WorldWideScience

Sample records for corrosion resistant alloys

  1. Corrosion resistance improvement of titanium base alloys

    Energy Technology Data Exchange (ETDEWEB)

    Popa, Mihai V.; Vasilescu, Ecaterina; Drob, Paula; Vasilescu, Cora; Drob, Silviu I., E-mail: ec_vasilescu@yahoo.co [Institute of Physical Chemistry ' Ilie Murgulescu' , Bucharest (Romania); Mareci, Daniel [Technical University ' Gh. Asachi' , Iasi (Romania); Rosca, Julia C. Mirza [Las Palmas de Gran Canaria University, Tafira (Spain). Mechanical Engineering Dept.

    2010-07-01

    The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy. (author)

  2. Corrosion resistance improvement of titanium base alloys

    Directory of Open Access Journals (Sweden)

    Mihai V. Popa

    2010-01-01

    Full Text Available The corrosion resistance of the new Ti-6Al-4V-1Zr alloy in comparison with ternary Ti-6Al-4V alloy in Ringer-Brown solution and artificial Carter-Brugirard saliva of different pH values was studied. In Ringer-Brown solution, the new alloy presented an improvement of all electrochemical parameters due to the alloying with Zr; also, impedance spectra revealed better protective properties of its passive layer. In Carter-Brugirard artificial saliva, an increase of the passive film thickness was proved. Fluoride ions had a slight negative influence on the corrosion and ion release rates, without to affect the very good stability of the new Ti-6Al-4V-1Zr alloy.

  3. Corrosion-Resistant High-Entropy Alloys: A Review

    Directory of Open Access Journals (Sweden)

    Yunzhu Shi

    2017-02-01

    Full Text Available Corrosion destroys more than three percent of the world’s gross domestic product. Therefore, the design of highly corrosion-resistant materials is urgently needed. By breaking the classical alloy-design philosophy, high-entropy alloys (HEAs possess unique microstructures, which are solid solutions with random arrangements of multiple elements. The particular locally-disordered chemical environment is expected to lead to unique corrosion-resistant properties. In this review, the studies of the corrosion-resistant HEAs during the last decade are summarized. The corrosion-resistant properties of HEAs in various aqueous environments and the corrosion behavior of HEA coatings are presented. The effects of environments, alloying elements, and processing methods on the corrosion resistance are analyzed in detail. Furthermore, the possible directions of future work regarding the corrosion behavior of HEAs are suggested.

  4. Corrosion behavior of corrosion resistant alloys in stimulation acids

    Energy Technology Data Exchange (ETDEWEB)

    Cheldi, Tiziana [ENI E and P Division, 20097 San Donato Milanese Milano (Italy); Piccolo, Eugenio Lo; Scoppio, Lucrezia [Centro Sviluppo Materiali, via Castel Romano 100, 00128 Rome (Italy)

    2004-07-01

    In the oil and gas industry, selection of CRAs for downhole tubulars is generally based on resistance to corrosive species in the production environment containing CO{sub 2}, H{sub 2}S, chloride and in some case elemental sulphur. However, there are non-production environments to which these materials must also be resistant for either short term or prolonged duration; these environments include stimulation acids, brine and completion fluids. This paper reports the main results of a laboratory study performed to evaluate the corrosion and stress corrosion behaviour to the acidizing treatments of the most used CRAs for production tubing and casing. Laboratory tests were performed to simulate both 'active' and 'spent' acids operative phases, selecting various environmental conditions. The selected steel pipes were a low alloyed steel, martensitic, super-martensitic, duplex 22 Cr, superduplex 25 Cr and super-austenitic stainless steels (25 Cr 35 Ni). Results obtained in the 'active' acid environments over the temperature range of 100-140 deg. C, showed that the blend acids with HCl at high concentration and HCl + HF represented too much severe conditions, where preventing high general corrosion and heavy localised corrosion by inhibition package becomes very difficult, especially for duplex steel pipe, where, in some case, the specimens were completely dissolved into the solution. On the contrary, all steels pipes were successfully protected by inhibitor when organic acid solution (HCOOH + CH{sub 3}COOH) were used. Furthermore, different effectiveness on corrosion protection was showed by the tested inhibitors packages: e.g. in the 90% HCl at 12% + 10 CH{sub 3}COOH acid blend. In 'spent' acid environments, all steel pipes showed to be less susceptible to the localised and general corrosion attack. Moreover, no Sulphide Stress Corrosion Cracking (SSC) was observed. Only one super-austenitic stainless steel U-bend specimen showed

  5. Enhanced Corrosion Resistance of Iron-Based Amorphous Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; Day, S D; Lian, T; Aprigliano, L F; Hailey, P D; Farmer, J C

    2007-02-18

    Iron-based amorphous alloys possess enhanced hardness and are highly resistant to corrosion, which make them desirable for wear applications in corrosive environments. It was of interest to examine the behavior of amorphous alloys during anodic polarization in concentrated salt solutions and in the salt-fog testing. Results from the testing of one amorphous material (SAM2X5) both in ribbon form and as an applied coating are reported here. Cyclic polarization tests were performed on SAM2X5 ribbon as well as on other nuclear engineering materials. SAM2X5 showed the highest resistance to localized corrosion in 5 M CaCl{sub 2} solution at 105 C. Salt fog tests of 316L SS and Alloy 22 coupons coated with amorphous SAM2X5 powder showed resistance to rusting. Partial devitrification may be responsible for isolated pinpoint rust spots in some coatings.

  6. Corrosion resistance of Fe-based amorphous alloys

    Energy Technology Data Exchange (ETDEWEB)

    Botta, W.J., E-mail: wjbotta@ufscar.br [LEPMI, UMR5279 CNRS, Grenoble INP, Université de Savoie, Université Joseph Fourier, 1130, Rue de la piscine, BP 75, 38402 Saint Martin d’Hères (France); Departamento de Engenharia de Materiais, Universidade Federal de São Carlos, Rod. Washington Luiz, Km 235, 13565-905 São Carlos, SP (Brazil); Berger, J.E.; Kiminami, C.S. [Departamento de Engenharia de Materiais, Universidade Federal de São Carlos, Rod. Washington Luiz, Km 235, 13565-905 São Carlos, SP (Brazil); Roche, V.; Nogueira, R.P. [LEPMI, UMR5279 CNRS, Grenoble INP, Université de Savoie, Université Joseph Fourier, 1130, Rue de la piscine, BP 75, 38402 Saint Martin d’Hères (France); Bolfarini, C. [Departamento de Engenharia de Materiais, Universidade Federal de São Carlos, Rod. Washington Luiz, Km 235, 13565-905 São Carlos, SP (Brazil)

    2014-02-15

    Highlights: ► We report corrosion properties of Fe-based amorphous alloys in different media. ► The Cr-containing alloys had corrosion resistance close to that of Pt in all media. ► The wide range of electrochemical stability is relevant in many industrial domains. -- Abstract: Fe-based amorphous alloys can be designed to present an attractive combination of properties with high corrosion resistance and high mechanical strength. Such properties are clearly adequate for their technological use as coatings, for example, in steel pipes. In this work, we studied the corrosion properties of amorphous ribbons of the following Fe-based compositions: Fe{sub 66}B{sub 30}Nb{sub 4}, [(Fe{sub 0.6}Co{sub 0.4}){sub 0.75}B{sub 0.2}Si{sub 0.05}]{sub 96}Nb{sub 4}, [(Fe{sub 0.7}Co{sub 0.3}){sub 0.75}B{sub 0.2}Si{sub 0.05}]{sub 96}Nb{sub 4}, Fe{sub 56}Cr{sub 23}Ni{sub 5.7}B{sub 16}, Fe{sub 53}Cr{sub 22}Ni{sub 5.6}B{sub 19} and Fe{sub 50}Cr{sub 22}Ni{sub 5.4}B{sub 23}. The ribbons were obtained by rapid solidification using the melt-spinning process, and were characterized by X-ray diffraction (XRD), differential scanning calorimetry (DSC) and optical (OM) and scanning electron microscopy (SEM). The corrosion properties were evaluated by corrosion potential survey and potentiodynamic polarization. The Cr containing alloys, that is the FeCrNiB type of alloys, showed the best corrosion resistance properties with the formation of a stable passive film that ensured a very large passivation plateau.

  7. Corrosion-resistant nickel-base alloys for gas turbines

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, J.W.; Hulsizer, W.R.

    1976-08-01

    Laboratory corrosion screening procedures used during the past ten years in developing nickel-base superalloys for gas turbine applications are described. Hot salt corrosion tests have included crucible and salt shower exposures. Reproducible techniques were established and alloy composition effects defined, leading to development of M313, IN-587, a IN-792. Correlations have been made with corrosion results in burner rigs, and engine experience confirming anticipated behavior is now becoming available. During this work a number of limitations of these accelerated laboratory tests were uncovered; these are discussed. Finally, brief descriptions of the states of development of alloy MA 755E (an oxide dispersion-strengthened superalloy) and IN-939 (a cast 23 percent chromium superalloy) are outlined as examples of advanced corrosion resistant, high strength materials of the future.

  8. Surface Corrosion Resistance in Turning of Titanium Alloy

    Directory of Open Access Journals (Sweden)

    Rui Zhang

    2015-01-01

    Full Text Available This work addresses the issues associated with implant surface modification. We propose a method to form the oxide film on implant surfaces by dry turning to generate heat and injecting oxygen-rich gas at the turning-tool flank. The morphology, roughness, composition, and thickness of the oxide films in an oxygen-rich atmosphere were characterized using scanning electron microscopy, optical profiling, and Auger electron spectroscopy. Electrochemical methods were used to study the corrosion resistance of the modified surfaces. The corrosion resistance trends, analyzed relative to the oxide film thickness, indicate that the oxide film thickness is the major factor affecting the corrosion resistance of titanium alloys in a simulated body fluid (SBF. Turning in an oxygen-rich atmosphere can form a thick oxide film on the implant surface. The thickness of surface oxide films processed at an oxygen concentration of 80% was improved to 4.6 times that of films processed at an oxygen concentration of 21%; the free corrosion potential shifted positively by 0.357 V, which significantly improved the corrosion resistance of titanium alloys in the SBF. Therefore, the proposed method may (partially replace the subsequent surface oxidation. This method is significant for biomedical development because it shortens the process flow, improves the efficiency, and lowers the cost.

  9. Environmental Cracking of Corrosion Resistant Alloys in the Chemical Process Industry - A Review

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B

    2006-12-04

    A large variety of corrosion resistant alloys are used regularly in the chemical process industry (CPI). The most common family of alloys include the iron (Fe)-based stainless steels, nickel (Ni) alloys and titanium (Ti) alloys. There also other corrosion resistant alloys but their family of alloys is not as large as for the three groups mentioned above. All ranges of corrosive environments can be found in the CPI, from caustic solutions to hot acidic environments, from highly reducing to highly oxidizing. Stainless steels are ubiquitous since numerous types of stainless steels exist, each type tailored for specific applications. In general, stainless steels suffer stress corrosion cracking (SCC) in hot chloride environments while high Ni alloys are practically immune to this type of attack. High nickel alloys are also resistant to caustic cracking. Ti alloys find application in highly oxidizing solutions. Solutions containing fluoride ions, especially acid, seem to be aggressive to almost all corrosion resistant alloys.

  10. Development of weldable, corrosion-resistant iron-aluminide alloys

    Energy Technology Data Exchange (ETDEWEB)

    Maziasz, P.J.; Goodwin, G.M.; Wang, X.L. [Oak Ridge National Laboratory, TN (United States)

    1995-05-01

    Corrosion-resistant, weldable FeAl alloys have been developed with improved high-temperature strength industrial applications. Previous processing difficulties with these alloys led to their evaluation as weld-overlay claddings on conventional structural steels to take advantage of their good properties now. Simplified and better processing methods for monolithic FeAl components are also currently being developed so that components for industrial testing can be made. Other avenues for producing FeAl coatings are currently being explored. Neutron scattering experiments residual stress distributions in the FeAl weld-overlay cladding began in FY 1993 and continued this year.

  11. The corrosion resistance of Nitinol alloy in simulated physiological solutions

    Energy Technology Data Exchange (ETDEWEB)

    Milosev, Ingrid, E-mail: ingrid.milosev@ijs.si [Jozef Stefan Institute, Department of Physical and Organic Chemistry, Jamova 39, SI-1000, Ljubljana (Slovenia); Valdoltra Orthopaedic Hospital, Jadranska c. 31, SI-6280 Ankaran (Slovenia); Kapun, Barbara [Jozef Stefan Institute, Department of Physical and Organic Chemistry, Jamova 39, SI-1000, Ljubljana (Slovenia)

    2012-07-01

    The corrosion behaviour of Nitinol alloy containing nearly equi-atomic composition of nickel and titanium and its constituent metals (nickel and titanium) was investigated in simulated Hanks physiological solution (pH value 7.5) and pH modified simulated Hanks physiological solution (pH values 4.5 and 6.5) and by electrochemical method of anodic potentiodynamic polarization at 37 Degree-Sign C. In this chloride-rich medium the corrosion stability of Nitinol is limited by the susceptibility to localized corrosion and is in that sense more similar to nickel than to titanium. The corrosion stability of Nitinol is strongly dependent on the surface preparation-grinding, polishing or chemical etching. Whereas a ground surface is not resistant to localized corrosion, polished and chemically etched surfaces are resistant to this type of corrosion attack. The reasons for this behaviour were investigated through metallurgical, topographical and chemical properties of the surface as a function of surface preparation. For that purpose, scanning electron microscopy combined with chemical analysis, confocal microscopy and X-ray photoelectron spectroscopy were used. The surface roughness decreased in the following order: chemically etched > ground > polished surface. Besides differences in topography, distinct differences in the chemical composition of the outermost surface are observed. Ground, rough surfaces comprised mainly titanium oxides and small amounts of nickel metal. Chemically etched and, especially, polished surfaces are composed of a mixture of titanium, nickel and titanium oxides, as studied by angle resolved X-ray photoelectron spectroscopy. These results emphasize the importance of detailed investigation of the metal surface since small differences in surface preparation may induce large differences in corrosion stability of material when exposed to corrosive environments. - Highlights: Black-Right-Pointing-Pointer The corrosion resistance of Nitinol is dependent

  12. Effect of Microstructure on the Performance of Corrosion Resistant Alloys

    OpenAIRE

    Kishan Roodbari, Marzieh

    2015-01-01

    Corrosion by pitting in aluminum alloys is a very complex process that can be affected by various factors such as chemical composition and microstructure of the alloys. The electrochemistry and distribution of second phases populating the alloy are the main factors that significantly influence the corrosion of aluminum alloys. The purpose of the present work is to contribute to a deeper understanding of how the chemical composition and microstructure affect the ability of an al...

  13. Improving Corrosion Resistance of Q235 Steel by Ni-Cr Alloyed Layer

    Institute of Scientific and Technical Information of China (English)

    HUANG Jun; ZHANG Pingze; WU Hongyan; BI Qiang

    2012-01-01

    Ni-Cr alloyed layer was formed on surface of Q235 steel by double glow plasma surface metallurgy to improve the corrosion resistance of substrate.The composition and microstructure of alloyed layer was analyzed by SEM and XRD.Potentiodynamic polarization and electrochemical impedance spectroscopy was applied to evaluate the corrosion resistance of the alloyed layer.The results showed working pressure had a great effect on structure of Ni-Cr alloyed layer,and the dense and smooth alloyed layer was prepared at 50 Pa working pressure.Compared with substrate,Ni-Cr alloyed layer exhibited higher corrosion potential,lower corrosion current density and larger charge transfer resistance,which indicated that Ni-Cr alloyed layer significantly modified the corrosion resistance of Q235 steel.

  14. A high-specific-strength and corrosion-resistant magnesium alloy

    Science.gov (United States)

    Xu, Wanqiang; Birbilis, Nick; Sha, Gang; Wang, Yu; Daniels, John E.; Xiao, Yang; Ferry, Michael

    2015-12-01

    Ultra-lightweight alloys with high strength, ductility and corrosion resistance are desirable for applications in the automotive, aerospace, defence, biomedical, sporting and electronic goods sectors. Ductility and corrosion resistance are generally inversely correlated with strength, making it difficult to optimize all three simultaneously. Here we design an ultralow density (1.4 g cm-3) Mg-Li-based alloy that is strong, ductile, and more corrosion resistant than Mg-based alloys reported so far. The alloy is Li-rich and a solute nanostructure within a body-centred cubic matrix is achieved by a series of extrusion, heat-treatment and rolling processes. Corrosion resistance from the environment is believed to occur by a uniform lithium carbonate film in which surface coverage is much greater than in traditional hexagonal close-packed Mg-based alloys, explaining the superior corrosion resistance of the alloy.

  15. Environmental Considerations in the Studies of Corrosion Resistant Alloys for High-Level Radioactive Waste Containment

    Energy Technology Data Exchange (ETDEWEB)

    Ilevbare, G O; Lian, T; Farmer, J C

    2001-11-26

    The corrosion resistance of Alloy 22 (UNS No.: N06022) was studied in simulated ground water of different pH values and ionic contents at various temperatures. Potentiodynamic polarization techniques were used to study the electrochemical behavior and measure the critical potentials in the various systems. Alloy 22 was found to be resistant to localized corrosion in the simulated ground waters tested.

  16. Influence of Trace Alloying Elements on Corrosive Resistance of Cast Stainless Steel

    Institute of Scientific and Technical Information of China (English)

    DUAN Han-qiao; YAN Xiang; WEI Bo-kang; LIN Han-tong

    2005-01-01

    The influences of trace alloying elements niobium, vanadium and zirconium on the corrosive resistance of 18-8 type cast stainless steel have been studied in deta() orthogonal design experiments. The results show that zirconium is mainly in the form of compound inclusions, which is unfavorable to promote the corrosive resistance of the cast stainless steel. It can alleviate the disadvantageous influence of carbon addition on corrosive resistance when some elements such as vanadium and niobium exist in the steel, and niobium has a remarkable influence on the intergranular corrosive resistance but unobvious on the pitting corrosion, and vanadium has a slightly favorable influence on the corrosive resistance of the steel.

  17. [Corrosion resistance and bond strength of dental alloys].

    Science.gov (United States)

    Schwickerath, H

    1990-07-01

    Investigated Ni-alloys, which showed extensive solubility of Ni particles in corrosion bathes due to DIN 13927, also revealed pronounced lost of bond strength to ceramic veneers when immersed into corrosion bathes of equal constitution. Noble metal alloys with a gold concentration more than 50 percent, however, showed no such large lost of bond strength. Pd alloys showed a lost of bond strength which increased with their Ga concentration. Co alloys revealed a behavior similar to the Ni alloys but with no obvious correlation between solubility and lost of bond strength.

  18. Effect of Heat Treatment on the Microstructure and Corrosion Resistance of Cu-Zn Alloy

    Institute of Scientific and Technical Information of China (English)

    Xu Tao; Zhang Hailong; Xiao Nianxin; Zhao Xiangling

    2007-01-01

    The microstructure of Cu-Zn alloy with different heat treatment conditions in 3.5% NaCl + NH3 solution were observed, and the average corrosion rates and electrochemical data of Cu-Zn alloy were measured, as well as the effect of heat treatment on microstructure and corrosion resistance of Cu-Zn alloy was analyzed. The results show that the microstructure of Cu-Zn alloy has been changed due to the heat treatment. As a results, the better corrosion resistance can be obtained for the Cu-Zn alloy quenched from 900℃ for 0.5h followed by tempered at 100℃ for 2h.

  19. Effect of High Temperature Aging on the Corrosion Resistance of Iron Based Amorphous Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Day, S D; Haslam, J J; Farmer, J C; Rebak, R B

    2007-08-10

    Iron-based amorphous alloys can be more resistant to corrosion than polycrystalline materials of similar compositions. However, when the amorphous alloys are exposed to high temperatures they may recrystallize (or devitrify) thus losing their resistance to corrosion. Four different types of amorphous alloys melt spun ribbon specimens were exposed to several temperatures for short periods of time. The resulting corrosion resistance was evaluated in seawater at 90 C and compared with the as-prepared ribbons. Results show that the amorphous alloys can be exposed to 600 C for 1-hr. without losing the corrosion resistance; however, when the ribbons were exposed at 800 C for 1-hr. their localized corrosion resistance decreased significantly.

  20. [Effect of aurum coating on corrosion resistance of Ni-Cr alloy].

    Science.gov (United States)

    Chen, Zhi-hong; Liu, Li; Mao, Ying-jie

    2007-02-01

    To evaluate the effect of aurum coating on corrosion resistance of Ni-Cr alloy in artificial saliva environment. The corrosion potential (E(corr)), self-corrosion current density (I(corr)), and polarization resistance (R(p)) of three alloys were measured using electrochemical methods to compare the difference of corrosion resistance between aurum-coated Ni-Cr alloy and Ni-Cr alloy or Au alloy. Meanwhile, microstructural and phase diffraction was examined with field scanning electromicroscopy (FSEM) and surface chemical analysis was performed by energy diffraction X-ray (EDX). The I(corr) of aurum-coated Ni-Cr alloy was (0.70 +/- 0.20) x 10(-6) A/cm2, which was significantly higher than that of Au alloy (P Cr alloy (P coated Ni-Cr alloy was (34.77 +/- 12.61) KOmega.cm2, which was higher than that of Ni-Cr alloy (P Cr alloy coated with aurum was better than that of Ni-Cr alloy. The results of EDX indicated that released Ni and Cr of Ni-Cr alloy coated with aurum after test were less than those of Ni-Cr alloy (P coated Ni-Cr alloy is higher than that of Ni-Cr alloy.

  1. Investigation of Corrosion Resistance Using Positron Annihilation for an Amorphous Alloy

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    An amorphous alloy with Ni-(17~19) at. pct P prepared by electrodeposition process was studied using positron annihilation technique (PAT) associated with X-ray diffraction and the measurement of corrosion rate. It is suggested that defect or the interface between precipitates and matrix is one of the important factors which decrease corrosion resistance of the alloy after crystallization.

  2. High Velocity Oxidation and Hot Corrosion Resistance of Some ODS Alloys

    Science.gov (United States)

    Lowell, C. E.; Deadmore, D. L.

    1977-01-01

    Several oxide dispersion strengthened (ODS) alloys were tested for cyclic, high velocity, oxidation, and hot corrosion resistance. These results were compared to the resistance of an advanced, NiCrAl coated superalloy. An ODS FeCrAl were identified as having sufficient oxidation and hot corrosion resistance to allow potential use in an aircraft gas turbine without coating.

  3. Corrosion resistance of amorphous and crystalline Pd40Ni40P20 alloys in aqueous solutions

    DEFF Research Database (Denmark)

    Wu, Y.F.; Chiang, Wen-Chi; Chu, J.

    2006-01-01

    The corrosion behaviors of amorphous and crystalline Pd40Ni40P20 alloys in various aqueous solutions are reported in this paper. The corrosion resistance of crystalline (annealed) Pd40Ni40P20 is better than that of amorphous Pd40Ni40P20 in various corrosive solutions, due to crystalline Pd40Ni40P20...

  4. Influence of inorganic acid pickling on the corrosion resistance of magnesium alloy AZ31 sheet

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Blawert, C.; Scharnagl, N.

    2009-01-01

    was investigated. Sulphuric, nitric and phosphoric acids of different concentrations were used to clean the alloy for various pickling times. The surface morphology, composition and phases were elucidated using scanning electron microscopy, X-ray fluorescence analysis, spark discharge-optical emission spectroscopy...... the corrosion resistance of the alloy. The cleaning efficiency of the three acids used and the corrosion protection mechanisms were found to be remarkably different. Best corrosion results were obtained with nitric acid, followed closely by phosphoric acid. Only the sulphuric acid failed more or less when...... of micro-galvanic couples and can therefore increase corrosion attack on these alloys. Due to this influence they should be removed to obtain good corrosion resistance. In this study, the effect of inorganic acid pickling on the corrosion behaviour of a commercial AZ31 magnesium alloy sheet...

  5. Enhancement of wear and corrosion resistance of beta titanium alloy by laser gas alloying with nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Chi-Wai, E-mail: c.w.chan@qub.ac.uk [School of Mechanical and Aerospace Engineering, Queen' s University Belfast, BT9 5AH (United Kingdom); Lee, Seunghwan [Department of Mechanical Engineering, Technical University of Denmark, DK-2800 Kgs. Lyngby (Denmark); Smith, Graham [Department of Natural Sciences, University of Chester, Thornton Science Park, Chester CH2 4NU (United Kingdom); Sarri, Gianluca [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Ng, Chi-Ho [School of Mechanical and Aerospace Engineering, Queen' s University Belfast, BT9 5AH (United Kingdom); Laser Engineering and Manufacturing Research Centre, Faculty of Science and Engineering, University of Chester, Parkgate Road, Chester CH1 4BJ (United Kingdom); Sharba, Ahmed [School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Man, Hau-Chung [Department of Industrial and Systems Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong (China)

    2016-03-30

    Graphical abstract: - Highlights: • Laser technology is a fast, clean and flexible method for surface hardening of TNZT. • Laser can form a protective hard layer on TNZT surface without altering surface roughness. • The laser-formed layer is metallurgically bonded to the substrate. • Laser-treated TNZT is highly resistant to corrosion and wear in Hank's solution. - Abstract: The relatively high elastic modulus coupled with the presence of toxic vanadium (V) in Ti6Al4V alloy has long been a concern in orthopaedic applications. To solve the problem, a variety of non-toxic and low modulus beta-titanium (beta-Ti) alloys have been developed. Among the beta-Ti alloy family, the quaternary Ti–Nb–Zr–Ta (TNZT) alloys have received the highest attention as a promising replacement for Ti6Al4V due to their lower elastic modulus and outstanding long term stability against corrosion in biological environments. However, the inferior wear resistance of TNZT is still a problem that must be resolved before commercialising in the orthopaedic market. In this work, a newly developed laser surface treatment technique was employed to improve the surface properties of Ti–35.3Nb–7.3Zr–5.7Ta alloy. The surface structure and composition of the laser-treated TNZT surface were examined by grazing incidence X-ray diffraction (GI-XRD) and X-ray photoelectron spectroscopy (XPS). The wear and corrosion resistance were evaluated by pin-on-plate sliding test and anodic polarisation test in Hanks’ solution. The experimental results were compared with the untreated (or base) TNZT material. The research findings showed that the laser surface treatment technique reported in this work can effectively improve the wear and corrosion resistance of TNZT.

  6. Corrosion resistance of 15Mo3 in steam boiler pipe surfaced with Inconel 625 alloy

    Energy Technology Data Exchange (ETDEWEB)

    Aracic, S.; Samardzic, I.; Krumes, D. [Mechanical Engineering Faculty, Trg Ivane Brlic Mazuranic 18, HR-35000 Slavonski Brod (Croatia)

    2004-07-01

    This paper presents accelerated laboratory corrosion resistant investigation results made on steam boiler 15Mo3 steel pipes surfaced with alloy Inconel 625. Surfacing of 15Mo3 pipes was made due to pipes corrosion resistance increase in exploitation conditions which are present in fire box of trash burning plant. Corrosion resistance investigations were made in fire box simulated atmosphere and in salt spray chamber. (authors)

  7. Mechanical properties and corrosion resistance of some titanium alloys in marine environment

    Directory of Open Access Journals (Sweden)

    Dupuis Jennifer

    2013-11-01

    Full Text Available Titanium alloys are used in several fields such as aerospace industry or biomedical. They are increasingly used in marine applications, a highly corrosive environment. We chose titanium alloys for their good properties such as high mechanical strength, low density and excellent corrosion resistance. This study is focused on titanium alloys potentially interesting to be used in marine transports, and mainly for the boats fittings such as a winch for example.

  8. Enhancement of wear and corrosion resistance of beta titanium alloy by laser gas alloying with nitrogen

    DEFF Research Database (Denmark)

    Chan, Chi-Wai; Lee, Seunghwan; Smith, Graham

    2016-01-01

    , the quaternary Ti-Nb-Zr-Ta (TNZT) alloys have received the highest attention as a promising replacement for Ti6Al4V due to their lower elastic modulus and outstanding long term stability against corrosion in biological environments. However, the inferior wear resistance of TNZT is still a problem that must...... be resolved before commercialising in the orthopaedic market. In this work, a newly developed laser surface treatment technique was employed to improve the surface properties of Ti-35.3Nb-7.3Zr-5.7Ta alloy. The surface structure and composition of the laser-treated TNZT surface were examined by grazing...... findings showed that the laser surface treatment technique reported in this work can effectively improve the wear and corrosion resistance of TNZT....

  9. Microstructure and corrosion resistance of AlCrFeCuCo high entropy alloy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, Xing-Wu, E-mail: qiuxingwu@126.com [School of Material Science and Engineering, Xi' an University of Technology, Xi' an 710048 (China); Department of Materials Engineering, Sichuan College of Architectural Technology, Deyang 618000 (China); Zhang, Yun-Peng; He, Li [School of Material Science and Engineering, Xi' an University of Technology, Xi' an 710048 (China); Liu, Chun-ge [Department of Transportation and Municipal Engineering, Sichuan College of Architectural Technology, Deyang 618000 (China)

    2013-02-05

    Highlights: Black-Right-Pointing-Pointer We use a new method (laser cladding) to prepare high-entropy alloy. Black-Right-Pointing-Pointer We gained small microstructure under rapid solidification condition. Black-Right-Pointing-Pointer We studied corrosion resistance of AlCrFeCuCo high-entropy alloy in two different liquids. - Abstract: The AlCrFeCuCo high-entropy alloys were prepared by the laser cladding method. The microstructure and corrosion resistance property of AlCrFeCuCo high-entropy alloy were researched by scanning electron microscopy, X-ray diffraction and electrochemical workstation. The results show that, under the rapid solidification small microstructure gained, the morphology of AlCrFeCuCo high entropy alloy is simple, the phase mainly compose of FCC and BCC; elements segregated in the alloys; the alloy shows excellent corrosion resistance, along with the increase of the scanning speed, alloy corrosion resistance performance shows a enhancement in the first and then weakened trend. The corrosion resistance performance of AlCrFeCuCo high-entropy alloys in 1 mol/L NaCl solution is better than in 0.5 mol/L H{sub 2}SO{sub 4} solution.

  10. Improving Corrosion Resistance of Ferrous Alloy to Molten Zn by Modifying the Laves Phase Characteristics

    Science.gov (United States)

    Liu, X.; Yin, F. C.; Lou, J.; Ouyang, X. M.; Li, Z.

    2017-08-01

    The Laves phase morphology in the Fe25Mo14Cr10Ni1Si (wt.%) alloy was modified by Si addition to improve the corrosion resistance of the ferrous alloy to molten zinc. The Si-containing alloy showed a woven, needle-like Laves phase with higher Mo content than that of the Fe25Mo14Cr10Ni alloy. Corrosion resistance to molten Zn for the Si-containing alloy was more than 20 times higher than that of the silicon-free alloy mainly as a result of the characteristics of the modified Laves phase. This phase was oriented perpendicular to the Zn-diffusion direction, which effectively prevented corrosion by the molten Zn, leading to a denser FeZn13 layer rather than the FeZn10 layer produced in the Fe25Mo14Cr10Ni alloy.

  11. The Influence of Transition Metals Addition on the Corrosion Resistance of Nanocrystalline Al Alloys Produced by Mechanical Alloying

    Directory of Open Access Journals (Sweden)

    Asiful Hossain Seikh

    2016-06-01

    Full Text Available The corrosion resistance of nanocrystalline Al, Al-10 wt. % Fe and Al-10 wt. % Fe-5 wt. % Cr alloys was investigated in 3.5% NaCl solution using cyclic potentiodynamic polarization (CPP and electrochemical impedance spectroscopy (EIS techniques. The alloys were fabricated using mechanical alloying (MA and heat induction sintering. When compared with the corrosion resistance of pure Al, the experimental results indicated that the addition of 10 wt. % Fe and 10 wt. % Fe-5 wt. % Cr to pure Al has resulted in an enhancement in the corrosion resistance of these newly fabricated alloys. The resistance to corrosion is due to enhanced microstructural stability along with the formation of stable oxide layer.

  12. Improvement of corrosion resistance of AZ91D magnesium alloy by gadolinium addition

    Institute of Scientific and Technical Information of China (English)

    ZHOU Xue-hua; WEI Zhong-ling; CHEN Qiu-rong; GAN Fu-xing

    2006-01-01

    Based on the previous investigation on beneficial introduction of holmium into magnesium alloy, the effect of gadolinium, an adjacent rare earth element, on corrosion resistance was examined. The corrosion behavior of two Mg-9Al-Gd alloys (Mg-9Al-0.45Gd and Mg-9Al-1.43Gd) was evaluated and compared with that of Mg-9Al alloy without Gd by means of specimen mass loss and hydrogen evolution in 3.5% NaCl solution saturated with Mg(OH)2. The Gd-containing alloys exhibit enhanced corrosion resistance with respect to the plain Mg-9Al alloy. The microstructures of Mg-9Al alloy and Mg-9Al-0.45 Gd alloy were observed by electron probe microanalysis (EPMA) and energy dispersion spectroscopy (EDS). The alloys with Gd addition show a microstructure characterized by α phase solid solution, surrounded by minor amount of β phase and more grain-like Gd-containing phase. To illustrate the involved mechanism their polarization curves were recorded. The electrochemical investigations reveal that Gd addition shifts the corrosion potential of the alloy towards active, as Gd containing phase is more active and hence less cathodic. As a result, the micro-galvanic corrosion is suppressed. Moreover corrosion product films formed on the Gd containing alloys are more compact and provide a better protective effectiveness than that on the alloy without Gd against corrosion. Repassivation measurements in mixture solution of 0.21 mol/L K2CrO4+0.6 mol/L NaCl also verify the beneficial role of Gd addition. Based on the present preliminary analysis, both the deposited Gd-containing phases and corrosion product films are believed to be responsible for the improved corrosion behaviour due to Gd addition.

  13. Increased corrosion resistance of the AZ80 magnesium alloy by rapid solidification.

    Science.gov (United States)

    Aghion, E; Jan, L; Meshi, L; Goldman, J

    2015-11-01

    Magnesium (Mg) and Mg-alloys are being considered as implantable biometals. Despite their excellent biocompatibility and good mechanical properties, their rapid corrosion is a major impediment precluding their widespread acceptance as implantable biomaterials. Here, we investigate the potential for rapid solidification to increase the corrosion resistance of Mg alloys. To this end, the effect of rapid solidification on the environmental and stress corrosion behavior of the AZ80 Mg alloy vs. its conventionally cast counterpart was evaluated in simulated physiological electrolytes. The microstructural characteristics were examined by optical microscopy, SEM, TEM, and X-ray diffraction analysis. The corrosion behavior was evaluated by immersion, salt spraying, and potentiodynamic polarization. Stress corrosion resistance was assessed by Slow Strain Rate Testing. The results indicate that the corrosion resistance of rapidly solidified ribbons is significantly improved relative to the conventional cast alloy due to the increased Al content dissolved in the α-Mg matrix and the correspondingly reduced presence of the β-phase (Mg17 Al12 ). Unfortunately, extrusion consolidated solidified ribbons exhibited a substantial reduction in the environmental performance and stress corrosion resistance. This was mainly attributed to the detrimental effect of the extrusion process, which enriched the iron impurities and increased the internal stresses by imposing a higher dislocation density. In terms of immersion tests, the average corrosion rate of the rapidly solidified ribbons was <0.4 mm/year compared with ∼2 mm/year for the conventionally cast alloy and 26 mm/year for the rapidly solidified extruded ribbons.

  14. Wear resistance and hot corrosion behaviour of laser cladding Co-based alloy

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    2Cr13 stainless steel was surface cladded with Co-based alloy using a high power carbon dioxide laser. The microstructure, wear resistance and corrosion properties of the clad layer were investigated. It is found that the high temperature corrosion behavior and wearing resistant property of the clad layer are 3 and 2.5 times higher than those of the parent metal. Under the high temperature molten lead sulphate salt corrosion condition, the clad layer fails by spalling which is caused by intergrannular corrosion within the clad layer. The fine dendritic structure and the oxide help to retard the penetration of the sulphur ion that induces the intergrannular corrosion.

  15. Effect of rare earths on corrosion resistance of Cu-30Ni alloys in simulated seawater

    Institute of Scientific and Technical Information of China (English)

    毛向阳; 方峰; 蒋建清; 谈荣生

    2009-01-01

    Cu-30Ni-xRE(x=0-0.213 wt.%) alloy was prepared by adding rare earths(RE) in melted Cu-30Ni alloy using metal mould casting method.The effects of RE on corrosion resistance of the alloy in simulated seawater were investigated using optical microscope,scanning electronic microscope with energy-dispersive spectrometer and electrochemical measurement system.The results showed that the corrosion resistance of Cu-30Ni alloy was greatly improved by adding proper amount of RE,whereas excess addition of RE worsened ...

  16. Structure and Corrosion Resistance of Microarc Oxidation Coatings on AZ91D Magnesium Alloy

    Institute of Scientific and Technical Information of China (English)

    Cui Shihai; Han Jianmin; Li Weijing; Li Ronghua; Zhu Xiaowen; Wang Jinhua

    2004-01-01

    Magnesium alloys are widely used as shells of 3C (computer, mobile phone and consumer electronics) equipments for its impressive mechanical and physical properties, such as low density, good resistance to electromagnetic radiation, suitable for high pressure diecasting and easily recycling, etc. But poor corrosion resistance confines its extensively application. In this paper, protective coatings was successfully prepared on AZ91D magnesium alloys by micro-arc oxidation (MAO) and painting process. Microstructures and phases of MAO coatings were invesgated with scanning electron microscope (SEM) and X-Ray diffractometer. Mechanical properties of MAO coating, such as adhesive force and corrosion resistance, were also tested. Results showed that MAO coatings were a good base for painting process. MAO coatings with paint have good adhesive properties to base metal and excellent corrosion resistance. Micro-arc oxidation with painting process is a good kind of surface treatment to improve the corrosion resistance of mobile phone shell made of AZ91D magnesium alloys.

  17. Electrodeposition of high corrosion resistance Cu/Ni-P coating on AZ91D magnesium alloy

    Science.gov (United States)

    Zhang, Shan; Cao, Fahe; Chang, Linrong; Zheng, JunJun; Zhang, Zhao; Zhang, Jianqing; Cao, Chunan

    2011-08-01

    High corrosion resistance Cu/Ni-P coatings were electrodeposited on AZ91D magnesium alloy via suitable pretreatments, such as one-step acid pickling-activation, once zinc immersion and environment-friendly electroplated copper as the protective under-layer, which made Ni-P deposit on AZ91D Mg alloy in acid plating baths successfully. The pH value and current density for Ni-P electrodeposition were optimized to obtain high corrosion resistance. With increasing the phosphorous content of the Ni-P coatings, the deposits were found to gradually transform to amorphous structure and the corrosion resistance increased synchronously. The anticorrosion ability of AZ91D Mg alloy was greatly improved by the amorphous Ni-P deposits, which was investigated by potentiodynamic polarization curve and electrochemical impedance spectroscopy (EIS). The corrosion current density ( Icorr) of the coated Mg alloy substrate is about two orders of magnitude less than that of the uncoated.

  18. Recent developments in wear- and corrosion-resistant alloys for the oil industry

    Energy Technology Data Exchange (ETDEWEB)

    Raghu, D. [Deloro Stellite Inc., Goshen, IN (United States). Stellite Coatings Div.; Wu, J.B.C. [Stoody Deloro Stellite, Inc., St. Louis, MO (United States)

    1997-11-01

    Oil production and refining pose very severe wear and corrosion environments. Material designers are challenged with the need to design and develop materials that combine high corrosion resistance with good wear resistance. Coupled with that is the need for these materials to meet requirements such as fracture toughness and resistance to sulfide and chloride stress corrosion cracking. Often, increasing wear resistance compromises the corrosion and welding characteristics. This article covers a variety of material developments that address the problems of wear and corrosion, including alloy design fundamentals and pertinent wear properties and general corrosion resistance compared to traditional wear-resistant materials. Proven applications, with particular reference to petroleum and petrochemical areas, are discussed. Potential applications are also cited.

  19. Heat treatment of NiCrFe alloy 600 to optimize resistance to intergranular stress corrosion

    Science.gov (United States)

    Steeves, A.F.; Bibb, A.E.

    A process of producing a NiCrFe alloy having a high resistance to stress corrosion cracking comprises heating a NiCrFe alloy to a temperature sufficient to enable the carbon present in the alloy body in the form of carbide deposits to enter into solution, rapidly cooling the alloy body, and heating the cooled body to a temperature between 1100 to 1500/sup 0/F for about 1 to 30 hours.

  20. Corrosion resistance and electrochemical potentiokinetic reactivation testing of some iron-base hardfacing alloys

    Energy Technology Data Exchange (ETDEWEB)

    Cockeram, B.V.

    1999-11-01

    Hardfacing alloys are weld deposited on a base material to provide a wear resistant surface. Commercially available iron-base hardfacing alloys are being evaluated for replacement of cobalt-base alloys to reduce nuclear plant activation levels. Corrosion testing was used to evaluate the corrosion resistance of several iron-base hardfacing alloys in highly oxygenated environments. The corrosion test results indicate that iron-base hardfacing alloys in the as-deposited condition have acceptable corrosion resistance when the chromium to carbon ratio is greater than 4. Tristelle 5183, with a high niobium (stabilizer) content, did not follow this trend due to precipitation of niobium-rich carbides instead of chromium-rich carbides. This result indicates that iron-base hardfacing alloys containing high stabilizer contents may possess good corrosion resistance with Cr:C < 4. NOREM 02, NOREM 01, and NoCo-M2 hardfacing alloys had acceptable corrosion resistance in the as-deposited and 885 C/4 hour heat treated condition, but rusting from sensitization was observed in the 621 C/6 hour heat treated condition. The feasibility of using an Electrochemical Potentiokinetic Reactivation (EPR) test method, such as used for stainless steel, to detect sensitization in iron-base hardfacing alloys was evaluated. A single loop-EPR method was found to provide a more consistent measurement of sensitization than a double loop-EPR method. The high carbon content that is needed for a wear resistant hardfacing alloy produces a high volume fraction of chromium-rich carbides that are attacked during EPR testing. This results in inherently lower sensitivity for detection of a sensitized iron-base hardfacing alloy than stainless steel using conventional EPR test methods.

  1. Advanced Corrosion-Resistant Zr Alloys for High Burnup and Generation IV Applications

    Energy Technology Data Exchange (ETDEWEB)

    Arthur Motta; Yong Hwan Jeong; R.J. Comstock; G.S. Was; Y.S. Kim

    2006-10-31

    The objective of this collaboration between four institutions in the US and Korea is to demonstrate a technical basis for the improvement of the corrosion resistance of zirconium-based alloys in more extreme operating environments (such as those present in severe fuel duty,cycles (high burnup, boiling, aggressive chemistry) andto investigate the feasibility (from the point of view of corrosion rate) of using advanced zirconium-based alloys in a supercritical water environment.

  2. The corrosion resistance and neutron-absorbing properties of coatings based on amorphous alloys

    Science.gov (United States)

    Sevryukov, O. N.; Polyansky, A. A.

    2016-04-01

    The object of the present study was the corrosion-resistant amorphizing alloys with an increased content of boron for cladding the surface of metals, rapidly quenched alloys without boron for protective coatings on a high-boron cladding layer, as well as steel samples with a protective coating with a high content of boron and without boron. The aim of the work is to investigate the corrosion resistance of a coating in water at the temperature of 40 °C in conditions of an open access of oxygen for 1000 h, as well as the features of the microstructure of clad samples before and after the corrosion tests. New data on the corrosion resistance of Cr18Ni10Ti steel samples with a protective layer from a rapidly quenched alloy Ni-19Cr-10Si (in wt.%) on a high-boron coating have been obtained.

  3. Corrosion resistance of amorphous and crystalline Pd40Ni40P20 alloys in aqueous solutions

    DEFF Research Database (Denmark)

    Wu, Y.F.; Chiang, Wen-Chi; Chu, J.;

    2006-01-01

    The corrosion behaviors of amorphous and crystalline Pd40Ni40P20 alloys in various aqueous solutions are reported in this paper. The corrosion resistance of crystalline (annealed) Pd40Ni40P20 is better than that of amorphous Pd40Ni40P20 in various corrosive solutions, due to crystalline Pd40Ni40P20...... and mainly consists of inert Pd5P2, NI3P, Ni2Pd2P and noble Pd phases. These inert and noble properties result in a higher corrosion resistance in crystalline Pd40Ni40P20....

  4. Preparation and Corrosion Resistance of Rare Earth Conversion Coatings on AZ91 Magnesium Alloy

    Institute of Scientific and Technical Information of China (English)

    Xu Yue; Chen Xiang; Lü Zushun; Li Yingjie

    2005-01-01

    The feasibility of forming pollution-free and environmentally benign Ce-based rare earth conversion coatings (short for RECCs) on AZ91 magnesium alloy to enhance corrosion resistance was studied. The effect of optimum processing parameters on corrosion resistance of RECCs, such as density of treating solution, temperature and time of coating formation were discussed. Protective performance of conversion coatings on magnesium alloy was evaluated by moisture/heating test, anodic polarization, etc. The results show that Ce-based RECCs under moisture/heating condition can remain intact, with high coverage and no obvious corrosion phenomenon. Corrosion potential increases and passive phenomenon occurs while current density decreases, therefore Ce-based RECCs can improve corrosion resistance of AZ91 magnesium alloy. The morphology of Ce-based RECCs prepared under optimum process through SEM observation is found to be a few particles coherent to the base coating, and the coating has no cracks and exhibits apparent corrosion resistance during corrosion courses of AZ91 magnesium alloy.

  5. Corrosion resistance, composition and structure of RE chemical conversion coating on magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Golden yellow rare earths chemical conversion coating was obtained on the surface of magnesium alloy by immersing in cerium sulfate solution.The corrosion resistance of RE conversion coating was evaluated using immersion test and potentiodynamic polarization measurements in 3.5%NaCl solution.The morphologies of samples before corrosion and after corrosion were observed by SEM.The structures and compositions of the RE conversion coating were studied by means of XPS.XRD and IR.The results show that,the conversion coating consists of mainly two kinds of element Ce and O,the valences of cerium are+3 and+4.and OH exists in the coating.The anti-corrosion property of magnesium alloy is increased obviously by rare earths conversion coating,Its self-corrosion current density decreases and the coating has self-repairing capability in the corrosion process in 3.5%NaCl solution.

  6. Studies on Wear and Corrosion Resistances of Carbon Nitride Thin Films on Ti Alloy

    Institute of Scientific and Technical Information of China (English)

    LiJin-chai; GuoHuai-xi; LuXlan-feng; ZhangZhi-hong; YeMing-sheng

    2003-01-01

    CNx/SiCN composite films were prepared on titanium ( Ti ) alloy substrates by Radio Frequency Plasma Enhanced Chemical Vapor Deposition ( RF-PECVD ). As a buffer layer, SiCN ensured the adhesion of the CNx thin films on Ti substrates. X-ray diffraction (XRD) measurement revealed that the composite films possessed α-C3N4 structure.The microhardness of the films was 48 to 50 GPa. In or der totest the characteristics of wear and corrosion resistances, we prepared Ti alloy samples with and without CNx/SiCN composite films. Also for strengthening the effect of wear and corrosion, the wear tests were carried out under high load (12 MPa) and in 0. 9% NaCl solution. Results of the wear tests and the corrosive electrochemical measurements showed that the samples coated with CNx films had excellent charac-teristics of wear and corrosion resistances compared with Ti alloy substrate samples.

  7. Studies on Wear and Corrosion Resistances of Carbon Nitride Thin Films on Ti Alloy

    Institute of Scientific and Technical Information of China (English)

    Li Jin-chai; Guo Huai-xi; Lu Xian-feng; Zhang Zhi-hong; Ye Ming-sheng

    2003-01-01

    CNx/SiCN composite films were prepared on titanium ( Ti ) alloy substrates by Radio Frequency Plasma Enhanced Chemical Vapor Deposition ( RF-PECVD ). As a buffer layer, SiCN ensured the adhesion of the CNx thin films on Ti substrates. X-ray diffraction (XRD) measurement revealed that the composite films possessed α-C3N4 structure.The microhardness of the films was 48 to 50 GPa. In order to test the characteristics of wear and corrosion resistances, we prepared Ti alloy samples with and without CNx/SiCN composite films. Also for strengthening the effect of wear and corrosion, the wear tests were carried out under high load (12 MPa) and in 0. 9% NaCl solution. Results of the wear tests and the corrosive electrochemical measurements showed that the samples coated with CNx films had excellent characteristics of wear and corrosion resistances compared with Ti alloy substrate samples.

  8. Optimization of friction stir welding parameters for improved corrosion resistance of AA2219 aluminum alloy joints

    Directory of Open Access Journals (Sweden)

    G. Rambabu

    2015-12-01

    Full Text Available The aluminium alloy AA2219 (Al–Cu–Mg alloy is widely used in the fabrication of lightweight structures with high strength-to-weight ratio and good corrosion resistance. Welding is main fabrication method of AA2219 alloy for manufacturing various engineering components. Friction stir welding (FSW is a recently developed solid state welding process to overcome the problems encountered in fusion welding. This process uses a non-consumable tool to generate frictional heat on the abutting surfaces. The welding parameters, such as tool pin profile, rotational speed, welding speed and axial force, play major role in determining the microstructure and corrosion resistance of welded joint. The main objective of this work is to develop a mathematical model to predict the corrosion resistance of friction stir welded AA2219 aluminium alloy by incorporating FSW process parameters. In this work a central composite design with four factors and five levels has been used to minimize the experimental conditions. Dynamic polarization testing was carried out to determine critical pitting potential in millivolt, which is a criteria for measuring corrosion resistance and the data was used in model. Further the response surface method (RSM was used to develop the model. The developed mathematical model was optimized using the simulated annealing algorithm optimizing technique to maximize the corrosion resistance of the friction stir welded AA2219 aluminium alloy joints.

  9. Preparation and corrosion resistance of MAO/Ni-P composite coat on Mg alloy

    Science.gov (United States)

    Fan, Xizhi; Wang, Ying; Zou, Binglin; Gu, Lijian; Huang, Wenzhi; Cao, Xueqiang

    2013-07-01

    Microarc oxidation (MAO) coat was designed as an intermediate layer for the electroless plated Ni-P top coat, providing inert surface and necessary hardness for Mg alloy substrate. The composite coat was successfully prepared to improve the corrosion resistance of Mg alloy. The preparation and the characterization of the composite coat were investigated. The results show that the pre-treatment of MAO before electroless plating plays an important role in the deposition of compact composite coat. The activation (by HF solution) makes the MAO coat dense with uniform cracks which supply excellent bonding interface for Ni-P coat. Compared with monolithic MAO or Ni-P coat, the composite coat has excellent corrosion resistance and stable bonding interface. There is main pit corrosion at substrate after the corrosive medium penetrating through the whole coat. With the inert MAO interlayer, the electrochemical corrosion between the Ni-P and substrate is effectively inhibited.

  10. Effects of organic acid pickling on the corrosion resistance of magnesium alloy AZ31 sheet

    DEFF Research Database (Denmark)

    Nwaogu, Ugochukwu Chibuzoh; Blawert, C.; Scharnagl, N.;

    2010-01-01

    mu m of the contaminated surface was required to reach corrosion rates less than 1 mm/year in salt spray condition. Among the three organic acids examined, acetic acid is the best choice. Oxalic acid can be an alternative while citric acid is not suitable for cleaning AZ31 sheet, because......Organic acids were used to clean AZ31 magnesium alloy sheet and the effect of the cleaning processes on the surface condition and corrosion performance of the alloy was investigated. Organic acid cleanings reduced the surface impurities and enhanced the corrosion resistance. Removal of at least 4...

  11. The Nature of Surface Oxides on Corrosion-Resistant Nickel Alloy Covered by Alkaline Water

    Directory of Open Access Journals (Sweden)

    Gervasio DF

    2010-01-01

    Full Text Available Abstract A nickel alloy with high chrome and molybdenum content was found to form a highly resistive and passive oxide layer. The donor density and mobility of ions in the oxide layer has been determined as a function of the electrical potential when alkaline water layers are on the alloy surface in order to account for the relative inertness of the nickel alloy in corrosive environments.

  12. Effect of coating and surface modification on the corrosion resistance of selected alloys in supercritical water

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.; Zheng, W. [CANMET, Materials Technology Lab., Hamilton, Ontario (Canada); Cook, W. [Univ. of New Brunswick, Fredericton, New Brunswick (Canada); Toivonen, A.; Penttila, S. [VTT Technical Research Center of Finland, Espoo (Finland); Guzonas, D.; Woo, O.T. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Liu, P.; Bibby, D. [CANMET, Materials Technology Lab., Hamilton, Ontario (Canada)

    2011-07-01

    Materials selection is one of the key tasks in Gen-IV reactor development. There is no known material that can meet the expected core outlet conditions of the Canadian SCWR concept (625{sup o}C core outlet temperature). High-Cr steels with excellent corrosion resistance are often susceptible to embrittlement due to the precipitation of sigma and other phases in the microstructure. Low-Cr steels such as P91 and oxide dispersion strengthened (ODS) steels exhibit good high-temperature mechanical properties, but the lack of sufficient Cr content makes this group alloy corrode too fast. Improvement in this alloy is needed in order for it to be considered as a piping construction material. In this report, the development of a metallic coating on a P91 substrate is discussed. Recent effort on selection of in-core cladding alloys has focused on heat-resistant 3xx series stainless steels. These alloys have higher strength at high-temperature ranges, but corrosion and stress-corrosion cracking resistance are a concern. Metallic coating and surface modification are considered as possible solutions to overcome this challenge. The effects of surface modification on the corrosion rate of austenitic steels were also reported in this paper. As-machined surface showed much better corrosion resistance than polished surface and advanced surface analyses showed distinct differences in the nature and the morphology of the surface layer metal. Possible mechanisms for improved corrosion performance are discussed. (author)

  13. Phase constitution and corrosion resistance of Al–Co alloys

    Energy Technology Data Exchange (ETDEWEB)

    Palcut, Marián, E-mail: marian.palcut@gmail.com; Priputen, Pavol; Šalgó, Kristián; Janovec, Jozef

    2015-09-15

    Al–24Co, Al–25Co, Al–26Co, Al–27Co and Al–28Co alloys (composition in atomic percent) were prepared by arc-melting in high purity argon. Each alloy was found to consist of several microstructure constituents. Precipitation sequences of different intermetallic compounds were described based on a previously published Al–Co phase diagram and non-equilibrium processes taking place during casting. Electrochemical corrosion was investigated by potentiodynamic polarization in aqueous NaCl solution at room temperature. A large amount of pitting is observed, with some of the phases being preferentially corroded. The nobility of Al–Co intermetallic compounds is discussed in terms of chemical composition and crystal structure. Conclusions towards the alloy stability are provided. - Highlights: • Al–24Co to Al–28Co alloys were prepared by arc-melting in high purity argon. • Precipitation sequences of different intermetallic compounds have been observed. • Anodic alloy dissolution takes place by galvanic mechanism. • Nobility of Al–Co intermetallic compounds increases with increasing Co concentration.

  14. Influence of casting procedures on the corrosion resistance of clinical dental alloys containing palladium.

    Science.gov (United States)

    Viennot, Stéphane; Lissac, Michèle; Malquarti, Guillaume; Dalard, Francis; Grosgogeat, Brigitte

    2006-05-01

    The aim of this study was to compare the in vitro corrosion resistance in artificial saliva of two palladium-silver alloys (a Pd-Ag (Pors on 4) and an Ag-Pd (Palliag LTG)), with and without casting defects; 1 nickel-chrome alloy and 1 high-gold alloy, cast under recommended conditions, served as controls. For each of the palladium-based alloys, three specimens corresponding to three different casting conditions were used: under recommended conditions, with the use of a graphite-containing investment and crucible, and by reusing the sprues and sprue button. The electrochemical tests were run in Fusayama-Meyer artificial saliva. The open-circuit potential was recorded in mV/SCE at t=24h. Then, potentiodynamic polarization was performed to measure the polarization resistance (R(p)) in kOmega cm(2) and the corrosion current (i(corr)) in microA cm(-2). Data were evaluated with one-way analysis of variance and multiple comparisons test (alpha=0.05). In addition, each specimen was examined by scanning electron microscopy. Compared to the control alloys, the electrochemical experiments in artificial saliva indicated satisfactory corrosion resistance for the Pd-Ag and Ag-Pd alloys; these results are related to their high noble metal content and stable substructure. The Pd-Ag alloy displayed superior electrochemical properties to those of the Ag-Pd alloy regardless of the casting condition. The use of the graphite-containing crucible and investment during the cast process did not dramatically reduce the corrosion resistance values, but the reuse of sprues and the sprue button did. The optimal corrosion resistance values were obtained for the alloys cast according to the recommended conditions.

  15. Corrosion resistance of benzotriazole passivated Cu-Zn-Al shape memory alloy in artificial Ringer's solution

    Institute of Scientific and Technical Information of China (English)

    LIANG Chenghao; CHEN Bangyi; CHEN Wan; WANG Hua

    2005-01-01

    The corrosion resistance of the Cu-Zn-Al shape memory alloy passivated by benzotriazole was investigated by salt spraying test and electrochemical methods in artificial Ringer's solution. The results showed that after benzotriazole passivation, the corrosion resistance of the Cu-Zn-Al shape memory alloy was improved evidently. The anodic polarization current density of the passivated alloy decreased, the mass loss reduced, the anodic passivation accelerated, the anodic active dissolution was inhibited effectively, and the surface tarnishing was restrained. Infrared reflection spectrum test showed that Cu(Ⅰ)-benzoaiazole or Cu(Ⅱ)-benzotriazole complex layer was formed on the surface of the Cu-Zn-Al shape memory alloy after passivation. This layer appeared plane, well adhesion, and presented homogeneous golden metallic luster. The corrosion resistance of the Cu-Zn-Al shape memory alloy passivated by benzotriazole is improved for the formation of an electrochemical stable baffle layer on passivated surface. This layer separates the metal substrate from the outside corrosion medium effectively and retards the corrosion process of dezincification.

  16. Correlation Between Microstructure and Corrosion Resistance of Magnesium Alloys Prepared by High Strain Rate Rolling

    Science.gov (United States)

    Chen, Jihua; Chen, Guanqing; Yan, Hongge; Su, Bin; Gong, Xiaole; Zhou, Bo

    2017-09-01

    Microstructure and corrosion resistance in Hank's solution of four magnesium alloys (pure Mg, ZK60, Mg-4Zn and Mg-4Zn-0.3Ca) prepared by high strain rate rolling (HSRR) and conventional rolling (CR) are comparatively investigated. The HSRR alloy exhibits better bio-corrosion resistance than the CR alloy. The HSRR ZK60 alloy has finer grains, higher dynamic recrystallization (DRX) extent, lower twin fraction, coarser residual second-phase particles, finer and denser nanometer β 1 precipitates, lower residual compressive stress and stronger basal texture than the CR alloy. The average corrosion rate of the HSRR ZK60 sheet after 90-day immersion in Hank's solution is 0.17 mg cm-2 d-1, about 19% lower than that of the CR sheet. Its corrosion current density is 30.9 μA/cm2, about 45% lower than that of the CR sheet. Bio-corrosion resistance enhancement by HSRR can be mainly ascribe to the reduced grain size, the relatively adequate DRX, non-twinning, the coarser residual second-phase particles, the finer and denser nanometer precipitates and the slightly stronger (0001) texture.

  17. A corrosion resistant cerium oxide based coating on aluminum alloy 2024 prepared by brush plating

    Energy Technology Data Exchange (ETDEWEB)

    Tang Junlei; Han Zhongzhi [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Zuo Yu, E-mail: zuoy@mail.buct.edu.cn [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Tang Yuming [School of Materials Science and Engineering, Beijing University of Chemical Technology, Beijing 100029 (China)

    2011-01-15

    Cerium oxide based coatings were prepared on AA2024 Al alloy by brush plating. The characteristic of this technology is that hydrogen peroxide, which usually causes the plating solution to be unstable, is not necessary in the plating electrolyte. The coating showed laminated structures and good adhesive strength with the substrate. X-ray diffraction and X-ray photoelectron spectroscopy analysis showed that the coatings were composed of Ce(III) and Ce(IV) oxides. The brush plated coatings on Al alloys improved corrosion resistance. The influence of plating parameters on structure and corrosion resistance of the cerium oxide based coating was studied.

  18. Effect of heat treatment on the corrosion resistance of modified aluminum-magnesium alloys in seawater

    Science.gov (United States)

    Ahmad, Z.; Aleem, A.

    1993-10-01

    Study of modified Al-2.5Mg alloys containing chromium, silica, iron, and manganese in various tempers (O, H-18, T-4, T-6, T-18, and H-34) has shown that their corrosion resistance is significantly altered by thermomechanical treatment and the beneficial effect of chromium on microstructural changes. Modified binary Al-2.5Mg alloys in the T-6 and T-4 tempers exhibit a higher resistance to corrosion in Arabian Gulf water than H-34 tempers due to the beneficial effect of chromium on microstructural changes.

  19. Phosphating process of AZ31 magnesium alloy and corrosion resistance of coatings

    Institute of Scientific and Technical Information of China (English)

    CHENG Ying-liang; WU Hai-lan; CHEN Zhen-hua; WANG Hui-min; LI Ling-ling

    2006-01-01

    Zinc phosphate films were formed on AZ31 magnesium alloy by immersing into a phosphatation bath to enhance the corrosion resistance of AZ31. Different films were prepared by changing the processing parameters such as immersing time and temperature. The corrosion protection of the coatings was studied by electrochemical measurements such as electrochemical impedance spectroscopy, potentiodynamic polarization curves, and the structure of the films were studied by metalloscopy and X-ray diffraction (XRD). The results show that, the film formed at 80 ℃, 10 min has the highest corrosion resistance. The XRD patterns show that the film consists of hopeite (Zn3(PO4)2·xH2O).

  20. Plasma Electrolytic Oxidation (PEO) Coatings on an A356 Alloy for Improved Corrosion and Wear Resistance

    Science.gov (United States)

    Peng, Zhijing

    Plasma electrolytic oxidizing (PEO) is an advanced technique that has been used to deposit thick and hard ceramic coatings on aluminium (Al) alloys. This work was however to use the PEO process to produce thin ceramic oxide coatings on an A356 Al alloy for improving corrosion and wear resistance of the alloy. Effects of current density and treatment time on surface morphologies and thickness of the PEO coatings were investigated. The improvement of galvanic corrosion properties of the coated A356 alloy vs. steel and carbon fibre were evaluated in E85 fuel or NaCl environments. Tribological properties of the coatings were studied with comparison to the uncoated A356 substrate and other commercially-used engine bore materials. The research results indicated that the PEO coatings could have excellent tribological and corrosion properties for aluminium engine applications.

  1. The Enhancement of Mg Corrosion Resistance by Alloying Mn and Laser-Melting

    Directory of Open Access Journals (Sweden)

    Youwen Yang

    2016-03-01

    Full Text Available Mg has been considered a promising biomaterial for bone implants. However, the poor corrosion resistance has become its main undesirable property. In this study, both alloying Mn and laser-melting were applied to enhance the Mg corrosion resistance. The corrosion resistance, mechanical properties, and microstructure of rapid laser-melted Mg-xMn (x = 0–3 wt % alloys were investigated. The alloys were composed of dendrite grains, and the grains size decreased with increasing Mn. Moreover, Mn could dissolve and induce the crystal lattice distortion of the Mg matrix during the solidification process. Mn ranging from 0–2 wt % dissolved completely due to rapid laser solidification. As Mn contents further increased up to 3 wt %, a small amount of Mn was left undissolved. The compressive strength of Mg-Mn alloys increased first (up to 2 wt % and then decreased with increasing Mn, while the hardness increased continuously. The refinement of grains and the increase in corrosion potential both made contributions to the enhancement of Mg corrosion resistance.

  2. Effects of porosity on corrosion resistance of Mg alloy foam produced by powder metallurgy technology

    Energy Technology Data Exchange (ETDEWEB)

    Aghion, E., E-mail: egyon@bgu.ac.il; Perez, Y.

    2014-10-15

    Magnesium alloy foams have the potential to serve as structural material for regular light-weight applications as well as for biodegradable scaffold implants. However, their main disadvantage relates to the high reactivity of magnesium and consequently their natural tendency to corrode in regular service conditions and in physiological environments. The present study aims at evaluating the effect of porosity on the corrosion resistance of MRI 201S magnesium alloy foams in 0.9% NaCl solution and in phosphate buffer saline solution as a simulated physiological electrolyte. The magnesium foams were produced by powder metallurgy technology using space-holding particles to control the porosity content. Machined chips were used as raw material for the production of Mg alloy powder by milling process. The microstructure of the foams was examined using optical and scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy analysis. The corrosion behavior was evaluated by immersion test and potentiodynamic polarization analysis. The results obtained clearly demonstrate that the porosity has a significant effect on the corrosion resistance of the tested foams. Foams with 14–19% porosity have a corrosion rate of 4–10 mcd and 7–15 mcd in NaCl and phosphate buffer saline solution, respectively, compared to only 0.10 mcd for the same alloy in as cast conditions. This increased corrosion degradation of the Mg foams by more than one order of magnitude compared to the cast alloy may limit their potential application in regular and physiological environments. - Highlights: • Porosity has a detrimental effect on corrosion resistance of MRI 201S Mg foams. • 14–19% porosity increases the corrosion rate by more than one order of magnitude. • Accelerated corrosion limits the use of foams in regular/physiological environments.

  3. Composition and corrosion resistance of cerium conversion films on 2195Al-Li alloy

    Institute of Scientific and Technical Information of China (English)

    SONG Dong; FENG Xingguo; SUN Mingren; MA Xinxin; TANG Guangze

    2012-01-01

    The Ce conversion films on 2195Al-Li alloy without and with post-treatment were studied and the corrosion resistance was evaluated as well.The surface morphology was observed by scanning electron microscopy (SEN),and the chemical composition was characterized by X-ray photoelectron spectroscopy (XPS).The corrosion behaviors of 2195Al-Li alloy and conversion coating were assessed by means of potentiodynamic polarization curves.The experimental results indicated that after post-treatment the surface quality was improved significantly.According to XPS,the conversion coating after post-treatment was mainly composed of CeO2,Ce2O3,Ce-OH and a little MoO3 and MoO2.The results of potentiodynamic polarization curves revealed that the conversion coating with post-treatment possessed better corrosion resistance than bare alloy and Ce conversion coating without post-treatment.

  4. Improvement on the Corrosion Resistance of AZ91D Magnesium Alloy by Aluminum Diffusion Coating

    Institute of Scientific and Technical Information of China (English)

    Hongwei HUO; Ying LI; Fuhui WANG

    2007-01-01

    By combination of magnetron sputtering deposition and vacuum annealing, an aluminum diffusion coating was prepared on the substrate of AZ91D alloy to improve its corrosion resistance. The microstructure and composition of the diffusion coating was investigated by scanning electron microscopy and X-ray diffraction. The diffusion coating was mainly comprised of β phase-Al12Mg17. The continuous immersion test in 3.5 wt pct neutral NaCl solution indicated that the specimen with diffusion coating had better corrosion resistance compared with the bare AZ91D alloy specimen. The potentiodynamic polarization measurement indicated that the diffusion coating could function as an effectively protective layer to reduce the corrosion rate of AZ91D alloy when exposed to 3.5 wt pct NaCl solution.

  5. New Low-Sn Zr Cladding Alloys with Excellent Autoclave Corrosion Resistance and High Strength

    Directory of Open Access Journals (Sweden)

    Ruiqian Zhang

    2017-04-01

    Full Text Available It is expected that low-Sn Zr alloys are a good candidate to improve the corrosion resistance of Zr cladding alloys in nuclear reactors, presenting excellent corrosion resistance and high strength. The present work developed a new alloy series of Zr-0.25Sn-0.36Fe-0.11Cr-xNb (x = 0.4~1.2 wt % to investigate the effect of Nb on autoclave corrosion resistance. Alloy ingots were prepared by non-consumable arc-melting, solid-solutioned, and then rolled into thin plates with a thickness of 0.7 mm. It was found that the designed low-Sn Zr alloys exhibit excellent corrosion resistances in three out of pile autoclave environments (distilled water at 633 K/18.6 MPa, 70 ppm LiOH solution at 633 K/18.6 MPa, and superheated water steam at 673 K/10.3 MPa, as demonstrated by the fact of the Zr-0.25Sn-0.36Fe-0.11Cr-0.6Nb alloy shows a corrosion weight gain ΔG = 46.3 mg/dm2 and a tensile strength of σUTS = 461 MPa following 100 days of exposure in water steam. The strength of the low-Sn Zr alloy with a higher Nb content (x = 1.2 wt % is enhanced up to 499 MPa, comparable to that of the reference high-Sn N36 alloy (Zr-1.0Sn-1.0Nb-0.25Fe, wt %. Although the strength improvement is at a slight expense of corrosion resistance with the increase of Nb, the corrosion resistance of the high-Nb alloy with x = 1.2 (ΔG = 90.4 mg/dm2 for 100-day exposure in the water steam is still better than that of N36 (ΔG = 103.4 mg/dm2.

  6. Evaluation of High Temperature Corrosion Resistance of Finned Tubes Made of Austenitic Steel And Nickel Alloys

    Directory of Open Access Journals (Sweden)

    Turowska A.

    2016-06-01

    Full Text Available The purpose of the paper was to evaluate the resistance to high temperature corrosion of laser welded joints of finned tubes made of austenitic steel (304,304H and nickel alloys (Inconel 600, Inconel 625. The scope of the paper covered the performance of corrosion resistance tests in the atmosphere of simulated exhaust gases of the following chemical composition: 0.2% HCl, 0.08% SO2, 9.0% O2 and N2 in the temperature of 800°C for 1000 hours. One found out that both tubes made of austenitic steel and those made of nickel alloy displayed good resistance to corrosion and could be applied in the energy industry.

  7. Development of microarc oxidation process to improve corrosion resistance on AZ91HP magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    ZHANG Rong-fa; SHAN Da-yong; HAN En-hou; GUO Shi-bo

    2006-01-01

    A new anodizing process,which does not contain chromate but can improve the corrosion resistance of magnesium alloys significantly,was developed using a microarc power supply. Surface morphology was observed and the coating was compact and ceramic-like. In addition,the corrosion resistance of samples before and after anodization by the new process and a method in US Patent 5470664 was compared by potentiodymaic polarization curves,electrochemical impedance spectroscopy (EIS) and salt spray test. The results show that the anodization can improve the corrosion resistance of magnesium alloy. The samples obtained by the new process and the method mentioned in the US Patent 5470664 achieve 9 and 7 rates after 336 h salt spray test,respectively.

  8. Microstructure and corrosion resistance of phytic acid conversion coatings for magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Cui Xiufang [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); State Key Laboratory for Corrosion and Protection, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Li Qingfen [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Li Ying; Wang Fuhui [State Key Laboratory for Corrosion and Protection, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Jin Guo [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China)], E-mail: jg97721@yahoo.com.cn; Ding Minghui [School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China)

    2008-12-30

    In this paper, a new innoxious and pollution-free chemical protective coating for magnesium alloys, phytic acid conversion coating, was prepared. The conversion coatings are found to have high cover ratio and no cracks are found by atomic force microscopes (AFM) and scanning electron microscopy (SEM). The main elements of the conversion coatings are Mg, Al, O, P and C by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). The chemical state of the elements in the coatings was also investigated by Fourier transform infrared spectroscopy (FTIR). AES depth profile analysis suggests that the thickness of the conversion coating is about 340 nm. The corrosion resistance of the coatings was evaluated by polarization curves. The results indicate that the corrosion resistance for the conversion coated AZ91D magnesium alloys in 3.5% NaCl solution increases markedly. The mechanisms of corrosion resistance and coatings formation are also discussed.

  9. Microstructure and corrosion resistance of phytic acid conversion coatings for magnesium alloy

    Science.gov (United States)

    Cui, Xiufang; Li, Qingfen; Li, Ying; Wang, Fuhui; Jin, Guo; Ding, Minghui

    2008-12-01

    In this paper, a new innoxious and pollution-free chemical protective coating for magnesium alloys, phytic acid conversion coating, was prepared. The conversion coatings are found to have high cover ratio and no cracks are found by atomic force microscopes (AFM) and scanning electron microscopy (SEM). The main elements of the conversion coatings are Mg, Al, O, P and C by X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). The chemical state of the elements in the coatings was also investigated by Fourier transform infrared spectroscopy (FTIR). AES depth profile analysis suggests that the thickness of the conversion coating is about 340 nm. The corrosion resistance of the coatings was evaluated by polarization curves. The results indicate that the corrosion resistance for the conversion coated AZ91D magnesium alloys in 3.5% NaCl solution increases markedly. The mechanisms of corrosion resistance and coatings formation are also discussed.

  10. Corrosion resistant Zn–Co alloy coatings deposited using saw-tooth current pulse

    Indian Academy of Sciences (India)

    S Yogesha; A Chitharanjan Hegde

    2011-12-01

    Micro/nanostructured multilayer coatings of Zn–Co alloy were developed periodically on mild steel from acid chloride bath. Composition modulated multilayer alloy (CMMA) coatings, having gradual change in composition (in each layer) were developed galvanostatically using saw-tooth pulses through single bath technique (SBT). CMMA coatings were developed under different conditions of cyclic cathode current densities (CCCDs) and number of layers, and their corrosion resistances were evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) method. Optimal configuration, represented as (Zn–Co)2.0/4.0/300 was found to exhibit ∼ 89 times better corrosion resistance compared to monolithic (Zn–Co)3.0 alloy deposited for same time, from same bath. The better corrosion resistance of CMMA coatings was attributed to changed interfacial dielectric properties, evidenced by dielectric spectroscopy. Improved corrosion resistance was attributed to formation of -type semiconductor film at the interface, supported by the Mott–Schottky plot. Further, the formation of multilayer and corrosion mechanism was analysed using scanning electron microscopy (SEM).

  11. Protection of 2024-T3 aluminium alloy by corrosion resistant phytic acid conversion coating

    Science.gov (United States)

    Shi, Hongwei; Han, En-Hou; Liu, Fuchun; Kallip, Silvar

    2013-09-01

    The corrosion protection properties of environmentally friendly phytic acid conversion coatings were studied on 2024-T3 aluminium alloy. The films were prepared under acidic conditions with various pH values and characterised by SEM, EDS, ATR-FTIR and electrochemical techniques. The results indicate that the conversion coatings obtained by immersing the alloy in phytic acid solutions at pH from 3 to 5.5 provide excellent corrosion resistance. ATR-FTIR confirms that the film is formed by deposition of reaction products between Al3+ and phosphate groups in phytic acid molecules. The conformation models of the deposition film are proposed.

  12. Influence of silicon addition on the mechanical properties and corrosion resistance of low-alloy steel

    Indian Academy of Sciences (India)

    M Hebda; H Dębecka; J Kazior

    2015-12-01

    The addition of silicon to low-alloy steel allows to modify the materials' microstructure and thus to improve their corrosion resistance and mechanical properties. The influence of adding different amounts of silicon on the properties (density, transverse rupture strength, microhardness and corrosion resistance) and microstructure of low-alloy steel was investigated. Samples were prepared via the mechanical alloying process, which is the most useful method to homogeneously introduce silicon to low-alloy steel. Sintering was performed by using the spark plasma sintering (SPS) technique. After the SPS process, half of each of the obtained samples was heat-treated in a vacuum furnace. The results show that high-density materials were achieved, and a homogeneous and fine microstructure was obtained. The investigated compositions containing 1 wt% of silicon had better corrosion resistance than samples with 3 wt% of silicon addition. Furthermore, corrosion resistance as well as the mechanical and plastic properties of the samples with 1 wt% of silicon can be further improved by applying heat treatment.

  13. Effects of Solution and Aging Treatments on Corrosion Resistance of As-cast 60NiTi Alloy

    Science.gov (United States)

    Qin, Qiuhui; Wen, Yuhua; Wang, Gaixia; Zhang, Lanhui

    2016-12-01

    60NiTi alloy has become a competitive candidate for bearing applications due to its shape memory effect, superelasticity, high strength, hardness, excellent abrasion resistance and corrosion resistance, etc. However, the relationship between its corrosion resistance and heat treatment is not clearly understood. Therefore, we used OM, XRD, SEM and EDS to study the evolution of microstructure in as-cast, solution-treated and aged 60NiTi alloy. Besides, the potentiodynamic polarization and salt spray test were used to compare corrosion resistance of 60NiTi alloy and 316 stainless steel and to study the effect of microstructures on corrosion resistance of 60NiTi alloy. The results show that the corrosion resistance of as-cast 60NiTi alloy is comparable to that of 316 stainless steel, but the corrosion resistance of solution-treated and aged 60NiTi alloys is much superior. The significantly reduced Ni3Ti phase after the solution and aging treatments is responsible for the remarkable improvement in the corrosion resistance of as-cast 60NiTi alloy.

  14. Stress corrosion cracking resistance of aluminum alloy 7000 series after two-step aging

    Directory of Open Access Journals (Sweden)

    Jegdić Bore V.

    2015-01-01

    Full Text Available The effect of one step-and a new (short two-step aging on the resistance to stress corrosion cracking of an aluminum alloy 7000 series was investigated, using slow strain rate test and fracture mechanics method. Aging level in the tested alloy was evaluated by means of scanning electron microscopy and measurements of electrical resistivity. It was shown that the alloy after the new two-step aging is significantly more resistant to stress corrosion cracking. Values of tensile properties and fracture toughness are similar for both thermal states. Processes that take place at the crack tip have been considered. The effect of the testing solution temperature on the crack growth rate on the plateau was determined. Two values of the apparent activation energy were obtained. These values correspond to different processes that control crack growth rate on the plateau at higher and lower temperatures. [Projekat Ministarstva nauke Republike Srbije, br. TR 34028 i br. TR 34016

  15. XPS study of the corrosion resisting composite alloying layer obtained by double glow plasma with the brush plating Ni interlayer

    Institute of Scientific and Technical Information of China (English)

    Jiang Xu; Xishan Xie; Zhong Xu; Wenjin Liu

    2004-01-01

    The Ni-Cr-Mo-Cu multi-element surface alloying with the electric brush plating Ni interlayer on the low carbon steel substrate has been investigated. By the electrochemical method in 3.5% (mass fraction) NaC1 solution, the corrosion resistance of the composite alloying layer and single alloying layer is determined. The experimental results show that the corrosion resistance of the composite alloying layer is obviously better than that of the single alloying layer. The structure and composition of passive films formed on the two kinds of alloyed layers after electrochemical tests in 3.5% NaC1 solution have been studied using X-ray photoelectron spectroscopy (XPS). It is concluded that the double glow plasma surface alloying of low carbon steel with the electric brush plating Ni interlayer is an appropriate technique to enhance the corrosion resistance compared with the single double glow surface alloying.

  16. [Effect of titanium nitride coating on bacterial corrosion resistance of dental Co-Cr alloy].

    Science.gov (United States)

    Zou, Jie; Chen, Jie; Hu, Bin

    2010-04-01

    To study the influence of titanium nitride(TiN) coating on bacterial corrosion resistance of clinically used Co-Cr alloy. The Co-Cr alloy commonly used for casting metal full crown was casted with specimen 10mm x 10mm x 3mm in size. The specimen was coated with a thickness of 2.5 microm TiN coating on the surface by multi-arc physical vapor deposition. Then the specimen before and after coating titanium nitride were exposed to TSB media with S.mutans or Actinomyces viscosus,while pure media,as control.After inoculated for 24 hours, the Tafel polarization curves of the specimen were measured by electrochemical station. From the Tafel polarization curves, the non-coated Co-Cr alloy showed that corrosion potential moved to the negative way in presence of oral bacteria,and passivation interval got shorter.While the polarization curves of the specimen after coating TiN changed slightly in presence of oral microorganism. The TiN significantly weakened the corrosion action of bacteria on the alloy. These results demonstrate that the TiN coating with better tolerance to the bacterial action can improve bacterial corrosion resistance of Co-Cr alloy.Supported by Research Fund of Science and Technology Commission of Shanghai Municipality(Grant No.08DZ2271100) and Shanghai Leading Academic Discipline Project (Grant No. S30206).

  17. Mechanical properties and corrosion resistance of hot extruded Mg–2.5Zn–1Ca alloy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Dexue, E-mail: dexeliu@hotmail.com [State Key Laboratory of Advanced Processing and Recycling of Non-Ferrous Metals, Lanzhou University of Technology, Lanzhou 730050 (China); Department of Mechanical and Aerospace Engineering, University of California, San Diego, CA 92093-0411 (United States); Guo, Chenggong; Chai, Liqiang [State Key Laboratory of Advanced Processing and Recycling of Non-Ferrous Metals, Lanzhou University of Technology, Lanzhou 730050 (China); Sherman, Vincent R. [Department of Mechanical and Aerospace Engineering, University of California, San Diego, CA 92093-0411 (United States); Qin, Xiaoqiong; Ding, Yutian [State Key Laboratory of Advanced Processing and Recycling of Non-Ferrous Metals, Lanzhou University of Technology, Lanzhou 730050 (China); Meyers, Marc A. [Department of Mechanical and Aerospace Engineering, University of California, San Diego, CA 92093-0411 (United States)

    2015-05-15

    Highlights: • MgZnCa alloy was extruded into precise microtube for resorbable stent applications. • Interconnection between micro-structure and corrosion properties was revealed. • Both strength and ductility were simultaneously improved by processing sequence. • Better corrosion resistance in PBS solution was achieved after grain refining. - Abstract: It is demonstrated that the mechanical properties and corrosion resistance of Mg–2.5 wt%Zn–1 wt%Ca alloy are enhanced by the microstructural changes imparted by hot extrusion. A processing procedure is developed to form hollow tubes with an outer diameter of ∼2.0 mm and wall thickness of ∼0.1 mm, which is well suited for subsequent stent manufacturing. The influence of thermal and mechanical processing on corrosion and plasticity was found to be associated with grain-size reduction and the redistribution of intermetallic particles within the microstructure, providing significant improvement of performance over the cast alloy. Observation of the fracture surfaces reveals a mode transition from brittle (cast) to ductile (processed). Enhanced mechanical properties and decreased resorption rate represent significantly improved performance of this alloy after the novel processing sequence. Based on the improved properties, the produced Mg alloy is more suitable for practical in vivo applications.

  18. Plasma electrolytic oxidation coating on AZ91 magnesium alloy modified by neodymium and its corrosion resistance

    Science.gov (United States)

    Song, Y. L.; Liu, Y. H.; Yu, S. R.; Zhu, X. Y.; Wang, Q.

    2008-03-01

    Ceramic coatings on the surfaces of Mg-9Al-1Zn (AZ91) magnesium alloy and Mg-9Al-1Zn-1Nd magnesium alloy (AZ91 magnesium alloy modified by neodymium, named as AZ91Nd in this paper) are synthesized in aluminate electrolyte by plasma electrolytic oxidation (PEO) process, respectively. X-ray diffraction and X-ray photoelectron spectroscopy analyses show the PEO coating on the Mg-9Al-1Zn-1Nd alloy comprises not only MgO and Al 2O 3, which are found in the coating on the AZ91 alloy, but also a trace amount of Nd 2O 3. Microstructure observations indicate the addition of Nd can decrease the sizes of β phases and form Al 2Nd intermetallics in the AZ91 alloy. The fine β phases can effectively restrain the formation of unclosed-holes and greatly decrease the sizes of pores in the coating during the PEO process. In addition, the Al 2Nd intermetallics can be completely covered due to the lateral growth of the PEO coatings formed on the α and β phases. As a result, the coating on the AZ91Nd alloy possesses a dense microstructure compared with that on the AZ91 alloy. The following corrosion tests indicate the corrosion resistance of the PEO coating on the AZ91Nd alloy is evidently higher than that of the PEO coating on the AZ91 alloy.

  19. INFLUENCE OF PHOSPHATIZED SURFACE LAYER ON CORROSION RESISTANCE OF Mg-Al-RE ALLOY

    Directory of Open Access Journals (Sweden)

    Katarína Miková

    2015-09-01

    Full Text Available This contribution deals with evaluation of the corrosion resistance of extruded Mg-2Al-1RE (AE21 magnesium alloy in the state before and after treatment of ground surface by selected phosphatizing procedure. Specimens were exposed to 0.1M NaCl solution for several time periods starting from 5 minutes up-to 168 hours at room temperature of 22 ± 1 °C. Afterwards electrochemical impedance spectroscopy was carried out on the exposed specimens. Based on the results obtained from the electrochemical tests and visual observation of corrosion attack progress, positive or negative impact of selected phosphating process on the corrosion resistance of Mg-2Al-1RE magnesium alloy under given conditions was assessed.

  20. Corrosion resistance of Mg-Mn-Ce magnesium alloy modified by polymer plating

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Polymeric nano-film on the surface of Mg-Mn-Ce magnesium alloy was fabricated by polymer plating of 6-dihexylamino-1,3,5-triazine-2,4-dithiol monosodium(DHN)to improve its corrosion resistance.The electrochemical reaction process was analyzed by cyclic voltammetry and two obvious peaks of oxidation reaction were observed.The static contact angle of distilled water on polymer-plated surface can be up to 106.3°while on the blank surface it is 45.8°.Potentiodynamic polarization results show that the polymeric film Can increase the corrosion potential from-1.594 V VS SCE for blank to-0.382 V VS SCE.The results of electrochemical impedance spectroscopy indicate that the charge transfer resistances of blank and polymer-plated fabricating hydrophobic film on Mg-Mn-Ce alloy surface and improving its anti-corrosion property.

  1. Formation and Corrosion Resistance of Mg-Al Hydrotalcite Film on Mg-Gd-Zn Alloy

    Science.gov (United States)

    Ba, Z. X.; Dong, Q. S.; Kong, S. X.; Zhang, X. B.; Xue, Y. J.; Chen, Y. J.

    2017-06-01

    An environment-friendly technique for depositing a Mg-Al hydrotalcite (HT) (Mg6Al2(OH)16-CO3ṡ4H2O) conversion film was developed to protect the Mg-Gd-Zn alloy from corrosion. The morphology and chemical compositions of the film were analyzed by scanning electronic microscope (SEM) equipped with energy dispersive X-ray spectroscopy (EDS), X-ray diffraction (XRD) and Raman spectroscopy (RS), respectively. The electrochemical test and hydrogen evolution test were employed to evaluate the biocorrosion behavior of Mg-Gd-Zn alloy coated with the Mg-Al HT film in the simulated body fluid (SBF). It was found that the formation of Mg-Al HT film was a transition from amorphous precursor to a crystalline HT structure. The HT film can effectively improve the corrosion resistance of magnesium alloy. It indicates that the process provides a promising approach to modify Mg-Gd-Zn alloy.

  2. Effect of Mn Content and Solution Annealing Temperature on the Corrosion Resistance of Stainless Steel Alloys

    Directory of Open Access Journals (Sweden)

    Ihsan-ul-Haq Toor

    2014-01-01

    Full Text Available The corrosion behavior of two specially designed austenitic stainless steels (SSs having different Nickel (Ni and Manganese (Mn contents was investigated. Prior to electrochemical tests, SS alloys were solution-annealed at two different temperatures, that is, at 1030°C for 2 h and 1050°C for 0.5 h. Potentiodynamic polarization (PD tests were carried out in chloride and acidic chloride, whereas linear polarization resistance (LPR and electrochemical impedance spectroscopy (EIS was performed in 0.5 M NaCl solution at room temperature. SEM/EDS investigations were carried out to study the microstructure and types of inclusions present in these alloys. Experimental results suggested that the alloy with highest Ni content and annealed at 1050°C/0.5 hr has the highest corrosion resistance.

  3. Electrodeposition, Structure and Corrosion Resistance of Nanocrystalline Ni-W Alloy

    Institute of Scientific and Technical Information of China (English)

    YANG, Fang-Zu(杨防祖); GUO, Yi-Fei(郭逸飞); HUANG, Ling(黄令); XU, Shu-Kai(许书楷); ZHOU, Shao-Min(周绍民)

    2004-01-01

    Ni-W alloy was electrodeposited from the electrolyte solution containing sodium tungstate, nickel sulfate and ammonium citrate. The electrodeposition, heat treatment, structure, surface morphology and corrosion resistance in w=0.03 NaCl solution, of Ni-W alloys were studied by means of DSC, XRD, SEM and electrochemical techniques. The results showed that the obtained Ni-W alloy electrodeposit with W weight content (wW=0.471) was presented in more typical nanocrystalline. After heat treatment at 400 ℃ for 1 h, the phase structure of the deposits was not obviously changed whereas the agglomerate for the reunion of tiny grains on deposit surface caused the granule in a more smooth morphology, the microhardness was slightly increased and the corrosion resistance was enhanced.

  4. SHOT PEENING INFLUENCE ON CORROSION RESISTANCE OF AE21 MAGNESIUM ALLOY

    Directory of Open Access Journals (Sweden)

    Branislav Hadzima

    2010-12-01

    Full Text Available Evaluation of the electrochemical characteristics of the AE21 magnesium alloy is presented in the article. The surfaces of tested alloys were treated by grinding and grinding followed by sodium bicarbonate shot-peening. The specimens were evaluated by electrochemical impedance spectroscopy method in combination with exposure tests in 0.1 NaCl solution. The exposition times were from 5 minutes to 168 hours. The measured data were analysed using equivalent circuits and polarization resistances of the various corrosion systems were determined. Results of the electrochemical measurements are complemented by metallographical evaluation of the tested alloy.

  5. Improving Corrosion Resistance and Biocompatibility of Magnesium Alloy by Sodium Hydroxide and Hydrofluoric Acid Treatments

    Directory of Open Access Journals (Sweden)

    Chang-Jiang Pan

    2016-12-01

    Full Text Available Owing to excellent mechanical property and biodegradation, magnesium-based alloys have been widely investigated for temporary implants such as cardiovascular stent and bone graft; however, the fast biodegradation in physiological environment and the limited surface biocompatibility hinder their clinical applications. In the present study, magnesium alloy was treated by sodium hydroxide (NaOH and hydrogen fluoride (HF solutions, respectively, to produce the chemical conversion layers with the aim of improving the corrosion resistance and biocompatibility. The results of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR and X-ray photoelectron spectroscopy (XPS indicated that the chemical conversion layers of magnesium hydroxide or magnesium fluoride were obtained successfully. Sodium hydroxide treatment can significantly enhance the surface hydrophilicity while hydrogen fluoride treatment improved the surface hydrophobicity. Both the chemical conversion layers can obviously improve the corrosion resistance of the pristine magnesium alloy. Due to the hydrophobicity of magnesium fluoride, HF-treated magnesium alloy showed the relative better corrosion resistance than that of NaOH-treated substrate. According to the results of hemolysis assay and platelet adhesion, the chemical surface modified samples exhibited improved blood compatibility as compared to the pristine magnesium alloy. Furthermore, the chemical surface modified samples improved cytocompatibility to endothelial cells, the cells had better cell adhesion and proliferative profiles on the modified surfaces. Due to the excellent hydrophilicity, the NaOH-treated substrate displayed better blood compatibility and cytocompatibility to endothelial cells than that of HF-treated sample. It was considered that the method of the present study can be used for the surface modification of the magnesium alloy to enhance the corrosion resistance and biocompatibility.

  6. [Effects of TiSi coating on corrosion resistance of dental Co-Cr alloy].

    Science.gov (United States)

    Hu, Bin; Chen, Jie; Zhang, Fu-qiang

    2011-12-01

    To investigate the effect of titanium-silicon(TiSi) coating on corrosion resistance of dental CoCr alloy. The commonly used CoCr alloy was cast into 10mm×10mm×3mm specimen in size. Then the specimen was coated with TiSi on the surface by sol-gel method. The specimens were immersed in artificial saliva. Weight loss method was used to analyze corrosion rate. Element analysis using Auger Electron Spectroscopy (AES) was performed to compare the content of element before and after coating of TiSi in artificial saliva. SAS8.0 software package was used for statistical analysis. By weight lost method, before and after coating TiSi, the corrosive rate was 0.163 g·m(-2)·h(-1) and 0.138 g·m(-2)·h(-1) respectively. With AES, in Co-Cr alloy not coating TiSi, atomic concentration (g·m(-2)) of Ni, Co, Cr and Si was 7.728582657,0.008801153,0.306195965 and 0.194851978,respectively. After coating Ti-Si,the content of Ni, Co, Cr and Si and 4.745189808,0.004718889, 0.153195362 and 0.778406136, respectively. The release rate of the Ni,Co,cr were decreased after coating. TiSi coating can improve corrosion resistance of CoCr alloy.

  7. Thermal Aging Effect on Corrosion Resistance in Fusion Boundary of A533 Gr. B and Alloy 152

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Kyoung Joon; Yoo, Seung Chang; Kim, Taeho; Ham, Junhyuk; Kim, Ji Hyun [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Dissimilar metal weldment (DMW) is frequently used for joining low-alloy steel pressure vessel nozzles and steam generator nozzles to nickel-based wrought alloy or austenitic stainless steel components in high energy systems. This feature also significantly hinders C diffusion from the ferrite base metal to the weld metal. Until now, stress corrosion cracking has not occurred in DMWs where a High-Cr weld metal (such as Alloy 152 or Alloy 690), which is Ni-base weld metal including relative high Cr, is used as the weld metal in the weld between the nickel-based alloy and low-alloy steel. To understand the microstructure and corrosion evolution on fusion boundary between low-alloy steel and Ni-base weld metal, microstructural analysis and polarization test were performed with A533 Gr. B/Alloy 152/Alloy 690. Remarkable changes were observed in corrosion resistance and hardness at fusion boundary between low-alloy steel and Ni-base weld metal. The precipitate, which has different potential with peripheral region, can cause galvanic corrosion or pitting corrosion and is the one of hardening methods by disturbing movement of the dislocation. At initial step of heat treatment, the number of precipitates was increased. In fusion boundary between A533 Gr. B and Alloy 152, the corrosion resistance was decreased, and the hardness was increased. Next, at further step, the number of precipitates.

  8. Multiscale Electrochemical Investigation of the Corrosion Resistance of Various Alloys Used in Dental Prostheses

    Science.gov (United States)

    Iacoban, Sorin; Mareci, Daniel; Bolat, Georgiana; Munteanu, Corneliu; Souto, Ricardo Manuel

    2015-04-01

    The electrochemical behavior of Ag-Pd (Paliag), Ni-Cr (Heraenium NA), and Co-Cr (Heraenium CE) alloys used in dental prosthetics construction of crowns and bridges was studied in 0.9 pct NaCl solution at 298 K (25 °C). The localized electrochemical characteristics related to corrosion resistance and eventual breakdown of the protecting oxide layers were investigated by scanning electrochemical microscopy (SECM), whereas potentiodynamic polarization and electrochemical impedance spectroscopy techniques were employed to establish oxide stability. When the corrosion resistance of the alloys was evaluated by means of the corrosion current value determined around their corresponding open circuit potential in 0.9 pct NaCl solution, good protection can be expected resulting from their spontaneous passivation (low current densities in the order of tenths of μA cm-2). The polarization resistance of all the samples increased with immersion time, in the sequence Ag-Pd human body. Although a passivation mechanism was still operating in the chromium-containing alloys, oxide dissolution and precipitation of corrosion products occurred on Ag-Pd instead.

  9. Laser cladding of Zr-based coating on AZ91D magnesium alloy for improvement of wear and corrosion resistance

    Indian Academy of Sciences (India)

    Kaijin Huang; Xin Lin; Changsheng Xie; T M Yue

    2013-02-01

    To improve the wear and corrosion resistance of AZ91D magnesium alloy, Zr-based coating made of Zr powder was fabricated on AZ91D magnesium alloy by laser cladding. The microstructure of the coating was characterized by XRD, SEM and TEM techniques. The wear resistance of the coating was evaluated under dry sliding wear test condition at room temperature. The corrosion resistance of the coating was tested in simulated body fluid. The results show that the coating mainly consists of Zr, zirconium oxides and Zr aluminides. The coating exhibits excellent wear resistance due to the high microhardness of the coating. The main wear mechanism of the coating and the AZ91D sample are different, the former is abrasive wear and the latter is adhesive wear. The coating compared to AZ91D magnesium alloy exhibits good corrosion resistance because of the good corrosion resistance of Zr, zirconium oxides and Zr aluminides in the coating.

  10. Effects of Alloy Element and Microstructure on Corrosion Resistant Property of Deposited Metals of Weathering Steel

    Institute of Scientific and Technical Information of China (English)

    Xiao-ming XIAO; Yun PENG; Cheng-yong MA; Zhi-ling TIAN

    2016-01-01

    Alloy element and microstructure are key factors that dominate mechanical and corrosion resistant properties of weathering steel.The effect of Mo on microstructure,mechanical properties and corrosion resistant property of depos-ited metal was investigated.Experimental results show that with the increase of Mo content in deposited metals,the phase transformation temperature decreases,and the ferrite zone in CCT diagram moves rightward,resulting in en-larged bainite zone and reduced ferrite and pearlite zone.The addition of 0�24 mass% Mo in deposited metal results in the increase of tensile strength,more M-A constituent and less high angle grain which reduce the low temperature toughness.It is found that Mo can raise the weathering resistance of deposited metal in industrial atmosphere.Analy-sis indicates that Mo may enrich in the inner rust layer,produce MoO3 ,enhance the formation of compact rust film and impede the anode dissolution reaction.Granular bainite in deposited metals displays better corrosion resistance than acicular ferrite during the initial corrosion stage,but its long-term influence on the corrosion resistance is limited.

  11. Influence of Processing and Heat Treatment on Corrosion Resistance and Properties of High Alloyed Steel Coatings

    Science.gov (United States)

    Hill, Horst; Weber, Sebastian; Raab, Ulrich; Theisen, Werner; Wagner, Lothar

    2012-09-01

    Corrosion and abrasive wear are two important aspects to be considered in numerous engineering applications. Looking at steels, high-chromium high-carbon tool steels are proper and cost-efficient materials. They can either be put into service as bulk materials or used as comparatively thin coatings to protect lower alloyed construction or heat treatable steels from wear and corrosion. In this study, two different corrosion resistant tool steels were used for the production of coatings and bulk material. They were processed by thermal spraying and super solidus liquid phase sintering as both processes can generally be applied to produce coatings on low alloyed substrates. Thermally sprayed (high velocity oxygen fuel) coatings were investigated in the as-processed state, which is the most commonly used condition for technical applications, and after a quenching and tempering treatment. In comparison, sintered steels were analyzed in the quenched and tempered condition only. Significant influence of alloy chemistry, processing route, and heat treatment on tribological properties was found. Experimental investigations were supported by computational thermodynamics aiming at an improvement of tribological and corrosive resistance.

  12. Enhanced corrosion resistance of magnesium alloy AM60 by cerium(III) in chloride solution

    Energy Technology Data Exchange (ETDEWEB)

    Heakal, F. El-Taib, E-mail: fakihaheakal@yahoo.com [Chemistry Department, Faculty of Science, Cairo University, Giza 12613 (Egypt); Shehata, O.S. [Physical Chemistry Department, National Research Centre, Dokki, Giza (Egypt); Tantawy, N.S. [Girl' s College of Arts, Science and Education, Ain Shams University, Asma Fahmi Street, Cairo (Egypt)

    2012-03-15

    Highlights: Black-Right-Pointing-Pointer Corrosion rate of AM60 in Cl{sup -} solution decreases with increasing [Ce{sup 3+}] up to 1 mM. Black-Right-Pointing-Pointer Beyond that level the corrosion rate increases and then stabilizes. Black-Right-Pointing-Pointer The spontaneously formed film characterises by increasing resistance with time. Black-Right-Pointing-Pointer The converted film after 10 d immersion exhibits self-healing in plain Cl{sup -} solution. Black-Right-Pointing-Pointer Ce(III) should be present in the corrodent to form a more compact surface coating. - Abstract: Cerium(III) was utilised to enhance the corrosion resistance of AM60 in NaCl solution. Ce{sup 3+} can suppress corrosion deterioration up to 1.0 mM. Beyond that level corrosion rate increases till a steady value. Surface film resistance increases with time evolution until 24 h, then decreases and stabilizes. The converted film after 240 h immersion exhibits self-healing and thickening when re-exposed to plain chloride solution. SEM and EDX confirmed that when Ce is present as additive in solution, more compact coating is formed better than its presence as a post coating on the alloy surface before being immersed in the corrosive environment.

  13. Corrosion resistance of biodegradable polymeric layer-by-layer coatings on magnesium alloy AZ31

    Science.gov (United States)

    Cui, Lan-Yue; Zeng, Rong-Chang; Zhu, Xiao-Xiao; Pang, Ting-Ting; Li, Shuo-Qi; Zhang, Fen

    2016-06-01

    Biocompatible polyelectrolyte multilayers (PEMs) and polysiloxane hybrid coatings were prepared to improve the corrosion resistance of biodegradable Mg alloy AZ31. The PEMs, which contained alternating poly(sodium 4-styrenesulfonate) (PSS) and poly(allylamine hydrochloride) (PAH), were first self-assembled on the surface of the AZ31 alloy substrate via electrostatic interactions, designated as (PAH/PSS)5/AZ31. Then, the (PAH/PSS)5/AZ31 samples were dipped into a methyltrimethoxysilane (MTMS) solution to fabricate the PMTMS films, designated as PMTMS/(PAH/PSS)5/AZ31. The surface morphologies, microstructures and chemical compositions of the films were investigated by FE-SEM, FTIR, XRD and XPS. Potentiodynamic polarization, electrochemical impedance spectroscopy and hydrogen evolution measurements demonstrated that the PMTMS/(PAH/PSS)5/AZ31 composite film significantly enhanced the corrosion resistance of the AZ31 alloy in Hank's balanced salt solution (HBSS). The PAH and PSS films effectively improved the deposition of Ca-P compounds including Ca3(PO4)2 and hydroxyapatite (HA). Moreover, the corrosion mechanism of the composite coating was discussed. These coatings could be an alternative candidate coating for biodegradable Mg alloys.

  14. Influence of the pulsed plasma treatment on the corrosion resistance of the low-alloy steel plated by Ni-based alloy

    Science.gov (United States)

    Dzhumaev, P.; Yakushin, V.; Kalin, B.; Polsky, V.; Yurlova, M.

    2016-04-01

    This paper presents investigation results of the influence of high temperature pulsed plasma flows (HTPPF) treatment on the corrosion resistance of low-alloy steel 0.2C-Cr-Mn- Ni-Mo cladded by the rapidly quenched nickel-based alloy. A technique that allows obtaining a defect-free clad layer with a good adhesion to the substrate was developed. It is shown that the preliminary treatment of steel samples by nitrogen plasma flows significantly increases their corrosion resistance in the conditions of intergranular corrosion test in a water solution of sulfuric acid. A change of the corrosion mechanism of the clad layer from intergranular to uniform corrosion was observed as a result of sub-microcrystalline structure formation and homogeneous distribution of alloying elements in the plasma treated surface layer thus leading to the significant increase of the corrosion resistance.

  15. Corrosion resistance of the soldering joint of post-soldering of palladium-based metal-ceramic alloys.

    Science.gov (United States)

    Kawada, E; Sakurai, Y; Oda, Y

    1997-05-01

    To evaluate the corrosion resistance of post soldering of metal-ceramic alloys, four commercially available palladium-system metal-ceramic alloys (Pd-Cu, Pd-Ni, Pd-Ag, and Pd-Sb systems) and two types of solder (12 k gold solder and 16 k gold solder) with different compositions and melting points were used. The corrosion resistance of the soldered joint was evaluated by anodic polarization. The electrochemical characteristics of soldered surface were measured using electrochemical equipment. Declines in corrosion resistance were not detectable with Pd-Cu, Pd-Ag and Pd-Sb types, but break down at low potential occurred with Pd-Ni type.

  16. Microstructure and Corrosion Resistance of Electrodeposited Ni-Cu-Mo Alloy Coatings

    Science.gov (United States)

    Meng, Xinjing; Shi, Xi; Zhong, Qingdong; Shu, Mingyong; Xu, Guanquan

    2016-09-01

    This paper deals with the electrodeposition of Ni-Cu-Mo ternary alloy coatings on low-carbon steel substrate from an aqueous citrate sulfate bath. The structures and microstructure of coatings were characterized by scanning electron microscopy and x-ray diffractometry. The corrosion resistance of coatings was investigated by potentiodynamic polarization (Tafel) and electrochemical impedance spectroscopy techniques. The results show that the Ni-Cu-Mo coatings are mainly composed of fcc-Ni phase and a small amount of NiCu phase. Ni-Cu-Mo coatings exhibit a nodular surface morphology, and the roughness of electroplated coating increases with the increasing of Na2MoO4·2H2O in the bath. The corrosion performance of the coatings is significantly affected by the Mo content of the alloy coating and their surface morphology. The coating prepared in bath containing 40 g/L Na2MoO4·2H2O has the highest corrosion resistance in 3.5 wt.% NaCl solution, while that prepared in bath containing 60 g/L (or more) Na2MoO4·2H2O shows a lower corrosion resistance due to the presence of microcracks on the coating surface.

  17. The oxidation and corrosion of ODS alloys

    Science.gov (United States)

    Lowell, Carl E.; Barrett, Charles A.

    1990-01-01

    The oxidation and hot corrosion of high temperature oxide dispersion strengthened (ODS) alloys are reviewed. The environmental resistance of such alloys are classified by oxide growth rate, oxide volatility, oxide spalling, and hot corrosion limitations. Also discussed are environmentally resistant coatings for ODS materials. It is concluded that ODS NiCrAl and FeCrAl alloys are highly oxidation and corrosion resistant and can probably be used uncoated.

  18. Oxidation And Hot Corrosion Of ODS Alloy

    Science.gov (United States)

    Lowell, Carl E.; Barrett, Charles A.

    1993-01-01

    Report reviews oxidation and hot corrosion of oxide-dispersion-strengthened (ODS) alloys, intended for use at high temperatures. Classifies environmental resistances of such alloys by rates of growth of oxides, volatilities of oxides, spalling of oxides, and limitations imposed by hot corrosion. Also discusses environmentally resistant coatings for ODS materials. Concludes ODS NICrAl and FeCrAl alloys highly resistant to oxidation and corrosion and can be used uncoated.

  19. Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints.

    Science.gov (United States)

    Zupancic, Rok; Legat, Andraz; Funduk, Nenad

    2006-10-01

    The longevity of prosthodontic restorations is often limited due to the mechanical or corrosive failure occurring at the sites where segments of a metal framework are joined together. The purpose of this study was to determine which joining method offers the best properties to cobalt-chromium alloy frameworks. Brazed and 2 types of laser-welded joints were compared for their mechanical and corrosion characteristics. Sixty-eight cylindrical cobalt-chromium dental alloy specimens, 35 mm long and 2 mm in diameter, were cast. Sixteen specimens were selected for electrochemical measurements in an artificial saliva solution and divided into 4 groups (n=4). In the intact group, the specimens were left as cast. The specimens of the remaining 3 groups were sectioned at the center, perpendicular to the long-axis, and were subsequently rejoined by brazing (brazing group) or laser welding using an X- or I-shaped joint design (X laser and I laser groups, respectively). Another 16 specimens were selected for electrochemical measurements in a more acidic artificial saliva solution. These specimens were also divided into 4 groups (n=4) as described above. Electrochemical impedance spectroscopy and potentiodynamic polarization were used to assess corrosion potentials, breakdown potentials, corrosion current densities, total impedances at lowest frequency, and polarization charge-transfer resistances. The remaining 36 specimens were used for tensile testing. They were divided into 3 groups in which specimen pairs (n=6) were joined by brazing or laser welding to form 70-mm-long cylindrical rods. The tensile strength (MPa) was measured using a universal testing machine. Differences between groups were analyzed using 1-way analysis of variance (alpha=.05). The fracture surfaces and corrosion defects were examined with a scanning electron microscope. The average tensile strength of brazed joints was 792 MPa and was significantly greater (P<.05) than the tensile strength of both types of

  20. Improving corrosion resistance of RE-containing magnesium alloy ZE41A through ECAP

    Institute of Scientific and Technical Information of China (English)

    JIANG; Jinghua; MA; Aibin

    2009-01-01

    Significant grain refinement was achieved in rare earth (RE) containing aeronautic magnesium alloy ZE41A through equal-chan-nel angular pressing (ECAP) using rotary die at 603 K. Influence of ECAP pass number on its microstructure change and corrosion behavior was investigated by optical microscope (OM)/scanning electron microscope (SEM) observation and potentiostatic polarization tests in aque-otis solution of NaCl, respectively. The results showed that ultrafine equiaxial grains (about 2.5 μm) were obtained over 16 passes due to plastic-induced grain refinement accommodated by dynamic recrystallization. The lower corrosion current density and nobler corrosion po-tential correlated with large number of pressing passes were attributed to the low tendency toward localized corrosion with broken secondary phase after homogenization on ultrafine-grained Mg matrix. The multi-pass ECAP method made the ZE41A aeronautic magnesium alloy more attractive since severe plastic deformation may significandy improve its corrosion resistance besides superior mechanical properties.

  1. Development in corrosion resistance by microstructural refinement in Zr-16 SS 304 alloy using suction casting technique

    Energy Technology Data Exchange (ETDEWEB)

    Das, N., E-mail: nirupamd@barc.gov.in; Sengupta, P.; Abraham, G.; Arya, A.; Kain, V.; Dey, G.K.

    2016-08-15

    Highlights: • Grain refinement was made in Zr–16 wt.% SS alloy while prepared by suction casting process. • Distribution of Laves phase, e.g., Zr{sub 2}(Fe, Cr) was raised in suction cast (SC) Zr–16 wt.% SS. • Corrosion resistance was improved in SC alloy compared to that of arc-melt-cast alloy. • Grain refinement in SC alloy assisted for an increase in its corrosion resistance. - Abstract: Zirconium (Zr)-stainless steel (SS) hybrid alloys are being considered as baseline alloys for developing metallic-waste-form (MWF) with the motivation of disposing of Zr and SS base nuclear metallic wastes. Zr–16 wt.% SS, a MWF alloy optimized from previous studies, exhibit significant grain refinement and changes in phase assemblages (soft phase: Zr{sub 2}(Fe, Cr)/α-Zr vs. hard phase: Zr{sub 3}(Fe, Ni)) when prepared by suction casting (SC) technique in comparison to arc-cast-melt (AMC) route. Variation in Cr-distribution among different phases are found to be low in suction cast alloy, which along with grain refinement restricted Cr-depletion at the Zr{sub 2}(Fe, Cr)/Zr interfaces, prone to localized attack. Hence, SC alloy, compared to AMC alloy, showed lower current density, higher potential at the breakdown of passivity and higher corrosion potential during polarization experiments (carried out under possible geological repository environments, viz., pH 8, 5 and 1) indicating its superior corrosion resistance.

  2. Laser Cladding of an Al-11.7Wt% Si Alloy on ZM5 Magnesium Alloy to Enhance the Corrosion Resistance

    Institute of Scientific and Technical Information of China (English)

    CHEN Chang-jun; WANG Mao-cai; WANG Dong-sheng

    2004-01-01

    Magnesium alloy is an important engineering materials, but the wider application is restricted by poor corrosion resistance. An attempt was made to enhance the corrosion resistance and microhardness of a Mg-Al base ZM5 alloy by laser cladding of Al-11.7Wt%Si alloy powder with thickness 1.1mm and 1.7mm. The microstructure, phase and corrosion properties were analyzed by scanning electron micrographic (SEM), electron probe microanalysis(EPMA), vicker hardness tester and corrosion measurement system, respectively. Microhardness of the cladding layer was enhanced to 150-375Hv as compared to 60-99Hv of the substrate. The corrosion potential (Ecorr) of the cladding sample was 80mv higher than the substrate, while the corrosion current (Icorr) was lower than the substrate.

  3. Laser Cladding of an Al-11.7Wt% Si Alloy on ZM5 Magnesium Alloy to Enhance the Corrosion Resistance

    Institute of Scientific and Technical Information of China (English)

    CHENChang-jun; WANGMao-cai; WANGDong-sheng

    2004-01-01

    Magnesium alloy is an important engineering materials, but the wider application is restricted by poor corrosion resistance. An attempt was made to enhance the corrosion resistance and microhardness of a Mg-Al base ZM5 alloy by laser cladding of A1-11.7Wt%Si alloy powder with thickness 1.1 mm and 1.7inm. The microstructure, phase and corrosion properties were analyzed by scanning electron micrographic (SEM), electron probe microanalysis(EPMA), vicker hardness tester and corrosion measurement system, respectively. Microhardness of the cladding layer was enhanced to 150-375Hv as compared to 60-99Hv of the substrate. The corrosion potential (Ecorr) of the cladding sample was 80mv higher than the substrate, while the corrosion current (lcorr) was lower than the substrate.

  4. Grain boundary network control and its effect on intergranular corrosion resistance of Alloy 690

    Energy Technology Data Exchange (ETDEWEB)

    Shuang Xia; Hui Li; Chang Liang Hu; Ting Guang Lui; Bang Xin Zhou; Wen Jue Chen [Institute of Materials, Shanghai University, P.O. Box 269, 149 Yanchang Road (China)

    2011-07-01

    Grain boundary engineering was carried out in Alloy 690 tube sample and its effect on the intergranular corrosion resistance was investigated. Through small amount of deformation by cold drawing and short time annealing at high temperature, the proportion of low {Sigma} coincidence site lattice (CSL) grain boundaries of the Alloy 690 tube sample can be enhanced to about 75% which mainly were of {Sigma}3{sup n} (n = 1, 2, 3...) type. In this case, the grain boundary network (GBN) was featured by the formation of large grain-clusters produced by multiple twinning during recrystallization. All of the grains inside this kind of cluster had {Sigma}3{sup n} mutual mis-orientations, and hence all the boundaries inside the cluster were of {Sigma}3{sup n} type and form many interconnected {Sigma}3{sup n} type triple junctions. The weight losses due to grain dropping during intergranular corrosion for the samples with the modified GBN were much less than that with conventional microstructure. Based on the characterization by scanning electron microscope (SEM) and electron backscatter diffraction (EBSD) technique, it was shown that the large grain-cluster microstructure played a key role in enhancing the intergranular corrosion resistance: 1) the large grain-cluster can arrest the penetration of intergranular corrosion; 2) the large grain-cluster can protect the under layer microstructure. (authors)

  5. Improvement of mechanical properties and corrosion resistance of biodegradable Mg-Nd-Zn-Zr alloys by double extrusion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiaobo, E-mail: xbxbzhang2003@163.com [School of Materials Science and Engineering, Nanjing Institute of Technology, Nanjing, 211167 (China); Wang, Zhangzhong [School of Materials Science and Engineering, Nanjing Institute of Technology, Nanjing, 211167 (China); Yuan, Guangyin [National Engineering Research Center of Light Alloy Net Forming, Shanghai Jiao Tong University, Shanghai, 200240 (China); Xue, Yajun [School of Materials Science and Engineering, Nanjing Institute of Technology, Nanjing, 211167 (China)

    2012-08-01

    Highlights: Black-Right-Pointing-Pointer Microstructure of Mg-Nd-Zn-Zr alloys was refined and homogenized by double extrusion process. Black-Right-Pointing-Pointer The mechanical properties of the alloys were significantly enhanced by double extrusion. Black-Right-Pointing-Pointer The biocorrosion resistance of the alloys was improved by double extrusion. - Abstract: Mg-Nd-Zn-Zr alloy is a novel and promising biodegradable magnesium alloy due to good biocompatibility, desired uniform corrosion mode and outstanding corrosion resistance in simulated body fluid (SBF). However, the corrosion resistance and mechanical properties should be improved to meet the requirement of the biodegradable implants, such as plates, screws and cardiovascular stents. In the present study, double extrusion process was adopted to refine microstructure and improve mechanical properties of Mg-2.25Nd-0.11Zn-0.43Zr and Mg-2.70Nd-0.20Zn-0.41Zr alloys. The corrosion resistance of the alloys after double extrusion was also studied. The results show that the microstructure of the alloys under double extrusion becomes much finer and more homogeneous than those under once extrusion. The yield strength, ultimate tensile strength and elongation of the alloys under double extrusion are over 270 MPa, 300 MPa and 32%, respectively, indicating that outstanding mechanical properties of Mg-Nd-Zn-Zr alloy can be obtained by double extrusion. The results of immersion experiment and electrochemical measurements in SBF show that the corrosion resistance of Alloy 1 and Alloy 2 under double extrusion was increased by 7% and 8% respectively compared with those under just once extrusion.

  6. Corrosion resistance of Ti-6Al-4V and ASTM F75 alloys processed by electron beam melting

    Directory of Open Access Journals (Sweden)

    E. Almanza

    2017-07-01

    Full Text Available The electron beam melting (EBM is a useful technique for fabricating alloys that are difficult to machine and require expensive tools as well as the presence of inert atmosphere for further treatments. Under vacuum, EBM provides a controlled environment, reducing the drawbacks of the alloys of their processing in a conventional manner and thereby improving their microstructure, which can enhance corrosion resistance. In the present work, the corrosion resistance of the Ti-6Al-4V and ASTM F75 alloys was evaluated by using the Tafel extrapolation technique with scan rates of 0.05, 0.1 and 0.166 mV/s. The corrosion specimens were submerged in a Hank solution to simulate the corporal fluid. The specimens were characterized before and after the corrosion tests by optical microscopy and scanning electron microscopy, as well as a chemical microanalysis by EDS. The microstructural characterization before the corrosion tests revealed a dual phase (α + β microstructure and α′ martensite in the Ti-6Al-4V alloy. For the ASTM F75 (Co-base alloy, carbides were observed on the grain boundaries. Corrosion resistance increased in the Ti-6Al-4V alloy, from 0.50 to 0.14 mpy, possibly due to the formation of a TiO2 passive layer. For the case of the ASTM F75 alloy, the corrosion rate decreased from 0.21 to 0.14 milli-inches/year (mpy due to the formation of Cr layer. The corrosion results were observed to be very similar for the EBM fabricated alloys in comparison with more commercially fabricated alloys.

  7. Corrosion resistance and microstructure of alloy 625 weld overlay on ASTM A516 grade 70

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Mohammad J. [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Petroleum Engineering Dept.; Ketabchi, Mostafa [Amirkabir Univ. of Technology, Tehran (Iran, Islamic Republic of). Mining and Metallurgical Engineering Dept.

    2016-02-01

    Nickel-based alloys are a crucial class of materials because of their excellent corrosion resistance. In the present study, single layer and two layers alloy 625 weld overlays were deposited by GTAW process on A516 grade 70 carbon steel. The dilution in terms of Fe, Ni, Mo and Nb content was calculated in 30 points of weld overlay. Microstructure observations showed that alloy 625 had austenitic structure with two types of Laves and NbC secondary phases. The uniform and pitting corrosion resistance of alloy 625 weld overlay as casted and as forged were evaluated in accordance with ASTM G48-2011 standard at different temperatures to determine the weight loss and critical pitting temperature. For achieving a better comparison, samples from alloy 625 as casted and as forged were tested under the same conditions. The results point out that single layer alloy 625 weld overlay is not suitable for chloride containing environments, two layers alloy 625 weld overlay and alloy 625 as casted have acceptable corrosion resistance and almost the same critical pitting temperature. Alloy 625 as forged has the best corrosion resistance and the highest critical pitting temperature among all test specimens. Also, the corrosion behavior was evaluated in accordance with ASTM G28 standard. The corrosion rate of single layer weld overlay was unacceptable. The average corrosion rate of two layers weld overlay and in casted condition were 35.82 and 33.01 mpy, respectively. [German] Nickellegierungen sind aufgrund ihres exzellenten Korrosionswiderstandes eine bedeutende Werkstoffklasse. In der diesem Beitrag zugrunde liegenden Studie wurden mittels WIG-Schweissens ein- und zweilagige Schweissplattierungen auf den Kohlenstoffstahl A516 (Grade 70) aufgebracht. Die Vermischung in Form des Fe-, Ni-, Mo- und Nb-Gehaltes wurde an 30 Punkten der Schweissplattierungen berechnet. Die mikrostrukturellen Untersuchungen ergaben, dass die Legierung 625 eine austenitische Struktur mit zwei Arten von

  8. Corrosion Resistance of Electroless Ni-Cu-P Ternary Alloy Coatings in Acidic and Neutral Corrosive Mediums

    Directory of Open Access Journals (Sweden)

    Mbouillé Cissé

    2010-01-01

    Full Text Available Electroless Ni-Cu-P alloy coatings were deposited on the ordinary steel substrate in an acidic hypophosphite-type plating bath. These coatings were characterized by a scanning electron microscope (SEM and an X-ray diffraction. The micrograph shows that coating presents a nodular aspect and is relatively homogeneous and very smooth. The EDX analysis shows that the coating contains 12 wt.% of phosphorus element with a predominance of nickel element. In addition, the anticorrosion properties of the Ni-Cu-P coatings in 1 M HCl, 1 M H2SO4, and 3% NaCl solutions were investigated using Tafel polarization curves, electrochemical impedance spectroscopy, and SEM/EDX analysis. The result showed a marginal improvement in corrosion resistance in 3% NaCl solution compared to acidic medium. It also showed that the corrosion mechanism depends on the nature of the solution.

  9. Corrosion resistance of nickel and nickel alloys. (Latest citations from Information Services in Mechanical Engineering database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The bibliography contains citations concerning the corrosion resistance of nickel and nickel alloys used in electrical and structural materials and chemical processes. Topics include susceptibility of nickel to high temperature sulfidation, normal exposure to saline and other high chloride environments, pitting corrosion, and metal coatings. Special cases of corrosion of weld-filler metal combinations are also included. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  10. The role of solidification rate in the corrosion resistance of a directionally solidified novel aluminium-lanthanum alloy

    Energy Technology Data Exchange (ETDEWEB)

    Dzib-Perez, L. [Programa de Corrosion del Golfo de Mexico, Universidad Autonoma de Campeche, Av. Agustin Melgar s/n, Col. Buenavista, CP 24030 Campeche, Campeche (Mexico); Gonzalez-Sanchez, J. [Programa de Corrosion del Golfo de Mexico, Universidad Autonoma de Campeche, Av. Agustin Melgar s/n, Col. Buenavista, CP 24030 Campeche, Campeche (Mexico)]. E-mail: jagonzal@uacam.mx; Perez, T. [Programa de Corrosion del Golfo de Mexico, Universidad Autonoma de Campeche, Av. Agustin Melgar s/n, Col. Buenavista, CP 24030 Campeche, Campeche (Mexico); Bartolo-Perez, P. [Programa de Corrosion del Golfo de Mexico, Universidad Autonoma de Campeche, Av. Agustin Melgar s/n, Col. Buenavista, CP 24030 Campeche, Campeche (Mexico); CINVESTAV-Merida, Applied Physics Department, Carr. antigua a Progreso, km 6, CP 97310 Merida, Yucatan (Mexico); Juarez, A. [CIATEQ. Calzada del Retablo 150, CP 76150 Queretaro, Queretaro (Mexico)

    2006-08-15

    The corrosion resistance of a novel Al-12.6 wt.%La alloy manufactured using unidirectional solidification was studied by sensitive electrochemical techniques. It was found that the electrochemical behaviour of the alloy depends upon the formation of non-passive corrosion product layers. Different solidification rates produced dissimilar microstructures which promoted selective dissolution when the alloy was anodically polarized in distilled water. A model for the electrochemical behaviour of this alloy was proposed based on an equivalent circuit that simulated the impedance results.

  11. Preparation of Phytic Acid/Silane Hybrid Coating on Magnesium Alloy and Its Corrosion Resistance in Simulated Body Fluid

    Science.gov (United States)

    Wang, Fengwu; Cai, Shu; Shen, Sibo; Yu, Nian; Zhang, Feiyang; Ling, Rui; Li, Yue; Xu, Guohua

    2017-09-01

    In order to decrease the corrosion rate and improve the bioactivity of magnesium alloy, phytic acid/saline hybrid coatings were synthesized on AZ31 magnesium alloys by sol-gel dip-coating method. It was found that the mole ratio of phytic acid to γ-APS had a great influence on coating morphology and the corresponding corrosion resistance of the coated magnesium alloys. When the mole ratio of phytic acid to γ-APS was 1:1, the obtained hybrid coating was integral and without cracks, which was ascribed to the strong chelate capability of phytic acid and Si-O-Si network derived from silane. Electrochemical test result indicated that the corrosion resistance of the coated magnesium alloy was about 27 times larger than that of the naked counterpart. In parallel, immersion test showed that the phytic acid/silane hybrid coating could induce CaP-mineralized product deposition, which offered another protection for magnesium alloy.

  12. In Vivo Corrosion Resistance of Ca-P Coating on AZ60 Magnesium Alloy

    Institute of Scientific and Technical Information of China (English)

    Xing Xiao; Haiying Yu; Qingsan Zhu; Guangyu Li; Yang Qu; Rui Gu

    2013-01-01

    Magnesium-based alloys are frequently reported as potential biodegradable orthopedic implant materials.Controlling the degradation rate and mechanical integrity of magnesium alloys in the physiological environment is the key to their applications.In this study,calcium phosphate (Ca-P) coating was prepared on AZ60 magnesium alloy using phosphating technology.AZ60 samples were immersed in a phosphating solution at 37 ± 2 ℃ for 30 min,and the solution pH was adjusted to 2.6 to 2.8 by adding NaOH solution.Then,the samples were dried in an attemperator at 60 ℃.The degradation behavior was studied in vivo using Ca-P coated and uncoated magnesium alloys.Samples of these two different materials were implanted into rabbit femora,and the corrosion resistances were evaluated after 1,2,and 3 months.The Ca-P coated samples corroded slower than the uncoated samples with prolonged time.Significant differences (p < 0.05) in mass losses and corrosion rates between uncoated samples and Ca-P coated samples were observed by micro-computed tomography.The results indicate that the Ca-P coating could slow down the degradation of magnesium alloy in vivo.

  13. High corrosion resistance of austenitic stainless steel alloyed with nitrogen in an acid solution

    Energy Technology Data Exchange (ETDEWEB)

    Metikos-Hukovic, M., E-mail: mmetik@fkit.h [Department of Electrochemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Savska 16, P.O. Box 177, 100000 Zagreb (Croatia); Babic, R. [Department of Electrochemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Savska 16, P.O. Box 177, 100000 Zagreb (Croatia); Grubac, Z. [Department of General and Inorganic Chemistry, Faculty of Chemistry and Technology, University of Split, 21000 Split (Croatia); Petrovic, Z. [Department of Electrochemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Savska 16, P.O. Box 177, 100000 Zagreb (Croatia); Lajci, N. [Faculty of Mine and Metallurgy, University of Prishtina, 10000 Prishtina, Kosovo (Country Unknown)

    2011-06-15

    Highlights: {yields} ASS alloyed with nitrogen treated at 1150 {sup o}C exhibits microstructure homogeneity. {yields} Passivation peak of ASS corresponds to oxidation of metal and absorbed hydrogen. {yields} Transfer phenomena and conductivity depend on the film formation potential. {yields} Electronic structure of the passive film and its corrosion resistance correlate well. {yields} Passive film on ASS with nitrogen is low disordered and high corrosion resistant. - Abstract: Passivity of austenitic stainless steel containing nitrogen (ASS N25) was investigated in comparison with AISI 316L in deareated acid solution, pH 0.4. A peculiar nature of the passivation peak in a potentiodynamic curve and the kinetic parameters of formation and growth of the oxide film have been discussed. The electronic-semiconducting properties of the passive films have been correlated with their corrosion resistance. Alloying austenitic stainless steel with nitrogen increases its microstructure homogeneity and decreases the concentration of charge carriers, which beneficially affects the protecting and electronic properties of the passive oxide film.

  14. [The effect on anti-acid corrosion resistance of Ni-Cr alloy coating titanium].

    Science.gov (United States)

    Hu, Bin; Zhang, Fu-qiang

    2003-04-01

    The aim of this study was to investigate the variation of the corrosion resistance of Ni-Cr alloy in acid environment before and after coating titanium in vitro. 1. Surface treatment using sol-gel technique of coating titanium. The steps were as follows: (1) Pre-treatment: sanding, washing and activation in order to remove the oxidative product; (2) The preparation of sol: some small charged particles produced by the hydrolytic reaction, and formed sol. These particles would congeal into extremely small ones (diameter usually is 5 microns); (3) Coating; (4) Heat treatment: The organism was resolved and volatilizeed at high temperature, and the atoms of Ti were left. These atoms of Ti were very active and could combine firmly with the atoms on the surface awaiting of treatment. 2. artificial saliva; pH = 7.0 and pH = 5.6; temperature: 36.5 degrees C 3. Electrochemical test: polarization curve; instrument: ZF-3 poteniostat. Before coating titanium, when pH was 7.0, the electrode potential of Ni-Cr alloy was -160 mV, and the self-corrosion current density was 0.262 microA cm-2; when pH = 5.6, the data were -182 mV and 0.352 microA cm-2, respectively. This result showed that when pH value reduced, the potential and current density descended, too. This indicated that the material was easy to be corroded. After coating titanium, when pH value was 7.0, the potential was -71 mV, the self-corrosion current density was 0.152 microA cm-2; when pH = 5.6, the data were -89 mV and 0.174 microA cm-2. This indicated that the corrosion rate of material descended evidently after coating titanium in acid environment. (1) Not only before coating Ti but also after coating, the corrosion resistance of Ni-Cr alloy would descend in acid environment;(2) In acid environment, the corrosion resistance of Ni-Cr alloy after coating titanium was superior to that of the material before coating. So was in neutral environment.

  15. Corrosion-resistant metallic coatings

    OpenAIRE

    F. Presuel-Moreno; M.A. Jakab; N. Tailleart; Goldman, M.; J. R. Scully

    2008-01-01

    We describe recent computational and experimental studies on the corrosion properties of metallic coatings that can be tailored (tuned) to deliver up to three corrosion-inhibiting functions to an underlying substrate. Attributes are tuned by a selection of alloy compositions and nanostructures, ideally in alloy systems that offer flexibility of choice to optimize the corrosion-resisting properties. An amorphous Al-based coating is tuned for corrosion protection by on-demand release of ionic i...

  16. Electroless Plating of Ni-Fe-P Alloy and Corrosion Resistance of the Deposit

    Institute of Scientific and Technical Information of China (English)

    Senlin WANG

    2005-01-01

    Electroless Ni-Fe-P alloys in an alkaline bath were plated. Theeffects of deposition parameters on the plating rate and the coating composition were examined. The weight loss test and the anodic polarization measurement of the deposits in 3.5 wt pct NaCl solution (pH7.0) showed that the deposits with the mole ratio of NiSO4/FeSO4 being 0.07:0.03, pH8.0 and 7.5 possess better corrosion resistance than that of the other deposits and the Ni-Fe-P deposits did not form passive films in this environment. In 5.0 wt pct NaOH solution, the Ni-Fe-P deposits have better corrosion resistance and formed passive films.

  17. Influence of composition and heat treatments on corrosion resistance of Fe-Co-BSi amorphous alloys

    Energy Technology Data Exchange (ETDEWEB)

    Angelini, E.; Antonione, C.; Baricco, M.; Rosalbino, F.; Zucchi, F. (Ist. Elettrotecnico Nazionale Galileo Ferraris, Turin (Italy) Turin Univ. (Italy) Politecnico di Torino (Italy))

    This paper studies the influence of composition and heat treatments on the corrosion resistance, in a solution of Na/sub 2/SO/sub 4/ 0.05M + H/sub 2/SO/sub 4/ 0.05M, at 1.5 pH, of a series of iron base amorphous alloys with increasing cobalt content, i.e., Fe/sub 80-x/Co/sub x/B/sub 10/Si/sub 10/ with x=0, 30, and 80. The treatments were carried out in an argon atmosphere over increasing time durations: 30, 60, 120, and 240 minutes, and increasing temperatures: 350, 400, 450 and 500 degrees C respectively. It was possible to observe that, independent of heat treatment, the corrosion resistance increased with increasing cobalt concentration. In comparing samples having the same chemical composition, it was noted that their electrochemical behaviour worsened with increasing temperature and time.

  18. Improved stress corrosion cracking resistance of a novel biodegradable EW62 magnesium alloy by rapid solidification, in simulated electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Hakimi, O.; Aghion, E. [Department of Materials Engineering, Ben-Gurion University of the Negev, P.O. Box 653, Beer-Sheva 84105 (Israel); Goldman, J., E-mail: jgoldman@mtu.edu [Biomedical Engineering Department, Michigan Technological University, Houghton, MI, 49931 (United States)

    2015-06-01

    The high corrosion rate of magnesium (Mg) and Mg-alloys precludes their widespread acceptance as implantable biomaterials. Here, we investigated the potential for rapid solidification (RS) to increase the stress corrosion cracking (SCC) resistance of a novel Mg alloy, Mg–6%Nd–2%Y–0.5%Zr (EW62), in comparison to its conventionally cast (CC) counterpart. RS ribbons were extrusion consolidated in order to generate bioimplant-relevant geometries for testing and practical use. Microstructural characteristics were examined by SEM. Corrosion rates were calculated based upon hydrogen evolution during immersion testing. The surface layer of the tested alloys was analyzed by X-ray photoelectron spectroscopy (XPS). Stress corrosion resistance was assessed by slow strain rate testing and fractography. The results indicate that the corrosion resistance of the RS alloy is significantly improved relative to the CC alloy due to a supersaturated Nd enrichment that increases the Nd{sub 2}O{sub 3} content in the external oxide layer, as well as a more homogeneous structure and reduced grain size. These improvements contributed to the reduced formation of hydrogen gas and hydrogen embrittlement, which reduced the SCC sensitivity relative to the CC alloy. Therefore, EW62 in the form of a rapidly solidified extruded structure may serve as a biodegradable implant for biomedical applications. - Highlights: • Here we have evaluated the corrosion resistance of a novel Mg alloy (EW62). • Rapid solidification reduces the hydrogen gas evolution and hydrogen embrittlement. • Rapid solidification increases the stress corrosion cracking resistance of EW62. • Improvement is due to enrichment with supersaturated Nd in the external oxide film. • Rapidly solidified and extruded EW62 may serve as a biodegradable medical implant.

  19. Evaluation of the stress corrosion cracking resistance of several high strength low alloy steels

    Science.gov (United States)

    Humphries, T. S.; Nelson, E. E.

    1980-01-01

    The stress corrosion cracking resistance was studied for high strength alloy steels 4130, 4340, for H-11 at selected strength levels, and for D6AC and HY140 at a single strength. Round tensile and C-ring type specimens were stressed up to 100 percent of their yield strengths and exposed to alternate immersion in salt water, salt spray, the atmosphere at Marshall Space Flight Center, and the seacoast at Kennedy Space Center. Under the test conditions, 4130 and 4340 steels heat treated to a tensile strength of 1240 MPa (180 ksi), H-11 and D6AC heat treated to a tensile strength of 1450 MPa (210 ksi), and HY140 (1020 MPa, 148 ksi) are resistant to stress corrosion cracking because failures were not encountered at stress levels up to 75 percent of their yield strengths. A maximum exposure period of one month for alternate immersion in salt water or salt spray and three months for seacoast is indicated for alloy steel to avoid false indications of stress corrosion cracking because of failure resulting from severe pitting.

  20. Electrolessly Plated Ni-Zn(Fe)-P Alloy and Its Corrosion Resistance Properties

    Institute of Scientific and Technical Information of China (English)

    WANG Sen-lin; WU Hui-huang

    2005-01-01

    The autocatalytic deposition of Ni-Zn(Fe)-P alloys has been carried out on substrate of carbon steel from a bath containing nickel sulfate, zinc sulfate, sodium hypophosphite, sodium citrate and boric acid. The effects of pH and the molar ratio of NiSO4/ZnSO4 on the deposition rate and the composition of deposits have been studied. It was found that the presence of zinc sulfate in the bath has an inhibitory effect on the alloy deposition. The structure and the surface morphology of Ni-Zn(Fe)-P coatings were characterized with XRD and SEM, respectively. The alloys plated under the experimental conditions consisted of an amorphous phase coexisting with a crystalline cubic Ni phase(poly-crystalline). The surface morphology of the coating is dependent on the deposition parameters. The corrosion resistance of the Ni-Zn(Fe)-P deposits was examined via mass loss tests and anodic polarization measurements, respectively. The results show that the surface morphologies of the deposits and the corrosion resistance of the deposits have been improved. The results of mass loss tests almost accord with those of anodic polarization measurements. The corrosion mechanisms of Ni-Zn(Fe)-P alloys in NaCl and NaOH solutions were investigated by means of EDX. The deposit immersed in an NaCl or an NaOH solution contains more content of oxygen and less contents of the metals(except Fe) than that placed in air, which shows that the NaCl or NaOH solution can accelerate the oxidation of the deposit.

  1. Corrosion resistance of FeAl intermetallic phase based alloy in water solution of NaCl

    Directory of Open Access Journals (Sweden)

    J. Cebulski

    2008-03-01

    Full Text Available Purpose: Recognizing of corrosion mechanisms in liquid mediums can lead to obtain corrosion-proof material e.g. by applying passivation phenomenon. In this paper attention was paid to determine the corrosion resistance of Fe40Al intermetallic phase based alloy in corrosive medium of liquid NaCl. Research of material susceptibility to surface activation in the pipeline of corrosion processes are conducted.Design/methodology/approach: In the corrosion research electrolyser, potentiostat „Solartron 1285” and computer with „CorrWare 2” software were used. Results of the research were worked out with „CorrView” software. The potentials values were determined in relation to normal hydrogen electrode (NEW. The recording of potential/density of current - time curve was conducted for 300 s. Polarization of samples were conducted in range of potential from 300 mV lower than stationary to Ecor + 1500 mV. Potential change rate amounted 10 mV/min every time.Findings: The results of research conducted in 3% NaCl solution, the best electrochemical corrosion resistance were showed by samples after annealing during 72 hours. It was confirmed by the lowest value of corrosion current density, low value of passive current density, pitting corrosion resistance much higher than in other samples.Practical implications: The last feature is the reason to conduct the research for this group of materials as corrosion resistance materials. Especially FeAl intermetallic phase based alloys are objects of research in Poland and all world during last years.Originality/value: The goal of this work was to determine the influence of passivation in water solutions of H2SO4 and HNO3 on corrosion resistance of Fe40Al intermetallic phase based alloy in 3% NaCl solutions.

  2. Corrosion resistance and durability of siloxane ceramic/polymer films for aluminum alloys in marine environments

    Science.gov (United States)

    Kusada, Kentaro

    The objective of this study is to evaluate corrosion resistance and durability of siloxane ceramic/polymer films for aluminum alloys in marine environments. Al5052-H3 and Al6061-T6 were selected as substrates, and HCLCoat11 and HCLCoat13 developed in the Hawaii Corrosion Laboratory were selected for the siloxane ceramic/polymer coatings. The HCLCoat11 is a quasi-ceramic coating that has little to no hydrocarbons in its structure. The HCLCoat13 is formulated to incorporate more hydrocarbons to improve adhesion to substrate surfaces with less active functionalities. In this study, two major corrosion evaluation methods were used, which were the polarization test and the immersion test. The polarization tests provided theoretical corrosion rates (mg/dm 2/day) of bare, HCLCoat11-coated, and HCLCoat13-coated aluminum alloys in aerated 3.15wt% sodium chloride solution. From these results, the HCLCoat13-coated Al5052-H3 was found to have the lowest corrosion rate which was 0.073mdd. The next lowest corrosion rate was 0.166mdd of the HCLCoat11-coated Al5052-H3. Corrosion initiation was found to occur at preexisting breaches (pores) in the films by optical microscopy and SEM analysis. The HCLCoat11 film had many preexisting breaches of 1-2microm in diameter, while the HCLCoat13 film had much fewer preexisting breaches of less than 1microm in diameter. However, the immersion tests showed that the seawater immersion made HCLCoat13 film break away while the HCLCoat11 film did not apparently degrade, indicating that the HCLCoat11 film is more durable against seawater than the HCLCoat13. Raman spectroscopy revealed that there was some degradation of HCLCoat11 and HCLCoat13. For the HCLCoat11 film, the structure relaxation of Si-O-Si linkages was observed. On the other hand, seawater generated C-H-S bonds in the HCLCoat13 film resulting in the degradation of the film. In addition, it was found that the HCLCoat11 coating had anti-fouling properties due to its high water contact

  3. Effect of samarium on microstructure and corrosion resistance of aged as-cast AZ92 magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    吴道高; 颜世宏; 王志强; 张志琦; 苗睿瑛; 张小伟; 陈德宏

    2014-01-01

    The effects of samarium (Sm) on microstructure and corrosion resistance of AZ92 magnesium alloy were characterized and analyzed by scanning electronic microscopy, X-ray diffraction, mass loss test, electrochemical impedance spectroscopy, X-ray photoelectron spectroscopy and potentio-dynamic polarization test. The results showed that the added Sm could promote continuous precipitation ofβ-Mg17Al12 phase in grains, and meanwhile restrain discontinuous precipitation of the same phase along the grain boundaries. Thus, the precipitations distributed more uniformly in the aged AZ92 magnesium alloys. When the content of Sm was 0.5 wt.%, the corrosion resistance of aged AZ92 alloy tended to be the best, which was due to theβ-phase distributes more homogeneous reducing the galvanic corrosion. The corrosion product film had more integrality and compactness than AZ92 alloys without Sm. However, it resulted in worse corrosion resistance of AZ92 alloy because of the formation of mass cathodic Al2Sm phase coming from excess Sm in AZ92 alloy.

  4. Improved stress corrosion cracking resistance of a novel biodegradable EW62 magnesium alloy by rapid solidification, in simulated electrolytes.

    Science.gov (United States)

    Hakimi, O; Aghion, E; Goldman, J

    2015-06-01

    The high corrosion rate of magnesium (Mg) and Mg-alloys precludes their widespread acceptance as implantable biomaterials. Here, we investigated the potential for rapid solidification (RS) to increase the stress corrosion cracking (SCC) resistance of a novel Mg alloy, Mg-6%Nd-2%Y-0.5%Zr (EW62), in comparison to its conventionally cast (CC) counterpart. RS ribbons were extrusion consolidated in order to generate bioimplant-relevant geometries for testing and practical use. Microstructural characteristics were examined by SEM. Corrosion rates were calculated based upon hydrogen evolution during immersion testing. The surface layer of the tested alloys was analyzed by X-ray photoelectron spectroscopy (XPS). Stress corrosion resistance was assessed by slow strain rate testing and fractography. The results indicate that the corrosion resistance of the RS alloy is significantly improved relative to the CC alloy due to a supersaturated Nd enrichment that increases the Nd2O3 content in the external oxide layer, as well as a more homogeneous structure and reduced grain size. These improvements contributed to the reduced formation of hydrogen gas and hydrogen embrittlement, which reduced the SCC sensitivity relative to the CC alloy. Therefore, EW62 in the form of a rapidly solidified extruded structure may serve as a biodegradable implant for biomedical applications.

  5. Fabrication of biomimetic hydrophobic films with corrosion resistance on magnesium alloy by immersion process

    Energy Technology Data Exchange (ETDEWEB)

    Liu Yan, E-mail: liuyan2000@jlu.edu.cn [Key Laboratory for Bionic Engineering (Ministry of Education), Jilin University, Changchun 130022 (China); Lu Guolong; Liu Jindan; Han Zhiwu; Liu Zhenning [Key Laboratory for Bionic Engineering (Ministry of Education), Jilin University, Changchun 130022 (China)

    2013-01-01

    Highlights: Black-Right-Pointing-Pointer We have developed a facile and simple method of creating a hydrophobic surface on a magnesium alloy by an immersion process at room temperature. Black-Right-Pointing-Pointer The distribution of the micro-structure and the roughness of the surface play critical roles in transforming from hydrophilic to hydrophobic. Black-Right-Pointing-Pointer The hydrophobic coatings possess better corrosion resistance than magnesium alloy matrix. - Abstract: Biomimetic hydrophobic films of crystalline CeO{sub 2} were prepared on magnesium alloy by an immersion process with cerium nitrate solution and then modified with DTS (CH{sub 3}(CH{sub 2}){sub 11}Si(OCH{sub 3}){sub 3}). The CeO{sub 2} films fabricated with 20-min immersion yield a water contact angle of 137.5 {+-} 2 Degree-Sign , while 20-min DTS treatment on top of CeO{sub 2} can further enhance the water contact angle to 146.7 {+-} 2 Degree-Sign . Then corrosion-resistant property of these prepared films against NaCl solution was investigated and elucidated using electrochemical measurements.

  6. Corrosion resistance of porous NiTi biomedical alloy in simulated body fluids

    Science.gov (United States)

    Stergioudi, F.; Vogiatzis, C. A.; Pavlidou, E.; Skolianos, S.; Michailidis, N.

    2016-09-01

    The corrosion performance of two porous NiTi in physiological and Hank’s solutions was investigated by potentiodynamic polarization, cyclic polarization and impedance spectroscopy. Electric models simulating the corrosion mechanism at early stages of immersion were proposed, accounting for both microstructural observations and electrochemical results. Results indicate that both porous samples were susceptible to localized corrosion. The porosity increase (from 7% to 18%) resulted in larger and wider pore openings, thus favoring the corrosion resistance of 18% porous NiTi. Strengthening of corrosion resistance was observed in Hank’s solution. The pore morphology and micro-galvanic corrosion phenomena were determining factors affecting the corrosion resistance.

  7. INFLUENCE OF PHOSPHATIZED SURFACE LAYER ON CORROSION RESISTANCE OF Mg-Al-RE ALLOY

    OpenAIRE

    Katarína Miková; Filip Pastorek; Libor Trško; Sylvia Dundeková

    2015-01-01

    This contribution deals with evaluation of the corrosion resistance of extruded Mg-2Al-1RE (AE21) magnesium alloy in the state before and after treatment of ground surface by selected phosphatizing procedure. Specimens were exposed to 0.1M NaCl solution for several time periods starting from 5 minutes up-to 168 hours at room temperature of 22 ± 1 °C. Afterwards electrochemical impedance spectroscopy was carried out on the exposed specimens. Based on the results obtained from the electroc...

  8. Effect of equal-channel angular pressing on pitting corrosion resistance of anodized aluminum-copper alloy

    Institute of Scientific and Technical Information of China (English)

    In-Joon SON; Hiroaki NAKANO; Satoshi OUE; Shigeo KOBAYASHI; Hisaaki FUKUSHIMA; Zenji HORITA

    2009-01-01

    The effect of equal-channel angular pressing(ECAP) on the pitting corrosion resistance of anodized Al-Cu alloy was investigated by electrochemical techniques in a solution containing 0.2 mol/L AlCl3 and also by surface analysis. Anodizing was conducted for 20 min at 200 and 400 A/m2 in a solution containing 1.53 mol/L H2SO4 and 0.018 5 mol/L Al2(SO4)3-16H2O at 20 ℃. Anodized Al-Cu alloy was immediately dipped in boiling water for 20 min to seal the micro pores present in anodic oxide films. The time required before initiating pitting corrosion of anodized Al-Cu alloy is longer with ECAP than without, indicating that ECAP process improves the pitting corrosion resistance of anodized Al-Cu alloy. Second phase precipitates such as Si, Al-Cu-Mg and Al-Cu-Si-Fe-Mn intermetallic compounds are present in Al-Cu alloy and the size of these precipitates is greatly decreased by application of ECAP. Al-Cu-Mg intermetallic compounds are dissolved during anodization, whereas the precipitates composed of Si and Al-Cu-Si-Fe-Mn remain in anodic oxide films due to their more noble corrosion potential than Al. FE-SEM and EPMA observation reveal that the pitting corrosion of anodized Al-Cu alloy occurs preferentially around Al-Cu-Si-Fe-Mn intermetallic compounds, since the anodic oxide films are absent at the boundary between the normal oxide films and these impurity precipitates. The improvement of pitting corrosion resistance of anodized Al-Cu alloy processed by ECAP appears to be attributed to a decrease in the size of precipitates, which act as origins of pitting corrosion.

  9. Evaluation of Corrosion Resistance of Titanium Alloys Used for Medical Implants

    Directory of Open Access Journals (Sweden)

    Szewczenko J.

    2016-06-01

    Full Text Available The study presents the results of investigations of modeling the usable properties of implant surfaces made of Ti6Al7Nb alloy, using the example of a dynamic hip screw (DHS applied in surgical treatment of intertrochanteric femoral neck fractures. Numerical simulation has been performed for the model load of femoral fixation with DHS screw. The load simulation results provided the basis to select mechanical properties of the fixator elements and to define those fixation areas which are mostly susceptible to development of corrosion. The surfaces of Ti6Al7Nb alloy were ground, vibro-abrasive machined, mechanically polished, sandblasted, anode oxidized at different voltage values and steam sterilized. Results of surface topography evaluation, resistance to pitting and crevice corrosion as well as degradation kinetics of the outer layer were presented. Usability of the formed passive layer in clinical applications was evaluated through wear and corrosion tests of the femoral fixation model. The test results proved usefulness of the proposed surface modification methods for clinical application of different size and shape implants

  10. Corrosion resistance of Ni–Co alloy and Ni–Co/SiC nanocomposite coatings electrodeposited by sediment codeposition technique

    Energy Technology Data Exchange (ETDEWEB)

    Bakhit, Babak, E-mail: b_bakhit@sut.ac.ir [Surface Engineering Group, Advanced Materials Research Center, Faculty of Materials Engineering, Sahand University of Technology, PO Box 51335-1996, Tabriz (Iran, Islamic Republic of); Akbari, Alireza; Nasirpouri, Farzad [Surface Engineering Group, Advanced Materials Research Center, Faculty of Materials Engineering, Sahand University of Technology, PO Box 51335-1996, Tabriz (Iran, Islamic Republic of); Hosseini, Mir Ghasem [Electrochemistry Research Laboratory, Department of Physical Chemistry, Chemistry Faculty, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2014-07-01

    Corrosion resistance of Ni–Co alloy and Ni–Co/SiC nanocomposite coatings electrodeposited in a modified Watts bath using sediment codeposition (SCD) technique was evaluated by potentiodynamic polarization measurements in the 3.5% NaCl solution and studied as a function of deposition conditions In order to characterize the morphology, chemical and phase compositions of the coatings, scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDS) and X-ray diffraction (XRD) were utilized, respectively. It was observed that the cobalt content in the Ni–Co alloy coatings was increased through an anomalous behavior by increasing the cobalt concentration in the electrolyte. The highest percentage of SiC nano-particles (8.1 vol.%) in the Ni–Co/SiC nanocomposite coatings was achieved at 3 A/dm{sup 2} deposition current density and 5 g/l particle concentration. SEM and EDS analysis illustrated that SiC nano-particles were distributed uniformly throughout the nanocomposite coatings. The potentiodynamic polarization tests indicated that the corrosion resistance of the Ni–Co alloy coatings was varied as a function of the cobalt content, and the corrosion resistance of the Ni–Co/SiC nanocomposite coatings was markedly higher than the corrosion resistance of the Ni–Co alloy coatings. Among the studied coatings, Ni–Co/SiC nanocomposite coatings containing 8.1 vol.% SiC nano-particles exhibited the best corrosion resistance.

  11. Microstructures, mechanical properties and corrosion resistance of the Zr−xTi (Ag) alloys for dental implant application

    Energy Technology Data Exchange (ETDEWEB)

    Cui, W.F., E-mail: cuiwf@atm.neu.edu.cn; Liu, N.; Qin, G.W.

    2016-06-15

    The Zr−xTi (Ag) alloys were designed for the application of dental implants. The microstructures of Zr−20Ti and Zr−40Ti alloy were observed using optical microscope and transmission electronic microscope. The hardness and compressive tests were performed to evaluate the mechanical properties of the Zr−xTi alloys. The electrochemical behavior of the Zr−xTi alloys with and without 6% Ag was investigated in the acidified artificial saliva containing 0.1% NaF (pH = 4). For comparison, the electrochemical behavior of cp Ti was examined in the same condition. The results show that the quenched Zr−20Ti and Zr−40Ti alloy exhibit acicular martensite microstructures containing twin substructure. They display good mechanical properties with the hardness of ∼330HV, the yield strength of ∼1000 MPa and the strain to fracture of ∼25% at room temperature. Adding 6% Ag to Zr−20Ti alloy enhances the passivity breakdown potential and the self-corrosion potential, but hardly affects the corrosion current density and the impedance modulus. 6% Ag in Zr−40Ti alloy distinctly increases pitting corrosion resistance, which is attributed the formation of thick, dense and stable passive film under the joint action of titanium and silver. In comparison with cp Ti, Zr−40Ti−6Ag alloy possesses the same good corrosion resistance in the rigorous oral environment as well as the superior mechanical properties. - Highlights: • The quenched Zr20Ti and Zr40Ti obtain acicular martensite microstructure. • Zr20Ti and Zr40Ti possess high hardness, strength and strain to fracture. • Increasing Ti content decreases corrosion current density. • Adding Ag enhances passivation breakdown potentials of Zr20Ti and Zr40Ti. • Zr40Ti6Ag has optimum mechanical properties and pitting corrosion resistance.

  12. Effect of long-period stacking ordered phase on microstructure, mechanical property and corrosion resistance of Mg alloys: A review

    Directory of Open Access Journals (Sweden)

    Daokui Xu

    2016-04-01

    Full Text Available Magnesium alloys containing long period stacking ordered (LPSO phase have been received a great deal of attention in the last decade owing to their excellent comprehensive properties of mechanical strength and corrosion resistance. In this paper, some fundamental aspects of LPSO containing Mg alloys have been reviewed, including: (1 microstructural characterization, formation conditions and the associated phase transformation of LPSO phases in Mg alloys; (2 deformation mechanism of LPSO phases and their influence on the deformation mechanism of the Mg matrix; (3 effect of LPSO structure on the mechanical performance such as tensile strength, creep resistance, fracture toughness and fatigue strength; (4 corrosion behavior of LPSO containing Mg alloys and their possible applications as the biomaterials. Moreover, some remaining unsolved issues of the LPSO containing Mg alloys and the future target about how to further improve their service properties have been also described.

  13. Enhanced corrosion resistance and biocompatibility of β-type Ti–25Nb–25Zr alloy by electrochemical anodization

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Her-Hsiung [Department of Dentistry, National Yang-Ming University, Taipei, 112 Taiwan (China); Graduate Institute of Basic Medical Science, China Medical University, Taichung, 404 Taiwan (China); Department of Biomedical Informatics, Asia University, Taichung, 413 Taiwan (China); Department of Stomatology, Taipei Veterans General Hospital, Taipei, 112 Taiwan (China); Wu, Chia-Ping; Sun, Ying-Sui; Huang, Hsun-Miao [Institute of Oral Biology, National Yang-Ming University, Taipei, 112 Taiwan (China); Lee, Tzu-Hsin, E-mail: biomaterials@hotmail.com [School of Dentistry, Chung Shan Medical University, Taichung, 402 Taiwan (China); Oral Medicine Center, Chung Shan Medical University Hospital, Taichung, 402 Taiwan (China)

    2013-12-31

    The biocompatibility of implants is largely determined by their surface characteristics. This study presents a novel method for performing electrochemical anodization on β-type Ti–25Nb–25Zr alloy with a low elastic modulus (approximately 70 GPa). This method results in a thin hybrid layer capable of enhancing the surface characteristics of the implants. We investigated the surface topography and microstructure of the resulting Ti–25Nb–25Zr alloy. The corrosion resistance was evaluated using potentiodynamic polarization curve measurements in simulated body fluid. The cytotoxicity was evaluated according to International Organization for Standardization 10993–5 specification. Cell adhesion of human bone marrow mesenchymal stem cells on the test specimens was observed using scanning electron microscopy and fluorescence microscopy. The anodization produced a thin (approximately 40 nm-thick) hybrid oxide layer with a nanoporous outer sublayer (pore size < 15 nm) and a dense inner layer. The thin hybrid oxide layer increased the corrosion resistance of the Ti–25Nb–25Zr alloy by increasing the corrosion potential and decreasing both the corrosion rate and passive current. Ti–25Nb–25Zr alloys with and without anodization treatment were non-toxic. Surface nanotopography on the anodized Ti–25Nb–25Zr alloy enhanced protein adsorption and cell adhesion. Our results demonstrate that electrochemical anodization increases the corrosion resistance and cell adhesion of β-type Ti–25Nb–25Zr alloy while providing a lower elastic modulus suitable for implant applications. - Highlights: • An electrochemical anodization was applied to β-type Ti–25Nb–25Zr alloy surface. • Anodized surface had nanoscale hybrid oxide layer. • Anodized surface increased corrosion resistance due to dense inner sublayer. • Anodized surface enhanced cell adhesion due to nanoporous outer sublayer. • Electrochemical anodization has potential as implant surface treatment.

  14. Effect of carbon on corrosion resistance of powder-processed Fe–0.35%P alloys

    Indian Academy of Sciences (India)

    Yashwant Mehta; Shefali Trivedi; K Chandra; P S Mishra

    2010-08-01

    The corrosion behaviour of phosphoric irons containing 0.35 wt % P, 2% copper, 2% nickel, 1% silicon, 0.5% molybdenum, with/without 0.15% carbon prepared by powder forging route were studied in different environments. The various environments chosen were acidic (0.25 M H2SO4 solution of pH 0.6), neutral/marine (3.5% NaCl solution of pH 6.8) and alkaline (0.5 M Na2CO3 + 1.0 M NaHCO3 solution of pH 9.4). The corrosion studies were conducted using Tafel extrapolation and linear polarization methods. The studies also compare Armco iron with phosphoric irons. It was observed that the addition of carbon improved the corrosion resistance of a Fe–0.35%P–2%Ni–2%Cu–1%Si–0.5%Mo alloy in all the environments. Corrosion rates were highest in acid medium, minimal in alkaline medium and low in neutral solution. SEM/EDAX was used to characterize the compositions.

  15. Enhancing surface integrity and corrosion resistance of laser cladded Cr-Ni alloys by hard turning and low plasticity burnishing

    Science.gov (United States)

    Zhang, Peirong; Liu, Zhanqiang

    2017-07-01

    In this research, the enhancements of surface integrity and corrosion resistance of the laser cladded parts by combined hard turning with low plasticity burnishing (LPB) were presented by both potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) methods. The investigated results indicated that the corrosion resistance of the laser cladded parts could be improved by combined hard turning with LPB than by sole hard turning. An innovative model was proposed to explain the corrosion mechanism of the laser cladded parts after hybrid machining. Both surface adsorption and passive film were observed to dominate the corrosion resistance of the hybrid machined Cr-Ni alloys by laser cladding. The surface integrity led to the inhomogeneity of passive film, and then altered the corrosion resistance of the machined samples. In terms of the surface integrity factors, residual compressive stresses and surface finish were found to play more important roles in improving the corrosion resistance than the grain refinement and microhardness of the machined surface layer materials did. Based on the research results, anti-corrosion parts with laser cladded alloys could be fabricated by hybrid machining using the combination of hard turning and LPB.

  16. Improving the corrosion wear resistance of AISI 316L stainless steel by particulate reinforced Ni matrix composite alloying layer

    Energy Technology Data Exchange (ETDEWEB)

    Xu Jiang; Zhuo Chengzhi; Tao Jie; Liu Linlin [Department of Material Science and Engineering, Nanjing University of Aeronautics and Astronautics, 29 Yudao Street, Nanjing 210016 (China); Jiang Shuyun [Department of Mechanical Engineering, Southeast University, 2 Sipailou, Nanjing 210096 (China)], E-mail: xujiang73@nuaa.edu.cn

    2009-01-07

    In order to overcome the problem of corrosion wear of AISI 316L stainless steel (SS), two kinds of composite alloying layers were prepared by a duplex treatment, consisting of Ni/nano-SiC and Ni/nano-SiO{sub 2} predeposited by brush plating, respectively, and subsequent surface alloying with Ni-Cr-Mo-Cu by a double glow process. The microstructure of the two kinds of nanoparticle reinforced Ni-based composite alloying layers was investigated by means of SEM and TEM. The electrochemical corrosion behaviour of composite alloying layers compared with the Ni-based alloying layer and 316L SS under different conditions was characterized by potentiodynamic polarization test and electrochemical impedance spectroscopy. Results showed that under alloying temperature (1000 deg. C) conditions, amorphous nano-SiO{sub 2} particles still retained the amorphous structure, whereas nano-SiC particles were decomposed and Ni, Cr reacted with SiC to form Cr{sub 6.5}Ni{sub 2.5}Si and Cr{sub 23}C{sub 6}. In static acidic solution, the corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiO{sub 2} particles interlayer is lower than that of the Ni-based alloying layer. However, the corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiO{sub 2} particles interlayer is prominently superior to that of the Ni-based alloying layer under acidic flow medium condition and acidic slurry flow condition. The corrosion resistance of the composite alloying layer with the brush plating Ni/nano-SiC particles interlayer is evidently lower than that of the Ni-based alloying layer, but higher than that of 316L SS under all test conditions. The results show that the highly dispersive nano-SiO{sub 2} particles are helpful in improving the corrosion wear resistance of the Ni-based alloying layer, whereas carbides and silicide phase are deleterious to that of the Ni-based alloying layer due to the fact that the preferential removal of the matrix

  17. Effect of Nitrogen Ion Implantation on the Structure and Corrosion Resistance of Equiatomic NiTi Shape Memory Alloy

    Institute of Scientific and Technical Information of China (English)

    HUA Yingjie; WANG Chongtai; MENG Changgong; YANG Dazhi

    2006-01-01

    To protect the surface of NiTi from corrosion, an ion implantation method was proposed. In the present work, a surface oxidized sample was implanted with nitrogen at energy of 100 keV. The corrosion resistance property was examined by the anodic polarization method in a simulated body fluid (SBF) at a temperature of 37 ℃ and contrasted to non-implanted NiTi samples. The composition and structure of the implanted layers were investigated by XPS. The experimental results from the electrochemical measurements provide an evidence that the nitrogen ion-implantation increases the corrosion resistance of NiTi shape memory alloy.

  18. Fabrication and corrosion resistance of Mg-Zn-Y-based nano-quasicrystals alloys

    Directory of Open Access Journals (Sweden)

    Zhifeng Wang

    2012-02-01

    Full Text Available A wedge-shaped copper mold was used to fabricate micro quasicrystals(QCs. Stable Mg-Zn-Y-based nano-QCs were directly synthesized through this simple route instead of crystallization from metallic glasses or complicated forming processes at high temperature. The study showed that on the tips of the wedge-shaped ingots, the minimum diameter of nano-QCs approach to 4~6 nm. The main size of nano-QCs is about 10~30 nm. The maximum microhardness of QCs has been dramatically improved to about HV440 which increased by about 280% compared with that of the petal-like QCs fabricated under common cast iron mold cooling conditions. Possessing a certain negative enthalpy of mixing and existence of Frank-Kasper-type phases determined the formation of Mg-Zn-Y-based nano-QCs. The further electrochemical studies showed that Mg71Zn26Y2Cu1 nano-QC alloy possess high corrosion resistance in simulated seawater and its corrosion resistance is much better than those of the Mg72Zn26Y2 and Mg71Zn26Y2Cu0.5 Ni0.5 nano-QC alloys.

  19. Improving the corrosion resistance of Mg–4.0Zn–0.2Ca alloy by micro-arc oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Y.H. [The First Affiliated Hospital of Harbin Medical University, Harbin 150001 (China); Zhang, B.P., E-mail: zhangbp@sxicc.ac.cn [National Engineering Laboratory for Carbon Fiber Technology, Institute of Coal Chemistry, Chinese Academy of Sciences, Taiyuan 030001 (China); Lu, C.X. [National Engineering Laboratory for Carbon Fiber Technology, Institute of Coal Chemistry, Chinese Academy of Sciences, Taiyuan 030001 (China); Geng, L. [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150001 (China)

    2013-12-01

    In this paper, corrosion resistance of the Mg–4.0Zn–0.2Ca alloy was modified by micro-arc oxidation (MAO) process. The microstructure and phase constituents of MAO layer were characterized by SEM, XRD and X-ray photoelectron spectroscopy (XPS). The corrosion resistance of MAO treated Mg–4.0Zn–0.2Ca alloy in the simulated body fluid were characterized by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The microstructure results indicated that a kind of ceramic film was composed by MgO and MgF{sub 2} was formed on the surface of Mg–4.0Zn–0.2Ca alloy after MAO treatment. The electrochemical test reveals that the corrosion resistance of MAO treated samples increase 1 order of magnitude. The mechanical intensity test showed that the MAO treated samples has suitable mechanical properties. - Highlights: • Ceramic layer which is composited by MgO and MgF{sub 2} is prepared to improve the corrosion resistance of Mg–4.0Zn–0.2Ca alloy. • MAO treatment does not affect the mechanical properties of the Mg–4.0Zn–0.2Ca alloy. • After 30-day immersion in SBF, the mechanical properties of MAO coated samples are still enough for bone fixed.

  20. Corrosion-resistant uranium

    Science.gov (United States)

    Hovis, V.M. Jr.; Pullen, W.C.; Kollie, T.G.; Bell, R.T.

    1981-10-21

    The present invention is directed to the protecting of uranium and uranium alloy articles from corrosion by providing the surfaces of the articles with a layer of an ion-plated metal selected from aluminum and zinc to a thickness of at least 60 microinches and then converting at least the outer surface of the ion-plated layer of aluminum or zinc to aluminum chromate or zinc chromate. This conversion of the aluminum or zinc to the chromate form considerably enhances the corrosion resistance of the ion plating so as to effectively protect the coated article from corrosion.

  1. [The effect of C-SiO2 composite films on corrosion resistance of dental Co-Cr alloy].

    Science.gov (United States)

    Huang, Yi; Hu, Jing-Yu; Liu, Yu-Pu; Zhao, Dong-Yuan; Yu, You-Cheng; Bi, Wei

    2016-10-01

    To study the effect of carbon-silica composite films on corrosion resistance of Co-Cr alloy in simulated oral environment and provide evidences for clinical application of this new material. Co-Cr alloy specimens were cut into appropriate size of 20 mm × 20 mm × 0.5 mm. Then, the carbon-silica composite films were spin-coated onto the specimens. Subsequently, ICP-AES was used to observe the Co, Cr, Mo ion concentrations. Finally, Tafel polarization curves of the specimens were used to measure the electrochemical corrosion resistance by electrochemical workstation. SAS8.0 software package was used for statistical analysis. The results of ICP-AES showed that the ion concentrations of Co, Cr, Mo of specimens coated with composite films in the testing liquid were significantly smaller than that of Co-Cr alloy specimens. Tafel polarization curves showed that in the specimens coated with composite films, the corrosion potential moved in the positive direction and increased from -0.261 V to -0.13 V. At the same time, the corrosion current density decreased from -5.0017μA/cm(2) to -5.3006 μA/cm(2). Carbon-silica composite films (silica=61.71wt %) can reduce the release of metal ions significantly and improve the corrosion resistance of Co-Cr alloys effectively. Carbon-silica composite films may be a promising dental material.

  2. Influence of Tensile Stresses on α+β – Titanium Alloy VT22 Corrosion Resistance in Marine Environment

    Directory of Open Access Journals (Sweden)

    Yu. A. Puchkov

    2015-01-01

    Full Text Available Tensile stresses and hydrogen render strong influence on the titanic alloys propensity for delayed fracture. The protective film serves аs a barrier for penetration in hydrogen alloy. Therefore to study the stress effect on its structure and protective properties is of significant interest.The aim of this work is to research the tensile stress influence on the passivation, indexes of corrosion, protective film structure and reveal reasons for promoting hydrogenation and emerging propensity for delayed fracture of titanium alloy VТ22 in the marine air atmosphere.The fulfillеd research has shown that:- there is а tendency to reduce the passivation abilities of the alloy VТ22 in synthetic marine water (3 % solution of NaCl with increasing tensile stresses up to 1170 МPа, namely to reduce the potential of free corrosion and the rate of its сhange, thus the alloy remains absolutely (rather resistant;- the protective film consists of a titanium hydroxide layer under which there is the titanium oxide layer adjoining to the alloy, basically providing the corrosion protection.- the factors providing hydrogenation of titanium alloys and formation in their surface zone fragile hydrides, causing the appearing propensity for delayed fracture, alongside with tensile stresses are:- substances promoting chemisorbtion of hydrogen available in the alloy and on its surface;- the cathodic polarization caused by the coupling;- the presence of the structural defects promoting the formation of pitting and local аcidifying of the environment surrounding the alloy.

  3. Passive Corrosion Behavior of Alloy 22

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; Payer, J H

    2006-01-10

    Alloy 22 (N06022) was designed to stand the most aggressive industrial applications, including both reducing and oxidizing acids. Even in the most aggressive environments, if the temperature is lower than 150 F (66 C) Alloy 22 would remain in the passive state having particularly low corrosion rates. In multi-ionic solutions that may simulate the behavior of concentrated ground water, even at near boiling temperatures, the corrosion rate of Alloy 22 is only a few nanometers per year because the alloy is in the complete passive state. The corrosion rate of passive Alloy 22 decreases as the time increases. Immersion corrosion testing also show that the newer generation of Ni-Cr-Mo alloys may offer a better corrosion resistance than Alloy 22 only in some highly aggressive conditions such as in hot acids.

  4. Passive Corrosion Behavior of Alloy 22

    Energy Technology Data Exchange (ETDEWEB)

    R.B. Rebak; J.H. Payer

    2006-01-20

    Alloy 22 (NO6022) was designed to stand the most aggressive industrial applications, including both reducing and oxidizing acids. Even in the most aggressive environments, if the temperature is lower than 150 F (66 C) Alloy 22 would remain in the passive state having particularly low corrosion rates. In multi-ionic solutions that may simulate the behavior of concentrated ground water, even at near boiling temperatures, the corrosion rate of Alloy 22 is only a few nano-meters per year because the alloy is in the complete passive state. The corrosion rate of passive Alloy 22 decreases as the time increases. Immersion corrosion testing also show that the newer generation of Ni-Cr-Mo alloys may offer a better corrosion resistance than Alloy 22 only in some highly aggressive conditions such as in hot acids.

  5. Improvement of corrosion resistance of AZ31 Mg alloy by anodizing with co-precipitation of cerium oxide

    Institute of Scientific and Technical Information of China (English)

    Salah Abdelghany SALMAN; Ryoichi ICHINO; Masazumi OKIDO

    2009-01-01

    Anodizing of AZ31 Mg alloy in NaOH solution by co-precipitation of cerium oxide was investigated. The chemical composition and phase structure of the coating film were determined via optical microscopy, SEM and XRD. The corrosion properties of the anodic film were characterized by using potentiodynamic polarization curves in 17 mmol/L NaCl and 0.1 mol/L Na2SO4 solution at 298 K. The corrosion resistance of AZ31 magnesium alloy is significantly improved by adding cerium oxide to alkaline solution. In addition, the surface properties are enhanced and the film contains no crack.

  6. Computer Simulation and Experimental Validation on the Oxidation and Sulfate Corrosion Resistance of Novel Chromium Based High Temperature Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Shizhong

    2013-02-28

    This report summarizes our recent works of ab initio molecular dynamics inter-atomic potentials development on dilute rare earth element yttrium (Y) etc. doped chromium (Cr) alloy systems, its applications in oxidation and corrosion resistance simulation, and experiment validation on the candidate systems. The simulation methods, experimental validation techniques, achievements already reached, students training, and future improvement are briefly introduced.

  7. Corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys for orthopedic implant applications.

    Science.gov (United States)

    Samuel, Sonia; Nag, Soumya; Nasrazadani, Seifollah; Ukirde, Vaishali; El Bouanani, Mohamed; Mohandas, Arunesh; Nguyen, Kytai; Banerjee, Rajarshi

    2010-09-15

    While direct metal deposition of metallic powders, via laser deposition, to form near-net shape orthopedic implants is an upcoming and highly promising technology, the corrosion resistance and biocompatibility of such novel metallic biomaterials is relatively unknown and warrants careful investigation. This article presents the results of some initial studies on the corrosion resistance and in vitro response of laser-deposited Ti-Nb-Zr-Ta alloys. These new generation beta titanium alloys are promising due to their low elastic modulus as well as due the fact that they comprise of completely biocompatible alloying elements. The results indicate that the corrosion resistance of these laser-deposited alloys is comparable and in some cases even better than the currently used commercially-pure (CP) titanium (Grade 2) and Ti-6Al-4V ELI alloys. The in vitro studies indicate that the Ti-Nb-Zr-Ta alloys exhibit comparable cell proliferation but enhanced cell differentiation properties as compared with Ti-6Al-4V ELI.

  8. Crevice corrosion resistance of high alloyed materials in 3.5 % NaCl solution

    Energy Technology Data Exchange (ETDEWEB)

    Alar, Vesna; Stojanovic, Ivan; Simunovic, Vinko [Zagreb Univ. (Croatia). Faculty of Mechanical Engineering and Naval Architecture; Novak, Tomislav [NMP Produkt Ltd., Nedelisce (Croatia)

    2014-06-15

    The effects of applied torque on the corrosion behaviour of W.-Nr. 1.4404 and 1.4462 stainless steels and W.-Nr. 2.4605 and 2.4858 nickel alloys with crevices were investigated using the cyclic potentiodynamic polarization method. Crevice corrosion (material-to-polytetrafluoroethylene) was tested in 3.5 % NaCl solution at 22 C. The corroded surface was examined using scanning electron microscopy. The results indicate similar trends in susceptibility to crevice corrosion with increasing torque. Among the four specimens, the W.-Nr. 1.4404 is the most susceptible to crevice corrosion. (orig.)

  9. Improvement of corrosion resistance of Nisbnd Mo alloy coatings: Effect of heat treatment

    Science.gov (United States)

    Mousavi, R.; Bahrololoom, M. E.; Deflorian, F.; Ecco, L.

    2016-02-01

    In this paper, Nisbnd Mo alloy coatings were deposited from bath containing sodium citrate, nickel sulphate, and sodium molybdate. Essentially, this work is divided into two mains parts: (i) the optimization on the coatings deposition parameters and (ii) the effect of the heat treatment. Polarization curves and electrochemical impedance spectroscopy were acquired using potentiostat/galvanostat and a frequency response analyzer, respectively. Morphology and chemical composition of the coatings were investigated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Polarization curves at different condition revealed that electroplating at temperature 40 oC, pH 9 provides a dense coating with high efficiency. Following the optimization of the deposition parameters, the coatings were annealed at 200, 400, and 600 oC for 25 min. The results showed that the coatings obtained at temperature 40 oC, pH 9, and annealing at 600 oC has the highest corrosion resistance and microhardness.

  10. An Influence of Ageing on the Structure, Corrosion Resistance and Hardness of High Aluminum ZnAl40Cu3 Alloy

    Directory of Open Access Journals (Sweden)

    Michalik R.

    2016-03-01

    Full Text Available Zn-Al-Cu alloys are used primarily because of their tribological properties as an alternative material for bronze, cast iron and aluminum alloy bearings and as a construction material. Particularly interesting are high aluminum zinc alloys. Monoeutectic zinc and aluminum alloys are characterized by the highest hardness, tensile strength and wear resistance of all of the zinc alloys. A significant problem with the use of the Zn-Al-Cu alloys is their insufficient resistance to electrochemical corrosion. Properties of Zn-Al-Cu alloys can be improved by heat treatment. The purpose of examination was to determine the effect of heat treatment (aging at various temperatures on the microstructure and corrosion resistance of the ZnAl40Cu3 alloy. The scope of the examination included: structural examinations, determination of hardness using Brinell’s method and corrosion resistance examinations. Ageing at higher temperatures causes a creation of areas where is an eutectoid mixture. The study showed that ageing causes a decrease in hardness of ZnAl40Cu3 alloy. This decrease is even greater, when the temperature of ageing is lower. The studies have shown a significant influence of ageing on the corrosion resistance of the alloy ZnAl40Cu3. Maximum corrosion resistance were characterized by the sample after ageing at higher temperatures.

  11. Nodular Corrosion Characteristics of Zirconium Alloys

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Gil; Jeong, Y. H.; Park, S. Y.; Lee, D. J

    2003-01-15

    This study was reported the effect of the nodular corrosion on the nuclear reactor environmental along with metallurgical influence, also suggested experimental scheme related to evaluate nodular corrosion characteristics of Zr-1 Nb alloy. Remedial strategies against the nodular corrosion should firstly develop plan to assess the effect of the water quality condition (Oxygen, Hydrogen) as well as the boiling on the nodular corrosion, secondarily establish plan to control heat treatment process to keep a good resistance on nodular corrosion in Zr-1Nb alloy as former western reactor did.

  12. Hybrid framework with cobalt-chromium alloy and gold cylinder for implant superstructure: Bond strength and corrosion resistance.

    Science.gov (United States)

    Yoshinari, Masao; Uzawa, Shinobu; Komiyama, Yataro

    2016-10-01

    The aim of this in vitro study was to evaluate tensile bond strengths and corrosion resistance of CoCr alloys joined with gold cylinder by a soldering system in comparison with the conventional cast-joining system. CoCr alloys joined with gold cylinder by a soldering system using a high-fusing gold solder (CoCr/Solder/Gold cylinder), gold alloy joined with gold cylinder by a cast joining system (Gold alloy/Gold cylinder) and CoCr castings were fabricated. The tensile bond strength and corrosion resistance in 0.9% NaCl solution (pH 7.4 and pH 2.3) were evaluated. Scanning electron microscopy (SEM) of the fractured surface and electron probe microanalysis (EPMA) of the joined interfaces were also performed. The tensile bond strengths of the CoCr/Solder/Gold cylinder specimens showed similar values as the Gold alloy/Gold cylinder specimens. SEM observation and EPMA analyses suggested firm bonding between the CoCr alloy and gold cylinder. The released elements from the CoCr/Solder/Gold cylinder specimens were similar to ones from CoCr castings. Results showed that superstructures made of CoCr alloys joined with the gold cylinder using a high-fusing gold solder had sufficient bond strength and high corrosion resistance. These hybrid frameworks with cobalt-chromium alloy and gold cylinder are promising prosthesis for implant superstructures with the low cost and favorable mechanical properties instead of conventional high-gold alloys. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  13. Corrosion Resistance of the Superhydrophobic Mg(OH2/Mg-Al Layered Double Hydroxide Coatings on Magnesium Alloys

    Directory of Open Access Journals (Sweden)

    Fen Zhang

    2016-04-01

    Full Text Available Coatings of the Mg(OH2/Mg-Al layered double hydroxide (LDH composite were formed by a combined co-precipitation method and hydrothermal process on the AZ31 alloy substrate in alkaline condition. Subsequently, a superhydrophobic surface was successfully constructed to modify the composite coatings on the AZ31 alloy substrate using stearic acid. The characteristics of the composite coatings were investigated by means of X-ray diffractometer (XRD, Fourier transform infrared spectroscopy (FTIR, X-ray photoelectron spectroscopy (XPS, scanning electronic microscope (SEM and contact angle (CA. The corrosion resistance of the coatings was assessed by potentiodynamic polarization, the electrochemical impedance spectrum (EIS, the test of hydrogen evolution and the immersion test. The results showed that the superhydrophobic coatings considerably improved the corrosion resistant performance of the LDH coatings on the AZ31 alloy substrate.

  14. A Study of Magnesium-Base Metallic Systems and Development of Principles for Creation of Corrosion-Resistant Magnesium Alloys

    Science.gov (United States)

    Mukhina, I. Yu.

    2014-11-01

    The effect of 26 alloying elements on the corrosion resistance of high-purity magnesium in a 0.5-n solution of sodium chloride and in a humid atmosphere (0.005 n) is studied. The Mg - Li, Mg - Ag, Mg - Zn, Mg - Cu, Mg - Gd, Mg - Al, Mg - Zr, Mg - Mn and other binary systems, which present interest as a base for commercial or perspective castable magnesium alloys, are studied. The characteristics of corrosion resistance of the binary alloys are analyzed in accordance with the group and period of the Mendeleev's periodic law. The roles of the electrochemical and volume factors and of the factor of the valence of the dissolved element are determined.

  15. Robust Slippery Coating with Superior Corrosion Resistance and Anti-Icing Performance for AZ31B Mg Alloy Protection.

    Science.gov (United States)

    Zhang, Jialei; Gu, Changdong; Tu, Jiangping

    2017-03-29

    Biomimetic slippery liquid-infused porous surfaces (SLIPSs) are developed as a potential alternative to superhydrophobic surfaces (SHSs) to resolve the issues of poor durability in corrosion protection and susceptibility to frosting. Herein, we fabricated a double-layered SLIPS coating on the AZ31 Mg alloy for corrosion protection and anti-icing application. The porous top layer was infused by lubricant, and the compact underlayer was utilized as a corrosion barrier. The water-repellent SLIPS coating exhibits a small sliding angle and durable corrosion resistance compared with the SHS coating. Moreover, the SLIPS coating delivers durable anti-icing performance for the Mg alloy substrate, which is obviously superior to the SHS coating. Multiple barriers in the SLIPS coating, including the infused water-repellent lubricant, the self-assembled monolayers coated porous top layer, and the compact layered double hydroxide-carbonate composite underlayer, are suggested as being responsible for the enhanced corrosion resistance and anti-icing performance. The robust double-layered SLIPS coating should be of great importance to expanding the potential applications of light metals and their alloys.

  16. Influence of Alloying Elements Corrosion Resistance of Cold on Mechanical Properties and Rolled C-Mn-Si TRIP Steels

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ling-yun; WU Di; LI Zhuang

    2012-01-01

    The rust layer plays an important role in the corrosion of steel in chlorinated environments. Salt spray, po- tentiodynamic polarization curve and tensile test were conducted in laboratory for the specimens after two-stage heat treatment. The influence of the alloying elements on mechanical properties and corrosion resistance of three kinds of steels was investigated by observing the microstructure and the morphologies of rust layer. The results show that the highest value (29%) of total elongation for steel A is obtained. The mechanical property of the specimen for steel C exhibits best strength ductility balance (21 384 MPa ·%) because of the presence of the multiphase microstructures after a two-stage heat treatment and the addition of the alloying elements. The corrosion products are known to be a complex mixture of Fe3O4 , Fe2O3 and α-FeOOH for steel C. The presence of the alloying elements results in the for mation of compact and dense rust layers in steel B and C. Passive film protects the substrate of TRIP (transformation induced plasticity) steel containing a complex mix of multiphase. Superior corrosion performance is exhibited for steel C with low alloying contents due to the enrichment of alloying elements within the rust layers.

  17. Mechanical properties and corrosion resistance of low rigidity quaternary titanium alloy for biomedical applications

    Institute of Scientific and Technical Information of China (English)

    Han-Cheol CHOE; Viswanathan S. SAJI; Yeong-Mu KO

    2009-01-01

    Electrochemical corrosion of Ti-35Nb-5Ta-7Zr alloy fabricated by arc melting and heat treatment process was studied in 0.9% NaCl at (37±1) ℃. Phase and microstructure of the fabricated alloy were investigated using X-ray diffractometer and scanning electron microscope. Mechanical properties such as yield strength and elastic modulus of the alloy were determined by tensile test. Potentiodynamic polarization technique and impedance spectroscopy were employed to study the corrosion behavior. The results of the study were compared with those obtained for Ti-6Al-4V commercial alloy. The result of the study supports feasibility of Ti-35Nb-5Ta-7Zr alloy for implant applications.

  18. Improvement of corrosion resistance of Ni−Mo alloy coatings: Effect of heat treatment

    Energy Technology Data Exchange (ETDEWEB)

    Mousavi, R., E-mail: mousavi@scu.ac.ir [Department of Materials Science and Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Bahrololoom, M.E. [Department of Materials Science and Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of); Deflorian, F.; Ecco, L. [Department of Industrial Engineering, University of Trento, via Sommarive 9, Trento (Italy)

    2016-02-28

    Graphical abstract: - Highlights: • Conjunction between SEM, EIS, and Tafel measurements to obtain a coat with dense morphology and without crack. • An inverse Hall-Petch effect is observed after annealing the coatings, i.e. the coatings get harder as the grain size is increased by increasing annealing temperature up to 600 {sup o}C. • Heat treatment can improve the mechanical and corrosion properties of coatings. - Abstract: In this paper, Ni−Mo alloy coatings were deposited from bath containing sodium citrate, nickel sulphate, and sodium molybdate. Essentially, this work is divided into two mains parts: (i) the optimization on the coatings deposition parameters and (ii) the effect of the heat treatment. Polarization curves and electrochemical impedance spectroscopy were acquired using potentiostat/galvanostat and a frequency response analyzer, respectively. Morphology and chemical composition of the coatings were investigated by scanning electron microscopy and energy dispersive spectroscopy, respectively. Polarization curves at different condition revealed that electroplating at temperature 40 {sup o}C, pH 9 provides a dense coating with high efficiency. Following the optimization of the deposition parameters, the coatings were annealed at 200, 400, and 600 {sup o}C for 25 min. The results showed that the coatings obtained at temperature 40 {sup o}C, pH 9, and annealing at 600 {sup o}C has the highest corrosion resistance and microhardness.

  19. Testing and prediction of erosion-corrosion for corrosion resistant alloys used in the oil and gas production industry

    Science.gov (United States)

    Rincon, Hernan E.

    The corrosion behavior of CRAs has been thoroughly investigated and documented in the public literature by many researchers; however, little work has been done to investigate erosion-corrosion of such alloys. When sand particles are entrained in the flow, the degradation mechanism is different from that observed for sand-free corrosive environment. There is a need in the oil and gas industry to define safe service limits for utilization of such materials. The effects of flow conditions, sand rate, pH and temperature on the erosion-corrosion of CRAs were widely studied. An extensive experimental work was conducted using scratch tests and flow loop tests using several experimental techniques. At high erosivity conditions, a synergistic effect between erosion and corrosion was observed. Under the high sand rate conditions tested, erosivity is severe enough to damage the passive layer protecting the CRA thereby enhancing the corrosion rate. In most cases there is likely a competition between the rates of protective film removal due to mechanical erosion and protective film healing. Synergism occurs for each of the three alloys examined (13Cr and Super13Cr and 22Cr); however, the degree of synergism is quite different for the three alloys and may not be significant for 22Cr for field conditions where erosivities are typically much lower that those occurring in the small bore loop used in this research. Predictions of the corrosion component of erosion-corrosion based on scratch test data compared reasonably well to test results from flow loops for the three CRAs at high erosivity conditions. Second order behavior appears to be an appropriate and useful model for representing the repassivation process of CRAs. A framework for a procedure to predict penetration rates for erosion-corrosion conditions was developed based on the second order model behavior observed for the re-healing process of the passive film of CRAs and on computational fluid dynamics (CFD) simulations

  20. Improving hot corrosion resistance of two phases intermetallic alloy α2-Ti3Al/γ-TiAl with enamel coating

    Science.gov (United States)

    Pambudi, Muhammad Jajar; Basuki, Eddy Agus; Prajitno, Djoko Hadi

    2017-01-01

    TiAl intermetallic alloys have attracted great interest among aerospace industry after successful utilization in low pressure turbine blades of aircraft engine which makes dramatic weight saving up to 40% weight saving. However, poor oxidation and corrosion resistance at temperatures above 800°C still become the drawbacks of this alloys, making the development of protective coatings to improve the resistance is important. This study investigates the hot corrosion behavior of two phases intermetallic alloy α2-Ti3Al/γ-TiAl with and without enamel coating using immersion test method in molten salt of 85%-wt Na2SO4 and 15%-wt NaCl at 850°C. The results show after 50 hours of hot corrosion test, bare alloy showed poor hot corrosion resistance due to the formation of non-protective Al2O3+TiO2 mixed scale at the surface of the alloy. Improvement of hot corrosion resistance was obtained in samples protected with enamel coating, indicated by significant decreasing in mass change (mg/cm2) by 98.20%. Enamel coating is expected to has the capability in suppressing the diffusion of oxygen and corrosive ions into the substrate layer, and consequently, it improves hot corrosion resistance of the alloy. The study showed that enamel coatings have strong adherent to the substrate and no spallation was observed after hot corrosion test. Nevertheless, the dissolution of oxides components of the enamel coating into the molten salts was observed that lead enamel coating degradation. This degradation is believed involving Cl- anion penetration into the substrate through voids in the coating that accelerates the corrosion of the two phases α2-Ti3Al/γ-TiAl alloy. Even though further observations are needed, it appears that enamel coating could be a promising protective coating to increase hot corrosion resistance of TiAl intermetallic alloys.

  1. Enhanced corrosion resistance and biocompatibility of AZ31 Mg alloy using PCL/ZnO NPs via electrospinning

    Science.gov (United States)

    Kim, Jinwoo; Mousa, Hamouda M.; Park, Chan Hee; Kim, Cheol Sang

    2017-02-01

    In the efforts to improve corrosion resistance and biocompatibility of magnesium alloys, polycarprolactone (PCL) and zinc oxide nanoparticles (ZnO NPs) composite coatings were applied onto AZ31 Mg alloys via electrospinning technique in this study. The PCL/ZnO composite coatings on Mg alloys were characterized by using FE-SEM, EDX, XPS, and FT-IR. Moreover, coating adhesion test, electrochemical corrosion test, and biocompatibility test in vitro were performed to measure coating performance. Our results revealed that the increase in the content of ZnO NPs in the composite coatings not only improved the coating adhesion of composite coatings on Mg alloys, but also increased the corrosion resistance. Furthermore, the biocompatibility of MC3T3-E1 osteoblasts of the PCL/ZnO composite coated samples was superior to the biocompatibility of the bare samples. Such data suggest that applying PCL/ZnO composite coating to the magnesium alloys has suitable potential in biomedical applications.

  2. CORRELATION BETWEEN MICROSTRUCTURE AND MECHANICAL AND CORROSION RESISTANCES OF A LEAD-FREE Sn-0,7%Cu SOLDER ALLOY

    Directory of Open Access Journals (Sweden)

    José Eduardo Spinelli

    2014-12-01

    Full Text Available Sn-Cu alloys are promising alternatives to the replacement of Pb-containing solder alloys. However, the effects of the cooling rate on the solidification microstructures of these alloys and the corresponding influence on the mechanical and corrosion resistances are not well known. In the present study, the transient directional solidification technique has been used to obtain a Sn-0,7wt.%Cu ingot. The experimental results include: solidification thermal parameters (cooling rate, Ṫ, growth rate, v, and metal/substrate heat transfer coefficient, hi , cellular spacing, λc , and primary dendritic arm spacing, λ1 , corrosion rate, corrosion potential and polarization resistance and mechanical strength and ductility. The results show a cellular/dendritic transition with eutectic cells prevailing for Ṫ< 0,9°C/s. Lower corrosion resistances have been associated with dendritic regions compared with regions characterized by eutectic cells. In the interdendritic regions extremely fine and fibrous Cu6 Sn5 intermetallic particles can be observed.

  3. Effects of Tungsten Addition on the Microstructure and Corrosion Resistance of Fe-3.5B Alloy in Liquid Zinc.

    Science.gov (United States)

    Liu, Xin; Wang, Mengmeng; Yin, Fucheng; Ouyang, Xuemei; Li, Zhi

    2017-04-10

    The effects of tungsten addition on the microstructure and corrosion resistance of Fe-3.5B alloys in a liquid zinc bath at 520 °C were investigated by means of scanning electron microscopy, X-ray diffraction and electron probe micro-analysis. The microstructure evolution in different alloys is analyzed and discussed using an extrapolated Fe-B-W ternary phase diagram. Experimental results show that there are three kinds of borides, the reticular (Fe, W)₂B, the rod-like (Fe, W)₃B and flower-like FeWB. The addition of tungsten can refine the microstructure and improve the stability of the reticular borides. Besides, it is beneficial to the formation of the metastable (Fe, W)₃B phase. The resultant Fe-3.5B-11W (wt %) alloy possesses excellent corrosion resistance to liquid zinc. When tungsten content exceeds 11 wt %, the formed flower-like FeWB phase destroys the integrity of the reticular borides and results in the deterioration of the corrosion resistance. Also, the corrosion failure resulting from the spalling of borides due to the initiation of micro-cracks in the grain boundary of borides is discussed in this paper.

  4. Corrosion resistance of stainless steels and high Ni-Cr alloys to acid fluoride wastes

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.D.; Mackey, D.B.; Pool, K.H. [Pacific Northwest Lab., Richland, WA (United States); Schwenk, E.B. [Westinghouse Hanford Co., Richland, WA (United States)

    1992-04-01

    TRUEX processing of Hanford Site waste will utilize potentially corrosive acid fluoride processing solutions. Appropriate construction materials for such a processing facility need to be identified. Toward this objective, candidate stainless steels and high Ni-Cr alloys have been corrosion tested in simulated acid fluoride process solutions at 333K. The high Ni-Cr alloys exhibited corrosion rates as low as 0.14 mm/y in a solution with an HF activity of about 1.2 M, much lower than the 19 to 94 mm/y observed for austenitic stainless steels. At a lower HF activity (about 0.008 M), stainless steels display delayed passivation while high Ni-Cr alloys display essentially no reaction.

  5. Environmental friendly plasma electrolytic oxidation of AM60 magnesium alloy and its corrosion resistance

    Institute of Scientific and Technical Information of China (English)

    CAO Fa-he; LIN Long-yong; ZHANG Zhao; ZHANG Jian-qing; CAO Chu-nan

    2008-01-01

    Plasma electrolytic oxidation of Mg-based AM60 alloys was investigated using 50 Hz AC anodizing technique in an alkaline borate solution, which contained a new kind of organic. The anodic film is relatively smooth with some micro pores and cracks, while the anodic film consists of MgO, MgAl2O4 and MgSiO3. The electrochemical behavior of anodic film was studied by electrochemical impedance spectroscopy and potentiodynamic polarization. Polarization results indicate the PEO treatment can decrease corrosion current by 3-4 magnitude compared with blank AM60 alloy. The anodic film presents a good level of corrosion protection for AM60 magnesium alloy, over 272 h of the salt spray test based on ASTM B117. The effect of micro-structure and composition on corrosion protection efficiency was also investigated.

  6. Synthesis of Corrosion-resistant Nanocrystalline Nickle-copper Alloy Coatings by Pulse-plating Technique

    Directory of Open Access Journals (Sweden)

    S.K. Ghosh

    2005-01-01

    Full Text Available Bright and smooth nanocrystalline Monel-type Ni-Cu alloy gets deposited from complex citrate electrolyte by pulse electrolysis. Transmission electron microscopy studies have revealedthat the deposited Ni-Cu alloy was nanocrystalline in nature and it comprised a two-phase (fcc+Ll, mixture. The presence of twins could be seen in the nanocrystals. The Ni-Cu alloysprepared by pulse electrolysis were finer grained (- 2.5-28.5 nm than those deposited by direct current method. Nelson-Riley function has been used to calculate the lattice parameters for both the pulse current-plated and direct current-plated alloys from x-ray diffraction analysis. The microhardness values for pulse current-plated alloys were higher than for the direct currentplated alloys. The internal stresses of both the pulse current-deposited and the direct currentdeposited alloys have also been measured; the values were lower for pulse current-plated alloys. Potentiodynamic polarisation studies were carried out in aerated and deaerated neutral 3.0 Wt per cent NaCl solution and instantaneous corrosion current density of the plated alloy was determined and compared with the Monel-400 alloy. It was found that nanocrystalline pulse current-N,-35 8 Wt p;r cent copper alloy uxh~bitedlo wer instantaneous value of corros~onc urrent densirv than that of soeclrnens with direct current method and Monel-400 allov The d~ssolut~on ~ ~~~~-~ behaviour ofthe deposited nanocrystalline material was found to be more like general corrosion rather than localised corrosion as in the case of Monel-400 alloy.

  7. Effect of combinative addition of strontium and rare earth elements on corrosion resistance of AZ91D magnesium alloy

    Institute of Scientific and Technical Information of China (English)

    NIU Jie-xin; CHEN Qiu-rong; XU Nai-xin; WEI Zhong-ling

    2008-01-01

    The influence of strontium(Sr) and rare earth(RE) elements on the corrosion behavior of AZ91D magnesium alloy was investigated by conventional corrosion testing and electrochemical measurements in 3.5% NaCI solution. After comparing the mass loss and hydrogen evolution of the samples, the microstruetures of the alloys and the morphologies of their corrosion product films were characterized by electron probe microanalysis-energy dispersive spectrometry(EPMA-EDS) and Auger electron spectroscopy(AES). Compared with individual addition of Sr or RE to AZ91D, the combinative addition of 0.5% Sr and 1% RE to AZ91D successfully decreases the corrosion rate further, which can be attributed to the depression of micro-galvanic couples, as well as the formation of more protective film due to aluminum enrichment. The combinative addition of strontium and rare earth elements to AZ91D magnesium alloy appears to he a promising approach to increase its corrosion resistance.

  8. Improvement of abrasion resistance in artificial seawater and corrosion resistance in NaCl solution of 7075 aluminum alloy processed by laser shock peening

    Science.gov (United States)

    Wang, Hao; Ning, Chengyi; Huang, Yihui; Cao, Zhenya; Chen, Xiaoxiao; Zhang, Wenwu

    2017-03-01

    As 7075 aluminum alloy is widely used in a humid environment, in order to enhance its abrasion resistance and electrochemical corrosion resistance, the paper studied the effect of laser shock peening on abrasion resistance in artificial seawater and corrosion resistance in 3.5% NaCl solution of 7075 aluminum alloy. Result shows that when specimens were treated once and twice with 7.17 GW/cm2 the abrasion loss would be reduced by 43.75% and 46.09% compare to untreated respectively, and the corrosion rate of 7075 aluminum alloy could be reduced as much as 50.32% by LSP treatment with 7.17 GW/cm2. What's more, the effects on the microhardness, microstructure and residual stress with different LSP impacts and power density were investigated to find out strengthening mechanism of laser shock peening, which were observed and measured by microhardness tester, optical microscope and X-ray diffraction (XRD) residual stress tester. In the entire laboratory tests, it is considered that LSP is a practical option to improve abrasion resistance in seawater and corrosion resistance of 7075 aluminum alloy.

  9. The Effect of Chemical Composition and Structure on the Corrosion Resistance of Plated Aluminium Alloy Strips

    Science.gov (United States)

    Klyszewski, Andrzej; Zelechowski, Janusz; Opyrchal, Mieczyslaw; Nowak, Marek; Frontczak, Andrzej; Rutecki, Pawel

    Thin 3003 alloy strips plated with 4343 alloy were subjected to microstructure examinations, X-ray phase analysis, corrosion testing, and measurement of basic mechanical properties. In a similar manner, the properties of heat exchangers made from the plated strip were characterised, watching the long-term consequences of their use in vehicles. The results of investigations were applied in the manufacturing technology of thin plated strips for heat exchangers used by the automotive industry.

  10. An overview of NiTi shape memory alloy: Corrosion resistance and antibacterial inhibition for dental application

    Energy Technology Data Exchange (ETDEWEB)

    Fadlallah, Sahar A., E-mail: sahar.fadlallah@yahoo.com [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Chemistry Department, Faculty of Science, Cairo University, Cairo (Egypt); El-Bagoury, Nader [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Casting Technology Lab., Manufacturing Technology Dept., CMRDI, P.O. Box 87, Helwan, Cairo (Egypt); Gad El-Rab, Sanaa M.F. [Biotechnology Department, Faculty of Science, Taif University, Taif (Saudi Arabia); Botany Department, Faculty of Science, Asuit University, Asuit (Egypt); Ahmed, Rasha A. [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia); Forensic Chemistry Laboratories, Medico Legal Department, Ministry of Justice, Cairo (Egypt); El-Ousamii, Ghaida [Materials and Corrosion Lab. (MCL), Faculty of Science, Taif University, Taif (Saudi Arabia)

    2014-01-15

    Highlights: • Evaluate the corrosion resistance of NiTi alloy by using electrochemical techniques. • Estimate the Antibacterial inhibition rate of NiTi alloy. • Assessment the mechanical properties of NiTi from the hardness measurements. • Comparsion the microstructures of cast NiTi with Ti, this indicate the role of Ni to change the behavior of alloy in oral environment. • Advise drinking green tea in small quantities in small quantities in the event of present NiTi alloy in the oral cavity. • Recommendation to use NiTi for dental application. -- Abstract: Nowadays, Nickel–titanium nearly equiatomic is considered as one of the best biomaterials. The aim of the present work deals with the evolution of the electrochemical behavior of NiTi in simulated oral environment. The hardness, microstructures corrosion resistance and antibacterial performance of NiTi alloy were compared with pure titanium. The hardness of NiTi is twice the hardness of pure titanium. Electrochemical techniques were used to detect the corrosion resistance of both biomaterials in Hank’s solution containing (−)-epigallocatechin gallate (EGCG) which used to simulate the oral environment. In the physiological solution selected for the present study, the impedance spectroscopy (EIS) results showed that EGCG sharply increase the corrosion resistance of NiTi from 129 kΩ cm{sup 2} to 1.10 T Ω cm{sup 2} while slowly increase the corrosion resistance of pure titanium from 9.4 kΩ cm{sup 2} to 11.3 kΩ cm{sup 2} during the duration time of immersion at 37 °C. The plate-counting method was used to evaluate the antibacterial performance against Staphylococcus aureus (ATCC 6538). Among the two specimens of biomaterials studied, the antibacterial performance results revealed that the NiTi alloy is better than the pure titanium. The morphology and chemical structure of NiTi and Ti samples were systematically investigated by scanning electron microscope (SEM) and energy dispersive X

  11. Surface Characterization, Corrosion Resistance and in Vitro Biocompatibility of a New Ti‐Hf‐Mo‐Sn Alloy

    Directory of Open Access Journals (Sweden)

    Raluca Ion

    2016-10-01

    Full Text Available A new superelastic Ti‐23Hf‐3Mo‐4Sn biomedical alloy displaying a particularly large recovery strain was synthesized and characterized in this study. Its native passive film is very thick (18 nm and contains very protective TiO2, Ti2O3, HfO2, MoO2, and SnO2 oxides (XPS analysis. This alloy revealed nobler electrochemical behavior, more favorable values of the corrosion parameters and open circuit potentials in simulated body fluid in comparison with commercially pure titanium (CP‐Ti and Ti‐6Al‐4V alloy taken as reference biomaterials in this study. This is due to the favorable influence of the alloying elements Hf, Sn, Mo, which enhance the protective properties of the native passive film on alloy surface. Impedance spectra showed a passive film with two layers, an inner, capacitive, barrier, dense layer and an outer, less insulating, porous layer that confer both high corrosion resistance and bioactivity to the alloy. In vitro tests were carried out in order to evaluate the response of Human Umbilical Vein Endothelial Cells (HUVECs to Ti‐23Hf‐3Mo‐4Sn alloy in terms of cell viability, cell proliferation, phenotypic marker expression and nitric oxide release. The results indicate a similar level of cytocompatibility with HUVEC cells cultured on Ti‐23Hf‐3Mo‐4Sn substrate and those cultured on the conventional CP‐Ti and Ti‐6Al‐4V metallic materials.

  12. Strength, corrosion resistance, and biocompatibility of ultrafine-grained Mg alloys after different modes of severe plastic deformation

    Science.gov (United States)

    Dobatkin, S. V.; Lukyanova, E. A.; Martynenko, N. S.; Anisimova, N. Yu; Kiselevskiy, M. V.; Gorshenkov, M. V.; Yurchenko, N. Yu; Raab, G. I.; Yusupov, V. S.; Birbilis, N.; Salishchev, G. A.; Estrin, Y. Z.

    2017-05-01

    The effect of severe plastic deformation on the structure, mechanical properties, corrosion resistance, and biocompatibility of the WE43 (Mg-Y-Nd-Zr) alloy earmarked for applications as bioresorbable material has been studied. The alloy was deformed by rotary swaging (RS), equal channel angular pressing (ECAP), and multiaxial deformation (MAD). The microstructure examination by transmission electron microscopy showed that all SPD modes lead to the formation of ultrafine-grained structure with a structural element size of 0.5-1 µm and the Mg12Nd phase particles 0.3 µm in size. The microstructure refinement by all three treatments resulted in strengthening of the alloy. ECAP and MAD also raised ductility to up to 12-17%, while RS increased the ultimate tensile strength to up to 415 MPa. The study of the corrosion properties showed that SPD does not affect the electrochemical corrosion of the alloy. Its biocompatibility in vitro was estimated after incubation of the samples with red blood cells (hemolysis study), white blood cells (cell viability assay), and mesenchymal stromal cells (cell proliferation analysis). The biodegradation rate in fetal bovine serum was also evaluated. ECAP and MAD were found to cause some deceleration of biodegradation by slowing down the gas formation in the biological fluid and, compared to MSC, to improve the biocompatibility of the WE43 alloy.

  13. [Corrosion resistance and wear resistance of Ni-Cr alloy after coating titanium nitride (TiN) in oral containing fluorine environment].

    Science.gov (United States)

    Weng, Wei-Min; Yu, Wei-Qiang; Shan, Wei-Lan; Zhang, Fu-Qiang

    2010-12-01

    The aim of this study was to evaluate the corrosion resistance and wear resistance of Ni-Cr alloy after coating titanium nitride (TiN) in oral containing fluorine environment. Physical vapor deposition was established to coat titanium nitride (TiN) on the surface of dental cast Ni-Cr alloy to form TiN/Ni-Cr compound. Both Ni-Cr alloy and TiN/Ni-Cr compound were exposed to 37 degrees centigrade, artificial saliva containing 0.24% NaF. The polarization curves of the specimens were measured by PARSTAT 2273 electrochemical station to investigate its corrosion resistance. Vicker's hardness was measured by HXD-1000TMC/LCD micro-hardness tester to investigate its wear resistance. Statistical analysis was performed by SAS 8.2 software package for Student's t methods. The corrosion potential of Ni-Cr alloy was -362.407 mV, the corrosion current density was 1.568μAcm(-2),the blunt-breaking potential was 426 mV bofor TiN coating. The corrosion potential of TiN/Ni-Cr compound was -268.638 mV, the corrosion current density was 0.114μAcm(-2),the blunt-breaking potential was 1142 mV after TiN coating. Polarization curves showed TiN/Ni-Cr compound improved the corrosion potential and blunt-breaking potential, decreased the corrosion current density. The Vicker's hardness of Ni-Cr alloy was 519.75±27.27 before TiN coating, the Vicker's hardness of TiN/Ni-Cr compound was 803.24±24.64, the D-value between them was 283.49±39.34. The difference of Vicker's harnesses between Ni-Cr alloy and TiN/Ni-Cr compound had significant (Pcoating can improve the corrosion resistant to F-and the surface hardness of Ni-Cr alloy. Supported by Research Fund of Science and Technology Commission of Shanghai Municipality (Grant No.08DZ2271100), Shanghai Leading Academic Discipline Project (Grant No.S30206 ) and Research Fund of Health Bureau of Shanghai Municipality (Grant No.2009074).

  14. Corrosion resistance of Zn-Co-Fe alloy coatings on high strength steel

    NARCIS (Netherlands)

    Lodhi, Z.F.; Mol, J.M.C.; Hovestad, A.; Hoen-Velterop, L. 't; Terryn, H.; Wit, J.H.W.de

    2009-01-01

    The corrosion properties of electrodeposited zinc-cobalt-iron (Zn-Co-Fe) alloys (up to 40 wt.% Co and 1 wt.% Fe) on steel were studied by using various electrochemical techniques and compared with zinc (Zn) and cadmium (Cd) coatings in 3.5% NaCl solution. It was found that with an increase in Co con

  15. A Comparison of the Corrosion Resistance of Iron-Based Amorphous Metals and Austenitic Alloys in Synthetic Brines at Elevated Temperature

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, J C

    2008-11-25

    Several hard, corrosion-resistant and neutron-absorbing iron-based amorphous alloys have now been developed that can be applied as thermal spray coatings. These new alloys include relatively high concentrations of Cr, Mo, and W for enhanced corrosion resistance, and substantial B to enable both glass formation and neutron absorption. The corrosion resistances of these novel alloys have been compared to that of several austenitic alloys in a broad range of synthetic brines, with and without nitrate inhibitor, at elevated temperature. Linear polarization and electrochemical impedance spectroscopy have been used for in situ measurement of corrosion rates for prolonged periods of time, while scanning electron microscopy (SEM) and energy dispersive analysis of X-rays (EDAX) have been used for ex situ characterization of samples at the end of tests. The application of these new coatings for the protection of spent nuclear fuel storage systems, equipment in nuclear service, steel-reinforced concrete will be discussed.

  16. Corrosion resistance characteristics of a Ti-6Al-4V alloy scaffold that is fabricated by electron beam melting and selective laser melting for implantation in vivo.

    Science.gov (United States)

    Zhao, Bingjing; Wang, Hong; Qiao, Ning; Wang, Chao; Hu, Min

    2017-01-01

    The purpose of this study is to determine the corrosion resistance of Ti-6Al-4V alloy fabricated with electron beam melting and selective laser melting for implantation in vivo. Ti-6Al-4V alloy specimens were fabricated with electron beam melting (EBM) and selective laser melting (SLM). A wrought form of Ti-6Al-4V alloy was used as a control. Surface morphology observation, component analysis, corrosion resistance experimental results, electrochemical impedance spectroscopy, crevice corrosion resistance experimental results, immersion test and metal ions precipitation analysis were processed, respectively. The thermal stability of EBM specimen was the worst, based on the result of open circuit potential (OCP) result. The result of electrochemical impedance spectroscopy indicated that the corrosion resistance of the SLM specimen was the best under the low electric potential. The result of potentiodynamic polarization suggested that the corrosion resistance of the SLM specimen was the best under the low electric potential (1.5V).The crevice corrosion resistance of the EBM specimen was the best. The corrosion resistance of SLM specimen was the best, based on the result of immersion test. The content of Ti, Al and V ions of EBM, SLM and wrought specimens was very low. In general, the scaffolds that were fabricated with EBM and SLM had good corrosion resistance, and were suitable for implantation in vivo. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. The fluoride coated AZ31B magnesium alloy improves corrosion resistance and stimulates bone formation in rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Wei; Zhang, Guangdao [Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang 110001 (China); Tan, Lili; Yang, Ke [Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016 (China); Ai, Hongjun, E-mail: aihongjuna@sina.com [Department of Prosthodontics, School of Stomatology, China Medical University, Shenyang 110001 (China)

    2016-06-01

    This study aimed to evaluate the effect of fluorine coated Mg alloy and clarify its mechanism in bone formation. We implanted the fluorine coated AZ31B Mg alloy screw (group F) in rabbit mandibular and femur in vivo. Untreated AZ31B Mg alloy screw (group A) and titanium screw (group T) were used as control. Then, scanning electron microscopy, the spectral energy distribution analysis, hard and decalcified bone tissues staining were performed. Immunohistochemistry was employed to examine the protein expressions of bone morphogenetic protein 2 (BMP-2) and collagen type I in the vicinity of the implant. Compared with the group A, the degradation of the alloy was reduced, the rates of Mg corrosion and Mg ion release were slowed down, and the depositions of calcium and phosphate increased in the group F in the early stage of implantation. Histological results showed that fluorine coated Mg alloy had well osteogenic activity and biocompatibility. Moreover, fluoride coating obviously up-regulated the expressions of collagen type I and BMP-2. This study confirmed that the fluorine coating might improve the corrosion resistance of AZ31B Mg alloy and promote bone formation by up-regulated the expressions of collagen type I and BMP-2. - Highlights: • Fluoride coating inhibited the degradation of the alloy in the early implantation. • Fluorine coating could slow down the rate of Mg corrosion and Mg ion release. • Fluorine coating could promote the deposition of Ca and P in vivo. • Fluorine coated Mg alloy had well osteogenic activity and biocompatibility. • Fluorine coating up-regulated the expression of BMP-2 and collagen type I protein.

  18. Electrochemical Fabrication and Characterization of Corrosion-Resistant, Ternary, Lead-Based Alloys as a New Material for Steel Surface Protection

    Science.gov (United States)

    Aliyev, A. Sh.; Tahirli, H. M.; Elrouby, Mahmoud; Soltanova, N. Sh.; Tagiev, D. B.

    2016-06-01

    This article presents the study of the synthesis of the ternary Pb-Sb-Te alloy on the stainless steel substrate via electrochemical method. The corrosion resistance of the electrodeposited alloy has been investigated via subjecting the electro-synthesized alloy to a corrosive medium containing sulfide ions; this medium is similar to the petroleum refining environment. The resulting film of the electrodeposited alloy was analyzed by the scanning electron microscope, energy-dispersive X-ray analysis, and X-ray diffraction to determine the morphology and the phase structure of the electrodeposited film. It was found that the electrodeposited Pb-Sb-Te alloy thin film is a multiphase composition. The obtained data reveal that the most corrosion-resistant phase is the PbSb2Te4 alloy.

  19. Corrosion-resistant metallic coatings

    Directory of Open Access Journals (Sweden)

    F. Presuel-Moreno

    2008-10-01

    Full Text Available We describe recent computational and experimental studies on the corrosion properties of metallic coatings that can be tailored (tuned to deliver up to three corrosion-inhibiting functions to an underlying substrate. Attributes are tuned by a selection of alloy compositions and nanostructures, ideally in alloy systems that offer flexibility of choice to optimize the corrosion-resisting properties. An amorphous Al-based coating is tuned for corrosion protection by on-demand release of ionic inhibitors to protect defects in the coating, by formation of an optimized barrier to local corrosion in Cl− containing environments, as well as by sacrificial cathodic prevention. Further progress in this field could lead to the design of the next generation of adaptive or tunable coatings that inhibit corrosion of underlying substrates.

  20. Structure and mechanical properties of the three-layer material based on a vanadium alloy and corrosion-resistant steel

    Science.gov (United States)

    Nikulin, S. A.; Rozhnov, A. B.; Nechaikina, T. A.; Rogachev, S. O.; Zavodchikov, S. Yu.; Khatkevich, V. M.

    2014-10-01

    The quality of three-layer pipes has been studied; they are manufactured by hot pressing of a three-layer assembly of tubular billets followed by forging and cold rolling. The operating core is made from a V-4Ti-4Cr alloy. The protective claddings are made from corrosion-resistant steels of two grades, 08Kh17T and 20Kh13. The results of investigation into the structure and microhardness of the junction zone of steel and the vanadium alloy, which includes a contact zone and a transition diffusion layer, are reported. The 08Kh17T steel is shown to be a preferred cladding material.

  1. The fluoride coated AZ31B magnesium alloy improves corrosion resistance and stimulates bone formation in rabbit model.

    Science.gov (United States)

    Sun, Wei; Zhang, Guangdao; Tan, Lili; Yang, Ke; Ai, Hongjun

    2016-06-01

    This study aimed to evaluate the effect of fluorine coated Mg alloy and clarify its mechanism in bone formation. We implanted the fluorine coated AZ31B Mg alloy screw (group F) in rabbit mandibular and femur in vivo. Untreated AZ31B Mg alloy screw (group A) and titanium screw (group T) were used as control. Then, scanning electron microscopy, the spectral energy distribution analysis, hard and decalcified bone tissues staining were performed. Immunohistochemistry was employed to examine the protein expressions of bone morphogenetic protein 2 (BMP-2) and collagen type I in the vicinity of the implant. Compared with the group A, the degradation of the alloy was reduced, the rates of Mg corrosion and Mg ion release were slowed down, and the depositions of calcium and phosphate increased in the group F in the early stage of implantation. Histological results showed that fluorine coated Mg alloy had well osteogenic activity and biocompatibility. Moreover, fluoride coating obviously up-regulated the expressions of collagen type I and BMP-2. This study confirmed that the fluorine coating might improve the corrosion resistance of AZ31B Mg alloy and promote bone formation by up-regulated the expressions of collagen type I and BMP-2.

  2. Corrosion of high temperature resisting alloys exposed to heavy fuel ash; Corrosion de aleaciones resistentes a altas temperaturas expuestas a ceniza de combustoleo pesado

    Energy Technology Data Exchange (ETDEWEB)

    Wong Moreno, Adriana del Carmen

    1998-03-01

    The objective of the performed research was to study the degradation process by high temperature corrosion of alloys exposed to heavy fuel oil ashes through a comparative experimental evaluation of its performance that allowed to establish the mechanisms involved in the phenomenon. The experimentation carried out involved the determination of the resistance to the corrosion of 14 alloys of different type (low and medium alloy steels, ferritic and austenitic stainless steels, nickel base alloys and a FeCrAl alloy of type ODS) exposed to high temperatures (580 Celsius degrees - 900 Celsius degrees) in 15 ash deposits with different corrosive potential, which were collected in the high temperature zone of boilers of thermoelectric power stations. The later studies to the corrosion tests consisted of the analysis by sweeping electron microscopy supported by microanalysis of the corroded probes, with the purpose of determining the effect of Na, V and S on the corrosivity of the ash deposits and the effect of the main alloying elements on the corrosion resistance of the alloys. Such effects are widely documented to support the proposed mechanisms of degradation that are occurring. The global analysis of the generated results has allowed to propose a model to explain the global mechanism of corrosion of alloys exposed to the high temperatures of ash deposits. The proposed model, complements the processed one by Wilson, widely accepted for fused vanadates, as far as on one hand, it considers the effect of the sodium sulfate presence (in addition to the vanadium compounds) in the deposits, and on the other hand, it extends it to temperatures higher than the point of fusion of constituent vanadium compounds of the deposits. Both aspects involve considering the roll that the process of diffusion of species has on the degradation and the capacity of protection of the alloy. The research performed allowed to confirm what the Wilson model had established for deposits with high

  3. Study on the Correlation between Microstructure Corrosion and Wear Resistance of Ag-Cu-Ge Alloys

    Directory of Open Access Journals (Sweden)

    Antonio Cusma

    2015-03-01

    Full Text Available In this work, a morphological and structural characterization of a ternary Ag-Cu-Ge alloy of known composition was performed with the aim of evaluating how the passivation parameters (time and temperature influence the morphological features of the material surface. A nanomechanical characterization was performed in order to correlate the morphology and microstructure of the alloy with its tarnish, wear, and scratch resistance. It was found that the addition of germanium to the alloy not only provides the material with tarnish and fire-stain resistance, but it also improves the scratch and wear resistance owing to the formation of a dense and stable thin oxide layer.

  4. Mitigation of Corrosion on Magnesium Alloy by Predesigned Surface Corrosion

    Science.gov (United States)

    Zhang, Xuming; Wu, Guosong; Peng, Xiang; Li, Limin; Feng, Hongqing; Gao, Biao; Huo, Kaifu; Chu, Paul K.

    2015-11-01

    Rapid corrosion of magnesium alloys is undesirable in structural and biomedical applications and a general way to control corrosion is to form a surface barrier layer isolating the bulk materials from the external environment. Herein, based on the insights gained from the anticorrosion behavior of corrosion products, a special way to mitigate aqueous corrosion is described. The concept is based on pre-corrosion by a hydrothermal treatment of Al-enriched Mg alloys in water. A uniform surface composed of an inner compact layer and top Mg-Al layered double hydroxide (LDH) microsheet is produced on a large area using a one-step process and excellent corrosion resistance is achieved in saline solutions. Moreover, inspired by the super-hydrophobic phenomenon in nature such as the lotus leaves effect, the orientation of the top microsheet layer is tailored by adjusting the hydrothermal temperature, time, and pH to produce a water-repellent surface after modification with fluorinated silane. As a result of the trapped air pockets in the microstructure, the super-hydrophobic surface with the Cassie state shows better corrosion resistance in the immersion tests. The results reveal an economical and environmentally friendly means to control and use the pre-corrosion products on magnesium alloys.

  5. Electrodeposition of diamond-like carbon films on titanium alloy using organic liquids: Corrosion and wear resistance

    Energy Technology Data Exchange (ETDEWEB)

    Falcade, Tiago, E-mail: tiago.falcade@ufrgs.br [Federal University of Rio Grande do Sul, 9500 Bento Goncalves Ave. Sector 4, Building 75, 2nd floor, Porto Alegre, RS (Brazil); Shmitzhaus, Tobias Eduardo, E-mail: tobiasschmitzhaus@gmail.com [Federal University of Rio Grande do Sul, Porto Alegre, RS (Brazil); Gomes dos Reis, Otavio, E-mail: otavio_gomes214@hotmail.com [Federal University of Rio Grande do Sul, Porto Alegre, RS (Brazil); Vargas, Andre Luis Marin; Huebler, Roberto [Pontificia Universidade Catolica do Rio Grande do Sul (Brazil); Mueller, Iduvirges Lourdes, E-mail: ilmuller@ufrgs.br [Federal University of Rio Grande do Sul, Porto Alegre, RS (Brazil); Fraga Malfatti, Celia de, E-mail: celia.malfatti@ufrgs.br [Federal University of Rio Grande do Sul, Porto Alegre, RS (Brazil)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer The electrodeposition may be conducted at room temperature. Black-Right-Pointing-Pointer The DLC films have good resistance to corrosion in saline environments. Black-Right-Pointing-Pointer The films have lower coefficient of friction than the uncoated substrate. Black-Right-Pointing-Pointer The abrasive wear protection is evident in coated systems. - Abstract: Diamond-like carbon (DLC) films have been studied as coatings for corrosion protection and wear resistance because they have excellent chemical inertness in traditional corrosive environments, besides presenting a significant reduction in coefficient of friction. Diamond-like carbon (DLC) films obtained by electrochemical deposition techniques have attracted a lot of interest, regarding their potential in relation to the vapor phase deposition techniques. The electrochemical deposition techniques are carried out at room temperature and do not need vacuum system, making easier this way the technological transfer. At high electric fields, the organic molecules polarize and react on the electrode surface, forming carbon films. The aim of this work was to obtain DLC films onto Ti6Al4V substrate using as electrolyte: acetonitrile (ACN) and N,N-dimethylformamide (DMF). The films were characterized by atomic force microscopy (AFM), scanning electron microscopy (SEM), Raman spectroscopy, potentiodynamic polarization and wear tests. The results show that these films can improve, significantly, the corrosion resistance of titanium and its alloys and their wear resistance.

  6. Development of Advanced Wear and Corrosion Resistant Systems Through Laser Surface Alloying and Materials Simulations

    Energy Technology Data Exchange (ETDEWEB)

    R. P. Martukanitz and S. Babu

    2007-05-03

    Laser surfacing in the form of cladding, alloying, and modifications are gaining widespread use because of its ability to provide high deposition rates, low thermal distortion, and refined microstructure due to high solidification rates. Because of these advantages, laser surface alloying is considered a prime candidate for producing ultra-hard coatings through the establishment or in situ formation of composite structures. Therefore, a program was conducted by the Applied Research Laboratory, Pennsylvania State University and Oak Ridge National Laboratory to develop the scientific and engineering basis for performing laser-based surface modifications involving the addition of hard particles, such as carbides, borides, and nitrides, within a metallic matrix for improved wear, fatigue, creep, and corrosion resistance. This has involved the development of advanced laser processing and simulation techniques, along with the refinement and application of these techniques for predicting and selecting materials and processing parameters for the creation of new surfaces having improved properties over current coating technologies. This program has also resulted in the formulation of process and material simulation tools capable of examining the potential for the formation and retention of composite coatings and deposits produced using laser processing techniques, as well as positive laboratory demonstrations in producing these coatings. In conjunction with the process simulation techniques, the application of computational thermodynamic and kinetic models to design laser surface alloying materials was demonstrated and resulted in a vast improvement in the formulation of materials used for producing composite coatings. The methodology was used to identify materials and to selectively modify microstructures for increasing hardness of deposits produced by the laser surface alloying process. Computational thermodynamic calculations indicated that it was possible to induce the

  7. Effects of solution heat treatment on corrosion resistance of 5083F Al alloy

    Institute of Scientific and Technical Information of China (English)

    Seong-Jong KIM; Seok-Ki JANG

    2009-01-01

    Aluminum alloys are used as substitutes for fiber reinforced polymer(FRP) in ships and boats. However, ships constructed with 5000-series Al alloy suffer a little corrosion in the marine environment, when they run in high speed, and high flow rate, etc. Therefore, solution heat treatment was carried out to prevent corrosion. The optimal heat treatment involved heating specimens for 120 min at 420 ℃ and then cooling them in water. In addition, the optimal ageing condition involved ageing specimens for 240 min at 180 ℃. The slow strain rate test(SSRT) in a seawater revealed that heat treatment under optimal conditions produced improved elongation, time-to-fracture and amount of dimples compared with the as-received specimen.

  8. Effect of sintering processing on microstructure, mechanical properties and corrosion resistance of Ti–24Nb–4Zr–7.9Sn alloy for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Shibo, E-mail: guoshibo163@163.com [School of Electromechanism Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Chu, Aimin; Wu, Haijiang; Cai, Chunbo [School of Electromechanism Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); Qu, Xuanhui [State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2014-06-01

    Highlights: • Ti–24Nb–4Zr–7.9Sn alloy is prepared by powder metallurgy method. • The alloy prepared at 1250 °C for 2 h has more β-matrix and tiny α-precipitation. • The alloy prepared at 1250 °C for 2 h possesses good mechanical properties. • The alloy prepared at 1250 °C for 2 h exhibits better corrosion resistance. - Abstract: Ti–24Nb–4Zr–7.9Sn alloy was prepared by Powder Metallurgy (PM) method using titanium hydride powder, niobium powder, zirconium powder, and tin powder as raw materials. The effect of sintering processing on microstructure, mechanical properties, and corrosion resistance was investigated in details. The alloy possessed dominant β-matrix and a little α-precipitation. The mechanical properties of the alloy sintered at 1250 °C for 2 h were better than those of the alloys with other sintering processing, which would avoid stress shielding and thus prevent bone resorption in orthopedic implants applications. As long-term stability in biological environment is required, the electrochemical behaviors in a simulated body fluid (Hank’s solution and simulated saliva solution) were also evaluated. Potentiodynamic polarization curves exhibited that the sample sintered at 1250 °C for 2 h had better corrosion properties than those of other sintering processing. The good corrosion resistance combined with better mechanical biocompatibility made the Ti–24Nb–4Zr–7.9Sn alloy suitable for use as orthopedic implants.

  9. The effect of σ-phase precipitation at 800°C on the corrosion resistance in sea-water of a high alloyed duplex stainless steel

    NARCIS (Netherlands)

    Wilms, M.E.; Gadgil, V.J.; Krougman, J.M.; Ijsseling, F.P.

    1994-01-01

    Super-duplex stainless steels are recently developed high alloyed stainless steels that combine good mechanical properties with excellent corrosion resistance. Because of a high content of chromium and molybdenum, these alloys are susceptible to σ-phase precipitation during short exposure to

  10. Polarization-corrosion behavior of commercial gold- and silver-base casting alloys in Fusayama solution.

    Science.gov (United States)

    Johnson, D L; Rinne, V W; Bleich, L L

    1983-12-01

    Based on polarization measurements, high Au alloys are highly corrosion-resistant and exhibit the lowest corrosion rates; intermediate Au, Ag, and Pd alloys with Cu are passive but exhibit higher corrosion rates. Twenty weight percent (w/o) In-Ag alloys exhibit active corrosion behavior at potentials only 100 mV noble to the corrosion potential.

  11. Alloys For Flexible Hoses In A Corrosive Environment

    Science.gov (United States)

    Macdowell, Louis G., III; Ontiveros, Cordelia

    1992-01-01

    High-nickel alloy resists pitting corrosion. Report evaluates metal alloys for flexible hoses in corrosive environment. Tested to find alternatives to 304L stainless steel. Nineteen alloys selected for testing on basis of reputation for resistance to corrosion. Top five, in order of decreasing resistance to corrosion: Hastelloy(R) C-22, Inconel(R) 625, Hastelloy(R) C-276, Hastelloy(R) C-4, and Inco(R) alloy G-3. Of these, Hastelloy(R) C-22 found best for flexible-hose application.

  12. Microstructure and pitting corrosion resistance of AA2219 Al–Cu alloy friction stir welds – Effect of tool profile

    Directory of Open Access Journals (Sweden)

    Ch Venkata Rao

    2015-06-01

    Full Text Available AA2219 Al–Cu alloy is widely used in defence and aerospace applications due to required combination of high strength-to-weight ratio and toughness. Fabrication of components used for defence always involves welding. Even though the mechanical properties of the base metal are better, but the alloy suffers from poor mechanical and corrosion properties during fusion welding. To overcome the problems of fusion welding, friction stir welding (FSW is recognized as an alternative solid state joining method aimed to improve the mechanical and corrosion properties. Tool profile is one of the important variables which affect the performance of the friction stir weld. In the present work the effect of tool profile on the microstructure and pitting corrosion of AA2219 aluminium–copper alloy was studied. Electron backscattered diffraction results established that the grain size and orientation of weld nugget of triangle profile is finer than that of conical profile. Differential scanning calorimetric results show the evidence of precipitate dissolution during FSW. It was found that the microstructure changes, such as grain size and its orientation precipitate dissolution during FSW influence the hardness and corrosion behaviour. Pitting corrosion resistance of friction stir welds of AA2219 was found to be better for triangle profile tool compared to conical profile which is attributed to material flow and strengthening precipitate morphology in various zones. Higher amount of heat generation during FSW made using triangle profile tool may be the reason for greater dissolution of strengthening precipitates in nugget zone and coarsening in thermo mechanically affected zone (TMAZ and heat affected zone (HAZ.

  13. A Magnetic Properties and Corrosion Resistance of Fe-Si Alloy Coating Prepared on Mild Steel

    Directory of Open Access Journals (Sweden)

    Yi WANG

    2014-12-01

    Full Text Available The present work deals with preparation of Fe3Si coatings on mild steel and evaluation of its magnetic property and corrosion behavior. Magnetic property of coatings was measured using a vibrating sample magnetometer, the result shows that the saturation magnetization reached to the maximum value (214.1 emu•g-1 and the coercivity fell to the lowest (23.11 Oe in 1000oC. Corrosion behaviour of the coatings was studied using polarization in 3.5%NaCl solution. It was found that the corrosion current density (icorr decreased with increasing of heat treatment temperature up to 1000oC, indicating an improvement in corrosion resistance. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6446

  14. Micro-arc oxidization of a novel Mg–1Ca alloy in three alkaline KF electrolytes: Corrosion resistance and cytotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Z.J.; Li, M.; Liu, Q.; Xu, X.C. [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Cheng, Y., E-mail: chengyan@pku.edu.cn [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Zheng, Y.F. [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Department of Advanced Materials and Nanotechnology, College of Engineering, Peking University, Beijing 100871 (China); Xi, T.F. [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Wei, S.C. [Center for Biomedical Materials and Tissue Engineering, Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Department of Oral and Maxillofacial Surgery, School and Hospital of Stomatology, Peking University, Beijing 100871 (China)

    2014-02-15

    A newly-developed Mg–1Ca (wt%) alloy was treated by micro-arc oxidization (MAO) in KF-silicate- (Si coating), KF-phosphate- (P coating) and KF-silicate-phosphate (SiP coating) electrolytes. The microstructure, composition and corrosion resistance of the resultant MAO coatings were investigated using scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffractometry (XRD). Electrochemical analysis and immersion test in Hanks’ solution and MTT assay for in-vitro toxicity against MG63 cells were subsequently carried out. Results showed that all the three MAO coatings contributed to the improvement of corrosion resistance and cytocompatibility of substrate; however, P coating outperformed the two others due to its specific microstructure and composition.

  15. Mussel-inspired nano-multilayered coating on magnesium alloys for enhanced corrosion resistance and antibacterial property.

    Science.gov (United States)

    Wang, Bi; Zhao, Liang; Zhu, Weiwei; Fang, Liming; Ren, Fuzeng

    2017-09-01

    Magnesium alloys are promising candidates for load-bearing orthopedic implants due to their biodegradability and mechanical resemblance to natural bone tissue. However, the high degradation rate and the risk of implant-associated infections pose grand challenges for their clinical applications. Herein, we developed a nano-multilayered coating strategy through polydopamine and chitosan assisted layer-by-layer assembly of osteoinductive carbonated apatite and antibacterial sliver nanoparticles on the surface of AZ31 magnesium alloys. The fabricated nano-multilayered coating can not only obviously enhance the corrosion resistance but also significantly increase the antibacterial activity and demonstrate better biocompatility of magnesium alloys. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Characterization of the Resistance of Alloy 22 to Stress Corrosion Cracking

    Energy Technology Data Exchange (ETDEWEB)

    King, K J; Estill, J C; Rebak, R B

    2002-05-30

    In its current design, the high-level nuclear waste containers include an external layer of Alloy 22 (Ni-22Cr-13Mo-3W-3Fe). Since over their lifetime, the containers may be exposed to multi-ionic aqueous environments, a potential degradation mode of the outer layer could be environmentally assisted cracking (EAC). The objective of the current research was to characterize the effect of applied potential and temperature on the susceptibility of Alloy 22 to EAC in simulated concentrated water (SCW) using the slow strain rate test (SSRT). Results show that Alloy 22 may suffer EAC at applied potentials approximately 400 mV more anodic than the corrosion potential (E{sub corr}).

  17. Corrosion behavior of Ti–39Nb alloy for dentistry

    Energy Technology Data Exchange (ETDEWEB)

    Fojt, Jaroslav, E-mail: fojtj@vscht.cz [Institute of Chemical Technology, Technicka 5, 166 28 Prague (Czech Republic); Joska, Ludek [Institute of Chemical Technology, Technicka 5, 166 28 Prague (Czech Republic); Malek, Jaroslav [UJP Praha, Nad Kamínkou 1345, 156 10 Prague-Zbraslav (Czech Republic); Sefl, Vaclav [Institute of Chemical Technology, Technicka 5, 166 28 Prague (Czech Republic)

    2015-11-01

    To increase an orthopedic implant's lifetime, researchers are now concerned on the development of new titanium alloys with suitable mechanical properties (low elastic modulus–high fatigue strength), corrosion resistance and good workability. Corrosion resistance of the newly developed titanium alloys should be comparable with that of pure titanium. The effect of medical preparations containing fluoride ions represents a specific problem related to the use of titanium based materials in dentistry. The aim of this study was to determine the corrosion behavior of β titanium alloy Ti–39Nb in physiological saline solution and in physiological solution containing fluoride ions. Corrosion behavior was studied using standard electrochemical techniques and X-ray photoelectron spectroscopy. It was found that corrosion properties of the studied alloy were comparable with the properties of titanium grade 2. The passive layer was based on the oxides of titanium and niobium in several oxidation states. Alloying with niobium, which was the important part of the alloy passive layer, resulted in no significant changes of corrosion behavior. In the presence of fluoride ions, the corrosion resistance was higher than the resistance of titanium. - Highlights: • Alloy Ti–39Nb shows excellent corrosion resistance in physiological solution. • Corrosion resistance of Ti–39Nb alloy is significantly higher than that of titanium in the presence of fluoride ions. • The electrochemical impedance spectroscopy indicates a porous passive layer. • Passive layer of the alloy is enriched by niobium.

  18. Superelasticity, corrosion resistance and biocompatibility of the Ti–19Zr–10Nb–1Fe alloy

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Pengfei [School of Materials Science and Engineering, Beihang University, Beijing 100191 (China); Key Laboratory of Aerospace Materials and Performance (Ministry of Education), Beihang University, Beijing 100191 (China); Li, Yan, E-mail: liyan@buaa.edu.cn [School of Materials Science and Engineering, Beihang University, Beijing 100191 (China); Key Laboratory of Aerospace Materials and Performance (Ministry of Education), Beihang University, Beijing 100191 (China); Li, Kangming [School of Materials Science and Engineering, Beihang University, Beijing 100191 (China); Key Laboratory of Aerospace Materials and Performance (Ministry of Education), Beihang University, Beijing 100191 (China); Zhang, Deyuan [Life Tech Scientific Corporation, Shenzhen 518057 (China); Zhou, Chungen [School of Materials Science and Engineering, Beihang University, Beijing 100191 (China)

    2015-05-01

    Microstructure, mechanical properties, superelasticity and biocompatibility of a Ti–19Zr–10Nb–1Fe alloy are investigated. X-ray diffraction spectroscopy and transmission electron microscopy observations show that the as-cast Ti–19Zr–10Nb–1Fe alloy is composed of α′ and β phases, but only the β phase exists in the as-rolled and as-quenched alloys. The tensile stress–strain tests indicate that the as-quenched alloy exhibits a good combination of mechanical properties with a large elongation of 25%, a low Young's modulus of 59 GPa and a high ultimate tensile stress of 723 MPa. Superelastic recovery behavior is found in the as-quenched alloy during tensile tests, and the corresponding maximum of superelastic strain is 4.7% at the pre-strain of 6%. A superelastic recovery of 4% with high stability is achieved after 10 cyclic loading–unloading training processes. Potentiodynamic polarization and ion release measurements indicate that the as-quenched alloy shows a lower corrosion rate in Hank's solution and a much less ion release rate in 0.9% NaCl solution than those of the NiTi alloys. Cell culture results indicate that the osteoblasts' adhesion and proliferation are similar on both the Ti–19Zr–10Nb–1Fe and NiTi alloys. A better hemocompatibility is confirmed for the as-quenched Ti–19Zr–10Nb–1Fe alloy, attributed to more stable platelet adhesion and small activation degree, and a much lower hemolysis rate compared with the NiTi alloy. - Highlights: • A stable superelastic strain of 4.0% is achieved for the Ti–19Zr–10Nb–1Fe alloy. • The ion release rates of Ti–19Zr–10Nb–1Fe are much lower than that of Ni in NiTi. • Ti–19Zr–10Nb–1Fe has a similar cytocompatibility compared with the NiTi alloy. • Ti–19Zr–10Nb–1Fe exhibits a better hemocompatibility than the NiTi alloy.

  19. Heat Treatment and Properties of Nitrogen Alloyed, Martensitic,Corrosion-resistant Steels

    Institute of Scientific and Technical Information of China (English)

    Reinhold Schneider; Klaus Sammt; Roland Rabitsch; Michael Haspel

    2004-01-01

    This paper gives a short introduction to the typical process route and material properties of these steels in comparison to standard martensitic corrosion-resistant steels. The typical response of these steels to various heat treatment parameters is shown and explained using the three grades M333, N360 and M340 (all made by Bohler Edelstahl GmbH) as examples, and the physical metallurgy of these steels and its consequences for practical heat treatment is explained. The correlation between tempering parameters and their effect on the toughness and corrosion properties is explained in particular detail, showing that these new steels not only offer far better property combinations under the usual heat treatment parameters than standard martensitic corrosion-resistant steels, but that they also open the door to extending heat treatment combinations and properties.

  20. Thickness effects on corrosion and wear resistance properties of micro-arc discharge oxide coatings on AZ91D magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    HUANG Wei-jiu; LIU Ming; LI Zhao-feng; ZENG Rong-chang

    2006-01-01

    The microarc oxidation coatings with difference thickness were synthesized on AZ91D magnesium alloy. The microstructure and phase structure of the coatings were analyzed using SEM and XRD, the tribological properties and corrosion resistance behaviour of the coatings were also investigated. The results show that the coating contains two layers, a porous outer layer and relatively dense inner layer. The microhardness of the MAO coatings is four to six times higher than that of the magnesium alloy substrate. The MAO coatings have much better wear-resistance and corrosion resistance abilities than those of magnesium alloy substrate, but possess higher friction coefficient. The results further indicate that there is an optimization thickness for corrosion and wear resistance.

  1. Corrosion Resistance of Synergistic Welding Process of Aluminium Alloy 6061 T6 in Sea Water

    Directory of Open Access Journals (Sweden)

    Kharia Salman Hassan

    2014-12-01

    Full Text Available This work involves studying corrosion resistance of AA 6061T6 butt welded joints using Two different welding processes, tungsten inert gas (TIG and a solid state welding process known as friction stir welding, TIG welding process carried out by using Rolled sheet of thickness6mm to obtain a weld joint with dimension of (100, 50, 5 mm using ER4043 DE (Al Si5 as filler metal and argon as shielding gas, while Friction stir welding process carried out using CNC milling machine with a tool of rotational speed 1000 rpm and welding speed of 50mm/min to obtain the same butt joint dimensions. Also one of weld joint in the same dimensions subjected to synergistic weld process TIG and FSW weld process at the same previous weld conditions. All welded joints were tested by X-ray radiography and Faulty pieces were excluded. The joints without defects used to prepare many specimens for Corrosion test by the dimensions of (15*15*3 mm according to ASTM G71-31. Specimens subjected to micro hardness and microstructure test. Corrosion test was achieved by potential at scan rate( +1000 ,-1000mv/sec to estimate corrosion parameters by extrapolator Tafle method after polarized ±100 mv around open circuit potential,in seawater (3.5%NaCl at a temperature of 25°C. From result which obtained by Tafel equation. It was found that corrosion rate for TIG weld joint was higher than the others but synergistic weld process contributed in improving TIG corrosion resistance by a percentage of 14.3%. and FSW give the lest corrosion rate comparing with base metal.

  2. A comparative study of the cytotoxicity and corrosion resistance of nickel-titanium and titanium-niobium shape memory alloys.

    Science.gov (United States)

    McMahon, Rebecca E; Ma, Ji; Verkhoturov, Stanislav V; Munoz-Pinto, Dany; Karaman, Ibrahim; Rubitschek, Felix; Maier, Hans J; Hahn, Mariah S

    2012-07-01

    Nickel-titanium (NiTi) shape memory alloys (SMAs) are commonly used in a range of biomedical applications. However, concerns exist regarding their use in certain biomedical scenarios due to the known toxicity of Ni and conflicting reports of NiTi corrosion resistance, particularly under dynamic loading. Titanium-niobium (TiNb) SMAs have recently been proposed as an alternative to NiTi SMAs due to the biocompatibility of both constituents, the ability of both Ti and Nb to form protective surface oxides, and their superior workability. However, several properties critical to the use of TiNb SMAs in biomedical applications have not been systematically explored in comparison with NiTi SMAs. These properties include cytocompatibility, corrosion resistance, and alterations in alloy surface composition in response to prolonged exposure to physiological solutions. Therefore, the goal of the present work was to comparatively investigate these aspects of NiTi (49.2 at.% Ti) and TiNb (26 at.% Nb) SMAs. The results from the current studies indicate that TiNb SMAs are less cytotoxic than NiTi SMAs, at least under static culture conditions. This increased TiNb cytocompatibility was correlated with reduced ion release as well as with increased corrosion resistance according to potentio-dynamic tests. Measurements of the surface composition of samples exposed to cell culture medium further supported the reduced ion release observed from TiNb relative to NiTi SMAs. Alloy composition depth profiles also suggested the formation of calcium phosphate deposits within the surface oxide layers of medium-exposed NiTi but not of TiNb. Collectively, the present results indicate that TiNb SMAs may be promising alternatives to NiTi for certain biomedical applications. Copyright © 2012 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  3. SHOT PEENING INFLUENCE ON CORROSION RESISTANCE OF AE21 MAGNESIUM ALLOY

    OpenAIRE

    Branislav Hadzima; Michal Bukovina; Pavel Doležal

    2010-01-01

    Evaluation of the electrochemical characteristics of the AE21 magnesium alloy is presented in the article. The surfaces of tested alloys were treated by grinding and grinding followed by sodium bicarbonate shot-peening. The specimens were evaluated by electrochemical impedance spectroscopy method in combination with exposure tests in 0.1 NaCl solution. The exposition times were from 5 minutes to 168 hours. The measured data were analysed using equivalent circuits and polarization resistances ...

  4. Growth process and corrosion resistance of ceramic coatings of micro-arc oxidation on Mg-Gd-Y magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    王萍; 李建平; 郭永春; 杨忠

    2010-01-01

    The regulation of ceramic coating formed by micro-arc oxidation on Mg-11Gd-1Y-0.5Zn (wt.%) magnesium alloys was investigated by scanning electron microscopy (SEM) and X-ray diffractometer (XRD). The relation of phase structure and corrosion resistance of MgO coating formed by micro-arc oxidation in different growth stages was analyzed. The results showed that the growth of coating accorded with linear regularity in the initial stage of micro-arc oxidation, which was the stage of anodic oxidation controlled ...

  5. Electrochemical impedance spectroscopic investigation of the role of alkaline pre-treatment in corrosion resistance of a silane coating on magnesium alloy, ZE41

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty Banerjee, P. [Department of Chemical Engineering, Monash University, Clayton, VIC-3800 (Australia); CAST Cooperative Research Centre, Hawthorn, VIC-3122 (Australia); Singh Raman, R.K., E-mail: raman.singh@eng.monash.edu.a [Department of Chemical Engineering, Monash University, Clayton, VIC-3800 (Australia); Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC-3800 (Australia)

    2011-04-15

    The protective performance of the coatings of bis-1,2-(triethoxysilyl) ethane (BTSE) on ZE41 magnesium alloy with different surface pre-treatments were evaluated using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) in 0.1 M sodium chloride solution. Electrical equivalent circuits were developed based upon hypothetical corrosion mechanisms and simulated to correspond to the experimental data. The morphology and cross section of the alloy subjected to different pre-treatments and coatings were characterized using scanning electron microscope. A specific alkaline pre-treatment of the substrate prior to the coating has been found to improve the corrosion resistance of the alloy.

  6. The influence of Fe2+ concentration and deposition time on the corrosion resistance of the electrodeposited zinc–nickel–iron alloys

    Directory of Open Access Journals (Sweden)

    M.M. Abou-Krisha

    2016-11-01

    Full Text Available Electrodeposition operating conditions for Zn–Ni–Fe alloys from sulfate baths and the corrosion resistance of the electrodeposited alloys were studied. The comparison between Zn–Ni and Zn–Ni–Fe alloys co-deposition revealed that the remarkable inhibition of Ni and Fe deposition takes place due to the presence of Zn2+ in the plating bath. The electrodeposition was performed on the steel substrate, under galvanostatic conditions, for varying Fe2+ bath concentrations and at different times. X-ray diffraction studies of the deposit showed the presence of Fe3Ni2 phase and γ-phase with a composition of Ni2Zn11. The obtained data also exposed that the corrosion resistance increases as a result of increasing Fe2+ concentration and deposition time. Investigation was carried out using cyclic voltammetry and galvastatic techniques for electrodeposition, while linear polarization resistance and anodic linear sweeping voltammetry techniques were used for corrosion study.

  7. In vitro investigation of biodegradable polymeric coating for corrosion resistance of Mg-6Zn-Ca alloy in simulated body fluid

    Energy Technology Data Exchange (ETDEWEB)

    Gaur, Swati, E-mail: gaurswat@gmail.com [IITB–Monash Research Academy, IIT Bombay, Powai, Mumbai 400076 (India); Singh Raman, R.K. [Department of Mechanical, Monash University, Clayton, VIC-3800 (Australia); Department of Aerospace Engineering, Monash University, Clayton, VIC-3800 (Australia); Department of Chemical Engineering, Monash University, Clayton, VIC-3800 (Australia); Khanna, A.S. [Department of Metallurgical Engineering and Materials Science, IIT Bombay, Powai, Mumbai 400076 (India)

    2014-09-01

    A silane-based biodegradable coating was developed and investigated to improve corrosion resistance of an Mg-6Zn-Ca magnesium alloy to delay the biodegradation of the alloy in the physiological environment. Conditions were optimized to develop a stable and uniform hydroxide layer on the alloys surface—known to facilitate silane-substrate adhesion. A composite coating of two silanes, namely, diethylphosphatoethyltriethoxysilane (DEPETES) and bis-[3-(triethoxysilyl) propyl] tetrasulfide (BTESPT), was developed, by the sol-gel route. Corrosion resistance of the coated alloy was characterized in a modified-simulated body fluid (m-SBF), using potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The silane coating provided significant and durable corrosion resistance. During the course of this, hydrogen evolution and pH variation, if any, were monitored for both bare and coated alloys. The coating morphology was characterized using scanning electron microscopy (SEM) and energy dispersive X-ray analysis (EDAX) and the cross-linking in the coating was studied using Fourier transform infrared spectroscopy (FTIR). As indicated by X-ray diffraction (XRD) results, an important finding was the presence of hydrated magnesium phosphate on the sample that was subjected to immersion in m-SBF for 216 h. Magnesium phosphate is reported to support osteoblast formation and tissue healing. - Highlights: • A silane-based coating was investigated for improving corrosion resistance. • Coating was developed on Mg-6Zn-Ca alloy to delay its biodegradation in m-SBF. • Corrosion resistance was characterized, using polarization and EIS. • The coating morphology was characterized using SEM, EDAX, XRD and FTIR. • 1:4 volume ratio of DEPETES:BTESPT showed significant corrosion resistance.

  8. Considerations on the performance and fabrication of candidate materials for the Yucca Mountain repository waste packages highly corrosion resistant nickel-base and titanium-base alloys

    Energy Technology Data Exchange (ETDEWEB)

    Dalder, E; Goldberg, A

    1995-11-30

    Among the metallurgical factors that affect the performance of a material in a given environment are alloy composition, alloy segregation, depletion of alloying elements, non-uniform microstructures, precipitation leading to an increase in susceptibility to corrosion as well as decreases in ductility, residual plastic deformation, and residual stresses. Precipitation often occurs preferentially at grain boundaries, causing depletion of critical elements in regions adjacent to these boundaries. Continuous grain-boundary precipitates can lead to drops in ductility and toughness. The presence of non-metallic inclusions, if excessive and/or segregated, can also cause embrittlement. Segregation of alloying elements can result in localized galvanic action. Depletion of alloying elements as well as segregation can result in reductions in the concentrations of critical elements below those necessary to resist localized corrosion. Segregation and alloy depletion can also facilitate precipitation that could lead to embrittlement.

  9. Multifunctional substrate of Al alloy based on general hierarchical micro/nanostructures: superamphiphobicity and enhanced corrosion resistance

    Science.gov (United States)

    Li, Xuewu; Shi, Tian; Liu, Cong; Zhang, Qiaoxin; Huang, Xingjiu

    2016-01-01

    Aluminum alloys are vulnerable to penetrating and peeling failures in seawater and preparing a barrier coating to isolate the substrate from corrosive medium is an effective anticorrosion method. Inspired by the lotus leaves effect, a wetting alloy surface with enhanced anticorrosion behavior has been prepared via etch, deposition, and low-surface-energy modification. Results indicate that excellent superamphiphobicity has been achieved after the modification of the constructed hierarchical labyrinth-like microstructures and dendritic nanostructures. The as-prepared surface is also found with good chemical stability and mechanical durability. Furthermore, superior anticorrosion behaviors of the resultant samples in seawater are investigated by electrochemical measurements. Due to trapped air in micro/nanostructures, the newly presented solid-air-liquid contacting interface can help to resist the seawater penetration by greatly reducing the interface interaction between corrosive ions and the superamphiphobic surface. Finally, an optimized two-layer perceptron artificial neural network is set up to model and predict the cause-and-effect relationship between preparation conditions and the anticorrosion parameters. This work provides a great potential to extend the applications of aluminum alloys especially in marine engineering fields. PMID:27775053

  10. The addition of Si to the Ti–35Nb alloy and its effect on the corrosion resistance, when applied to biomedical materials

    Energy Technology Data Exchange (ETDEWEB)

    Tavares, A.M.G.; Fernandes, B.S.; Souza, S.A.; Batista, W.W.; Cunha, F.G.C. [Department of Materials Science and Engineering, Federal University of Sergipe, 49100-000 São Cristóvão, SE (Brazil); Landers, R. [Institute of Physics Gleb Wataghin, State University of Campinas – UNICAMP, 13083-859 Campinas, SP (Brazil); Macedo, M.C.S.S., E-mail: michellecardinales@gmail.com [Department of Materials Science and Engineering, Federal University of Sergipe, 49100-000 São Cristóvão, SE (Brazil)

    2014-04-05

    Highlights: • An investigation of the corrosion resistance of Ti–Nb–Si was proposed. • The study was based on polarization curves, OCP, electrochemical impedance, XPS. • The addition of Si to 0.35% increased the corrosion resistance of the alloys. • Data suggest that the studied alloys are promising for biomedical applications. -- Abstract: Alloy elements such as niobium and silicon have been added to titanium as an alternative for new materials to be used in orthopedic implants once they present biocompatibility and favor reductions in the elastic modulus. However, these new materials’ behavior, in face of corrosion is still demanding careful investigations because they will be subjected to an aggressive environ, such as the human body. The corrosion resistance of the Ti–35Nb–(0; 0.15; 0.35; 0.55)Si (% in mass) when in physiological medium was assessed by means of polarization curves, open circuit potential and electrochemical impedance spectroscopy. The compositions of the passive films were analyzed by X-ray photoelectron spectroscopy (XPS). Outcomes show that the alloys presented good rapid repassivation capacity after film breaking under high potentials. The high values of resistance to polarization – Rp – pinpoint that the formed oxide films are resistive. They work as a protecting barrier against aggressive ions. Data suggest that the studied alloys are promising for orthopedic implant applications.

  11. Laser surface alloying of FeCoCrAlNi high-entropy alloy on 304 stainless steel to enhance corrosion and cavitation erosion resistance

    Science.gov (United States)

    Zhang, S.; Wu, C. L.; Zhang, C. H.; Guan, M.; Tan, J. Z.

    2016-10-01

    FeCoCrAlNi high-entropy alloy coating was synthesized with premixed high-purity Co, Cr, Al and Ni powders on 304 stainless steel by laser surface alloying, aiming at improving corrosion and cavitation erosion resistance. Phase constituents, microstructure and microhardness were investigated using XRD, SEM, and microhardness tester, respectively. The cavitation erosion and electrochemical corrosion behavior of FeCoCrAlNi coating in 3.5% NaCl solution were also evaluated using an ultrasonic vibrator and potentiodynamic polarization measurement. Experimental results showed that with appropriate laser processing parameters, FeCoCrAlNi coating with good metallurgical bonding to the substrate could be achieved. FeCoCrAlNi coating was composed of a single BCC solid solution. The formation of simple solid solutions in HEAs was the combined effect of mixing entropy (ΔSmix), mixing enthalpy (ΔHmix), atom-size difference (δ) and valence electron concentration (VEC), and the effect of ΔSmix was much larger than that of the other factors. The microhardness of the FeCoCrAlNi coating was ~3 times that of the 304 stainless steel. Both the corrosion and cavitation erosion resistance of the coating were improved. The cavitation erosion resistance for FeCoCrAlNi HEA coating was ~7.6 times that of 304 stainless steel. The corrosion resistance was also improved as reflected by a reduction in the current density of one order of magnitude as compared with 304 stainless steel.

  12. Microstructure, corrosion resistance and cytocompatibility of Mg-5Y-4Rare Earth-0.5Zr (WE54) alloy

    Energy Technology Data Exchange (ETDEWEB)

    Smola, Bohumil, E-mail: bohumil.smola@mff.cuni.cz [Charles University Prague, Faculty of Mathematics and Physics, Ke Karlovu 5, 121 16 Praha 2 (Czech Republic); Joska, Ludek [Institute of Chemical Technology Prague, Faculty of Chemical Technology, Technicka 5, 166 28 Praha 6 (Czech Republic); Brezina, Vitezslav [University of South Bohemia, Institute of Physical Biology, Zamek 136, 373 33 Nove Hrady (Czech Republic); Stulikova, Ivana [Charles University Prague, Faculty of Mathematics and Physics, Ke Karlovu 5, 121 16 Praha 2 (Czech Republic); Hnilica, Frantisek [Czech Technical University in Prague, Faculty of Mechanical Engineering, Karlovo namesti 13, 121 35 Praha 2 (Czech Republic)

    2012-05-01

    Conventionally cast Mg-5Y-4Rare Earth-0.5Zr alloy (WE54) was solution treated (525 Degree-Sign C/8 h - T4) and one part subsequently aged (200 Degree-Sign C/16 h - T6). Powder from the cast WE54 alloy prepared by gas atomizing was consolidated by extrusion at 250 Degree-Sign C or 400 Degree-Sign C. Dense triangular arrangement of prismatic plates of transient D0{sub 19} and C-base centered orthorhombic phases precipitated in the {alpha}-Mg matrix during the T6 treatment. Both alloys prepared by powder metallurgy exhibit similar microstructure consisting of {approx} 4-6 {mu}m {alpha}-Mg matrix fibers surrounded by particles of the equilibrium Mg{sub 5}(Y, Nd) phase and of oxides. Open circuit potential and polarization resistance in the isotonic saline (9 g/l NaCl/H{sub 2}O) were monitored for 24 h. The corrosion rate of the T4 and T6 treated alloys was about 80 times lower than that of commercial Mg. Both alloys prepared by powder metallurgy exhibited approximately 8 times higher corrosion resistance than commercial Mg. The human MG-63 osteoblast-like cells spreading and division in the extracts (0.28 g in 28 ml of EMEM) of all 4 alloys were monitored by cinemicrography for 24 h. The MG-63 cells proliferate without cytotoxicity in all extracts. - Highlights: Black-Right-Pointing-Pointer T6 treated WE54 alloy exhibit dense triangular arrangement of {beta} Double-Prime and {beta} Prime phase prismatic plates. Black-Right-Pointing-Pointer Microstructure of PM prepared WE54 alloy consists of {alpha}-Mg phase cells surrounded by {beta} phase particles. Black-Right-Pointing-Pointer PM produced WE54 corroded 10 times faster in physiological solution thanT4 and T6 treated WE54. Black-Right-Pointing-Pointer MG63 cell spreading in EMEM extracts of PM prepared WE54 is comparable to that in control EMEM. Black-Right-Pointing-Pointer Cell mitosis is enhanced in PM WE54 extracts compared to the control and extracts of T4 and T6 WE54.

  13. Corrosion Behavior of Au, Hastelloy C-276 Alloy and Monel 400 Alloy in Molten Lithium Fluoride

    Institute of Scientific and Technical Information of China (English)

    WANG; Chang-shui; GUO; Jun-kang

    2013-01-01

    For searching better corrosion-resistant material in high temperature,we investigated the corrosion behavior of Au,Haynes C-276 alloy and Monel 400 alloy in molten lithium fluoride at 950℃.The corrosion products and fine structures of the corroded specimens were characterized by inductively coupled plasma mass spectrometry(ICP-MS),scanning electron microscope(SEM),energy dispersive

  14. Finding of Gray Points on the Surface of the Sn-Fe Alloy Layer and Its Effects on the Corrosion Resistance of the Alloy Layer

    Institute of Scientific and Technical Information of China (English)

    2003-01-01

    After removing tin coating of tinplates offered by some steel works, we discovered massive, highly disperse gray points outspreading along rolling direction on the surface of the alloy layer. Morphology of the alloy layer was observed by scanning electron microscope (SEM), and many cavities of the alloy layer were found out in the gray point. After analyzing the composition of the alloy layer, we found that content of Fe in the gray points was more than that in the normal alloy layer. Moreover, corrosion resistance of the alloy layer declines with increase of amount of gray points.In addition, the hot-humidity testing was carried out for some plates whose surface has many gray points. After 14 days, there were many rust points occurring in the edge of gray points and in the small gray points. The morphology of rust points was observed by atomic force microscope (AFM). The reason why rust points generated in the edge of gray points and in the small gray points was discussed.

  15. Alloys For Corrosive, Hydrogen-Rich Environments

    Science.gov (United States)

    Mcpherson, William B.; Bhat, Biliyar N.; Chen, Po-Shou; Kuruvilla, A. K.; Panda, Binayak

    1993-01-01

    "NASA-23" denotes class of alloys resisting both embrittlement by hydrogen and corrosion. Weldable and castable and formed by such standard processes as rolling, forging, and wire drawing. Heat-treated to obtain desired combinations of strength and ductility in ranges of 100 to 180 kpsi yield strength, 120 to 200 kpsi ultimate tensile strength, and 10 to 30 percent elongation at break. Used in place of most common aerospace structural alloy, Inconel(R) 718.

  16. Method for inhibiting corrosion of nickel-containing alloys

    Science.gov (United States)

    DeVan, J.H.; Selle, J.E.

    Nickel-containing alloys are protected against corrosion by contacting the alloy with a molten alkali metal having dissolved therein aluminum, silicon or manganese to cause the formation of a corrosion-resistant intermetallic layer. Components can be protected by applying the coating after an apparatus is assembled.

  17. One-step electrodeposition process to fabricate corrosion-resistant superhydrophobic surface on magnesium alloy.

    Science.gov (United States)

    Liu, Qin; Chen, Dexin; Kang, Zhixin

    2015-01-28

    A simple, one-step method has been developed to construct a superhydrophobic surface by electrodepositing Mg-Mn-Ce magnesium plate in an ethanol solution containing cerium nitrate hexahydrate and myristic acid. Scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectroscopy were employed to characterize the surfaces. The shortest electrodeposition time to obtain a superhydrophobic surface was about 1 min, and the as-prepared superhydrophobic surfaces had a maximum contact angle of 159.8° and a sliding angle of less than 2°. Potentiodynamic polarization and electrochemical impedance spectroscopy measurements demonstrated that the superhydrophobic surface greatly improved the corrosion properties of magnesium alloy in 3.5 wt % aqueous solutions of NaCl, Na2SO4, NaClO3, and NaNO3. Besides, the chemical stability and mechanical durability of the as-prepared superhydrophobic surface were also examined. The presented method is rapid, low-cost, and environmentally friendly and thus should be of significant value for the industrial fabrication of anticorrosive superhydrophobic surfaces and should have a promising future in expanding the applications of magnesium alloys.

  18. Materials Reliability Program Resistance to Primary Water Stress Corrosion Cracking of Alloys 690, 52, and 152 in Pressurized Water Reactors (MRP-111)

    Energy Technology Data Exchange (ETDEWEB)

    Xu, H. [Framatome ANP, Inc., Lynchburg, VA (United States); Fyfitch, S. [Framatome ANP, Inc., Lynchburg, VA (United States); Scott, P. [Framatome ANP, SAS, Paris (France); Foucault, M. [Framatome ANP, SAS, Le Creusot (France); Kilian, R. [Framatome ANP, GmbH, Erlangen (Germany); Winters, M. [Framatome ANP, GmbH, Erlangen (Germany)

    2004-03-01

    Over the last thirty years, stress corrosion cracking in PWR primary water (PWSCC) has been observed in numerous Alloy 600 component items and associated welds, sometimes after relatively long incubation times. Repairs and replacements have generally utilized wrought Alloy 690 material and its compatible weld metals (Alloy 152 and Alloy 52), which have been shown to be very highly resistant to PWSCC in laboratory experiments and have been free from cracking in operating reactors over periods already up to nearly 15 years. It is nevertheless prudent for the PWR industry to attempt to quantify the longevity of these materials with respect to aging degradation by corrosion in order to provide a sound technical basis for the development of future inspection requirements for repaired or replaced component items. This document first reviews numerous laboratory tests, conducted over the last two decades, that were performed with wrought Alloy 690 and Alloy 52 or Alloy 152 weld materials under various test conditions pertinent to corrosion resistance in PWR environments. The main focus of the present review is on PWSCC, but secondary-side conditions are also briefly considered.

  19. Comparison of Super-Hydrophobicity and Corrosion Resistance of Micro-Nano Structured Nickel and Nickel- Cobalt Alloy Coatings on Copper Substrate

    Directory of Open Access Journals (Sweden)

    S. Khorsand

    2016-03-01

    Full Text Available Super-hydrophobic nickel and nickel-cobalt alloy coatings with micro-nano structure were successfully electrodeposited on copper substrates with one and two steps electrodeposition. Surface morphology, wettability and corrosion  resistance were characterized by scanning electron microscopy, water contact angle measurements, electrochemical impedanc spectroscopy (EIS and potentiodynamic polarization curves. The results showed that the wettability of the micro-nano Ni and Ni-Co films varied from super-hydrophilicity to super-hydrophobicity by exposure of the surface to air at room temperature. The corrosion results revealed the positive effect of hydrophobicity on corrosion resistance of Ni coating (~10 times and Ni-Co coating (~100 times in comparison with their fresh coatings. The results showed that super-hydrophobic nickel coating had higher corrosion resistance than super-hydrophobic nickel-cobalt coating.

  20. Effect of surface roughness on leakage current and corrosion resistance of oxide layer on AZ91 Mg alloy prepared by plasma electrolytic oxidation

    Science.gov (United States)

    Yoo, Bongyoung; Shin, Ki Ryoung; Hwang, Duck Young; Lee, Dong Heon; Shin, Dong Hyuk

    2010-09-01

    The influence of the surface roughness of Mg alloys on the electrical properties and corrosion resistance of oxide layers obtained by plasma electrolytic oxidation (PEO) were studied. The leakage current in the insulating oxide layer was enhanced by increasing the surface roughness, which is a favorable characteristic for the material when applied to hand-held electronic devices. The variation of corrosion resistance with surface roughness was also investigated. The corrosion resistance was degraded by the increasing surface roughness, which was confirmed with DC polarization and impedance spectroscopy. Pitting corrosion on the passive oxide layer was also analyzed with a salt spray test, which showed that the number of pits was not affected by the surface roughness when the spray time reached 96 h.

  1. Corrosion resistance of Zn-Al layered double hydroxide/poly(lactic acid) composite coating on magnesium alloy AZ31

    Science.gov (United States)

    Zeng, Rong-Chang; Li, Xiao-Ting; Liu, Zhen-Guo; Zhang, Fen; Li, Shuo-Qi; Cui, Hong-Zhi

    2015-12-01

    A Zn-Al layered double hydroxide (ZnAl-LDH) coating consisted of uniform hexagonal nano-plates was firstly synthesized by co-precipitation and hydrothermal treatment on the AZ31 alloy, and then a poly(lactic acid) (PLA) coating was sealed on the top layer of the ZnAl-LDH coating using vacuum freeze-drying. The characteristics of the ZnAl-LDH/PLA composite coatings were investigated by means of XRD, SEM, FTIR and EDS. The corrosion resistance of the coatings was assessed by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). The results showed that the ZnAl-LDH coating contained a compact inner layer and a porous outer layer, and the PLA coating with a strong adhesion to the porous outer layer can prolong the service life of the ZnAl-LDH coating. The excellent corrosion resistance of this composite coating can be attributable to its barrier function, ion-exchange and self-healing ability.

  2. Coatings for improved corrosion resistance

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.

    1992-05-01

    Several coating approaches are being developed to resist attack in coal-fired environments and thereby minimize corrosion of underlying substrate alloys and extend the time for onset of breakaway corrosion. In general, coating systems can be classified as either diffusion or overlay type, which are distinguished principally by the method of deposition and the structure of the resultant coating-substrate bond. The coating techniques examined are pack cementation, electrospark deposition, physical and chemical vapor deposition, plasma spray, and ion implantation. In addition, ceramic coatings are used in some applications.

  3. Hardface coating systems and methods for metal alloys and other materials for wear and corrosion resistant applications

    Energy Technology Data Exchange (ETDEWEB)

    Seals, Roland D.

    2015-08-18

    The present disclosure relates generally to hardface coating systems and methods for metal alloys and other materials for wear and corrosion resistant applications. More specifically, the present disclosure relates to hardface coatings that include a network of titanium monoboride (TiB) needles or whiskers in a matrix, which are formed from titanium (Ti) and titanium diboride (TiB.sub.2) precursors by reactions enabled by the inherent energy provided by the process heat associated with coating deposition and, optionally, coating post-heat treatment. These hardface coatings are pyrophoric, thereby generating further reaction energy internally, and may be applied in a functionally graded manner. The hardface coatings may be deposited in the presence of a number of fluxing agents, beta stabilizers, densification aids, diffusional aids, and multimode particle size distributions to further enhance their performance characteristics.

  4. The Effect of Silane on the Microstructure, Corrosion, and Abrasion Resistances of the Anodic Films on Ti Alloy

    Science.gov (United States)

    Wang, Jinwei; Chen, Jiali

    2016-04-01

    Anodic oxide films on Ti-6Al-4V alloy are prepared using sodium hydroxide as the base electrolyte containing aminopropyl trimethoxysilane (APS) as an additive. Some APS undergo hydrolysis, adsorption, and chemical reaction with the TiO x to form Ti-O-Si bond as confirmed by ATR-FTIR and XPS spectra, and in turn their surface appearance and roughness are greatly changed with the addition of APS as observed by their SEM images. These amino anodic films possess much higher corrosive resistances since the formation of Ti-O-Si complex enhances the compactness of the anodic films and the existence of aminopropyl groups inside the pores provides additional blocking effects. Besides, their improvement in anti-abrasive capability is attributed to the toughening effect of the chemically bonded silanes and the lubrication functions from both the chemically bonded and physically absorbed silanes between the touched interfaces.

  5. Preliminary study on the corrosion resistance, antibacterial activity and cytotoxicity of selective-laser-melted Ti6Al4V-xCu alloys.

    Science.gov (United States)

    Guo, Sai; Lu, Yanjin; Wu, Songquan; Liu, Lingling; He, Mengjiao; Zhao, Chaoqian; Gan, Yiliang; Lin, Junjie; Luo, Jiasi; Xu, Xiongcheng; Lin, Jinxin

    2017-03-01

    In this study, a series of Cu-bearing Ti6Al4V-xCu (x=0, 2, 4, 6wt%) alloys (shorten by Ti6Al4V, 2C, 4C, and 6C, respectively.) with antibacterial function were successfully fabricated by selective laser melting (SLM) technology with mixed spherical powders of Cu and Ti6Al4V for the first time. In order to systematically investigate the effects of Cu content on the microstructure, phase constitution, corrosion resistance, antibacterial properties and cytotoxicity of SLMed Ti6Al4V-xCu alloys, experiments including XRD, SEM-EDS, electrochemical measurements, antibacterial tests and cytotoxicity tests were conducted with comparison to SLMed Ti6Al4V alloy (Ti6Al4V). Microstructural observations revealed that Cu had completely fused into the Ti6Al4V alloy, and presented in the form of Ti2Cu phase at ambient temperature. With Cu content increase, the density of the alloy gradually decreased, and micropores were obviously found in the alloy. Electrochemical measurements showed that corrosion resistance of Cu-bearing alloys were stronger than Cu-free alloy. Antibacterial tests demonstrated that 4C and 6C alloys presented strong and stable antibacterial property against Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus) compared to the Ti6Al4V and 2C alloy. In addition, similar to the Ti6Al4V alloy, the Cu-bearing alloys also exerted good cytocompatibility to the Bone Marrow Stromal Cells (BMSCs) from Sprague Dawley (SD) rats. Based on those results, the preliminary study verified that it was feasible to fabricated antibacterial Ti6Al4V-xCu alloys direct by SLM processing mixed commercial Ti6Al4V and Cu powder.

  6. An Industrial Perspective on Environmentally Assisted Cracking of Some Commercially Used Carbon Steels and Corrosion-Resistant Alloys

    Science.gov (United States)

    Ashida, Yugo; Daigo, Yuzo; Sugahara, Katsuo

    2017-08-01

    Commercial metals and alloys like carbon steels, stainless steels, and nickel-based super alloys frequently encounter the problem of environmentally assisted cracking (EAC) and resulting failure in engineering components. This article aims to provide a perspective on three critical industrial applications having EAC issues: (1) corrosion and cracking of carbon steels in automotive applications, (2) EAC of iron- and nickel-based alloys in salt production and processing, and (3) EAC of iron- and nickel-based alloys in supercritical water. The review focuses on current industrial-level understanding with respect to corrosion fatigue, hydrogen-assisted cracking, or stress corrosion cracking, as well as the dominant factors affecting crack initiation and propagation. Furthermore, some ongoing industrial studies and directions of future research are also discussed.

  7. Surface modification for corrosion resistance

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.

    1993-06-01

    The raw gas environments that arise from coal gasification have chemical compositions that are low in pO{sub 2} and moderate-to-high in pS{sub 2}. Metallic materials for service in such an environment undergo predominantly sulfidation attack at temperatures of 400 to 700{degree}C. Modification of alloy compositions in bulk can alter the scaling processes and lead to improvements in corrosion resistance, but the benefits can only be attained at temperatures much higher than the service temperatures of the components. Modification of surfaces of structural components by several of the coating techniques examined in this study showed substantial benefit in corrosion resistance when tested in simulated coal gasification environments. The paper presents several examples of surface modification and their corrosion performance.

  8. Mitigation of Corrosion on Magnesium Alloy by Predesigned Surface Corrosion

    OpenAIRE

    Xuming Zhang; Guosong Wu; Xiang Peng; Limin Li; Hongqing Feng; Biao Gao; Kaifu Huo; Chu, Paul K.

    2015-01-01

    Rapid corrosion of magnesium alloys is undesirable in structural and biomedical applications and a general way to control corrosion is to form a surface barrier layer isolating the bulk materials from the external environment. Herein, based on the insights gained from the anticorrosion behavior of corrosion products, a special way to mitigate aqueous corrosion is described. The concept is based on pre-corrosion by a hydrothermal treatment of Al-enriched Mg alloys in water. A uniform surface c...

  9. High performance corrosion and wear resistant composite titanium nitride layers produced on the AZ91D magnesium alloy by a hybrid method

    Directory of Open Access Journals (Sweden)

    Michał Tacikowski

    2014-09-01

    Full Text Available Composite, diffusive titanium nitride layers formed on a titanium and aluminum sub-layer were produced on the AZ91D magnesium alloy. The layers were obtained using a hybrid method which combined the PVD processes with the final sealing by a hydrothermal treatment. The microstructure, resistance to corrosion, mechanical damage, and frictional wear of the layers were examined. The properties of the AZ91D alloy covered with these layers were compared with those of the untreated alloy and of some engineering materials such as 316L stainless steel, 100Cr6 bearing steel, and the AZ91D alloy subjected to commercial anodizing. It has been found that the composite diffusive nitride layer produced on the AZ91D alloy and then sealed by the hydrothermal treatment ensures the corrosion resistance comparable with that of 316L stainless steel. The layers are characterized by higher electrochemical durability which is due to the surface being overbuilt with the titanium oxides formed, as shown by the XPS examinations, from titanium nitride during the hydrothermal treatment. The composite titanium nitride layers exhibit high resistance to mechanical damage and wear, including frictional wear which is comparable with that of 100Cr6 bearing steel. The performance properties of the AZ91D magnesium alloy covered with the composite titanium nitride coating are substantially superior to those of the alloy subjected to commercial anodizing which is the dominant technique employed in industrial practice.

  10. Corrosion of magnesium alloys in commercial engine coolants

    Energy Technology Data Exchange (ETDEWEB)

    Song, G.; StJohn, D.H. [CRC for Cast Metals Manufacturing (CAST), Division of Materials, School of Engineering, The University of Queensland, Brisbane, QLD 4072 (Australia)

    2005-01-01

    A number of magnesium alloys show promise as engine block materials. However, a critical issue for the automotive industry is corrosion of the engine block by the coolant and this could limit the use of magnesium engine blocks. This work assesses the corrosion performance of conventional magnesium alloy AZ91D and a recently developed engine block magnesium alloy AM-SC1 in several commercial coolants. Immersion testing, hydrogen evolution measurement, galvanic current monitoring and the standard ASTM D1384 test were employed to reveal the corrosion performance of the magnesium alloys subjected to the coolants. The results show that the tested commercial coolants are corrosive to the magnesium alloys in terms of general and galvanic corrosion. The two magnesium alloys exhibited slightly different corrosion resistance to the coolants with AZ91D being more corrosion resistant than AM-SC1. The corrosivity varied from coolant to coolant. Generally speaking, an organic-acid based long life coolant was less corrosive to the magnesium alloys than a traditional coolant. Among the studied commercial coolants, Toyota long life coolant appeared to be the most promising one. In addition, it was found that potassium fluoride effectively inhibited corrosion of the magnesium alloys in the studied commercial coolants. Both general and galvanic corrosion rates were significantly decreased by addition of KF, and there were no evident side effects on the other engine block materials, such as copper, solder, brass, steel and aluminium alloys, in terms of their corrosion performance. The ASTM D 1384 test further confirmed these results and suggested that Toyota long life coolant with 1%wt KF addition is a promising coolant for magnesium engine blocks. (Abstract Copyright [2005], Wiley Periodicals, Inc.)

  11. Crystallization and Corrosion Resistance in Different Aqueous Solutions of Zr50.7Ni28Cu9Al12.3 Amorphous Alloy and Its Crystallization Counterparts

    Science.gov (United States)

    Ge, Wenjuan; Li, Boyu; Axinte, Eugen; Zhang, Zitang; Shang, Caiyun; Wang, Yan

    2017-02-01

    The Zr50.7Ni28Cu9Al12.3 amorphous alloy and its crystallization counterparts have been prepared using a melt spinning technique and proper annealing treatment. The as-annealed products at 768 K are amorphous composites consisting of a main amorphous phase and a few ZrO2 nanocrystals. The corrosion behaviors have been investigated in 0.5-M NaCl, 1-M HCl, and 0.5-M H2SO4 solutions. The results show that amorphous composites present the enhanced corrosion resistance in Cl- containing solutions due to the formation of compact passive films, which are promoted by an appropriate quantity of ZrO2 nanocrystals. Nevertheless, the relaxed samples possess good corrosion resistance in H2SO4 solution, which is attributed to the existence of Zr(Al, Ni)-rich protective film induced by the depletion of Cu. In addition, corrosion resistance of the tested alloys is relatively superior in H2SO4 solution, especially for pitting corrosion resistance, and inferior in HCl solution.

  12. Corrosion Protection of AM50 Magnesium Alloy by Nafion/DMSO Organic Coatings

    Institute of Scientific and Technical Information of China (English)

    SONG Renguo; ZHENG Xiaohua; BAI Shuju; BLAWERT Carsten; DIETZEL Wolfgang

    2008-01-01

    The effectiveness of the corrosion protection of Nafion/Dimethysulfoxid (DMSO) organic coatings for AM50 magnesium alloy prepared by simple immersion and heat treatment was investigated. Its corrosion resistance and morphologies of the Nafion/DMSO organic coatings were studied by electrochemical corrosion testing and optical microscopy. The results show that Nafion/DMSO organic coatings can improve the corrosion resistance of AM50 magnesium alloy effectively. Also, the corrosion resistance increases with the surface density of the organic coatings.

  13. Improved Stress Corrosion Cracking Resistance and Strength of a Two-Step Aged Al-Zn-Mg-Cu Alloy Using Taguchi Method

    Science.gov (United States)

    Lin, Lianghua; Liu, Zhiyi; Ying, Puyou; Liu, Meng

    2015-12-01

    Multi-step heat treatment effectively enhances the stress corrosion cracking (SCC) resistance but usually degrades the mechanical properties of Al-Zn-Mg-Cu alloys. With the aim to enhance SCC resistance as well as strength of Al-Zn-Mg-Cu alloys, we have optimized the process parameters during two-step aging of Al-6.1Zn-2.8Mg-1.9Cu alloy by Taguchi's L9 orthogonal array. In this work, analysis of variance (ANOVA) was performed to find out the significant heat treatment parameters. The slow strain rate testing combined with scanning electron microscope and transmission electron microscope was employed to study the SCC behaviors of Al-Zn-Mg-Cu alloy. Results showed that the contour map produced by ANOVA offered a reliable reference for selection of optimum heat treatment parameters. By using this method, a desired combination of mechanical performances and SCC resistance was obtained.

  14. Corrosion Resistance ofAA6063-TypeAl-Mg-SiAlloy by Silicon Carbide in Sodium Chloride Solution for MarineApplication

    Institute of Scientific and Technical Information of China (English)

    Ojo Sunday Isaac Fayomi; Malik Abdulwahab; Ferdinand Asuke

    2015-01-01

    The present work focused on corrosion inhibition of AA6063 type Al-Mg-Si alloy in sodium chloride (NaCl) solution with a silicon carbide inhibitor, using the potentiodynamic electrochemical method. The aluminium alloy surface morphology was examined, in the as-received and as-corroded in the un-inhibited state, with scanning electron microscopy equipped with energy dispersive spectroscopy (SEM-EDS). The results obtained via linear polarization indicated a high corrosion potential for the unprotected as-received alloy. Equally, inhibition efficiency as high as 98.82% at 10.0 g/v silicon carbide addition was obtained with increased polarization resistance (Rp), while the current density reduced significantly for inhibited samples compared to the un-inhibited aluminium alloy. The adsorption mechanism of the inhibitor aluminium alloy follows the Langmuir adsorption isotherm. This shows that the corrosion rate of aluminium alloy with silicon carbide in NaCl environment decreased significantly with addition of the inhibitor.

  15. Effect of alloy elements on the anti-corrosion properties of low alloy steel

    Indian Academy of Sciences (India)

    Baorong Hou; Yantao Li; Yanxu Li; Jinglei Zhang

    2000-06-01

    Effect of alloy elements on corrosion of low alloy steel was studied under simulated offshore conditions. The results showed that the elements Cu, P, Mo, W, V had evident effect on corrosion resistance in the atmosphere zone; Cu, P, V, Mo in the splash zone and Cr, Al, Mo in the submerged zone.

  16. Standard classification of resistance to stress-corrosion cracking of heat-treatable Aluminum alloys

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This classification covers alphabetical ratings of the relative resistance to SCC of various mill product forms of the wrought 2XXX, 6XXX, and 7XXX series heat-treated aluminum alloys and the procedure for determining the ratings. 1.2 The ratings do not apply to metal in which the metallurgical structure has been altered by welding, forming, or other fabrication processes. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. In vitro corrosion behaviour and metallic ion release of different prosthodontic alloys.

    Science.gov (United States)

    Gil, F J; Sánchez, L A; Espías, A; Planell, J A

    1999-12-01

    The corrosion resistance for six metallic alloys often used in clinical dentistry, was evaluated by measuring their polarisation resistance in an artificial saliva environment. The critical current density (icr), the passive current density (ip), the corrosion potential (Ecorr) and the critical pitting potential (Ecp), were studied. Metallic ion release from the different alloys was analysed in a saliva environment at 37 degrees C. The nickel-chromium alloy exhibited important corrosion and a high quantity of ions was released. The titanium presented a low value of ion release and a good corrosion resistance due to the passive film on the metal surface. The high gold content alloy provided the best corrosion resistance.

  18. Corrosion behavior of Ti-39Nb alloy for dentistry.

    Science.gov (United States)

    Fojt, Jaroslav; Joska, Ludek; Malek, Jaroslav; Sefl, Vaclav

    2015-11-01

    To increase an orthopedic implant's lifetime, researchers are now concerned on the development of new titanium alloys with suitable mechanical properties (low elastic modulus-high fatigue strength), corrosion resistance and good workability. Corrosion resistance of the newly developed titanium alloys should be comparable with that of pure titanium. The effect of medical preparations containing fluoride ions represents a specific problem related to the use of titanium based materials in dentistry. The aim of this study was to determine the corrosion behavior of β titanium alloy Ti-39Nb in physiological saline solution and in physiological solution containing fluoride ions. Corrosion behavior was studied using standard electrochemical techniques and X-ray photoelectron spectroscopy. It was found that corrosion properties of the studied alloy were comparable with the properties of titanium grade 2. The passive layer was based on the oxides of titanium and niobium in several oxidation states. Alloying with niobium, which was the important part of the alloy passive layer, resulted in no significant changes of corrosion behavior. In the presence of fluoride ions, the corrosion resistance was higher than the resistance of titanium.

  19. Hot Corrosion of Cobalt-Base Alloys

    Science.gov (United States)

    1975-06-01

    scale is similar to that which has already been proposed for cobalt . The oxide ions would react with the Al203 to form aluminate ions in the Na2S04...resistance of cobalt -base and nickel-base alloys. The contract was accomplished under the technical direction of Dr. H. C. Graham of the Aerospace Research...Oxidized Specimens RESULTS AND DISCUSSION 1. INTRODUCfiON 2. SODIUM SULFATE INDUCED HOT CORROSION OF COBALT a. Introduction b. Experimental c

  20. Pre-oxidized and nitrided stainless steel alloy foil for proton exchange membrane fuel cell bipolar plates: Part 1. Corrosion, interfacial contact resistance, and surface structure

    Science.gov (United States)

    Brady, M. P.; Wang, H.; Turner, J. A.; Meyer, H. M.; More, K. L.; Tortorelli, P. F.; McCarthy, B. D.

    Thermal (gas) nitridation of stainless steel alloys can yield low interfacial contact resistance (ICR), electrically conductive and corrosion-resistant nitride containing surface layers (Cr 2N, CrN, TiN, V 2N, VN, etc.) of interest for fuel cells, batteries, and sensors. This paper presents results of scale-up studies to determine the feasibility of extending the nitridation approach to thin 0.1 mm stainless steel alloy foils for proton exchange membrane fuel cell (PEMFC) bipolar plates. Developmental Fe-20Cr-4V alloy and type 2205 stainless steel foils were treated by pre-oxidation and nitridation to form low-ICR, corrosion-resistant surfaces. As-treated Fe-20Cr-4V foil exhibited target (low) ICR values, whereas 2205 foil suffered from run-to-run variation in ICR values, ranging up to 2× the target value. Pre-oxidized and nitrided surface structure examination revealed surface-through-layer-thickness V-nitride particles for the treated Fe-20Cr-4V, but near continuous chromia for treated 2205 stainless steel, which was linked to the variation in ICR values. Promising corrosion resistance was observed under simulated aggressive PEMFC anode- and cathode-side bipolar plate conditions for both materials, although ICR values were observed to increase. The implications of these findings for stamped bipolar plate foils are discussed.

  1. DIMENSIONALLY STABLE, CORROSION RESISTANT NUCLEAR FUEL

    Science.gov (United States)

    Kittel, J.H.

    1963-10-31

    A method of making a uranium alloy of improved corrosion resistance and dimensional stability is described. The alloy contains from 0-9 weight per cent of an additive of zirconium and niobium in the proportions by weight of 5 to 1 1/ 2. The alloy is cold rolled, heated to two different temperatures, air-cooled, heated to a third temperature, and quenched in water. (AEC)

  2. Influence of surface modification of nitinol with silicon using plasma-immersion ion implantation on the alloy corrosion resistance in artificial physiological solutions

    Science.gov (United States)

    Kashin, O. A.; Borisov, D. P.; Lotkov, A. I.; Abramova, P. V.; Korshunov, A. V.

    2015-10-01

    Cyclic voltammetry and potentiostatic polarization have been applied to study electrochemical behavior and to determine corrosion resistance of nitinol, which surface was modified with silicon using plasma-immersion ion implantation, in 0.9% NaCl solution and in artificial blood plasma. It was found out that continuous, and also homogeneous in composition, thin Si-containing layers are resistant to corrosion damage at high positive potentials in artificial physiological solutions due to formation of stable passive films. Breakdown potential Eb of Si-modified NiTi depends on the character of silicon and Ni distribution at the alloy surface, Eb values amounted to 0.9-1.5 V (Ag/AgCl/KCl sat.) for the alloy samples with continuous Si-containing surface layers and with decreased Ni surface concentration.

  3. Transition of interface oxide layer from porous Mg(OH)2 to dense MgO induced by polyaniline and corrosion resistance of Mg alloy therefrom

    Science.gov (United States)

    Luo, Yizhong; Sun, Yang; Lv, Jinlong; Wang, Xianhong; Li, Ji; Wang, Fosong

    2015-02-01

    The feasibility of polyaniline emeraldine base (EB) for enhancing long-term corrosion resistance of magnesium alloy (AZ91D Mg alloy) was confirmed, since the complex impedance of Mg alloy protected by EB/epoxy resin (ER) composite coating with 10 wt% EB loading maintained around 2 GΩ cm2 even after 80 day exposure in 0.5 M NaCl solution, while that of pure ER coated analogue decreased to 0.17 MΩ cm2 only after 31 days. The improvement in corrosion resistance was attributed to the transition of interface layer from porous Mg(OH)2 dominated one underneath pure ER coating to dense MgO dominated one underneath EB/ER coating, induced by the redox interaction of EB with Mg alloy. When the EB loading in EB/ER coating increased from 0 to 10 wt%, the relative XPS peak area ratio of MgO to Mg(OH)2 increased from 0.78 to 1.18, indicating that EB behaved as effective corrosion inhibitor causing the transformation of oxide layer from porous Mg(OH)2 to dense MgO.

  4. Effect of Copper and Bronze Addition on Corrosion Resistance of Alloyed 316L Stainless Steel Cladded on Plain Carbon Steel by Powder Metallurgy

    Institute of Scientific and Technical Information of China (English)

    Wenjue CHEN; Yueying WU; Jianian SHEN

    2004-01-01

    A sandwich structure with cladding alloyed 316L stainless steel on plain carbon steel was prepared by means of powder metallurgy (PM) processing. Electrolytic Cu and prealloyed bronze (95Cu wt pct, 5Sn wt pct) were added in different contents up to 15% into the surface cladded 316L layers and the effect of alloying concentrations on the corrosion resistance of the 316L cladding layers was studied. The corrosion performances of the cladding samples were studied by immersion tests and potentio-dynamic anodic polarization tests in H2SO4 and FeCl3 solutions. Both 316L and alloyed 316L surface layers with 1.0 mm depth produced by PM cladding had an effect to improve corrosion resistance in H2SO4 and FeCl3 solutions. Small Cu and bronze addition (4%) had a positive effect in H2SO4 and FeCl3 solutions. 4% Cu alloyed 316L surface layer produced by PM cladding showed similar anodic polarization behaviour to the 316L cladding layer in H2SO4 and FeCl3 solutions.

  5. The corrosion resistance of composite arch wire laser-welded by NiTi shape memory alloy and stainless steel wires with Cu interlayer in artificial saliva with protein.

    Science.gov (United States)

    Zhang, Chao; Sun, Xinhua; Hou, Xu; Li, Hongmei; Sun, Daqian

    2013-01-01

    In this paper, the corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different concentrations of protein was studied. It was found that protein addition had a significant influence on the corrosion behavior of CoAW. Low concentration of protein caused the corrosion resistance of CoAW decrease in electrochemical corrosion and immersion corrosion tests. High concentration of protein could reduce this effect.

  6. The Corrosion Resistance of Composite Arch Wire Laser-Welded By NiTi Shape Memory Alloy and Stainless Steel Wires with Cu Interlayer in Artificial Saliva with Protein

    Science.gov (United States)

    Zhang, Chao; Sun, Xinhua; Hou, Xu; Li, Hongmei; Sun, Daqian

    2013-01-01

    In this paper, the corrosion resistance of laser-welded composite arch wire (CoAW) with Cu interlayer between NiTi shape memory alloy and stainless steel wire in artificial saliva with different concentrations of protein was studied. It was found that protein addition had a significant influence on the corrosion behavior of CoAW. Low concentration of protein caused the corrosion resistance of CoAW decrease in electrochemical corrosion and immersion corrosion tests. High concentration of protein could reduce this effect. PMID:23801895

  7. Influence of mill scale and rust layer on the corrosion resistance of low-alloy steel in simulated concrete pore solution

    Science.gov (United States)

    Shi, Jin-jie; Ming, Jing

    2017-01-01

    Electrochemical impedance spectroscopy, cyclic potentiodynamic polarization measurements, and scanning electron microscopy in conjunction with energy-dispersive X-ray spectroscopy were used to investigate the influence of mill scale and rust layer on the passivation capability and chloride-induced corrosion behaviors of conventional low-carbon (LC) steel and low-alloy (LA) steel in simulated concrete pore solution. The results show that mill scale exerts different influences on the corrosion resistance of both steels at various electrochemical stages. We propose that the high long-term corrosion resistance of LA steel is mainly achieved through the synergistic effect of a gradually formed compact, adherent and well-distributed Cr-enriched inner rust layer and the physical barrier protection effect of mill scale.

  8. Effects of Duplex Nitriding and TiN Coating Treatment on Wear Resistance, Corrosion Resistance and Biocompatibility of Ti6Al4V Alloy

    Science.gov (United States)

    Kao, W. H.; Su, Y. L.; Hsieh, Y. T.

    2017-08-01

    Ti6Al4V alloy substrates were nitrided at 900 °C. TiN coatings were then deposited on the nitrided substrates using a closed-field unbalanced magnetron sputtering system. The microstructure, hardness and adhesion properties of the TiN-N-Ti6Al4V substrates were evaluated and compared with those of an untreated Ti6Al4V sample, a nitrided Ti6Al4V sample and a TiN-coated Ti6Al4V sample, respectively. The tribological properties of the various samples were investigated by means of reciprocating sliding wear tests performed in 0.9 wt.% NaCl solution against 316L, Si3N4 and Ti6Al4V balls, respectively. In addition, the corrosion resistance was evaluated using potentiodynamic polarization tests. Finally, the biocompatibility of the samples was investigated by observing the attachment and growth of purified mouse leukemic monocyte/macrophage cells (Raw 264.7) on the sample surface after culturing periods of 24, 72 and 120 h, respectively. Overall, the results showed that the duplex nitriding/TiN coating treatment significantly improved the tribological, anti-corrosion and biocompatibility properties of the original Ti6Al4V alloy.

  9. Surface mechanical properties, corrosion resistance, and cytocompatibility of nitrogen plasma-implanted nickel-titanium alloys: a comparative study with commonly used medical grade materials.

    Science.gov (United States)

    Yeung, K W K; Poon, R W Y; Chu, P K; Chung, C Y; Liu, X Y; Lu, W W; Chan, D; Chan, S C W; Luk, K D K; Cheung, K M C

    2007-08-01

    Stainless steel and titanium alloys are the most common metallic orthopedic materials. Recently, nickel-titanium (NiTi) shape memory alloys have attracted much attention due to their shape memory effect and super-elasticity. However, this alloy consists of equal amounts of nickel and titanium, and nickel is a well known sensitizer to cause allergy or other deleterious effects in living tissues. Nickel ion leaching is correspondingly worse if the surface corrosion resistance deteriorates. We have therefore modified the NiTi surface by nitrogen plasma immersion ion implantation (PIII). The surface chemistry and corrosion resistance of the implanted samples were studied and compared with those of the untreated NiTi alloys, stainless steel, and Ti-6Al-4V alloy serving as controls. Immersion tests were carried out to investigate the extent of nickel leaching under simulated human body conditions and cytocompatibility tests were conducted using enhanced green fluorescent protein mice osteoblasts. The X-ray photoelectron spectroscopy results reveal that a thin titanium nitride (TiN) layer with higher hardness is formed on the surface after nitrogen PIII. The corrosion resistance of the implanted sample is also superior to that of the untreated NiTi and stainless steel and comparable to that of titanium alloy. The release of nickel ions is significantly reduced compared with the untreated NiTi. The sample with surface TiN exhibits the highest amount of cell proliferation whereas stainless steel fares the worst. Compared with coatings, the plasma-implanted structure does not delaminate as easily and nitrogen PIII is a viable way to improve the properties of NiTi orthopedic implants.

  10. Effects Of T6 Heat Treatment With Double Solution Treatment On Microstructure, Hardness And Corrosion Resistance Of Cast Al-Si-Cu Alloy

    Directory of Open Access Journals (Sweden)

    Wiengmoon A.

    2015-06-01

    Full Text Available Effects of T6 heat treatment with double solution treatment on microstructure, hardness and corrosion resistance of a cast A319 (Al-4.93wt%Si-3.47wt%Cu alloy were investigated. The T6 heat treatment comprised of the first solution treatment at 500±5°C for 8 h, the second solution treatment in the temperature range of 510 to 530±5°C for 2 h followed by water quenching (80°C, and artificial aging at 170°C for 24 h followed by water quenching (80°C. Microstructure of the alloy was studied by optical microscopy and electron microscopy, Rockwell hardness was measured, and corrosion resistance in 0.1 M NaCl aqueous solution was determined by a potentiodynamic technique. The results revealed that the T6 heat treatment with double solution treatment led to an improvement in corrosion resistance and comparable macrohardness as compared to those obtained from the case of single solution treatment. The second solution treatment at 520°C is the optimum leading to relatively low corrosion current density without substantial drawbacks on breakdown potential or the width of passive range.

  11. Corrosion resistance and biocompatibility of magnesium alloy modified by alkali heating treatment followed by the immobilization of poly (ethylene glycol), fibronectin and heparin.

    Science.gov (United States)

    Pan, Changjiang; Hu, Youdong; Hou, Yu; Liu, Tao; Lin, Yuebin; Ye, Wei; Hou, Yanhua; Gong, Tao

    2017-01-01

    In recent years, magnesium alloys are attracting more and more attention as a kind of biodegradable metallic biomaterials, however, their uncontrollable biodegradation speed in vivo and the limited surface biocompatibility hinder their clinical applications. In the present study, with the aim of improving the corrosion resistance and biocompatibility, the magnesium alloy (AZ31B) surface was modified by alkali heating treatment followed by the self-assembly of 3-aminopropyltrimethoxysilane (APTMS). Subsequently, poly (ethylene glycol) (PEG) and fibronectin or fibronectin/heparin complex were sequentially immobilized on the modified surface. The results of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) and X-ray photoelectron spectroscopy (XPS) confirmed that the above molecules were successfully immobilized on the magnesium alloy surface. An excellent hydrophilic surface was obtained after the alkali heating treatment while the hydrophilicity decreased to some degree after the self-assembly of APTMS, the surface hydrophilicity was gradually improved again after the immobilization of PEG, fibronectin or fibronectin/heparin complex. The corrosion resistance of the control magnesium alloy was significantly improved by the alkali heating treatment. The self-assembly of APTMS and the following immobilization of PEG further enhanced the corrosion resistance of the substrates, however, the grafting of fibronectin or fibronectin/heparin complex slightly lowered the corrosion resistance. As compared to the pristine magnesium alloy, the samples modified by the immobilization of PEG and fibronectin/heparin complex presented better blood compatibility according to the results of hemolysis assay and platelet adhesion as well as the activated partial thromboplastin time (APTT). In addition, the modified substrates had better cytocompatibility to endothelial cells due to the improved anticorrosion and the introduction of fibronectin. The substrates

  12. Corrosion resistant iron aluminides exhibiting improved mechanical properties and corrosion resistance

    Science.gov (United States)

    Liu, Chain T.; McKamey, Claudette G.; Tortorelli, Peter F.; David, Stan A.

    1994-01-01

    The specification discloses a corrosion-resistant intermetallic alloy comprising, in atomic percent, an FeAl iron aluminide containing from about 30 to about 40% aluminum alloyed with from about 0.01 to 0.4% zirconium and from 0.01 to about 0.8% boron. The alloy exhibits considerably improved room temperature ductility for enhanced usefulness in structural applications. The high temperature strength and fabricability is improved by alloying with molybdenum, carbon, chromium and vanadium.

  13. An improved stress corrosion test medium for aluminum alloys

    Science.gov (United States)

    Humphries, T. S.; Coston, J. E.

    1981-01-01

    A laboratory test method that is only mildly corrosive to aluminum and discriminating for use in classifying the stress corrosion cracking resistance of aluminum alloys is presented along with the method used in evaluating the media selected for testing. The proposed medium is easier to prepare and less expensive than substitute ocean water.

  14. Effects of increase extent of voltage on wear and corrosion resistance of micro-arc oxidation coatings on AZ91D alloy

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The effects of increase extent of voltage on the wear resistance and corrosion resistance of micro-arc oxidation(MAO)coatings on AZ91D magnesium alloy were investigated in silicate electrolyte.The results show that with increasing extent of voltage,both of the thickness and bonding force of MAO coatings first increase,and then decrease.These parameters are all up to their maximum values when the increase extent of voltage is 20 V.The roughness of the coatings always increases.The coating has the best corrosion resistance when the increase extent of voltage is not below 25 V,and the coating has the best wear resistance when the increase extent of voltage is 10 V.The wear mechanisms for the micro-arc oxidation are abrasive wear and micromachining wear.These are related to their microstructures.

  15. Isothermal corrosion Fe3Si alloy in liquid zinc

    Institute of Scientific and Technical Information of China (English)

    Wen jun Wang; Junping Lin; Yanli Wang; Guoliang Chen

    2007-01-01

    The isothermal corrosion testing,microscopic examination and the performance of Fe3Si alloy as materials of construction for bath hardware in continuous hot-dipping lines were studied.The corrosion of Fe3Si alloy in molten zinc was controlled by attacking the grain boundaries preferentially.Aluminum reacted with iron of Fe3Si alloy firstly while the samples were immersed in molten zinc,although aluminum contents in the molten zinc were very low.The phase of reaction product was thought to be Fe2Al5.The corrosion rate of the Fe3Si alloy in molten zinc was determined to be approximately 2.9×10-3 mm/h,therefore the liquid zinc corrosion resistance of Fe3Si alloy was very weak.

  16. Corrosion Behaviour of New Zr Alloys

    DEFF Research Database (Denmark)

    Tolksdorf, E.

    1974-01-01

    Corrosion studies have indicated that the most promising replacements for Zicaloy-2 are ZrCrFe, ZrVFe and probably ZrNbTa, provided they are in their optimized condition. These alloys are conventionally manufactured alloys. An internally oxidized ZrMgO alloy is even superior, from the corrosion...

  17. Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venith Jojee Pulikkottil

    2016-01-01

    Full Text Available Objective: (1 To evaluate the corrosion resistance of four different orthodontic archwires and to determine the effect of 0.5% NaF (simulating high fluoride-containing toothpaste of about 2250 ppm on corrosion resistance of these archwires. (2 To assess whether surface roughness (Ra is the primary factor influencing the corrosion resistance of these archwires. Materials and Methods: Four different archwires (stainless steel [SS], nickel-titanium [NiTi], titanium molybdenum alloy [TMA], and ion-implanted TMA were considered for this study. Surface characteristics were analyzed using scanning electron microscopy, atomic force microscopy (AFM, and energy dispersive spectroscopy. Linear polarization test, a fast electrochemical technique, was used to evaluate the corrosion resistance, in terms of polarization resistance of four different archwires in artificial saliva with NaF concentrations of 0% and 0.5%. Statistical analysis was performed by one-way analysis of variance. Results: The potentiostatic study reveals that the corrosion resistance of low-friction TMA (L-TMA > TMA > NiTi > SS. AFM analysis showed the surface Ra of TMA > NiTi > L-TMA > SS. This indicates that the chemical composition of the wire is the primary influential factor to have high corrosion resistance and surface Ra is only secondary. The corrosion resistance of all wires had reduced significantly in 0.5% acidic fluoride-containing artificial saliva due to formation of fluoride complex compound. Conclusion: The presence of 0.5% NaF in artificial saliva was detrimental to the corrosion resistance of the orthodontic archwires. Therefore, complete removal of residual high-fluorinated toothpastes from the crevice between archwire and bracket during tooth brushing is mandatory.

  18. Corrosion resistance of stainless steel, nickel-titanium, titanium molybdenum alloy, and ion-implanted titanium molybdenum alloy archwires in acidic fluoride-containing artificial saliva: An in vitro study

    Science.gov (United States)

    Pulikkottil, Venith Jojee; Chidambaram, S.; Bejoy, P. U.; Femin, P. K.; Paul, Parson; Rishad, Mohamed

    2016-01-01

    Objective: (1) To evaluate the corrosion resistance of four different orthodontic archwires and to determine the effect of 0.5% NaF (simulating high fluoride-containing toothpaste of about 2250 ppm) on corrosion resistance of these archwires. (2) To assess whether surface roughness (Ra) is the primary factor influencing the corrosion resistance of these archwires. Materials and Methods: Four different archwires (stainless steel [SS], nickel-titanium [NiTi], titanium molybdenum alloy [TMA], and ion-implanted TMA) were considered for this study. Surface characteristics were analyzed using scanning electron microscopy, atomic force microscopy (AFM), and energy dispersive spectroscopy. Linear polarization test, a fast electrochemical technique, was used to evaluate the corrosion resistance, in terms of polarization resistance of four different archwires in artificial saliva with NaF concentrations of 0% and 0.5%. Statistical analysis was performed by one-way analysis of variance. Results: The potentiostatic study reveals that the corrosion resistance of low-friction TMA (L-TMA) > TMA > NiTi > SS. AFM analysis showed the surface Ra of TMA > NiTi > L-TMA > SS. This indicates that the chemical composition of the wire is the primary influential factor to have high corrosion resistance and surface Ra is only secondary. The corrosion resistance of all wires had reduced significantly in 0.5% acidic fluoride-containing artificial saliva due to formation of fluoride complex compound. Conclusion: The presence of 0.5% NaF in artificial saliva was detrimental to the corrosion resistance of the orthodontic archwires. Therefore, complete removal of residual high-fluorinated toothpastes from the crevice between archwire and bracket during tooth brushing is mandatory. PMID:27829756

  19. Preparation, corrosion resistance and hemocompatibility of the superhydrophobic TiO2 coatings on biomedical Ti-6Al-4V alloys

    Science.gov (United States)

    Jiang, J. Y.; Xu, J. L.; Liu, Z. H.; Deng, L.; Sun, B.; Liu, S. D.; Wang, L.; Liu, H. Y.

    2015-08-01

    In this paper the micro-arc oxidation (MAO) technique and subsequent superhydrophobic treatment were applied to fabricate the superhydrophobic TiO2 coatings on biomedical Ti-6Al-4V alloys. The surface morphology, surface roughness, water contact angle, corrosion resistance and hemocompatibility of the MAO and superhydrophobic samples were investigated. The results showed that the single anatase TiO2 coating was formed on the surface Ti-6Al-4V alloy with rough and porous micrometer-scale structure. The low surface energy film was grafted on the surface of the TiO2 coating by self-assembling reaction during the hydrophobic treatment process, which resulted in the formation of superhydrophobic surfaces with the water contact angle of 153.39°. It was found that the corrosion resistance of the superhydrophobic samples increased by one order of magnitude compared to those of the uncoated Ti-6Al-4V alloys. The hemolysis ratio and platelets adhesion characteristics of the Ti-6Al-4V alloys were also improved greatly through the MAO treatment and subsequent superhydrophobic treatment. Especially, no platelet could be observed on the surface of the superhydrophobic samples. Therefore, the superhydrophobic TiO2 coatings of Ti-6Al-4V alloys with higher hemocompatibility would show great promise in their potential blood-contacting applications.

  20. Corrosion resistance of ZrTi alloys with hydroxyapatite-zirconia-silver layer in simulated physiological solution containing proteins for biomaterial applications

    Science.gov (United States)

    Mareci, D.; Trincă, L. C.; Căilean, D.; Souto, R. M.

    2016-12-01

    The degradation characteristics of hydroxyapatite-zirconia-silver films (HA-ZrO2-Ag) coatings on three ZrTi alloys were investigated in Ringer's solution containing 10% human albumin protein at 37 °C. Samples were immersed for 7 days while monitored by electrochemical impedance spectroscopy (EIS) and linear potentiodynamic polarization (LPP). The electrochemical analysis in combination with surface analytical characterization by scanning electron microscopy (SEM/EDX) reveals the stability and corrosion resistance of the HA-ZrO2-Ag coated ZrTi alloys. The characteristic feature that describes the electrochemical behaviour of the coated alloys is the coexistence of large areas of the coating presenting pores in which the ZrTi alloy substrate is exposed to the simulated physiological environment. The EIS interpretation of results was thus performed using a two-layer model of the surface film. The blocking effect in the presence the human albumin protein produces an enhancement of the corrosion resistance. The results disclose that the Zr45Ti alloy is a promising material for biomedical devices, since electrochemical stability is directly associated to biocompatibility.

  1. Effect of the Heat Treatment on the Mechanical Property and Corrosion Resistance of CU - 7Al - 2.5Si Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Syung-Yul; Won, Jong-Pil; Park, Dong-Hyun; Moon, Kyung-Man; Lee, Myeong-Hoon; Jeong, Jin-A [Korea Maritime and Ocean Univ., Busan (Korea, Republic of); Baek, Tae-Sil [Pohang College, Pohang (Korea, Republic of)

    2014-02-15

    Recently, the fuel oil of diesel engines of marine ships has been increasingly changed to heavy oil of low quality as the oil price is getting higher and higher. Therefore, the spiral gear attached at the motor of the oil purifier which plays an important role to purify the heavy oil is also easy to expose at severe environmental condition due to the purification of the heavy oil in higher temperature. Thus, the material of the spiral gear requires a better mechanical strength, wear and corrosion resistance. In this study, the heat treatment(tempering) with various holding time at temperature of 500 .deg. C was carried out to the alloy of Cu-7Al-2.5Si as centrifugal casting, and the properties of both hardness and corrosion resistance with and without heat treatment were investigated with observation of the microstructure and with electrochemical methods, such as measurement of corrosion potential, cathodic and anodic polarization curves, cyclic voltammogram, and a.c. impedance. in natural seawater solution. The α, β and γ{sub 2} phases were observed in the material in spite of no heat treatment due to quenching effect of a spin mold. However, their phases, that is, β and γ{sub 2} phases decreased gradually with increasing the holding time at a constant temperature of 500 .deg. C. The hardness more or less decreased with heat treatment, however its corrosion resistance was improved with the heat treatment. Furthermore, the longer holding time, the better corrosion resistance. In addition, when the holding time was 48hrs, its corrosion current density showed the lowest value. The pattern of corroded surface was nearly similar to that of the pitting corrosion, and this morphology was greatly observed in the case of no heat treatment. It is considered that γ{sub 2} phase at the grain boundary was corroded preferentially as an anode. However, the pattern of general corrosion exhibited increasingly due to decreasing the γ{sub 2} phase with heat treatment

  2. Enhanced corrosion resistance and hemocompatibility of biomedical NiTi alloy by atmospheric-pressure plasma polymerized fluorine-rich coating

    Energy Technology Data Exchange (ETDEWEB)

    Li, Penghui; Li, Limin [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China); Wang, Wenhao [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China); Division of Spine Surgery, Department of Orthopaedics and Traumatology, Pokfulam, Hong Kong (China); Jin, Weihong [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China); Liu, Xiangmei [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China); Ministry of Education Key Laboratory for the Green Preparation and Application of Functional Materials, Hubei University, Wuhan, Hubei 430062 (China); Yeung, Kelvin W.K. [Division of Spine Surgery, Department of Orthopaedics and Traumatology, Pokfulam, Hong Kong (China); Chu, Paul K., E-mail: paul.chu@cityu.edu.hk [Department of Physics and Materials Science, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong (China)

    2014-04-01

    Highlights: • Fluoropolymer is deposited on NiTi alloy via atmospheric-pressure plasma polymerization. • The corrosion resistance of NiTi alloy in SBF and DMEM is evidently improved. • The adsorption ratio of albumin to fibrinogen is increased on the coated surface. • The reduced platelet adhesion number indicates better in vitro hemocompatibility. - Abstract: To improve the corrosion resistance and hemocompatibility of biomedical NiTi alloy, hydrophobic polymer coatings are deposited by plasma polymerization in the presence of a fluorine-containing precursor using an atmospheric-pressure plasma jet. This process takes place at a low temperature in air and can be used to deposit fluoropolymer films using organic compounds that cannot be achieved by conventional polymerization techniques. The composition and chemical states of the polymer coatings are characterized by fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS). The corrosion behavior of the coated and bare NiTi samples is assessed and compared by polarization tests and electrochemical impedance spectroscopy (EIS) in physiological solutions including simulated body fluids (SBF) and Dulbecco's Modified Eagle's medium (DMEM). The corrosion resistance of the coated NiTi alloy is evidently improved. Protein adsorption and platelet adhesion tests reveal that the adsorption ratio of albumin to fibrinogen is increased and the number of adherent platelets on the coating is greatly reduced. The plasma polymerized coating renders NiTi better in vitro hemocompatibility and is promising as a protective and hemocompatible coating on cardiovascular implants.

  3. Corrosion Studies of 2195 Al-Li Alloy and 2219 Al Alloy with Differing Surface Treatments

    Science.gov (United States)

    Danford, M. D.; Mendrek, M. J.

    1998-01-01

    Corrosion studies of 2195 Al-Li and 2219 Al alloys have been conducted using the scanning reference electrode technique (SRET) and the polarization resistance (PR) technique. The SRET was used to study corrosion mechanisms, while corrosion rate measurements were studied with the PR technique. Plates of Al203 blasted, soda blasted and conversion coated 2219 Al were coated with Deft primer and the corrosion rates studied with the EIS technique. Results from all of these studies are presented.

  4. Corrosion resistance and magnetostrictive properties of (Tb0.3Dy0.7)Fe2 alloy modified by nitrogen ion implantation

    Institute of Scientific and Technical Information of China (English)

    杨红川; 张世荣; 于敦波; 李扩社; 胡权霞; 杨远飞; 张坤; 李红卫

    2015-01-01

    The corrosion resistance and magnetostriction of (Tb0.3Dy0.7)Fe2 alloy were investigated for different nitrogen doses of 5×1015, 5×1016, 5×1017, 1×1018 ions/cm2 and average ion energy of 140 kV. The phase and elements concentration in the implanted layer were examined by X-ray diffraction and auger electron spectroscopy, respectively.The aqueous corrosion studies were carried out in 3.5% NaCl solutions. It was found that corrosion resistance had improved substantially with respect to the untreated substrates.The corrosion resistance was maximum at a dose of 5×1017 ions/cm2, and saturation in corrosion improvement was noticed at a higher dose, 10×1017 ions/cm2.In contrast, the results of magnetostriction tests before and after ion implantation showed that the influence of ni-trogen ion implantation on the magnetostrictive properties turned out to be small. Finally, a model was applied to interpret the influ-ence of nitrogen implantation on the magnetostriction in the light of the information provided by the experimental results in this study.

  5. Mechanical Property and Corrosion Resistance Evaluations of Ti-6Al-7Nb Alloy Brazed with Bulk Metallic Glasses

    Energy Technology Data Exchange (ETDEWEB)

    Miura, E. [Nagasaki University, Nagasaki, Japan; Kato, H. [Tohoku University, Japan; Ogata, Toshiaki [Nagasaki University, Nagasaki, Japan; Nishiyama, Nobuyuki [Tohoku University, Japan; Specht, Eliot D [ORNL; Shiraishi, Takanobu [ORNL; Inoue, A. [Tohoku University, Japan; Hisatsune, K. [Nagasaki University, Nagasaki, Japan

    2007-01-01

    Exploitation of metallic glass as new brazing filler for Ti-based biomedical alloy was attempted. Ti-6Al-7Nb was used as a brazed material, and candidates of bulk metallic glass brazing filler were Cu60Hf25Ti15, Mg65Cu25Gd10, Zr55Cu30Al10Ni5 and Pd40Cu30P20Ni10. Convergence infrared-ray brazing was conducted for brazing Ti-6Al-7Nb/metallic glass in Ar atmosphere. After brazing, hardness measurement, X-ray tomography, cross-sectional observation, artificial saliva immersion test and tensile test were performed to evaluate brazability, mechanical property and corrosion resistance of the obtained brazing joints. The results of brazing using these metallic glass fillers show that all the metallic glasses were brazable to Ti-6Al-7Nb except for Mg65Cu25Gd10. Mg65Cu25Gd10, Cu60Hf25Ti15 and their joints collapsed rapidly during immersion test. Zr55Cu30Al10Ni5 joint was the best in terms of degradation resistance; however, tensile strength was inferior to the conventional one. Pd40Cu30Ni10P20 filler and Zr55Cu30Al10Ni5 filler and their joints did not show any collapse or tarnish during the immersion test. Pd40Cu30Ni10P20 joint showed the excellent properties in terms of both corrosion resistance and tensile strength, which were superior to a joint brazed using Ti-15Cu-25Ni conventional filler. X-ray tomograph indicates that fracture tends to occur in the vicinity of the brazing interface after tensile test. The brazed metallic glass fillers were fully crystallized, excluding Pd40Cu30Ni10P20 filler. Pd40Cu30Ni10P20 brazed filler contained mapleleaf like primary dendrite, peritectoid and a few microns interfacial reaction layer in glassy matrix. The results indicated that Pd40Cu30Ni10P20 is promising brazing filler for dental or biomaterial devices.

  6. Corrosion performance of structural alloys.

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K.

    1999-07-15

    Component reliability and long-term trouble-free performance of structural materials are essential in power-generating and gasification processes that utilize coal as a feedstock. During combustion and conversion of coal, the environments encompass a wide range of oxygen partial pressures, from excess-air conditions in conventional boilers to air-deficient conditions in 10W-NO{sub x} and gasification systems. Apart from the environmental aspects of the effluent from coal combustion and conversion, one concern from the systems standpoint is the aggressiveness of the gaseous/deposit environment toward structural components such as waterwall tubes, steam superheaters, syngas coolers, and hot-gas filters. The corrosion tests in the program described in this paper address the individual and combined effects of oxygen, sulfur, and chlorine on the corrosion response of several ASME-coded and noncoded structural alloys that were exposed to air-deficient and excess-air environments typical of coal-combustion and gasification processes. Data in this paper address the effects of preoxidation on the subsequent corrosion performance of structural materials such as 9Cr-1Mo ferritic steel, Type 347 austenitic stainless steel, Alloys 800, 825, 625, 214, Hastelloy X, and iron aluminide when exposed at 650 C to various mixed-gas environments with and without HCI. Results are presented for scaling kinetics, microstructural characteristics of corrosion products, detailed evaluations of near-surface regions of the exposed specimens, gains in our mechanistic understanding of the roles of S and Cl in the corrosion process, and the effect of preoxidation on subsequent corrosion.

  7. Fabrication of a novel Mg-RE (Nd,Ce) intermetallic compound coating by molten salt diffusion and its effect on corrosion resistance of magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    韩宝军; 古东懂; 何琼; 张小联; 彭光怀; 杨初斌

    2016-01-01

    A novel Mg-rare earth (Nd,Ce) coating containing intermetallic compound was fabricated on the surface of the AZ91D magnesium alloy by bathing the sample in a NaCl-KCl-LiCl-NdCl3-CeCl3 molten salt. The cross-sectional morphology, microstruc-ture and phase composition of the coating were investigated by scanning electron microscopy (SEM), transmission electron micros-copy (TEM) and energy dispersive spectroscopy (EDS). The corrosion resistance was characterized by the potentiodynamic polariza-tion curves. The SEM observation indicated that a continuous and compact diffusion coating was obtained on the surface of SMATed AZ91D magnesium alloy and the XRD and TEM investigations revealed that the new phases were Al2Ce and Al2Nd intermetallic. The potentiodynamic polarization curves showed that the Mg-RE coating improved the corrosion resistance of the AZ91D magne-sium alloy, and the corrosion current density of the coated sample was about 1510 mA/cm2 lower than the uncoated sample.

  8. Corrosion-resistant metal surfaces

    Science.gov (United States)

    Sugama, Toshifumi [Wading River, NY

    2009-03-24

    The present invention relates to metal surfaces having thereon an ultrathin (e.g., less than ten nanometer thickness) corrosion-resistant film, thereby rendering the metal surfaces corrosion-resistant. The corrosion-resistant film includes an at least partially crosslinked amido-functionalized silanol component in combination with rare-earth metal oxide nanoparticles. The invention also relates to methods for producing such corrosion-resistant films.

  9. Enhanced corrosion resistance of magnesium alloy by a silane-based solution treatment after an in-situ formation of the Mg(OH)2 layer

    Science.gov (United States)

    Gong, Fubao; Shen, Jun; Gao, Runhua; Xie, Xiong; Luo, Xiong

    2016-03-01

    A novel organic-inorganic Mg(OH)2/silane surface layer has been developed for corrosion protection of AZ31 magnesium alloy. The results of electrochemical impedance spectroscopy (EIS), the immersion tests, Fourier-transform infrared spectroscopy (FTIR) and sellotape tests showed that the Mg(OH)2/silane-based composite surface layer possessed excellent corrosion resistance and very good adhesion due to the formation of Si-O-Mg bond between Mg(OH)2 layer and silane layer. Electrochemical impedance spectroscopy tests results indicated that for the long-term corrosion protection of AZ31 the increase of the curing temperature improved the impedance of the composited layer when the curing temperature was lower than 130 °C. However, the impedance of the composited layer deceased when the curing temperature was more than 130 °C due to the carbonization of the silane layer.

  10. Surface Treatment to Improve Corrosion Resistance in Lead-Alloy Coolants

    Energy Technology Data Exchange (ETDEWEB)

    Todd R. Allen; Kumar Sridharan; McLean T. Machut; Lizhen Tan

    2007-08-29

    One of the six proposed advanced reactor designs of the Generation IV Initiative, the Leadcooled Fast Reactor (LFR) possesses many characteristics that make it a desirable candidate for future nuclear energy production and responsible actinide management. These characteristics include favorable heat transfer, fluid dynamics, and neutronic performance compared to other candidate coolants. However, the use of a heavy liquid metal coolant presents a challenge for reactor designers in regards to reliable structural and fuel cladding materials in both a highly corrosive high temperature liquid metal and an intense radiation fieldi. Flow corrosion studies at the University of Wisconsin have examined the corrosion performance of candidate materials for application in the LFR concept as well as the viability of various surface treatments to improve the materials’ compatibility. To date this research has included several focus areas, which include the formulation of an understanding of corrosion mechanisms and the examination of the effects of chemical and mechanical surface modifications on the materials’ performance in liquid lead-bismuth by experimental testing in Los Alamos National Laboratory’s DELTA Loop, as well as comparison of experimental findings to numerical and physical models for long term corrosion prediction. This report will first review the literature and introduce the experiments and data that will be used to benchmark theoretical calculations. The experimental results will be followed by a brief review of the underlying theory and methodology for the physical and theoretical models. Finally, the results of theoretical calculations as well as experimentally obtained benchmarks and comparisons to the literature are presented.

  11. Passive behaviour of alloy corrosion-resistant steel Cr10Mo1 in simulating concrete pore solutions with different pH

    Science.gov (United States)

    Ai, Zhiyong; Jiang, Jinyang; Sun, Wei; Song, Dan; Ma, Han; Zhang, Jianchun; Wang, Danqian

    2016-12-01

    The passive behaviour of new alloy corrosion-resistant steel Cr10Mo1 and plain carbon steel (as a comparison) in simulating concrete pore solutions of different pH (ranging from 13.5 to 9.0) under open circuit potential conditions, was evaluated by various electrochemical techniques: potentiodynamic polarization, capacitance measurements and electrochemical impedance spectroscopy. The chemical composition and structure of passive films were investigated by X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS). The electrochemical responses of passive films show that Cr10Mo1 steel has an increasing passivity with pH decreasing while carbon steel dose conversely, revealing carbonation does no negative effect on passivation of the corrosion-resistant steel. SIMS reveals that the passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer mainly consisting of Fe oxides and hydroxides, and an inner layer enriched in Cr species, while only a Fe-concentrated layer for carbon steel. According to the XPS analysis results, as the pH decreases, more stable and protective Cr oxides are enriched in the film on Cr10Mo1 steel while Fe oxides gradually decompose. Higher content of Cr oxides in the film layer provides Cr10Mo1 corrosion-resistant steel more excellent passivity at lower pH.

  12. Development of weldable, corrosion-resistant iron-aluminide (FeAl) alloys

    Energy Technology Data Exchange (ETDEWEB)

    Maziasz, P.J.; Goodwin, G.M.; Wang, X.L.; Alexander, D.J. [Oak Ridge National Lab., TN (United States)

    1997-04-01

    A boron-microalloyed FeAl alloy (Fe-36Al-0.2Mo-0.05Zr-0.13C, at.%, with 100-400 appm B) with improved weldability and mechanical properties was developed in FY 1994. A new scale-up and industry technology development phase for this work began in FY 1995, pursuing two parallel paths. One path was developing monolithic FeAl component and application technology, and the other was developing coating/cladding technology for alloy steels, stainless steels and other Fe-Cr-Ni alloys. In FY 1995, it was found that cast FeAl alloys had good strength at 700-750{degrees}C, and some (2.5%) ductility in air at room-temperature. Hot-extruded FeAl with refined grain size was found to have ductility and to also have good impact-toughness at room-temperature. Further, it was discovered that powder-metallurgy (P/M) FeAl, consolidated by direct hot-extrusion at 950-1000{degrees}C to have an ultra fine-grained microstructure, had the highest ductility, strength and impact-toughness ever seen in such intermetallic alloys.

  13. A study on corrosion resistant graphene films on low alloy steel

    Directory of Open Access Journals (Sweden)

    A. S. Sai Pavan

    2016-04-01

    Full Text Available Abstract Graphene nanosheets were produced after synthesizing graphene oxide via Hummer’s method and a modified Hummer’s method. The obtained graphene after reduction was dispersed in 1-propanol to get a coating solution. Mild steel coupons were coated with the graphene solution via dip coating method. Corrosion studies were carried out at different environments like water (pH 6.0, HCl (0.1 N, NaCl (3.5 wt% and NaOH (1 M. Tafel analysis showed a reduction in the corrosion rate up to 99 % after three layer deposition with the graphene developed using the modified Hummer’s method. X-ray diffraction and Raman Spectroscopy confirmed the presence of graphene.

  14. A study on corrosion resistant graphene films on low alloy steel

    Science.gov (United States)

    Sai Pavan, A. S.; Ramanan, Sutapa Roy

    2016-11-01

    Graphene nanosheets were produced after synthesizing graphene oxide via Hummer's method and a modified Hummer's method. The obtained graphene after reduction was dispersed in 1-propanol to get a coating solution. Mild steel coupons were coated with the graphene solution via dip coating method. Corrosion studies were carried out at different environments like water (pH 6.0), HCl (0.1 N), NaCl (3.5 wt%) and NaOH (1 M). Tafel analysis showed a reduction in the corrosion rate up to 99 % after three layer deposition with the graphene developed using the modified Hummer's method. X-ray diffraction and Raman Spectroscopy confirmed the presence of graphene.

  15. Electrophoretic Deposition, Microstructure, and Corrosion Resistance of Porous Sol-Gel Glass/Polyetheretherketone Coatings on the Ti-13Nb-13Zr Alloy

    Science.gov (United States)

    Moskalewicz, Tomasz; Zych, Anita; Łukaszczyk, Alicja; Cholewa-Kowalska, Katarzyna; Kruk, Adam; Dubiel, Beata; Radziszewska, Agnieszka; Berent, Katarzyna; Gajewska, Marta

    2017-02-01

    In this study, microporous composite sol-gel glass/polyetheretherketone (SGG/PEEK) coatings were produced on the Ti-13Nb-13Zr titanium alloy by electrophoretic deposition. Coatings with different levels of high open porosity were developed by introducing SGG particles of varying diameters into the PEEK matrix. The microstructure of the coatings was characterized by electron microscopy and X-ray diffractometry. The coatings with 40-50 µm thickness were composed of semicrystalline SGG particles consisting of hydroxyapatite, CaSiO3, some Ca2SiO4, and an amorphous phase containing Ca, Si, P, and O, homogeneously embedded in a semicrystalline PEEK matrix. The size of SGG particles present in the coatings strongly influenced the formation of microcracks and their adhesion to the underlying substrate. Microscratch tests showed that the coating containing SGG particles with a diameter smaller than 45 µm and open porosity of 45 pct exhibited good adhesion to the titanium alloy substrate, much better than the coating containing particles with a diameter smaller than 85 µm and total open porosity equal to 48 pct. The corrosion resistance was investigated in Ringer's solution at a temperature of 310 K (37 °C) for a pH equal to 7.4 and in deaerated solutions with the use of open-circuit potential, potentiodynamic polarization, and electrochemical impedance spectroscopy. The SGG/PEEK-coated alloy indicated better electrochemical corrosion resistance compared with the uncoated alloy.

  16. Microstructure and corrosion resistance of Fe-Al intermetallic coating on 45 steel synthesized by double glow plasma surface alloying technology

    Institute of Scientific and Technical Information of China (English)

    ZHU Xiao-lin; YAO Zheng-jun; GU Xue-dong; CONG Wei; ZHANG Ping-ze

    2009-01-01

    A binary Fe-Al alloyed layer was synthesized on 45 steel by means of double glow plasma surface alloying technique. The corrosion-resisting layer prepared is composed of a sedimentary layer and a diffusion layer, with a total thickness of about 180 μm. The aluminum content of the alloyed layer shows gradual change from surface to the inside of substrate. The ideal profile is beneficial to the metallurgical bonding of the surface alloying layer with substrate materials. The microstructure of both layers consists of the Fe-Al intermetallic compound, which is FeAl with B2 structure in the sedimentary layer and Fe3Al with incompletely ordered DO3 structure in the diffusion layer. The protective film exhibits high micro-hardness. In comparison with the substrate of 45 steel, the corrosion resistance of the aluminized sample is much higher in 2.0% Na2S and 0.05 mol/L Na2SO4 + 0.5 mol/L NaCl mixed solutions.

  17. Electrophoretic Deposition, Microstructure, and Corrosion Resistance of Porous Sol-Gel Glass/Polyetheretherketone Coatings on the Ti-13Nb-13Zr Alloy

    Science.gov (United States)

    Moskalewicz, Tomasz; Zych, Anita; Łukaszczyk, Alicja; Cholewa-Kowalska, Katarzyna; Kruk, Adam; Dubiel, Beata; Radziszewska, Agnieszka; Berent, Katarzyna; Gajewska, Marta

    2017-05-01

    In this study, microporous composite sol-gel glass/polyetheretherketone (SGG/PEEK) coatings were produced on the Ti-13Nb-13Zr titanium alloy by electrophoretic deposition. Coatings with different levels of high open porosity were developed by introducing SGG particles of varying diameters into the PEEK matrix. The microstructure of the coatings was characterized by electron microscopy and X-ray diffractometry. The coatings with 40-50 µm thickness were composed of semicrystalline SGG particles consisting of hydroxyapatite, CaSiO3, some Ca2SiO4, and an amorphous phase containing Ca, Si, P, and O, homogeneously embedded in a semicrystalline PEEK matrix. The size of SGG particles present in the coatings strongly influenced the formation of microcracks and their adhesion to the underlying substrate. Microscratch tests showed that the coating containing SGG particles with a diameter smaller than 45 µm and open porosity of 45 pct exhibited good adhesion to the titanium alloy substrate, much better than the coating containing particles with a diameter smaller than 85 µm and total open porosity equal to 48 pct. The corrosion resistance was investigated in Ringer's solution at a temperature of 310 K (37 °C) for a pH equal to 7.4 and in deaerated solutions with the use of open-circuit potential, potentiodynamic polarization, and electrochemical impedance spectroscopy. The SGG/PEEK-coated alloy indicated better electrochemical corrosion resistance compared with the uncoated alloy.

  18. Improvement of the Corrosion Resistance of High Alloyed Austenitic Cr-Ni-Mo Stainless Steels by Solution Nitriding

    Institute of Scientific and Technical Information of China (English)

    Christine Eckstein; Heinz- Joachim Spies; Jochen Albrecht

    2004-01-01

    Characteristic features of austenitic steel grades combine a good corrosion resistance with a low hardness, wear resistance and scratch resistance. An interesting possibility for improving the wear behaviour of these steels without loss of their corrosion resistance lies in enriching the near surface region with nitrogen. The process of a solution nitriding allows the rise of the solution of nitrogen in the solid phase. On this state nitrogen increases the corrosion resistance and the tribilogical load-bearing capacity. The aim of the study was, to investigate the improvement of the pitting corrosion behaviour by solution nitriding. A special topic was to observe the effect of nitrogen by different molybdenum content. So austenitic stainless steels (18% Cr, 12% Ni, Mo gradation between 0.06 to 3.6%) had been solution nitrided. The samples could be prepared with various surface content of nitrogen from 0.04 to 0.45% with a step-by-step grinding. The susceptibility against pitting corrosion of these samples had been tested by determination of the stable pitting potential in 0.5M and 1M NaCl at 25℃. For the investigated steel composition and the used corrosion system there is no influence of molybdenum on the effectiveness of nitrogen. The influence of nitrogen to all of the determined parameters can be corrosion tests. Additionally surface investigations with an acid elektolyte (0,1M HCl + 0,4M NaCI) were performed. In this case the passivation effective nitrogen content increases markedly with rising molybdenum concentration of the steel.Obviously an interaction of Mo and N is connected with a strongly acid electrolyte.

  19. Intermetallic particles-induced pitting corrosion in 6061-T651 aluminium alloy

    CSIR Research Space (South Africa)

    Mutombo, K

    2011-07-01

    Full Text Available -Induced Pitting Corrosion in 6061-T651 Aluminium Alloy Kalenda Mutombo Council for Scientific and Industrial Research (CSIR), South Africa kmutombo@csir.co.za Keywords: pitting corrosion, 6061-T651 aluminium alloy, intermetallic particles, 3.5% Na... extrudability, reasonable weldability and good corrosion resistance. This alloy finds widespread application in ship building and in the fabrication of tank containers for transporting various liquids. 6061-T651 aluminium alloy is, however, prone to pitting...

  20. Corrosion behavior of nickel-containing alloys in artificial sweat.

    Science.gov (United States)

    Randin, J P

    1988-07-01

    The corrosion resistance of various nickel-containing alloys was measured in artificial sweat (perspiration) using the Tafel extrapolation method. It was found that Ni, CuNi 25 (coin alloy), NiAl (colored intermetallic compounds), WC + Ni (hard metal), white gold (jewelry alloy), FN42 and Nilo Alby K (controlled expansion alloys), and NiP (electroless nickel coating) are in an active state and dissolve readily in oxygenated artificial sweat. By contrast, austenitic stainless steels, TiC + Mo2C + Ni (hard metal), NiTi (shape-memory alloy), Hastelloy X (superalloy), Phydur (precipitation hardening alloy), PdNi and SnNi (nickel-containing coatings) are in a passive state but may pit under certain conditions. Cobalt, Cr, Ti, and some of their alloys were also investigated for the purpose of comparison. Cobalt and its alloys have poor corrosion resistance except for Stellite 20. Chromium and high-chromium ferritic stainless steels have a high pitting potential but the latter are susceptible to crevice corrosion. Ti has a pitting potential greater than 3 V. Comparison between the in vitro measurements of the corrosion rate of nickel-based alloys and the clinical observation of the occurrence of contact dermatitis is discussed.

  1. Passivation Characteristics of Alloy Corrosion-Resistant Steel Cr10Mo1 in Simulating Concrete Pore Solutions: Combination Effects of pH and Chloride

    Directory of Open Access Journals (Sweden)

    Zhiyong Ai

    2016-09-01

    Full Text Available The electrochemical behaviour for passivation of new alloy corrosion-resistant steel Cr10Mo1 immersed in alkaline solutions with different pH values (13.3, 12.0, 10.5, and 9.0 and chloride contents (0.2 M and 1.0 M, was investigated by various electrochemical techniques: linear polarization resistance, electrochemical impedance spectroscopy and capacitance measurements. The chemical composition and structure of passive films were determined by XPS. The morphological features and surface composition of the immersed steel were evaluated by SEM together with EDS chemical analysis. The results evidence that pH plays an important role in the passivation of the corrosion-resistant steel and the effect is highly dependent upon the chloride contents. In solutions with low chloride (0.2 M, the corrosion-resistant steel has notably enhanced passivity with pH falling from 13.3 to 9.0, but does conversely when in presence of high chloride (1.0 M. The passive film on the corrosion-resistant steel presents a bilayer structure: an outer layer enriched in Fe oxides and hydroxides, and an inner layer, rich in Cr species. The film composition varies with pH values and chloride contents. As the pH drops, more Cr oxides are enriched in the film while Fe oxides gradually decompose. Increasing chloride promotes Cr oxides and Fe oxides to transform into their hydroxides with little protection, and this is more significant at lower pH (10.5 and 9.0. These changes annotate passivation characteristics of the corrosion-resistant steel in the solutions of different electrolyte.

  2. Corrosion evaluation of gold-based dental alloys.

    Science.gov (United States)

    Corso, P P; German, R M; Simmons, H D

    1985-05-01

    Three commercial gold-based dental alloys and three constant-nobility ternary alloys (Au-Ag-Cu) were evaluated for corrosion using a quantitative test battery. Integration of the current density, in a de-aerated solution of 1% NaCl along the approximate potential range found in the mouth (-300 mV to +300 mV vs. SCE), yields a quantitative rank ordering of the test alloys. The results are combined with prior findings on other commercial alloys to demonstrate the interaction of nobility and microstructure. Nobility determines the overall corrosion resistance for gold-based alloys. However, because of mutual insolubility, alloying with copper induces silver segregation, resulting in a higher corrosion rate at a given nobility. Thus, microstructure has an influence on corrosion, but heat treatments are largely ineffective in altering the basic corrosion characteristics. The test techniques, in combination with tarnish evaluations, provide a quantitative battery for alloy evaluation. The results indicate the combinations of nobility, microstructure, and environment most likely to avoid corrosion difficulties.

  3. Protective Effect of the Sputtered TiAlCrAg Coating on the High-Temperature Oxidation and Hot Corrosion Resistance of Ti-Al-Nb Alloy

    Institute of Scientific and Technical Information of China (English)

    Yanjun XI; Fuhui WANG; Lianlong HE

    2004-01-01

    The effect of a sputtered Ti-48Al-8Cr-2Ag (at. pct) coating on the oxidation resistance of the cast Ti-46.5Al-5Nb (at. pct) alloy was investigated in air at 1000~1100℃. Hot corrosion in molten 75 wt pct Na2SO4+25 wt pct K2SO4 was investigated at 900℃. The scale on the cast TiAlNb tends to spall in air, while the scale on coating is very adherent. The sputtered Ti-48Al-8Cr-2Ag coating remarkably improved high temperature oxidation resistance of the cast Ti-46.5Al-5Nb alloy because of the formation of an adherent Al2O3 scale. Due to the inward diffusion of Cr,Kirkendall voids were found at the coating/substrate interface. TiAlCrAg coating provided excellent hot corrosion resistance for TiAlNb alloy in molten 75 wt pct Na2SO4+25 wt pct K2SO4 at 900℃ due to the formation of a continuous Al2O3 scale.

  4. Microstructure and corrosion resistance of Ni-based alloy laser coatings with nanosize CeO2 addition

    Directory of Open Access Journals (Sweden)

    Shi Hong Zhang et al

    2008-01-01

    Full Text Available Micron-size Ni-base alloy (NBA powders were mixed with both 1.5 wt.% (hereinafter % micron-size CeO2 (m-CeO2 and also 1.5% and 3.0% nano-size CeO2 (n- CeO2 powders. These mixtures were coated on low-carbon steel (Q235 by 2.0 kW CO2 laser cladding. The effects on the microstructures, phases and electrochemical corrosion of the coatings upon the addition of m- and n- CeO2 powders to NBA (m- and n- CeO2 /NBA have been investigated. The results showed that a smooth coating was prepared under suitable processing parameters (P= 2.0 kW, V= 180 mm min- 1 by adding 1.5% n- CeO2. In addition to the primary phases of γ-Ni, Cr23 C6 and Ni3 B in the Ni-base alloy coating, CeNi3 was formed in Ni-base alloy coatings with both n- CeO2 and m-CeO2 particles, and CeNi5 appeared in the coating upon decreasing the size of CeO2 particles. Well-developed dendrites were observed in the Ni-base alloy coating; directional dendrites grew at the interface in the coating upon the addition of m-CeO2, whereas fine and multioriented dendrites grew upon decreasing the size of CeO2 particles to the nanoscale. Actinomorphic dendrites and compact equiaxed dendrites grew from the interface to near the surface upon increasing the content of n- CeO2 from 1.5 to 3.0%. In strongly acidic HNO3 solution, the severe corrosion of dendrites occurred and there were many corrosion pits in the Ni-base alloy coating; intercrystalline corrosion also has a dominant role upon the addition of m-CeO2, whereas uniform corrosion occurs in the coating as the size of CeO2 particles is decreased to nanoscale.

  5. Microstructure and corrosion resistance of Ni-based alloy laser coatings with nanosize CeO2 addition.

    Science.gov (United States)

    Hong Zhang, Shi; Xi Li, Ming; Hong Yoon, Jae; Yul Cho, Tong; Zhu He, Yi; Gyu Lee, Chan

    2008-07-01

    Micron-size Ni-base alloy (NBA) powders were mixed with both 1.5 wt.% (hereinafter %) micron-size CeO2 (m-CeO2) and also 1.5% and 3.0% nano-size CeO2 (n- CeO2) powders. These mixtures were coated on low-carbon steel (Q235) by 2.0 kW CO2 laser cladding. The effects on the microstructures, phases and electrochemical corrosion of the coatings upon the addition of m- and n- CeO2 powders to NBA (m- and n- CeO2 /NBA) have been investigated. The results showed that a smooth coating was prepared under suitable processing parameters (P= 2.0 kW, V= 180 mm min(- 1)) by adding 1.5% n- CeO2. In addition to the primary phases of γ-Ni, Cr23C6 and Ni3B in the Ni-base alloy coating, CeNi3 was formed in Ni-base alloy coatings with both n- CeO2 and m-CeO2 particles, and CeNi5 appeared in the coating upon decreasing the size of CeO2 particles. Well-developed dendrites were observed in the Ni-base alloy coating; directional dendrites grew at the interface in the coating upon the addition of m-CeO2, whereas fine and multioriented dendrites grew upon decreasing the size of CeO2 particles to the nanoscale. Actinomorphic dendrites and compact equiaxed dendrites grew from the interface to near the surface upon increasing the content of n- CeO2 from 1.5 to 3.0%. In strongly acidic HNO3 solution, the severe corrosion of dendrites occurred and there were many corrosion pits in the Ni-base alloy coating; intercrystalline corrosion also has a dominant role upon the addition of m-CeO2, whereas uniform corrosion occurs in the coating as the size of CeO2 particles is decreased to nanoscale.

  6. Synthesis and characterization of binder-free Cr{sub 3}C{sub 2} coatings on nickel-based alloys for molten fluoride salt corrosion resistance

    Energy Technology Data Exchange (ETDEWEB)

    Brupbacher, Michael C.; Zhang, Dajie [Department of Materials Science and Engineering, The Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States); Buchta, William M. [The Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Graybeal, Mark L. [U.S. Army Research Laboratory, Aberdeen Proving Ground, MD 21005 (United States); Rhim, Yo-Rhin [The Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Nagle, Dennis C. [Department of Materials Science and Engineering, The Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States); Spicer, James B., E-mail: spicer@jhu.edu [Department of Materials Science and Engineering, The Johns Hopkins University, 3400 North Charles Street, Baltimore, MD 21218 (United States)

    2015-06-15

    Under various conditions, chromium carbides appear to be relatively stable in the presence of molten fluoride salts and this suggests that their use in corrosion resistant coatings for fluoride salt environments could be beneficial. One method for producing these coatings is the carburization of sprayed Cr coatings using methane-containing gaseous precursors. This process has been investigated for the synthesis of binder-free chromium carbide coatings on nickel-based alloy substrates for molten fluoride salt corrosion resistance. The effects of the carburization process on coating microstructure have been characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM) in conjunction with energy dispersive spectroscopy (EDS). Both plasma-sprayed and cold-sprayed Cr coatings have been successfully converted to Cr{sub 3}C{sub 2}, with the mechanism of conversion being strongly influenced by the initial porosity in the as-deposited coatings.

  7. Deposition of nanostructured fluorine-doped hydroxyapatite-polycaprolactone duplex coating to enhance the mechanical properties and corrosion resistance of Mg alloy for biomedical applications.

    Science.gov (United States)

    Bakhsheshi-Rad, H R; Hamzah, E; Kasiri-Asgarani, M; Jabbarzare, S; Iqbal, N; Abdul Kadir, M R

    2016-03-01

    The present study addressed the synthesis of a bi-layered nanostructured fluorine-doped hydroxyapatite (nFHA)/polycaprolactone (PCL) coating on Mg-2Zn-3Ce alloy via a combination of electrodeposition (ED) and dip-coating methods. The nFHA/PCL composite coating is composed of a thick (70-80 μm) and porous layer of PCL that uniformly covered the thin nFHA film (8-10 μm) with nanoneedle-like microstructure and crystallite size of around 70-90 nm. Electrochemical measurements showed that the nFHA/PCL composite coating presented a high corrosion resistance (R(p)=2.9×10(3) kΩ cm(2)) and provided sufficient protection for a Mg substrate against galvanic corrosion. The mechanical integrity of the nFHA/PCL composite coatings immersed in SBF for 10 days showed higher compressive strength (34% higher) compared with the uncoated samples, indicating that composite coatings can delay the loss of compressive strength of the Mg alloy. The nFHA/PCL coating indicted better bonding strength (6.9 MPa) compared to PCL coating (2.2 MPa). Immersion tests showed that nFHA/PCL composite-coated alloy experienced much milder corrosion attack and more nucleation sites for apatite compared with the PCL coated and uncoated samples. The bi-layered nFHA/PCL coating can be a good alternative method for the control of corrosion degradation of biodegradable Mg alloy for implant applications.

  8. Microbial corrosion of aluminum alloy.

    Science.gov (United States)

    Yang, S S; Chen, C Y; Wei, C B; Lin, Y T

    1996-11-01

    Several microbes were isolated from the contaminated fuel-oil in Taiwan and the microbial corrosion of aluminum alloy A356-T6 was tested by MIL-STD-810E test method. Penicillium sp. AM-F5 and Cladosporium resinac ATCC 22712 had significant adsorption and pitting on the surface of aluminum alloy, Pseudomonas acruginosa AM-B5 had weak adsorption and some precipitation in the bottom, and Candida sp. AM-Y1 had the less adsorption and few cavities formation on the surface. pH of the aqueous phase decreased 0.3 to 0.7 unit for 4 months of incubation. The corrosion of aluminum alloy was very significant in the cultures of Penicillium sp. AM-F2, Penicillium sp. AM-F5 and C. resinac ATCC 22712. The major metabolites in the aqueous phase with the inoculation of C. resinac were citric acid and oxalic acid, while succinic acid and fumaric acid were the minors.

  9. Otimização do banho eletrolítico da liga Fe-W-B resistente à corrosão Optimization of the electrolytic bath for electrodeposition of corrosion resistant Fe-W-B alloys

    Directory of Open Access Journals (Sweden)

    Renato Alexandre Costa de Santana

    2007-04-01

    Full Text Available A study on optimization of bath parameters for electrodeposition of Fe-W-B alloys from plating baths containing ammonia and citrate is reported. A 2³ full factorial design was successfully employed for experimental design analysis of the results. The corrosion resistance and amorphous character were evaluated. The bath conditions obtained for depositing the alloy with good corrosion resistance were: 0.01 M iron sulfate, 0.10 M sodium tungstate and 0.60 M ammonium citrate. The alloy was deposited at 12% current efficiency. The alloy obtained had Ecorr -0.841 V and Rp 1.463 x 10(4 Ohm cm². The deposit obtained under these conditions had an amorphous character and no microcracks were observed on its surface. Besides this, the bath conditions obtained for depositing the alloy with the highest deposition efficiency were: 0.09 M iron sulfate, 0.30 M sodium tungstate and 0.50 M ammonium citrate. The alloy was deposited at 50% current efficiency, with an average composition of 34 wt% W, 66 wt% Fe and traces of boron. The alloy obtained had Ecorr -0.800 V and Rp 1.895 x 10³ Ohm cm². Electrochemical corrosion tests verified that the Fe-W-B alloy deposited under both conditions had better corrosion resistance than Fe-Mo-B.

  10. Corrosion resistant PEM fuel cell

    Science.gov (United States)

    Fronk, Matthew Howard; Borup, Rodney Lynn; Hulett, Jay S.; Brady, Brian K.; Cunningham, Kevin M.

    2002-01-01

    A PEM fuel cell having electrical contact elements comprising a corrosion-susceptible substrate metal coated with an electrically conductive, corrosion-resistant polymer containing a plurality of electrically conductive, corrosion-resistant filler particles. The substrate may have an oxidizable metal first layer (e.g., stainless steel) underlying the polymer coating.

  11. Corrosion behavior of Mg and Mg-Zn alloys in simulated body fluid

    Institute of Scientific and Technical Information of China (English)

    GAO Jia-cheng; WU Sha; QIAO Li-ying; WANG Yong

    2008-01-01

    The corrosion behavior of Mg and Mg-Zn in simulated body fluid was studied.The mass loss of pure Mg,Mg-Zn-Zr and Mg-Zn-Zr-Y in simulated body fluid was measured using photovoltaic scale meter.Corrosion rate was determined through electrochemical tests.Finally,the corrosion mechanism was tbermodynamically studied.The results show that the corrosion rate decreases with the lapse of time for both pure Mg and Mg alloys.The purer the alloy,the borer the corrosion resistance exhibits.The corrosion behavior of Mg alloy is improved by the addition of trace Y.

  12. Bio-Corrosion of Magnesium Alloys for Orthopaedic Applications

    Directory of Open Access Journals (Sweden)

    Emily K. Brooks

    2017-09-01

    Full Text Available Three Mg alloys, Mg–1.34% Ca–3% Zn (MCZ, Mg–1.34% Ca–3% Zn–0.2% Sr (MCZS, and Mg–2% Sr (MS, were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM of alloy microstructure was performed to help interpret the results of the electrochemical testing. Results indicate that corrosion resistance of the alloys is as follows: MCZ > MCZS > MS.

  13. Comparison of corrosion behaviors of AZ31, AZ91,AM60 and ZK60 magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    CHENG Ying-liang; QIN Ting-wei; WANG Hui-min; ZHANG Zhao

    2009-01-01

    The corrosion behaviours of four kinds of rolled magnesium alloys of AZ31, AZ91, AM60 and ZK60 were studied in 1 mol/L sodium chloride solution. The results of EIS and potentiodynamic polarization show that the corrosion resistance of the four materials is ranked as ZK60>AM60>AZ31>AZ91. The corrosion processes of the four magnesium alloys were also analyzed by SEM and energy dispersive spectroscopy(EDS). The results show that the corrosion patterns of the four alloys are localized corrosion and the galvanic couples formed by the second phase particles and the matrix are the main source of the localized corrosion of magnesium alloys. The corrosion resistance of the different magnesium alloys has direct relationship with the concentration of alloying elements and microstructure of magnesium alloys. The ratio of the β phase in AZ91 is higher than that in AZ31 and the β phase can form micro-galvanic cell with the alloy matrix, as a result, the corrosion resistance of AZ31 will be higher than AZ91. The manganese element in AM60 magnesium alloy can form the second phase particle of AlMnFe, which can reduce the Fe content in magnesium alloy matrix, purifying the microstructure of alloy, as a result, the corrosion resistance of AM60 is improved. However, due to the more noble galvanic couples of AlMnFe and matrix, the microscopic corrosion morphology of AM60 is more localized. The zirconium element in ZK60 magnesium alloy can refine grain, form stable compounds with Fe and Si, and purify the composition of alloy, which results in the good corrosion resistance of ZK60 magnesium alloy.

  14. Corrosion wear fracture of new {beta} biomedical titanium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Niinomi, M.; Fukunaga, K.-I. [Toyohashi Univ. of Technol. (Japan). Dept. of Production Syst. Eng.; Kuroda, D.; Morinaga, M.; Kato, Y.; Yashiro, T.; Suzuki, A.

    1999-05-15

    Metallic materials such as stainless steel, Co-Cr alloy, pure titanium and titanium alloys have been used for surgical implant materials. The {alpha} + {beta} type titanium alloy such as Ti-6Al-4V ELI has been most widely used as an implant material for artificial hip joint and dental implant because of its high strength and excellent corrosion resistance. Toxicity of alloying elements in conventional biomedical titanium alloys like Al and V, and the high modulus of elasticity of these alloy as compared to that of bone have been, however, pointed out [1,2]. New {beta} type titanium alloys composed of non-toxic elements like Nb, Ta, Zr, Mo and Sn with lower moduli of elasticity, greater strength and greater corrosion resistance were, therefore, designed in this study. The friction wear properties of titanium alloys are, however, low as compared to those of other conventional metallic implant materials such as stainless steels and Co-Cr alloy. Tensile tests and friction wear tests in Ringer`s solution were conducted in order to investigate the mechanical properties of designed alloys. The friction wear characteristics of designed alloys and typical conventional biomedical titanium alloys were evaluated using a pin-on-disk type friction wear testing system and measuring the weight loss and width of groove of the specimen. (orig.) 8 refs.

  15. Corrosion and wear resistant metallic layers produced by electrochemical methods

    DEFF Research Database (Denmark)

    Christoffersen, Lasse; Maahn, Ernst Emanuel

    1999-01-01

    Corrosion and wear-corrosion properties of novel nickel alloy coatings with promising production characteristics have been compared with conventional bulk materials and hard platings. Corrosion properties in neutral and acidic environments have been investigated with electrochemical methods....... Determination of polarisation resistance during 100 hours followed by stepwise anodic polarisation seems to be a promising technique to obtain steady state data on slowly corroding coatings with transient kinetics. A slurry test enables determination of simultaneous corrosion and abrasive wear. Comparison...

  16. Galvanic corrosion behavior of titanium implants coupled to dental alloys.

    Science.gov (United States)

    Cortada, M; Giner, L; Costa, S; Gil, F J; Rodríguez, D; Planell, J A

    2000-05-01

    The corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium implant. Various electrochemical parameters E(CORR), i(CORR) Evans diagrams, polarization resistance and Tafel slopes) were analyzed. The microstructure of the different dental materials was observed before and after corrosion processes by optical and electron microscopy. Besides, the metallic ions released in the saliva environment were quantified during the corrosion process by means of inductively coupled plasma-mass spectrometry technique (ICP-MS). The cast and machined titanium had the most passive current density at a given potential and chromium-nickel alloy had the most active critical current density values. The high gold content alloys have excellent resistance corrosion, although this decreases when the gold content is lower in the alloy. The palladium alloy had a low critical current density due to the presence of gallium in this composition but a selective dissolution of copper-rich phases was observed through energy dispersive X-ray analysis.

  17. Formation of Surface Corrosion-Resistant Nanocrystalline Structures on Steel.

    Science.gov (United States)

    Nykyforchyn, Hryhoriy; Kyryliv, Volodymyr; Maksymiv, Olha; Slobodyan, Zvenomyra; Tsyrulnyk, Oleksandr

    2016-12-01

    Engineering materials with nanocrystalline structure could be exploited under simultaneous action of mechanical loading and corrosion environments; therefore, their corrosion resistance is important. Surface nanocrystalline structure was generated on middle carbon steels by severe plastic deformation using the method of mechanical pulse friction treatment. This treatment additionally includes high temperature phase transformation and alloying. Using a complex of the corrosive, electrochemical and physical investigations, it was established that nanocrystalline structures can be characterized by lower or increased corrosion resistance in comparison with the reference material. It is caused by the action of two confronting factors: arising energy level and anticorrosive alloying of the surface layer.

  18. Corrosion Behavior of AlSi10Mg Alloy Produced by Additive Manufacturing (AM vs. Its Counterpart Gravity Cast Alloy

    Directory of Open Access Journals (Sweden)

    Avi Leon

    2016-06-01

    Full Text Available The attractiveness of additive manufacturing (AM relates to the ability of this technology to rapidly produce very complex components at affordable costs. However, the properties and corrosion behavior, in particular, of products produced by AM technology should at least match the properties obtained by conventional technologies. The present study aims at evaluating the corrosion behavior and corrosion fatigue endurance of AlSi10Mg alloy produced by selective laser melting (SLM in comparison with its conventional counterpart, gravity cast alloy. The results obtained indicate that the corrosion resistance of the printed and cast alloys was relatively similar, with a minor advantage to the printed alloy. The corrosion fatigue endurance of the printed alloy was relatively improved compared to the cast alloy. This was mainly attributed to the significant differences between the microstructure and defect characteristics of those two alloys.

  19. Structure and corrosion resistance of ZrO{sub 2} ceramic coatings on AZ91D Mg alloys by plasma electrolytic oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Yao Zhongping, E-mail: yaozhongping@hit.edu.cn [School of Chemical Engineering and Technology, Harbin Institute of Technology Harbin 150001 (China); Postdoctoral Station of Chemistry Engineering and Technology, Harbin Institute of Technology, Harbin 150001 (China); Xu Yongjun; Liu Yunfu; Wang Dali; Jiang Zhaohua; Wang Fuping [School of Chemical Engineering and Technology, Harbin Institute of Technology Harbin 150001 (China)

    2011-08-18

    Highlights: > The ZrO{sub 2} ceramic coatings on AZ91D Mg alloys was prepared in tripolyphosphate and fluorozirconate solution. > The double-layer structure with the loose and porous outer layer and the compact inner layer was analyzed by SEM and EIS technique > The polarization resistance obtained from the equivalent circuit of the EIS was consistent with the results of the polarizing curves tests. - Abstract: The aim of this work is to study the structure and the corrosion resistance of the plasma electrolytic oxidation ZrO{sub 2} ceramic coatings on Mg alloys. The ceramic coatings were prepared on AZ91D Mg alloy in Na{sub 5}P{sub 3}O{sub 10} and K{sub 2}ZrF{sub 6} solution by pulsed single-polar plasma electrolytic oxidation (PEO). The phase composition, morphology and element distribution in the coating were investigated by X-ray diffractometry, scanning electron microscopy and energy distribution spectroscopy, respectively. The results show that the coating thickness and surface roughness were increased with the increase of the reaction time. The ceramic coatings were of double-layer structure with the loose and porous outer layer and the compact inner layer. And the coating was composed of P, Zr, Mg and K, of which P and Zr were the main elements in the coating. P in the coating existed in the form of amorphous state, while Zr crystallized in the form of t-ZrO{sub 2} and a little c-ZrO{sub 2} in the coating. Electrochemical impedance spectra (EIS) and the polarizing curve tests of the coatings were measured through CHI604 electrochemical analyzer in 3.5% NaCl solution to evaluate the corrosion resistance. The polarization resistance obtained from the equivalent circuit of the EIS was consistent with the results of the polarizing curves tests.

  20. Pitting corrosion resistance and bond strength of stainless steel overlay by friction surfacing on high strength low alloy steel

    Directory of Open Access Journals (Sweden)

    Amit Kumar Singh

    2015-09-01

    Full Text Available Surface modification is essential for improving the service properties of components. Cladding is one of the most widely employed methods of surface modification. Friction surfacing is a candidate process for depositing the corrosion resistant coatings. Being a solid state process, it offers several advantages over conventional fusion based surfacing process. The aim of this work is to identify the relationship between the input variables and the process response and develop the predictive models that can be used in the design of new friction surfacing applications. In the current work, austenitic stainless steel AISI 304 was friction surfaced on high strength low alloy steel substrate. Friction surfacing parameters, such as mechtrode rotational speed, feed rate of substrate and axial force on mechtrode, play a major role in determining the pitting corrosion resistance and bond strength of friction surfaced coatings. Friction surfaced coating and base metal were tested for pitting corrosion by potentio-dynamic polarization technique. Coating microstructure was characterized using optical microscopy, scanning electron microscopy and X-ray diffraction. Coatings in the as deposited condition exhibited strain-induced martensite in austenitic matrix. Pitting resistance of surfaced coatings was found to be much lower than that of mechtrode material and superior to that of substrate. A central composite design with three factors (mechtrode rotational speed, substrate traverse speed, axial load on mechtrode and five levels was chosen to minimize the number of experimental conditions. Response surface methodology was used to develop the model. In the present work, an attempt has been made to develop a mathematical model to predict the pitting corrosion resistance and bond strength by incorporating the friction surfacing process parameters.

  1. Corrosion behavior of leaded-bronze alloys in sea water

    Energy Technology Data Exchange (ETDEWEB)

    Zohdy, K.M., E-mail: khalzohdy@yahoo.com [Higher Technological Institute, 10" t" h of Ramadan City (Egypt); Sadawy, M.M. [Mining and Petroleum Engineering Department, Al-Azhar University, Nasr City, Cairo 11371 (Egypt); Ghanem, M. [Industrial Education, Suez University (Egypt)

    2014-10-15

    The corrosion behavior of leaded-bronze alloys (Cu–5Sn–5Zn–5Pb, Cu–8Sn–8Zn–8Pb and Cu–10Sn–10Zn–10Pb) in sea water was investigated using weight loss method, open-circuit potential measurements (OCP), polarization techniques and electrochemical impedance spectroscopy (EIS). The nature and morphology of the corrosion products were investigated by scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the corrosion resistance decreases with decreasing copper content. The XRD indicated that the composition of patina depends on the concentration of Cu, Sn, Zn and Pb in each alloy. - Highlights: • The corrosion potential of leaded bronze shifts to more noble potential. • The corrosion resistance increases with increasing amount of copper content in leaded bronze alloys. • The patina formed on Cu–5Sn–5Zn–5Pb is more uniform and protective than other alloys. • The composition of patina formed on leaded bronze depends on the concentration of Cu, Sn, Zn and Pb in the alloy.

  2. The Corrosion and Corrosion Fatigue Behavior of Nickel Based Alloy Weld Overlay and Coextruded Claddings

    Science.gov (United States)

    Stockdale, Andrew

    The use of low NOx boilers in coal fired power plants has resulted in sulfidizing corrosive conditions within the boilers and a reduction in the service lifetime of the waterwall tubes. As a solution to this problem, Ni-based weld overlays are used to provide the necessary corrosion resistance however; they are susceptible to corrosion fatigue. There are several metallurgical factors which give rise to corrosion fatigue that are associated with the localized melting and solidification of the weld overlay process. Coextruded coatings offer the potential for improved corrosion fatigue resistance since coextrusion is a solid state coating process. The corrosion and corrosion fatigue behavior of alloy 622 weld overlays and coextruded claddings was investigated using a Gleeble thermo-mechanical simulator retrofitted with a retort. The experiments were conducted at a constant temperature of 600°C using a simulated combustion gas of N2-10%CO-5%CO2-0.12%H 2S. An alternating stress profile was used with a minimum tensile stress of 0 MPa and a maximum tensile stress of 300 MPa (ten minute fatigue cycles). The results have demonstrated that the Gleeble can be used to successfully simulate the known corrosion fatigue cracking mechanism of Ni-based weld overlays in service. Multilayer corrosion scales developed on each of the claddings that consisted of inner and outer corrosion layers. The scales formed by the outward diffusion of cations and the inward diffusion of sulfur and oxygen anions. The corrosion fatigue behavior was influenced by the surface finish and the crack interactions. The initiation of a large number of corrosion fatigue cracks was not necessarily detrimental to the corrosion fatigue resistance. Finally, the as-received coextruded cladding exhibited the best corrosion fatigue resistance.

  3. Influence of heat treatment on bond strength and corrosion resistance of sol-gel derived bioglass-ceramic coatings on magnesium alloy.

    Science.gov (United States)

    Shen, Sibo; Cai, Shu; Xu, Guohua; Zhao, Huan; Niu, Shuxin; Zhang, Ruiyue

    2015-05-01

    In this study, bioglass-ceramic coatings were prepared on magnesium alloy substrates through sol-gel dip-coating route followed by heat treatment at the temperature range of 350-500°C. Structure evolution, bond strength and corrosion resistance of samples were studied. It was shown that increasing heat treatment temperature resulted in denser coating structure as well as increased interfacial residual stress. A failure mode transition from cohesive to adhesive combined with a maximum on the measured bond strength together suggested that heat treatment enhanced the cohesion strength of coating on the one hand, while deteriorated the adhesion strength of coating/substrate on the other, thus leading to the highest bond strength of 27.0MPa for the sample heat-treated at 450°C. This sample also exhibited the best corrosion resistance. Electrochemical tests revealed that relative dense coating matrix and good interfacial adhesion can effectively retard the penetration of simulated body fluid through the coating, thus providing excellent protection for the underlying magnesium alloy.

  4. Corrosion behaviour of polished and sandblasted titanium alloys in PBS solution.

    Science.gov (United States)

    Burnat, Barbara; Walkowiak-Przybyło, Magdalena; Błaszczyk, Tadeusz; Klimek, Leszek

    2013-01-01

    In this work, we performed comparative studies of the effect of surface preparation of Ti6Al4V and Ti6Al7Nb biomedical alloys and the influence of endothelial cells on their corrosion behaviour in PBS (Phosphate Buffered Saline). Two different methods of surface modification were applied - polishing and sandblasting. The polished Ti6Al7Nb alloy was found to have the best resistance against general corrosion in PBS. It was characterized by the lowest corrosion rate, the widest passive range and the lowest reactivity. Both alloys prepared by sandblasting exhibited worse corrosion properties in comparison to the polished ones. This can be associated with a greater development of their surface and the presence of Al2O3 grains which caused an increase of corrosion potential but might also influence the weakening of the passive layer. Results of potentiodynamic anodic polarization indicated that more resistant to pitting corrosion was Ti6Al7Nb alloy regardless of the method of surface preparation. In those cases, anodic polarization caused only an increase of passive layer, while in the case of sandblasted Ti6Al4V alloy it caused a pitting corrosion. The results obtained allowed us to conclude that the niobium-titanium alloys had higher corrosion resistance than titanium alloys with vanadium. Moreover, it was stated that endothelial cells improved the corrosion resistance of all the titanium alloys examined.

  5. Systematic corrosion investigation of various Cu-Sn alloys electrodeposited on mild steel in acidic solution: Dependence of alloy composition

    Energy Technology Data Exchange (ETDEWEB)

    Suerme, Yavuz, E-mail: ysurme@nigde.edu.t [Department of Chemistry, Faculty of Science and Art, Nigde University, 51200 Nigde (Turkey); Guerten, A. Ali [Department of Chemistry, Faculty of Science and Art, Osmaniye Korkut Ata University, 80000 Osmaniye (Turkey); Bayol, Emel; Ersoy, Ersay [Department of Chemistry, Faculty of Science and Art, Nigde University, 51200 Nigde (Turkey)

    2009-10-19

    Copper-tin alloy films were galvanostatically electrodeposited on the mild steel (MS) by combining the different amount of Cu and Sn electrolytes at a constant temperature (55 deg. C) and pH (3.5). Alloy films were characterized by using the energy dispersive X-ray analysis (EDX), scanning electron microscopy (SEM), X-ray diffraction (XRD) and micrographing techniques. Corrosion behaviours were evaluated with electrochemical impedance spectrometry (EIS) and electrochemical polarization measurements. Time gradient of electrolysis process was adjusted to obtain same thickness of investigated alloys on MS. The systematic corrosion investigation of various Cu{sub x}-Sn{sub 100-x} (x = 0-100) alloy depositions on MS substrate were carried out in 0.1 M sulphuric acid medium. Results indicate that the corrosion resistance of the alloy coatings depended on the alloy composition, and the corrosion resistance increased at Cu-Sn alloy deposits in proportion to Sn ratio.

  6. Corrosion resistance of high-performance materials titanium, tantalum, zirconium

    CERN Document Server

    2012-01-01

    Corrosion resistance is the property of a material to resist corrosion attack in a particular aggressive environment. Although titanium, tantalum and zirconium are not noble metals, they are the best choice whenever high corrosion resistance is required. The exceptionally good corrosion resistance of these high–performance metals and their alloys results from the formation of a very stable, dense, highly adherent, and self–healing protective oxide film on the metal surface. This naturally occurring oxide layer prevents chemical attack of the underlying metal surface. This behavior also means, however, that high corrosion resistance can be expected only under neutral or oxidizing conditions. Under reducing conditions, a lower resistance must be reckoned with. Only very few inorganic and organic substances are able to attack titanium, tantalum or zirconium at ambient temperature. As the extraordinary corrosion resistance is coupled with an excellent formability and weldability these materials are very valua...

  7. Evaluation of corrosion behavior of Al-Mg-Li alloys in seawater

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Z.; Abdul Aleem, B.J. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia)

    1996-04-01

    Weldalite 050, a high-strength Al-Mg-Li alloy, was evaluated for its corrosion resistance in deaerated and air saturated Arabian Gulf water to determine its suitability for marine applications. Weight loss and electrochemical studies showed that the alloy had minimum corrosion rates of 1.82 and 4.82 mpy (mils per year), respectively, in deaerated and air saturated Arabian Gulf water with very high total dissolved solids (TDS) content. Weldalite 050 exhibited good resistance to corrosion at velocities up to 3.9 m/s. The formation of Al{sub 2}MgLi, Al-Li, Al{sub 12}Mg{sub 17}, and Al-Li precipitates has a pronounced effect on its corrosion resistance. The corrosion resistance of Weldalite 050 compares favorably with that of alloys 5052 and 5054, wrought alloys 6061 and 6013, and silicon carbide (SiC) reinforced alloys 6061 and 6013.

  8. Effect of ultrasonic cold forging technology as the pretreatment on the corrosion resistance of MAO Ca/P coating on AZ31B Mg alloy

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Lingling, E-mail: daisy_chenlingling@163.com [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China); College of Mechanical and Electrical Engineering, Beijing University of Chemical Technology, Beijing 100029 (China); Gu, Yanhong, E-mail: gu_yanhong@163.com [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China); Liu, Lu, E-mail: liulu@bipt.edu.cn [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China); Liu, Shujing, E-mail: liushujing@bipt.edu.cn [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China); Hou, Binbin, E-mail: sohu19880815@126.com [School of Engineering and Technology, China University of Geosciences, Beijing 100083 (China); Liu, Qi, E-mail: 13521196884@sina.cn [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China); Ding, Haiyang, E-mail: dinghaiyang@bipt.edu.cn [College of Mechanical Engineering, Beijing Institute of Petrochemical Technology, Beijing 102617 (China)

    2015-06-25

    Highlights: • Ultrasonic cold forging technology was used as the pretreatment for MAO coating. • Nano layer with the grain size of 30–80 nm was formed on the UCFT treated surface. • Calcium phosphate contained coating was obtained by MAO process. • The remained nano layer underlying MAO coating could impact the corrosion resistance greatly. - Abstract: A calcium phosphate contained (Ca/P) coating was obtained on AZ31B Mg alloy by micro-arc oxidation (MAO) process under the pretreatment of ultrasonic cold forging technology (UCFT). The surface nanograins were introduced after UCFT pretreatment on AZ31B Mg alloy. Optical microscope (OM) was employed to observe the microstructures of the untreated and UCFT treated samples. Transmission electron microscopy (TEM) and atomic force microscope (AFM) were employed to observe the microstructures of nanograins and the surface roughness of the UCFT treated Mg alloys. The grain size of the UCFT treated Mg alloy is 48.67 nm and the surface roughness is 17.03 nm. The microstructures and the phase compositions of MAO samples were observed and analyzed by scanning electron microscopy (SEM) and X-ray diffraction (XRD), respectively. The XRD results show that the coating include Ca/P phase, including hydroxyapatite (Ca{sub 10}(PO{sub 4}){sub 6}(OH){sub 2}), HA), tertiary calcium phosphate (Ca{sub 3}(PO{sub 4}){sub 2}, TCP) and calcium phosphate dehydrate (CaHPO{sub 4}⋅2H{sub 2}O, DCPD). The hardness of the samples was measured by the micro-hardness tester under the loads of 10 g, 25 g and 50 g. 3D topographies of hardness indenter were characterized by 3D profiler. The immersion tests and potentiodynamic polarization tests were used to evaluate the weight loss rate and corrosion current density in simulated body fluid (SBF). The results show that the corrosion resistance of Ca/P MAO coating on Mg alloy was improved greatly by the pretreatment of UCFT.

  9. Corrosion Behaviour of Zn-10Al-1.5Cu Alloy

    Directory of Open Access Journals (Sweden)

    C. N. Panagopoulos

    2011-01-01

    Full Text Available The corrosion behaviour of Zn-10Al-1.5Cu alloy in NaCl solution was examined. The used NaCl solution concentrations were 1M, 0.3M, and 0.003M for a constant temperature values of 7°C or 25°C or 45°C. The corrosion behaviour of this alloy was investigated under potentiodynamic corrosion conditions. The surface of the corroded alloy specimens was studied with the aid of scanning electron microscopy and X-ray diffraction techniques. It was observed that the increase of NaCl concentration in the corrosion solution for a constant value of temperature led to lower corrosion resistance of the alloy. For a constant value of solution concentration, the increase of solution temperature also led to the decrease of corrosion resistance of the same alloy.

  10. Corrosion Testing of Ni Alloy HVOF Coatings in High Temperature Environments for Biomass Applications

    Science.gov (United States)

    Paul, S.; Harvey, M. D. F.

    2013-03-01

    This paper reports the corrosion behavior of Ni alloy coatings deposited by high velocity oxyfuel spraying, and representative boiler substrate alloys in simulated high temperature biomass combustion conditions. Four commercially available oxidation resistant Ni alloy coating materials were selected: NiCrBSiFe, alloy 718, alloy 625, and alloy C-276. These were sprayed onto P91 substrates using a JP5000 spray system. The corrosion performance of the coatings varied when tested at ~525, 625, and 725 °C in K2SO4-KCl mixture and gaseous HCl-H2O-O2 containing environments. Alloy 625, NiCrBSiFe, and alloy 718 coatings performed better than alloy C-276 coating at 725 °C, which had very little corrosion resistance resulting in degradation similar to uncoated P91. Alloy 625 coatings provided good protection from corrosion at 725 °C, with the performance being comparable to wrought alloy 625, with significantly less attack of the substrate than uncoated P91. Alloy 625 performs best of these coating materials, with an overall ranking at 725 °C as follows: alloy 625 > NiCrBSiFe > alloy 718 ≫ alloy C-276. Although alloy C-276 coatings performed poorly in the corrosion test environment at 725 °C, at lower temperatures (i.e., below the eutectic temperature of the salt mixture) it outperformed the other coating types studied.

  11. Evaluation of hot corrosion resistance of Ni-base alloys using immersion test, coating test and embedding test; Shinseki shiken , tofu shiken , maibotsu shiken ni yoru Ni ki gokin no koon taishoku sei hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Zang, G.; Nishikata, A.; Tsuru, T. [Tokyo Inst. of Tech. (Japan)

    1997-07-20

    Coating test, immersion test and embedding test are usually employed as the methods for testing high temperature corrosion caused by molten salts. In this study, corrosion-resistant properties of twelve kinds of Ni-based alloys are evaluated systematically by immersion, coating and embedding tests using a sulfate, a chloride and a mixture thereof as the molten salts, and the differences of the results obtained by each testing method are examined. The main results of this study are described herein. The reproducibility of said tests is getting higher in an order of embedding test, coating test and immersion test. Especially an extremely high reproducibility is shown by the immersion test. In all corrosive ashes of sulfate, chloride and the mixture thereof, a good correlation is shown between the results of the immersion test and those of the coating test. The results of embedding test are correlated well with those of other tests in sulfate and sulfate/chloride mixture circumstance, while no such a correlation is indicated in chloride. In chloride corrosive ash and sulfate/chloride mixture corrosive ash, the corrosion amounts in coating and embedding tests are rather bigger than that in immersion test. In particular, a large amount of corrosion more than one digital is shown in the alloys with excellent corrosion-resistance. 33 refs., 11 figs., 5 tabs.

  12. PdAgAu alloy with high resistance to corrosion by H2S

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Fernando [Inst. de Investigaciones en Catalisis y Petroquimica, Santa Fe (Argentina); Miller, James B. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept. of Chemical Engineering; National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Gellman, Andrew J. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept. of Chemical Engineering; National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Tarditi, Ana M. [Inst. de Investigaciones en Catalisis y Petroquimica, Santa Fe (Argentina); Fleutot, Benoit [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept. of Chemical Engineering; Kondratyuk, Petro [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept. of Chemical Engineering; National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Cornaglia, Laura M. [Inst. de Investigaciones en Catalisis y Petroquimica, Santa Fe (Argentina)

    2012-12-01

    PdAgAu alloy films were prepared on porous stainless steel supports by sequential electroless deposition. Two specific compositions, Pd83Ag2Au15 and Pd74Ag14Au12, were studied for their sulfur tolerance. The alloys and a reference Pd foil were exposed to 1000 H2S /H2 at 623 K for periods of 3 and 30 hours. The microstructure, morphology and bulk composition of both nonexposed and H2S-exposed samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). XRD and SEM analysis revealed time-dependent growth of a bulk Pd{sub 4}S phase on the Pd foil during H2S exposure. In contrast, the PdAgAu ternary alloys displayed the same FCC structure before and after H2S exposure. In agreement with the XRD and SEM results, sulfur was not detected in the bulk of either ternary alloy samples by EDS, even after 30 hours of H2S exposure. X-ray photoelectron spectroscopy (XPS) depth profiles were acquired for both PdAgAu alloys after 3 and 30 hours of exposure to characterize sulfur contamination near their surfaces. Very low S 2p and S 2s XPS signals were observed at the top-surfaces of the PdAgAu alloys, and those signals disappeared before the etch depth reached ~ 10 nm, even for samples exposed to H2S for 30 hours. The depth profile analyses also revealed silver and gold segregation to the surface of the alloys; preferential location of Au on the alloys surface may be related to their resistance to bulk sulfide formation. In preliminary tests, a PdAgAu alloy membrane displayed higher initial H{sub 2} permeability than a similarly prepared pure Pd sample and, consistent with resistance to bulk sulfide formation, lower permeability loss in H2S than pure Pd.

  13. Comparison of microstructure and corrosion properties of Al-Zn-Mg-Cu alloys 7150 and 7010

    Institute of Scientific and Technical Information of China (English)

    MENG Qing-chang; FAN Xi-gang; REN Shi-yu; ZHANG Xin-mei; ZHANG Bao-you

    2006-01-01

    The influence of coarse Cu-bearing particles, matrix and subgrain boundary precipitates on the stress corrosion susceptibility of the Al-Zn-Mg-Cu alloys was investigated. The strength of 7150 alloy is about 15 MPa higher than that of 7010 alloy.The 7010 alloy exhibits higher resistance to stress corrosion cracking as compared with the 7150 alloy. The coarse Cu-bearing particles are detrimental to the resistance to stress corrosion cracking. The increase of size of matrix and subgrain boundary precipitates decreases the susceptibility of stress corrosion. The anodic dissolution and hydrogen embrittlement govern the cracking process. The severity of stress corrosion cracking is shown to be related to the coarse Cu-bearing particles, matrix and subgrain precipitates in Al-Zn-Mg-Cu alloys.

  14. Investigation on the of effect of self assembling molecules on the corrosion resistance of the 1050 aluminium alloy; Investigacao do efeito de moleculas auto-organizaveis na resistencia a corrosao da liga de aluminio 1050

    Energy Technology Data Exchange (ETDEWEB)

    Szurkalo, Margarida

    2009-07-01

    Surface treatments are widely used to increase the corrosion resistance of metallic materials. Specifically for aluminum and aluminum alloys, treatment with hexavalent chromium is one of the most used, due to its efficiency and ease of application. However, because of environmental restrictions and the high cost involved in the treatments of waste generated in this process, alternative methods for its replacement are necessary. In this context, this study investigated the effect of the surface treatment with self-assembling molecules (SAM) based on phosphonate compounds on the corrosion of the 1050 aluminum alloy. The conditions adopted for the SAM treatment were determined by conductivity and contact angle measurements, besides electrochemical experiments. Electrochemical techniques, specifically: measurement of the open circuit potential (OCP) variation with time, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization curves were used to evaluate the corrosion resistance of the 1050 aluminum alloy exposed to SAM treatment The experimental impedance diagrams were interpreted using equivalent electrical circuit models that simulate film that is formed on the alloy surface. The results of the samples treated with SAM were compared with those of samples either without any treatment or treated with chromatizing conversion coating with Cr(VI) and showed that the first treatment significantly increased the corrosion resistance of the aluminum alloy and approached that of chromatizing with Cr(VI) process. (author)

  15. Corrosion Behavior of Alloy 22 in Chloride Solutions Containing Organic Acids

    Energy Technology Data Exchange (ETDEWEB)

    Carranza, R M; Giordano, C M; Rodr?guez, M A; Rebak, R B

    2005-11-04

    Alloy 22 (N06022) is a nickel based alloy containing alloying elements such as chromium, molybdenum and tungsten. It is highly corrosion resistant both under reducing and under oxidizing conditions. Electrochemical studies such as electrochemical impedance spectroscopy (EIS) were performed to determine the corrosion behavior of Alloy 22 in 1M NaCl solutions at various pH values from acidic to neutral at 90 C. Tests were also carried out in NaCl solutions containing oxalic acid or acetic acid. It is shown that the corrosion rate of Alloy 22 was higher in a solution containing oxalic acid than in a solution of the same pH acidified with HCl. Acetic acid was not corrosive to Alloy 22. The corrosivity of oxalic acid was attributed to its capacity to form stable complex species with metallic cations from Alloy 22.

  16. The effect of heat treatment on the corrosion behaviour of 319 aluminium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Panagopoulos, C.N.; Georgiou, E.P.; Giannakopoulos, K.I. [Laboratory of Physical Metallurgy, National Technical University of Athens, Zografos, Athens (Greece)

    2009-06-15

    The effect of various heat treatments on the corrosion behaviour of 319 T1 cast aluminium alloy was investigated. From this alloy, specimens were heat treated in T5, T6 and two steps solution heat treatment T6 conditions and afterwards were subjected to electrochemical corrosion in a 0.1 M NaCl solution (pH = 12). From the above treatments, T5 heat treatment did not improve the corrosion resistance of the as-received alloy in contrast to T6 heat treatment which improved the corrosion resistance of the same alloy. However, two steps solutionizing T6 treatment showed the best corrosion resistance of the aluminium alloy. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  17. Chemical effects in the Corrosion of Aluminum and Aluminum Alloys. A Bibliography

    Science.gov (United States)

    1976-10-01

    Reduction of corrosion rate of Al cladding on fuel elements in Savannah River reactors by lithium silicate. 1970-30 B.A. Pandya, S.S. Sampat, J.C. Vora...Resistance Of Al Alloys" Statistical study of the corrosion of Al alloys in sea water and in an industrial atm for 5 yrs. 1974-29 A. Soudan Galvano

  18. Investigation on Exfoliation Corrosion and Neutral Salt Spray Corrosion Resistanceof Al-6Mg Alloy with Addition of Scandium

    Institute of Scientific and Technical Information of China (English)

    WANG Yue

    2004-01-01

    Al-6Mg-Sc alloy was prepared by means of melting-casting. Corrosionresistance of Al-6Mg-Sc alloy was studied in exfoliation corrosion and Neutral Salt Spray Test. Microstructure of the Al-6Mg-Sc alloy was investigated by using optical microscope and transmission electron micrograph( TEM ). It was found that additionof scandium served as a potent grain refiner, resulting a homogeneous, dispersed distribution of β-phrase in microstructure of the alloys. The discontinuous precipitation of β-phrase in grain boundaries therefore highly improved corrosion resistance of the alloys.

  19. Effect of niobium addition to the Fe-17% Cr alloy on the resistance to generalized corrosion in sulfuric acid; Efeito da adicao de niobio a liga Fe-17% Cr sobre a resistencia a corrosao generalizada em acido sulfurico

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, Neusa; Wolynec, Stephan

    1992-12-31

    The aim of present work was to investigate the influence of Nb upon the corrosion resistance to o.5 M H2 SO{sub 4} cf 17% Cr ferritic stainless steels, to which it was added in amounts larger than those necessary for the stabilization of interstitial elements. The performance of Fe-17% Cr alloys containing 0.31%, 0.58%, 1.,62% Nb was compared to that of two other Fe-17% Cr alloys containing 0.31%, 0.58% and 1.62% Nb was compared to that of two other Fe-175 Cr alloys, one without additions and another containing 0.93% Nb. Through weight and electrochemical measurements and through morphologic examination of corroded surface it was found that in o.5 M H{sub 2} SO{sub 4} solution the corrosion of these alloys, with the exception of that containing molybdenum, products in two different stages. In the first stage (up to about 60 minutes) the rate practically does not change with time, the lower rates being displayed by alloys containing larger mounts of Nb. In the second stage (for immersion times larger than 60 minutes) the corrosion rate increases with time. the corrosion rate of Mo containing alloy is constant with time so that for longer immersion times this alloy becomes the most resistant. The first stage was discussed in terms of electromechanical properties of Nb and its ability to combine with steel impurities, while the second stage was considered as affected by corrosion products formed on the surface of these alloys after certain time of immersion. (author) 24 refs., 1 fig., 3 tabs.

  20. Effects of Alloying Element Ca on the Corrosion Behavior and Bioactivity of Anodic Films Formed on AM60 Mg Alloys

    Directory of Open Access Journals (Sweden)

    Anawati Anawati

    2016-12-01

    Full Text Available Effects of alloying element Ca on the corrosion behavior and bioactivity of films formed by plasma electrolytic oxidation (PEO on AM60 alloys were investigated. The corrosion behavior was studied by conducting electrochemical tests in 0.9% NaCl solution while the bioactivity was evaluated by soaking the specimens in simulated body fluid (SBF. Under identical anodization conditions, the PEO film thicknesses increased with increasing Ca content in the alloys, which enhanced the corrosion resistance in NaCl solution. Thicker apatite layers grew on the PEO films of Ca-containing alloys because Ca was incorporated into the PEO film and because Ca was present in the alloys. Improvement of corrosion resistance and bioactivity of the PEO-coated AM60 by alloying with Ca may be beneficial for biodegradable implant applications.

  1. The corrosion resistance of Nitinol alloy in simulated physiological solutions Part 2: The effect of surface treatment

    Energy Technology Data Exchange (ETDEWEB)

    Milosev, Ingrid, E-mail: ingrid.milosev@ijs.si [Jozef Stefan Institute, Department of Physical and Organic Chemistry, Jamova 39, SI-1000, Ljubljana (Slovenia); Valdoltra Orthopaedic Hospital, Jadranska c. 31, SI-6280 Ankaran (Slovenia); Kapun, Barbara [Jozef Stefan Institute, Department of Physical and Organic Chemistry, Jamova 39, SI-1000, Ljubljana (Slovenia)

    2012-07-01

    The effect of surface treatment - boiling in water and thermal oxidation at temperatures up to 600 Degree-Sign C - on the corrosion behavior of Nitinol was investigated in simulated Hanks physiological solution using electrochemical polarization methods. Morphological and compositional properties of the modified surfaces were analyzed by scanning electron microscopy, X-ray photoelectron spectroscopy and Auger electron spectroscopy depth profiling. Surface preparation - grinding or polishing - is shown to have a decisive role in the degree of improvement of corrosion properties by surface treatments. Low temperature treatments like boiling in water and thermal oxidation at 100 Degree-Sign C resulted in the formation of oxide layers only a few nanometers thick, and composed mainly of TiO{sub 2} and a small amount of NiO. These layers are well able to protect the underlying Nitinol substrate. Up to 500 Degree-Sign C, surface preparation directly determines the thickness of the oxide scale, as a 20-fold difference in thickness is observed between ground and polished samples. At higher temperatures, the oxide thickness was similar for the two samples. A multilayer structure is observed at all temperatures investigated. The outermost layer at the oxide/air interface is composed of TiO{sub 2} and NiO, while the interior of the oxide scale is composed exclusively of TiO{sub 2}. Oxide layers formed by thermal oxidation at elevated temperatures also improve the corrosion characteristics of Nitinol, especially for polished substrates. - Highlights: Black-Right-Pointing-Pointer The corrosion resistance of Nitinol can be improved by thermal treatment - boiling in water and oxidation in air. Black-Right-Pointing-Pointer The degree of improvement of corrosion resistance is dependent on the surface preparation. Black-Right-Pointing-Pointer For ground samples, boiling in water and thermal treatments up to 400 Degree-Sign C are beneficial. Black-Right-Pointing-Pointer For T < 500

  2. Fatigue - corrosion of endoprosthesis titanium alloys.

    Science.gov (United States)

    Cornet, A; Muster, D; Jaeger, J H

    1979-01-01

    Commercial total hip prostheses often show certain metallurgical faults (porosities, coarse grains, growth dendrites, carbide networks). In order to investigate more accurately the role played by these different parameters in prostheses failure we performed a large number of systematic corrosion, fatigue and fatigue - corrosion tests on these materials and on commercial total hip prostheses. Ultimate strengthes seem to be reached for cast cobalt alloys, whereas titanium alloys, such as Ta 6 V, present very high fatigue limit under corrosion. Thus, rotative bending fatigue - corrosion tests in biological environment provide values about 50 DaN/mm2. This value, is nevertheless appreciably higher than those obtained with stellites and stainless steel. Titanium alloys, because of their mechanical performances, their weak Young's modulus (11000 DaN/mm2) and their relative lightness (4.5. g/cm3), which are associated with a good biocompatibility, seem very promising for permanent implants realisation.

  3. Pitting corrosion resistant austenite stainless steel

    Science.gov (United States)

    van Rooyen, D.; Bandy, R.

    A pitting corrosion resistant austenite stainless steel comprises 17 to 28 wt. % chromium, 15 to 26 wt. % nickel, 5 to 8 wt. % molybdenum, and 0.3 to 0.5 wt. % nitrogen, the balance being iron, unavoidable impurities, minor additions made in the normal course of melting and casting alloys of this type, and may optionally include up to 10 wt. % of manganese, up to 5 wt. % of silicon, and up to 0.08 wt. % of carbon.

  4. Relationship between phase composition and corrosion resistanceof Ni-Ti-Nb based shape memory alloys

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The stability and microstructure of Ni-Ti-Nb based shape memory alloys were investigated after alloyed with elements Zr, Cr and V. In artificial seawater (3.5%NaCl) and physiological solution (5%NaCl+0.1%H2O2), the results show that the alloying elements influence the corrosion behavior of Ni-Ti-Nb alloys. Generally, Zr improves the corrosion resistance of Ni-Ti-Nb alloy, Cr reduces its corrosion resistance and V does not change the property. In order to investigate the reason of the difference,the relation of the phase components and corrosion resistance of Ni-Ti-Nb based shape memory alloys were studied by element analysis and SEM.

  5. Stifling of Crevice Corrosion in Alloy 22

    Energy Technology Data Exchange (ETDEWEB)

    Mon, K G; Gordon, G M; Rebak, R B

    2005-06-08

    Artificially creviced Alloy 22 (N06022) specimens may be susceptible to crevice corrosion in presence of hot chloride containing solutions. The presence of oxyanions in the electrolyte, especially nitrate, may inhibit the nucleation and growth of crevice corrosion. Constant potential tests were performed using tightly creviced specimens of Alloy 22. It was found that crevice corrosion may initiate when a constant potential above the crevice repassivation potential is applied. It was found that as the crevice corrosion nucleated, the current initially increased but later decreased. The net measured current can be converted into penetration following a power law fit of the experimental data. The average power law coefficient ''n'' was found to be 0.439, suggesting that even under constant applied potential crevice corrosion penetration is diffusion controlled.

  6. STIFLING OF CREVICE CORROSION IN ALLOY 22

    Energy Technology Data Exchange (ETDEWEB)

    K.G. Mon; G.M. Gordon; R.B. Rebak

    2005-07-01

    Artificially creviced Alloy 22 (N06022) specimens may be susceptible to crevice corrosion in presence of hot chloride containing solutions. The presence of oxyanions in the electrolyte, especially nitrate, may inhibit the nucleation and growth of crevice corrosion. Constant potential tests were performed using tightly creviced specimens of Alloy 22. It was found that crevice corrosion may initiate when a constant potential above the crevice repassivation potential is applied. It was found that as the crevice corrosion nucleated, the current initially increased but later decreased. The net measured current can be converted into penetration following a power law fit of the experimental data. The average power law coefficient ''n'' was found to be 0.439, suggesting that even under constant applied potential, crevice corrosion penetration is diffusion controlled.

  7. Corrosion of carbon-alloyed iron aluminides

    Indian Academy of Sciences (India)

    M Sen; R Balasubramaniam; A V Ramesh Kumar

    2000-10-01

    The corrosion behaviour of two carbon-alloyed intermetallics of composition Fe–28.1Al–2.1C and Fe–27.5Al–3.7C has been studied and compared with that of binary intermetallics. Potentiodynamic polarization studies indicated that the intermetallics exhibited active–passive behaviour in an acidic solution of pH = 1, whereas they exhibited stable passivity in a buffer solution of pH 8.4. Corrosion rates were also obtained by immersion testing. The variation of corrosion rate as a function of time was similar for both the intermetallics. The variation in corrosion rate as a function of time has been explained based on the observed potentiodynamic polarization behaviour. Scanning electron microscopy of corroded surfaces indicated that the carbon-alloyed intermetallics were susceptible to galvanic corrosion, due to the presence of carbides.

  8. Corrosion behavior of magnesium and magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    I.M.Baghni; WU Yin-shun(吴荫顺); LI Jiu-qing(李久青); ZHANG Wei(张巍)

    2004-01-01

    The automotive industry has crossed the threshold from using magnesium alloys in interior applications such as instrument panels and steering wheels to unprotected environment such as oil pan, cylinder head and wheels. The expanding territory of magnesium leads to new challenges: mainly environmental degradation of the alloys used and how they can be protected. The present critical review is aimed at understanding the corrosion behavior of magnesium and magnesium alloys in industrial and marine environments, and the effect of microstructure, additive elements and inhibitors on the corrosion mechanism.

  9. A study on microstructure and corrosion resistance of ZrO2-containing PEO coatings formed on AZ31 Mg alloy in phosphate-based electrolyte

    Science.gov (United States)

    Zhuang, J. J.; Guo, Y. Q.; Xiang, N.; Xiong, Y.; Hu, Q.; Song, R. G.

    2015-12-01

    ZrO2-containing ceramic coatings formed on the AZ31 Mg alloy were fabricated in an alkaline electrolyte containing sodium phosphate and potassium fluorozirconate (K2ZrF6) by plasma electrolytic oxidation (PEO). X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) techniques were used to study the phase structure and composition of the coatings. It is indicated that the coatings formed in the K2ZrF6-containing electrolyte were composed of MgO, MgF2 and t-ZrO2. Morphological investigation carried out by scanning electron microscopy (SEM) and stereoscopic microscopy, revealed that the uniformity of coatings increased and roughness of coatings decreased after the addition of K2ZrF6. Electrochemical investigation was achieved by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) test. The results showed that the PEO coating formed in K2ZrF6-containing electrolyte exhibited an improved corrosion resistance than that of the coating formed in K2ZrF6-free electrolyte. In addition, the polarization and EIS tests results both showed that the suitable concentration (2.5 g/l) of K2ZrF6 is of significant ability to improve the corrosion resistance of coatings. However, 5 g/l and 10 g/l K2ZrF6 has a negative effect on improving the corrosion resistance of PEO coatings compared with the coating formed in 2.5 g/l K2ZrF6-containing electrolyte.

  10. Investigation of the corrosion resistance of Ti-13Nb-13Zr alloy by electrochemical techniques and surface analysis; Investigacao da resistencia a corrosao da liga Ti-13Nb-13Zr por meio de tecnicas eletroquimicas e de analise de superficie

    Energy Technology Data Exchange (ETDEWEB)

    Assis, Sergio Luiz de

    2006-07-01

    In this work, the in vitro corrosion resistance of the Ti-13Nb-13Zr alloy, manufactured at a national laboratory, and used for orthopedic applications, has been investigated in solutions that simulate the body fluids. The electrolytes used were 0.9 % (mass) NaCl, Hanks' solution, a culture medium (MEM), and the two last electrolytes, without and with addition of hydrogen peroxide. The aim of peroxide addition was to simulate the conditions found when inflammatory reactions occur due to surgical procedures. The corrosion resistance of alloys commercially in use as biomaterials, Ti-6Al-7Nb and Ti-6Al-4V, as well as of the pure titanium (Ti-cp), was also studied for comparison with the Ti-13Nb-13Zr alloy. The corrosion resistance characterization was carried out by electrochemical and surface analysis techniques. The electrochemical tests used were: open circuit potential measurements as a function of tim; potentiodynamic polarization; and electrochemical impedance spectroscopy (EIE). The impedance experimental diagrams were interpreted using equivalent electric circuits that simulate an oxide film with a duplex structure composed of an internal and compact, barrier type layer, and an external porous layer. The results showed that the corrosion resistance is due mainly to the barrier type layer. The titanium alloys and the Ti-cp showed high corrosion resistance in all electrolytes used. The oxides formed on the Ti-13Nb-13Zr, either naturally or during immersion in MEM ar Hank's solution was characterized by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (MEV). The results showed that the presence of hydrogen peroxide in MEM promotes the growth of the porous layer and incorporation of mineral ions, besides favouring hydroxyapatite formation. The cytotoxicity of the Ti-13Nb-13Zr alloy was also evaluated and it was shown to be non-toxic. (author)

  11. Corrosion of friction stir welded magnesium alloy AM50

    Energy Technology Data Exchange (ETDEWEB)

    Zeng Rongchang [School of Material Science and Engineering, Chongqing University of Technology, Xingshenglu Rd. 4, Chongqing 400050 (China)], E-mail: rczeng2001@yahoo.com.cn; Chen Jun [School of Material Science and Engineering, Chongqing University of Technology, Xingshenglu Rd. 4, Chongqing 400050 (China); Dietzel, Wolfgang; Zettler, Rudolf; Santos, Jorge F. dos [GKSS-Forschungszentrum Geesthacht GmbH, Max Planck Strasse 1, 21502 Geesthacht (Germany); Lucia Nascimento, M. [Technische Universitaet Berlin, Fachgebiet Werkstofftechnik, Strasse des 17. Juni 135, 10623 Berlin (Germany); Kainer, Karl Ulrich [GKSS-Forschungszentrum Geesthacht GmbH, Max Planck Strasse 1, 21502 Geesthacht (Germany)

    2009-08-15

    The microstructure of a friction stir welded magnesium alloy AM50 was examined by means of optical light microscopy. The chemical composition, particularly the iron content, and morphology of the oxide film were analyzed and discerned via auger electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS). Corrosion behaviour of the welds and base materials were investigated by virtue of neutral salt spray tests and potentiodynamic polarization measurements in conventional cells and in a mini cell. The results demonstrate that minor increases in iron concentration as might be speculated to occur as a consequence of tool/work piece interaction during the welding process on the corrosion resistance of the weld can be ignored. The corrosion morphology was predominantly influenced by the distribution of the Mg{sub 17}Al{sub 12} phase. Here, it was also found that the corrosion resistance of the friction stir weld varied in response to changes in the joint microstructure.

  12. A rapid stress-corrosion test for aluminum alloys

    Science.gov (United States)

    Helfrich, W. J.

    1968-01-01

    Stressed alloy specimens are immersed in a salt-dichromate solution at 60 degrees C. Because of the minimal general corrosion of these alloys in this solution, stress corrosion failures are detected by low-power microscopic examination.

  13. Galvanic corrosion of rare earth modified AM50 and AZ91D magnesium alloys coupled to steel and aluminium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Mohedano, M.; Arrabal, R.; Pardo, A.; Paucar, A.; Merino, M. C.; Matykina, E.; Mingo, B.; Garces, G.

    2014-04-01

    Electrochemical and gravimetric measurements were used to examine the effects of neodymium and gadolinium additions on the galvanic corrosion behaviour of AM50 and AZ91D magnesium alloys coupled to A 570 Gr 36 carbon steel and AA2011-AA6082 aluminium alloys. Rare earth modified alloys showed Al{sub 2}Nd/Al{sub 2}Gd and Al-Mn-Nd/Al-Mn-Gd intermetallics, reduced area fraction of {beta}-Mg{sub 1}7Al{sub 1}2 phase and increased corrosion resistance due to increased surface passivity and suppression of micro-galvanic couples. Neodymium and gadolinium additions improved the galvanic corrosion resistance of AM50 alloy, but were less effective in case of the AZ91D alloy. The AA6082 alloy was the most compatible material and the AA2011 alloy was the least compatible. (Author)

  14. Corrosion Characteristics of Ti-29Nb-xHf Ternary Alloy for Biomaterials

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sun Young; Choi, Han Chul [Chosun Univ., Kwangju (Korea, Republic of)

    2015-12-15

    The Cp-Ti and Ti-6Al-4V alloys were widely used for dental materials due to their mechanical properties and good corrosion resistance. However, Cp-Ti was known as bio-inert materials, Ti-6Al-4V alloy has a problem such as high Young modulus, potential loss of the surrounding bone, and to the release of potentially toxic ions from the alloy. To overcome this problem, Ti alloys containing Nb and Hf elements have been used for biomaterials due to low toxicity and high corrosion resistance. Especially, alloying element of Nb was known as β phase stabilizer. The β phase alloy was widely used to replace currently used implant materials. The corrosion resistances of Ti-29Nb-xHf ternary alloys were dependent on Hf content in oral environment solution.

  15. Effect of carburization on electrochemical corrosion behaviours of TiAl alloy

    Energy Technology Data Exchange (ETDEWEB)

    Liao, Cuijiao [State Key Laboratory for Powder Metallurgy, Central South University, Changsha, Hunan 410083 (China); Hunan University of Technology, Zhuzhou, Hunan 412000 (China); He, Yuehui, E-mail: yuehui@mail.csu.edu.cn [State Key Laboratory for Powder Metallurgy, Central South University, Changsha, Hunan 410083 (China); Yang, Junsheng; Nan, Bo; Liu, Xinli [State Key Laboratory for Powder Metallurgy, Central South University, Changsha, Hunan 410083 (China)

    2013-04-20

    Highlights: ► The functional complex ceramic phase Ti{sub 2}AlC was formed by pack carburizing. ► The anodic polarization curve of the carburized TiAl alloy shows a larger passivation interval (about 1.246 V). ► The polarization resistance of the carburized TiAl alloy is at least seventeen times higher, compared to the untreated TiAl alloy. ► The corroded surface of the carburized TiAl alloy was covered with passive film. -- Abstract: Electrochemical corrosion behaviours of the untreated and the carburized of Ti-46.5Al (mol %) alloy were investigated. X-ray diffractometry (XRD) and scanning electron microscopy (SEM) were applied to characterize the carburized layer. Potentiodynamic polarization curve, electrochemical impedance spectroscopy (EIS) and SEM morphology of the corroded surface were used to evaluate corrosion resistance of both carburized and untreated TiAl alloy in 1 mol/L HCl. The outer layer of the carburized TiAl alloy is a continuous Ti{sub 2}AlC scale. Polarization curve and electrochemical impedance spectroscopy (EIS) of the carburized TiAl alloy present a nobler corrosion potential, a more positive pitting potential and a higher polarization resistance, respectively, compared with the untreated sample. After anodic corrosion or immersion corrosion, a deposited layer can be observed on the surface of the carburized titanium aluminide alloy. By contrast, pitting and crevasse corrosion occur on the surface of the untreated TiAl alloy after anodic corrosion and some corrosion products and slight corrosion appear on the surface of the untreated TiAl alloy after immersion corrosion.

  16. Corrosion resistant neutron absorbing coatings

    Science.gov (United States)

    Choi, Jor-Shan [El Cerrito, CA; Farmer, Joseph C [Tracy, CA; Lee, Chuck K [Hayward, CA; Walker, Jeffrey [Gaithersburg, MD; Russell, Paige [Las Vegas, NV; Kirkwood, Jon [Saint Leonard, MD; Yang, Nancy [Lafayette, CA; Champagne, Victor [Oxford, PA

    2012-05-29

    A method of forming a corrosion resistant neutron absorbing coating comprising the steps of spray or deposition or sputtering or welding processing to form a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material. Also a corrosion resistant neutron absorbing coating comprising a composite material made of a spray or deposition or sputtering or welding material, and a neutron absorbing material.

  17. Corrosion Resistance of Cordierite-Modified Light MMCs

    Science.gov (United States)

    Szewczyk-Nykiel, A.; Długosz, P.; Darłak, P.; Hebda, M.

    2017-05-01

    Composites are one of the fastest developing materials. Research is particularly intensive in case of light metal alloys due to i.a. economic and environmental aspects. One of the innovative solutions is production of the metal matrix composites (MMC) by adding the cordierite ceramics obtained from fly ashes to magnesium alloys. In addition to obtaining new-generation materials with improved mechanical properties, also the waste is utilized which has a significant environmental and economic importance. In order to select the suitable operating conditions for such alloys, their corrosion resistance must be determined. This paper presents the results of corrosion resistance tests of AM60 magnesium alloy matrix composites reinforced with cordierite ceramics. The following issues were examined: (1) impact of the volume fraction of cordierite ceramics, 2 or 4 wt.%; (2) impact of surface roughness (two variants of surface treatment); and (3) impact of heat treatment on corrosion resistance of obtained composites. The results were compared with data recorded for the base AM60 alloy (which surface treatment was identical as of the composites). Moreover, the XRD and microanalysis of the chemical compositions by EDS method were applied to determine phases occurring in the investigated composites. Furthermore, the XRD was also performed in order to identify the corrosion products on the surface of the material. The test results indicate that the alloy reinforced with 2 wt.% addition of cordierite ceramics had the best corrosion resistance. It was also presented that surface and heat treatment affect the obtained results.

  18. Selective dissolution in copper-tin alloys: Formation of corrosion- resistant patina on ancient Chinese bronze mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Taube, M. [State Univ. of New York, Stony Brook, NY (United States). Dept. of Materials Science and Engineering]|[Brookhaven National Lab., Upton, NY (United States); Davenport, A.J. [Brookhaven National Lab., Upton, NY (United States); King, A.H. [State Univ. of New York, Stony Brook, NY (United States). Dept. of Materials Science and Engineering; Chase, T. III [Smithsonian Institution, Washington, D.C. (United States) Freer Gallery of Art, Dept. of Conservation and Scientific Research

    1996-07-01

    Many ancient Chinese bronze mirrors have survived with a patina that leaves the delicate relief surface decorations intact. The microstructure of these ancient mirrors is two-phase and consists of acicular {alpha}-phase (Cu-rich) regions encased in a {delta}-phase (Sn-rich) matrix. At the surface, there is evidence of selective dissolution of the ct phase; the cc-phase regions are replaced pseudomorphically by a mineral product with the {delta} phase remaining metallic. Electrochemical polarization has been used to drive the copper dealloying process in modem, cast bronze. Synchrotron x-ray diffraction was employed to compare the ancient samples with those that were prepared potentiostatically. Poorly crystallized tin oxide (SnO{sub 2}) was found in the {alpha} replacement products of both sample types. The corrosion-resistance of the potentiostatically-treated bronze samples was tested by atmospheric exposure. Comparison with exposed, untreated samples indicated that the treatment was protective.

  19. Corrosion-resistant coating development

    Energy Technology Data Exchange (ETDEWEB)

    Stinton, D.P.; Kupp, D.M.; Martin, R.L. [Oak Ridge National Lab., TN (United States)

    1997-12-01

    SiC-based heat exchangers have been identified as the prime candidate material for use as heat exchangers in advanced combined cycle power plants. Unfortunately, hot corrosion of the SiC-based materials created by alkali metal salts present in the combustion gases dictates the need for corrosion-resistant coatings. The well-documented corrosion resistance of CS-50 combined with its low (and tailorable) coefficient of thermal expansion and low modulus makes CS-50 an ideal candidate for this application. Coatings produced by gelcasting and traditional particulate processing have been evaluated.

  20. 3GPa压力处理对7075铝合金耐腐蚀性的影响%Effect of 3GPa Pressure Treatment on Corrosion Resistance of 7075 Alloy

    Institute of Scientific and Technical Information of China (English)

    李敏

    2013-01-01

    The corrosion rate and electrochemical data of 7075 alloy before and after 3 GPa pressure treatment in 3.5%NaClsolution were measured,and the microstructure was observed.Based on the results,the effects of 3 GPa pressure treatment on the corrosion resistance of the Al alloy was investigated.The results show that 3 GPa pressure treatment can make the corrosion potential move positively,while the corrosion rate reduces,and the corrosion resistance of the alloy improves.%通过对3 GPa压力处理前后7075铝合金在3.5%NaCl溶液中腐蚀速率和电化学参数的测试,结合金相组织的观察,探讨了3 GPa压力处理对7075铝合金耐腐蚀性的影响.结果表明:3 GPa压力处理能使该合金的腐蚀电位正移,腐蚀速率减小,耐腐蚀性提高.

  1. Corrosion of dental alloys in artificial saliva with Streptococcus mutans.

    Science.gov (United States)

    Lu, Chunhui; Zheng, Yuanli; Zhong, Qun

    2017-01-01

    A comparative study of the corrosion resistance of CoCr and NiCr alloys in artificial saliva (AS) containing tryptic soy broth (Solution 1) and Streptococcus mutans (S. mutans) species (Solution 2) was performed by electrochemical methods, including open circuit potential measurements, impedance spectroscopy, and potentiodynamic polarization. The adherence of S. mutans to the NiCr and CoCr alloy surfaces immersed in Solution 2 for 24 h was verified by scanning electron microscopy, while the results of electrochemical impedance spectroscopy confirmed the importance of biofilm formation for the corrosion process. The R(QR) equivalent circuit was successfully used to fit the data obtained for the AS mixture without S. mutans, while the R(Q(R(QR))) circuit was found to be more suitable for describing the biofilm properties after treatment with the AS containing S. mutans species. In addition, a negative shift of the open circuit potential with immersion time was observed for all samples regardless of the solution type. Both alloys exhibited higher charge transfer resistance after treatment with Solution 2, and lower corrosion current densities were detected for all samples in the presence of S. mutans. The obtained results suggest that the biofilm formation observed after 24 h of exposure to S. mutans bacteria might enhance the corrosion resistance of the studied samples by creating physical barriers that prevented oxygen interactions with the metal surfaces.

  2. Resistance to corrosion by water at high temperatures of Al-Fe-Ni alloy after prolonged heat treatment. Influence of Ti and Zr additions; Tenue a la corrosion par l'eau a haute temperature de l'alliage Al-Fe-Ni apres des chauffages de longue duree. Influence des additions Ti et Zr

    Energy Technology Data Exchange (ETDEWEB)

    Lelong, P.; Moisan, J.; Herenguel, J. [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires; Centre de Recherches de la Ste des Trefileries et Laminoirs du Havre, 92 - Antony (France)

    1960-07-01

    The influence of titanium and zirconium additions on the heterogeneity texture of Al-Fe-Ni alloys, and the resultant effect on their corrosion resistance, is briefly recalled. The present article records the results of corrosion tests on these alloys after prolonged heat treatment. Without additions, the eutectic structure of the basis alloy is subject to a coalescence, which results in a deterioration of corrosion resistance. This effect applies equally to the as-cast and to the wrought conditions. The addition of titanium or zirconium retards this deterioration very considerably, both for the as-cast and wrought alloys. (author) [French] Apres un rappel de l'influence la texture d'heterogeneite sur la tenue a la corrosion, et du role joue par les additions de titane et de zirconium sur cette texture, il est rapporte dans le present travail les resultats d'essais de corrosion apres ces chauffages de longue duree. Pour l'alliage de base, la coalescence de l'eutectique dans l'etat de fonderie comme dans l'etat corroye, suivie micrographiquement, s'accompagne d'une degradation sensible de la tenue a la corrosion. Les additions de zirconium et de titane retardent tres fortement cette degradation, qu'il s'agisse encore de la texture de fonderie ou de celle de corroyage. (auteur)

  3. Corrosion Resistance of Nickel Electroplating on Aluminum Alloy%铝合金表面电镀镍的耐腐蚀性能

    Institute of Scientific and Technical Information of China (English)

    韩登峰; 鲁道荣; 周洋

    2012-01-01

    Nickel coating was electroplated on the surface of aluminum alloy. The effect of the temperature of solution and current density and solution pH on the corrosion resistance of the coating were studied. The Nickel coating were obtained under the optimum conditions. The corrosive medium was 3.50 % sodium chloride solution. The corrosion resistance of nickel coating was researched by steady-state anodic polarization curves. The morphology of apparent and microstructure change before and after corrosion of the nickel coating were researched by SEM and XRD. The results indicated that the temperature at 50 ℃, the current density 30 mA/cm^2 , the solution pH value 3. 82 is the best process conditions. XRD tests showed that the structure of nickel coating is cubic crystal system, and crystal preferred orientation (111) unchanged before and after corrosion, but texture coefficient of (111) was increased from 35.35% to 61.7aN. and that the orientation (111) had better corrosion resistance was showed. SEM test showed that the semi-bright nickel plating with uniform and compact was prepared under the optimum conditions. It had good corrosion resistance.%在铝合金表面电镀镍,考察镀液温度、电流密度和镀液pH值等因素对镀层耐蚀性能的影响,获得最佳电镀条件下的镍镀层.选择3.50%NaCl溶液作为腐蚀介质,采用稳态阳极极化曲线法研究镀层的耐蚀性能.用SEM和XRD研究镍镀层在腐蚀前后的微观结构和表观形貌的变化.结果表明镀镍的最佳工艺条件为温度50℃、电流密度30mA/cm2、镀液pH值3.82.XRD测试表明镍镀层的结构为立方晶系,晶面择优取向为(111),腐蚀前后晶面择优取向不变,但(111)晶面的织构系数由35.35%增至61.73%,说明低指数晶面(111)具有较好的耐蚀性能.SEM测试表明最佳条件下制备的半光亮镍镀层均匀致密,具有较好的耐腐蚀性能.

  4. Sodium corrosion behavior of austenitic alloys and selective dissolution of chromium and nickel

    Science.gov (United States)

    Suzuki, T.; Mutoh, I.; Yagi, T.; Ikenaga, Y.

    1986-06-01

    The corrosion behavior of six austenitic alloys and reference Type 316 stainless steel (SS) has been examined in a flowing sodium environment at 700°C for up to about 4000 h. The alloys with a range of nickel content between ~ 15 and 43 wt% were designed and manufactured with an expectation of improved swelling resistance during fast neutron irradiation, compared to reference Type 316 SS. The corrosion loss of the alloys at zero downstream position and the concentrations of chromium, nickel and iron in the surface region were determined as a function of corrosion time. The selective dissolution of nickel and chromium played an important role in sodium corrosion of the alloys. During the initial period, accelerated corrosion took place and selective dissolution of chromium and nickel proceeded at a rapid rate. During the subsequent period, the overall corrosion rate and depletion of chromium and nickel decreased with increasing time until the corrosion rate and the surface concentrations of chromium, nickel and iron, which depended on composition of the alloys, reached the steady-state after about 2000 h. Also, the corrosion rate increased with increasing original nickel content of the alloys. Microstructural examination revealed surface attack of the alloys with higher nickel contents, in particular for the two precipitation strengthened Fe-Ni alloys. The alloys showed a trend of increasing carbon and nitrogen contents.

  5. Effect of laser surface melting on microstructure and corrosion characteristics of AM60B magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Cancan [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100039 (China); Liang, Jun, E-mail: jliang@licp.cas.cn [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Zhou, Jiansong, E-mail: jszhou@licp.cas.cn [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Wang, Lingqian [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); Li, Qingbiao [State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou 730000 (China); University of Chinese Academy of Sciences, Beijing 100039 (China)

    2015-07-15

    Highlights: • Laser surface melting was used on AM60B Mg alloy. • The microstructure, composition and corrosion behavior of the as-received and LSM treated specimens were compared. • The laser treated alloy exhibited better corrosion resistance than the as-received one in the long term. • A model of two different corrosion mechanisms was established. - Abstract: Surface modification of laser surface melting (LSM) was applied to the AM60B magnesium alloy using a 10 kW continuous-wave CO{sub 2} laser. The microstructure, composition and corrosion resistance of AM60B magnesium alloy after LSM treatment were investigated by using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDS), X-ray diffraction (XRD) and corrosion tests, respectively. Results showed that the LSM treatment produced a continuous and homogeneous modified layer with refined grains, enriched Al element and redistributed intermetallic compounds on AM60B alloy. The corrosion resistance of the AM60B alloy was enhanced by the LSM treatment. The enhancement of the corrosion resistance was mainly attributed to the reduced corrosion susceptibility of Al enriched α-Mg matrix and the barrier effect of uniformly distributed β-phase of the LSM modified layer.

  6. The Corrosion Behaviour of WC-Co-Ru Alloys in Aggressive Chloride Media

    Directory of Open Access Journals (Sweden)

    J. H. Potgieter

    2014-01-01

    Full Text Available Hardmetals possess excellent wear resistance, making them suitable alloys in several industrial applications. Mine waters with both dissolved chloride and sulphate salts can be severely corrosive and can limit the application of hardmetal tools in the mining industry. Ru additions to these alloys can refine and improve selected mechanical properties, but its influence on the corrosion resistance is unknown. A series of WC-Co-Ru alloys was evaluated in different chloride containing media to investigate their corrosion resistance. Standard electrochemical corrosion tests, chronoamperometric measurements, and surface analyses with Raman spectroscopy were conducted. An increasing amount of Ru improves the corrosion resistance of all the alloys. The effect is not as dramatic as that observed with stainless steels containing Ru in corrosive media. In both corrosive media Ru decreased the cathodic Tafel constant and has a retarding influence on the cathodic part of the corrosion reaction. Raman analyses indicated the presence of tungsten oxide, hydrated tungsten oxide compounds, and CoO and Co3O4 formed on the alloy surfaces during the corrosion process.

  7. Corrosion Behaviour of A380 Aluminiun Alloy by Semi-Solid Rheocasting

    Science.gov (United States)

    Forn, A.; Rupérez, E.; Baile, M. T.; Campillo, M.; Menargues, S.; Espinosa, I.

    2007-04-01

    A comparative study was performed on the corrosion behavior of a component of A380 aluminium alloy obtained by Semi-Solid Rheocasting (SSR). The effect of heat treatments T5 and T6 on corrosion resistance was compared with components without heat treatment by SSR processes. Corrosion studies were performed using an acetic acid salt spray test, impedance measurements and polarization curves using a 3,5%Na Cl test solution. The corrosion progress is described by micrographic analysis.

  8. Through-thickness inhomogeneity of localized corrosion in 7050-T7451 Al alloy thick plate

    Institute of Scientific and Technical Information of China (English)

    丰雷; 潘清林; 韦莉莉; 黄志其; 刘志铭

    2015-01-01

    The through-thickness corrosion inhomogeneity of 7050-T7451 Al alloy thick plate was studied using immersion tests, potentiodynamic polarization, electrochemical impedance spectroscopy (EIS), slow strain rate testing (SSRT) technique combined with optical microscopy (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results show that the through-thickness corrosion resistance is ranked in the order of T/2>surface>T/4. And the 75 mm-thick 7050 alloy plate presents better corrosion resistance than the 35 mm-thick plate. The results are discussed in terms of the combined effect of recrystallization and cooling rate in quenching. Alloy with lower volume fraction of recrystallization and smaller grain aspect ratio displays better corrosion resistance. The lower corrosion resistance caused by the slower cooling rate results from the higher coverage rate of grain boundary precipitates and larger width of precipitate free zone.

  9. Stress-corrosion cracking of titanium alloys.

    Science.gov (United States)

    Blackburn, M. J.; Feeney, J. A.; Beck, T. R.

    1973-01-01

    In the light of research material published up to May 1970, the current understanding of the experimental variables involved in the stress-corrosion cracking (SCC) behavior of titanium and its alloys is reviewed. Following a brief summary of the metallurgy and electrochemistry of titanium alloys, the mechanical, electrochemical, and metallurgical parameters influencing SCC behavior are explored with emphasis on crack growth kinetics. Macro- and microfeatures of fractures are examined, and it is shown that many transgranular SCC failures exhibit morphological and crystallographic features similar to mechanical cleavage failures. Current SCC models are reviewed with respect to their ability to explain the observed SCC behavior of titanium and its alloys. Possible methods for eliminating or minimizing stress corrosion hazards in titanium or titanium alloy components are described.

  10. Influence of Friction Stir Welding on Corrosion Properties of Aw-7020M Alloy in Sea Water

    Directory of Open Access Journals (Sweden)

    Dudzik K.

    2015-03-01

    Full Text Available Friction Stir Welding (FSW, provides an alternative to MIG and TIG welding methods for joining aluminium alloys. The article presents the results of electrochemical corrosion resistance test of alloy AW- 7020M and its joints welded by FSW. The study was performed using the method of electrochemical impedance spectroscopy (EIS. Impedance spectroscopy studies showed that both, the FSW welded joint and base material AW-7020M has a good resistance to electrochemical corrosion in sea water environment, wherein the welded joint has a higher susceptibility to this type of corrosion. Research has indicated the desirability of applying the FSW method for joining AW-7020M alloy in shipbuilding industry.

  11. Influence of the Environment on the General Corrosion Rate of Alloy 22 (N06022)

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; Crook, P

    2004-04-19

    Nickel (Ni) can dissolve a large amount of alloying elements while still maintaining its desirable austenitic microstructure. The resulting alloys are generally divided in families depending on the type of alloying elements they contain. Each one of these families is aimed to specific applications. Corrosive environments in industrial applications are generally divided for example in reducing acids, oxidizing acids, contaminated acids, caustic environments, oxidizing salts, etc. Depending on the application and the environment (electrolyte composition and temperature) several or single alloys may be recommended to fabricate components. The Nichromium-molybdenum (Ni-Cr-Mo) series contains a balanced selection of beneficial alloying elements so it can handle a variety of aggressive environments. By design, Alloy 22 or N06022 is one of the most versatile corrosion resistant nickel alloys since it has an outstanding corrosion resistance both in reducing and oxidizing conditions.

  12. Corrosion of Metal-Matrix Composites with Aluminium Alloy Substrate

    Directory of Open Access Journals (Sweden)

    B. Bobic

    2010-03-01

    Full Text Available The corrosion behaviour of MMCs with aluminium alloy matrix was presented. The corrosion characteristics of boron-, graphite-, silicon carbide-, alumina- and mica- reinforced aluminium MMCs were reviewed. The reinforcing phase influence on MMCs corrosion rate as well as on various corrosion forms (galvanic, pitting, stress corrosion cracking, corrosion fatique, tribocorrosion was discussed. Some corrosion protection methods of aluminium based MMCs were described

  13. Co-Fe based amorphous alloy corrosion resistance: Effects of composition and heat treatment; Effetto della composizione e dei trattamenti termici sulla resistenza alla corrosione di leghe amorfe a base di ferro e cobalto

    Energy Technology Data Exchange (ETDEWEB)

    Angelini, E.; Antonione, C.; Baricco, M.; Rosalbino, F.; Zucchi, F.

    1990-12-31

    This paper examines the influence of composition and heat treatment on the corrosion resistance, in a 1.5 pH solution of Na/sub 2/SO/sub 4/ 0.05M + H/sub 2/SO/sub 4/ 0.05M, of series of iron based amorphous alloys with increasing cobalt content, i.e., Fe/sub 80-x/Co/sub x/B/sub 10/Si/sub 10/ with values of x = 0,30,80. The heat treatments were carried out in an argon atmosphere at increasing durations (30, 60, 120 and 240 min) and temperatures (350, 400, 450, and 500 degrees C). Independently of the type of heat treatment, it was observed that the corrosion resistance increases with increasing cobalt concentration. In comparing samples having the same composition, corrosion resistance deteriorated with increasing heat treatment duration times and temperatures.

  14. Review of Corrosion Modes for Alloy 22 Regarding Lifetime Expectancy of Nuclear Waste Containers

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; Estill, J C

    2002-11-15

    Alloy 22 (UNS N06022) was selected to fabricate the corrosion resistant outer barrier of a two-layer waste package container for nuclear waste at the designated repository site in Yucca Mountain in Nevada (USA). A testing program is underway to characterize and quantify three main modes of corrosion that may occur at the site. Current results show that the containers would perform well under general corrosion, localized corrosion and environmentally assisted cracking (EAC). For example, the general corrosion rate is expected to be below 100 nm/year and the container is predicted to be outside the range of potential for localized corrosion and environmentally assisted cracking.

  15. Corrosion-resistant sulfur concretes

    Science.gov (United States)

    McBee, W. C.; Sullivan, T. A.; Jong, B. W.

    1983-04-01

    Sulfur concretes have been developed by the Bureau of Mines as construction materials with physical and mechanical properties that suit them for use in acid and salt corrosive environments where conventional concretes fail. Mixture design methods were established for preparing sulfur concretes using different types of aggregates and recently developed mixed-modified sulfur cements. Bench-scale testing of the sulfur concretes has shown their potential value. Corrosion resistance, strength, and durability of sulfur concrete are superior to those of conventional materials. Field in situ evaluation tests of the sulfur concretes as replacement for conventional concrete materials are in progress in corrosive areas of 24 commercial chemical, fertilizer, and metallurgical plants.

  16. Peculiar high temperature corrosion of martensite alloy under impact of Estonian oil shale fly ash

    Energy Technology Data Exchange (ETDEWEB)

    Tallermo, H.; Klevtsov, I. [Thermal Engineering Department of Tallinn Technical University, Tallinn (Estonia)

    1998-12-31

    The superheaters` surfaces of oil shale steam boiler made of pearlitic and austenitic alloys, are subject to intensive corrosion, mainly due to presence of chlorine in external deposits. The applicability of martensitic alloys X1OCrMoVNb91 and X20CrMoV121 for superheaters is examined here and empirical equations allowing to predict alloys` corrosion resistance in the range of operational temperatures are established. Alloy X1OCrMoVNb91 is found been most perspective for superheaters of boilers firing fossil fuel that contain alkaline metals and chlorine. The abnormal dependence of corrosion resistance of martensitic alloys on temperature is revealed, namely, corrosion at 580 deg C in presence of oil shale fly ash is more intensive than at 620 deg C. (orig.) 2 refs.

  17. Comparative corrosion study of Ag–Pd and Co–Cr alloys used in dental applications

    Indian Academy of Sciences (India)

    D Mareci; D Sutiman; A Cailean; G Bolat

    2010-08-01

    The electrochemical behaviour of two Ag–Pd alloys (Unique White and Paliag) used in dental prosthetics construction for crowns and bridges and one Co–Cr alloy (Vitallium 2000) was studied in artificial saliva using the polarization curves and electrochemical impedance spectroscopy (EIS). The corrosion resistance was evaluated by means of the corrosion currents value and by coulometric analysis. The open circuit potential of Ag–Pd are attributed to dealloying followed by surface enrichment with Ag and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. Our results have shown that these alloys have a somewhat good corrosion resistance in artificial saliva. The corrosion current densities of Unique White and Vitallium 2000 alloys were very low (∼100 nA/cm2). For Ag–Pd alloys, when increasing the content of Cu, corrosion resistance decreases. The passivation of all samples occurred spontaneously at the open circuit potential. The electrochemical properties of the spontaneously passivated electrodes at the open circuit potential were studied by EIS. The polarization resistance (p) and the electrode capacitance (dl) were determined. The polarization resistance of all the samples increases with the immersion time. The polarization resistances are largest for Unique White (Ag–Pd) and Vitallium 2000 (Co–Cr) alloys. Because the electrochemical behaviour of the Co–Cr alloy was compared with that of Ag–Pd alloy, this type of alloy may be a suitable alternative for use in the manufacture of fixed dental prostheses. The present study, though limited, has shown that electrochemical characteristics can be used to identify such alloys. Knowledge of the in vitro corrosion behaviour of these alloys may lead to better understanding of any biologically adverse effects in vitro.

  18. Stress corrosion cracking of several high strength ferrous and nickel alloys

    Science.gov (United States)

    Nelson, E. E.

    1971-01-01

    The stress corrosion cracking resistance of several high strength ferrous and nickel base alloys has been determined in a sodium chloride solution. Results indicate that under these test conditions Multiphase MP35N, Unitemp L605, Inconel 718, Carpenter 20Cb and 20Cb-3 are highly resistant to stress corrosion cracking. AISI 410 and 431 stainless steels, 18 Ni maraging steel (250 grade) and AISI 4130 steel are susceptible to stress corrosion cracking under some conditions.

  19. Study on hemocompatibility and corrosion behavior of ion implanted TiNi shape memory alloy and Co-based alloys.

    Science.gov (United States)

    Liang, Chenghao; Huang, Naibao

    2007-10-01

    Biomedical TiNi shape memory alloy and Co-based alloys were ion implanted, and corrosion resistance and hemocompatibility of these had been investigated with electrochemical method, dynamic clotting time, and hemolysis rate tests. The results indicated that the electrochemical stability and anodic polarization behavior of the materials were improved significantly after ion implantation. When TiNi, Co-based alloys were implanted Mo + C and Ti + C, respectively, the corrosion potentials were enhanced more than 200 mV, passive current densities decreased, and passive ranges were broadened. Dynamic clotting time of the ion implanted substances was prolonged and hemolysis rate decreased. All the results pointed out that corrosion resistance and hemocompatibility of the alloys were improved by ion implantation, and effects of dual implantation was better than that of C single implantation. X-ray diffraction analysis of the alloys after dual implantation revealed that TiC, Mo(2)C, Mo(9)Ti(4), and Mo appeared on the surface of TiNi alloy, and CoC(x), Co(3)Ti, TiC, and TiO on the surface of Co-based alloys. These phases dispersing on the alloy surface formed amorphous film, prevented dissolving of alloy elements and improved the corrosion resistance and hemocompatibility of the alloys.

  20. Stress corrosion cracking of titanium alloys

    Science.gov (United States)

    Statler, G. R.; Spretnak, J. W.; Beck, F. H.; Fontana, M. G.

    1974-01-01

    The effect of hydrogen on the properties of metals, including titanium and its alloys, was investigated. The basic theories of stress corrosion of titanium alloys are reviewed along with the literature concerned with the effect of absorbed hydrogen on the mechanical properties of metals. Finally, the basic modes of metal fracture and their importance to this study is considered. The experimental work was designed to determine the effects of hydrogen concentration on the critical strain at which plastic instability along pure shear directions occurs. The materials used were titanium alloys Ti-8Al-lMo-lV and Ti-5Al-2.5Sn.

  1. Corrosion behaviour of Ni–Co alloy coatings at Kish Island (marine) atmosphere

    Indian Academy of Sciences (India)

    Kourosh Sharifi; Mohammad Ghorbani

    2014-05-01

    In this study, the corrosion behaviour of Ni-Co alloys with low Co content, electroplated on steel substrate in sulphate bath, was investigated. The morphology of coatings was studied by optical and SEM microscopy. The corrosion products were analyzed using EDX. The results showed that Ni–1% Co coatings had a better corrosion resistance 0.30, 0.92 and 3.75 mpy for atmospheric, salt spray and polarization tests, respectively. These are 0.41, 1.20 and 5.40 mpy for pure nickel coatings that indicate the least corrosion resistance. Surface analysis revealed the presence of oxides, sulphides and chlorides in corrosion products.

  2. Wear resistant steels and casting alloys containing niobium carbide

    Energy Technology Data Exchange (ETDEWEB)

    Theisen, W.; Siebert, S.; Huth, S. [Lehrstuhl Werkstofftechnik, Ruhr-Univ. Bochum (Germany)

    2007-12-15

    Niobium, like titanium and vanadium, forms superhard MC carbides that remain relatively pure in technical alloys on account of their low solubility for other metallic alloying elements. However, because they have a greater hardness than the precipitated chromium carbides commonly used in wear-resistant alloys, they are suitable as alternative hard phases. This contribution deals with new wear-resistant steels and casting alloys containing niobium carbide. These include a secondary hardening hardfacing alloy, a composite casting alloy for wear applications at elevated temperatures, a white cast iron as well as two variants of a corrosion-resistant cold-work tool steel produced by melt metallurgy and by powder metallurgy. A heat-resistant casting alloy is also discussed. Based on equilibrium calculations the microstructures developing during production of the alloys are analysed, and the results are discussed with respect to important properties such as abrasive wear and corrosion resistance. (orig.)

  3. Accelerated corrosion test and corrosion failure distribution model of aircraft structural aluminum alloy

    Institute of Scientific and Technical Information of China (English)

    LIU Wen-lin; MU Zhi-tao; JIN Ping

    2006-01-01

    Based on corrosion damage data of 10 years for a type of aircraft aluminum alloy, the statistical analysis was conducted by Gumbel, Normal and two parameters Weibull distribution function. The results show that aluminum alloy structural member has the corrosion history of pitting corrosion-intergranular corrosion-exfoliation corrosion, and the maximum corrosion depth is in conformity to normal distribution. The accelerated corrosion test was carried out with the complied equivalent airport accelerated environment spectrum. The corrosion damage failure modes of aluminum alloy structural member indicate that the period of validity of the former protective coating is about 2.5 to 3 years, and that of the novel protective coating is about 4.0 to 4.5 years. The corrosion kinetics law of aluminum spar flange was established by fitting corrosion damage test data. The law indicates two apparent corrosion stages of high strength aluminum alloy section material: pitting corrosion and intergranular corrosion/exfoliation corrosion.The test results agree with the statistical fit result of corrosion data collected from corrosion member in service. The fractional error is 5.8% at the same calendar year. The accelerated corrosion test validates the corrosion kinetics law of aircraft aluminum alloy in service.

  4. Corrosion behavior on aluminum alloy LY12 in simulated atmospheric corrosion process

    Institute of Scientific and Technical Information of China (English)

    WANG Zhen-yao; MA Teng; HAN Wei; YU Guo-cai

    2007-01-01

    The corrosion behavior of typical high-strength aluminum alloy LY12 was studied by accelerated corrosion tests of cyclic wet-dry-immersion containing media of NaHSO3 and NaCl to simulate the corrosion process in different atmosphere environment, and the corrosion mechanism was also discussed. The main experimental techniques include mass loss, morphological check, analysis of corrosion products and electrochemical measurement. The result shows that the mass loss of LY12, with or without cladding, has linear relationship with test time in the three kinds of chemical media, 0.02 mol/L NaHSO3, 0.006 mol/L NaCl and 0.02 mol/L NaHSO3+0.006 mol/L NaCl, respectively. A layer of cladding on high-strength aluminum alloy can raise evidently the resistance of atmospheric corrosion. Cl- can promote pitting generation on the oxide film of LY12 when HOS3- exists, LY12 can react much intensely with HOS3- derived from anions.

  5. Corrosion mechanism of micro-arc oxidation treated biocompatible AZ31 magnesium alloy in simulated body fluid

    OpenAIRE

    Ying Li; Fang Lu; Honglong Li; Wenjun Zhu; Haobo Pan; Guoxin Tan; Yonghua Lao; Chengyun Ning; Guoxin Ni

    2014-01-01

    The rapid degradation of magnesium (Mg) based alloys has prevented their further use in orthopedic trauma fixation and vascular intervention, and therefore it is essential to investigate the corrosion mechanism for improving the corrosion resistance of these alloys. In this work, the effect of applied voltage on the surface morphology and the corrosion behavior of micro-arc oxidation (MAO) with different voltages were carried out to obtain biocompatible ceramic coatings on AZ31 Mg alloy. The ...

  6. Effects of niobium on thermal stability and corrosion behavior of glassy Cu Zr Al Nb alloys

    Science.gov (United States)

    Tam, M. K.; Pang, S. J.; Shek, C. H.

    2006-04-01

    The corrosion behavior of Cu95-xZrxAl5 (x=40, 42.5 and 45 at.%) in 1 N HCl, 3 mass% NaCl and 1 N H2SO4 solutions was studied. As Zr content increases, the corrosion resistance is slightly enhanced. In order to improve the corrosion resistance of the Cu Zr Al glassy alloy, Nb was selected to substitute Cu. Although the supercooled liquid region ΔTx of the Cu Zr Al glassy alloys decreases with increasing Nb content, the alloys still retain high glass-forming ability and bulk glassy samples with 1.5 mm diameter can be obtained when up to 5 at.% Nb was added. It is found that the addition of Nb results in improvement of the corrosion resistance of the glassy Cu Zr Al alloys.

  7. Effects of chemical composition on the corrosion of dental alloys

    OpenAIRE

    GALO, Rodrigo; RIBEIRO, Ricardo Faria; RODRIGUES, Renata Cristina Silveira; Rocha, Luís Augusto; Mattos,Maria da Glória Chiarello de

    2012-01-01

    The aim of this study was to determine the effect of the oral environment on the corrosion of dental alloys with different compositions, using electrochemical methods. The corrosion rates were obtained from the current-potential curves and electrochemical impedance spectroscopy (EIS). The effect of artificial saliva on the corrosion of dental alloys was dependent on alloy composition. Dissolution of the ions occurred in all tested dental alloys and the results were strongly dependent on the g...

  8. Study of corrosion erosion behaviour of stainless alloys in industrial phosphoric acid medium

    Science.gov (United States)

    Guenbour, Abdellah; Hajji, Mohamed-Adil; Jallouli, El Miloudi; Bachir, Ali Ben

    2006-12-01

    The corrosion and corrosion-abrasion resistance of some stainless steels in industrial phosphoric acid 30% P 2O 5 has been studied using electrochemical techniques. The corrosion rate of materials increases with the increase of temperature. Alloys which contain chromium, molybdenum and nitrogen in sufficient quantities present the best behaviour. In the abrasion-corrosion conditions, the experimental device set up allowed to follow continually samples electrochemical behaviour. Under dynamic conditions and without solid particles, the increase of acid projection speed has no effect on the alloys corrosion behaviour. The adding of abrasive leads to a general increase of corrosion rate and to a decrease of material resistance. Under these conditions, materials attack is controlled by synergistic effect between the abrasion and the impurities. The cast 30% Cr shows good resistance according to his high chromium content.

  9. Ensuring and improving corrosion resistance in high-alloy welds. Final report; Sicherung und Steigerung der Korrosionsbestaendigkeit hochlegierter Schweissverbindungen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2003-12-22

    The welding process of the two high-alloy austenitic steels X5CrNiMo17 12 2 (1.4404) and X1NiCrMoCuN25 20 5 (1.4539) and the subsequent maintenance of the welds were to be optimized. This comprised detailed investigations into the interdependence between welding technologies and surface treatment. Systematic investigations showed that even with optimized processes, welding involves considerable stress to the materials, leading to structural changes, higher intrinsic stress and tarnish layers. Investigations of surface finishing processes showed that the finishing process and tools have significant effect on corrosion. (orig.) [German] Das Forschungsvorhaben hatte zum Ziel, neben der Optimierung des Schweissprozesses der beiden hochlegierten austenitischen Staehle X5CrNiMo17 12 2 (1.4404) und X1NiCrMoCuN25 20 5 (1.4539), eine auf den Schweissprozess abgestimmte ''Nachsorge'' zu optimieren. Das heisst, dass die Zusammenhaenge zwischen der jeweiligen Schweisstechnologie und der Oberflaechennachbehandlung in ihrer Vielschichtigkeit grundlegend untersucht werden sollen. Es konnte anhand von systematischen schweisstechnischen und werkstofftechnischen Untersuchungen gezeigt werden, dass auch nach einer umfassenden Optimierung des Schweissprozesses das Schweissen fuer den Werkstoff eine erhebliche Beeinflussung darstellt. Es kommt zu Gefuegeveraenderungen, zur Erhoehung der Eigenspannungen und zur Ausbildung von Anlaufschichten. Diese durch das Schweissen bedingten Effekte ueben allesamt einen grossen Einfluss auf das Korrosionsverhalten aus. Weder durch die Optimierung der Schweissparameter (z. B. Streckenenergie) noch durch die Wahl der Art des zu verwendenen Schutz- bzw. Wurzelschutzgases kann die Ausbildung der Anlaufschichten und eine daraus resultierende Veraenderung der Korrosionsbestaendigkeit verhindert werden. Das Korrosionsverhalten laesst sich jedoch positiv z.B. durch die Art des Schutzgases bei Einhaltung der optimierten Schweissparameter

  10. Effects of acidity and alkalinity on corrosion behaviour of Al-Zn-Mg based anode alloy

    Science.gov (United States)

    Ma, Jingling; Wen, Jiuba; Li, Quanan; Zhang, Qin

    2013-03-01

    Effects of 1 M HCl, 0.6 M NaCl with different pH values and 4 M NaOH solutions on the corrosion behaviour of Al-5Zn-1Mg-0.02In-0.05Ti-0.5Mn (wt%) alloy have been investigated using measurements of self-corrosion, potentiodynamic polarization, cyclic polarization experiment combined with open circuit potential technique and scanning electron microscopy. The corrosion behaviour of the alloy was found to be dependant on the Cl-, OH- ions and pH value. In acidic or slightly neutral solutions, general and pitting corrosion occurred simultaneously. In contrast, exposure to alkaline solutions results in general corrosion which was traced back to the dissolution of the resistive oxidation film on the surface of the alloy. Experience revealed that the alloy was susceptible to pitting corrosion in all chloride solution. The alloy undergoes two types of localized corrosion process, leading to the formation of hemispherical and crystallographic pits. Polarization resistance measurements which are in good agreement with those of self-corrosion, show that the corrosion kinetic is minimized in slightly neutral solutions (pH = 7).

  11. Corrosion behavior of Mg-Zn-Ca amorphous alloys with Nd addition in simulated body fluids

    Directory of Open Access Journals (Sweden)

    Qin Chunling

    2014-11-01

    Full Text Available The effects of Nd addition on corrosion behavior of Mg66Zn30Ca4 amorphous alloys in simulated body fluids (SBF were studied in this paper. Electrochemical properties of the samples before and after corrosion were determined. Surface morphologies of samples after immersion in SBF at 37 篊 for different times were observed under scanning electron microscope (SEM. Results show that the corrosion resistance of Mg-based alloys in SBF is improved with the addition of Nd element. The electrochemical properties indicate that microalloying Nd element to the alloys leads to an ennoblement in the open circuit potentials of the alloys and a decrease in the anodic current density in SBF, especially for the Mg66-xZn30Ca4Ndx alloys with Nd content of 1.0at.%-1.5at.%. It was observed that the surface morphologies of the alloys immersed in SBF change with the Nd addition. A flake-like structure parallel to the alloy substrate formed on the surface of 1.0at.% Nd-containing alloy immersed in SBF for 7 days improves the corrosion resistance of the amorphous alloys by blocking the corrosion liquid from attacking the alloys.

  12. Environmental and Geometrical Conditions to Sustain Crevice Corrosion in Alloy 22

    Energy Technology Data Exchange (ETDEWEB)

    Carranza, R M; Rodr?guez, M A; Rebak, R B

    2006-11-10

    Alloy 22 (N06022) is highly resistant to localized corrosion. Under aggressive environmental conditions Alloy 22 may be susceptible to crevice corrosion in hot chloride (Cl{sup -}) solutions. The objective of the present work was to explore the environmental and geometrical conditions for crevice corrosion to occur. Electrochemical tests were performed using PCA and prismatic mill annealed Alloy 22 specimens in chloride solutions. Crevice corrosion current density was found to be a function of applied potential. i{sub CREV} values ranged from 40 {micro}A/cm{sup 2} to 20 mA/cm{sup 2}. Such low values of current density explained the absence of pitting corrosion in Alloy 22 at any potential. Decreasing of the effective diffusion distance in a propagating crevice is thought to cause crevice corrosion stifling or repassivation after long anodic polarization. Crevice corrosion breakdown potential is expected to decrease with potential scan rate, approaching repassivation potential for low scan rates. The lowest corrosion potential of Alloy 22 in hydrochloric acid solutions at which active corrosion exists was proposed as the lowest possible repassivation potential for crevice corrosion.

  13. Corrosion behaviors of zinc and Zn-Ni alloy compositionally modulated multilayer coatings

    Institute of Scientific and Technical Information of China (English)

    Jingyin Fei; Guozheng Liang; Wenli Xin; Weikang Wang; Jianghong Liu

    2005-01-01

    Zinc and Zn-Ni alloy compositionally modulated multilayer (CMM) coatings were electrodeposited from dual baths. The coated samples were evaluated in terms of surface appearance, surface and cross-sectional morphologies, as well as corrosion resistance. The results obtained from the salt spray test show that the zinc and Zn-Ni alloy CMM coatings are more corrosion-resistant than the monolithic coatings of zinc or Zn-Ni alloy alone with a similar thickness. The corrosion potential measurement and anodic polarisation tests were undertaken to examine the probable corrosion mechanisms of zinc and Zn-Ni alloy CMM coatings. Analysis on the micrographic features of zinc and Zn-Ni alloy CMM coatings after the corrosion test explains the probable reasons why the Zn-Ni/Zn CMM coatings have a better protective performance. Surface morphologies and compositional analysis of the remaining coating material of Zn-Ni alloy deposit after the corrosion test confirms the dezincification mechanism of the Zn-Ni alloy deposit during the corrosion process.

  14. On the corrosion behavior and biocompatibility of palladium-based dental alloys

    Science.gov (United States)

    Sun, Desheng

    Palladium-based alloys have been used as dental restorative materials for about two decades with good clinical history. But there have been clinical case reports showing possible allergy effects from these alloys. The aim of this study was to characterize the corrosion behavior and mechanisms of several palladium-based dental alloys by potentiodynamic polarization methods, electrochemical impedance spectroscopy (EIS), and scanning Kelvin probe force microscopy/atomic force microscopy (SKPFM/AFM), and to evaluate their biocompatibility by a cell culture technique and an animal model. Using SKPFM/AFM and scanning electron microscopy, the Ru-enriched phase from the use of ruthenium as a grain-refining element was identified as being slightly more noble than the palladium solid solution matrix in a high-palladium alloy. Other secondary precipitates that exist in the microstructures of these high-palladium alloys have minimal differences in Volta potential compared to the matrix. For high-palladium alloys, corrosion is generally uniform due to the predominant palladium content in the different phases. Potentiodynamic polarization and EIS have shown that representative palladium-silver alloys have low corrosion tendency and high corrosion resistance, which are equivalent to a well-known high-noble gold-palladium alloy in simulated body fluid and oral environments. The palladium-silver alloys tested are resistant to chloride ion corrosion. Passivation and dealloying have been identified for all of the tested palladium-silver alloys. The great similarity in corrosion behavior among the palladium-silver alloys is attributed to their similar chemical compositions. The variation in microstructures of palladium-silver alloys tested does not cause significant difference in corrosion behavior. The corrosion resistance of these palladium-silver alloys at elevated potentials relevant to oral environment is still satisfactory. The release of elements from representative dental

  15. Study of localized corrosion in aluminum alloys by the scanning reference electrode technique

    Science.gov (United States)

    Danford, M. D.

    1995-01-01

    Localized corrosion in 2219-T87 aluminum (Al) alloy, 2195 aluminum-lithium (Al-Li) alloy, and welded 2195 Al-Li alloy (4043 filler) have been investigated using the relatively new scanning reference electrode technique (SRET). Anodic sites are more frequent and of greater strength in the 2195 Al-Li alloy than in the 2219-T87 Al alloy, indicating a greater tendency toward pitting for the latter. However, the overall corrosion rates are about the same for these two alloys, as determined using the polarization resistance technique. In the welded 2195 Al-Li alloy, the weld bean is entirely cathodic, with rather strongly anodic heat affected zones (HAZ) bordering both sides, indicating a high probability of corrosion in the HAZ parallel to the weld bead.

  16. 牙用镍铬合金表面不同涂层电化学腐蚀研究%A research on the corrosion resistance of Ni-Cr alloy with different coatings

    Institute of Scientific and Technical Information of China (English)

    张丽仙; 赵铱民; 邵龙泉; 柳玉晓

    2009-01-01

    目的:通过电化学腐蚀法测试镍铬合金表面不同涂层在中性及酸性环境中的抗腐蚀性能.方法:分别以中性和酸性人工唾液为电解液,测量不同涂层的镍铬合金试件电极的自然腐蚀电位Ecorr、极化电阻Rp.结果:在中性和酸性人工唾液中,无论镀膜与否的镍铬合金的自腐蚀电位(Ecorr)均为正值,不易发生电化学腐蚀和电偶腐蚀.结论:氮化钛膜、电镀金膜、金泥涂层及金瓷涂层的镍铬合金具有较强抗腐蚀性和美观性,可提高基体金属的耐腐蚀性能.%Objective: To evaluate the corrosion resistance of Ni-Cr alloy with different coatings in neutral and acid saliva by electrochemistry method. Methods: Measured the self-corrosion potential (Ecorr) and polarization resistance(Rp) curves of Ni-Cr alloy models with different coatings in neutral and acid artificial salivas. Results: The Ecorr of the Ni-Cr alloys all showed positive values, the electrochemistry corrosion and galvanic corrosion were not detected. Conclusion: Ni-Cr alloy with titanium nitride coating, gold electroplating coating, gold-paste layer and gold-porcelain blended layer have both anti-corrosion and esthetical function without changing its own property.

  17. Effect of Ca addition on the corrosion behavior of Mg-Al-Mn alloy

    Science.gov (United States)

    Yang, Jiang; Peng, Jian; Nyberg, Eric A.; Pan, Fu-sheng

    2016-04-01

    The microstructures and corrosion resistance of magnesium-5 wt% aluminum-0.3 wt% manganese alloys (Mg-Al-Mn) with different Ca additions (0.2-4 wt%) were investigated. Results showed that with increasing Ca addition, the grain of the alloys became more refined, whereas the corrosion resistant ability of the alloys initially increased and then decreased. The alloy with 2 wt% Ca addition exhibited the best corrosion resistance, attributed to the effect of the oxide film and (Mg,Al)2Ca phases which were discontinuously distributed on the grain boundaries. These phases acted as micro-victims, they preferentially corroded to protect the α-Mg matrix. The oxide film formed on the alloy surface can hinder the solution further to protect the α-Mg matrix.

  18. Pitting corrosion of A357 aluminium alloy obtained by semisolid processing

    Energy Technology Data Exchange (ETDEWEB)

    Bastidas, J.M.; Polo, J.L.; Torres, C.L. [National Centre for Metallurgical Research (CSIC), Madrid (Spain); Forn, A.; Baile, M.T. [Polytechnic Univ. of Catalonia, Vilanova i la Geltru (Spain)

    2001-09-01

    This paper studies the pitting corrosion of a structural component of A357 aluminium alloy obtained by a semisolid metal forming process. The mechanical properties of the A357 alloy were improved by applying standard heat treatments T5 and T6. Impedance measurements were conducted at the rest potential and polarisation curves were plotted using a 3% NaCl test solution. After polarisation experiments the specimens were analysed by scanning electron microscopy. The corrosion process is favoured through the eutectic regions. The results show that T6 heat treatment improved the corrosion resistance of the A357 aluminium alloy. (orig.)

  19. Corrosion resistant coating

    Science.gov (United States)

    Wrobleski, Debra A.; Benicewicz, Brian C.; Thompson, Karen G.; Bryan, Coleman J.

    1997-01-01

    A method of protecting a metal substrate from corrosion including coating a metal substrate of, e.g., steel, iron or aluminum, with a conductive polymer layer of, e.g., polyaniline, coating upon said metal substrate, and coating the conductive polymer-coated metal substrate with a layer of a topcoat upon the conductive polymer coating layer, is provided, together with the resultant coated article from said method.

  20. Surface corrosion enhancement of passive films on NiTi shape memory alloy in different solutions.

    Science.gov (United States)

    Jinlong, Lv; Tongxiang, Liang; Chen, Wang; Limin, Dong

    2016-06-01

    The corrosion behaviors of NiTi shape memory alloy in NaCl solution, H2SO4 solution and borate buffer solution were investigated. It was found that TiO2 in passive film improved the corrosion resistance of NiTi shape memory. However, low corrosion resistance of passive film was observed in low pH value acidic solution due to TiO2 dissolution. Moreover, the corrosion resistance of NiTi shape memory alloy decreased with the increasing of passivated potential in the three solutions. The donor density in passive film increased with the increasing of passivated potential. Different solutions affect the semiconductor characteristics of the passive film. The reducing in the corrosion resistance was attributed to the more donor concentrations in passive film and thinner thickness of the passive film.

  1. Development of Semi-Stochastic Algorithm for Optimizing Alloy Composition of High-Temperature Austenitic Stainless Steels (H-Series) for Desired Mechanical and Corrosion Properties.

    Energy Technology Data Exchange (ETDEWEB)

    Dulikravich, George S.; Sikka, Vinod K.; Muralidharan, G.

    2006-06-01

    The goal of this project was to adapt and use an advanced semi-stochastic algorithm for constrained multiobjective optimization and combine it with experimental testing and verification to determine optimum concentrations of alloying elements in heat-resistant and corrosion-resistant H-series stainless steel alloys that will simultaneously maximize a number of alloy's mechanical and corrosion properties.

  2. Comparison of corrosion behavior of ZL104 alloy at as-cast and heat treatment states

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The corrosion behavior of ZL 104 alloy at different states (as-cast and heat treatment) in salt spray corrosion (SSC) was studied. The results show that the sample treated after refinement and modification has the least corrosive resistance compared with the sample bearing as-cast structure at the beginning of the corrosion. As the corrosion process continued, however, the trend reversed itself. After 44 h continuous corrosion, the corrosive rates of all samples tend to be stable. After experiments, the sample bearing as-cast structure had the most corrosive products on the surface whereas the sample being refined and modified had the least products. The Fourier transformation infrared spectroscopy (FTIR)analyses of the corrosion products show that these products are composed of hydroxyl-containing substances.

  3. Electrical Resistance Alloys and Low-Expansion Alloys

    DEFF Research Database (Denmark)

    Kjer, Torben

    1996-01-01

    The article gives an overview of electrical resistance alloys and alloys with low thermal expansion. The electrical resistance alloys comprise resistance alloys, heating alloys and thermostat alloys. The low expansion alloys comprise alloys with very low expansion coefficients, alloys with very low...

  4. Corrosion resistant metallic bipolar plate

    Science.gov (United States)

    Brady, Michael P.; Schneibel, Joachim H.; Pint, Bruce A.; Maziasz, Philip J.

    2007-05-01

    A corrosion resistant, electrically conductive component such as a bipolar plate for a PEM fuel cell includes 20 55% Cr, balance base metal such as Ni, Fe, or Co, the component having thereon a substantially external, continuous layer of chromium nitride.

  5. CORROSION RESISTANT JACKETED METAL BODY

    Science.gov (United States)

    Brugmann, E.W.

    1958-08-26

    Reactor faul elements of the elongated cylindrical type which are jacketed in a corrosion resistant material are described. Each feel element is comprised of a plurality of jacketed cylinders of fissionable material in end to end abutting relationship, the jackets being welded together at their adjoining ends to retain the individual segments together and seat the interior of the jackets.

  6. Chemical conversion coating for protecting magnesium alloys from corrosion

    Science.gov (United States)

    Bhargava, Gaurang; Allen, Fred M.; Skandan, Ganesh; Hornish, Peter; Jain, Mohit

    2016-01-05

    A chromate-free, self-healing conversion coating solution for magnesium alloy substrates, composed of 10-20 wt. % Mg(NO.sub.3).sub.2.6H.sub.2O, 1-5 wt. % Al(NO.sub.3).sub.3.9H.sub.2O, and less than 1 wt. % of [V.sub.10O.sub.28].sup.6- or VO.sub.3.sup.- dissolved in water. The corrosion resistance offered by the resulting coating is in several hundreds of hours in salt-spray testing. This prolonged corrosion protection is attributed to the creation of a unique structure and morphology of the conversion coating that serves as a barrier coating with self-healing properties. Hydroxoaluminates form the backbone of the barrier protection offered while the magnesium hydroxide domains facilitate the "slow release" of vanadium compounds as self-healing moieties to defect sites, thus providing active corrosion protection.

  7. Review of studies on corrosion of magnesium alloys

    Institute of Scientific and Technical Information of China (English)

    ZENG Rong-chang; ZHANG jin; HUANG Wei-jiu; W. DIETZEL; K. U. KAINER; C. BLAWERT; KE Wei

    2006-01-01

    This review provided some recent progress of the research on corrosion mechanisms of magnesium and its alloys and a basis for follow-on research. Galvanic corrosion,pitting corrosion,intergranular corrosion (IGC),filiform corrosion,crevice corrosion,stress corrosion cracking (SCC),and corrosion fatigue (CF) were discussed. The influence of metallurgical factors such as alloying elements,microstructure and secondary phases,processing factors such as heat treatment and weld,and environmental factors including temperature,relative humidity,solution pH values and concentration on corrosion were discussed. In particular,a mechanism of pitting corrosion caused by AlMn particles was proposed. The corrosion properties of AZ91D weld material were investigated.

  8. Coatings for Oxidation and Hot Corrosion Protection of Disk Alloys

    Science.gov (United States)

    Nesbitt, Jim; Gabb, Tim; Draper, Sue; Miller, Bob; Locci, Ivan; Sudbrack, Chantal

    2017-01-01

    Increasing temperatures in aero gas turbines is resulting in oxidation and hot corrosion attack of turbine disks. Since disks are sensitive to low cycle fatigue (LCF), any environmental attack, and especially hot corrosion pitting, can potentially seriously degrade the life of the disk. Application of metallic coatings are one means of protecting disk alloys from this environmental attack. However, simply the presence of a metallic coating, even without environmental exposure, can degrade the LCF life of a disk alloy. Therefore, coatings must be designed which are not only resistant to oxidation and corrosion attack, but must not significantly degrade the LCF life of the alloy. Three different Ni-Cr coating compositions (29, 35.5, 45wt. Cr) were applied at two thicknesses by Plasma Enhanced Magnetron Sputtering (PEMS) to two similar Ni-based disk alloys. One coating also received a thin ZrO2 overcoat. The coated samples were also given a short oxidation exposure in a low PO2 environment to encourage chromia scale formation. Without further environmental exposure, the LCF life of the coated samples, evaluated at 760C, was less than that of uncoated samples. Hence, application of the coating alone degraded the LCF life of the disk alloy. Since shot peening is commonly employed to improve LCF life, the effect of shot peening the coated and uncoated surface was also evaluated. For all cases, shot peening improved the LCF life of the coated samples. Coated and uncoated samples were shot peened and given environmental exposures consisting of 500 hrs of oxidation followed by 50 hrs of hot corrosion, both at 760C). The high-Cr coating showed the best LCF life after the environmental exposures. Results of the LCF testing and post-test characterization of the various coatings will be presented and future research directions discussed.

  9. Study of surface interactions of ionic liquids with aluminium alloys in corrosion and erosion corrosion processes

    Science.gov (United States)

    Bermúdez, María-Dolores; Jiménez, Ana-Eva; Martínez-Nicolás, Ginés

    2007-06-01

    Surface interactions of alkylimidazolium ionic liquids (ILs) with aluminium alloy Al 2011 have been studied by immersion tests in seven neat ILs [1- n-alkyl-3-methylimidazolium X - (X = BF 4; n = 2 (IL1), 6 (IL2), 8 (IL3). X = CF 3SO 3; n = 2 (IL4). X = (4-CH 3C 6H 4SO 3); n = 2 (IL5). X = PF 6; n = 6 (IL6)] and 1-butyl-3-methylpyridinium bis(trifluoromethylsulfonyl)imide (IL7)]. Immersion tests for Al 2011 have also been carried out in 1 wt.% and 5 wt.% solutions of 1-ethyl,3-methylimidazolium tetrafluoroborate (IL1) in water. No corrosion of Al 2011 by neat ILs is observed. The highest corrosion rate for Al 2011 in water is observed in the presence of a 5 wt.% IL1 due to hydrolysis of the anion with hydrogen evolution and formation of aluminium fluoride. Erosion-corrosion processes have been studied for three aluminium alloys (Al 2011, Al 6061 and Al 7075) in a 90 wt.% IL1 solution in water in the presence of α-alumina particles. The erosion-corrosion rates are around 0.2 mm/year or lower, and increase with increasing copper content to give a corrosion resistance order of Al 6061 > Al 7075 > Al 2011. Results are discussed on the basis of scanning electron microscopy (SEM) observations, energy dispersive spectroscopy (EDS) analysis, X-ray diffraction (XRD) patterns and X-ray photoelectron spectroscopy (XPS) determinations.

  10. Effect of heat treatment on the inhibition of the acidic corrosion aluminium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Khamis, E. (Alexandria Univ. (Egypt). Dept. of Chemistry); El-Gamal, M. (Alexandria Univ. (Egypt). Dept. of Material Science); El-Toukhy, A. (Alexandria Univ. (Egypt). Dept. of Material Science); Atea, M. (Alexandria Univ. (Egypt). Dept. of Material Science)

    1994-12-01

    The effect of heat treatment on the inhibition of acid corrosion of duralumin has been studied using gasometry, mass loss measurements and potentiodynamic technique. All the data reveal that the duralumin generally developed good corrosion resistance after heat treatment and the corrosion rate ranked as follows: Non treated > Naturally aged > quenched. This improvement in the corrosion resistance was attributed to the structural homogeneity of the heat-treated alloys. The presence of some selected aryl and alkyl triazoline derivatives at the threshold concentration of 5 x 10[sup -3] M indicate that these compounds retard the corrosion rate of duralumin and the extent of inhibition depends on the molecular structure of the inhibitors. Polarization curves show that the triazoline compounds act as mixed-type inhibitors affecting both the cathodic and anodic processes. Moreover, there is no noticeable difference in the degree by which the triazoline derivatives inhibit the corrosion of pure aluminium and heat treated duralumin alloy. (orig.)

  11. Creep Resistant Zinc Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Frank E. Goodwin

    2002-12-31

    This report covers the development of Hot Chamber Die Castable Zinc Alloys with High Creep Strengths. This project commenced in 2000, with the primary objective of developing a hot chamber zinc die-casting alloy, capable of satisfactory service at 140 C. The core objectives of the development program were to: (1) fill in missing alloy data areas and develop a more complete empirical model of the influence of alloy composition on creep strength and other selected properties, and (2) based on the results from this model, examine promising alloy composition areas, for further development and for meeting the property combination targets, with the view to designing an optimized alloy composition. The target properties identified by ILZRO for an improved creep resistant zinc die-casting alloy were identified as follows: (1) temperature capability of 1470 C; (2) creep stress of 31 MPa (4500 psi); (3) exposure time of 1000 hours; and (4) maximum creep elongation under these conditions of 1%. The project was broadly divided into three tasks: (1) Task 1--General and Modeling, covering Experimental design of a first batch of alloys, alloy preparation and characterization. (2) Task 2--Refinement and Optimization, covering Experimental design of a second batch of alloys. (3) Task 3--Creep Testing and Technology transfer, covering the finalization of testing and the transfer of technology to the Zinc industry should have at least one improved alloy result from this work.

  12. Creep Resistant Zinc Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Frank E. Goodwin

    2002-12-31

    This report covers the development of Hot Chamber Die Castable Zinc Alloys with High Creep Strengths. This project commenced in 2000, with the primary objective of developing a hot chamber zinc die-casting alloy, capable of satisfactory service at 140 C. The core objectives of the development program were to: (1) fill in missing alloy data areas and develop a more complete empirical model of the influence of alloy composition on creep strength and other selected properties, and (2) based on the results from this model, examine promising alloy composition areas, for further development and for meeting the property combination targets, with the view to designing an optimized alloy composition. The target properties identified by ILZRO for an improved creep resistant zinc die-casting alloy were identified as follows: (1) temperature capability of 1470 C; (2) creep stress of 31 MPa (4500 psi); (3) exposure time of 1000 hours; and (4) maximum creep elongation under these conditions of 1%. The project was broadly divided into three tasks: (1) Task 1--General and Modeling, covering Experimental design of a first batch of alloys, alloy preparation and characterization. (2) Task 2--Refinement and Optimization, covering Experimental design of a second batch of alloys. (3) Task 3--Creep Testing and Technology transfer, covering the finalization of testing and the transfer of technology to the Zinc industry should have at least one improved alloy result from this work.

  13. Electrochemical corrosion behavior of Ni-containing hypoeutectic Al-Si alloy

    Directory of Open Access Journals (Sweden)

    Abul Hossain

    2015-12-01

    Full Text Available Electrochemical corrosion characteristics of the thermally treated 2 wt % Ni-containing Al-6Si-0.5Mg alloy were studied in NaCl solutions. The corrosion behavior of thermally treated (T6 Al-6Si-0.5Mg (-2Ni alloys in 0.1 M NaCl solution was investigated by electrochemical potentiodynamic polarization technique consisting of linear polarization method using the fit of Tafel plot and electrochemical impedance spectroscopy (EIS techniques. Generally, linear polarization experiments revealed a decrease of the corrosion rate at thermal treated Al-6Si-0.5Mg-2Ni alloy. The EIS test results showed that there is no significant change in charge transfer resistance (Rct after addition of Ni to Al-6Si-0.5Mg alloy. The magnitude of the positive shift in the open circuit potential (OCP, corrosion potential (Ecorr and pitting corrosion potential (Epit increased with the addition of Ni to Al-6Si-0.5Mg alloy. The forms of corrosion in the studied Al-6Si-0.5Mg alloy (except Al-6Si-0.5Mg-2Ni alloy are pitting corrosion as obtained from the scanning electron microscopy (SEM study.

  14. Corrosion of Aluminum Alloys by IRFNA

    Science.gov (United States)

    1990-02-24

    and electropolishing and anodising, have been studied. aNeither had a significant long term effect on the corrosion rate of 2014 alumninium alloy in... steel spatula. (iv) The cell was assembled and raw eghed, the charge of galled Acid being determined by difference. Two additional bottom-working...The anodiuing solution was 1swt% sulphuric acid And the conditions were 25oC, 1 Mwm, 12V. The anodic oxide film waS scaled in delonised water (30

  15. Modeling corrosion behavior of gas tungsten arc welded titanium alloy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The pitting corrosion characteristics of pulse TIG welded Ti-6Al-4V titanium alloy in marine environment were explained.Besides the rapid advance of titanium metallurgy, this is also due to the successful solution of problems associated with the development of titanium alloy welding. The preferred welding process of titanium alloy is frequently gas tungsten arc(GTA) welding due to its comparatively easier applicability and better economy. In the case of single pass GTA welding of thinner section of this alloy, the pulsed current has been found beneficial due to its advantages over the conventional continuous current process. The benefit of the process is utilized to obtain better quality titanium weldments. Four factors, five levels, central composite, rotatable design matrix are used to optimize the required number of experiments. The mathematical models have been developed by response surface method(RSM). The results reveal that the titanium alloy can form a protective scale in marine environment and is resistant to pitting corrosion. Experimental results are provided to illustrate the proposed approach.

  16. Preparation and corrosion resistance studies of nanometric sol-gel-based CeO{sub 2} film with a chromium-free pretreatment on AZ91D magnesium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Shiyan [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Li Qing, E-mail: liqingswu@yeah.ne [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Chen Bo [School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715 (China); Yang Xiaokui [School of Materials Science and Engineering, Southwest University, Chongqing 400715 (China)

    2010-01-01

    Magnesium alloy, although valuable, is reactive and requires protection before it can be applied in many fields. In this study, a novel protective environmental-friendly gradient coating was performed on AZ91D magnesium alloy by non-chromate surface treatments, which consisted of phytic acid chemical conversion coating and the sol-gel-based CeO{sub 2} thin film. The surface morphologies, microstructure and composition of the coatings were investigated by scanning electron microscopy (SEM), energy disperse spectroscopy (EDS) and X-ray diffraction (XRD), respectively. The corrosion resistance of the coatings was evaluated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) in 3.5 wt.% NaCl solution. The effects of the concentration, layers, temperature of heat treatment of CeO{sub 2} sol on the anti-corrosion properties of the gradient coating for magnesium were also investigated. The results showed that the gradient coating was mainly composed of crystalline CeO{sub 2}. According to the results of electrochemical tests, the corrosion resistance of AZ91D magnesium alloy was found to be greatly improved by means of this new environmental-friendly surface treatment.

  17. Investigation of Corrosion Behavior of Wrought Stellite Alloys

    Science.gov (United States)

    Zhang, Xiaozhou

    The corrosion behavior of two wrought Stellite alloys, Stellite 6B and Stellite 6K, is studied under polarization test and immersion test. Two types of corrosive media, 3.5 wt% sodium chloride (NaCl) aqueous solution and Green Death solution, are used in the polarization test. Both potentiodynamic polarization and cyclic polarization testes are performed to investigate general and localized corrosion resistance of these alloys. Immersion tests of the two alloys are conducted in Green Death solution to determine Critical Pitting Temperature (CPT), mass loss, thickness change and the Extreme Value (minimum thickness) of the Extreme Value Analysis (EVA) model which derived from the Gumbel Distribution. The minimum thickness for Stellite 6B and Stellite 6K that is required for an assumed service time is predicted. Maximum pit depths, which are the input of the EVA model, are measured using a surface texture and contour measuring instrument. A Scanning Electron Microscope (SEM) with Energy Dispersive X-ray (EDX) spectrum is utilized to analyze the chemical composition of the corrosion products (pits). The CPTs of Stellite 6B and Stellite 6K in Green Death solution are determined to be all 60°C. The experimental results demonstrate that Stellite 6B and Stellite 6K have good general and localized corrosion resistance by forming the protective Cr-oxide film. However, the presence of carbides generates potential in the electrochemical reaction, causing corrosion of the alloys in the solution. The larger the carbide volume fraction is, the more the pits are forming in the alloy. Carbide size affects maximum pit depths; the larger the carbide size is, the bigger and deeper the pits are. The EDX analysis results of pits show large amount of oxygen in the carbide phase and small amount of oxygen in the solid solution phase. The Cr-rich carbides react with oxygen forming Cr-rich carbonates which are easily brittle, loose and broken, while Cr in the solid solution reacts with

  18. Corrosion Resistance of the Superhydrophobic Mg(OH)2/Mg-Al Layered Double Hydroxide Coatings on Magnesium Alloys

    National Research Council Canada - National Science Library

    Zhang, Fen; Zhang, Changlei; Zeng, Rongchang; Song, Liang; Guo, Lian; Huang, Xiaowen

    2016-01-01

      Coatings of the Mg(OH)2/Mg-Al layered double hydroxide (LDH) composite were formed by a combined co-precipitation method and hydrothermal process on the AZ31 alloy substrate in alkaline condition...

  19. Corrosion resistance of Ti-6Al-4V and ASTM F75 alloys processed by electron beam melting

    National Research Council Canada - National Science Library

    E. Almanza; M.J. Pérez; N.A. Rodríguez; L.E. Murr

    2017-01-01

    The electron beam melting (EBM) is a useful technique for fabricating alloys that are difficult to machine and require expensive tools as well as the presence of inert atmosphere for further treatments...

  20. Microstructure and corrosion behavior of binary titanium alloys with beta-stabilizing elements.

    Science.gov (United States)

    Takada, Y; Nakajima, H; Okuno, O; Okabe, T

    2001-03-01

    Binary titanium alloys with the beta-stabilizing elements of Co, Cr, Cu, Fe, Mn and Pd (up to 30%) and Ag (up to 45%) were examined through metallographic observation and X-ray diffractometry to determine whether beta phases that are advantageous for dental use could be retained. Corrosion behavior was also investigated electrochemically and discussed thermodynamically. Some cast alloys with Co, Cr, Fe, Mn, and Pd retained the beta phase, whereas those with Ag and Cu had no beta phase. In some alloys, an intermetallic compound formed, based on information from the phase diagram. The corrosion resistance deteriorated in the TiAg alloys because Ti2Ag and/or TiAg intermetallic compounds preferentially dissolved in 0.9% NaCl solution. On the other hand, the remaining titanium alloys became easily passive and revealed good corrosion resistance similar to pure titanium since their matrices seemed to thermodynamically form titanium oxides as did pure titanium.

  1. DIFFUSION COATINGS FOR CORROSION RESISTANT COMPONENTS IN COAL GASIFICATION SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    Gopala N. Krishnan; Ripudaman Malhotra; Angel Sanjurjo

    2004-05-01

    Heat-exchangers, filters, turbines, and other components in integrated coal gasification combined cycle system must withstand demanding conditions of high temperatures and pressure differentials. Under the highly sulfiding conditions of the high temperature coal gas, the performance of components degrade significantly with time unless expensive high alloy materials are used. Deposition of a suitable coating on a low cost alloy may improve is resistance to such sulfidation attack and decrease capital and operating costs. A review of the literature indicates that the corrosion reaction is the competition between oxidation and sulfidation reactions. The Fe- and Ni-based high-temperature alloys are susceptible to sulfidation attack unless they are fortified with high levels of Cr, Al, and Si. To impart corrosion resistance, these elements need not be in the bulk of the alloy and need only be present at the surface layers.

  2. Corrosion Behavior of Commercial Aluminum Alloy Processed by Equal Channel Angular Pressing

    Directory of Open Access Journals (Sweden)

    Atef Korchef

    2013-01-01

    Full Text Available A commercial aluminum alloy was subjected to severe plastic deformation through equal channel angular pressing (ECAP. The alloy contains a low volume fraction of α-AlFeSi located essentially at the grain boundaries. The corrosion behavior of the ECAP’ed alloy was investigated in NaCl solution using potentiodynamic polarization and immersion tests. The effects of scan rate and NaCl concentration on the alloy susceptibility to corrosion were also studied. The results obtained were compared with those of the nonpressed alloy. ECAP leads to an intensive grain refinement accompanied by an increased dislocation density. All electrochemical tests confirm that corrosion resistance of the alloy remarkably diminished with increasing the ECAP number of passes. This is presumably due to the breakdown of the α-AlFeSi after ECAP leading to higher number of galvanic cells and enhanced dissolution of the aluminum matrix.

  3. Simulating the corrosion of zirconium alloys in the water coolant of VVER reactors

    Science.gov (United States)

    Kritskii, V. G.; Berezina, I. G.; Motkova, E. A.

    2013-07-01

    A model for predicting the corrosion of cladding zirconium alloys depending on their composition and operating conditions is proposed. Laws of thermodynamics and chemical kinetics of the reactions through which the multicomponent zirconium alloy is oxidized in the reactor coolant constitute the physicochemical heart of the model. The developed version of the model is verified against the results obtained from tests of fuel rod claddings made of commercial-grade and experimental zirconium alloys carried out by different researchers under autoclave and reactor conditions. It is shown that the proposed model adequately describes the corrosion of alloys in coolants used at nuclear power stations. It is determined that, owing to boiling of coolant and its acidification in a VVER-1200 reactor, Zr-1% Nb alloys with additions of iron and oxygen must be more resistant to corrosion than the commercial-grade alloy E110.

  4. Corrosion behavior of an Al-6Mg-Sc-Zr alloy

    Institute of Scientific and Technical Information of China (English)

    XU Guangxing; TAO Binwu; LIU Jianhua; LI Songmei

    2005-01-01

    The corrosion behavior of an Al-6Mg-Sc-Zr alloy was studied and compared with that of an Al-6Mg-Zr alloy.The addition of scandium into the Al-6Mg-Zr alloy reduced the susceptibility to exfoliation corrosion. By using the constant load tensile method in a 3.5 wt.% NaCl solution, the resistance to SCC of the Al-6Mg-Sc-Zr alloy was higher than that of the Al-6Mg-Zr alloy. When the specimens were not applied with an anodic current, the Al-6Mg-Sc-Zr alloy was resistance to SCC and no brittle cracking was found on the fracture surface. When an anodic current was applied, the Al-6Mg-Sc-Zr alloy specimens failed as a result of accelerated corrosion rather than SCC. It was believed that the addition of scandium resulted in (Al3Sc, Zr) particles that greatly refmed grains and promoted the formation of homogeneous discontinuous distribution of β-phase in the alloy base, which much contributed to good corrosion resistance of the Al-6Mg-Sc-Zr alloy.

  5. Generation reason and corrosion characteristic of cavity of tinplate alloy layer

    Institute of Scientific and Technical Information of China (English)

    黄久贵; 李宁; 周德瑞

    2004-01-01

    The surface morphology of alloy layer of tinplate was studied by means of scanning electron microscopy.By using the layer on layer debonding technology of glow discharge spectrum, the contents of C and O at the boundary of alloy layer and black plate were analyzed. And the corrosion characteristic of cavity of tinplate alloy layer was studied on-line and in-situ by means of electrochemical atomic force microscope. The corrosion depth of cavity of alloy layer in-situ after different corrosion time was measured. The results show that the cavity of alloy layer is a critical factor causing rapid decline of corrosion resistance of tinplate, and the formation of cavity of alloy layer is due to incorrect pretreatment of black plate before electrotinning. The cavity of alloy layer is the internal factor causing pitting corrosion of tinplate when the tinplate is applied to food packaging material. And the dynamic equation of pitting corrosion generated in the cavity of alloy layer conforms to logarithm law.

  6. Influence of Welding and Subsequent Vacuum Annealing on Corrosion Resistance of Zr-1Nb Alloy%焊接及随后热处理对Zr-1Nb合金腐蚀抗力的影响

    Institute of Scientific and Technical Information of China (English)

    薛祥义; 白新德; 刘建章; 周青山

    2005-01-01

    In order to prompt self-making of Zr-1Nb fuel cladding and end plug bar for VVER-1000 reactors located at TIAN WAN, China, imported from Russia, the influence of welding and subsequent vacuum annealing on corrosion resistance of Zr-1Nb alloy in 360℃, 18.6 MPa water and 500℃, 10.3 MPa steam was investigated through testing in autoclave in this paper.TIG method was employed to weld the Zr-1Nb alloy sheet of 1 mm in thickness, then, vacuum annealing was conducted at 470℃, 560℃, 700℃ respectively. The samples prepared through above steps were charged into the autoclave with 360℃,18.6 MPa water and 500℃, 10.3 MPa steam for corrosion test up to 350 days and 244 hours. The weights of the samples were measured periodically. The test results show that welding weakens seriously the corrosion resistance of Zr-1Nb alloy in both high temperature and high pressure water and steam due to the appearance of coarse Martensite; The influence of the subsequent vacuum annealing on the corrosion resistance depends on annealing temperature and corrosion test temperature.However, annealing, even at the optimized temperature, doesn't improve considerably corrosion resistance of the welded alloy.%为了推进从俄罗斯引进的田湾VVER-1000型核电站用Zr-1Nb合金燃料包壳和端塞棒材的国产化进程,研究了焊接及随后的真空热处理对Zr-1Nb合金抗360℃,18.6 MPa水和500℃,10.3 MPa蒸汽腐蚀性能的影响.实验结果表明焊接严重恶化Zr-1Nb合金在2种介质中的腐蚀抗力,主要是因为焊区中出现了粗大的马氏体组织;随后的真空退火对腐蚀抗力的影响取决于退火温度和腐蚀实验温度.但即使在最佳温度退火也不能使焊接态的腐蚀抗力恢复到非焊接态的水平.

  7. Microstmcture and Corrosion Resistance of Cold - Sprayed Zinc - Nickel Alloy Coatings%冷喷涂锌镍合金层的组织结构及耐蚀性

    Institute of Scientific and Technical Information of China (English)

    黄国胜; 李相波; 邢路阔; 王应发

    2013-01-01

    为了探讨冷喷涂制备锌镍合金的可行性及其制成的涂层的耐蚀性,采用机械合金化制备了不同镍含量的锌镍合金粉末,将其冷喷涂于Q235钢表面制成锌镍合金层,通过动电位极化测试、扫描电镜(SEM)、X射线衍射仪(XRD)等研究了其在海水中的腐蚀行为.结果表明:机械合金化能使部分锌镍粉末合金化,冷喷涂过程使合金化程度进一步提高;锌镍合金冷喷涂层在海水中浸泡时,锌首先被溶解生成致密产物,产物膜下形成镍的富集层,延缓了涂层的腐蚀速率;镍的加入可以提高涂层的稳定电位,降低涂层腐蚀速率,但镍含量过高会使涂层发生腐蚀微电池作用,含镍15%的冷喷涂锌镍合金层的耐蚀性最佳;镍可以稳定Zn(OH)2,抑制其向ZnO转化,使得冷喷涂层腐蚀形貌均匀致密.%Zn-Ni alloy powder with different Ni contents was prepared by mechanical alloying. Resultant Zn-Ni powder was then cold-sprayed onto the surface of Q235 steel to afford Zn-Ni alloy coatings. The corrosion resistance of Zn-Ni alloy coatings in seawater was evaluated by potentiodynamic polarization test. The morphology and microstructure of as - prepared Zn-Ni alloy powder and coatings as well as the corroded surface morphology and corroded product composition of the coatings were analyzed by means of scanning electron microscopy and X - ray diffraction. It was found that mechanical alloying led to partial alloying of Zn-Ni powder, and cold - spraying helped to promote the alloying of the Zn-Ni powder. When the Zn-Ni alloy coatings were immersed in seawater, Zn was preferentially dissolved to form a compact top layer while a Ni - rich layer was formed at the sub-surface thereby retarding the corrosion process of the alloy coatings. Incorporated Ni was able to increase the stabilization potential and reduce the corrosion rate of the alloy coatings. However , excessive incorporation of Ni led to micro - cell corrosion of the

  8. Effect of Molybdate Ions on the Corrosion Behaviour of Ti Alloys

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    Titanium alloys are extensively used in power, chemical and petroleum industries as constructional materials for vessels and heat transfer tubes. Moreover they are candidate materials for nuclear waste disposal. These alloys have superior resistance to localized forms of corrosion compared to stainless steels and Ni-base alloys. However, this resistance is not as remarkable in crevice corrosion conditions in some aggressive media. Electrochemical corrosion tests were conducted on two ASTM Ti grades namely, Ti-2 and Ti-12 in extremely low pH acidic environment. Results indicated that Ti-2 has less resistance to both general and crevice corrosion attack than Ti-12.Both alloys possess better resistance to general corrosion than to crevice corrosion. Also, results showed that the molybdate addition improves remarkably the resistance of Ti-2 to both types of attack. The increase of molybdate ions concentration from 0.03 mol/L to 0.15 mol/L made Ti-2 to be as resistant as, or somewhat higher than, Ti-12. The elecrochemical findings were further supplemented by optical examination of the corroded surface.

  9. Surface Composition and Corrosion Property of TiNi Alloys Coated with Tantalum Films

    Institute of Scientific and Technical Information of China (English)

    Yan CHENG; Wei CAI; Liancheng ZHAO

    2004-01-01

    Multi-arc ion plating method was employed to coat TiNi alloys with Ta in order to improve radiopacity and corrosion resistance property. The surface composition, corrosion resistance property and Ni ions release amount of TiNi alloys coated with Ta films compared with TiNi alloys, are investigated by means of X-ray photoelectron spectrometry (XPS), electrochemical measurements and atomic absorption spectrophotometry (AAS), respectively. The results show that the coated surface composition is composed of Ta and O and the corrosion resistance is improved, whereas the Ni ions release amount of the coated sample is lower than that of the uncoated samples in the whole immersion period, indicating that Ta coating can improve the biocompatibility of TiNi alloys.

  10. The mechanism of corrosion of palladium-silver binary alloys in artificial saliva.

    Science.gov (United States)

    Joska, L; Marek, M; Leitner, J

    2005-05-01

    Palladium dental casting alloys are alternatives to gold alloys. The aim of this study was to determine the electrochemical behaviour and the corrosion mechanism of binary silver-palladium alloys. Seven binary silver-palladium alloys and pure palladium and silver were tested in a model saliva solution. Electrochemical tests included corrosion potential, polarization resistance, and potentiodynamic polarization measurements. The corrosion products, which may be theoretically formed, were determined by thermodynamic calculation. The behaviour of silver and silver-rich alloys was dominated by the preferential formation of a thiocyanate surface layer, which controlled the free corrosion potential. Palladium dissolved in the form of a thiocyanate complex, but the surface became passivated by either palladium oxide or solid palladium thiocyanate layer, the thermodynamic calculations indicating preference for the oxide. Palladium-rich alloys showed evidence of silver depletion of the surface, resulting in behaviour similar to palladium. Examination of binary silver-palladium alloys has made possible determination of the role of the components of the alloys and model saliva in the corrosion behaviour. The findings are applicable to the more complex commercial dental alloys containing silver and palladium as major components.

  11. Selection of Corrosion Resistant Materials for Nuclear Waste Repositories

    Energy Technology Data Exchange (ETDEWEB)

    R.B. Rebak

    2006-08-28

    Several countries are considering geological repositories to dispose of nuclear waste. The environment of most of the currently considered repositories will be reducing in nature, except for the repository in the US, which is going to be oxidizing. For the reducing repositories, alloys such as carbon steel, stainless steels and titanium are being evaluated. For the repository in the US, some of the most corrosion resistant commercially available alloys are being investigated. This paper presents a summary of the behavior of the different materials under consideration for the repositories and the current understanding of the degradation modes of the proposed alloys in ground water environments from the point of view of general corrosion, localized corrosion and environmentally assisted cracking.

  12. Selection of Corrosion Resistant Materials for Nuclear Waste Repositories

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B

    2006-06-01

    Several countries are considering geological repositories to dispose of nuclear waste. The environment of most of the currently considered repositories will be reducing in nature, except for the repository in the US, which is going to be oxidizing. For the reducing repositories alloys such as carbon steel, stainless steels and titanium are being evaluated. For the repository in the US, some of the most corrosion resistant commercially available alloys are being investigated. This paper presents a summary of the behavior of the different materials under consideration for the repositories and the current understanding of the degradation modes of the proposed alloys in ground water environments from the point of view of general corrosion, localized corrosion and environmentally assisted cracking.

  13. Effects of High Magnetic Field on Solidification and Corrosion Behaviors of Magnesium Alloy

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The solidification behaviors of AZ61 magnesium alloy under a high magnetic field were studied. The corrosion property of AZ61 alloy was investigated in a solution of 3.5 mol/L NaCl by measuring electrochemical polarization. The results show that the high magnetic field can refine microstructure and benefit aluminum transfer.The crystal of α-Mg is induced to orient with their c-axis parallel to the magnetic field. The corrosion studies indicate that different crystal plane of magnesium has different corrosion property. The passivating films on the a- and b-planes have higher corrosion resistance than that on the c-plane. Aligned structure affects the corrosion property of AZ61 magnesium alloy.

  14. Corrosion Behavior and Durability of Low-Alloy Steel Rebars in Marine Environment

    Science.gov (United States)

    Liu, Ming; Cheng, Xuequn; Li, Xiaogang; Yue, Pan; Li, Jun

    2016-10-01

    The corrosion resistance of Cr-modified low-alloy steels and HRB400 carbon steel was estimated using the open-circuit potential, potentiodynamic polarization, electrochemical impedance spectroscopic, and weight loss methods in simulated concrete pore solution. Results show that Cr-modified steels exhibit a higher corrosion resistance with a higher critical chloride level (CTL), lower corrosion current density, and higher impedance than carbon steel. The CTL of the steels significantly reduces with increasing temperature. Weight loss measurement shows that the Cr-modified steels exhibit low corrosion rates and small corrosion pitting. The primary constituents of the corrosion scales are Fe2O3, Fe3O4, β-FeOOH, γ-FeOOH, and α-FeOOH. A large amount of α-FeOOH could be detected in the Cr-modified steel corrosion products. Moreover, the Cr-modified steels demonstrate a higher durability than HRB400 carbon steel.

  15. Effects of Mg content on pore structure and electrochemical corrosion behaviors of porous Al-Mg alloys

    Institute of Scientific and Technical Information of China (English)

    何文远; 肖逸锋; 吴靓; 许艳飞; 钱锦文; 贺跃辉; 郑学军

    2016-01-01

    Porous Al-Mg alloys with different nominal compositions were successfully fabricated via elemental powder reactive synthesis, and the phase composition, pore structure, and corrosion resistance were characterized with X-ray diffractometer, scanning electron microscope and electrochemical analyzer. The volume expansion ratio, open porosity and corrosion resistance in 3.5% (mass fraction) NaCl aqueous solution of the alloys increase at first and then decrease with the increase of Mg content. The maxima of volume expansion ratio and open porosity are 18.3% and 28.1% for the porous Al-56%Mg (mass fraction) alloy, while there is the best corrosion resistance for the porous Al-37.5% Mg (mass fraction) alloy. The pore formation mechanism can be explained by Kirkendall effect, and the corrosion resistance can be mainly affected by the phase composition for the porous Al-Mg alloys. They would be of the potential application for filtration in the chloride environment.

  16. Steam assisted oxide growth on aluminium alloys using oxidative chemistries: Part II corrosion performance

    Science.gov (United States)

    Din, Rameez Ud; Jellesen, Morten Stendahl; Ambat, Rajan

    2015-11-01

    Surface treatment of aluminium alloys using steam with oxidative chemistries, namely KMnO4 and HNO3 resulted in accelerated growth of oxide on aluminium alloys. Detailed investigation of the corrosion performance of the treated surfaces was carried out using potentiodynamic polarisation and standard industrial test methods such as acetic acid salt spray (AASS) and filiform corrosion on commercial AA6060 alloy. Barrier properties of the film including adhesion were evaluated using tape test under wet and dry conditions. Electrochemical results showed reduced cathodic and anodic activity, while the protection provided by steam treatment with HNO3 was a function of the concentration of NO3- ions. The coating generated by inclusion of KMnO4 showed highest resistance to filiform corrosion. Overall, the performance of the steam treated surfaces under filiform corrosion and AASS test was a result of the local coverage of the alloy microstructure resulting from steam containing with KMnO4 and HNO3.

  17. Corrosion behavior of Al6061 alloy weldment produced by friction stir welding process

    Directory of Open Access Journals (Sweden)

    Farhad Gharavi

    2015-07-01

    Full Text Available In this work, the corrosion behavior of welded lap joints of AA6061-T6 aluminum alloy produced by friction stir welding process has been investigated. Corrosion properties of welded lap joints were studied by cyclic polarization and electrochemical impedance spectroscopy tests. All tests were performed in an aerated 0.6 mol L−1 NaCl aqueous solution with pH = 6.5 at a temperature of 30 °C to characterize corrosion morphology and realize corrosion features of weld regions as opposed to the parent alloy. The microstructure of weld nugget (WN, heated affected zone (HAZ, and parent alloy were analyzed using scanning electron microscopy and energy dispersive spectroscopy. The experimental results indicated that the welding process has a major effect on the corrosion resistance, which possibly associated to the break-down and dissolution of intermetallic particles. It is supposed that an increasing in intermetallic distributed throughout the matrix of weld regions increases the galvanic corrosion couples. Furthermore, by decreasing the grain size in the weld regions, the susceptibility to corrosion is enhanced. The pitting corrosion and intergranular attack are the dominant corrosion types in the weld regions and the parent alloy.

  18. EFFECT OF THE HEAT AND SURFACE LASER TREATMENT ON THE CORROSION DEGRADATION OF THE Mg-Al ALLOYS

    Directory of Open Access Journals (Sweden)

    Leszek A. Dobrzański

    2011-09-01

    Full Text Available In this paper there is presented the corrosion behavior of the cast magnesium alloys as cast state, after heat and laser treatment. Pitting corrosion resistance of the analyzed alloys was carried out using the potentiodynamic electrochemical method (direct current, based on a anodic polarization curve. On the basis of the achieved anodic polarization curves, using the Tefel extrapolation method near to the corrosion potential, the quantitative data were determined, which describe the electrochemical corrosion process of the investigated alloys: value of the corrosion potential Ecorr (mV, polarization resistance RP (kohm.cm2, corrosion current density icorr (10-6A/cm2, corrosion rate Vcorr (mm/year as well the mass loss Vc (g/m2<.

  19. Corrosion Behavior of Alloy 22 in Oxalic Acid and Sodium Chloride Solutions

    Energy Technology Data Exchange (ETDEWEB)

    Day, S D; Whalen, M T; King, K J; Hust, G A; Wong, L L; Estill, J C; Rebak, R B

    2003-06-24

    Nickel based Alloy 22 (NO6022) is extensively used in aggressive industrial applications, especially due to its resistance to localized corrosion and stress corrosion cracking in high chloride environments. The purpose of this work was to characterize the anodic behavior of Alloy 22 in oxalic acid solution and to compare its behavior to sodium chloride (NaCl) solutions. Standard electrochemical tests such as polarization resistance and cyclic polarization were used. Results show that the corrosion rate of Alloy 22 in oxalic acid solutions increased rapidly as the temperature and the acid concentration increased. Extrapolation studies show that even at a concentration of 10{sup -4}M oxalic acid, the corrosion rate of Alloy 22 would be higher in oxalic acid than in 1 M NaCl solution. Alloy 22 was not susceptible to localized corrosion in oxalic acid solutions. Cyclic polarization tests in 1 M NaCl showed that Alloy 22 was susceptible to crevice corrosion at 90 C but was not susceptible at 60 C.

  20. Effect of zirconium content on the microstructure, physical properties and corrosion behavior of Ti alloys

    Energy Technology Data Exchange (ETDEWEB)

    Han, Mi-Kyung; Hwang, Moon-Jin [Department of Dental Materials and MRC for Biomineralization Disorders, School of Dentistry, Chonnam National University, Gwangju 500-757 (Korea, Republic of); Yang, Min-Soo; Yang, Hong-So [Department of Prosthodontics, School of Dentistry, Chonnam National University, Gwangju 500-757 (Korea, Republic of); Song, Ho-Jun [Department of Dental Materials and MRC for Biomineralization Disorders, School of Dentistry, Chonnam National University, Gwangju 500-757 (Korea, Republic of); Park, Yeong-Joon, E-mail: yjpark@jnu.ac.kr [Department of Dental Materials and MRC for Biomineralization Disorders, School of Dentistry, Chonnam National University, Gwangju 500-757 (Korea, Republic of)

    2014-10-20

    A series of Ti–xZr alloys with Zr contents ranging from 5 to 20 wt% was prepared and the effects of Zr addition on the microstructure, physical properties, and corrosion behavior of Ti alloys were investigated. The phase and microstructures were characterized using X-ray diffractometry (XRD), optical microscopy, scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The Ti–xZr alloys exhibited α-Ti structure at Zr content of 20 wt% or below. Commercially pure titanium (cp-Ti) was used as a control. We also investigated the effects of alloying element Zr on the mechanical property, oxidation protection ability, and corrosion behavior of Ti–xZr binary alloys. The physical properties and corrosion behavior of Ti–xZr alloys were sensitive to the Zr content. The addition of Zr did contribute to the hardening of cp-Ti due to solid-solution strengthening of α-Ti. Ti–xZr alloys containing up to 10 wt% Zr resulted in good oxidation resistance, while Ti–xZr alloys with above 10 wt% Zr demonstrated higher oxidation weight gain than cp-Ti. Electrochemical experiments showed that the Ti–xZr alloys exhibited better corrosion resistance compared to that of cp-Ti.

  1. In vitro corrosion behavior and cellular response of thermally oxidized Zr-3Sn alloy

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, F.Y.; Wang, B.L.; Qiu, K.J. [Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001 (China); Li, H.F. [Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Li, L. [Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001 (China); Zheng, Y.F., E-mail: yfzheng@pku.edu.cn [Center for Biomedical Materials and Engineering, Harbin Engineering University, Harbin 150001 (China); Department of Materials Science and Engineering, College of Engineering, Peking University, Beijing 100871 (China); Han, Y. [State Key Laboratory for Mechanical Behavior of Materials, Xian Jiaotong University, Xian 710049 (China)

    2013-01-15

    Highlights: Black-Right-Pointing-Pointer A main monoclinic ZrO{sub 2} layer formed on ZrSn alloy after thermal oxidation. Black-Right-Pointing-Pointer Corrosion resistance of ZrSn alloy was improved with thermal oxidation. Black-Right-Pointing-Pointer The oxide layer inhibited the release of the ions into the mediums. Black-Right-Pointing-Pointer Oxidized ZrSn alloy exhibited an excellent in vitro biocompatibility. - Abstract: In this study, ZrSn alloy was thermally oxidized at 600 Degree-Sign C for 3 h and its morphological and structural characteristics, corrosion behavior, ion release and in vitro cytocompatibility were studied to evaluate the feasibility of applying it as dental implant. After oxidation, a dense black oxide layer formed on ZrSn alloy surface, which consisted of predominant monoclinic zirconia and a few non-stoichiometric oxides. The scratching and water contact angle test results demonstrated that the oxide layer exhibited good adhesion strength and similar hydrophilicity to zirconia. The oxidized ZrSn alloy showed higher corrosion resistance, as indicated by far lower corrosion current density and passive current density compared to pure Ti and untreated ZrSn alloy in artificial saliva with and without H{sub 2}O{sub 2}. The amount of ions released from the oxidized ZrSn alloy was much lower than that dissolved from pure Ti in simulated corrosive oral mediums. Moreover, the oxidized ZrSn alloy did not present any significant toxic effect to both osteoblast-like cells and fibroblast cells, and osteoblast-like cells could adhere well onto the surface and exhibited a good proliferative pattern. The combination of improved surface properties, superior corrosion resistance and good biocompatibility made the oxidized ZrSn alloy promising for oral implantology application.

  2. Corrosion of Mechanically Alloyed Nanostructured FeAl Intermetallic Powders

    Directory of Open Access Journals (Sweden)

    A. Torres-Islas

    2012-01-01

    Full Text Available The corrosion behavior of the Fe40Al60 nanostructured intermetallic composition was studied using electrochemical impedance spectroscopy (EIS and linear polarization resistance (LPR techniques with an innovative electrochemical cell arrangement. The Fe40Al60 (% at intermetallic composition was obtained by mechanical alloying using elemental powders of Fe (99.99% and Al (99.99%. All electrochemical testing was carried out in Fe40Al60 particles that were in water with different pH values. Temperature and test time were also varied. The experimental data was analyzed as an indicator of the monitoring of the particle corrosion current density icorr. Different oxide types that were formed at surface particle were found. These oxides promote two types of surface corrosion mechanisms: (i diffusion and (ii charge transfer mechanisms, which are a function of icorr behavior of the solution, pH, temperature, and test time. The intermetallic was characterized before and after each test by transmission electron microscopy. Furthermore, the results show that at the surface particles uniform corrosion takes place. These results confirm that it is possible to sense the nanoparticle corrosion behavior by EIS and LPR conventional electrochemical techniques.

  3. Processing Technology and Corrosion Resistance of Silane Film on Aluminum Alloy%铝合金表面新型硅烷膜的制备及表面形貌研究

    Institute of Scientific and Technical Information of China (English)

    汪亮; 宣天鹏; 周赟; 张万利

    2012-01-01

    通过正交试验确定了铝合金表面硅烷膜技术的最佳工艺参数.在基础配方上制备了硅烷膜,利用硫酸铜点滴试验评价了工艺参数,结果表明,水解温度、硅烷浓度、醇水比及pH主要影响了硅烷溶液的水解与缩合反应.分析了硅烷膜的表面形貌、初步探讨了硅烷膜的耐腐蚀性能,结果表明,硅烷膜均匀、致密,具有比铬酸盐钝化更优的防护作用.%The optimum process parameters of silane film on aluminum alloy were obtained by orthogonal experiment. The silane film was prepared and its corrosion resistance was evaluated by dropping corrosion test. Results indicated that the hydrolysis and condensation reaction of silane solution were mainly affected by hydrolysis temperature, silane concentration, alcohol-water ratio and pH value. The surface morphology of silane films was analyzed, and the corrosion resistance of silane films was determined. The silane film was uniform, compact and had a better corrosion resistance than chromate conversion coating.

  4. Effect of hydrogen on the corrosion behavior of the Mg–xZn alloys

    Directory of Open Access Journals (Sweden)

    Yingwei Song

    2014-09-01

    Full Text Available Hydrogen evolution reaction is inevitable during the corrosion of Mg alloys. The effect of hydrogen on the corrosion behavior of the Mg–2Zn and Mg–5Zn alloys is investigated by charging hydrogen treatment. The surface morphologies of the samples after charging hydrogen were observed using a scanning electron microscopy (SEM and the corrosion resistance was evaluated by polarization curves. It is found that there are oxide films formed on the surface of the charged hydrogen samples. The low hydrogen evolution rate is helpful to improve the corrosion resistance of Mg alloys, while the high hydrogen evolution rate can increases the defects in the films and further deteriorates their protection ability. Also, the charging hydrogen effect is greatly associated with the microstructure of Mg substrate.

  5. Corrosion behavior of Ti-Ag alloys used in dentistry in lactic acid solution

    Science.gov (United States)

    Takahashi, Masatoshi; Kikuchi, Masafumi; Takada, Yukyo

    2011-02-01

    The purpose of this study was to evaluate the corrosion resistance of experimental Ti-Ag alloys used as dental materials. An elution test and a rest-potential measurement of alloys with 5-30 mass.% Ag were performed in a 1 % lactic acid solution. The amount of Ti ions released from the α phase of the Ti-Ag alloys decreased as the Ag concentration increased. TiAg present in the alloys dissolved preferentially, but Ti2Ag did not. The rest potentials of the Ti-Ag alloys were significantly higher than that of pure titanium. The elution test and the rest-potential measurement revealed that the Ti-Ag alloys, which formed a single α-titanium structure or contained a titanium and Ti2Ag, had excellent corrosion resistance that was comparable or superior to that of pure titanium.

  6. Corrosion damage evolution and residual strength of corroded aluminum alloys

    Institute of Scientific and Technical Information of China (English)

    Youhong Zhang; Guozhi Lv; Hui Wang; Bomei Si; Yueliang Cheng

    2008-01-01

    The LY12CZ aluminum alloy specimens were eurroded under the conditions of different test temperatures and exposure durations. After corrosion exposure, fatigue tests were performed. Scanning electron microscopy and optical microscope analyses on corrosion damage were carried out. The definition of surface corrosion damage ratio was provided to describe the extent of surface corrosion damage. On the basis of the measured data sets of the corrosion damage ratio, the probabilistic model of corrosion damage evolution was built. The corrosion damage decreased the fatigue life by a factor of about 1.25 to 2.38 and the prediction method of residual strength of the corroded structure was presented.

  7. Corrosion behaviour of ion implanted aluminium alloy in 0.1 M NaCl electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Chu, J.W.; Evans, P.J. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia); Sood, D.K. [Royal Melbourne Inst. of Tech., VIC (Australia)

    1993-12-31

    Aluminum and its alloys are widely used in industry because of their light weight, high strength and good corrosion resistance which is due to the formation of a protective oxide layer. However, under saline conditions such as those encountered in marine environments, this group of metals are vulnerable to localised degradation in the form of pitting corrosion. This type of corrosion involves the adsorption of an anion, such as chlorine, at the oxide solution interface. Ion implantation of metal ions has been shown to improve the corrosion resistance of a variety of materials. This effect occurs : when the implanted species reduces anion adsorption thereby decreasing the corrosion rate. In this paper we report on the pitting behavior of Ti implanted 2011 Al alloy in dilute sodium chloride solution. The Ti implanted surfaces exhibited an increased pitting potential and a reduced oxygen uptake. 5 refs., 3 figs.

  8. In vitro corrosion behavior and cellular response of thermally oxidized Zr-3Sn alloy

    Science.gov (United States)

    Zhou, F. Y.; Wang, B. L.; Qiu, K. J.; Li, H. F.; Li, L.; Zheng, Y. F.; Han, Y.

    2013-01-01

    In this study, ZrSn alloy was thermally oxidized at 600 °C for 3 h and its morphological and structural characteristics, corrosion behavior, ion release and in vitro cytocompatibility were studied to evaluate the feasibility of applying it as dental implant. After oxidation, a dense black oxide layer formed on ZrSn alloy surface, which consisted of predominant monoclinic zirconia and a few non-stoichiometric oxides. The scratching and water contact angle test results demonstrated that the oxide layer exhibited good adhesion strength and similar hydrophilicity to zirconia. The oxidized ZrSn alloy showed higher corrosion resistance, as indicated by far lower corrosion current density and passive current density compared to pure Ti and untreated ZrSn alloy in artificial saliva with and without H2O2. The amount of ions released from the oxidized ZrSn alloy was much lower than that dissolved from pure Ti in simulated corrosive oral mediums. Moreover, the oxidized ZrSn alloy did not present any significant toxic effect to both osteoblast-like cells and fibroblast cells, and osteoblast-like cells could adhere well onto the surface and exhibited a good proliferative pattern. The combination of improved surface properties, superior corrosion resistance and good biocompatibility made the oxidized ZrSn alloy promising for oral implantology application.

  9. Corrosion performance of Fe-Cr-Al and Fe aluminide alloys in complex gas environments

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K. [Argonne National Lab., IL (United States); Johnson, R.N. [Pacific Northwest Lab., Richland, WA (United States)

    1995-05-01

    Alumina-forming structural alloys can offer superior resistance to corrosion in the presence of sulfur-containing environments, which are prevalent in coal-fired fossil energy systems. Further, Fe aluminides are being developed for use as structural materials and/or cladding alloys in these systems. Extensive development has been in progress on Fe{sub 3}Al-based alloys to improve their engineering ductility. In addition, surface coatings of Fe aluminide are being developed to impart corrosion resistance to structural alloys. This paper describes results from an ongoing program that is evaluating the corrosion performance of alumina-forming structural alloys, Fe-Al and Fe aluminide bulk alloys, and Fe aluminide coatings in environments typical of coal-gasification and combustion atmospheres. Experiments were conducted at 650-1000{degrees}C in simulated oxygen/sulfur gas mixtures. Other aspects of the program are corrosion evaluation of the aluminides in the presence of HCl-containing gases. Results are used to establish threshold Al levels in the alloys for development of protective alumina scales and to determine the modes of corrosion degradation that occur in the materials when they are exposed to S/Cl-containing gaseous environments.

  10. Effect of Sodium Molybdate Inhibitor on Corrosion Resistance of 5083 Aluminum Alloy Used for Drone%钼酸钠对靶用5083铝合金耐蚀性能影响的研究

    Institute of Scientific and Technical Information of China (English)

    杨志成; 周宽; 田志强

    2016-01-01

    目的:提高靶用5083铝合金材料的耐蚀性。方法分别运用阳极极化、交流阻抗及EDS等试验技术研究钼酸钠对5083铝合金在3%氯化钠溶液中的耐蚀性能影响。结果钼酸钠加入3%氯化钠溶液以后,该铝合金的腐蚀电位下降,点蚀电位与腐蚀电位分离,维钝电流减小,阻抗值增大,抗点蚀能力提高。结论钼酸钠对5083铝合金产生缓蚀作用。%Objective To improve the corrosion resistance of 5083 aluminum alloy used for drone.Methods The polariza-tion, electrochemical impedance spectrum and energy dispersive spectrometer were employed to study the effect of sodium mo-lybdate inhibitor on the corrosion resistance of 5083 aluminum alloy in 3% NaCl solution.Results After addition of sodium molybdate in the 3% NaCl solution, the corrosion potential was decreased and separated from the pitting potential, the passi-vated current was reduced, the impedance was increased, and the capability of inhibiting pitting was promoted.Conclusion So-dium molybdate had corrosion inhibition effect on 5083 aluminum alloy.

  11. Corrosion Behavior of Ti-13Nb-13Zr and Ti-6Al-4V Alloys for Biomaterial Application

    Energy Technology Data Exchange (ETDEWEB)

    Saji, Viswanathan S.; Jeong, Yong Hoon; Choe, Han Cheol [Chosun University, Gwangju (Korea, Republic of); Yu, Jin Woo [Shingyeong University, Hwaseong (Korea, Republic of)

    2010-02-15

    Ti-13Nb-13Zr (TNZ) alloy has attracted considerable research attention in the last decade as a suitable substitute for the commercially used Ti-6Al-4V (TAV) alloy for orthopedic and dental implant applications. Hence, in the present work, a comparative evaluation has been performed on the electrochemical corrosion behavior of TNZ and TAV alloys in 0.9 wt.% NaCl solution. The result of the study showed that both the alloys had similar electrochemical behavior. The corrosion resistance of TAV alloy is found to be marginally superior to that of TNZ alloy.

  12. 锌镍合金镀工艺优化及镀层耐腐蚀性的研究%Research on Process Optimization of Zn-Ni Alloy Plating and Coating Corrosion Resistance

    Institute of Scientific and Technical Information of China (English)

    陈伟; 唐凌燕; 周英; 陈刚

    2015-01-01

    Objective To study the corrosion resistance of Zn-Ni alloy coating. Methods By orthogonal test method, the Zn-Ni alloy electroplating technology was optimized, and the plating solution formula was obtained. The corrosion resistance of the opti-mized Zn-Ni alloy plating was evaluated by neutral salt spray test, and compared to those of the galvanized layer and cadmium plat-ing layer. The influence of the main salt, complexing agent, pH value, current density and temperature on the coating corrosion re-sistance was analyzed. Results The optimal formula was:zinc oxide 6~14 g/L, nickel sulfate 20~30 g/L, sodium hydroxide 100~140 g/L, brightener 4~6 g/L, and complexing agent 50~70 g/L. The Zn-Ni alloy coating obtained using this formula had a white rust occurrence time of more than 720 hours in the neutral salt spray test. Conclusion The Zn-Ni alloy coating had excellent corro-sion resistance, superior to those of zinc and cadmium plating layer.%目的:研究锌镍合金镀层的耐腐蚀性能。方法通过正交试验法,对锌镍合金电镀工艺进行优化,获得镀液配方。通过中性盐雾试验评判优化后的锌镍合金镀层的耐腐蚀性能,并与镀锌层和镀镉层进行对比。分析主盐、络合剂、pH值、电流密度、温度等对镀层耐腐蚀性的影响。结果最优配方为:氧化锌6~14 g/L,硫酸镍20~30 g/L,氢氧化钠100~140 g/L,光亮剂4~6 g/L,络合剂50~70 g/L。该配方获得的锌镍合金镀层在中性盐雾实验中,出白锈的时间可以达到720 h以上。结论锌镍合金镀层的耐腐蚀性优良,优于镀锌层和镀镉层。

  13. Stress corrosion evaluation of powder metallurgy aluminum alloy 7091 with the breaking load test method

    Science.gov (United States)

    Domack, Marcia S.

    1987-01-01

    The stress corrosion behavior of the P/M aluminum alloy 7091 is evaluated in two overaged heat treatment conditions, T7E69 and T7E70, using an accelerated test technique known as the breaking load test method. The breaking load data obtained in this study indicate that P/M 7091 alloy is highly resistant to stress corrosion in both longitudinal and transverse orientations at stress levels up to 90 percent of the material yield strength. The reduction in mean breaking stress as a result of corrosive attack is smallest for the more overaged T7E70 condition. Details of the test procedure are included.

  14. Electrochemical Corrosion Behavior of the DLC Coated and Uncoated NiTi Alloys

    Institute of Scientific and Technical Information of China (English)

    Jiehe SUI; Wei CAI; Liancheng ZHAO

    2006-01-01

    A dense and well-adhered diamond-like carbon(DLC)coating was prepared on the nickel-titanium(NiTi)alloys by plasma immersion ion implantation and deposition(PⅢD). Potentiodynamic polarization tests indicated the corrosion resistance of the NiTi alloys was markedly improved by the DLC coating. The Ni ions release of the NiTi alloys was effectively blocked by the DLC coating.

  15. Combined Corrosion and Wear of Aluminium Alloy 7075-T6

    NARCIS (Netherlands)

    Liu, Y.; Mol, J.M.C.; Janssen, G.C.A.M.

    2016-01-01

    The aluminium alloy 7075-T6 is widely used in engineering. In some applications, like slurry transport, corrosion and abrasion occur simultaneously, resulting in early material failure. In the present work, we investigated the combined effect of corrosion and wear on the aluminium alloy 7075-T6. We

  16. Combined Corrosion and Wear of Aluminium Alloy 7075-T6

    NARCIS (Netherlands)

    Liu, Y.; Mol, J.M.C.; Janssen, G.C.A.M.

    2016-01-01

    The aluminium alloy 7075-T6 is widely used in engineering. In some applications, like slurry transport, corrosion and abrasion occur simultaneously, resulting in early material failure. In the present work, we investigated the combined effect of corrosion and wear on the aluminium alloy 7075-T6. We

  17. Development of Laser Surface Technologies for Anti-Corrosion on Magnesium Alloys: a Review

    Science.gov (United States)

    Sun, Rujian; Guan, Yingchun; Zhu, Ying

    2016-03-01

    Magnesium (Mg) alloys have been increasingly used in industries and biomaterial fields due to low density, high specific strength and biodegradability. However, poor surface-related properties are major factors that limit their practical applications. This paper mainly focuses on laser-based anti-corrosion technologies for Mg alloys, beginning with a brief review of conventional methods, and then demonstrates the feasibility of laser surface technologies including laser surface melting (LSM), laser surface alloying (LSA), laser surface cladding (LSC) and laser shock peening (LSP) in achieving enhancement of corrosion resistance. The mechanism and capability of each technique in corrosion resistance is carefully discussed. Finally, an outlook of the development of laser surface technology for Mg alloy is further concluded, aiming to serve as a guide for further research both in industry applications and biomedical devices.

  18. Galvanic corrosion of selected dental alloys.

    Science.gov (United States)

    Karov, J; Hinberg, I

    2001-03-01

    Samples prepared from three different amalgam brands were coupled to two gold alloys and orthodontic brackets. In the resulting galvanic cells, the amalgam coupled to gold were anodic, exhibiting galvanic current densities about one order of magnitude higher than the uncoupled corrosion current densities of 0.2-0.5 microA. Coupling amalgams to orthodontic brackets resulted in galvanic current densities of the same magnitude as the uncoupled samples. Corrosion current densities at the anode were found to be up to six times higher than the measured galvanic current densities. Brushing caused transient increases in galvanic current densities that decayed within 100 s to the previous steady state levels. Brushing of amalgam/bracket couples, caused an anodic peak followed by brief polarization reversal during which the brackets were anodic.

  19. Coal Ash Corrosion Resistant Materials Testing

    Energy Technology Data Exchange (ETDEWEB)

    D. K. McDonald; P. L. Daniel; D. J. DeVault

    2003-08-31

    In April 1999, three identical superheater test sections were installed into the Niles Unit No.1 for the purpose of testing and ranking the coal ash corrosion resistance of candidate superheater alloys. The Niles boiler burns high sulfur coal (3% to 3.5%) that has a reasonably high alkali content, thus the constituents necessary for coal ash corrosion are present in the ash. The test sections were controlled to operate with an average surface metal temperature from approximately 1060 F to 1210 F which was well within the temperature range over which coal ash corrosion occurs. Thus, this combination of aggressive environment and high temperature was appropriate for testing the performance of candidate corrosion-resistant tube materials. Analyses of the deposit and scale confirmed that the aggressive alkali-iron-trisulfate constituent was present at the metal surface and active in tube metal wastage. The test sections were constructed so that the response of twelve different candidate tube and/or coating materials could be studied. The plan was to remove and evaluate one of the three test sections at time intervals of 1 year, 3 years, and 5 years. This would permit an assessment of performance of the candidate materials as a function of time. This report provides the results of the evaluation of Test Section C, including the samples that remained in the Test Section for the full exposure period as well as those that were removed early. The analysis of Test Section C followed much the same protocol that was employed in the assessment of Test Section A. Again, the focus was on determining and documenting the relative corrosion rates of the candidate materials. The detailed results of the investigation are included in this report as a series of twelve appendices. Each appendix is devoted to the performance of one of the candidate alloys. The table below summarizes metal loss rate for the worst case sample of each of the candidate materials for both Test Sections A and C

  20. Corrosion of copper alloys in sulphide containing district heting systems

    DEFF Research Database (Denmark)

    Thorarinsdottir, R.I.; Maahn, Ernst Emanuel

    1999-01-01

    Copper and some copper alloys are prone to corrosion in sulphide containing geothermal water analogous to corrosion observed in district heating systems containing sulphide due to sulphate reducing bacteria. In order to study the corrosion of copper alloys under practical conditions a test...... was carried out at four sites in the Reykjavik District Heating System. The geothermal water chemistry is different at each site. The corrosion rate and the amount and chemical composition of deposits on weight loss coupons of six different copper alloys are described after exposure of 12 and 18 months...

  1. Corrosion and mechanical properties of AM50 magnesium alloy after being modified by 1 wt.% rare earth element gadolinium

    Institute of Scientific and Technical Information of China (English)

    杨淼; 刘耀辉; 刘家安; 宋雨来

    2014-01-01

    In order to improve the corrosion and mechanical properties of AM50 magnesium alloy, 1 wt.% Gd was used to modify the AM50 magnesium alloy. The microstructure, corrosion and mechanical properties were evaluated by X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), electrochemical and mechanical stretch methods. The results indicated that β-Mg17Al12 phase decreased and Al2Gd3 and Al0.4GdMn1.6 phase existed after Gd addition. Because of the Gd addition, the grain of AM50 magnesium alloy was refined significantly, which improved the tensile strength of AM50 magnesium al-loy. The decreasing ofβ phase improved the corrosion resistance of the magnesium alloy. The fracture mechanism of the Gd modified AM50 magnesium alloy was quasi-cleavage fracture. The corrosion residual strength (CRS) of AM50 magnesium alloy was im-proved after 1 wt.% Gd addition.

  2. Corrosion-resistant tube materials for extended life of openings in recovery boilers

    Energy Technology Data Exchange (ETDEWEB)

    Paul, L.D.; Danielson, M.J.; Harper, S.L. (Babcock and Wilcox Co., Alliance, OH (United States). Research and Development Div.); Barna, J.L. (Babcock and Wilcox Co., Barberton, OH (United States). Fossil Power Div.)

    1993-08-01

    The corrosive conditions causing rapid corrosion of Type 304L stainless steel in tube openings have been duplicated in the laboratory. Alternate materials also have been tested, and some show improved corrosion resistance over Type 304L. Alloy 825 and Alloy 625 composite tubing and Alloy 600 and Alloy 625 weld overlay materials all show promise as a replacement for Type 304L in tube openings. All recovery boilers designed or operated at 8.375 MPa (1,200 psi) and above should consider using these replacement materials for tube openings.

  3. Corrosion-Fatigue Cracking in Al 7075 Alloys

    Science.gov (United States)

    2014-12-09

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/6355--14-9582 Corrosion -Fatigue Cracking in Al 7075 Alloys December 9, 2014 P.S. Pao...PERSON 19b. TELEPHONE NUMBER (include area code) b. ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 17. LIMITATION OF ABSTRACT Corrosion -Fatigue Cracking in Al...Memorandum Report Corrosion -fatigue Aluminum alloys Environmental effect October 2011 – September 2014 63-2634-A4 Unclassified Unlimited Unclassified

  4. High-temperature corrosion behavior of coatings and ODS alloys based on Fe{sub 3}Al

    Energy Technology Data Exchange (ETDEWEB)

    Tortorelli, P.F.; Pint, B.A.; Wright, I.G.

    1996-06-01

    Iron aluminides containing greater than about 20-25 @ % Al have oxidation/sulfidation resistance at temperatures well above those at which these alloys have adequate mechanical strength. In addition to alloying modifications for improved creep resistance of wrought material, this strength limitation is being addressed by development of oxide-dispersion- strengthened (ODS) iron aluminides and by evaluation of Fe{sub 3}Al alloy compositions as coatings or claddings on higher-strength, less corrosion-resistant materials. As part of these efforts, the high-temperature corrosion behavior of iron-aluminide weld overlays and ODS alloys is being characterized and compared to previous results for ingot-processed material.

  5. Grey interrelation analysis of alloy elements and steel corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Jinglei; Hou Baorong; Huang Yanliang; Guo Gongyu [Chinese Academy of Sciences, Qingdao (China). Dept. of Oceanology

    2000-07-01

    Mathematical grey interrelation analysis method was used to study the correlation of alloy elements and low steel corrosion in the splash zone. Eighteen kinds of low alloy steels were selected for 350-day experiments in a large marine corrosion environment simulating apparatus. The analysis results showed that the correlation of alloy elements and alloy corrosion rate is in the order: Mn>Si>P>V>Cu>Al>Cr>Mo. The correlation degree was 0.92, 0.89, 0.86, 0.83, 0.82, 0.82, 0.81, 0.77. (orig.)

  6. Fretting corrosion behaviour of ball-and-socket joint on dental implants with different prosthodontic alloys.

    Science.gov (United States)

    Gil, F J; Canedo, R; Padrós, A; Bañeres, M V; Arano, J M

    2003-01-01

    The fretting corrosion of five materials for implant suprastructures (cast-titanium, machined-titanium, gold alloy, silver-palladium alloy and chromium-nickel alloy), was investigated in vitro, the materials being galvanically coupled to a titanium ball-and-socket-joint with tetrafluoroethylene under mechanical load. Various electrochemical parameters (E(corr), i(corr), Evans diagrams, polarization resistance and Tafel slopes) were analyzed. The microstructure of the different dental materials was observed before and after corrosion processes by optical and electron microscopy. It can be observed that the mechanical load produces an important decrease of the corrosion resistance. The cast and machined titanium had the most passive current density at a given potential and chromium-nickel alloy had the most active critical current density values. The high gold content alloys have excellent resistance corrosion, although this decreases when the gold content is lower in the alloy. The palladium alloy had a low critical current density due to the presence of gallium in this composition but a selective dissolution of copper-rich phases was observed through energy dispersive X-ray analysis.

  7. Corrosion Behavior of Additive Manufactured Ti-6Al-4V Alloy in NaCl Solution

    Science.gov (United States)

    Yang, Jingjing; Yang, Huihui; Yu, Hanchen; Wang, Zemin; Zeng, Xiaoyan

    2017-07-01

    The microstructures, potentiodynamic curves, and electrochemical impedance spectroscopy are characterized for Ti-6Al-4V samples produced by selective laser melting (SLM), SLM followed by heat treatment (HT), wire and arc additive manufacturing (WAAM), and traditional rolling to investigate their corrosion behaviors. Results show that the processing technology acts a significant role in controlling the microstructures, which in turn directly determine their corrosion resistance. The order of corrosion resistance of these samples is SLM < WAAM < rolling < SLM+HT. Among these microstructural factors for influencing corrosion resistance, type of constituent phase is the main one, followed by grain size, and the last is morphology. Finally, the application potentials of additive manufactured Ti-6Al-4V alloy are verified in the aspect of corrosion resistance.

  8. Effect of current density on the structure, composition and corrosion resistance of plasma electrolytic oxidation coatings on Mg-Li alloy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhijun [Key Laboratory of Superlight Materials and Surface Technology, College of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Yuan, Yi, E-mail: yi.yuan@hrbeu.edu.cn [Key Laboratory of Superlight Materials and Surface Technology, College of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China); Jing, Xiaoyan [Key Laboratory of Superlight Materials and Surface Technology, College of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin 150001 (China)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer The PEO coatings exhibit tunable characteristics by controlling the current density. Black-Right-Pointing-Pointer The coating formed at 5 A/dm{sup 2} exhibits the highest corrosion resistance. Black-Right-Pointing-Pointer Anti-corrosion properties of PEO coatings are related to coating surface composition. - Abstract: The effect of current density on the oxidation process, morphology, composition and anti-corrosion properties of coatings are elucidated. X-ray photoelectron spectroscopy and X-ray diffraction analysis of coatings show that coatings prepared at different current densities are composed of MgO and {gamma}-Mg{sub 2}SiO{sub 4} and {alpha}-Mg{sub 2}SiO{sub 4} phase. The chemical composition of PEO coatings varies from surface to the interior of the oxide coating. The PEO coatings exhibit tunable thickness, composition ratio, and porosity by controlling the current density, which ultimately affects film morphology and anti-corrosion properties. The superior corrosion resistance of coating obtained at 5 A/dm{sup 2} is attributed to the compactness of the barrier layer and the highest MgO/Mg{sub 2}SiO{sub 4} ratio.

  9. The role of intermetallic phases in the corrosion of magnesium-rare earth alloys

    Energy Technology Data Exchange (ETDEWEB)

    Silva Campos, Maria del Rosario

    2016-07-25

    A new concept to develop a RE based Mg alloy with improved corrosion resistance was followed in the current work. Based on subsequent characterisation steps to eliminate less suitable RE elements the best microstructure for improved corrosion resistance was identified. At first, the corrosion properties of selected RE elements were determined. Based on these results RE elements that have a potential to enhance the corrosion resistance of Mg-RE alloys were selected. Two aspects of RE elements were important for the selection: the electrochemical properties and the solid solubility in Mg. If the solubility limit of RE elements in the Mg matrix is exceeded, they form intermetallic phases with Mg. By performing galvanic coupling measurements the compatibility between Mg matrix and intermetallic phases were estimated. At that point three binary Mg-RE alloys systems remained (Mg-Ce, Mg-La, and Mg-Gd). To evaluate the influence of composition (amount of intermetallic phases) on the corrosion behaviour, four concentrations were cast with 1, 5, 10 and 15 wt. % of RE. Ce and La have a lower solid solubility in Mg matrix generating higher volume fraction of the secondary phases, thus higher dissolution rates in the binary Mg-RE alloys. While Gd with higher solid solubility shows a different behaviour. Additions of up to 10 wt. % Gd resulted in similar behaviour compared to 1 wt. % Gd addition. The most promising results were obtained for the Mg-Gd system with 10 wt. % Gd. Thus, the microstructure of this alloy was further modified by heat treatments to understand the influence of microstructural changes on corrosion behaviour. A ternary element was used to attempt further optimisation of the corrosion performance. Additions of Al, Zn, Ga and Y did not show any improvement in the corrosion resistance of Mg10Gd. This is due to increasing volume fractions of critical more noble phases and the microstructure dominated by eutectic phase formation. Thus galvanic effects became much

  10. 电镀Zn-Ni合金镀层结构及耐蚀性能研究%Study on Microstructure and Corrosion Resistance of Alkaline Zn-Ni Alloy Plating

    Institute of Scientific and Technical Information of China (English)

    刘晓东; 聂朝胤; 赵洋; 聂燕中

    2015-01-01

    在一种Zn‐Ni合金碱性电镀体系中,应用电化学沉积法在304不锈钢表面快速制备了Zn‐Ni合金镀层,采用扫描电子显微镜、X射线衍射仪和电化学工作站,对Zn‐Ni合金镀层及Zn镀层的微观结构及耐蚀性能进行了对比研究.结果表明:所获得的Zn‐Ni合金镀层晶型为γ晶型,镍和锌的质量分数分别为14.37%和85.63%;通过不同电介质溶液模拟不同环境考察Zn‐Ni合金镀层的耐蚀性,在质量分数为5%的NaCl溶液中Zn‐Ni合金镀层的自腐蚀电位相对于Zn镀层正移了245mV,腐蚀推动力比Zn镀层小,其腐蚀电流密度是Zn镀层的0.15倍;在1mol/L的NaOH溶液中,Zn‐Ni合金镀层的自腐蚀电位相对于Zn镀层正移了59mV,其腐蚀电流密度是Zn镀层的0.86倍,所获得的Zn‐Ni合金镀层在中性溶液和碱性溶液中都具有很强的耐蚀性.%A Zn‐Ni alloy coating was quickly prepared on 304 stainless steel surface in an alkaline Zn‐Ni al‐loy plating solution with the electrochemical deposition method .Its microstructure was testified with scan‐ning electron microscopy and X‐ray diffraction graph ,and the corrosion resistance of the Zn‐Ni alloy coat‐ing and the Zn coating was studied and compared with electrochemical workstation .The results showed that the crystal shape of the Zn‐Ni alloy coating obtained in this study was of the γ‐shape and that the con‐tent of nickel and zinc was 14.37% and 85.63% ,respectively .The corrosion resistance of the Zn‐Ni alloy coating was testified in environments with different dielectric solutions .The potential of the Zn‐Ni alloy coating was 245 mV higher than that of the Zn coating in a 5% NaCl solution ,which indicated the driving force on corrosion on the surface of the Zn‐Ni alloy was much less than that of Zn ,and the corrosion cur‐rent density was 0.15 times as much as that of Zn .The potential of the Zn‐Ni alloy coating was 59 m

  11. Electrochemistry Analyzed on Corrosion Resistance of Micro-arc Oxidation and Organic Coating for Mg Alloy%镁合金微弧氧化及后续涂装耐蚀性电化学分析

    Institute of Scientific and Technical Information of China (English)

    李新波; 孙长涛; 郝建民; 王伟

    2009-01-01

    采用IM6e型电化学工作站,对MB8镁合金微弧氧化及封孔涂装后试样进行电化学I/E极化曲线和Tafel斜率分析.结果表明:各种封孔工艺都能不同程度地提高微弧氧化陶瓷层的耐蚀性,其中电泳涂装降低腐蚀电流1个数量级,是良好的封孔工艺:采用水煮+有机树脂多种封孔工艺综合处理降低陶瓷层腐蚀电流2个数量级,耐蚀性最好.%Mg alloy MB8 was surface-modified by micro-arc oxidation (MAO).Several organic coatings were prepared on the micro-arc oxidation coating of the Mg alloy.Electrochemical workstation IM6e was used to measure the electrochemical steady state I/E polarization curves and Tafel slope of the micro-arc oxidation coating in combination with organic coatings.The results show that the organic coatings can increase various degrees of the corrosion resistance of the ceramic layer by micro-arc oxidization of the Mg alloy.Especially,the corrosion resistance of sample which used multi-technics of seal is best.

  12. Effect of Mn on microstructure and corrosion properties of extruded Mg-1%Zn alloy

    Science.gov (United States)

    Zhang, Z. M.; Ma, Y.; Xi, Z. Z.; Xu, C. J.; Lv, Z. L.

    2017-03-01

    The microstructure of the extruded Mg-1Zn alloy doped with different content of manganese was analyzed by optical microscopy, scanning electron microscopy with energy dispersive X-ray spectroscopy and X-ray diffractometry. The mass-loss immersion method and electrochemical test were used to evaluate the corrosion properties. The results show that the microstructure of the extruded Mg-1%Zn-x%Mn (mass fraction, x=0.4, 0.8, 1.2) alloys consists of α-Mg and α-Mn, the grain size of α-Mg decreases with increasing Mn content. Electrochemical corrosion behavior of the alloys is similar. Mn has considerable effect on the corrosion rate, the corrosion process is exacerbated by the galvanic corrosion occurred at interface between α-Mg and α-Mn. The corrosion rate increases as the Mn content increases. Mg-1%Zn-0.4% Mn alloy exhibits the best corrosion resistance between the Mg-1%Zn-x%Mn alloys

  13. Characterization and corrosion behaviour of CoNi alloys obtained by mechanical alloying

    Energy Technology Data Exchange (ETDEWEB)

    Olvera, S. [Instituto Politécnico Nacional, ESIQIE, Departamento de Ingeniería en Metalurgia y Materiales, México, D. F. (Mexico); Universidad Autónoma de Madrid, Facultad de Ciencias, Departamento de Química-Física Aplicada, 28049 Madrid (Spain); Sánchez-Marcos, J. [Universidad Autónoma de Madrid, Facultad de Ciencias, Departamento de Química-Física Aplicada, 28049 Madrid (Spain); Palomares, F.J. [Instituto de Ciencia de Materiales de Madrid, ICMM-CSIC, Cantoblanco, 28049 Madrid (Spain); Salas, E. [Spline Spanish CRG Beamline at the European Synchrotron Radiation Facilities, ESRF, BP 220-38043, Grenoble Cedex (France); Arce, E.M. [Instituto Politécnico Nacional, ESIQIE, Departamento de Ingeniería en Metalurgia y Materiales, México, D. F. (Mexico); Herrasti, P., E-mail: pilar.herrasti@uam.es [Universidad Autónoma de Madrid, Facultad de Ciencias, Departamento de Química-Física Aplicada, 28049 Madrid (Spain)

    2014-07-01

    CoNi alloys including Co{sub 30}Ni{sub 70}, Co{sub 50}Ni{sub 50} and Co{sub 70}Ni{sub 30} were prepared via mechanical alloying using Co and Ni powders. The crystallinity and short-range order were studied using X-ray diffraction and X-ray absorption spectroscopy. The results show that the milling process increases the number of vacancies, especially around the Co atoms, while the milling time decreases the crystalline size and enhances the crystallinity. X-ray photoelectron spectroscopy was used to characterise the chemical composition of the samples surface. The magnetic properties were analysed using zero-field cooling, field cooling and a magnetic hysteresis loops. The magnetic saturation moment is approximately 1.05 μ{sub B}/atom; this value decreases with the mechanical alloying time, and it is proportional to the cobalt concentration. The polarization and impedance curves in different media (NaCl, H{sub 2}SO{sub 4} and NaOH) showed similar corrosion resistance values. The corrosion resistance increased in the order NaCl, H{sub 2}SO{sub 4} and NaOH. A good passivation layer was formed in NaOH due to the cobalt and nickel oxides on the particle surfaces. - Highlights: • Ni{sub x}Co{sub 100-x} alloys were synthesized by mechanical alloying • Milling time decrease size and enhances crystallinity. • Oxygen is not present in a significant percentage in bulk but is detected on the surface. • Magnetic saturation moment is 1.05 mB/atom and decrease with mechanical allowing time • Corrosion resistance is higher in NaOH than in NaCl or HCl solutions.

  14. White primer permits a corrosion-resistant coating of minimum weight

    Science.gov (United States)

    Albrecht, R. H.; Jensen, D. P.; Schnake, P.

    1966-01-01

    White primer for coating 2219 aluminum alloy supplies a base for a top coating of enamel. A formulation of pigments and vehicle results in a primer with high corrosion resistance and minimum film thickness.

  15. Formation and Corrosion Resistance of Micro-Arc Oxidation Coating on Equal-Channel Angular Pressed AZ91D Mg Alloy

    Directory of Open Access Journals (Sweden)

    Aibin Ma

    2016-12-01

    Full Text Available A commercial AZ91D Mg alloy, after bulk grain refinement by various passes of equal-channel angular pressing (ECAP, was selected for micro-arc oxidation (MAO in silicate electrolyte, corrosion testing in 3.5 wt % NaCl solution and morphology analyses. The results showed that a large number of ECAP passes resulted in the homogeneous ultrafine-grained (UFG Mg substrate with broken second-phases. The high-energy defects in the ECAPed samples lowered the anodizing potential of the MAO process, but the partial discharge was severe for those samples below eight passes. Increasing the ECAP pass, the compactness and thickness of the MAO coating first decreased and then increased. Due to the compact coating and the existence of Mg2SiO4, the coated alloy with 16 ECAP passes has a lower corrosion rate and a larger Rt value. Besides the well-known strengthening-toughening effect, grain refinement via multi-pass ECAP can improve surface protection of the MAO coating on the UFG Mg alloy.

  16. Microstructure and corrosion behavior of electrodeposited nano-crystalline nickel coating on AZ91 Mg alloy

    Energy Technology Data Exchange (ETDEWEB)

    Zarebidaki, Arman, E-mail: arman.zare@iauyazd.ac.ir; Mahmoudikohani, Hassan, E-mail: hassanmahmoudi.k@gmail.com; Aboutalebi, Mohammad-Reza

    2014-12-05

    Highlights: • Activation, zincating, and Cu electrodeposition were used as pretreatment processes for electrodeposition of nickel coatings. • Nano-crystalline nickel coatings were successfully electrodeposited onto the AZ91 Mg alloys. • Effect of nickel electrodeposited coating on the corrosion resistance of AZ91 Mg alloy has been studied. - Abstract: In order to enhance the corrosion resistance, nickel coating was electrodeposited onto AZ91 Mg alloy. Activation, zincating, and Cu electrodeposition used as pretreatment processes for better adhesion and corrosion performance of the nickel over layer. The corrosion properties of the AZ91 Mg alloy, nickel electroplated AZ91 Mg alloy, and pure nickel was assessed via polarization and electrochemical impedance spectroscopy (EIS) methods in 3.5 wt% NaCl solution. Moreover, the structure of the coating was investigated by means of X-ray diffraction, whereas specimen’s morphology and elemental composition were analyzed using scanning electron microscope (SEM) equipped with energy dispersive spectrometer (EDS). Measurements revealed that the coating has a nano-crystalline structure with the grain size of 95 nm. Corrosion results showed superior corrosion resistance for the coated AZ91 Mg alloy as the corrosion current density decreased from 2.5 × 10{sup −4} A cm{sup −2}, for the uncoated sample, to 1.5 × 10{sup −5} A cm{sup −2}, for coated specimen and the corrosion potential increased from −1.55 V to −0.98 V (vs. Ag/AgCl) at the same condition.

  17. Application of High Temperature Corrosion-Resistant Materials and Coatings Under Severe Corrosive Environment in Waste-to-Energy Boilers

    Science.gov (United States)

    Kawahara, Yuuzou

    2007-06-01

    Corrosion-resistant materials (CRMs) and coatings are key technologies to increase power generation efficiency and reduce maintenance in waste-to-energy (WTE) plants. Corrosion environment became severe as steam temperatures have increased. The steam condition of more than 400 °C/3.9 MPa became possible in WTE boilers by using highly durable corrosion-resistant coatings, such as thermal spray of Al/80Ni20Cr alloy, HVOF-sprayed NiCrSiB alloy, Alloy 625 weld overlay for waterwall tubes and also superheater tubes. Also, the use of 310S type stainless steels and high Cr-high Mo-Ni base and high Si-Cr-Ni-Fe alloys have progressed because of a better understanding of corrosion mechanisms. Furthermore, high durability coatings using cermet and ceramic materials were applied to high temperature superheaters. This paper describes the major developments and the application of CRMs and coating technologies in the last 30 years in WTE plants, the corrosion mechanisms of alloys, the deterioration mechanisms of spray coating layers, and future subjects for the development of corrosion-resistant materials and coatings.

  18. Hot Corrosion of Nickel-Base Alloys in Biomass-Derived Fuel Simulated Atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Leyens, C.; Pint, B.A.; Wright, I.G.

    1999-02-28

    Biomass fuels are considered to be a promising renewable source of energy. However, impurities present in the fuel may cause corrosion problems with the materials used in the hot sections of gas turbines and only limited data are available so far. As part of the Advanced Turbine Systems Program initiated by the U.S. Department of Energy, the present study provides initial data on the hot corrosion resistance of different nickel-base alloys against sodium sulfate-induced corrosion as a baseline, and against salt compositions simulating biomass-derived fuel deposits. Single crystal nickel-superalloy Rene N5, a cast NiCrAlY alloy, a NiCoCrAlY alloy representing industrially used overlay compositions, and a model {beta}NiAl+Hf alloy were tested in 1h thermal cycles at 950 C with different salt coatings deposited onto the surfaces. Whereas the NiCoCrAlY alloy exhibited reasonable resistance against pure sodium sulfate deposits, the NiCrAiY alloy and Rene N5 were attacked severely. Although considered to be an ideal alumina former in air and oxygen at higher temperatures, {beta}NiAl+Hf also suffered from rapid corrosion attack at 950 C when coated with sodium sulfate. The higher level of potassium present in biomass fuels compared with conventional fuels was addressed by testing a NiCoCrAlY alloy coated with salts of different K/Na atomic ratios. Starting at zero Na, the corrosion rate increased considerably when sodium was added to potassium sulfate. In an intermediate region the corrosion rate was initially insensitive to the K/Na ratio but accelerated when very Na-rich compositions were deposited. The key driver for corrosion of the NiCoCrAlY alloy was sodium sulfate rather than potassium sulfate, and no simple additive or synergistic effect of combining sodium and potassium was found.

  19. Experimental Investigation of the Corrosion Behavior of Friction Stir Welded AZ61A Magnesium Alloy Welds under Salt Spray Corrosion Test and Galvanic Corrosion Test Using Response Surface Methodology

    Directory of Open Access Journals (Sweden)

    A. Dhanapal

    2013-01-01

    Full Text Available Extruded Mg alloy plates of 6 mm thick of AZ61A grade were butt welded using advanced welding process and friction stir welding (FSW processes. The specimens were exposed to salt spray conditions and immersion conditions to characterize their corrosion rates on the effect of pH value, chloride ion concentration, and corrosion time. In addition, an attempt was made to develop an empirical relationship to predict the corrosion rate of FSW welds in salt spray corrosion test and galvanic corrosion test using design of experiments. The corrosion morphology and the pit morphology were analyzed by optical microscopy, and the corrosion products were examined using scanning electron microscope and X-ray diffraction analysis. From this research work, it is found that, in both corrosion tests, the corrosion rate decreases with the increase in pH value, the decrease in chloride ion concentration, and a higher corrosion time. The results show the usage of the magnesium alloy for best environments and suitable applications from the aforementioned conditions. Also, it is found that AZ61A magnesium alloy welds possess low-corrosion rate and higher-corrosion resistance in the galvanic corrosion test than in the salt spray corrosion test.

  20. Effect of temper on seawater corrosion of an aluminum-silicon carbide composite alloy

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Z.; Abdul Aleem, B.J. [King Fahd Univ. of Petroleum and Minerals, Dhahran (Saudi Arabia)

    1996-11-01

    The corrosion behavior of annealed (O), as-fabricated (F), and naturally age-hardened (T4) aluminum alloy Al 6013 with 20 vol% silicon carbide in particulate form was investigated in 3.5 wt% sodium chloride and in Arabian Gulf water. Of the three tempers, T4 showed the lowest corrosion rate (0.04 mpy and 2.61 mpy) in deaerated and aerated NaCl, respectively. The corrosion rate in seawater was slightly higher. Predominant forms of corrosion were pitting and intergranular corrosion. Formation of corrosion chimneys was observed. X-ray diffraction Fourier transform infrared spectroscopy and energy dispersive spectroscopy showed intermetallic formation and the presence of a gelatinous film of aluminum hydroxide of bayrite type. The higher corrosion resistance of the T4 temper resulted from finer and more homogeneously distributed precipitates compared to tempers F and O. In view of the alloy`s good corrosion resistance and outstanding ultimate tensile strength, yield strength and specific modulus, it can be considered a strong competitor to Al 2024, Al 2014, and Al 6061, which are used mainly for structural applications.

  1. Effect of Aging Treatments on the Mechanical and Corrosive Behaviors of Spray-Formed 7075 Alloy

    Science.gov (United States)

    Su, Rui-ming; Qu, Ying-dong; Li, Rong-de

    2014-11-01

    Mechanical properties, microstructure, exfoliation corrosion (EXCO), and intergranular corrosion (IGC) behaviors of the spray-formed 7075 aluminum alloy after T6, T73, retrogression (R), and re-aging (RRA) treatment, respectively, were studied by using tensile tester, transmission electron microscope, and scanning electron microscope. The results show that the T6 process can increase the ultimate tensile strength (UTS) up to 760 MPa, while it decreases the elongation, the EXCO, and the IGC resistance of the alloy. The T73 process can improve elongation, the EXCO, and the IGC resistance of the alloy. The corrosion resistance of the alloy can also be improved by R and RRA processes with retrogression times increase. The tiny precipitated phases distributed homogeneously in the matrix can increase the UTS. The close-connected discrete grain boundary phases (GBP) and the narrow precipitate free zones (PFZ) will lower the elongation, the EXCO, and the IGC resistance of the alloy. Contrarily, the discrete GBP and wide PFZ can improve the elongation, the EXCO, and the IGC resistance of the alloy. The EXCO and the IGC behaviors for the spray-formed 7075 alloy after different aging treatments have been established according to the standards of ASTM G34-2001 (2007) and ASTM G110-1992 (2009).

  2. Preparation of Ce Film on Aluminum Alloy by Brush Plating and Its Corrosion Resistance%铝合金表面电刷镀制备稀土铈转化膜及其耐蚀性

    Institute of Scientific and Technical Information of China (English)

    付大海; 韩忠智; 唐鋆磊; 唐聿明; 左禹

    2011-01-01

    A rare earth Ce film was prepared on LY12 aluminum alloy by brush plating. The obtained Ce film showed layered structure, adhered well on the substrate and showed obviously increased corrosion resistance in NaCl solution. The influences of plating voltage and Ce concentration on the film properties were studied and the best corrosion resistance was obtained under the condition of 7 V and 20 g/L Ce salt concentration. After 480 h of salt fog testing, corrosion resistance of the brush plated surface was estimated to be above 8 grade. The corrosion current density decreased by one order of magnitude and the impedance at low frequency increased by about 30 times in contrast to the original LY12 alloy. Particularly, the strong oxidants are not included in the plating bath, hence the bath is more stable and may be easily recycled. The method may be used to increase corrosion resistance for aluminum alloy equipments with large areas at industrial cases.%利用电刷镀技术在铝合金表面制备了稀土铈转化膜,得到的稀土膜层厚度均匀,呈层状结构,与基体结合良好,在NaCl溶液中具有良好的耐蚀性.研究了刷镀电压和铈盐浓度对膜层耐蚀性的影响,得到在7 V电压和20 g/L铈盐浓度下制备的膜层具有良好耐蚀性能,经过480 h盐雾试验后,其表面耐蚀性评价达到8级以上,镀膜试样与原始LY12铝合金试样相比,腐蚀电流密度降低一个数量级,低频阻抗值则增大约30倍.该铝合金表面稀土转化膜电刷沉积溶液中不合强氧化剂,因此溶液长时间稳定且便于循环利用,可以对铝合金表面进行现场大面积常温刷镀,提高耐蚀性.

  3. Burner Rig Hot Corrosion of Five Ni-Base Alloys Including Mar-M247

    Science.gov (United States)

    Nesbitt, James A.; Helmink, R.; Harris, K.; Erickson, G.

    2000-01-01

    The hot corrosion resistance of four new Ni-base superalloys was compared to that of Mar-M247 by testing in a Mach 0.3 burner rig at 900 C for 300 1-hr cycles. While the Al content was held the same as in the Mar-M247, the Cr and Co levels in the four new alloys were decreased while other strengthening elements (Re, Ta) were increased. Surprisingly, despite their lower Cr and Co contents, the hot corrosion behavior of all four new alloys was superior to that of the Mar-M247 alloy. The Mar-M247 alloy began to lose weight almost immediately whereas the other four alloys appeared to undergo an incubation period of 50-150 1-hr cycles. Examination of the cross-sectional microstructures showed regions of rampant corrosion attack (propagation stage) in all five alloys after 300 1-hr cycles . This rampant corrosion morphology was similar for each of the alloys with Ni and Cr sulfides located in an inner subscale region. The morphology of the attack suggests a classic "Type I", or high temperature, hot corrosion attack.

  4. Is cell viability always directly related to corrosion resistance of stainless steels?

    Science.gov (United States)

    Salahinejad, E; Ghaffari, M; Vashaee, D; Tayebi, L

    2016-05-01

    It has been frequently reported that cell viability on stainless steels is improved by increasing their corrosion resistance. The question that arises is whether human cell viability is always directly related to corrosion resistance in these biostable alloys. In this work, the microstructure and in vitro corrosion behavior of a new class of medical-grade stainless steels were correlated with adult human mesenchymal stem cell viability. The samples were produced by a powder metallurgy route, consisting of mechanical alloying and liquid-phase sintering with a sintering aid of a eutectic Mn-Si alloy at 1050 °C for 30 and 60 min, leading to nanostructures. In accordance with transmission electron microscopic studies, the additive particles for the sintering time of 30 min were not completely melted. Electrochemical impedance spectroscopic experiments suggested the higher corrosion resistance for the sample sintered for 60 min; however, a better cell viability on the surface of the less corrosion-resistant sample was unexpectedly found. This behavior is explained by considering the higher ion release rate of the Mn-Si additive material, as preferred sites to corrosion attack based on scanning electron microscopic observations, which is advantageous to the cells in vitro. In conclusion, cell viability is not always directly related to corrosion resistance in stainless steels. Typically, the introduction of biodegradable and biocompatible phases to biostable alloys, which are conventionally anticipated to be corrosion-resistant, can be advantageous to human cell responses similar to biodegradable metals.

  5. Exfoliation corrosion of 7150 Al alloy with various tempers and its electrochemical impedance spectroscopy in EXCO solution

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.F. [School of Materials Science and Engineering, Central South University, Changsha (China); The Key Laboratory of Nonferrous Metal Materials Science and Engineering, Ministry of Education, Changsha (China); Jia, Z.Q.; Li, C.X. [School of Materials Science and Engineering, Central South University, Changsha (China); Birbilis, N. [Department of Materials Engineering, ARC Centre of Excellence for Design in Light Metals, Monash University, Monash, Victoria (Australia); Cai, C. [School of Chemistry and Chemical Engineering, Ningxia University, Yinchuan (China)

    2009-06-15

    The exfoliation corrosion susceptibility and electrochemical impedance spectroscopy (EIS) of 7150 Al alloys with T6, T73, and RRA (retrogression at 175 C for 3 h) tempers in EXCO solution were investigated. The anodic equilibrium precipitate {eta}(MgZn{sub 2}) is continuous or closely spaced at the grain boundaries in the 7150-T6 Al alloy, resulting in its greatest susceptibility to exfoliation corrosion. The grain boundary {eta} precipitates in the RRA and T73 treated 7150 Al alloys are coarsened and show a clear discontinuous nature; they possess similar exfoliation corrosion sensitivity and their exfoliation corrosion resistance is greatly increased. At the beginning of immersion in EXCO solution, the EIS plot of the 7150 Al alloys is composed of a capacitive arc in the high to medium frequency range and an inductive component in the medium to low frequency range. As immersion time is increased, exfoliation corrosion with different corrosion ratings occurs on the surface of the 7150 Al alloy with various tempers, two capacitive arcs appear in the high to medium and medium to low frequency ranges, respectively. The fitted medium to low frequency capacitance C{sub 2} of 7150-T6 Al alloy, corresponding to the new surface caused by the exfoliation corrosion, is much greater than that of the T73 and RRA treated 7150 Al alloy, which is consistent with the greatest exfoliation corrosion susceptibility of the 7150-T6 Al alloy. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  6. Investigation of the inner corrosion layer formed in pulse electrodeposition coating on Mg-Sr alloy and corresponding degradation behavior.

    Science.gov (United States)

    Shangguan, Yongming; Wan, Peng; Tan, Lili; Fan, Xinmin; Qin, Ling; Yang, Ke

    2016-11-01

    Magnesium-based metals are considered as promising biodegradable orthopedic implant materials due to their potentials of enhancing bone healing and reconstruction, and in vivo absorbable characteristic without second operation for removal. However, the rapid corrosion has limited their clinical applications. Ca-P coating by electrodeposition has been supposed to be effective to control the degradation rate and enhance the bioactivity. In this work, a brushite coating was fabricated on the Mg-Sr alloy by pulse electrodeposition (PED) to evaluate its efficacy for orthopedic application. Interestingly, an inner corrosion layer was observed between the PED coating and the alloy substrate. Meanwhile the results of in vitro immersion and electrochemical tests showed that the corrosion resistance of the coated alloy was undermined in comparison with the uncoated alloy. It was deduced that the existence of this corrosion layer was attributed to the worse corrosion performance of the alloy. The mechanism on formation of the inner corrosion layer and its influence on consequent degradation were analyzed. It can be concluded that the electrodeposition coating should be not suitable for those magnesium alloys with poor corrosion resistance such as the Mg-Sr alloy. More importantly, it should be noted that the process of coating formation combined with the nature of substrate alloy is important to evaluate the efficacy of coating for biodegradable Mg-based implants application.

  7. The resistance of high frequency inductive welded pipe to grooving corrosion in salt water

    Energy Technology Data Exchange (ETDEWEB)

    Duran, C.; Triess, E.; Herbsleb, G.

    1986-09-01

    When exposed to neutral, salt-containing waters, electric resistant welded pipe in carbon and low alloy steels with increased sulfur contents may suffer preferential corrosion attack in the weld area. Because of its appearance, this type of corrosion is called grooving corrosion. The susceptibility to grooving corrosion may be determined and quantitatively described by means of an accelerated potentiostatic exposure test. The importance of type, concentration, and temperature of the electrolytic solution; potential; test duration; and the sulfur content of the steel in the accelerated corrosion test and the susceptibility of steels to grooving corrosion are described. Line pipe in high frequency inductive (HFI) welded carbon and low alloy steels are resistant to grooving corrosion particularly because of their low sulfur content.

  8. Characterization of the Corrosion Behavior of Alloy 22 Regarding its Lifetime Performance as a Potential Nuclear Waste Container Material

    Energy Technology Data Exchange (ETDEWEB)

    Rebak, R B; McCright, D

    2002-06-04

    Alloy 22 (UNS N06022) was proposed for the corrosion resistant outer barrier of a two-layer waste package container for nuclear waste at the potential repository site at Yucca Mountain in Nevada (USA). A testing program is underway to characterize and quantify three main modes of corrosion that may occur at the site. Current results show that the containers would perform well under general corrosion, localized corrosion and environmentally assisted cracking (EAC). For example, the general corrosion rate is expected to be below 100 nm/year and the container is predicted to be outside the range of potential for localized corrosion and environmentally assisted cracking.

  9. Corrosion behavior of plasma electrolytically oxidized gamma titanium aluminide alloy in simulated body fluid.

    Science.gov (United States)

    Lara Rodriguez, L; Sundaram, P A

    2016-09-15

    Plasma electrolytic oxidized (PEO) γTiAl alloy samples were electrochemically characterized by open circuit potential (OCP), cyclic polarization and electrochemical impedance spectroscopy (EIS) to evaluate their corrosion resistance in simulated body fluid (SBF) in order to gauge their potential for biomedical applications. Experimental results through OCP and cyclic polarization studies demonstrated the protective nature and the beneficial effect of the PEO coatings on γTiAl. The PEO surface increased corrosion resistance of these surface modified alloys. EIS data indicated the presence of an underlying compact oxide layer with surface pores represented by two domes in the Nyquist plots. Electrical equivalent circuits to describe the EIS results are proposed.

  10. Corrosion mechanism of micro-arc oxidation treated biocompatible AZ31 magnesium alloy in simulated body fluid

    Directory of Open Access Journals (Sweden)

    Ying Li

    2014-10-01

    Full Text Available The rapid degradation of magnesium (Mg based alloys has prevented their further use in orthopedic trauma fixation and vascular intervention, and therefore it is essential to investigate the corrosion mechanism for improving the corrosion resistance of these alloys. In this work, the effect of applied voltage on the surface morphology and the corrosion behavior of micro-arc oxidation (MAO with different voltages were carried out to obtain biocompatible ceramic coatings on AZ31 Mg alloy. The effects of applied voltage on the surface morphology and the corrosion behavior of MAO samples in the simulated body fluid (SBF were studied systematically. Scanning electron microscope (SEM and X-ray diffractometer (XRD were employed to characterize the morphologies and phase compositions of coating before and after corrosion. The results showed that corrosion resistance of the MAO coating obtained at 250 V was better than the others in SBF. The dense layer of MAO coating and the corrosion precipitation were the key factors for corrosion behavior. The corrosion of precipitation Mg(OH2 and the calcium phosphate (Ca–P minerals on the surface of MAO coatings could enhance their corrosion resistance effectively. In addition, the mechanism of MAO coated Mg alloys was proposed.

  11. Corrosion mechanism of micro-arc oxidation treated biocompatible AZ31 magnesium alloy in simulated body fluid

    Institute of Scientific and Technical Information of China (English)

    Ying Lia; Fang Lu; Honglong Li; Wenjun Zhu; Haobo Pan; Guoxin Tand; Yonghua Lao; Chengyun Ning; Guoxin Ni

    2014-01-01

    The rapid degradation of magnesium (Mg) based alloys has prevented their further use in orthopedic trauma fixation and vascular intervention, and therefore it is essential to investigate the corrosion mechanism for improving the corrosion resistance of these alloys. In this work, the effect of applied voltage on the surface morphology and the corrosion behavior of micro-arc oxidation (MAO) with different voltages were carried out to obtain biocompatible ceramic coatings on AZ31 Mg alloy. The effects of applied voltage on the surface morphology and the corrosion behavior of MAO samples in the simulated body fluid (SBF) were studied systematically. Scanning electron microscope (SEM) and X-ray diffractometer (XRD) were employed to characterize the morphologies and phase compositions of coating before and after corrosion. The results showed that corrosion resistance of the MAO coating obtained at 250 V was better than the others in SBF. The dense layer of MAO coating and the corrosion precipitation were the key factors for corrosion behavior. The corrosion of precipitation Mg(OH)2 and the calcium phosphate (Ca–P) minerals on the surface of MAO coatings could enhance their corrosion resistance effectively. In addition, the mechanism of MAO coated Mg alloys was proposed.

  12. Environmental and alloying effects on corrosion of metals and alloys

    Science.gov (United States)

    Liang, Dong

    2009-12-01

    In the first part of this project, corrosion studies were carried out on 304L stainless steel samples welded with Cr-free consumables, which were developed to minimize the concentration of chromate species in the weld fume. The corrosion properties of Ni-Cu and Ni-Cu-Pd Gas Tungsten Arc (GTA) welds and Shielded Metal Arc (SMA) welds are comparable to those of welds fabricated with SS308L consumable, which is the standard consumable for welding 304L. Although the breakdown potentials of the new welds from both welding processes are lower than that of the SS308L weld, the repassivation potential of these new welds is much higher. Generally, the repassivation potential is a more conservative measure of susceptibility to localized corrosion. Our studies showed that the Ni-Cu and Ni-Cu-Pd welds are more resistant to crevice corrosion than SS308L welds, which is related to the high repassivation potential. Also, addition of Pd improved the corrosion resistance of the new welds, which is consistent with previous studies from button samples and bead-on-plate samples. Other corrosion studies such as creviced and uncreviced long time immersion, atmospheric exposure, and slow strain rate testing suggest that Ni-Cu-Pd welds can be a qualified substitute for SS308 weld. In the second part of this project, efforts are put on the connection between lab and field exposure tests because sometimes the correspondence between lab atmospheric corrosion tests (ASTM B117) and field exposures is poor as a result of differences in the critical conditions controlling chemical and electrochemical reactions on surfaces. Recent studies in atmospheric chemistry revealed the formation of extremely reactive species from interactions between UV light, chloride aerosols above oceans and oxidizing agents such as ozone or peroxide. Atmospheric corrosion of metals can be affected by these species which might be transported long distances in the atmosphere to locations far from oceans. However, these

  13. Corrosion test on Alloy 690 TT in simulated hideout media

    Energy Technology Data Exchange (ETDEWEB)

    Laire, C.; Goffin, C. [Laborelec (Belgium); Mullier, B. [Faculte Polytechnique de Mons (Belgium)

    2002-07-01

    Laborelec has shown the detrimental effect of Cu oxides on Alloy 690 TT in acidic sulfate solutions. Although copper condenser's tubes were replaced by titanium, there are other sources of copper in power plants. Furthermore in spite of improved steam generator (SG) design and better monitoring of secondary water chemistry, deposits formation cannot be fully prevented and impurities such as copper may build up over the years. These impurities are hardly detectable in the SG blow down. During hideout returns for new steam generators, tubed in Alloy 690 TT, compounds like sulfate, silica and organics are mainly found (in the order of one to ten gram). Following these hideout return analyses, influences of main species were studied through stress corrosion cracking tests. The focus is on sulfates, silica, alumina, copper oxides and organic species such as acetate, formate and oxalate. Moreover, the influence of pH in those concentrated solutions-set using ammonia-is also studied. Stress corrosion cracking (SCC) tests are carried out on new SG's Alloy