. In this thesis the theory of the multiple mixing chamber is presented and tested on its validity by comparison with the measurements. Measurements on a dilution refrigerator with a circulation rate up to 2.5 mmol/s are also reported. (Auth.)
Olomola, A.S.
1992-01-01
In Nigeria, small-scale farmers are reluctant to borrow from formal institutions because of high transaction costs. This paper examines the components and determinants of borrowing transaction costs and argues that unless the loan administrative strategies are simplified and channels of loan delivery diversified, farmers would continue to find it difficult to use formal loans. Borrowing transaction costs are defined as the administrative expenses and transportation cost incurred by borrowers ...
Simplified Models for Dark Matter Searches at the LHC
Abdallah, Jalal; Arbey, Alexandre; Ashkenazi, Adi; Belyaev, Alexander; Berger, Joshua; Boehm, Celine; Boveia, Antonio; Brennan, Amelia; Brooke, Jim; Buchmueller, Oliver; Buckley, Matthew; Busoni, Giorgio; Calibbi, Lorenzo; Chauhan, Sushil; Daci, Nadir; Davies, Gavin; De Bruyn, Isabelle; de Jong, Paul; De Roeck, Albert; de Vries, Kees; del Re, Daniele; De Simone, Andrea; Di Simone, Andrea; Doglioni, Caterina; Dolan, Matthew; Dreiner, Herbi K.; Ellis, John; Eno, Sarah; Etzion, Erez; Fairbairn, Malcolm; Feldstein, Brian; Flaecher, Henning; Feng, Eric; Fox, Patrick; Genest, Marie-Hélène; Gouskos, Loukas; Gramling, Johanna; Haisch, Ulrich; Harnik, Roni; Hibbs, Anthony; Hoh, Siewyan; Hopkins, Walter; Ippolito, Valerio; Jacques, Thomas; Kahlhoefer, Felix; Khoze, Valentin V.; Kirk, Russell; Korn, Andreas; Kotov, Khristian; Kunori, Shuichi; Landsberg, Greg; Liem, Sebastian; Lin, Tongyan; Lowette, Steven; Lucas, Robyn; Malgeri, Luca; Malik, Sarah; McCabe, Christopher; Mete, Alaettin Serhan; Morgante, Enrico; Mrenna, Stephen; Nakahama, Yu; Newbold, Dave; Nordstrom, Karl; Pani, Priscilla; Papucci, Michele; Pataraia, Sophio; Penning, Bjoern; Pinna, Deborah; Polesello, Giacomo; Racco, Davide; Re, Emanuele; Riotto, Antonio Walter; Rizzo, Thomas; Salek, David; Sarkar, Subir; Schramm, Steven; Skubic, Patrick; Slone, Oren; Smirnov, Juri; Soreq, Yotam; Sumner, Timothy; Tait, Tim M.P.; Thomas, Marc; Tomalin, Ian; Tunnell, Christopher; Vichi, Alessandro; Volansky, Tomer; Weiner, Neal; West, Stephen M.; Wielers, Monika; Worm, Steven; Yavin, Itay; Zaldivar, Bryan; Zhou, Ning; Zurek, Kathryn
2015-01-01
This document outlines a set of simplified models for dark matter and its interactions with Standard Model particles. It is intended to summarize the main characteristics that these simplified models have when applied to dark matter searches at the LHC, and to provide a number of useful expressions for reference. The list of models includes both s-channel and t-channel scenarios. For s-channel, spin-0 and spin-1 mediation is discussed, and also realizations where the Higgs particle provides a portal between the dark and visible sectors. The guiding principles underpinning the proposed simplified models are spelled out, and some suggestions for implementation are presented.
Simplified models for dark matter searches at the LHC
Energy Technology Data Exchange (ETDEWEB)
Abdallah, Jalal; Araujo, Henrique; Arbey, Alexandre; Ashkenazi, Adi; Belyaev, Alexander; Berger, Joshua; Boehm, Celine; Boveia, Antonio; Brennan, Amelia; Brooke, Jim; Buchmueller, Oliver; Buckley, Matthew; Busoni, Giorgio; Calibbi, Lorenzo; Chauhan, Sushil; Daci, Nadir; Davies, Gavin; De Bruyn, Isabelle; De Jong, Paul; De Roeck, Albert; de Vries, Kees; Del Re, Daniele; De Simone, Andrea; Di Simone, Andrea; Doglioni, Caterina; Dolan, Matthew; Dreiner, Herbi K.; Ellis, John; Eno, Sarah; Etzion, Erez; Fairbairn, Malcolm; Feldstein, Brian; Flaecher, Henning; Feng, Eric; Fox, Patrick; Genest, Marie-Hélène; Gouskos, Loukas; Gramling, Johanna; Haisch, Ulrich; Harnik, Roni; Hibbs, Anthony; Hoh, Siewyan; Hopkins, Walter; Ippolito, Valerio; Jacques, Thomas; Kahlhoefer, Felix; Khoze, Valentin V.; Kirk, Russell; Korn, Andreas; Kotov, Khristian; Kunori, Shuichi; Landsberg, Greg; Liem, Sebastian; Lin, Tongyan; Lowette, Steven; Lucas, Robyn; Malgeri, Luca; Malik, Sarah; McCabe, Christopher; Mete, Alaettin Serhan; Morgante, Enrico; Mrenna, Stephen; Nakahama, Yu; Newbold, Dave; Nordstrom, Karl; Pani, Priscilla; Papucci, Michele; Pataraia, Sophio; Penning, Bjoern; Pinna, Deborah; Polesello, Giacomo; Racco, Davide; Re, Emanuele; Riotto, Antonio Walter; Rizzo, Thomas; Salek, David; Sarkar, Subir; Schramm, Steven; Skubic, Patrick; Slone, Oren; Smirnov, Juri; Soreq, Yotam; Sumner, Timothy; Tait, Tim M. P.; Thomas, Marc; Tomalin, Ian; Tunnell, Christopher; Vichi, Alessandro; Volansky, Tomer; Weiner, Neal; West, Stephen M.; Wielers, Monika; Worm, Steven; Yavin, Itay; Zaldivar, Bryan; Zhou, Ning; Zurek, Kathryn
2015-09-01
This document a outlines a set of simplified models for dark matter and its interactions with Standard Model particles. It is intended to summarize the main characteristics that these simplified models have when applied to dark matter searches at the LHC, and to provide a number of useful expressions for reference. The list of models includes both s-channel and t-channel scenarios. For s-channel, spin-0 and spin-1 mediations are discussed, and also realizations where the Higgs particle provides a portal between the dark and visible sectors. The guiding principles underpinning the proposed simplified models are spelled out, and some suggestions for implementation are presented.
MDT Commissioning Procedures Guidelines for Certifying RFI Chambers
Beretta, M; Branchini, P; Kourkoumelis, C; Dubbert, J; Gazis, E N; Hertenberger, R; Hurst, P; Kojine, A; Lanza, A; Marin, A; Mockett, P; Petridou, C; Tskhadadze, E G; Valente, P; Wotschack, J; Xie, Y; Zhao, Z
2004-01-01
Aim of the document is the definition of a common set of guidelines and test procedures for commissioning the MDT chambers. Commissioning is different for Barrel and Endcap chambers. The former will be tested at a single chamber level before going to the ATLAS pit, ready for the last quick test before final installation, while the latter will be first tested at a single chamber level (phase one), then installed into the Small and Big Wheel sectors (SW and BW), tested after the integration (phase two) and transported to the ATLAS pit for final wheel installation. The present document concerns all tests, including those of phase two for Endcap chambers, but it is possible that some specific tests, at the moment not planned, will be implemented during the Endcap phase two commissioning. It is composed of three sections: 1 â" Guidelines for checking chamber conformity, where the main rules for declaring that chambers conform to the reference drawings and requirements are described; 2 â" Commissioning tests,...
20 CFR 404.241 - 1977 simplified old-start method.
2010-04-01
... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false 1977 simplified old-start method. 404.241... DISABILITY INSURANCE (1950- ) Computing Primary Insurance Amounts Old-Start Method of Computing Primary Insurance Amounts § 404.241 1977 simplified old-start method. (a) Who is qualified. To qualify for the old...
International Nuclear Information System (INIS)
Cheng, Cheng; Zhang, Xiaobing
2016-01-01
Highlights: • A novel two-dimensional two-phase flow model is established for the high-low pressure chambers system. • A strong packing of particles is observed at the projectile base and will cause the pressure to rise faster. • Different length–diameter ratios can affect the flow behavior through the vent-holes obviously. • The muzzle velocity decreases with the length–diameter ratio of the high-pressure chamber. - Abstract: A high-low pressure chambers system is proposed to meet the demands of low launch acceleration for informative equipment in many special fields such as Aeronautics, Astronautics and Weaponry. A two-dimensional two-phase flow numerical model is established to describe the complex physical process based on a modified two-fluid theory, which takes into account gas production, interphase drag, intergranular stress, and heat transfer between two phases. In order to reduce the computational cost, the parameters in the high-pressure chamber at the instant the vent-holes open are calculated by the zero-dimensional model as the initial conditions for the two-phase flow simulation in the high-low pressure chambers system. The simulation results reveal good agreement with the experiments and the launch acceleration of a projectile can be improved by this system. The propellant particles can be tracked clearly in both chambers and a strong packing of particles at the base of projectile will cause the pressure to rise faster than at other areas both in the axis and radial directions. The length–diameter ratio of the high-pressure chamber (a typical multi-dimensional parameter) is investigated. Different length–diameter ratios can affect the maximum pressure drop and the loss of total pressure impulse through the vent-hole, then the muzzle velocity and the launch acceleration of projectiles can be influenced directly. This article puts forward a new prediction tool for the understanding and design of transient processes in high-low pressure
Directory of Open Access Journals (Sweden)
Ertugrul Can
2016-01-01
Full Text Available Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL. Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes.
Vacuum Chamber for the Booster Bending Magnets
CERN PhotoLab
1974-01-01
To minimize eddy currents, induced by the rising magnetic field, the chamber was made from thin stainless steel of high specific electric resistance. For mechanical stength, it was corrugated in a hydro-forming process. The chamber is curved, to follow the beam's orbital path. Under vacuum, the chamber tends to staighten, the ceramic spacer along half of its length keeps it in place (see also 7402458).
Construction and performance of large flash chambers
International Nuclear Information System (INIS)
Taylor, F.E.; Bogert, D.; Fisk, R.; Stutte, L.; Walker, J.K.; Wolfson, J.; Abolins, M.; Ernwein, J.; Owen, D.; Lyons, T.
1979-01-01
The construction and performance of 12' x 12' flash chambers used in a 340 ton neutrino detector under construction at Fermilab is described. The flash chambers supply digital information with a spatial resolution of 0.2'', and are used to finely sample the shower development of the reaction products of neutrino interactions. The flash chambers are easy and inexpensive to build and are electronically read out
International Nuclear Information System (INIS)
Barasch, E.F.; Bowcock, T.J.V.; Drew, M.M.; Elliott, S.M.; Lee, B.; McIntyre, P.M.; Pang, Y.; Popovic, M.; Smith, D.D.
1990-01-01
In this paper the design for a new technology for particle track detectors is described. Using standard IC fabrication techniques, a pattern of microscopic knife edges and field-shaping electrodes can be fabricated on a silicon substrate. The knife-edge chamber uniquely offers attractive performance for the track chambers required for SSC detectors, for which no present technology is yet satisfactory. Its features include: excellent radiation hardness (10 Mrad), excellent spatial resolution (∼20 μm), short drift time (20 ns), and large pulse height (1 mV)
Multiple chamber ionization detector
International Nuclear Information System (INIS)
Solomon, E.E.
1982-01-01
An ionization smoke detector employs a single radiation source in a construction comprising at least two chambers with a center or node electrode. The radioactive source is associated with this central electrode, and its positioning may be adjusted relative to the electrode to alter the proportion of the source that protrudes into each chamber. The source may also be mounted in the plane of the central electrode, and positioned relative to the center of the electrode. The central electrode or source may be made tiltable relative to the body of the detector
21 CFR 866.2120 - Anaerobic chamber.
2010-04-01
... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...
International Nuclear Information System (INIS)
Li Yijun; Wang Dalun; Chen Suhe
1999-01-01
With fission materials of depleted uranium, natural uranium, enriched uranium, 239 Pu, and 237 Np, the authors have designed and made a series of small flat fission chamber. The authors narrated the construction of the fission chamber and its technological process of manufacture, and furthermore, the authors have measured and discussed the follow correct factor, self-absorption, boundary effect, threshold loss factor, bottom scatter and or so
Integrating cost management and work management concepts for operations
International Nuclear Information System (INIS)
Vanditmars, C.
1995-01-01
Development of B C Gas Utility Limited's integrated work and cost management system was described, with emphasis on cost management without reliance on the financial systems, and standard costing and operational side benefits. The objectives of the system were identified as dynamic monitoring and control, and local empowerment. The concept underlying the two systems was explained in detail. In the case of the work management system the ability to manage all work in operations areas was stressed, along with its universal availability. Other benefits expected included improved resource utilization, improved productivity, better control of cost, improved revenue generation, superior customer service, a simplified financial system, and improved employee motivation through empowerment
Barmatz, M. B.; Granett, D.; Lee, M. C.
1984-01-01
Uncontaminated environments for highly-pure material processing provided within completely sealed levitation chamber that suspends particles by acoustic excitation. Technique ideally suited for material processing in low gravity environment of space.
Polarity effects and apparent ion recombination in microionization chambers
Energy Technology Data Exchange (ETDEWEB)
Miller, Jessica R., E-mail: miller@humonc.wisc.edu [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin 53792 (United States); Hooten, Brian D. [Standard Imaging, Middleton, Wisconsin 53562 (United States); Micka, John A.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)
2016-05-15
Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered
Challenges Surrounding the Injection and Arrival of Targets at LIFE Fusion Chamber Center
Energy Technology Data Exchange (ETDEWEB)
Miles, R; Spaeth, M; Manes, K; Amendt, P; Tabak, M; Bond, T; Kucheyev, S; Latkowski, J; Loosmore, G; Bliss, E; Baker, K; Bhandarkar, S; Petzoldt, R; Alexander, N; Tillack, M; Holdener, D
2010-12-01
IFE target designers must consider several engineering requirements in addition to the physics requirements for successful target implosion. These considerations include low target cost, high manufacturing throughput, the ability of the target to survive the injection into the fusion chamber and arrive in a condition and physical position consistent with proper laser-target interaction and ease of post-implosion debris removal. This article briefly describes these considerations for the Laser Inertial Fusion-based Energy (LIFE) targets currently being designed.
Repair of isolated double-chambered right ventricle | El Kouache ...
African Journals Online (AJOL)
The finding of a double-chambered right ventricle (DCRV) is exceptionally rare as an isolated anomaly. It is a congenital cardiac anomaly in which the right ventricle is separated into two chambers, a proximal highpressure chamber and a distal low-pressure chamber, by anomalous muscles or fibrous tissues in the right ...
1977-01-01
This chamber is now in the National Museum of History and Technology, Smithsonian Institution, Washington, DC, USA, where it was exposed in an exhibit on the History of High Energy Accelerators (1977).
On Use of Multi-Chambered Fission Detectors for In-Core, Neutron Spectroscopy
Roberts, Jeremy A.
2018-01-01
Presented is a short, computational study on the potential use of multichambered fission detectors for in-core, neutron spectroscopy. Motivated by the development of very small fission chambers at CEA in France and at Kansas State University in the U.S., it was assumed in this preliminary analysis that devices can be made small enough to avoid flux perturbations and that uncertainties related to measurements can be ignored. It was hypothesized that a sufficient number of chambers with unique reactants can act as a real-time, foilactivation experiment. An unfolding scheme based on maximizing (Shannon) entropy was used to produce a flux spectrum from detector signals that requires no prior information. To test the method, integral, detector responses were generated for singleisotope detectors of various Th, U, Np, Pu, Am, and Cs isotopes using a simplified, pressurized-water reactor spectrum and fluxweighted, microscopic, fission cross sections, in the WIMS-69 multigroup format. An unfolded spectrum was found from subsets of these responses that had a maximum entropy while reproducing the responses considered and summing to one (that is, they were normalized). Several nuclide subsets were studied, and, as expected, the results indicate inclusion of more nuclides leads to better spectra but with diminishing improvements, with the best-case spectrum having an average, relative, group-wise error of approximately 51%. Furthermore, spectra found from minimum-norm and Tihkonov-regularization inversion were of lower quality than the maximum entropy solutions. Finally, the addition of thermal-neutron filters (here, Cd and Gd) provided substantial improvement over unshielded responses alone. The results, as a whole, suggest that in-core, neutron spectroscopy is at least marginally feasible.
Investigation of diesel engine for low exhaust emissions with different combustion chambers
Directory of Open Access Journals (Sweden)
Ghodke Pundlik R.
2015-01-01
Full Text Available Upcoming stringent Euro-6 emission regulations for passenger vehicle better fuel economy, low cost are the key challenges for engine development. In this paper, 2.2L, multi cylinder diesel engine have been tested for four different piston bowls designed for compression ratio of CR 15.5 to improve in cylinder performance and reduce emissions. These combustion chambers were verified in CFD at two full load points. 14 mode points have been derived using vehicle model run in AVL CRUISE software as per NEDC cycle based on time weightage factor. Base engine with compression ratio CR16.5 for full load performance and 14-mode points on Engine test bench was taken as reference for comparison. The bowl with flat face on bottom corner has shown reduction 25% and 12 % NOx emissions at 1500 and 3750 rpm full load points at same level of Soot emissions. Three piston bowls were tested for full load performance and 14 mode points on engine test bench and combustion chamber ‘C’ has shown improvement in thermal efficiency by 0.8%. Combinations of cooled EGR and combustion chamber ‘C’ with geometrical changes in engine have reduced exhaust NOx, soot and CO emissions by 22%, 9 % and 64 % as compared to base engine at 14 mode points on engine test bench.
Study on target interactions in emulsion chamber - Brasil-Japan emulsion chamber collaboration
Ballester, M.; Santos, C.; Bellandi Filho, J.; Chinellato, J. A.; Dobrigkeit, C.; Lattes, C. M. G.; Marques, A.; Menon, M. J.; Navia, C. E.; Sawayanagi, K.
Experimental results are presented from observations of 80 target nuclear interactions where the total gamma-ray energy is greater than or equal to 20 TeV. Evidence is presented for the existence of two types of interactions; the interpretation is given on the basis of a fire-ball model. Two-story emulsion chambers exposed at Mount Chacaltaya, in Bolivia (5,220 m above sea level), are used. Gamma rays from nuclear interactions in the target layer of petroleum pitch (1/3 of the nuclear mean free path in thickness) are detected through observations of the electron showers generated by them in the lower chamber
Climate chamber for environmentally controlled laboratory airflow experiments.
Even-Tzur, Nurit; Zaretsky, Uri; Grinberg, Orly; Davidovich, Tomer; Kloog, Yoel; Wolf, Michael; Elad, David
2010-01-01
Climate chambers have been widely used in in vitro and in vivo studies which require controlled environmental temperature and humidity conditions. This article describes a new desktop climate chamber that was developed for application of respiratory airflows on cultured nasal epithelial cells (NEC) under controlled temperature and humidity conditions. Flow experiments were performed by connecting the climate chamber to an airflow generator via a flow chamber with cultured NEC. Experiments at two controlled climate conditions, 25 degrees C and 40% relative humidity (RH) and 37 degrees C and 80%RH, were conducted to study mucin secretion from the cultures inresponse to the flow. The new climate chamber is a relatively simple and inexpensive apparatus which can easily be connected to any flow system for climate controlled flow experiments. This chamber can be easily adjusted to various in vitro experiments, as well as to clinical studies with animals or human subjects which require controlled climate conditions.
Communication: A simplified coupled-cluster Lagrangian for polarizable embedding.
Krause, Katharina; Klopper, Wim
2016-01-28
A simplified coupled-cluster Lagrangian, which is linear in the Lagrangian multipliers, is proposed for the coupled-cluster treatment of a quantum mechanical system in a polarizable environment. In the simplified approach, the amplitude equations are decoupled from the Lagrangian multipliers and the energy obtained from the projected coupled-cluster equation corresponds to a stationary point of the Lagrangian.
Communication: A simplified coupled-cluster Lagrangian for polarizable embedding
International Nuclear Information System (INIS)
Krause, Katharina; Klopper, Wim
2016-01-01
A simplified coupled-cluster Lagrangian, which is linear in the Lagrangian multipliers, is proposed for the coupled-cluster treatment of a quantum mechanical system in a polarizable environment. In the simplified approach, the amplitude equations are decoupled from the Lagrangian multipliers and the energy obtained from the projected coupled-cluster equation corresponds to a stationary point of the Lagrangian
Investigation of a multiwire proportional chamber
International Nuclear Information System (INIS)
Konijn, J.
1976-01-01
The article discusses some aspects of a prototype multiwire proportional chamber for electron detection located at IKO in Amsterdam, i.e. voltage, counting rates, noise and gas mixture (argon, ethylene bromide). The efficiency and performance of the chamber have been investigated and an error analysis is given
Triangular tube proportional wire chamber system
Energy Technology Data Exchange (ETDEWEB)
Badtke, D H; Bakken, J A; Barnett, B A; Blumenfeld, B J; Chien, C Y; Madansky, L; Matthews, J A.J.; Pevsner, A; Spangler, W J [Johns Hopkins Univ., Baltimore, MD (USA); Lee, K L [California Univ., Berkeley (USA). Lawrence Berkeley Lab.
1981-10-15
We report on the characteristics of the proportional tube chamber system which has been constructed for muon identification in the PEP-4 experiment at SLAC. The mechanical and electrical properties of the extruded aluminum triangular tubes allow these detectors to be used as crude drift chambers.
The Mark III vertex chamber and prototype test results
International Nuclear Information System (INIS)
Grab, C.
1987-07-01
A vertex chamber has been constructed for use in the Mark III experiment. The chamber is positioned inside the current main drift chamber and will be used to trigger data collection, to aid in vertex reconstruction, and to improve the momentum resolution. This paper discusses the chamber's construction and performance and tests of the prototype
International Nuclear Information System (INIS)
Carter, J.R.; Elcombe, P.A.; Hill, J.C.; Roach, C.M.; Armitage, J.C.; Carnegie, R.K.; Estabrooks, P.; Hemingway, R.; Karlen, D.; McPherson, A.; Pinfold, J.; Roney, J.M.; Routenburg, P.; Waterhouse, J.; Hargrove, C.K.; Klem, D.; Oakham, F.G.; Carter, A.A.; Jones, R.W.L.; Lasota, M.M.B.; Lloyd, S.L.; Pritchard, T.W.; Wyatt, T.R.
1990-01-01
A high precision vertex drift chamber has been installed in the OPAL experiment at LEP. The design of the chamber and the associated readout electronics is described. The performance of the system has been studied using cosmic ray muons and the results of these studies are presented. A space resolution of 50 μm in the drift direction is obtained using the OPAL central detector gas mixture at 4 bar. (orig.)
International Nuclear Information System (INIS)
Goto, Shoji; Ohmori, Shuichi; Mori, Mitchitsugu
2004-01-01
It is possible to established simplified systems and reduced space and equipments using high-efficiency Steam Injector (SI) instead of low-pressure feed water heaters in Nuclear Power Plant (NPP). The SI works as a heat exchanger through direct contact between feedwater from condenser and extracted steam from turbine. It can get a higher pressure than supplied steam pressure, so it can reduce the feedwater pumps. The maintenance and reliability are still higher because SI has no movable parts. This paper describes the analysis of the heat balance and plant efficiency of this Innovative-Simplified NPP with high-efficiency SI. The plant efficiency is compared with the electric power of 1100MWe class original BWR system and the Innovative-Simplified BWR system with SI. The SI model is adapted into the heat balance simulator with a simplified model. The results show plant efficiencies of the Innovated-Simplified BWR system are almost equal to the original BWR one. The present research is one of the projects that are carried out by Tokyo Electric Power Company, Toshiba Corporation, and six Universities in Japan, funded from the Institute of Applied Energy (IAE) of Japan as the national public research-funded program. (author)
Cost-effectiveness of human papillomavirus vaccination in the United States.
Chesson, Harrell W; Ekwueme, Donatus U; Saraiya, Mona; Markowitz, Lauri E
2008-02-01
We describe a simplified model, based on the current economic and health effects of human papillomavirus (HPV), to estimate the cost-effectiveness of HPV vaccination of 12-year-old girls in the United States. Under base-case parameter values, the estimated cost per quality-adjusted life year gained by vaccination in the context of current cervical cancer screening practices in the United States ranged from $3,906 to $14,723 (2005 US dollars), depending on factors such as whether herd immunity effects were assumed; the types of HPV targeted by the vaccine; and whether the benefits of preventing anal, vaginal, vulvar, and oropharyngeal cancers were included. The results of our simplified model were consistent with published studies based on more complex models when key assumptions were similar. This consistency is reassuring because models of varying complexity will be essential tools for policy makers in the development of optimal HPV vaccination strategies.
Considerations for Conducting Plant Research in Open Atmosphere Chambers on ISS
Wheeler, Raymond; Hummerick, Mary; Graham, Thomas; Dixit, Anirudha; Massa, Gioia
The access to spaceflight and now the International Space Station has provided plant researchers a laboratory that is in continuous freefall (near weightlessness). As veteran spaceflight investigators know too well, research in space is difficult to conduct and the experiments are often confounded by secondary events. An example of this is the distribution of water and gases in rooting systems in µ-gravity. Since the water does not settle to the ”bottom” of the rooting media in space, there can be poor distribution and movement of water and oxygen, which in turn can stress the plants. This also creates challenges for conducting ground controls where the logical approach is to use the same volume of water as in space. But under 1-g, the water does settle to the bottom of the root zone, which leaves less in the upper profile of the rooting medium. In addition, some chambers such as the Russian Svet (on Mir), Lada (ISS), and NASA’s Veggie chamber were or are open to the cabin air. This simplifies the hardware development and allows the use of cabin air for cooling and supplying CO2 to the plants. Yet it also exposes the plants to the cabin air, which could have very high CO2 levels (e.g., 3000 to 6000 ppm), low humidity, and trace contaminants that might be below the limits for human concerns but could still affect plants. A known effect of these “super-elevated” CO2 levels on many dicot species is increased transpiration due to elevated stomatal conductance, both during the light and the dark cycles. Examples of these secondary effects will be discussed, along with potential approaches for conducting adequate ground controls.
Chamber for Aerosol Deposition of Bioparticles
Kern, Roger; Kirschner, Larry
2008-01-01
Laboratory apparatus is depicted that is a chamber for aerosol deposition of bioparticles on surfaces of test coupons. It is designed for primary use in inoculating both flat and three-dimensional objects with approximately reproducible, uniform dispersions of bacterial spores of the genus Bacillus so that the objects could be used as standards for removal of the spores by quantitative surface sampling and/or cleaning processes. The apparatus is also designed for deposition of particles other than bacterial spores, including fungal spores, viruses, bacteriophages, and standard micron-sized beads. The novelty of the apparatus lies in the combination of a controllable nebulization system with a settling chamber large enough to contain a significant number of test coupons. Several companies market other nebulizer systems, but none are known to include chambers for deposition of bioparticles to mimic the natural fallout of bioparticles. The nebulization system is an expanded and improved version of commercially available aerosol generators that include nebulizers and drying columns. In comparison with a typical commercial aerosol generator, this system includes additional, higher-resolution flowmeters and an additional pressure regulator. Also, unlike a typical commercial aerosol generator, it includes stopcocks for separately controlling flows of gases to the nebulizer and drying column. To maximize the degree of uniformity of dispersion of bioaerosol, the chamber is shaped as an axisymmetrical cylinder and the aerosol generator is positioned centrally within the chamber and aimed upward like a fountain. In order to minimize electric charge associated with the aerosol particles, the drying column is made of aluminum, the drying column is in direct contact with an aluminum base plate, and three equally spaced Po-210 antistatic strips are located at the exit end of the drying column. The sides and top of the chamber are made of an acrylic polymer; to prevent
Construction of radon/radon daughter calibraton chamber
International Nuclear Information System (INIS)
Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.
1983-01-01
The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)
30 CFR 56.7807 - Flushing the combustion chamber.
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 56.7807 Section 56.7807 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Rotary Jet Piercing Rotary Jet Piercing § 56.7807 Flushing the combustion chamber. The combustion chamber...
Scale testing of a partially confined blast chamber
CSIR Research Space (South Africa)
Grundling, W
2012-10-01
Full Text Available in pressure readings. A scale model of the blast chamber, Emily, was constructed with the addition of a pendulum plate hanging concentrically covering 65% of the open area. PURPOSE OF SCALED BLAST CHAMBER The purpose of this particular test is to evaluate... PHASE Illustrated in Figure 3 and 4 are the results obtained during testing of the scaled blast chamber. In both cases the pressure dissipates over time, showing pulsating behaviour as the shockwaves reflect off the chamber walls. By looking...
Recent developments in wire chamber tracking at SSC
International Nuclear Information System (INIS)
Ogren, H.
1990-01-01
All of the major SSC proposed detectors use wire chambers in their tracking systems. The feasibility of wire chambers in an SSC detector has now been established by a number of groups planning detectors at SSC. The major advances during the past year in understanding straw tube drift chambers are presented and several innovations in gaseous wire chambers are discussed. The R and D section will concentrate on progress in drift cell design, electronics and signal processing, and engineering aspects of the tracking designs
Method of controlling weld chamber purge and cover gas atmosphere
International Nuclear Information System (INIS)
Yeo, D.
1992-01-01
A method of controlling the gas atmosphere in a welding chamber includes detecting the absence of a fuel rod from the welding chamber and, in response thereto, initiating the supplying of a flow of argon gas to the chamber to purge air therefrom. Further, the method includes detecting the entry of a fuel rod in the welding chamber and, in response thereto, terminating the supplying of the flow of argon gas to the chamber and initiating the supplying of a flow of helium gas to the chamber to purge argon gas therefrom and displace the argon gas in the chamber. Also, the method includes detecting the withdrawal of the fuel rod from the welding chamber and, in response thereto, terminating the supplying of the flow of helium gas to the chamber and initiating the supplying of argon to the chamber to purge the air therefrom. The method also includes detecting the initiation of a weld cycle and, in response thereto, momentarily supplying a flow of argon gas to the welding electrode tip for initiating the welding arc. (Author)
CERN PhotoLab
1971-01-01
An optical spark chamber developed for use in the Omega spectrometer. On the left the supporting frame is exceptionally thin to allow low momentum particles to escape and be detected outside the magnetic field.
International Nuclear Information System (INIS)
Graaf, Harry van der; Buskens, Joop; Rewiersma, Paul; Koenig, Adriaan; Wijnen, Thei
1991-06-01
The Honeycomb Strip Chamber (HSC) is a new position sensitive detector. It consists of a stack of folded foils, forming a rigid honeycomb structure. In the centre of each hexagonal cell a wire is strung. Conducting strips on the foils, perpendicular to the wires, pick up the induced avalanche charge. Test results of a prototype show that processing the signals form three adjacent strips nearest to the track gives a spatial resolution better than 64 μm for perpendicular incident tracks. The chamber performance is only slightly affected by a magnetic field. (author). 25 refs.; 21 figs
1998-01-01
About 16 000 Micro Strip Gas Chambers like this one will be used in the CMS tracking detector. They will measure the tracks of charged particles to a hundredth of a millimetre precision in the region near the collision point where the density of particles is very high. Each chamber is filled with a gas mixture of argon and dimethyl ether. Charged particles passing through ionise the gas, knocking out electrons which are collected on the aluminium strips visible under the microscope. Such detectors are being used in radiography. They give higher resolution imaging and reduce the required dose of radiation.
Energy Technology Data Exchange (ETDEWEB)
Silva, Jonas Oliveira da
2013-07-01
Mammography is an imaging method that uses X-rays. The use of ionization chambers in mammography quality control programs presents an essential role which is to verify whether the parameters of the patient exposure are correct. However, the commercial ionization chambers for dosimetry in mammography represent a high cost for small and medium size clinics that wish to have this equipment or for professionals that work with quality control programs. The innovative feature of this work was to develop ionization chambers for this purpose. In this work ionization chambers for X radiation beams in the mammography energy range were designed, constructed and characterized. The ionization chambers were tested in standard X radiation beams at the LCI/IPEN. The main characterization tests performed with the ionization chambers were: saturation curve, linearity of response, angular and energy dependence. The response stability tests of the ionization chambers were also conducted at the LCI, presenting results within 2.0 % for long-term stability. The results of the remaining tests are in accordance with international standards. These ionization chambers were also submitted to quality control tests of mammography equipment: linearity of the air kerma rates, determination of half-value layers and mean glandular doses. The results for air kerma rate linearity were less than 10 %, as recommended in international standards. The mean glandular dose obtained with the developed chambers presented values comparable to those of commercial ionization chambers tested, with an estimated variation within international standards. (author)
Evaluation of simplified dna extraction methods for EMM typing of group a streptococci
Directory of Open Access Journals (Sweden)
Jose JJM
2006-01-01
Full Text Available Simplified methods of DNA extraction for amplification and sequencing for emm typing of group A streptococci (GAS can save valuable time and cost in resource crunch situations. To evaluate this, we compared two methods of DNA extraction directly from colonies with the standard CDC cell lysate method for emm typing of 50 GAS strains isolated from children with pharyngitis and impetigo. For this, GAS colonies were transferred into two sets of PCR tubes. One set was preheated at 94oC for two minutes in the thermal cycler and cooled while the other set was frozen overnight at -20oC and then thawed before adding the PCR mix. For the cell lysate method, cells were treated with mutanolysin and hyaluronidase before heating at 100oC for 10 minutes and cooling immediately as recommended in the CDC method. All 50 strains could be typed by sequencing the hyper variable region of the emm gene after amplification. The quality of sequences and the emm types identified were also identical. Our study shows that the two simplified DNA extraction methods directly from colonies can conveniently be used for typing a large number of GAS strains easily in relatively short time.
Simulated Field Trials Using an Indoor Aerosol Test Chamber
National Research Council Canada - National Science Library
Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M
2004-01-01
.... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...
Simulated Field Trials Using An Indoor Aerosol Test Chamber
National Research Council Canada - National Science Library
Semler, D. D; Roth, A. P; Semler, K. A; Nolan, P. M
2004-01-01
.... In this method, the aerosol chamber control software manipulates circulation fan speeds, chamber vacuum and agent spray times to produce a simulated dynamic cloud within the aerosol test chamber...
Equipment for handling ionization chamber
International Nuclear Information System (INIS)
Altmann, J.
1988-01-01
The device consists of an ionization channel with an ionization chamber, of a support ring, axial and radial bearings, a sleeve, a screw gear and an electric motor. The ionization chamber is freely placed on the bottom of the ionization channel. The bottom part of the channel deviates from the vertical axis. The support ring propped against the axial bearing in the sleeve is firmly fixed to the top part of the ionization channel. The sleeve is fixed to the reactor lid. Its bottom part is provided with a recess for the radial bearing which is propped against a screw wheel firmly connected to the ionization channel. In measuring neutron flux, the screw wheel is rotated by the motor, thus rotating the whole ionization channel such that the ionization chamber is displaced into the reactor core.(J.B.). 1 fig
A simplified approach for evaluating secondary stresses in elevated temperature design
International Nuclear Information System (INIS)
Becht, C.
1983-01-01
Control of secondary stresses is important for long-term reliability of components, particularly at elevated temperatures where substantial creep damage can occur and result in cracking. When secondary stresses are considered in the design of elevated temperature components, these are often addressed by the criteria contained in Nuclear Code Case N-47 for use with elastic or inelastic analysis. The elastic rules are very conservative as they bound a large range of complex phenomena; because of this conservatism, only components in relatively mild services can be designed in accordance with these rules. The inelastic rules, although more accurate, require complex and costly nonlinear analysis. Elevated temperature shakedown is a recognized phenomenon that has been considered in developing Code rules and simplified methods. This paper develops and examines the implications of using a criteria which specifically limits stresses to the shakedown regime. Creep, fatigue, and strain accumulation are considered. The effect of elastic follow-up on the conservatism of the criteria is quantified by means of a simplified method. The level of conservatism is found to fall between the elastic and inelastic rules of N-47 and, in fact, the incentives for performing complex inelastic analyses appear to be low except in the low cycle regime. The criteria has immediate applicability to non-code components such as vessel internals in the chemical, petroleum, and synfuels industry. It is suggested that such a criteria be considered in future code rule development
Weld Development for Aluminum Fission Chamber
Energy Technology Data Exchange (ETDEWEB)
Cross, Carl Edward [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Martinez, Jesse Norris [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
2017-05-16
The Sigma welding team was approached to help fabricate a small fission chamber (roughly ½ inch dia. x ½ inch tall cylinder). These chambers are used as radiation sensors that contain small traces of radionuclides (Cf 252, U 235, and U 238) that serve to ionize gas atoms in addition to external radiation. When a voltage is applied within the chamber, the resulting ion flow can be calibrated and monitored. Aluminum has the advantage of not forming radioactive compounds when exposed to high external radiation (except from minor Na alloy content). Since aluminum has not been used before in this application, this presented an unexplored challenge.
The Compliance Cost of the U.S. Individual Income Tax System: A Second Look After Tax Reform
Blumenthal, Marsha; Slemrod, Joel
1992-01-01
Attempts to answer whether or not TRA'86 simplified or complicated taxes by comparing data from surveys of compliance costs conducted in 1982 and 1989. Concludes that tax reform did not reverse the growth in compliance costs in the 1980's.
BEBC Big European Bubble Chamber
CERN PhotoLab
1974-01-01
A view of the dismantling of the magnet of BEBC, the 3.7 m European Bubble Chamber : iron magnetic shielding ; lower and upper parts of the vacuum enclosure of the magnet; turbo-molecular vacuum pumps for the "fish-eye" windows; the two superconducting coils; a handling platform; the two cryostats suspended from the bar of the travelling crane which has a 170 ton carrying capacity. The chamber proper, not dismantled, is inside the shielding.
Results from the MAC Vertex chamber
International Nuclear Information System (INIS)
Nelson, H.N.
1987-05-01
The design, construction, and performance characteristics of a high precision gaseous drift chamber made of thin walled proportional tubes are described. The device achieved an average spatial resolution of 45 μm in use for physics analysis with the MAC detector. The B-lifetime result obtained with this chamber is discussed
Measurement and Compensation of BPM Chamber Motion in HLS
Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.
2010-06-01
Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.
Measurement and Compensation of BPM Chamber Motion in HLS
International Nuclear Information System (INIS)
Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.
2010-01-01
Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.
Optical chirp z-transform processor with a simplified architecture.
Ngo, Nam Quoc
2014-12-29
Using a simplified chirp z-transform (CZT) algorithm based on the discrete-time convolution method, this paper presents the synthesis of a simplified architecture of a reconfigurable optical chirp z-transform (OCZT) processor based on the silica-based planar lightwave circuit (PLC) technology. In the simplified architecture of the reconfigurable OCZT, the required number of optical components is small and there are no waveguide crossings which make fabrication easy. The design of a novel type of optical discrete Fourier transform (ODFT) processor as a special case of the synthesized OCZT is then presented to demonstrate its effectiveness. The designed ODFT can be potentially used as an optical demultiplexer at the receiver of an optical fiber orthogonal frequency division multiplexing (OFDM) transmission system.
30 CFR 57.7807 - Flushing the combustion chamber.
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Flushing the combustion chamber. 57.7807... and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7807 Flushing the combustion chamber. The combustion chamber of a jet drill stem which has been sitting unoperated in a drill hole shall be...
Management of unconverted light for the National Ignition Facility target chamber
International Nuclear Information System (INIS)
Anderson, A. T.; Bletzer, K.; Burnham, A. K.; Dixit, S.; Genin, F. Y.; Hibbard, W.; Norton, J.; Scott, J. M.; Whitman, P. K.
1998-01-01
The NIF target chamber beam dumps must survive high x-ray, laser, ion, and shrapnel exposures without excessive generation of vapors or particulate that will contaminate the final optics debris shields, thereby making the debris shields susceptible to subsequent laser damage. The beam dumps also must be compatible with attaining and maintaining the required target chamber vacuum and must not activate significantly under high neutron fluxes. Finally, they must be developed, fabricated, and maintained for a reasonable cost. The primary challenge for the beam dump is to survive up to 20 J/cm 2 of lpm light and 1 - 2 J/cm 2 of nominally 200 - 350 eV blackbody temperature x rays. Additional threats include target shrapnel, and other contamination issues. Designs which have been evaluated include louvered hot-pressed boron carbide (B 4 C) or stainless steel (SS) panels, in some cases covered with transparent Teflon film, and various combinations of inexpensive low thermal expansion glasses backed by inexpensive absorbing glass. Louvered designs can recondense a significant amount of ablated material that would otherwise escape into the target chamber. Transparent Teflon was evaluated as an alternative way to capture ablated material. The thin Teflon sheet would need to be replaced after each shot since it exhibits both laser damage and considerable x- ray ablation with each shot. Uncontaminated B 4 C, SS, and low thermal expansion glasses have reasonably small x-ray and laser ablation rates, although the glasses begin to fail catastrophically after 100 high fluence shots. Commercially available absorbing glasses require a pre-shield of either Teflon or low thermal expansion glass to prevent serious degradation by the x-ray fluence. Advantages of the hot-pressed B 4 C and SS over glass are their performance against microshrapnel, their relative indifference to contamination, and their ability to be refurbished by aggressive cleaning using CO 2 pellets, glass beads, high
Time-driven activity based costing: a comparative study with the activity based costing
Directory of Open Access Journals (Sweden)
Marina Battistella Luna
2017-06-01
Full Text Available The activity-based costing (ABC emerged in the 1980s to meet the new necessities of cost information facing companies, the result of continuous changes in the business environment. In the 2000s, a new costing method, known as time-driven activity-based costing (TDABC was introduced in order to simplify the ABC. This paper compares these methods in order to provide information to assist managers to decide which of these methods better suits the reality of their companies. Therefore, they were analyzed based on information obtained through a systematic search in the Scopus and Web of Knowledge databases, as well as papers from the annals of the Congresso Brasileiro de Custos, Congresso de Controladoria e Contabilidade da USP and Encontro Nacional de Engenharia de Produção (considering scientific papers published between 2004 and 2016. From this analysis, in most cases it was concluded that TDABC is a simpler and more practical option than ABC. However, it was also apparent that managers, before choosing a particular method, must verify whether the conditions that enable its applicability exist.
Study and analysis of drift chamber parameters
International Nuclear Information System (INIS)
Martinez Laso, L.
1988-01-01
The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)
Tuned Chamber Core Panel Acoustic Test Results
Schiller, Noah H.; Allen, Albert R.
2016-01-01
This report documents acoustic testing of tuned chamber core panels, which can be used to supplement the low-frequency performance of conventional acoustic treatment. The tuned chamber core concept incorporates low-frequency noise control directly within the primary structure and is applicable to sandwich constructions with a directional core, including corrugated-, truss-, and fluted-core designs. These types of sandwich structures have long, hollow channels (or chambers) in the core. By adding small holes through one of the facesheets, the hollow chambers can be utilized as an array of low-frequency acoustic resonators. These resonators can then be used to attenuate low-frequency noise (below 400 Hz) inside a vehicle compartment without increasing the weight or size of the structure. The results of this test program demonstrate that the tuned chamber core concept is effective when used in isolation or combined with acoustic foam treatments. Specifically, an array of acoustic resonators integrated within the core of the panels was shown to improve both the low-frequency absorption and transmission loss of the structure in targeted one-third octave bands.
Timovsky, J.; Gankema, Paulien; Pierik, Ronald; Holzinger, Rupert
2014-01-01
A system of two plant chambers and a downstream reaction chamber has been set up to investigate the emission of biogenic volatile organic compounds (BVOCs) and possible effects of pollutants such as ozone. The system can be used to compare BVOC emissions from two sets of differently treated plants,
Directory of Open Access Journals (Sweden)
Mohiuddin Khan Shourav
2017-12-01
Full Text Available It is technically difficult to acquire large-field images under the complexity and cost restrictions of a diagnostic and instant field research purpose. The goal of the introduced large-field imaging system is to achieve a tolerable resolution for detecting microscale particles or objects in the entire image field without the field-curvature effect, while maintaining a cost-effective procedure and simple design. To use a single commercial lens for imaging a large field, the design attempts to fabricate a curved microfluidic chamber. This imaging technique improves the field curvature and distortion at an acceptable level of particle detection. This study examines Paramecium caudatum microswimmers to track their motion dynamics in different viscous media with imaging techniques. In addition, the study found that the average speed for P. caudatum was 60 µm/s, with a standard deviation of ±12 µm/s from microscopic imaging of the original medium of the sample, which leads to a variation of 20% from the average measurement. In contrast, from large-field imaging, the average speeds of P. caudatum were 63 µm/s and 68 µm/s in the flat and curved chambers, respectively, with the same medium viscosity. Furthermore, the standard deviations that were observed were ±7 µm/s and ±4 µm/s and the variations from the average speed were calculated as 11% and 5.8% for the flat and curved chambers, respectively. The proposed methodology can be applied to measure the locomotion of the microswimmer at small scales with high precision.
RF Anechoic Chambers, Tri-Service Research Laboratory
Federal Laboratory Consortium — In collaboration with the Navy, there are 12 RF Anechoic and static free exposure chambers located at TSRL. These chambers cover the majority of the RF spectrum and...
Energetic and economic cost of nuclear heat − impact on the cost of desalination
Directory of Open Access Journals (Sweden)
Dardour Saied
2017-01-01
Full Text Available An exploratory study has been carried out to evaluate the cost of heat supplied by a pressurized water reactor type of nuclear reactors to thermal desalination processes. In the context of this work, simplified models have been developed to describe the thermodynamics of power conversion, the energetics of multi-effect evaporation (MED, and the costs of electricity and heat cogenerated by the dual-purpose power plant. Application of these models show that, contrary to widespread belief, (nuclear-powered MED and seawater reverse osmosis are comparable in terms of energy effectiveness. Process heat can be produced, in fact, by a relatively small increase in the core power. As fuel represents just a fraction of the cost of nuclear electricity, the increase in fuel-related expenses is expected to have limited impact on power generation economics.
International Nuclear Information System (INIS)
Bryukhanov, N.S.; Galyaev, N.A.; Kotov, V.I.; Prosin, B.V.; Romanov, Yu.A.; Khodyrev, Yu.S.
1980-01-01
A system of multiwire proportional chambers (MPC) operating on-line with a M-6000 computer used during tuning and monitoring of beam parameters in a separated particle channel for the Mirabelle bubble chamber is described. Peculiarities of the construction and main characteristics of two MPC versions are considered. The first version is intended for placing in a vacuum at the edges of high-frequency separator deflector, the second one - for placing outside a vacuum in ionoguide gaps. Power supply of the proportional chambers is carried out from local compact (160x95x50 mm) high-voltage sources remotely controlled from a channel panel by low voltage. A MPC position diagram in the accelerator channel, flowsheet of registering electronics for the MPC system, main circuits of high-voltage power source, analog-to-digital converter of a code and trunk amplifier are given. A graph of amplifier signal amplitude dependence on high voltage of a chamber for a different composition of a gaseous mixture is presented. It is noted that the used elements of the electronic system provide the reliable processing of data and its transmission for a great distance (approximately 400 m). It is underlined that the MPC system operation for a long time has shown its high efficiency and reliability
Monte Carlo modeling of ion chamber performance using MCNP.
Wallace, J D
2012-12-01
Ion Chambers have a generally flat energy response with some deviations at very low (2 MeV) energies. Some improvements in the low energy response can be achieved through use of high atomic number gases, such as argon and xenon, and higher chamber pressures. This work looks at the energy response of high pressure xenon-filled ion chambers using the MCNP Monte Carlo package to develop geometric models of a commercially available high pressure ion chamber (HPIC). The use of the F6 tally as an estimator of the energy deposited in a region of interest per unit mass, and the underlying assumptions associated with its use are described. The effect of gas composition, chamber gas pressure, chamber wall thickness, and chamber holder wall thicknesses on energy response are investigated and reported. The predicted energy response curve for the HPIC was found to be similar to that reported by other investigators. These investigations indicate that improvements to flatten the overall energy response of the HPIC down to 70 keV could be achieved through use of 3 mm-thick stainless steel walls for the ion chamber.
Life-cycle cost trade studies for hardness assurance
International Nuclear Information System (INIS)
Millward, D.G.
1996-01-01
Based on hardness assurance (HA) cost trade studies conducted on a low-cost/high-volume tactical military system with moderate radiation environments, conventional strategies for design hardening and HA can result in higher life-cycle costs (LCC) than alternate approaches. The trade studies used variables designed to investigate LCC as a function of several critical parameters, including semiconductor procurement option, system quantity, HA testing option,a nd other variables. An LCC model and sample problem are included to illustrate the key results. Following the results of the trade studies, limitations of the simplified cost model are presented, the relationship of these results to current procurement practices are discussed, and the application of the results to modern military and commercial systems is discussed
International Nuclear Information System (INIS)
Qin Zhonghua; Wu Linghui; Liu Jianbei; Chinese Academy of Sciences, Beijing; Yan Zhikang; Hunan Univ., Changsha; Chen Yuanbo; Chen Chang; Xu Meihang; Wang Lan; Ma Xiaoyan; Jin Yan; Liu Rongguang; Tang Xiao; Zhang Guifang; Zhu Qiming; Sheng Huayi; Zhu Kejun
2007-01-01
A full-length prototype of the BESIII drift chamber was built. The experience gained on gas sealing, high voltage supply and front-end electronics installation should be greatly beneficial to the successful construction of the BESIII drift chamber. An on-detector test of the BESIII drift chamber electronics was carried out with the constructed prototype chamber. The noise performance, drift time and charge measurements, and electronics gains were examined specifically. The final test results indicate that the electronics have a good performance and can satisfy their design requirements. (authors)
Simplified distributed parameters BWR dynamic model for transient and stability analysis
International Nuclear Information System (INIS)
Espinosa-Paredes, Gilberto; Nunez-Carrera, Alejandro; Vazquez-Rodriguez, Alejandro
2006-01-01
This paper describes a simplified model to perform transient and linear stability analysis for a typical boiling water reactor (BWR). The simplified transient model was based in lumped and distributed parameters approximations, which includes vessel dome and the downcomer, recirculation loops, neutron process, fuel pin temperature distribution, lower and upper plenums reactor core and pressure and level controls. The stability was determined by studying the linearized versions of the equations representing the BWR system in the frequency domain. Numerical examples are used to illustrate the wide application of the simplified BWR model. We concluded that this simplified model describes properly the dynamic of a BWR and can be used for safety analysis or as a first approach in the design of an advanced BWR
Final report for NIF chamber dynamics studies
International Nuclear Information System (INIS)
Burnham, A; Peterson, P F; Scott, J M
1998-01-01
The National Ignition Facility (NIF), a 1.8 MJ, 192 laser beam facility, will have anticipated fusion yields of up to 20 MJ from D-T pellets encased in a gold hohlraum target. The energy emitted from the target in the form of x rays, neutrons, target debris kinetic energy, and target shrapnel will be contained in a 5 m. radius spherical target chamber. various diagnostics will be stationed around the target at varying distances from the target. During each shot, the target will emit x rays that will vaporize nearby target facing surfaces including those of the diagnostics, the target positioner, and other chamber structures. This ablated vapor will be transported throughout the chamber, and will eventually condense and deposit on surfaces in the chamber, including the final optics debris shields. The research at the University of California at Berkeley relates primarily to the NIF chamber dynamics. The key design issues are the ablation of the chamber structures, transport of the vapor through the chamber and the condensation or deposition processes of those vaporized materials. An understanding of these processes is essential in developing a concept for protecting the fina optics debris shields from an excessive coating (> 10 A) of target debris and ablated material, thereby prolonging their lifetime between change-outs. At Berkeley, we have studied the physical issues of the ablation process and the effects of varying materials, the condensation process of the vaporized material, and design schemes that can lower the threat posed to the debris shields by these processes. The work or portions of the work completed this year have been published in several papers and a dissertation [l-5
Simplified elastoplastic fatigue analysis
International Nuclear Information System (INIS)
Autrusson, B.; Acker, D.; Hoffmann, A.
1987-01-01
Oligocyclic fatigue behaviour is a function of the local strain range. The design codes ASME section III, RCC-M, Code Case N47, RCC-MR, and the Guide issued by PNC propose simplified methods to evaluate the local strain range. After having briefly described these simplified methods, we tested them by comparing the results of experimental strains with those predicted by these rules. The experiments conducted for this study involved perforated plates under tensile stress, notched or reinforced beams under four-point bending stress, grooved specimens under tensile-compressive stress, and embedded grooved beams under bending stress. They display a relative conservatism depending on each case. The evaluation of the strains of rather inaccurate and sometimes lacks conservatism. So far, the proposal is to use the finite element codes with a simple model. The isotropic model with the cyclic consolidation curve offers a good representation of the real equivalent strain. There is obviously no question of representing the cycles and the entire loading history, but merely of calculating the maximum variation in elastoplastic equivalent deformations with a constant-rate loading. The results presented testify to the good prediction of the strains with this model. The maximum equivalent strain will be employed to evaluate fatigue damage
Proportional chambers and multiwire drift chambers at high rates
International Nuclear Information System (INIS)
Walenta, A.H.
1977-01-01
The high event and particle rates expected for ISABELLE intersecting storage rings raise the question whether PWC's and drift chambers, now widely in use in experiments, still can operate under such conditions. Various effects depend on the number of avalanches produced per length of wire N and the size of the avalanche Q, i.e., on the number of positive ions created in an avalanche. Therefore the important parameter for the following discussion is the product QN. The minimum Q is determined by the type and noise level of preamplifiers used. Examples are given for a typical low noise amplifier as well as for a typical integrated ''cheap'' amplifier. The rate/wire length N depends on the chamber arrangement, wire spacing, etc. In multiwire drift chambers, a single wire shows space-charge effects reducing the pulse height by 1% at a rate of N = 7 x 10 3 mm -1 sec -1 . At a rate of N approximately equal to 10 5 mm -1 sec -1 an efficiency loss of the order of 1% was noticed. The aging effect due to deposits on the anode wire can be reduced using low noise amplifiers and low gas gain to such an extent that a lifetime of about half a year at ISABELLE can be expected. The use of conventional cheap preamplifiers will result in a typical lifetime of about 30 days. Improvements are probable. The time resolution of Δt/sub r/ = 4 nsec fwhm seems adequate for event rates of 10 7 sec -1 . The memory time Δt/sub m/ greater than or equal to 100 nsec may cause serious problems for pattern recognition depending on layout and readout. The use of induced signals on cathode pads, thus reading out shorter parts of the wire, can solve the problem
Track photographing in 8-m streamer chamber
International Nuclear Information System (INIS)
Anisimova, N.Z.; Davidenko, V.A.; Kantserov, V.A.; Rybakov, V.G.; Somov, S.V.
1981-01-01
A system for obtaining data from a streamer chamber intended for measuring muon polarization is described. An optical scheme for photographing of tracks in the chamber is given. The photographing process is complicated at the expense of large dimensions and module structure of the chamber as well as due to insufficient for direct photographing brightness of streamers. The system described was tested during a long time in a physical experiment. More than 100 thousand photos have been taken by its means [ru
Calibration of working standard ionization chambers and dose standardization
International Nuclear Information System (INIS)
Abd Elmahoud, A. A. B.
2011-01-01
Measurements were performed for the calibration of two working standard ionization chambers in the secondary standard dosimetry laboratory of Sudan. 600 cc cylindrical former type and 1800 cc cylindrical radical radiation protection level ionization chambers were calibrated against 1000 cc spherical reference standard ionization chamber. The chamber were calibrated at X-ray narrow spectrum series with beam energies ranged from (33-116 KeV) in addition to 1''3''7''Cs beam with 662 KeV energy. The chambers 0.6 cc and 0.3 cc therapy level ionization were used for dose standardization and beam output calibrations of cobalt-60 radiotherapy machine located at the National Cancer Institute, University of Gazira. Concerning beam output measurements for 6''0''Co radiotherapy machine, dosimetric measurements were performed in accordance with the relevant per IAEA dosimetry protocols TRS-277 and TRS-398. The kinetic energy released per unit mass in air (air kerma) were obtained by multiplying the corrected electrometer reading (nC/min) by the calibration factors (Gy/n C) of the chambers from given in the calibration certificate. The uncertainty of measurements of air kerma were calculated for the all ionization chambers (combined uncertainty) the calibration factors of these ionization chambers then were calculated by comparing the reading of air kerma of secondary standard ionization chambers to than from radical and farmer chambers. The result of calibration working standard ionization chambers showed different calibration factors ranged from 0.99 to 1.52 for different radiation energies and these differences were due to chambers response and specification. The absorbed dose to to water calculated for therapy ionization chamber using two code of practice TRS-277 and TRS-398 as beam output for 6''0''Co radiotherapy machine and it can be used as a reference for future beam output calibration in radiotherapy dosimetry. The measurement of absorbed dose to water showed that the
Measuring the sensitivity of a boron-lined ion chamber
International Nuclear Information System (INIS)
Barton, D.M.
1992-03-01
Boron-lined ion chambers are used to monitor external neutron flux from fissionable materials assembled at the Los Alamos Critical Assembly Experiment Facility. The sensitivity of these chambers must be measured periodically in order to detect changes in filling gas and to evaluate other factors that may affect chamber performance. We delineate a procedure to measure ion chamber response using a particular neutron source ( 239 PuBe) in a particular moderating geometry of polyethylene. We also discuss use of the amplifier, high-voltage power supply, recorders, and scram circuits that comprise the complete ion chamber monitoring system
GBO RF Anechoic Chamber & Antenna Test Range
Federal Laboratory Consortium — A shielded anechoic chamber measuring 15 by 15 by 37 feet is located in the Jansky Laboratory at Green Bank. This chamber has been outfitted as a far-field antenna...
Safety shield for vacuum/pressure-chamber windows
Shimansky, R. A.; Spencer, R.
1980-01-01
Optically-clear shatter-resistant safety shield protects workers from implosion and explosion of vacuum and pressure windows. Plastic shield is inexpensive and may be added to vacuum chambers, pressure chambers, and gas-filling systems.
A simplified approach for the computation of steady two-phase flow in inverted siphons.
Diogo, A Freire; Oliveira, Maria C
2016-01-15
Hydraulic, sanitary, and sulfide control conditions of inverted siphons, particularly in large wastewater systems, can be substantially improved by continuous air injection in the base of the inclined rising branch. This paper presents a simplified approach that was developed for the two-phase flow of the rising branch using the energy equation for a steady pipe flow, based on the average fluid fraction, observed slippage between phases, and isothermal assumption. As in a conventional siphon design, open channel steady uniform flow is assumed in inlet and outlet chambers, corresponding to the wastewater hydraulic characteristics in the upstream and downstream sewers, and the descending branch operates in steady uniform single-phase pipe flow. The proposed approach is tested and compared with data obtained in an experimental siphon setup with two plastic barrels of different diameters operating separately as in a single-barrel siphon. Although the formulations developed are very simple, the results show a good adjustment for the set of the parameters used and conditions tested and are promising mainly for sanitary siphons with relatively moderate heights of the ascending branch. Copyright © 2015 Elsevier Ltd. All rights reserved.
International Nuclear Information System (INIS)
Goto, S.; Ohmori, S.; Mori, M.
2005-01-01
It is possible to establish simplified system with reduced space and total equipment weight using high-efficiency Steam Injector (SI) instead of low-pressure feedwater heaters in Nuclear Power Plant (NPP)(1)-(6). The SI works as a heat exchanger through direct contact between feedwater from the condensers and extracted steam from the turbines. It can get a higher pressure than supplied steam pressure, so it can reduce the feedwater pumps. The maintenance and reliability are still higher because SI has no movable parts. This paper describes the analysis of the heat balance and plant efficiency of this Innovative- Simplified NPP with high-efficiency SI. The plant efficiency is compared with the electric power of 1100MWe-class BWR system and the Innovative- Simplified BWR system with SI. The SI model is adapted into the heat balance simulator with a simplified model. The results show plant efficiencies of the Innovated-Simplified BWR system are almost equal to the original BWR one. The present research is one of the projects that are carried out by Tokyo Electric Power Company, Toshiba Corporation, and six Universities in Japan, funded from the Institute of Applied Energy (IAE) of Japan as the national public research-funded program. (authors)
Developing Cloud Chambers with High School Students
Ishizuka, Ryo; Tan, Nobuaki; Sato, Shoma; Zeze, Syoji
The result and outcome of the cloud chamber project, which aims to develop a cloud chamber useful for science education is reported in detail. A project includes both three high school students and a teacher as a part of Super Science High School (SSH) program in our school. We develop a dry-ice-free cloud chamber using salt and ice (or snow). Technical details of the chamber are described. We also argue how the project have affected student's cognition, motivation, academic skills and behavior. The research project has taken steps of professional researchers, i.e., in planning research, applying fund, writing a paper and giving a talk in conferences. From interviews with students, we have learnt that such style of scientific activity is very effective in promoting student's motivation for learning science.
The Impedance of Multi-layer Vacuum Chambers
Vos, L
2003-01-01
Many components of the LHC vacuum chamber have multi-layered walls : the copper coated cold beam screen, the titanium coated ceramic chamber of the dump kickers, the ceramic chamber of the injection kickers coated with copper stripes, only to name a few. Theories and computer programs are available for some time already to evaluate the impedance of these elements. Nevertheless, the algorithm developed in this paper is more convenient in its application and has been used extensively in the design phase of multi-layer LHC vacuum chamber elements. It is based on classical transmission line theory. Closed expressions are derived for simple layer configurations, while beam pipes involving many layers demand a chain calculation. The algorithm has been tested with a number of published examples and was verified with experimental data as well.
Yu, Jianchun; Wu, Guohao; Tang, Yun; Ye, Yingjiang; Zhang, Zhongtao
2017-08-01
Parenteral nutrition (PN) covering the need for carbohydrates, amino acids, and lipids can either be compounded from single nutrients or purchased as an industrially manufactured ready-to-use regimen. This study compares a commercially available 3-chamber bag (study group) with a conventionally compounded monobag regarding nutrition efficacy, safety, and regimen preparation time. This prospective, randomized, single-blind study was conducted at 5 Chinese hospitals from October 2010-October 2011. Postsurgical patients requiring PN for at least 6 days were randomly assigned to receive the study or control regimen. Plasma concentrations of prealbumin and C-reactive protein (CRP), regimen preparation time, length of hospital stay (LOS), 30-day mortality, safety laboratory parameters, and adverse events (AEs) were recorded. In total, 240 patients (121 vs 119 in study and control groups) participated in this study. Changes in prealbumin concentrations during nutrition support (Δ Prealb(StudyGroup) = 2.65 mg/dL, P < .001 vs Δ Prealb(ControlGroup) = 0.27 mg/dL, P = .606) and CRP values were comparable. Regimen preparation time was significantly reduced in the study group by the use of 3-chamber bags (t (StudyGroup) = 4.90 ± 4.41 minutes vs t (ControlGroup) = 12.13 ± 5.62 minutes, P < .001). No differences were detected for LOS, 30-day mortality, safety laboratory parameters, and postoperative AEs (37 vs 38 in study and control groups). The PN regimen provided by the 3-chamber bag was comparable to the compounded regimen and safe in use. Time savings during regimen preparation indicates that use of 3-chamber bags simplifies the process of regimen preparation.
Hydrostatic Hyperbaric Chamber Ventilation System
Sarguisingh, Miriam J.
2012-01-01
The hydrostatic hyperbaric chamber (HHC) represents the merger of several technologies in development for NASA aerospace applications, harnessed to directly benefit global health. NASA has significant experience developing composite hyperbaric chambers for a variety of applications. NASA also has researched the application of water-filled vessels to increase tolerance of acceleration forces. The combination of these two applications has resulted in the hydrostatic chamber, which has been conceived as a safe, affordable means of making hyperbaric oxygen therapy (HBOT) available in the developing world for the treatment of a variety of medical conditions. Specifically, HBOT is highly-desired as a possibly curative treatment for Buruli Ulcer, an infectious condition that afflicts children in sub-Saharan Africa. HBOT is simply too expensive and too dangerous to implement in the developing world using standard equipment. The HHC technology changes the paradigm. The HHC differs from standard hyperbaric chambers in that the majority of its volume is filled with water which is pressurized by oxygen being supplied in the portion of the chamber containing the patient s head. This greatly reduces the amount of oxygen required to sustain a hyperbaric atmosphere, thereby making the system more safe and economical to operate. An effort was taken to develop an HHC system to apply HBOT to children that is simple and robust enough to support transport, assembly, maintenance and operation in developing countries. This paper details the concept for an HHC ventilation and pressurization system to provide controlled pressurization and adequate washout of carbon dioxide while the subject is enclosed in the confined space during the administration of the medical treatment. The concept took into consideration operational complexity, safety to the patient and operating personnel, and physiological considerations. The simple schematic, comprised of easily acquired commercial hardware
Laboratory implantation for well type ionization chambers calibration
International Nuclear Information System (INIS)
Vianello, E.A.; Dias, D.J.; Almeida, C.E. de
1998-01-01
The Radiological Science Laboratory is implanting a service for calibration of well type chambers by IAEA training program. The kerma rate in the air (mu Gy/h) of the linear Cs-137 reference source CDCS-J4 have been determined using a well type chamber Standard Imaging HDR-1000 model, which have been calibrated at Secondary Standard Laboratory Calibration of IAEA, whereas two HDR-1000 Plus chambers were calibrated too, following the same standards. The results were compared with Wisconsin University calibration certification and has demonstrated that well type ionization chamber calibration can be used in brachytherapy for several kinds of radionuclides. (Author)
Shock tubes: compressions in the low pressure chamber
International Nuclear Information System (INIS)
Schins, H.; Giuliani, S.
1986-01-01
The gas shock tube used in these experiments consists of a low pressure chamber and a high pressure chamber, divided by a metal-diaphragm-to-rupture. In contrast to the shock mode of operation, where incident and reflected shocks in the low pressure chamber are studied which occur within 3.5 ms, in this work the compression mode of operation was studied, whose maxima occur (in the low pressure chamber) about 9 ms after rupture. Theoretical analysis was done with the finite element computer code EURDYN-1M, where the computation was carried out to 30 ms
Simple structure diffusion cloud chamber for educational purpose
International Nuclear Information System (INIS)
Hrehuss, Gy.; Molnar, B.
1982-01-01
A simple structure diffusion cloud chamber was designed and built with educational aim. The source of alpha particles is Am-241 radioisotope smeared on steel foil, the source of vapor is a felt disc saturated with methanol. Five minutes after covering the chamber the system achieves the thermodynamic equilibrium and alpha particle tracks of 5 cm length become visible in the centre of the chamber. Life-time of a track is about 0.5-1 second, the frequency is 2-3 tracks/s. The presented diffusion chamber can be built simply and easily, using cheap common materials and components. (D.Gy.)
Simplified Chua's attractor via bridging a diode pair
Directory of Open Access Journals (Sweden)
Quan Xu
2015-04-01
Full Text Available In this paper, a simplified Chua's circuit is realised by bridging a diode pair between a passive LC (inductance and capacitance in parallel connection - LC oscillator and an active RC (resistance and capacitance in parallel connection - RC filter. The dynamical behaviours of the circuit are investigated by numerical simulations and verified by experimental measurements. It is found that the simplified Chua's circuit generates Chua's attractors similarly and demonstrates complex non-linear phenomena including coexisting bifurcation modes and coexisting attractors in particular.
Effects of air humidity on ionization chamber response
International Nuclear Information System (INIS)
Meger, C.; DeLuca, P.M. Jr.; Pearson, D.W.; Venci, R.
1983-01-01
A study of the effect of air humidity on four different ionization chamber cap materials verified earlier studies (Kristensen and Sundbom, 1981; Mijnheer et al., 1983) and extended our understanding of the problem. We found nylon and A-150 plastic caps swell as they absorb water from the air. This accounts for as much as 2.5% increase in ionization response. Graphite chambers readily absorb and desorb water from the air. This creates a problem in maintaining dry air in a wet graphite chamber. Humid air has a different density and W value than dry air (Niatel, 1969, 1975). This decreases the charge collected in a wet graphite chamber. We observe a decrease in response of approximately 2%, a value greater than can be accounted for by these effects alone. Polyethylene chambers are unaffected by humid air. 4 refs., 9 figs
Charpak hemispherical wire chamber
1970-01-01
pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.
McFedries, Paul
2015-01-01
Learn Windows 10 quickly and painlessly with this beginner's guide Windows 10 Simplified is your absolute beginner's guide to the ins and outs of Windows. Fully updated to cover Windows 10, this highly visual guide covers all the new features in addition to the basics, giving you a one-stop resource for complete Windows 10 mastery. Every page features step-by-step screen shots and plain-English instructions that walk you through everything you need to know, no matter how new you are to Windows. You'll master the basics as you learn how to navigate the user interface, work with files, create
Marmel, Elaine
2013-01-01
A basic introduction to learn Office 2013 quickly, easily, and in full color Office 2013 has new features and tools to master, and whether you're upgrading from an earlier version or using the Office applications for the first time, you'll appreciate this simplified approach. Offering a clear, visual style of learning, this book provides you with concise, step-by-step instructions and full-color screen shots that walk you through the applications in the Microsoft Office 2013 suite: Word, Excel, PowerPoint, Outlook, and Publisher.Shows you how to tackle dozens of Office 2013
McFedries, Paul
2012-01-01
The easiest way for visual learners to get started with Windows 8 The popular Simplified series makes visual learning easier than ever, and with more than 360,000 copies sold, previous Windows editions are among the bestselling Visual books. This guide goes straight to the point with easy-to-follow, two-page tutorials for each task. With full-color screen shots and step-by-step directions, it gets beginners up and running on the newest version of Windows right away. Learn to work with the new interface and improved Internet Explorer, manage files, share your computer, and much more. Perfect fo
Sgambati, Antonella; Slenzka, Klaus; Schmeyers, Bernd; Di Capua, Massimiliano; Harting, Benjamin
Human exploration and permanent settlement on the Martian surface is the one of the most attractive and ambitious endeavors mankind has ever faced. As technology and research progress, solutions and information that were before unavailable are slowly making the dream become everyday more feasible. In the past years a huge amount of knowledge was gathered by the Mars Exploration Rovers Spirit and Opportunity and now, even more insight is being gathered through the latest rover of the family, Curiosity. In this work, data from the various missions will be used to define and reproduce on Earth the characteristic Martian atmospheric conditions. A small Mars environmental chamber has been designed and built with the objective of studying the effects of the Martian environment on biological systems. The Variable gravity Mars Environmental Chamber (VgMEC) will allow researchers to replicate atmospheric pressure, gas composition, temperature and UVA/B exposure typical of the equatorial regions of Mars. By exposing biological systems to a controllable set of stressor it will be possible to identify both multi and single stressor effects on the system of interest. While several Mars environment simulation facilities exist, due to their size and mass, all are confined to floor-fixed laboratory settings. The VgMEC is an OHB funded project that wishes to bring together the scientific community and the industry. Collaborations will be enabled by granting low cost access to cutting-edge instrumentation and services. Developed at OHB System AG, VgMEC has been designed from the ground up to be a 28L, compact and lightweight test volume capable of being integrated in existing centrifuges (such as the ESA-ESTEC LCD), gimbal systems and parabolic flight aircraft. The VgMEC support systems were designed to accommodate continuous operations of virtually unlimited duration through the adoption of solutions such as: hot swappable gas/liquid consumables bottles, low power requirements, an
Cloud chamber photographs of the cosmic radiation
Rochester, George Dixon
1952-01-01
Cloud Chamber Photographs of the Cosmic Radiation focuses on cloud chamber and photographic emulsion wherein the tracks of individual subatomic particles of high energy are studied. The publication first offers information on the technical features of operation and electrons and cascade showers. Discussions focus on the relationship in time and space of counter-controlled tracks; techniques of internal control of the cloud chamber; cascade processes with artificially-produced electrons and photons; and nuclear interaction associated with an extensive shower. The manuscript then elaborates on
"Flat-Fish" vacuum chamber for the ISR
CERN PhotoLab
1983-01-01
The "Flat-Fish" vacuum chamber was a very special one for the ISR beam intersection I-4, inside the Split-Field Magnet. Technical descriptions are given with pictures 7802042 and 7712182. There were several generations of this chamber. This picture was taken during the last year of ISR operation. See also 7510230X, 7511123X, 7802039, 7802041. A flat-fish type vacuum chamber was also used at I-8, inside the Open Axial Field Magnet (OAFM, experiment 807 on large transverse momentum collision products), see 7901358.
Growing and Analyzing Biofilms in Flow Chambers
DEFF Research Database (Denmark)
Tolker-Nielsen, Tim; Sternberg, Claus
2011-01-01
This unit describes the setup of flow chamber systems for the study of microbial biofilms, and methods for the analysis of structural biofilm formation. Use of flow chambers allows direct microscopic investigation of biofilm formation. The biofilms in flow chambers develop under hydrodynamic......, and disassembly and cleaning of the system. In addition, embedding and fluorescent in situ hybridization of flow chamber–grown biofilms are addressed. Curr. Protoc. Microbiol. 21:1B.2.1-1B.2.17. © 2011 by John Wiley & Sons, Inc....
Ballistic-neutralized chamber transport of intense heavy ion beams
International Nuclear Information System (INIS)
Rose, D.V.; Welch, D.R.; Oliver, B.V.; Clark, R.E.; Sharp, W.M.; Friedman, A.
2001-01-01
Two-dimensional particle-in-cell simulations of intense heavy ion beams propagating in an inertial confinement fusion (ICF) reactor chamber are presented. The ballistic-neutralized transport scheme studied uses 4 GeV Pb +1 ion beams injected into a low-density, gas-filled reactor chamber and the beam is ballistically focused onto an ICF target before entering the chamber. Charge and current neutralization of the beam is provided by the low-density background gas. The ballistic-neutralized simulations include stripping of the beam ions as the beam traverses the chamber as well as ionization of the background plasma. In addition, a series of simulations are presented that explore the charge and current neutralization of the ion beam in an evacuated chamber. For this vacuum transport mode, neutralizing electrons are only drawn from sources near the chamber entrance
CFD Modeling of Chamber Filling in a Micro-Biosensor for Protein Detection.
Islamov, Meiirbek; Sypabekova, Marzhan; Kanayeva, Damira; Rojas-Solórzano, Luis
2017-10-03
Tuberculosis (TB) remains one of the main causes of human death around the globe. The mortality rate for patients infected with active TB goes beyond 50% when not diagnosed. Rapid and accurate diagnostics coupled with further prompt treatment of the disease is the cornerstone for controlling TB outbreaks. To reduce this burden, the existing gap between detection and treatment must be addressed, and dedicated diagnostic tools such as biosensors should be developed. A biosensor is a sensing micro-device that consists of a biological sensing element and a transducer part to produce signals in proportion to quantitative information about the binding event. The micro-biosensor cell considered in this investigation is designed to operate based on aptamers as recognition elements against Mycobacterium tuberculosis secreted protein MPT64, combined in a microfluidic-chamber with inlet and outlet connections. The microfluidic cell is a miniaturized platform with valuable advantages such as low cost of analysis with low reagent consumption, reduced sample volume, and shortened processing time with enhanced analytical capability. The main purpose of this study is to assess the flooding characteristics of the encapsulated microfluidic cell of an existing micro-biosensor using Computational Fluid Dynamics (CFD) techniques. The main challenge in the design of the microfluidic cell lies in the extraction of entrained air bubbles, which may remain after the filling process is completed, dramatically affecting the performance of the sensing element. In this work, a CFD model was developed on the platform ANSYS-CFX using the finite volume method to discretize the domain and solving the Navier-Stokes equations for both air and water in a Eulerian framework. Second-order space discretization scheme and second-order Euler Backward time discretization were used in the numerical treatment of the equations. For a given inlet-outlet diameter and dimensions of an in-house built cell chamber
A Customizable Chamber for Measuring Cell Migration.
Chowdhury, Aniqa N; Vo, Huu Tri; Olang, Sharon; Mappus, Elliott; Peterson, Brian; Hlavac, Nora; Harvey, Tyler; Dean, Delphine
2017-03-12
Cell migration is a vital part of immune responses, growth, and wound healing. Cell migration is a complex process that involves interactions between cells, the extracellular matrix, and soluble and non-soluble chemical factors (e.g., chemoattractants). Standard methods for measuring the migration of cells, such as the Boyden chamber assay, work by counting cells on either side of a divider. These techniques are easy to use; however, they offer little geometric modification for different applications. In contrast, microfluidic devices can be used to observe cell migration with customizable concentration gradients of soluble factors 1 , 2 . However, methods for making microfluidics based assays can be difficult to learn. Here, we describe an easy method for creating cell culture chambers to measure cell migration in response to chemical concentration gradients. Our cell migration chamber method can create different linear concentration gradients in order to study cell migration for a variety of applications. This method is relatively easy to use and is typically performed by undergraduate students. The microchannel chamber was created by placing an acrylic insert in the shape of the final microchannel chamber well into a Petri dish. After this, poly(dimethylsiloxane) (PDMS) was poured on top of the insert. The PDMS was allowed to harden and then the insert was removed. This allowed for the creation of wells in any desired shape or size. Cells may be subsequently added to the microchannel chamber, and soluble agents can be added to one of the wells by soaking an agarose block in the desired agent. The agarose block is added to one of the wells, and time-lapse images can be taken of the microchannel chamber in order to quantify cell migration. Variations to this method can be made for a given application, making this method highly customizable.
Test chamber for alpha spectrometry
Larsen, Robert P.
1977-01-01
Alpha emitters for low-level radiochemical analysis by measurement of alpha spectra are positioned precisely with respect to the location of a surface-barrier detector by means of a chamber having a removable threaded planchet holder. A pedestal on the planchet holder holds a specimen in fixed engagement close to the detector. Insertion of the planchet holder establishes an O-ring seal that permits the chamber to be pumped to a desired vacuum. The detector is protected against accidental contact and resulting damage.
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers
Ferretti, Claudio; The ATLAS collaboration
2015-01-01
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one working day and the sense wire positioning accuracy improved by a factor of two to better than ten microns. Two sMDT chambers have been installed in ATLAS in 2014 to improve the momentum resolution in the barrel part of the spectrometer. The construction of additional twelve chambers covering the feet regions of the ATLAS detector has started. It will be followed by the replacement of the MDT chambers at the ends of the barrel inner layer by sMDTs improving the Performance at the high expected background rates and providing space for additional RPC trigger chambers.
Upgrades of the ATLAS Muon Spectrometer with sMDT Chambers
Ferretti, C
2016-01-01
With half the drift-tube diameter of the Monitored Drift Tube (MDT) chambers of the ATLAS muon spectrometer and otherwise unchanged operating parameters, small-diameter Muon Drift Tube (sMDT) chambers provide an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit. The chamber assembly time has been reduced by a factor of seven to one working day and the sense wire positioning accuracy improved by a factor of two to better than ten microns. Two sMDT chambers have been installed in ATLAS in 2014 to improve the momentum resolution in the barrel part of the spectrometer. The construction of an additional twelve chambers covering the feet regions of the ATLAS detector has started. It will be followed by the replacement of the MDT chambers at the ends of the barrel inner layer by sMDTs improving the Performance at the high expected background rates and providing space for additional RPC trigger chambers.
Utilizing Chamber Data for Developing and Validating Climate Change Models
Monje, Oscar
2012-01-01
Controlled environment chambers (e.g. growth chambers, SPAR chambers, or open-top chambers) are useful for measuring plant ecosystem responses to climatic variables and CO2 that affect plant water relations. However, data from chambers was found to overestimate responses of C fluxes to CO2 enrichment. Chamber data may be confounded by numerous artifacts (e.g. sidelighting, edge effects, increased temperature and VPD, etc) and this limits what can be measured accurately. Chambers can be used to measure canopy level energy balance under controlled conditions and plant transpiration responses to CO2 concentration can be elucidated. However, these measurements cannot be used directly in model development or validation. The response of stomatal conductance to CO2 will be the same as in the field, but the measured response must be recalculated in such a manner to account for differences in aerodynamic conductance, temperature and VPD between the chamber and the field.
Thermal barrier coatings (TBC's) for high heat flux thrust chambers
Bradley, Christopher M.
The last 30 years materials engineers have been under continual pressure to develop materials with a greater temperature potential or to produce configurations that can be effectively cooled or otherwise protected at elevated temperature conditions. Turbines and thrust chambers produce some of the harshest service conditions for materials which lead to the challenges engineers face in order to increase the efficiencies of current technologies due to the energy crisis that the world is facing. The key tasks for the future of gas turbines are to increase overall efficiencies to meet energy demands of a growing world population and reduce the harmful emissions to protect the environment. Airfoils or blades tend to be the limiting factor when it comes to the performance of the turbine because of their complex design making them difficult to cool as well as limitations of their thermal properties. Key tasks for space transportation it to lower costs while increasing operational efficiency and reliability of our space launchers. The important factor to take into consideration is the rocket nozzle design. The design of the rocket nozzle or thrust chamber has to take into account many constraints including external loads, heat transfer, transients, and the fluid dynamics of expanded hot gases. Turbine engines can have increased efficiencies if the inlet temperature for combustion is higher, increased compressor capacity and lighter weight materials. In order to push for higher temperatures, engineers need to come up with a way to compensate for increased temperatures because material systems that are being used are either at or near their useful properties limit. Before thermal barrier coatings were applied to hot-section components, material alloy systems were able to withstand the service conditions necessary. But, with the increased demand for performance, higher temperatures and pressures have become too much for those alloy systems. Controlled chemistry of hot
Irradiation chamber for photoactivation patient treatment system
International Nuclear Information System (INIS)
Lee, K.H.; Troutner, V.H.; Goss, J.; King, M.J.
1988-01-01
A flat plate irradiation chamber is described for use in a patient treatment system for altering cells, including treating the cells with a photoactivatable agent and passing the cells and the agent through a field of photoactivating radiation whereby the agent is caused to be activated and to affect the cells. The agent and the cells are contained in the irradiation chamber during irradiation. The flat plate irradiation chamber comprises: a rigid top sheet matably joined with a rigid bottom sheet, forming therebetween a rigid serpentine pathway for conducting the cells through the field of radiation; and pump block means for holding tubing means in fluid communication with the serpentine pathway and adapted for engaging a peristaltic pump whereby rotation of the pump causes the cells to flow through the serpentine pathway, and wherein the chamber is removable from the system and disposable
Ultrasonic cleaning of electrodes of wire chambers
International Nuclear Information System (INIS)
Krasnov, V.A.; Kurepin, A.B.; Razin, V.I.
1980-01-01
A technological process of cleaning electrodes and working volume surfaces of wire chambers from contaminations by the simultaneous mechanical action of the energy of ultrasonic oscillations and the chemical action of detergents is discussed. A device for cleaning wire electrodes of proportional chambers of 0.3x0.4 m is described. The device uses two ultrasonic generators with a total power of 0.5 kW. As a detergent use is made of a mixture of ethyl alcohol, gasoline and freon. In the process of cleaning production defects can be detected in the wire chambers which makes it possible to timely remove the defects. Measurements of the surface resistance of fiberglass laminate of printed drift chamber electrodes at a voltage of 2 kV showed that after completing the cleaning process the resistance increases 15-20%
High-vacuum chamber for the irradiation of targets
International Nuclear Information System (INIS)
Krimmel, E.; Dullnig, H.
1975-01-01
The high vacuum chamber for irradiating targets with X-rays, electron or ion beams is connected to a magazine storage vessel for the targets through a loading duct which can be evacuated. This duct is traversed by a carriage transporting a magazine to the irradiation position. The duct can be closed by a closing valve. Inside the chamber there is a grip attached to a swivel arm which takes a frame with a target from the magazine, or vice versa, and moves it into the irradiation position. This means that the chamber must always be kept at a constant internal pressure. The swiveling shaft for the swivel arm and the transport pinion of the carriage in addition are magnetically coupled to drive shafts located outside the chamber, which obviates the need for any seals. The grip may also deposit the frame on a goniometer, which allows the target to be aligned in the irradiation position. In addition, the measuring probes used to record the amount of reflected radiation are installed in the chamber under electrically insulated conditions relative to the chamber. (DG/RF) [de
Multi-chamber nucleic acid amplification and detection device
Dugan, Lawrence
2017-10-25
A nucleic acid amplification and detection device includes an amplification cartridge with a plurality of reaction chambers for containing an amplification reagent and a visual detection reagent, and a plurality of optically transparent view ports for viewing inside the reaction chambers. The cartridge also includes a sample receiving port which is adapted to receive a fluid sample and fluidically connected to distribute the fluid sample to the reaction chamber, and in one embodiment, a plunger is carried by the cartridge for occluding fluidic communication to the reaction chambers. The device also includes a heating apparatus having a heating element which is activated by controller to generate heat when a trigger event is detected. The heating apparatus includes a cartridge-mounting section which positioned a cartridge in thermal communication with the heating element so that visual changes to the contents of the reaction chambers are viewable through the view ports.
One cubic metre NIST traceable radon test chamber
International Nuclear Information System (INIS)
Kotrappa, P.; Stieff, F.
2008-01-01
With the availability of the National Inst. of Standards and Technology (NIST) Radon Emanation Standard with a content of ∼5000 Bq of 226 Ra, it is possible to build a flow through a practical radon test chamber. A standard glove box with four gloves and a transfer port is used. Air is pumped through a flow integrator, water jar for humidification and NIST source holder, and into the glove box through a manifold. A derived theoretical expression provides the calculated radon concentration inside the chamber. The calculation includes a derived decay correction due to the large volume and low flow rate of the system. Several calibrated continuous radon monitors and passive integrating electret ion chambers tested in the chamber agreed fairly well with the calculated radon concentrations. The chamber is suitable for handling the calibration of several detectors at the same time. (authors)
General purpose nuclear irradiation chamber
International Nuclear Information System (INIS)
Nurul Fadzlin Hasbullah; Nuurul Iffah Che Omar; Nahrul Khair Alang Md Rashid; Jaafar Abdullah
2013-01-01
Nuclear technology has found a great need for use in medicine, industry, and research. Smoke detectors in our homes, medical treatments and new varieties of plants by irradiating its seeds are just a few examples of the benefits of nuclear technology. Portable neutron source such as Californium-252, available at Industrial Technology Division (BTI/ PAT), Malaysian Nuclear Agency, has a 2.645 year half-life. However, 252 Cf is known to emit gamma radiation from the source. Thus, this chamber aims to provide a proper gamma shielding for samples to distinguish the use of mixed neutron with gamma-rays or pure neutron radiation. The chamber is compatible to be used with other portable neutron sources such as 241 Am-Be as well as the reactor TRIGA PUSPATI for higher neutron dose. This chamber was designed through a collaborative effort of Kulliyyah Engineering, IIUM with the Industrial Technology Division (BTI) team, Malaysian Nuclear Agency. (Author)
Rapid-Cycling Bubble-Chamber, details
CERN PhotoLab
1980-01-01
Parts of the hydraulic expansion system of the Rapid-Cycling Bubble-Chamber (RCBC). RCBC was the largest of 3 rapid-cycling bubble-chambers (the others were LEBC and HOLEBC), used as target- and vertex-detectors within the European Hybrid Spectrometer (EHS) in the SPS North Area (EHN1). RCBC contained 250 l of liquid hydrogen and was located inside a 3 T superconducting magnet. It was designed for 30 expansions/s (100 times faster than BEBC), the system shown here allowed 50 expansions/s. RCBC operated from 1981 to 1983 for experiments NA21, NA22 and NA23 at a rate of 15 expansions/s, clocking up a total of over 4 million. In the rear, at left, is bearded Lucien Veillet; Augustin Didona is at the right. See also 8001009. The installation of the piston assembly in the RCBC chamber body is shown in the Annual Report 1980, p.65.
Holography in small bubble chambers
International Nuclear Information System (INIS)
Lecoq, P.
1984-01-01
This chapter reports on an experiment to determine the total charm cross section at different incident momenta using the small, heavy liquid bubble chamber HOBC. Holography in liquid hydrogen is also tested using the holographic lexan bubble chamber HOLEBC with the aim of preparing a future holographic experiment in hydrogen. The high intensity tests show that more than 100 incident tracks per hologram do not cause a dramatic effect on the picture quality. Hydrogen is more favorable than freon as the bubble growth is much slower in hydrogen. An advantage of holography is to have the maximum resolution in the full volume of the bubble chamber, which allows a gain in sensitivity by a factor of 10 compared to classical optics as 100 tracks per hologram look reasonable. Holograms are not more difficult to analyze than classical optics high-resolution pictures. The results show that holography is a very powerful technique which can be used in very high resolution particle physics experiments
Inertial confinement fusion reaction chamber and power conversion system study. Final report
International Nuclear Information System (INIS)
Maya, I.; Schultz, K.R.; Bourque, R.F.
1985-10-01
This report summarizes the results of the second year of a two-year study on the design and evaluation of the Cascade concept as a commercial inertial confinement fusion (ICF) reactor. We developed a reactor design based on the Cascade reaction chamber concept that would be competitive in terms of both capital and operating costs, safe and environmentally acceptable in terms of hazard to the public, occupational exposure and radioactive waste production, and highly efficient. The Cascade reaction chamber is a double-cone-shaped rotating drum. The granulated solid blanket materials inside the rotating chamber are held against the walls by centrifugal force. The fusion energy is captured in a blanket of solid carbon, BeO, and LiAlO 2 granules. These granules are circulated to the primary side of a ceramic heat exchanger. Primary-side granule temperatures range from 1285 K at the LiAlO 2 granule heat exchanger outlet to 1600 K at the carbon granule heat exchanger inlet. The secondary side consists of a closed-cycle gas turbine power conversion system with helium working fluid, operating at 1300 K peak outlet temperature and achieving a thermal power conversion efficiency of 55%. The net plant efficiency is 49%. The reference design is a plant producing 1500 MW of D-T fusion power and delivering 815 MW of electrical power for sale to the utility grid. 88 refs., 44 figs., 47 tabs
Reconstruction of data in low-mass magnetostrictive chambers
International Nuclear Information System (INIS)
Daley, H.M.
1983-01-01
The reconstruction of spark positions in a set of low-mass spark chambers with remote magnetostrictive readout, used in a study of the reaction π - p → K 0 Λ, is described. The main detectors used were optical spark chambers but in order to provide information close to the vertices low-mass magnetostrictive chambers were fitted inside the cone of the superconducting polarised target magnet. (U.K.)
Drift chambers on the basis of Mylar tube blocks
Budagov, Yu.; Chirikov-Zorin, I.; Golovanov, L.; Khazins, D.; Kuritsin, A.; Pukhov, O.; Zhukov, V.
1993-06-01
Prototypes of drift chambers constructed of Mylar tube blocks were tested. The purpose of developing tube blocks technology was to create long chambers (up to 3-4 m). Counting and drift characteristics of the chambers for different values of the gas pressure and different diameters of sense wires are presented. The lifetime of the chambers is determined. A photoeffect in the visible spectrum on the surface of the thin film aluminium cathode, which covers the Mylar tubes was observed.
Drift chambers on the basis of Mylar tube blocks
International Nuclear Information System (INIS)
Budagov, Yu.; Chirikov-Zorin, I.; Golovanov, L.; Khazins, D.; Kuritsin, A.; Pukhov, U.; Zhukov, V.
1993-01-01
Prototypes of drift chambers constructed of Mylar tube blocks were tested. The purpose of developing tube blocks technology was to create chambers (up to 3-4 m). Counting and drift chracteristics of the chambers for different values of the gas pressure and different diameters of sense wires are presented. The lifetime of the chambers is determined. A photoeffect in the visible spectrum on the surface of the thin film aluminium cathode, which covers the Mylar tubes was observed. (orig.)
Corona discharge induced snow formation in a cloud chamber.
Ju, Jingjing; Wang, Tie-Jun; Li, Ruxin; Du, Shengzhe; Sun, Haiyi; Liu, Yonghong; Tian, Ye; Bai, Yafeng; Liu, Yaoxiang; Chen, Na; Wang, Jingwei; Wang, Cheng; Liu, Jiansheng; Chin, S L; Xu, Zhizhan
2017-09-18
Artificial rainmaking is in strong demand especially in arid regions. Traditional methods of seeding various Cloud Condensation Nuclei (CCN) into the clouds are costly and not environment friendly. Possible solutions based on ionization were proposed more than 100 years ago but there is still a lack of convincing verification or evidence. In this report, we demonstrated for the first time the condensation and precipitation (or snowfall) induced by a corona discharge inside a cloud chamber. Ionic wind was found to have played a more significant role than ions as extra CCN. In comparison with another newly emerging femtosecond laser filamentation ionization method, the snow precipitation induced by the corona discharge has about 4 orders of magnitude higher wall-plug efficiency under similar conditions.
Raymond J. Chambers--A Personal Reflection
Gaffikin, Michael
2012-01-01
This paper is presented as a tribute to Raymond J. Chambers. As its title suggests, it is a personal reflection through the eyes of someone who worked closely with him over a period of 10 years during a latter part of his career, and who completed a doctoral thesis with aspects of the work of Chambers as its subject. During this time, author…
Huang, M; Ibrahim, Md; Xia, B; Zou, Y
2011-08-01
Simplified cultivation technologies for rice have become increasingly attractive in recent years in China because of their social, economical and environmental benefits. To date, several simplified cultivation technologies, such as conventional tillage and seedling throwing (CTST), conventional tillage and direct seeding (CTDS), no-tillage and seedling throwing (NTST), no-tillage and direct seeding (NTDS) and no-tillage and transplanting (NTTP), have been developed in China. Most studies have shown that rice grown under each of these simplified cultivation technologies can produce a grain yield equal to or higher than traditional cultivation (conventional tillage and transplanting). Studies that have described the influences of agronomic practices on yield formation of rice under simplified cultivation have demonstrated that optimizing agronomy practices would increase the efficiencies of simplified cultivation systems. Further research is needed to optimize the management strategies for CTST, CTDS and NTST rice which have developed quickly in recent years, to strengthen basic research for those simplified cultivation technologies that are rarely used at present (such as NTTP and NTDS), to select and breed cultivars suitable for simplified cultivation and to compare the practicability and effectiveness of different simplified cultivation technologies in different rice production regions.
Assiro, R.; Cappelli, L.; Cascella, M.; De Lorenzis, L.; Grancagnolo, F.; Ignatov, F.; L'Erario, A.; Maffezzoli, A.; Miccoli, A.; Onorato, G.; Perillo, M.; Piacentino, G.; Rella, S.; Rossetti, F.; Spedicato, M.; Tassielli, G.; Zavarise, G.
2013-08-01
We present a novel low mass drift chamber concept, developed in order to fulfill the stringent requirements imposed by the experiments for extremely rare processes, which require high resolutions (order of 100-200 keV/c) for particle momenta in a range (50-100 MeV/c) totally dominated by the multiple scattering contribution. We describe a geometry optimization procedure and a new wiring strategy with a feed-through-less wire anchoring system developed and tested on a drift chamber prototype under completion at INFN-Lecce .
Five reasons to join local Chamber of Commerce and Industry
Verbovskii, Vladislav; Kosov, Vladimir; Chaika (Chayka), Yuliya Aleksandrovna
2016-01-01
The article describes five useful things that Chamber of Commerce and Industry membership may give to business owners after joining it. These things are the reasons to become a part of business community formed by Chambers of Commerce that may be considered by those business owner who are deciding whether to join Chamber of Commerce or not. Mentioned reasons are given with examples related to Tomsk Chamber of Commerce and Industry and are relevant to any Chamber of Commerce located in Russian...
Flexible geometry hodoscope using proportional chamber cathode read-out
International Nuclear Information System (INIS)
Aubret, C.; Bellefon, A. de; Benoit, P.; Brunet, J.M.; Tristram, G.
1978-01-01
The construction of a cathode read-out proportional chamber, used as a low mass hodoscope is described. Results on efficiency, time resolution and space resolution are shown. The associative logic, which permits the use of the chamber as a coplanarity chamber is briefly presented
Shielding Effectiveness Measurements using a Reverberation Chamber
Leferink, Frank Bernardus Johannes; Bergsma, J.G.; Bergsma, Hans; van Etten, Wim
2006-01-01
Shielding effectiveness measurements have been performed using a reverberation chamber. The reverberation chamber methodology as we1l as the measurement setup is described and some results are given. Samples include glass reinforced plastic panels, aluminum panels with many holes, wire mesh, among
SMOG@ctbp: simplified deployment of structure-based models in GROMACS.
Noel, Jeffrey K; Whitford, Paul C; Sanbonmatsu, Karissa Y; Onuchic, José N
2010-07-01
Molecular dynamics simulations with coarse-grained and/or simplified Hamiltonians are an effective means of capturing the functionally important long-time and large-length scale motions of proteins and RNAs. Structure-based Hamiltonians, simplified models developed from the energy landscape theory of protein folding, have become a standard tool for investigating biomolecular dynamics. SMOG@ctbp is an effort to simplify the use of structure-based models. The purpose of the web server is two fold. First, the web tool simplifies the process of implementing a well-characterized structure-based model on a state-of-the-art, open source, molecular dynamics package, GROMACS. Second, the tutorial-like format helps speed the learning curve of those unfamiliar with molecular dynamics. A web tool user is able to upload any multi-chain biomolecular system consisting of standard RNA, DNA and amino acids in PDB format and receive as output all files necessary to implement the model in GROMACS. Both C(alpha) and all-atom versions of the model are available. SMOG@ctbp resides at http://smog.ucsd.edu.
Integrability and solvability of the simplified two-qubit Rabi model
International Nuclear Information System (INIS)
Peng Jie; Ren Zhongzhou; Guo Guangjie; Ju Guoxing
2012-01-01
The simplified two-qubit Rabi model is proposed and its analytical solution is presented. There are no level crossings in the spectral graph of the model, which indicates that it is not integrable. The criterion of integrability for the Rabi model proposed by Braak (2011 Phys. Rev. Lett. 107 100401) is also used for the simplified two-qubit Rabi model and the same conclusion, consistent with what the spectral graph shows, can be drawn, which indicates that the criterion remains valid when applied to the two-qubit case. The simplified two-qubit Rabi model is another example of a non-integrable but exactly solvable system except for the generalized Rabi model. (paper)
Amplifier Design for Proportional Ionization Chambers
Energy Technology Data Exchange (ETDEWEB)
Baker, W. H.
1950-08-24
This paper presents the requirements of a nuclear amplifier of short resolving time, designed to accept pulses of widely varying amplitudes. Data are given which show that a proportional ionization chamber loaded with a 1,000-ohm resistor develops pulses of 0.5 microsecond duration and several volts amplitude. Results indicate that seven basic requirements are imposed on the amplifier when counting soft beta and gamma radiation in the presence of alpha particles, without absorbers. It should, (1) have a fast recovery time, (2) have a relatively good low frequency response, (3) accept pulses of widely varying heights without developing spurious pulsed, (4) have a limiting output stage, (5) preserve the inherently short rise time of the chamber, (6) minimize pulse integration, and (7) have sufficient gain to detect the weak pulses well below the chamber voltage at which continuous discharge takes place. The results obtained with an amplifier which meets these requirements is described. A formula is derived which indicates that redesign of the proportional ionization chamber might eliminate the need for an amplifier. This may be possible if the radioactive particles are collimated parallel to the collecting electrode.
Double chambered right ventricle
International Nuclear Information System (INIS)
Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung
1983-01-01
Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure
Double chambered right ventricle
Energy Technology Data Exchange (ETDEWEB)
Cho, Chul Koo; Yu, Yun Jeong; Yeon, Kyung Mo; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)
1983-12-15
Fourteen cases of double chambered right ventricle were diagnosed angiographically and of these nine cases were confirmed after operation and autopsy at Seoul National University Hospital in recent four years since 1979. The clinical and radiological findings with the emphasis on the cinecardiographic findings were analysed. The summaries of the analysis are as follows: 1. Among 14 cases, 6 cases were male and 8 cases were female. Age distribution was from 4 years to 36 years. 2. In chest x-ray findings, pulmonary vascularity was increased in 8 cases, decreased in 4 cases, and normal in 2 cases. Cardiomegaly was observed in 8 cases and other showed normal heart size. 3. In cinecardiography, 11 cases had interventricular septal defect. Among these 11 cases, VSD located in proximal high pressure chamber was in 2 cases and located in distal low pressure chamber was in 9 cases. 4. The location of aberrant muscle bundle in sinus portion of right ventricle was in 8 cases. In the rest 6 cases, the aberrant muscle bundle was located below the infundibulum of right ventricle. 5. For accurate diagnosis and differential diagnosis with other congenital cardiac anomalies such as Tetralogy of Fallot or isolated pulmonic stenosis, biplane cineangiography and catheterization is an essential procedure.
NEG coating of the non-standard LSS vacuum chambers
Costa-Pinto, P
2005-01-01
The vacuum chambers of nearly all the warm magnets of the LHC (MBXW, MQW, MSI, MSD, etc…) will be coated with a Ti-Zr-V thin film by magnetron sputtering. The NEG coating is necessary to provide uniform pumping speed along the chambers and to suppress electron cloud instabilities and dynamic outgassing. The about 300 chambers will be coated using the existing facility, developed for the production of the standard LSS chambers, after minor modifications mainly due to the different cross sections. In order to cope with the present installation schedule, the production planning will allow processing of different families of chambers in parallel by using two or three coating systems simultaneously. After a brief introduction to the Ti-Zr-V characteristics and performances, the coating facility and strategy will be illustrated as well as the possible conflicts due to uncertainties in the planning of the experimental beam pipes and the standard LSS chambers.
An ionization chamber with magnetic levitated electrodes
Kawaguchi, T
1999-01-01
A new type of ionization chamber which has magnetically levitated electrodes has been developed. The electrodes are supplied voltages for the repelling of ions by a battery which is also levitated with the electrodes. The characteristics of this ionization chamber are investigated in this paper.
Characteristic parameters of drift chambers calculation
International Nuclear Information System (INIS)
Duran, I.; Martinez-Laso, L.
1989-01-01
We present here the methods we used to analyse the characteristic parameters of drift chambers. The algorithms to calculate the electric potential in any point for any drift chamber geometry are presented. We include the description of the programs used to calculate the electric field, the drift paths, the drift velocity and the drift time. The results and the errors are discussed. (Author) 7 refs